0% found this document useful (0 votes)
128 views5 pages

KP-9P-1 (KM385BD) Generating Set Technical Data Sheet: Fuzhou GFF Keypower Equipment Co., LTD

1) The document provides technical specifications for KP-9P-1 and KP-10S-1 generating sets produced by Fuzhou GFF Keypower Equipment Co. 2) The generating sets use Laidong diesel engines and Keypower brushless alternators and have a digital auto-start panel for automatic control. 3) Key technical specifications include a standby power of 9.6 kVA, prime power of 8.8 kVA, 3 cylinder engine, and a fuel tank capacity of 55L.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
128 views5 pages

KP-9P-1 (KM385BD) Generating Set Technical Data Sheet: Fuzhou GFF Keypower Equipment Co., LTD

1) The document provides technical specifications for KP-9P-1 and KP-10S-1 generating sets produced by Fuzhou GFF Keypower Equipment Co. 2) The generating sets use Laidong diesel engines and Keypower brushless alternators and have a digital auto-start panel for automatic control. 3) Key technical specifications include a standby power of 9.6 kVA, prime power of 8.8 kVA, 3 cylinder engine, and a fuel tank capacity of 55L.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

KP-9P-1 (KM385BD)

Generating set Technical Data Sheet

FUZHOU GFF KEYPOWER EQUIPMENT CO., LTD


Add: No. 760 Qian Rd. Fuwan Industrial Zone Fuzhou, China 350006
http://www.gff-keypower.com
info@keypower.biz , sales@keypower.biz
Tel:(0086)-591-83568232 Fax:(0086)-591-83568345
Powered by KM385BD
LAIDONG Engine Generating Set

STANDARD SPECIFICATION
General features:
● Composed of Chinese LAIDONG diesel engine and
Keypower brushless alternator
● 12V DC start motor and storage battery
● Brushless, Self-excited, IP23, insulation class H alternator
● 50℃ tropical radiator as standard
● Key start panel control system as standard, digital auto-start
panel is optional
● 55L fuel tank
● Optional open type or silent type
● All generator sets are gone through rigorous testing before
being released to the market place, including 50% load,
75% load, 100% load , 110% load and all protection function
(overspeed stop, high water temperature, low oil pr essure,
battery charging fail, emergency stop)

Genset Main Technical Data


1P2W, 50Hz@1500RPM, 220V (Can be made according to customers’ special requirements)

Genset Specification Engine Specification


KVA
GENSET Cons Alternator
dB(A) Tank Laidong
MODEL 100% Cyl. Gov. Asp. model
ESP PRP @7m (L) engine model
(L/H)

KP-9P-1 9.6 8.8 3.48 68 55 KM385BD 3 M NA DG164C

KP-10S-1 9.6 8.8 3.48 68 55 KM385BD 3 M NA DG164C

1) Available in various voltages


2) To show KEYPOWER Generating Sets Model
KP-9P-1, it is the Prime power 8.8kva generation set.
KP-10S-1, it is the Standby power 9.6kva generation set.
3) ESP=Standby power standby duty, operation under variable load, without overload.
PRP=Prime power continuous duty operation, under variable load, 10% overload permissible 1/12hr.
4) E=Electronic speed governor;
M=Mechanical speed governor
5) Asp=Aspiration;
NA=Naturally Asp;
TC=Turbocharged;
TW=Turbocharged after cooled;
TCA= Turboc harged air-air after cooled
6) Technical data is subject to work test conditions

http://www.gff-keypower.com Page: 2/5 Specifications may change without Notice


Powered by KM385BD
LAIDONG Engine Generating Set

RELIABLE PERFORMANCE

Voltage regulation
Voltage regulation maintained within ±0.5% as follow:
● Power factor Between 0.8~1.0 lag
● From no load to full load, any steady load
● Speed droop variation under 4.5%
Frequency/Speed undulation
● Change load from 0-100%, Frequency/Speed Droop Ratio within 5%.
● Load from 25-100%, any steady load Frequency/Speed undulation within 0.25%

Effect factor of telecom


● TIF( MA MG1-22) better than 50
● THF( BS EN60034) better than 2%

CRITERION

● ISO8528, GB/T2820
● EN12601:2001, EN60034-22:1997, EN60204-1:2006
● ISO9001:2000 Quality Control System

DIMENSIONS AND WEIGHT

Open Type
Overall size (L*W*H)
1250*680*900
Weight: 380kg

Silent Type
Overall size (L*W*H)
1620*750*750
Weight: 480kg

http://www.gff-keypower.com Page: 3/5 Specifications may change without Notice


Powered by KM385BD
LAIDONG Engine Generating Set

ENGINE SPECIFICATION
LAIDONG Diesel Engine
Technical Data

Engine Model KM385BD


Number of Cylinders 3
Cylinder arrangement Vertical in-line
Cycle Four stroke
Aspiration Naturally Aspirated
Bore×Stroke (mm×mm) 85*90
Displacement (Liter) 1.532
Compression Ratio TBD
Prime Power/Speed (kW/rpm) 12/1500RPM
Standby Power/Speed (kW/rpm) 13/1500RPM
Speed Governor Mechanical

Cooling System Water-cooled , 50℃ Tropical Radiator.

Speed Stability (%) ≤5%


Total lubrication system capacity (L) TBD
Coolant capacity (without radiator) (L) TBD
Fuel Consumption at 100% Load (L/H) 3.48
Starter Motor DC12V
Start type Electrical

ALTERNATOR SPECIFICATION

Keypower Alternator (Standard)


Technical Data

Alternator Model DG164C

Exciter type Brushless, Self-excited

Power factor 1.0

Voltage Adjust range ≥5%

Voltage Regulation NL-FL ≤±0.5%

Insulation Grade H

Protection Grade IP23

http://www.gff-keypower.com Page: 4/5 Specifications may change without Notice


Powered by KM385BD
LAIDONG Engine Generating Set

CONTROL SYSTEM

1. Standard: Keypower 6120 AMF Digital Controller


Providing the standard functions as follows:
(Also can be made according to the customers’ special requirements)
*Automatic Start/Stop
*Settings can be adjustable via key buttons on front panel
*3 start attempts failure and Automatic Crank Disconnect
*Parameters display (V/A/Hz/Hour)
*Engine monitoring and protection
*Charge alter nator exciting and Charge alternator fail alarm
*Running hour counting (1) 6120
*Emergency stop pushbutton
*Alarm System: Over speed、High Engine Temperature
Low Oil Pressure、Charge Fail
*Protection System:Over speed、High Engine Temperature、Low Oil
Pressure 、 Emergency Stop. And the other protection function
pre-setting

Digital Auto-start Generator controller integrating digital, intelligent


and network techniques is used for automatic control system of diese l
generator. It can carry out functions including automatic start/stop, data
measure and alarming. Optionally assembled with the ATS, it can carry (2) DSE7320
out auto-switching between the outer power and generating set power.
(AMF)

2. Option: Deepsea DSE7320 AMF Digital Auto Start


3. Option: ComAp AMF25 Digital Auto Start
4. Option: Deepsea DSE3110 Digital Auto Start

(3) AMF25

(4) DSE3110

http://www.gff-keypower.com Page: 5/5 Specifications may change without Notice