TeSys GV2 Motor Circuit Breaker 1-1.6A

1. This document provides specifications for a TeSys GV2 motor circuit breaker that is 3-pole, rated for 1-1.6 amps, uses thermal-magnetic trip technology, and has screw clamp terminals. 2. Key specifications include a rated operational voltage of 690V AC, rated insulation voltage of 690V AC, conventional free air thermal current of 1.6A, and rated impulse withstand voltage of 6kV. 3. Dimensional drawings and mounting information are provided to illustrate the breaker's installation on a DIN rail, panel, or in combination with TeSys contactors using adaptor plates.

Uploaded by

Md Abu Borhan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
70 views9 pages

TeSys GV2 Motor Circuit Breaker 1-1.6A

1. This document provides specifications for a TeSys GV2 motor circuit breaker that is 3-pole, rated for 1-1.6 amps, uses thermal-magnetic trip technology, and has screw clamp terminals. 2. Key specifications include a rated operational voltage of 690V AC, rated insulation voltage of 690V AC, conventional free air thermal current of 1.6A, and rated impulse withstand voltage of 6kV. 3. Dimensional drawings and mounting information are provided to illustrate the breaker's installation on a DIN rail, panel, or in combination with TeSys contactors using adaptor plates.

Uploaded by

Md Abu Borhan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 9

Product datasheet

Specifications

Motor circuit breaker, TeSys GV2,


3P, 1-1.6 A, thermal magnetic,
screw clamp terminals
GV2ME06

Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Main
Range of product TeSys GV2

Range TeSys Deca


TeSys Deca

Device short name GV2ME

Product name TeSys GV2


TeSys Deca

Product or component type Motor circuit breaker

Device application Motor protection

Trip unit technology Thermal-magnetic

Complementary
Poles description 3P

Network type AC

Utilisation category AC-3 conforming to IEC 60947-4-1


Category A conforming to IEC 60947-2

Network frequency 50/60 Hz conforming to IEC 60947-4-1

Fixing mode 35 mm symmetrical DIN rail: clipped


Panel: screwed (with adaptor plate)

Operating position Any position

Motor power kW 0.37 kW at 400/415 V AC 50/60 Hz


0.37 kW at 500 V AC 50/60 Hz
0.75 kW at 690 V AC 50/60 Hz
0.55 kW at 400/415 V AC 50/60 Hz
0.55 kW at 500 V AC 50/60 Hz
0.75 kW at 500 V AC 50/60 Hz
1.1 kW at 690 V AC 50/60 Hz

Breaking capacity 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2


100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2

[Ics] rated service short-circuit 100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
breaking capacity 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2

Control type Push-button

[In] rated current 1.6 A

Thermal protection adjustment 1…1.6 A


range

Sep 1, 2022 1
Magnetic tripping current 22.5 A

[Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2

[Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2

[Ith] conventional free air 1.6 A conforming to IEC 60947-4-1


thermal current

[Uimp] rated impulse withstand 6 kV conforming to IEC 60947-2


voltage

Power dissipation per pole 2.5 W

Mechanical durability 100000 cycles

Electrical durability 100000 cycles for AC-3 at 415 V


at 415 V

Maximum operating rate 25 cyc/h

Rated duty Continuous conforming to IEC 60947-4-1

Tightening torque 1.7 N.m on screw clamp terminals

Mechanical robustness Shocks: 30 Gn conforming to IEC 60068-2-27


Vibrations: 5 Gn, 5...150 Hz conforming to IEC 60068-2-6

Phase failure sensitivity Yes conforming to IEC 60947-4-1

Height 89 mm

Width 45 mm

Depth 78.5 mm

Net weight 0.26 kg

Colour Dark grey

Suitability for isolation Yes conforming to IEC 60947-1 § 7-1-6

Environment
Standards EN/IEC 60947-2
EN/IEC 60947-4-1

Product certifications CCC


UL
CSA
EAC
ATEX
BV
LROS (Lloyds register of shipping)
UKCA
DNV-GL
RINA

Climatic withstand conforming to IACS E10

IK degree of protection IK04

IP degree of protection IP20 conforming to IEC 60529

Ambient air temperature for -40…80 °C


storage

Fire resistance 960 °C conforming to IEC 60695-2-11

Operating altitude 2000 m

Ambient air temperature for -20…60 °C


operation

Packing Units
Unit Type of Package 1 PCE

Number of Units in Package 1 1

Package 1 Weight 253.0 g

Package 1 Height 4.5 cm

2
Sep 1, 2022
Package 1 width 8.5 cm

Package 1 Length 9.0 cm

Unit Type of Package 2 S02

Number of Units in Package 2 24

Package 2 Weight 6.317 kg

Package 2 Height 15.0 cm

Package 2 width 30.0 cm

Package 2 Length 40.0 cm

Unit Type of Package 3 P06

Number of Units in Package 3 384

Package 3 Weight 109.072 kg

Package 3 Height 75.0 cm

Package 3 width 80.0 cm

Package 3 Length 60.0 cm

Offer Sustainability
Sustainable offer status Green Premium product

REACh Regulation REACh Declaration

EU RoHS Directive Compliant


EU RoHS Declaration

Mercury free Yes

RoHS exemption information Yes

China RoHS Regulation China RoHS declaration


Product out of China RoHS scope. Substance declaration for your information

Environmental Disclosure Product Environmental Profile

Circularity Profile End of Life Information

WEEE The product must be disposed on European Union markets following specific waste collection and
never end up in rubbish bins

Contractual warranty
Warranty 18 months

Sep 1, 2022 3
Product datasheet GV2ME06
Performance Curves

Thermal-Magnetic Tripping Curves for GV2ME and GV2P


Average Operating Times at 20 °C Related to Multiples of the Setting Current

1 3 poles from cold state


2 2 poles from cold state
3 3 poles from hot state

Current Limitation on Short-Circuit for GV2ME and GV2P (3-Phase 400/415 V))
Dynamic Stress
I peak = f (prospective Isc) at 1.05 Ue = 435 V

4
Sep 1, 2022
1 Maximum peak current
2 24-32 A
3 20-25 A
4 17-23 A
5 13-18 A
6 9-14 A
7 6-10 A
8 4-6.3 A
9 2.5-4 A
10 1.6-2.5 A
11 1-1.6 A
12 Limit of rated ultimate breaking capacity on short-circuit of GV2ME (14, 18, 23, and 25 A ratings).

Thermal Limit on Short-Circuit for GV2ME


2
Thermal Limit in kA s in the Magnetic Operating Zone
2
Sum of I dt = f (prospective Isc) at 1.05 Ue = 435 V

Sep 1, 2022 5
1 24-32 A
2 20-25 A
3 17-23 A
4 13-18 A
5 9-14 A
6 6-10 A
7 4-6.3 A
8 2.5-4 A
9 1.6-2.5 A
10 1-1.6 A

6
Sep 1, 2022
Product datasheet GV2ME06
Dimensions Drawings

Dimension
GV2ME

(1) Maximum
X1 Electrical clearance = 40 mm for Ue ≤ 690 V

GV2ME●● 89

GV2ME●●3 101

Mounting
GV2ME
On 35 mm rail

c = 78.5 on AM1 DP200 (35 x 7.5)


c = 86 on AM1 DE200, ED200 (35 x 15)
On panel with adapter plate GV2AF02

On pre-slotted plate AM1 PA

On rails DZ5 MB201

GV2AF01
Combination GV2ME + TeSys k contactor

GV2AF3

Sep 1, 2022 7
Combination GV2ME + TeSys d contactor

GV2ME + LC1D09…D18 LC1D25 and D32

b 176.4 186.8

c1 94.1 100.4

c 99.6 105.9

GV2AF4 + LAD311
Combination GV2ME + TeSys d contactor

GV2ME + LC1D09…D18 LC1D25 and D32

b 176.4 186.8

c1 103.1 136.4

c 135.6 141.9

d1 107 107

d 112.5 112.5

GV2ME + GV1L3 (Current Limiter)

X1 = 10 mm for Ue = 230 V or 30 mm for 230 V < Ue ≤ 690 V

8
Sep 1, 2022
Product datasheet GV2ME06
Connections and Schema

GV2ME•• and GV2RT

Connection of Undervoltage Trip for Dangerous Machines (Conforming to INRS) on GV2ME Only

Sep 1, 2022 9