Hicatalog Full

IESNA (Illuminating engineering Society of North America) provides guidelines for your use. Standard footcandle (fc) ratings break out "tasks" into six basic levels of lighting. Lighting the "Industrial" environment is not always an easy task. The specifier must consider many elements which work to impact the amount of light reaching a work surface as well as its quality.
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
757 views164 pages

Hicatalog Full

IESNA (Illuminating engineering Society of North America) provides guidelines for your use. Standard footcandle (fc) ratings break out "tasks" into six basic levels of lighting. Lighting the "Industrial" environment is not always an easy task. The specifier must consider many elements which work to impact the amount of light reaching a work surface as well as its quality.
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 164

Hubbell Industrial Lighting Complete Product & Reference Guide

TRIBAY SUPERWATT FIXTURES IN MACK TRUCK ASSEMBLY AREA

TRIBAY FIXTURES IN US STEEL

SUPERBAY FIXTURES IN WEST VIRGINIA LUMBER YARD.

SUPERWATT FIXTURES IN RR DONNELLY PRINTING PLANT

NO ONE KNOWS HOW TO LIGHT CRITICAL WORK AREAS BETTER.


Since Harvey Hubbells invention of the electrical wall plug and socket over 100 years ago, Hubbell has been engineering tough, hardworking products designed for the real world. Products ready to survive in high temperatures, wet and dirty environments, and where a variety of lighting requirements exist, from general warehousing to assembling small, precise electrical components. Critical items can be gathered into three areas: quality, quantity and life Building on this expertise, Hubbell Lighting has pioneered many innovations in lighting optics and ballast/lamp systems designed to save your operation both energy and maintenance dollars over the life of their operation. For over 40 years, our industrial luminaires have lit vast warehouses, complex machinery, large mass merchandisers, and a wide range of process and assembly industries. SO, HOW MUCH LIGHT DO I NEED? Standard footcandle (fc) ratings have been set by the IESNA (Illuminating Engineering Society of North America) and provide guidelines for your use. The chart on page 8 breaks out tasks into six basic levels of lighting, from public cycle costs of your system which includes energy and maintenance/operation issues. So, with upwards of 25 possible items to consider, from mounting height to IES lumen standards, yes, it can sometimes be a complex assignment. However, by looking at the task, quality and quantity of light, and expectations on maintenance costs, the process of system selection can be streamlined.

What makes an industrial workplace different


Lighting the Industrial environment is not always an easy task. Because of a wide variety of operations and tasks, the specifier must consider many elements which work to impact the amount of light reaching a work surface as well as its quality. Additionally, in the overall cost of the system are maintenance/service issues which are determined by choice of ballast, optic, lamp, and the impact of temperature, accumulative dirt and moisture levels within your workplace environment.

spaces to that of low contrast, small-sized parts assembly operations. By reviewing this chart youll gain a reference point for your specific need. Additionally, IES lists average lumen and footcandle levels. The charts on pages 8 and 9 are general guidelines for target-maintained illuminance values.

Patented Expertise. Hubbell holds over 30 important patents that let you increase workplace efficiency and lower your maintenance costs. PATENT
TITLE START, HOT RESTART AND OPERATING LAMP CIRCUIT FAILING LAMP MONITORING AND DEACTIVATING CIRCUIT HIGH WATTAGE HID LAMP CIRCUIT END-OF-LIFE LAMP STARTER DISABLING CIRCUIT LAMP STARTING CIRCUIT CONTROLLED-CURRENT LAMP STARTING CIRCUIT STEP-DIMMING MAGNETIC REGULATOR FOR DISCHARGE LAMP IMPROVED LOW LOSS BALLAST SYSTEM LAMP STARTING CIRCUIT LAMP STARTING CIRCUIT APPARATUS FOR DIMMING ... OF ELECTRO-REG SYSTEM LAMP DRIVEN VOLTAGE TRANSFORMATION AND BALLAST SYSTEM REDUCED DUTY CYCLE H.I.D. LAMP IGNITOR EMERGENCY LIGHTING FOR HIGH INTENSITY DISCHARGE LAMPS MULTI-VOLTAGE BALLAST & DIMMING CIRCUITS FOR A LAMP DRIVEN VOLTAGE TRANSFORMATION & BALLASTING SYSTEM INTEGRATED FOLD-UP REFLECTOR BRACKETS HIGH-INTENSITY DISCHARGE IGNITOR FOR USE WITH HIGH-PRESSURE SODIUM LAMPS AND BALLASTS PATENT NUMBER 4,763,044 4,810,936 4,890,041 5,019,751 5,047,694 5,210,471 5,216,333 5,309,065 5,321,338 5,594,308 5,663,612 5,825,139 5,886,481 5,955,843 5,962,988 6,024,470 6,091,208 TITLE LIGHTING CONTROL SYSTEM FOR DISCHARGE LAMPS LOW COST HIGHBAY EXTERNALLY MOUNTABLE DISCHARGE LAMP IGNITION CIRCUITRY INCORPORATING A VISUAL DIAGNOSTIC INDICATOR HOUSING FOR LUMINAIRE IMPROVED, LOW LOSS, ELECTRONIC BALLAST HIGH INTENSITY DISCHARGE BALLAST POWER LEVEL CONVERSION METHOD IES TYPE 5 DISTRIBUTION, OPTICAL ASSEMBLY, VERTICAL BASE-UP LAMP CRANE LIGHT FLUORESCENT HIGH BAY DESIGN TEXTURED DIFFUSE SURFACE APPLICATION TO GLASS REFLECTOR HIGH-INTENSITY DISCHARGE IGNITOR PULSE DETECTOR REGULATING BALLAST FOR H.I.D. LAMPS REMOTE DISCHARGE LAMP IGNITION CIRCUITRY UNIVERSAL SODIUM IGNITOR DISABLE CIRCUIT LAMP IGNITOR CIRCUIT W/ NOVEL PULSE CESSATION FUNCTION MULTIPLE BALLAST AND LAMP CONTROL SYSTEM NUMBER 6,114,816 6,123,435 6,127,782 D433,520 6,166,492 6,320,328 6,338,564 6,388,392 D465,869 6,494,596 6,534,988 6,545,429 6,597,128 6,642,673 6,724,155 6,731,080

HOW TO USE THIS CATALOG


You have in your hands a complete reference guide on how to light industrial and other large size spaces. Highlights of what is inside are:

Recommended Illuminance Values Complete product pages to cover all industrial applications Information on EPAct Information on unique Hubbell Industrial Electronic Ballasts Why use HID Good three dimensional lighting products Dimming systems Flexible Wiring systems Information on Extreme environment products Information on Ingress Protection (IP) Information on Hazardous location Products Quick Estimators to help determine the number of fixtures required HID Ballast electrical data Completely new HID ballast troubleshooting guide Thumbnail photometrics

Backing up this guide is your local Hubbell Lighting Representative and our field sales team. As always, innovation is a constant process at Hubbell Industrial lighting and specifications may change over time.

CONTENTS
INTRODUCTION
Recommended illuminance values . . . . . . . . . . . . . . 6 Pictorial index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Recommended illuminance values . . . . . . . . . . . . . 11 Energy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Electronic ballasts: EL Series steel housing . . . . . 13 Tribay introduction . . . . . . . . . . . . . . . . . . . . . . . . . 14

HID ACRYLIC OPTICS


Electronic SWX/LWX . . . . . . . . . . . . . . . . . . . . . . . . 38 Electronic V-Spec . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Electronic 16" EL-PA2 . . . . . . . . . . . . . . . . . . . . . . . 40 Electronic 22" EL-WA22 . . . . . . . . . . . . . . . . . . . . . 41 Electronic 22" EL-WW22 . . . . . . . . . . . . . . . . . . . . . 41 Electronic 25" EL-WA25 . . . . . . . . . . . . . . . . . . . . . 42 Electronic Superwatt EL-CH-SW . . . . . . . . . . . . . . 43

ADDED PERFORMANCE PRODUCTS


EPAct 2005 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76 Electronic E-Reg . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 EL Series electronic ballasts . . . . . . . . . . . . . . . . . 78 Electro-Reg ballast system . . . . . . . . . . . . . . . . . . 81

V-Spec . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 HID vs. Fluorescent . . . . . . . . . . . . . . . . . . . . . . . . . 86 PulseSmart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88 Horizontal/vertical/3d lighting . . . . . . . . . . . . . . . . 90 Dimming/Wiring systems . . . . . . . . . . . . . . . . . . . . 91 Modular Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97

Superbay introduction . . . . . . . . . . . . . . . . . . . . . . . 15 Superbay ballast housings . . . . . . . . . . . . . . . . . . . 16 Superbay optics . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Decorative Highbay HDH . . . . . . . . . . . . . . . . . . . . . 44 Tribay 22" WA22 . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

Tribay 22" WW22 . . . . . . . . . . . . . . . . . . . . . . . . . . 45

HID HIGHBAYS
Electronic 14" EL-BI . . . . . . . . . . . . . . . . . . . . . . . . 18 Electronic enclosed & gasketed EL-EG . . . . . . . . . 19 Electronic 19" with uplight EL-SU . . . . . . . . . . . . . 20 Electronic 19" downlight only EL-SD . . . . . . . . . . . 20 Electronic 19" aislelighter EL-AL . . . . . . . . . . . . . . 20 Tribay CHEU/CHOU . . . . . . . . . . . . . . . . . . . . . . . . . 21

Tribay 25" WA25 . . . . . . . . . . . . . . . . . . . . . . . . . . . 46

Tribay Superwatt CH-SW . . . . . . . . . . . . . . . . . . . 47


EXTREME ENVIRONMENTAL LIGHTING


Extreme Environment intro . . . . . . . . . . . . . . . . . . . 99 Ingress Protection . . . . . . . . . . . . . . . . . . . . . . . . . 100 Hazardous NEC . . . . . . . . . . . . . . . . . . . . . . . . . . . 101

Superbay 16" BL-PA2 . . . . . . . . . . . . . . . . . . . . . . . 48 Superbay 22" BL-WA22 . . . . . . . . . . . . . . . . . . . . . 49 Superbay 22" BL-WW22 . . . . . . . . . . . . . . . . . . . . . 49 Superbay 25" BL-WA25 . . . . . . . . . . . . . . . . . . . . . 50 Superbay Superwatt CH-SW . . . . . . . . . . . . . . . . . 51

CLASS I, DIVISION 1
HLE Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103 HLEZ Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106 HL-HFX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110

Tribay CHEU60/CHOU60 . . . . . . . . . . . . . . . . . . . . . 22

Superwatt SWD/SWW HID . . . . . . . . . . . . . . . . . . . 52

Superbay 14" BL-BI . . . . . . . . . . . . . . . . . . . . . . . . 23 Superbay enclosed & gasketed BL-EG . . . . . . . . . . 24 Superbay 23" BL-OU60 . . . . . . . . . . . . . . . . . . . . . . 25 Superbay 19" with uplight BL-SU . . . . . . . . . . . . . 26 Superbay 19" downlight only BL-SD . . . . . . . . . . . 26 Superbay 19" aislelighter BL-AL . . . . . . . . . . . . . . 26 Utility Highbay BL400HB/BL400HBQ . . . . . . . . . . . . 27

Lightwatt LW HID . . . . . . . . . . . . . . . . . . . . . . . . . . 53

COMPACT FLUORESCENT
Decorative CFL HDF . . . . . . . . . . . . . . . . . . . . . . . . . 54 Superwatt CFL . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55

CLASS I, DIVISION 2
Magnuliter MVH Series . . . . . . . . . . . . . . . . . . . . 111

Lightwatt CFL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56

Perimaliter PGM2 . . . . . . . . . . . . . . . . . . . . . . . . . . 112 Kemlux III KH Series . . . . . . . . . . . . . . . . . . . . . . 113

WORKLIGHT HID LOWBAYS


Electronic 23" EL-LB1 . . . . . . . . . . . . . . . . . . . . . . . 28 Electronic 29" EL-LM . . . . . . . . . . . . . . . . . . . . . . . 29 Tribay CH-LM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

Kemlux II KH Series . . . . . . . . . . . . . . . . . . . . . . . 117

Utility Worklight BL400WL/BL400LEX . . . . . . . . . . . 57

HLMB Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121 Mariner Floodlight . . . . . . . . . . . . . . . . . . . . . . . . 124

MISCELLANEOUS
Unit Pack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 Packaging options . . . . . . . . . . . . . . . . . . . . . . . . . . 59 BL Flush Mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 Options/Accessories . . . . . . . . . . . . . . . . . . . . . . . . 60 Tribay Remote Series CH-RO . . . . . . . . . . . . . . . . . 71

Hazardous Strobes . . . . . . . . . . . . . . . . . . . . . . . . 126 Lightwatt LW2 . . . . . . . . . . . . . . . . . . . . . . . . . . . 127

Superbay 23" BL-LB1 . . . . . . . . . . . . . . . . . . . . . . . 31 Superbay 29" BL-LM . . . . . . . . . . . . . . . . . . . . . . . . 32 Microlux 23" . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

Vaportite V Series . . . . . . . . . . . . . . . . . . . . . . . . . 128

SEALED
Kemlux III KS Series . . . . . . . . . . . . . . . . . . . . . . . 130

Utility Lowbay BL400LB/BL400LBQ . . . . . . . . . . . . 34

Superbay Remote Series BL-RO . . . . . . . . . . . . . . . 72

Kemlux II KS Series . . . . . . . . . . . . . . . . . . . . . . . 133

HID GLASS OPTICS


Electronic 16" EL-HGO16/EL-HGE16 . . . . . . . . . . . . 35 Electronic 22" EL-HGO22/EL-HGE22 . . . . . . . . . . . . 35 Tribay HGO16/HGE16 . . . . . . . . . . . . . . . . . . . . . . . 36

Light Bat G2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73

Vaportite NV Series . . . . . . . . . . . . . . . . . . . . . . . 136

BYMB Series Obstruction Lights . . . . . . . . . . . . . . 137 Hazardous Photocell . . . . . . . . . . . . . . . . . . . . . . . 138 Pendant Hangers . . . . . . . . . . . . . . . . . . . . . . . . . . 138

Tribay HGO22/HGE22 . . . . . . . . . . . . . . . . . . . . . . . 36

Superbay 16" BL-HGO16/BL-HGE16 . . . . . . . . . . . . 37 Superbay 22" BL-HGO22/BL-HGE22 . . . . . . . . . . . . 37

TECHNICAL INFORMATION
Quick Estimators . . . . . . . . . . . . . . . . . . . . . . . . . . 140 HID Ballast electrical data MH . . . . . . . . . . . . . . . 146 HID Ballast electrical data HPS . . . . . . . . . . . . . . 148 HID Ballast electrical data MV . . . . . . . . . . . . . . . 149 Troubleshooting guide . . . . . . . . . . . . . . . . . . . . . . 150 Photometrics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 158

RECOMMENDED ILLUMINANCE VALUES


(TARGET MAINTAINED) FOR INDUSTRIAL LIGHTING DESIGN
Values for industrial areas/activities - interior
AREA / ACTIVITY LUX (FC)1

AIRCRAFT MAINTENANCE Docking all activities required to dock Cleaning, prime painting, final painting exterior Modifications or repairs to systems Ramp lighting Predocking activities Preparing to dedock Specialty shops (instruments, electrical, plastics, upholstery, parts inspection) Systems operations and functional checks requiring activation of aircraft power systems to perform System repairs after operations and close up preparation System restoration or new system component installation AIRCRAFT MANUFACTURING FABRICATION (preparation for assembly) Drilling, riveting, screw fastening Layout and template work, shaping and smoothing small parts for fuselage, wing sections, cowling, etc. Scribing Plating AIRCRAFT MANUFACTURING GENERAL Rough easy seeing Rough difficult seeing Medium Fine Extra fine First manufacturing operations (sheet metal) (see Sheet Metal Works) Flight test and delivery area BREWERIES Brew house Boiling and keg washing Filling (bottles, cans, kegs) ELECTRICAL EQUIPMENT MANUFACTURING Impregnating Insulating: coil winding FLOUR MILLS Rolling, sifting, purifying Packing Product control Cleaning screens, man lifts, aisleways, walkways, bin checking FOUNDRIES Annealing (furnaces) Cleaning Core making: fine Core making: medium Grinding and chipping Molding: medium Molding: large Pouring Sorting Cupola Shakeout GARAGES SERVICE Repairs Active traffic areas Write-up
Information provided by IES from the Recommended Practice for Lighting Industrial Facilities, ANSI/IESNA RP-7-01

750 (75) 750 (75) 750 (75) 30 (3) 750 (75) 300 (30) 1500 (150) 750 (75) 750 (75) 750 (75) 750 (75) 750 (75) 1500 (150) 300 (30) 300 (30) 750 (75) 750 (75) 1500 (150) 3000 (300) 30 (3) 300 (30) 300 (30) 300 (30) 300 (30) 750 (75) 750 (75) 300 (30) 1500 (150) 300 (30) 300 (30) 300 (30) 1500 (150) 750 (75) 1500 (150) 1500 (150) 750 (75) 750 (75) 750 (75) 150 (15) 300 (30) 750 (75) 150 (15) 300 (30)

AREA / ACTIVITY

LUX (FC)1

MEAT PACKING Slaughtering Cleaning, cutting, cooking, grinding, canning, packing PAINT MANUFACTURING Processing Mix comparison POULTRY INDUSTRY Brooding, production, and laying houses Feeding, inspection, cleaning Charts and records Thermometers Hatcheries General area and loading platform Inside incubators Dubbing station Sexing Fowl processing plant General (including killing and unloading area) Government inspection station and grading stations Unloading and killing area PRINT INDUSTRIES Printing plants Color inspection and appraisal Machine composition Composing room Presses Imposing stones Proofreading SHEET METAL WORKS Miscellaneous machines, ordinary bench work Presses, shears, stamps, spinning, medium bench work Punches Tin plate inspection, galvanized Scribing TEXTILE MILLS Staple fiber preparation Stock dyeing, tinting Sorting and grading (wool and cotton) Yarn manufacturing Opening and picking (chute feed) Carding (non-woven web formation) Drawing (gilling, pin drafting) Combing Roving (slubbing, fly frame) Spinning (cap spinning, twisting, texturing) Yarn preparation Winding, quilling, twisting Warping (beaming, sizing) Warp tie-in or drawing-in (automatic)

300 (30) 300 (30) 300 (30) 1500 (150)

150 (15) 300 (30) 300 (30) 150 (15) 300 (30) 1500 (150) 7500 (750) 750 (75) 750 (75) 750 (75)

1500 (150) 750 (75) 750 (75) 750 (75) 1500 (150) 1500 (150) 750 (75) 750 (75) 750 (75) 1500 (150) 1500 (150)

300 (30) 750 (75)2 300 (30) 300 (30)3 300 (30) 300 (30)3 750 (75) 750 (75) 750 (75) 1500 (150) 2 750 (75)

1 Industry representatives have established this table of single illuminance values. Illuminance values for specific operations can also be determined by using illuminance values for similar tasks and activities. 2 Supplementary lighting should be provided in this space to product the higher levels required for specific seeing tasks involved. 3 Additional lighting needs to be provided for maintenance only.

HID HIGHBAY
Electronic 14" Aluminum EL-BI page 18 Electronic Enclosed & Gasketed EL-EG page 19 Electronic 19" Aluminum EL-SU page 20 Electronic 19" Aluminum EL-SD page 20 Electronic 19" Aluminum EL-AL page 20 Tribay CHEU/CHOU page 21

Tribay CHEU60/CHOU60 page 22

Superbay 14" Aluminum BL-BI page 23

Superbay Sealed & Gasketed BL-EG page 24

Superbay 23" Aluminum BL-OU60 page 25

Superbay 19" Aluminum BL-SU page 26

Superbay 19" Aluminum BL-SD page 26

HID LOWBAY

Superbay 19" Aluminum BL-AL page 26

Utility Highbay BL400HB/BL400HBQ page 27

Electronic 23" Lowbay EL-LB1 page 28

Electronic 29" Lowbay EL-LM page 29

Tribay CH-LM page 30

Superbay 23" Lowbay BL-LB1 page 31

HID GLASS

Superbay 29" Lowbay BL-LM page 32

Microlux 23" Lowbay page 33

Utility Lowbay BL400LB/BL400LBQ page 34

Electronic 16" Glass EL-HGO16/HGE16 page 35

Electronic 22" Glass EL-HGO22/HGE22 page 35

Tribay HGO16/HGE16 page 36

HID ACRYLIC

Tribay HGO22/HGE22 page 36

Superbay 16" Glass BL-HGO16/BL-HGE16 page 37

Superbay 22" Glass BL-HGO22/BL-HGE22 page 37

Electronic SWX/LWX page 38

Electronic V-SPEC page 39

Electronic 16" Acrylic EL-PA2 page 40

Electronic 22" Acrylic EL-WA22 page 41

Electronic 22" Acrylic EL-WW22 page 41

Electronic 25" Acrylic EL-WA25 page 42

Electronic Superwatt Optics EL-CH-SW page 43

Decorative Highbay HDH page 44

Tribay 22" Acrylic WA22 page 45

Tribay 22" Acrylic WW22 page 45

Tribay 25" Acrylic WA25 page 46

Tribay Superwatt CH-SW page 47

Superbay 16" Acrylic BL-PA2 page 48

Superbay 22" Acrylic BL-WA22 page 49

Superbay 22" Acrylic BL-WW22 page 49

Superbay 25" Acrylic BL-WA25 page 50

Superbay Superwatt Optics CH-SW page 51

Superwatt SWD/SWW HID page 52

Lightwatt LW HID page 53

COMPACT FLUORESCENT
Decorative CFL HDF page 54 Superwatt CFL page 55

WORKLIGHT

Lightwatt CFL page 56

Utility Worklight BL400WL/BL400LEX page 57

PACKAGING

OPTIONS/ ACCESSORIES
Options/ Accessories page 60-70

Unit Pack page 58

BL Packaging page 59

BL Flush Mount page 59

Tribay Remote CH-RO page 71

Superbay Remote BL-RO page 72

Light Bat G2 page 73-74

Switch Level Dimming page 91-96

Modular Wiring page 97-98

CLASS I, DIVISION 1

HLE Series page 103

HLEZ Series page 106

HL-HFX Series page 110

CLASS I, DIVISION 2

Magnuliter MVH page 111

Perimaliter PGM2 page 112

Kemlux III KH Series page 113

Kemlux II KH Series page 117

HLMB Series page 121

Mariner Floodlight page 124-125

Hazardous Strobes page 126

Lightwatt LW2 page 127

Vaportite V Series page 128

SEALED

Kemlux III KS Series page 130

Kemlux II KS Series page 133

Vaportite NV Series page 136

MISCELLANEOUS

BYMB Series page 137

Hazardous Photocell page 138

Pendant Hangers page 138-139

10

WHAT MAKES LIGHTING AN INDUSTRIAL WORKPLACE DIFFERENT

Determination of Illuminance Categories


ORIENTATION AND SIMPLE VISUAL TASKS

VISUAL PERFORMANCE IS LARGELY UNIMPORTANT


These tasks are found in public spaces where reading and visual inspection are only occasionally performed. Higher levels are recommended for tasks where visual performance is occasionally important.

Public spaces

30 lx (3 fc)

Simple orientation for short visits

30 lx (3 fc)

Working spaces where simple visual tasks are performed

30 lx (3 fc)

COMMON VISUAL TASKS

VISUAL PERFORMANCE IS IMPORTANT


These tasks are found in commercial, industrial and residential applications. Recommended illuminance levels differ because of the characteristics of the visual task being illuminated. Higher levels are recommended for tasks with critical elements of low contrast or small size.

Performance of visual tasks of high contrast and large size

300 lx (30 fc)

Performance of visual tasks of high contrast and small size, or visual tasks of low contrast and large size

500 lx (50 fc)

Performance of visual tasks of low contrast and small size

1000 lx (100 fc)

Information provided by IES from the Recommended Practice for Lighting Industrial Facilities, ANSI/IESNA RP-7-01

11

energy savings
V-Spec
True 3D vertical surface lighting with the efficiency of an electronic ballast and superior color rendering, all from Hubbell Lighting. Perfect for Retail settings. See pages 84-85 for more detail. Better lumen maintenance allows less fixtures Delivers 70% more mean lumens per watt than standard MH Multi wattage 250,300,320,350, or 400 watt MH or CMH Operates on 208-277V Up to 55 ambient temperature

EL Series
Perfect all around option for those applications that require electronic ballasts. Wide variety of optics available. Features Hubbells Electronic E-Reg. Can dim to 50% of full light with simple 0-10V controls. See pages 77-80 for more detail. Glass, Acrylic and Spun Aluminum optic options available 320 350 and 400 watt available Intellivolt 200 277V Integral 120V quartz tap and relay 0-10V dimming down to 50% of full light output

Electronic Superwatt & Lightwatt


Industry leading optical performance with fully controllable electronic ballast. 320, 350 and 400 watt MH Wet or damp location Up to 55 ambient temperatures Industry leading optics for efficient horizontal and vertical illumination

Electro-Reg
The Electro-Reg system provides long lamp life, more consistent output through out life and better color control than metal halide operated on standard CWA ballasts. See page 83 for more detail. Double lamp life Hot Re-Strike in 2-4 minutes Better color and output stability Operates down to -40C

Pulse Smart
Hubbell Lighting does it again. Although a standard MH fixture is good, and a pulse start system is more efficient, our 750 watt PulseSMART system uniquely combines the best lamp, ballast and fixture technology available. See pages 88-89 for more detail. Very efficient, only 28 watts loss on a 750 watt system Fits into the economical Superbay ballast housing Available in 277V

12

electronic ballasts
Introducing EL Series Electronic Ballast

el series steel housing

The new Hubbell Industrial Lighting EL Series E-Reg Electronic Ballast delivers a new level of HID performance: Lower operating and maintenance costs. Better lumen maintenance light output depreciation cut 30%-50%. Fewer fixtures needed to light the same space over standard MH. Energy savings of more than 40% per year. Variable dimming to 50% of lamp power.

More Lumens

Electronic HID raises the performance of pulse start lamps to a new level. Electronic HID systems deliver 35% more light at mean lumen output than traditional probe-start systems and nearly 50% more light by end of life.

More Energy Efficient

Electronic HID systems are far more efficient, reducing operating costs up to 40% per year when compared to probe-start systems.

More Savings to the Bottom Line


Lumen Maintenance Comparison
100%

Regardless of the way you compare the products, Electronic HID represents the best solution for delivering great lighting at a great price.

86%
% IN IT IA L L U M E N S

86%
P E R C E N T DE S IG N L U ME N S

Cost Benefits of Improved Lumen Maintenance


140 120

Wasted energy for light output above what is required


P E R C E N T DE S IG N L U ME N S

140

120

More consistent light output means fewer wasted lumens, greater energy savings

75%
72%

100

100

64%
58% 140
120

80

Cost Benefits of Improved Lumen Maintenance


Pulse Start for Wasted energyMH light output with EL Series above what is required Pulse Start MH (magnetic ballast)
100% Design(magnetic Lumens @ 8000 hours
140 120

60

100% Design Lumens @ 8000 hours

80

More consistent light output means fewer wasted lumens, greater energy savings 20
0 0 4

40

Energy costs expended on insufficient light levels

60

100% Design Lumens @ 8000 hours

40

P E R C E N T DE S IG N L U ME N S

100 44% 80

P E R C E N T DE S IG N L U ME N S

100

Suggested relamping to maintain desired light levels (@12,000 hours)


8 12 16 20

20

0 0 4 8

Suggested relamping to maintain desired light levels (@18,000 hours)


12 16 20

Probe Start MH ballast) 4


Energy costs expended on insufficient light levels12 8
OPERATING HOURS (1000's)

80

30%
40 20

60

60

100% Design Lumens @ 8000 hours

OPERATING HOURS (1000's)

OPERATING HOURS (1000's)

OLD Magnetic Probe Start HID


20
Suggested relamping to maintain desired light levels (@18,000 hours)
12 16

NEW EL Series Electronic HID

40

16

10-Year Overall Cost of Ownership = 36% Reduction


0 0 0 4 8 12 16 20 0 4 8 20

Suggested relamping to maintain desired light levels (@12,000 hours)

20

400W Probe Start

400W Pulse Start

Magnetic CWA OPERATING HOURS of Consider an example (1000's)lighting a new 300 ft. OPERATING HOURS (1000's) space with a 24 ft. ceiling to a minimum illumination levelMagnetic SCWA x 300 ft. retail of OLD Magnetic a work-plane height NEWinches. Never has Lumens per Lamp 100 footcandles atProbe Start HID 30 EL Series Electronic HIDa new technology had the potential to contribute so significantly 31,000 Mean 23,400 to the bottom line. Even with the ELs higher initial cost, the savingsFixture a 10-year operating cycle can be as high as 36%, as 452 Input Watts per over 458 the following model illustrates: Number of Fixtures Required
400W Pulse Fixture Cost, each Start

462 $15

352 $25

400W Probe Start Magnetic CWA Mean Lumens per Lamp Input Watts per Fixture Number of Fixtures Required Fixture Cost, each Lamp Cost, each Fixture Cost, total Lamp Cost, total Installation Labor Installation Materials Total Installed Cost Savings Annual Energy Costs (@ $0.10/KWH) Savings 10 Year Lamp Replacements and Cleanings Savings 10 Year Cost of Ownership Savings Savings vs. 400W Probe Start 23,400 458 462 $150 $15 $69,300 $6,930 $23,100 $138,600 $237,930 _______ $105,798 _______ $46,200 _______ $1,342,110 _______ _______

Lamp Cost, each

Magnetic SCWA 31,000

400W Pulse Start $150 Electronic E-Reg 37,000 425 295 $275

$175 $61,600 $8,800 $17,600 $105,600 $193,600

Fixture Cost, total452 Lamp Cost, total 352 Installation Labor $175

$69,300 $6,930 $23,100

Installation Materials $25 Total Installed$61,600 Cost Savings Savings


$8,800 $105,600 $193,600 $79,552

$25 $138,600

$237,930 $81,125 _______


$7,375 $14,750 $105,798 $88,500 _______ $191,750

18.6%
$79,552

Annual Energy$17,600(@ $0.10/KWH) Costs 10 Year Lamp Replacements and Cleanings 18.6% Savings 10 Year Cost of Ownership 25% Savings
$44,000

25%
$44,000

19.4%
$62,688 $36,875

$46,200 _______

5%
$1,033,120

$1,342,110 41% _______

23%

5% Savings vs. 400W Probe Start


$1,033,120

20%
$855,500

_______

$308,990

23%

36%

$308,990

$486,610

13

highbay vs. lowbay lighting


Spacing to Mounting Height Ratio
Spacing to mounting height ratio (S/MH) determines the optimal spacing between fixture centers for uniform lighting. If the spacing between fixtures exceeds the optimal spacing determined with the S/MH ratio, then dark spots may occur on the work plane. All indoor HID fixtures have a S/MH ratio. Optimal spacing is calculated by multiplying the S/MH ratio by the mounting height. For example: If the S/MH ratio is 1.5 and the mounting height is 15 ft., then the distance between fixtures should not exceed 1.5 x 15, or 22.5 feet.
Recommended Mounting Heights for HID

Industrial areas can be divided into low bay and high bay applications. A low bay area is generally one where mounting heights are 20 feet (6 meters) or less, and a high bay area is one where mounting heights are over 20 feet (6 meters). Highbay Fixtures are designed to deliver the maximum amount of light onto the work plane. They are not recommended for mounting heights below 20 ft. To accommodate these higher mounting heights, highbay fixtures feature reflectors that produce a concentrated light beam, providing effective horizontal task illumination. If mounted below 20 ft., highbay fixtures can cause glare, eye fatigue, harsh shadows, and dark spots on the work plane. High bay luminaires use reflectors to direct light downward. Low bay luminaires generally include a refractor to spread out the light for even light distribution and low luminaire brightness. The refractor may be used alone or in combination with a reflector. Lowbay Fixtures are designed to deliver a more evenly spread light onto the work plane. The reflector of low bay fixtures has an acrylic lens on the bottom to diffuse the light and provide excellent horizontal and vertical illumination. This helps to reduce glare while providing a wider beam pattern to accommodate for lower mounting heights.

Wattage 1000 Watt 300 to 400 Watt 175 to 250 Watt 70 to 150 Watt

Recommended Mounting Height 35 to 40 Highbay 20 to 40 Highbay 12 to 20 Lowbay 8 to 15 Lowbay

superbay
The Superbay Series is designed for many years of demanding, heavy-duty industrial service. Typical applications include heavy and light industrial plants, warehouses, and aircraft hangers as well as retail.

Ballast Module

Rugged, two piece, die cast aluminum with corrosion resistant Lektrocote white finish. All electrical components are mounted directly to the ballast module for maximum heat dissipation and cooler operation.

Additional Features

Quick and easy to install. UL Listed for 55C ambient operation and damp locations. Porcelain mogul base socket. 40C for 1000 watt.

Accessories

Accessories are available for the Superbay Series. They must be ordered separately and installed in the field.

Mounting Accessories

Mounting accessories are available for the Superbay Series. They must be ordered separately. See Options and Accessories or Power Hook / Mounting Accessories.

Options

Options for the Superbay Series are factory installed. Order with fixture by adding suffix. See Options and Accessories, pages 60-70.

Superbay luminaires are not for outdoor use or wind buffeted locations.

14

tribay
New Generation of Specification Grade Industrial Lighting
Three key features define the Tribay: 65C rating for high ambient locations Wet location standard (not available with OU, HG16, HG22 or WA optics) Specification grade ballast housing handles all wattages up through 1000W Tribay offers a variety of optics for all highbay and lowbay needs, whatever the industry from textiles to automotive, paper mill to retail.

Additional Features HG22 Glass Optics

High performance acrylic reflectors free from glare and harsh shadows for unsurpassed visual comfort are available Energy-Saving switch level dimming option Corrosion resistant hardware Electro-Reg 2.0 metal halide system available (the efficiency of HPS, with white light performance) Superior 600W Super Sodium available (30,000+ hours lamp life, quick cold start, instant hot restrike)

Broad Range of Ballast Technology

CWA, Mag-Reg, PLA, CWA, SCWA Electro-Reg, Isolated Secondary Quad-Tap, Tri-Tap, 220V 50Hz Remote/Offset ballast housing option for restricted luminaire height applications 65C ambient temperature rating on highbays - standard 250 and 400 watt ideal for harsh environment; ensures longer ballast life

Hubbell Quick-Zone WA Prismatic Acrylic (22 and 25)

UL listed for electrical make and break under load. Replaces power hooks for instant installation or removal and replacement of luminaires. Pendant or ceiling through-wire mounting. Mounting box may be shipped ahead of luminaires for installation. The Quick-Zone disconnect is UL listed for all system voltages and is marked upon installation with the correct line voltage. Only 3 15/16 high, it saves almost eight inches of additional mounting height needed for conventional power hooks. All entry hubs are threaded 3/4. See mounting method under Options and refer to Accessories section for separate shipment of Quick-Zone boxes.

Superwatt Optic

Quick-Zone Controlux Optic

15

HIGHBAY

superbay
ballast housings

Features
Rugged, two-piece, die cast aluminum ballast housing with corrosion resistant Lektrocote white finish. Electrical components are mounted directly to the aluminum housing for cool operation and long life. SPECIFICATIONS 150-450 WATT Fits with any of fourteen different optical systems. Ballasts are high power factor with 180 Class H insulation. SPECIFICATIONS 750 WATT PuLSE SMART Uses new 750 watt Pulse Start lamp. Fits with any of seven different optical systems. Must use GE lamps: Hubbell #261-0726-9901 clear or #261-0722-9901 coated SPECIFICATIONS 1000 WATT Fits with any of four different optical systems. Ballasts are high power factor with 180 Class H insulation. LISTINGS Superbay ballast housings are certified to UL 1598, CSA 22.2 No. 250.0-00 and tested to 55C ambient operation. 1000 watt Superbay ballast housing is certified to CSA 22.2 (40C ambient operation). Suitable for damp locations

Mogul Base

Ordering Information
150-450 watt

Example: BLA
Series

400
Watts

H
Source

8
Volts

WH
Color

Series BLA Superbay Series Wattage 150 150 watt Pulse Start MH or HPS 175 175 watt MH or Pulse Start MH 200 200 watt Pulse Start MH only 250 250 watt MH, Pulse Start MH or HPS 320 320 watt Pulse Start MH only 350 350 watt Pulse Start MH or Electro-Reg 400 400 watt MH, Pulse Start MH, HPS or Electro-Reg 450 450 watt Pulse Start MH only Source H Metal Halide S High Pressure Sodium W Pulse Start Metal Halide E Electro-Reg (40C) Voltage 1 120V Electro-Reg 2 208V Electro-Reg 3 240V Electro-Reg 4 277V Electro-Reg 5 480V Electro-Reg 6 Tri-Tap - 120/277/347V (not available on E-Reg) 7 600V (isolated secondary only) 8 Quad-Tap (multi-tap) 120/208/240/277V (not available on E-Reg) F 347V (single voltage only) Color WH White (standard) GR Gray (optional)

750 watt PULSE SMaRt 1000 watt


Series BL Superbay Series Wattage 750 750 watt Quasi Resonant MH Source Q Quasi Resonant MH Voltage 4 277V Optics LM 29" Lowbay (40C) SD 19" Reflector w/ downlight (55C) Su 19" Reflector w/ uplight (55C) WA22 22" Clear Prismatic Acrylic (30C) CH-Ou60 23" Reflector w/ uplight (55C) (requires BL-FLUSH-MT-KIT) WA25 25" Clear Prismatic Acrylic (35C) EG 19" Spun Aluminum Highbay (55C) Color WH White (standard) GR Gray (optional) Series BLA Superbay Series Wattage 1000 1000 watt MH, Pulse Start MH or HPS Source H Metal Halide S High Pressure Sodium W Pulse Start Metal Halide Voltage 5 480V 6 Tri-Tap - 120/277/347V 8 Quad-Tap (multi-tap) 120/208/240/277V Color WH White (standard) GR Gray (optional)

NOTE: MV lamp will operate on MH ballast. NOTE: Energy Saving Linear Reactor Pulse Start ballast available, consult factory. 277V only. NOTE: Options must be added as suffix to Catalog Number. Accessories must be ordered separately. NOTE: Pulse Smart (quasi-resonant) ballasts cannot be dimmed.

For a complete list of options and accessories see pages 60 to 70.

Dimensions
B D

150-450 & 750 watt


A

1000 watt

Slick-On Quick-On

A 91/2" 241 mm A 91/2" 241 mm

B 2 51 mm B 11/8" 29 mm

C 91/2" 241 mm C 85/8" 219 mm

Slick-On

A B C D 6 117/8" 911/16" 21/8" 6.0 301.6 mm 152.4 mm 246.2 mm 53.9 mm D 11/8" 29 mm

2.124 A B C 7/8" 6" 911/16" Quick-On 11 9.693 301.6 mm 152.4 mm 246.2 mm

Slick-On Bracket Pendant, Ceiling, Through-Wire Mounting (shipped optional)

Quick-On Bracket Pendant Mount (shipped standard)

16
11.874

superbay optics Ordering Information: BL Optical Assembly Modules


Catalog Number BL-AL1 BL-BI2 BL-EG BL-LB1 BL-PA23 BL-SD1 BL-Su1 BL-Ou606 BL-WA255 CH-SW CH-LM BL-WA224 BL-WW224
1 2 3 4 5 6

HIGHBAY

Description 19 Aisle lighter reflector 14 Highbay reflector 19 Enclosed and gasketed reflector 23 Lowbay reflector/refractor 16 Prismatic acrylic reflector 19 Highbay downlight reflector 19 Highbay reflector with uplight 23 Highbay reflector 25 Prismatic acrylic reflector Superwatt optics 29 Lowbay reflector/refractor 22 Clear prismatic acrylic reflector 22 Opaque prismatic acrylic reflector

Diameter 19 14 19 23 16 19 19 23 25 22 29 22 22

Weight lbs. (kg) 2.5 (1.1) 1.75 (0.8) 6.75 (3.1) 8.25 (3.7) 3 (1.4) 2.25 (1) 2.25 (1) 5.0 (2.2) 8.25 (3.7) 10 (4.5) 10.75 (4.9) 6.5 (3) 6.5 (3)

Requires BL-LR19 when used with E or S rated lamps. Requires BL-LR-14 when used with E or S rated lamps. Requires BL-PK_ENC when used with E or S rated lamps. Requires WA2-ENC, WA22-CDL, WA22-DLR when used with E or S rated lamps. If used with 400W, reduces thermal listing to 40C. Requires WA25-DLR when used with E or S rated lamps. Requires CH-ENC-23 when used with E or S rated lamps.

Glass Highbay units BL-1510S8-HGX-16-WH BL-175H8-HGX-16-ENC-WH BL-250H8-HGX-16-ENC-WH BL-250S8-HGX-16-WH BL-320W8-HGX-16-WH BL-350W8-HGX-16-WH BL-400H8-HGX-16-WH BL-400S8-HGX-16-WH BL-400W8-HGX-16-WH BL-150S8-HGX-22-WH BL-175H8-HGX-22-ENC-WH BL-250S8-HGX-22-WH BL-320W8-HGX-22-WH BL-350W8-HGX-22-WH BL-400H8-HGX-22-WH BL-400S8-HGX-22-WH BL-400W8-HGX-22-WH HG-ENC-22

BL-HGO16 BL-HGE16

BL-HGO22 BL-HGE22

BL-HGX16 and BL-HGX22 require a special ballast housing.

BL-Ou60

BL-AL

BL-BI

BL-PA2

BL-SD

BL-Su

BL-EG

BL-LB1

BL-WA25

CH-SW

CH-LM

BL-WA22

BL-WW22

17

HIGHBAY

el series
bi

Features
The EL Series BI is ideal for light manufacturing areas, warehouse and retail aisles. Steel ballast housings should be used in areas with minimal airborne contaminants. The EL Series BI wwfeatures an Anodal finished 14 diameter spun aluminum reflector for improved optical performance. Field adjustable brackets provide narrow, medium and wide lighting distributions for application flexibility. Steel housing with white polyester powder coat finish. All electrical components are positioned to assure unit will hang straight. Housing is ventilated for optimal thermal performance. Electronic ballast is 100% factory tested. Ballast will operate pulse start lamps only, from 200-277V.

Mogul Base

Glazed porcelain, vertical oriented, mogul-base socket with copper alloy, nickel-plated screw shell and center contact. UL listed 1500W, 600V, 4KV pulse rated. Protected version with pink exclusionary socket available. Listed to U.S. and Canadian safety standards.

Ordering Information
Series EL Electronic Highbay Series Wattage 32 320 watt Pulse Start MH 35 350 watt Pulse Start MH 40 400 watt MH, Pulse Start MH Ballast/Lamp System W Pulse Start Metal Halide Voltage 2 208V 3 240V 4 277V

Example:

EL - 400 - W Series Watts Ballast/

4 Volts

M Mounting

BI
Optics

Mounting Method D Quick Zone Electrical Disconnect - wiring box shipped with fixture E Quick Zone Electrical Disconnect - wiring box not shipped with fixture (wiring box must be shipped as accessory - CH-Q) L Less wiring box M With wiring box (standard construction)

Optics NM No Optics, housing made for BI reflector BI 14 spun aluminum highbay reflector with uplight Bottom Enclosure BL-LR-14 Bottom Enclosure Color WH White (standard)

For a complete list of options and accessories see pages 60 to 70.

Dimensions

B A

A B 25 15/16 16 3/8 658 mm 415 mm

C D 9 9/16 14 11/16 243 mm 372 mm

18

Features
The EL Series EG is ideal for light manufacturing areas, warehouse and retail aisles. Steel ballast housings should be used in areas with minimal airborne contaminants. The EL-EG 19 diameter reflector system excludes dirt and dust, maintaining desired performance. It is white polyester powder coated and has a clear glass bottom lens. Note: shown with optional CFB (charcoal filter breather) on reflector. Steel housing with white polyester powder coat finish. All electrical components are positioned to assure unit will hang straight. Housing is ventilated for optimal thermal performance. Electronic ballast is 100% factory tested. Ballast will operate pulse start lamps only, from 200-277V. Glazed porcelain, vertical oriented, mogul-base socket with copper alloy, nickel-plated screw shell and center contact. UL listed 1500W, 600V, 4KV pulse rated. Protected version with pink exclusionary socket available. Listed to U.S. and Canadian safety standards.

el series
eg

HIGHBAY

Mogul Base

Ordering Information
Series EL Electronic Highbay Series Wattage 32 320 watt Pulse Start MH 35 350 watt Pulse Start MH 40 400 watt MH, Pulse Start MH Ballast/Lamp System W Pulse Start Metal Halide Voltage 2 208V 3 240V 4 277V

Example:

EL - 350 - W Series Watts Ballast/

4 Volts

M Mounting

EG
Optics

Mounting Method D Quick Zone Electrical Disconnect - wiring box shipped with fixture E Quick Zone Electrical Disconnect - wiring box shipped not with fixture (wiring box must be shipped as accessory - CH-Q) L Less wiring box M With wiring box (standard construction)

Optics NM No Optics, housing made for EG reflector EG 19 spun aluminum highbay enclosed & gasketed reflector Color WH White (standard)

For a complete list of options and accessories see pages 60 to 70.

Dimensions
B A

A 29 15/16 761 mm
C

B 11 1/2 292 mm

C 13 1/2 342 mm

D 19 483 mm

19

HIGHBAY

el series
su/sd/al

Features
The EL Series SU/SD/AL is ideal for light manufacturing areas, warehouse and retail aisles. Steel ballast housings should be used in areas with minimal airborne contaminants. The SU optic is ideally suited for new construction or retrofit lighting. The uplight component softens the overall brightness difference between the luminaire and surrounding area. The SD optic is an Anodal finished 19 spun aluminum reflector engineered for applications requiring downlight only. The AL optic economically lights the vertical surfaces of warehouses and storage area stacks. Steel housing with white polyester powder coat finish. All electrical components are positioned to assure unit will hang straight. Housing is ventilated for optimal thermal performance.

Mogul Base

Electronic ballast is 100% factory tested. Ballast will operate pulse start lamps only, from 200-277V. Glazed porcelain, vertical oriented, mogul-base socket with copper alloy, nickel-plated screw shell and center contact. UL listed 1500W, 600V, 4KV pulse rated. Protected version with pink exclusionary socket available. Listed to U.S. and Canadian safety standards.

Ordering Information
Series EL Electronic Highbay Series Wattage 32 320 watt Pulse Start MH 35 350 watt Pulse Start MH 40 400 watt MH, Pulse Start MH Ballast/Lamp System W Pulse Start Metal Halide Voltage 2 208V 3 240V 4 277V

Example: EL - 400 - W Series Watts Ballast/

4 Volts

M Mounting

SU
Optics

Mounting Method D Quick Zone Electrical Disconnect - wiring box shipped with fixture E Quick Zone Electrical Disconnect - wiring box not shipped with fixture (wiring box must be shipped as accessory - CH-Q) L Less wiring box M With wiring box (standard construction)

Optics NM No Optics, housing made for SU/SD/AL reflector Su 19 spun aluminum highbay reflector with uplight SD 19 spun aluminum highbay reflector with downlight only AL 19 spun aluminum highbay aisle lighter reflector Bottom Enclosure BL-LR-19 Bottom Enclosure Color WH White (standard)

For a complete list of options and accessories see pages 60 to 70.

Dimensions
B A C D

Su SD

A 28 1/4 718 mm

B C D 16 11/32 11 15/16 19 415 mm 303 mm 483 mm

A 28 1/4 718 mm

B 14 31/32 380 mm

C 13 5/16 338 mm

D 19 483 mm

AL
20

A 27 1/2 699 mm

B 14 7/32 361 mm

C 13 5/16 338 mm

D 19 483 mm

Features
Heavy-duty, die cast Lektrocote aluminum ballast housing stands up to the toughest environments for years of maintenance-free industrial service. Optically superior 19 Anodal finished aluminum reflector.

tribay

HIGHBAY

eu/ou

Extended thermal certification (65C) assures long service life for ballast and electrical components. Optional Quick-Zone electrical disconnect sets a new convenience standard for installation and maintenance. Available with energy-saving Electro-Reg ballast (250W, 350W and 400W). EU suitable for wet locations, OU suitable for damp locations. 250 to 400W requires minimum 90C supply wire. 400W plus to 1000W requires minimum 105C supply wires.
Mogul Base

Ordering Information
Series CH Tribay Wattage 25 250W MH, Pulse Start MH, HPS or Electro-Reg2, 3 32 320W Pulse Start MH only 35 350W Pulse Start MH or Electro-Reg2, 3 40 400W MH, Pulse Start MH, HPS or Electro-Reg2, 3 45 450W Pulse Start MH only 75 750W Pulse Start MH only4 Ballast/Lamp System Electro-Reg1, 3 E H MH - Standard PLA HPS, Mag-Reg HPS M S Standard CWA, AL, HPS HPS, CWI (Canada) F MH, CWI (Canada) D Pulse Start MH W

Example:

CH
Series

40
Watts

H
Ballast

8
Volts

M
Mount

OU
Optics

Voltage 120V2 1 2 208V. Not available in 250 & 350W Electro-Reg2 3 240V. Not available in 250 & 350W Electro-Reg2 4 277V2 5 480V2 6 Tri-Tap 120/277/347V (not available on Electro-Reg) 600V (Isolated secondary only) 7 Quad-Tap 120/208/240/277V 8 (not available on Electro-Reg) Less ballast and cap O (250 & 400W only) 220/240V 50 Hz E 347V2 F

Mounting Method Quick Zone Electrical D disconnect - wiring box shipped with fixture Quick Zone Electrical E disconnect - wiring box not shipped with fixture (wiring box must be shipped as accessory - CH-Q) Less wiring box (wiring box L shipped as accessory - CH-B) With wiring box M (standard construction) Optics 19 Enclosed Highbay Eu Reflector (wet location) 19 Open Highbay Reflector Ou (damp location) No Optics, enclosed highbay NA No Optics, open highbay NB Bottom Enclosure CH-ENC-19 Bottom Enclosure (OUonly)
1 2 3 4 250, 350 and 400W MH only Single voltage designations for Electro-Reg, Mag-Reg or isolated secondary ballast only Electro-Reg shipped standard with premium lamp included 55C standard, for 65C use -HA option

Note Bottom enclosures are required unless lamps designated as suitable for open use are used. Note Options must be added as suffix to catalog number. Accessories must be ordered separately.

For a complete list of options and accessories see pages 60 to 70.

Dimensions

A B C 27 7/8 15 13/16 12 7/8 708 mm 386 mm 327 mm

D 19 483 mm

21

HIGHBAY

tribay
eu60/ou60

Features
Heavy-duty, die cast Lektrocote aluminum ballast housing stands up to the toughest environments for years of maintenance-free industrial service. Optically superior 23 Anodal finished aluminum reflector. Extended thermal certification (65C) assures long service life for ballast and electrical components. Optional Quick-Zone electrical disconnect sets a new convenience standard for installation and maintenance. Available with Electro-Reg ballast (250W, 350W and 400W). EU60 suitable for wet locations, OU60 suitable for damp locations. Minimum 105C supply conductors.

Mogul Base

Ordering Information

Example: CH
Series

10
Watts

H
Ballast

4
Volts

M
Mount

- EU60
Optics

Series CH Wattage 10

Tribay

1000W MH or Pulse Start MH or HPS1 Ballast/Lamp System MH - Standard PLA H Standard CWA, AL, HPS S MH, CWI (Canada) D W Pulse Start MH Voltage 5 480V Tri-Tap (120, 277, 347V) 6 Quad Tap (120, 208, 240, 277V) 8

Mounting Method Quick Zone Electrical D disconnect - wiring box shipped with fixture Quick Zone Electrical E disconnect - wiring box not shipped with fixture (wiring box must be shipped as accessory - CH-Q) Less wiring box (wiring box L shipped as accessory - CH-B) With wiring box M (standard construction)

Optics Eu60

23 Enclosed Highbay Reflector (wet location) 23 Open Highbay Reflector Ou60 (damp location) No Optics, enclosed highbay NA No Optics, open highbay NB Bottom Enclosure CH-ENC-23 Bottom Enclosure (OU only)

1 55C standard, for 65C use -HA option Note Options must be added as suffix to catalog number. Accessories must be ordered separately. Note Bottom enclosures are required unless lamps designated as suitable for open use are used.

For a complete list of options and accessories see pages 60 to 70.

Dimensions

A 30 13/16 783 mm

B 15 3/16 386 mm

C 15 5/8 397 mm

D 23 584 mm

22

Features
The BI optic features an Anodal finished 14 diameter spun aluminum reflector and two-piece, die cast aluminum ballast housing. Field adjustable brackets provide narrow, medium and wide lighting distributions for application flexibility.

superbay

HIGHBAY

bi 14 aluminum

Rugged, two-piece, die cast aluminum ballast housing with corrosion-resistant Lektrocote white finish. Unit Pack Catalog Logic BL400H8WHBIUPL (lamp included in Unit Pack) available. Up to 55C ambient. Suitable for damp location. Minimum 90C supply conductors.
Mogul Base

Ordering Information

Example:

BL
Series

400
Watts

H
Source

8
Volts

BI
Optics

WH
Color

Series Superbay Series BL Wattage 150 150W Pulse Start MH or HPS 175 175W MH or Pulse Start MH 200 200W Pulse Start MH only 250 250W MH, Pulse Start MH, or HPS 320 320W Pulse Start MH only 350 350W Pulse Start MH or Electro-Reg 400 400W MH, Pulse Start MH, HPS, or Electro-Reg 450 Pulse Start MH only

Source H S W E Voltage 1 2 3 4 5 6 7 8

Metal Halide High Pressure Sodium Pulse Start Metal Halide Electro-Reg (40C) 120V Electro-Reg only 208V Electro-Reg only 240V Electro-Reg only 277V Electro-Reg only 480V Electro-Reg only Tri-Tap (120, 277, 347V) 600V (isolated secondary only) Quad Tap (120, 208, 240, 277V)

14 Spun aluminum highbay reflector with uplight Bottom Enclosure BL-LR-14 Bottom Enclosure Color White (standard) WH Gray (optional) GR
Note MV lamp will operate on MH ballast. Note Energy Saving Linear Reactor Pulse Start ballast available - consult factory. 277V only. Note Bottom enclosures are required unless lamps designated as suitable for open use are used. Note Options must be added as suffix to catalog number. Accessories must be ordered separately.

Optics BI

For a complete list of options and accessories see pages 60 to 70.

Dimensions
A 22 3/16 - 24 7/16 564 - 621 mm 21 5/16 - 23 9/16 541 - 598 mm B C 14 1/4 9 1/2 362 mm 241 mm 14 1/4 8 5/8 362 mm 219 mm D 9 7/16 240 mm 9 7/16 240 mm E 9 1/2 241 mm 9 7/16 240 mm F 2 51 mm 1 1/8 29 mm

Slick-On Quick-On

23

HIGHBAY

superbay
eg 19 aluminum

Features
The Superbay EG 19 diameter reflector system excludes dirt and dust, maintaining desired performance. It is Lektrocoted and has a clear glass bottom lens. Two-piece, die cast aluminum ballast housing with corrosion-resistant Lektrocote white finish. All electrical components are mounted directly to the ballast module for maximum heat dissipation and cooler operation. Quick and easy to install. Porcelain mogul base socket. Standard mounting method is the Quick-On with the larger Slick-On available. Up to 55C ambient. Suitable for damp location. Minimum 90C supply conductors.

Mogul Base

Ordering Information

Example:

BL
Series

350
Watts

W
Source

8
Volts

EG
Optics

WH
Color

Series Superbay Series BL Wattage 150 150W Pulse Start MH or HPS 175 175W MH or Pulse Start MH 200 200W Pulse Start MH only 250 250W MH, Pulse Start MH, or HPS 320 320W Pulse Start MH only 350 350W Pulse Start MH or Electro-Reg 400 400W MH, Pulse Start MH, HPS, or Electro-Reg 450 450W Pulse Start MH only 750 750W Quasi Resonant

Source H S W E Q Voltage 1 2 3 4 5 6 8 F

Metal Halide High Pressure Sodium Pulse Start Metal Halide Electro-Reg Quasi Resonant (277V only) 120V Electro-Reg only 208V Electro-Reg only 240V Electro-Reg only 277V Electro-Reg only 480V Electro-Reg only Tri-Tap (120, 277, 347V) Quad Tap (120, 208, 240, 277V) 347V

Optics EG Color WH GR

19 Spun aluminum highbay enclosed and gasketed reflector White (standard) Gray (optional)

Note MV lamp will operate on MH ballast. Note Energy Saving Linear Reactor Pulse Start ballast available - consult factory. 277V only. Note Options must be added as suffix to catalog number. Accessories must be ordered separately.

For a complete list of options and accessories see pages 60 to 70.

Dimensions

Slick-On Quick-On

A B C 22 3/4 19 9 1/2 578 mm 483 mm 241 mm 21 7/8 19 8 5/8 556 mm 483 mm 219 mm

D 13 1/4 337 mm 13 1/4 337 mm

E 9 1/2 241 mm 9 1/2 241 mm

F 2 51 mm 1 1/8 29 mm

24

Features
The Superbay OU60 Series is ideally suited for new construction or retrofit lighting. The uplight component softens the overall brightness difference between the luminaire and surrounding areas. Rugged, two-piece, die cast aluminum ballast housing with corrosion-resistant Lektrocote white finish. Field-adjustable brackets provide multiple lighting distributions for applications requiring narrow, medium or wide beam spread. Standard mounting method is the Quick-On with the larger Slick-On available. Up to 35C ambient. Suitable for damp location. Minimum 90C supply conductors.

superbay

HIGHBAY

ou60 23 aluminum

Ordering Information

Example:

BL
Series

- 1000
Watts

W
Source

8
Volts

- OU60
Optics

WH
Color

Series Superbay Series BL Wattage 1000 1000W MH, Pulse Start MH or HPS

Source H S W Voltage 5 6 8

Metal Halide High Pressure Sodium Pulse Start Metal Halide 480V Tri-Tap (120, 277, 347V) Quad Tap (120, 208, 240, 277V)

Optics Ou60 23 Spun aluminum highbay reflector with uplight Bottom Enclosure CHENC23 Bottom enclosure Color WH White (standard) Gray (optional) GR

Note MV lamp will operate on MH ballast. Note Bottom enclosures are required unless lamps designated as suitable for open use are used. Note Options must be added as suffix to catalog number. Accessories must be ordered separately.

For a complete list of options and accessories see pages 60 to 70.

Dimensions
G E F C

Slick-on
A D

Quick-on

A 27 1/8-29 1/8 689-740 mm 27 7/8-29 7/8 708-761 mm

B C 23 9 3/4 584.2 mm 246.4 mm 23 9 3/4 584.2 mm 246.4 mm

D 15 3/4 400 mm 15 3/4 400 mm

E 6 152.4 mm 6 152.4 mm

F 2 1/8 54 mm 2 1/8 54 mm

G 11 7/8 301.5 mm 11 7/8 301.5 mm

25

HIGHBAY

superbay
su/sd/al

Features
The SU optic is ideally suited for new construction or retrofit lighting. The uplight component softens the overall brightness difference between the luminaire and surrounding area. The SD optic is an Anodal finished 19 spun aluminum reflector engineered for applications requiring downlight only. The AL optic economically lights the vertical surfaces of warehouses and storage area stacks. Rugged, two-piece, die cast aluminum ballast housing with corrosionresistant Lektrocote white finish. Field adjustable reflector provides multiple lighting distributions. Standard mounting is the Quick-On with the larger Slick-On available.

Mogul Base

Up to 55C ambient. Suitable for damp location. Minimum 90C supply conductors.

Ordering Information
Series Superbay Series BL Wattage 150 150W Pulse Start MH or HPS 175 175W MH or Pulse Start MH 200 200W Pulse Start MH only 250 250W MH, Pulse Start MH, or HPS 320 320W Pulse Start MH only 350 350W Pulse Start MH or Electro-Reg 400 400W MH, Pulse Start MH, HPS, or Electro-Reg 450 450W Pulse Start MH only

Example: BL
Series

400
Watts

W
Source

8
Volts

AL
Optics

WH
Color

Source H S W E Voltage 1 2 3 4 5 6 8 F

Metal Halide High Pressure Sodium Pulse Start Metal Halide Electro-Reg (40C) 120V Electro-Reg only 208V Electro-Reg only 240V Electro-Reg only 277V Electro-Reg only 480V Electro-Reg only Tri-Tap (120, 277, 347V) Quad Tap (120, 208, 240, 277V) 347V

19 Spun aluminum highbay reflector with uplight 19 Spun aluminum highbay SD reflector with downlight only AL 19 Spun aluminum highbay aisle lighter reflector Bottom Enclosure BL-LR-19 Bottom enclosure Color White (standard) WH Gray (optional) GR
Note MV lamp will operate on MH ballast. Note Energy Saving Linear Reactor Pulse Start ballast available - consult factory. 277V only. Note Bottom enclosures are required unless lamps designated as suitable for open use are used. Note Options must be added as suffix to catalog number. Accessories must be ordered separately.

Optics Su

For a complete list of options and accessories see pages 60 to 70.

Dimensions
Su
Slick-On Quick-On A 23 5/8 - 25 7/8 600 - 657 mm 22 3/8 -25 578 - 635 mm A 23 5/8 - 25 7/8 600 - 657 mm 22 3/8 - 25 578 - 635 mm A 23 5/8 - 25 7/8 600 - 657 mm 22 3/4 - 25 578 - 635 mm B C 18 3/4 9 1/2 476 mm 241 mm 18 3/4 8 5/8 476 mm 219 mm B C 18 3/4 9 1/2 476 mm 241 mm 18 3/4 8 5/8 476 mm 219 mm B C 18 7/8 9 1/2 479 mm 241 mm 18 7/8 8 5/8 479 mm 219 mm D 11 3/4 298 mm 11 3/4 298 mm D 13 1/4 337 mm 13 1/4 337 mm D 13 1/4 337 mm 13 1/4 337 mm E 9 1/2 241 mm 9 1/2 241 mm E 9 1/2 241 mm 9 1/2 241 mm E 9 1/2 241 mm 9 1/2 241 mm F 2 51 mm 1 1/8 29 mm F 2 51 mm 1 1/8 29 mm F 2 51 mm 1 1/8 29 mm

SD
Slick-On Quick-On

AL
Slick-On Quick-On

26

Features

utility highbay

HIGHBAY

bl400hb/bl400hbq

The BL400HB is ideal for warehouses, work shops, auto maintenance, factories, etc. and for applications with ceiling heights of 15-30 ft. Die-cast housing with protective white powder paint finish. Easy mounting box for 3/4 conduit. Cast safety hook included for hanging. 400 watt metal halide, 120/208/240/277 volt, HPF CWA ballast. Lamp included. Unit pack available. 16 aluminum reflector with three position mounting for various distribution spreads. Glass bottom lens and retaining clamp band allows use with standard, stock metal halide lamps. NEC 2005 compliant. UL listed for use in damp locations.

Ordering Information
Catalog Number BL4000HB BL4000HBQ Description Highbay Unit Pack, 400 watt MH, Multi-Tap w/ optic, lamp, & hook Highbay Unit Pack, 400 watt MH, Multi-Tap w/ optic, lamp, & hook - QSS

Dimensions
9.2 (223 mm) 14.0 (358 mm) 3.8 (97 mm) 10.6 (269 mm) 24.6 (624 mm) 8.8 (224 mm) 5.2 (132 mm) 3.0 (77 mm)

2.6 5.0 (66 mm) (128 mm)

9.4 (240 mm) 16.2 (412 mm)

27

el series
lb1

Features
The EL Series LB1 is ideal for light manufacturing areas, warehouse and retail aisles. Steel ballast housings should be used in areas with minimal airborne contaminants. Reflector is spun, high purity, heavy-gauge aluminum with white Lektrocote paint finish inside and out. Hinged and latched with corrosion-resistant steel hardware. Computer-designed acrylic refractor (polycarbonate available) is UV stabilized for long life and durability. Refractor provides square distribution to enhance uniformity and increase fixture spacing. Steel housing with white polyester powder coat finish. All electrical components are positioned to assure unit will hang straight. Housing is ventilated for optimal thermal performance.

LOWBAY

Mogul Base

Electronic ballast is 100% factory tested. Ballast will operate pulse start lamps only, from 200-277V. Glazed porcelain, vertically oriented, mogul-base socket with copper alloy, nickel-plated screw shell and center contact. UL listed 1500W, 600V, 4KV pulse rated. Protected version with pink exclusionary socket available. Listed to U.S. and Canadian safety standards.

Ordering Information
Series EL Electronic Highbay Series Wattage 32 320 watt Pulse Start MH 35 350 watt Pulse Start MH 40 400 watt MH, Pulse Start MH Ballast/Lamp System W Pulse Start Metal Halide Voltage 2 208V 3 240V 4 277V

Example: EL - 400 - W Series Watts Ballast/

4 Volts

M Mounting

BI
Optics

Mounting Method D Quick Zone Electrical Disconnect - wiring box shipped with fixture E Quick Zone Electrical Disconnect - wiring box not shipped with fixture (wiring box must be shipped as accessory - CH-Q) L Less wiring box M With wiring box (standard construction)

Optics NN No Optics, housing made for LB1 optics LB1 23 Spun Aluminum Lowbay with bottom lens refractor Color WH White (standard)

For a complete list of options and accessories see pages 60 to 70.

Dimensions

A 30 5/8 778 mm
C

B C 12 15/16 17 3/4 328 mm 450 mm

D 22 15/16 581 mm

28

Features
The EL Series LM is ideal for light manufacturing areas, warehouse and retail aisles. Steel ballast housings should be used in areas with minimal airborne contaminants. The EL-LM Series is designed for many years of demanding, heavy-duty industrial service. Ideally suited for low to medium mounting heights in areas requiring good horizontal uniformity and high vertical illumination. LMs low brightness refractor produces wide distribution without harsh shadows while projecting light into machinery for optimum yet comfortable visibility. 29 spun aluminum with white Lektrocote finish. Hinged and latched with corrosion-resistant steel hardware for ease in relamping. Computer-designed acrylic refractor (polycarbonate available) is UV stabilized for long life and durability. Prismatic refractor provides square distribution to enhance uniformity and increase fixture spacing. Steel housing with white polyester powder coat finish. All electrical components are positioned to assure unit will hang straight. Housing is ventilated for optimal thermal performance. Electronic ballast is 100% factory tested. Ballast will operate pulse start lamps only, from 200-277V. Glazed porcelain, vertically oriented, mogul-base socket with copper alloy, nickel-plated screw shell and center contact. UL listed 1500W, 600V, 4KV pulse rated. Protected version with pink exclusionary socket available. Listed to U.S. and Canadian safety standards.

el series
lm

LOWBAY

Mogul Base

Ordering Information
Series EL Electronic Highbay Series Wattage 32 320 watt Pulse Start MH 35 350 watt Pulse Start MH 40 400 watt MH, Pulse Start MH Ballast/Lamp System W Pulse Start Metal Halide Voltage 2 208V 3 240V 4 277V

Example:

EL - 400 - W Series Watts Ballast/

4 Volts

M Mounting

BI
Optics

Mounting Method D Quick Zone Electrical Disconnect - wiring box shipped with fixture E Quick Zone Electrical Disconnect - wiring box not shipped with fixture (wiring box must be shipped as accessory - CH-Q) L Less wiring box M With wiring box (standard construction)

Optics NE No Optics, housing made for LM optic LM 29 Spun Aluminum Lowbay with bottom lens enclosure Color WH White (standard)

Max Ambient Temperature Chart Wattage Controlux 320 MH 55C 350 MH 55C 400 MH 55C

For a complete list of options and accessories see pages 60 to 70.

Dimensions
B

A C

A 30 7/8 784 mm

B 11 1/2 292 mm

C 19 3/8 492 mm

D 29 1/8 739 mm

29

tribay
lm

Features
The Tribay Series LM is designed to provide superb workplace visual comfort and high vertical footcandles with state-of-the-art ballast/lamp systems. A precision optical design with very low surface brightness allows low mounting of this luminaire (10 to 25 feet). Square distribution improves overall illumination uniformity with 2:1 or greater fixture spacing. The Tribay LM Series is particularly well suited for industrial areas where machinery or other vertical obstructions may cause shadows or uneven illumination with standard luminaires. Up to 65C ambient. Suitable for wet locations. 250 to 400W requires minimum 90C supply wire. 400W plus to 750W requires minimum 105C supply wires.

LOWBAY

Mogul Base

Ordering Information
Series CH Tribay Wattage 250W MH, Pulse Start MH, HPS or 25 Electro-Reg2, 3 32 320W Pulse Start MH only 350W Pulse Start MH or 35 Electro-Reg2, 3 40 400W MH, Pulse Start MH, HPS or Electro-Reg2, 3 45 450W Pulse Start MH only 600W HPS only 60 (Instant restrike Super Sodium) 750W Pulse Start MH only 75 Ballast/Lamp System Electro-Reg1, 3 E H MH - Standard PLA HPS, Mag-Reg HPS M Standard CWA, AL, HPS S HPS, CWI (Canada) F MH, CWI (Canada) D Pulse Start MH W

Example:

CH
Series

40
Watts

W
Ballast

5
Volts

M
Mount

LM
Optics

Voltage 120V2 1 2 208V. Not available in 250W Electro-Reg2 3 240V 277V2 4 5 480V2 6 Tri-Tap 120/277/347V (not available on Electro-Reg) 600V (Isolated secondary only) 7 Quad-Tap 120/208/240/277V 8 (not available on Electro-Reg) Less ballast and cap O (250 & 400W only) 220/240V 50 Hz E 347V2 F Max Ambient Temperature Chart Wattage LM 250 HPS 65C 400 HPS 55C 600 HPS 45C 250 MH 65C 320 MH 55C 350 MH 55C 400 MH 55C 450 MH 50C 750 MH 40C

Mounting Method Quick Zone Electrical disconnect D - wiring box shipped with fixture Quick Zone Electrical disconnect E wiring box not shipped with fixture (wiring box must be shipped as accessory - CH-Q) Less wiring box (wiring box shipped L as accessory - CH-B) With wiring box M (standard construction) Optics LM Lowbay Optics No Optics, housing for LM reflector NE
1 2 250, 350 and 400W MH only Single voltage designations for Electro-Reg, Mag-Reg or isolated secondary ballast only 3 Electro-Reg shipped standard with premium lamp included Note Options must be added as suffix to catalog number. Accessories must be ordered separately.

For a complete list of options and accessories see pages 60 to 70.

Dimensions

A 31 1/2 800 mm

B 11 7/8 302 mm

C 19 5/8 498 mm

D 29 1/8 740 mm

30

Features
The Superbay LB1 is suited for low to medium mounting heights in areas requiring good horizontal uniformity and high vertical illumination. The LB1 Series low brightness refractor produces wide light distribution without harsh shadows, projecting light into machinery for optimum yet comfortable visibility. Ideal for food processing, automotive assembly, manufacturing and warehouse applications. Reflector is spun, high purity, heavy-gauge aluminum with white Lektrocote paint finish inside and out. Hinged and latched with corrosion-resistant steel hardware. Computer-designed acrylic refractor (polycarbonate available) is UV stabilized for long life and durability. Refractor provides square distribution to enhance uniformity and increase fixture spacing. Up to 55 ambient. Unit Pack Catalog Logic BL400H8WHLB1UPL (lamp included in Unit Pack). Porcelain mogul base socket. Meets UL 1598, CSA No. 22.2.

superbay

lb1

LOWBAY

Mogul Base

Ordering Information
Series Superbay Series BL Wattage 150 150W Pulse Start MH or HPS 175 175W MH or Pulse Start MH 200 200W Pulse Start MH only 250 250W MH, Pulse Start MH, or HPS 320 320W Pulse Start MH only 350 350W Pulse Start MH or Electro-Reg 400 400W MH, Pulse Start MH, HPS, or Electro-Reg 450 450W Pulse Start MH only

Example: BL
Series Source H S W E Voltage 1 2 3 4 5 6 8 F

320
Watts

W
Source

5
Volts Optics LB1 Color WH GR

LB1
Optics

WH
Color

Metal Halide High Pressure Sodium Pulse Start Metal Halide Electro-Reg (40C) 120V Electro-Reg only 208V Electro-Reg only 240V Electro-Reg only 277V Electro-Reg only 480V Electro-Reg only Tri-Tap (120, 277, 347V) Quad Tap (120, 208, 240, 277V) 347V

23 Spun aluminum lowbay with bottom lens refractor White (standard) Gray (optional)

Note MV lamp will operate on MH ballast. Note Energy Saving Linear Reactor Pulse Start ballast available - consult factory. 277V only. Note Options must be added as suffix to catalog number. Accessories must be ordered separately.

For a complete list of options and accessories see pages 60 to 70.

Dimensions

Slick-On Quick-On

A B C 27 23 1/8 9 1/2 686 mm 587 mm 241 mm 26 1/8 23 1/8 8 5/8 664 mm 587 mm 219 mm

D 17 1/2 444 mm 17 1/2 444 mm

E 2 51 mm 1 1/8 29 mm

31

superbay
lm

Features
The Superbay LM Series is designed for many years of demanding, heavy-duty industrial service. Ideally suited for low to medium mounting heights in areas requiring good horizontal uniformity and high vertical illumination. LMs low brightness refractor produces wide distribution without harsh shadows while projecting light into machinery for optimum yet comfortable visibility. Typical applications include assembly areas, warehouses, food processing plants, automotive applications, storage areas and maintenance garages. 29 spun aluminum with white Lektrocote finish. Hinged and latched with corrosion-resistant steel hardware for ease in relamping. Computer-designed acrylic refractor (polycarbonate available) is UV stabilized for long life and durability. Prismatic refractor provides square distribution to enhance uniformity and increase spacing.

LOWBAY

Mogul Base

Up to 55C ambient. Suitable for damp location.

Ordering Information

Example:

BL
Series

450
Watts

W
Source

8
Volts

LM
Optics

WH
Color

Series Superbay Series BL Wattage 150 150W Pulse Start MH or HPS 175 175W MH or Pulse Start MH 200 200W Pulse Start MH only 250 250W MH, Pulse Start MH, or HPS 320 320W Pulse Start MH only 350 350W Pulse Start MH or Electro-Reg 400 400W MH, Pulse Start MH, HPS, or Electro-Reg 450 450W Pulse Start MH only 750 750W Quasi Resonant (40C)

Source H S W E Q Voltage 1 2 3 4 5 6 8 F

Metal Halide High Pressure Sodium Pulse Start Metal Halide Electro-Reg (40C) Quasi Resonant (277V only) 120V Electro-Reg only 208V Electro-Reg only 240V Electro-Reg only 277V Electro-Reg only 480V Electro-Reg only Tri-Tap (120, 277, 347V) Quad Tap (120, 208, 240, 277V) 347V

Optics LM Color WH GR

29 Spun aluminum lowbay with bottom lens refractor White (standard) Gray (optional)

Note MV lamp will operate on MH ballast. Note Energy Saving Linear Reactor Pulse Start ballast available - consult factory. 277V only. Note Options must be added as suffix to catalog number. Accessories must be ordered separately.

For a complete list of options and accessories see pages 60 to 70.

Dimensions
A B C 28 3/4 28 1/2 9 1/2 730 mm 724 mm 241 mm 27 7/8 28 1/2 8 5/8 708 mm 724 mm 219 mm D 19 3/8 492 mm 19 3/8 492 mm E 9 1/2 241 mm 9 1/2 241 mm F 2 51 mm 1 1/8 29 mm

Slick-On Quick-On

32

Features
Computer designed, injection molded, UV stabilized acrylic refractor permanently spun into a specular anodized aluminum reflector provides low brightness, high vertical illumination, and efficiencies of over 80% The refractor projects a square light distribution for superior horizontal footcandle uniformity Three plated steel latches retain the optical system to the housing Rugged, heavy-duty, die cast housing has a durable white Lektrocote finish to provide cooler operating temperatures for longer electrical component life High power factor (HPF), class H insulated, 60 Hz ballast operates down to -20F (MH) and -40F (HPS). Ballast is heat sunk to its die cast housing for optimum heat dissipation Completely enclosed and gasketed Certified to UL 1598, CSA 22.2 No. 250.0-00, suitable for wet locations Porcelain mogul base socket, 4KV rated Optional NSF certified to NSF standard C-2 (add -FP to end of catalog number) 55C ambient operating temperatures (for 250W MH, 40C standard) and UL wet location listed

microlux

ml

LOWBAY

Mogul Base

Ordering Information

Example: ML
Series

P
Mount

175
Watts

H
Source

8
Volts

AR
Refractor

- WH
Color

Series Microlux Series ML Mounting Pendant mount P Ceiling thru-wire box C Wattage 070 70W HPS 100 100W HPS 150 150W HPS or Pulse Start MH 175 175W MH or Pulse Start MH 250 250W MH, HPS or Pulse Start MH

Source H S W Voltage 5 6 8

Metal Halide1 High Pressure Sodium Pulse Start Metal Halide 480V Tri-Tap (120, 277, 347V) Quad Tap (120, 208, 240, 277V)

Refractor Acrylic refractor AR Polycarbonate refractor PR Color WH White (standard) Gray (optional) GR
1 MV lamp will operate on MH ballast. Note Options must be added as suffix to catalog number. Accessories must be ordered separately.

For a complete list of options and accessories see pages 60 to 70.

Dimensions
C
A 23 5/8 600 mm B 14 1/2 368 mm C 2 7/8 73 mm

33

utility lowbay
bl400lb/bl400lbq series

Features

The BL400LB is ideal for warehouses, work shops, auto maintenance, factories, etc. and for applications with ceiling heights of 15-30 ft. Die-cast housing with protective white powder paint finish. Easy mounting box for 3/4 conduit. Cast safety hook included for hanging. 400 watt metal halide, 120/208/240/277 volt, HPF CWA ballast. Lamp included. Unit pack available.

LOWBAY

16 aluminum reflector with white powder paint finish for corrosion resistance and uniform distribution. Drop acrylic refractor and clamp band allows use with standard, stock metal halide lamps. Provides lamp image shielding from below. NEC 2005 compliant. UL listed for use in damp locations.

Ordering Information
Catalog Number BL400LB BL400LBQ Description Lowbay Unit Pack, 400 watt MH, Multi-Tap w/ optic, lamp, & hook Lowbay Unit Pack, 400 watt MH, Multi-Tap w/ optic, lamp, & hook - QSS

For a complete list of options and accessories see pages 60 to 70.

Dimensions
9.2 (223 mm) .39 (10 mm) 24.6 (624 mm) 10.6 (269 mm) 3.4 (87 mm) 8.8 (224 mm) 3.0 (77 mm) 2.6 5.0 (66 mm) (128 mm)

9.4 (240 mm) 16.2 (412 mm)

34

Features
The EL Series HGX16/HGX-22 is ideal for light manufacturing areas, warehouse and retail aisles. Steel ballast housings should be used in areas with minimal airborne contaminants. The HGE-16/HGE-22 and HGO-16/HGE-22 Series glass reflectors are manufactured from shock and impact resistant borosilicate glass, providing good uplight and three dimensional lighting. These high quality glass optics come with a specially designed ballast housing engineered for maximum performance. The reflector is mounted to the ballast housing by a combination of die cast aluminum socket housing and rigid, zinc-coated wire form. The die cast aluminum socket housing is available as an open unit (HGO-16) or as an enclosed unit (HGE-16). The open unit allows airflow through the inside of the glass optic to help maintain a clean reflector. The open unit is damp location listed. The enclosed unit seals off the top of the glass optic to prevent dirt and dust from entering the reflector and is damp location listed. To seal the bottom, order lens shown below. Both glass optics offer the best resistance to the widest variety of corrosive industrial chemicals and are easily cleaned and maintained. Steel housing with white polyester powder coat finish. All electrical components are positioned to assure unit will hang straight. Housing is ventilated for optimal thermal performance. Electronic ballast is 100% factory tested. Ballast will operate pulse start lamps only, from 200-277V. Glazed porcelain, vertically oriented, mogul-base socket with copper alloy, nickel-plated screw shell and center contact. UL listed 1500W, 600V, 4KV pulse rated. Protected version with pink exclusionary socket available. Listed to U.S. and Canadian safety standards.

el series
hgx-16/hgx-22

Mogul Base

GLASS

Ordering Information
Series EL Electronic Highbay Series Wattage 32 320 watt Pulse Start MH 35 350 watt Pulse Start MH 40 400 watt MH, Pulse Start MH Ballast/Lamp System W Pulse Start Metal Halide Voltage 2 208V 3 240V 4 277V

Example:

EL - 400 -

W -

4 -

M -

BI

Series Watts Ballast/ Volts Mounting Method D Quick Zone Electrical Disconnect - wiring box shipped with fixture E Quick Zone Electrical Disconnect - wiring box shipped not with fixture (wiring box must be shipped as accessory - CH-Q) L Less wiring box M With wiring box (standard construction)

For a complete list of options and accessories see pages 60 to 70.

Mounting Optics Optics NH No Optics, housing made for HGX-16 NI No Optics, housing made for HGX-22 HGE-16 16 Glass Reflector/Enclosed (lower luminaire retainer included standard) HGO-16 16 Glass Reflector/Open (lower luminaire retainer included standard) HGE-22 22 Glass Reflector/Enclosed (lower luminaire retainer included standard) HGO-22 22 Glass Reflector/Open (lower luminaire retainer included standard) Bottom Enclosure Glass HGENC16 Bottom Enclosure HGENC22 Bottom Enclosure Color WH White (standard)

Dimensions
B

HGX-16
A B C D 27 11 1/2 15 1/2 16 11/16 685 mm 292 mm 393 mm 424 mm
A

HGX-22
A B C D 26 7/8 11 1/2 15 3/8 22 1/16 682 mm 292 mm 390 mm 560 mm

A C

35

tribay
hgx-16/hgx-22

Features
The HGE-16/HGE-22 and HGO-16/HGE-22 Series glass reflectors are manufactured from shock and impact resistant borosilicate glass, providing good uplight and three dimensional lighting. The reflector is mounted to the ballast housing by a combination of die cast aluminum socket housing and rigid, zinc-coated wire form. The die cast aluminum socket housing is available as an open unit (HGO-16/HGO-22) or as an enclosed unit (HGE-16/HGE-22). The open unit allows air flow through the inside of the glass optic to help maintain a clean reflector. The open unit is damp location listed. The enclosed unit seals off the top of the glass optic to prevent dirt and dust from entering the reflector and is wet location listed. To seal the bottom, order lens shown below. Both glass optics offer the best resistance to the widest variety of corrosive industrial chemicals and are easily cleaned and maintained. Lower luminaire retainer is included. 65C ambient. Suitable for wet locations.

Mogul Base

Ordering Information GLASS


Series CH Wattage 25 32 35 40 45 60 75 10 Tribay 250W MH, Pulse Start MH, HPS or Electro-Reg2, 3 320W Pulse Start MH only 350W Pulse Start MH or Electro-Reg2, 3 400W MH, Pulse Start MH, HPS or Electro-Reg2, 3 450W Pulse Start MH only 600W HPS only (Instant restrike Super Sodium) 750W Pulse Start MH only4 1000W MH or Pulse Start MH (BT37 compact lamp included)

Example:

CH
Series

40
Watts

W
Ballast

8
Volts

M
Mount

HGE-16
Optics

1 2

250, 350 and 400W MH only Single voltage designations for Electro-Reg, Mag-Reg or isolated secondary ballast only 3 Electro-Reg shipped standard with premium lamp included. 4 80k lumen lamp included standard Note Bottom enclosures are required unless lamps are designated as suitable for open use are used. Note Options must be added as suffix to catalog number. Accessories must be ordered separately.

Ballast/Lamp System Electro-Reg1, 3 E H MH - Standard PLA HPS, Mag-Reg - HPS M Standard CWA, AL, HPS S HPS, CWI (Canada) F MH, CWI (Canada) D Pulse Start MH W Voltage 120V2 1 2 208V. Not available in 250 & 350W Electro-Reg2 3 240V. Not available in 250 & 350W Electro-Reg2 4 277V2 5 480V2 6 Tri-Tap 120/277/347V (not available on Electro-Reg) 600V (Isolated secondary only) 7 Quad-Tap 120/208/240/277V 8 (not available on Electro-Reg) Less ballast and cap O (250 & 400W only) 220/240V 50 Hz E 347V F

Mounting Method Quick Zone Electrical D disconnect - wiring box shipped with fixture Quick Zone Electrical E disconnect - wiring box not shipped with fixture (wiring box must be shipped as accessory - CH-Q) Less wiring box (wiring box L shipped as accessory - CH-B) With wiring box (standard M construction) Optics Medium to Wide Distribution HGE-16 16 Borosilicate glass reflector/ enclosed optic HGO-16 16 Borosilicate glass reflector/ open optic Narrow Distribution HGE-22 22 Borosilicate glass reflector/ enclosed optic HGO-22 22 Borosilicate glass reflector/ open optic HG-ENC-XX Tempered Glass Enclosure No Optics, housing made for NF glass reflector

For a complete list of options and accessories see pages 60 to 70.

Dimensions
HGX-16
A 27 686 mm B 11 7/8 302 mm C 15 1/8 384 mm D 18 5/8 473 mm

HGX-22
A 26 7/8 683 mm B 11 7/8 302 mm C 15 381 mm D 24 1/16 611 mm

36

Features
The HGE-16/HGE-22 and HGO-16/HGE-22 Series glass reflectors are manufactured from shock and impact resistant borosilicate glass, providing good uplight and three dimensional lighting. These high quality glass optics come with a specially designed ballast housing engineered for maximum performance. The reflector is mounted to the ballast housing by a combination of die cast aluminum socket housing and rigid, zinc-coated wire form. The die cast aluminum socket housing is available as an open unit (HGO-16/HGO-22) or as an enclosed unit (HGE-16/HGE-22). The open unit allows airflow through the inside of the glass optic to help maintain a clean reflector. The open unit is damp location listed. The enclosed unit seals off the top of the glass optic to prevent dirt and dust from entering the reflector and is damp location listed. To seal the bottom, order lens shown below. Both glass optics offer the best resistance to the widest variety of corrosive industrial chemicals and are easily cleaned and maintained. Slick-On is standard mounting method and a lower luminaire retainer is included.

superbay

hgo-16/hgo-22

Mogul Base

Ordering Information
Series BL Wattage 150 175 200 250 320 350 400 450 Superbay Series 150W Pulse Start MH or HPS 175W MH or Pulse Start MH 200W Pulse Start MH only 250W MH, Pulse Start MH, or HPS 320W Pulse Start MH only 350W Pulse Start MH or Electro-Reg 400W MH, Pulse Start MH, HPS, or Electro-Reg 450W Pulse Start MH only

Example: BL
Series Source H S W E Voltage 1 2 3 4 5 6 8 F

320
Watts

W
Source

8
Volts Optics

HGE-16
Optics

WH
Color

GLASS

Metal Halide High Pressure Sodium Pulse Start Metal Halide Electro-Reg (40C) 120V Electro-Reg only 208V Electro-Reg only 240V Electro-Reg only 277V Electro-Reg only 480V Electro-Reg only Tri-Tap (120, 277, 347V) Quad Tap (120, 208, 240, 277V) 347V

Medium to Wide Distribution HGE-16 16 Glass Reflector/Enclosed (lower luminaire retainer included standard) HGO-16 16 Glass Reflector/Open (lower luminaire retainer included standard) Narrow Distribution HGE-22 22 Borosilicate glass reflector/ enclosed optic HGO-22 22 Borosilicate glass reflector/ open optic HG-ENC Tempered Glass Enclosure Color WH White (standard) Gray (optional) GR

Note MV lamp will operate on MH ballast. Note Energy Saving Linear Reactor Pulse Start ballast available - consult factory. 277V only. Note Bottom enclosures are required unless lamps designated as suitable for open use are used. Note Options must be added as suffix to catalog number. Accessories must be ordered separately.

For a complete list of options and accessories see pages 60 to 70.

Dimensions
HGX-16
Slick-On A 24 5/8 625 mm B 18 11/16 475 mm C 9 1/2 241 mm D 15 1/8 384 mm E 9 1/2 241 mm F 2 51 mm

HGX-22
Slick-On

A 24 1/2 622 mm

B 24 610 mm

C 9 1/2 241 mm

D 15 381 mm

E 9 1/2 241 mm

F 2 51 mm

HGX-16

HGX-22

37

electronic superwatt /lightwatt

swx/lwx

Features

Superwatt and Lightwatt are engineered with high performance, industry leading optics and they are now available with Electronic ballasting. This gives you all of the benefits of the conventional magnetic ballasted units with a fully electronic, controllable, ballast. The Superwatt operates from 208V to 277V and accept lamps from 250 watt to 400 watt in Pulse Start. For mounting versions and options see page 52. The Lightwatt also operates from 208V to 277V with a a 150 watt Pulse Start. For Mounting versions and options see page 53. SWX and LWX are CSA listed.

Ordering Information
Catalog Number Description

Superwatt
SWD-EB-AP-WH SWD-EB-AC-WH SWW-EB-AP-WH SWW-EB-AC-WH LWj-EB-A-WH LWP-EB-A-WH LWC-EB-A-WH Superwatt, Superwatt, Superwatt, Superwatt, damp with electronic ballast, acrylic, pendant mount damp with electronic ballast, acrylic, ceiling mount wet with electronic ballast, acrylic, pendant mount wet with electronic ballast, acrylic, ceiling mount

Lightwatt
Lightwatt, junction box, electronic ballast, acrylic Lightwatt, pendant, electronic ballast, acrylic Lightwatt, ceiling, electronic ballast, acrylic

ACRYLIC

For a complete list of options and accessories see pages 60 to 70.

Dimensions
Superwatt Pendant Mount Superwatt Surface Mount
A A B E D C

Superwatt Pendant Mount


A 13 1/8 333 mm B 22 1/2 572 mm C 10 1/4 260 mm D 11 9/16 294 mm E 17 7/8 454 mm

Superwatt Surface Mount


A 24 1/4 616 mm B 6 15/16 176 mm C 17 7/8 454 mm

C B

(For mounting on concrete and steel on ly)

Lightwatt Pendant Lightwatt j-Box Mounting


A
Surface J-Box by others

Lightwatt Ceiling Thru-Wire


A
Top View

B
Mounting on a 4" square or octagonal box

B
Can be bal anced for mounting on swivel hangers, sloped ceilings, etc.

B
A 14 1/4 362 mm B 14 3/4 375 mm

38

A 12 1/4 311 mm

B 14 3/4 375 mm

A 14 356 mm

B 14 3/4 375 mm

Features
V-Spec sets the standard in maximum vertical surface illumination and color rendering. All the qualities you need plus energy savings. Perfect for the retail environment. LOWER OPERATING COSTS 10-point improvement in Lamp Lumen Maintenance allows for lower wattage lamps in retrofits or less fixtures in new construction. A high-efficiency electronic ballast with a high-output PulseArc lamp delivers 70% more mean lumens per watt than probe start metal halide lamps and 20% more mean lumens per watt than pulse start metal halide lamps. APPLICATION VERSATILITy Ballast housing design solves thermal, EMI, UL and mounting concerns. Multi-wattage capability one ballast runs 250, 300, 320, 350 or 400 watt quartz metal halide or ceramic metal halide lamps. Runs on 208-277 volts. 55C ambient temperature. IMPROVING QUALITy OF LIGHT Significantly reduces lamp color shift typical with HID lamps. Virtually eliminates flickering.
NOTE: PulseArc is a registered trademark of GE, Inc.

v-spec

sw series

Ordering Information
Part # uM25-40W-208-277 Part # uM25-40W-208-277-QS Part # CH-SW
With industry-leading engineered optics, V-Spec delivers not only floor (horizontal) footcandles but also critical shelf (vertical) illumination. More light on your products means improved customer satisfaction and sales.

V-Spec housing V-Spec housing w/ quartz SW optics

20

20 Mounting Height

ACRYLIC

31.6 30.4 29.5 28.6 27.5 25.7 24.7 21.3 8 20.7 14.3 14.2 10.3 10.5 28.9 24.2 5 30.2 29.1 24.4 30.8 30.6 36.1 10.5 30.6 22.9 14.9 23.7 15.2 10.3 35.9 24.3 15.4 10.3 38.0 24.9 15.6 11.4 26.0 16.7 11.7 34.5

20

34.7 38.1

Dimensions
A B

A B C 10 7/32 30 5/16 14 1/2 259 mm 769.6 mm 368.3 mm


D

D 22 1/2 572 mm

39

el series
pa2

Features
The EL Series PA2 is ideal for light manufacturing areas, warehouse and retail aisles. Steel ballast housings should be used in areas with minimal airborne contaminants. Designed for lower wattage and lower mounting heights. EL-PA2 Series 16 diameter acrylic reflector combines attractive appearance with superb performance. Field-adjustable brackets allow for medium to wide lighting distributions. For best performance and visual comfort, coated lamps are recommended. Electronic ballast is 100% factory tested. Ballast will operate pulse start lamps only, from 200-277V.

Mogul Base

Glazed porcelain, vertically oriented, mogul-base socket with copper alloy, nickel-plated screw shell and center contact. UL listed 1500W, 600V, 4KV pulse rated. Protected version with pink exclusionary socket available. Listed to U.S. and Canadian safety standards.

Ordering Information
Series EL Electronic Highbay Series Wattage 32 320 watt Pulse Start MH 35 350 watt Pulse Start MH 40 400 watt MH, Pulse Start MH Ballast/Lamp System W Pulse Start Metal Halide Voltage 2 208V 3 240V 4 277V

Example: EL - 400 - W Series Watts Ballast/

4 Volts

M Mounting

BI
Optics

ACRYLIC

Mounting Method D Quick Zone Electrical Disconnect wiring box shipped with fixture E Quick Zone Electrical Disconnect wiring box not shipped with fixture (wiring box must be shipped as accessory - CH-Q) L Less wiring box M With wiring box (standard construction)

Optics NP No Optics, housing made for PA2 optics PA2 16 Prismatic Acrylic Reflector Bottom Enclosure BL-PK-ENC Bottom Enclosure PA2-CDL Conical Bottom Enclosure PA2-DLR Drop Lens Bottom Enclosure Color WH White (standard)

For a complete list of options and accessories see pages 60 to 70.

Max Ambient Temperature Chart Wattage BL-PA2 BL-PA2 Open Enclosed 150 55C 55C 175 55C 55C 200 55C 55C 250 55C 50C 320 50C 40C 350 50C 40C 400 50C 40C

Dimensions

B A

A 24 1/2 723 mm

B C 17 5/8 10 15/16 447 mm 277 mm

D 16 1/4 412 mm

40

Features
The EL Series WA22/WW22 is ideal for light manufacturing areas, warehouse and retail aisles. Steel ballast housings should be used in areas with minimal airborne contaminants. The WA22 Series is designed for low to medium mounting heights in task areas demanding excellent vertical and horizontal illumination. The lightweight prismatic acrylic reflector generates wide, uniform light distribution with minimum glare and reduces harsh shadows on vertical work surfaces. Acrylic composition of the reflector versus glass enhances work place safety. Injection molded UV-stabilized acrylic. Field adjustable socket brackets allow for medium to wide distribution patterns. Use coated (diffuse) lamps for optimum photometric performance. Unit shown with optional WA22-CDL conical bottom enclosure. Steel housing with white polyester powder coat finish. All electrical components are positioned to assure unit will hang straight. Housing is ventilated for optimal thermal performance. Electronic ballast is 100% factory tested. Ballast will operate pulse start lamps only, from 200-277V. Glazed porcelain, vertically oriented, mogul-base socket with copper alloy, nickel-plated screw shell and center contact. UL listed 1500W, 600V, 4KV pulse rated. Protected version with pink exclusionary socket available. Listed to U.S. and Canadian safety standards.

el series
wa22/ww22

Mogul Base

Ordering Information
Series EL Electronic Highbay Series Wattage 32 320 watt Pulse Start MH 35 350 watt Pulse Start MH 40 400 watt MH, Pulse Start MH Ballast/Lamp System W Pulse Start Metal Halide Voltage 2 208V 3 240V 4 277V

Example:

EL - 400 - W Series Watts Ballast/

4 Volts

M Mounting Optics ND

WA22
Optics

Mounting Method D Quick Zone Electrical Disconnect wiring box shipped with fixture E Quick Zone Electrical Disconnect wiring box not shipped with fixture (wiring box must be shipped as accessory - CH-Q) L Less wiring box M With wiring box (standard construction)

ACRYLIC

No Optics, housing made for WA22/WW22 optics WA22 22 Wide Acrylic Reflector WW22 22 Opaque Prismatic Acrylic Bottom Enclosure WA2-ENC Bottom Enclosure WA22-CDL Conical Bottom Enclosure WA22-DLR Drop Lens Bottom Enclosure Color WH White (standard) Max Ambient Temperature Chart Wattage Open Enclosed 320 55C 40C 350 55C 40C 400 55C 40C

For a complete list of options and accessories see pages 60 to 70.

Dimensions
A 30 7/16 772 mm B 16 7/16 416 mm C 14 1/16 356 mm D 22 7/16 569 mm

41

el series
wa25

Features
The EL Series WA25 is ideal for light manufacturing areas, warehouse and retail aisles. Steel ballast housings should be used in areas with minimal airborne contaminants. The WA25 Series is designed for 20 to 30 foot mounting heights in areas that call for efficient three-dimensional illumination as well as good looks. Field adjustable socket brackets allow for medium to wide distribution patterns. For optimum performance and visual comfort, coated lamps are recommended. Steel housing with white polyester powder coat finish. All electrical components are positioned to assure unit will hang straight. Housing is ventilated for optimal thermal performance.

Mogul Base

Electronic ballast is 100% factory tested. Ballast will operate pulse start lamps only, from 200-277V. Glazed porcelain, vertically oriented, mogul-base socket with copper alloy, nickel-plated screw shell and center contact. UL listed 1500W, 600V, 4KV pulse rated. Protected version with pink exclusionary socket available. Listed to U.S. and Canadian safety standards.

Ordering Information
Series EL Electronic Highbay Series Wattage 32 320 watt Pulse Start MH 35 350 watt Pulse Start MH 40 400 watt MH, Pulse Start MH Ballast/Lamp System W Pulse Start Metal Halide Voltage 2 208V 3 240V 4 277V

Example:

EL - 400 - W Series Watts Ballast/

4 Volts

M Mounting Optics NL

WA25
Optics

Mounting Method D Quick Zone Electrical Disconnect wiring box shipped with fixture E Quick Zone Electrical Disconnect wiring box not shipped with fixture (wiring box must be shipped as accessory - CH-Q) L Less wiring box M With wiring box (standard construction)

No Optics, housing made for WA25 optics WA25 25 Wide Acrylic Reflector Bottom Enclosure WA25-ENC Bottom Enclosure WA25-DLR Drop Lens Bottom Enclosure Color WH White (standard) Max Ambient Temperature Chart Wattage Open Enclosed 320 55C 40C 350 55C 40C 400 55C 40C

ACRYLIC

For a complete list of options and accessories see pages 60 to 70.

Dimensions

A 29 3/4 755 mm
C

B 15 3/16 384 mm

C 14 5/8 371 mm

D 25 3/8 644 mm

42

Features
The EL Series SW is ideal for light manufacturing areas, warehouse and retail aisles. Steel ballast housings should be used in areas with minimal airborne contaminants. Superwatt 2.0 is designed to deliver comfortable, high efficiency illumination for both vertical as well as horizontal surfaces. With its 2.2:1 spacing-tomounting height ratio, it is well suited for low and medium mounting height applications requiring three-dimensional, high illumination. 27% uplight softens the brightness difference between luminaire and surrounding areas. The maximum downward candlepower is projected at 45 from vertical for wide distribution and the greatly reduced candlepower above 65 minimizes direct glare. Steel housing with white polyester powder coat finish. All electrical components are positioned to assure unit will hang straight. Housing is ventilated for optimal thermal performance. Electronic ballast is 100% factory tested. Ballast will operate pulse start lamps only, from 200-277V. Glazed porcelain, vertically oriented, mogul-base socket with copper alloy, nickel-plated screw shell and center contact. UL listed 1500W, 600V, 4KV pulse rated. Protected version with pink exclusionary socket available. Listed to U.S. and Canadian safety standards.

el series
sw

Mogul Base

Ordering Information
Series EL Electronic Highbay Series Wattage 32 320 watt Pulse Start MH 35 350 watt Pulse Start MH 40 400 watt MH, Pulse Start MH Ballast/Lamp System W Pulse Start Metal Halide Voltage 2 208V 3 240V 4 277V

Example:

EL - 400 - W Series Watts Ballast/

4 Volts

M Mounting

SW
Optics

Mounting Method D Quick Zone Electrical Disconnect wiring box shipped with fixture E Quick Zone Electrical Disconnect wiring box not shipped with fixture (wiring box must be shipped as accessory - CH-Q) L Less wiring box M With wiring box (standard construction)

Optics NC No Optics, housing made for SW optics SW Superwatt Optics Color WH White (standard)

ACRYLIC

Max Ambient Temperature Chart Wattage Superwatt 320 MH 45C 350 MH 40C 400 MH 40C

For a complete list of options and accessories see pages 60 to 70.

Dimensions
B

A 28 3/4 729 mm

B C D 12 15/16 15 13/16 22 9/16 328 mm 401 mm 572 mm

43

decorative highbay
hid series

Features

The Decorative Highbay is designed for retail stores, restaurants, cafeterias, gymnasiums, convention centers, auditoriums, and other large public spaces that require highly versatile, energy efficient light sources. The Decorative Highbay uses a single HID source. With optional multi-switch legs or dimming capabilities and instant-on operation, it offers virtually unlimited light level configurations. Housing is spun, heavy-gauge aluminum ballast compartment. This design ensures maximum cooling of the heat sensitive electronic components and promotes long, maintenance-free fixture life. Optics include an injection molded prismatic acrylic design with over 94% optical efficiency and 25% uplight. A white painted, low glare, spun aluminum reflector is also available. May be attached to a 1/2 or 3/4 pendant or bracket. Optional hook, loop, power hook receptacle, cord and plug and other convenience options are available. Ballast housing is white powder coat. Optional powder coat finishes are available at an additional cost. UL listed for wet locations. C-UL listed for Canada.

Ordering Information
Catalog Number HDH250H8WH HDH320W8WH HDH400H8WH AR22 SP20 Description Ballast Pods Decorative Highbay, 250 watt MH, Quad-Tap, white Decorative Highbay, 320 watt PS, Quad-Tap, white Decorative Highbay, 400 watt MH, Quad-Tap, white Reflectors 22 Acrylic Reflector 20 Spun Aluminum Reflector

ACRYLIC
44

For a complete list of options and accessories see pages 60 to 70.

Dimensions

Features
The WA22 Series is designed for low to medium mounting heights in task areas demanding excellent vertical and horizontal illumination. The lightweight prismatic acrylic reflector generates wide, uniform light distribution with minimum glare and reduces harsh shadows on vertical work surfaces. Acrylic composition of the reflector versus glass enhances work place safety. Injection molded UV-stabilized acrylic. Field adjustable socket brackets allow for medium to wide distribution patterns. Use coated (diffuse) lamps for optimum photometric performance. Unit shown with optional WA22-CDL conical bottom enclosure. 55C ambient. Suitable for damp locations. Minimum 90C supply conductors.
Mogul Base

tribay

wa22/ww22

Ordering Information
Series CH Wattage 25 Tribay

Example: CH
Series Voltage 1 2 3 4 5 6 7 8 O E F

40
Watts

W
Ballast

5
Volts

M
Mount

WA22
Options

250W MH, Pulse Start MH, HPS or Electro-Reg2, 3 32 320W Pulse Start MH only 350W Pulse Start MH or 35 Electro-Reg2, 3 40 400W MH, Pulse Start MH, HPS or Electro-Reg2, 3 45 450W Pulse Start MH only 750W Pulse Start MH only 75 Ballast/Lamp System Electro-Reg1, 3 E H MH - Standard PLA HPS Mag-Reg HPS M Standard CWA, AL, HPS S HPS, CWI (Canada) F MH, CWI (Canada) D Pulse Start MH W Max Ambient Temperature Chart Wattage Open Enclosed 250 55C 50C 320 55C 40C 350 55C 40C 400 55C 40C 450 50C 30C 750 30C N/A

120V2 208V. Not available in 250 & 350W Electro-Reg2 240V. Not available in 250 & 350W Electro-Reg2 277V2 480V2 Tri-Tap 120/277/347V (not available on Electro-Reg) 600V (Isolated secondary only) Quad-Tap 120/208/240/277V (not available on Electro-Reg) Less ballast and cap (250 & 400W only) 220/240V 50 Hz 347V

Mounting Method Quick Zone Electrical D disconnect - wiring box shipped with fixture Quick Zone Electrical E disconnect - wiring box not shipped with fixture (wiring box must be shipped as accessory - CH-Q) Less wiring box (wiring box L shipped as accessory - CH-B) With wiring box M (standard construction) Options 22 Clear Acrylic Prismatic WA22 Reflector 22 Opaque Prismatic Acrylic WW22 No Optics, housing for WA22 ND reflector Bottom Enclosure WA2-ENC Bottom Enclosure WA22-CDL Conical Bottom Enclosure WA22-DLR Drop Lens Bottom Enclosure
1 2 250, 350 and 400W MH only Single voltage designations for Electro-Reg, Mag-Reg or isolated secondary ballast only 3 Electro-Reg shipped standard with premium lamp included Note Bottom enclosures are required unless lamps designated as suitable for open use are used. Note Options must be added as suffix to catalog number. Accessories must be ordered separately.

ACRYLIC

For a complete list of options and accessories see pages 60 to 70.

Dimensions

A 29 3/16 741 mm

B 15 3/16 386 mm

C 14 356 mm

D 22 1/2 572 mm

45

tribay
wa25

Features
The WA25 Series is designed for 20 to 30 foot mounting heights in areas that call for efficient three-dimensional illumination as well as good looks. Field adjustable socket brackets allow for medium to wide distribution patterns. For optimum performance and visual comfort, coated lamps are recommended. Certified for 55C ambient operation for lamps up to 400 watts (for open units). Suitable for damp locations. 250 to 400W requires minimum 90C supply wire. 400W plus to 1000W requires minimum 105C supply wires.

Mogul Base

Ordering Information
Series Tribay CH Wattage 250W MH, Pulse Start MH, HPS or 25 Electro-Reg2, 3 32 320W Pulse Start MH only 350W Pulse Start MH or 35 Electro-Reg2, 3 40 400W MH, Pulse Start MH, HPS or Electro-Reg2, 3 45 450W Pulse Start MH only 600W HPS only 60 750W Pulse Start MH only 75 10 1000W MH or Pulse Start MH Ballast/Lamp System Electro-Reg1, 3 E H MH - Standard PLA HPS, Mag-Reg HPS M Standard CWA, AL, HPS S HPS, CWI (Canada) F MH, CWI (Canada) D Pulse Start MH W

Example:

CH
Series

40
Watts

H
Ballast

8
Volts

M
Mount

- WA25
Optics

ACRYLIC

Voltage 120V2 1 2 208V. Not available in 250 & 350W Electro-Reg2 3 240V. Not available in 250 & 350W Electro-Reg2 4 277V2 5 480V2 6 Tri-Tap 120/277/347V (not available on Electro-Reg) 600V (Isolated secondary only) 7 Quad-Tap 120/208/240/277V 8 (not available on Electro-Reg) Less ballast and cap O (250 & 400W only) 220/240V 50 Hz E 347V2 F Max Ambient Temperature Chart Wattage Open Enclosed 250 55C 55C 320 55C 40C 350 55C 40C 400 55C 40C 450 55C 35C 600 40C 25C 750 35C 25C 1000 25C N/A

Mounting Method Quick Zone Electrical D disconnect - wiring box shipped with fixture Quick Zone Electrical E disconnect - wiring box not shipped with fixture (wiring box must be shipped as accessory - CH-Q) Less wiring box (wiring box L shipped as accessory - CH-B) With wiring box M (standard construction) Optics NC No Optics, housing made for WA25 25 Clear Prismatic Acrylic WA25 Reflector Bottom Enclosure WA25-ENC Bottom Enclosure WA25-DLR Drop Lens Bottom Enclosure
1 2 250, 350 and 400W MH only Single voltage designations for Electro-Reg, Mag-Reg or isolated secondary ballast only 3 Electro-Reg shipped standard with premium lamp included Note Bottom enclosures are required unless lamps designated as suitable for open use are used. Note Options must be added as suffix to catalog number. Accessories must be ordered separately.

For a complete list of options and accessories see pages 60 to 70.

Dimensions

A 29 11/16 754 mm

B 15 3/16 386 mm

C 14 1/2 368 mm

D 25 1/4 641 mm

46

Features
The Superwatt Tribay Series is the answer to medium mounting height applications where you need to maximize both vertical and horizontal illumination. Its refractor provides up to 95% efficiency with 27% uplight that softens the brightness difference between the fixture and the surrounding areas. Maximum downward candle power is at 55 degrees from vertical for wide distribution and the lighting of vertical work surfaces. The Tribay is available in Metal Halide, High Pressure Sodium, Pulse Start and Electro-Reg ballasts from 250 to 450 watts. Suitable for wet locations. Minimum 90C supply conductors.

tribay

sw

Ordering Information
Series CH Tribay Wattage 25 250W MH, Pulse Start MH, HPS or Electro-Reg2 32 320W Pulse Start MH only 35 350W Pulse Start MH or Electro-Reg2 40 400W MH, Pulse Start MH, HPS or Electro-Reg2 45 450W Pulse Start MH only Ballast/Lamp System Electro-Reg 2.01, 3 E H MH - Standard PLA HPS Mag-Reg M S Standard CWA, AL, HPS HPS, CWI (Canada) F MH, CWI (Canada) D Pulse Start MH W

Example: CH
Series

25
Watts

E
Ballast

1
Volts

D
Mount

SW
Optics

Voltage 120V2 1 2 208V2 3 240V2 4 277V2 5 480V2 6 Tri-Tap 120/277/347V (not available on Electro-Reg) 600V (Isolated secondary only) 7 Quad-Tap 120/208/240/277V 8 (not available on Electro-Reg) 220/240V 50 Hz E 347V2 F

Mounting Method Quick Zone Electrical disconnect D - wiring box shipped with fixture Quick Zone Electrical disconnect E - wiring box not shipped with fixture (wiring box must be shipped as accessory - CH-Q) Less wiring box (wiring box shipped as L accessory - CH-B) With wiring box M (standard construction) Optics SW Superwatt Optics NC No Optics, housing made for Superwatt
1 2 3 Includes factory installed lamp. Includes system optimized lamp. Electro-Reg shipped standard with factory installed premium lamp. SLD is not compatible with Electro-Reg.

ACRYLIC

Accessories - Order Separately


Catalog Number CH-B CH-Q CH-TLRX5 CH-F CH-FF Description Wiring box with no electrical disconnect Wiring box with electrical disconnect Top Luminaire Retainer - for field installation Single Fuse Kit - 120, 277, 347V (fuses not included) Double Fuse Kit - 208, 240, 480V (fuses not included, not suitable in Canada) Max Ambient Temperature Chart Wattage Controlux 250 HPS 65C 400 HPS 55C 250 MH 65C 320 MH 50C 350 MH 45C 400 MH 40C 450 MH 35C

Dimensions
A 27 5/8 702 mm B 11 7/8 302 mm C 15 3/4 400 mm D 22 1/2 572 mm

47

superbay
pa2

Features
Designed for lower wattage and lower mounting heights. The PA2 Series 16 diameter acrylic reflector combines attractive appearance with superb performance. Field-adjustable brackets allow for medium to wide lighting distributions. For best performance and visual comfort, coated lamps are recommended. Up to 55C ambient. Suitable for damp location. Minimum 90C supply conductors.

Mogul Base

Ordering Information

Example:

BL
Series

250
Watts

W
Source

8
Volts

PA2
Optics

WH
Color

Series BL Wattage 150 175 200 250 320 350 400

Superbay Series 150W Pulse Start MH or HPS 175W MH or Pulse Start MH 200W Pulse Start MH only 250W MH, Pulse Start MH, or HPS 320W Pulse Start MH only 350W Pulse Start MH or Electro-Reg 400W MH, Pulse Start MH, HPS, or Electro-Reg

ACRYLIC

Source H S W E Voltage 1 2 3 4 5 6 8 F

Metal Halide High Pressure Sodium Pulse Start Metal Halide Electro-Reg 120V Electro-Reg only 208V Electro-Reg only 240V Electro-Reg only 277V Electro-Reg only 480V Electro-Reg only Tri-Tap (120, 277, 347V) Quad Tap (120, 208, 240, 277V) 347V

Optics 16 Prismatic acrylic reflector PA2 Bottom Enclosure BL-PK-ENC Bottom Enclosure PA2-CDL Conical Bottom Enclosure PA2-DLR Drop Lens Bottom Enclosure Color White (standard) WH Gray (optional) GR
Note MV lamp will operate on MH ballast. Note Energy Saving Linear Reactor Pulse Start ballast available, 277V only - Consult factory. Note Bottom enclosures are required unless lamps designated as suitable for open use are used. Note Options must be added as suffix to catalog number. Accessories must be ordered separately.

Max Ambient Temperature Chart Wattage BL-PA2 BL-PA2 Open Enclosed 150 55C 55C 175 55C 55C 200 55C 55C 250 55C 50C 320 50C 40C 350 50C 40C 400 50C 40C

For a complete list of options and accessories see pages 60 to 70.

Dimensions

Slick-On Quick-On

A 24 1/2 - 25 1/4 622 - 635 mm 22 1/8 - 22 7/8 562 - 581 mm

B 16 1/4 413 mm 16 1/4 413 mm

C 9 1/2 241 mm 8 5/8 219 mm

D 11 279 mm 11 279 mm

E 9 1/2 241 mm 9 1/2 241 mm

F 2 51 mm 1 1/8 29 mm

48

Features
The GM22 22 acrylic is designed especially for demanding gym applications. Clear lighting grade acrylic allows about 20% uplight for a well-lit application. The WA22 22 acrylic is designed as the economical solution to all nonimpact applications. Clear lighting grade acrylic allows about 20% uplight for a well-lit application. Unit Pack available: #BL400H8WHWAUPL. Use the WW22 22 diffuse acrylic for low glare applications. Limited uplight of about 10% allows more downlight for higher efficiencies. All reflectors have field-adjustable reflector brackets for medium to wide lighting distributions. Use coated lamp for best performance. Follow ambient temperature guidelines for longer life. Suitable for damp location. Minimum 90C supply conductors.

superbay
gm22/wa22/ww22

Mogul Base

Ordering Information

Example:

BL
Series

350
Watts

W
Source

8
Volts

- WA22
Optics

WH
Color

Series BL Wattage 150 175 200 250 320 350 400 450 750

Superbay Series 150W Pulse Start MH or HPS 175W MH or Pulse Start MH 200W Pulse Start MH only 250W MH, Pulse Start MH, or HPS 320W Pulse Start MH only 350W Pulse Start MH or Electro-Reg 400W MH, Pulse Start MH, HPS, or Electro-Reg 450W Pulse Start MH only Quasi Resonant

Source H S W E Q Voltage 1 2 3 4 5 6 8 F

Metal Halide High Pressure Sodium Pulse Start Metal Halide Electro-Reg Quasi Resonant (277V only) 120V Electro-Reg only 208V Electro-Reg only 240V Electro-Reg only 277V Electro-Reg only 480V Electro-Reg only Tri-Tap (120, 277, 347V) Quad Tap (120, 208, 240, 277V) 347V

Optics GM22

22 Wide Acrylic Reflector made for gym applications 22 Wide Acrylic Reflector WA22 22 Wide Translucent Acrylic WW22 Reflector Bottom Enclosure WA2-ENC Bottom Enclosure WA22-CDL Conical Bottom Enclosure WA22-DLR Drop Lens Bottom Enclosure Color White (standard) WH Gray (optional) GR

ACRYLIC

Max Ambient Temperature Chart Wattage Open Enclosed 250 55C 50C 320 55C 40C 350 55C 40C 400 55C 40C 450 40C 35C

Note MV lamp will operate on MH ballast. Note Energy Saving Linear Reactor Pulse Start ballast available - consult factory. 277V only. Note Bottom enclosures are required unless lamps designated as suitable for open use are used. Note Options must be added as suffix to catalog number. Accessories must be ordered separately.

For a complete list of options and accessories see pages 60 to 70.

Dimensions
Flush Mount Leg Mount Leg Mount
A 25 3/4 - 28 Slick-On 654 - 711 mm 24 7/8 - 27 1/8 Quick-On 632 - 689 mm B C 22 1/2 9 1/2 572 mm 241 mm 22 1/2 8 5/8 572 mm 219 mm D 14 356 mm 14 356 mm E 9 1/2 241 mm 9 1/2 241 mm E 9 1/2 241 mm 9 1/2 241 mm F 2 51 mm 1 1/8 29 mm F 2 51mm 1 1/8 29 mm

Flush Mount
Slick-On Quick-On A B C 23 1/2 22 1/2 9 1/2 597 mm 572 mm 241 mm 22 5/8 22 1/2 8 5/8 575 mm 572 mm 219 mm D 14 356 mm 14 356 mm

49

superbay
wa25

Features
WA25 acrylic reflector is designed for 15 to 30 foot mounting heights in areas that call for efficient three-dimensional illumination as well as good looks. Field-adjustable brackets allow for medium to wide lighting distributions. For optimum performance and visual comfort, coated lamps are recommended. UL listed for 55C ambient operation for lamps up to 400 watts and CSA certified up to 750 watts. Up to 55C ambient. Suitable for damp location. Minimum 90C supply conductors.

Mogul Base

Ordering Information
Series BL Wattage 150 175 200 250 320 350 400

Example:

BL
Series

450
Watts

W
Source

5
Volts

WA25
Optics

WH
Color

Superbay Series 150W Pulse Start MH or HPS 175W MH or Pulse Start MH 200W Pulse Start MH only 250W MH, Pulse Start MH, or HPS 320W Pulse Start MH only 350W Pulse Start MH or Electro-Reg 400W MH, Pulse Start MH, HPS, or Electro-Reg 450W Pulse Start MH only 750W Quasi Resonant

ACRYLIC

450 750

Source H S W E Q Voltage 1 2 3 4 5 6 8 F

Metal Halide High Pressure Sodium Pulse Start Metal Halide Electro-Reg Quasi Resonant (277V only) 120V Electro-Reg only 208V Electro-Reg only 240V Electro-Reg only 277V Electro-Reg only 480V Electro-Reg only Tri-Tap (120, 277, 347V) Quad Tap (120, 208, 240, 277V) 347V

Optics 25 Wide acrylic reflector WA25 Bottom Enclosure WA25-ENC Bottom Enclosure WA25-DLR Drop Lens Bottom Enclosure Color White (standard) WH Gray (optional) GR
Note MV lamp will operate on MH ballast. Note Energy Saving Linear Reactor Pulse Start ballast available - consult factory. 277V only. Note Bottom enclosures are required unless lamps designated as suitable for open use are used. Note Options must be added as suffix to catalog number. Accessories must be ordered separately.

Max Ambient Temperature Chart Wattage Open Enclosed 250 55C 55C 320 55C 40C 350 55C 40C 400 55C 40C 450 55C 35C 750 35C 25C

For a complete list of options and accessories see pages 60 to 70.

Dimensions
Leg Mount Flush Mount
Slick-On Quick-On A 26 5/16 - 28 1/16 668 - 711 mm 25 7/16 - 27 11/16 646 - 686 mm

Leg Mount
B C 25 3/8 9 1/2 645 mm 241 mm 25 3/8 8 5/8 645 mm 219 mm D 14 5/8 371 mm 14 5/8 371 mm E 9 1/2 241 mm 9 1/2 241 mm E 9 1/2 241 mm 9 1/2 241 mm F 2 51 mm 1 1/8 29 mm F 2 51 mm 1 1/8 29 mm

Flush Mount
Slick-On Quick-On A B C 24 1/8 25 3/8 9 1/2 613 mm 645 mm 241 mm 23 1/4 25 3/8 8 5/8 591 mm 645 mm 219 mm D 14 5/8 371 mm 14 5/8 371 mm

50

Features
Superwatt optic is designed to deliver comfortable, high efficiency illumination for both vertical as well as horizontal surfaces. With its 2.2:1 spacing-to-mounting height ratio, it is well suited for low and medium mounting height applications like machine shops, assembly areas, aisle lighting and areas requiring three-dimensional, high illumination. 27% uplight softens the brightness difference between luminaire and surrounding areas. The maximum downward candlepower is projected at 45 from vertical for wide distribution and the greatly reduced candlepower above 65 minimizes direct glare. Up to 55C ambient. Suitable for damp location. Minimum 90C supply conductors.

superbay

sw

Mogul Base

Ordering Information
Series Superbay Series BL Wattage 150 150W Pulse Start MH or HPS 175 175W MH or Pulse Start MH 200 200W Pulse Start MH only 250 250W MH, Pulse Start MH, or HPS 320 320W Pulse Start MH only 350 350W Pulse Start MH or Electro-Reg 400 400W MH, Pulse Start MH, HPS, or Electro-Reg 450 450W Pulse Start MH only

Example:

BL
Series

400
Watts

H
Source

8
Volts

SW
Optics

WH
Color

Source H S W E Voltage 1 2 3 4 5 6 8 F

Metal Halide High Pressure Sodium Pulse Start Metal Halide Electro-Reg 120V Electro-Reg only 208V Electro-Reg only 240V Electro-Reg only 277V Electro-Reg only 480V Electro-Reg only Tri-Tap 120/277/347V (not available on Electro-Reg) Quad-Tap 120/208/240/277V (not available on Electro-Reg) 347V

Optics SW Color WH GR

Superwatt optics White (standard) Gray (optional)

Note MV lamp will operate on MH ballast. Note Energy Saving Linear Reactor Pulse Start ballast available - consult factory. 277V only. Note Options must be added as suffix to catalog number. Accessories must be ordered separately.

ACRYLIC

Max Ambient Temperature Chart Wattage Superwatt 150 HPS 55C 250 HPS 55C 400 HPS 55C 175 MH 55C 200 MH 55C 250 MH 55C 320 MH 45C 350 MH 40C 400 MH 40C

For a complete list of options and accessories see pages 60 to 70.

Dimensions

Slick-On

A 25 7/16 646 mm

B 22 1/2 572 mm

C 9 1/2 241 mm

D 15 15/16 405 mm

51

superwatt
swd/sww hid

Features
Superwatt luminaire is designed to provide illumination on vertical as well as horizontal surfaces. The exclusive computer designed refractor has 95% efficiency. 27% uplight and greatly reduced glare. 2.2:1 spacing to mounting height Available in 175, 250, and 350W Electro-Reg 27% uplight softens the brightness difference between luminaire and surrounding areas. The maximum downward candlepower is projected at 45 from vertical for wide distribution and the greatly reduced candlepower above 65 minimizes direct glare. Superwatt luminaire is shipped in one carton, wired, with lamp installed and ready to hang. SWW Series offers optional NSF certification to NSF Standard C-2 (-FP, shown below). Up to 55 ambient

Mogul Base

Ordering Information
Series SW Listing D W Wattage 175 200 250 Superwatt Enclosed HID Damp location Wet location

Example: SW
Series Voltage 1 2 3 4 F 5 6 8 Refractor A P Mounting P C Color WH GR

D
Listing

- 400
Watts

W
Ballast

8
Volts

A
Refractor

P
Mount

- WH
Color

ACRYLIC

E-Reg MH, Pulse Start MH2 Pulse Start MH only E-Reg MH, Pulse Start MH, HPS2 320 Pulse Start MH only E-Reg Pulse Start MH2 350 400 MH, Pulse Start MH, or HPS Ballast/Lamp System Electro-Reg 175, 250, or 350W2 E H Metal Halide3 S High Pressure Sodium Pulse Start Metal Halide W

120V Electro-Reg only 208V 240V 277V Electro-Reg only 347V Electro-Reg only 480V Tri-Tap (120, 277, 347V) Quad Tap (120, 208, 240, 277V) Acrylic Polycarbonate (HPS only) Pendant Mount Ceiling Mount4 White (standard) Gray (optional)

Options F(X) HA CXHLPX CHL QSS QST SLD-1 SLD-2 SLD-3 LL S EM FP


1 2 3 4 5 6

Fusing6 55C listing (250W only) Cord, Hook/Loop, and 20A plug5, 6 2 exposed Cord Hook/Loop Quartz Standby includes 150W lamp Quartz Time Delay, Includes 150W lamp Switch Level Dimming with 120V control7, 8 Switch Level Dimming with 24V control7, 8 Switch Level Dimming with 277V control7, 8 Less Lamp Screw Down Refractor Emergency Quartz Lamp Socket National Sanitation Foundation Listed

Accessories - Order Separately


Catalog Number SW-WG Description Wireguard with safety chain.

For a complete list of options and accessories see pages 60 to 70.

7 8

Includes factory installed lamp. Includes system optimized lamp. E-Reg shipped standard with factory installed premium lamp. MV lamp will operate on MH ballast. Surface mounting units for mounting on concrete and steel only. For cord length, replace first X with 2, 4, 6, 8, 10 or 12. For voltage, replace second X with 1=120V, 2=277V, 3=240V, 4=277V, 5=480V, 6=347V. For motion sensor and switch level interface panel accessories, see Controls. SLD is not compatible with Electro-Reg.

Dimensions
Pendant Mount
A

Surface Mount
A B E

Pendant Mount
A 13 1/8 333 mm
C

B 22 1/2 572 mm

C 10 1/4 260 mm

D 11 9/16 294 mm

E 17 7/8 454 mm

Surface Mount
A 24 1/4 616 mm B 6 15/16 176 mm C 17 7/8 454 mm

C B

(For mounting on concrete and steel on ly)

52

Features
Lightwatt HID luminaire provides comfortable, high efficiency illumination on vertical and horizontal surfaces. Ideal for warehouses, shipping docks, stairwells, and especially for low ceiling areas. The Lightwatt is the premium luminaire for parking garages where the refractor projects light into, underneath and between parked vehicles eliminating dangerous shadows. Lightwatts photometric distribution provides over 15% uplight to soften the brightness difference between the luminaire and the surrounding areas and provide a three dimensional luminous environment. The computer designed refractor provides over 93% efficiency and spacing to mounting height ratio up to 1.9:1 Lightwatt luminaire is shipped in one carton, lamp installed. Housing is 99% copper free aluminum with white Lektrocote finish. Refractor is injection molded high performance acrylic. Up to 55C ambient

lightwatt

lw hid

Medium Base

Ordering Information
Series Lightwatt1 LW Mounting j J-Box (damp location)2 P Balanced Pendant (wet location) Ceiling thru-wire (wet location) C Pipe wall bracket (wet location) B Stanchion Davit (wet location) S Wattage MH, Pulse Start MH, or HPS (55C) 070 MH, Pulse Start MH, or HPS (55C) 100 Pulse Start MH or HPS (40C) 150 MH, Pulse Start MH, E-Reg (35C) 175 Lamp Type High Pressure Sodium S Metal Halide H E-Reg (175W Metal Halide) only E Pulse Start MH W

Example: LW
Series Voltage 1 4 5 6 8 F Refractor A P Color WH GR

J
Mount

175
Watts

H
Lamp

8
Volts

A
Refractor

- WH
Color

120V Electro-Reg only 277V Electro-Reg only 480V Tri-Tap 120/277/347V (not available on E-Reg) Quad-Tap 120/208/240/277V (not available on E-Reg) 347V Acrylic Polycarbonate (HPS only) White Lektrocote (standard) Gray Lektrocote

Options CHLPX F(X) LA LL LTP QSS QST


1 2

2 Cord, Hook/Loop, 20A Twist-Lock plug Fusing Latched Refractor Less Lamp Tamper Resistant Screws Quartz Standby includes 150W lamp Quartz Time Delay, Includes 150W lamp

Lamp included. Fast-Lock J-Box mounting-recessed J-Box requires installation of the included 1 1/2 extension ring.

ACRYLIC

For a complete list of options and accessories see pages 60 to 70.

Dimensions

A
Surface J-Box by others

Top View

B
Mounting on a 4" square or octagonal box

B
Can be bal anced for mounting on swivel hangers, sloped ceilings, etc.

j-Box Mounting
A 12 1/4 311 mm B 14 3/4 375 mm

Pendant
A 14 356 mm B 14 3/4 375 mm

Ceiling Thru-Wire
A 14 1/4 362 mm B 14 3/4 375 mm

53

decorative cfl
cfl series

Features
The Decorative Highbay is designed for retail stores, restaurants, cafeterias, gymnasiums, convention centers, auditoriums, and other large public spaces that require highly versatile, energy efficient light sources. The Decorative Highbay uses up to eight high output compact fluorescent lamps. With optional multi-switch legs or dimming capabilities and instanton operation, it offers virtually unlimited light level configurations. Housing is spun, heavy-gauge aluminum ballast compartment. This design ensures maximum cooling of the heat sensitive electronic components and promotes long, maintenance-free fixture life. Optics include an injection molded prismatic acrylic design with over 94% optical efficiency and 25% uplight. White painted, low glare, spun aluminum reflector also available. May be attached to a 1/2 or 3/4 pendant or bracket. Optional hook, loop, power hook receptacle, cord and plug and other convenience options are available. Ballast housing is white powder coat. Optional powder coat finishes are available at an additional cost. UL listed for wet locations. C-UL listed for Canada.

Ordering Information
Catalog Number HDF642WH HDF842WH AR22 SP20 Description Ballast Pods Decorative Highbay, 6-42 watt PLT, universal voltage, white Decorative Highbay, 8-42 watt PLT, universal voltage, white Reflectors 22 Acrylic Reflector 20 Spun Aluminum Reflector

CFL Dimensions
54

Features

superwatt

HIGHBAY

swf cfl

Instant On and Instant Re-strike The compact fluorescent lamps are on as soon as they are energized Good Color Compact Fluorescent lamps have a CRI of about 82 Better Lumen Maintenance Compact Fluorescent lamps have a flatter lumen maintenance curve Switch-able Dimming Since each ballast powers two lamps, an eight lamp unit can be switched to provide 25%, 50%, 75% and 100% light output Fail safe light output Since these are multiple lamp source units, they provide a measure of fail safe lighting that single source fixtures can not Shielding of Lamp Image The Superwatt refractor does a good job of breaking up the lamp image Superwatt Appearance In comparison to all of the other CFL highbays the Superwatt just plain looks better. In many applications this could tip the scales in your favor

LOWBAY

Ordering Information
Series SWF

Example:

GLASS

Superwatt Series Compact Fluorescent

Lamp Type/Wattage (4) 26W PLT 426 (4) 32W PLT 432 (4) 42W PLT 442 (6) 26W PLT 626 (6) 32W PLT 632 (6) 42W PLT 642 (8) 26W PLT 826 (8) 32W PLT 832 (8) 42W PLT 842

Refractor A P Options INC LL EM


Note Note Note Note

Acrylic Polycarbonate Incandescent Socket Less lamp One Emergency Ballast

All fixtures are wet location listed. All fixtures are pendant mount. Voltage is Universal 120/277V 50/60Hz. Options must be added as suffix to catalog number. Accessories must be ordered separately.

Accessories - Order Separately


Catalog Number SW-WG A-Lens P-Lens Description Wire Guard Acrylic Bottom Lift & Shift Lens Polycarbonate Bottom Lift & Shift Lens

CFL

Dimensions
A A B E D C

C B

(For mounting on concrete and steel on ly)

A 13 1/8 SWF 333 mm

B 22 1/2 572 mm

C 10 1/4 260 mm

D 11 9/16 294 mm

E 17 7/8 454 mm

55

lightwatt
lwf cfl

Features
Instant On and Instant Re-Strike The compact fluorescent lamps are on as soon as they are energized Good Color Compact fluorescent lamps have a CRI of about 82 Better Lumen Maintenance Compact fluorescent lamps have a flatter lumen maintenance curve Shielding of Lamp Image The refractor does a good job of breaking up the lamp image Appearance In comparison to all of the other CF highbays the Lightwatt just plain looks better. In many applications this could tip the scales in your favor

Ordering Information
Series Lightwatt LW Mounting j J-Box (damp location) Balanced Pendant (wet location); P (damp location) with cord option1 C Ceiling Thru-wire (wet location) B Pipe Wall Bracket (wet location) Stanchion Davit (wet location) S

Example:

LW
Series

P
Mount

084
Watts

4
Volts

A
Refractor

WH
Color

Wattage 042 064 084 Voltage 1 4

1 x 42W 2 x 32W 2 x 42W 120V 277V

Refractor A P Color WH GR
1

Acrylic Polycarbonate White Lektrocote Gray Lektrocote

Fast-Lock J-Box mounting-recessed J-Box requires installation of the included 1 1/2 extension ring. Note Lamp included. Note Options must be added as suffix to catalog number. Accessories must be ordered separately.

CFL

Dimensions

A
Surface J-Box by others

Top View

B
Mounting on a 4" square or octagonal box

B
Can be bal anced for mounting on swivel hangers, sloped ceilings, etc.

j-Box Mounting
A 12 1/4 311 mm B 14 3/4 375 mm

Pendant
A 14 356 mm B 14 3/4 375 mm

Ceiling Thru-Wire
A 14 1/4 362 mm B 14 3/4 375 mm

56

Features

utility worklight
bl400wl/bl400wlex

The BL400WL is ideal for use as a construction or work light. Die cast housing with protective white powder paint finish. Easy mounting box for 3/4 conduit. Cast safety hook included for hanging. 400 watt metal halide, 120/208/240/277 volt, HPF CWA ballast. Lamp included. Full wire guard to protect lamp during construction allows use of standard, stock metal halide lamps. UL listed for use in damp locations.

Ordering Information
Catalog Number BL400WL BL400WLEX Description Worklight Unit Pack, 400 watt MH, Multi-Tap w/ optic, lamp, & hook Worklight Unit Pack, 400 watt MH, Multi-Tap w/ optic, open rated lamp, & hook

For a complete list of options and accessories see pages 60 to 70.

Dimensions
9.2 4.5 3.0 2.6 5.0 23.5 8.8 8.0 4.5

13.2

57

superbay
unit pack

Features
Unit Packs include ballast housing, optic, and lamp, packaged in a single carton for convenience. Housing: two-piece, die cast aluminum. Corrosion resistant Lektrocote finish. All electrical components mounted directly to the ballast module for maximum heat dissipation and cooler operation. Optic: open 14 highbay (7 high BC reflector), enclosed 23 lowbay (LB1) or 22 acrylic (WA22). Adjustable light distribution lamp standard MH or HPS. 400 watt MH clear (coated with 22 acrylic). 400 watt HPS clear (coated with 22 acrylic). Quad-Tap ballast or new five tap (120/240/277/480V) ballast now available on Superbay Unit Packs. Exclusionary mogul base socket models also available. UL and CSA approved for 55C ambient operation. Suitable for damp locations.

Mogul Base

Ordering Information

Catalog Number BL400HVWHLB1uPL BL400H8BCEXuPL* BL400HVWHBCuPL* BL400H8WAEXuPL BL400HVBCEXuP* BL400HVBCEXuPL* BL250H8WHBIuPL* BL400HVWAEXuPL BL400H8WHBIuPL* BL400H8WHLB1uPL BL400H8WHWAuPL BL400S8WHBIuPL* BL400S8WHLB1uPL BL400S8WHWAuPL
* Optic is 7 high BC reflector

Wattage 400 400 400 400 400 400 250 400 400 400 400 400 400 400

Voltage Metal Halide Five Tap Quad-Tap Five Tap Quad-Tap Five Tap Five Tap Quad-Tap Five Tap Quad-Tap Quad-Tap Quad-Tap High Pressure Sodium Quad-Tap Quad-Tap Quad-Tap

Lamp Base Mogul Exclusionary Mogul Mogul Exclusionary Mogul Exclusionary Mogul Exclusionary Mogul Mogul Exclusionary Mogul Mogul Mogul Mogul Mogul Mogul Mogul

Lamp Included Lamp Included Lamp Included Lamp Included Lamp Included Less Lamp Lamp Included Lamp Included Lamp Included Lamp Included Lamp Included Lamp Included Lamp Included Lamp Included Lamp Included

58

packaging/flush mount
highbay/lowbay packaging options

Superbay

BL400H8WHBIUPL BL400H8WHLB1UPL

unit Pack Single Pack (standard) 60/Pallet job Pack 60/Pallet


BL400H8WHWAUPL

Tribay

Single Pack (standard) 30/Pallet

job Pack 30/Pallet

SuPERBAY FLuSHMOuNT

Features
Hubbell Lightings Flush Mount Kit allows you to mount the reflectors shown below flush to the bottom of a Superbay housing. This eliminates the need for the adjustable Optic Mounting Kit and securely attaches the reflectors to any Superbay housing. All Flush Mount Kit units are UL damp location listed.

Any Superbay Ballast Housing

+ =
CH-Ou 22 Aluminum

BL-FLuSH-MT-KIT

Any 22 or 25 Acrylic Reflector WA22 WW22 WA25

Any 19 or 23 Spun Aluminum Reflector from Tribay Series Eu Ou Eu69 Ou60

BL-WA22 22 Acrylic

BL-WA25 25 Acrylic

59

options & accessories


tribay matrix
OPTIONS

Options
Tribay
SW RO HG16 HG22 WA22 WW22 WD22 WA25 CHEu CHOu CHLM

Factory installed order with fixture by adding suffix. PLUGS ARE TWIST-LOCK TyPE AS MANUFACTURED By HUBBELL WIRING DEVICES. Suffix Description -AN -CFB -CXHLP(X) -CXHL(X) -DFP -EB -EX -F -GR -HA -LL -LRI -NMM -P -RO -QSS -QST -SLD -TRI Anodized Housing/Reflector Charcoal Filter Breather Cord, Hook/Loop & Plug w/ Slick-On Hanger Cord & Hook/Loop w/ Slick-On Hanger Dead Front Disconnect Encapsulated Ballast Exclusionary Socket Fusing Gray Lektrocote Finish High Ambient Shipped Less Lamp Lower Luminaire Retainer No Mounting Method High Strength Polycarbonate Refractor Remote Offset Quartz Standby System Quartz Standby with Time Delay Switch Level Dimming Top Luminaire Retainer

std

std

ACCESSORIES Field installed order as a separate item. Suffix BLA-C4HL CH-LLR CH-TLRX CHF CHFF CH-B CH-F-FuSE-KIT CH-Q CH-ENC FWG HG-FWG HG-ENC-XX HOOK/LOOP H3/4AL3/4 PHE PHS SY3 WA2-ENC WA22-CDL WA22-DLR WA-T WA25-DLR WA25-ENC WG Description 4' Cord Hook/Loop Lower Luminaire Retainer - 2' cable Top Luminaire Retainer Single Fusing Double Fusing (not for Canada) Wiring Box - no disconnect std std Tribay
HG16 HG22 WA22 WW22 WD22 WA25 CHEu CHOu CHLM SW RO

Accessories

Wiring Box - with disconnect (Quick Zone) Tempered Glass Lens Door Full Wire Guard for acrylic reflectors Full Wire Guard for glass reflectors Tempered Glass Enclosure for HG16 & HG22 Hook 3/4" NPS male Swivel Aligner - with box Die Cast Aluminum Power Hook Specification Grade Power Hook - with 30" cord Rugged Steel Power Hook Flat 1/8" Acrylic Lens Conical Drop Prismatic Lens Drop Lens Refractor Perforated Metal Top Enclosure Drop Lens Bottom Enclosure (for WA25 reflectors) Flat 1/8" Acrylic Bottom Enclosure for 25" reflectors Wire Guard WG16 WG23 WG23 WG23 WG23 WG25 WG19 WG19 WG29 WG-SW

std

60

options & accessories


superbay matrix

Options
Factory installed order with fixture by adding suffix. PLUGS ARE TWIST-LOCK TyPE AS MANUFACTURED By HUBBELL WIRING DEVICES. Suffix Description -AN -CFB -CXHL -CXHLP(X)SO -CXHLSO -DFP -EX -GR -LRI -NMM -P -QSS -QST -SLD -SO -TRI Anodized Housing/Reflector Charcoal Filter Breather Cord, Hook/Loop w/ Quick-On Hanger Cord, Hook/Loop & Plug w/ Slick-On Hanger Cord & Hook/Loop w/ Slick-On Hanger Dead Front Disconnect Exclusionary Socket Gray Lektrocote Finish Lower Luminaire Retainer No Mounting Method High Strength Polycarbonate Refractor Quartz Standby System Quartz Standby with Time Delay Switch Level Dimming Slick-On Thru Wire Outlet Box Top Luminaire Retainer

Superbay
EG LB1 LM AL BI Su SD RO

HG16 HG22 PA2 WA22 WW22 WA25 SW

std std

std std

Accessories
Field installed order as a separate item. Suffix Description Superbay
HG16 HG22 PA2 WA22WW22WA25SW EG LB1 LM AL BI Su SD RO

BLA-C4HL 4' Cord Hook/Loop B-LLR Lower Luminaire Retainer - 2' cable std std B-TLR Top Luminaire Retainer B-FLUSH-MT-KITAdapter Bracket for BL-WA22 or BL-WA25 BL-LR Tempered Glass Lens (for BI and SU, SD, AL 175 & 250W) BL-PK-ENC Flat 1/8" Acrylic Lens (for 175 & 250W MH) BL-QO Quick-On 3/4" Pendant Mount BL-SOF Slick-On Single Fusing BL-SOFF Slick-On Double Fusing (not for Canada) FWG Full Wire Guard for acrylic reflectors HG-FWG Full Wire Guard for glass reflectors HG-ENC Tempered Glass Enclosure for HG16 & HG22 HOOK/LOOP Hook 3/4" NPS male H3/4AL3/4 Swivel Aligner - with box PHE Die Cast Aluminum Power Hook PHS Specification Grade Power Hook - with 30" cord Sy3 Rugged Steel Power Hook WA2-ENC Flat 1/8" Acrylic Lens WA22-CDL Conical Drop Prismatic Lens WA22-DLR Drop Lens Bottom Enclosure WA25-DLR Drop Lens Bottom Enclosure (for WA25 reflectors) WA25-ENC Flat 1/8" Acrylic Bottom Enclosure for 25" reflectors WG Wire Guard WG16 WG23 WG16 WG23 WG23 WG25 SW-WG WG19 WG23 WG29 WG19 WG14 WG19 WG19

61

options & accessories


Options order with fixture by adding suffix Factory installed
Suffix -AN -CFB -C4HL -C6HL -C8HL -C10HL -C12HL -EB1 -EM -EX -F1 -F2 -F3 -F4 -F5 -FF -GR -LL -jP -LRI2 -NMM -P -PC -QSS -QST -SLD-1 -SLD-2 -SLD-3 -SO Description Tribay Superbay fig. 6, 7 Fig. # fig. 1 fig. 4 fig. 4 fig. 4 fig. 4 fig. 4 fig. 3 fig. 5 fig. 2 Anodized Housing/Reflector Charcoal Filter Breather (for enclosed reflectors only) 4' Cord, Hook/Loop - SO cord wired thru hook 6' Cord, Hook/Loop - SO cord wired thru hook 8' Cord, Hook/Loop - SO cord wired thru hook 10' Cord, Hook/Loop - SO cord wired thru hook 12' Cord, Hook/Loop - SO cord wired thru hook Encapsulated Ballast (for quiet operation) Emergency Quartz Lamp Socket Exclusionary Mogul Socket Fusing 120 volt Fusing 208 volt (not for Canada) Fusing 240 volt (not for Canada) Fusing 277 volt Fusing 480 volt (not for Canada) Fusing 347 volt Gray Lektrocote Finish on housing; replace -WH in catalog number Shipped Less Lamp (250, 350, 400 watt MH Electro-Reg and 600 watt HPS only) Job Pack - master carton packaging of ballast housing to reduce corrugated waste disposal; for shipment to jobsite only Lower Luminaire Retainer (installed) No Mounting Method - neither Slick-On nor Quick-On provided w/ luminaire; mounting method must be ordered as an accessory; option used for applications requiring mounting method supplied in advance of luminaire High Strength Polycarbonate Refractor Polycarbonate Refractor (LM only) Quartz Standby Quartz Standby with time delay Switch Level Dimming with 120V control Switch Level Dimming with 24V control Switch Level Dimming with 277V control Slick-On Thru Wire Outlet Box for 3/4" pendant or 1/2" or 3/4" side entry conduit SLICK-ON THRu WIRE OuTLET BOX, SINGLE FuSE (INCL.) for 3/4" pendant or side entry conduit 277V 347V 4 F SLICK-ON THRu WIRE OuTLET BOX, DOuBLE FuSE (INCL.) for 3/4" pendant or side entry conduit (not for Canada) 240V 480V 3 5

X3= -SOF (X3)

120V 1

X4= -SOFF (X4) -TRI(X)

208V 2

Top Luminaire Retainer - chain secures ballast housing to structure when additional safety precautions are required.Shipped in housing carton. Specify length (X), recommended maximum slack is 3"

1 Tribay ballasts available with the EB option: CH250E4-X-XX, CH250H8-X-XX, CH250W8-X-XX, CH320W8-X-XX, CH650W8-X-XX, CH400E4-X-XX, CH400H8-X-XX, CH400W8-X-XX, CH10H8-X-XX, CH10W8-X-XX. Consult with factory for any other ballast wattage/type. Minimum quantities and additional charges will apply. 2 Luminaire retainers/safety cables reduce risk of equipment falling NOTE: For specific applications, bottom enclosures may be required. For more information, please see specific lamp manufacturers data and the NEMA white paper Best Practices for Metal Halide Lighting Systems posted on the NEMA web site (www.nema.org). WARNING: Improper selection, installation, operation, servicing, removal, and disposal of lighting products may create serious hazardous including fires, explosions, shock, burns, cuts, impaired vision, falling objects, and environmental contamination. Reduce risks by using the guidance of licensed professionals throughout the product life cycle, and following individual product, component, and accessory safety instructions and labels. We offer this in the interest of safety for our customers, who may not be aware of the potentially high risk involved in the misuse of these products.

See pages 66-70 for detailed drawings.

62

(order separately) Suffix B-LLR1 B-TLR(6)1 B-TLR(10)1 B-TLR(12)1 B-TLR(16)1

Accessories

options & accessories


Description Tribay Superbay fig. 9 fig. 10 fig. 18 fig. 18 fig. 8 fig. 8 fig. 12 fig. 13 fig. 13 fig. 13 fig. 13 fig. 20 fig. 18 fig. 18 fig. 18 fig. 16 fig. 18 fig. 18 fig. 14 fig. 14 fig. 19 fig. 19 fig. 19 fig. 19 fig. 18 fig. 11 fig. 15 fig. 15 fig. 15 fig. 15 fig. 15 fig. 15 fig. 15 fig. 15 fig. 15 fig. 15 fig. 17 fig. 17 fig. 18 Fig. # Lower Luminaire Retainer - 2' cable secures reflector to ballast housing 6' Top Luminaire Retainer - chain secures ballast housing to structure when additional safety precautions are required 10' Top Luminaire Retainer - chain secures ballast housing to structure when additional safety precautions are required 12' Top Luminaire Retainer - chain secures ballast housing to structure when additional safety precautions are required 16' Top Luminaire Retainer - chain secures ballast housing to structure when additional safety precautions are required Bracket for mounting BL-WA22/WA22 or BL-WA25/WA25 reflector flush to the bottom of the Superbay ballast housing Tempered Glass Lens - thermal shock & impact resistant; gasketed on corrosion-resistant steel lens ring (not dust tight) required for 175, 250, 320 & 350 watt metal halide luminaires; for BI reflector only Tempered Glass Lens - thermal shock & impact resistant; gasketed on corrosion-resistant steel lens ring (not dust tight) required for 175, 250, 320 & 350 watt metal halide luminaires; for SU, SD & AL reflector only Flat 1/8" Acrylic Lens for PA2 16" reflector; required with 175, 250, 320 & 350 watt metal halide Quick-On 3/4" pendant mount Slick-On Thru Wire Outlet Box for 3/4" pendant or 3/4, 1/2 side entry conduit Slick-On Single Fusing (fuse not incl.) thru wire outlet box for 3/4" pendant or 3/4, 1/2 side entry conduit mount with single fuse holder Slick-On Double Fusing (fuses not incl.) thru wire outlet box for 3/4" pendant or 3/4, 1/2 side entry conduit mount with double fuse holder (not for Canada) Wiring Box with no electrical disconnect Wiring Box with electrical disconnect (Quick-Zone) Tempered Glass Lens Door for open 19" Tempered Glass Lens Door for open 23" Single Fuse Kit - 120, 277, 347V (fuses not included) Double Fuse Kit - 208, 240, 480V (fuses not included) (not for Canada) Lower Luminaire Retainer (for field installation) 6' Top Luminaire Retainer (for field installation) 10' Top Luminaire Retainer (for field installation) 12' Top Luminaire Retainer (for field installation) 16' Top Luminaire Retainer (for field installation) Full Wire Guard for acrylic reflectors Full Wire Guard for glass reflectors Flat Glass Bottom Enclosure for the HGE16 & HGO16 Flat Glass Bottom Enclosure for the HGE22 & HGO22 Superwatt Full Wire Guard with safety chain Flat Acrylic Bottom Closure for 22" prismatic acrylic reflector 22" Flat Acrylic Lens for WA acrylic reflector - 1/8" acrylic lens (40C maximum operating temperature with lens in place in reflector) Conical Drop Prismatic Lens for WA22 reflectors (40C operation) 22" Conical Acrylic Lens - conical drop lens for WA acrylic reflector (40C maximum operating temperature with lens in place in reflector) Drop Lens Refractor for WA22 reflectors (40C operation) Dropped Lowbay Refractor Lens - for 22" WA reflector (40C maximum operating temperature with lens in place in reflector) Drop Lens Refractor for WA25 reflectors Dropped Lowbay Refractor Lens - for 25" WA reflector (40C maximum operating temperature with lens in place in reflector) Flat Acrylic Bottom Enclosure for 25" prismatic acrylic reflectors Perforated Metal Top Enclosure for WA22 and WA25 reflectors 14" Wireguard - corrosion resistant, welded steel w/ center lamp access; can be used in combination with BL-LR-14 16" Wireguard - corrosion resistant, welded steel w/ center lamp access 19" Wireguard - corrosion resistant, welded steel w/ center lamp access 23" Wireguard - corrosion resistant, welded steel w/ center lamp access 29" Wireguard - corrosion resistant, welded steel w/ center lamp access Wire Guard for 16" highbay reflectors Wire Guard for 19" highbay reflectors Wire Guard for 23" highbay and 22" prismatic reflectors Wire Guard for 25" highbay reflectors Wire Guard for 29" highbay reflectors

BL-FLuSH-MT-KITADAPTER BL-LR-142 BL-LR-192 BL-PK-ENC2 BL-QO BL-SO BL-SOF BL-SOFF CH-B CH-Q CH-ENC-19 CH-ENC-23 CH-F CH-FF CH-LLR CH-TLR6 CH-TLR10 CH-TLR12 CH-TLR16 FWG HG-FWG HGENC16 HGENC22 SW-WG WA2-ENC WA2-ENC WA22-CDL WA22-CDL2 WA22-DLR WA22-DLR2 WA25-DLR WA25-DLR2 WA25-ENC WA-T WG-14 WG-16 WG-19 WG-23 WG-29 WG-16 WG-19 WG-23 WG-25 WG-29

1 Luminaire retainers/safety cables reduce risk of equipment falling. 2 Bottom enclosures are required unless lamps designated as suitable for open use are used.

See pags 66-70 for detailed drawings.

63

options & accessories


Fixture Cord Logic
Example: -C
Cord

HL

P
Plug

SO
Mounting Box

F
Fuse

4
Voltage

15A
Plug Amperage

Length Hook/Loop

CORD C LENGTH 4 16/3 SO cord, four feet long 6 16/3 SO cord, six feet long 8 16/3 SO cord, eight feet long 10 16/3 SO cord, ten feet long 12 16/3 SO cord, twelve feet long HOOK/LOOP HL Die Cast Fixture Hook with loop

FuSE BLANK No Fuse F Single Fuse mounted in FF

Slick On cover Double Fuse mounted in Slick On cover

VOLTAGE BLANK No plug required, only cord 1 2 3 4 5 C

closure

PLuG BLANK No plug required, only cord P Hubbell Twist Loc Plug MOuNTING BOX BLANK Standard Quick-On mounting SO

and hook/loop

and hook/loop 120v Hubbell Twist-Lock Plug 208v Hubbell Twist-Lock Plug 240v Hubbell Twist-Lock Plug 277v Hubbell Twist-Lock Plug 480v Hubbell Twist-Lock Plug 347v Canadian Hubbell Twist-Lock Plug

box Optional Slick-On mounting box (must be picked with fuse)

PLuG AMPERAGE BLANK 20 amp Hubbell Twist-Lock Plug 15A 15 amp Hubbell Twist-Lock Plug

See pages 66-70 for line drawings.

Popular Cord Set Options


C4HLP1 C4HLP4 C4HLP1-15A C4HLP4-15A

Dead Front Plug Offerings


DFP1

SO w/ Slick-On Hanger

F Single Fuse

F2 Double Fuse

X Voltage 1 4 5 1 4 5 1 4 5 1 4 5 (120V) (277V) (480V) (120V) (277V) (480V) (120V) (277V) (480V) (120V) (277V) (480V)

Catalog Number DFP1 DFP4 DFP5 DFPSO1 DFPSO4 DFPSO5 DFPSOF1 DFPSOF4 DFPSOF5 DFPSOFF1 DFPSOFF4 DFPSOFF5

DFP DFP DFP DFP DFP DFP DFP DFP DFP DFP DFP DFP

SO SO SO SO SO SO SO SO SO

F F F F F F

F F F

1 Dead Front Plug includes Cord, Loop and Dead Front Disconnect Plug with Quick-On Hanger 15" SO cord factory wired to fixture; order with PHS-XXXL (see mounting accessories). 2 Not for Canada.

NEMA Configurations

Voltage Description

120 208 240 277 480 120 208 240 277

Plugs1 Receptacles NEMA # Plug # NEMA # 20 Amp Plugs & Receptacles 2 pole, 3 wire grounding L5-20P 2311 L5-20R 2 pole, 3 wire grounding L6-20P 2321 L6-20R 2 pole, 3 wire grounding L6-20P 2321 L6-20R 2 pole, 3 wire grounding L7-20P 2331 L7-20R 2 pole, 3 wire grounding L8-20P 2341 L8-20R 15 Amp Plugs & Receptacles 2 pole, 3 wire grounding L5-15P 4720C L5-15R 2 pole, 3 wire grounding L6-15P 4570C L6-15R 2 pole, 3 wire grounding L6-15P 4570C L6-15R 2 pole, 3 wire grounding L7-15P 4770C L7-15R

1 CSA certified. NOTE: All plugs are manufactured by Hubbell Wiring Device Division.

64

Mounting Accessories
Catalog # BLA-C4HLP-1 BLA-C4HLP-4 BLA-C4HLP1-15A BLA-C4HLP4-15A HOOK/LOOP1 H3/4AL3/41 PHE-XXX1

options & accessories

(order separately) Plugs are Twist-Lock type as manufactured by Hubbell Wiring Devices. Description 4' Cord, Hook/Loop and 120V 20A Twist-Lock Plug 4' Cord, Hook/Loop and 277V 20A Twist-Lock Plug 4' Cord, Hook/Loop and 120V 15A Twist-Lock Plug 4' Cord, Hook/Loop and 277V 15A Twist-Lock Plug Hook - cast aluminum 3/4" NPS male; includes safety screw; converts to Loop with strap included Swivel Aligner - complete with box for thru wiring; all hubs tapped for 3/4" conduit - 25 swivel Die Cast Aluminum Power Hook with 20A Twist-Lock Receptacle ceiling or 3/4" pendant mount, with 3/4" side entry for thru wiring 15" Cord, Hook/Loop & Twist-Lock Plug (20 amp) included (for voltage replace XXX with 120, 208, 240, 277, 347, or 480) As above, except cord, loop & plug not included (for voltage replace XXX with 120, 208, 240, 277, 347, or 480) Specification Grade Power Hook - 30" cord dead front plug & receptacle with isolated wiring chamber; ceiling or 3/4" pendant mount, with 3/4" side entry for thru wiring; special safety feature locks Hook/Loop onto bottom hook (for voltage replace XXX with 120, 208, 240, 277, 347, or 480) Specification Grade Power Hook - dead front receptacle with isolated wiring chamber; ceiling or 3/4" pendant mount, with 3/4" side entry for thru wiring; Cord, Hook/Loop and Dead Front Plug not included, must be ordered with luminaire (for voltage replace XXX with 120, 208, 240, 277, 347, or 480) Rugged Steel Power Hook with 20A Twist-Lock Receptacle - pendant or surface mount, 3/4" thru wiring capability; 30" Cord, Hook/Loop and Plug (20 amp) included (for voltage replace XXX with 120, 208, 240, 277, 347, or 480) Porta-Hook includes integral mounting hook and 20A Twist-Lock Receptacle; 3/4" knockouts on top and two sides; Cord, Hook/Loop and Plug (20 amp) not included (for voltage replace XXX with 120, 208, 240, 277, 347, or 480)

PHE-XXX-L2 PHS-XXX

PHS-XXX-L1,3

SY3-XXX-2 SY3-XXX-L2

1 CSA certified. 2 Cord, Hook/Loop and Plug must be added to fixture as option, example: -C2HLP4. 3 Cord, Hook/Loop and Dead Front Plug must be added to fixture as option, example: -DFP4. NOTE: Cord used with above accessories is 16/3 SOWA 105C NEMA configurations.

See pages 66-70 for line drawings.

65

options & accessories


Options Details

FIG. 1
CHARCOAL FILTER BREATHER TRIBAY/SuPERBAY

-CFB

FIG. 2
EXCLuSIONARY MOGuL SOCKET TRIBAY/SuPERBAY

-EX

FIG. 3
ENCAPSuLATED BALLAST TRIBAY

-EB

FIG. 5 FIG. 4
CORD/HOOK/LOOP TRIBAY EM - EMERGENCY QuARTZ LAMP SOCKET QSS - QuARTZ STANDBY QST - QuARTZ STANDBY WITH TIE DELAY TRIBAY/SuPERBAY

-EM/-QSS/-QST

-CXHL

FIG. 6
LOWER LuMINAIRE RETAINER (INSTALLED) LARGE REFLECTOR TRIBAY

FIG. 7
LOWER LuMINAIRE RETAINER (INSTALLED) SMALL REFLECTOR TRIBAY

-LRI

-LRI

66

Accessories Details

options & accessories

FIG. 8
SINGLE/DOuBLE FuSE KIT TRIBAY

CHF/CHFF

FIG. 9
WIRING BOX WITH NO ELECTRICAL DISCONNECT TRIBAY

FIG. 10
WIRING BOX WITH ELECTRICAL DISCONNECT (QuICK-ZONE) TRIBAY

CH-B

CH-Q

FIG. 11
PERFORATED METAL TOP ENCLOSuRE TRIBAY

WA-T

67

options & accessories


Accessories Details
FIG. 12
LOWER LuMINAIRE RETAINER (FOR FIELD INSTALLATION) TRIBAY

CH-LLR

FIG. 13
TOP LuMINAIRE RETAINER (FOR FIELD INSTALLATION) TRIBAY

CH-TLR

FIG. 14
CONICAL DROP PRISMATIC LENS FOR WA22 REFLECTOR TRIBAY/SuPERBAY

WA22-CDL

68

Accessories Details Features

options & accessories

FIG. 15
WIRE GuARD FOR HIGHBAY REFLECTORS TRIBAY/SuPERBAY

FIG. 16
SuPERWATT FuLL WIRE GuARD WITH SAFETY CHAIN

WG-XX

SW-WG

FIG. 17
TEMPERED GLASS LENS SuPERBAY

FIG. 18
TEMPERED GLASS LENS FLAT ACRYLIC BOTTOM ENCLOSuRE TRIBAY/SuPERBAY

BL-LR

-ENC

FIG. 19
DROP LENS REFRACTOR TRIBAY/SuPERBAY

DLR/DLR2

FIG. 20
FuLL WIRE GuARD FOR ACRYLIC REFLECTORS TRIBAY/SuPERBAY

FWG

FuLL WIRE GuARD FOR GLASS REFLECTORS TRIBAY/SuPERBAY

HG-FWG

69

options & accessories


Mounting Accessories Details
3516" (84 mm) 438" (111mm) 4" (102 mm)

34" (19 mm) threaded

HOOK/LOOP

SWIVEL ALIGNER
2 38" (60 mm)

H3/4AL3/4

112" (38 mm)

7716" (189 mm)

7" (178 mm) 6" (152 mm)

(303 mm)

111516"

34" (19 mm)

38" (10 mm)

TWIST-LOCK RECEPTACLE POWER HOOK

PHE-XXX

5" (127mm)

7716" (189 mm) 111516" (303 mm)

SPECIFICATION GRADE POWER HOOK


514" (133 mm) 238" (60 mm)

PHS-XXX

414" (108 mm) 3316" (81 mm)

7" (178 mm)

SY3-XXX-L
PORTA-HOOK

70

Features
Tribay RO Series consists of a ballast module and a remote reflector/refractor mounting module. It accepts any of the Tribay optical systems. Ideal for applications requiring low profile luminaires or remote mounting of ballasts. For highbays, lowbays, prismatic refractors, aisle lighters, and enclosed and gasketed fixtures. All of the electrical and mechanical features and benefits of Tribay luminaires are retained in the Tribay RO. Suitable for damp locations. you must order three items. Ballast housing, optical assembly and remote optical mounting bracket, e.g., CH-OU, CH-25-H-8-M-RO, RO-25-H-OU

remote

tribay remote

Mogul Base

CH
Series

OU
Optical Assembly

CH
Series

25
Watts

H
Ballast

8
Volts

M
Mounting

RO
Remote

Optical Assembly

Series Tribay Series CH Optical Assembly 19 Open highbay reflector Ou 19 Enclosed highbay reflector Eu 23 Open highbay reflector Ou60 23 Enclosed highbay reflector Eu60 29 Lowbay optics (750W max) LM Superwatt optics (450W max) SW 22 Clear prismatic reflector (750W max) WA22 22 Opaque prismatic acrylic reflector (750W max) WW22 22 Diffuse prismatic reflector (750W max) WD22 WA25 25 Clear prismatic acrylic reflector (1000W max)

Ballast Assembly
Series Tribay Series CH Wattage 250W 25 32 320W 35 350W 400W 40 45 450W 600W 60 75 750W 1000W 10 Ballast/Lamp System W Pulse Start CWA Electro-Reg (lamp included) E MH - Standard PLA H HPS, low loss Mag-Reg L M HPS, Mag-Reg HPS Standard CWA, AL, HPS S HPS, CWI (Canada) F MH, CWI (Canada) D Voltage 120V 1 208V 2 240V 3 277V 4 480V 5 Tri-Tap 120/277/347V (not available on Electro-Reg) 6 600V (Isolated secondary only) 7 Quad-Tap 120/208/240/277V 8 (not available on Electro-Reg) Less ballast and cap (250 & 400W only) O 220/240V 50Hz (HPS and MH only) E 347V F Mounting Method Quick Zone Electrical disconnect - wiring box shipped D with fixture Quick Zone Electrical disconnect - wiring box not E shipped with fixture (wiring box must be shipped as accessory - CH-Q) Less wiring box (wiring box shipped as accessory - CH-B) L With wiring box (standard construction) M Remote Offset RO Remote Ballast Housing

Remote/Offset Optical Mounting Bracket


Catalog Number RO-XX1-X2-XX3
1 2 3

Weight lbs. (kg) 5 (2.3)

Substitute fixture wattage from ballast assembly chart. Substitute ballast/lamp letter designation from ballast assembly chart Substitute optical order code from optical assembly chart

For a complete list of options and accessories see pages 60-70.

Dimensions
Ou/Eu Ou60/Eu60 LM SW WA22, WD22, WW22 WA25 B 10 3/4 273 mm 10 3/4 273 mm 10 3/4 273 mm 10 3/4 273 mm 10 3/4 273 mm 10 3/4 273 mm C 23 5/8 600 mm 26 3/8 670 mm 26 1/2 673 mm 22 3/4 578 mm 24 3/4 629 mm 25 1/4 641 mm

Ballast Assembly

A 13 1/2 Ballast 343 mm

Optical Assembly 71

remote
superbay remote

Features
Superbay RO Series consists of three parts detailed below. To make a complete unit, you must order an optical assembly, a ballast assembly and a remote/offset optical mounting bracket. It accepts any of the Superbay optical systems. Ideal for applications requiring low profile luminaires or remote mounting of ballasts. For highbays, lowbays, prismatic refractors, aisle lighters, and enclosed and gasketed fixtures. All of the electrical and mechanical features and benefits of Superbay luminaires are retained in the Superbay RO. Up to 55C ambient. Suitable for damp location.

Mogul Base

Ordering Information
BL
Series

AL
Optical Assembly

BLA
Series

250
Watts

H
Ballast

8
Volts

WH
Color

RO
Remote

Optical Assembly
Series Superbay Series BL Optical Assembly Aisle Lighter AL 14 Spun Aluminum Reflector BI Enclosed and Gasketed EG 23 Lowbay Optics LB1 16 Clear Acrylic Reflector PA2 19 Reflector with downlight SD 19 Reflector with uplight Su 29 Lowbay LM 22 Acrylic Reflector WA WW 22 Opaque Acrylic Reflector

Ballast Assembly
Series BLA Wattage 150 175 200 250 320 350 400 450 Source H S W E Voltage 1 2 3 4 5 6 8 F Color WH GR Remote RO Superbay Series 150W Pulse Start MH or HPS 175W MH or Pulse Start MH 200W Pulse Start MH only 250W MH, Pulse Start MH, or HPS 320W Pulse Start MH only 350W Pulse Start MH or Electro-Reg 400W MH, Pulse Start MH, HPS, or Electro-Reg 450W Pulse Start MH only Metal Halide High Pressure Sodium Pulse Start Metal Halide Electro-Reg (40C) 120V Electro-Reg only 208V Electro-Reg only 240V Electro-Reg only 277V Electro-Reg and Linear Reactor 480V Electro-Reg and Linear Reactor Tri-Tap 120/277/347V (not available on Electro-Reg) Quad-Tap 120/208/240/277V (not available on Electro-Reg) 347V White (standard) Gray (optional) Remote Ballast Housing

Remote/Offset Optical Mounting Bracket


Catalog Number RO-XX-X-BL RO-40-H-BL
Note Note

Application All HPS and 175W, 250W and 320W MH 350W, 400W, 450W and 750W MH only

Weight lbs. (kg) 5 (2.3) 5 (2.3)

Complete with hook/loop, 36 cord, and 15A Twist-Lock plug. Do not substitute for Xs.

For a complete list of options and accessories see pages 60-70.

Note MV lamp will operate on MH ballast. Note Linear Reactor Pulse Start ballast available, 277V only - Consult factory. Note Options must be added as suffix to catalog number. Accessories must be ordered separately.

Dimensions
Ballast Assembly
LM PA2 WA22 WW22 WA25

Optical Assembly
B 26 1/2 673 mm 20 1/4 - 22 1/2 514 mm - 571 mm 23 1/4 - 25 1/2 591 mm - 648 mm 23 3/4 - 26 603 mm - 660 mm AL-SD-Su BI EG LB1 B 21 - 23 1/4 533 mm - 591 mm 19 3/4 - 22 502 mm - 559 mm 20 1/4 514 mm 24 1/2 622 mm

A 10 1/2 Ballast 267mm

72

Features

dimming/wiring systems

lightbat g2

Reduces energy consumption by 40 to 50% For use with CWA ballast only, reduces lamp power up to 50% Microprocessor controlled (exclusive to Hubbell): Sensor adjustments are fully automatic for the life of the product; use of solid state switching near zero crossing eliminates harmful high capacitor inrush currents; integrated self-diagnostics significantly reduces installation and test time Lamp current monitoring for guaranteed 15 minute lamp warm up after lamp has started Sensor lens is 2 to 3 times more powerful than any competitive product on the market Lights Bright Timer Settings: 1, 2, 4, 8, 32, 64 minute and 5 second test mode Laser tool significantly improves sensor alignment accuracy and speeds installation Uses Myzer Port connector system Minimum operating temperature -35C Dimensions: 13 1/4 H x 5.5 W x 2.6 D UL and C-UL; warranty for 5 years Dim capacitor and PIR sensor lens required

Ordering Information
Catalog Number -MP LB-1 LB-2 LB-3 Description Myzer Port Myzer Port, Industrial Option Lightbat G2 Controls the following lamp types and wattages at 65C: 175W MH; 175W, 200W Pulse Start MH Controls the following lamp types and wattages: 250W, 320W, 350W, 400W MH at 65C; 250W, 320W, 350W, 400W, 450W Pulse Start MH at 65C; 250W HPS at 65C; 400W HPS at 55C Controls the following lamp types and wattages at 55C, 30 minute lamp warm up cycle: 1000W, 1500W, 1650W MH; 750W, 100W Pulse Start MH; 600W, 1000W HPS

Lightbat G2

Myzer Port Dual Level HID Control System Installation


hid fixture dual-level control (lb-x)

dim cap capacitor myzer port (mp)


ss switch power supply control electronics sensor electronics

pir lens (lb-lens xx)

pir sensor

Dimensions

13 1/4"

73

dimming/wiring systems
lightbat g2
THE LIGHTBAT DuAL-LEVEL CONTROL SYSTEM
The Lightbat Dual-Level Control System is an integrated digital HID dual-level switching controller and sensor. One sensor comes with every fixture and is plugged into a Myzer port connector. Complex wiring and setup is eliminated, and can thereby reduce the total installed cost (materials and labor) by over 50%. Energy savings can be maximized with sensors at every fixture. Only Hubbells new advanced dual-level switching system will reliably operate with short, one-minute timer settings. This is a key requirement to reduce energy by over 40%, even in the busiest of warehouses. The Dual-Level Control features the following: One sensor per fixture for maximum savings Best sensing performance Lowest installed cost for combination dual-level switching and motion sensing Options available for easy interface to photocell controls

MYZER PORT IS ORDERED AS AN INSTALLED OPTION (-MP)

Superbay

Tribay

Tribay Superwatt

Range Diagrams
Lens 15
AISLE LENS, 12' TO 20' (MAX) MOuNTING HEIGHT ABOVE FLOOR
Length Sensor Height Abo Floor ve 20' Width

Lens 07
AISLE LENS, 25' TO 50' (MAX) MOuNTING HEIGHT ABOVE FLOOR
Length Sensor Height Abo Floor ve 30' Width

30'

20'

10'

0'

10'

20'

30'

4.6' 0' 4.6' 24'20' 10' 0' 10' 20' 4' 2 4.8' 10' 0' 10' 4.8'

Lens 0806
AISLE LENS, 12' TO 30' (MAX) MOuNTING HEIGHT ABOVE FLOOR
Length Sensor Height Abo Floor ve 30' Width Length

Lens 10
AISLE LENS, 16' TO 35' (MAX) MOuNTING HEIGHT ABOVE FLOOR
Sensor Height Abo Floor ve 35' Width

24' 20' 10'

0'

10' 20' 24'

4.8' 10'

0'

10' 4.8'

74

35'30'

20'

10'

0'

10'

20' 30'35'

8' 0'

8'

Hubbells Industrial products come in many shapes, sizes, wattages and levels of performance. Beyond the efficient delivery of light, we have a number of value-added technologies that work to make your system last longer, be more energy efficient, reduce maintenance and control your light usage more effectively.

Electronic Electro-Reg
V-SPEC

PulseSmart

Electro-Reg
EL Series

EPAct
2005

75

EPAct
2005
LARGE CHOICE OF BALLAST TYPES VIRTUALLY ALL HUBBELL INDUSTRIAL FIXTURES ARE EPAct COMPLIANT. THIS INCLUDES THREE CLASS I, DIV. 2 FIXTURES. FOR MORE INFORMATION, VISIT

www.hubbelllighting.com/epact/

The Energy Policy Act of 2005 establishes a long-range energy policy to combat the nations growing energy crisis. Effective January 1, 2006, through December 31, 2007, the U.S. government is offering substantial, accelerated tax incentives as a reward for installing or retrofitting energyefficient lighting, HVAC and/or building envelope technologies in qualifying applications. Lighting, a critical component of energy use today, represents 40% of the average commercial buildings electric bill. Energy-efficient upgrades reduce energy consumption and operating costs by 30 to 50% and often pay themselves back within months. The true benefit of EPAct 2005 is that it allows a larger portion of the capital investment to be depreciated in the first year. Generally, lighting retrofit investments are amortized over the life of the system, but EPAct 2005 allows a larger portion to be deducted immediately. EPACT 2005 QUALIFICATIONS TO QUALIFY FOR THE EPACT 2005 TAX DEDUCTIONS, A COMMERCIAL BUILDING PROPERTY MUST: Be located in the U.S. and fall within the scope of ASHRAE/IES Standard 90.1-2001; and Receive an upgrade/installation of: (1) interior lighting system, or (2) heating/cooling/ventilation/hot water systems, or (3) building envelope that was put in service between Jan. 1, 2006 and Dec. 31, 2007 Be certified as being an energy-efficient property, defined as one that has 50% reduction in the total annual energy and power costs of a building satisfying ASHRAE/IES Standard 90.1-2001.

EPACT 2005 CLAIMS BEFORE CLAIMING THE EPACT 2005 TAX DEDUCTION, YOU MUST: Have the plans and actual in-place construction reviewed by qualified, third-party inspectors; and Have energy savings determined by software certified by the Department of Energy as meeting criteria of consistency and accuracy; and Obtain a certification, as determined by the IRS, that the required energy savings will be achieved.

THE QUALIFIED, THIRD-PARTY INSPECTORS: Are not related (do not have an employer/employee relationship) to the taxpayer claiming the deduction; and Are engineers or contractors who are properly licensed as professional engineers or contractors in the jurisdiction in which the building is located; and Represent in writing to the taxpayer that they have the requisite qualifications to provide the certification required and/or to perform the inspection required. THERE ARE TWO TYPES OF TAX DEDUCTIONS YOU CAN CLAIM: Whole Tax Deduction Interior lighting, HVAC/hot water and building envelope systems One-time deduction up to $1.80/sq.ft. if ASHRAE/IES Standard 90.1-2001 is exceeded by 50% Partial Tax Deduction Not all systems achieve 50% improvement over ASHRAE/IES Standard 90.1-2001 It is possible to upgrade only portions of a building to higher efficiency lighting, with the deduction based on upgraded space square footage One-time deduction of $0.30 to $0.60/sq.ft. for lighting with 25-40% improvement over ASHRAE/IES Standard 90.1-2001
SOLUTIONS There are more advantages to a lighting upgrade than reducing energy costs and conserving energy good lighting can actually increase your bottom line. A lighter office environment can improve employee morale and reduce absenteeism. Aesthetically pleasing lighting can highlight product features in retail environments, encouraging lingering, buyer confidence and impulse sales. Proper lighting in manufacturing buildings can boost quality control and speed productivity. Improved lighting in warehouses can reduce errors and improve safe

TO RECEIVE THE TAX DEDUCTION, THE DEDUCTION MUST: Not exceed the cost of the upgrade, including materials, labor and design; and Be taken in the taxable year the property or upgrade is placed in service (either 2006 or 2007); and Be calculated based on the square footage of the upgraded building. Up to $1.80/sq.ft. for energy-efficient property Up to $0.60/sq.ft. each for interior lighting, HVAC/hot water and building envelopes TO CLAIM THE TAX DEDUCTION, YOU MUST BE: The owner or entity who paid to have the commercial building constructed or renovated The party primarily responsible for designing the publicly owned property

76

ELECTRONIC E-REG
Electronic E-Reg is a new kind of HID ballast with microprocessor-based technology that delivers a genuine, quantum leap in metal halide performance. Performance measured by extraordinary, unprecedented lumen maintenance capabilities means huge opportunities for operating cost reductions, both through energy savings and lower maintenance requirements. In addition, Electronic E-Reg also helps turn color shift, lamp blackening and lack of control into long-gone problems of the past. In applications where fluorescent options such as T5/HO are beginning to provide an HID alternative, users looking for a positive cost/benefit equation now have more choices and more ways to enjoy the rewards of better lighting. REVOLUTIONARY TECHNOLOGY DELIVERS REVOLUTIONARY VALUE With the introduction of Electronic E-Reg electronic ballasts for HID systems, Hubbell Industrial has established totally new benchmarks for performance and cost savings. The key to understanding the true value of this innovation is something called "lumen maintenance," or the lamp/ballast systems ability to minimize light output depreciation over the life of the lamp. Conventional HID systems magnetic ballasts driving probe start metal halide lamps typically experience a 50-60% fall-off in light output over the published life of the lamp. This fall-off can lead to excessive maintenance costs due to the need for frequent re-lamping, and inefficient energy usage throughout the life of the system. Electronic E-Reg changes the rules by delivering a 30-50% improvement in lumen maintenance over these conventional systems. By maintaining higher light levels across the entire published life of the lamp, the system delivers significant value to the end user in three key ways:

Lumen Maintenance Comparison


100%

86%
% INITIAL LUMENS

86% 75%

72%

64%
58%
Pulse Start MH with Dynavision

30-50% IMPROVED LUMEN MAINTENANCE LEADS UP TO 50% LESS LAMP REPLACEMENT COSTS 56% MORE LUMENS ENABLES THE USE OF UP TO 36% FEWER FIXTURES 36% FEWER FIXTURES LEADS TO 41% ENERGY SAVINGS ANNUALLY! 10-YEAR OVERALL COST OF OWNERSHIP REDUCED UP TO 36%

44%

Pulse Start MH magnetic ballast Probe Start MH magnetic ballast

30%
0 4 8 12 OPERATING HOURS (1000s) 16 20

77

ELECTRONIC E-REG
IMPROVED LUMEN MAINTENANCE = LESS LAMP MAINTENANCE Most lighting systems are designed on the basis of mean oraverage light output of the lamp. For metal halide (MH) lamps, this mean light output, as measured in lumens, defined at 40% of the lamps rated life. Since most medium wattage MH lamps are rated at 20,000 hours of lamp life, mean lumens are advertised at 8,000 hours of lamp life. As lumens fall off after the 8,000 hr. design point, the lighting level for many applications may become unacceptable, resulting in the need for re-lamping significantly prior to reaching the 20,000 hr. rated life of the lamp. Because of Electronic E-Regs relatively flat lumen depreciation characteristic, (i.e., better lumen maintenance), early re-lamping is unnecessary, resulting in a more cost-effective lighting system. In the example below, consider identical installations with 400 fixtures: one with magnetic ballasts where lamps are replaced at 12,000 hours, and a second where lamp life is extended to 18,000 hours.

Conventional Magnetic Pulse Start


In this example, Electronic E-Reg would save on average $10 per fixture, per year, just in reduced maintenance costs! The assumption was made that an equal number of fixtures were used. Next, consider the total consequences of producing more light, longer, with fewer fixtures and discover its true advantage.

Electronic E-Reg
400 5,000 18,000 $10,000 (@ $25/lamp) $10,000 (@ $25/fixture) 2 $ 40,000

Number of Fixtures Annual burn hours Lamps replaced at (hrs.) Lamp cost per each re-lamping Fixture cleaning & lamp replacement labor Number of replacements in 10 years Total 10-year cost of lamp changes

400 5,000 12,000 $10,000 (@ $25/lamp) $10,000 (@ $25/fixture) 4 $80,000

10-YEAR LAMP MAINTENANCE SAVINGS = $40,000!

MORE MAINTAINED LUMENS = FEWER FIXTURES

Benefits of Fewer Fixtures


Faster Installation Lower Material Costs Lower Labor Costs Lower Maintenance Costs Lower Energy Costs
EQUIVALENT LIGHT LEVELS: 400W Probe Start 150 Fixtures 400W Electronic E-Reg 96-100 Fixtures

Lower Total Cost of Ownership

A 400W Electronic E-Reg system produces up to 56% more mean lumens over conventional probe start systems using the same wattage lamps. Taking advantage of this performance benefit, the overall fixture count can be

reduced by up to 36% without sacrificing light levels. Plus, fewer fixtures also have a dramatic impact on both energy and maintenance costs, leading to significantly lower overall operating costs.

78

Electronic E-Reg Features


Microprocessor technology High frequency operation True constant wattage 320/350/400 Tri-Wattage IntelliVolt 200-277V 50/60 Hz Integral 120V quartz tap and relay, 250W

Benefits and Advantages


Lower operating and maintenance costs Fewer fixtures Energy savings Fewer SKUs Less chance for error Ease of change over to different wattage lamps Standby-lighting ready No special orders No special relay or control required Continuous dimming down to 50% lamp power Additional energy savings through daylight harvesting and occupancy sensing Greater reliability, flexibility and application opportunities Safety

MORE ABOUT...STANDBY LIGHTING VERSATILITY Electronic E-Regs 120-volt output is designed to operate one quartz (incandescent) standby lamp up to 250W. The quartz lamp on or off modes are determined by the HID lamps specific operating conditions. Once the HID lamp strikes, the quartz lamp automatically switches off when the HID lamp reaches 50% power. CONTROLLABILITY Electronic E-Reg is dimmable down to 50% of nominal lamp power, with no noticeable loss in color characteristics. With 0-10V dimming, and compatible with a host of products from most control manufacturers, Electronic E-Reg brings new flexibility and energysaving strategies, such as daylight harvesting and occupancy sensing, to applications in the industrial, educational, government, hospitality, commercial and retail sectors.

0-10V dimming with automatic 15-minute warm up 55C ambient rating Lamp end-of-life protection

APPLICATION SPECIFICATIONS
Pulse Start Metal Halide Min Input Volts Lamp Data Start Temp. No. Watts (F/C) 1 320 -20/-30 200 to 277 Catalog Number Listings Line Cur. (A) Input Ballast Power Factor ANSI (W) 345 345 1.0 Max. THD % Min. PF % DIP Switch Settings
9.2 bracket end-to-end length 3.7 Hot spot measurement location at screw 8.0 2.3 4.0

320-Watt Lamp, ANSI Code M132/M154 IZTEMH4003PS 1.8 1.3 15 90


ON

2.6 3.1875 slot

4.4

350-Watt Lamp, ANSI Code M131 1 350 -20/-30 200 to 277 400 -20/-30 200 to 277 IZTEMH4003PS 1.9 1.4 2.2 1.6 375 375 430 430 1.0 15 90
ON

Optional junction box

400-Watt Lamp, ANSI Code M135/M155 1 IZTEMH4003PS 1.0 15 90


Preset at Factory

5mm mounting holes (4) for #10 screws 4.4 mounting dimensions Integral mounting brackets

8.8 mounting dimensions

Fully enclosed extruded aluminum housing with white finish

ON

NOTE: These specifications apply to operation of pulse start metal halide lamps with quartz one-tube construction only. For operating compatibility with ceramic one-tube lamps consult Hubbell Industrial.

Dip switches are on in the down position

DIP switch access for lamp wattage selection

DIMMING FEATURE With 0-10V interface, the Electronic E-Reg electronic ballasts offer the capability to dim the lamp by lowering the wattage lamp, reducing energy consumption of the light fixture by up to 50%.This interface can be used with either a commercially available 0-10V dimming control, a 0-10V DC power supply, or with a switch. An open switch provides full lamp power and a closed switch, short-circuiting the 0-10V wires, yields 50% lamp power. Control devices such as relays and occupancy sensors may also be used. A potentiometer may also be used. However, the value of the potentiometer is dependent on the number of ballasts connected. Consult Hubbell Industrial for guidance. In accordance with the requirements of the HID lamp manufacturers and NEMA, the dimming feature includes a time delay to allow the HID lamp to warm up for 15 minutes at full power before the lamps will be allowed to dim, regardless of the level of the 0-10V signal.
Violet 0-10v Interlace Wires Gray Potentiometer Switch 0-10V Dimming Control

WIRE INFORMATION

Wire Color Black White Green Red Blue Yellow (2) Violet Grey

Function Input Power Input Power Ground Lamp Eyelet Lamp Screwshell 120V Lamp Output 0-10V Dimming (+) 0-10V Dimming (-)

BALLAST

OR

OR

All lead lengths are 11.0 + / - 1.0 and are 0.5 pre-stripped.

79

EL SERIES
ELECTRONIC BALLASTS
EL SERIES COMBINES HIGH PERFORMANCE FIXTURE OPTICS AND ELECTRONIC BALLASTS Combining decades of Hubbell Industrial optic design expertise, delivering more light to work areas with new electronic pulse start ballasts and safe, productive workplaces is now possible with the beneefits of more lumens per lamp at lower energy costs.

EL fixtures meet the needs of virtually any system from highbays to lowbays, in acrylics and spun aluminum.

Highbays Electronic 14" spun aluminum Electronic enclosed & gasketed Electronic 19" uplight Electronic 19" downlight only Electronic 19" aisle lighter Lowbays Electronic 23" bottom lens refractor Glass Electronic 16" glass refractor Electronic 22" glass refractor Acrylic Electronic 16" acrylic refractor Electronic 22" acrylic refractor Electronic 25" acrylic refractor Electronic Superwatt
80

BI see page 16 EG see page 19 SU see page 20 SD see page 20 AL see page 20 LB1 see page 28

Electronic 29" bottom lens enclosure LM see page 29 HGX16 see page 37 HGX22 see page 37 PA2 see page 40 WA22 see page 41 WA25 see page 42 CH-SW see page 43

Electronic 22" diffuse acrylic refractor WW22 see page 41

ELECTRO-REG
DOUBLE THE LAMP LIFE. HOW DOES THE ELECTRO-REG SYSTEM DO IT?

BALLAST SYSTEM ADVANTAGE


HIGHER LUMEN MAINTENANCE The lumens produced by metal halide lamps depreciate over time. Some of that depreciation is caused by how the ballast system controls the ignition and operating currents supplied to the lamp and the waveforms of these currents. Our Electro-Reg ballast system has been developed to greatly enhance control of these currents. Over millions of operating hours the results of that control are outstanding. Shielding the lamp from the direct effects of the ballast capacitor charging and discharging is critical. If the lamp is in series with the capacitor, as with a CWA or Pulse Start CWA, the lamp is subjected to a surge of current when the capacitor discharges. The capacitor also draws current away from the lamp as it charges. This over-driving and under-driving of the lamp is one of the biggest causes of loss of light as the lamp ages.

In its simplest terms, the Electro-Reg ballast system treats the lamp as it should be treated. First, weve designed the Electro-Reg ballast system with an isolated, three-coil design. One coil handles the incoming supply voltage, one coil regulates the energy available to the lamp and the final coil is connected to the lamp. Three isolated coils do one thing very well. They isolate and shield the lamp from the distorted current characteristics resulting from normal capacitor charging and discharging. And help to shield the lamp from voltage fluctuations inherent in the power supply.
PRIMARY COIL (SUPPLY) CAPACITOR COIL SECONDARY COIL (REGULATING) (LAMP)

The second benefit comes from our patented ignitor. Igniting a lamp using high voltage is just a more effective way to operate and results in smoother starting and warm-up. This means less electrode damage per start, the same electrode damage that darkens the arc tube walls and limits light output. To quantify this unique system benefit, Hubbell has developed an Electro-Reg Equipment Operating Factor (EOF-er). This factor is used during lighting calculations to quantify how much better Electro-Reg Second, weve coupled this with our unique ignitor which helps reduce damage to the electrode. The result a documented longer life for standard lamps. In fact, we will double the published life of the standard lamp when used with the Electro-Reg ballast system (when we provide the lamp with the fixture). performs over the life of the lamp than any other system, including Pulse Start. The EOF-er is 1.11. To use this factor, simply apply it to the initial lumens, as you would ballast factor, luminaire dirt deprecation or any other factor.

Electro-Regs Lumen Maintenance


100 Electro-Reg EOF-er Electro-Reg equipment operating factor = 1.11 Standard CWA 90 80 70 60 50 40

Lamp life
LAMP 175W PS 250W PS 350W PS 400W MH 400W PS PUBLISHED 15,000 15,000 20,000 20,000 20,000 ELECTRO-REG 30,000 30,000 40,000 40,000 40,000

THE INDUSTRY DEFINITION OF LAMP LIFE IS THE NUMBER OF OPERATING HOURS WHEN HALF THE LAMP POPULATION IS EXPECTED TO HAVE FAILED. THE AVERAGE MAINTAINED LUMENS IS THE EXPECTED LEVEL AT 40% OF RATED LIFE.

30 5 10
Hours (thousands)

15

20

81

ELECTRO-REG
Lamp Wattage Regulation

BALLAST SYSTEM ADVANTAGE


WHY ELECTRO-REG IS MORE EFFICIENT. A standard lamp operated on the Electro-Reg ballast system will produce more light for more hours on the job than any other system available. To translate this into energy savings, apply the EOF-er factor when doing lighting calculations. You will find that it takes fewer fixtures to achieve the target lighting level with the Electro-Reg system than with competing alternatives. Since the ballast uses about the same total wattage as the comparable CWA or Pulse Start CWA, fewer fixtures result in less energy used for the job. The fixture comparison charts on the following page illustrate the effect this reduction in fixtures can have. At todays energy prices the result is significant. Who knows what energy prices will be tomorrow?
CWA WATTAGE RANGE WITH 10 LINE VOLTAGE VARIATION PULSE START CWA WATTAGE RANGE WITH 10 LINE VOLTAGE VARIATION ELECTRO-REG WATTAGE RANGE WITH 10 LINE VOLTAGE VARIATION

Electro-Regs Line Dip Tolerance is 30% greater than CWA systems


60% 40% 20% Pulse Start CWA lamp ages 59% 38% Electro-Reg field measurements Standard CWA

LINE DIP TOLERANCE Theres a sudden dip in line voltage and your machine shop instantly goes dark. Now what wait 10 minutes for your HID lamps to restrike? Wouldnt it make more sense and be safer if your HID fixtures were resistant to lamp dropout to begin with? A sudden dip in line voltage may extinguish the lamp arc, requiring most HID fixtures to cool down (from 2 to 15 minutes), re-strike and then warm up. The Electro-Reg ballast tolerates up to a 59% drop in line voltage without losing the arc. CWA and CWA Pulse Start both are about 38% of line voltage. This means that the chance of having HID lamp dropout is much less with an Electro-Reg ballast system. Any facility with unstable power or large electric motors has the potential to experience lamp dropout. Help prevent this potentially dangerous situation, with Hubbells Electro-Reg system.

Electro-Reg maintains 95%+ Line Power Factor over lamp life


100% 90% 80% 70% lamp ages
82

Electro-Reg CWA

ELECTRO-REG AND POWER FACTOR Electro-Reg ballasts are high power factor ballasts. CWA and CWA Pulse Start ballasts are high power factor with a new lamp. As the lamp ages, their power factor goes down. The Electro-Reg ballast, on the other hand, maintains its high power factor rating for the life of the lamp and for the life of the ballast. The benefit is continued good power factor for the facility and the avoidance of utility company demand charges.

ELECTRO-REG
Installation Cost Comparison
Fixture Quantity Fixture Spacing (in feet) Fixture Cost (per fixture) Lamp Cost (per fixture) Conduit Cost (per fixture) Outlet Box Cost (per fixture) Labor Cost (per fixture) Total Installed Cost (per fixture) Total Installed Cost (system)

HOW IT SAVES YOU MONEY


400 Watt Standard Metal Halide M59 Lamp 100 17.0' $148.00 $12.00 $170.00 $100.00 $50.00 $480.00 $48,000.00 400 Watt Pulse Start Metal Halide M135 Lamp 86 17.5' $178.00 $18.00 $175.00 $100.00 $50.00 $521.00 $44,657.14 400 Watt Electro-Reg M135 Lamp 73 19.0' $242.00 $18.00 $190.00 $100.00 $50.00 $600.00 $44,015.44

Assumptions: $10 per linear foot of conduit installed $100 per outlet box installed $50 labor per fixture installed Fixture is 19" open highbay

Energy Cost Comparison


Initial Lumens Lamp Lumen Depreciation Ballast Factor Maintained Lumens Fixtures Required for Equal Lumens System Watts per Fixture Annual Power Costs

400 Watt Standard Metal Halide M59 Lamp 40,000 0.66 0.95 25,080 1.0 458 $320.97

400 Watt Pulse Start Metal Halide M135 Lamp 44,000 0.7 0.95 29,260 0.86 452 $271.51

400 Watt Electro-Reg M135 Lamp 44,000 0.78 1.0 34,188 0.73 450 $231.35

Assumed /kwh at 0.08 Assumed Hrs/Year at 8760

Operating Cost Comparison


Fixture Quantity Rated Lamp Life Lamp Replacements per year Lamp Costs per year Labor Costs per year Energy Costs per year Operating Cost per year

400 Watt Standard Metal Halide M59 Lamp 100 20,000 21.9 $263 $548 $32,097 $32,907

400 Watt Pulse Start Metal Halide M135 Lamp 86 30,000 12.5 $225 $313 $27,241 $27,779

400 Watt Electro-Reg M135 Lamp 73 40,000 8.0 $96 $201 $22,075 $22.372

HUBBELL LAMP WARRANTY


Hubbell Lighting warrants the lamp when supplied with the Electro-Reg fixture by Hubbell, for two years from the date of purchase when operated on the Hubbell Electro-Reg ballast system. Lamps that fail during this period will be replaced free of charge by Hubbell liability issues are the responsibility of the owner. This warranty is valid only if all lamp manufacturers operating and installation instructions are followed and the specific Hubbell Lighting light fixture installation instructions and application recommendations are adhered to. Lamp failures due to physical damage, electrical surges, or other acts of nature are not covered by this warranty.
SAME LAMP. LONGER LIFE.
RATED AT 20,000 HOURS RATED FOR 40,000 HOURS

Lighting. Replacement labor, equipment charges and all resulting

83

INTRODUCING V-SPEC

TRUE 3D VERTICAL SURFACE LIGHTING with the efficiency of an electronic ballast and superior color rendering all from Hubbell Industrial Lighting

V-Spec sets the standard in maximum vertical surface illumination and color rendering. All the qualities you need plus energy savings. Perfect for the retail environment. LOWER OPERATING COSTS 10-point improvement in Lamp Lumen Maintenance allows for lower wattage lamps in retrofits or less fixtures in new construction. A high-efficiency electronic ballast with a high-output PulseArc lamp delivers 70% more mean lumens per watt than probe start metal halide lamps and 20% more mean lumens per watt than pulse start metal halide lamps. APPLICATION VERSATILITY Ballast housing design solves thermal, EMI, UL and mounting concerns. Multi-wattage capability one ballast runs 250, 300, 320, 350 or 400 watt quartz metal halide or ceramic metal halide lamps. Runs on 208-277 volts. Independent 250 watt auxiliary lighting circuit on every unit. IMPROVING QUALITY OF LIGHT Significantly reduces lamp color shift typical with HID lamps. Virtually eliminates flickering. Total Performance System Warranty with GEs ConstantColor CMH lamps.

ELECTRONIC BALLAST DELIVERS UP TO 70% MORE MEAN LUMENS

ONE BALLAST RUNS 5 WATTAGES, SIMPLIFYING INSTALLATION

SUPERWATT 3D LIGHT DISTRIBUTION OPTIC LIGHTS HORIZONTAL AND VERTICAL SURFACES


20 Mounting Height

31.6 30.4 29.5 28.6 27.5 25.7 24.7 21.3 8 20.7 14.3 14.2 10.3 10.5 28.9 24.2 5 30.2 29.1 24.4 30.8 30.6 36.1 10.5 30.6 38.1 14.9 10.3 35.9 22.9 15.2 23.7 24.3 15.4 10.3 38.0 34.7 24.9 15.6 11.4 34.5 26.0 16.7 11.7

Part # UM25-40W-208-277 Part # UM25-40W-208-277-QS Part # CH-SW


With industry-leading engineered optics, V-Spec delivers not only floor (horizontal) footcandles but also critical shelf (vertical) footcandle illumination. More light on your products means improved customer satisfaction and sales.
up to 25% uplight

wide distribution supports superior uniformity in illumination patterns

main beam below glare zone

84

200x200 space w/ 25' mounting height


LAYOUT LAMP & FIXTURE DATA Fixture Mounting Height Initial Lamp Lumens Number of Lamps Initial Fixture Lumens (ballast corrected) Maintained Fixture Lumens Fixture Watts Fixture Lumens/Watt CRI FC Average Maintained Number of Fixtures Cost/kWh Watts/sq foot Annual Operating Hours Annual Energy Costs Total Fixture Cost Labor per Fixture ($100 per fixture) Installation Costs Lamp Costs Lamp Change Labor Scissor Lift Re-Lamping Costs

FLUORESCENT HIGHBAY Fluorescent highbay w/ 6-lamp high-lumen T5 lamps IB 654 WD


25 Foot 4400 6 26400 19737.9 368 53.64 82 72.6 169 $0.10 1.55 6000 $37,315.00 $19,435.00 $16,900.00 $36,335.00 $6,084.00 $1,690.00 $1,500.00 $9,274.00

HUBBELL V-SPEC 400W Electronic highbay w/ Superwatt optics UM2540W208277


25 Foot 40000 1 40000 20908.8 430 48.63 92 69.2 144 $0.10 1.55 6000 $37,152.00 $41,169.60 $14,400.00 $55,569.60 $5,760.00 $1,152.00 $1,500.00 $8,412.00

The comparisons to the left show the Hubbell V-Spec when compared to the popular linear fluorescent highbay fixtures.

FOOTCANDLES OPERATING DATA

Advantages to an HID system include:


EASE OF MAINTENANCE Typical fluorescent systems will have twice the number of fixtures and 10 to 15 times more lamps, resulting in much higher on-going maintenance costs. Contrast a typical warehouse with 250 HID fixtures or 440 fluorescent highbays. Each fluorescent has six lamps while the HID only have one. That means 250 HID lamps to maintain vs. 2640! WIDE TEMPERATURE RANGE Metal halide lamps operate reliably in unconditioned spaces where temperatures can exceed 149F or fall below -40F. Light output from fluorescent lamps will drop off in extreme temperatures. FREEZER APPLICATIONS Metal halide lamp/ballast can be reliable used down to 40C for Electro-Reg and HPS and down to 20C for standard metal halide. AMBIENT TEMPERATURE SUITABILITY HID fixtures are UL tested for ambient temperature ranges of as high as 65C, while fluorescent highbay fixtures are normally tested for only 25C ambient temperature. LOWER INSTALLED COST Metal halide highbay systems are almost always less expensive to install. A typical HID system will have half the number of fixtures as a equivalent fluorescent systems. LARGER LUMEN PACKAGES Mounting heights of more than 20 to 25 feet may lend themselves better to metal halide. SEVERE ENVIRONMENTS A variety of HID highbays are designed expressly for applications that are corrosive, dirty, are wet locations, are subject to vibration or violent impact, or required hazardous location ratings. Fluorescent highbay fixtures are normally rated for damp locations only.

SAVING ANALYSIS

RE-LAMPING COSTS

200x200 space w/ 25' mounting height


LAYOUT LAMP & FIXTURE DATA Fixture Mounting Height Initial Lamp Lumens Number of Lamps Initial Fixture Lumens (ballast corrected) Maintained Fixture Lumens Fixture Watts FOOTCANDLES OPERATING DATA Fixture Lumens/Watt CRI FC Average Maintained Number of Fixtures Cost/kWh Watts/sq foot Annual Operating Hours SAVING ANALYSIS Annual Energy Costs Total Fixture Cost Labor per Fixture ($100 per fixture) Installation Costs Lamp Costs Lamp Change Labor Scissor Lift Re-Lamping Costs

FLUORESCENT HIGHBAY Fluorescent highbay w/ 6-lamp high-lumen T8 lamps IB 632 WD


25 Foot 2950 6 20886 14573.2 168 86.75 82 67.4 272 $0.10 1.14 6000 $27,418.00 $25,840.00 $27,200.00 $53,040.00 $3,264.00 $2,720.00 $1,500.00 $7,484.00

HUBBELL V-SPEC 400W Electronic highbay w/ Superwatt optics UM2540W208277


25 Foot 40000 1 40000 20908.8 430 48.63 92 69 144 $0.10 1.55 6000 $37,152.00 $41,169.60 $14,400.00 $55,569.60 $5,760.00 $1,152.00 $1,500.00 $8,412.00

RE-LAMPING COSTS

200x200 space w/ 25' mounting height


LAYOUT LAMP & FIXTURE DATA Fixture Mounting Height Initial Lamp Lumens Number of Lamps Initial Fixture Lumens (ballast corrected) Maintained Fixture Lumens Fixture Watts Fixture Lumens/Watt CRI FC Average Maintained Number of Fixtures Cost/kWh Watts/sq foot Annual Operating Hours Annual Energy Costs Total Fixture Cost Labor per Fixture ($100 per fixture) Installation Costs Lamp Costs Lamp Change Labor Scissor Lift Re-Lamping Costs

STANDARD MH HIGHBAY 400W Superwatt w/ standard lamp SWD400H8APWH


25 Foot 36000 1 36000 20164.3 460 43.84 62 72.1 169 $0.10 1.94 6000 $46,644.00 $44,987.80 $16,900.00 $61,887.80 $2,535.00 $1,690.00 $1,500.00 $5,725.00

HUBBELL V-SPEC 400W Electronic highbay w/ Superwatt optics UM2540W208277


25 Foot 40000 1 40000 20908.8 430 48.63 92 69 144 $0.10 1.55 6000 $37,152.00 $41,169.60 $14,400.00 $55,569.60 $5,760.00 $1,152.00 $1,500.00 $8,412.00

FOOTCANDLES OPERATING DATA

SAVING ANALYSIS

RE-LAMPING COSTS

85

JUST WHAT IS THE DIFFERENCE BETWEEN HID vs. FLUORESCENT LIGHTING?


There are certain advantages and disadvantages when you need to decide between HID or fluorescent lighting. The right choice has a lot to do with height from the work surface, desired light distribution, type of light, maintenance cost expectations, dirty/dusty ambient environments, and hot or cold ambient environments.

If your application is one that meets one or more of these performance criteria, then HID is the first option to explore.

HID LIGHTING ADVANTAGES


WIDER TEMPERATURE OPERATING RANGES Metal halide lamps operate reliably in unconditioned spaces where temperatures can exceed 149F or fall below -40F. Light output from fluorescent lamps will drop off in extreme temperatures. FREEZER APPLICATIONS Metal halide lamp/ballast can be reliably used down to -40C for Electro-Reg and HPS and down to -20C for standard metal halide. BROAD AMBIENT TEMPERATURE SUITABILITY HID fixtures are UL tested for ambient temperatures as high as 65C, while fluorescent highbay fixtures are normally tested for only 25C ambient temperature. LOWER INSTALLED COST Metal halide highbay systems are typically less expensive to install. A typical HID system will have half the number of fixtures as an equivalent fluorescent systems. LOWER MAINTENANCE Typical fluorescent systems will have twice the number of fixtures and 10 to 15 times more lamps, resulting in much higher on-going maintenance costs. Contrast a typical warehouse with 250 HID fixtures or 440 fluorescent highbays. Each fluorescent has six lamps while the HID only has one. That means 250 HID lamps to maintain vs. 2640! LARGER LUMEN PACKAGES Mounting heights of more than 20 to 25 feet. SEVERE ENVIRONMENTS A variety of HID highbays are designed expressly for applications that are corrosive, dirty, wet locations, subject to vibration or violent impact, or require hazardous location ratings. Fluorescent highbay fixtures are normally rated for damp locations only.

FLUORESCENT LIGHTING WORKS WITHIN SOME LIMITED ENVIRONMENTS INSTANT RESTRIKE In the event of a power interruption, fluorescent lamps are back on instantly. CONTROL FRIENDLY The instant-on capability of fluorescent lamps makes them good for use with occupancy sensors and photocells. LUMEN MAINTENANCE T5 and T8 fluorescent lamps lose 5-6% of their lumen output between their rated initial and maintained lumens (maintained lumens are calculated at 40% of rated life).

86

Top fixture applications


dirty/tough environments: HID required

cold/hot ambient temperatures: HID required

wet/damp locations: HID required

high mounting heights: HID required

retail/consumer locations: HID or Fluorescent

87

PULSESMART
QUASI-RESONANT LIGHTING SYSTEM (277V ONLY)
THE EFFICIENT WAY TO SAVE IN ENERGY, INSTALLATION AND OPERATING COSTS. Hubbell Lighting does it again. Although a standard ballast metal halide fixture is good and a pulse start system is more efficient, our new 750 watt PulseSMART Quasi-Resonant system uniquely combines the best lamp, ballast and fixture technology available.
29" LOWBAY LM 22" ACRYLIC WA22

WHAT DOES THIS ALL MEAN? It means if you are about to specify a 400 watt or 1000 watt system, you need to look at what the PulseSMART Quasi-Resonant system delivers. Compared to a 400 watt or even a 750 watt pulse start metal halide ballast product, we win hands down. When you add total savings in energy, installation and operating costs, you can save as much as 50% over a standard CWA ballasted system (see opposite page for details).
25" ACRYLIC WA25

Covered by patent #5,825,139.

19" ALUMINUM W/ UPLIGHT SU

19" ALUMINUM DOWN LIGHT ONLY SD

22" ALUMINUM OU-60 & FLUSH MOUNT

88

Take a look at how we do it.


Youll see that when you put it all together, we not only deliver better performance but will add more to your bottom line.

Energy Cost Comparison


Initial lumens Published lamp lumen depreciation Ballast factor Mean lumens Fixtures required for equal # of lumens Systems watts per fixture Mean lumens per system watt Watts per square foot Annual power costs 400 watt Standard MH CWA 36,000 0.62 0.95 21,204 1.00 458 46 0.67 $320.97 400 watt Pulse Start MH CWA 44,000 0.76 0.95 31,768 0.65 452 70 0.43 $207.33 1000 watt 750 watt 750 WATT MH Standard MH Pulse Start MH PulseSMART CWA CWA QUASI-RESONANT 110,000 80,000 80,000 0.65 0.95 67,925 0.46 1080 63 0.48 $346.90 0.75 0.95 57,000 0.35 818 70 0.42 $200.64 0.75 1.00 60,000 0.33 787 76 0.38 $180.50
750 WATT 400 WATT 400 WATT 1000 WATT 750 WATT MH STANDARD PULSE START STANDARD PULSE START MH PULSESMART MH MH MH CWA QUASI-RESIDENT CWA CWA CWA
350 300 250 200 150 100

ANNUAL POWER COSTS

Assumed /kwh at $0.08 Assumed Hrs/Year at 8760

Installation Cost Comparison


Fixture quantity Fixture spacing (in feet) Fixture cost (per fixture) Lamp cost (per fixture) Conduit cost (per fixture) Outlet box cost (per fixture) Labor cost (per fixture) Total installed cost (per fixture) Total installed costs (system)
Assumptions:

400 watt Standard MH CWA 220 25 $130.00 $15.00 $250.00 $100.00 $50.00 $545.00 $119,899.56

400 watt Pulse Start MH CWA 144 32 $150.00 $25.00 $320.00 $100.00 $50.00 $645.00 $92,879.71

1000 watt 750 watt 750 WATT MH Standard MH Pulse Start MH PulseSMART CWA CWA QUASI-RESONANT 66 77 72 46 43 43 $225.00 $195.00 $185.00 $30.00 $30.00 $30.00 $460.00 $430.00 $430.00 $100.00 $100.00 $100.00 $50.00 $50.00 $50.00 $865.00 $805.00 $795.00 $57,089.87 $61,984.85 $57,239.86

130,000 120,000 110,000 100,000 90,000 80,000 70,000 60,000 50,000 40,000

TOTAL INSTALLED COST (SYSTEM)

Baseline installation consists of one hundred 400 watt MH fixtures on 25' spacing Cost/linear ft. of conduit installed $10 Cost per outlet box installed $100 Labor cost per fixture installed $50 Fixture is 19" open highbay for 400 and 750 watt units; 1000 watt unit is 23" open highbay

Operating Cost Comparison


Fixture quantity Rated lamp life Lamp replacements per year Lamp costs per year Labor costs per year Energy costs per year Operating costs per year
Assumptions: Energy cost per kwh () Hours per year Labor cost/lamp replaced Lamp cost

400 watt Standard MH CWA 220 20,000 21.9 $329.00 $548.00 $70,613.00 $71,489.00
0.08 8760 $25 $15

400 watt Pulse Start MH CWA 144 20,000 21.9 $876.00 $548.00 $45,614.00 $47,037.00

1000 watt 750 watt 750 WATT MH Standard MH Pulse Start MH PulseSMART CWA CWA QUASI-RESONANT 66 77 72 12,000 24,000 24,000 35.0 7.8 7.8 $1,050.00 $234.00 $234.00 $875.00 $195.00 $195.00 $49,953.00 $44,141.00 $39,710.00 $51,878.00 $44,570.00 $40,139.00

75,000 70,000 66,000 60,000 55,000 50,000 45,000 40,000 35,000

OPERATING COSTS PER YEAR


$40 $30 $30 $30

Total Cost Comparison


Total costs 400 watt Standard MH CWA $191,388.56 400 watt Pulse Start MH CWA $139,916.71 1000 watt Standard MH CWA $108,967.87 750 watt Pulse Start MH CWA $106,544.85 750 WATT MH PulseSMART QUASI-RESONANT $97,378.86
200,000 150,000 100,000 50,000 0

89

HORIZONTAL/VERTICAL/3D LIGHTING
SUPERWATT, LIGHTWATT, TRIBAY SUPERWATT
WHEN YOU NOT ONLY NEED TO LIGHT THE FLOOR BUT YOUR MACHINES AND WAREHOUSE SHELVES, VERTICAL LIGHTING IS THE ANSWER. When measuring how much light your workplace needs, the industry standard only measures a horizontal plane the amount of light delivered at 30" from the floor. Thats fine if there are no obstructions and your employees are doing nothing more than moving materials around on that surface. Realistically, we know that people are required to fix machinery, change parts, check work, see inside warehouse racks, peer into shelves and work productively in all types of visually complex environments. an area and eliminates the cave effect common with inadequately Because of this real world need, weve engineered what we feel are the best solutions for effectively lighting the VERTICAL surfaces of a work area. Additionally, because of a unique optical design, we can deliver superior uniformity of light, knocking out dark areas on the work floor as well as creating an effective overlapping of fixtures. This crossing of light sources translates into backup lighting, so when a lamp does go out the overall darkening effect is lessened on that part of the work floor. As the light leaves the precisely placed lamp, it strikes a prismed lens. The light then moves up (up to 25%) and down to light the vertical and horizontal surfaces. As important, Hubbells 3D system minimizes the light at 60-65 degrees. This projects more light to critical vertical surfaces, yet blocks excessive light in the glare zone. HOW HUBBELLS 3D LIGHTING WORKS The essence in effectively delivering this vertical light is the precise design of each optic. Over decades Hubbell has improved the ability of these tough acrylic lenses to precisely bend each ray and place it so that a specific amount of energy is sent to light the floor, the walls, inside machinery and as uplight to illuminate and reflect off ceilings. This all adds to the general illumination of Add up all this optical engineering expertise and it simply makes it easier for employees to read controls and dials and see inside machinery, minimizing shadowing, making people safer, more productive with less fatigue. And it helps reduce the need for supplemental lighting, reducing energy needs and additional maintenance and installation costs. designed lighting. It also helps reduce shadowing, typical of standard horizontal plane only lighting.
main beam below glare zone wide distribution supports superior uniformity in illumination patterns up to 25% uplight

SUPERWATT

LIGHTWATT

TRIBAY SUPERWATT

90

Features & requirements

dimming/wiring systems

single wire zone control

Each Switch Level Dimming luminaire requires either a 4-wire plug and receptacle or a 4-wire splice connection. Each SLIP interface panel starts all luminaires at high light levels and prohibits luminaire dimming for a preset 15 minute period to allow complete warm-up according to all lamp manufacturers requirements. One control wire is required for each control zone. The SLIP interface panel must be powered by 120V AC and be connected to the service common. An autotransformer can be used to supply the SLIP interface voltage if the system voltage is other than 120V AC, typically supplied by installing contractor. Each SLIP interface panel is supplied with manual override terminals, that when connected by a switch will force all luminaires (in all zones) to full output. Each SLOD occupancy detector is energized by an independent 120V AC source for maximum versatility. One or more SLOD occupancy detectors are required for each zone, if independent multiple zone control is desired. Zones may contain luminaires wired to multiple phases. Multiple SLOD occupancy detectors, wired in parallel, may be used to control one zone. Each SLOD occupancy detector must be wired to the SLIP interface panel.

slip 3

ordering information
Catalog Number slod1 slod2 slip3 Description PIR, 120V, High Mount, Aisle Detector PIR, 120V, Open Area Detector Interface Panel, single wire control (120V AC)

industrial

SLIP Specifications supply Connection supply Voltage (Volts aC) supply Current (amps aC) Maximum Current per Zone (amps aC) Maximum number of slls per Zone (150W-400W) Maximum number of slls per Zone (600W-1500W) Maximum number of slls per slip (150W-400W) Maximum number of slls per slip (600W-1500W)

SLIP-3 120 3.0 (max) .32 10 4 80 32

slod2

slod3

A GRD N C B OPTIONAL STEP DOWN TRANSFORMER

SLIP 3

SLOD DETECTORS

OPTIONAL OVERRIDE SWITCH

IMPORTANT: All Hubbell Lighting, Inc. SLD Control Systems provide a 15 minute START AT HIgH circuit to bring the HID lamps up to full power prior to any dimmed operation. This is required for full lamp warranty and proper system operation. Operation without START AT HIgH will void the HLI SLD equipment warranty and lamp warranty.

91

dimming/wiring systems
two-wire zone control

Features & requirements

slip 2

Each Switch Level Dimming luminaire requires either a 5-wire plug and receptacle or a 5-wire splice connection. Each SLIP interface panel starts all luminaires at high light levels and prohibits luminaire dimming for a preset 15 minute period to allow complete warm-up according to all lamp manufacturers requirements. Two control wires are required for each control zone. The SLIP interface panel must be powered by 120V AC and be connected to the service common. An autotransformer can be used to supply the SLIP interface voltage if the system voltage is other than 120V AC, typically supplied by installing contractor. Each SLIP interface panel is supplied with manual override terminals, that when connected by a switch will force all luminaires (in all zones) to full output. Each SLOD occupancy detector is energized by an independent 120V AC source for maximum versatility. One or more SLOD occupancy detectors are required for each zone, if independent multiple zone control is desired. Zones may contain luminaires wired to multiple phases. Multiple SLOD occupancy detectors, wired in parallel, may be used to control one zone. Each SLOD occupancy detector must be wired to the SLIP interface panel.

ordering information

industrial

Catalog Number slod1 slod2 slip2

Description PIR, 120V, High Mount, Aisle Detector PIR, 120V, Open Area Detector Interface Panel, double wire control (24V AC)

SLIP Specifications supply Connection SLIP-2 supply Voltage (Volts aC) 120 supply Current (amps aC) 3.0 (max) Maximum Current per Zone (amps aC) .32 Maximum number of slls per Zone (150W-400W) 10 Maximum number of slls per Zone (600W-1500W) 3 Maximum number of slls per slip (150W-400W) 80 Maximum number of slls per slip (600W-1500W) 24

slod 2

slod 3

A DIST. PANEL (by others) N G B C OPTIONAL STEP DOWN TRANSFORMER

SLIP 2

SLD2

SLD2

SLD2

SLOD DETECTORS

OPTIONAL OVERRIDE SWITCH

92

IMPORTANT: All Hubbell Lighting, Inc. SLD Control Systems provide a 15 minute START AT HIgH circuit to bring the HID lamps up to full power prior to any dimmed operation. This is required for full lamp warranty and proper system operation. Operation without START AT HIgH will void the HLI SLD equipment warranty and lamp warranty.

Features & requirements

dimming/wiring systems

Each Switch Level Dimming luminaire requires either a 4-wire plug and receptacle or a 4-wire splice connection Each SLOD3 occupancy detector is energized by an independent 120/277V AC source for maximum versatility. great for warehouse aisles. Eliminates the need for a SLIP control panel. Simple, more efficient installation.

ordering information
Catalog Number slod3 -sld1 -sld3 Description For Direct Control (with SLD1 or SLD3) Fixture Option 120V control Fixture Option 277V control

industrial

slod 3

superbay -sld1/-sld3

tribay -sld1/-sld3

GROUND DISTRIBUTION PANEL (by others) 277V COM CONTROL 277V COM CONTROL

BLACK

SLOD-3

SLOD-3

SLD1/SLD3

SLD1/SLD3

SLD1/SLD3

TYPICAL AISLE WIRING DIRECT CONTROL

IMPORTANT: All Hubbell Lighting, Inc. SLD Control Systems provide a 15 minute START AT HIgH circuit to bring the HID lamps up to full power prior to any dimmed operation. This is required for full lamp warranty and proper system operation. Operation without START AT HIgH will void the HLI SLD equipment warranty and lamp warranty.

BLACK

WHITE

WHITE

RED

RED

93

dimming/wiring systems
manual zone control

Features & requirements

Single zone applications. 120V control (SLD1). Operates up to 40 fixtures 400 watts or less. Operates up to 10 fixtures over 400 watts. Includes electronic start at high module (required for lamp warranty). Ready to install including backbox electronics and decorative face plate with on/off and hi/low switches. Perfect for single zones requiring manual control only. Switches illuminate when in the on and high positions for easy identification and confirmation. Saves on equipment and installation costs when simplicity of control is desirable. For use with fixtures powered by 120 or 277V AC.

ordering information

industrial

Catalog Number sliC -sld1 -sld3

Description Manual Zone control Fixture Option 120V control Fixture Option 277V control

PANEL DISTRIBUTION (120V) PANEL DISTRIBUTION (NEUTRAL) CONTROL LEAD (120V AC)

SLIC DISTRIBUTION PANEL (by others) SLD FIXTURE TO LIGHTING CONTACTOR (120V AC COIL) SLD FIXTURE SLD FIXTURE

120 TO 277V FIXTURES ONLY LIGHTING CONTACTOR (by others)

94

IMPORTANT: All Hubbell Lighting, Inc. SLD Control Systems provide a 15 minute START AT HIgH circuit to bring the HID lamps up to full power prior to any dimmed operation. This is required for full lamp warranty and proper system operation. Operation without START AT HIgH will void the HLI SLD equipment warranty and lamp warranty.

dimming/wiring systems
Ch-sld tribay With sWitCh leVel diMMing
ONLy 8 SELECTIONS MUST BE MADE TO SPECIFy A COMPLETE PRODUCT.

switch level dimming

CH - 40 - H - 4 - M - CXP - WA22 - SLD1 - TLR


#4 selection #2 #3 #5 #6 #7 1 Control Voltage select the control voltage from applicable systems on preceding pages. 2 Fixture Wattage 250, 400, 600 or 1000 watt. 3 Lamp Type Metal halide, high pressure sodium or Pulse Start. 4 Primary Voltage A specific voltage must be selected. Quad-Taps and Tri-taps are not an option. We may use Quad-Tap and Tri-tap ballasts to 5 6 7 8 #1 #8 service the orders but 6 and 8 can not be selected. Not all voltages will be available with each previously chosen Control Voltage selections. Mounting Box Selection Wiring Method cord and plug or no cord. Optical Selection Option Selection Anodized housing, EM, Fusing, QST, Remote, LRI, TRI

ordering information
series Ch Tribay Wattage 25 250 watt 40 400 watt 60 600 watt 10 1000 watt ballast/lamp h Metal Halide standard PLA s HPS standard CWA, AL W Pulse Start Fixture Voltage SLD1 VOLTAgE 1 120 volt 4 277 volt F 347 volt SLD2 VOLTAgE 1 120 volt 2 208 volt 3 240 volt 4 277 volt 5 480 volt F 347 volt

Example: CH - 40 - H - 4 - CXP - OU - SLD1 - EM


optics dimming Wattage ballast/ Fixture options Wiring lamp Voltage Method Control Fixture Voltage cont dimming Control SLD3 VOLTAgE sld1 120V control sld2 24V control 4 277 volt sld3 277V control Wiring Method options Cxp 4 Conductor Cord & Plugs an Anodized Housing/Reflector connected in side of Slick-On box, eM Emergency Quartz Socket X = cord length, replace with Fx Fusing (X = line voltage) 2, 4, 6, 10 qst Quartz Standby w/ time delay dpt 4 Conductors available for ro Remote Ballast connection in Slick-On box lri Lower Retainer Installed optics trix Top Retainer Installed, X = length, eu Enclosed Highbay replace with 6, 10, 12, or 16 ou Open Highbay CFb Charcoal Filter Breather lM 29 Lowbay Reflector/Refractor pC Polycarbonate Reflector (Controlux) sW Superwatt Plus Wa22 22" Prismatic Acrylic Wd22 22" Diffused Prismatic Acrylic Wa25 25" Prismatic Acrylic na No Optics, enclosed highbay nb No Optics, open highbay nC No Optics, SW nd No Optics, prismatics ne No Optics, LM series

industrial

bl-sld superbay With sWitCh leVel diMMing ONLy 7 SELECTIONS MUST BE MADE TO SPECIFy A COMPLETE PRODUCT. BL - 40 - H - 4 - CXP - SU - SLD1 - TLR
selection 1 2 3 4 #2 #3 #4 #5 #6 #1 Control Voltage select the control voltage from applicable systems on preceding pages. Fixture Wattage 150, 175, 250 or 400 watt. 5 Lamp Type Metal halide, high pressure sodium or Pulse Start. Primary Voltage A specific voltage must be selected. Quad-taps and 6 7 Tri-taps are not an option. We may use Quad-tap and Tri-tap

#7 ballasts to service the orders but 6 and 8 can not be selected. Not all voltages will be available with each previously chosen Control Voltage selections. Wiring Method cord and plug or no cord (DPT). Optical Selection Option Selection Remote, Fuse, TLR, LLR, EM

ordering information
series bl Superbay Wattage 15 150 watt 17 175 watt 25 250 watt 40 400 watt ballast/lamp h Metal Halide s HPS W Pulse Start Fixture Voltage SLD1 VOLTAgE 1 120 volt 4 277 volt F 347 volt SLD2 VOLTAgE 1 120 volt 2 208 volt 3 240 volt 4 277 volt 5 480 volt F 347 volt

Example: BL - 40 - H - 4 - CXP - SU - SLD1 - TLR


optics dimming Wattage ballast/ Fixture Wiring options lamp Voltage Method Control Fixture Voltage cont dimming Control SLD3 VOLTAgE sld1 120V control sld2 24V control 4 277 volt sld3 277V control Wiring Method options Cxp 4 Conductor Cord & Plugs CFb Charcoal Filter Breather connected in side of Slick-On box, eM Emergency Quartz Socket X = cord length, replace with 2, 4, 6, 10 F Fusing dpt 4 Conductors available for p High Strength Polycarbonate connection in Slick-On box Reflector ro Remote Ballast optics al 19" Aisle Lighter tlr Top Luminaire Retainer nMM No Mounting Method bi 14" Highbay Reflector eg 19" Enclosed & gasketed lb1 23" Lowbay lM 29" Lowbay pa 16" Prismatic Acrylic sd 19" Highbay Downlight su 19" Highbay Uplight Wa 25" Prismatic Acrylic series

95

dimming/wiring systems
switch level dimming

applications/energy savings
Fixture Option -SLD1 -SLD3 -SLD1 -SLD3 -SLD2 -SLD2 -SLD2 -SLD2 -SLD2 -SLD2 -SLD1 -SLD1 -SLD1

Direct Wire Two Wire Control SLIP 2

120v 277v 24v 24v 24v 24v 24v 24v 120v 120v 120v

F F G G G G G G F F F

G G G G P G G G G P G G G G G G P P P G G G G G G P P P G G G G G G F F F G G G G G G F F F P P P P P P

F F F F F F F F

G G G G G G G G G G G G F F F G G G G G G F F F G G G G G G F F F

120v 277v 120v 208v 240v 277v 347v 480v 120v 277v 347v

Manual Control SLIC

G G G G G G

Percent of Time Fixtures on Low

Single Wire Control SLIP 3

Control Voltage 120v 120v 120v

Ma nu fac Dis tur i ng trib u ti Fa Wa o c reh n Ce ilities nte ou Tra se rs s ns it T Lo ad ermi na in ls Gy g D oc ms ks Ch urc he Lo s bb ie Sh s op p Re ing M tai all lS to r s es

G G G G G P G G G G G P G G G G G P

F F F

G G G G G G G G G

Fixture Voltage 120v 277v 347v

Energy Savings per Fixture per Year


Rate 30.0% 35.0% 40.0% 45.0% 50.0% 55.0% 60.0% 65.0% 70.0% 75.0% 80.0% $0.05 $12.42 $14.49 $16.56 $18.63 $20.70 $22.77 $24.84 $26.91 $28.98 $31.05 $33.12 $0.06 $14.90 $17.39 $19.87 $22.36 $24.84 $27.32 $29.81 $32.29 $34.78 $37.26 $39.74 $0.07 $17.39 $20.29 $23.18 $26.08 $28.98 $31.88 $34.78 $37.67 $40.57 $43.47 $46.37 $0.08 $19.87 $23.18 $26.50 $29.81 $33.12 $36.43 $39.74 $43.06 $46.37 $49.68 $52.99 $0.09 $22.36 $26.08 $29.81 $33.53 $37.26 $40.99 $44.71 $48.44 $52.16 $55.89 $59.62 $0.10 $24.84 $28.98 $33.12 $37.26 $41.40 $45.54 $49.68 $53.82 $57.96 $62.10 $66.24 $0.11 $27.32 $31.88 $36.43 $40.99 $45.54 $50.09 $54.65 $59.20 $63.76 $68.31 $72.86 $0.12 $29.81 $34.78 $39.74 $44.71 $49.68 $54.65 $59.62 $64.58 $69.55 $74.52 $79.49

Assumptions: 12 hours per day 6 days per week 400 watt metal halide

G = GOOD

F = FAIR

P = POOR

slod1
FRONT TOP
TOP VIEW

7 0

industrial

30
SETTINGS FOR FUNCTIONAL TESTING SETTINGS FOR SHIPMENT

20 SIDE 10 0 SIDE VIEW

SWITCH LOCATIONS DETAIL

AISLE DETECTOR

10

20

30

40

50 60 70 FIELD OF VIEW

80

90

100

110

120

slip2

TYP. BLK
BLU WHT RED

RED

WHT WHT SLOD 1 WIRING DIAGRAM

slod2
35

HINGE SIDE

30

AREA DETECTOR

20

45

slip3
BLK WHT RED

BLK

RED 10

WHT TYP. WHT

SLOD 2 WIRING DIAGRAM 20 10 0 FIELD OF VIEW 10 20

HINGE SIDE
OVERRIDE
120V A.C. NEU.

96

120V A.C. NEU.

NEU. 120V A.C.

OVERRIDE

Features

dimming/wiring systems

modular wiring

The Flex3+ flexible wiring system from ACS speeds up the installation of high intensity discharge (HID) industrial lighting fixtures with light sources such as high pressure sodium, metal halide, pulse start metal halide, and Hubbell Lightings exclusive Electro-Reg 2.0 metal halide ballast system. The Flex3+ modular wiring system requires only three basic components to supply power to lighting fixtures in both highbay and lowbay locations. These components can easily be installed or relocated by simply unplugging and reinstalling connections. Hubbell provides its fixtures hardwired with the ACS Flex3+ Fixture Cord Drop, ready to plug into the Flex3+ Distribution Cables and Extender Cables (order directly from ACS). Common Flex3+ applications include highbay and lowbay lighting fixtures in industrial locations such as factories or warehouses and retail locations such as supermarkets and big box stores. All components in the Flex3+ system are rated for use on 20 ampere branch circuits and are UL listed and labeled. The ACS Flex3+ wiring system is compatible with the following Hubbell Lighting industrial fixtures: Tribay Superbay Superwatt Lightwatt Microlux

industrial

tribay

superbay

superWatt

liteWatt

MiCrolux

97

dimming/wiring systems
modular wiring
Distribution Box supplied and installed by E.C. Distribution Cable Extender Cable Extender Cable

Hardwire to panel by E.C.

Lighting Tee w/ Drop Cord

Lighting Tee w/ Drop Cord

SUPPLIED BY HUBBELL ORDER FROM ACS

industrial

Typical Highbay Fixture

Typical Highbay Fixture

installed Cost Comparison


Backup Highbay fixture Industrial space, 2 circuits, 25' centers 35' ceiling, panel switching, 8 fixtures per row p & Wire ipe Materials Material Cost 8.95 8.45 0.66 1.92 1.79 15.15 5.00 $41.92 total Cost $200.92 Labor 1.00 hr. 0.40 hr. 0.10 hr. 0.15 hr. 0.70 hr. 0.30 hr. 0.00 hr. 2.65 hrs. $159.00* Flex 3 by aCs Materials 1 - 2EB25 5 - Caddy supports 1 - C2LA03 1 - 2PHA 1 - Pre-wire C2LA03 by fixture manuf. 1 - Fixture hook pre-wire 5.00 $61.81 0.00 hr. 0.00 hr. 0.50 hrs. $30.00* Material Cost 31.81 1.50 9.60 8.90 5.00 Labor 0.20 hr. 0.20 hr. 0.05 hr. 0.05 hr, 0.00 hr.

25' conduit 3/4 EMT + 2 couplings 100' THHN black stranded 2 - 3/4 steel connectors 2 - caddy supports 1 - Raco 4x21/8 box 1 - 18/3 Hubbell 1 - fixture hook

$91.81

*national $ average @$60.00/hr

98

What is Extreme Lighting?

ExtrEmE Lighting

Hubbells Extreme Lighting provides lighting solutions for demanding conditions. Markets falling in this category are Harsh, Hazardous, Marine, Cleanroom, and Specialty (e.g., warning or obstruction). There is overlap potential with all of these markets. For example, a Harsh Environment such as a sewage treatment plant may also be a Hazardous location. Cleanrooms can be Hazardous, and Marine are also Harsh. Typical installations served by Extreme lighting are power plants, waste water, and sewage treatment plants, food processing, petrochemical and chemical plants, shipboard, grain processing, pharmaceuticals, semi-conductor facilities, offshore platforms, FPSOs, pulp & paper plants, and coastal areas, just to name a few.

When you think enclosed and gasketed luminaires, think Hubbell Lighting Extreme.
Hosedown Specifications
There are many claims in the lighting industry that luminaires can withstand 400, 600, or 1000 PSI. It is important to know parameters to which these tests were conducted, because nozzle size, flow rate/pressure, distance and time play a key part in results. For example, a 1/2 nozzle of 1,000 PSI at 6 inches could cut a solid brick, but the same pressure hose from a mist nozzle may not penetrate a sheet of paper from 6 feet. Hubbell Lighting makes every effort to credibly test our luminaires by being listed with certified testing authorities such as CSA and UL. Typical washdown listings include UL 1598A Marine Outdoor, NEMA 4, Ingress Protection IPx6 and IPx5.
Test Marine Outdoor1 NEMA 4X1 NEMA 41 NEMA 31 IPx62 (NEMA4 Equivalent) IPx52 (Between NEMA 3-4 equivalent)
1 2

Nozzle Dia. 1 1 1 1 12.5 mm (1/2) 6.3 mm (1/4)

Distance 10 10 10 10 10 10

Time 5 min 5 min 5 min 5 min 3 min 3 min

Flow Rate

Supplemental Test Criteria

Spec

15 psi 200 hour salt fog UL 1598 Marine Outdoor (~115 gal/min or ASTM B117-1985 (Salt) 435 liters/min) 65 gal/min 200 hour salt fog UL50 ASTM B117-1985 (246 liters/min) (Salt) 65 gal/min UL50 (246 liters/min) 45 gal/min UL50 (~170 liters/min) 100 liters/min Luminaire operated for 1 hour, then IEC529 (26.4 gal/min) power terminated prior to test2 12.5 liters/min Luminaire operated for 1 hour, then IEC529 (3.3 gal/min) power terminated prior to test2

These tests are designed to be performed on an empty enclosure. Hose test is performed on a static enclosure without any pressure changes in the housing. IP Tests are dynamic, and pressure changes take place during the test. When power is terminated, the luminaire housing creates a negative pressure (vacuum) which attempts to pull in any external water or dust surrounding the luminaire.

SEVERE

Temperature Codes (T-Codes)

The ignition temperature or auto-ignition temperature (AIT) is the minimum temperature required to initiate or cause self-sustained combustion in a substance without any apparent source of ignition. The lowest published ignition temperature should be the one used to determine the acceptability of equipment. This is of particular concern when selecting heat producing equipment such as lighting fixtures or motors which may generate sufficient heat to ignite the surrounding atmosphere. Class I and Class II, areas use T-Codes or are subject to maximum temperature limitations as shown in the following chart. North America and the IEC are consistent in their temperature or T-Codes. However unlike the IEC, North America includes incremental values as shown below.
North American Temp. Codes US (NEC-500) & CSA T1 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6 IEC/CENELEC/US (NEC 505) Temp. Codes T1 T2 T3 T4 T5 T6 Maximum Temperature C F 450 842 300 572 280 536 260 500 230 446 215 419 200 392 180 356 165 329 160 320 135 275 120 248 100 212 85 185

99

Protection Classes of Enclosures (Ingress Protection Code)

ingrEss protEction

The IEC uses the term IP to identify the environmental protection of an enclosure. This is defined in IEC Standard 529 and is referenced by the CEC. NEMA Enclosure Types may be converted to IP code designations. The IP classification system designates, by means of a number, the degree of protection provided by an enclosure and the electrical equipment against physical contact, foreign bodies and water ingress. The protection classes for electrical equipment in respect of: 1. Protection of persons against contact with live or moving parts. (Physical contact protection) 2. Protection against ingress of solid foreign bodies. (Foreign body protection) 3. Protection against ingress of water. (Water protection) IF a code digit does not have to be given it should be replaced with the letter X. The key point to note with IP classification is that the tests are dynamic. Prior to testing, the luminiares are operated with the highest rated lamp combination for one hour. The luminaires are powered down just prior to testing and this creates a vacuum in the luminaire, or causes it to contract. Therefore, the luminaire is making every attempt to pull in whatever dust or water it is being subjected to during the test. These are very viable and realistic tests.

ENVIRoNMENTAL LIgHTINg

The IP code indicates the degree of protection provided by enclosures for electrical equipment. The first numeral indicates protection of persons against access to dangerous parts and protection of internal equipment against the ingress of solid foreign objects.

IP
x 0 1 2 3 4 5 Brief Description Protection unspecified (untested) Non-protected Protected against solid foreign objects of 2 diameter and greater Protected against solid foreign objects of 1/2 diameter and greater Protected against solid foreign objects of 0.10 diameter and greater Protected against solid foreign objects of 0.04 diameter and greater Dust protected

Definition The object probe, sphere 2 diameter shall not fully penetrate1 The object probe, sphere of 1/2 diameter shall not fully penetrate1 The object probe, sphere of 0.10 diameter shall not fully penetrate1 The object probe, sphere of 0.04 diameter shall not fully penetrate1 Ingress of dust is not totally prevented, but dust shall not penetrate in a quantity to interfere with satisfactory operation of the apparatus or to impair safety No ingress of dust

6
1

Dust-tight

The full diameter of the object probe shall not pass through an opening of the enclosure.

The second numeral indicates protection of internal equipment against harmful ingress of water.

IP
X 0 1 2 3 4 5 Brief Description Protection unspecified (untested) Non-protected Protected against vertically falling water drops Protected against vertically falling water drops when enclosure tilted up to 15 on either side of the vertical Protected against spraying water Protected against splashing water Protected against water jets

Definition Vertically falling drops shall have no harmful effects Vertically falling drops shall have no harmful effects when the enclosure is tilted at any angle up to 15 on either side of the vertical Water sprayed at an angle up to 60 on either side of the vertical shall have no harmful effects Water splashed against the enclosure from any direction shall have no harmful effects Water projected in jets against the enclosure from any direction shall have no harmful effects. 12.5 liters/min. for 3 minutes, 6.2 mm (1/4) nozzle diameter @ 10 distance Water projected in powerful jets against the enclosure from any direction shall have no harmful effects. 100 liters/min. for 3 minutes, 12.5 mm (1/2) nozzle diameter @ 10 distance Ingress of water in quantities causing harmful effects shall not be possible when the enclosure is immersed in water for 30 minutes. Waterlevel on enclosure: 6 above top and 39 above bottom

Protected against powerful water jets

Protected against the effects of temporary immersion in water

100

hAZArDoUs nEc
Hazardous (Classified) Locations
Hazardous locations are those locations where fire or explosion hazards may exist due to flammable gases or vapors, flammable liquids, combustible dust, or ignitable fibers or flyings. Although flammable gases and vapors, and combustible dusts exist almost everywhere, they are usually present only in minute quantities, much less than necessary for a fire or explosion hazard to exist. Thus, the presence of a flammable gas or vapor, or combustible dust, does not in itself define a hazardous location. These materials must be present in sufficient quantities (concentrations) to present a potential explosion hazard. Locations where there is an explosion hazard because of the presence of high explosives, such as blasting agents and munitions, are not classified as hazardous locations. There are standards covering the handling and use of such materials, and some of these require electrical equipment suitable for use in hazardous locations. This is because such equipment provides a greater degree of safety than ordinary location or general-purpose equipment, not because such equipment has been tested for use in the presence of high explosives. In a like manner, locations made hazardous because of the presence of pyrophoric materials, such as some phosphorous compounds and finely divided metal powders are not classified as hazardous locations. Pyrophoric is defined in the dictionary as igniting spontaneously or emitting sparks when scratched or struck, especially with steel. Where pyrophoric material or high explosives are present, precautions beyond those in the electrical codes are necessary. of electrical equipment or processes might release ignitable concentrations of flammable gases or vapors, and might also cause simultaneous failure of electrical equipment in such a way as to directly cause the electrical equipment to become a source of ignition. An example of such a location might be an area where a flammable liquid is stored under cryogenic conditions, and a leak of the extremely low temperature liquid directly onto electrical equipment could cause failure of the electrical equipment at the same time the vapors of the evaporating liquid are within the flammable range. Division 2 Class I, Division 2 locations are those where ignitable concentrations of flammable gases or vapors are not normally present, but could be present in the event of a fault, such as a leak at a valve in a pipeline carrying flammable liquids. Division 2 locations also often exist around Division 1 locations where there is no barrier or partition to separate the Division 1 space from a non-hazardous location, or where ventilation failure (an abnormal condition) might extend the area where flammables exist under normal conditions. Electrical equipment approved for Class I, Division 1 locations is also suitable for use in Division 2 locations.

ENVIRoNMENTAL LIgHTINg

CLASS II LoCATIoNS

CLASS I LoCATIoNS

Class I locations are those in which flammable gases or vapors are or may be present in the air in quantities sufficient to produce explosive or ignitable mixtures. The term gases or vapors is used because of common usage in the English language. The term gases is commonly used to refer to materials that are in a gaseous state under normal atmospheric conditions, such as hydrogen and methane. The term vapors refers to the gases over a material that is a liquid under normal atmospheric conditions (such as gasoline) but which emits gases within the flammable range under these same atmospheric conditions.

Class II locations are those that are hazardous because of the presence of combustible dust. Note that the dust must be present in sufficient quantities for a fire or explosion hazard to exist. The fact that there is some combustible dust present does not mean a Class II hazardous location exists. To be considered a dust the combustible material must exist as a finely divided solid of 420 microns (0.420 mm) or less. Such a dust will pass through a No. 40 U.S. sieve.

CLASS II, DIVISIoNS 1 AND 2 gRoUPS E, F, AND g LoCATIoNS

CLASS I, DIVISIoNS 1 AND 2 gRoUPS A, B, C, AND D LoCATIoNS

General Just as in Class I, Divisions 1 and 2, the subdivision of Class II into Divisions 1 and 2 identifies the likelihood that there will be an explosion hazard. Division 1 A Class II, Division 1 location is one where combustible dust is normally in suspension in the air in sufficient quantities to produce ignitable mixtures, or where mechanical failure or abnormal operation of equipment or machinery might cause an explosive or ignitable dustair mixture to be produced, and might also provide a source of ignition through simultaneous failure of electrical equipment. A Class II, Division 1 location also exists where combustible dusts of an electrically conductive nature may be present in hazardous quantities (Group E locations). The term hazardous quantity is intended to mean those locations where the dust may not be in suspension in the air in sufficient quantity to cause an explosion, but might have settled on electrical equipment so that the electrically conductive particles can penetrate the openings in the electrical equipment enclosure and cause an electrical failure, or where the dust can get into motor bearings and cause excessive temperatures because of bearing failure.

General The subdivision of Class I into two divisions identifies the likelihood or risk that an ignitable concentration of gases or vapors will be in the location. Division 1 identifies locations where the risk is high or medium. Division 2 identifies locations where there is a small but still finite risk. If the risk is extremely low, the location is not considered a hazardous location. A single family home typifies such a location with natural gas or propane as the energy source for heating. The gas could, and on extremely rare occasions does leak into the home, and an explosion could occur. However the risk is so low (because of the safety systems built into the gas supply and heating equipment) that such locations are not classified as hazardous. Division 1 Class I, Division 1 locations are those where the explosion hazard exists under normal operating conditions. The area may be hazardous all or most of the time, or it may only be hazardous some of the time. Division 1 also includes locations where breakdown or faulty operation

101

hAZArDoUs nEc
Hazardous (Classified) Locations
Division 2 A Class ll, Division 2 location is one where combustible dust is not normally in the air in quantities sufficient to produce explosive or ignitable mixtures, and dust accumulations are not normally sufficient to interfere with the normal operation of electrical equipment, such as clogging ventilating openings or causing bearing failure. It includes locations where combustible dust may be in suspension in the air only as a result of infrequent malfunctioning of handling or processing equipment, and those locations where dust accumulation may be on or in the vicinity of the electrical equipment and may be sufficient to interfere with the safe dissipation of heat from the equipment, or may be ignitable by abnormal operation or failure of the electrical equipment. Class II, Groups E, F, and G The division into three groups in Class II locations is for the same reasons Class I locations are divided into Groups A, B, C, and D: equipment design and area classification. However, the three Class II groups are based on different characteristics than the four Class I groups because the design of dust-ignition proof equipment for Class II locations is based on different principles than the design of explosion proof equipment for Class I locations. In Class II locations the ignition temperature of the dust, the electrical conductivity of the dust, and the thermal blanketing effect the dust can have on heat-producing equipment, such as lighting fixtures and motors are the deciding factors in determining the Class II group. Group E Group E dusts include the metal dusts, such as aluminum and magnesium. In addition to being highly abrasive, and thus likely to cause overheating of motor bearings if the dust gets into the bearing, Group E dusts are electrically conductive. If they are allowed to enter an enclosure, they can cause electrical failure of the equipment. Group F The Group F dusts are carbonaceous, the primary dust in this group being coal dust. These dusts have somewhat lower ignition temperatures than the Group E dusts and a layer of a Group F dust has a higher thermal insulating value than a layer of a Group E dust, thus requiring more careful control of the temperature on the surface of the equipment. Such dusts are semi-conductive but this is not usually a factor for equipment rated 600 volts and less.
Division 1 Risk

Group G The Group G dusts include plastic dusts, most chemical dusts, and food and grain dusts. They are not electrically conductive. These dusts, in general, have the highest thermal insulating characteristics and the lowest ignition temperatures. Thus, dust ignition proof equipment for use in Group G atmospheres must have the lowest surface temperatures to prevent ignition of a dust layer by the heat generated within the equipment. Because of the different design characteristics, equipment suitable for Class I locations is not necessarily suitable for Class II locations, and equipment suitable for Class II locations is not necessarily suitable for Class I locations. The equipment must be approved for each class and group of location involved. Much equipment suitable for Class I locations is also suitable for Class II locations, and is so marked, although when used in Class II locations there may be restrictions, such as lower maximum lamp wattage to maintain the lower surface temperature needed for equipment in dust atmospheres. In Class II areas all products must operate at temperatures based on whether they are heat producing or subject to overloading or not, and based on the Group which they fall under. Class III products in all cases must operate below 165 C.

SEVERE

CLASS III LoCATIoNS

Class III locations are those that are hazardous because of the presence of easily ignitable fibers or flyings, but in which the fibers or flyings are not likely to be in suspension in the air in quantities sufficient to produce ignitable mixtures. Easily ignitable fibers and flyings present a fire but not an explosion hazard. A typical example of this type of material is the cotton lint that accumulates in the lint trap of clothes dryers. Listed clothes dryers are designed so that even if the lint ignites, the fire will be contained within the dryer enclosure.

CLASS III, DIVISIoNS 1 AND 2

Division 1 This is a location where the equipment producing the ignitable fibers or flyings is located (near textile mill machinery, for example) or where the material is handled (for example, where the material is stuffed into bags). Division 2 This is a location where the easily ignitable fibers are stored or handled, except in manufacturing processes (which is Division 1). Class III Groups There are no groups in Class III locations.

Division 2 Not Classified 1 Hour per Year 10 Hours per Year Duration of time gas is present

102

Features
For use in classified areas such as paint manufacturing, munitions facilities, chemical and petrochemical, oil & gas production, and marine loading terminals. Compact size for medium base incandescent and HID lamps, plus twin FL (lamp provided). Mounting choices of pendant, ceiling, 25 stanchion or 90 wall mount with wireless design for quick installation. Factory sealed no external seal required. Available with guard, standard dome or 25 reflector, or exit sign. Housing, Mounting Adaptor, Guard Copper-free (<0.4%) aluminum with powder polyester finish, electrostatically applied. Hardware 316 stainless steel. Reflectors Fiberglass reinforced polyester. UL844 Standard: Class I, Div. 1, Groups C, D; Class II, Div. 1 & 2, Groups E, F, G; Class III, Div. 1 & 2. UL1598A Marine Outdoor. NEMA 3, 4, 4X, 7 (C, D), 9 (E, F, G). UL1598 Wet Location.

hLE sEriEs

ordering Information

Example: HLE
Series

M
Lamp Base

H
Lamp Type

07
Watts

Q
Volts

A2
Mount

G
guard

Series HLE Series HLE Lamp Base Medium Base M Bi-pin Base B Lamp Type Incandescent I Fluorescent F HPS S MH H M MV

150W, A-21, INC 300W, PS-25, INC 300W, PS-30, INC (1) 13W, Bi-Pin FLUOR (2) 13W Bi-Pin or (1) Quad-Pin 26W FLUOR 35 35W, HPS 05 50W, HPS, MH, MV 07 70W, HPS, MH 75 75W, MV 10 100W, HPS, MH, MV 15 150W, HPS Voltage (@ 60 Hertz) Quadri-Volt (120, 208, 240, 277V) 0 120V 1 277V 4 5 480V 6 347V Canada (70, 100 MH/HPS)

Wattage 15 20 30 13 26

Mounting Type 3/4 Pendant A2 1 Pendant A3 3/4 Ceiling X2 1 Ceiling X3 3/4 Bracket B2 1 Bracket B3 1 1/4 - 1 1/2 Stanchion D4 guard g With Guard (Omit G if guard is not required) options UL Marine listing for HLEMI. ML Standard on HLEMS, HLEMM, HLEMH. Not available on HLEBF, HLEQF SU103 Assembled with lamp

CLASS I DIVISIoN 1

Accessories - order Separately


Catalog Number HLEMg1 HLERSD15 HLERSD30 HLERA15 HLERA30 HLH-EX HLH-g HLH-R HLEMg2 Description Guard for incandescent and fluorescent Standard dome reflector for incandescent and fluorescent Dome reflector for HID lamp sources Angle reflector for incandescent and fluorescent Angle reflector for HID lamp sources Triangular exit sign. Fits HLEMI15, HLEMI20, HLEBF Series, without guard Green inner globe kit fits HLEMI20 (fits over A-21, 150W lamp only) Red inner globe kit fits HLEMI20 (fits over A-21, 150W lamp only) Guard for HID lamp sources

Components
Catalog Number Description Mounting Adapters HLEZA2 3/4 Pendant HLEZA3 1 Pendant HLEZB2 3/4 Wall HLEZB3 1 Wall HLEZD4 1 1/4 Stanchion HLEZD5 1 1/2 Stanchion HLEZX2 3/4 Ceiling HLEZX3 1 Ceiling Housing and globe HLEMI15 150W max. Incandescent HLEMI20 300W max. Incandescent HLEBF13X1 1 - 13W PL Fluorescent HLEBF26X1 2 - 13W PL Fluorescent HLEMS070 70W HPS Quad-Tap HLEMS100 100W HPS Quad-Tap HLEMS151 150W HPS 120V HLEMH070 70W MH Quad-Tap HLEMH100 100W MH Quad-Tap
1 Replace X with 1 = 120V, 4 = 277V.

103

hLE sEriEs
Dimensions
Pendant
3/ " OR 1" 4 NPT CONDUIT

inc/fL/hiD ExpLosion proof


Ceiling
3/ " OR 1" 4 NPT CONDUIT FOUR SIDES 31/ 32" (25)

41/ 2" (114) 4" (102)

4" (102)

.31" (8) 45 4.25" (107)

B A D A

B D

4.75" (120) 7.00" (177)


C

A 14 5/16 HLEMI/HLEBF 364 mm HLEMH/HLEMM/ 15 15/16 HLEMS/HLESX 405 mm

B 13 11/16 348 mm 15 1/16 383 mm

C 7 7/16 189 mm 8 13/16 224 mm

D 10 5/16 262 mm 11 15/16 303 mm

HLEMI/HLEBF HLEMH/HLEMM/ HLEMS/HLESX

A 14 5/16 364 mm 14 5/16 405 mm

B 13 11/16 348 mm 13 11/16 383 mm

C 7 7/16 189 mm 7 7/16 224 mm

D 10 5/16 262 mm 10 5/16 303 mm

CLASS I DIVISIoN 1

Wall
3/ 4"

25 Stanchion

OR 1" NPT CONDUIT FOUR SIDES

B
B A D

C
C

.70" (18) 4.87" (123) .70" (18)

A
.25" DIA. (6) 45 4.62" (117)

14
HLEMI/HLEBF 356 mm HLEMH/HLEMM/ 15 1/8 HLEMS/HLESX 384 mm

13 1/4
337 mm 14 356 mm

13
330 mm 13 1/2 343 mm

2.38" (60) 10.62" (269) 13" (330)

HLEMI/HLEBF HLEMH/HLEMM/ HLEMS/HLESX

A 15 13/16 402 mm 16 13/16 427 mm

B 14 7/16 367 mm 15 15/16 405 mm

C 14 1/2 368 mm 15 381 mm

D 10 5/16 262 mm 11 15/16 303 mm

Angle Dome
C D

Standard Dome
A C B

C B

A 7 3/8 HLEMI/HLEBF 187 mm 8 3/4 HLEMS/HLEMH/HLEMM 222 mm

B 14 356 mm 16 1/8 410 mm

C 3 3/4 95 mm 3 15/16 100 mm

A 7 HLEMI/HLEBF 178 mm 8 3/4 HLEMS/HLEMH/HLEMM 222 mm

B 11 1/2 292 mm 14 3/16 360 mm

C 7 3/4 197 mm 7 3/4 197 mm

D 1 25 mm 1 25 mm

104

inc/fL/hiD ExpLosion proof

hLE sEriEs

Temperature Codes
Class I, Division 1 & 2 HLEMI and HLEBF Series Hazardous Location Application Data
Fixture Series1 HLEMI15 HLEMI15 HLEMI15 HLEMI15 HLEMI15 HLEMI20 HLEMI20 HLEMI20 HLEMI20 HLEMI20 HLEMI20 HLEBF13 HLEBF26 HLEMS070 HLEMS100 HLEMS150 HLEMH070 HLEMH100
Note 1 2

Lamp Type/ Size Max. INC. A-19 INC. A-19 INC. A-19 INC. A-21 INC. A-21 INC. A-23 INC. A-23 INC. PS-25 INC. A-23 INC. PS-25 INC. PS-25 FL (1) PL FL (2) PL HPS S-62 HPS S-54 HPS S-55 MH M-98 MH M-90

Lamp Watts 60 75 100 100 150 100 150 150 200 200 300 13 26 70 100 150 70 100

Class I, Division 1 & 2 Maximum Rated Supply Wire Surface Temp. w/o Reflector UL 595 Paint Spray Type 4 Ambient Suitable For Temp. I.D. Actual UL/CSA Listed2 Suitability UL (Hose-Down)2 C C Min. Temp. groups 40 75 T6 79 C,D Yes No Yes 40 75 T4A 103 C,D Yes No Yes 40 75 T4A 103 C,D Yes No Yes 40 75 T4A 101 C,D Yes No Yes 40 75 T4 123 C,D Yes No Yes 40 90 T4A 107 C,D Yes No Yes 40 90 T4 132 C,D Yes No Yes 40 90 T4 126 C,D Yes No Yes 40 90 T3C 146 C,D Yes No Yes 40 90 T3C 154 C,D Yes No Yes 40 90 T3 190 C,D Yes No Yes 40 75 T6 62 C,D No Yes Yes 40 75 T6 62 C,D No Yes Yes 40 75 T6 83 C,D Yes Yes Yes 40 75 T5 99 C,D Yes No Yes 40 75 T4A 119 C,D Yes No Yes 40 75 T5 95 C,D Yes Yes Yes 40 75 T4A 101 C,D Yes No Yes

CLASS I DIVISIoN 1

Fixtures approved for mounting with lamp base up only. Do not install where marked operating temperature exceeds ignition temperature of hazardous atmosphere. For UL 1598A Marine Outdoor and UL/CSA Type 4 Fixture Label, add suffix ML to fixture catalog number.

Class II, Division 1 & 2 HLEMI and HLEBF Series Hazardous Location Application Data
Fixture Series1 HLEMI15 HLEMI15 HLEMI15 HLEMI15 HLEMI15 HLEMI20 HLEMI20 HLEMI20 HLEMI20 HLEMI20 HLEMI20 HLEBF13 HLEBF26 HLEMS070 HLEMS100 HLEMS150 HLEMH070 HLEMH100
Note 1 2

Class II, Division 1 & 2 Maximum Surface Temp. Rated Supply Wire Lamp Type/ Lamp UL/CSA w/Reflector UL/CSA w/o Reflector Ambient Suitable For Size Max. Watts Temp. I.D. Actual Temp. I.D. Actual C C Min. Temp. Temp. INC. A-19 60 40 75 T3C 132 T3C 132 INC. A-19 75 40 75 T3A 163 T3A 162 INC. A-19 100 40 75 T3A 163 T3A 162 INC. A-21 100 40 75 T3A 172 T3A 172 INC. A-21 150 40 75 N/A 192 T3 192 INC. A-23 100 40 90 T3A 166 T3A 166 INC. A-23 150 40 90 T3 196 T3A 178 INC. PS-25 150 40 90 N/A N/A N/A N/A INC. A-23 200 40 90 N/A N/A N/A N/A INC. PS-25 200 40 90 N/A N/A N/A N/A INC. PS-25 300 40 90 N/A N/A N/A N/A FL (1) PL 13 40 75 T6 69 T6 66 FL (2) PL2 26 40 75 T6 69 T6 66 HPS S-62 70 40 75 T4A 116 T4A 116 HPS S-54 100 40 75 T3B 161 T3B 161 HPS S-55 150 40 75 T3B 180 T3B 180 MH M-98 70 40 75 T4 121 T4 121 MH M-90 100 40 75 T3C 150 T3C 153

UL/CSA groups E,F,G E,F E,F E,F E,F E,F E,F No No No No E,F,G E,F,G E,F,G E,F,G E,F E,F,G E,F,G

Class III Div. 1 & 2 UL/CSA Suitability Yes No No No No No No No No No No Yes Yes Yes Yes No Yes Yes

Fixtures approved for mounting with lamp base up only. Do not install where marked operating temperature exceeds ignition temperature of hazardous atmosphere. 13 Watts per lamp.

105

mogUL bAsE ExpLosion proof Features


For use in classified areas such as paint manufacturing, munitions facilities, chemical and petrochemical, oil and gas production, and marine loading terminals. Compact size for mogul base HID lamps. Mounting choices of pendant, ceiling, 25 stanchion or 90 wall mount with wireless design for quick installation. Factory sealed no external seal required. Available with guard, standard dome or 25 reflector. Pulse Start lamps available (consult factory). Housing, Mounting Adaptor Copper-free (<0.4%) die-cast aluminum with powder polyester finish, electrostatically applied. Guard EZG1 = Copper-free die-cast aluminum; VMAG-40 = Plated Steel. Hardware 316 stainless steel. Reflectors Fiberglass reinforced polyester or spun aluminum (deep dome) with baked white enamel finish. UL844 Standard: Class I, Div. 1, Groups C,D; Class II, Div. 1/2, Groups E, F, G; Class III, Div. 1/2. UL1598A Marine Outdoor; NEMA 3, 4, 4X, 7 (C, D), 9 (E, F, G); UL1598 Wet Location.

hLEZ sEriEs

ordering Information

Example: HLEZ
Series

H
Lamp Type

17
Watts

Q
Volts

A2
Mount

G
guard

Q
options

CLASS I DIVISIoN 1

Series HLEZ HLEZ Series Lamp Type High Pressure Sodium S Metal Halide H Mercury Vapor M Pulst Start Metal Halide P Wattage 50W HPS 05 70W HPS/MH 07 100W HPS/MH/MV 10 150W HPS 15 17 175W MH/MV/MHP 25 250W HPS/MH/MV/MHP 32 320W MHP 35 350W MHP 40 400W HPS/MH/MV/MHP

Voltage o Quadri-Volt, 60 Hz (120, 208, 240, 277V) 480V, 60 Hz 5 Tri-Tap Canada (120, 277, 347V), 6 60 Hz 8 220/240V, 50 Hz 9 Special (specify) Mounting Type A2 3/4 Pendant A3 1 Pendant X2 3/4 Ceiling X3 1 Ceiling B2 3/4 Bracket B3 1 Bracket D4 1 1/4 - 1 1/2 Stanchion

guard g options Q R BP PS

With Guard (Omit G if guard is not required)

Auxiliary Quartz Standby Instant Restrike (150W HPS Max.) Ballast protector Paint Spray (50, 70, 100W HPS, 100W MV, 70, 100W MH) SU103 Assembled with lamp

Dimensions
3/4" or 1" NPT Conduit

G
C

Pendant
A

B E

Pendant Mounting Hub

A D B

D C

70-250W1 250-400W2

A 22 558 mm 26 1/4 666 mm

B 21 1/4 539 mm 24 1/4 615 mm

C 11 1/4 285 mm 11 1/4 285 mm

D 18 457 mm 22 1/4 565 mm


G

E 10 1/2 267mm 10 1/2 267mm

F 4 102 mm 4 102 mm

g 4 1/2 114 mm 4 1/2 114 mm

A 5 1/2 133 mm

B 4 5/8 117 mm

C 1/4 dia. 6 mm

D 45 N/A

3/4" or 1" NPT Conduit, four sides

Ceiling

A F B D C

Ceiling Mounting Hub

70-250W1 250-400W2

A 22 558 mm 26 1/4 666 mm

B 21 1/4 539 mm 24 1/4 615 mm

C 11 1/4 285 mm 11 1/4 285 mm


1 2

D E F 18 4 10 1/2 457 mm 102 mm 267 mm 22 1/4 4 10 1/2 565 mm 102 mm 267 mm

g 15/16 25 mm 15/16 25 mm

A 4 1/4 107 mm

B C 4 3/4 7 120 mm 177 mm

D 5/16 8 mm

E 45 N/A

106

70, 100, and 150 Watt HPS; 175 and 250 Watt MH; 100, 175, 250 Watt MV. 250 and 400 Watt HPS and 400 Watt MH and MV.

hLEZ sEriEs
Dimensions
Bracket Arm
3/4" or 1" NPT Conduit Four Sides

mogUL bAsE ExpLosion proof


Bracket Mounting Hub

D B

A D E

70-250W1 250-400W2

A 22 7/8 580 mm 26 7/8 682 mm

B 22 1/8 561 mm 24 7/8 631 mm

C 16 3/4 425 mm 16 3/4 425 mm

D 18 457 mm 22 1/4 565 mm

E 10 1/2 267 mm 10 1/2 267 mm

A 11/16 18 mm

B 10 5/8 269 mm

C 13 330 mm
A B

D 2 3/8 60 mm

E 4 7/8 123 mm

Stanchion Mounting Hub

25 Stanchion
B A

70-250W1 250-400W2

A 24 7/8 631 mm 28 1/2 724 mm

B 24 609 mm 26 11/16 678 mm

C 19 503 mm 21 1/2 546 mm A B 9 5/8 6 1/4 244 mm 158 mm


C D E
1 1/2" or 1 1/4" NPT Conduit

CLASS I DIVISIoN 1

1 2

70, 100, and 150 Watt HPS; 175 and 250 Watt MH; 100, 175, 250 Watt MV. 250 and 400 Watt HPS and 400 Watt MH and MV.

C 2 5/8 66 mm

D 1 5/16 33 mm

E 25 N/A

F 4 3/4 120 mm

Accessories and Replacement Parts - order Separately


Replacement globe and globe Support Assemblies
Catalog Number HLEZgS1 Series HLEZS HLEZM HLEZH HLEZH HLEZS HLEZM HLEZH HLEZH Series HLEZS HLEZM HLEZH HLEZH HLEZS HLEZM HLEZH HLEZH Lamp Type HPS MV MH MHP HPS MV MH MHP Lamp Type HPS MV MH MHP HPS MV MH MHP Wattage 50, 70, 100, 150 100, 175, 250 70, 100, 175, 250 175, 250, 320, 350, 400 250, 400 400 400 320, 350, 400 Wattage 50, 70, 100, 150 100, 175, 250 70, 100, 175, 250 175, 250, 320, 350, 400 250, 400 400 400 320, 350, 400 HLEZgS1 HLEZgS2

HLEZgS2

guards
Catalog Number HLEZg1

HLEZg1

VMAg-40

VMAg-40

HLEZG1 Guard is cast aluminum. VMAG-40 Guard is plated steel.

Replacement Connection Blocks


Catalog Number HLEZTB Catalog Number HLEZA2 HLEZA3 HLEZX2 HLEZX3 HLEZB2 HLEZB3 HLEZD4 HLEZD5 Description Female Mounting Pendant Mount Pendant Mount Ceiling Mount Ceiling Mount Bracket Mount Bracket Mount Stanchion Mount Stanchion Mount Hub Size 3/4 1 3/4 1 3/4 1 1-1/4 1-1/2

HLEZTB

Mounting Boxes
Pendant Ceiling Bracket Stanchion

107

hLEZ sEriEs
mogUL bAsE ExpLosion proof

ordering Information
Ballast, globe and glass Support Assemblies
Catalog Number HLEZS07X HLEZS10X HLEZS15X HLEZS25X HLEZS40X HLEZH17X HLEZH25X HLEZH40X HLEZM10X HLEZM17X HLEZM25X HLEZM40X HLEZP17X HLEZP25X HLEZP32X HLEZP35X HLEZP40X Watts 70 100 150 250 400 175 250 400 100 175 250 400 175 250 320 350 400 A 10 1/4 260 mm Deep Dome
A C B

A 9 7/8 250 mm

B 20 5/8 525 mm

C 10 3/4 273 mm

Standard Dome
B A C B

Angle Dome
A

D C

CLASS I DIVISIoN 1

Note

Reflectors
Catalog Number VMPSD40 VMPA40 HRD400

To specify voltage, replace X with 0 = Quad-Tap, 5 = 480V, 6 = Tri-Tap (120, 277, 347V), 8 = 220/240V 50Hz.

Description Standard Dome, Polyester reinforced fiberglass Angle Dome, Polyester reinforced fiberglass Deep Dome, Baked white enamel aluminum

B 16 7/8 428 mm

C 5 1/2 139 mm

A 10 1/4 260 mm

B 2 1/2 63 mm

C 16 7/8 428 mm

D 10 5/8 270 mm

Hazardous Location T-Ratings


Fixture Series: HLEZ - Metal Halide, Class I Division 1 & 2
Lamp Watts 70 70 70 100 100 100 175 175 250 250 400 Rated Ambient C 40 55 65 40 55 65 40 55 40 55 40 Supply Wire Suitable For C Min. 85 85 85 85 85 85 85 85 85 85 85 Class I, Division 1 & 2 Maximum Surface Temp. UL/CSA Temp. ID Temp. ID UL/CSA w/o Qtz w/Qtz1 groups T4A N/A C,D T4A N/A C,D T4A N/A C,D T4A N/A C,D T4A N/A C,D T4A N/A C,D T4 T3C C,D T4 N/A C,D T3C T3C C,D T3C N/A C,D T3A T3A C,D UL 595 Marine Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes UL Paint Spray Suitability4 Yes No No Yes No No No No No No No Class III Div. I & 2 UL/CSA Suitability w/o QTZ w/QTZ3 Yes Yes Yes Yes Yes Yes Yes Yes No No No No No No No No Yes No No No

Fixture Series: HLEZ - Metal Halide, Class II Division 1 & 2, Class III Division 1 & 2
Lamp Watts 70 70 70 100 100 100 175 175 250 400 Rated Ambient C 40 55 65 40 55 65 40 55 40 40
1 2 3 4

Supply Wire Suitable For C Min. 85 85 85 85 85 85 85 85 85 85

Class II, Division 1 & 2 Maximum Surface Temp. UL/CSA UL/CSA groups Temp. ID Temp. ID w/o Qtz w/Qtz3 w/o Qtz w/Qtz3 T4A N/A E,F,G Yes T4A N/A E,F,G Yes T4A N/A E,F,G Yes T4A N/A E,F,G Yes T4A N/A E,F,G Yes T4A N/A E,F,G Yes T3C2 T3A2 E,F,G E,F T3C2 N/A E,F,G N/A N/A N/A N/A N/A N/A N/A N/A N/A

108

Instant restrike limited to 55 ambient maximum. Temperature Code I.D. marked are listed for simultaneous use in Class I, Groups C,D and Class II, Groups E,F,G Fixtures are not suitable for Class III, Division 1 and 2 when supplied with auxiliary quartz. Suitable for locations having deposits of readily combustible paint residue.

hLEZ sEriEs
Hazardous Location T-Ratings
Fixture Series: HLEZM - Mercury Vapor, Class I, Division 1 & 2
Lamp Watts 100 100 175 175 250 400 Rated Ambient C 40 55 40 55 40 40 Supply Wire Suitable For C Min. 85 85 85 85 85 85 Class I, Division 1 & 2 Maximum Surface Temp. NEC/CEC Temp. ID Temp. ID UL/CSA w/o Qtz w/Qtz3 groups T4 T3C C,D T4 N/A C,D T4 T3C C,D T4 N/A C,D T3C T3C C,D T3A T3A C,D UL 595 Marine Yes Yes Yes Yes Yes Yes UL Paint Spray Suitability4 Yes No No No No No

mogUL bAsE ExpLosion proof

Fixture Series: HLEZM - Mercury Vapor, Class II Division 1 & 2, Class III Division 1 & 2
Lamp Watts 100 100 175 175 250 400 Rated Ambient C 40 55 40 55 40 40 Supply Wire Suitable For C Min. 85 85 85 85 85 85 Class II, Division 1 & 2 Maximum Surface Temp. NEC/CEC NEC/CEC groups Temp. ID Temp ID w/o Qtz w/Qtz3 w/o Qtz w/Qtz3 T3C2 T3A2 E,F,G E,F T3C2 N/A E,F,G N/A T3C T3A2 E,F,G E,F T3C N/A E,F,G N/A N/A N/A N/A N/A N/A N/A N/A N/A Class III, Division 1 & 2 UL/ CSA Suitability w/o Qtz w/Qtz3 Yes Yes Yes Yes No No Yes No No No No No

CLASS I DIVISIoN 1

Fixture Series: HLEZ - High Pressure Sodium, Class I Division 1 & 2


Lamp Watts 70 70 70 100 100 100 150 150 150 250 250 400 Rated Ambient C 40 55 65 40 55 65 40 55 65 40 55 40 Supply Wire Suitable For C Min. 85 85 85 85 85 85 85 85 85 85 85 85 Class I, Division 1 & 2 Maximum Surface Temp. NEC/CEC Temp. ID Temp. ID UL/CSA w/o Qtz. w/Qtz3 groups T4A T4 C,D T4A N/A C,D T4A N/A C,D T4A T4 C,D T4A N/A C,D T4A N/A C,D T4A T4 C,D T4A N/A C,D T4 N/A C,D T3C T3C C,D T3C N/A C,D T3C T3C C,D UL 1598A Marine Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes UL/CSA Type3 (Raintight) Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes UL Paint Spray Suitability4 Yes No No Yes No No No No No No No No

Fixture Series: HLEZ - High Pressure Sodium, Class II Division 1 & 2, Class III Division 1 & 2
Lamp Watts Rated Ambient C 40 55 65 40 55 65 40 55 65 40 55 40 Supply Wire Suitable For C Minimum 85 85 85 85 85 85 85 85 85 85 85 85 Class II, Division 1 & 2 Maximum Surface Temp. NEC/CEC UL/CSA groups Temp. ID Temp. ID w/o Qtz. w/Qtz3 w/o Qtz. w/Qtz3 T3C2 T3B2 E,F,G E,F,G T3C2 N/A E,F,G N/A T3B2 N/A E,F,G N/A T3C2 T3B2 E,F,G E,F,G T3C2 N/A E,F,G N/A T3B2 N/A E,F,G N/A T3C2 T3B2 E,F,G E,F,G T3C2 N/A E,F,G N/A T3B2 N/A E,F,G N/A T32 T32 E,F E,F N/A N/A N/A N/A N/A N/A N/A N/A Class III, Division 1 & 2 NEC/CEC Suitability w/o Qtz. w/Qtz.1

70 70 70 100 100 100 150 150 150 250 250 400


1 2 3 4

Yes Yes Yes Yes Yes Yes Yes Yes Yes No No No

Yes No No Yes No No Yes Yes Yes Yes No No

Instant restrike limited to 55 ambient maximum. Temperature Code I.D. marked are listed for simultaneous use in Class I, Groups C, D and Class II, Groups E, F, G. Fixtures are not suitable for Class III, Division 1 and 2 when supplied with auxiliary quartz. Suitable for locations having deposits of readily combustible paint residue.

109

hL-hfx sEriEs fLUorEscEnt


ExpLosion proof

Features

For use in hazardous locations where flammable gases, vapors and combustible dusts are present. Applications include paint spray booths, oil and gas production, petrochemical and other hazardous, corrosive facilities. Relamping from either end permits easy access, speed and flexibility in relamping. Spring loaded sockets on both lamp ends provide positive electrical contact and improved vibration resistance. Threaded O-Ring gasketed covers provide easy access to lamp chambers, ballast and wiring compartment. UL Listed for use in paint spray booths. Ballast housing and end caps copper-free (>0.4%) aluminum. External hardware SS 316. Reflectors Extruded aluminum with white baked enamel finish. Removable for cleaning. Wire Guard accessory - SS316. UL 844: Class I, Div. 1/2, Groups C,D; Class II, Div. 1/2, Groups E, F, G; Class III, Div. 1/2. UL 1598A Marine Outdoor; NEMA 3, 4X, 7 (C, D), 9 (E, F, G).

ordering Information

Example: HLHFX
Series

2
Lamp Current

R
Volts

1
# of Lamps

B
options

CLASS I DIVISIoN 1

Series HLHFX Hazardous Location Fluorescent Lamp Current 265 MA, 32W T82 265 (0F Starting, Electronic) 430 MA, 40W RS 430 (50F Starting, Electronic)1 800 800 MA, 60W RS HO (-20F Starting) 1500 1500 MA, 110W RS VHO (-20F Starting)

Voltage 120V (430MA-1500MA only) 1 277V (430MA-1500MA only) 4 220V 60Hz 7 220-277V 50/60Hz 8 120-277V 50/60Hz2 30 Number of Lamps 2 lamps 2 3 lamps 3 4 lamps 4

options FB Individually in-line fused ballast (not marine) WL With lamps supplied
1 2 430 MA Ballasts 60F start with 34W lamps. 265 MA Electronic Ballast standard as universal voltage.

Accessories - order Separately


Catalog Number HLF-Wg2 HLF-Wg3 Description 2 & 4 lamp, stainless steel wire guard 3 lamp, stainless steel wire guard

Weights
Fixture 2 Lamp 3 Lamp 4 Lamp lbs. (kg) 47.7 (95.4) 63 (126) 99.9 (199.8)

Two-lamp

Three-lamp

Four-lamp

F D E G
A 52 13/16 1341 mm B 48 3/8 1229 mm C 9 13/32 239 mm

B J C A
E 11 279 mm F 45 g 15 5/8 397 mm H 9 13/32 239 mm I 23 584 mm J 10 1/8 257 mm

H I
D 9 13/32 239 mm

110

Features

mAgnULitEr mvh

EncLosED/gAskEtED

For use in harsh, hazardous, marine, and corrosive environments such as petrochemical facilities, wastewater and sewage treatment plants, and salt water / corrosive enviroments. Available up to 1000W HPS or MH, 1000W units include lamp. Restricted Breathing AExnR / ExnR (RB option) enables lower T-Ratings at higher wattages. Refer to T-Rating table for availability. Elevated ambient EA option available for specific wattages. Removable Powr-Panl ballast tray (up to 400W excluding RB option). Varying beam spreads utilizing vertical or horizontal lamp mounting. Housing, door frame Copper-free (<0.4%) aluminum. Lens thermal shock, impact resistant. Trunnion Hot dipped galvanized steel. Hardware HubbellGard screws. UL 844 Standard: Class I, Div. 2 Groups A, B, C, D; Class I, Zone 2 Groups IIC,IIB, IIA; AExnR/ExnR Restricted Breathing. UL 1598 and UL 1598A Marine Outdoor; NEMA 3, 4X; IP66.
Catalog Number MVH-0150S-26X1 MVH-0250S-26X1 MVH-0400S-26X1 MVH-1000S-26X2 MVH-0175H-26X3 MVH-0250H-26X3 MVH-0400H-26X3 MVH-1000H-26X2 MVH-0250S-23X1 MVH-0400S-23X1 MVH-0250H-23X3 MVH-0400H-33X3
1 2 3 Note

Photometry NEMA/IES H x V 7(144) x 6(113) 7(144) x 6(113) 7(144) x 6(117) 6(130) x 6(114) 7(145) x 6(114) 7(145) x 6(114) 7(146) x 6(119) 6(118) x 6(112) 5(73) x 3(32) 5(73) x 3(32) 3(45) x 3(31) 3(44) x 3(37)

Lamp Type/Wattage Vertical Lamp 150W HPS 250W HPS 400W HPS 1000W HPS 175W MH 250W MH 400W MH 1000W MH Horizontal Lamp 250W HPS 400W HPS 250W MH 400W MH

Weight lbs. (kg) 28 (12.7) 39 (17.7) 40 (18.1) 55 (24.9) 28 (12.7) 30 (13.6) 32 (14.5) 42 (19) 39 (17.7) 40 (18.1) 30 (13.6) 32 (14.5)

EPA ft (m) 2.3 (0.2) 2.3 (0.2) 2.3 (0.2) 2.3 (0.2) 2.3 (0.2) 2.3 (0.2) 2.3 (0.2) 2.3 (0.2) 2.3 (0.2) 2.3 (0.2) 2.3 (0.2) 2.3 (0.2)

CLASS I DIVISIoN 2

Replace X with voltage, 5-480V; 6-Tri-Tap(120/277/347V); 8-Quad-Tap(120/208/240/277V); E-220/240V 50Hz. 1000W units include lamp as standard. MH lamp is MH 1000/U/BT37. HPS lamp is Catalog 1000S52/ED37 from Phillips. Mercury Vapor lamps may be used if desired. Order mounting accessories separately. See pages 510-511.

options - order Separately


Part Number F(X) L RB EA
1 2 3 4

Description Fusing - single 120/277/347V; Double 208/240/480V; fuse included (specify voltage)1, 2, 3 Lamp shipped separately4 Restricted Breathing allowing for lower T-Ratings. Housing provided with test port entry. See T-Rating chart for availability. Elevated Ambient capability. Consult factory.

Replace X with voltage. 1-120V; 2-208V; 3-240V; 4-277V; 5-480V; 6-347V; E-220/240V 50Hz. Fused units do not carry UL 1598A Marine Outdoor listing. Not CSA certified with F option. 1000W units include lamp as standard. MH lamp is MH 1000/U/BT37. HPS lamp is Catalog 1000S52/ED37 from Phillips.

Hazardous Location Temperature Ratings


Wattage Vertical Lamp Horizontal Lamp Class I, Division 21 Class I, Zone 21 Class I, Division 21 Class I, Zone 21 Max. oper. Temp. Max. oper. Temp. Max. oper. Temp. Max. oper. Temp. Temp. Rating Code Temp. Rating Code Temp. Rating Code Temp. Rating Code High Pressure Sodium 260 T2B 300 T2 450 T1 450 T1 3253 450 T1 450 T1 450 T1 3503 450 T1 450 T1 450 T1 450 T1 450 T1 Metal Halide 3253 450 T1 450 T1 450 T1 3253 450 T1 450 T1 450 T1 450 T1 450 T1 Mercury 3 350 450 T1 3503 450 T1 3503 450 T1
1 2 3 4 Lamp temperature data was obtained in 40C ambient operating conditions. Consult factory for elevated ambient capabilities. Represents actual maximum lamp temperature rating. To maintain T-Ratings, aiming angle is limited to 35 - 135 (no horizontal mounting).

Restricted Breathing option ExnR, AExnR2 Temp. Code T4 T3 T3 T2 T2 T3 T3 T3

150W 250W 400W 1000W4 250W 400W 1000W4 175W 250W 400W

111

pErimALitEr pgm2
hAZArDoUs wALLpAck

Features
Typical uses are walkway, catwalk, perimeter and security lighting. 5:1 spacing to mounting height ratio minimizes fixture requirements. Hinging front door provides full front access. -40F starting for HPS; -20F for MH. 40C ambient. Housing Copper-free (<0.4%) aluminum with bronze Lektrocote finish. Lens Thermal shock and impact resistant. Fasteners HubbellGard hex head. Two NPT conduit entries on either side. UL844 Standard: Class I, Div. 2, Groups A, B, C, D; Zone 2, Groups IIC, IIB, IIA. NEMA 4X. UL1598 Wet Location.

Catalog Number PgM2-H078 PgM2-H108 PgM2-H178 PgM2-S078 PgM2-S108 PgM2-S158


Note

Wattage & ANSI Code 70W (M-98) 100W (M-90) 175W (M-57) 70W (S-62) 100W (S-54) 150W (S-55)

Voltage/Ballast Metal Halide Quad-Tap Quad-Tap Quad-Tap High Pressure Sodium Quad-Tap Quad-Tap Quad-Tap

Weight lbs. (kg) 23 (10.4) 24 (10.9) 25 (11.3) 24 (10.9) 25 (11.3) 25 (11.3)

T-Code @ 40C T2D - 215C T2D - 215C T2B - 260C T3 - 200C T3 - 200C T2B - 260C

CLASS I DIVISIoN 2

For voltage, change last character in catalog number. Example: PGM2-H178 to PGM2-H175; 5 = 480V, 6 = Tri-Tap 120/277/347V, E = 230V 50Hz.

Accessories - order Separately


Catalog Number PgPS PgWg PVLV Description Clear polycarbonate shield for lens protection Wire guard, cadmium plated steel Full cutoff visor. Formed bronze aluminum

Dimensions
A C

A 14 1/2 368 mm

B 14 356 mm

C 7 1/8 181 mm

D 6 152 mm

1/2 feed thru surface hub conduit

112

kEmLUx iii kh sEriEs


Features
For use in corrosive, harsh, hazardous applications such as chemical, petrochem, marine, power generation, pharmaceutical, or food processing plants. Electro-Reg ballast provides long life, high lumen maintenance metal halide light source for low operating and maintenance costs. Mogul base socket. Cover selection of rigid pendant, ceiling, wall, right angle stanchion, and 25 stanchion in varying threaded NPT entries. Minimum starting temp of -20F for MV/MH and -40F for HPS. Copper-free (<0.4%) aluminum housing, cover and guard with Lektrocote powder polyester paint finish. Color is tan. Optic choices of impact resistant glass globe, sym./asym. glass refractors, dome/angle FRP reflector, 19 enclosed reflector, and polycarbonate enclosed low bay. Unit shown with optional globe guard. Modular design permits selection of cover, body, globe, guard and reflector. UL844 Standard: Class I, Div. 2, Groups A, B, C, D; Class II, Div. 1/2, Groups E, F, G; Class III, Div. 1/2. UL 1598A Marine Outdoor; NEMA 4X and IP66 with K-G globe; 40C ambient listed; UL1598 Wet Location.

EncLosED/gAskEtED

ordering Information
Series KH Kemlux III KH Tank Type C Low Wattage Mogul Base 5" D Low Wattage Mogul Base 8" E High Wattage Mogul Base 8" Lamp Type S High Pressure Sodium H Metal Halide P Pulse Start Metal Halide M Mercury Vapor Wattage 05 50 watt (HPS) 07 70 watt (HPS, MH) 10 100 watt (HPS, MH, MV) 12 125 watt (Pulse Start MH) 15 150 watt (HPS, Pulse Start MH) 17 175 watt (MH, Pulse Start MH, MV) 20 200 watt (HPS) 25 250 watt (HPS, MH, Pulse Start MH) 32 320 watt (Pulse Start MH) 35 350 watt (Pulse Start MH) 40 400 watt (HPS, MH, Pulse Start MH, MV) Voltage (@ 60 HZ) 0 Quadri-Volt (120, 208, 240, 277V) 5 480V 6 Tri-Tap Canada (120, 277, 347V) 7 220V 8 220/240V 50 Hz Mounting Type A Pendant X Ceiling B Wall Bracket C Cone Top D Stanchion 25 S Stanchion Straight 90 N None (mount ordered separately)1
1 2 3 4 5 6 NN mount ordered separately. Tuffskin is a registered trademark of Thomas Mfg. Corp. Teflon is a registered trademark of DuPont, Inc. AEx nAR Restricted Breathing. Order guards for Spin-Tops and KER40 separately. Fusing not for Marine or Canadian installations. 7 8 9 10

KH
Series

D
Tank

H
Lamp

40
Wattage

0
Voltage

A
Mount

2
Entry

GL
optic

G
guard

Entry (mounts available) 34" NPT (A, B, C, X) 2 3 1" NPT (A, B, C, X) 4 114" NPT (D, S) 5 112" NPT (D, S) 34" NPT 5-hub (X) 6 7 1" NPT 5-hub (X) N None (mount ordered separately)1 optics gL Globe R1 Type I Glass Refractor R3 Type III Glass Refractor (KHDonly) R5 Type V Glass Refractor ER Enclosed Reflector (KHD & KHE only) EP Polycarbonate Shielded Enclosed Reflector (KHD & KHE only)9 S2 Type II 12" Spin-Top Refractor S8 Type V 8" Spin-Top Refractor (KHC only) S5 Type V 12" Spin-Top Refractor P5 Type V Plastic Spin-Top Refractor (KHC only) Fg Tuffskin Coated Globe2 Tg Teflon Coated Globe3 T1 Teflon Coated Globe Type I Glass Refractor3 T3 Teflon Coated Globe Type III Glass Refractor (KHD only)3 T5 Teflon Coated Globe Type V Glass Refractor3 T2 Teflon Coated Globe Type II 12" Spin-Top Refractor3 T8 Teflon Coated Globe Type V 8" Spin-Top Refractor (KHC only)3 TV Teflon Coated Globe Type V 12" Spin-Top Refractor3 guard g Globe Guard N No Guard5
Photocells for Class I, Div. 2 only. Field connection to proper tap in case of Multitap ballasts. Not for use with wall or straight (90) stanchion. QX = Quick Disconnect. Allows easy tank removal for maintenance. Electrician simply unplugs de-energized ballast from supply circuit.

options BP Ballast Protector (250-400W HPS only) F1 Fusing - single 120V 60Hz6 F2 Fusing - double 208V 60Hz6 F3 Fusing - double 240V 60Hz6 F4 Fusing - single 277V 60Hz6 F5 Fusing - double 480V 60Hz6 F6 Fusing - single 347V 60Hz6 F7 Fusing - double 220V 60Hz6 F8 Fusing - double 230V 50Hz6 P1 Photo Cell Factory 120V 7, 8 P2 Photo Cell Factory 208-277V (must specify voltage on order)7, 8 P3 Photo Cell Factory 347V7, 8 Q1 Quick Disconnect wired at ballast to 120V10 Q2 Quick Disconnect wired at ballast to 208V10 Q3 Quick Disconnect wired at ballast to 240V10 Q4 Quick Disconnect wired at ballast to 277V10 Q5 Quick Disconnect wired at ballast to 480V10 Q6 Quick Disconnect wired at ballast to 347V10 Q7 Quick Disconnect wired at ballast to 220V10 Q8 Quick Disconnect wired at ballast to 230V10 TB Terminal Blocks AS Assembled Fixture with standard lamp AD Assembled Fixture with DAT Dual-Arc-Tube lamp (250, 400W HPS only CS Component Pack with standard lamp CP Component Pack - no lamp NR Restricted Breathing4

CLASS I DIVISIoN 2

5 1/2 optic Compact Profile Medium Base

KHA

7 3/4 optic Compact Profile Medium Base

KHB

5 1/2 optic Low Wattage Mogul Base

KHC

7 3/4 optic Low Wattage Mogul Base

KHD

7 3/4 optic High Wattage Mogul Base

KHE

113

kEmLUx iii kh sEriEs


EncLosED/gAskEtED
Hub Size 3/4 1 1-1/4 1-1/2 M-20

Kemlux III Mounting Splice Boxes


Pendant KHA2B KHA3B Flexible Pendant KHF2B KHF3B Ceiling 4-Hub KHX2B KHX3B KHX8B Catalog Number Ceiling Wall 5-Hub KHX6B KHB2B KHX7B KHB3B KHX9B Cone Top KHC2B KHC3B 25 Stanchion KHD4B KHD5B 90 Stanchion KHS4B KHS5B

Kemlux III 50-600W Ballast Tank Assemblies


Catalog Number High Pressure Sodium Low Wattage Watts 50 70 100 150 175 200 250 320 350 400 5-1/2 KHCS05X KHCS07X KHCS10X KHCS15X 7-3/4 KHDS05X KHDS07X KHDS10X KHDS15X High Wattage 7-3/4 KHES20X KHES25X KHES40X Metal Halide Low Wattage 5-1/2 KHCH07X KHCH10X KHCH15X KHCH17X KHCH25X 7-3/4 KHDH07X KHDH10X KHDH15X KHDH17X KHDH25X High Wattage 7-3/4 KHEH40X Pulse Start Metal Halide Low Wattage 5-1/2 7-3/4 High Wattage 7-3/4 KHEP25X KHEP32X KHEP35X KHEP40X Mercury Vapor Low Wattage 5-1/2 7-3/4 High Wattage 7-3/4 KHEM40X

CLASS I DIVISIoN 2

KHCP15X KHDP15X KHCP17X KHDP17X KHCP20X KHDP20X

KHCM10X KHDM10X KHCM17X KHDM17X KHCM25X KHDM25X

Note Replace X with voltage: 0-Quad, 6-Tri, 5-480V.

optics

Kg17

guards

KR175 KR171

KZRg1550

KZRg2550 KZRg2520

Kg25

KHR255 KHR253 KHR251

Kg40

KER40

KZRg4050 KZRg4020

KEP40

KHAg172

KHAg172

KRWg84

KRWg4

KAg25S3

KAg25S3

KAg40S3

KERg3

KRWg4

Wg-23

Reflectors

KPSD40 Standard Dome Fiberglass White Reflector Dia: 16


1 2 3 4

KPA40 Angle Fiberglass White Reflector Dia: 16

HRD400 Deep Aluminum White Reflector Dia: 21

HRD400ALZ Deep Aluminum Anodized Finish Reflector Dia: 21

KAgBC Bottom Closure for KAg25S/SAg40S

KHC 12 Spin Tops ship with a mogul-to-mogul extender for improved photometrics. Standard material, copper-free aluminum painted. Standard material, 316 stainless steel. Standard material, plated steel.

114

kEmLUx iii kh sEriEs


KHC/KHD Series Thermal Performace Data Class I Division 2 groups A, B, C, D / Zone 2 groups IIC, IIB, IIA
Description KHC Series1 Lamp Ambient globe globe w/ Refractors KR Type Watts KZRg 8 KZRg 12 C only reflector HPS 50 40 T3 T3 T3 T3 T3A HPS 70 40 T3 T3 T3 T3A T3A HPS 100 40 T2D T2D T2D T3 T2D HPS 150 40 T2B T2B T2B T2B T2B MH 70 40 T3B T3A T3B T3C T3B MH 100 40 T3 T3 T3 T3A T3C MH 175 40 T2A T2A T2A T2B T2B MH 250 40 325C 325C 325C T2 T2 MHP 150/175 40 T2A T2A T2A T2B T2B MHP 200 40 T2A T2A T2A T2B T2B MV 100 40 T2B T2B T2B T2B T2B MV 175 40 T2 T2 T2 T2A T2A MV 250 40 350C 350C 350C 350C 350C
1 KHC Series accepts 5 1/2 threaded optics. KHD Series accepts 7 3/4 optics.

EncLosED/gAskEtED

KHD Series1 globe globe w/ Refractor Enclosed Reflectors Supply KER40 KEP40 Wire C KR only reflector T3C T3C T3C T3C T3C 60 T3A T3A T3A T3A T3A 60 T3 T3 T3 T3 T3 75 T2B T2B T2B T2B T2B 90 T3C T3C T3C T3C T3C 75 T3A T3A T3A T3A T3A 75 T2B T2B T2B T2B T2B 90 T2 T2 T2 T2 T2 90 T2B T2B T2B T2B T2B 90 T2B T2B T2B T2B T2B 90 T2B T2B T2B T2B T2B 75 T2A T2A T2A T2A T2A 90 350C 350C 350C 350C 350C 110

KHC/KHD Series Thermal Performance Data Class II Divisions 1 & 2 groups E, F, g & Class III2
Description KHC Series1 Lamp Refractors Ambient globe globe w/ KR Type Watts KZRg 8 KZRg 12 C only reflector HPS 50 HPS 70 HPS 100 HPS 150 MH 70 MH 100 MH 175 MH 250 MHP 150/175 MHP 200 MV 100 MV 175 MV 250
1 2 +

40 40 40 40 40 40 40 40 40 40 40 40 40

T3C T4A T3C T3C T3C T3C T3C

T3C T4A T3C T3C T3C T3C T3C

T3C T4A T3C T3C T3C T3C T3C

T3C T4A T3C T3C T3C T3C + T3C + +

T3C T4A T3C T3C T3C T3C + + + + T3C + +

KHD Series1 globe Enclosed Reflectors globe Refractor Supply w/reflecKER40 KEP40 Wire C only KR tor T3B T3B T3B T3B T3B 60 T3B T3B T3B T3B T3B 60 T3B T3B T3B T3B T3B 75 T3B T3B T3B T3B T3B 90 T3B T3B T3B T3B T3B 75 T3B T3B T3B T3B T3B 75 T3B T3B T3B T3B T3B 90 T3B T3B T3B T3B T3B 90 T3B T3B T3B T3B T3B 90 T3B T3B T3B T3B T3B 90 T3B T3B T3B T3B T3B 75 T3B T3B T3B T3B T3B 90 T3A T3A T3A T3A 110

CLASS I DIVISIoN 2

KHC Series accepts 5 1/2 threaded optics. KHD Series accepts 7 3/4 optics. Luminaires rated for Group G (<= 165C), T3B are also suitable for Class III applications; Luminaires rated for E & F <= 200C (T3). Consult factory for elevated ambient information.

KHE Series Thermal Performance Data


Description Class I Division 2 groups A,B,C, D/Zone 2 groups IIC,IIB,IIA Class I Zone 2 AEx nAR,IIB,IIA Restricted Breathing Lamp Ambient globe globe w/Re- Refractor Enclosed Reflectors globe globe w/ Enclosed Reflectors Supply Type Watts KER40 KEP40 KER40 KEP40 C only flector Reflector Wire C KZRg 12 only HPS 200 40 T2 T2 T2 T2A T2A T4 T4 T4 T4 90 HPS 250 40 325C 325C 325C T2A T2A T4 T4 T4 T4 90 HPS 400 40 350C 350C 350C 350C 350C T3 T3 T3 T3 90 MH 250 40 300C 300C 300C 300C 300C T4 T4 T4 T4 90 MH 400 40 325C 325C 325C T2A T2A T3 T3 T3 T3 90 MHP 250 40 T2 T2 T2 T2 T2 T3 T3 T3 T3 90 MHP 320 40 T2A T2A T2A T2A T2A T3 T3 T3 T3 90 MHP 350 40 T2A T2A T2A T2A T2A T3 T3 T3 T3 90 MHP 400 40 T2A T2A T2A T2A T2A T3 T3 T3 T3 90 MV 400 40 350C 350C 350C 350C 350C T3 T3 T3 T3 90
+ Consult factory for elevated ambient information.

KHE Series Thermal Performance Data1


Description Class II Division 1 & 2 groups E,F,g & Class III Lamp globe Enlcosed Reflectors Ambient globe Refractor w/ReflecType Watts KEP40 C only KZRg 12 KER40 tor HPS 200 40 T3C T3C T3C T3C T3C HPS 250 40 T3A T3A T3C T3C T3C HPS 400 40 T3C T3C T3C MH 250 40 T3A T3A T3C T3C T3C MH 400 40 T3C T3C T3C MHP 250 40 T3A T3A T3C T3C T3C MHP 320 40 T3A T3A T3C T3C T3C MHP 350 40 T3A T3A T3C T3C T3C MHP 400 40 T3A T3A T3C T3C T3C MV 400 40 T3C T3C T3C
1 +

globe only 325C 350C 325C 325C T2 T2 T2

globe w/Reflector 325C 350C 325C 325C T2 T2 T2

Simultaneous Presence Enclosed Reflectors Refractor Supply KEP40 Wire C KZRg 12 KER40 325C 350C T1 325C T2 325C T2 T2 T2 T1 T2 T2 T1 325C T2 325C T2 T2 T2 T1 T2 T2 T1 325C T2 325C T2 T2 T2 T1 90 90 90 90 90 90 90 90 90 90

Table shows lamp temperature inside dust covered optic - see Class II table for Groups E, F, G and Class III data. Consult factory for elevated ambient information.

115

kEmLUx iii kh sEriEs


EncLosED/gAskEtED

Dimensions
1.7" (43) 11.88" DIA. (302) 5.69" (144) 13.89" (353) 12.88" (327) 14.9" (379) 2" 8.35" (51) (212) 8.96" (228) 11.88" DIA (302) 5.78" 5" (146) (127) 2" (51) 5.78" (146) 5" (127) 1.41" (36) 10.97" (279) 16.91" (430)

Pendant Mount

11.88" DIA. (302)

Cone Mount
13.67" (347) 11.35" DIA 6.89" (288) 6.38" (162) (175) 13.45" (342) 10.1" (257)

11.88" (302)

Ceiling Mount

11.88" (302)

Stanchion (25) Mount

Wall Bracket Mount


18.62" 11.56" (473) (294) 3.41" (87) 11.88" (302)

13.58" (345)

6.38" (162)

2.03" (52)

8.33" (212)

24.71" (628) 19.33" (491) 16.37" (416) 10.98" (279)

Stanchion (0) Mount


13.58" (345) 6.38" (162)

1.25" 21.35" (32) (542) 23" (584) 12.12" (308)

CLASS I DIVISIoN 2

KHE with KEP40 optic


7.56" DIA (192)

KHE Ballast Housing 12" Spun Top Refractor optics

19.65" (499) 11.31" (287)

KHE Fixture
13.58" (345) 6.38" 11.88" DIA (162) (302) 8.35" (212) 20" 1.25" (508) (32) 19.59" (498) 7.56 DIA" (192) 9.65" DIA (245) 1.62" (41) 18.25" DIA (464)

13.58" (345) 6.38" (162)

11.88" (302)

KHE Ballast Housing KER40 Enclosed Reflector KERg Wire guard

11.65" (296)

12.26" (311)

7.56" (192) 8.14" (207) 6.75" (171)

12.31" (313) 8.19" (208) 8.16" DIA (207) 14.29" (363) 10.17" (258)

13.58" (345) 6.38" (162)

KHE Ballast Housing Kg40 optics globe KAg40S Wire guard

KHC Ballast Tank 5 1/2" optics globe or Refractor KAg17 globe guard
13.58" (345) 13.58" (345)

KHC Ballast Tank KZRg1550 8" Spun Refractor


11.88" DIA (302)

12.19" (310)

6.38" (162)

6.38" (162)

KHC Ballast Tank KZRg 12" Spun Refractor


17.03" (433) 11.31" (287)

12.26" (311)

7.56" (192) 8.14" (207) 16.87" (428)

5.62" (143)

12.5" 7.81" (317) (198) 8.38" (213) 7.56" DIA (192) 9.65" DIA (245)

1.62" (41)

KHC Ballast Tank Kg17 5 1/2" optics globe KPSD40 Dome Reflector

18.25" DIA (464)

KHD Ballast Tank Kg25 7 3/4" optics globe or KR25 Refractor KAg255 Wire guard

KHD Ballast Tank KER40 Enclosed Reflector KERg guard

20.5" (521) 16.37" (416)

23" DIA (584)

116

KHD with KEP40 optic

Features

kEmLUx ii kh sEriEs
EncLosED/gAskEtED

For use in corrosive, harsh, hazardous applications such as chemical, petrochemical, marine, power generation, pharmaceutical, or food processing plants. Electro-Reg ballast provides long life, high lumen maintenance metal halide light source for low operating and maintenance costs. Mogul base socket. Cover selection of rigid and flexible pendant, ceiling, wall and 25 stanchion in varying threaded NPT entries. Minimum starting temperature of -20F for MV/MH and -40F for HPS and Electro-Reg. Copper-free (<0.4%) aluminum housing, cover and guard with white Lektrocote powder polyester paint finish. Optic choices of impact-resistant glass globe, symmetrical/asymmetrical glass refractors, dome/angle FRP reflector, 19" enclosed reflector, and polycarbonate enclosed low bay. Modular design permits selection of cover, body, globe, guard and reflector for custom applications. UL 844 Standard: Class I, Division 2, Groups A, B, C, D; Class II, Div. 1 & 2, Groups E, F, G; Class III, Div. 1 & 2. UL 1598A Marine Outdoor, NEMA 4X with K-G globe; 40C ambient listed; UL 1598 Wet Location.

ordering Information Example:


Series Kemlux KH Series KH Wattage Medium Housing 50 50W HPS 70 70W HPS, MH (Pulse Start) 1 10 100W MV, HPS, MH (Pulse Start)1 15 150W HPS 17 175W MV, MH, Electro-Reg MH, Pulse Start 25 250W MV, MH Large Housing 25 250W HPS, Electro-Reg MH, PS2 40 400W MV, MH, HPS, Electro-Reg MH, Pulse Start Lamp Type Mercury Vapor (MV) C Metal Halide (MH) H High Pressure Sodium (HPS) S Electro-Reg MH (lamp included) E Pulse Start (PS) (consult factory)7 W Voltage 120V (50W HPS and Electro-Reg 1 MH) 208V (For 175/400W Electro-Reg 2 MH only) 240V (Electro-Reg) 3 277V (50W HPS only) 4 480V (not available for 50W HPS) 5 Tri-Tap (120, 277, 347V)2, 3 6 (not available Electro-Reg) Quad Tap (120, 208, 240, 277V)3 8 E 220/240V 50 Hz3 F 347V

KH
Series

17
Watts

H
Lamp

8
Volts

G
optical Assembly

P2
Mount

UP
options

CLASS I DIVISIoN 2

optical Assembly Medium Housing g Globe Reflector/Polycarbonate Refractor X (50-150W HPS)4 Medium or Large Housing Symmetrical Glass Refractor L Large Housing Asymmetrical Glass Refractor M Enclosed Reflector E Mounting 3/4 Ceiling C2 1 Ceiling C3 1 1/4 Stanchion D4 1 1/2 Stanchion D5 1 1/4 Stanchion for Electro-Reg D8 D9 1 1/2 Stanchion for Electro-Reg P2 3/4 Pendant 1 Pendant P3 3/4 Pendant for Electro-Reg P6 P7 1 Pendant for Electro-Reg W2 3/4 Wall 1 Wall W3 3/4 Wall for Electro-Reg W6 W7 1 Wall for Electro-Reg

options Fusing (X indicates voltage)5, 6 F(X) RS Hot restrike (70-150W HPS only) Unit Pack - Mounting adapter, UP ballast housing; Globe and/or Guard in same carton (medium housing only); reflector shipped separately Factory assembled - Lamp and FA globe installed onto housing; includes mounting adapter and/or guard (medium housing only); Reflector shipped separately
1 2 3 4 5 6 7 70W and 100W metal halide includes lamp. 250W MH with Tri-Tap ballast requires deeper Electro-Reg mounting adapter. Electro-Reg is not available. Consult factory for use with 150W MH U.V. Guard lamp. To specify voltage, replace X with 1-120V, 2-208V, 3-240V, 4-277V, 5-480V, F-347V. Not offered with CSA listing. Pulse Start luminaires include lamp.

Accessories - order Separately


Catalog Number K-10 K-20 K-30 K-06 K-07 K-SC6 Description Cast Guard for K-G globe Steel wire guard for K-L and K-M glass refractors. (Zinc plated) Steel wire guard for K-E enclosed reflector. (Painted) Standard dome reflector for K-G globe. (FRP) 30 angle reflector for K-G globe. (FRP) 6 safety chain (large housing only - order separately). Weight lbs. (kg) 1 (0.5) 2 (0.9) 1 (0.5) 1 (0.5) 1 (0.5)

117

kEmLUx ii kh sEriEs
EncLosED/gAskEtED

Dimensions
Medium Housing
globe (K-g), guard (K-10), Dome (K-06) globe (K-g), Angle Dome ( K-07)

B C A
A 16 3/8 416 mm B 4 3/4 121 mm

B D
D 14 1/2 368 mm

C A
A 11 1/4 286 mm B 4 3/4 121 mm

C 5 5/8 143 mm

C 10 1/4 260 mm

D 15 381 mm

glass Refractor (k-L)

Reflector/Polycarbonate Refractor (K-X)

CLASS I DIVISIoN 2

C A
A 12 1/4 311 mm B 4 3/4 121 mm

D
A

C 13 5/16 338 mm

D 18 7/16 468 mm

A 16 406 mm

B 4 3/4 121 mm

C 11 1/2 292 mm

D 16 1/4 413 mm

Large Housing
Enclosed Reflector (K-E), guard (K-30) Refractor (K-L, K-M), guard (K-20)

B C A
A 19 483 mm B 6 1/16 154 mm

E
A
D 3 1/2 89 mm E 22 1/4 565 mm A 13 1/4 337 mm B 6 1/16 154 mm C 5 3/4 146 mm

B C E D
D 7 9/16 192 mm E 19 3/4 502 mm

C 12 5/8 321 mm

Mounting Adapters
A B
Top View

J D A
KS-B2

A
KS-P2, KS-P3

A
F 17 1/8 435 mm

g F
H 16 1/2 419 mm

I A
KS-W 2

K L
K 5 5/8 143 mm L 45 -

H
J 5 127 mm

KS-D4, KS- D5

A 12 1/4 311 mm

B 10 254 mm

C 7 1/16 179 mm

D 7/8 22 mm

E 2 3/16 56 mm

g 3 1/2 89 mm

I 4 7/16 113 mm

Electro-Reg/Ceiling Mounting Adapters


A B
Top View

F A E
KS-W6, KS-W7

H A D
KS-D8, KS-D9

A C
KS-B6

KS-C2, KS-C3, KS-P6, KS-P7

118

A 13 1/2 343 mm

B 10 254 mm

C 2 1/4 57 mm

D 18 1/4 464 mm

E 17 5/8 448 mm

F 4 7/8 124 mm

g 4 3/4 121 mm

H 5 15/16 151 mm

I 3 9/16 90 mm

kEmLUx ii kh sEriEs
EncLosED/gAskEtED

Components
The following mounting adapters are available for the KH Series. They can be ordered separately or refer to Catalog Logic for complete fixture.
Catalog Number KH-P2 KH-P3 KH-C2 KH-C3 KH-D4 KH-D5 KH-W2 KH-W3 KH-B2 KH-P61, 2 KH-P71, 2 KH-D82 KH-D92 KH-W62 KH-W72 Description Pendant Pendant Ceiling (Also for Electro-Reg) Ceiling (Also for Electro-Reg) 25 Stanchion 25 Stanchion Wall Wall Balancing Pendant Pendant/Electro-Reg Pendant/Electro-Reg 25 Stanchion/Electro-Reg 25 Stanchion/Electro-Reg Wall/Electro-Reg Wall/Electro-Reg Hubs Size 3/4 1 3/4 1 1 1/4 1 1/2 3/4 1 3/4 3/4 1 1 1/4 1 1/2 3/4 1 Qty. 1 1 4 4 1 1 4 4 1 1 1 1 1 1 4 Plugs Qty. 3 3 3 3 3 Weight lbs. (kg) 1.5 (0.7) 1.5 (0.7) 2.0 (0.9) 2.0 (0.9) 4.0 (1.8) 4.0 (1.8) 4.0 (1.8) 4.0 (1.8) 2.0 (0.9) 4.5 (2.0) 4.5 (2.0) 4.5 (2.0) 4.5 (2.0) 4.5 (2.0) 4.5 (2.0)

ordering Information: KH Mounting Adapters

CLASS I DIVISIoN 2

ordering Information: KS 50-400W Ballast Housing


Catalog Number Wattage 50W 70W 100W 150W Voltage 120 277 120/208/240/277 480 120/208/240/277 480 120/208/240/277 480 120/208/240/277 175W 480 120/208/240/277 250W 480 120/208/240/277 400W 480
1 2 3 4

High Pressure Sodium KH50S1 KH50S4 KH70S8 KH70S5 KH10S8 KH10S5 KH15S8 KH15S5 KH25S8 KH25S5 KH40S8 KH40S5

Mercury Vapor KH10C8 KH10C5 KH17C8 KH17C5 KH25C8 KH25C5 KH40C8 KH40C5

Metal Halide KH70H8 KH70H5 KH10H8 KH10H5 KH17H8 KH17EX3 KH17H5 KH17E5 KH25H8 KH25EX3, 4 KH25H5 KH25E5 KH40H8 KH40EX4 KH40H5 KH40E5

Same adapter as ceiling mount except one drilled and tapped entry on top and blank entries on sides. 250W MH with Tri-Tap ballast requires the deeper Electro-Reg mounting adapter. For Electro-Reg, replace X with 1 = 120V; 2 = 208V; 3 = 240V; 4 = 277V; 5 = 480V; F = 347V for line voltage. Example: KS17E1. Not available in 208V.

ordering Information: optical Assemblies


Catalog Number K-g K-E K-L K-M K-X Description Prismatic, heat resistant glass globe (medium housing only) 19 enclosed reflector Symmetrical (Type V) glass refractor Asymmetrical (Type II) glass refractor Reflector/Polycarbonate Refractor (medium housing only) Weight lbs. (kg) 2 (0.9) 7 (3.2) 13 (5.9) 13 (5.9) -

119

kEmLUx ii kh sEriEs
EncLosED/gAskEtED

Temperature Ratings
Class I, Division 2, class II, Division 1 & 2, Class III, Division 1 & 2 K-E/K-30 Enclosed Reflector/guard Class I, Division 2 Wattage 250W HPS 400W HPS 400W MH (INCL. E-REG) 400W MV Class II, Division 2, group g K-X Polycarbonate optic Class II, Division 2 group g Wattage 50W HPS 70W HPS 100W HPS 150W HPS 150W MH (UV guard lamp) Temp Rating C 85 85 85 85 85 T-Code T6 T6 T6 T6 T6 Maximum Ambient C 40 40 40 40 40 Temp Rating C 280 3501 300 300 T-Code T2A 1 T2 T2 Class II, Div. 1 & 2 - Class III, Div. 1 & 2 groups E, F, G E, F, G E, F, G E, F, G Temp Rating C 160 160 160 160 T-Code T3C T3C T3C T3C Maximum Ambient C 40 40 40 40

1 No T-Rating Code exists for 325C or 350C T-Ratings.

CLASS I DIVISIoN 2

Class I, Division 2, Class II, Division 1 & 2, Class III, Division 1 & 2 K-g/K-10/K-06/K-07 glass globe and guard including Angle and Dome Class I, Division 2 Wattage 50W 70W 100W 150W 70W 100W 175W (incl. Electro-Reg) 250W 1 250W 2 100W 175W 250W
1 Ceiling, pendant, wall bracket mounting. 2 Davit mount only. 3 Actual T-Rating range does not exceed 400C.

Class II, Div. 1 & 2 - Class III, Div. 1 & 2 Temp Rating C 135 135 135 160 120 160 200 160 180 180 T-Code T4 T4 T4 T3C T4A T3C T3 (K-06) T3C (K-07) T3A T3A

Maximum Ambient C 40 40 40 40 40 40 40 40 40 40 40 40

Temp Rating C 165 165 215 260 180 200 260 300 4003 300 300 450

T-Code groups HIGH PRESSURE SODIUM T3B E, F, G T3B E, F, G T2D E, F, G T2B E, F, G METAL HALIDE T3A E, F, G T3 E, F, G E, F (K-06) T2B E, F, G (K-07) T2 T13 MERCURY VAPOR T2 E, F T2 E, F T1

Class I, Division 2, Class II, Division 1 & 2, Class III, Division 1 & 2 K-L/K-20 glass Refractor and guard, K-M/K-20 glass Refractor and guard Class I, Division 2 Class II, Div. 1 & 2 - Class III, Div. 1 & 2 Wattage 50W 70W 100W 150W 250W 400W 70W 100W 175W 250W (incl. Electro-Reg) 400W (incl. Electro-Reg) 100W 175W 250W 400W Temp Rating C 180 180 200 230 280 3501 165 200 260 300 300 230 260 280 3251 T-Code groups HIGH PRESSURE SODIUM T3A E, F, G T3A E, F, G T3 E, F, G T2C E, F, G T2A E, F, G 1 E, F, G METAL HALIDE T3B E, F, G T3 E, F, G T2B E, F, G T2 E, F, G T2 E, F, G MERCURY VAPOR T2C E, F, G T2B E, F, G T2A E, F, G 1 E, F Temp Rating C 160 160 160 160 160 160 120 160 160 160 180 135 135 135 180 T-Code T3C T3C T3C T3C T3C T3C T4A T3C T3C T3C T3A T4 T4 T4 T3A

Maximum Ambient C 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40

120

1No T-Rating Code exists for 325C or 350C T-Ratings.

Features

hLmb mEDiUm bAsE


EncLosED/gAskEtED

Process lighting for use in manufacturing, corrosive, chemical, petrochemical, and marine facilities. Enclosed and gasketed housing and lamp. Compact design for low profile mounting. Houses medium base HID or twin tube fluorescent lamps Ballast housing, cover and globe guard Copper-free (<0.4%) aluminum with tan baked powder polyester electrostatically applied finish. External hardware Stainless steel. Refractor guard Steel with corrosion resistant finish. Reflector corrosion resistant polyester reinforced fiberglass. Fluorescent models furnished with lamps. UL844 Standard: Class I, Div. 2, Groups A, B, C, D; Class II, Div. 1/2, Groups E, F, G; Class III. UL1598A Marine Outdoor; NEMA 3, 4X. UL1598 Wet Location.

ordering Information Example:

HLMB
Series

L
Lamp Type

10
Watts

1
Volts

G
optic

A2
Mount

CLASS I DIVISIoN 2

Series HLMB Lamp Type F L H K Wattage 13 26 39 50 70 75 10 15

HLMB Medium Base Fluorescent High Pressure Sodium Metal Halide MV Mercury Vapor (1) 13W PL Lamp (2) 13W PL Lamp (3) 13W PL Lamp 50W HPS/MH/MV 70W HPS/MH 75W MV 100W HPS/MH/MV 150W HPS

Voltage Quad Tap - 120, 208, 240, 277V 0 60 Hz (50, 70W HPS/MH) 1 120V 60 Hz (HPS/MV/Fluorescent) 4 277V 60 Hz (13, 26W Fluorescent/MV) 5 480V (100W MV only) optic Fluted Glass Globe g Globe and Guard gg R5 Glass Refractor Type V R5g Glass Refractor and Guard

Mounting A2 A3 X2 X3 B2 B3 D4 D5 options SU103

3/4 Pendant 1 Pendant 3/4 Ceiling 1 Ceiling 3/4 Bracket 1 Bracket 1 1/4 Stanchion 1 1/2 Stanchion Assembled with lamp

Accessories - order Separately


Catalog Number HLMBg HLMBAg HLVMRWg8 HLVZRg1550 HLVMPSD17 HLVMPA17 Description Fluted glass globe Cast aluminum guard for globe units Wire guard for glass refractor units Glass Refractor, Type V Standard dome reflector (polyester reinforced fiberglass) 30 Angle reflector (polyester reinforced fiberglass)

121

hLmb mEDiUm bAsE


EncLosED/gAstkEtED

Dimensions
Ceiling Mount
A D C E G F 5/16" (8 mm) Diameter Mounting Holes A

Ceiling Mount Hub


B C

A 10 254 mm

B 8 5/32 207 mm

C 13/16 21 mm

D 1 11/16 43 mm

E 2 15/16 75 mm

F 8 9/16 217 mm

g 13 3/8 340 mm

A 9 11/16 246 mm

B 4 5/8 117 mm

C 4 9/16 116 mm

Wall Mount
B A D E C G

Wall Mount Hub


D C B A 5/16" (8 mm) Diameter Mounting Holes

CLASS I DIVISIoN 2

A 5 5/16 135 mm

B 9 15/16 252 mm

C 1 1/16 27 mm

D 1 15/16 49 mm

E 2 15/16 75 mm

F 7 3/8 187 mm

g 14 7/8 378 mm

A 4 9/16 116 mm

B 2 9/32 58 mm

C 4 5/16 110 mm

D 2 5/32 55 mm

Pendant/Stanchion Mount
E F A C J D K
S tanchion Mount Pendant/ Mount

H I L

A 2 1/8 54 mm

B 2 1/4 57 mm

C 25 635 mm

D 7 3/8 187 mm

E 9 5/16 237 mm

F 10 254 mm

g 16 7/8 429 mm

H 1 9/16 40 mm

I 15/16 24 mm

J 2 15/16 75 mm

K 5 1/2 140 mm

L 11 1/4 286 mm

Component Parts
HLMB Ballast Tank
Catalog Number HLMBL501 HLMBL701 HLMBL101 HLMBL151 HLMBH500 HLMBH700 HLMBK501 HLMBK751 HLMBK101 HLMBF131 HLMBF261 HLMBF391 Wattage HPS 50 70 100 150 MH 50 70 MV 50 75 100 FL 13 26 39 Voltage 60 Hz 120 120 120 120 Quad-Tap Quad-Tap 120 120 120 120 120 120
Note Catalog numbers shown are 120V (except Metal Halide) Consult Catalog Logic number and change sixth character to indicate other available types.

HLMB Mounting Adapters


Pendant HLMBA-2 HLMBA-3 Catalog Number Ceiling Wall HLMBX-2 HLMBB-2 HLMBX-3 HLMBB-3 Stanchion HLMBD-4 HLMDB-5 HUB Size 3/4 1 1 1/4 1 1/2

122

hLmb mEDiUm bAsE


EncLosED/gAskEtED

Temperature Codes
Twin Tube Fluorescent Hazardous Location Data
Lamp Quantity Watts/Lamp Voltage Rated Ambient C Lamp Temperature With globe, or globe & Reflector or 8 glass Refractor UL/NEC Temp. I.D. CSA/C.E.C. Temp. I.D. 165C(T3B) 165C(T3B) 180C(T3A) 160C(T3C) 160C(T3C) 135C(T4) 135C(T4) 135C(T4) 135C(T4) 135C(T4) Yes Yes Yes Yes Yes 180C(T3A) 180C(T3A) 200C(T3) 160C(T3C) 160C(T3C) 135C(T4) 135C(T4) 135C(T4) 135C(T4) 135C(T4)

1 2 3 1 2 1 2 3 1 2 1 2 3 1 2

13 13 13 13 13 13 13 13 13 13 13 13 13 13 13

Class I, Div. 2, groups A, B, C, D 120V 40 120V 40 120V 25 277V 40 277V 40 Class II, Division 1 & 2 E, F, g 120V 40 120V 40 120V 25 277V 40 277V 40 Class III, Division 1 & 2 120V 40 120V 40 120V 25 277V 40 277V 40

CLASS I DIVISIoN 2

Yes Yes Yes Yes Yes

Class I, Division 2, groups A, B, C, D HLMB Hazardous Location Application Data


Lamp Wattage Type 50 50 50 50 50 70 70 75 100 100 150 HPS HPS HPS MH MV HPS MH MV HPS MV HPS Rated Ambient C 40 55 65 40 40 40 40 40 40 40 40 Class I, Division 2, groups A, B, C, D1 Without With Reflector C With Reflector2 C Refractor C T2D (215) T2D (215) T2D (215) T2C (230) T2C (230) T2C (230) T2C (230) T2C (230) T2C (230) T2B (260) T2B (260) T2B (260) T2B (260) T2B (260) T2B (260) T2B (260) T2B (260) T2B (260) T1 (325) T1 (325) T1 (325) T1 (325) T1 (325) T1 (325) T2A (280) T2A (280) T2A (280) T1 (450) T1 (450) T1 (450) T1 (325) T1 (325) T1 (325) UL 1598A Listed Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Supply Wire Suitable for C 75 90 90 90 75 90 90 110 110

Class II, Division 1 and 2, groups E, F, g; Class III, Division 1 and 2 HLMB Hazardous Application Data
Lamp Wattage Type 50 50 50 50 50 70 70 75 100 100 150
1 2 3 4 5

Rated Ambient C 40 55 65 40 40 40 40 40 40 40 40

HPS HPS HPS MH MV HPS MH MV HPS MV HPS

Class II, Division 1 and 2, groups E, F, g4, 5 Without With With Reflector C Reflector C Refractor C T4A (120) T4 (135) T4A (120) T4 (135) T3C (160) T4 (135) T3C (160) T3C (160) T3C (160) T3C (160) T3C (160) T3C (160) T4A (120) T4A (120) T4A (120) T3C (160) T3C (160) T3C (160) T3C (160) T3C (160) T3C (160) T3C (160) T3C (160) T3C (160) T3A (180) T3 (200) T3C (160)

Class III, Division 1 and 2 Without With With Reflector Reflector3 Refractor Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No No Yes

Supply Wire Suitable for C 75 90 90 90 75 90 90 110 110

The suitability of these fixtures for Class I, Div. 2 locations must be determined for each application based on NEC Article 501-9(b) 2. Based on luminaire with globe and guard only. Includes both standard dome and angle reflectors. Guard required for Class II, Division 1 and Class III, Division 1 applications. 150 Watt HPS Groups E, F only with or without reflector, and Groups E, F, G with refractor.

123

mArinEr fLooDLight
stAinLEss stEEL fLooD

Features

For use in corrosive, hosedown, marine, shipboard and hazardous environments. Integrally ballasted luminaire. SFMM series for marine applications. SFM2 for hazardous and marine applications. Restricted Breathing RB option for lower T-Ratings. Elevated ambient EA option capability up to 65C. Quick release lens latches for ease of entry. No screws. Luminaire, lens frame, lens latches 16 gauge 316SS. Mounting yoke, safety lens door chains, cord grip (SFMM), conduit hubs (SFM2) SS316. Mounting accessories Hot dipped galvanized steel. SFMM and SFM2 Listings. UL1598 and 1598A Marine Outdoor. NEMA 4X; IP66/67. Type Approval American Bureau of Shipping (ABS). SFM2 Listings. UL844 Standard: Class I, Div. 2 Groups A, B, C, D; Class I, Zone 2 Groups IIC, IIB, IIC. ExnR, AxnR Restricted Breathing.

ordering Information

SFM2
Series

40
Watts

H
Lamp

8
Volts

options F(X) RS QS PCR(X) EA RB

EA
options

RB
options

CLASS I DIVISIoN 2

Series SFMM SFM2 Wattage 15 17 25 40

Stainless Flood Marine Stainless Flood - Class I, Division 2 150W HPS, PS 175W MV, MH 250W HPS, MH, MV, PS5 400W HPS, MH, MV, PS

Lamp Type Metal Halide H High Pressure Sodium S Mercury Vapor C Pulse Start (PS) Metal Halide W (lamp included) Voltage 480V5 5 6 Tri-Tap (120, 277, 347V) Quad Tap (120, 208, 240, 277V) 8 220/240V 50 Hz E 220V 60Hz (250, 400W MH only) P

1 2 3 4 5

To denote voltage, replace X with 1 - 120V; 2 - 208V; 3 - 240V; 4 - 277V; 5 - 480V; 6 - 347V. Not UL 1598A Marine Listed or CSA listed for hazardous locations. CSA certification applilcable to Tri-Tap ballast only. Available in SFMM only. Not suitable for hazardous locations. 250W Pulse Start not available in 480V or Tri-Tap.

Fusing (specify voltage)1, 2, 3 Hot Re-Strike (150W HPS) Quartz Standby4 Photocontrol1, 2, 3, 4 Elevated Ambient (40C, 55C, 65C) capabilities. See chart for applicable wattages Restricted Breathing Housing allowing lower T-Ratings for SFM2 and SFMH2 Series only. Fixture provided with test port entry on side

ordering Information
Series SFMH2 Entries C1 C2 C3 C4

SFMH2
Series

C3
Entries

UH

Requires Remote Ballast Assembly on following page

Stainless Steel Remote Head, ClassI, Division 2 Marine 3/4 Conduit Hub 20mm Conduit Hub 3/4 Conduit Hub Restricted Breathing 20mm Conduit Hub Restricted Breathing

Lamp Lamp Type Universal Head, 350W Pulse Start, 400W HPS, MH, UH Electro-Reg, Pulse Start, 1000W HPS2 HH 1000W MH

Dimensions
18.3" (465mm) 8.6" (220mm)

19.7" (500mm) 25.2" (640mm)

11.0" (279.4mm) 4.2" (106.3mm)

10.16"(258.06mm) Center Hole 0.88" (22.2mm)

2 Holes 0.56" (14.3mm) 3.1" (79.5mm)

10.8" (274.3mm) 2.0" (50.8mm)

1.5" (39.75mm) 20.2" (513mm)

2.0" (50.8mm)

124

ENTRY SFMM: 1/2" CoRD gRIP SFM2: 3/4" CoNDUIT HUB

Features

mArinEr fLooDLight
rEmotE bALLAstED

For use in corrosive, hosedown, marine, shipboard and hazardous environments. SFMH2 luminaire available in two styles; UH for asymmetric and HH (1000W MH only) for symmetric distribution. Restricted Breathing option for lower T-Ratings. Elevated ambient capability up to 65C. Luminaire and ballast housing, lens frame, quick release lens latches 16 gauge 316SS. Mounting yoke, safety lens door chains, cord grip, conduit hubs 316SS. Mounting accessories Hot dipped galvanized steel SFMH2 and SSRB Listings. UL844, CSA 22.2 No. 137-M1981: Class I, Div. 2 Groups A, B, C, D; Class I, Zone 2 Groups IIC, IIB, IIC. ExnR, AxnR Restricted Breathing. UL1598A Marine Outdoor. UL 1598 Wet Location. Type Approval American Bureau of Shipping (ABS). NEMA 4X, IP66/67.

ordering Information
SSRB
Series Series SSRB Entries C1 C2 Wattage 0350 0400 1000 Lamp Type E H S W Voltage 1 2 3 4 5 6 8 E F P options1, 2 F(X)
1 2

SFMM/SFM2 Integral Ballast Ambient Suitabilities & T-Ratings


Wattage and Lamp Type T-Ratings & Ambient Temperatures 40C 50C 65C Class I Class I Class I Class I Class I Class I Div. 2 / Zone 2 Div. 2 Zone 2 Div. 2 Zone 2 Zone 2 ExnR / Zone ExnR / Zone ExnR AExnR 2 AExnR 2 AExnR T1 T4 T1 T3 T1 T3 T1 T4 T1 T3 T1 T3 T1 T3 T1 T1 T1 T3 T2A/T2 T4 T2 T4 T2 T3 T1 T3 T1 T3 T1 T3 T1 T4 T1 T4 T1 T3 T1 T3 T1 T3 T1 T3

C1
Entries

1000
Watts

H
Lamp

8
Volts

CLASS I DIVISIoN 2

Stainless Steel Remote Box, Class I, Division 2 Marine, Class I, Division 2/Zone 2 Marine 3/4 Conduit Hub 20mm Conduit Hub 350W Pulse Start only 400W HPS, MH, PS, E-Reg 1000W HPS, MH Electro-Reg Metal Halide (400W only) Metal Halide High Pressure Sodium Pulse Start (PS) 350/400W 120V Electro-Reg only 208V Electro-Reg only 240V Electro-Reg only 277V Electro-Reg only 480V Tri-Tap (120/277/347V) (not available in with 400W PS) Quad Tap (120, 208, 240, 277V) 220/240V 50 Hz 347V Electro-Reg only 220V 60Hz (400/1000W MH only) Fusing (specify voltage)

150W PS 175W MH 250W MH, PS 400W MH, PS 150W HPS 250W HPS 400W HPS 175W MV 250W MV 400W MV
Note

For standard SFM2 (less suffix EA), apply T-Ratings from 40C column above.

SFMM/SFM2 Integral Ballast Supply Wire Ratings (Suffix EA)


Wattage and Lamp Type 175W MH 250W MH, PS 400W MH, PS 150W HPS 250W HPS 400W HPS 175W MV 250W MV 400W MV 40C 90C 110C 110C 90C 90C 110C 90C 90C 110C Ambient Temperature 55C 110C 110C 90C 110C 110C 110C
20.0" (508mm) 15.25" (387mm) 0.62" diameter (16mm)

Not CSA or NEMA certified with F option. To denote voltage, replace X with 1 - 120V; 2 - 208V; 3 - 240V; 4 - 277V; 5 - 480V; 6 - 347V.

Accessories - order Separately


Catalog Number 4024C-M38 4040-M38 4090-M38 PTL11, 2 PTL81, 2 PTL51, 2 PSC1, 2 SFM-LR
1 2

65C 110C 110C 110C

Description Hot-Dipped Galvanized Steel Slipfitter for 2 pipe (2 3/8 OD tenon) - hardware included Hot-Dipped Galvanized Steel Wall/Pole Bracket - hardware included Hot-Dipped Galvanized Cross Arm Fitting for horizontal trunnion - hardware included Photocontrol - Twist-Lock Cell 120V Photocontrol - Twist-Lock Cell 120 - 277V Photocontrol - Twist-Lock Cell 480V Photocontrol Shorting Cap - Twist-Lock Mount (completes circuit) 1/8 diameter, 3 steel safety cable, Hot-Dipped Galvanized

9.25" (235mm) 11.25" (286mm)

Supply wire rating is 90

Dimensions

6.63" (168mm)

6.0" (152mm)

Not UL 1598A Marine Outdoor listed. Available in SFMM only. Not suitable for hazardous locations.
1.5" (38mm)

125

hAZArDoUs strobEs
Es AnD gsh sEriEs

Features

ES Series

For use as a warning device in hazardous or harsh locations where hearing is impaired due to high ambient noise. Solid State circuitry for reliable operation provides 85 flashes per minute. Factory sealed with quick-connect contact block. Ambient Temperature range from -40C to +55C. Housing, guard die cast copper-free (<0.4%) aluminum with electrostatically applied baked polyester finish. Globe fluted, clear, heat and impact resistant outer glass with colored inner polycarbonate lens. UL 844 Standard: Class I, Div. 1/2, Groups C, D (T6); Class II, Div. 1/2, Groups E, F, G (T4); Class III, Div. 1/2. UL 1598A Marine Outdoor; NEMA 3, 4X, 7CD, 9EFG. UL 1638 visual signaling appliances.

ES Series - Class I, Division 1

CLASS I DIVISIoN 2

Pendant Mount ESXX-120A-A2 ESXX-120A-A3 ESXX-1274-A2 ESXX-1274-A3


Note Note

Catalog Number Ceiling Mount Bracket (Wall) Mount ESXX-120A-X2 ESXX-120A-B2 ESXX-120A-X3 ESXX-120A-B3 ESXX-1274-X2 ESXX-1274-B2 ESXX-1274-X3 ESXX-1274-B3

Stanchion Mount ESXX-120A-D4 ESXX-120A-D5 ESXX-1274-D4 ESXX-1274-D5

Hub Size 3/4 1 3/4 1

Voltage 120V AC 120V AC 12-74V DC 12-74V DC

Flash/Minute 90 90 90 90

All items are available with guard, add -G to the end of the catalog number. Lens color must be specified. Substitute for second X in catalog number as follows: R - Red; B- Blue; A - Amber; C - Clear; G - Green. Example: ESXR-120A-A2. 240V AC units are available. To specify, substitute for 5th through 8th digits as follows: i.e.: ESXX-240A-A2.

Features
gSH Series
For use as a warning light in hazardous and harsh locations where high ambient noise levels are prevalent. Reliable solid state circuitry providing 60 flashes per minute. Choice of four globe colors and two voltages. Globe may be mounted in up or down position. Compact aluminum housing with polycarbonate lens. UL844 Standard: Class I, Div. 2, Groups C, D (T4A). NEMA 3.

gSH Series - Class I, Division 2


Catalog Number gSH-2-X-A1 gSH-2-X-D1 gSH-2-X-D2
Note

Mounting 1 pipe 1 pipe 1 pipe

Dimensions W x H 4 1/2 x 8 4 1/2 x 8 4 1/2 x 8

Voltage 120V AC 12V DC 24V DC

Amps .28 .7 .35

Candela 400 400 400

Flash/Minute 60 60 60

Lamp Type ST77C ST77C ST77C

Ship Weight (lbs) 4 4 4

Lens color must be specified. Substitute for X in catalog number as follow: R - Red; B - Blue; A - Amber; C - Clear.

126

Features

LightwAtt hAZArDoUs

EncLosED/gAskEtED

For use as process lighting in harsh and hazardous environments where the presence of obstructions due to machinery, and process piping may cause shadows. Ideal for chemical, petrochemical, power plants and food processing. Excellent vertical and horizontal footcandle distribution with 25% uplight. Spacing to mounting height ration of up to 2.3 : 1. Luminaires shipped with lamps installed for ease of installation. Ceiling thru-wire/pendant, wall and stanchion mounting choices. Choice of mogul base HPS, MH, and E-Reg, as well as triple tube fluorescent. Housing Copper-free (<0.4%) aluminum. Lens high performance acrylic, or polycarbonate. External hardware HubbellGard UL844 Standard: Class I, Div. 2, Groups A, B, C, D; Zone 2, Groups IIC, IIB, IIA UL1598 Wet Location. IP65 listed (for outdoor use). Optional NSF listed for food processing (-FP). For dimensions see Industrial Lightwatt on page 53.

ordering Information Example:


Series Lightwatt Division 2 LW2 Mounting Ceiling thru-wire / pendant C B Pipe wall bracket S Stanchion / Davit Wattage 42W compact triple tube 42 fluorescent 2 x 32W compact triple tube 64 fluorescent 70W HPS, MH 70 2 x 42W compact triple tube 84 fluorescent 100W HPS, MH 10 150W HPS, MH (UV Protected) 15 175W Electro-Reg MH, 17 MH (CWA)1

LW2
Series

C
Mount

84
Watts

F
Source

4
Volts

A
Refractor

LTP
options

Source H S E F Voltage 1 3 4 5 6 8 E F P

Metal Halide High Pressure Sodium Electro-Reg Fluorescent 120V Electro-Reg only 240V Electro-Reg only 277V Electro-Reg only 480V Electro-Reg only Tri-Tap (120, 277, 347V) Quad Tap (120, 208, 240, 277V) 220/240V 50Hz (HPS and MH only) 347V Electro-Reg only 220V 60Hz (available for limited light sources, consult factory.)

options F(X) LTP LL RS FP

Fusing (specify voltage)2 Tamper resistant screws Less lamp3 Hot restrike (HPS only) National Sanitation Foundation Listed

CLASS I DIVISIoN 2

1 2 3

Acrylic optics with 175W lamps may experience accelerated aging. To specify correct voltage, replace X with 1-120V; 2-208V; 3-240V; 4-277V; 5-480V; F-347V. Fixture shipped with lamps installed as standard.

Refractor Acrylic A Polycarbonate (HPS, Fluorescent) P 55C rating

Temperature Ratings (measured at ambient temperatures listed)


Wattage/Lamp Type 70W HPS 100W HPS 150W HPS 70W MH 100W MH 150W MH 175W E-reg 42W Fluorescent 64W Fluorescent 84W Fluorescent
Note Note Note

Class I, Division 2 groups A, B, C, D 40C T Rating 55C T Rating T3A T2D T2C T2B T2B T2A T3C T3A T3B T3A T2D T2 T2A T2 T3C T3A T3C T3A T3B T3A

Class I, Zone 2 groups IIC, IIB, IIA 40C T Rating 55C T Rating T3 T2 T2 T2 T2 T2 T3 T3 T3 T3 T2 T2 T2 T2 T3 T3 T3 T3 T3 T3

90C supply wire required. Class I, Division 2 T-Ratings per National Electrical Code Table 500-5(d). Class I, Zone 2 T-Ratings per National Electrical Code Table 505-10(b)(3).

Ambient Temparture Suitabilities (Acrylic optic)2


Wattage 42W 64W 84W 70W 100W 150W 175W
1 2

Accessories - order Separately


Catalog Number LW-g Description Steel wire guard

HPS ------55C 50C 40C ---

MH ------55C 50C 40C1 35C

Fluorescent 50C 45C 40C ---------

Fixture tested with U.V. Guard Lamp. Polycarbonate optic results in 55C for all HPS and Fluorescent wattages and lamp sources. When used with MH, recommended use of 150W U.V. Guard Lamp only, resulting also in 55C.

127

vAportitE v-sEriEs
EncLosED/gAskEtED

Features

For wet and dirty environments where enclosed/gasketed fixtures are needed. Cover selections include pendant, ceiling, bracket and stanchion mounting. Modular design permits selection of cover, body, globe, guard and reflector for custom applications. Threaded hubs for attachment to conduit and set screws provided in pendant covers. Two size housings for 150W and 300W max. Colored globes available. Body/Guard Copper-free (<0.4%) cast aluminum. Globe Standard and tempered glass. Clear polycarbonate for 75W max. Reflector White Poly-Pro plastic. UL1598 Damp Location. NEMA 3, 4 (when used with VXFC body and tempered globe). UL844: Class I, Division 2, Groups A, B, C, D (VXFC only).

Catalog Number VP-1511 VP-152A1 VP-3011 VP-3021 VX-1511 VX-1521 VX-3011 VX-302 VF-1511 VF-3011 VWX-1511 VWX-1521 VWX-3011 VWX-3021 VW-1511 VW-3011 VS-150 VS-300

Maximum Lamp Size 150/A-21 150/A-21 300/PS-25 300/PS-25 150/A-21 150/A-21 300/PS-25 300/PS-25 150/A-21 300/PS-25 150/A-21 150/A-21 300/PS-25 300/PS-25 150/A-21 300/PS-25 150/A-21 300/PS-25

Hub Size Pendant

Body2

Fixture Components Cover VP-1 VP-2 VP-1 VP-2 VX-1/VAP VX-2/VAP VX-1/VAP VX-2/VAP VAP VAP VW-1/VX-1 VW-1/VX-2 VW-1/VX-1 VW-1/VX-2 VW-1 VW-1 VD-4 VD-4

globe VG-15 VG-15 VG-30 VG-30 VG-15 VG-15 VG-30 VG-30 VG-15 VG-30 VG-15 VG-15 VG-30 VG-30 VG-15 VG-30 VG-15 VG-30

1 2

CSA Certified. For Class I, Division 2 and NEMA 3/4, replace: VFB-15 with VXFC-100-N34; and VFB-30 with VXFC-200-N34. Order body, cover and globe as components. See T-Rating chart.

1/2 VFB-15 3/4 VFB-15 1/2 VFB-30 3/4 VFB-30 Ceiling outlet Box 1/2 VFB-15 3/4 VFB-15 1/2 VFB-30 3/4 VFB-30 Ceilng Plate VFB-15 VFB-30 Wall Arm outlet Box 1/2 VFB-15 3/4 VFB-15 1/2 VFB-30 3/4 VFB-30 Wall Arm Mount VFB-15 VFB-30 Stanchion Mount 1 1/4 VFB-15 1 1/4 VFB-30

CLASS I DIVISIoN 2

Pendant

Ceiling outlet Box

Ceiling Plate

ordering Information: globes - V/NV/NVQ


Catalog Number Vg-15 VCgP-100 VAMgP-100 VggP-100 VRgP-100 VBgP-1001 VgP-151 Vg-30 VCgP-200
1 75W maximum.

globes 150 Watts Clear, Standard Clear, Tempered Amber, Tempered Green Ruby Blue Polycarbonate 300 Watts Clear, Standard Clear, Tempered

VFB-30 VXFC-200-N34

Wall Arm Wall Arm outlet Box Mount

Stanchion Mount

VFB-15 VXFC-100-N34 VAP Ceiling Box Adapter

128

vAportitE v-sEriEs
Dimensions
C A B
VX-1, 1/2" Box VX-2, 3/4" Box

EncLosED/gAskEtED

A B
VP-1, 1/2" Pendant Cover VP-2, 3/4" Pendant Cover

A B D C
A 4 3/4 121 mm B 2 1/2 64 mm
VW -1 Wall Arm

A 1 11/16 43 mm

B 4 3/16 106 mm

C 5 11/16 144 mm

A 2 1/8 54 mm

B 3 1/2 89 mm

C 4 7/8 124 mm

D 3 1/8 79 mm

VCg-15, VCg-30 guards

VD-4 1 1/4 Stanchion Mount

A B C

B A

CLASS I DIVISIoN 2

C
Watts A 7 5/8 150 194 mm 10 5/8 300 270 mm B 6 7/8 175 mm 9 7/8 251 mm C 4 1/4 108 mm 5 1/2 140 mm Watts A 9 3/8 150 238 mm 10 3/4 300 273 mm

B 8 5/8 219 mm 11 1/2 292 mm

C 11 279 mm 12 1/4 311 mm

Accessories - order Separately


Catalog Number VRSD-15 VRSD-30 VCg-15 VCg-30 Maximum Lamp Size Reflector1 150 300 guards 150 300 Material White Poly-Pro White Poly-Pro Cast Aluminum Cast Aluminum

1 Note Note

Not for use with VS stanchion. Angle reflector not available. Supply wire ratings - 150 series is 125C; 300 series is 150C

VXFC1 T-Ratings
Fixture Type 150 150 150 150 150 150 300 300 300
Note 1

Lamp Type A-19/60W A-19/70W A-19/100W A-21/100W A-21/150W A-21/150W A-23/200W PS-25/200W PS-25/300W

Temperature Code T2C T2D T2A T2B T2 colored globe T2 clear globe T2 T2A 350C

Suitability based on base up installation. For Class I, Division 2 and NEMA 3/4, replace: VFB-15 with VXFC-100-N34; and VFB-30 with VXFC-200-N34. Order body, cover and globe as components. See T-Rating chart.

129

kEmLUx iii ks sEriEs


EncLosED/gAskEtED

Features

For use in corrosive, wet and dirty industrial applications such as power generation, waste water and sewage treatment, pulp/paper or steel mills. Electro-Reg ballast provides long life, high lumen maintenance metal halide light source for low operating and maintenance costs. Cover selection of rigid and flexible pendant, ceiling, wall and 25 stanchion of varying threaded NPT entries. Minimum starting temp of 20F for MV/MH and 40F for HPS and Electro-Reg. Copper-free (<0.4%) aluminum housing, cover and guard with Lektrocote powder polyester paint finish provides excellent corrosion resistance from most chemicals. Color is gray. Optic choices of impact-resistant glass globe, symmetric/asymmetric glass refractors, dome/angle fiberglass reinforced polyester reflector, 19" enclosed reflector, and polycarbonate enclosed lowbay. Unit shown with optional globe guard. Modular design permits selection of cover, body, globe, guard and reflector for custom applications. UL1598 Wet Locations; NEMA 4X with KG17 globe, 55C ambient listed.

ordering Information:
Series KS Kemlux III KS Tank Type C Low Wattage Mogul Base 5" D Low Wattage Mogul Base 8" E High Wattage Mogul Base 8" Lamp Type S High Pressure Sodium H Metal Halide P Pulse Start Metal Halide M Mercury Vapor Wattage 05 50 watt (HPS) 07 70 watt (HPS, MH) 10 100 watt (HPS, MH, MV) 12 125 watt (Pulse Start MH) 15 150 watt (HPS, Pulse Start MH) 17 175 watt (MH, Pulse Start MH, MV) 20 200 watt (HPS) 25 250 watt (HPS, MH, Pulse Start MH) 32 320 watt (Pulse Start MH) 35 350 watt (Pulse Start MH) 40 400 watt (HPS, MH, Pulse Start MH, MV) Voltage (@ 60 HZ) 0 Quadri-Volt (120, 208, 240, 277V) 5 480V 6 Tri-Tap Canada (120, 277, 347V) 7 220V 8 220/240V 50 Hz Mounting Type A Pendant X Ceiling B Wall Bracket C Cone Top D Stanchion 25 S Stanchion Straight 90 N None (mount ordered separately)1
1 NN mount ordered separately. 2 Tuffskin is a registered trademark of Thomas Mfg. Corp. 3 Teflon is a registered trademark of DuPont, Inc. 4 Order guards for spin-tops & KER40 separately.

KS
Series

D
Tank

H
Lamp

40
Wattage

0
Voltage

A
Mount

2
Entry

GL
optic

G
guard

Entry (mounts available) 34" NPT (A, B, C, X) 2 3 1" NPT (A, B, C, X) 4 114" NPT (D, S) 5 112" NPT (D, S) 34" NPT 5-hub (X) 6 7 1" NPT 5-hub (X) N None (mount ordered separately)1 optics gL Globe R1 Type I Glass Refractor R3 Type III Glass Refractor (KSD only) R5 Type V Glass Refractor ER Enclosed Reflector (KSD & KSE only) EP Polycarbonate Shielded Enclosed Reflector (KSD only)7 S2 Type II 12" Spin-Top Refractor S8 Type V 8" Spin-Top Refractor (KSC & KSE only) S5 Type V 12" Spin-Top Refractor P5 Type V Plastic Spin-Top Refractor (KSC only) Fg Tuffskin Coated Globe1 Tg Teflon Coated Globe2 T1 Teflon Coated Globe Type I Glass Refractor2 T3 Teflon Coated Globe Type III Glass Refractor (KSD only)2 T5 Teflon Coated Globe Type V Glass Refractor2 T2 Teflon Coated Globe Type II 12" Spin-Top Refractor 2 T8 Teflon Coated Globe Type V 8" Spin-Top Refractor (KSC only)2 TV Teflon Coated Globe Type V 12" Spin-Top Refractor 2 guard g Globe Guard N No Guard4
5 Fusing not for Marine or Canadian installations. 6 Field connection to proper tap in case of Multitap ballasts. 7 Not for use with wall or straight (90) stanchion.

options QA Quartz Auxiliary6 BP Ballast Protector (250-400W HPS only) F1 Fusing - single 120V 60Hz5 F2 Fusing - double 208V 60Hz5 F3 Fusing - double 240V 60Hz5 F4 Fusing - single 277V 60Hz5 F5 Fusing - double 480V 60Hz5 F6 Fusing - single 347V 60Hz5 F7 Fusing - double 220V 60Hz5 F8 Fusing - double 230V 50Hz5 P1 Photo Cell 120V 6 P2 Photo Cell 208-277V (must specify voltage on order)6 P3 Photo Cell 347V6 Q1 Quick Disconnect wired at ballast to 120V8 Q2 Quick Disconnect wired at ballast to 208V8 Q3 Quick Disconnect wired at ballast to 240V8 Q4 Quick Disconnect wired at ballast to 277V8 Q5 Quick Disconnect wired at ballast to 480V8 Q6 Quick Disconnect wired at ballast to 347V8 Q7 Quick Disconnect wired at ballast to 220V8 Q8 Quick Disconnect wired at ballast to 230V8 TB Terminal Blocks AS Assembled Fixture with standard lamp AD Assembled Fixture with DAT Dual-Arc-Tube lamp (250, 400W HPS only CS Component Pack with standard lamp CP Component Pack - no lamp
8 QX = Quick Disconnect. Allows easy tank removal for maintenance. Electrician simply unplugs de-energized ballast from supply circuit.

SEALED

Accessories - order Separately


Catalog Number K-SC6 Description 6 Safety Chain (large housing only) Weight lbs. (kg) 1 (0.5)

130

Photocontrol for Standard & Hazardous Class I Division 2


Catalog Number HUB2PC120 HUB2PC2771 HUB2PC347
1

kEmLUx iii ks sEriEs


EncLosED/gAskEtED
Frequency 50/60 Hz 50/60 Hz 50/60 Hz Watts 400 400 400

Volts 120VAC 277VAC 347VAC

Marked 220-277V, suitable for 208V.NOTE Patent Pending.

Kemlux III Mounting Splice Boxes


Hub Size 3/4 1 1-1/4 1-1/2 M-20 Pendant KSA2B KSA3B Flexible Pendant KSF2B KSF3B Ceiling 4-Hub KSX2B KSX3B KSX8B Catalog Number Ceiling Wall 5-Hub KSX6B KSB2B KSX7B KSB3B KSX9B Cone Top KSC2B KSC3B 25 Stanchion KSD4B KSD5B 90 Stanchion KSS4B KSS5B

Kemlux III 50-600W Ballast Tank Assemblies


Catalog Number High Pressure Sodium Low Wattage Watts 50 70 100 150 175 200 250 320 350 400 5-1/2 KSCS05X KSCS07X KSCS10X KSCS15X 7-3/4 KSDS05X KSDS07X KSDS10X KSDS15X High Wattage 7-3/4 KSES20X KSES25X KSES40X Metal Halide Low Wattage 5-1/2 KSCH07X KSCH10X KSCH15X KSCH17X KSCH25X 7-3/4 KSDH07X KSDH10X KSDH15X KSDH17X KSDH25X High Wattage 7-3/4 KSEH40X Pulse Start Metal Halide Low Wattage 5-1/2 KSCP15X KSCP17X KSCP20X 7-3/4 KSDP15X KSDP17X KSDP20X High Wattage 7-3/4 KSEP25X KSEP32X KSEP35X KSEP40X Mercury Vapor Low Wattage 5-1/2 7-3/4 High Wattage 7-3/4 KSEM40X

KSCM10X KSDM10X KSCM17X KSDM17X KSCM25X KSDM25X

SEALED

Note Replace X with voltage: 0-Quad, 6-Tri, 5-480V.

optics

Kg17

guards

KR175 KR171

KZRg1550

KZRg2550 KZRg2520

Kg25

KR255 KR253 KR251

Kg40

KER40

KZRg4050 KZRg4020

KEP40

KSAg172

KSAg172

KRWg84

KRWg4

KAg25S3

KAg25S3

KAg40S3

KERg3

KRWg4

Wg-23

Reflectors

KPSD40 Standard Dome Fiberglass White Reflector Dia: 16


1 2 3 4

KPA40 Angle Fiberglass White Reflector Dia: 16

HRD400 Deep Aluminum White Reflector Dia: 21

HRD400ALZ Deep Aluminum Anodized Finish Reflector Dia: 21

KAgBC Bottom Closure for KAg25S/SAg40S

KSC 12 Spin Tops ship with a mogul-to-mogul extender for improved photometrics. Standard material: copper-free aluminum painted. Standard material: 316 stainless steel. Standard material: plated steel.

131

kEmLUx iii ks sEriEs


EncLosED/gAskEtED

Dimensions
Mounting Adapters
5.69" (144 mm) 13.89" (353 mm) 12.88" (327 mm) 2.0" (51 mm)
3.58" (345 mm) 3.58" 8.96" (345 mm) 6.38" (228 mm) (162 8.35"6.38" mm) (162 (212 mm) mm)

14.9" (379 mm)

2.0" (51 mm)


11.88" (302 11.88" mm) (302 mm)

11.88" dia. (302 mm)

11.88" dia. (302 mm)

11.88" dia. (302 mm)

Cone Mount
5.75" (146 mm) 5.0" (127 mm) 5.75" 1.7" (43 mm) (146 mm) 5.0" (127 mm)

Ceiling Mount
10.97" 1.41" (279 mm) (36 mm)

12.26" (311 16.91" mm) 12.26" (311 mm) (430 mm)

Stanchion (25) Mount 12.31"


7.56" (192 mm) 7.56" 18.62" (192 mm) 8.14" (473 mm) 11.56" (207 mm) 8.14" (294 mm) (207 mm)

(313 12.31" mm) (313 mm) 8.19" (208 mm) 8.19" (208 mm)

11.88" dia. (302 mm)

11.88" dia. (302 mm)

Pendant Mount

Wall Bracket Mount

KXC Housing
3.58" (345 mm) 3.58" (345 mm) 6.38" (162 mm) 6.38" (162 mm) 11.88" (302 mm) 11.88" (302 mm)

KSC Ballast Tank KSC Ballast Tank 51/2" Optics Globe or Refractor Stanchion (0) Mount 51/2" Optics Globe Globe Guard 13.58" KSAG17 or Refractor (345 mm) KSAG17 Globe Guard
13.58" (345 13.58" mm) 6.38" (345 mm) (162 mm) 6.38" (162 mm) 6.38" (162 mm)

(171 mm) 6.75" (171 mm)

3.41" (87 6.75" mm)

2.03" (52 mm)


8.16" dia. (207 8.16" dia. mm) (207 mm)

11.88" dia. (302 mm)

KSC Ballast Tank KSC Ballast Spun KZRG1550 8"Tank Refractor KZRG1550 8" Spun Refractor
13.58" (345 13.58" mm) (345 mm)

6.38" (162 mm) 6.38" (162 mm)

7.81" (198 mm) 14.29" (363 14.29" mm) (363 mm) 10.17" (258 10.17" mm) (258 mm)

12.5" (317 mm) 12.26" 8.38" 7.56" (311 12.26" mm) (213 mm) (192 mm) 7.56" (311 mm) (192 mm) 8.14" 7.56" dia. (192 mm) 9.65" dia. (245 mm) (207 mm) 8.14" (207 mm)

11.88" dia. (302 mm)

12.26" (311 mm)

12.26" (311 mm)

12.31" (313 mm) 7.56" (192 mm) 8.14" (207 mm) 7.56" (192 mm) 8.14" (207 mm) 8.19" (208 mm)

12.31" (313 mm) 8.19" (208 mm)

5.62" (143 mm) 5.62" (143 mm)

SEALED

13.58"6.75" (171 (345 mm) mm) 6.38" KSC Ballast Tank Ballast mm) KSC (162 Tank 1/2" Optics Globe " Optics Globe or Refractor 5 51/2 or Refractor

6.75" (171 mm)

8.16" dia. (207 mm)

8.16" dia. (207 mm)

KSAG17 Globe KSAG17 Globe Guard Guard

KSC Ballast Tank Ballast Tank KSC KZRG1550 8" Spun RefractorSpun Refractor KZRG1550 8"

KSC Ballast Tank KSC Ballast TankRefractor KZRG 12" Spun KZRG 12" Spun Refractor

12.19" dia. 12.19" (310 mm) dia. (310 mm)

KXD Ballast Tank KG25 7 3/4" Optics Globe or KR25 Refractor KAG25S Wire Guard

16.87" dia. 11.31" 16.87" (428 mm) dia. (287 mm) mm) (428

17. (433

KXD Housing
13.58" (345 mm) 7.81" (198 mm) 13.58" (345 mm) 6.38"13.58" (162 mm) mm) (345 6.38" (162 mm) 12.5" 6.38" (317 mm) (162 mm) 8.38" (213 mm) 12.26" 12.26" 7.56" mm) (311 mm) 7.56" (311 12.5" (192 mm) (192 mm) (317 mm) 8.14" 8.14" (207 mm) (207 mm) KXD Ballast Tank 8.38" 11.31" KG25 7 3/4" Optics Globe (213 mm) (287 mm) 7.56" dia. (192 mm) 9.65" dia. (245 mm) 6.38" (162 mm)

KSC Ballast Tank KSC 51/2" Optics Globe KG17 1.62" Ballast Tank KG17KPSD40 Dome Reflector 5 (41 mm)1/2" Optics Globe KPSD40 Dome Reflector

13.58" 6.38" (345 mm) 11.88"mm) (162 dia. (302 mm)

13.58" (345 mm)

18.25" dia. (464 mm)

KXD Ballast Tank KER40 Enclosed Reflector KERG Guard

" m) 10.17" (258 mm)

14.29" (363 mm)

7.81" (198 mm)

11.88" dia. (302 mm)

10.17" (258 mm)

5.62" (143 mm) 17.03" (433 mm)

5.62" (143 mm)

20.5" (521 mm) 16.37" (416 mm)

or KR25 Refractor KAG25S Wire Guard


7.56" dia. (192 mm) 9.65" dia. (245 mm) 12.19" dia. (310 mm)

16.87" dia. (428 mm) 1.62" (41 mm)

16.87" dia. (428 mm) 17.03" (433 mm)

KXD Ballast Tank KSC Ballast Tank 7Ballast Tank KSC KG25 3/4" Optics Globe KZRG 12" Spun RefractorSpun Refractor KZRGor KR25 Refractor 12" KAG25S Wire Guard

12.19" dia. (310 mm)

11.31" 18.25" dia. KSC Ballast Tank Ballast Tank KSC (287 mm) (464 Globe KG17 51/2" Opticsmm) 1/2" Optics Globe KG17 5

KPSD40 Dome KPSD40 Dome Reflector Reflector KXD Ballast Tank KER40 Enclosed Reflector KERG Guard

23.0" dia. (584 mm)

KXE Housing
1.7" 43 mm) 13.67" (347 mm) 11.35" dia. (288 mm) 6.89" 6.38" (175 mm) (162 mm)

1.62" (41 mm) 18.25" dia. (464 mm)

KXD Ballast Tank KPE40 Optic KXD Ballast Tank 13.58" (345 KER40 Enclosed Reflector mm) KERG Guard
13.58" (345 mm) 13.58" (345 mm) 11.88" dia. (302 mm)

20.5" (521 mm)


10.10" (257 mm)

6.38" (162 mm)

6.38" (162 mm)

6.38" (162 mm)

8.33" (212 mm)

1.25" (32 mm) 21.35" (542 mm)

16.37" (416 mm)


19.33" (491 mm) 19.65" (499 mm) 10.98" (279 mm) 11.31" (287 mm) 20.0" (508 mm)

8.35" (212 mm)

20.5" (521 mm) 16.37" (416 mm)

24.71" (628 mm) 16.37" (416 mm)

1.25" (32 mm) 11.65" (296 mm)

19.59" (498 mm)

KXE Ballast Ballast Tank KXD Tank KG40 Optics Globe KPE40 Optic

7.56" dia, (584 (192 mm) mm)

23.0" dia.

12.12" dia, (308 mm)

1.62" (41 mm) 18.25" dia. (464 mm)

23.0" dia, (584 mm)

KXE Ballast Tank 12" Spun Top Refractor Optics

132

KXE Ballast Tank KEP40 Optic


23.0" dia. (584 mm)

KXE Ballast Tank KER40 Enclosed Reflector KERG Wire Guard

7.56" dia. (192 mm) 9.56" dia. (245 mm)

KXE Ballast Tank KG40 Optics Globe KAG40S Wire Guard

Features

kEmLUx ii ks sEriEs
EncLosED/gAskEtED

For use in corrosive, wet and dirty industrial applications such as power generation, waste water and sewage treatment, pulp/paper or steel mills. Electro-Reg ballast provides long life, high lumen maintenance metal halide light source for low operating and maintenance costs. Cover selection of rigid and flexible pendant, ceiling, wall and 25 stanchion in varying threaded NPT entries. Minimum starting temperature of -20F for MV/MH and -40F for HPS and Electro-Reg. Copper-free (<0.4%) aluminum housing, cover and guard with white Lektrocote powder polyester paint finish provides excellent corrosion resistance from most chemicals. Optic choices of impact-resistant glass globe, symmetric/asymmetric glass refractors, dome/angle fiberglass reinforced polyester reflector, 19" enclosed reflector, and polycarbonate enclosed lowbay. Modular design permits selection of cover, body, globe, guard and reflector for custom applications. UL1598 Wet Locations; NEMA 4X with K-G globe, 55C ambient listed.

ordering Information Example:

KS

17
Watts

H
Lamp

8
Volts

G
optical Assembly

P2
Mount

UP
options

Series

Series Kemlux Harsh/Severe KS Wattage Medium Housing 50 50W HPS 70 70W HPS, MH (Pulse Start) 1 10 100W MV, HPS, MH (Pulse Start)1 15 150W HPS 17 175W MV, MH, Electro-Reg MH, Pulse Start 25 250W MV, MH Large Housing 25 250W HPS or Pulse Start 40 400W MV, MH, HPS, Electro-Reg MH, Pulse Start Lamp Type Mercury Vapor (MV) C Metal Halide (MH) H High Pressure Sodium (HPS) S Electro-Reg MH (lamp included) E Pulse Start (PS) W Voltage 120V (50W HPS and Electro-Reg 1 MH) 208V (For 175/400W Electro-Reg 2 MH only) 240V (Electro-Reg) 3 277V (50W HPS only) 4 480V (not available for 50W HPS) 5 Tri-Tap (120, 277, 347V)2, 3 6 (not available Electro-Reg) Quad Tap (120, 208, 240, 277V)3 8 (not available Electro-Reg) 220/240V 50 Hz3 E F 347V

optical Assembly Medium Housing g Globe Reflector/Polycarbonate Refractor X (50-150W HPS)4 Medium or Large Housing Symmetrical Glass Refractor L Large Housing Asymmetrical Glass Refractor M Enclosed Reflector E Mounting 3/4 Balancing Pendant B2 3/4 Balancing Pendant for B6 Electro-Reg C2 3/4 Ceiling 1 Ceiling C3 1 1/4 Stanchion D4 1 1/2 Stanchion D5 1 1/4 Stanchion for Electro-Reg D8 D9 1 1/2 Stanchion for Electro-Reg P2 3/4 Pendant 1 Pendant P3 3/4 Pendant for Electro-Reg P6 P7 1 Pendant for Electro-Reg W2 3/4 Wall 1 Wall W3 3/4 Wall for Electro-Reg W6 W7 1 Wall for Electro-Reg

options Fusing (X indicates voltage)5, 6 F(X) QS Quartz Standby (restart time MH = 5 min; HPS - 1 min) QT Time Delay Quartz Standby Hot restrike (70-150W HPS only) RS Photocontrol (not available for PC ceiling mount; Quad-Tap only) Unit Pack - Mounting adapter, UP ballast housing; Globe and/or Guard in same carton (medium housing only); reflector shipped separately Factory assembled - Lamp and FA globe installed onto housing; includes mounting adapter and/or guard (medium housing only); Reflector shipped separately
1 2 3 4 5 6 70W and 100W metal halide includes lamp. 250W MH with Tri-Tap ballast requires deeper Electro-Reg mounting adapter. Electro-Reg is not available. Consult factory for use with 150W MH U.V. Guard lamp. To specify voltage, replace X with 1-120V, 2-208V, 3-240V, 4-277V, 5-480V, F-347V. Not offered with CSA listing.

SEALED

Accessories - order Separately


Catalog Number K-10 K-20 K-30 K-06 K-07 K-SC6 Description Cast Guard for K-G globe Steel wire guard for K-L and K-M glass refractors. (Zinc plated) Steel wire guard for K-E enclosed reflector. (Painted) Standard dome reflector for K-G globe. (FRP) 30 angle reflector for K-G globe. (FRP) 6 safety chain (large housing only - order separately). Weight lbs. (kg) 1 (0.5) 2 (0.9) 1 (0.5) 1 (0.5) 1 (0.5)

133

kEmLUx ii ks sEriEs
Dimensions
Medium Housing
globe (K-g), guard (K-10), Dome (K-06) globe (K-g), Angle Dome ( K-07)

B C A
A 16 3/8 416 mm B 4 3/4 121 mm

B D
D 14 1/2 368 mm

C A
A 11 1/4 286 mm B 4 3/4 121 mm

C 5 5/8 143 mm

C 10 1/4 260 mm

D 15 381 mm

glass Refractor (K-L)

Reflector/Polycarbonate Refractor (K-X)

B C A
A 12 1/4 311 mm B 4 3/4 121 mm C 13 5/16 338 mm D 18 7/16 468 mm A 16 406 mm

D
A
B 4 3/4 121 mm

C 11 1/2 292 mm

D 16 1/4 413 mm

SEALED

Large Housing
Enclosed Reflector (K-E), guard (K-30) Refractor (K-L, K-M), guard (K-20)

B C A
A 19 483 mm B 6 1/16 154 mm

E
A
D 3 1/2 89 mm E 22 1/4 565 mm A 13 1/4 337 mm B 6 1/16 154 mm C 5 3/4 146 mm

B C E D
D 7 9/16 192 mm E 19 3/4 502 mm

C 12 5/8 321 mm

Mounting Adapters
A B
Top View

J D A
KS-B2

A
KS-P2, KS-P3

A
F 17 1/8 435 mm

g F
H 16 1/2 419 mm

I A
KS-W 2

K L
K 5 5/8 143 mm L 45 -

H
J 5 127 mm

KS-D4, KS- D5

A 12 1/4 311 mm

B 10 254 mm

C 7 1/16 179 mm

D 7/8 22 mm

E 2 3/16 56 mm

g 3 1/2 89 mm

I 4 7/16 113 mm

Electro-Reg/Ceiling Mounting Adapters


A B
Top View

F A E
KS-W6, KS-W7

H A D
KS-D8, KS-D9

A C
KS-B6

KS-C2, KS-C3, KS-P6, KS-P7

A 13 1/2 343 mm

B 10 254 mm

C 2 1/4 57 mm

D 18 1/4 464 mm

E 17 5/8 448 mm

F 4 7/8 124 mm

g 4 3/4 121 mm

H 5 15/16 151 mm

I 3 9/16 90 mm

134

Components

kEmLUx ii ks sEriEs
Description Pendant Pendant Ceiling (Also for Electro-Reg) Ceiling (Also for Electro-Reg) 25 Stanchion 25 Stanchion Wall Wall Balancing Pendant Pendant/Electro-Reg Pendant/Electro-Reg 25 Stanchion/Electro-Reg 25 Stanchion/Electro-Reg Wall/Electro-Reg Wall/Electro-Reg Hubs Size 3/4 1 3/4 1 1 1/4 1 1/2 3/4 1 3/4 3/4 1 1 1/4 1 1/2 3/4 1 Qty. 1 1 4 4 1 1 4 4 1 1 1 1 1 1 4 Plugs Qty. 3 3 3 3 3 Weight lbs. (kg) 1.5 (0.7) 1.5 (0.7) 2.0 (0.9) 2.0 (0.9) 4.0 (1.8) 4.0 (1.8) 4.0 (1.8) 4.0 (1.8) 2.0 (0.9) 4.5 (2.0) 4.5 (2.0) 4.5 (2.0) 4.5 (2.0) 4.5 (2.0) 4.5 (2.0)

The following mounting adapters are available for the KH Series. They can be ordered separately or refer to Catalog Logic for complete fixture.
Catalog Number KS-P2 KS-P3 KS-C2 KS-C3 KS-D4 KS-D5 KS-W2 KS-W3 KS-B2 KS-P61, 2 KS-P71, 2 KS-D82 KS-D92 KS-W62 KS-W72

ordering Information: KS Mounting Adapters

ordering Information: KS 50-400W Ballast Housing


Catalog Number Wattage 50W 70W 100W 150W Voltage 120 277 120/208/240/277 480 120/208/240/277 480 120/208/240/277 480 120/208/240/277 175W 480 120/208/240/277 250W 480 120/208/240/277 400W 480
1 2 3 4

High Pressure Sodium KS50S1 KS50S4 KS70S8 KS70S5 KS10S8 KS10S5 KS15S8 KS15S5 KS25S8 KS25S5 KS40S8 KS40S5

Mercury Vapor KS10C8 KS10C5 KS17C8 KS17C5 KS25C8 KS25C5 KS40C8 KS40C5

Metal Halide KS70H8 KS70H5 KS10H8 KS10H5 KS17H8 KS17EX3 KS17H5 KS17E5 KS25H8 KS25EX3, 4 KS25H5 KS25E5 KS40H8 KS40EX4 KS40H5 KS40E5

SEALED

Same adapter as ceiling mount except one drilled and tapped entry on top and blank entries on sides. 250W MH with Tri-Tap ballast requires the deeper Electro-Reg mounting adapter For Electro-Reg, replace X with 1 = 120V; 2 = 208V; 3 = 240V; 4 = 277V; 5 = 480V; F = 347V for line voltage. Example: KS17E1 Not available in 208V.

ordering Information: optical Assemblies


Catalog Number K-g K-E K-L K-M K-X Description Prismatic, heat resistant glass globe (medium housing only) 19 enclosed reflector Symmetrical (Type V) glass refractor Asymmetrical (Type II) glass refractor Reflector/Polycarbonate Refractor (medium housing only) Weight lbs. (kg) 2 (0.9) 7 (3.2) 13 (5.9) 13 (5.9) -

135

vAportitE nv-sEriEs
EncLosED/gAskEtED

Features

Typical applications include manufacturing plants, chemical and petrochemical processing facilities, sewage treatment plants, off-shore and dockside installations, agricultural, commercial, industrial, mining, and marine facilities. NV2 Series non-metallic light fixtures combine an outstanding balance of strength, stiffness, toughness and electrical properties. Energy and labor saving fluorescent or incandescent models. Accessories include polycarbonate dome reflectors and wall extension. Molded from 30% glass-filled thermoset polyester for high strength. Resists corrosive effects of most chemicals, hydrocarbons and solvents. Designed for indoor and outdoor applications. UL1598 Standard for luminaires. UL 1598 Marine type luminaires. UL 844 Standard for lighting fixtures for hazardous locations. CSA C22.2 no. 137-M1981 electric luminaires for use in hazardous locations. Enclosed and gasketed. NEMA 3, 4X IP66.

Class I, Div. 2, groups A, B, C, D Class I, Zone 2, groups IIC, IIB, IIA Class II, Div. 2, groups F, g, C, D Class III NEMA 4X, IP66, Marine Rated

ordering Information
Catalog Number Type Standard globe Tempered globe Pendant 3/4 Fixture with Clear globe & guard NV2Ig15ASg NV2Ig15AHg 150A Incandescent NV2Fg13ASg NV2Fg13AHg 13W Fluorescent NV2Fg18ASg NV2Fg18AHg 18W Fluorescent 26W Fluorescent NV2Fg26ASg NV2Fg26AHg NV2Fg32ASg NV2Fg32AHg 32W Fluorescent NV2Fg42ASg NV2Fg42AHg 42W Fluorescent Ceiling 3/4 Fixture with Clear globe & guard NV2Ig15XSg NV2Ig15XHg 150A Incandescent 13W Fluorescent NV2Fg13XSg NV2Fg13XHg NV2Fg18XSg NV2Fg18XHg 18W Fluorescent NV2Fg26XSg NV2Fg26XHg 26W Fluorescent NV2Fg32XSg NV2Fg32XHg 32W Fluorescent NV2Fg42XSg NV2Fg42XHg 42W Fluorescent Wall 3/4 Fixture with Clear globe & guard NV2Ig15BSg NV2Ig15BHg 150A Incandescent NV2Fg13BSg NV2Fg13BHg 13W Fluorescent 18W Fluorescent NV2Fg18BSg NV2Fg18BHg NV2Fg26BSg NV2Fg26BHg 26W Fluorescent 32W Fluorescent NV2Fg32BSg NV2Fg32BHg NV2Fg42BSg NV2Fg42BHg 42W Fluorescent
Notes Tempered Globes are required for Wet Location applications. All assemblies are unit packed with required components (not assembled). Fluorescent unit pack models (only) include the lamp. Reflector is sold separately. For wall mounting with reflector, the NVEXTG extension is required and sold separately. Fluorescent models use world voltage ballasts for 120VAC through 277VAC 50/60Hz applications.

Components1
Catalog Number NV2Ag NV2Xg NV2Bg NV2gg NV2Ig15 NV2Fg13 NV2Fg18 NV2Fg26 NV2Fg32 NV2Fg42 NVPSD12 NVEXTg NV2Cg NV2CC
1

Description 3/4 Pendant Splice Box 3/4 Ceiling Splice Box (M20 entryNV2MG) Elbow (used between NV2Xg & fixture body) Guard Incandescent Body with socket 13W Fluor. Body 120VAC - 277V 50/60Hz 18W Fluor. Body 120VAC - 277V 50/60Hz 26W Fluor. Body 120VAC - 277V 50/60Hz 32W Fluor. Body 120VAC - 277V 50/60Hz 42W Fluor. Body 120VAC - 277V 50/60Hz White Reflector (secured by guard) Extension (for wall mount with reflector) Gray Blank Cover for NV2XG Clear Cover for NV2Xg

Fluorescent bodies only do not include lamps.

Colored globe options2


Suffix Standard Suffix Tempered globe globe A A B B R R g N/A P N/A Bg Bg
2

Description Amber Blue Ruby Green Purple Blue-Green

Tempered Globes are required for Wet Location applications.

Dimensions
2.12" (54 mm) 1.15" (29 mm) .33 TYP. (8 mm) 5.19" (102 mm) VOLUME 24 CU. IN.

Wall
4.53" (115 mm) 1.15" (29 mm)

Wall Fluorescent w/ extension & dome reflector


1.15" (29 mm) 13.78" (350 mm)

4.53" (115 mm) INCANDESCENT 11.20" (285 mm) FLUORESCENT 12.31" (340 mm)

4.53" (115 mm) INCANDESCENT 12.26" (311 mm) FLUORESCENT 13.37" (340 mm)

INCANDESCENT 10.84" (275 mm) FLUORESCENT 11.95" (304 mm)

INCANDESCENT 12.26" (311 mm) FLUORESCENT 13.37" (340 mm)

136

Pendant

Ceiling

11.69" (297 mm)

Features

BYMB SERIES
oBSTRUCTIoN LIgHTS

For use as obstruction indication for buildings and towers. Availale in single or twin version wtih steady burning incandescent lamp. Lens mounted in cast aluminum ring and secured with SS thumb screw and safety chain. Twin unit can operate both lamps simultaneously. Relay accessory provides switching when lamp on first luminaire fails. Traffic signal lamp 116A-21/TS has rated life of 8,000 hours on 120 volt line, and 22,000 hours on 130 volt line (lamp not included). Mounting hub is 1 NPS. Housing Heavy-duty cast aluminum. Glass Fresnel lens in clear or selected colors.

ordering Information Example:


Catalog Number BYMB-3600-AHQ BYMB-36002-AHQ 7AP53 7AP53B 7AP53g 7AP53R1 7AP53Y 7AP3A
1

Description Incandescent single units - less lens Incandescent twin units - less lenses Clear lens Blue lens Green lens Red lens Amber lens Internal relay to change lamps on twin unit

Dimensions 5 1/8 x 14 14 3/4 x 14

Amps 0.82 0.82 or 1.6

MISCELLANEoUS

ETL verified to FAA specification AC No. 150/5343-43E

Dimensions
Single
C B A
A 14 3/4 Twin 375 mm 14 Single 356 mm B 9 5/8 244 mm 6 5/8 168 mm C 6 5/8 168 mm 5 1/8 130 mm D 14 356 mm -

Twin
A B C D

137

photocELL
cLAss i Division 2

Photocontrol for Standard & Hazardous Class I Division 21

ordering Information
Catalog Number HUB2PC120 HUB2PC2772 HUB2PC347
1 2

Volts 120VAC 277VAC 347VAC

Frequency 50/60 Hz 50/60 Hz 50/60 Hz


NOTE Patent Pending.

Watts 400 400 400

Photocontrol cells for Class I Division 2 only. Marked 220-277V, suitable for 208V.

Factory Installed option (add as suffix)


Suffix -P1 -P2 -P3 Voltage 120V 208-277V 347V

Field installed in Splice Cap

Factory installed in Ballast Tank

pEnDAnt hAngErs
EncLosED & gAskEtED
HLV Series

MISCELLANEoUS

HLFKA Series

Provide flexible and rigid pendant mounting. Flexible mount permits angular displacement (5) and cushioning for shock absorption. Internal strap ensure continuity. Available in four hub configurations. Hanger uses male threads for attachement to conduit system and female threads for fixture stem. Ball joint permits fixture to hang plumb and swing 20 from vertical. Set screw locks fixture stem in place. thru-feed hub configuration. Ball joint permits fixture to hang plumb and swing 20 from vertical. Set screw locks fixture stem in place. HLV, HLFKA, HLFH Copper-free (<0.4%) aluminum alloy. All series suitable for fixture weighing up to 125 lbs.

HLFH Series

ordering Information
HLFKA Series
Catalog Number HLFKA22 Fixture Stem Size 3/4 Male Thread 3/4

HLV Series - Hangers


Catalog Number HLVgA2
HLFKA

HLV Series - Covers


Catalog Number HLVg2 HLVPFH2 Description Rigid Hub Hanger Flexible, Swivel Fixture Stem Size 3/4 3/4

HLVgC2 HLVgH2 HLVgX2

Splice Box Size Pendant 3/4 Ceiling 3/4 3/4 3/4

Hub Quantity 1 2 1 4

HLFH Series
Catalog Number HLFHC22 HLFHT22

HLVG2 Rigid Hanger Cover

HLVPFH2 Flexible Hanger Cover 5 Swing

HLVGA2

HLVGC2

HLVGH2

HLVGX2

Dimensions
HLFKA22
B A HLFH
A 3 1/8 79 mm B 3 1/2 89 mm A 3 1/2 89 mm B 4 1/8 105 mm

HLFH
A B

Conduit Size Fixture Stem Size Two Hubs Thru 3/4 3/4 Three Hubs Thru 3/4 3/4

138

Features
HLEKJ Series

pEnDAnt hAngErs

ExpLosion proof

Flexible pendant hanger in lengths from 4 to 24 with male hubs. Constructed of seamless bronze hose with brass out braid. UL 844: Class I, Div. 1/2 Groups A, B, C, D; Class II Div. 1/2 Groups E, F, G; Class III, Div. 1/2. Rigid, thru-feed hanger with conduit hubs and - fixture stems. Mounting lugs on conduit hubs. Conduit openings in two configurations, flange type cover. Integral lugs for mounting box to ceiling. Flange mounting ring cast integral to box. Support up to 125 lbs. Copper-free (<0.4%) aluminum construction. UL 844: Class I, Div. 1/2 Groups C, D; Class II, Div. 1/2 Groups E, F, G; Class III, Div. 1/2.

HLXFH Series

HLJL/HLJAL Series HLHXB Series

HLFXH, HLJL, HLJAL, HLHXB Series

ordering Information
HLEKJ Series
Catalog Number HLEKJ24 HLEKJ26 HLEKJ28 HLEKJ210 HLEKJ212 HLEKJ215 HLEKJ218 HLEKJ224 Conduit Size 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 Flexible Length 4 6 8 10 12 15 18 24

HLXFH Series
Catalog Number HLXFH21 HLXFH22 Conduit Hub Size 3/4 3/4 Fixture Stem Size 1/2 3/4

MISCELLANEoUS

HLJL/HLJAL Series
Catalog Number HLJLC22 HLJALX22 HLJALX32
Note

HLHXB Series
Type C Straight Thru X Four Hubs X Four Hubs Catalog Number HLHXB22 HLHXB11 HLHXB12 HLHXB21 HLHXBC Conduit Hub Size 3/4 1/2 1/2 3/4 Blank Cover Fixture Stem Size 3/4 1/2 3/4 1/2 -

Conduit Size Box Cover 3/4 (19 mm) 3/4 (19 mm) 3/4 (19 mm) 3/4 (19 mm) 1 (25 mm) 3/4 (19mm)

HLJALX supplied with three close-up plugs.

HLJL

HLJAL

HLXFH
A B E D

HLJL/HLJAL

I I I I I
I
I I I I I

I I I

A 1/4 6 mm

B 5 1/8 130 mm

C 5/8 16 mm

D 4 1/2 114 mm

E 2 3/8 60 mm

A 1 15/16 HLJL 49 mm 2 3/8 HLJAL 60 mm

I I II I I

B 11/16 17 mm 1 5/32 29 mm

C 3 1/4 83 mm 4 5/8 117 mm

D 4 7/32 107 mm 5 1/4 133 mm

E 2 3/8 60 mm 4 1/8 105 mm

F 5/16 8 mm 5/16 8 mm

139

QUICK ESTIMATORS
CH-OU, CH-EU, CH-SW
To determine the number of luminaires required for a given illuminance level:

Step 1: Determine room size per column three below as 5 or more (Large
Room), 2 (Medium Room) or 1 (Small Room.

Step 2: For desired footcandle level, per room size, divide floor area of space
by Approximate Area per Luminaire from chart.

Step 3: If required, adjust result of Step 2 to whole number. Result is quantity


of luminaires required to provide approximate, average maintained illuminance selected.

CH-OU
LAMP QTY-LU/LP INPUT WATTS MS250/BU/PS (ENC) 1 @ 23800 292 MS400/BU/PS 1 @ 44000 452 MH400/U 1 @ 36000 458 SC @2/@4 LLF TEST # 2.0/1.7 0.57 HP-06476 1.7/1.6 0.60 HP-06163 1.7/1.6 0.57 HP-06163 ROOM WIDTH -/MOUNTING HEIGHT (above floor) 5 or more 2 1 5 or more 2 1 5 or more 2 1 ILLUMINANCE (MAINTAINED) APPROXIMATE AREA PER LUMINAIRE (SQ. FT.) / APPROXIMATE WATTS PER SQ. FT. (w/Blst. Losses) 10 fc 20 fc 50 fc 75 fc 100 fc 1075 / 0.27 538 / 0.54 215 / 1.36 143 / 2.04 n.r. / n.r. 830 / 0.35 415 / 0.70 166 / 1.76 111 / 2.64 n.r. / n.r. 613 / 0.48 306 / 0.95 123 / 2.38 82 / 3.58 n.r. / n.r. 2265 / 0.20 1132 / 0.40 453 / 1.00 302 / 1.50 226 / 2.00 1764 / 0.26 882 / 0.51 353 / 1.28 235 / 1.92 176 / 2.56 1317 / 0.34 658 / 0.69 263 / 1.72 176 / 2.57 132 / 3.43 1774 / 0.26 887 / 0.52 355 / 1.29 236 / 1.94 177 / 2.58 1382 / 0.33 691 / 0.66 276 / 1.66 184 / 2.49 138 / 3.31 1031 / 0.44 516 / 0.89 206 / 2.22 137 / 3.33 103 / 4.44

CH-EU
LAMP QTY-LU/LP INPUT WATTS MS250/BU/PS 1 @ 23800 292 MS400/BU/PS 1 @ 44000 452 MH400/U 1 @ 36000 458 SC @2/@4 LLF TEST # 1.9/1.6 0.59 HP-06467 1.5/1.5 0.59 HP-06188 1.5/1.5 0.56 HP-06188 ROOM WIDTH -/MOUNTING HEIGHT (above floor) 5 or more 2 1 5 or more 2 1 5 or more 2 1 ILLUMINANCE (MAINTAINED) APPROXIMATE AREA PER LUMINAIRE (SQ. FT.) / APPROXIMATE WATTS PER SQ. FT. (w/Blst. Losses) 10 fc 20 fc 50 fc 75 fc 100 fc 1128 / 0.26 564 / 0.52 226 / 1.29 150 / 1.94 n.r. / n.r. 877 / 0.33 439 / 0.67 175/ 1.66 117 / 2.50 n.r. / n.r. 655 / 0.45 327 / 0.89 131 / 2.23 87 / 3.35 n.r. / n.r. 2086 / 0.22 1043 / 0.43 417 / 1.08 278 / 1.63 209 / 2.17 1648 / 0.27 824 / 0.55 330 / 1.37 220 / 2.06 165 / 2.74 1236 / 0.37 618 / 0.73 247 / 1.83 165 / 2.74 124 / 3.66 1633 / 0.28 817 / 0.56 327 / 1.40 218 / 2.10 163 / 2.80 1291 / 0.35 645 / 0.71 258 / 1.77 172 / 2.66 129 / 3.55 968 / 0.47 484 / 0.95 194 / 2.37 129 / 3.55 97 / 4.73

CH-SW
LAMP QTY-LU/LP INPUT WATTS MS250/BU/PS 1 @ 23800 292 MS400/BU/PS 1 @ 44000 452 MH400/U 1 @ 36000 458 SC @2/@4 LLF TEST # 2.3/2.1 0.57 HP-06356 2.3/2.1 0.60 HP-06354 2.3/2.1 0.57 HP-06354 ROOM WIDTH -/MOUNTING HEIGHT (above floor) 5 or more 2 1 5 or more 2 1 5 or more 2 1 ILLUMINANCE (MAINTAINED) APPROXIMATE AREA PER LUMINAIRE (SQ. FT.) / APPROXIMATE WATTS PER SQ. FT. (w/Blst. Losses) 10 fc 20 fc 50 fc 75 fc 100 fc 1059 / 0.28 529 / 0.55 212 / 1.38 141 / 2.07 n.r. / n.r. 682 / 0.43 341 / 0.86 136 / 2.14 91 / 3.21 n.r. / n.r. 460 / 0.64 230 / 1.27 92 / 3.18 61 / 4.76 n.r. / n.r. 1957 / 0.23 978 / 0.46 391 / 1.15 261 / 1.73 196 / 2.31 1287 / 0.35 644 / 0.70 257 / 1.76 172 / 2.63 129 / 3.51 875 / 0.52 438 / 1.03 175 / 2.58 117 / 3.87 88 / 5.16 1532 / 0.30 766 / 0.60 306 / 1.49 204 / 2.24 153 / 2.99 1008 / 0.45 504 / 0.91 202 / 2.27 134 / 3.41 101 / 4.54 686 / 0.67 343 / 1.34 137 / 3.34 91 / 5.01 69 / 6.68

140

QUICK ESTIMATORS
CH-OU60, CH-EU60, CH-LM
To determine the number of luminaires required for a given illuminance level:

Step 1: Determine room size per column three below as 5 or more (Large
Room), 2 (Medium Room) or 1 (Small Room.

Step 2: For desired footcandle level, per room size, divide floor area of space
by Approximate Area per Luminaire from chart.

Step 3: If required, adjust result of Step 2 to whole number. Result is quantity


of luminaires required to provide approximate, average maintained illuminance selected.

CH-OU60
LAMP QTY-LU/LP INPUT WATTS MH1000/U 1 @ 110000 1080 SC @2/@4 LLF TEST # 1.6/1.4 0.56 HP-06171A ROOM WIDTH -/MOUNTING HEIGHT (above floor) 5 or more 2 1 ILLUMINANCE (MAINTAINED) APPROXIMATE AREA PER LUMINAIRE (SQ. FT.) / APPROXIMATE WATTS PER SQ. FT. (w/Blst. Losses) 10 fc 20 fc 50 fc 75 fc 100 fc 5196 / 0.21 2598 / 0.42 1039 / 1.04 693 / 4.56 520 / 2.08 4157 / 0.26 2079 / 0.52 831 / 1.30 554 / 1.95 416 / 2.60 3301 / 0.33 1651 / 0.65 660 / 1.64 440 / 2.45 330 / 3.27

CH-EU60
LAMP QTY-LU/LP INPUT WATTS MH1000/U 1 @ 110000 1080 SC @2/@4 LLF TEST # 1.5/1.3 0.54 HP-06186A ROOM WIDTH -/MOUNTING HEIGHT (above floor) 5 or more 2 1 ILLUMINANCE (MAINTAINED) APPROXIMATE AREA PER LUMINAIRE (SQ. FT.) / APPROXIMATE WATTS PER SQ. FT. (w/Blst. Losses) 10 fc 20 fc 50 fc 75 fc 100 fc 4662 / 0.23 2331 / 0.46 932 / 1.16 622 / 1.74 466 / 2.32 3766 / 0.29 1883 / 0.57 753 / 1.43 502 / 2.15 377 / 2.87 2989 / 0.36 1494 / 0.72 598 / 1.81 398 / 2.71 299 / 3.61

CH-LM
LAMP QTY-LU/LP INPUT WATTS MS250/BU/PS 1 @ 23800 292 MS400/BU/PS 1 @ 44000 452 MH400/U 1 @ 36000 458 MVR750/VBU/PA 1 @ 82000 787 @ Q SC @2/@4 LLF TEST # 1.7/2.1 0.59 HP-06290 1.7/2.0 0.59 HP-06283 1.7/2.0 0.56 HP-06283 1.7/2.0 0.61 HP-08949 ROOM WIDTH -/MOUNTING HEIGHT (above floor) 5 or more 2 1 5 or more 2 1 5 or more 2 1 5 or more 2 1 ILLUMINANCE (MAINTAINED) APPROXIMATE AREA PER LUMINAIRE (SQ. FT.) / APPROXIMATE WATTS PER SQ. FT. (w/Blst. Losses) 10 fc 20 fc 50 fc 75 fc 100 fc 1072 / 0.27 536 / 0.54 214 / 1.36 143 / 2.04 n.r. / n.r. 710 / 0.41 355 / 0.82 142 / 2.06 95 / 3.08 n.r. / n.r. 487 / 0.60 244 / 1.20 97 / 3.00 65 / 4.49 n.r. / n.r. n.r. / n.r. 1030 / 0.44 412 / 1.10 275 / 1.65 206 / 2.19 n.r. / n.r. 682 / 0.66 273 / 1.66 182 / 2.48 136 / 3.31 n.r. / n.r. 476 / 0.95 191 / 2.37 127 / 3.56 95 / 4.74 1613 / 0.28 807 / 0.57 323 / 1.42 215 / 2.13 161 / 2.84 1069 / 0.43 534 / 0.86 214 / 2.14 142 / 3.21 107 / 4.29 746 / 0.61 373 / 1.23 149 / 3.07 99 / 4.60 75 / 6.14 n.r. / n.r. 1852 / 0.43 741 / 1.06 494 / 1.59 370 / 2.13 n.r. / n.r. 1251 / 0.63 500 / 1.57 334 / 2.36 250 / 3.15 n.r. / n.r. 851 / 0.93 340 / 2.31 227 / 3.47 170 / 4.63

141

QUICK ESTIMATORS
BL-WA22, BL-PA2, BL-LB1
To determine the number of luminaires required for a given illuminance level:

Step 1: Determine room size per column three below as 5 or more (Large
Room), 2 (Medium Room) or 1 (Small Room.

Step 2: For desired footcandle level, per room size, divide floor area of space
by Approximate Area per Luminaire from chart.

Step 3: If required, adjust result of Step 2 to whole number. Result is quantity


of luminaires required to provide approximate, average maintained illuminance selected.

BL-WA22
LAMP QTY-LU/LP INPUT WATTS SC @2/@4 LLF TEST # ROOM WIDTH -/MOUNTING HEIGHT (above floor) 5 or more 2 1 5 or more 2 1 5 or more 2 1 ILLUMINANCE (MAINTAINED) APPROXIMATE AREA PER LUMINAIRE (SQ. FT.) / APPROXIMATE WATTS PER SQ. FT. (w/Blst. Losses) 10 fc 20 fc 50 fc 75 fc 100 fc 1062 / 0.27 531 / 0.55 212 / 1.37 142 / 2.06 n.r. / n.r. 835 / 0.35 417 / 0.70 167 / 1.75 111 / 2.62 n.r. / n.r. 658 / 0.44 329 / 0.89 132 / 2.22 88 / 3.33 n.r. / n.r. 2286 / 0.20 1143 / 0.40 457 / 0.99 305 / 1.48 229 / 1.98 1742 / 0.26 871 / 0.52 348 / 1.30 232 / 1.95 174 / 2.60 1361 / 0.33 680 / 0.66 272 / 1.66 181 / 2.49 136 / 3.32 1790 / 0.26 895 / 0.51 358 / 1.28 239 / 1.92 179 / 2.56 1364 / 0.34 682 / 0.67 273 / 1.68 182 / 2.52 136 / 3.36 1066 / 0.43 533 / 0.86 213 / 2.15 142 / 3.22 107 / 4.30

MVR250/C/VBU/PA (ENC) 1.5/1.3 1 @ 21500 0.59 292 HP-08211 MS400/BU/PS 1.5/1.3 1 @ 44000 0.62 452 HP-08144 MH400/U 1.5/1.3 1 @ 36000 0.59 458 HP-08144

BL-PA2
LAMP QTY-LU/LP INPUT WATTS MVR250/C/VBU/PA 1 @ 21500 292 MS400/BU/PS 1 @ 44000 452 MH400/U 1 @ 36000 458 SC @2/@4 LLF TEST # 1.8/1.5 0.59 LTL-01783 1.8/1.6 0.62 HP-07676 1.8/1.6 0.59 HP-07676 ROOM WIDTH -/MOUNTING HEIGHT (above floor) 5 or more 2 1 5 or more 2 1 5 or more 2 1 ILLUMINANCE (MAINTAINED) APPROXIMATE AREA PER LUMINAIRE (SQ. FT.) / APPROXIMATE WATTS PER SQ. FT. (w/Blst. Losses) 10 fc 20 fc 50 fc 75 fc 100 fc 986 / 0.30 493 / 0.59 197 / 1.36 132 / 2.22 n.r. / n.r. 734 / 0.40 367 / 0.80 147 / 1.76 98 / 2.99 n.r. / n.r. 544 / 0.54 272 / 1.07 109 / 2.38 73 / 4.03 n.r. / n.r. 2231 / 0.20 1116 / 0.41 446 / 1.00 298 / 1.52 223 / 2.03 1633 / 0.28 816 / 0.55 327 / 1.28 218 / 2.08 163 / 2.77 1197 / 0.38 599 / 0.76 239 / 1.72 160 / 2.83 120 / 3.78 1747 / 0.26 874 / 0.52 349 / 1.29 233 / 1.97 175 / 2.62 1279 / 0.36 639 / 0.72 256 / 1.66 170 / 2.69 128 / 3.58 938 / 0.49 469 / 0.98 188 / 2.22 125 / 3.66 94 / 4.88

BL-LB1
LAMP QTY-LU/LP INPUT WATTS MS250/BU/PS 1 @ 23800 292 MS400/BU/PS 1 @ 44000 452 MH400/U 1 @ 36000 458 SC @2/@4 LLF TEST # 1.6/1.5 0.59 HP-05619 1.5/1.5 0.59 HP-05685 1.5/1.5 0.56 HP-05685 ROOM WIDTH -/MOUNTING HEIGHT (above floor) 5 or more 2 1 5 or more 2 1 5 or more 2 1 ILLUMINANCE (MAINTAINED) APPROXIMATE AREA PER LUMINAIRE (SQ. FT.) / APPROXIMATE WATTS PER SQ. FT. (w/Blst. Losses) 10 fc 20 fc 50 fc 75 fc 100 fc 1017 / 0.29 508 / 0.57 203 / 1.44 136 / 2.15 n.r. / n.r. 724 / 0.40 362 / 0.81 145 / 2.02 97 / 3.02 n.r. / n.r. 529 / 0.55 265 / 1.10 103 / 2.76 71 / 4.14 n.r. / n.r. 1983 / 0.23 991 / 0.46 397 / 1.14 264 / 1.71 198 / 2.28 1390 / 0.33 695 / 0.65 278 / 1.63 185 / 2.44 139 / 3.25 1030 / 0.44 515 / 0.88 206 / 2.19 137 / 3.29 103 / 4.39 1553 / 0.29 776 / 0.59 311 / 1.47 207 / 2.21 155 / 2.95 1089 / 0.42 544 / 0.84 218 / 2.10 145 / 3.15 109 / 4.21 807 / 0.57 403 / 1.14 161 / 2.84 108 / 4.26 81 / 5.68

142

QUICK ESTIMATORS
BL-HG16, BL-HG22, BL-EG
To determine the number of luminaires required for a given illuminance level:

Step 1: Determine room size per column three below as 5 or more (Large
Room), 2 (Medium Room) or 1 (Small Room.

Step 2: For desired footcandle level, per room size, divide floor area of space
by Approximate Area per Luminaire from chart.

Step 3: If required, adjust result of Step 2 to whole number. Result is quantity


of luminaires required to provide approximate, average maintained illuminance selected.

BL-HGX16
LAMP QTY-LU/LP INPUT WATTS MS320/BU/PS (ENC) 1 @ 31700 368 MS400/BU/PS 1 @ 44000 452 MH400/U 1 @ 36000 458 SC @2/@4 LLF TEST # 1.8/1.6 0.60 HP-08290 2.3/1.9 0.62 HP-08337 2.3/1.9 0.59 HP-08337 ROOM WIDTH -/MOUNTING HEIGHT (above floor) 5 or more 2 1 5 or more 2 1 5 or more 2 1 ILLUMINANCE (MAINTAINED) APPROXIMATE AREA PER LUMINAIRE (SQ. FT.) / APPROXIMATE WATTS PER SQ. FT. (w/Blst. Losses) 10 fc 20 fc 50 fc 75 fc 100 fc 1172 / 0.31 586 / 0.63 234 / 1.57 156 / 2.35 n.r. / n.r. 813 / 0.45 406 / 0.91 163 / 2.26 108 / 3.39 n.r. / n.r. 605 / 0.61 302 / 1.22 121 / 3.04 81 / 4.56 n.r. / n.r. 1878 / 0.24 939 / 0.48 376 / 1.20 250 / 1.81 188 / 2.41 1306 / 0.35 653 / 0.69 261 / 1.73 174 / 2.60 131 / 3.46 925 / 0.49 463 / 0.98 185 / 2.44 123 / 3.66 93 / 4.89 1470 / 0.31 735 / 0.62 294 / 1.56 196 / 2.34 147 / 3.11 1023 / 0.45 511 / 0.90 205 / 2.24 136 / 3.36 102 / 4.48 725 / 0.63 362 / 1.26 145 / 3.16 97 / 4.74 72 / 6.32

BL-HGX22
LAMP QTY-LU/LP INPUT WATTS MS320/BU/PS (ENC) 1 @ 31700 368 MS400/BU/PS 1 @ 44000 452 MH400/U 1 @ 36000 458 SC @2/@4 LLF TEST # 1.5/1.3 0.59 HP-04812 1.3/1.2 0.59 HP-04809 1.3/1.2 0.56 HP-04809 ROOM WIDTH -/MOUNTING HEIGHT (above floor) 5 or more 2 1 5 or more 2 1 5 or more 2 1 ILLUMINANCE (MAINTAINED) APPROXIMATE AREA PER LUMINAIRE (SQ. FT.) / APPROXIMATE WATTS PER SQ. FT. (w/Blst. Losses) 10 fc 20 fc 50 fc 75 fc 100 fc 1323 / 0.28 662 / 0.56 265 / 1.39 176 / 2.09 n.r. / n.r. 983 / 0.37 492 / 0.75 197 / 1.87 131 / 2.81 n.r. / n.r. 737 / 0.50 369 / 1.00 147 / 2.50 98 / 3.74 n.r. / n.r. 2123 / 0.21 1061 / 0.43 425 / 1.06 283 / 1.60 212 / 2.13 1605 / 0.28 803 / 0.56 321 / 1.41 214 / 2.11 161 / 2.82 1252 / 0.36 626 / 0.72 250 / 1.81 167 / 2.71 125 / 3.61 1662 / 0.28 831 / 0.55 332 / 1.38 222 / 2.07 166 / 2.76 1257 / 0.36 629 / 0.73 251 / 1.82 168 / 2.73 126 / 3.64 980 / 0.47 490 / 0.93 196 / 2.34 131 / 3.50 98 / 4.67

BL-EG
LAMP QTY-LU/LP INPUT WATTS MS250/BU/PS 1 @ 23800 292 MS400/BU/PS 1 @ 44000 452 MH400/U 1 @ 36000 458 SC @2/@4 LLF TEST # 1.5/1.6 0.59 HP-04812 1.6/1.7 0.59 HP-04809 1.6/1.7 0.56 HP-04809 ROOM WIDTH -/MOUNTING HEIGHT (above floor) 5 or more 2 1 5 or more 2 1 5 or more 2 1 ILLUMINANCE (MAINTAINED) APPROXIMATE AREA PER LUMINAIRE (SQ. FT.) / APPROXIMATE WATTS PER SQ. FT. (w/Blst. Losses) 10 fc 20 fc 50 fc 75 fc 100 fc 947 / 0.31 474 / 0.62 189 / 1.54 126 / 2.31 n.r. / n.r. 682 / 0.43 341 / 0.86 136 / 2.14 91 / 3.21 n.r. / n.r. 487 / 0.60 244 / 1.20 97 / 3.00 65 / 4.49 n.r. / n.r. 1828 / 0.25 914 / 0.49 366 / 1.24 244 / 1.85 183 / 2.47 1313 / 0.34 657 / 0.69 263 / 1.72 175 / 2.58 131 / 3.44 927 / 0.49 463 / 0.98 185 / 2.44 124 / 3.66 93 / 4.88 1432 / 0.32 716 / 0.64 286 / 1.60 191 / 2.4 143 / 3.20 1028 / 0.45 514 / 0.89 206 / 2.23 137 / 3.34 103 / 4.45 726 / 0.63 363 / 1.26 145 / 3.15 97 / 4.73 73 / 6.31

143

QUICK ESTIMATORS
NAH, BL-BI, BL-SU
To determine the number of luminaires required for a given illuminance level:

Step 1: Determine room size per column three below as 5 or more (Large
Room), 2 (Medium Room) or 1 (Small Room.

Step 2: For desired footcandle level, per room size, divide floor area of space
by Approximate Area per Luminaire from chart.

Step 3: If required, adjust result of Step 2 to whole number. Result is quantity


of luminaires required to provide approximate, average maintained illuminance selected.

BL-OU60
LAMP QTY-LU/LP INPUT WATTS MH1000/U 1 @ 110000 1080 SC @2/@4 LLF TEST # 1.6/1.4 0.56 HP-06171A ROOM WIDTH -/MOUNTING HEIGHT (above floor) 5 or more 2 1 ILLUMINANCE (MAINTAINED) APPROXIMATE AREA PER LUMINAIRE (SQ. FT.) / APPROXIMATE WATTS PER SQ. FT. (w/Blst. Losses) 10 fc 20 fc 50 fc 75 fc 100 fc 5196 / 0.21 2598 / 0.42 1039 / 1.04 693 / 4.56 520 / 2.08 4157 / 0.26 2079 / 0.52 831 / 1.30 554 / 1.95 416 / 2.60 3301 / 0.33 1651 / 0.65 660 / 1.64 440 / 2.45 330 / 3.27

BL-BI
LAMP QTY-LU/LP INPUT WATTS MH250/U (ENC) 1 @ 20500 290 MS400/BU/PS 1 @ 44000 452 MH400/U 1 @ 36000 458 SC @2/@4 LLF TEST # 1.5/1.5 0.54 HP-03848A 1.3/1.4 0.60 HP-03802 1.3/1.4 0.57 HP-03802 ROOM WIDTH -/MOUNTING HEIGHT (above floor) 5 or more 2 1 5 or more 2 1 5 or more 2 1 ILLUMINANCE (MAINTAINED) APPROXIMATE AREA PER LUMINAIRE (SQ. FT.) / APPROXIMATE WATTS PER SQ. FT. (w/Blst. Losses) 10 fc 20 fc 50 fc 75 fc 100 fc 884 / 0.33 442 / 0.66 177 / 1.64 118 / 2.46 n.r. / n.r. 663 / 0.44 332 / 0.87 133 / 2.19 88 / 3.28 n.r. / n.r. 497 / 0.58 249 / 1.17 99 / 2.91 66 / 4.37 n.r. / n.r. 2238 / 0.20 1119 / 0.40 448 / 1.01 298 / 1.51 224 / 2.02 1659 / 0.27 830 / 0.54 332 / 1.36 221 / 2.04 166 / 2.72 1238 / 0.37 619 / 0.73 248 / 1.83 165 / 2.74 124 / 3.65 1753 / 0.26 876 / 0.52 351 / 1.31 234 / 1.96 175 / 2.61 1299 / 0.35 650 / 0.71 260 / 1.76 173 / 2.64 130 / 3.53 969 / 0.47 485 / 0.95 194 / 2.36 129 / 3.54 97 / 4.73

BL-SU
LAMP QTY-LU/LP INPUT WATTS MS250/BU/PS (ENC) 1 @ 23800 292 MS400/BU/PS 1 @ 44000 452 MH400/U 1 @ 36000 458 SC @2/@4 LLF TEST # 1.6/1.5 0.57 HP-04228 1.5/1.5 0.60 HP-04205 1.5/1.5 0.57 HP-04205 ROOM WIDTH -/MOUNTING HEIGHT (above floor) 5 or more 2 1 5 or more 2 1 5 or more 2 1 ILLUMINANCE (MAINTAINED) APPROXIMATE AREA PER LUMINAIRE (SQ. FT.) / APPROXIMATE WATTS PER SQ. FT. (w/Blst. Losses) 10 fc 20 fc 50 fc 75 fc 100 fc 1143 / 0.26 572 / 0.51 229 / 1.28 152 / 1.92 n.r. / n.r. 885 / 0.33 442 / 0.66 177 / 1.65 118 / 2.48 n.r. / n.r. 667 / 0.44 333 / 0.88 133 / 2.19 89 / 3.28 n.r. / n.r. 2291 / 0.20 1146 / 0.39 458 / 0.99 305 / 1.48 229 / 1.97 1764 / 0.26 882 / 0.51 353 / 1.28 235 / 1.92 176 / 2.56 1317 / 0.34 658 / 0.69 263 / 1.72 176 / 2.57 132 / 3.43 1794 / 0.26 897 / 0.51 359 / 1.28 239 / 1.91 179 / 2.55 1382 / 0.33 691 / 0.66 276 / 1.66 184 / 2.49 138 / 3.31 1031 / 0.44 516 / 0.89 206 / 2.22 137 / 3.33 103 / 4.44

144

QUICK ESTIMATORS
SWX, LWX, MLX
To determine the number of luminaires required for a given illuminance level:

Step 1: Determine room size per column three below as 5 or more (Large
Room), 2 (Medium Room) or 1 (Small Room.

Step 2: For desired footcandle level, per room size, divide floor area of space
by Approximate Area per Luminaire from chart.

Step 3: If required, adjust result of Step 2 to whole number. Result is quantity


of luminaires required to provide approximate, average maintained illuminance selected.

SWX
LAMP QTY-LU/LP INPUT WATTS MS250/BU/PS 1 @ 23800 292 MS400/BU/PS 1 @ 44000 452 MH400/U 1 @ 36000 458 PLT42WW/4P 8 @ 3200 302 SC @2/@4 LLF TEST # 2.4/2.2 0.59 HP-08710 2.3/2.2 0.59 HP-08709 2.4/2.2 0.56 HP-06357 1.6/1.8 0.73 HP-08949 ROOM WIDTH -/MOUNTING HEIGHT (above floor) 5 or more 2 1 5 or more 2 1 5 or more 2 1 5 or more 2 1 ILLUMINANCE (MAINTAINED) APPROXIMATE AREA PER LUMINAIRE (SQ. FT.) / APPROXIMATE WATTS PER SQ. FT. (w/Blst. Losses) 10 fc 20 fc 50 fc 75 fc 100 fc 1086 / 0.27 543 / 0.54 217 / 1.34 145 / 2.02 n.r. / n.r. 696 / 0.42 348 / 0.84 139 / 2.10 93 / 3.14 n.r. / n.r. 474 / 0.62 237 / 1.23 95 / 3.08 63 / 4.62 n.r. / n.r. n.r. / n.r. 966 / 0.47 386 / 1.17 257 / 1.76 193 / 2.34 n.r. / n.r. 631 / 0.72 252 / 1.79 168 / 2.69 126 / 3.58 n.r. / n.r. 425 / 1.06 170 / 2.66 113 / 3.99 85 / 5.32 1532 / 0.30 766 / 0.60 306 / 1.49 204 / 2.24 153 / 2.99 988 / 0.46 494 / 0.93 198 / 2.32 132 / 3.48 99 / 4.64 665 / 0.69 333 / 1.38 133 / 3.44 89 / 5.16 67 / 6.88 1077 / 0.28 539 / 0.56 215 / 1.40 144 / 2.10 n.r. / n.r. 687 / 0.44 344 / 0.88 137 / 2.20 92 / 3.30 n.r. / n.r. 464 / 0.65 232 / 1.30 93 / 3.25 62 / 4.88 n.r. / n.r.

LWX
LAMP QTY-LU/LP INPUT WATTS PLT42W/4P 1 @ 3200 82 MXR150/U/MED 1 @ 12500 185 MH175/U/M 1 @ 13500 210 SC @2/@4 LLF TEST # 1.3/1.5 0.78 HP-08286 2.0/1.9 0.58 HP-08740 2.1/2.0 0.56 HP-08738 ROOM WIDTH -/MOUNTING HEIGHT (above floor) 5 or more 2 1 5 or more 2 1 5 or more 2 1 ILLUMINANCE (MAINTAINED) APPROXIMATE AREA PER LUMINAIRE (SQ. FT.) / APPROXIMATE WATTS PER SQ. FT. (w/Blst. Losses) 5 fc 10 fc 20 fc 50 fc 75 fc 597 / 0.14 299 / 0.27 149 / 0.55 75 / 1.10 n.r. / n.r. 378 / 0.22 189 / 0.43 95 / 0.87 50 / 1.65 n.r. / n.r. 259 / 0.32 129 / 0.63 65 / 1.27 35 / 2.35 n.r. / n.r. 1082 / 0.17 541 / 0.34 270 / 0.68 108 / 1.71 72 / 2.57 721 / 0.26 361 / 0.51 180 / 1.03 72 / 2.57 48 / 3.85 505 / 0.37 252 / 0.73 126 / 1.47 50 / 3.67 34 / 5.50 1134 / 0.19 567 / 0.37 284 / 0.74 113 / 1.85 76 / 2.78 756 / 0.28 378 / 0.56 189 / 1.11 76 / 2.78 50 / 4.17 529 / 0.40 265 / 0.79 132 / 1.59 53 / 3.97 35 / 5.95

MLX
LAMP QTY-LU/LP INPUT WATTS MVR175/VBU/PA 1 @ 17500 208 MS250/BU/PS 1 @ 23800 292 MH250/U 1 @ 20500 295 SC @2/@4 LLF TEST # 1.6/2.3 0.62 HP-05817 1.6/2.3 0.59 HP-05814 1.6/2.3 0.55 HP-05814 ROOM WIDTH -/MOUNTING HEIGHT (above floor) 5 or more 2 1 5 or more 2 1 5 or more 2 1 ILLUMINANCE (MAINTAINED) APPROXIMATE AREA PER LUMINAIRE (SQ. FT.) / APPROXIMATE WATTS PER SQ. FT. (w/Blst. Losses) 10 fc 20 fc 50 fc 75 fc 100 fc 834 / 0.25 417 / 0.50 167 / 1.25 111 / 1.87 n.r. / n.r. 563 / 0.37 281 / 0.74 113 / 1.85 75 / 2.77 n.r. / n.r. 390 / 0.53 195 / 1.07 78 / 2.67 52 / 4.00 n.r. / n.r. 1072 / 0.27 536 / 0.54 214 / 1.36 143 / 2.04 107 / 2.72 724 / 0.40 362 / 0.81 145 / 2.02 97 / 3.022 72 / 4.03 501 / 0.58 251 / 1.16 100 / 2.91 67 / 4.37 50 / 5.82 871 / 0.34 435 / 0.68 174 / 1.69 116 / 2.54 87 / 3.39 588 / 0.50 294 / 1.00 118 / 2.51 78 / 3.76 59 / 5.02 407 / 0.72 204 / 1.45 81 / 3.62 54 / 5.43 41 / 7.24

145

HID BALLAST ELECTRICAL DATA


METAL HALIDE
LINE VOLTS 120 208 240 277 120 277 120 208 240 277 480 120 208 240 277 480 120 208 208 277 480 120 208 240 277 120 208 240 277 480 120 208 240 277 480 120 208 240 277 480 277 120 208 240 277 480 CIRCUIT 100 WATT HX-HPF HX-HPF HX-HPF HX-HPF 150 WATT HX-HPF HX-HPF 175 WATT SUPER-CWA SUPER-CWA SUPER-CWA SUPER-CWA SUPER-CWA 200 WATT SUPER-CWA SUPER-CWA SUPER-CWA SUPER-CWA SUPER-CWA 250 WATT CWA CWA CWA CWA CWA 250 WATT SUPER-CWA SUPER-CWA SUPER-CWA SUPER-CWA 320 WATT SUPER-CWA SUPER-CWA SUPER-CWA SUPER-CWA SUPER-CWA 350 WATT SUPER-CWA SUPER-CWA SUPER-CWA SUPER-CWA SUPER-CWA 400 WATT CWA CWA CWA CWA CWA R-HPF 400 WATT SUPER-CWA SUPER-CWA SUPER-CWA SUPER-CWA SUPER-CWA TYPE START CURRENT OPERATING AMP AMP 1.2 0.8 0.6 0.6 0.9 0.4 0.7 0.8 0.6 0.6 0.2 0.8 0.4 0.4 0.3 0.2 2.4 1.4 1.2 1.0 0.6 1.9 1.1 1.0 0.9 1.8 1.0 0.9 0.8 0.4 2.2 1.3 1.1 1.0 0.6 2.7 1.6 1.4 1.2 0.7 2.1 2.8 1.6 1.5 1.3 0.8 1.1 0.7 0.6 0.5 1.6 0.7 1.8 1.0 0.9 0.8 0.4 2.1 1.2 1.0 0.9 0.5 2.6 1.5 1.4 1.1 0.6 2.5 1.5 1.3 1.1 3.3 1.9 1.6 1.4 0.8 3.4 2.0 1.7 1.5 0.9 4.1 2.3 2.0 1.7 1.0 1.7 3.8 2.2 1.9 1.6 1.0 OCC AMP 2.3 1.4 1.1 1.0 PF WATT REG VOLT REG 5% 5% 5% 5% 5% 5% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 5% 10% 10% 10% 10% 10% FUSE RATE AMP 6 4 4 3 10 4 5 3 3 3 2 6 4 3 3 2 8 5 5 3 2 8 5 5 3 8 6 5 3 3 10 7 5 5 3 10 7 5 5 3 5 10 7 5 5 3 START TEMP -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -30F / -35C -30F / -35C -30F / -35C -30F / -35C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -5F / -20C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C OCV VOLT 265 265 265 265 265 265 275 275 275 275 275 252 252 252 252 240 315 315 315 315 315 275 275 275 275 270 270 270 270 270 270 270 270 270 275 300 300 300 300 300 277 265 265 265 265 270 FREQ

Quad Quad Quad Quad Dual Dual Quad Quad Quad Quad Single Quad Quad Quad Quad Single 5-Tap 5-Tap 5-Tap 5-Tap 5-Tap Quad Quad Quad Quad Quad Quad Quad Quad Single Quad Quad Quad Quad Single 5-Tap 5-Tap 5-Tap 5-Tap 5-Tap Single Quad Quad Quad Quad Single

M90/M140 LAMP 0.90 12% 0.90 12% 0.90 12% 0.90 12% M102/M142 LAMP 0.90 12% 3.7 0.90 12% 1.6 M137/M152 (PS) LAMP 0.90 10% 1.9 0.90 10% 1.0 0.90 10% 0.9 0.90 10% 0.8 0.90 10% 0.5 M136 (PS) LAMP 0.90 10% 1.3 0.90 10% 0.8 0.90 10% 0.6 0.90 10% 0.6 0.90 10% 0.5 M58 LAMP 0.90 10% 2.0 0.90 10% 1.2 0.90 10% 1.0 0.90 10% 0.9 0.90 10% 0.5 M138/153 (PS) LAMP 0.90 10% 1.4 0.90 10% 0.8 0.90 10% 0.7 0.90 10% 0.6 M132/154 (PS) LAMP 10% 2.3 0.90 10% 1.4 0.90 10% 1.1 0.90 10% 1.0 0.90 10% 0.6 0.90 M131 (PS) LAMP 10% 2.2 0.90 10% 1.3 0.90 10% 1.1 0.90 10% 1.0 0.90 10% 0.6 0.90 M59 LAMP 0.90 10% 3.7 0.90 10% 1.8 0.90 10% 1.6 0.90 10% 1.3 0.90 10% 0.8 0.90 9% 2.1 M135/M155 (PS) LAMP 10% 2.2 0.90 10% 1.5 0.90 10% 1.1 0.90 10% 0.9 0.90 10% 0.6 0.90

60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60

146

LINE VOLTS 120 208 240 277 480 120 208 240 277 120 208 240 277 480 120 208 240 277 120 208 240 277

CIRCUIT 450 WATT SUPER-CWA SUPER-CWA SUPER-CWA SUPER-CWA SUPER-CWA 750 WATT SUPER-CWA SUPER-CWA SUPER-CWA SUPER-CWA 1000 WATT CWA CWA CWA CWA CWA 1000 WATT SUPER-CWA SUPER-CWA SUPER-CWA SUPER-CWA 175/150 WATT CWA CWA CWA CWA

TYPE

START CURRENT OPERATING AMP AMP 3.2 1.8 1.6 1.4 0.6 5.2 3.1 2.4 2.3 6.0 2.8 3.0 2.3 1.5 7.8 4.0 3.7 3.2 1.3 0.8 0.6 0.6 4.3 2.5 2.2 1.9 1.1 7.0 4.0 3.5 3.0 9.1 5.6 4.7 4.1 2.4 9.0 5.2 4.5 3.9 1.8 1.0 0.9 0.8

OCC AMP 2.2 1.3 1.1 1.0 0.7 3.8 1.9 1.9 1.7 5.2 4.3 3.1 2.6 1.6 4.5 2.7 2.3 2.2 1.8 1.0 0.9 0.8

PF M144 (PS) LAMP 0.90 0.90 0.90 0.90 0.90 M149 LAMP 0.90 0.90 0.90 0.90 M47 LAMP 0.96 0.96 0.96 0.96 0.96 M141 (PS) LAMP 0.90 0.90 0.90 0.90 M57/M107 LAMP 0.90 0.90 0.90 0.90

WATT REG 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 12% 12% 12% 12% 10% 10% 10% 10%

VOLT REG 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10%

FUSE RATE AMP 10 8 5 5 3 20 10 10 10 22 15 12 10 6 20 15 10 10 5 3 3 2

START TEMP -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -30F / -35C -30F / -35C -30F / -35C -30F / -35C -30F / -35C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C

OCV VOLT 257 257 257 257 267 340 340 340 340 426 426 426 426 426 430 430 430 430 305 305 305 305

FREQ

Quad Quad Quad Quad Single Quad Quad Quad Quad 5-Tap 5-Tap 5-Tap 5-Tap 5-Tap Quad Quad Quad Quad Quad Quad Quad Quad

60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60

147

HID BALLAST ELECTRICAL DATA


HIGH PRESSURE SODIUM
LINE VOLTS 120 120 277 120 120 277 120 208 240 277 120 120 277 120 208 240 277 480 240 480 120 120 208 240 277 480 120 120 240 480 120 208 240 277 480 240 480 120 208 240 277 480 480 120 208 240 277 480 CIRCUIT 35 WATT R-HPF 50 WATT HX-HPF HX-HPF R-HPF 70 WATT CWA CWA HX-HPF HX-HPF HX-HPF HX-HPF R-HPF 100 WATT CWA CWA HX-HPF HX-HPF HX-HPF HX-HPF HX-HPF REGULATED LAG REGULATED LAG R-HPF 150 WATT HX-HPF HX-HPF HX-HPF HX-HPF HX-HPF R-HPF 200 WATT REGULATED LAG REGULATED LAG REGULATED LAG 250 WATT CWA CWA CWA CWA CWA REGULATED LAG REGULATED LAG 400 WATT CWA CWA CWA CWA CWA REGULATED LAG 1000 WATT CWA CWA CWA CWA CWA TYPE START CURRENT OPERATING AMP AMPS 0.8 0.6 0.3 0.9 0.9 0.4 0.8 0.4 0.4 0.3 0.9 0.8 0.3 1.3 0.8 0.6 0.6 0.3 0.3 0.1 1.5 2.0 1.1 1.0 0.9 0.5 2.3 0.8 0.4 0.2 1.4 0.7 0.7 0.6 0.4 0.4 0.2 3.5 2.0 1.7 1.5 0.9 0.5 7.8 4.4 3.8 3.3 1.9 0.4 0.6 0.3 0.6 0.9 0.4 0.8 0.5 0.4 0.3 0.8 1.1 0.5 1.1 0.7 0.6 0.5 0.3 0.6 0.3 1.0 1.6 0.9 0.8 0.7 0.4 1.5 2.2 1.1 0.6 2.7 1.5 1.3 1.2 0.7 1.4 0.7 3.9 2.2 1.9 1.7 1.0 1.0 9.3 5.3 4.7 4.0 2.3 OCC AMP 0.6 0.6 0.4 0.9 0.2 0.1 1.5 0.9 0.8 0.6 1.3 0.6 0.3 2.2 1.3 1.1 0.9 0.6 0.5 0.3 1.8 2.8 1.6 1.4 1.3 0.7 2.3 1.5 0.8 0.4 1.8 1.0 0.9 0.9 0.4 0.7 0.3 1.8 1.0 0.9 0.8 0.4 0.6 3.9 2.2 2.0 1.7 1.0 PF WATT REG VOLT FUSE RATE REG AMP 5% 5% 5% 5% 10% 10% 5% 5% 5% 5% 5% 10% 10% 5% 5% 5% 5% 5% 10% 10% 5% 5% 5% 5% 5% 5% 5% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 2 3 1 3 3 1 5 3 2 2 3 3 2 7 5 3 3 3 1.5 1 5 10 5 5 4 2 8 6 3 2 10 4 4 3 2 5 3 10 6 5 5 3 5 25 15 12 10 6 START TEMP -40F / -40C -20F / -30C -20F / -30C -40F / -40C -40F / -40C -40F / -40C -40F / -40C -40F / -40C -40F / -40C -40F / -40C -40F / -40C -40F / -40C -40F / -40C -40F / -40C -40F / -40C -40F / -40C -40F / -40C -40F / -40C -40F / -40C -40F / -40C -40F / -40C -40F / -40C -40F / -40C -40F / -40C -40F / -40C -40F / -40C -40F / -40C -40F / -40C -40F / -40C -40F / -40C -40F / -40C -40F / -40C -40F / -40C -40F / -40C -40F / -40C -40F / -40C -40F / -40C -40F / -40C -40F / -40C -40F / -40C -40F / -40C -40F / -40C -40F / -40C -40F / -40C -40F / -40C -40F / -40C -40F / -40C -40F / -40C OCV VOLT 120 125 125 120 105 105 120 120 120 120 120 115 115 120 120 120 120 120 115 115 120 120 120 120 120 120 120 225 225 225 185 185 185 185 185 220 220 195 195 195 195 195 215 437 437 437 437 437 FREQ

Single Dual Dual Single Dual Dual Quad Quad Quad Quad Single Single Single Quad Quad Quad Quad Single Dual Dual Single Quad Quad Quad Quad Single Single Dual Dual Dual 5-Tap 5-Tap 5-Tap 5-Tap 5-Tap Dual Dual 5-Tap 5-Tap 5-Tap 5-Tap 5-Tap Single 5-Tap 5-Tap 5-Tap 5-Tap 5-Tap

S76 LAMP 0.90 Within Trapezoid S68 LAMP 0.90 Within Trapezoid 0.90 Within Trapezoid 0.90 Within Trapezoid S62 LAMP 0.90 Within Trapezoid 0.90 Within Trapezoid 0.90 Within Trapezoid 0.90 Within Trapezoid 0.90 Within Trapezoid 0.90 Within Trapezoid 0.90 Within Trapezoid S54 LAMP 0.90 Within Trapezoid 0.90 Within Trapezoid 0.90 Within Trapezoid 0.90 Within Trapezoid 0.90 Within Trapezoid 0.90 Within Trapezoid 0.90 Within Trapezoid 6% 0.90 6% 0.90 0.90 Within Trapezoid S55 LAMP 0.90 Within Trapezoid 0.90 Within Trapezoid 0.90 Within Trapezoid 0.90 Within Trapezoid 0.90 Within Trapezoid 0.90 Within Trapezoid S66 LAMP 0.90 Within Trapezoid 0.90 Within Trapezoid 0.90 Within Trapezoid S50 LAMP 10% 0.93 10% 0.93 10% 0.93 10% 0.93 10% 0.93 0.90 4% 0.90 4% S51 LAMP 10% 0.98 10% 0.98 10% 0.98 10% 0.98 10% 0.98 0.90 Within Trapezoid S52 LAMP 0.98 Within Trapezoid 0.98 Within Trapezoid 0.98 Within Trapezoid 0.98 Within Trapezoid 0.98 Within Trapezoid

60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60

148

HID BALLAST ELECTRICAL DATA


MERCURY VAPOR
LINE VOLTS 120 208 277 480 120 208 240 277 480 120 208 240 277 480 120 208 240 277 480 120 208 240 277 480 CIRCUIT 100 WATT CWA CWA CWA CWA 175 WATT CWA CWA CWA CWA CWA 250 WATT CWA CWA CWA CWA CWA 400 WATT CWA CWA CWA CWA CWA 1000 WATT CWA CWA CWA CWA CWA TYPE START CURRENT OPERATING AMP AMP 1.0 0.6 0.4 0.3 1.6 0.9 0.8 0.7 0.4 2.5 1.5 1.3 1.1 0.6 3.2 2.0 1.7 1.5 0.9 8.0 4.6 4.0 3.5 1.0 0.6 0.4 0.3 1.9 1.1 1.0 0.8 0.4 2.5 1.5 1.3 1.1 0.6 3.9 2.2 2.0 1.7 1.0 9.8 5.6 4.9 4.3 OCC AMP H38 LAMP 0.5 0.3 0.2 0.2 H39 LAMP 1.0 0.6 0.5 0.4 0.3 H37 LAMP 0.7 0.4 0.3 0.3 0.3 H33 LAMP 0.8 0.6 0.5 0.4 0.3 H36 LAMP 1.8 1.1 0.9 0.8 PF WATT REG 5% 5% 5% 5% 10% 10% 10% 10% 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% 10% 10% 10% 10% 10% VOLT REG 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% FUSE RATE AMP 3 2 2 1 5 3 3 2 2 8 5 5 3 2 10 8 5 5 5 20 15 10 10 START TEMP -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C -20F / -30C OCV VOLT 250 250 250 250 215 215 215 215 240 250 250 250 250 250 245 245 245 245 245 425 425 425 425 425 FREQ

Quad Quad Quad Single Quad Quad Quad Quad Single Quad Quad Quad Quad Single Quad Quad Quad Quad Single Quad Quad Quad Quad Single

0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90

60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60

149

TROUBLESHOOTING GUIDE
HID The guide is prepared to assist electricians with normal routine maintenance and to help them understand the operation of different lamp sources and electrical systems. Most require a starting voltage that is higher than the line voltage. BALLASTS All HID light sources require some form of ballast because:

Caution: High voltages, currents, and temperatures are requires to operate gas discharge lamps. Shock and burn hazards exist, and testing or evaluating fixtures or components should be done by qualified individuals only.

They all have a characteristic known as negative resistance. This means that once the arc is initiated, the lamps resistance continually decreases as current increases. For all practical purposes, the lamp becomes a short circuit. The ballast limits and controls the current wave form through the lamp.

LIGHT SOURCES: Fluorescent Mercury Vapor (MV) Metal Halide (MH) They provide voltage transformation to allow the use of many line voltages.

High Pressure Sodium (HPS) There are many different types of ballasts used with different lamps. Within a LAMPS Fluorescent lamps come in many sizes, shapes and colors. This lamp source can provide numerous advantages, depending on the needs and requirements of end users. These lamps are generally used when low mounting heights and quiet operations are required. Note that many new, more efficient lamps and electronic ballasts offer the customer many energy saving opportunities. CAPACITORS Capacitors are used for power factor correction or as current regulation devices, which provide the control necessary to ensure proper lamp and ballast operaMercury Vapor lamps were the first to be developed in the family of high intensity discharge (HID) lamps. Their advantage is that they offer long life. Their disadvantages are poor color rendition, poor lumen maintenance and low efficiency. tion. Different wattages, voltages, and ballast types require a variety of different capacitors. The ballast ID label specifies the microfarad and voltage rating required for proper operation. If the capacitor is incorrectly wired, improper operation of the fixture as well as other component failures could result. lamp type, ballasts vary in lamp operating wattage and regulation caused by changes in line voltage and lamp voltage. Better regulation and control normally result in higher initial cost, but may greatly improve operating characteristics and overall performance.

MH lamps are similar to MV lamps in design and operation. Their lumen output is double that of MV lamps of the same wattage. MH lamps are used in installations that require high efficiency and white light. Lamp life historically has been less than MV and HPS, however, new MH systems are now changing this by providing excellent life, lumen maintenance and color control.

IGNITORS/STARTER These devices are utilized to provide the proper voltage and energy to start the lamp. They are predominantly used with HPS lamps as well as some Metal Halide and Fluorescent systems.

HPS lamps offer long life and more lumens per watt than MV and MH sources. HPS lamps emit a pale amber color compared to other whiter light sources. Energy savings is the main HPS advantage. New high-xenon HPS lamps offer even higher LPW, longer life and improved lumen maintenance.

150

ELECTRICAL TESTING PROCEDURES

C. CAPACITORS Testing Capacitors may be accomplished by:

Caution: High voltages, currents, and temperature are required to operate lamps. Therefore, shock and burn hazards exist, and testing or evaluating fixtures or components should be done only by qualified individuals.

VISUAL INSPECTION FOR SWOLLEN CAPACITORS.

If the capacitor is swollen or

bulged on the sides or top where the terminals are located, remove and A. TESTING LAMPS The easiest method of troubleshooting a fixture is to try a known good lamp in the inoperative fixture. If the lamp being replaced exhibits any of the following conditions, replace with a new lamp.
1 SODIUM LEAKER LAMP - will be a brown/golden coating on the inside of the 3 USING AN OHMMETER TO CHECK CAPACITORS: 2 VERIFY THE CORRECT MICROFARAD RATING as specified on the ballast I.D. label.

replace with a new one.

discharge capacitor by shorting

lamp envelope other than at the base of the lamp.


2 AMALGAM LEAKER LAMP

between the terminals disconnect capacitor from circuit remove bleed resistor

- the lamp envelope will have a smoke bronze

appearance on the inside of the envelope.


3 FAULTY BASE TO LAMP ENVELOPE SEAL

- a white powdery substance will


4 SET OHMMETER TO HIGHEST RESISTANCE SCALE

appear at the base of the lamp where oxygen has leaked inside the lamp.
4 END OF LAMP LIFE

and connect leads to capaci-

tor terminals. - the arc tube will be black on both ends or the entire If resistance starts low and gradually increases, the capacitor is good. If resistance starts low and doesnt increase, the capacitor is shorted and should be replaced.

length of the arc tube will be black.

BROKEN WELDS OR ARC TUBE SUPPORT BRACKETS - mechanical breaks occasion-

If resistance is high and remains relatively the same, the capacitor is open and should be replaced.

ally occur due to rough handling or internal thermal stresses. Broken welds in evacuated (HPS) lamps can also create a problem known as vacuum switching. Extremely high voltage surges occur in the lamp circuit if the weld opens while the lamp is operation. Secondary coil burnout, ignitor arcing and socket arcing can occur. Rewelding may occur and the lamp may

D. BALLAST
SAFETY

Safety measures should always be taken when troubleshooting HID

systems. Most procedures will require that power be applied when electrical measurements are made. Wearing gloves and eye protection is a good practice when doing electrical measurements on HID systems.

appear to be satisfactory; however, if left in operation, failure of the ballast


and/or ignitors is likely.

B. IGNITORS/STARTERS The starter provides the necessary voltage and energy required to initiate the arc in the lamp. The easiest way to check the ignitor on 35W to 150W HPS units is to install a 120V incandescent lamp in the fixture. If the incandescent lamp operates but a known good HPS lamp will not ignite, replace starter. In 200W to 1000W HPS fixtures, install a mercury lamp of similar wattage. If the mercury lamp lights and the HPS lamp will not, replace the starter.

INSTRUMENTS AND TEST EQUIPMENT FOR TROUBLESHOOTING

Only the input to HID

lighting systems is a sine wave. Once the voltage and current is processed through the ballast and lamp, it is changed and is no longer a perfect sine wave. As a result of this transformation, only TRUE RMS volt and amp meters will give proper readings. TRUE RMS volt clamp-on current meters are also available and are most convenient when reading lamp current.

There are many brands of test meters available. Some indicate RMS and Do not operate incandescent or mercury lamps used to check the started for extended periods of time (more than 1/2 hour). some indicate TRUE RMS on the meter. They are not the same. Only those that have TRUE RMS will read non-sinusoidal waveforms accurately. The RMS meters will give readings 10 to 20% low depending on the shape of the voltage or current waveform.

151

TROUBLESHOOTING GUIDE
Some of these instruments will also read capacitance directly when connected to a disconnected, discharged capacitor.
ELECTRONIC BALLASTS

cont
Lamps operated by electronic ballasts will not

exhibit the above metal halide symptoms at end-of-life. Because electronic ballasts have sensing circuits to detect lamp end-of-life, a ballast

There is no field-usable meter to test ignitors.

connected to an inoperative lamp will likely be in a shut down mode or will not start. When servicing the fixture, always disconnect or shut off

TROUBLESHOOTING PROCEDURES

At times when an HID lighting system

power to that fixture for safety. When the power is cycled off and then on, the lamp may restart and later go off and stay off. Visual indications of the lamp may be the same. However, the true and sure test is to replace the lamp. After the lamp is replaced, the POWER TO THE BALLAST MUST BE CYCLED OFF AND BACK ON FOR THE BALLAST TO RESTART THE LAMP.

becomes inoperative, a complex and thorough troubleshooting procedure may prove overly time consuming. A simple series of checks can decrease this time considerably; a simple check of circuit breakers and power switches when a bank of fixtures becomes inoperative or a visual check or replacement of a lamp when an individual fixture becomes inoperative. At other times, isolated inoperative fixtures may require systematic procedures to determine the cause of failure.

NOTE: When the power is cycled off and back on via a circuit breaker switch, other fixtures on the same circuit will extinguish and not come back on until the lamps cool. The e nergized ballast will continue to

NORMAL END OF LAMP LIFE

Most fixtures fail to light properly due to lamps that

produce high voltage starting pulses for a specified period, usually between 10 and 30 minutes, depending on the ballast module, allowing enough time for the hot lamp to cool.

have reached end-of-life. Normal end of light indications are low light output, failure to start or lamps cycling off and on. These problems can be eliminated by replacing the lamp. Since many HID fixtures are not easily serviced due to their mounting height, the technicians should take a replacement lamp when going up a ladder or on a lift.

It is assumed at this point in the troubleshooting procedure that the lamp has been replaced with a known good lamp. If there is any doubt about a replacement lamp, it should be tested in an operational, good fixture.

Mercury and metal halide lamps at end-of-life are characterized by low light output and/or intermittent starting. It is possible for metal halide pulse start lamps to cycle off and on like high pressure sodium lamps at end-of-life. Visual indications include blackening at the ends of the arc tube and electrode deterioration, but these are not conclusive. The sure test is to replace the lamp. Because troubleshooting can be time consuming, power to the fixture should be verified at the fixture. Photo cells, circuit breakers, and switched should all be checked. The following flow charts are designed to minimize troubleshoot time and, if possible, eliminate taking the ballast housing apart.

High pressure sodium lamps will tend to cycle at the end-of-life. After start-up, they will cycle off and on as the aged lamp requires more voltage to stabilize and operate the arc than the ballast is designed to provide.

Visual indications include general blackening at the ends of the arc tube. The lamp may also exhibit a brownish color (sodium deposit) on the outer glass envelope. The sure test is to replace the lamp.

Low pressure sodium lamps retain their light output but starting becomes intermittent and then impossible. Visual signs include some blackening of the ends of the arc tube. The sure test is to replace the lamp.

152

Troubleshooting HID Fixtures


Lamp will not start: STEP 1
Replace Lamp with known good lamp Lamp Starts (bad lamp) Check Breaker, Fuse, Photocell Measure line voltage at ballast input and verify conformance with ballast label

Lamp will not start: STEP 2


Open Circuit Voltage measurement out of spec

Visually verify proper combination of lamp, ballast, capacitor, ignitor and associated wiring Correct if not all compatible Inspect ballast capacitor, ignitor and lamp socket for physical damage or signs of failure Replace all damaged components Measure open circuit voltage at lamp socket

If not conforming: Electrical exist outside of fixture

If conforming: Perform lighting component tests STEP 3

Recheck circuit wiring, fuses, breakers, photocells, switches, etc. CAUTION! If ignitor is present it must be disabled before performing test!

If out of spec: continue testing, move on to STEP 2

If in spec: perform tests for lighting components, move to STEP 3

Lamp Cycles
Replace Lamp with a new or known operative lamp

Lamp will not start: STEP 3


Lighting System Component Testing

Visually inspect and verify use of proper combination of lamp, ballast and capacitor

Replace any apparently damaged ballast, capacitor or lamp socket Perform ignitor test or replace ignitor Perform capacitor tests Measure short circuit lamp current

Check fixture supply voltage per ballast or fixture label

Replace defective capacitor (shorted open or wrong or changed value)

If out of Spec: replace inoperative ballast (also replace capacitors, ignitor (where used) to assure proper performance

If out of spec: Problem is outside of the fixture

If in spec: Go to Step 3

153

TROUBLESHOOTING GUIDE
MEASURING LINE VOLTAGE

cont

Measure the line voltage at input to the fixture to

Measure the voltage on both sides of the capacitor. If the voltage exists on the ballast side but not on the lamp side, change the capacitor and re-measure the open circuit voltage at the lamp socket. If there is still no voltage disconnect the lamp socket from the ballast and measure open circuit voltage again. Once a voltage is measured test the lamp socket for shorts with an ohm-meter or replace the lamp socket. An ohm-meter test is not conclusive as the test is at

determine if the power supply conforms to the requirements of the lighting system. For constant wattage ballasts (CWA, CWI), the measured line voltage should be within 10% of the nameplate rating. For reactor (R) or high reactance (HX) ballasts, the line voltage should be within 5% of the nameplate rating.

If the measured line voltage does not conform to the requirements of the lighting system, as specified on the ballast or fixture nameplate, the electrical problem exists outside of the fixture which can result in non-starting or improper lamp operation.

low voltage and the failure may be due to the open-circuit voltage.

Open Circuit Voltage Test


Input Output Cap

Check breakers, fixture fuses, photocells, and switches when no voltage reading can be measures. High, low, or variable voltage readings may be due to load fluctuations. The supply voltage should be measured with the defective fixture connected to the line and power applied to help determine possible voltage supply problems.

Line

V1 BALLAST Lamp Socket V2

Open Circuit Voltage Test Limits


Lamp Wattage 50 75 100 125 175 250 400 2-400 (Series) 1000 35/39 50 70 70 70 100 150 150 175 175 PS 200 PS 250 250 250 PS 320 PS 350 PS 400 400 PS 400 PS 2-400 (ILO) 450 PS 750 PS 875 PS 1000 1000 PS 1500 1650 2000 ANSI Number H46 H43 H38 H42 H39 H37 H33 2-H33 H36 M130 M110 or M148 M85 M98 or M143 M139 M90 or M140 M81 M102 or M142 M57 or M107 M136 M136 M58 M80 M138 or M153 M132 or M154 M131 M59 M135 or M155 M128 2-M59 M144 M149 M166 M47 M141 M48 M112 M134 RMS Voltage* 215-270 220-275 225-285 230-290 200-290 210-295 210-285 445-545 385-465 205-290 235-300 200-270 205-290 220-280 210-315 215-265 180-300 275-355 250-340 215-330 270-345 215-265 245-330 240-310 240-315 250-360 235-340 285-345 300-360 235-340 305-390 375-455 385-485 370-475 405-530 420-510 405-495

If the proper input voltage is measured, most HID fixture problems can be
mercury ballasts metal halide ballasts

determined by measuring open circuit voltage and short circuit current.

MEASURING OPEN CIRCUIT VOLTAGE

To determine if the ballast is supplying proper

starting voltage to the lamp, an open circuit voltage test is required. The proper test procedure is: 1 Measure input voltage (V1) to verify rated input voltage is being applied to the ballast. 2 If the ballast has an ignitor (HPS, low wattage MH - 35W to 150W - or pulse start MH), the ignitor must be disconnected or disabled with a capacitor (1000 pF or larger) across the voltmeter input to protect the meter from the hight voltage ignitor pulse. Some ballasts have an integral or built-in ignitor. If you are not sure if an ignitor is used, put a capacitor across the meter for all open circuit voltage measurements. 3 With the lamp out of the socket and the voltage applied to the ballast or the proper tap of the ballast with multiple voltage inputs, read the voltage (V2) between the lamp socket center pin and shell. Some lamp socket shells are split. Make sure connection is being made to the active part. The reading must be within test limits shown in the table below. Open circuit voltage must be measured with a TRUE RMS voltmeter to provide an accurate reading. 4 Constant wattage (CWA, CWI) ballasts have a capacitor in series with the lamp. If the capacitor is open there will be no open circuit voltage.

154

Open Circuit Voltage Test Limits


Lamp Wattage 35 50 70 100 150 150 200 250 310 400 430 600 750 1000 18 35 55 90 180 ANSI Number S76 S68 S62 S54 S55 S56 S66 S50 S67 S54 SonAgro S145 S106 S111 S52 L69 L70 L71 L72 L74 RMS Voltage* 114-126 114-140 100-135 95-135 100-135 165-250 205-260 170-255 155-255 170-255 180-220 200-265 200-245 395-485 280-330 430-530 430-550 430-575 610-760
Input A1

Short Circuit Current Test


Output Cap Line V1 BALLAST Common Lamp Socket A2

high pressure sodium ballasts*

Short Circuit Lamp Current Test Limits


Lamp Wattage 50 75 100 125 175 250 400 2-400 (Series) 1000 25/39 50 70 70 70 100 150 150 175 175 PS 200 PS 250 250 250 PS 320 PS 350 PS 400 400 PS 400 PS 2-400 (ILO) 450 PS 750 PS 875 PS 1000 1000 PS 1500 1650 2000 35 50 70 100 150 150 200 250 310 400 430 600 750 1000 18 35 55 90 180 ANSI Number H46 H43 H38 H42 H39 H37 H33 2-H33 H36 M130 M110 or M148 M85 M98 or M143 M139 M90 or M140 M81 M102 or M142 M57 or M107 M136 M136 M58 M80 M138 or M153 M132 or M154 M131 M59 M135 or M155 M128 2-M59 M144 M149 M166 M47 M141 M48 M112 M134 S76 S68 S62 S54 S55 S56 S66 S50 S67 S54 SonAgro S145 S106 S111 S52 L69 L70 L71 L72 L74 Secondary Short Circuit Current 0.75-1.60 0.85-1.50 1.15-2.00 1.60-2.60 1.90-3.30 2.60-5.00 4.55-7.10 4.40-5.40 5.50-6.70 0.40-0.80 0.65-0.95 1.10-1.40 0.70-1.25 1.05-1.40 1.00-1.65 2.10-3.00 1.60-2.90 1.50-2.00 1.60-1.96 1.80-2.70 2.00-3.00 3.20-4.00 2.35-3.05 2.90-3.70 3.25-4.40 3.25-4.60 3.25-4.60 3.30-4.05 3.90-4.80 3.85-5.10 4.90-6.00 4.45-5.40 4.70-6.40 4.60-6.90 7.00-10.50 7.80-9.60 9.80-12.00 0.90-1.40 1.30-2.20 1.70-2.90 2.40-3.60 3.50-5.50 2.20-3.80 2.50-3.85 3.15-5.30 4.10-6.30 4.90-7.50 6.00-7.40 6.85-10.50 9.20-11.70 6.40-7.80 0.30-0.40 0.50-0.70 0.50-0.70 0.90-1.12 0.90-1.20

* Always disconnect the ignitor where equipped (typically used with metal halide <150W, pulse start metal halide, and high pressure sodium) before measuring the output voltage of ballasts. High voltage starting pulses can damage commonly used multi-meters.

low pressure sodium ballasts

As an alternative, this test may be performed by screwing an adapter into the lamp socket for easy access. Some lamp sockets have a split shell and an adapter assures good electrical connection.

SHORT CIRCUIT LAMP CURRENT TEST

Do not be concerned about momentarily

shorting a magnetic HID ballast output. They will not instantly burn up. An HID ballast is designed to limit current at the specified value range.

To assure that the ballast is delivering the proper current under lamp starting conditions, a measurement may be taken by connecting an ammeter between the lamp socket center pin and the socket shell with rated voltage applied to the ballast. If available, a lamp socket adapter may be used as described in the open circuit voltage test.

2 Measure current with ammeter at A1 and A2 as shown in the diagram right. 3 Readings must be withing test limits shown right.

A clamp-on TRUE RMS ammeter may also be used to perform this test by placing an 18 gauge wire between the lamp and common leads of the ballast. When using a clamp-on ammeter for this measurement, be certain the meter is not near the ballast magnetic field or any steel object that may affect the reading.

constant wattage circuits. A shorted capacitor will result in high short circuit current, while an open capacitor or low value capacitor will result in no or low short circuit current.

low pressure sodium ballasts

The short circuit current test will also determine a defective capacitor in

high pressure sodium ballasts

1 Energize ballast with proper rated input voltage.

metal halide ballasts

mercury ballasts

155

TROUBLESHOOTING GUIDE
CAPACITOR TESTING AND BALLAT PERFORMANCE

cont

High Reactance (HX) Type Ballast


between Common & Capacitor leads
LINE V LAMP CAP

1 Disconnect the capacitor from the circuit and discharge it by shorting the terminals or wires together. 2 Check the capacitor with an ohmeter set to the highest resistance scale: If the meter indicates a very low resistance then gradually increases, the capacitor does not require replacement; If the meter indicates a very high initial resistance that does not change, it is open and should be replaced; If the meter indicates a very low resistance that does not increase, the capacitor is shorted and should be replaced.

COM

CAP

C
COM

LAMP

COM

Reactor Ballast
between Line & Lamp leads
LINE V LAMP

The ohmeter method of testing capacitors will only determine open or shorted capacitors. The capacitance value can be tested by many available portable TRUE RMS meters having that capability, though a test using a dedicated capacitance meter is more conclusive.

C
LAMP COM

The capacitance value will affect lamp performance of Constant Wattage ballasts in ways that cannot be determined by the ohmeter method. A capacitor may look good visually, but should be tested for capacitance value or replaced.

CONTINUITY OF SECONDARY COIL

1 Disconnect the ballast from power source and discharge the capacitor by shorting its terminals or wires together.

The capacitor in a reactor or high reactance ballast circuits will only affect the ballast power factor and not ballast operation. Capacitor failure in these circuits will cause lline supply current changes possibly causing circuit breakers to activate or fixture fuse failures.

2 Check for continuity of ballast secondary coil between lamp and common leads as shown below.

Constant Wattage (CWA, CWI) Type Ballast no ignitor


between Common & Capacitor Leads (CWA shown)
BALLAST CONTINUITY CHECKS LINE V

CONTINUITY OF PRIMARY COIL

1 Disconnect the ballast from power source and discharge the capacitor by shorting its terminals or wires together. 2 Check for continuity of ballast primary coil between the voltage input leads as shown below.

C
COM

CAP

LAMP

COM

Constant Wattage (CWA, CWI) Type Ballast


between Common & Line leads (CWA shown)
LINE V Cap

High Reactance (HX) Type Ballast


between Common & Lamp leads
LINE V LAMP

C
CAP LAMP COM COM

LAMP

COM

COM

156

Constant Wattage CWA Type Ballasts


where ingitors are used
LINE V LINE V LINE V LINE V CAP COM CAP COM X3 X1 IGNITOR X2

PROBABLE CAUSES OF SHORTED OR OPEN CAPACITORS

1 Normal ballast end-of-life failure.


LAMP

2 Overheated due to heat in the fixture or ambient temperature. 3 Capacitor mounted too close to ballast. 4 Incorrect voltage or capacitor value for ballast.
LAMP

5 Mechanical damage such as over-tightened capacitor clamp.

ELECTRONIC HID BALLASTS

Electronic HID ballasts present special

troubleshooting challenges. The previously discussed procedures cannot be

Constant Wattage CWI Type Ballast


where ignitors are used
LINE V LINE V LINE V X1 X3 IGNITOR LAMP

used to test electronic HID circuits. Electronic integrated circuit control limits reliable testing that can be performed in the field.

An energized electronic HID ballast will attempt lamp ignition by producing high voltage pulses for a specified time period, usually between 10 and 30
LAMP

C
COM CAP CAP

X2

minutes. Consult the ballast label for specific times. Unlike magnetic HID ballasts, momentary shorting either output lead of an electronic HID

LAMP 2

ballast to groud or each other will render the ballast permanently inoperable.

IGNITOR TESTING

Ignitors are used as a lamp starting aid with all high pressure Verify that there is a voltage at the input of the fixture and the ballast before proceeding with the procedures of the following flow chart.

sodium, low wattage metal halide, and pulse start lamps.

Measurement of the starting pulse characteristics of an ignitor is beyond the capability of instruments available in the field. In laboratory tests, an oscilloscope equipped with a high voltage probe is used to measure pulse height and width. In the field, some simple tests may be performed to determine if the ignitor is operable. It is first assumed that the lamp has already been replaced with a known operable lamp.

Lamp will not start or cycles off after lighting


Remove power from fixture (turn off switch or circuit breaker or disconnect)

1 Replace the ignitor with a known operable ignitor. If the lamp starts, the previous ignitor was either mis-wired or inoperative. 2 If the lamp does not light, check the open circuit voltage and short circuit secondary current or refer to Flow Chart Step 3 on page 197. Replace lamp with a new or known operative lamp

FURTHER MAGNETIC BALLAST CHECKS

PROBABLE CAUSES OF INOPERABLE BALLASTS

If the lamp lights: Defective lamp

Restore power to the fixture

1 Normal ballast end-of-life failure. 2 Operating incorrect lamps. Use of higher or lower wattage lamps than rated for the ballast my cause premature ballast end-of-life. 3 Overheating due to heat from the fixture or high ambient temperatures causing the ballast temperature to exceed the specified temperature. 4 Voltage surge from lightening or power source malfunction. 5 Mis-wired, pinched, or shorted wires. 6 Shorted or open capacitor. 7 Incorrect capacitor for the ballast. 8 Capacitor not connected to the ballast correctly.
* NOTE: After lamp extinguishes or is replaced, fixture power must be removed and restored to reset the electronics. Electronic ballasts are designed to shut down (remove power to the lamp) when irregularity occurs in applied power or a lamp fails to operate within specificaitons..

If lamp does not light: Check lamp socket and replace if defective or replace ballast

157

PHOTOMETRICS
3 DIMENSIONAL LIGHTING
Superwatt For complete spacing-to-mounting height ratios, visit our web site at www.hubbell-ltg.com
PHOTOMETRIC REPORT CAT. NO.: SWx-175E-x1ASx
155 135 125 115 105

CANDELA DISTRIBUTION
0 5 15 25 35 45 55 65 75 85 90 95 105 115 125 135 145 155 165 175 180 1670 1595 1577 1621 1851 3324 2961 1585 1118 825 1053 1704 1722 620 331 253 101 0 0 0 0

PHOTOMETRIC REPORT CAT. NO.: SWx-250H-x1ASx


155 135 125 115 105

CANDELA DISTRIBUTION
0 5 15 25 35 45 55 65 75 85 90 95 105 115 125 135 145 155 165 175 180 2011 1901 1834 1870 2348 4005 3559 1917 1288 897 1179 1896 1934 662 360 266 92 0 0 0 0

PHOTOMETRIC REPORT CAT. NO.: SWx-400H-x1ASx


155 135 125 115 105

CANDELA DISTRIBUTION
0 5 15 25 35 45 55 65 75 85 90 95 105 115 125 135 145 155 165 175 180 3622 3471 3340 3417 4283 7161 6318 3582 2386 1793 2385 3475 3387 1215 662 478 167 0 0 0 0

95

95

95

V E R T I C A L LY

V E R T I C A L LY

600 900 0 120 150 0


65 75

800 120 1 0

400 210 0 0 0 0

75

75

600 200 0 0 0 0

280

65

65

0 180 210 0
55

350

240

420

55

240

0 0
25 35 45

280

55

490

0 0
25 35 45

270
5 15

320

560
5 15

15 TEST NO.: LUMINAIRE:

25

35

45

TEST NO.: LUMINAIRE:

HP-06627 SUPERWATT Reflective Material: STEEL Finish: WHITE PAINT Closure: PRISM. UVA825 HID ONE MXR175/BU/E 17100 LUMENS 210 WATTS

ZONAL LUMEN SUMMARY


DEG ZONE 0-30 0-40 0-60 0-90 90-120 90-180 0-180 LUMENS 1352 2572 7657 11386 4151 4706 16092 % LAMP 7.9 15.0 44.8 66.6 24.3 27.5 94.1 % FIXT 8.4 16.0 47.6 70.8 25.8 29.2 100.0

HP-06359 SUPERWATT Reflective Material: STEEL Finish: WHITE PAINT Closure: PRISM. UVA-825 HID ONE MVR-250/U 20500 LUMENS 285 WATTS

ZONAL LUMEN SUMMARY


DEG ZONE 0-30 0-40 0-60 0-90 90-120 90-180 0-180 LUMENS 1571 3102 9255 13593 4602 5190 18783 % LAMP 7.7 15.1 45.1 66.3 22.4 25.3 91.6 % FIXT 8.4 16.5 49.3 72.4 24.5 27.6 100.0

TEST NO.: LUMINAIRE:

HP-06357 SUPERWATT Reflective Material: STEEL Finish: WHITE PAINT Closure: PRISM. UVA-825 HID ONE MVR-400/U 36000 LUMENS 460 WATTS

V E R T I C A L LY
DEG ZONE 0-30 0-40 0-60 0-90 90-120 90-180 0-180

85

85

85

ZONAL LUMEN SUMMARY


LUMENS 2867 5665 16538 24797 8380 9446 34243 % LAMP 8.0 15.7 45.9 68.9 23.3 26.2 95.1 % FIXT 8.4 16.5 48.3 72.4 24.5 27.6 100.0

LAMP(S): EACH RATED: LINE POWER:

TOTAL LUMINAIRE EFFICIENCY: 94.1% TOTAL REFLECTANCE OF PAINT: 91.7% SHIELDING ANGLE IN DEGREES: PARALLEL 0 NORMAL 0

SPACING CRITERION
0-DEG 2.4 90-DEG 2.4 BTWN 4 2.2

LAMP(S): EACH RATED: LINE POWER:

LAMP(S): EACH RATED: LINE POWER:

SPACING CRITERION
0-DEG 2.4 90-DEG 2.4 BTWN 4 2.2

TOTAL LUMINAIRE EFFICIENCY: 91.6% TOTAL REFLECTANCE OF PAINT: 91.7% SHIELDING ANGLE IN DEGREES: PARALLEL 0 NORMAL 0

TOTAL LUMINAIRE EFFICIENCY: 95.1% TOTAL REFLECTANCE OF PAINT: 91.7% SHIELDING ANGLE IN DEGREES: PARALLEL 0 NORMAL 0

SPACING CRITERION
0-DEG 2.4 90-DEG 2.4 BTWN 4 2.2

COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC RW 0 1 2 3 4 5 6 7 8 9 10 80 70 106 95 85 77 70 63 58 52 48 44 40 50 106 89 77 67 58 50 44 39 34 31 27 30 106 85 70 59 49 42 35 30 26 22 19 10 106 80 64 52 42 35 29 24 20 17 14 70 101 89 80 72 65 59 54 49 45 41 37 70 50 30 101 101 84 80 73 66 63 56 55 47 48 40 42 34 37 29 32 25 29 21 25 18 10 101 76 61 50 41 33 28 23 19 16 13 50 90 75 65 56 49 42 37 33 29 26 22 50 30 90 72 60 50 42 36 30 26 22 19 16 10 90 69 55 45 37 30 25 21 17 15 12 50 80 67 57 50 43 38 33 29 25 23 20 30 30 80 64 53 45 38 32 27 23 20 17 14 10 80 62 50 41 33 28 23 19 15 13 10 50 71 59 51 44 38 33 29 25 22 20 17 10 30 71 57 47 40 34 28 24 20 17 15 12 10 71 55 45 37 30 25 21 17 14 11 9 0 0 67 51 41 34 27 22 18 14 11 9 7

COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC RW 0 1 2 3 4 5 6 7 8 9 10 80 70 104 93 83 76 68 62 56 51 46 43 39 50 104 87 75 65 57 49 43 38 33 30 26 30 104 83 68 57 48 41 35 29 25 22 18 10 104 79 63 51 41 34 28 23 19 16 13 70 98 87 79 71 64 58 53 48 43 40 36 70 50 98 83 71 62 54 47 41 36 31 28 25 30 98 79 65 55 46 39 33 28 24 21 17 10 98 75 60 49 40 33 27 22 18 16 12 50 88 74 64 55 48 42 37 32 28 25 22 50 30 88 71 59 50 41 35 30 25 22 19 16 10 88 68 55 45 36 30 25 20 17 14 11 50 79 66 57 49 43 37 33 28 25 22 19 30 30 79 63 53 45 37 32 27 23 19 17 14 10 79 61 49 41 33 27 23 18 15 13 10 50 70 59 50 44 38 33 29 25 22 19 17 10 30 70 57 47 40 34 28 24 20 17 15 12 10 70 55 45 37 30 25 20 17 14 11 9 0 0 66 51 41 34 27 22 18 14 11 9 7

COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC RW 0 1 2 3 4 5 6 7 8 9 10 70 108 96 86 78 70 64 58 53 48 44 40 80 50 30 108 108 90 86 78 71 67 59 58 49 51 42 45 36 39 30 34 26 31 22 27 19 10 108 81 65 52 43 35 29 24 20 17 14 70 102 90 81 73 66 60 54 49 45 41 38 70 50 30 102 102 86 81 74 67 64 56 55 47 48 40 42 34 37 29 33 25 29 21 25 18 10 102 77 62 50 41 34 28 23 19 16 13 50 91 76 66 57 49 43 38 33 29 26 23 50 30 91 73 61 51 43 36 31 26 22 19 16 10 91 70 56 46 37 31 26 21 17 15 12 50 82 68 59 51 44 38 34 29 26 23 20 30 30 82 66 55 46 39 33 28 23 20 17 14 10 82 63 51 42 34 28 23 19 16 13 10 50 73 61 52 45 39 34 30 26 23 20 17 10 30 73 9 49 41 35 29 25 21 18 15 13 10 73 57 46 38 31 25 21 17 14 12 9 0 0 69 53 42 35 28 23 18 15 12 10 7

PHOTOMETRIC REPORT CAT. NO.: SWx-400W-x1ASx


145 125 115 105

CANDELA DISTRIBUTION
0 5 15 25 35 45 55 65 75 85 90 95 105 115 125 135 145 155 165 175 180 4623 4423 4242 4207 4987 8287 7509 4374 3092 2277 2845 4229 4104 1436 792 587 204 0 0 0 0

PHOTOMETRIC REPORT CAT. NO.: SWx-350W-x1ASx


145 125 115 105

CANDELA DISTRIBUTION
0 5 15 25 35 45 55 65 75 85 90 95 105 115 125 135 145 155 165 175 180 3993 3820 3664 3634 4307 7157 6485 3777 2670 1967 2457 3652 3544 1240 684 507 176 0 0 0 0

PHOTOMETRIC REPORT CAT. NO.: SWx-320W-x1ASx


125 115 105 95

CANDELA DISTRIBUTION
0 5 15 25 35 45 55 65 75 85 90 95 105 115 125 135 145 155 165 175 180 3399 3231 3113 3091 3485 6143 5894 3355 2254 1558 1777 2889 3130 1103 576 417 142 0 0 0 0

95

95

85
00 18 00 24 00 30 00 36 00 42 00 4 0 80 54 00

V E R T I C A L LY

V E R T I C A L LY

1600 2400 3200 4000 4800 5600 6400

75

1400 2100 2800 3500 4200 4900 5600

12

75

75

65

65

65

55

55

55

45 35

15 TEST NO.: LUMINAIRE:

25

35

45

15 TEST NO.: LUMINAIRE:

25

35

45

15 TEST NO.: LUMINAIRE:

25

LAMP(S): EACH RATED: LINE POWER:

HP-08709 SUPERWATT Reflective Material: STEEL (post painted) Finish: WHITE PAINT Closure: PRISMATIC ACRYLIC UVA-825 HID ONE MVR400/VBU/PA 44000 LUMENS 453 WATTS

ZONAL LUMEN SUMMARY


DEG ZONE 0-30 0-40 0-60 0-90 90-120 90-180 0-180 LUMENS 3571 6825 19615 29977 10112 11402 41379 % LAMP 8.1 15.5 44.6 68.1 23.0 25.9 94.0 % FIXT 8.6 16.5 47.4 72.4 24.4 27.6 100.0

LAMP(S): EACH RATED: LINE POWER:

HP-08758 SUPERWATT Reflective Material: STEEL (post painted) Finish: WHITE PAINT Closure: PRISMATIC ACRYLIC UVA-825-HID ONE MH350W/U/PS 38000 LUMENS 395 WATTS

ZONAL LUMEN SUMMARY


DEG ZONE 0-30 0-40 0-60 0-90 90-120 90-180 0-180 LUMENS 3085 5894 16940 25888 8732 9845 35733 % LAMP 8.1 15.5 44.6 68.1 23.0 25.9 94.0 % FIXT 8.6 16.5 47.4 72.4 24.4 27.6 100.0

LAMP(S): EACH RATED: LINE POWER:

HP-08759 SUPERWATT Reflective Material: STEEL (post painted) Finish: WHITE PAINT Closure: CLEAR PRISMATIC ACRYLIC UVA-825-HID ONE MS320/BU/PS 31400 LUMENS 365 WATTS

V E R T I C A L LY
DEG ZONE 0-30 0-40 0-60 0-90 90-120 90-180 0-180

85

85

ZONAL LUMEN SUMMARY


LUMENS 2625 4896 14563 22132 7343 8275 30407 % LAMP 8.4 15.6 46.4 70.5 23.4 26.4 96.8 % FIXT 8.6 16.1 47.9 72.8 24.1 27.2 100.0

TOTAL LUMINAIRE EFFICIENCY: 94.0% TOTAL REFLECTANCE OF PAINT: 93.1% SHIELDING ANGLE IN DEGREES: PARALLEL 0 NORMAL 0

SPACING CRITERION
0-DEG 2.3 90-DEG 2.3 BTWN 4 2.2

TOTAL LUMINAIRE EFFICIENCY: 94.0% TOTAL REFLECTANCE OF PAINT: 93.1% SHIELDING ANGLE IN DEGREES: PARALLEL 0 NORMAL 0

SPACING CRITERION
0-DEG 2.3 90-DEG 2.3 BTWN 4 2.2

TOTAL LUMINAIRE EFFICIENCY: 96.8% TOTAL REFLECTANCE OF PAINT: 93.1% SHIELDING ANGLE IN DEGREES: PARALLEL 0 NORMAL 0

SPACING CRITERION
0-DEG 2.4 90-DEG 2.4 BTWN 4 2.2

COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC RW 0 1 2 3 4 5 6 7 8 9 10 80 70 106 94 85 77 69 63 57 52 48 44 40 50 106 89 76 66 57 50 44 39 34 30 27 30 106 84 69 58 49 41 35 30 26 22 19 10 106 80 63 51 42 34 29 24 20 17 14 70 101 89 80 72 65 59 54 49 45 41 37 70 50 30 101 101 84 80 72 66 63 55 54 46 47 39 42 34 37 29 32 24 29 21 25 18 10 101 76 61 49 40 33 28 23 19 16 13 50 90 75 65 56 49 42 37 33 29 26 22 50 30 90 72 60 50 42 36 30 26 22 19 16 10 90 69 55 45 37 30 25 21 17 15 12 50 81 67 58 50 43 38 33 29 26 23 20 30 30 81 64 54 45 38 32 27 23 20 17 14 10 81 62 50 41 33 28 23 19 16 13 10 50 72 60 51 44 38 33 29 26 23 20 17 10 30 72 58 48 40 34 29 24 21 18 15 13 10 72 56 45 37 30 25 21 17 14 12 9 0 0 68 52 41 34 27 22 18 15 12 10 7

COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC RW 0 1 2 3 4 5 6 7 8 9 10 80 70 106 94 85 77 69 63 57 52 48 44 40 50 106 89 76 66 57 50 44 39 34 30 27 30 106 84 69 58 49 41 35 30 26 22 19 10 106 80 63 51 42 34 29 24 20 17 14 70 70 50 30 101 01 101 89 84 80 80 72 66 72 63 55 65 54 46 59 47 39 54 42 34 49 37 29 45 32 24 41 29 21 37 25 18 10 101 76 61 49 40 33 28 23 19 16 13 50 90 75 65 56 49 42 39 33 29 26 23 50 30 90 72 60 50 42 36 30 26 22 19 16 10 90 69 55 45 37 30 25 21 17 15 12 50 81 67 58 50 43 38 33 29 26 23 20 30 30 81 64 54 45 38 32 27 23 20 17 14 10 81 62 50 41 33 28 23 19 16 13 10 50 72 60 51 44 38 33 29 26 23 20 17 10 30 72 58 48 40 34 29 24 21 18 15 13 10 72 56 45 37 30 25 21 17 14 12 9 0 0 68 52 41 34 27 22 18 15 12 10 7

COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC RW 0 1 2 3 4 5 6 7 8 9 10 70 110 98 88 80 72 65 59 54 49 45 41 80 50 30 110 110 93 88 79 72 69 60 59 53 52 42 45 36 40 31 35 26 31 23 28 19 10 110 83 66 53 43 36 30 24 20 17 14 70 104 93 83 75 67 61 56 50 46 42 39 70 50 30 104 104 88 83 75 69 65 57 56 48 49 41 43 35 38 29 33 25 30 22 26 18 10 104 79 63 51 42 34 28 23 19 16 13 50 94 78 67 58 50 44 39 34 30 27 23 50 30 94 75 62 52 44 37 31 27 23 20 17 10 94 72 57 47 38 31 26 21 18 15 12 50 84 70 60 52 45 39 34 30 26 24 21 30 30 84 67 56 47 39 33 28 24 20 18 15 10 84 65 52 43 35 28 24 19 16 13 11 50 75 62 53 46 40 35 30 26 23 21 18 10 30 75 60 50 42 35 30 25 21 18 16 13 10 75 58 47 39 31 26 21 17 14 12 9 0 0 71 54 43 35 28 23 19 15 12 10 7

158

PHOTOMETRICS
3 DIMENSIONAL LIGHTING
Lightwatt For complete spacing-to-mounting height ratios, visit our web site at www.hubbell-ltg.com
PHOTOMETRIC REPORT CAT. NO.: LWx-42Fx-A
125 115 105 95

CANDELA DISTRIBUTION
0 5 15 25 35 45 55 65 75 85 90 95 105 115 125 135 145 155 165 175 180 329 337 359 374 377 377 368 340 285 241 222 200 140 75 29 4 0 0 0 0 0

PHOTOMETRIC REPORT CAT. NO.: LWx-64Fx-A


125 115 105 95

CANDELA DISTRIBUTION
0 5 15 25 35 45 55 65 75 85 90 95 105 115 125 135 145 155 165 175 180 704 702 672 625 583 565 552 495 375 268 240 231 198 119 46 6 0 0 0 0 0

PHOTOMETRIC REPORT CAT. NO.: LWx-84Fx-A


125 115 105 95

CANDELA DISTRIBUTION
0 5 15 25 35 45 55 65 75 85 90 95 105 115 125 135 145 155 165 175 180 882 880 841 778 725 703 692 639 521 381 328 304 246 151 63 8 0 0 0 0 0

85 V E R T I C A L LY
80 120 160 200 240 280 320 360

85
140

85
180 270 360 450 540 830 720 810 900

V E R T I C A L LY

75

210 280 350 420 490 560 630 700

75

75

65

65

65

55

55

55

45 25 35 HP-08284 LIGHTWATT Reflective Material: STEEL Finish: WHITE PAINT Closure: PRISMATIC ACRYLIC UVA-825 ONE PLT42W-35-4P 3200 LUMENS 43 WATTS

45 25 35

45 25 35

15 TEST NO.: LUMINAIRE:

15 TEST NO.: LUMINAIRE:

15 TEST NO.: LUMINAIRE:

ZONAL LUMEN SUMMARY


DEG ZONE 0-30 0-40 0-60 0-90 90-120 90-180 0-180 LUMENS 307 544 1165 2066 442 472 2538 % LAMP 9.6 17.0 36.4 64.6 13.8 14.8 79.3 % FIXT 12.1 21.4 45.9 81.4 17.4 18.6 100.0

LAMP(S): EACH RATED: LINE POWER:

LAMP(S): EACH RATED: LINE POWER:

HP-08285 LIGHTWATT Reflective Material: STEEL Finish: WHITE PAINT Closure: PRISMATIC ACRYLIC UVA-825 TWO PLT32W-30-4P 2400 LUMENS 73 WATTS

ZONAL LUMEN SUMMARY


DEG ZONE 0-30 0-40 0-60 0-90 90-120 90-180 0-180 LUMENS 546 913 1846 3026 579 627 3653 % LAMP 11.4 19.0 38.5 63.0 12.1 13.1 76.1 % FIXT 14.9 25.0 50.5 82.8 15.8 17.2 100.0

LAMP(S): EACH RATED: LINE POWER:

HP-08286 LIGHTWATT Reflective Material: STEEL Finish: WHITE PAINT Closure: PRISMATIC ACRYLIC UVA-825 TWO PLT42W-35-4P 3200 LUMENS 82 WATTS

V E R T I C A L LY
DEG ZONE 0-30 0-40 0-60 0-90 90-120 90-180 0-180

ZONAL LUMEN SUMMARY


LUMENS 681 1137 2301 3901 743 808 4709 % LAMP 10.6 17.8 36.0 61.0 11.6 12.6 73.6 % FIXT 14.5 24.1 48.9 82.8 15.8 17.2 100.0

TOTAL LUMINAIRE EFFICIENCY: 79.3% TOTAL REFLECTANCE OF PAINT: 89.6% SHIELDING ANGLE IN DEGREES: PARALLEL 0 NORMAL 0

SPACING CRITERION
0-DEG 1.7 90-DEG 1.7 BTWN 4 1.9

TOTAL LUMINAIRE EFFICIENCY: 76.1% TOTAL REFLECTANCE OF PAINT: 88.8% SHIELDING ANGLE IN DEGREES: PARALLEL 0 NORMAL 0

SPACING CRITERION
0-DEG 1.3 90-DEG 1.3 BTWN 4 1.5

TOTAL LUMINAIRE EFFICIENCY: 73.6% TOTAL REFLECTANCE OF PAINT: 87.8% SHIELDING ANGLE IN DEGREES: PARALLEL 0 NORMAL 0

SPACING CRITERION
0-DEG 1.3 90-DEG 1.3 BTWN 4 1.5

COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC RW 0 1 2 3 4 5 6 7 8 9 10 80 70 90 79 70 63 57 51 47 43 39 36 34 50 90 74 62 53 46 40 35 31 28 25 22 30 90 69 55 46 38 32 27 24 21 18 16 10 90 65 49 39 32 26 22 18 15 13 11 70 86 75 66 59 54 48 44 41 37 34 32 70 50 86 70 59 51 44 38 34 30 27 24 21 30 86 66 53 44 37 31 26 23 20 17 15 10 86 62 47 38 31 25 21 18 15 13 11 50 79 64 53 46 40 34 30 27 24 22 20 50 30 79 60 48 40 34 28 24 21 18 16 14 10 79 57 44 35 29 23 19 16 14 12 10 50 72 58 48 41 36 31 27 24 22 20 18 30 30 72 55 44 37 31 26 22 19 17 14 13 10 72 53 40 33 27 22 18 15 13 11 9 50 66 52 43 37 32 28 25 22 20 18 16 10 30 66 50 40 33 28 23 20 17 15 13 12 10 66 48 37 30 25 20 17 14 12 10 8 0 0 63 45 34 27 22 18 14 12 10 8 7

COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC RW 0 1 2 3 4 5 6 7 8 9 10 80 70 87 77 68 62 56 51 46 42 39 36 33 50 87 72 61 53 46 40 35 31 28 25 23 30 87 68 55 46 38 32 28 24 21 18 16 10 87 64 50 40 33 27 22 19 16 14 12 70 83 73 65 59 53 48 44 40 37 34 32 70 50 83 69 58 50 44 38 34 30 27 24 22 30 83 65 53 44 37 31 27 23 20 18 16 10 83 62 48 39 32 26 22 19 16 13 12 50 76 63 53 46 40 35 31 27 25 22 20 50 30 76 60 49 41 34 29 25 22 19 16 15 10 76 57 45 36 30 24 20 17 15 13 11 50 70 58 48 42 37 32 28 25 22 20 18 30 30 70 55 45 37 32 27 23 20 17 15 14 10 70 53 41 34 28 23 19 16 14 12 10 50 64 53 44 38 33 29 26 23 21 18 17 10 30 64 51 41 34 29 25 21 19 16 14 13 10 64 49 38 31 26 21 18 15 13 11 10 0 0 62 46 36 29 24 19 16 13 11 9 8

COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC RW 0 1 2 3 4 5 6 7 8 9 10 80 70 84 74 66 59 54 49 44 41 37 34 32 50 84 69 58 50 44 38 34 30 27 24 22 30 84 65 52 43 37 31 26 23 20 17 16 10 84 61 47 38 31 25 21 18 15 13 11 70 80 70 62 56 51 46 42 39 35 33 30 70 50 80 66 56 48 42 36 32 29 26 23 21 30 80 62 50 42 35 30 25 22 19 17 15 10 80 59 45 37 30 25 21 18 15 13 11 50 74 60 51 44 38 33 29 26 23 21 19 50 30 74 57 46 39 33 37 24 21 18 16 14 10 74 55 42 34 28 23 19 16 14 12 10 50 68 55 46 40 35 30 27 24 21 19 18 30 30 68 53 42 35 30 25 22 19 17 14 13 10 68 50 39 32 26 21 18 15 13 11 10 50 62 50 42 36 32 27 24 22 20 18 16 10 30 62 48 39 33 28 23 20 18 15 13 12 10 62 47 36 30 24 20 17 14 12 10 9 0 0 59 44 34 27 22 18 15 13 10 9 7

PHOTOMETRIC REPORT CAT. NO.: LWx-175Hx-A


125 115 105 95

CANDELA DISTRIBUTION
0 5 15 25 35 45 55 65 75 85 90 95 105 115 125 135 145 155 165 175 180 1464 1413 1502 2011 2124 2316 1860 1225 927 1088 1217 1418 940 255 105 13 0 0 0 0 0

PHOTOMETRIC REPORT CAT. NO.: LWx-150Hx-A


125 115 105 95

CANDELA DISTRIBUTION
0 5 15 25 35 45 55 65 75 85 90 95 105 115 125 135 145 155 165 175 180 1790 1826 1884 2274 2354 2475 2024 1376 1060 1216 1390 1648 940 259 111 14 0 0 0 0 0

PHOTOMETRIC REPORT CAT. NO.: LWx-100Hx-A


125 115 105 95

CANDELA DISTRIBUTION
0 5 15 25 35 45 55 65 75 85 90 95 105 115 125 135 145 155 165 175 180 994 1010 1084 1299 1387 1479 1214 820 601 643 796 1002 595 157 71 9 0 0 0 0 0

85 V E R T I C A L LY
40 0 60 0 80 0 10 00 12 00 14 00 16 00 18 00 20 00

85 V E R T I C A L LY
0 80 0 00 12 00 1 0 40 16 00 1 0 80 0 20 0 00 22

85
30 0

75

60

75

75
50 0 70 0 90 0 11 00 13 00

65

10

65

65

55

55

55

45 5 15 TEST NO.: LUMINAIRE: 25 35 HP-08738 LIGHTWATT Reflective Material: STEEL Finish: WHITE PAINT Closure: PRISMATIC ACRYLIC UVA-825-HID ONE MH175/U/MED 13500 LUMENS 210 WATTS

45 5 15 TEST NO.: LUMINAIRE: 25 35 HP-08740 LIGHTWATT Reflective Material: STEEL Finish: WHITE PAINT Closure: PRISMATIC ACRYLIC UVA-825-HID ONE MH150/U/PS 15000 LUMENS 185 WATTS

45 5 15 TEST NO.: LUMINAIRE: 25 35 HP-08742 LIGHTWATT Reflective Material: STEEL Finish: WHITE PAINT Closure: PRISMATIC ACRYLIC UVA-825-HID ONE MHC100/U/M4K 9000 LUMENS 129 WATTS

ZONAL LUMEN SUMMARY


DEG ZONE 0-30 0-40 0-60 0-90 90-120 90-180 0-180 LUMENS 1505 2855 6263 9648 2843 2950 12598 % LAMP 11.1 21.1 46.4 71.5 21.1 21.9 93.3 % FIXT 11.9 22.7 49.7 76.6 22.6 23.4 100.0

V E R T I C A L LY
DEG ZONE 0-30 0-40 0-60 0-90 90-120 90-180 0-180

ZONAL LUMEN SUMMARY


DEG ZONE 0-30 0-40 0-60 0-90 90-120 90-180 0-180 LUMENS 1770 3253 6944 10764 3088 3201 13965 % LAMP 11.8 21.7 46.3 71.8 20.6 21.3 93.1 % FIXT 12.7 23.3 49.7 77.1 22.1 22.9 100.0

ZONAL LUMEN SUMMARY


LUMENS 1011 1882 4105 6291 1935 2007 8298 % LAMP 11.2 20.9 45.6 69.9 21.5 22.3 92.2 % FIXT 12.2 22.7 49.5 75.8 23.3 24.2 100.0

LAMP(S): EACH RATED: LINE POWER:

LAMP(S): EACH RATED: LINE POWER:

LAMP(S): EACH RATED: LINE POWER:

TOTAL LUMINAIRE EFFICIENCY: 93.3% TOTAL REFLECTANCE OF PAINT: 91.9% SHIELDING ANGLE IN DEGREES: PARALLEL 0 NORMAL 0

SPACING CRITERION
0-DEG 2.1 90-DEG 2.1 BTWN 4 2.0

TOTAL LUMINAIRE EFFICIENCY: 93.1% TOTAL REFLECTANCE OF PAINT: 91.9% SHIELDING ANGLE IN DEGREES: PARALLEL 0 NORMAL 0

SPACING CRITERION
0-DEG 2.0 90-DEG 2.0 BTWN 4 1.9

TOTAL LUMINAIRE EFFICIENCY: 92.2% TOTAL REFLECTANCE OF PAINT: 91.9% SHIELDING ANGLE IN DEGREES: PARALLEL 0 NORMAL 0

SPACING CRITERION
0-DEG 2.1 90-DEG 2.1 BTWN 4 2.0

COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC RW 0 1 2 3 4 5 6 7 8 9 10 80 70 106 93 84 77 70 63 58 53 49 45 41 50 106 87 75 66 58 51 45 40 36 32 28 30 106 82 68 58 49 42 36 32 27 24 20 10 106 78 62 51 42 36 30 26 22 19 15 70 101 88 80 72 66 60 55 50 46 42 39 70 50 30 101 101 83 79 72 65 63 55 55 47 48 40 43 35 38 30 34 26 31 23 27 19 10 101 74 60 49 41 34 29 25 21 18 15 50 92 75 65 57 50 44 39 35 31 28 24 50 30 92 72 60 51 43 37 32 28 24 21 18 10 92 68 55 46 38 32 27 23 20 17 13 50 83 68 59 52 45 43 36 32 28 25 22 30 30 83 65 54 47 40 34 30 26 22 20 16 10 83 62 51 42 35 30 25 21 18 16 12 50 75 61 53 46 41 36 32 29 26 23 20 10 30 75 59 49 42 36 31 27 24 21 18 15 10 75 57 46 39 33 27 24 20 17 14 11 0 0 72 53 43 36 30 25 21 18 15 12 10

COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC RW 0 1 2 3 4 5 6 7 8 9 10 80 70 106 93 84 77 70 64 58 53 49 45 41 50 106 87 75 66 58 51 45 40 36 32 28 30 106 82 68 58 49 42 37 32 28 25 21 10 106 78 62 51 43 36 31 26 22 19 16 70 101 88 80 72 66 60 55 50 46 43 39 70 50 30 101 101 83 79 72 65 63 55 55 47 49 41 43 35 39 31 34 27 31 24 27 20 10 101 74 60 49 41 35 30 25 21 19 15 50 92 75 65 57 50 44 40 35 31 28 25 50 30 92 72 60 51 43 38 33 28 25 22 18 10 92 68 55 46 38 32 28 24 20 17 14 50 83 68 59 52 45 40 36 32 29 26 23 30 30 83 65 55 47 40 35 30 26 23 20 17 10 83 62 51 43 35 30 26 22 19 16 13 50 76 61 53 47 41 36 33 29 26 24 20 10 30 76 59 50 43 37 32 28 24 21 19 16 10 76 57 47 39 33 28 24 20 17 15 12 0 0 72 53 43 36 30 25 22 18 15 13 10

COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC RW 0 1 2 3 4 5 6 7 8 9 10 70 103 91 83 75 68 62 57 52 48 44 40 80 50 30 103 103 86 81 74 67 65 57 57 48 50 42 45 36 40 31 35 27 32 24 28 20 10 103 77 61 51 42 35 30 25 22 19 15 70 99 87 78 71 64 59 54 49 45 42 38 70 50 99 82 71 62 54 48 42 38 34 30 26 30 99 77 64 55 46 40 35 30 26 23 19 10 99 73 59 49 40 34 29 25 21 18 15 50 89 74 64 56 49 43 39 34 31 28 24 50 30 89 70 59 50 43 37 32 28 24 21 18 10 89 67 54 45 38 32 27 23 20 17 14 50 81 67 58 51 44 39 35 31 28 25 22 30 30 81 64 54 46 39 34 29 26 22 20 16 10 81 61 50 42 35 29 25 21 18 16 13 50 73 60 52 46 40 35 32 28 25 23 20 10 30 73 58 49 42 36 31 27 23 20 18 15 10 73 56 46 38 32 27 23 20 17 14 12 0 0 70 52 42 35 29 25 21 18 15 13 10

159

PHOTOMETRICS
3 DIMENSIONAL LIGHTING
Tribay Superwatt For complete spacing-to-mounting height ratios, visit our web site at www.hubbell-ltg.com
PHOTOMETRIC REPORT CAT. NO.: CH-40-H-x-x-SW
145 125 115 105 95

CANDELA DISTRIBUTION
0 5 15 25 35 45 55 65 75 85 90 95 105 115 125 135 145 155 165 175 180 3925 3747 3632 3703 4713 7170 5965 3323 2264 1836 2559 3632 3279 1200 635 457 164 0 0 0 0

PHOTOMETRIC REPORT CAT. NO.: CH-40-S-x-x-SW


145 125 115 105 95

CANDELA DISTRIBUTION
0 5 15 25 35 45 55 65 75 85 90 95 105 115 125 135 145 155 165 175 180 5143 4866 4689 4978 6255 9007 8254 5188 3036 2955 3676 4522 4088 1713 886 606 227 0 0 0 0

PHOTOMETRIC REPORT CAT. NO.: CH-25-H-x-x-SW


145 125 115 105 95

CANDELA DISTRIBUTION
0 5 15 25 35 45 55 65 75 85 90 95 105 115 125 135 145 155 165 175 180 2203 2101 2035 2074 2647 4070 3477 1839 1264 932 1307 2003 1912 681 353 257 92 0 0 0 0

85 V E R T I C A L LY

85 V E R T I C A L LY

85 V E R T I C A L LY
DEG ZONE 0-30 0-40 0-60 0-90 90-120 90-180 0-180

0 140 210 0 0

75

180

0 0 0 0

75

800 120 0 0 0

75

270

280 3

65

360

65

160

65

500

450

200

420

55

540

0 0
55

240

0 0 0 0
25 35

55

0 490 560 6
5 15 TEST NO.: LUMINAIRE:

630

280

0
45 25 35

0 720 810
5 15 TEST NO.: LUMINAIRE:

0
45 25 35

320

300
HP-06354 Tribay 2.0 Superwatt Finish: WHITE PAINT Optics: ALUMINUM ONE MVR-400/U 36,000 LUMENS 460 WATTS

360
5 15

45

ZONAL LUMEN SUMMARY


DEG ZONE 0-30 0-40 0-60 0-90 90-120 90-180 0-180 LUMENS 3117 6170 16867 24816 8405 9435 34251 % LAMP 8.7 17.1 46.9 68.9 23.3 26.2 95.1 % FIXT 9.1 18.0 49.2 72.5 24.5 27.5 100.0

LAMP(S): EACH RATED: LINE POWER:

LAMP(S): EACH RATED: LINE POWER:

HP-06355 Tribay 2.0 Superwatt Finish: WHITE PAINT Optics: ALUMINUM ONE C400S51 50,000 LUMENS 465 WATTS

ZONAL LUMEN SUMMARY


DEG ZONE 0-30 0-40 0-60 0-90 90-120 90-180 0-180 LUMENS 4120 8146 22391 34047 10997 12414 46461 % LAMP 8.2 16.3 44.8 68.1 22.0 24.8 92.9 % FIXT 8.9 17.5 48.2 73.3 23.7 26.7 100.0

TEST NO.: LUMINAIRE:

LAMP(S): EACH RATED: LINE POWER:

HP-06356 Tribay 2.0 Superwatt Finish: WHITE PAINT Optics: ALUMINUM ONE MVR-250/U 20,500 LUMENS 285 WATTS

ZONAL LUMEN SUMMARY


LUMENS 1743 3450 9612 13902 4722 5298 19200 % LAMP 8.5 16.8 46.9 67.8 23.0 25.8 93.7 % FIXT 9.1 18.0 50.1 72.4 24.6 27.6 100.0

TOTAL LUMINAIRE EFFICIENCY: 95.1% TOTAL REFLECTANCE OF PAINT: 91.9% SHIELDING ANGLE IN DEGREES: PARALLEL 0 NORMAL 0

SPACING CRITERION
0-DEG 2.3 90-DEG 2.3 BTWN 4 2.1

TOTAL LUMINAIRE EFFICIENCY: 92.9% TOTAL REFLECTANCE OF PAINT: 91.9% SHIELDING ANGLE IN DEGREES: PARALLEL 0 NORMAL 0

SPACING CRITERION
0-DEG 2.3 90-DEG 2.3 BTWN 4 2.1

TOTAL LUMINAIRE EFFICIENCY: 93.7% TOTAL REFLECTANCE OF PAINT: 91.9% SHIELDING ANGLE IN DEGREES: PARALLEL 0 NORMAL 0

SPACING CRITERION
0-DEG 2.3 90-DEG 2.3 BTWN 4 2.1

COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC RW 0 1 2 3 4 5 6 7 8 9 10 80 70 107 95 86 78 71 64 58 53 48 45 41 50 107 90 78 68 59 51 45 40 35 31 27 30 107 85 71 59 50 42 36 31 27 23 19 10 107 81 65 53 43 36 30 25 21 18 14 70 101 90 81 73 66 60 55 50 45 42 38 70 50 30 101 101 85 81 74 67 64 57 56 48 49 40 43 35 38 30 33 25 30 22 26 18 10 101 77 62 51 42 34 29 24 20 17 13 50 91 76 66 57 50 44 38 34 30 26 23 50 30 91 73 61 51 43 37 32 27 23 20 17 10 91 70 56 46 38 32 26 22 18 15 12 50 81 68 59 51 44 39 34 30 26 24 20 30 30 81 65 55 46 39 33 29 24 21 18 15 10 81 63 51 42 35 29 24 20 16 14 11 50 73 60 52 45 39 34 30 27 23 21 18 10 30 73 58 49 42 35 30 26 22 18 16 13 10 73 57 46 38 32 26 22 18 15 12 10 0 0 69 53 43 35 29 23 19 16 13 10 8

COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC RW 0 1 2 3 4 5 6 7 8 9 10 80 70 104 93 84 76 68 62 56 51 47 43 39 50 104 87 75 65 56 49 43 38 34 30 26 30 104 82 68 57 48 40 35 29 25 22 19 10 104 78 62 51 41 34 28 23 19 17 13 70 99 87 79 71 64 58 53 48 44 40 37 70 50 99 83 71 62 53 47 41 36 32 28 25 30 99 78 65 54 46 39 33 28 24 21 18 10 99 74 59 49 39 33 27 22 19 16 13 50 89 74 64 55 48 42 37 32 29 26 22 50 30 89 71 59 49 41 35 30 26 22 19 16 10 89 68 54 45 36 30 25 21 17 14 12 50 80 66 57 50 43 37 33 29 25 23 20 30 30 80 64 53 45 38 32 27 23 20 17 14 10 80 61 49 41 33 27 23 19 16 13 10 50 72 59 51 44 38 33 29 26 23 20 17 10 30 72 57 48 40 34 29 24 21 18 15 13 10 72 55 45 37 30 25 21 17 14 12 9 0 0 68 51 41 34 27 22 18 15 12 10 7

COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC RW 0 1 2 3 4 5 6 7 8 9 10 70 106 94 85 77 70 63 58 53 48 44 40 80 50 30 106 106 89 85 77 70 67 59 58 50 51 42 45 36 39 31 35 26 31 23 27 19 10 106 80 64 53 43 36 30 25 20 17 14 70 100 89 80 73 66 60 54 49 45 41 38 70 50 30 100 100 85 80 73 67 64 56 55 47 48 40 42 34 37 29 33 25 29 22 26 18 10 100 77 62 51 41 34 29 24 20 17 13 50 90 76 65 57 49 43 38 33 29 26 23 50 30 90 72 60 51 43 37 31 27 23 20 16 10 90 69 56 46 38 31 26 22 18 15 12 50 80 67 58 51 44 39 34 30 26 23 20 30 30 80 65 54 46 39 33 28 24 20 18 15 10 80 63 51 42 35 29 24 20 16 14 11 50 72 60 52 45 39 34 30 26 23 21 18 10 30 72 58 49 41 35 30 25 21 18 16 13 10 72 56 46 38 31 26 22 18 15 12 9 0 0 68 52 42 35 28 23 19 15 12 10 8

PHOTOMETRIC REPORT CAT. NO.: LW2x-64Fx-A


145 125 115 105 95

CANDELA DISTRIBUTION
0 5 15 25 35 45 55 65 75 85 90 95 105 115 125 135 145 155 165 175 180 703 701 671 624 582 564 551 494 375 268 239 230 198 119 46 6 0 0 0 0 0

PHOTOMETRIC REPORT CAT. NO.: LW2x-42Fx-A


145 125 115 105 95

CANDELA DISTRIBUTION
0 5 15 25 35 45 55 65 75 85 90 95 105 115 125 135 145 155 165 175 180 329 337 359 374 377 377 368 340 285 241 222 200 140 75 29 4 0 0 0 0 0

PHOTOMETRIC REPORT CAT. NO.: LW2x-84Fx-A


145 125 115 105 95

CANDELA DISTRIBUTION
0 5 15 25 35 45 55 65 75 85 90 95 105 115 125 135 145 155 165 175 180 882 880 841 778 725 703 692 639 521 381 328 304 246 151 63 8 0 0 0 0 0

85

85 V E R T I C A L LY
80 120 160 200 240 280 320 360

85 V E R T I C A L LY
DEG ZONE 0-30 0-40 0-60 0-90 90-120 90-180 0-180

140 200 280 350 420 480 560 600 700 770
5 15 TEST NO.: LUMINAIRE: 25 35 HP-07471 LIGHTWATT haz location Reflective Material: STEEL Finish: WHITE PAINT Closure: UVA-825 PRISMATIC ACRYLIC REFRACTOR TWO PLT32W-30-4P 2400 LUMENS 73 WATTS 45 55 65 75 V E R T I C A L LY

180 270 360 450 540 630 720 810 900


5 15 TEST NO.: LUMINAIRE: 25 35 45 55 65 75

75

65

55

45 25 35 HP-07464 LIGHTWATT haz location Reflective Material: STEEL Finish: WHITE PAINT Closure: UVA-825 PRISMATIC ACRYLIC REFRACTOR ONE PLT42W-35-4P 3200 LUMENS 43 WATTS

15 TEST NO.: LUMINAIRE:

ZONAL LUMEN SUMMARY


DEG ZONE 0-30 0-40 0-60 0-90 90-120 90-180 0-180 LUMENS 545 911 1841 3020 577 625 3645 % LAMP 11.4 19.0 38.4 62.9 12.0 13.0 75.9 % FIXT 15.0 25.0 50.5 82.9 15.8 17.1 100.0

ZONAL LUMEN SUMMARY


DEG ZONE 0-30 0-40 0-60 0-90 90-120 90-180 0-180 LUMENS 307 544 1165 2066 442 472 2538 % LAMP 9.6 17.0 36.4 64.6 13.8 14.8 79.3 % FIXT 12.1 21.4 45.9 81.4 17.4 18.6 100.0

LAMP(S): EACH RATED: LINE POWER:

LAMP(S): EACH RATED: LINE POWER:

LAMP(S): EACH RATED: LINE POWER:

HP-07472 LIGHTWATT haz location Reflective Material: STEEL Finish: WHITE PAINT Closure: UVA-825 PRISMATIC ACRYLIC REFRACTOR TWO PLT42W-35-4P 3200 LUMENS 82 WATTS

ZONAL LUMEN SUMMARY


LUMENS 681 1137 2301 3901 743 808 4709 % LAMP 10.6 17.8 36.0 61.0 11.6 12.6 73.6 % FIXT 14.5 24.1 48.9 82.8 15.8 17.2 100.0

TOTAL LUMINAIRE EFFICIENCY: 75.9% TOTAL REFLECTANCE OF PAINT: 88.8% SHIELDING ANGLE IN DEGREES: PARALLEL 0 NORMAL 0

SPACING CRITERION
0-DEG 1.3 90-DEG 1.3 BTWN 4 1.5

TOTAL LUMINAIRE EFFICIENCY: 79.3% TOTAL REFLECTANCE OF PAINT: 89.6% SHIELDING ANGLE IN DEGREES: PARALLEL 0 NORMAL 0

SPACING CRITERION
0-DEG 1.7 90-DEG 1.7 BTWN 4 1.95

TOTAL LUMINAIRE EFFICIENCY: 73.6% TOTAL REFLECTANCE OF PAINT: 87.8% SHIELDING ANGLE IN DEGREES: PARALLEL 0 NORMAL 0

SPACING CRITERION
0-DEG 1.3 90-DEG 1.3 BTWN 4 1.5

COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC RW 0 1 2 3 4 5 6 7 8 9 10 80 70 87 77 69 63 57 52 47 43 40 37 34 50 87 73 62 54 47 41 36 32 29 26 24 30 87 69 56 47 40 34 29 25 22 19 17 10 87 65 51 41 34 28 24 20 17 15 13 70 84 74 66 60 54 49 45 41 38 35 33 70 50 84 70 59 52 45 39 35 31 28 25 23 30 84 66 54 45 38 33 28 25 22 19 17 10 84 63 49 40 33 27 23 20 17 15 13 50 77 64 55 47 42 36 32 29 26 23 21 50 30 77 61 50 42 36 30 26 23 20 18 16 10 77 59 46 38 31 26 22 19 16 14 12 50 71 59 50 44 38 33 30 27 24 21 20 30 30 71 57 46 39 33 28 25 22 19 17 15 10 71 54 43 36 30 24 21 18 15 13 11 50 66 54 46 40 35 31 27 24 22 20 18 10 30 66 52 43 36 31 26 23 20 18 15 14 10 66 51 40 33 28 23 20 17 14 12 11 0 0 63 48 38 31 26 21 18 15 13 11 9

COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC RW 0 1 2 3 4 5 6 7 8 9 10 80 70 90 79 70 63 57 51 47 43 39 36 34 50 90 74 62 53 46 40 35 31 28 25 22 30 90 69 55 46 38 32 27 24 21 18 16 10 90 65 49 39 32 26 22 18 15 13 11 70 86 75 66 59 54 48 44 41 37 34 32 70 50 86 70 59 51 44 38 34 30 27 24 21 30 86 66 53 44 37 31 26 23 20 17 15 10 86 62 47 38 31 25 21 18 15 13 11 50 79 64 53 46 40 34 30 27 24 22 20 50 30 79 60 48 40 34 28 24 21 18 16 14 10 79 57 44 35 29 23 19 16 14 12 10 50 72 58 48 41 36 31 27 24 22 20 18 30 30 72 55 44 37 31 26 22 19 17 14 13 10 72 53 40 33 27 22 18 15 13 11 9 50 66 52 43 37 32 28 25 22 20 18 16 10 30 66 50 40 33 28 23 20 17 15 13 12 10 66 48 37 30 25 20 17 14 12 10 8 0 0 63 45 34 27 22 18 14 12 10 8 7

COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC RW 0 1 2 3 4 5 6 7 8 9 10 80 70 84 74 66 59 54 49 44 41 37 34 32 50 84 69 58 50 44 38 34 30 27 24 22 30 84 65 52 43 37 31 26 23 20 17 16 10 84 61 47 38 31 25 21 18 15 13 11 70 80 70 62 56 51 46 42 39 35 33 30 70 50 80 66 56 48 42 36 32 29 26 23 21 30 80 62 50 42 35 30 25 22 19 17 15 10 80 59 45 37 30 25 21 18 15 13 11 50 74 60 51 44 38 33 29 26 23 21 19 50 30 74 57 46 39 33 27 24 21 18 16 14 10 74 55 42 34 28 23 19 16 14 12 10 50 68 55 46 40 35 30 27 24 21 19 18 30 30 68 53 42 35 30 25 22 19 17 14 13 10 68 50 39 32 26 21 18 15 13 11 10 50 62 50 42 36 32 27 24 22 20 18 16 10 30 62 48 39 33 28 23 20 18 15 13 12 10 62 47 36 30 24 20 17 14 12 10 9 0 0 59 44 34 27 22 18 15 13 10 9 7

160

PHOTOMETRICS
TRIBAY SERIES
PHOTOMETRIC REPORT CAT. NO.: CH-40-H-x-x-OU
145 125 115 105 95

For complete spacing-to-mounting height ratios, visit our web site at www.hubbell-ltg.com

CANDELA DISTRIBUTION
0 5 15 25 35 45 55 65 75 85 90 95 105 115 125 135 145 155 165 175 180 11998 10176 9907 12286 12036 13210 2530 610 103 29 25 25 39 33 27 22 19 35 104 13 0

PHOTOMETRIC REPORT CAT. NO.: CH-40-H-x-x-EU


145 125 115 105 95

CANDELA DISTRIBUTION
0 5 15 25 35 45 55 65 75 85 90 95 105 115 125 135 145 155 165 175 180 12571 10427 10065 11798 11790 11744 2197 541 109 32 20 21 25 31 30 22 18 30 120 10 11

PHOTOMETRIC REPORT CAT. NO.: CH-40-S-x-x-OU


145 125 115 105 95

CANDELA DISTRIBUTION
0 5 15 25 35 45 55 65 75 85 90 95 105 115 125 135 145 155 165 175 180 16142 14426 14602 15066 16259 16039 6572 933 141 39 34 40 47 54 50 40 29 84 63 18 0

85 V E R T I C A L LY

85 V E R T I C A L LY

85 V E R T I C A L LY
DEG ZONE 0-30 0-40 0-60 0-90 90-120 90-180 0-180

300

75

300

75

400

75

500

65

500

0 600 800 0 00
55 65

65

0 700
55

0 700
55

100

0 900 110 00
45 5 15 130 TEST NO.: LUMINAIRE:

0 900
110 00

120

00 00
45 35

140

45 5

00

25

35

30 15 1
TEST NO.: LUMINAIRE:

00

25

35

00 160 15 18000 25
TEST NO.: LUMINAIRE:

LAMP(S): EACH RATED: LINE POWER:

HP-06163 Tribay 2.0 Superbay Finish: WHITE PAINT Optics: 19" SEMI-SPECULAR ALUMINUM ONE MVR-400/U 36,000 LUMENS 400 WATTS

ZONAL LUMEN SUMMARY


DEG ZONE 0-30 0-40 0-60 0-90 90-120 90-180 0-180 LUMENS 9466 17027 29527 30273 103 202 30475 % LAMP 26.3 47.3 82.0 84.1 0.3 0.6 84.7 % FIXT 31.1 55.9 96.9 99.3 0.3 0.7 100.0

LAMP(S): EACH RATED: LINE POWER:

HP-06188 Tribay 2.0 Superbay Finish: WHITE PAINT Optics: 19" SEMI-SPECULAR ALUMINUM W/ CLEAR FLAT GLASS CLOSURE ONE MVR-400/U 36,000 LUMENS 400 WATTS

ZONAL LUMEN SUMMARY


DEG ZONE 0-30 0-40 0-60 0-90 90-120 90-180 0-180 LUMENS 9309 16715 27781 28468 80 184 28652 % LAMP 25.9 46.4 77.2 79.1 0.2 0.5 79.6 % FIXT 32.5 58.3 97.0 99.4 0.3 0.6 100.0

LAMP(S): EACH RATED: LINE POWER:

HP-06166 Tribay 2.0 Superbay Finish: WHITE PAINT Optics: 19" SEMI-SPECULAR ALUMINUM ONE C400S51 50,000 LUMENS 400 WATTS

ZONAL LUMEN SUMMARY


LUMENS 12489 22703 41020 42137 147 300 42437 % LAMP 25.0 45.4 82.0 84.3 0.3 0.6 84.9 % FIXT 29.4 53.5 96.7 99.3 0.3 0.7 100.0

TOTAL LUMINAIRE EFFICIENCY: 84.7% TOTAL REFLECTANCE OF PAINT: XX% SHIELDING ANGLE IN DEGREES: PARALLEL X NORMAL X

SPACING CRITERION
0-DEG 1.7 90-DEG 1.7 BTWN 4 1.6

TOTAL LUMINAIRE EFFICIENCY: 79.6% TOTAL REFLECTANCE OF PAINT: XX% SHIELDING ANGLE IN DEGREES: PARALLEL X NORMAL X

SPACING CRITERION
0-DEG 1.5 90-DEG 1.5 BTWN 4 1.5

TOTAL LUMINAIRE EFFICIENCY: 84.9% TOTAL REFLECTANCE OF PAINT: XX% SHIELDING ANGLE IN DEGREES: PARALLEL X NORMAL X

SPACING CRITERION
0-DEG 1.6 90-DEG 1.6 BTWN 4 1.6

COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC RW 0 1 2 3 4 5 6 7 8 9 10 80 70 101 95 89 84 78 72 67 62 57 52 46 50 101 92 84 77 70 64 58 52 47 42 35 30 101 89 80 72 64 58 52 46 41 35 29 10 101 87 77 68 60 53 47 41 36 31 25 70 98 93 87 82 76 71 66 61 56 51 45 70 50 98 90 83 76 69 63 57 52 46 41 35 30 98 88 79 71 64 57 51 46 40 35 29 10 98 86 76 68 60 53 47 41 36 31 25 50 94 86 80 74 67 61 56 50 45 40 34 50 30 94 85 77 70 63 56 51 45 40 35 28 10 94 83 74 67 59 52 47 41 36 31 24 50 90 83 77 71 65 60 54 49 44 39 33 30 30 90 82 75 68 61 55 50 44 39 34 28 10 90 80 72 65 58 52 46 41 36 31 24 50 86 80 75 69 63 58 53 48 43 39 33 10 30 86 79 73 67 60 54 49 44 39 34 28 10 86 78 71 64 57 51 46 40 35 31 24 0 0 84 76 69 63 56 50 44 39 34 29 23

COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC RW 0 1 2 3 4 5 6 7 8 9 10 80 70 95 89 84 79 74 69 64 59 54 50 44 50 95 87 79 73 66 61 55 50 45 40 34 30 95 84 76 68 61 55 49 44 39 34 28 10 95 82 73 65 57 51 45 40 35 30 24 70 92 87 82 77 72 67 62 58 53 49 43 70 50 92 85 78 72 65 60 54 49 44 40 34 30 92 83 75 68 61 55 49 44 39 34 28 10 92 81 72 64 57 51 45 40 35 30 24 50 88 81 75 70 64 58 53 48 43 39 33 50 30 88 80 72 66 59 54 48 43 38 34 28 10 88 78 70 63 56 50 45 40 35 30 24 50 84 78 73 68 62 57 52 47 43 38 32 30 30 84 77 70 65 58 53 48 43 38 33 27 10 84 76 68 62 55 50 44 39 35 30 24 50 81 75 71 66 60 55 51 46 42 37 32 10 30 81 74 69 63 57 52 47 42 37 33 27 10 81 73 67 61 55 49 44 39 34 30 24 0 0 79 72 65 60 53 48 43 38 33 28 22

COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC RW 0 1 2 3 4 5 6 7 8 9 10 70 101 95 89 83 77 72 66 61 56 51 46 80 50 30 101 101 92 89 84 80 77 71 69 63 63 56 57 50 51 44 46 39 41 34 35 28 10 101 87 76 67 59 52 46 40 34 30 24 70 98 93 87 81 75 70 65 60 55 50 45 70 50 98 90 82 75 68 62 56 50 45 40 34 30 98 88 79 71 63 56 50 44 39 34 28 10 98 85 75 67 58 52 45 39 34 30 24 50 94 86 79 73 66 60 54 49 44 39 34 50 30 94 84 76 69 61 55 49 43 38 34 28 10 94 83 74 66 58 51 45 39 34 30 24 50 90 83 77 71 64 58 53 48 43 38 33 30 30 90 82 74 67 60 54 48 43 38 33 27 10 90 80 72 64 57 50 45 39 34 29 24 50 86 80 74 69 62 57 52 47 42 37 32 10 30 86 79 72 66 59 53 47 42 37 33 27 10 86 78 70 63 56 50 44 39 34 29 23 0 0 84 76 69 62 55 48 43 37 32 28 22

PHOTOMETRIC REPORT CAT. NO.: CH-10-H-x-x-OU60


145 125 115 105 95

CANDELA DISTRIBUTION
0 5 15 25 35 45 55 65 75 85 90 95 105 115 125 135 145 155 165 175 180 36908 34172 38695 47223 43825 22707 8358 1068 252 129 143 213 120 342 242 136 123 128 158 145 0

PHOTOMETRIC REPORT CAT. NO.: CH-10-H-X-X-EU60


145 125 115 105 95

CANDELA DISTRIBUTION
0 5 15 25 35 45 55 65 75 85 90 95 105 115 125 135 145 155 165 175 180 36162 33911 37509 45229 39819 20124 6303 1005 267 220 147 149 157 221 255 158 135 146 142 147 0

PHOTOMETRIC REPORT CAT. NO.: CH-10-S-x-x-OU60


145 125 115 105 95

CANDELA DISTRIBUTION
0 5 15 25 35 45 55 65 75 85 90 95 105 115 125 135 145 155 165 175 180 55154 48458 38626 36387 34588 31555 23297 11519 2473 320 145 121 159 168 160 169 116 123 129 120 0

85 V E R T I C A L LY

85 V E R T I C A L LY

85 V E R T I C A L LY
DEG ZONE 0-30 0-40 0-60 0-90 90-120 90-180 0-180

00 100 150 00 00 0

75

00 100 150 00 00 000

75

00 120 180 00 00 00

75

200

65

200

65

240

65

0 250

300

25

300

00 00 00
00
25 35

55

55

360

00 00 00
0
25 35

55

300

00 00 00
45

350

420

350

480

400
5

45

400
5

0 540
5 15 TEST NO.: LUMINAIRE:

45

15 450 TEST NO.: LUMINAIRE:

LAMP(S): EACH RATED: LINE POWER:

HP-06171A Tribay-OU Optics: PILLAR 2 Reflective material: ALUMINUM Finish: BRIGHT, DIFFUSE Closure: OPEN ONE MVR-1000/U 110,000 LUMENS 1080 WATTS

ZONAL LUMEN SUMMARY


DEG ZONE 0-30 0-40 0-60 0-90 90-120 90-180 0-180 LUMENS 36112 63076 88374 89917 606 1191 91108 % LAMP 32.8 57.3 80.3 81.7 0.6 1.1 82.8 % FIXT 39.6 69.2 97.0 98.7 0.7 1.3 100.0

15 45000 25 35 TEST NO.: HP-06186A LUMINAIRE: Tribay-EU Reflective Material: ALUMINIM Finish: BRIGHT, DIFFUSE Closure: OPEN LAMP(S): ONE MVR-1000/U EACH RATED: 110,000 LUMENS LINE POWER: 1080 WATTS

ZONAL LUMEN SUMMARY


DEG ZONE 0-30 0-40 0-60 0-90 90-120 90-180 0-180 LUMENS 34743 59188 80773 82255 597 1179 83434 % LAMP 31.6 53.8 73.4 74.8 0.5 1.1 75.8 % FIXT 41.6 70.9 96.8 98.6 0.7 1.4 100.0

LAMP(S): EACH RATED: LINE POWER:

HP-06178A Tribay-OU Optics: PILLAR 5 Reflective Material: ALUMINUM Finish: BRIGHT, DIFFUSE Closure: OPEN ONE C1000S52 140,000 LUMENS 1100 WATTS

ZONAL LUMEN SUMMARY


LUMENS 32249 53949 99088 113725 429 879 114604 % LAMP 23.0 38.5 70.8 81.2 0.3 0.6 81.9 % FIXT 28.1 47.1 86.5 99.2 0.4 0.8 100.0

TOTAL LUMINAIRE EFFICIENCY: 82.8% TOTAL REFLECTANCE OF PAINT: 78.8% SHIELDING ANGLE IN DEGREES: PARALLEL 35 NORMAL 35

SPACING CRITERION
0-DEG 1.6 90-DEG 1.6 BTWN 4 1.4

TOTAL LUMINAIRE EFFICIENCY: 75.8% TOTAL REFLECTANCE OF PAINT: 78.8% SHIELDING ANGLE IN DEGREES: PARALLEL 37 NORMAL 37

SPACING CRITERION
0-DEG 1.5 90-DEG 1.5 BTWN 4 1.3

TOTAL LUMINAIRE EFFICIENCY: 81.9% TOTAL REFLECTANCE OF PAINT: 78.8% SHIELDING ANGLE IN DEGREES: PARALLEL 31 NORMAL 31

SPACING CRITERION
0-DEG 0.9 90-DEG 0.9 BTWN 4 1.3

COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC RW 0 1 2 3 4 5 6 7 8 9 10 80 70 99 93 88 84 78 74 69 64 60 56 50 50 99 91 84 78 71 66 61 55 51 46 40 30 99 88 80 73 66 60 55 50 45 40 34 10 99 86 77 70 63 56 51 46 41 39 30 70 96 91 86 82 77 72 68 63 59 54 49 70 50 96 89 82 77 70 65 60 55 50 46 39 30 96 87 79 73 66 60 55 49 45 40 34 10 96 85 76 69 62 56 51 46 41 36 30 50 92 85 80 74 68 63 58 54 49 45 39 50 30 92 84 77 71 64 59 54 49 44 40 33 10 92 82 75 68 61 56 50 45 41 36 30 50 88 82 77 72 67 62 57 52 48 44 38 30 30 88 81 75 69 63 58 53 48 44 39 33 10 88 79 73 67 60 55 50 45 40 36 30 50 84 79 74 70 65 60 56 51 47 43 37 10 30 84 78 73 68 62 57 52 48 43 39 33 10 84 77 71 66 60 54 49 45 40 36 30 0 0 82 75 70 64 58 53 48 43 39 35 28

COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC RW 0 1 2 3 4 5 6 7 8 9 10 80 70 90 86 81 77 72 68 64 60 56 52 47 50 90 83 77 72 66 61 56 52 48 43 38 30 90 81 74 68 61 56 51 47 42 38 32 10 90 79 71 65 58 53 48 43 39 35 29 70 88 84 79 75 71 67 63 59 55 51 46 70 50 88 81 76 71 65 60 56 51 47 43 37 30 88 80 73 67 61 56 51 46 42 38 32 10 88 78 70 64 58 52 48 43 39 35 29 50 84 78 73 68 63 59 54 50 46 42 37 50 30 84 77 71 65 60 55 50 46 42 38 32 10 84 75 69 63 57 52 47 43 38 35 29 50 80 75 71 66 62 57 53 49 45 41 36 30 30 80 74 69 64 59 54 50 45 41 37 32 10 80 73 67 62 56 51 47 42 38 34 28 50 77 72 68 65 60 56 52 48 44 41 35 10 30 77 71 67 62 57 53 49 45 41 37 31 10 77 71 65 61 55 51 46 42 38 34 28 0 0 75 69 64 59 54 49 45 41 37 33 27

COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC RW 0 1 2 3 4 5 6 7 8 9 10 80 70 97 91 84 78 72 66 61 56 52 48 44 50 97 87 79 71 63 57 51 46 42 38 33 30 97 85 74 65 57 50 45 39 35 31 27 10 97 82 70 61 52 45 40 35 30 27 22 70 95 88 82 76 70 65 60 55 51 47 43 70 50 95 86 77 70 62 56 50 45 41 37 33 30 95 83 73 64 56 50 44 39 35 31 26 10 95 81 69 60 52 45 40 35 30 27 22 50 91 82 74 67 60 54 49 44 40 36 32 50 30 91 80 71 63 55 49 43 38 34 31 26 10 91 78 68 59 51 45 39 34 30 27 22 50 87 79 72 65 58 53 48 43 39 35 31 30 30 87 77 69 61 54 48 43 38 34 30 26 10 87 76 66 58 50 44 39 34 30 26 22 50 83 76 69 63 56 51 46 42 38 35 30 10 30 83 74 67 60 53 47 42 37 33 30 25 10 83 73 65 57 50 44 38 34 30 26 22 0 0 81 72 63 55 48 42 37 32 28 25 20

161

PHOTOMETRICS
TRIBAY SERIES
PHOTOMETRIC REPORT CAT. NO.: CH-40-H-x-x-SW
145 125 115 105 95

For complete spacing-to-mounting height ratios, visit our web site at www.hubbell-ltg.com
CANDELA DISTRIBUTION
0 5 15 25 35 45 55 65 75 85 90 95 105 115 125 135 145 155 165 175 180 3925 3747 3632 3703 4713 7170 5965 3323 2264 1836 2559 3632 3279 1200 635 457 164 0 0 0 0

PHOTOMETRIC REPORT CAT. NO.: CH-40-S-x-x-SW


145 125 115 105 95

CANDELA DISTRIBUTION
0 5 15 25 35 45 55 65 75 85 90 95 105 115 125 135 145 155 165 175 180 5143 4866 4689 4978 6255 9007 8254 5188 3036 2955 3676 4522 4088 1713 886 606 227 0 0 0 0

PHOTOMETRIC REPORT CAT. NO.: CH-25-H-x-x-SW


145 125 115 105 95

CANDELA DISTRIBUTION
0 5 15 25 35 45 55 65 75 85 90 95 105 115 125 135 145 155 165 175 180 2203 2101 2035 2074 2647 4070 3477 1839 1264 932 1307 2003 1912 681 353 257 92 0 0 0 0

85 V E R T I C A L LY

85 V E R T I C A L LY

85 V E R T I C A L LY
DEG ZONE 0-30 0-40 0-60 0-90 90-120 90-180 0-180

0 140 210 0 0

75

180

0 0 0 0

75

800 120 0 0 0

75

270

280 3

65

360

65

160

65

500

450

200

420

55

540

0 0
55

240

0 0 0 0
25 35

55

0 490 560 6
5 15 TEST NO.: LUMINAIRE:

630

280

0
45 25 35

0 720 810
5 15 TEST NO.: LUMINAIRE:

0
45 25 35

320

300
HP-06354 Tribay 2.0 Superwatt Finish: WHITE PAINT Optics: ALUMINUM ONE MVR-400/U 36,000 LUMENS 460 WATTS

360
5 15

45

ZONAL LUMEN SUMMARY


DEG ZONE 0-30 0-40 0-60 0-90 90-120 90-180 0-180 LUMENS 3117 6170 16867 24816 8405 9435 34251 % LAMP 8.7 17.1 46.9 68.9 23.3 26.2 95.1 % FIXT 9.1 18.0 49.2 72.5 24.5 27.5 100.0

LAMP(S): EACH RATED: LINE POWER:

LAMP(S): EACH RATED: LINE POWER:

HP-06355 Tribay 2.0 Superwatt Finish: WHITE PAINT Optics: ALUMINUM ONE C400S51 50,000 LUMENS 465 WATTS

ZONAL LUMEN SUMMARY


DEG ZONE 0-30 0-40 0-60 0-90 90-120 90-180 0-180 LUMENS 4120 8146 22391 34047 10997 12414 46461 % LAMP 8.2 16.3 44.8 68.1 22.0 24.8 92.9 % FIXT 8.9 17.5 48.2 73.3 23.7 26.7 100.0

TEST NO.: LUMINAIRE:

LAMP(S): EACH RATED: LINE POWER:

HP-06356 Tribay 2.0 Superwatt Finish: WHITE PAINT Optics: ALUMINUM ONE MVR-250/U 20,500 LUMENS 285 WATTS

ZONAL LUMEN SUMMARY


LUMENS 1743 3450 9612 13902 4722 5298 19200 % LAMP 8.5 16.8 46.9 67.8 23.0 25.8 93.7 % FIXT 9.1 18.0 50.1 72.4 24.6 27.6 100.0

TOTAL LUMINAIRE EFFICIENCY: 95.1% TOTAL REFLECTANCE OF PAINT: 91.9% SHIELDING ANGLE IN DEGREES: PARALLEL 0 NORMAL 0

SPACING CRITERION
0-DEG 2.3 90-DEG 2.3 BTWN 4 2.1

TOTAL LUMINAIRE EFFICIENCY: 92.9% TOTAL REFLECTANCE OF PAINT: 91.9% SHIELDING ANGLE IN DEGREES: PARALLEL 0 NORMAL 0

SPACING CRITERION
0-DEG 2.3 90-DEG 2.3 BTWN 4 2.1

TOTAL LUMINAIRE EFFICIENCY: 93.7% TOTAL REFLECTANCE OF PAINT: 91.9% SHIELDING ANGLE IN DEGREES: PARALLEL 0 NORMAL 0

SPACING CRITERION
0-DEG 2.3 90-DEG 2.3 BTWN 4 2.1

COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC RW 0 1 2 3 4 5 6 7 8 9 10 80 70 107 95 86 78 71 64 58 53 48 45 41 50 107 90 78 68 59 51 45 40 35 31 27 30 107 85 71 59 50 42 36 31 27 23 19 10 107 81 65 53 43 36 30 25 21 18 14 70 101 90 81 73 66 60 55 50 45 42 38 70 50 30 101 101 85 81 74 67 64 57 56 48 49 40 43 35 38 30 33 25 30 22 26 18 10 101 77 62 51 42 34 29 24 20 17 13 50 91 76 66 57 50 44 38 34 30 26 23 50 30 91 73 61 51 43 37 32 27 23 20 17 10 91 70 56 46 38 32 26 22 18 15 12 50 81 68 59 51 44 39 34 30 26 24 20 30 30 81 65 55 46 39 33 29 24 21 18 15 10 81 63 51 42 35 29 24 20 16 14 11 50 73 60 52 45 39 34 30 27 23 21 18 10 30 73 58 49 42 35 30 26 22 18 16 13 10 73 57 46 38 32 26 22 18 15 12 10 0 0 69 53 43 35 29 23 19 16 13 10 8

COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC RW 0 1 2 3 4 5 6 7 8 9 10 80 70 104 93 84 76 68 62 56 51 47 43 39 50 104 87 75 65 56 49 43 38 34 30 26 30 104 82 68 57 48 40 35 29 25 22 19 10 104 78 62 51 41 34 28 23 19 17 13 70 99 87 79 71 64 58 53 48 44 40 37 70 50 99 83 71 62 53 47 41 36 32 28 25 30 99 78 65 54 46 39 33 28 24 21 18 10 99 74 59 49 39 33 27 22 19 16 13 50 89 74 64 55 48 42 37 32 29 26 22 50 30 89 71 59 49 41 35 30 26 22 19 16 10 89 68 54 45 36 30 25 21 17 14 12 50 80 66 57 50 43 37 33 29 25 23 20 30 30 80 64 53 45 38 32 27 23 20 17 14 10 80 61 49 41 33 27 23 19 16 13 10 50 72 59 51 44 38 33 29 26 23 20 17 10 30 72 57 48 40 34 29 24 21 18 15 13 10 72 55 45 37 30 25 21 17 14 12 9 0 0 68 51 41 34 27 22 18 15 12 10 7

COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC RW 0 1 2 3 4 5 6 7 8 9 10 70 106 94 85 77 70 63 58 53 48 44 40 80 50 30 106 106 89 85 77 70 67 59 58 50 51 42 45 36 39 31 35 26 31 23 27 19 10 106 80 64 53 43 36 30 25 20 17 14 70 100 89 80 73 66 60 54 49 45 41 38 70 50 30 100 100 85 80 73 67 64 56 55 47 48 40 42 34 37 29 33 25 29 22 26 18 10 100 77 62 51 41 34 29 24 20 17 13 50 90 76 65 57 49 43 38 33 29 26 23 50 30 90 72 60 51 43 37 31 27 23 20 16 10 90 69 56 46 38 31 26 22 18 15 12 50 80 67 58 51 44 39 34 30 26 23 20 30 30 80 65 54 46 39 33 28 24 20 18 15 10 80 63 51 42 35 29 24 20 16 14 11 50 72 60 52 45 39 34 30 26 23 21 18 10 30 72 58 49 41 35 30 25 21 18 16 13 10 72 56 46 38 31 26 22 18 15 12 9 0 0 68 52 42 35 28 23 19 15 12 10 8

PHOTOMETRIC REPORT CAT. NO.: CH-25-H-x-x-LM


145 125 115 105 95

CANDELA DISTRIBUTION
0 5 15 25 35 45 55 65 75 85 90 95 105 115 125 135 145 155 165 175 180 3327 3353 3293 3520 3716 3805 4234 2426 1229 422 237 191 153 102 49 9 0 0 0 0 0

PHOTOMETRIC REPORT CAT. NO.: CH-40-S-x-x-LM


145 125 115 105 95

CANDELA DISTRIBUTION
0 5 15 25 35 45 55 65 75 85 90 95 105 115 125 135 145 155 165 175 180 7841 7770 7891 8406 8830 9181 10320 6058 3040 1040 584 466 373 252 125 27 0 0 0 0 0

PHOTOMETRIC REPORT CAT. NO.: CH-40-H-x-x-LM


145 125 115 105 95

CANDELA DISTRIBUTION
0 5 15 25 35 45 55 65 75 85 90 95 105 115 125 135 145 155 165 175 180 6010 6091 6013 6433 6824 6984 7655 4451 2242 768 432 345 277 185 93 21 0 0 0 0 0

85

85

85

V E R T I C A L LY

V E R T I C A L LY

150

75

300

75

270

0 0 0

75

0 200 250 0

65

500

65

360

450

65

300

0
55

0 350 0 400 450 0 0


0
25 35

700

0
55

540

0
55

900

0 6 30 0 720 810 0 0
25 HP-06283 Tribay 2.0 Controlux 00 180 Finish: WHITE PAINT Optics: PRISMATIC ACRYLIC REFLECTOR ONE MVR-400/U 36,000 LUMENS 460 WATTS 35

500
5 TEST NO.: LUMINAIRE:

45

110
5 15

00
25 35

45

900
5 15 TEST NO.: LUMINAIRE:

45

15 550

HP-06290 Tribay 2.0 Controlux 00 180 Finish: WHITE PAINT Optics: PRISMATIC ACRYLIC REFLECTOR ONE MVR-250/U 20,500 LUMENS 285 WATTS

ZONAL LUMEN SUMMARY


DEG ZONE 0-30 0-40 0-60 0-90 90-120 90-180 0-180 LUMENS 2890 5216 11969 16189 477 532 16721 % LAMP 14.1 25.4 58.4 79.0 2.3 2.6 81.6 % FIXT 17.3 31.2 71.6 96.8 2.9 3.2 100.0

TEST NO.: LUMINAIRE:

LAMP(S): EACH RATED: LINE POWER:

LAMP(S): EACH RATED: LINE POWER:

HP-06287 Tribay 2.0 Controlux Finish: WHITE PAINT Optics: PRISMATIC ACRYLIC REFLECTOR ONE C400S51 50,000 LUMENS 465 WATTS

ZONAL LUMEN SUMMARY


DEG ZONE 0-30 0-40 0-60 0-90 90-120 90-180 0-180 LUMENS 6877 12409 28742 39227 1166 1303 40530 % LAMP 13.8 24.8 57.5 78.5 2..3 2.6 81.1 % FIXT 17.0 30.6 70.9 96.8 2.9 3.2 100.0

V E R T I C A L LY
DEG ZONE 0-30 0-40 0-60 0-90 90-120 90-180 0-180

0 100

0 180

ZONAL LUMEN SUMMARY


LUMENS 5268 9535 21789 29468 864 969 30437 % LAMP 14.6 26.5 60.5 81.9 2.4 2.7 84.5 % FIXT 17.3 31.3 71.6 96.8 2.8 3.2 100.0

LAMP(S): EACH RATED: LINE POWER:

TOTAL LUMINAIRE EFFICIENCY: 81.6% TOTAL REFLECTANCE OF PAINT: XX% SHIELDING ANGLE IN DEGREES: PARALLEL X NORMAL X

SPACING CRITERION
0-DEG 1.7 90-DEG 1.7 BTWN 4 2.1

TOTAL LUMINAIRE EFFICIENCY: 81.1% TOTAL REFLECTANCE OF PAINT: XX% SHIELDING ANGLE IN DEGREES: PARALLEL X NORMAL X

SPACING CRITERION
0-DEG 1.7 90-DEG 1.7 BTWN 4 2.1

TOTAL LUMINAIRE EFFICIENCY: 84.5% TOTAL REFLECTANCE OF PAINT: XX% SHIELDING ANGLE IN DEGREES: PARALLEL X NORMAL X

SPACING CRITERION
0-DEG 1.7 90-DEG 1.7 BTWN 4 2.0

COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC RW 0 1 2 3 4 5 6 7 8 9 10 80 70 96 87 79 72 65 59 54 49 45 42 38 50 96 83 72 63 55 48 43 38 33 30 26 30 96 79 67 59 48 41 35 30 26 23 19 10 96 76 62 51 42 35 30 25 21 18 15 70 94 85 77 70 63 57 52 48 44 40 37 70 50 94 81 71 62 54 47 42 37 33 29 26 30 94 78 65 55 47 40 35 30 26 23 19 10 94 75 61 50 41 35 29 25 21 18 14 50 89 77 67 59 51 45 40 35 31 28 25 50 30 89 74 63 54 45 39 34 29 25 22 19 10 89 72 59 49 41 34 29 24 20 18 14 50 85 73 64 56 49 43 38 34 30 27 24 30 30 85 71 60 52 44 38 33 28 24 22 18 10 85 69 57 48 40 33 28 24 20 17 14 50 81 70 61 54 47 41 37 33 29 26 23 10 30 81 68 58 50 43 37 32 27 24 21 18 10 81 67 56 47 39 33 28 23 20 17 14 0 0 79 65 54 45 37 31 26 22 18 16 12

COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC RW 0 1 2 3 4 5 6 7 8 9 10 80 70 96 87 79 72 65 59 54 49 45 41 38 50 96 83 72 63 55 48 42 37 33 30 26 30 96 79 66 56 47 40 35 30 26 23 19 10 96 76 61 50 41 34 29 24 20 18 14 70 93 84 76 69 63 57 52 47 43 40 36 70 50 93 81 70 61 53 47 41 36 32 29 25 30 93 77 65 55 46 39 34 29 25 22 19 10 93 74 60 50 41 34 29 24 20 18 14 50 89 77 67 58 51 45 40 35 31 28 24 50 30 89 74 62 53 45 38 33 28 25 22 18 10 89 71 58 49 40 33 28 24 20 17 14 50 84 73 64 56 49 43 38 33 30 27 23 30 30 84 71 60 51 43 37 32 28 24 21 18 10 84 69 57 47 39 33 28 23 20 17 14 50 80 70 61 53 47 41 36 32 29 26 22 10 30 80 68 58 50 42 36 31 27 23 21 17 10 80 66 55 46 38 32 27 23 19 17 14 0 0 79 64 53 44 36 30 26 21 18 15 12

COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC RW 0 1 2 3 4 5 6 7 8 9 10 70 100 91 82 75 68 62 56 51 47 43 39 80 50 30 100 100 86 83 75 69 66 59 57 49 50 42 44 36 39 31 35 27 31 24 27 20 10 100 79 64 53 44 36 31 26 22 19 15 70 98 88 80 73 66 60 54 50 45 42 38 70 50 98 84 73 64 56 49 43 38 34 31 27 30 98 81 68 58 49 42 36 31 27 24 20 10 98 77 63 52 43 36 30 26 22 19 15 50 93 80 70 61 53 47 42 37 33 29 26 50 30 93 77 65 56 47 40 35 30 26 23 19 10 93 75 61 51 42 35 30 25 21 18 15 50 88 76 67 59 51 45 40 35 31 28 25 30 30 88 74 63 54 46 39 34 29 25 22 19 10 88 72 60 50 41 35 29 25 21 18 15 50 84 73 64 56 49 43 38 34 30 27 24 10 30 84 71 61 52 44 38 33 28 25 22 18 10 84 69 58 49 40 34 29 24 21 18 14 0 0 82 67 56 47 38 32 27 23 19 16 13

162

163

ADDITIONAL HUBBELL LIGHTING PRODUCTS

Precision Floodlighting

Floodlighting

Wall/Surface Lighting

Sports Lighting

Low Level Pedestrian

Area Lighting

Due to our continued efforts to improve our products, product specifications are subject to change without notice.

Alera Lighting Architectural Area Lighting Columbia Lighting Cornerstone Life Safety Products Devine Lighting Dual-Lite Hubbell Outdoor Lighting Hubbell Industrial Lighting Kim Lighting Moldcast Prescolite Progress Lighting Security Lighting Systems Spaulding Lighting Sterner Lighting Systems Sportsliter Solutions Whiteway
UNITED STATES Hubbell Lighting, Inc. 701 Millennium Boulevard Greenville, SC 29607 PHONE: 864-678-1000 CANADA Hubbell Canada 870 Brock Road Pickering, Ontario L1W 1Z8 www.hubbell-canada.com MEXICO Hubbell De Mexico, S.A. DE.CV Av. Coyoacan No. 1051 Col.Del Valle 03100 Mexico, D.F. www.hubbell.com.mx

For more information visit our web site: www.hubbell-ltg.com