SCAN FOR INSTALLATION VIDEOS
TECHNICAL DATA
ADAPTOR TYPE
INGRESS PROTECTION
: 783, 793
: IP66, IP67 & IP68 (when fitted with CMP sealing accessories) ASSEMBLY FITTING INSTRUCTIONS FOR
SERVICE TEMPERATURE : -60 to +200°C
PROCESS CONTROL SYSTEM
ISO/IEC 80079-34:2011
: ISO 9001 INTALLATION OF CMP Y AND T ADAPATOR
EXPLOSIVE ATMOSPHERES CLASSIFICATION TYPE 783(Y), 793(T)
ATEX CERTIFICATION No : CML 18ATEX1306U
ATEX CERTIFICATION CODE : ^ II 2G Ex db IIC Gb, Ex eb IIC Gb, II 1D Ex ta IIIC Da ^ I M2 Ex db I Mb, Ex eb I Mb INCORPORATING EU DECLARATION OF CONFORMITY TO DIRECTIVE 2014/34/EU
IECEx CERTIFICATION No : IECEx CML 18.0171U
IECEx CERTIFICATION CODE : Ex db I Mb, Ex eb I Mb, Ex db IIC Gb, Ex eb IIC Gb, Ex ta IIIC Da
IMPORTANT NOTES FOR INSTALLERS
1. Read all instructions before beginning installation. Installation shall only be performed by competent, suitably trained personnel (in accordance with EN/IEC 60079-14) using the correct tools;
spanners should be used for tightening.
2. Inspection and maintenance shall only be performed by competent, suitably trained personnel (in accordance with EN/IEC 60079-14 (Initial Inspection) and EN/IEC 60079-17).
3. The interface between a cable entry device and its associated enclosure / cable entry will require additional sealing to achieve ingress protection (IP) ratings higher than IP54. The minimum
protection level is IP54 for explosive gas atmospheres and IP6X for explosive dust atmospheres. Parallel threads (or tapered threads when using a non-threaded entry) require a CMP sealing washer
or integral O-ring face seal (where available) to maintain IP66, 67 and 68 (when applicable).
Note: When fitted to a threaded entry, all tapered threads will automatically provide an ingress protection rating of IP6X.
4. Adaptors are manufactured from Brass, Nickel Plated Brass, Stainless Steel or Mild Steel. The end user shall consider the performance of these materials with regard to attack by aggressive
substances that may be present in the hazardous area. Consideration should be given to potential degradation due to galvanic corrosion at the interface of dis-similar metallic materials.
5. It is the end user’s responsibility to ensure the equipment materials are suitable for their final installation location. If in doubt consult CMP Products Limited.
6. Ex db marked Adaptors can only be supplied with metric or NPT entry threads.
7. Equipment is not intended to be repaired. If damaged, equipment must be replaced.
8. A CMP earth tag should be used when it is necessary to provide an earth bond connection. CMP earth tags have been independently tested to comply with Category B rating specified in IEC 62444
(there are no ratings stated in IEC 60079-0). Ratings are shown in the associated table. CMP earth tags slip over the cable gland or accessory entry thread from inside the enclosure and must be
secured with a locknut.
SPECIAL CONDITIONS FOR SAFE USE
None
ORDERING
e.g. 783 - D - M - 2 - M - M - 2 - F - M - 2 - F - 5
= Dual Certified Ex d & Ex e - M20 (M) x M20 (F) x M20 (F) - Nickel Plated Brass
* Any combination of Male (M) / Female (F) threads is available e.g.
(M) X (M) X (M), (F) X (F) X (F), (M) X (F) X (M)
ACCESSORIES
The following accessories are available from CMP Products, as optional
extras, to assist with fixing, sealing and earthing:
Locknut | Earth Tag | Serrated Washer | Entry Thread (I.P.) Sealing Washer
Short Circuit Ratings
CMP Earth
Symmetrical Fault Current Product Selection Table
Tag Size
(kA) for 1 second Ordering Bore Thread 1*
Product Thread 2* Thread 3* Thread Length Protrusion Length ‘Y’ Protrusion Length ‘Z’ Width
20 3.06 Reference Diameter (Entry Thread)
25 4.06 793 793DM2MM2FM2F 14.7 M20 M20 M20 15.0 36.5 66.0 25 - 27
32 5.40 793 793DT1MT1FT1F 14.7 1/2” NPT 1/2” NPT 1/2” NPT 19.9 33.0 66.0 25 - 27
793 793DM3MM3FM3F 18.9 M25 M25 M25 15.0 45.0 70.5 30 - 32
793 793DT2MT2FT2F 18.9 3/4" NPT 3/4" NPT 3/4" NPT 20.2 40.0 70.5 30 - 32
793 793DM4MM4FM4F 25.9 M32 M32 M32 15.0 56.5 83.5 37 - 39
793 793DT3MT3FT3F 25.9 1" NPT 1" NPT 1" NPT 25.0 46.5 83.5 37 - 39
783 783DM2MM2FM2F 14.7 M20 M20 M20 15.0 48.0 73.0 25 - 27
783 783DT1MT1FT1F 14.7 1/2” NPT 1/2” NPT 1/2” NPT 19.9 43.0 73.0 25 - 27
CMP Products Limited on its sole responsibility declares that the equipment referred to herein conforms to the requirements of the ATEX Directive 2014/34/EU and the following 783 783DM3MM3FM3F 18.9 M25 M25 M25 15.0 48.0 76.9 30 - 32
standards:
783 783DT2MT2FT2F 18.9 3/4" NPT 3/4" NPT 3/4" NPT 20.2 48.0 76.9 30 - 32
- EN60079-0:2018, EN60079-1:2014, EN60079-7:2015, EN 60079-31:2013 783 783DM4MM4FM4F 25.9 M32 M32 M32 15.0 56.5 92.5 37 - 39
783 783DT3MT3FT3F 25.9 1" NPT 1" NPT 1" NPT 25.0 56.5 92.5 37 - 39
All dimensions shown are in millimetres unless otherwise stated
783 - Y ADAPTOR (Pictured)
David Willcock - Certification Engineer (Authorised Person) 793 - T ADAPTOR
CMP Products Limited, Cramlington, NE23 1WH
15 April 2019
FI516
Certification Revision Date
IFS 7 05/19
Glasshouse Street • St. Peters • Newcastle upon Tyne • NE6 1BS
ATEX / IECEx 6 04/19
2776
Tel: +44 191 265 7411 • Fax: +44 1670 715 646
E-Mail: customerservices@cmp-products.co.uk • Web: www.cmp-products.com
www.cmp-products.com
INSTALLATION INSTRUCTIONS FOR CMP ACCESSORY 783(Y), 793(T)
3. Attach further equipment / cable glands to remaining entries
Fitting instructions relevant for both Y and T adaptors
793 - T ADAPTOR 783 - Y ADAPTOR (Pictured)
1. Add entry thread seal if required
Tighten into enclosure / equipment by hand initially
Enclosure
Entry Thread
Seal
Enclosure
2. Complete tightening with spanner if necessary
NPT threads will lock before all threads are used
www.cmp-products.com www.cmp-products.com