0% found this document useful (0 votes)
126 views3 pages

Wire PDF

This test report summarizes the results of mechanical testing of zinc coated core wire for chain-link fencing. The wire was tested for breaking strength and coating thickness. The breaking strength test found an average of 6023 N, meeting the minimum requirement of 5740 N. Coating thickness measurements found an average of 0.59 mm, meeting the minimum requirement of 0.559 mm. All test results were in compliance with referenced standards ASTM A 370 / F 668 and MPW specifications.

Uploaded by

m.ali
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
126 views3 pages

Wire PDF

This test report summarizes the results of mechanical testing of zinc coated core wire for chain-link fencing. The wire was tested for breaking strength and coating thickness. The breaking strength test found an average of 6023 N, meeting the minimum requirement of 5740 N. Coating thickness measurements found an average of 0.59 mm, meeting the minimum requirement of 0.559 mm. All test results were in compliance with referenced standards ASTM A 370 / F 668 and MPW specifications.

Uploaded by

m.ali
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

NBTC-TS/FO-ML12 Rev.

01

Naser M. AL-Baddah & Partner General Trading & Contracting Co. W.l.l
Technical Services Division
MECHANICAL TESTING LABORATORY
Kuwait First ISO 17025 Accredited Laboratory
TEST REPORT - STRAND WIRE BREAKING STRENGTH
Report No. : TSD / MTR / 5222 Date : 30-Sep-2022 Date of Receipt : 28-Sep-2022
Customer Name
: CLIC National Industries - Kuwait Date of Test : 30-Sep-2022
& Address
Client : MPW - PART Lab No. : A 6329
Project Name : - Job Order No. : TSD / 22 / 2419
Project No. : - Material : ASTM F 668
Manufacturer : - Lab Temperature : 23.5ᵒ C
Description : Zinc Coated Core Wire Breaking Strength Test ( Chain-Link Fence Fabric )
REFERENCE
Equipment : Twin Screw Universal Testing Machine ( TSD-UTM-003) Calibration Certificate No. : F /011 /22

Equipment Sl.No. : 1182 Calibration Date : 25-Jan-2022

Make / Model : International Equipment / LSU - 13 Calibration Due Date : 24-Jan-2023

Ref.Std. / Spec. : ASTM A 370 / F 668 Procedure No. : NBTC-TS/ML-WI-01


TEST DETAILS
Sample ID T1 T2 T3 Average Requirements

Heat No. - - - - -

Coil No. - - - - -

Original Dia. ( mm ) 3.76 3.76 3.76 -

Measured Diameter ( mm ) 3.74 3.78 3.75 3.76 ± 0.13 mm

Length of Sample ( mm ) 200 200 200 200 -

Area of Wire ( mm² ) 11.0 11.2 11.0 11

Breaking Load ( kgf ) 615.5 619.2 608 614

Breaking Strength ( N ) 6035.6 6071.9 5962.0 6023 5740 ( Min. )

Breaking Location Out Side Wedges Out Side Wedges Out Side Wedges - -

Remarks : The test results are complies with above mentioned standards

Laboratory Witnessed By / Reviewed Client


Verified Authorized

Muhammad Ali Chatheri Snehal.M.Deshmukh

Head of Laboratory Technical Manager


Date: Date: Date:
Test results pertain to samples received at NBTC Lab.The test report shall note be reproduced except in full, without approval of the laboratory

Block - 5, Shuaiba Industrial Area -P.O.Box 9088,Ahmadi 61001 Kuwait


Tel:(+965) 1867777 Ext:4252/4262 Fax:(+965) 22284444 - E-mail:tech.services@nbtc-kuwait.com Web:www.nbtcgroup.com 1 of 1
NBTC-TS/FO-ML23 Rev.01

Naser M. AL-Baddah & Partner General Trading & Contracting Co. W.l.l
Technical Services Division
MECHANICAL TESTING LABORATORY
Kuwait First ISO 17025 Accredited Laboratory
TEST REPORT - COATING THICKNESS MEASUREMENT
Report No. : TSD / PCT / 0110 Date : 30-Sep-2022 Date of Receipt : 28-Sep-2022
Customer Name
: CLIC National Industries - Kuwait Date of Test : 30-Sep-2022
& Address
Client : MPW - PART Lab No. : A 6329

Project Name : - Job Order No. : TSD/ 22 / 2419


3.76 mm Ø
Project No. : - Size :
( Without Coating )
Material : ASTM F 668 Heat No. : -

Manufacturer : - Lab Temperature : 24ᵒ C

Description : PVC Coating Thickness Measurement Zinc and PVC Coated Core Wire ( Chain-Link Fence Fabric )
REFERENCE
Equipment : Coating Thickness Gauge Calibration Certificate No. : 22/07/2003/268996

Equipment Sl.No. : P 21602 ( Gauge ) / 337048 (Probe ) Calibration Date : 29-Jul-2022

Make / Model : Posi Tector STD 6000 Calibration Due Date : 28-Jul-2023

Ref.Std. / Spec. : MPW ( Road ) Procedure No. : -

MEASUREMENT DETAILS
Measured Readings in mm
Sl.No. Description Location / Sample -
1 2 3 4 5 Average

Zinc And PVC Coated


1 Wire 0.60 0.58 0.61 0.57 0.58 0.59 -
Core Wire

Requirements : Asper MPW - 0.559 mm (Min.)


Remarks : The test results Complies with above mentioned Standards

Laboratory Witnessed / Reviewed By Client


Verified Authorized

Muhammad Ali.C Snehal.M.Deshmukh

Head of Laboratory Technical Manager


Date: Date: Date:
Test results pertain to samples received at NBTC Lab.The test report shall note be reproduced except in full, without approval of the laboratory

Block - 5, Shuaiba Industrial Area -P.O.Box 9088,Ahmadi 61001 Kuwait


Tel:(+965) 1867777 Ext:4252/4262 Fax:(+965) 22284444 - E-mail:tech.services@nbtc-kuwait.com Web:www.nbtcgroup.com 1 of 1
NBTC-TS/FO-ML23 Rev.01

Naser M. AL-Baddah & Partner General Trading & Contracting Co. W.l.l
Technical Services Division
MECHANICAL TESTING LABORATORY
Kuwait First ISO 17025 Accredited Laboratory
TEST REPORT - COATING THICKNESS MEASUREMENT
Report No. : TSD / GVT / 331 Date : 30-Sep-2022 Date of Receipt : 28-Sep-2022
Customer Name
: CLIC National Industries - Kuwait Date of Test : 30-Sep-2022
& Address
Client : MPW - PART Lab No. : A 6329

Project Name : - Job Order No. : TSD/ 22 / 2419

Project No. : - Size : 3.76 mm Ø

Material : ASTM F 668 Heat No. : -

Manufacturer : - Lab Temperature : 24ᵒ C

Description : Zinc Coating Weight Measurement of Zinc Coated Core Wire ( Chain-Link Fence Fabric )
REFERENCE
Equipment : Digital Balance Calibration Certificate No. : M / 743 / 21

Equipment Sl.No. : 8728314565 Calibration Date : 25-Nov-2021

Make / Model : AV 8101 / Ohaus Calibration Due Date : 24-Nov-2022

Ref.Std. / Spec. : ASTM A 90 / F 668 Procedure No. : -

MEASUREMENT DETAILS
Weight ( Mass )
Initial Weight Weight After Weight of Zinc Average
Sl.No. Description of Coating
( gm ) Stripping ( gm ) ( gm ) ( g/m² )
( g/m² )

1 17.60 17.35 0.25 106.19

3.76 mm Dia Wire 200 mm Length


2 17.67 17.42 0.25 105.76 108.9
Cut Piece

3 17.62 17.35 0.27 114.69

Requirements : Asper ASTM F 668 - 92 g/m² ( Min. )


Remarks : The test results Complies with above mentioned Standards

Laboratory Witnessed / Reviewed By Client


Verified Authorized

Muhammad Ali.C Snehal.M.Deshmukh

Head of Laboratory Technical Manager


Date: Date: Date:
Test results pertain to samples received at NBTC Lab.The test report shall note be reproduced except in full, without approval of the laboratory

Block - 5, Shuaiba Industrial Area -P.O.Box 9088,Ahmadi 61001 Kuwait


Tel:(+965) 1867777 Ext:4252/4262 Fax:(+965) 22284444 - E-mail:tech.services@nbtc-kuwait.com Web:www.nbtcgroup.com 1 of 1