0% found this document useful (0 votes)
719 views1 page

Bay Section Structural

The document describes a steel roof structure with the following components: prefabricated skylight, aluminum ceiling panel, steel truss support, and aluminum secondary roof framing. It also describes the use of plywood, rigid insulation, an aerogation container and nozzles, stainless steel cable, and a glass panel for the roof structure. Below the roof, the document outlines the concrete slab foundation and reinforcement details including rebar sizes, stirrup spacing, stud connectors, and anchorage bolts.

Uploaded by

Paulo Amoroso
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
719 views1 page

Bay Section Structural

The document describes a steel roof structure with the following components: prefabricated skylight, aluminum ceiling panel, steel truss support, and aluminum secondary roof framing. It also describes the use of plywood, rigid insulation, an aerogation container and nozzles, stainless steel cable, and a glass panel for the roof structure. Below the roof, the document outlines the concrete slab foundation and reinforcement details including rebar sizes, stirrup spacing, stud connectors, and anchorage bolts.

Uploaded by

Paulo Amoroso
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

STEEL ROOF FRAMING

PREFABRICATED SKYLIGHT

ALUMINUM CEILING PANEL

STEEL TRUSS SUPPORT

ALUMINUM SECONDARY
ROOF FRAMING

3
16" x 2 21 " S.S. SCREW, 150 lb
TEAR STRENGTH MIN. 12" O.C.
1
2 " CDX PLYWOOD

1
2 " RIGID INSULATION

AEROGATION CONTAINER
COMPOSED OF HIGH DENSITY
POLY PROPYLENE (HDPE)

AEROGATION NOZZLES:
COMPOSED OF ABS MATERIAL,
WITH FIBER GLASS WICK

SS CABLE

GLASS PANEL

NODE ASSEMBLY

8 NOS. 16 MM DIA. BARS COLUMN


REINFORCEMENT
8 MM DIA. STIRRUPS
@ 200 C/C
8 MM DIA. STIRRUPS
@ 200 C/C
CONCRETE SLAB

NOMINAL REINFORCEMENT
STUD SHEAR CONNECTOR

COLD-FORMED STEEL DECK

CONCRETE SLAB

NOMINAL REINFORCEMENT

8 MM DIA. STIRRUPS
@ 200 C/C

STUD SHEAR CONNECTOR

COLD-FORMED STEEL DECK

CONCRETE SLAB
NOMINAL REINFORCEMENT

NOMINAL REINFORCEMENT
CAGE OF 12 MM DIA. BARS
BOTHWAYS
COMPACT EARTH

16 MM DIA. BARS MAIN


REINFORCEMENT
16 ANCHORAGE BOLTS
Ø1 1/4 "x150cm SAE 1045
NUT OF LEVELING

15 Ø MM P.C.C BED WITH WATER


PROOFING TREATMENT

PILES

STRUCTURAL BAY SECTION


SCALE: 1:175 M

You might also like