Communication
Industrial and Commercial
CU-P40, P41, P42
E65C
Technical Data
E65C CU-P40, P41, P42 communication units provide
GSM/GPRS communication between E650 or E850 meters and a central system.
Date: 15.03.2012
File name: D000043188 E65C CU-P4x Technical Data en.docx
© Landis+Gyr D000043185 en a
2/6
Revision history
Version Date Comments
a 15.03.2012 First edition (derived from technical data E65C CU-P30, P31, P32 D000011687)
Nothing in this document shall be construed as a representation or guarantee in respect of the performance, quality or durability of the
specified product. Landis+Gyr accepts no liability whatsoever in respect of the specified product under or in relation to this document.
Subject to change without notice.
© Landis+Gyr D000043185 en a – E65C – CU-P40, P41, P42 – Technical Data
3/6
E65C CU-P40, P41, P42 – Technical specifications
Design GSM/GPRS module
Type Survey Type Telit GE865-QUAD
Type GSM/GPRS RS232 RS485 CS+ Frequency bands
Modem quad-band 850, 900, 1800 and 1900 MHz
Output power
CU-P40
- 2 W/class 4 at GSM 850 MHz
CU-P41 - 2 W/class 4 at EGSM 900 MHz
CU-P42 - 1 W/class 1 at GSM 1800 MHz
- 1 W/class 1 at GSM 1900 MHz
Supported communication protocols
SIM-card
- IEC 62056-21 and dlms
SIM 1.8/3 V exchangeable from outside
- TCP/IP
- IPT (according to DIN 43863)
RS232 interface
Fitting Only present on type CU-P41
Directly in meter (E650 ZxD300/400xT or E850 ZxQ) Asymmetric, serial, asynchronous, bi-directional
In CU adapter CU-ADP2 (for other meters) interface (3-wire design)
Standard EIA RS232-C/CCITT V.24
Features Maximum transmission rate 57,600 bps
- EMC conformance for meter and modem together Maximum line length 15 m
for electrical metering equipment and industrial
environments
- Two independent channels to access meter
RS485 interface
- Configuration without additional software tools Only present on type CU-P42
other than MAP Symmetric, serial, asynchr., bi-directional interface
- Configuration using only an optical head. (master or slave depending on parameterisation)
- Remote upgradable firmware for the micro- Standard ISO-8482
controller Maximum number of slaves 31
- Large 10 kByte buffer to enable IEC readouts of Maximum transmission rate 57,600 bps
serial attached meter(s) at transmission rates of up Maximum line length
to 19,200 bps - up to 250 m at max. 57,600 bps, max. 31 Slaves
- Password protection system for parameters - up to 550 m at max. 38,400 bps, max. 31 Slaves
- up to 1000 m at max. 19,200 bps, max. 15 Slaves
Power consumption
Maximum active/apparent power 3.0 W/5.5 VA CS interface
Only present on types CU-P41 and CU-P42
GSM/GPRS Modem Serial, bi-directional current interface
Operating modes GSM or GPRS active or passive
Standards and approvals Standard IEC 62056-21/DIN 66258
- ETSI EN 301 511 V9.0.2 Maximum number of slaves 4
- 3GPP Release 4 compliant Maximum transmission rate 19,200 bps
- Full GCF and PTCRB approvals
- GPRS class 8 (recommended), 10 (maximum) LED displays
LEDs RX and TX
Functions Indication of data flow and field strength level
Time window and time master functions
SMS-forwarding of alarm messages LED CON
(only if fitted in meter) Indication of connection status and number of base
Modem initialization and data flow control stations received
Automatic modem reset
Communication monitoring LED GSM
Receive CSD while listening in GPRS mode Indication of GSM data transfer or CSD call setup
D000043185 en a – E65C – CU-P40, P41, P42 – Technical Data © Landis+Gyr
4/6
Environmental influences RS232 or RS485 interface RJ12 socket
Temperature range to IEC 62052-11 Pin allocation: RS232: RS485:
Operation -40 C to +70 C 1 not used 1 GND
2 TxD 2 UP (Data a)
Storage -40 C to +85 C 3 GND 3 UN (Data b)
4 not used 4 UN (Data b)
Insulation strength to meter 5 RxD 5 UP (Data a)
6 not used 6 GND
Insulation strength 4 kV at 50 Hz for 1 min 6 1
Insulation spacing at least 6.3 mm
Material
Weight and dimensions Case polycarbonate
Weight approx. 100 g
Connection diagram
Width / Height / Depth 65 / 103 / 38 mm
Example CU-P41
Connections
Connection to meter or CU adapter
10-pin connector at rear of CU
External 5 V power supply (only for E650 meters)
2-pin connector; recommended for a reliable modem
operation for M circuits and the supply voltage
phase – neutral is 58 V nominal and 64 V nominal
where there is only one phase present.
Landis+Gyr should be consulted if supply voltage is
between 100 V nominal and 115 V nominal where Example CU-P42
there are only one or two phases present.
The statements above apply to E650 series 3
meters (firmware version B31 or higher).
Information on previous versions can be found in the
user manual.
CS interface screwless spring-type terminals
Antenna connection MCX socket
Tear-off strength < 390 N
Terminal layout
+ –
RS232 (CU-P41 only)
RS485 (CU-P42 only)
Antenna connection
CS (CU-P41 and CU-P42 only)
External 5 V power supply
© Landis+Gyr D000043185 en a – E65C – CU-P40, P41, P42 – Technical Data
5/6