Toroidal Transformers Standard Range: Type RT

The document describes toroidal transformers, which are single-phase safety isolating transformers designed for electronics equipment. They have separate insulated windings, thermal fuse protection, and weigh up to 50% less than conventional transformers. They are suitable for applications where low weight, flexible dimensions, and optimal space conditions are required. The document provides specifications, dimensions, and power ratings for standard toroidal transformer models in the range of 20 to 300VA.

Uploaded by

prasad
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
214 views2 pages

Toroidal Transformers Standard Range: Type RT

The document describes toroidal transformers, which are single-phase safety isolating transformers designed for electronics equipment. They have separate insulated windings, thermal fuse protection, and weigh up to 50% less than conventional transformers. They are suitable for applications where low weight, flexible dimensions, and optimal space conditions are required. The document provides specifications, dimensions, and power ratings for standard toroidal transformer models in the range of 20 to 300VA.

Uploaded by

prasad
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Toroidal transformers

Toroidal transformers standard range


Type RT
Single-phase toroidal transformers, power range from
20 to 300VA. Designed and tested according to EN61558.
Suitable for installation in electronically equipment.
Designed as a safety isolating transformer with separate
insulated windings and prepared for class II equipment.
Short circuit and overload protected with thermal fuse
on primary side. Up to 50% less weight than a similar
conventional transformer. Low magnetisation currents
and no-load losses.

Applications: Wiring diagram


Suitable as safety isolating transformer in constructions
where low weight, flexible dimensions and optimum
conditions between dimensions are preferable.

Technical specifications

Input voltage: 230V

Frequency: 50-60Hz

Output voltage: max 2x45V Dimensions


According to: EN61558

Test/insulating voltage: 4kV AC RMS

Construction class: II

Insulation class: B (130°C)

Ambient temp. (ta): 40°C

Degree of protection: IP00

Supplied with rubber pads and metal washer

Dimensions
Power Cu-loss Fe-loss Ø ext. Ø inner Height Weight
Type
(VA) (W) (W) A (mm) G (mm) C (mm) (Kg)
RT020 20 5,6 0,3 63 19 28 0,3
RT050 50 8,7 0,6 72 26 40 0,6
RT080 80 13,7 0,9 78 26 47 0,9
RT100 100 16,9 1,1 92 34 48 1,1
RT120 120 18,3 1,4 89 36 52 1,4
RT160 160 23,4 1,8 99 36 52 1,8
RT200 200 24,1 2,1 108 36 52 2,1
RT250 250 25,3 2,3 110 38 60 2,3
RT300 300 28,7 2,7 112 38 66 2,7

6-2 www.noratel.com
Standardmodels
Voltage Current Power Voltage Current Power
Type Art. no. Type Art. no.
Sec. (V) Sec. (A) (VA) Sec. (V) Sec. (A) (VA)
230/2x6 V 230/2x24 V
RT020-2006 2x6 2x1,67 20 4-115-020206 RT020-2024 2x24 2x0,42 20 4-115-102224
RT050-2006 2x6 2x4,17 50 4-115-150206 RT050-2024 2x24 2x1,04 50 4-115-105224
RT080-2006 2x6 2x6,67 80 4-115-108206 RT080-2024 2x24 2x1,67 80 4-115-108224
230/2x10 V RT120-2024 2x24 2x2,5 120 4-115-112224
RT020-2010 2x10 2x1,0 20 4-115-102210 RT160-2024 2x24 2x3,33 160 4-115-116224
RT050-2010 2x10 2x2,5 50 4-115-105210 RT200-2024 2x24 2x4,17 200 4-115-120224
RT080-2010 2x10 2x4,0 80 4-115-108210 RT250-2024 2x24 2x5,21 250 4-115-125224
RT120-2010 2x10 2x6,0 120 4-115-112210 RT300-2024 2x24 2x6,25 300 4-115-130224

230/11,5 V 230/2x30 V
RT020-1011* 11,5 1,74 20 4-116-102111 RT080-2030 2x30 2x1,33 80 4-115-108230
RT050-1011* 11.5 4,35 50 4-116-105111 RT120-2030 2x30 2x2,0 120 4-115-112230
RT100-1011* 11,5 8,7 100 4-116-110111 RT160-2030 2x30 2x2,67 160 4-115-116230
RT250-2030 2x30 2x4,17 250 4-115-125230
230/2x12 V
RT020-2012 2x12 2x0,83 20 4-115-102212 230/2x33 V
RT050-2012 2x12 2x2,08 50 4-115-105212 RT300-2033 2x33 2x4,55 300 4-115-130233
RT080-2012 2x12 2x3,33 80 4-115-108212 230/2x35 V
RT120-2012 2x12 2x5,0 120 4-115-112212 RT120-2035 2x35 2x1,71 120 4-115-112235
RT160-2012 2x12 2x6,67 160 4-115-116212 RT160-2035 2x35 2x2,29 160 4-115-116235
230/2x15 V RT200-2035 2x35 2x2,78 200 4-115-120235
RT020-2015 2x15 2x0,67 20 4-115-102215 230/2x38 V
RT050-2015 2x15 2x1,67 50 4-115-105215 RT250-2038 2x38 2x3,29 250 4-115-125238
RT080-2015 2x15 2x2,67 80 4-115-108215 RT300-2038 2x38 2x3,95 300 4-115-130238
RT120-2015 2x15 2x4,0 120 4-115-112215 230/2x40 V
RT160-2015 2x15 2x5,33 160 4-115-116215 RT160-2040 2x40 2x2,0 160 4-115-116240
RT200-2015 2x15 2x6,67 200 4-115-120215
230/2x42 V
230/2x18 V RT200-2042 2x42 2x2,38 200 4-115-120242
RT020-2018 2x18 2x0,56 20 4-115-102218 RT250-2042 2x42 2x2,98 250 4-115-125242
RT050-2018 2x18 2x1,39 50 4-115-105218 RT300-2042 2x42 2x3,57 300 4-115-130242
RT080-2018 2x18 2x2,22 80 4-115-108218
230/2x45 V
RT120-2018 2x18 2x3,33 120 4-115-112218
RT160-2045 2x45 2x1,78 160 4-115-116245
RT160-2018 2x18 2x4,44 160 4-115-116218
RT200-2018 2x18 2x5,55 200 4-115-120218
RT250-2018 2x18 2x6,94 250 4-115-125218
RT300-2018 2x18 2x8,33 300 4-115-130218
*Termoswitch, ta= 60°C /B

230/2x22 V
Toroidal transformers with 2 secondary voltages can
RT050-2022 2x22 2x1,14 50 4-115-105222 be used as separate series- or parallel connected.
RT080-2022 2x22 2x1,82 80 4-115-108222
RT120-2022 2x22 2x2,73 120 4-115-112222 Standard types can be supplied with potted centre
RT160-2022 2x22 2x3,64 160 4-115-116222 hole (RTD) or potted in polyamid housings (RTV).

www.noratel.com 6-3