0% found this document useful (0 votes)
266 views2 pages

1 3kva Rack

This document describes an online UPS system with 1000-3000VA capacity that is rack mountable and has a 1:1 phase and 0.9 power factor. It has an LCD display and features online double conversion, a wide input voltage range, high input and output power factors, optional communication ports, and smart battery charging. It can support lithium batteries and has selectable output voltages, low priority load disconnection, and an optional battery cabinet.

Uploaded by

Babamkwe
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
266 views2 pages

1 3kva Rack

This document describes an online UPS system with 1000-3000VA capacity that is rack mountable and has a 1:1 phase and 0.9 power factor. It has an LCD display and features online double conversion, a wide input voltage range, high input and output power factors, optional communication ports, and smart battery charging. It can support lithium batteries and has selectable output voltages, low priority load disconnection, and an optional battery cabinet.

Uploaded by

Babamkwe
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Online UPS

1000 - 3000 VA
RACK MOUNTABLE

1:1 Phase
PF 0.9

LCD display

Features
• Online double conversion
• Wide input voltage range (110 ~ 300 Vac)
• Input power factor: 0.99 (With PFC)
• Output power factor: 1.0
Relay card • Optional charging current either 1A or 2A
(2A charging current for two groups of installed batteries)
• 50 Hz / 60 Hz frequency converter mode
• Emergency power off function (EPO)
• ECO mode support
• Generator compatible
• Optional Communication ports: SNMP, USB, RS232
• Smart battery charging design for
SNMP card Parallel card optimized battery performance
• Supports lithium batteries and BMS
• Selectable output voltage: 200, 208, 220, 230, 240 Vac
• Low priority load disconnection function

Back Rotating LCD Optional battery cabinet


7
MODEL EP-UPS1000UC13OR EP-UPS2000UC13OR EP-UPS3000UC13OR
Capacity (VA / Watts) 1000 VA / 1000 W 2000 VA / 2000 W 3000 VA / 3000 W
Phase Single phase with ground
INPUT
Nominal Voltage 200 / 208 / 220 / 230 / 240 Vac
Low voltage of 160 Vac ± 5 % @ 100 % ~ 80 % load, 120 Vac ± 5 % @ 70 % ~ 60 % load,
transferring to bypass 110 Vac ± 5 % @ 60 % ~ 50 % load (Ambient temp. < 35 °C)

Low threshold voltage 175 Vac ± 5 % @ 100 % ~ 80 % load, 135 Vac ± 5 % @ 70 % ~ 60 % load,
of recovering from bypass 125 Vac ± 5 % @ 60 % ~ 50 % load (Ambient temp. < 35 °C)
Operating Voltage Range
High voltage
300 Vac ± 5 %
of transferring to bypass

High threshold voltage


290 Vac ± 5 %
of recovering from bypass
Input Voltage Range 55 ~ 150 Vac or 110 ~ 300 Vac @ 60 % load, 80 ~ 145 Vac or 160 ~ 300 Vac @ 100 % load
Operating frequency range 40 ~ 70 Hz
Power Factor 0.99
Generator input Supported
OUTPUT
Output Voltage 200 / 208 / 220 / 230 / 240 Vac
Power Factor 1
Voltage regulation ±1%
Line mode (synchronized range) 47 ~ 53 Hz or 57 ~ 63 Hz
Frequency
Bat. mode 50 / 60 Hz ±1 Hz
Crest Factor 3:1
≤ 2 % THD (Linear load)
Harmonic Distortion (THDv)
≤ 4 % THD (Non-linear load)
Waveform Pure Sinewave
AC mode <-> batt. mode Zero
Transfer time
Inverter <-> bypass 4 ms (Typical)
EFFICIENCY
AC Mode 88 % 92 % 92 %
Battery mode 85 % 88 % 90 %
BATTERY
Battery type 12 V 9 Ah
Number of batteries 2 4 6
Typical recharge time 4 hours charge to 90 % capacity
Charging voltage 27.4 Vdc ± 1 % 54.7 Vdc ± 1 % 82.1 Vdc ± 1 %
Charging current (max) 1 A or 2 A
SYSTEM FEATURES
105 % ~ 110 %: UPS will transfer to bypass mode within 10 min of return of utility power
110 % ~ 130 %: UPS will transfer to bypass mode within 1 min of return of utility power
AC mode Ambient temp. < 35 °C
130 % ~ 150 %: UPS will transfer to bypass mode within 5 sec of return of utility power
> 150 %: UPS will transfer to bypass mode immediately upon return of utility power
105 % ~ 110 %: UPS will transfer to bypass mode within 1 min of return of utility power
Battery mode 35 °C < ambient temp. < 40 °C 110 % ~ 130 %: UPS will transfer to bypass mode within 5 sec of return of utility power
> 130 %: UPS will transfer to bypass mode immediately upon return of utility power
Short circuit Hold whole system
Overheat Line mode: Switch to bypass. Backup mode: UPS will sut down immediately
Battery low Alarm and switch off
EPO (optional) Shut down UPS imediately
Audible & visual alarms Line failure, battery low, over load, system fault
MANAGEMENT
Communication ports USB, RS232, SNMP card(optional), Relay card(optional)
OPERATING ENVIRONMENT
Operating temperature 0 ~ 40 °C
Storage temperature -25 °C ~ 55 °C
Humidity range 20 ~ 90 % RH @ 0 ~ 40 °C (Non-condensing)
Recommended altitude < 1500 m
Noise level Less than 50 dBA at 1 m
PHYSICAL FEATURES
Dimensions (W * D * H) mm 440 * 325 * 86.5 440 * 460 * 86.5 440 * 600 * 86.5
Approx. net weight (kg) 11.3 19.1 26.2