GENERIC DESIGN OF PLUMBING SYSTEM
FOR RESTAURANT TYPE OF TENANT
1.2 KW POWER REQMT.
50 LTS. CAPACITY
EWH
1.2 KW POWER REQMT.
50 LTS. CAPACITY
EWH
1.2 KW POWER REQMT.
50 LTS. CAPACITY
EWH
1.2 KW POWER REQMT.
50 LTS. CAPACITY
EWH
SCHEDULE FOR ELECTRIC WATER HEATERS
CAPACITY POWER SUPPLY QTY.
TAG NO UNIT DESCRIPTION DESCRIPTION
NOTES :
DESIGN OF WATER SUPPLY SYSTEM
· SIZING IS BASED ON IPC (INTERNATIONAL PLUMBING CODE).
· RECOMMENDED PIPING MATERIAL - PPR (POLY-PROPYLENE RANDOM)
· THE CONTRACTOR SHALL ENSURE THE DROPS IN WALL PRIOR TO SANITARY FIXTURE
SHALL ADHERE TO THE REQUIREMENT OF THE FIXTURE.
· WHA (WATER HAMMER ARRESTOR) LOCATION IS INDICATIVE & SHALL BE STUDIED
UPON WITH REFERENCE TO PDI (PLUMBING DRAINAGE INSTITUTE) GUIDELINES FOR
DECIDING THE LOCATION FOR OPTIMUM PERFORMANCE.
· IN CASE INDIVIDUAL WATER HEATERS ARE RELOCATED, IT MAY AFFECT THE PIPE
ROUTING & HENCE THE PIPE SIZING. SUCH IMPACT SHALL BE TAKEN INTO
CONSIDERATION BY THE CONTRACTOR.
FCO FCO
INTERCEPTOR
INTERCEPTOR
GREASE
GREASE
FD
FD
REQUIREMENT OF DRAINAGE SYSTEM
· THERE ARE 2 TYPES OF PIPES IN THE DRAINAGE SERVICES AS FOLLOW
'SP' - SOIL PIPING
'WP' - WASTE PIPING
· DRAINAGE FIXTURES USED ARE
'FD' - FLOOR DRAIN
'FCO' - FLOOR CLEAN-OUT
'SGD' - SQUARE GRATING DRAIN
· PIPE & FITTINGS SHALL BE OF PVC SCH. 40/CLASS 4 TYPE MATERIAL; APPROVED BY
SASO.
· ALL ABOVE GROUND PIPES SHALL HAVE SOLVENT WELD TYPE INSTALLATION.
· SANITARY FIXTURE SHALL BE STUDIED UPON FOR RECOMMENDED PIPING
CONNECTION THAT FURTHER ADVANCES TO THE MAIN PIPING.
· EMBEDDED PIPING EXECUTION SHALL NOT HOLD TRUE WITHOUT THE APPROVAL OF
CIVIL ENGINEERING DISCIPLINE ON BASIS OF APPROVED BUILDER WORK'S DRAWINGS.
· THE SYSTEM ASSUMES WALL HUNG TYPE WESTERN WATER CLOSET. IT SHALL BE
THOROUGHLY STUDIED FOR THE CARRIER DETAILS & CONNECTIONS.
· CONDENSATE DRAIN FROM THE A/C EQPTS. MUST BE EQUIPPED WITH VENTED TRAP &
FURTHER TO BE CONNECTED TO THE SITE CONDENSATE DRAINAGE NETWORK.