0% found this document useful (0 votes)
52 views3 pages

Rele He

StandexMeder is a global leader in sensor and magnetic component design and manufacturing. This datasheet provides information on StandexMeder's HE Series reed relays, including features, applications, markets served, product descriptions, specifications, environmental requirements, handling instructions, and a glossary. The HE reed relays offer a compact design and high voltage options for applications in medical equipment, test and measurement, and other industries.

Uploaded by

Pavel Križnar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
52 views3 pages

Rele He

StandexMeder is a global leader in sensor and magnetic component design and manufacturing. This datasheet provides information on StandexMeder's HE Series reed relays, including features, applications, markets served, product descriptions, specifications, environmental requirements, handling instructions, and a glossary. The HE reed relays offer a compact design and high voltage options for applications in medical equipment, test and measurement, and other industries.

Uploaded by

Pavel Križnar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

A Global Leader in the Design, Development, and

Manufacture of Sensor and Magnetic Components

Series Datasheet – HE Reed Relays www.standexmeder.com

HE Series
Reed Relays

 Features: High Voltage Relay, Through-Hole / Axial Wire Option, Compact Design, Special Pin-Outs
 Applications: High Voltage Test Sets, Cable Testers, Medical Equipment & Others
 Markets: Medical, Test and Measurement & Others

Part Description: HE 00-0X-00-00

Nominal Voltage Contact QTY Contact Form Switch Model Pin Out
05, 06, 12, 24, 48 1, 2 A, B 69, 83 02, 03, 150, 300

Customer Options Switch Model


Unit
Contact Data 69 83
Rated Power (max.) 50 50 W
Any DC combination of V&A not to exceed their individual max.’s
Switching Voltage (max.) 10,000 7,500 V
DC or peak AC
Switching Current (max.) 3.0 3.0 A
DC or peak AC
Carry Current (max.) 5.0 5.0 A
DC or peak AC
Contact Resistance (max.) 150 150 mOhm
@ 0.5V & 50mA
Breakdown Voltage (min.) 15 10 kVDC
According to EN60255-5
Operating Time (max.) 3.0 3.0 ms
Incl. Bounce; Measured with w/ Nominal Voltage
Release Time (max.) 1.5 1.5 ms
Measured with no Coil Excitation
Insulation Resistance (typ.) 1012 1012 Ohm
Rh<45%, 100V Test Voltage
Capacitance (typ.) 0.2 0.2 pF
@ 10kHz across open Switch

USA: +1.866.782.6339 │ salesusa@standexmeder.com Version 01


Europe: +49.7731.8399.0 │ info@standexmeder.com 27.01.2015
Asia: +86.21.37820625 │ salesasia@standexmeder.com

Modifications in the sense of technical progress are reserved.


A Global Leader in the Design, Development, and
Manufacture of Sensor and Magnetic Components

Series Datasheet – HE Reed Relays www.standexmeder.com

Coil Data
Coil Voltage Coil Resistance Pull-In Voltage Drop-Out Voltage Nominal Coil Power
Contact Switch (nom.) (typ.) (max.) (min.) (typ.)
Form Model
Unit VDC Ohm VDC VDC mW
12 110 9 1 1,310
69
24 465 18 2 1,240
1A
12 260 9 1 554
83
24 1050 18 2 554
12 260 9 1 554
69
24 1,050 18 2 548
1B*
12 410 9 1 351
83
24 1,520 18 2 378
2A 83 12 140 9 1 1,000
The Pull-In / Drop-Out Voltage and Coil Resistance will change at rate of 0.4% per °C.
* Re-closure of Form B may occur if the max. coil voltage is exceeded. Coil polarity on Form B must be observed. Pin 2 is positive.

Environmental Data Unit HE Reed Relay


Shock Resistance (max.) 50 g
1/2 sine wave duration 11ms
Vibration Resistance (max.) 20 g
Operating Temperature -20 to 70 °C
Storage Temperature -35 to 105 °C
Soldering Temperature (max.)
260 °C
5 sec. max.

Handling & Assembly Instructions


 Switching inductive and/or capacitive loads create voltage
and/or current peaks, which may damage the relay.
Protective circuits need to be used. Life Test Data
 External magnetic fields needs to be taken into *Load increase reduces life expectancy of Reed Switches
consideration, including a too high packing density. This may
influence the relays’ electrical characteristics.
 Mechanical shock impacts e.g. dropping the relays may cause
immediate or post-installation failure.
 Wave soldering: maximum 260°/5 seconds.
 Reflow soldering: Recommendations given by the soldering
paste manufacturer need to be considered as well as the
temperature limits of other components/processes.

USA: +1.866.782.6339 │ salesusa@standexmeder.com Version 01


Europe: +49.7731.8399.0 │ info@standexmeder.com 27.01.2015
Asia: +86.21.37820625 │ salesasia@standexmeder.com

Modifications in the sense of technical progress are reserved.


A Global Leader in the Design, Development, and
Manufacture of Sensor and Magnetic Components

Series Datasheet – HE Reed Relays www.standexmeder.com

Glossary Contact Form


NO = Normally Open Contacts
Form A
SPST = Single Pole Single Throw

NC = Normally Closed Contacts


Form B
SPST = Single Pole Single Throw
Changeover
Form C
SPDT = Single Pole Double Throw

Pin Outs
Dimensions available in Product Datasheets.

USA: +1.866.782.6339 │ salesusa@standexmeder.com Version 01


Europe: +49.7731.8399.0 │ info@standexmeder.com 27.01.2015
Asia: +86.21.37820625 │ salesasia@standexmeder.com

Modifications in the sense of technical progress are reserved.