INSTALLATION INSTRUCTIONS
Items Included in System:
Polar White Part #’s
301-041-00001
301-041-00002
301-041-00003
301-041-00004
Spin Weld - Spray Head
Part #201-009-00001
Atmospheric Vacuum In-Line Check Valve Label
Breaker/Check Valve
Part #501-006-00006 Part #103-002-00014
Part #501-009-00002
OR
ABS Tank - Spray Head
Part #501-006-00006
58471 Fir Road, Mishawaka, IN 46544
Phone: (574) 259-7838 Fax: (574) 259-7939
www.bandbmolders.com
INSTALLATION INSTRUCTIONS
Improper installation, operation or servicing this product will result in equipment damage &
personal injury. This product should be installed & serviced by qualified technical personnel
who have an in-depth knowledge of the construction process and potential hazards of this type
of system.
• All B&B installed fittings are torqued to factory settings. Loosening or tightening these connections will
result in potential leakage or damage voiding warranty consideration.
• All plumbing connections made to this product during installation should be hand tight plus ¼ turn.
DO NOT over-tighten!!
• DO NOT "operate" equipment at power levels other than what is specified on equipment serial tag & data
plate.
• Make sure tank fittings for black water tank flushing (ABS Tank & Rotomolded) are installed per
instructions to avoid potential damage.
• DO NOT install panel with plumbing in a binding condition. Plumbing must have necessary room to move
freely when panel is secured to mounting substrate.
• Double check ALL factory installed swivel fittings to hand tight plus ¼ turn due to potential loosening.
• OEM Manufacturer to provide user instructions clearly advising proper winterizing techniques. Damage to
system due to incorrect winterizing techniques voids all warranty consideration.
• B&B Molders is not responsible for damage caused to other products connected to this system. It is the
O.E.M. Manufacturer's responsibility to ensure plumbing is run to correct locations.
• Proper venting of freshwater holding tank is responsibility of RV manufacturer. (See B&B Power Vent for
safe venting options.) Under sized vents may result in serious damage.
• Special rules apply for any warranty claim or submission. Please contact B&B Molders for further
information.
• Do not use countersink headed screws due to potential cracking. Use only #8 pan headed screws.
• Nautilus System is designed for compartment use only and should not be used for exterior applications
where exposure to exterior elements exists.
• System must be installed in a clean environment at O.E.M. free of dust and debris. Foreign contaminates
have been proven to create leakage conditions.
• Optional: If this product comes equipped with a hot/cold faucet, make sure hot and cold are connected
correctly. All plumbing connections made to this product during installation should be hand tight plus ¼
turn.
Tank Flush
• DO NOT over-tighten swivel fitting to threaded water inlet connection. Over-tightening may result in stress
cracking to plastic threads.
• DO NOT plumb Atmospheric Vacuum Breaker/Check Valve (Vac/Check) in a binding condition that puts
stress on part. Plumbing should be securely fastened to permanent structure.
• B&B strongly recommends installing Vac/Check within 6' – 8' of water inlet due to low pressure conditions.
• Vac/Check must be installed in an easily accessible location to end user.
• Vac/Check assembly must be plumbed in proper direction of flow & orientation.
• Working pressure per ASSE #1001 is 125 psi but NOT LESS THAN 8 psi.
• Spin weld fitting/sprayer must be installed according to Standard Plastic Welding Guidelines.
IMPORTANT: FAILURE TO FOLLOW THESE INSTRUCTIONS FOR INSTALLATION OF OUR PRODUCT WILL
FORFEIT ANY WARRANTY CONSIDERATION.
58471 Fir Road, Mishawaka, IN 46544
Phone: (574) 259-7838 Fax: (574) 259-7939
www.bandbmolders.com
INSTALLATION INSTRUCTIONS
IMPORTANT!!
NEVER push check valve on "CITY WATER" connection
with pressure in line. This WILL cause irreparable damage
to the check valve function.
58471 Fir Road, Mishawaka, IN 46544
Phone: (574) 259-7838 Fax: (574) 259-7939
www.bandbmolders.com
INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS
Nautilus P3 Handle Position and
Valve Routing Information
WHITE HANDLE: Receives water from water inlet on front of panel
Sideways - water goes to pump inlet
Down – water goes into blue handled diverter
BLUE HANDLE: Receives water from the white handle valve/water inlet on front of panel
Sideways - water goes to fixtures (cold)
Down – water will go to or come from fresh water tank
GREEN HANDLE: Is an on/off flow through valve that feeds pump from fresh water tank
Sideways - water will not flow through valve
Up – water will go to or come from fresh water tank
RED HANDLE: Receives water from cold water supply line
Sideways - water goes to hot water fixtures without going through hot water heater
Up – water goes to hot water heater
58471 Fir Road, Mishawaka, IN 46544
Phone: (574) 259-7838 Fax: (574) 259-7939
www.bandbmolders.com
INSTALLATION INSTRUCTIONS
CONDENSED INSTRUCTIONS FOR QUICK REFERENCE
1. Cut a 13½ x 8½ opening in substrate material and feed
necessary connections through opening..
2. Connect (PUMP INLET) harness to back of Nautilus Panel.
3. Connect (FRESH TANK) harness to back of Nautilus Panel.
4. Connect (PRESSURE TO PUMP) harness to back of Nautilus
Panel
5. Connect (WATER INLET) harness to back of Nautilus Panel.
a. WITH FILTER: Connect (WATER INLET) at bottom of panel to
(FILTER IN) and connect (FILTER OUT) to (WATER INLET)
at top of panel.
b. WITHOUT FILTER: Connect (WATER INLET) at bottom of
panel to (WATER INLET) at top of panel.
6. Connect (HOT H2O LINE) harness to back of Nautilus Panel.
7. Connect (H2O HEATER) harness to back of Nautilus Panel
8. Connect (COLD H2O LINE) harness to back of Nautilus Panel.
9. Connect plumbing line running from (TANK FLUSH) to bottom of
listed (VAC/CHK).
10. Connect necessary coaxial cable(s) to appropriate connection
identified on top left panel and hand tighten.
11. Connect power service to terminals on back of pump switch,
located on top right panel. Mare sure wiring connection is routed correctly
for two switch operation.
12. Secure panel to substrate material using (8) #8 self-tapping, pan-head
operation.
**Connections shall be hand tight + ¼ turn. Do NOT over tighten as
stress cracking may result
58471 Fir Road, Mishawaka, IN 46544
Phone: (574) 259-7838 Fax: (574) 259-7939
www.bandbmolders.com
INSTALLATION INSTRUCTIONS
FULL HARNESS ASSEMBLY
HARNESS INFORMATION:
: Pump Inlet
: To Fresh Tank
: Pressure from Pump
: Water Inlet
: Hot H2O Line
: To H2O Heater
: Cold H2O Line
: Tank Flush
58471 Fir Road, Mishawaka, IN 46544
Phone: (574) 259-7838 Fax: (574) 259-7939
www.bandbmolders.com
INSTALLATION INSTRUCTIONS
PUMP INLET (PLUMBING HARNESS)
Items Needed:
• (2) 90° Swivel Fittings
• (1) Inline Tee
• (4) Oetiker Clamps
• 1/2” Pex Tubing Lines:
(2) 2 ⅜"
To connect pump inlet
harness, screw swivel
fittings onto diverter valves
- (TO PUMP INLET) as
illustrated. This line will
run directly to “IN” side of
water pump.
Connections shall be hand tight + ¼ turn.
Do NOT over tighten as stress cracking may result.
58471 Fir Road, Mishawaka, IN 46544
Phone: (574) 259-7838 Fax: (574) 259-7939
www.bandbmolders.com
INSTALLATION INSTRUCTIONS
TO FRESH TANK (PLUMBING HARNESS)
Items Needed:
• (2) 90° Swivel Fittings
• (1) Inline Tee
• (4) Oetiker Clamps
• ½” Pex Tubing Lines:
(2) 2 1/16”
To connect fresh tank
plumbing harness, screw
swivel fittings onto diverter
valves (TANK FILL
CITY & FROM TANK) as
illustrated. This line will run
directly to bottom of fresh
water tank.
Connections shall be hand tight + ¼ turn.
Do NOT over tighten as stress cracking may result.
58471 Fir Road, Mishawaka, IN 46544
Phone: (574) 259-7838 Fax: (574) 259-7939
www.bandbmolders.com
INSTALLATION INSTRUCTIONS
PRESSURE FROM PUMP
Items Needed:
(1) Straight Swivel Fittings
To connect plumbing line
coming from pump, screw
swivel fitting onto diverter valve
- (PRESSURE FROM PUMP)
as illustrated. This line will run
directly to “OUT” side of water
pump.
Connections shall be hand tight + ¼ turn.
Do NOT over tighten as stress cracking may result.
58471 Fir Road, Mishawaka, IN 46544
Phone: (574) 259-7838 Fax: (574) 259-7939
www.bandbmolders.com
INSTALLATION INSTRUCTIONS
WATER INLET WITHOUT FILTER (PLUMBING HARNESS)
Items Needed:
• (2) 90° Inline Elbows
• (2) Straight Swivel Fittings
• (6) Oetiker Clamps
• 1/2” Pex Tubing Lines:
(1) 1⅝”, (1) 3”, (1) 5⅜”
UNITS WITHOUT FILTER
To connect water inlet harness,
screw swivel fittings onto diverter
valves (WATER INLET) as
illustrated.
UNITS WITH FILTER
To connect line running to
(FILTER IN), screw swivel fitting
onto (WATER INLET) at
bottom of panel. To connect line
running to "FILTER OUT," screw
swivel fitting onto (WATER
INLET) at top of panel.
Connections shall be hand tight + ¼ turn.
Do NOT over tighten as stress cracking may result.
58471 Fir Road, Mishawaka, IN 46544
Phone: (574) 259-7838 Fax: (574) 259-7939
www.bandbmolders.com
INSTALLATION INSTRUCTIONS
HOT H2O LINE (PLUMBING HARNESS)
Items Needed:
• (1) 90° Inline Elbows
• (1) Inline Tee
• (2) Straight Swivel Fittings
• (6) Oetiker Clamps
• 1/2” Pex Tubing Lines:
(2) 1½”, (1) 2”
To connect hot water line
plumbing harness, screw
swivel fittings onto diverter
valves (HOT & HOT H20
LINE). This line will
connect to the hot water
line feeding fixtures.
• HOT on Shower Faucet
• HOT H2O LINE
Connections shall be hand tight + ¼ turn.
Do NOT over tighten as stress cracking may result.
58471 Fir Road, Mishawaka, IN 46544
Phone: (574) 259-7838 Fax: (574) 259-7939
www.bandbmolders.com
INSTALLATION INSTRUCTIONS
TO H2O HEATER
Items Needed:
• (1) 90° Swivel Fitting
To connect plumbing line
running to hot water heater,
screw swivel fitting onto
diverter valve (TO H20
HEATER) as illustrated.
This line will run directly to
“IN” on hot water heater.
Connections shall be hand tight + ¼ turn.
Do NOT over tighten as stress cracking may result.
58471 Fir Road, Mishawaka, IN 46544
Phone: (574) 259-7838 Fax: (574) 259-7939
www.bandbmolders.com
INSTALLATION INSTRUCTIONS
COLD H2O LINE (PLUMBING HARNESS)
Items Needed:
• (2) 90° Inline Elbows
• (2) Inline Tees
• (2) Straight Swivel Fitting
• (1) 90° Swivel Fitting
• (12) Oetiker Clamps
• ½ Pex Tubing Lines
(1) 4", (1) 3½", (1) 2⅞, (1) 1¾"
(1)1⅝", (1) l½"
To connect the cold line
plumbing harness, screw
swivel fittings onto diverter
valves (COLD, COLD LINE
SUPPLY, & CITY TO
FIXTURES) as illustrated.
This line will connect to the
cold water line feeding
fixtures.
Connections shall be hand tight + ¼ turn.
Do NOT over tighten as stress cracking may result.
58471 Fir Road, Mishawaka, IN 46544
Phone: (574) 259-7838 Fax: (574) 259-7939
www.bandbmolders.com