0% found this document useful (0 votes)
399 views43 pages

Selec Catalogue

This document appears to be a product catalog from a company called selec that produces automation equipment including programmable logic controllers, temperature controllers, meters, timers, and other industrial devices. The catalog provides specifications and details on their new and existing product lines. It includes sections on PLCs, accessories, protection relays, meters, timers, and other devices. Product pages provide information on models, features, specifications, and ordering details.

Uploaded by

Sumit Dey
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
399 views43 pages

Selec Catalogue

This document appears to be a product catalog from a company called selec that produces automation equipment including programmable logic controllers, temperature controllers, meters, timers, and other industrial devices. The catalog provides specifications and details on their new and existing product lines. It includes sections on PLCs, accessories, protection relays, meters, timers, and other devices. Product pages provide information on models, features, specifications, and ordering details.

Uploaded by

Sumit Dey
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 43

selec

Creating Best Value


PRODUCT
CATALOG

4Temperature Controllers 4Process Indicators 4Protection Relays


4Counters 4Meters 4Timers 4PLCs

www.selec.com | sales@selec.com
Our factory
at Mahape,
Navi Mumbai

Automated
manufacturing
Fully automated,
latest technology
Electronic
manufacturing plant

Automated Testing
Automated testing &
calibration for
error free results

Mechanical
Engineering
In house design,
tooling & plastics
Distribution
Wide distribution in
India & around the World

Technology
Time tested technology
matured through
continuous improvement
& innovation

Certification
ISO 9001:2008
CE, UL
marking for
select products

Quality
Value selec
www.selec.com
Creating Best Value
NEW PRODUCTS

Multifunction Meter Energy Meter Digital Panel Meter


Pg 08 Pg 09 Pg 06

Digital Timers
Pg 21

Analog Timers
Pg 25

New TC Series
Pg 14
selec
Contents
Programmable Logic Controllers 01

Accessories 04

Protection Relays 05
Digital Panel Meters 06

Electrical Panel Meters (Contd... ) 07

Electrical Panel Meters 08


Energy Meters 09

Hotrunner Controllers 10

Advanced PID Temperature Controllers 11

Economical PID Temperature Controller 13

Economical PID Temperature Controller (New Series) 14

Process Indicator 16

Low Cost Digital Temperature Controllers 17


Digital Timers 19

Digital Timers (New Series) 21

Timers - 800 Series 22

Timers - 642 Series 24

Din Rail Timers - 600 Series (New Series) 25


Plug / Panel Mount Timers - 55 Series 26

Digital Counters 27

Rate Indicators / Switch 29


Totalisers & Time Measuring Instruments 30

Appendix
Accessories 31
Timing Diagrams 32
Dimensions 36
Programmable Logic Controllers
Single Box Solution
selec
! Upto 47 I/Os
Built in: ! Upto 6 analog channels
!HMI
!I/Os
! Upto 8 Digital inputs
!Relays ! Upto 5 Relays / Digital outputs
!Analog (including temp. ! One analog input

sensor inputs)
!24V to drive inputs
48 x 96
96 x 96
MM3010 MM1010 MM1012 MM1013
DISPLAY LCD (backlight) 4 line x 16 character 7 segment LED, 3 digit + (4 + 4) digit

No. of Keys 18 (10 numeric keys) 5

No. of Configurable Keys 14 4

DIGITAL SECTION

DIGITAL INPUT (Refer card selection table for available options)


Dependent on card selections
No. of Digital Inputs 8 6 8
(refer table 1.0 on Page 02)

Input Type PNP PNP

Input Voltage Range 11 - 28V DC (abs. max.: 30V DC) 11 - 28V DC (abs. max.: 30V DC)

Response Time (Inputs other than fast counter) Programmable upto I - 255ms from front end Programmable upto I - 255ms from front end
(default 10ms) (default 10ms)
Isolation 2 kV 2 kV

Fast Counter Input


Bidirectional, Unidirectional: 7.5 kHz
Operating Modes / Frequency
Quadrature: 2.5 kHz
Maximum Count 10 digits

DIGITAL OUTPUT - Relay (Refer card selection table for available options)
Dependent on card selections
No. of Relays (refer table 1.0 on Page 02) 5 4 5
4ch / 8ch: 5 A resistive @ 240V AC 5 A resistive@240V AC
Relay (NO Type) Contact rating
11ch: 3 A resistive @ 240V AC 3A resistive @240V AC (for MM1010-24V only)
Minimum Switching Time 10 msec 10 msec 20 msec 20 msec

Isolation 2kV 2kV

DIGITAL OUTPUT - Transistor (Refer card selection table for available options)

No. of Transistor output Dependent on card selections


(refer table 1.0 on Page 02)
For 14 Channels:
Transistorised Output rating
PNP Type: 24V, 100mA
Short Circuit Protection Yes

Max. Switching Frequency 1kHz

ANALOG SECTION

ANALOG INPUT (Refer card selection table for available options)

Dependent on card selections 1 2


No of Inputs / Type
(refer table 1.0)
TC / RTD / 0-20mA / 0-10V TC / RTD / 0-10V / 0-20mA (User selectable)

Conversion Time 100msec 100msec

Resolution 16 bit 16 bit

ANALOG OUTPUT (Refer card selection table for available options)


No. of Analog Outputs 2 1

Output Type 0-20mA / 0 - 10V (factory set) 0-20mA / 0 - 10V


(factory set)
Resolution 14 bit 14 bit

Conversion Time 20 msec 20 msec

Linearity Error 0.1% 0.1%

1
MM3010 MM1010
selec
MM1012 MM1013

FUNCTIONAL SPECIFICATIONS
Programming Method Windows based software for ladder program Windows based software for ladder program
& HMI configuration & HMI configuration
Memory Data memory: 16K Data memory: 16K
Code memory: 351K, Upload memory: 96K Code memory: 223K
No of Objects Maximum 5000 (as per memory) Maximum 5000 (as per memory)

Minimum Scan Time 200 µsec 200 µsec

FUNCTION BLOCKS
Universal Timer: ON delay, OFF delay, Pulse, Up timer, ON delay, OFF delay, Pulse timer, Up timer, Down
Timer Down timer (10 ms) , 1 ms timer timer, Universal Timer (10 ms), 1 ms timer
Up counter, Down counter, Up/down counter Up counter, Down counter, Up / down counter (10 digit)
Counter
(Upto 10 digits)
PID Control (Autotuning), Analog input, Analog output, PID Control (Autotuning), Analog input,
Other Blocks
Time switch, Communication (Master) Analog Output
Master - RS485; 1 RS485 port (slave) (Isolated)
Communication Ports
Slave -RS232 / RS485 (selectable via Jumper)
Communication Protocol MODBUS RTU MODBUS RTU

Memory Retention 10 years 10 years

RTC Yes No

Supply Voltage 90 - 270V AC/DC, 24V DC, AC@50/60 Hz 90 - 270V AC/DC, 24V DC, AC@50/60 Hz
Operating: 0 to 50oC Operating: 0 to 50oC
Temperature
Storage: -20 to 60oC Storage: -20 to 60oC
Humidity (non-condensing) 95% RH 95% RH

Weight 564 gms 258 gms

Certifications (For MM1010 only)

Dimensions Refer diagram D on page 36 Refer diagram H(V) on page 36

Ordering Code Please see overleaf for ordering information Please see overleaf for ordering information

Table 1.0
There are 4 card slots internal to the unit. I/O combinations available Order Codes
These cards are factory fitted but possible to
select while ordering. Each card slot has some Slot 1 8 Digital Input DI08
Digital Input Cards
selectable card types that can be inserted. 13 Digital Input DI13
Detailed information regarding these cards is
provided in adjacent table. 19 Digital Input + 1 Quad DIQ19

Slot 2 8 Digital Output (Relay Type) DR08


Digital output Cards
11 Digital Output (Relay Type) DR11

14 Transistor Output, PNP, 100mA DT14


Slot 1 Digital Mixed I/O: 8DI + 4DO
Slot 3 MDI08R04
Digital / Analog Mixed I/O Cards
Slot 2 6 Channel Analog I/P: AI 06 (Thermocouple/RTD type) AI06-T/R

6 Channel Analog I/P: AI 06 (Voltage/current type) AI06-V/I


Slot 3
2 Channel Analog I/P: AI 02 (universal input) AI02
Analog Mixed I/O: 4AI + 2AO
4AI (Universal I/P) Set internal Jumpers (Default TC/RTD) MAI04O02
Slot 4 2AO (factory set) To be specified while ordering (0-10V/0-20mA)

Slot 4 90 to 270V AC/DC 270 V


Power Supply
24V DC 24V DC

2
Ordering Information (MM3010)
MM3010
selec
C1 C2 C3 C4

Choose from Legend


Legend

Digital Input Card Digital Output Card Digital/Analog Mixed Input Card Power Supply

C1 Configuration C2 Configuration C3 Configuration C4 Configuration

DR08 MDI08R04 8 Digital Inputs +


DI08 8 Digital Inputs Relay type
8 Digital Outputs Only relay type 270 V 90 to 270V AC/DC
O/P available 4 Relay Outputs

DR11 6 Analog Inputs


DI13 13 Digital Inputs 11 Digital Outputs AI06- T/R 24V DC 24V DC
Relay type TC / RTD type

DT14 14 Transistor Outputs, 6 Analog Inputs


DIQI9 19 Digital Inputs + 1 Quad AI06- V/I
Transistor type (100mA each) Voltage / Current type

2 Analog Inputs
AI02
Universal type

! NOTE
4 Analog Inputs +
*MAI04O02
* In case of MAI04O02, type of Analog Input/Output to be 2 Analog Outputs
specified separately.
INPUTS OUTPUTS
TC 0-10V
RTD
Voltage
0-20mA Ordering Example
Current MM3010 - DI13 - DR11 - AI02 - 270V
MM3010 - Digital Inputs: 13 - Digital Outputs: 11 -
Analog Inputs : 2 - Supply Voltage : 90 to 270V AC/DC

Ordering Information (MM1010, MM1012 & MM1013)


Order Code Supply Voltage ! NOTE
MM1010-T/R-24V DC 24V DC In case of MM1012 type of Analog Input/Output to be
specified separately.
MM1010- T/R-230V 90 to 270V AC/DC INPUTS OUTPUTS
MM1010-V-230V 90 to 270V AC/DC TC 0-10V (for MM1012-1)
RTD 0-20mA (for MM1012-2)
MM1010-V-24V DC 24V DC Voltage
Current
MM1010-I-230V 90 to 270V AC/DC

MM1010-I-24V DC 24V DC
MM1012-230V 90 to 270V AC/DC
MM1012-24V DC 24V DC

MM1012-1-230V 90 to 270V AC/DC


MM1012-1-24V DC 24V DC

MM1012-2-230V 90 to 270V AC/DC


MM1012-2-24V DC 24V DC

MM1013-230V 90 to 270V AC/DC


MM1013-24V DC 24V DC

Accessories Communication cable


Part no. - ACH-001. (9 pin D-type cable)
(to be ordered separately)
Windows-based software for ladder programming
Part no. - ACD-003

Four Relay module


Part no. - AR - 04 - 5A - NONC (SPDT)
AR - 04 - 5A - NO (SPST)

Power Supply module


Part no. 1) AP-24V-500mA-NS131

RS485 to RS232 converter


Part no. - AC - RS485 - RS232 - 01 (non isolated)
AC - RS485 - RS232 - ISO (with isolation)

3
Accessories selec

24V DC Power Supply RS232-485 Converter 4 Relay Module

Supply Voltage 90-270V AC/DC@ 50-60Hz 90-270V AC/DC@ 50-60Hz 24V DC, 40 mA for 4 relays,
Max. input current 50 mA Max. input current 50 mA each relay ON at 24V DC, 10 mA
4 relay outputs with NONC
Contact rating: 5 A resistive/
Output 24V DC, maximum current 500 mA 1 A inductive
minimum switching time: 10 ms

Transmission Speed 9600 to 115200 BPS

Transmission Mode 2-wire (half duplex)

Isolation 2 kV 2 kV 2 kV

Temperature Operating: 0 to 50°C Operating: 0 to 50°C Operating: 0 to 50°C


Storage: -20 to 75°C Storage: -20 to 75°C Storage: -20 to 75°C
Humidity (non-condensing) upto 95% upto 95% upto 95%

Weight 110 gms 80 gms 130 gms

Dimensions Refer diagram P(I) on page 37 Refer diagram S on page 37 Refer diagram P(I) on page 37

Ordering Information
Product Name Order Code Product Name Order Code

24VDC Power Supply AP-24V-500 mA RS232-RS485 Converter AC-RS485-RS232-01


(without isolation)
RS232-RS485 Converter (with isolation) AC-RS485-RS232-ISO 4 Relay Module AR-4-5A-NO/NC

FI400 CBCTs for Earth Leakage Relay

Description Frequency to current converter Description CBCT

Inputs a) Voltage pulse: 3 to 30 VDC or CT Ratio 1200:1


(factory set) 3 wire DC proximity switch
b) 2 wire Namur proximity switch Sizes
(inner diameter) 35mm, 70mm, 120mm
Max. Frequency 999, 99.9, 9.99, 0.999 Hz

Accuracy ± 0.5%
Ordering Information
Sensor Supply 12V DC, 30 mA Inner Diameter Order Code
(in mm)
Damping Factor 512, 256, 128, 64, 32, 16, 8 or 4 (selectable by push wheel)
35 CBCT-35
Check Mode To verify minimum & maximum output values
70 CBCT-70
a) 0-20mA / 4-20mA
Output
b) Pulse repeat output (open collector) 120 CBCT-120
Supply Voltage 230 / 110V AC (user selectable), 50/60Hz

Temperature Operating: 0 to 50°C


Storage: -5 to 50°C
Humidity
upto 95%
(non-condensing)

Weight 420 gms

FI400 - Proximity: 3 wire DC proximity input


Ordering Code
FI400 - Ag 19: 2 wire namur proximity input

4
Protection Relays selec

ELR 600 VPR 604 CPR 605 FPR 602

Description Earth Leakage relay Voltage Protection relay Current Protection relay Frequency Protection relay
3 Ø-4 wire & 1 Ø 3 Ø-4 wire 3 Ø-4 wire 1Ø
1. Trip Relay: Fail Safe Relay: 1. Normal Relay: 1. Trip Relay:
1 SPDT: NO (5 A@250V AC) 1 SPDT: relay with 7A @ 250 / 30 1 SPDT: NO (5A@250V AC) 1 SPDT: 5A@250V AC/24V DC
Output Contact NC (3 A@250V AC ) NC (3A@250V AC) 2. Fail Safe Relay:
2. Fail Safe Relay: 2. Fail Safe Relay:
1 SPST: NO (5A @ 250V AC) 1 SPST: 5A @ 250V AC/24V DC
1 SPST: NO ( 10 A @ 250V AC)
Power
Consumption 3VA 5VA 11VA 10.5VA
Nominal
Values 240V AC 5A 50Hz

TRIP SETTING
Leakage via CBCT(see accessories on pg 4 )
Current 30,100,300,500 mA, 1,3,5,10,20,30 A
Under 180V AC to 234V AC (Vn -% (25,
Voltage 22.5, 20,17.5,15,12.5,10,7.5,5,2.5))
Over 246V AC to 300V AC (Vn +% (2.5,5,
Voltage 7.5,10,12.5,15,17.5,20,22.5,25))
Over 30,40,50,60,70,80,90,100,110,
Current 120 % of phase current
Under
40,41,42,43,44,45,46,47,48,49 Hz
Frequency
Over
51,52,53,54,55,56,57,58,59,60 Hz
Frequency
Power ON, Trip, % of leakage / Normal operation,Under/Over voltage Power ON, Tripped condition Normal operation(frequency within
LED Indication
CBCT error condition, Phase reverse condition trip setting), Under & Over frequency
Hysteresis Approx. 2% of trip levels (factory set) 5, 10, 15, 20, 25, 30% of trip current -0.5 to 2Hz (dependent on under &
over frequency trip settings)
Power ON Delay Approx. 400 ms Approx. 100 ms Approx. 100 ms

Trip Time Delay 0 to 9 seconds (adjustable) 0.2 to 10 seconds (adjustable) 0.2 to 10 seconds (adjustable) 0 to 9 seconds (adjustable)

Accuracy ± 5% of F.S. (30,100,300,500 mA,1,3,5A) ± 0.5% at constant condition ± 0.5% at constant condition ± 0.5% at constant condition
± 12% of F.S. (10,20,30 A)
Below 85% of tripped level & in the
presence of CBCT by:
Auto reset on removal of Auto reset on removal of Auto reset on removal of
Reset 1)Front reset fault condition fault condition fault condition
2)Remote reset
3)On power interruption
Rated Current 5A

CBCT Ratio 1200 : 1 (Please see page 4 for


compatible CBCT selection)
Phase Current 5 A, AC (50-60 Hz)
Supply Voltage 230V AC (± 15%) 240V AC (± 30%) 240V AC (± 25%) 240V AC (± 30%)
AC: 50 or 60 Hz

Temperature Storage / Operating: 0 to 50°C Storage / Operating: 0 to 50°C Storage / Operating: 0 to 50°C Storage / Operating: 0 to 50°C
Humidity
(non-condensing) 95% RH 95% RH 95% RH 95% RH

Weight 190 gms 180 gms 130 gms 100 gms

Dimensions Refer diagram P(I) on page 37 Refer diagram P(I|) on page 37 Refer diagram P(I|) on page 37 Refer diagram P(I|) on page 37

Terminal Fail Safe Relay Trip relay Fail Safe Relay L1+ L1- L2+ L2- L3+ L3-
Connections 18 17 16 15 14 13 12 11 10 18 17 16 15 14 13 12 11 10 18 17 16 15 14 13 12 11 10 18 17 16 15 14 13 12 11 10
COM NO NC COM NO NO COM NC COM NO NC COM NO

RLY1 NO NC NO RLY1
RLY2
RLY1 COM RLY2 COM

1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9
CBCT COM N L NORMAL FAIL SAFE N L
N L1 L2 L3
(R) (Y) (B) SUPPLY RELAY RELAY
L1
L2 TST
L3 SUPPLY
N 3Ø Input

Ordering Code ELR600 VPR604 CPR605 FPR602

5
Digital Panel Meters selec
NEW
NEW

72 x 72 96 x 96 48 x 96 96 x 96
48 x 96 72 x 72
MA12-DC-75mV MA12-AC-20A
MA12 ; MA202; MA302 MA302-DC-75mV MA302-AC-20A MV15 ; MV205; MV305
Description Digital Ammeter Digital Voltmeter
Display 4 digit, 7 segment LED Display 3 digit, 7 segment LED display

Display Range 0 to 4960A (scaled as per CT) 24.8A 0 to 516V

Input Range 50mA to 5A AC 75mV at Primary current 20A (Direct type) 50 V to 480V AC
(external 75mV, 5A DC rated shunt)

Method True RMS True RMS

Accuracy ± 0.5% of F.S. ± 0.5% of F.S. over rated


±0.5% of 20A operating conditions
Measuring Element Drop 0.07V at 5A 0.23W at 480V AC input

Input Impedance 1M Ώ (± 5%)

CT Primary 5, 10, 20, 30, 40, 50, 60, 75, 80, 100,150, 200, 250, 300, 400, 500, 600,
800,1000, 1200,1500,1600, 2000, 2500, 3000, 4000
Continuous Max. Input Rating 6.2A AC 6.2A AC 24.8A AC 516V AC

Sampling Rate 3 samples / second 3 samples / second

Supply Voltage 240 VAC, ±20%, 50/60 Hz; 110VAC, ±20%, 50/60 Hz 240V AC, ± 20%, 50/60Hz;
110VAC, ±20%, 50/60 Hz
Power Consumption 3VA maximum 3VA maximum

Temperature 0 to 50°C 0 to 50°C

Humidity (non-condensing) 85% RH 85% RH

MA12: 170gm, MA202: 180gm, MA302: 180gm MV15: 170gm,MV205: 180gm,


Weight
MV305: 180gm

48 x 96 96 x 96 48 x 96 96 x 96
MF16 ; MF316 MP14 ; MP314
Description Digital Frequency Meter Digital Power Factor Meter

Display 4 digit, 7 segment LED Display 4 digit, 7 segment LED Display


Over Range / "Ovfr" (Over 99.99 Hz)
Under Range Indication "Ur" (Under 40.00 Hz)
Resolution 0.01 0.001

Input Voltage Range Self Powered Self Powered


Input Measurement Range / 40.00 - 99.99 Hz 0.25 - 6A (AC)
Current Input Measurement
Accuracy ± 0.05 Hz ± 0.5% ± 1 digit
Auxiliary Supply Voltage (Vn), 240 / 110VAC (± 20%), 45 - 65 Hz 240 / 110VAC (± 20%), 50-60 Hz
Frequency Range
Supply Variation 0.75 to 1.25 x Vn 0.75 to 1.25 x Vn

Over Voltage 1.5 x Vn continuous, 2 x Vn (3s) 1.5 x Vn continuous, 2 x Vn (3s)

Electrical Connection 1Ø 1Ø 2 wire

Temperature Operating: -20°C to 60°C ; Storage: -30°C to 80°C Operating: -20°C to 60°C ; Storage: -30°C to 80°C

Ordering Code MF16 ; MF316 MP14 ; MP314

DIMENSIONS: MA12,MV15,MF16,MP14 Refer diagram H(U) on page 36 ; MA302,MV305,MF316,MP314: Refer diagram Q(II) on page 37;
MA202, MV205: Refer diagram W on page 37

6
Electrical Panel Meters selec

96 x 96 96 x 96 96 x 96 96 x 96
Applicable only for MFM383C Applicable only for VAF36
! 3 Ø (rms) Voltage ! Monitors average value of Voltage,
! 3 Ø (rms) Current ! 3 Ø (rms) Voltage ! Monitors average value of Voltage, Current & Frequency
! 3 Ø power (Active, Reactive, ! 3 Ø (rms) Current Current & Frequency ! Programmable CT Primary
Apparent) ! 3 Ø Power (Active, Apparent) ! Programmable CT Primary
! 3 Ø Power factor ! 3 Ø Power factor
! Frequency ! Frequency
! Programmable CT Primary ! Energy
! Programmable CT Primary
! RS485 Communication (MFM383C)
MFM309 MFM383 / MFM383C VAF32 & 36 VAF39
Description Multifunction Meter Multifunction Meter V.A.F. Meter V.A.F. Meter
VAF32: Liquid crystal display 7 segment LED; Height: 0.5”
Display 7 segment LED; Height: 0.5” Liquid crystal display (with backlight)
VAF36: Liquid crystal display (backlight)

3 rows of 3 digits 3 rows of 3 digits, Bar graph, 3 rows of 3 digits, Bar graph 3 rows of 3 digits
Digits
8 digits for energy
Input Type 3 Ø-4 wire & 1 Ø - 2 wire 3 Ø-4 wire & 1 Ø - 2 wire 3 Ø-4 wire & 1 Ø - 2 wire 3 Ø-4 wire & 1 Ø - 2 wire
Rated Input 5A max. 5A max. 5A max. 5A max.
Current
Display
Auto / Manual Auto / Manual Auto / Manual Auto / Manual
Scrolling
Range 99999999 for energy
0.01, 0.1, 1 0.01, 0.1, 1, Auto shift from 0.1 to 1 0.01, 0.1, 1 0.01, 0.1, 1
Resolution* (depending on CT Primary) for energy (depending on CT Primary) (depending on CT Primary) (depending on CT Primary)
1) 50Hz 1) 50Hz 1) 50Hz 1) 50Hz
Frequency
2) 60Hz 2) 60Hz 2) 60Hz 2) 60Hz
CT Primary 5 to 5000 programmable 5 to 5000 programmable 5 to 5000 programmable 5 to 5000 programmable

Burden (max) 0.2VA max per phase 0.2VA max per phase 0.2VA max per phase 0.2VA max per phase

Accuracy As per table 1 As per table 1 As per table 2 As per table 2

Display Reset Programmable (for energy)

Memory 10 years (for energy)


LED/Parameter
LED/Parameter 1) LCD for all measured parameters 1) LCD for all measured parameters
LEDs for all measured parameters LEDs for all measured parameters
Indication
Indication 2) % of current in bar graph form 2) % of current in bar graph form
Communication RS485 (MODBUS) (MFM383C only)

Supply Voltage 90 to 270V AC/DC 90 to 270V AC/DC


Rated input VAF32: 170 to 270V AC
Voltage (L-N) 350V AC 350V AC 90 to 270V AC
VAF36: 90 to 270V AC
Operating: 0 to 50°C Operating: 0 to 50°C Operating: 0 to 50°C Operating: 0 to 50°C
Temperature
Storage: -20 to 75°C Storage: -20 to 75°C Storage: -20 to 75°C Storage: -20 to 75°C
Humidity 85% 85% 85% 85%
(non-condensing)
VAF32 - 180 gms
Weight 238 gms 250 gms 210 gms
VAF36 - 220 gms
Dimensions Refer diagram Q(II) on page 37 Refer diagram Q(II) on page 37 Refer diagram Q(II) on page 37 Refer diagram Q(II) on page 37
CT-R CT-Y CT-B
Terminal S1 S2 S1 S2 S1 S2 CT-R
S1 S2
CT-Y
S1 S2
CT-B
S1 S2
Connections
N N
R R
Y Y
B B

L N

N R Y B
N R Y B

MFM383 VAF32
Ordering Code MFM309 MFM383-C (Communication) VAF39
VAF36
Measurement Accuracy (%) Measurement Accuracy (%) Parameters Accuracy Measurement Accuracy
Voltage VL-N ±0.5% of F.S. +1 digit Frequency ± 0.1% of F.S. ± 0.1Hz Voltage VL-N ±0.5% of F.S.* Average Current Iavg ±1% of F.S.**
TABLE 2

Voltage VL-L ±1% of F.S. +1 digit Active Power ±1% of F.S. +1 digit Voltage VL-L ±0.5% of F.S.* Frequency ±0.1 Hz
TABLE 1

Average VoltageL-N ±0.5% of F.S. +1 digit Apparent Power ±1% of F.S. +1 digit * + ± 2 digit
Average Voltage VL-N ±0.5% of F.S.*
** + ± 2 digit@50 Hz
Average VoltageL-L ±1% of F.S. +1 digit Reactive Power ±1% of F.S. ± 2 digits *** + ± 2 digit@60 Hz
Average Voltage VL-L ±0.5% of F.S.*
Power Factor & *Resolution is dependent on the type of
Current ±1% of F.S. +1 digit ±0.01 PF +1 digit
Avg. Pf Phase current I ±1% of F.S.** parameter and the CT primary value.
For further details, refer instruction
Average current ±1% of F.S. +1 digit Energy Class 1 ±2% of F.S.*** manual.

7
Multifunction Meter
! 3 Ø (True rms) Voltage
selec
! 3 Ø (True rms) Current
! 3 Ø Power (Active, Reactive, Apparent)
! 3 Ø Power Factor
! Frequency
! Energy (Active, Reactive, Apparent)
! Programmable CT/PT primary/secondary Programmable (for energy)
Display Reset
NEW ! Modbus RTU Communication (RS485) (Optional)
! Pulse Output Memory Retention 10 years (for energy)
96 x 96 1) LCD for all measured parameters
MFM384 LCD/Parameter Indication 2) % of current in bar graph form
Description Multifunction Meter
Supply Voltage 85 to 270V AC
Display Liquid crystal display with backlight 19 to 519V AC (phase to phase), 50/60Hz
Rated input Voltage (L-N)
4 rows of 4 digits, lowest 8 digits for energy display 11 to 300V AC (phase to neutral), 50/60Hz
Digits
Bargraph representation for current
Pulse Output: Voltage range - 24V DC
Input Type 3 Ø - 3/4 wire, 2 Ø - 3 wire, 1 Ø - 2 wire OUTPUT Current capacity - 100 mA max
Pulse Width: 100 ms ± 50 ms.
Rated Input Current 10mA - 5A (6A max)
(External CT must be connected for current more than 5A) COMMUNICATION RS485 MODBUS Communication (Optional)
Display Scrolling Automatic / Manual Operating: 0 to 50°C
Temperature
Storage: -20 to 75°C
For energy- 0.01k, 0.1k, 1k, 0.01M, 0.1M, 1M, 10M
(depending upon CT ratio X PT ratio) Humidity (non-condensing) 85%
Resolution*
For Power, Voltage & Current- Auto resolution
For Power factor - Resolution is 0.001 Weight 395 gms

Frequency 50 or 60Hz Dimensions Refer diagram Q(III) on page 37


1A or 5A to 10,000A (Programmable for any value) N
CT Primary Terminal Connections L
Note : 1A or 5A depends upon the CT secondary

+
PULSE O/P RS485
CT Secondary Programmable between 1A or 5A
L1 L
PT Primary 100V to 500 kV L2 O
L3 A
N D
PT Secndarty 100 to 500V AC (phase to phase)
S1 S2 S1 S2 S1 S2 N V1 V2 V3
I1 I2 I3
Burden (max) 0.5VA max per phase @ 5A
Order code 1) MFM384
Accuracy As per table 1 Page No. 09
2) MFM384-C (Communication)

Automatic Power Factor Controller

96 x 96 96x96
APFC336 APFC338/310/312/314/316 Supply Voltage 90 to 270V AC/DC (AC: 50 or 60Hz )
Description Automatic Power Factor Controller Power Consumption 3 VA max @ 230 VAC
Display 7 segment LED ; Height 0.5”
Temperature Operating: 0 to 50°C ; Storage: -20 to 75°C
Digits 3 4 Humidity (non-condensing) 85%
Input Type 1 Ø - 2 wire Number of Stages* 6 APFC338 - 408 gms
APFC310 - 428 gms
Nominal Input Current 5A APFC312 - 446 gms
Weight 227 gms APFC314 - 471 gms
APFC316 - 507 gms.
PF Measurement Range 2 % to 120 % of rated current
Refer diagram Q(II) Refer diagram G(Y)
Dimensions on page 38
CT (Current) absent on page 37
CT reverse
Error Indications Terminal Connections
Under Compensation
Over Compensation APFC336 APFC 310/314/316
Hysteresis 0.01 of Target PF Programmable: NO1 NO2 NO3 NO4 C1 NO5 NO6 NO7 NO8 C2
0.005 to 0.050 NO1 NO2 C1 NO3 NO4 C2 NO5 NO6 C3
1 2 3 4 5 6 7 8 9 10

Capacitor Switch ON time 30 sec – Fixed Programmable:


1.0 to 300.0 sec R1 R2 R3 R4 R5 R6 R7 R8

Capacitor Switch OFF time Programmable: NO9 NO10 NO11 NO12 C3 NO13 NO14 NO15 NO16 C4
30 sec – Fixed
1.0 to 300.0 sec R1 R2 R1 R2 R1 R2 31 32 33 34 35 36 37 38 39 40

Operating mode Automatic/Manual R R9 R10 R11 R12 R13 R14 R15 R16
Y P2 P1
Relay Switching Logic First on First off B L Ph
N O
A N
D
Operating Frequency 45 – 65Hz
11 13 18 20
S1 S2 L N
S1 S2 L N
Display Update Rate 2 sec 1 sec *For 10/14/16 stage consult factory 230V AC

8
Energy Meter NEW selec
! 3Ø Power (Active, Reactive)
! 3Ø Power Factor
! Energy (Active, Reactive, Apparent)
! Programmable C.T, P.T
! Modbus RTU Communication (RS485)
! Pulse Output

96 x 96 96 x 96
Applicable only for EM306

EM306/EM306C EM368/EM368C
Description Energy Meter Energy Meter

Display 7 segment LED ; Height 1.27mm LCD display. Height 10.5mm

Digits 6 8

Input Type 3 Ø - 4 wire & 1 Ø - 2 wire 3 Ø - 3/4 wire, 2 Ø - 3 wire, 1 Ø - 2 wire

Rated Input Current 6 A max. 10mA - 5A (6A max)


(External CT must be connected for current more than 5A)
For energy- 0.01k, 0.1k, 1k, 0.01M, 0.1M, 1M, 10M
0.01, 0.1, 1 & 10 (depending on CT primary) (depending upon CT ratio X PT ratio)
Resolution
For Power - Auto resolution
For Power factor - Resolution is 0.001
Frequency 50 Hz 50 or 60 Hz

5, 30, 40, 50, 60, 75, 80, 100, 150, 200, 250,300, 400,500, 1A or 5A to 10,000A (Programmable for any value)
CT Primary/ Secondary 600, 800, 1000, 1200, 1500,1600, 2000, 2500, 3000, 4000, 5000 Note : 1A or 5A depends upon the CT secondary

PT Primary/ Secondary 100V to 500kV / 100 to 500V AC


Burden 0.5 VA@5A per phase 0.5 VA@5A per phase

Class 1 for Active/Apparent energy


Accuracy Class 1 Class 2 for Reactive energy
Class 0.5 for Power
Integration of energy, Resolution is 10, Integration of energy, Resolution is 10,
LED Indications Reverse connected CT warning Reverse connected CT warning (All Indication on LCD)
Output Pulse Output: Voltage range - 24V DC Pulse Output: Voltage range - 24V DC
Current capacity - 100 mA max Current capacity - 100 mA max
Pulse Width: 500 ms ± 50 ms. Pulse Width: 100 ms ± 50 ms.
Supply Voltage 90 to 270V AC/DC 85 to 270V AC
Operating: 0 to 50 OC Operating: 0 to 50 OC
Temperature
Storage: -20 to 75 OC Storage: -20 to 75 OC
Humidity 85 % 85 %
(non-condensing)

Communication* RS485 communication (MODBUS protocol) RS485 communication (MODBUS protocol)

Weight 225 gms 310 gms

Dimensions Refer diagram Q(II) on page 37 Refer diagram Q(III) on page 37

Terminal Connections IR IY IB PULSE O/P KEY


S1 S2 S1 S2 S1 S2 - + N
L
+

N
R PULSE O/P RS485
Y
B

CONNECTIONS DIAGRAM
L1 L
L2 O
L3 A
N D

L N
S1 S2 S1 S2 S1 S2 N V1 V2 V3
I1 I2 I3
*For EM306-C/EM368-C consult factory N R Y B + -

1) EM306 1) EM368
Order code
2) EM306-C (Communication) 2) EM368-C (Communication)

TABLE 1
Accuracy : (MFM384) Frequency ±0.1% , For Voltage >20V L-N,
For Voltage >35V L-L
Measurement Accuracy
Active Power Class 1
Voltage VL-N ±0.5% of Full scale
Apparent power Class 1
Voltage VL-L ±0.5% of Full scale
Reactive Power Class 1
Average Voltage L-N ±0.5% of Full scale Power factor and Avg Power Factor ±0.01
Average Voltage L-L ±0.5% of Full scale Active energy Class 1
Current ±0.5% of Full scale Reactive energy Class 1
Average current ±0.5% of Full scale Apparent energy Class 1
*Resolution is dependent on the type of parameter and the CT primary value. For further details, refer instruction manual.

9
Hotrunner Controllers
! Solid state high speed thyristor control
selec
! Soft start
! Heater current indication
! Earth fault detection

TC75 (Single Zone, Two Zone, Four Zone, Six Zone, Eight Zone, Twelve Zone)
Description Hotrunner controllers for accurate mould temperatures

Display 7 segment LED display


3 digit dual display
Digits Upper Display: PV and parameter name
Lower Display: SV and parameter value (selectable)
LED Indications 8 LED indications on front panel

Inputs Thermocouple: J and K type


Range: 0 to 537°C (999°F)
Resolution 1° fixed
Control
±1°C (1°F) dependent on total thermal system
Accuracy
Temperature
°C or °F ( selectable)
Unit
Response 250 ms
Time
Auto and Manual Control functions
Control Action (Soft start system / Auto tune PID / ON-OFF Control modes)
Internal solid state thyristor control
Main Output
Power capability : 15A @ 230V AC
Overload
Protection 15A internal fuse
Adjustable from 0-100%, maintains output power
Manual Control
within 1% of setpoint
Soft Start Variable stepping voltage, 18 V to Line voltage

Heater current monitoring


Heater current alarm
Special Open triac or heater detection
Functions Ground fault detection
Boost mode
Standby mode

Supply Voltage 230 to 240V AC, -15% to 20% @ 50/60Hz


Power Supply
15A internal fuse
Protection
Operating: 0 to 50°C
Temperature Storage: -20 to 75°C
Humidity
(non-condensing) 85%

1 Zone: 2.8 kg
Weight 2 Zone: 4.6 kg
4 Zone: 9.5 kg
6 Zone: 11.9 kg
8 Zone: 15.6 kg
12 Zone: 20.5 kg

Dimensions Refer table R on page 37

Ordering Information Legend


TC75
A B C
A Choose from Legend
Length
Code Zones Code Connector Type Code
of cable
Accessories
1 Single Zone M Male 4 4 meters
Connectors
2 2 Zone F Female 5 5 meters
TCHTCN75 A
Thermocouple 4 4 Zone 10 10 meters
& Heater B Choose from Legend
Connector 6 6 Zone 15 15 meters

8 8 Zone 20 20 meters
Cables
TCHTCL75 A 12 12 Zone
Thermocouple NOTE: For other configurations,
& Heater Cable C Choose from Legend consult factory

10
PID Temperature Controllers
Full Featured PID Series
selec
PID500 / 110 / 330
Profile Controller
! Heat cool ! 10 programs, 16 steps each
! Ramp soak ! Alarm at each step
! Soft start ! Memory during power fail
! Heater current monitoring
! Remote setpoint
! Motorised valve control
! RS485 communication

PID500 PID110 PID330 PR502


48 x 48 96 x 48 96 x 96 48 x 48
Common specifications for PID500 / 110 / 330 & PR502

Description Advanced PID controller, Cycle Time 0.1 to 100 sec


covers most applications
Upper: 7 segment red LED Manual Reset Value -99.9 to 99.9°
DISPLAY
Lower: 7 segment green LED
Heat Cool PID
Upper: 4 digits (process value)
Digits
Lower: 4 digits (selectable) Control Method PID
LED Indications Relay ON, Alarm, Manual mode, Tune Cycle Time 0.1 to 100 sec
INPUT SPECIFICATIONS Proportional Gain 0.0 to 400.0°
Thermocouple:
Deadband Programmable (SPLL to SPHL)
J, K, T, R, S, C, E, B, N, L, U, W, Platinel II
Types RTD:
PT100 Alarms
Signal Inputs (DC): Deviation high/low, Absolute high/low,
-5 to 56 mV, 0 to 10 V, 0 to 20 mA Modes Band, Sensor break
Sampling time 200 ms Hysteresis 0.1 to 99.9°
1 / 0.1° for TC/RTD
Resolution Ramp Soak
1/0.1/0.01/0.001 for analog input

Temperature Unit °C / °F selectable Ramp Rate 1 to 9999 °/hr

Indication Accuracy Soak Time 0 to 1440 min

For TC inputs: 0.25% of F.S. ±1° Soft Start Time 0 to 999 min
For R & S inputs: 0.5% of F.S. ±2°
TC / RTD Input (20 min of warm up time for TC input) OPTIONAL FEATURES FOR PID500
For RTD inputs: 0.1% of F.S. ±1° Remote set point input
Cold junction accuracy ± 5°C
±0.5%, ± 1 digit Input Type 0 to 20mA DC / 0 to 10V DC
Signal Input

Control Output (Factory Set) Input Resistance 100 ohm

Relay Range -5% to 105%


5 A@230V AC or 30V DC
-1999 to 9999 with fixed 1o for TC/RTD
SSR 18V DC, 20mA Scale Range and as per resolution selected for
analog input
Current output 0/4 to 20mA DC (max. load :500E) Heater current monitor input

Voltage output 0 to 5/10V DC (min. load :10K) Input 100mA AC, 50 to 400Hz

Alarm Output Max. 2 (max.1 for PR502) Display Scale Range 0 to 999.9

Relay 5A@230V AC or 30V DC Input Resistance 47 ohms

SSR 12V DC (20mA) Accuracy +0.5% F.S +1 digit

Retransmission Output Alarm mode LA / HA / BAND

Current Output 0/4 to 20mA DC (max. load :500E) Over load 150 mA (continuous)

Voltage Output 0 to 5/10V DC (min. load :10K) Motorised Value Input

Update Rate 100 ms Closed Loop Feedback Input Potentiometric


Voltage Input Range: 0 to 10 VDC
FUNCTIONAL SPECIFICATIONS Current Input Range: 4 to 20 mADC

Control Method PID or ON/OFF Motorised Control Mode Bounded / Boundless

Hysteresis 0.1 to 99.9° Manual Motor Control Modes Rest / Run / Up / Down

Proportional Band 0.0 to 400.0° Motor Position Indication (in %) 0.0 to 100.0%

Integral Time 0 to 3600 sec Valve Travel Time 0.1 to 240.0 sec

Derivative Time 0 to 200 sec Control Action (fixed) Output1: Reverse action
Output2: Forward Action

11
Serial Communication (Applicable for PR502/PID500/PID110/PID330) FUNCTIONAL SPECIFICATIONS FOR PR502 (continued)

Interface standard RS485 No. of Steps 16 each

Communication address 1 to 99, maximum of 32 units per line Ramp / Soak Time Range 0.01 to 99.59 hrs : min

Transmission mode Half duplex Target Temperature Range SPLL to SPHL

Supply Voltage 85 to 270V AC/DC


Transmission protocol MODBUS RTU AC: 50 or 60 Hz Optional-24V AC/DC
Temperature Operating: 0 to 50°C
Transmission distance 500 m maximum Storage: -20 to 75°C
Transmission speed 9600, 4800, 2400, 1200, 600, 300 Humidity (non-condensing) 95% RH
bits/sec
FUNCTIONAL SPECIFICATIONS FOR PR502 Weight PID500: 180 gms ; PID110: 230 gms
PID330: 330 gms ; PR502: 170 gms
No. of Profiles 10 Certifications

Dimensions PID500: Diagram B, Page 36 ; PID110: Diagram H(W), Page 36 ; PID330: Diagram G(Y), Page 36 ; PR502: Diagram B, Page 36

Terminal Connections
PR502 PID500 PID110/330

TC + /RTD1

RTD3
TC /RTD2
mV +

-
V RS485

-
mV

+
1 2 3 4 5 6 7 8 9 10

+
SSR1/ MI / CT / R-SP
ANA OP SSR2 SSR3
N L

+
11 12 13 14 15 16 17 18 19 20
-
+
NO1 COM1 NO2 COM2 NO3 COM3

Terminal nos same for PID110. For layout consult factory.

Ordering Information Legend


PID500 A B xx
PID110
Output 1 Output 2 Output 3 / Special functions
PID330 A B xx
0 Relay 0 Relay 00 Only output 1 & 2

Choose from Legend 1 18V DC SSR Drive 1 12V DC SSR Drive 01 Output 3 (relay)
Output 3
2 4-20mA (Current) 02 (12V DC SSR drive)
3 0-10V (Voltage) 03 Communication RS485
Output 3 (relay) +
4 0-5V (Voltage) 04
Communication RS485
Output 3 (12V DC SSR) +
5 0-20mA (Current) 05
Communication RS485
06 CT Input
PID110/330, consult factory.

07 Output 3 (relay) + CT Input


For second analog I/P in

**Second Analog Input


Output 3 (12V DC SSR) +
08 CT Input
Valve positioner type Remote setpoint type
CT Input+
09 Communication RS485
-P Potentiometric f/b input -C 4-20 mA input
Second Analog Input**
-C 4-20 mA f/b input -V 0-10 V input
10 Valve positioner type
Ordering Example -V 0-10 V f/b input
11
Valve positioner type +
Communication RS485
PID500 - 3 - 0 - 01 **NOTE 12 Remote setpoint type
PID500 - Output 1 (Voltage) - Output 2 (Relay) 1) For 24V AC / DC model, add suffix ‘-24’. Remote setpoint type+
13
- Output 3 (Relay) 2) For motoriosed, both the outputs can be Relay only. Communication RS485

Ordering Information(for PR502)


PR502 Legend
A B x A B x
Choose from Legend Output 1 Output 2 Serial Communication

0 Relay 0 Relay 0 No
Ordering Example 1 18V DC SSR Drive 1 12V DC SSR Drive 1 Yes
PR502 - 3 - 0 - 1 2 4-20mA (Current)
PR502 - Output 1 (Voltage) - Output 2 (Relay) 3 0-10V (Voltage)
- Serial Communication (Yes)

12
PID Temperature Controllers
Economy Series ! 4 digit PV, 4 digit SV
! 2 set point
! 4+4 digit
! Single setpoint
selec
! Absolute / Deviation alarm ! 10 A relay output 1C/O
! High performance
! Simple to use
! Best value products in
PID series
48 x 48 48 x 48
PID528 TC518
Description Economical PID Economical PID Terminal Connections
7 segment LED, dual
Display 7 segment LED, dual display PID528
display
Digits 4 + 4 digits 4 + 4 digits

LED Indications Relay ON, Tune Relay ON, Tune

INPUT SPECIFICATIONS

SSR
Types Thermocouple (J,K,T,R,S) / RTD (PT100) Thermocouple (J,K,T,R,S) / RTD (PT100)

Sampling time 250 ms 250 ms

SSR
Resolution 1°/0.1° 1°/0.1°

Fixed oC o
Temperature Unit C / °F selectable
TC518
For TC inputs: 0.25% of F.S. ±1° For TC inputs: 0.25% of F.S. ±1°
Indication Accuracy** For R & S inputs: 0.5% of F.S. ±2° For R & S inputs: 0.5% of F.S. ±2°
(20 min of warm up time for TC input) (20 min of warm up time for TC input) L (+) 1 6
For RTD inputs: 0.1% of F.S. ±1° For RTD inputs: 0.1% of F.S. ±1°
TC + /RTD1
Control Output N (-) 2 7

NO
Relay 5A@230V AC or 30V DC 10A@230V AC or 30V DC 3 8 TC /RTD2
-

SSR
COM
SSR (optional) 18V DC, 20mA 18V DC, 20mA 4 9
RTD3

Current (optional) 4-20mA DC (consult factory)* 5 10


NC

Auxiliary Output Max. 1

Relay 5 A@230V AC or 30V DC

SSR (optional) 12V DC , 20mA

Functional Specifications for Control

Control Method PID or ON/OFF PID or ON/OFF


Ordering Information
Hysteresis 0.1 to 99.9° 0.1 to 99.9°
PID528
Proportional Band 0.0 to 400.0° 0.0 to 400.0°
Legend
Integral Time 0 to 3600 sec 0 to 3600 sec
A
Derivative Time 0 to 200 sec 0 to 200 sec Code Output 1 Output 2

Cycle Time 0.1 to 100.0 sec 0.1 to 100.0 sec 1 Relay Relay

Manual Reset Value -99.9 to 99.9° -99.9 to 99.9° 2 18V DC SSR Drive Relay

Dwell (Soak) Timer 3 4-20mA Relay

Heat-Cool 5 Relay 12V DC SSR Drive

Control Method 6 18V DC SSR Drive 12V DC SSR Drive

Proportional Band-Cool Note: For 24V AC/DC model add suffix '-24'

Cycle Time-Cool
Ordering example
Dead Band PID528 - 2
Functional Specifications for Auxiliary O/P PID528 - 18V DC SSR Drive - Relay
Output1 Output2
Modes Deviation , Absolute

Hysteresis 0.1 to 99.9° TC518


Supply Voltage 85 to 270V AC/DC, 24V AC/DC optional 85 to 270V AC/DC, 24V AC/DC optional
AC: 50 or 60 Hz

Operating: 0 to 50° Operating: 0 to 50° Model Output


Temperature Storage: -20 to 75° Storage: -20 to 75°
TC518 Relay
Humidity (non-condensing) 95% RH 95% RH
TC518-SSR 18V DC SSR Drive
Weight 160 gms 160 gms
*Note: For 24V AC/DC model, add suffix ‘-24’
Certifications

Dimensions Diagram B on page 36 Diagram B on page 36


*NOTE: Not for re-transmission **NOTE: Cold junction calibration accuracy in TC mode ± 5°C
13
Economic Temperature Controllers
! Heat-Cool Control
! Dwell timer ranging-OFF, 0 to 9999 min
! Programmable inputs
! Single setpoint
! Programmable inputs
! Single setpoint
selec
! Programmable inputs
! Single setpoint
! 1 alarm output - Absolute/deviation ! Temperature unit oC / °F selectable ! Temperature unit oC / °F selectable ! Temperature unit oC / °F selectable

NEW TC544A/244AX/344AX NEW TC533AX/233AX/333AX NEW TC513AX/203AX/303AX NEW DTC221A


Economical PID Economical PID Economical PID Economical PID
7 segment LED, dual 7 segment LED, dual 7 segment LED, single 7 segment LED, single
display display display display
4 + 4 digits 3 + 3 digits 3 digits 3 digits

Relay ON, Tune, Soak Time Control output ON Control output ON Control output ON

Thermocouple (J,K,T,R,S) / RTD (PT100) Thermocouple (J,K,T,R,S) / RTD (PT100) Thermocouple (J,K,T,R,S) / RTD (PT100) Thermocouple (J,K,T,R,S) / RTD (PT100)

250 ms 250 ms 250 ms 250 ms


0.1/1° for TC/RTD inputs
Fixed 1o resolution Fixed 1o resolution Fixed 1o resolution
(fixed 1° for R & S type TC input)
o o o o
C / °F selectable C / °F selectable C / °F selectable C / °F selectable
For TC inputs: 0.25% of F.S. ±1° For TC inputs: 0.25% of F.S. ±1° For TC inputs: 0.25% of F.S. ±1° For TC inputs: 0.25% of F.S. ±1°
For R & S inputs: 0.5% of F.S. ±2° For R & S inputs: 0.5% of F.S. ±2° For R & S inputs: 0.5% of F.S. ±2° For R & S inputs: 0.5% of F.S. ±2°
(20 min of warm up time for TC input) (20 min of warm up time for TC input) (20 min of warm up time for TC input) (20 min of warm up time for TC input)
For RTD inputs: 0.1% of F.S. ±1° For RTD inputs: 0.1% of F.S. ±1° For RTD inputs: 0.1% of F.S. ±1° For RTD inputs: 0.1% of F.S. ±1°

5 A @250 VAC / 30 VDC, resistive 10 A@230 VAC or 30 VDC, resistive 10 A@230 VAC or 30 VDC, resistive 10 A@230 VAC or 30 VDC, resistive

12V DC, 50 mA 12V DC, 50 mA 12V DC, 50 mA 12V DC, 50 mA

Max. 1

5 A@230V AC or 30V DC, resistive

12V DC, 50 mA (Optional)

PID or ON/OFF PID or ON/OFF PID or ON/OFF PID or ON/OFF

0.1 to 99.9° 0.1 to 99.9° 0.1 to 99.9° 0.1 to 99.9°

1.0 to 400.0° 1 to 400° 1 to 400° 1 to 400°

0 to 9999 sec 0.0 to 99.9 min 0.0 to 99.9 min 0.0 to 99.9 min

0 to 9999 sec 0 to 200 sec 0 to 200 sec 0 to 200 sec

0.1 to 99.9 sec 0.1 to 99.9 sec 0.1 to 99.9 sec 0.1 to 99.9 sec

-19.9 to 19.9° -19.9 to 19.9° -19.9 to 19.9° -19.9 to 19.9°

OFF, 1 to 9999 min

PID (with auto-tuning)

0.0 to 400.0°

0.1 to 99.9 sec

SPLL to SPHL (Programmable)

Deviation, Absolute

0.1 to 99.9°

85 to 270V AC/DC, 24V AC/DC optional 85 to 270V AC/DC, 24V AC/DC optional 85 to 270V AC/DC, 24V AC/DC optional 85 to 270V AC/DC, 24V AC/DC optional
Operating: 0 to 50° Operating: 0 to 50° Operating: 0 to 50° Operating: 0 to 50°
Storage: -20 to 75° Storage: -20 to 75° Storage: -20 to 75° Storage: -20 to 75°
95% RH 95% RH 95% RH 95% RH
TC544A :142 gms | TC244AX:190 gms TC533A/AX: 129 gms, TC233AX: 180 gms TC513A/AX:129 gms, TC203AX:180 gms DTC221A: 180 gms
TC344AX :252 gms TC333AX: 240 gms TC303AX: 240 gms
Diagram U on page 37 Diagram U on page 37 Diagram U on page 37 Diagram U on page 37
14
selec
Terminal Connections

TC203AX/TC233AX TC303AX/TC333AX DTC221A TC303A


TC+/RTD1 TC+/RTD1
L (+) 1 10 L (+) 1 10
TC+/RTD1
TC+/RTD1 L (+) 1 8
L (+) 1 8 N (-) 2 11 N (-) 2 11
TC-/RTD2 TC-/RTD2
N (-) 2 9
N (-) 2 9 3 12 TC-/RTD2 3 12
TC-/RTD2 RTD3 RTD3
4 13 3 10 4 13
3 10 RTD3
RTD3
5 14 4 11 5 14
4 11
6 15 5 12 + 6 15
NC

- SSR
5 12 +
NO
- SSR

NC + 7 16 +
7 16 6 13

- SSR
NO

- SSR
NO NO
6 13 8 17
8 17 7 14
7 14 COM 9 18
COM 9 18 COM
COM

TC244AX TC344AX TC544A TC513AX/TC533AX

TC+/RTD1 TC+/RTD1
TC+/RTD1 TC+/RTD1 L (+) 1 11 6 L (+) 1 11 6
L (+) 1 8 L (+) 1 10

N (-) 2 11 SSR1+
N (-) 2 9 TC-/RTD2 N( ) 2 7 N( )
TC-/RTD2 - 2 7
NO2 3 12 TC /RTD2 -
3 + 10 RTD3 TC /RTD2
NO2 NO2
- SSR2

RTD3 +
4 13 + NC
- SSR2

COM2 3 8 3 8
11

- SSR2
4 COM2 RTD3
5 14 RTD3
NC2 5 12 + NC2 6 15 4 9 NO
-SSR1

NO1 NO1 COM2 SSR1- 4 9


+
6 13 7 16
- SSR1

NO1
7 14
COM1 8 17 5 12 10 COM1 5 12 10
COM1 NC1 NC1 COM
9 18
- SSR

+
TC513A/TC533A
TC+/RTD1
L (+) 1 11 6

N( ) 2 7 -
TC /RTD2
3 8
RTD3
NO
4 9

5 12 10
COM
- SSR
+

Ordering Information
TC513/TC203/TC303 TC533/TC233/TC333 TC544/TC244/TC344
Part No. Output 1 Part No. Output 1 Part No. Output 1 Output 2

Relay SSR (12V DC) Relay SSR (12V DC) Relay SSR (12V DC) Relay SSR (12V DC)
TC513A TC533A TC544A
TC513A-1 TC533AX TC544A-1
TC513AX TC233AX TC244AX
DTC221A TC333AX TC244AX-1
DTC221A-1 TC344AX
TC203AX TC344AX-1
TC303A
TC303A-1
*Note: For 24V AC/DC model, add suffix ‘-24’
TC303AX
For TC513A/TC513A-1/TC533A/DTC221A/DTC221A-1/TC303A/TC303A-1 24V models are not available

15
Process Indicators
! 4 alarms ! 2 alarms
selec
! Retransmission ! Retransmission ! Scalable Indicator
! Communication

48 x 96 48 x 96 48 x 96
PIC1000N PIC152N PIC101N
Description 4 Alarm outputs, Retransmission, 2 Alarm outputs with retransmission. Very low cost indicator (no output)
Communication
Display 4 digit, 7 segment LED : 0.5” 4 digit, 7 segment LED : 0.5” 4 digit, 7 segment LED : 0.5”

LED Indication Alarm ON (4 Nos) Alarm ON (2 Nos) None

Error Indications Over range/Under range/Open sensor/ Over range/Under range/Open sensor/ Over range/Under range/Open sensor/
TC reverse TC reverse TC reverse
Thermocouple: J, K, T, R, S, C, E, L, U,
Inputs Thermocouple: J, K, T, R, S Thermocouple: J, K, T, R, S
W, N, B, Platinell II
RTD: PT100 RTD: PT100
RTD: PT100, PT1000
Signal Inputs (DC): -5 to 56 mV, 0 to 10V, Signal Inputs (DC): 0 to 56 mV,0 to 10 V,
Signal Inputs (DC): -5 to 56 mV, 0 to 100
0/4 to 20 mA 0/4 to 20 mA
mV, 0 to 10V, 0/4 to 20 mA
Resolution Temperature input: 1/0.1oC / oF ; For Temperature input: 1/0.1oC / oF ; For Temperature input: 1/0.1oC / oF ;
Signal input: 0.001, 0.01, 0.1 & 1. For Signal input: 0.001, 0.01, 0.1 & 1. For Signal input: 0.001, 0.01, 0.1 & 1.
For TC inputs: 0.25% of F.S. ±1° For TC inputs: 0.25% of F.S. ±1° For TC inputs: 0.25% of F.S. ±1°
Accuracy For R & S inputs: 0.5% of F.S. ±2° For R & S inputs: 0.5% of F.S. ±2° For R & S inputs: 0.5% of F.S. ±2°
(20 min of warm up time for TC input) (20 min of warm up time for TC input) (20 min of warm up time for TC input)
For RTD inputs: 0.1% of F.S. ±1° For RTD inputs: 0.1% of F.S. ±1° For RTD inputs: 0.1% of F.S. ±1°
For Signal inputs: ±0.5% of F.S., ± 1 digit For Signal inputs: ±0.5% of F.S., ± 1 digit For Signal inputs: ±0.5% of F.S., ± 1 digit
Alarms 4 nos 2 nos

Alarm Modes High alarm, Low alarm, Band, Fail output High alarm, Low alarm, Band, Fail output
and Fault diagnosis and Fault diagnosis
Hysteresis 0.1 to 99.9 o 0.1 to 99.9 o

Annunciator Programmable Programmable

Reset Action Automatic or Latched Automatic or Latched

Relay Rating 5A @ 250V AC or 24V DC 5A @ 250V AC or 24V DC

Retransmission Output (Optional) 0/4 to 20 mA DC, 0 to 5V DC, 0 to 10V DC 0/4 to 20 mA DC, 0 to 5V DC, 0 to 10V DC

Sensor Supply 24V DC, 30 mA 24V DC, 30 mA 24V DC, 30 mA

Communication RS485 (MODBUS)

Supply Voltage 85 to 270V AC/ DC 85 to 270V AC/ DC 85 to 270V AC/ DC


AC: 50 or 60 Hz Optional - 24V DC Optional - 24V DC Optional - 24V DC
Temperature Operating:0 to 50oC. Storage:-20 to 75oC. Operating:0 to 50oC. Storage:-20 to 75oC. Operating:0 to 50oC. Storage:-20 to 75oC.

Humidity (non-condensing) 95% RH. 95% RH. 95% RH.

Weight 260 gms. 240 gms. 200 gms.

Certifications

Dimensions Refer diagram H(V) on page 36 Refer diagram H(V) on page 36 Refer diagram H(V) on page 36

mV/TC/RTD
Terminal Connections mV/TC/RTD
+ - FOR + - ANALOG +
mV/TC/RTD
-
ANALOG V mA CONFIG
PT100 OUTPUT OUTPUT
+ - A B B’ + - A B B’ + - + -
A B B’

1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10

22 24 22 mA+ V+ mA / V-
24 22 24
-

mA+ V+ mA / V-
sensor supply sensor supply
21 23 21 23
+

21
-
23 - +
+

11 12 13 14 15 16 17 18 N L 11 12 13 14 15 16 17 18 N L 11 12 13 14 15 16 17 18 N L
GND +24V +24V GND
NO1 NO2 NO3 NO4 COM GND +24V
- + - + sensor supply - +
NO1 COM1 NC1 NO2 COM2 NC2

Ordering Information
RETRANSMISSION RETRANSMISSION
MODELS COMMUNICATION MODELS MODELS
OUTPUT OUTPUT
PIC1000-A X X PIC152-A X PIC101N
PIC1000-D-1 0-20mA
PIC1000-D-2 4-20mA PIC152-B-1 0-20mA
X
PIC1000-D-3 0-5V
PIC1000-D-4 0-10V PIC152-B-2 4-20mA
PIC1000-E -
PIC1000-E-1 0-20mA PIC152-B-3 0-5V
PIC1000-E-2 4-20mA
PIC1000-E-3 0-5V
PIC152-B-4 0-10V
PIC1000-E-4 0-10V
Note: For 24V DC model add suffix '-24' 16
Digital / PID Temperature Controllers
Low Cost
selec
DTC503 / 203 / 303
! J, K, PT100 (selectable)
! ON-OFF / Proportional control

PID513 / 213 / 313


! J, K, PT100 (selectable)
! PID Control

48 x 48 72 x 72 96 x 96
DTC503-N / PID513-N DTC203 / PID213 DTC303 / PID313
Description Economical Economical Economical

Digits 3 digits 3 digits 3 digits

LED Indication Output ON Output ON Output ON


User selectable: J (-99 to 750) / User selectable: J (-99 to 750) / User selectable: J (-99 to 750) /
Input Sensor (Range) K (-99 to 999) / PT100 (-99 to 850) K (-99 to 999) / PT100 (-99 to 850) K (-99 to 999) / PT100 (-99 to 850)
Resolution Fixed 1o Fixed 1o Fixed 1o

Setpoints 1 1 1

DTC503: ON/OFF & Time proportional DTC203: ON/OFF & Time proportional DTC303: ON/OFF & Time proportional
Control Modes
PID513: Autotune PID PID213: Autotune PID PID313: Autotune PID

Accuracy ±0.25% of F.S. ±1oC ±0.25% of F.S. ±1oC ±0.25% of F.S. ±1oC
1 (DTC303/PID313: 1 NO,
Outputs 1 (1 C/O) 1 (1 C/O)
DTC303NX: 1C/O)
A) Heat mode A) Heat mode A) Heat mode
Relay Action
B) Cool mode (for DTC503N only) B) Cool mode (for DTC203 only) B) Cool mode (for DTC303 only)

Relay Rating 10A @ 230V AC 10A @ 230V AC 10A @ 230V AC

Optional Output Configuration 12V DC, 20mA 12V DC, 20mA 12V DC, 20mA

Supply Voltage 85 to 270V AC/DC 85 to 270V AC/DC 85 to 270V AC/DC


AC: 50 or 60 Hz 24V AC/DC (optional) 24V AC/DC (optional) 24V AC/DC (optional)
Operating: 0 to 50oC Operating: 0 to 50oC Operating: 0 to 50oC
Temperature
Storage: -5 to 50oC Storage: -5 to 50oC Storage: -5 to 50oC
Humidity (non-condensing) 95% RH 95% RH 95% RH

Weight 140 gms 200 gms 210 gms

Certifications

Dimensions Diagram B on page 36 Refer diagram C on page 36 Refer diagram G(Z) on page 36

Terminal Connections
short for 2 wire
RTD RTD (PT 100)
3 WIRE
RTD

short for RTD short for TC

1 2 3 4 5
TC+ TC- RTD3
RTD1 RTD2

11 Short for config 12

For SSR O/P


+ -
6 7 8 9 10
-N
+

L NO COM NC

NOTE: R - Red, W - White

Ordering Information
Model Description Model Description

DTC503 48 x 48, ON/OFF & Time proportional PID513 48 x 48, Autotune PID

DTC203 72 x 72, ON/OFF & Time proportional PID213 72 x 72, Autotune PID
96 x 96, ON/OFF & Time proportional , PID313 96 x 96, Autotune PID
DTC303 with 1 NO relay output
96 x 96, ON/OFF & Time proportional ,
DTC303NX with 1 C/O relay output ! NOTE
For SSR output models: Add suffix ‘SSR’
For 24V AC/DC models: Add suffix ‘24V’

17
Digital Temperature Controllers
Low Cost
selec
! 2 setpoints ! 2 setpoints
! J, K, PT100 (selectable) ! J, K, PT100 (selectable)
Cooling Controller
! 0.1oC resolution for RTD ! 0.1oC resolution for RTD
! ON-OFF / Proportional control ! ON-OFF / Proportional control ! 0.1oC resolution
! Defrost management
! High & low temperature alarm
! J / K / PT100 versions ! 20 A relay output
! ON-OFF / Proportional control

96 x 96 72 x 72 48 x 48 36 x 72
DTC324 DTC204 TC52 CH403
Programmable, ON/OFF & Time Programmable, ON/OFF & Time Analog temperature controller Controller for cooling applications
proportional mode proportional mode
4 digits 4 digits Dial setting 3 digits
Setpoint lock, Defrost,
Output ON, Alarm ON Output ON, Alarm ON Relay ON, Power ON
Relay ON, Alarm ON
User selectable: J (-99 to 750) / User selectable: J (-99 to 750) / J (200 or 400) / K (200 or 400) /
K(-99 to 1350) / PT100 (-99 to 850.0) K(-99 to 1350) / PT100 (-99 to 850.0) PT100 (200 or 400) NTC
o o o o
1 for TC, 1/0.1 for RTD 1 for TC, 1/0.1 for RTD 1/0.1o

2 2 1 1

Proportional / ON-OFF (Band/ Proportional / ON-OFF (Band/


Hysteresis: 0.1 to 99.9o) Hysteresis: 0.1 to 99.9oC) Time proportional & ON-OFF Control ON-OFF (Hysteresis: 0.1 to 9.9 o)
Cycle time: 1 to 99 sec.) Cycle time: 1 to 99 sec.)

±0.25% of F.S. ±1oC ±0.25% of F.S. ±1oC Setting: ± 3% Repeat: ± 0.5% of F.S. ±0.25% of F.S. ±1oC

2 2 1 2
A) Heat mode A) Heat mode
Heat mode Main, High Alarm, Low Alarm
B) Cool mode B) Cool mode
Main output : 10A @ 230V AC or 20A;
Set 1: 10A @ 230V AC Set 1: 10A @ 230V AC Alarm output : SSR drive 12V DC, 10mA
5A@230V AC
Set 2: 5A @ 230V AC Set 2: 5A @ 230V AC or Relay 5A @ 230V AC

12 VDC, 20 mA 12V DC, 20 mA


85 to 270 VAC/DC 85 to 270V AC/DC 85 to 270V AC/DC
Optional: 24 VAC/DC Optional: 24V AC/DC 230V AC Optional: 24V AC/DC
Operating: 0 to 50oC ; Operating: 0 to 50oC o
Operating: 0 to 50 C Operating: 0 to 50oC
Storage"- -5 to 50oC. Storage: -5 to 50oC Output to drive SSR.
12VDC Storage: -5 to 50oC Storage: -5 to 50oC
95% RH 95% RH 95% RH 95% RH

230 gms 230 gms 130 gms 110 gms

Refer diagram G(Z) on page 38 Refer diagram C on page 36 Refer diagram B on page 36 Refer diagram F on page 36

NO COM NC ALARM SENSOR


+ - N L

1 2 3 4 5 6 7 8 9 10 11 12
+ - - +
FOR COM NO
SSR (VALID FOR 20A)

Specifications for NTC Sensor (TSP04)


Sensor Thermocouple Nominal
Type Range (OC) Resistance
NTC probe -40 to +100 10 K ohms
@25OC

Ordering Information Ordering Information (for TC52)


Product Name
PIC1000N-A Order Code
PIC1000N-A Description
PIC1000N-A Model Range Sensor Supply
o
DTC204 DTC204-2 Relay Output 200 - 0 to 200 C J / K / PT100 230V AC
TC52
o
DTC324 DTC324 Relay Output 400 - 0 to 400 C J / K / PT100 230V AC
Main O/P : 10A Relay
CH403-1
CH403
Alarm O/P : 12V DC, 10 mA Ordering Example
Main O/P : 20A Relay
CH403-2 Alarm O/P : None TC52 - 400 - J - 230 ! NOTE
Main O/P : 10A Relay
CH403-3 o For SSR output models: Add suffix ‘SSR’
Alarm O/P : 5A Relay TC52 (model) - 0 - 400 C - J Type Thermocouple
- 230V AC supply For 24V AC/DC models: Add suffix ‘24V’

18
Digital Timers selec
! Low cost ! Multifunction ! Preset
! Single setpoint ! Multirange ! 2 C/O output
! 2 C/O output ! 2 setpoints

48 x 48 48 x 48 48 x 48

XT543 XT5042 XT56N


Description Economical, multifunction programmable Multifunction, dual display High accuracy, push wheel setting

Display Upper: 7 segment red LED; 0.5”


7 segment LED; Height: 0.5” 7 segment LED; Height: 0.3”
Lower: 7 segment green LED ; 0.3”
Digits 3 digits Upper: 4 digits 3 digits
Lower: 4 digits
Time Setting Front keypad Front keypad Pushwheel

No of Channels

ON delay / Interval delay / ON delay / Interval delay / Cyclic ON first /


Operating Modes Cyclic ON first / Cyclic OFF first Cyclic OFF first / Forward-pause-reverse/ ON delay / Interval
( refer page 35 for timing diagrams) instantaneous + delayed / timer / batch
( refer page 35 for timing diagrams)

Setpoints 1 2 1

9.99 / 99.9 / 999 sec, 9:59 min:sec 99.99 / 999.9 / 9999 sec, 99:59 min:sec, 9.99 / 99.9 / 999 sec, 99.9 / 999 min,
Range 999.9 / 9999 min, 99:59 hr:min,
99.9 / 999 min, 9:59 hr:min, 99.9 / 999 hr 99.9 hr
999.9 / 9999 hr
Counting Direction Down Up / down Down

Start Input Gate / pulse start (programmable) Gate / pulse start (programmable) Pulse start

Accuracy ±0.5% of F.S. or 50 ms ±0.05% of F.S. or 50 ms ±0.05% of F.S. or 50 ms

Reset Front, Remote, Front, Remote, Front, Remote, Power interruption


Power interruption Power interruption (programmable)
Memory 10 years

Configuration Lock Via rear terminals Password protected

LED Indications Relay status Relay status, sec, min & hr Relay status

Output 2 C/O (DPDT) 2, each 1 NO 2 C/O (DPDT)

Relay Rating 5A @ 230V AC 5A @ 230V AC 5A @ 230V AC

Supply voltage 85 to 270V AC/DC 85 to 270V AC/DC, 24V DC (optional) 85 to 270V AC/DC
AC: 50 or 60 Hz

Temperature Operating: 0 to 50°C Operating: 0 to 50°C Operating: 0 to 50°C


Storage: -5 to 50°C Storage: -5 to 50°C Storage: -5 to 50°C
Humidity (non-condensing) 95% RH 95% RH 95% RH

Weight 130 gms 175 gms 140 gms

Certifications

Dimensions Refer diagram B on page 36 Refer diagram B on page 36 Refer diagram B on page 36

Terminal Connections

Ordering Code XT543N XT5042 XT56N

19
selec
PT380 - 8 Channel Sequential Timer
! Flexibility of programming each channel separately
! Preset ! Preset ! Sequential / Parallel operation
! 2 C/O output ! 2 C/O output ! Cascade output for channel expansion

72 x 72 96 x 96 96 x 96

XT264 XT364 PT380


Description Economical, pushwheel setting Economical, pushwheel setting Sequential timer

Display 7 segment LED; Height: 0.5” 7 segment LED; Height: 0.5” 7 segment LED; Height: 0.3”

Digits 3 digits 3 digits 2 + 4 digits

Time Setting Pushwheel Pushwheel Front keypad

No of Channels 8 channels
ON delay, Interval, Cyclic ON first,
Operating Modes ON delay / Interval ON delay / Interval Cyclic OFF first (start up delay & no. of
cycles programmable for cyclic mode)
( refer page 35 for timing diagrams)

Setpoints 1 1 8

Range 9.99 / 99.9 / 999 sec, 99.9 / 999 min, 9.99 / 99.9 / 999 sec, 99.9 / 999 min, 99.99, 999.9, 99:59 min:sec,
99.9 hr 99.9 hr 99:59 hr:min, 999.9 hr

Counting Direction Down Down Up

Start Input Pulse start Pulse start Start, Hold


±0.5% of setting or 50 ms,
Accuracy ±0.5% of F.S. or 50 ms ±0.5% of F.S. or 50 ms
whichever is greater
Reset Front, Remote, Power interruption Front, Remote, Power interruption Front, remote, on power interruption

Memory 10 years

Configuration Lock via rear terminals


Relay status, Cascade O/P , Time range,
LED Indications Relay status Relay status
ON/OFF time, Timing in progress
Output 2 C/O (DPDT) 2 C/O (DPDT) 8 nos., NO with single common

Relay Rating 5A @ 230V AC 5A @ 230V AC 5A @ 230V AC

Supply voltage 85 to 270V AC/DC 85 to 270V AC/DC 85 to 270V AC/DC


AC: 50 or 60 Hz

Operating: 0 to 50°C Operating: 0 to 50°C Operating: 0 to 50°C


Temperature
Storage: -5 to 50°C Storage: -5 to 50°C Storage: -20 to 75°C
Humidity (non-condensing) 95% RH 95% RH 95% RH

Weight 200 gms 230 gms 350 gms

Certifications

Dimensions Refer diagram C on page 36 Refer diagram G(Z) on page 38 Refer diagram G(X) on page 36

Terminal Connections
To GND & STRT
of timer2

1 2 3 4 5 6 7 8 9
STRT HOLD RST CONFIG +24V GND CAS NO1 NO2

N L
10 11 12 13 14 15 16 17 18
NO3 NO4 NO5 NO6 NO7 NO8 COM
- +

Ordering Code XT264-3 XT364-3 PT380

20
Digital Timers
Multifunction Multi range timers
selec

NEW 48 x 48 NEW 72 x 72 NEW 96 x 96

XT546 XT246 XT346


Description Multifunction Dual Display Multifunction Dual Display Multifunction Dual Display

Display 7 segment LED, 3+3 digits 7 segment LED, 3+3 digits 7 segment LED, 3+3 digits
Height : Upper display : 0.39" Height : Upper display : 0.56" Height : Upper display : 0.56"
Lower display : 0.29" Lower display : 0.4" Lower display : 0.4"

Time Setting Front keypad Front keypad Front keypad

ON delay, Interval, Cyclic ON first, ON delay, Interval, Cyclic ON first, ON delay, Interval, Cyclic ON first,
Operating Modes Cyclic OFF first Cyclic OFF first Cyclic OFF first
(Refer page 35 for timing diagram) (Refer page 35 for timing diagram) (Refer page 35 for timing diagram)

Setpoints 1 1 1

9.99 / 99.9 / 999 sec 9.99 / 99.9 / 999 sec 9.99 / 99.9 / 999 sec
Range 9.59 min : sec, 99.9 / 999 min 9.59 min : sec, 99.9 / 999 min 9.59 min : sec, 99.9 / 999 min
9.59 hour : min, 99.9 / 999 hour 9.59 hour : min, 99.9 / 999 hour 9.59 hour : min, 99.9 / 999 hour

Counting Direction Down Down Down

Start Input Pulse, Gate (Programmable) Pulse, Gate (Programmable) Pulse, Gate (Programmable)

Setting : ±0.05% of set time or 50 ms Setting : ±0.05% of set time or 50 ms Setting : ±0.05% of set time or 50 ms
Accuracy (whichever is greater) (whichever is greater) (whichever is greater)
Repeat : ±0.05% Repeat : ±0.05% Repeat : ±0.05%
Reset Front, Remote, Power interruption Front, Remote, Power interruption Front, Remote, Power interruption

Memory 10 years 10 years 10 years

Configuration Lock Through front keypad Through front keypad Through front keypad

LED Indications Relay status, Seconds, Minutes, Hours Relay status, Seconds, Minutes, Hours Relay status, Seconds, Minutes, Hours

Output 2:1 C/O (SPDT) 2:1 C/O (SPDT) 2:1 C/O (SPDT)

Relay Rating 5A @ 250V AC 5A @ 250V AC 5A @ 250V AC

Supply voltage 85 to 270V AC, 24V AC/DC 85 to 270V AC, 24V AC/DC 85 to 270V AC, 24V AC/DC
AC : 50/60 HZ

Temperature Operating: 0 to 50°C Operating: 0 to 50°C Operating: 0 to 50°C


Storage: -20 to 75°C Storage: -20 to 75°C Storage: -20 to 75°C
Humidity (non-condensing) 95% RH 95% RH 95% RH

Weight 140 gms 190 gms 240 gms

Certifications

Dimensions Refer diagram U on page 37 Refer diagram U on page 37 Refer diagram U on page 37
L
Terminal Connections L START + 1 10 START
+ 1 8
- 2 11 COM
L
1 11 6 COM - COM N
+ 2 9
N 3 12
START RST
- 2 7 RST 3 10 RST 4 13
N

NO1 NO2 4 11 5 14
3 8
NO1 NO2 6 15
COM1 COM2
5 12
NO1 NO2
4 9 COM2 7 16
COM1 6 13
COM1 8 17 COM2
5 12 10 NC1 7 14
NC1 NC2 NC2 NC1 9 18
NC2

Ordering Code XT546 / XT546-24V XT246 / XT246-24V XT346 / XT346-24V

21
22.5mm
Din Rail Timers
selec
800 Series
! Slim, space saving design
! Din rail / screw mounting
! Finger guards for safety
! Wide range of models

800XU 800XA 800M 800S 800XC

Description 2 functions, 12 ranges 2 functions, 8 ranges 2 functions, 12 ranges Lowest cost, single range, Cyclic with unequal ON time
universal voltage universal voltage (economical) single function & OFF time
+1
Modes ON delay / Interval ON delay / Interval ON delay / Interval ON: ON delay Cyclic ON first or OFF first
30S: 30 sec, 60S: 60 sec 1 / 10 sec / min / hr for both
Time Ranges 1 / 3 / 10 / 30 sec / min / hr 3 / 10 / 30 / 60 sec / min 1 / 3 / 10 / 30 sec / min / hr (factory set) ON & OFF time
Accuracy Setting: ± 5% of F.S. ; Setting: ± 5% of F.S. ; Setting: ± 5% of F.S. ; Setting: ± 5% of F.S. ; Setting: ± 5% of F.S.,
Repeat: ±0.5% or 50 ms Repeat: ±0.5% or 50 ms Repeat: ±0.5% or 50 ms Repeat: ±0.5% Repeat: ±0.5% or 50 ms
Reset On interruption of power ; On interruption of power ; On interruption of power ; On interruption of power ; On interruption of power ;
Reset time < 100 ms Reset time < 100 ms Reset time < 100 ms Reset time < 100 ms Reset time < 100 ms
LED Indications Power ON, Relay ON Power ON, Relay ON Power ON, Relay ON Power ON, Relay ON Power ON, Relay ON

Output contacts 2 C/O (DPDT) 2 C/O (DPDT) 2 C/O (DPDT) 1: 1 C/O SPDT 2 C/O (DPDT)

Relay rating 5A@230V AC / 5A@230V AC / 5A@230V AC / 5A@230V AC / 5A@230V AC /


24V DC resistive 24V DC resistive 24V DC resistive 24V DC resistive 24V DC resistive
Supply voltage 20 to 240V AC 20 to 240V AC 230: 230V AC 12: 12V DC 20 to 240V AC
AC: 50 or 60 Hz
12 to 240V DC 12 to 240V DC 110: 110V AC 12 to 240V DC
230: 230V AC
415: 415V AC (factory set)
Operating: 0 to 50°C Operating: 0 to 50°C Operating: 0 to 50°C Operating: 0 to 50°C Operating: 0 to 50°C
Temperature
Storage: -20 to 75°C Storage: -5 to 50°C Storage: -5 to 50°C Storage: -5 to 50°C Storage: -5 to 50°C
Humidity
(non-condensing) 95% RH 95% RH 95% RH 95% RH 95% RH

Weight 100 gms 100 gms 100 gms 70 gms 110 gms

Certifications

Dimensions Refer to diagram L on page 36

Terminal
Connections

NOTE: Relay2 applicable for


2 C/O models only.

Ordering Code 800XU 800XA 800M-230 800S-1-ON-30S-230 800XC


Supply Voltage 230V AC 1 C/O, On delay, 30 sec, 230V AC
800S-1-ON-60S-230
1 C/O, On delay, 60 sec, 230V AC

! IMPORTANT INFORMATION
+1 For detailed explanation of timing diagrams, refer to
page no. 33 & 34.

22
Special function timers
800XMR
selec
Forward - Pause - Reverse timer
Special timer for repetitive forward and 800POD 800SD-2 STAR DELTA TIMER
reverse motion of motor with intermediate True power off delay timer Special timer for star delta changeover.
pause timing. For star-delta starting of 3 Ø induction motors

N R R

800XMR 800POD 800SQ-A 800SD-2


Description Forward-pause- True power OFF delay timer Low cost, 8 ranges, Star delta timer
reverse dual voltage
+1
Modes Forward-pause-reverse True power OFF delay ON delay / Interval (factory set) Star-Delta

Time Ranges 1 / 2/ 4 / 8 min ( ON time) 60: 60 sec, 180: 180 sec 3 / 10 / 30 / 60 sec / min Runup time range: 30/60 sec
10 / 20 / 40 / 80 sec (pause time) (factory set) (factory set) Change Over: 50/100 msec
Accuracy Setting: ± 5% of F.S. ; Setting: ± 10% of F.S. ; Setting: ± 5% of F.S. ; Setting: ± 5% of F.S. ;
Repeat: ±0.5% or 50 ms Repeat: ±2% or 100 ms Repeat: ±0.5% Repeat: ±0.5% or 50 ms
Reset On interruption of power ; On interruption of power ; On interruption of power ; On interruption of power ;
Reset time < 100 ms Reset time < 100 ms Reset time < 100 ms Reset time < 100 ms
Star Relay ON
LED Indications Relay1 ON, Relay2 ON Power ON Power ON, Relay ON
Delta Relay ON
Output contacts 1 C/O each 2 C/O (DPDT) 1 C/O (SPDT) 1 C/O relay each for star
for forward & reverse & delta
Relay rating 5 A@230 VAC / 24V DC resistive 2.5 A@250 VAC / 28 VDC 5 A@230 VAC / 24V DC resistive 5 A@230 VAC, resistive
resistive
Supply voltage 20 to 240 VAC 110 to 240 VAC/DC 230: 230 VAC & 24 VAC/DC 230: 230 VAC, 415: 415 VAC,
AC: 50 or 60 Hz 12 to 240 VDC 110: 110 VAC & 24 VAC/DC 110: 110 VAC (factory set)

Temperature Operating: 0 to 50°C Operating: 0 to 50°C Operating: 0 to 50°C Operating: 0 to 50°C


Storage: -5 to 50°C Storage: -5 to 50°C Storage: -5 to 50°C Storage: -20 to 75°C
Humidity
(non-condensing) 95% RH 95% RH 95% RH 95% RH

Weight 100 gms 110 gms 115 gms 90 gms

Certifications

Dimensions Refer to diagram L on page 36

Terminal
Connections A1 25
15 26
relay

Rly 1
COM
S NC
Y relay

U NO
P NO
COM
Rly 2 P NC
L
Y
16 28
18 A2

Ordering Code 800XMR 800POD-60 800SQ-A-230 800SD-2-230


Time Range: 60 seconds Supply Voltage 230V AC & 24V AC/DC Supply Voltage 230V AC
800POD-180 800SQ-A-110 800SD-2-415
Time Range: 180 seconds Supply Voltage 110V AC & 24V AC/DC Supply Voltage 415V AC
800SD-2-110
Supply Voltage 110V AC

! IMPORTANT INFORMATION
+1 For detailed explanation of timing diagrams, refer to
page no. 33 & 34 .

23
17.5mm Din Rail Timers
642 Series
selec
! Slim, space saving
design
! Din rail / screw
mounting
! Finger guards for
safety
642UX 642SQ 642VTR-3

Description 13 functions, 8 ranges Low cost, 4 ranges, 2 voltages Under voltage time relay
Universal voltage
+1 13 functions ON delay / Interval Under voltage time relay ( ON delay )
Modes
( ON delay, Interval delay, Pulse output, (refer pg 37 for timing diagrams)
Repeat cycle equal(OFF first),
Repeat cycle equal(ON first), delay on
break,Delay on Make with Totalize
Delay on make / Delay on break,
Interval after break,
Interval with Totalize, Interval on Make /
Interval on Break, Single shot,
Retriggerable single shot)
Time Ranges 3 / 10 / 30 sec / min, 3 /10 hr 15 / 60 sec, 7.5 / 60 min 5 to 15 min
Setting: ± 5% of full scale ; Setting: ± 5% of full scale ; Setting: ± 5% of full scale ;
Accuracy
Repeat: ±0.5% or 50 ms Repeat: ±0.5% or 50 ms Repeat: ±0.5% or 50 ms
On interruption of power ; On interruption of power ; On interruption of power ;
Reset
Reset time < 100 ms Reset time < 100 ms Reset time < 200 ms
LED Indications Power ON, Relay ON Power ON, Relay ON Power ON, Relay ON

Output contacts 1 C/O (SPDT) 1 C/O (SPDT) 1 C/O (SPDT)

Relay rating 5 A@230 VAC / 5 A@230 VAC / 5 A@230 VAC /


24V DC resistive 24V DC resistive 24V DC resistive
Supply voltage 20 to 240 VAC 230 VAC & 24 VAC/DC 3 Ø / 4 w 380-415 VAC,
AC: 50 or 60 Hz 12 to 240 VDC 110 VAC & 24 VAC/DC P-P (50/60Hz)
Operating: 0 to 50°C Operating: 0 to 50°C Operating: 0 to 50°C
Temperature
Storage: -20 to 75°C Storage: -20 to 75°C Storage: -20 to 75°C
Humidity (non-condensing) 95% RH 95% RH 95% RH

Weight 80 gms 50 gms 60 gms

Certifications

Dimensions Refer to diagram K on page 36

Terminal Connections

R
A1 25 Y
A1 25 B
15 26
15 26 A1 25
8 9
10

10
COM 6
7
8 9

S 15 26
10

5
4
3 0
COM 6
5
7 10
N
0

U 2 1 4
3 0
0

2 1
Control
10

60
NO NC
P Contact NO NC 30

24 230 0
0

P (Y)
L V VAC
Y
16 28 16 28
COM
18 A2 18 A2 16 28
NO NC 18 A2

Ordering Code 642 UX 642 SQ-230 642 VTR-3


Supply Voltage 230V AC & 24V AC/DC Supply Voltage 415V AC (phase to phase)
642 SQ-110
Supply Voltage 110V AC & 24V AC/DC

! IMPORTANT INFORMATION
+1 For detailed explanation of timing diagrams, refer to
page no. 33 & 34.

24
17.5mm Din Rail Timers
600 Series
selec
! Slim, space saving design
! Din rail mounting
Phase
Sequence
Relay
NEW NEW NEW

600ST 600XU 600PSR

Description Single function 13 functions Phase sequence


10 time ranges 10 time ranges Relay

Modes On delay On delay (A), Interval (B) Phase Failure Trip:


Pulse output (C) <70% of nominal voltage
Cyclic equal ON first (D) (<280V AC)
Cyclic equal OFF first (Di) Detect phase Sequence/Phase Reversed:
Delay on break (E) Yes
Delay with Totalise (Ai) Hysteresis:
Delay on make/Delay on break(F) 2% (factory set)
Interval after break (H) Response Time:
Interval with totalise (Bi) 100 msec max.
Single shot (I) Power On Delay:
Retriggerable Single shot (J)
100 msec
Latching relay (K)

Time Ranges 1 / 3 / 10 / 30 Sec/min 1 / 3 / 10 / 30 Sec/min


1 / 3 hr 1 / 3 hr

Accuracy Setting: ± 5% of full scale ; Setting: ± 5% of full scale ; ±3% of F.S.


Repeat: ±0.5% Repeat: ±0.5% (F.S. = Full Scale)

Reset On interruption of power; On interruption of power; Auto reset on removal of


Reset time < 100 msec Reset time < 100 msec fault condition
LED Indications Power ON, Relay ON Power ON, Relay ON Relay ON

Output contacts 1 C/O (SPDT) 1 C/O (SPDT) 1 C/O (SPDT)

Relay rating NO/5A, NC/3A @ 250V AC NO/5A, NC/3A @ 250V AC NO/5A, NC/3A @ 250V AC

Supply voltage 240V AC & 24V AC/DC 20-240V AC/DC 3Ø/3W


AC : 50/60 HZ 280 to 528 VAC
P-P

Temperature Operating: 0 to 50oC Operating: 0 to 50oC Operating: 0 to 50oC


Storage: -20 to 75oC Storage: -20 to 75oC Storage: -20 to 75oC

Humidity (non-condensing) 95% RH 95% RH 95% RH


Weight 71gms 80 gms 74 gms

Certifications

Dimensions Refer to diagram V on page 37 Refer to diagram V on page 37 Refer to diagram V on page 37

Terminal Connections

+ 24V - R
Y
B
A1 A2
A1 A2 L1
25 L2 L3
R
R
R
Control
Contact Y1
ON
ON NC
15 Y1 16
15
16 18 15 18
16 18 COM NO
NC NO
NC NO

COM
COM

! IMPORTANT INFORMATION
+1 For detailed explanation of timing diagrams, refer to page no. 33 & 34.

25
Plug / Panel Mount Timers
55 Series
selec
! Compact size
! Plug / panel mounting
! Wide range of models

48 x 48 48 x 48
48 x 48 48 x 48
55XC 55XU 55M 55ES
Cyclic with unequal 2 functions, 12 ranges,
Description 2 functions, 12 ranges Low cost, 8 range dual voltage
ON & OFF time universal voltage
+1
Modes Cyclic ON first or OFF first ON delay / Interval ON delay / Interval ON delay / Interval
P8- 8 Pin plug P8- 8 Pin plug P8- 8 Pin plug P8- 8 Pin plug
Base Type
T- Screw terminal T- Screw terminal T- Screw terminal T- Screw terminal
1 / 10 sec / min / hr for both
Time Ranges 1 / 3 / 10 / 30 sec / min / hr 1 / 3 / 10 / 30 sec / min / hr 3 /10 / 30 / 60 sec / min
ON time & OFF time
Setting: ± 5% of F.S. ; Setting: ± 5% of F.S. ; Setting: ± 5% of F.S. ; Setting: ± 5% of F.S. ;
Accuracy
Repeat: ±0.5% or 50 ms Repeat: ±0.5% or 50 ms Repeat: ±0.5% or 50 ms Repeat: ±0.5% or 50 ms
Reset On interruption of power ; On interruption of power ; On interruption of power ; On interruption of power ;
Reset time < 100 ms Reset time < 100 ms Reset time < 100 ms Reset time < 100 ms
LED Indications Power ON, Relay ON Power ON, Relay ON Power ON, Relay ON Power ON, Relay ON

Output contacts 2 C/O (DPDT) 2 C/O (DPDT) 2 C/O (DPDT) 1 C/O (SPDT)

Relay rating 5A@230V AC / 5A@230V AC / 5A@230V AC / 5A@230V AC /


24V DC resistive 24V DC resistive 24V DC resistive 24V DC resistive
Supply voltage 20 to 240V AC 20 to 240V AC 230: 230V AC & 24V AC/DC
230: 230V AC
AC: 50 or 60 Hz 12 to 240V DC 12 to 240V DC 110: 110V AC & 24V AC/DC
Temperature Operating: 0 to 50°C Operating: 0 to 50°C Operating: 0 to 50°C Operating: 0 to 50°C
Storage: -5 to 50°C Storage: -5 to 50°C Storage: -5 to 50°C Storage: -5 to 50°C
Humidity
(non-condensing) 95% RH 95% RH 95% RH 95% RH

Weight 80 gms 100 gms 90 gms 80 gms

Certification

Dimensions Refer to diagram A on page 36

Terminal
8 pin plug-in type 8 pin plug-in type 8 pin plug-in type
Connections NC
NC1 NC2
4 5 4 5
3 6 24V
3 6 NO
NO1 NO2
2 7
2 7
1 8
1 8 COM
COM1 COM2
+
L N SU PP LY

Terminal type Terminal type Terminal type


1 2 3 4 5 1 2 3 4 5
NC1 NO1 NO2 NC1 NO1
COM1 NC2 COM2 COM1
11 12 11 12

6 7 8 9 10 6 7 8 9 10
-N -
L L -
N
+

24V

Ordering Code 55XC - Base type 55XU - Base type 55M - Base type - Supply voltage 55ES - Base type - Supply voltage

Base type Base type Base type Base type


P8 - 8 pin plug P8 - 8 pin plug P8 - 8 pin plug P8 - 8 pin plug
T - Screw Terminal T - Screw Terminal T - Screw Terminal
P11 - 11 pin plug
T- Screw Terminal Supply Voltage Supply Voltage
230 : 230V AC 230 : 230V AC & 24V AC/DC
110 : 110V AC & 24V AC/DC

! IMPORTANT INFORMATION
+1 For detailed explanation of timing diagrams, refer to
page no. 33, 34

26
Digital Counters
Totalisers
selec
! Self powered
! 6 digits ! 6 digits ! Long battery life
! Inbuilt sensor supply ! Inbuilt sensor supply ! Contact / AC input

36 x 72 48 x 96 24 x 48

XC410 XC10D LXC900


Description 6 digit totaliser 6 digit totaliser LCD Counter

Display Seven segment LED; Height: 0.3” Seven segment LED; Height: 0.5” Liquid crystal display, Height: 8 mm

Digits 6 digits 6 digits 8 digits

Sensor Type NPN / PNP NPN / PNP


Voltage pulse (3 to 30V DC) from Voltage pulse (3 to 30V DC) from
V: Voltage pulse of 24 to 260V AC
Input Type Proximity switches, Solid state devices, Proximity switches, Encoders, C: Potential free input
Potential free contact encoder Solid state devices, Potential free contact
a) 0 to 20Hz a) 3Hz b) 30Hz a) 14Hz
Input Speed
b) 0 to 1kHz c) 1kHz b) 100Hz

Operating Modes

Setpoints

Range 999999 counts 999999 counts 99999999 counts

Counting Direction Up Up Up

Scale Factor

Accuracy

Reset Front, Remote Front, Remote Front, Remote

Memory Retention Yes Yes Yes

Sensor Supply Inbuilt, 12V DC, 30mA Inbuilt, 12V DC, 30mA

LED Indications

Output

Relay Rating

Supply voltage 90 to 270V AC/DC, 24V AC/DC (optional) 90 to 270V AC/DC Battery powered
AC: 50 or 60 Hz

Operating: 0 to 50°C Operating: 0 to 50°C Operating: 0 to 50°C


Temperature
Storage: -5 to 50°C Storage: -5 to 50°C Storage: -20 to 75°C
Humidity (non-condensing) 95% RH 95% RH 95% RH

Weight 110 gms 200 gms 40 gms

Certifications

Dimensions Refer to diagram F on page 36 Refer to diagram H(V) on page 36 LXC900:Refer diagram N on page 36

Terminal Connections Voltage Input


INP COM RST EN

SENSOR
1 2 3 4 5 6 7 8
SELECTION VERY RESET
NPN PNP +12V RST COM SLOW SLOW COM ENABLE

24 - 260V AC
1 2 3 4 5 6 7 8 9 10
CNT SPEED
22 SELECTION 24 Contact Input
21 23 INP RST COM SPD EN

11 12 13 14 15 16 17 18 N L
1 2 3 4 5 6 7 8
- +
Contact Input

Ordering Code XC410 XC10D LXC 900- C : 24 x 48, Contact input


LXC 900- V : 24 x 48, Voltage input

27
Digital Counters
Programmable / Preset
! 6 digit counter; 5 digit
RPM indicator
! 2 setpoints ! 6 digit counter; 5 digit
! Programmable input scaling RPM indicator ! Preset counter
! Multifunction timer cum counter
! Up, down, quadrature & bi- ! 2 setpoints ! Thumbwheel setting
! 2 configurable setpoints
Directional ! Programmable input scaling ! Auto reset
! Programmable input scaling
! Up, down, quadrature & bi- ! Battery backup
! Batch counting
Directional

72 x 72 48 x 96 48 x 48 72 x 72
XC200NX XC1200 XTC5400 XC22B
Multi function, quadrature input Multi function, quadrature input
Multi-function, multi-range timer counter 4 digit preset counter
2 setpoints 2 setpoints
Upper: Seven segment red LED
Seven segment LED; Height: 0.3” Seven segment LED; Height: 0.5” Seven segment LED; Height: 0.5”
Lower: Seven segment green LED
Total: 6 digits Total: 6 digits Upper: 4 digits 4 digits
Rate: 5 digits Rate: 5 digits Lower: 4 digits
NPN NPN NPN / PNP NPN / PNP
Voltage pulse (3 to 30V DC) from Voltage pulse (3 to 30V DC) from Voltage pulse (3 to 30V DC) from Voltage pulse (3 to 30V DC) from
proximity switches, Encoders, proximity switches, Encoders, proximity switches, Encoders, proximity switches, Encoders,
Solid state devices, Potential free contact Solid state devices, Potential free contact Solid state devices, Potential free contact Solid state devices, Potential free contact
a) 0 to 30Hz b) 0 to 2.5kHz a) 0 to 30Hz b) 0 to 2.5kHz a) 3Hz a) 0 to 30Hz
c) 0 to 5kHz (for up & down mode only) c) 0 to 5kHz (for up & down mode only) b) 30Hz c) 5kHz b) 0 to 2kHz
Timer: ON delay, Interval, Cyclic ON first,
ON delay / Interval delay / ON delay / Interval delay / Cyclic OFF first, Batch
ON delay / Interval delay / Auto reset
Auto reset / Time pulse repeat Auto reset / Time pulse repeat Counter: ON delay, Interval, Auto reset,
Time pulse Repeat, Batch

2 2 2 1

Count: Selectable least count Count: Selectable least count Timer: 99.99 / 999.9 / 9999 sec
0.0001, 0.001, 0.01, 0.1 & 1 0.0001, 0.001, 0.01, 0.1 & 1 99.59 min:sec, 999.9 / 9999 min
9999
Rate: Auto ranging 4.00 to 99999 Rate: Auto ranging 4.00 to 99999 99.59 hr:min, 999.9 / 9999 hr
RPM or RPH mode RPM or RPH mode Counter: -999 to 9999 counts

Timer: Down
Up, Down, Bidirectional, Quadrature Up, Down, Bidirectional, Quadrature Up
Counter: Up / down
n n n
0.00001 to 9.99999 x 10 0.00001 to 9.99999 x 10 0.001 to 9.999 x 10
n= -5, -4, -3, -2, -1, 0, 1, 2 n= -5, -4, -3, -2, -1, 0, 1, 2 n= -3, -2, -1, 0, 1, 2
Rate: 0.05% ± 2 counts Rate: 0.05% ± 2 counts Time: ± 0.05% of setting
Counter: ± 0 counts
Front (user selectable), Remote Front (user selectable), Remote Front, Remote, Power interruption Front, Remote, Auto (optional)

Yes Yes Yes Yes


Inbuilt, 12V DC, 30mA Inbuilt, 12V DC, 30mA 12V DC, 30mA
Inbuilt, 12V DC, 30mA
(short circuit protected) (short circuit protected) (short circuit protected)
Relay 1, Relay 2 Relay 1, Relay 2 Relay1, Relay2, sec, min, hr Relay ON

2, 2 Relays each 1 C/O 2, 2 Relays each 1 C/O 2, 2 Relays each 1 NO 2 C/O (DPDT)

5A @ 230V AC/ 24V DC 5A @ 230V AC/ 24V DC 5A @ 230V AC 5A @ 230V AC


85 to 270V AC/DC
85 to 270V AC/DC 85 to 270V AC/DC 230: 230V AC, 110: 110V AC
Optional: 24V DC
Operating: 0 to 50°C Operating: 0 to 50°C Operating: 0 to 50°C Operating: 0 to 50°C
Storage: -5 to 50°C Storage: -5 to 50°C Storage: -20 to 75°C Storage: -5 to 50°C
95% RH 95% RH 95% RH 95% RH

220 gms 230 gms 170 gms 320 gms

Refer diagram C on page 36 Refer diagram H(V) on page 36 Refer diagram B on page 36 Refer diagram C on page 36

XC22B-4-230 : Without memory


XC200NX XC1200 XTC5400, XTC5400-24 (24V DC) XC22B-4-AR-M1-230 : With memory and Auto reset

28
Rate Indicators selec
! Auto ranging RPM
indicator ! RPS, RPM, RPH indication
! Measures upto 9999 RPM ! Scalable input ! Scalable input
! Inbuilt sensor supply ! Measures upto 9999 RPM ! High & low alarm
! Input speed upto 3.5 kHz ! Programmable alarm delay
! 6 digit count
! Measures upto ! 4 digit rate
9999 RPM ! Scalable input
! Inbuilt sensor supply ! Inbuilt sensor supply

(72 x 72) (48 x 96) (48 x 96) (72 x 72) (72 x 72)

RC2100 RC100 RC102C RC2106 RC2108


Description Rate indicator Rate indicator Rate indicator & totaliser Rate indicator Rate switch (with alarm)
(scalable input)
Display Seven segment LED; Seven segment LED; Seven segment LED; Seven segment LED; Seven segment LED;
Height: 0.5” Height: 0.5” Height: 0.5” Height: 0.5” Height: 0.5”
Count: 6 digits
Digits 4 digits 4 digits 4 digits 4 digits
Rate: 4 digits
Sensor Type PNP / NPN* PNP PNP / NPN PNP PNP

Voltage pulse (3 to 30V DC) Voltage pulse (3 to 30V DC) Voltage pulse (3 to 30V DC) Voltage pulse (3 to 30V DC) Voltage pulse (3 to 30V DC)
Input Type from Proximity switches, from Proximity switches, from Proximity switches, from Proximity switches, from Proximity switches,
Encoders, Solid state devices, Encoders, Solid state devices, Encoders, Solid state devices, Encoders, Solid state devices Encoders, Solid state devices,
Potential free contact Potential free contact Potential free contact Potential free contact
a) 0 to 30Hz
Input Speed 4 to 9999 pulses/min. 4 to 9999 pulses/min. Upto 3.5kHz Upto 3.5kHz
b) 0 to 2.5kHz
Setpoints 2 (Low alarm & High alarm)

Count: 9999.99, 99999.9


Range 4.00 to 9999 rpm 4.00 to 9999 rpm 999999 (user selectable) 4.00 to 9999 RPM 4.00 to 9999 RPM
Rate: 4.00 to 9999 RPM
RPS, RPM, RPH
Modes
(programmable)
Counting Direction Unidirectional (Up) Unidirectional (Up) Unidirectional (Up) Unidirectional (Up) Unidirectional (Up)
n n n
Scale Factor 0.00001 to 9.99999 x 10 0.001 to 9.999 x 10 0.001 to 9.999 x 10
n= -3, -2, -1, 0, 1, 2 n= -3, -2, -1, 0, 1, 2 n= -3, -2, -1, 0, 1, 2
Hysteresis 0 to 99 (LSD)

Power On Delay 0 to 999 sec

Alarm Delay 0 to 999 sec

Accuracy Rate: 0.05% Rate: 0.05% Rate: 0.05% (±2 counts) Rate: 0.05% (±1 count) Rate: 0.05% (±1 count)

Reset Front, Remote


Current count value: 1 year
Memory 10 years 10 years
Parameter setting: 10 years
Sensor Supply Inbuilt, 12V DC, ±10%, Inbuilt, 12V DC, ±10%, Inbuilt, 12V DC, 30mA Inbuilt, 12V DC, 30mA Inbuilt, 12V DC, 30mA
30mA 30mA
Low alarm status,
LED Indications
High alarm status
1 C/O (SPDT) each for
Output
high & low alarm
Relay Rating 5A @ 230V AC/ 24V DC

Supply voltage 85 to 270V AC/DC 85 to 270V AC/DC 85 to 270V AC/DC 85 to 270V AC/DC 85 to 270V AC/DC
AC: 50 or 60 Hz

Operating: 0 to 50°C Operating: 0 to 50°C Operating: 0 to 50°C Operating: 0 to 50°C Operating: 0 to 50°C
Temperature
Storage: -5 to 50°C Storage: -5 to 50°C Storage: 0 to 50°C Storage: -5 to 50°C Storage: -5 to 50°C
Humidity 95% RH 95% RH 95% RH 95% RH 95% RH
(non-condensing)

Weight 170 gms 180 gms 200 gms 170 gms 200 gms

Certifications

Dimensions Refer diagram C Refer diagram H(V) Refer diagram H(V) Refer diagram C Refer diagram C
on page 36 on page 36 on page 36 on page 36 on page 36
Terminal Connections

1 2 3 4 5 6
SENSOR
+12V CNT GND CNT +12V GND SELECTION
NPN PNP COM FILTER CONFIG
1 2 3 4 5 6 7 8 9 10 +12V RST
13 L 15 1 2 3 4 5 6 7 8 9 10
22 24
14 N 16 22 CNT 24
21 23
21 23
11 12 13 14 15 16 17 18 N L
11 12 13 14 15 16 17 18 N L
7 8 9 10 11 12 - + - +

* For NPN configuration


please contact factory

Ordering Code RC2100 RC100 RC102C RC2106 RC2108

29
Time Measuring
Instruments
selec
! 4 digit time interval meter
! Ideal for measuring:
MCB trip time ! Self powered
! 6 digit time totaliser ! Low cost
Relay changeover time ! Long battery life
! Selectable least count ! Self powered
! Least count upto 0.0001 sec ! Contact / AC input ! Long battery life
! Front / Remote reset ! Contact / AC input

36 x 72 48 x 96 48 x 96 24 x 48 48 x 48
TT412 ; TT12 TI103 LT920 LT945
Description Time Totaliser Time Interval meter Time Totaliser Time Totaliser

TT412 :7 segment LED;


Height: 0.3” 7 segment LED;
Display Liquid crystal display Liquid crystal display
TT12 : 7 segment LED; Height: 0.5”
Height: 0.5”
Digits 6 digits 4 digits 8 digits 8 digits

Modes Contact type, Stop watch, Pickup timer,


Drop off timer, Pick up/drop off timer
a) Autoranging: .0001 to 9999 sec a) 9999.59.59 hr:min:sec
Range 99999.9 / 999999 / sec / min / hr b) Fixed ranges: .9999, 9.999, 99.99, b) 999999.99 hr 999999.99 hrs
999.9,9999 sec
Direction Up Up Up Up

Input Mains, Potential free contact, Potential free contact, a) 24 to 260V AC a) Contact input
PNP sensor 3 to 30V DC from solid state devices b) Contact input b) 24 to 260V AC (factory set)
Accuracy 0.05% 0.05% 0.05% 0.05%
Front, Remote, Auto
Reset Remote (Reset time: 20 ms) Front, Remote No reset
(programmable)
Memory 10 years 5 years 5 years
Configuration Via rear terminals
Lock
Sensor Supply 12V DC (±10%) @ 30 mA 12V DC (±10%) @ 30 mA
(short circuit protected) (short circuit protected)
Supply voltage 85 to 270V AC/DC (AC: 50/60 Hz) 85 to 270V AC/DC (AC: 50/60 Hz) Battery powered Battery powered
Operating: 0 to 50°C Operating: 0 to 50°C Operating: 0 to 50°C Operating: 0 to 50°C
Temperature
Storage: -5 to 50°C Storage: -5 to 50°C Storage: -20 to 75°C Storage: -20 to 75°C
Humidity
(non-condensing) 95% RH 95% RH 95% RH 95% RH
TT412: 90 gms
Weight 190 gms 30 gms 50 gms
TT12: 190 gms
Certification

Dimensions TT412: Refer diagram F on page 36 Refer diagram H(V) on page 36 LT920 :Refer diagram N on page 36 Refer diagram M on page 36
TT12: Refer diagram H(V) on page 36
Terminal TT412
Voltage Input Voltage Input
Connections
STRT/ INP RST COM RNG EN INP
+12V HLD +12V RST COM CONFIG N L

1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8
1 2
NC/ NO/ COM +12V RST COM
C1 C2 24 - 260V AC
1 2 3 4 5 6 7 8 9 10 24 - 260V AC
22 24
21 23
STRT/ +12V RST COM CONFIG Contact Input Contact Input
HLD
11 12 13 14 15 16 17 18 N L
1 2 3 4 5 6 7 8 9 10 - + INP
INP RST COM RNG EN
22 COM 24
1 2 3 4 5 6 7 8 1 2
21 23
11 12 13 14 15 16 17 18 N L Contact Input

TT12
- +

Ordering Code TT412 TI103 LT 945- C : 48 x 48, contact input


TT12 LT 945- V : 48 x 48, Voltage input

30
Accessories
Adapter plates
To fit smaller products into 92 mm x 92 mm size, 69 mm x 69 mm or 48 mm x 48 mm size cutouts
Material: ABS

Model: AP9672 Model: AP9648 Model: AP7248 Model: AP6050 Model: AP4848
To fit 72 mm x 72 mm To fit 48 mm x 48 mm To fit 48 mm x 48 mm
product into 92 mm x product into 92 mm x product into 69 mm x
92 mm cutout 92 mm cutout 69 mm cutout

SNUBBER CIRCUIT TRANSPARENT FULL COVER


R - C network to reduce electrical noise Material: Polycarbonate
Model: APRC01 Size: To fit 48 mm x 48 mm products
Model: ACF4801

8 PIN SOCKET 48 x 48 COLLAR CLAMP


Mounting: a) DIN rail mounting b) Surface mounting Model: ACL4802
Model: AS08

31
Timing Diagrams for XTC5400 selec
TIMER MODE COUNTER MODE
1. ON delay 1. ON Delay ( OR mode )

Supply
Supply
Reset
Start

Preset
Reset
1 2
ch= ch=
Bat Bat 0

=1

=2
ch

ch
at

at
Output

B
T on T on T on Output

2. Interval 2. Interval ( OR mode )

Supply Supply

Reset
Start

Reset Preset
h=
1 =2
tc tch
Ba Ba
0
Output h=1 h=2
Batc Batc
T on
Output

3. Cyclic ON - First 3. Auto Reset ( NOR mode )

Set1
Supply
Set2
Start

Reset =1 =2
=1 =2 =3 tch tch
tch Ba Ba
tch tch Ba
Ba Ba
Rly1
Output Tstrt Ton Toff Ton Toff Tstrt Ton Toff Rly2
ARtime

4. Cyclic OFF - First 4. Time Pulse Reset ( NOR mode )

Supply Set1

Start
Set2
Reset
=1 =2 =3
tch tch tch
Ba Ba Ba 0
h =1 ch=2
Batc Bat

Output Tstrt Toff Ton Toff Ton Toff tstrt Rly1

Rly2
TPR time

5. Batch mode 5. Batch mode

Reset Reset

Preset Preset

0
0

Output
Output
Batch mode

32
Timing Diagrams for 800/642 Series selec
Function: ON Delay
! ON Delay: When input power is applied timing (t) begins, during which the output relay remains de-
Supply
energized . At the end of the preselected time (t), relay energizes. The output relay is de-energized Voltage
when power is removed, thus resetting the timer for the next cycle.
! Reset: Removing input voltage resets the time delay and output relay.
N/O Contact
NC Contact
t

t = set time delay


Function: Interval Delay
! Interval Delay: Applying the power supply starts the time delay & the output relay gets energized. At Supply
the end of the preset time, the contact gets de-energised. The timer is reset when the input power is Voltage
removed.
! Reset: Removing input voltage resets the time delay and output relay.
N/O Contact
NC Contact
t

t = set time delay

Function: Pulse Output


! Pulse Output: Applying the power supply starts the time delay, during which the output relay remains Supply
de-energized. At the end of the preset period, the relay gets energized for a preset time P(P=500ms). Voltage
At the end of time P again relay de-energizes.
! Reset: Removing input voltage resets the time delay, output relay and the sequence.
N/O Contact
NC Contact
t
P
t = set time delay
P = 500 msec

Function: Repeat Cycle Equal (OFF first)


! Repeat Cycle Equal (OFF First): Upon application of input voltage, the output relay remains de- Supply
energized and time t begins. At the end of the time t, output relay energizes for set time t. At the end of Voltage
time t again relay de-energizes and this cycle continues until input voltage is removed.
! Reset: Removing input voltage resets the time delay, output relay and the sequence.
N/O Contact
NC Contact
t t t

t = set time delay

Function: Repeat Cycle Equal (ON First)


! Repeat Cycle Equal (ON First): Upon application of input voltage, the output relay energizes and Supply
Time t begins. At the end of the time t, output relay de-energizes for set time t. At the end of time t again Voltage
relay energizes and this cycle continues until input voltage is removed.
! Reset: Removing input voltage resets the time delay, output relay and the sequence.
N/O Contact
NC Contact
t t t

t = set time delay

Function: Delay On Break


! Delay on Break: Input voltage must be applied before and during timing. Upon application of input Supply Voltage
voltage, the output remains de-energized. On closing the control contact 'Y' the output energizes. The (A1/A2)
time delay begins when 'Y' is opened. The output remains energized during timing. At the end of the Control Contact
time delay the output de-energizes. The output will energize if 'Y' is closed when input voltage is Y (A1/26)
applied.
! Reset: Re-closing the 'Y' contact during timing resets the time delay. Removing input voltage resets NO Contact
the Time delay and output. NC Contact
t t

t = set time delay

Function: Delay on Make with Totalise(Time Storage):


! Delay on Make with Totalize (Time Storage): Input voltage must be applied before and during Supply Voltage
timing. The output is de-energized before and during the time delay. Each time the 'Y' contact is (A1/A2)
closed, the time delay progresses; when it opens, timing stops. When the amount of time 'Y' is closed
equals the full time delay, the output energizes and remains energized until reset. Control Contact
Y (A1/26)
! Reset: Removing input voltage resets the time delay and output.
NO Contact
NC Contact
t1 t2

t1+t2=set time delay

33
selec
Function: Delay on Make / Delay on Break
! Delay on Make / Delay on Break: Delay on Make time delay t1 and delay on break time delay t2 are Supply Voltage
same i.e. Upon application of input voltage and the closure of 'Y', t1 begins and the output remains de- (A1/A2)
energized. At the end of t1, the output energizes. Upon the opening of 'Y' t2 begins. At the end of t2, Control Contact
the output de-energizes. Y (A1/26)
! Reset: If 'Y' is opened during t1, then t1 is reset and the output remains de-energized. And if 'Y' is
closed during t2 then t2 is reset and the output remains energized. Removing input voltage resets the NO Contact
time delay and output NC Contact
t1 t2
t1 = t2 = t
t = Set time delay
Function: Interval after Break
! Interval after Break: Input voltage must be applied before and during timing. Upon application of Supply Voltage
input voltage, the output remains de-energized. On opening (after a closure), the control contact 'Y' (A1/A2)
the output energizes and time delay begins. The output remains energized during timing. At the end of Control Contact
the time delay the output de-energizes. Y (A1/26)
! Reset: Opening (by closing and then opening) the 'Y' contact during timing resets the time delay.
Removing input voltage resets the Time delay and output. NO Contact
NC Contact
t t

t = Set time delay

Function: Interval with Totalise (Time Storage):


! Interval with Totalize (Time Storage): Input voltage must be applied before and during timing. The
Supply Voltage
output is energized before and during the time delay. Each time the 'Y' contact is closed, the time delay
(A1/A2)
progresses; when it opens, timing stops. When the amount of time 'Y' is closed equals the full time
delay, the output de-energizes and remains de-energized until reset. Control Contact
Y (A1/26)
! Reset: Removing input voltage resets the time delay and output.
NO Contact
NC Contact
t1 t2
t1 = t2 = Set time delay

Function: Interval on make / Interval on break

! Interval on Make / Interval on Break: Interval on Make time delay t1 and Interval on break time delay Supply Voltage
t2 are same i.e. t. Upon application of input voltage and the closure of 'Y', t1 begins and the output (A1/A2)
energizes. At the end of t1, the output de-energizes. Upon the opening of 'Y' t2 begins and the output Control Contact
energizes again. At the end of t2, the output de-energizes. Y (A1/26)
! Reset: If 'Y' is opened during t1, then t1 is reset and the output remains energized. And if 'Y' is closed
during t2 then t2 is reset and the output remains energized. Removing input voltage resets the time NO Contact
delay and output NC Contact
t1 t2

t = Set time delay

Function: Single Shot


! Single Shot: Input voltage must be applied before and during timing. Upon momentary or maintained Supply Voltage
closure of the control contact 'Y' the output energizes and the time delay begins. At the end of the delay (A1/A2)
the output de-energizes. Opening or re-closing the 'Y' contact during timing has no effect on the time Control Contact
delay. Y (A1/26)
! Reset: Reset occurs when the time delay is complete and the 'Y' contact is open. Removing input
voltage resets the time delay and output. NO Contact
NC Contact
t t

t = Set time delay

Function: Retriggerable Single Shot


! Retriggerable Single Shot: Input voltage must be applied before and during timing. Upon Supply Voltage
momentary or maintained closure of the control contact 'Y' the output energizes and the time delay (A1/A2)
begins. At the end of the delay the output de-energizes. Control Contact
! Reset: Re-closing 'Y' contact resets the time delay and restarts timing. Removing input voltage resets Y (A1/26)
the time delay and output.
NO Contact
NC Contact
ta t
t = Set time delay
ta< t

Function: Latching Relay


! Latching Relay: By closing control contact "Y"of the relay will change it's state and maintain it until
Supply Voltage
power to unit is removed or interrupted. (A1/A2)
Control Contact
Y (A1/26)

NO Contact
NC Contact

34
Timing Diagrams for Digital Timers selec
Applicable for XT543 / XI546 / X1246 / X1346
Function : ON delay Function : Cyclic Function : ON delay-pulse Function : Interval delay
(ON time first) start
Supply
Supply Supply voltage Supply
Voltage
t Voltage t
Voltage t1 t2 Start Contact
NO NO t NO
Contact NO Contact Contact
Contact
t = Set delay time t1= ON time, t2 = OFF time t = Set delay time t = Set delay time
Function : Reset Function : Cyclic Function: Gate start-ON delay
Supply Voltage (OFF time first) Supply voltage
Supply
Voltage
Reset Contact t2 t1 Gate Contact
t t1 th t2
NO Contact NO NO Contact
Contact
t = Delay time reset t1= ON time, t2 = OFF time t=delay time = t1+ t2, th = hold time

Applicable for XT5042 only


1. ON delay, Interval modes: 2. Cyclic ON first, Cyclic OFF first modes: 3. Instantaneous + Delayed at start pulse:

Supply Supply Supply

Start Start Start

Reset Reset Reset

Output Output
Instant
ON Delay Cyclic ON Tstrt TON TOFF TON TOFF Tstrt TON TOFF
T strt T ON T strt T ON T strt T ON contact

Output Output Delayed


Interval T strt T ON T strt T ON T strt T ON Cyclic OFF Tstrt TOFF TON TOFF TON tstrt TOFF TON contact Tstrt TON Tstrt TON

4. Instantaneous + Delayed at power ON: 5. Motor reverse mode: 6. Batch mode

Supply
Supply
Start
Batch
Reset reset
Reset
Preset
Relay 1
t1 0
Instant
contact t2 t2
Output
Relay2
Delayed t3
contact Tstrt TON Tstrt TON t1 = ON time of relay1, t3 = ON time of relay2,
t 2 = Pause time

Functions in PT380 only


Serial Serial (with cascading ) Parallel
Start Signal Start Signal Start Signal

channel-1
ch-1 ch-1
Timer 1
ch-2 ch-n channel-2
Cycle1 ch-n
Timer 2 ch-1
ch-1 ch-n channel- n
ch-2
Cycle N ch-n
n = 8 / 16; N = 0000 to 9999 or continuous

642VTR
THREE PHASE MODEL
Supply R Phase

Supply Y Phase

Supply B Phase

NO contact
NC contact
td = ON delay time
td tr td tr td tr td tr = reset time
Un = 75% of supply
voltage

35
Dimensions selec
Terminal type Plug type Panel cutout
48 45 46
Diagram 48 45 46
Diagram
A B
7 70.5 79
48 100 46
46 10
Front bezel Side view Panel Cutout

72 68 69 92
Diagram Diagram 96 90

C D
72 115 69 96 95 92
10 Front bezel 25 Side view Panel Cutout
Front bezel Side view Panel Cutout

Diagram F Diagram G
Panel Cutout

A D F

33 28 29

B C G
75 74.5 71 E
3.5
Models
DIM A B C D E F G
X 96 96 110 90 10 92 92
Y 97 97 88 90 10 92 92
Z 96 96 70 90 10 92 92

Diagram H Diagram H(W)


Panel Cutout
Panel Cutout

A D F A D F

B C G G
E B C
E
Models
DIM A B C D E F G
U 52 102 50 44.8 4.5 46 92 Models
DIM A B C D E F G
V 50 97.5 88 45 10 46 92 W 97.5 50 88 91 10 92 46

Diagram - K Diagram - L

Front View Side View Panel Cutout Front View Side View Panel Cutout
60
38.5
(+0.0/+0.5)

Diagram Diagram
22.5
46
44.80

50

M N 45.5
(+0.0/+0.5)
46
Dia 50
44.80 4

Diagram O
32 28
Panel Cutout
148

134

140

250 60
5 242

36
Dimensions selec
45mm 45mm

Diagram Diagram

68mm
73mm

68mm
73mm
P(I) P(II)

90mm 52.5mm 90mm 52.5mm

Panel Cutout Panel Cutout

A E F A E F
Diagram Diagram
Q(I) B D G
Q(II) B D G
C C
A B C D E F G
10
A B C D E F G
96 96 60 90 92 92
99 99 5 46 91 92 92

Panel Cutout Diagram S

A E F
Diagram
Q(III) B D G
C

A B C D E F G
99 99 5 50 90.5 91.5 91.5

Diagram V Front Side


44mm
52 45 46
Diagram
T
52 94 46
4
67.5mm
45mm

35.3mm
Front bezel Side view Panel Cutout 90mm

Diagram U

Front bezel Side view Panel Cutout 17.5


mm 60mm
Symmetrical 35mm Din Rail (EN50022) Mouting

MODELS
DIM A B C D E F G Table R Height Width Depth
TC/XT 5XX 52 52 94 45 4 46 46 Zone 1 185.0 95.0 250.0
TC/XT 2XX 72 72 83.7 67 4.5 69 69 Zone 2 200.0 145.0 250.0
TC/XT 3XX 96 96 73 90.5 5 92 92 Zone 4 210.0 300.0 290.0
Zone 6 220.0 385.0 290.0
Zone 8 210.0 590.0 290.0
Zone 12 220.0 690.0 290.0

Diagram A Front bezel Side view EF Panel Cutout

W
B D G
C

A B C D E F G
76 76 3.5 50 67.5 67.5 67.5

0910/A014/REV6

37
Selec Controls Pvt. Ltd.
(An ISO 9001:2008 Company)

Regd. Office Factory


E-121, Ansa Industrial Estate, EL-27/1, Electronic Zone,
Saki Vihar Road, Andheri (E) TTC Industrial Area, MIDC,
Mumbai 400 072 Mahape, Navi Mumbai - 400 710
INDIA INDIA
Tollfree: 1800 22 7353 (BSNL/MTNL only) Tel: 91-22-4141 8482
Tel.: +91-22-4039 4200 / 4202 Fax: 91-22-2762 1385
Fax: +91-22-2847 1733 Email: mahape@selec.com
Web: www.selec.com
Email: sales@selec.com

You might also like