0% found this document useful (0 votes)
35 views2 pages

Brosur SM-KS3

This document provides the technical specifications for several models of UPS systems ranging in capacity from 80kVA to 1000kVA. The specifications include input and output voltage ranges, rated current, frequency, efficiency, dimensions, weight, and other key parameters. All models operate at 50Hz frequency, have an efficiency of 98% or greater, and provide overvoltage and undervoltage protection with a delay time of 4-7 seconds.

Uploaded by

Tio 27
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
35 views2 pages

Brosur SM-KS3

This document provides the technical specifications for several models of UPS systems ranging in capacity from 80kVA to 1000kVA. The specifications include input and output voltage ranges, rated current, frequency, efficiency, dimensions, weight, and other key parameters. All models operate at 50Hz frequency, have an efficiency of 98% or greater, and provide overvoltage and undervoltage protection with a delay time of 4-7 seconds.

Uploaded by

Tio 27
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Technical Specification

SPECIFICATION
ITEM Unit Remarks
SM80KS3 SM100KS3 SM120KS3 SM150KS3 SM200KS3 SM250KS3
Capacity kVA 80 100 120 150 200 250
Input Voltage V 304 ~ 456 3P + N
Output Voltage V 380 ± 1% 3P + N
Rated Current A 120 150 180 225 300 375
Frequency Hz 50
Delay Time S 4 ~ 7 (Over-voltage and Under-voltage protection)
Efficiency % ≥ 98
Ambient Temperature °C -20 ~ +45
Ambient Humidity % < 90 Relative Humidity
Control System Central control module based on DSP
Electrical Strength No flashover or breakdown when at 2500V/min
Insulation Resistance Ω ≥ 5M
Ingress Protection IP21
Insulation and
Class H, VPI process
Thermal Endurance
Display HMI / LCD display of all electrical parameters
850x320x 1010x405x
Dimension Unit mm 710x285x1325 900x400xx1600 DxWxH
1470 1750
930x405x 1100x500x
Dimension Packing mm 790x370x1480 980x485x1750 DxWxH
1625 1895
Weight kg 228 240 295 325 387 499 Gross

SPECIFICATION
ITEM Unit Remarks
SM300KS3 SM400KS3 SM500KS3 SM600KS3 SM800KS3 SM1000KS3
Capacity kVA 300 400 500 600 800 1000
Input Voltage V 304 ~ 456 3P + N
Output Voltage V 380 ± 1% 3P + N
Rated Current A 450 600 750 900 1200 1500
Frequency Hz 50
Delay Time S 4 ~ 7 (Over-voltage and Under-voltage protection)
Efficiency % ≥ 98
Ambient Temperature °C -20 ~ +45
Ambient Humidity % < 90 Relative Humidity
Control System Central control module based on DSP
Electrical Strength No flashover or breakdown when at 2500V/min
Insulation Resistance Ω ≥ 5M
Ingress Protection IP21
Insulation and
Class H, VPI process
Thermal Endurance
Display HMI / LCD display of all electrical parameters
Dimension Unit mm 1160x505x1900 1300x600x2090 1800x800x1900 DxWxH
Dimension Packing mm 1260x590x2080 1390x690x2250 1890x890x2080 DxWxH
Weight kg 608 750 1170 1300 1844 2190 Gross
Specifications are subject to change without prior notice.