Timer Drain
Timer Drain
A ir ge
y r
ooler Dr ischa
f t er C D
A
rator ilte
r
epa erf
S Aft
ra in
D
4
T o
TDV
4 er
a l ves Dry
Rec
eiver
Timer Drain Valves
Tim
er D
Automatic
ra in V
rai
n in Air Compressor and Air Drying Applications n
Draining of Condensate
D rai
o T D
TDV TDV To
ra in e
ToD a l ves Int
ak
TDV V Air
D r ain
e r
Pre
fi lter Tim
or
ess
Co mpr
r y A
r
oole D isc
er C D
Aft
rator ilte
r
epa erf
S Aft
ra in
T oD
TDV
s er
Dry
iver V alve
Rec
e
D r ain
e r in
Tim oD
ra ra in
TDV
T
TDV ToD
in
Dra s
4
General Description
The ASCO® Timer Drain Valves are designed for automatic draining of condensate This product line combines a solid state electronic timer together
created in Air Compressor and Air Drying applications. This eliminates the need for with a proven reliable ASCO Red-Hat II® solenoid valve. By choosing from a large
manual draining, and protects systems from flooding. Some locations where this variety of valve sizes and adjusting the on-off ranges on the timer, the user is
product can be installed are compressor discharge lines, separators, receiver tanks, able to customize for their exact drainage requirements.
filters, drip legs, dryers and other compressed air equipment.
% )
■ CSA approved
■ CE certified
Separator
Receiver TDV
To Drain
Prefilter TDV
TDV
To Drain
To Drain
Timer Drain Valves
Cv = .35 Cv = .5 Cv = 3 Cv = 5
2 3 4 5 6 7 8 2 3 4 5 6 7 8 2 3 4 5 6 7 8 2 3 4 5 6 7 8
50 0.08 0.12 0.16 0.21 0.25 0.29 0.33 0.12 0.18 0.24 0.30 0.35 0.41 0.47 0.70 1.06 1.40 1.77 2.10 2.47 2.82 1.78 1.77 2.36 2.95 3.53 4.12 4.71
100 0.12 0.17 0.23 0.29 0.35 0.41 0.46 0.17 0.25 0.33 0.42 0.50 0.58 .067 1.00 1.50 2.00 2.50 3.00 3.50 4.00 1.67 2.40 3.33 4.17 5.00 5.83 6.67
150 0.14 0.21 0.29 0.36 0.43 0.50 0.57 0.20 0.31 0.41 0.51 0.61 0.71 0.82 1.22 1.83 2.44 3.05 3.66 4.27 4.88 2.04 3.06 4.08 5.10 6.12 7.14 8.16
200 0.17 0.25 0.33 0.41 0.50 0.58 0.66 0.24 0.35 0.47 0.59 0.71 0.82 0.94 1.42 2.13 2.84 3.55 4.26 4.97 5.68 2.36 3.54 4.72 5.90 7.08 8.26 9.44
300 0.20 0.30 0.40 0.51 0.61 0.71 0.81 0.29 0.43 0.58 0.72 0.86 100 1.15 1.74 2.61 3.48 4.35 5.22 6.09 6.96 2.88 4.32 5.76 7.20 8.64 10.08 11.52
* For volume discharge information of longer on-times, please contact local ASCO office.
4
Supply Voltage: 24 – 240V AC/DC
50/60 Hz
Current Consumption: 4 mA max
Operating Temperature: 14˚F – 122˚F
Environmental Protection: NEMA 4 4
1/4" NPT
‡
6' Power cord has DIN connector and 3-prong plug for wall outlet.
1 1 13 5 150 150 100 125 125 125 18 0 15 0 SC8210G4 12D 6.1/F 11.6/F