1104C-44G/TG/TAG Electric Power Engines
Power range 1500 rpm 40-103 kW (engine gross power)
Power range 1800 rpm 45-118 kW (engine gross power)
Emissions EU Stage II/U.S. EPA Tier 2
Building upon Perkins proven reputation within the power
generation industry, the 1104C Series range of ElectropaK
engines now fit even closer to customers’ needs.
In the world of power generation today, success is only
gained by providing more for less. Therefore with the 1104C
products, Perkins has engineered for its customers even
higher levels of reliability, yet lowered the cost of ownership.
Crucially, bare engine noise is lower than ever before. Rapid
starting and pick-up are naturally built in especially for cold
operation, but where legislation or local markets demand an
emissions capability, the engine is designed to comply with
the required regulations including EU Stage II mobile off-
highway legislation and TA Luft (1986) regulations.
Features and benefits
l The Perkins® 1104C Series was developed l Service intervals are set at 500 hours as standard
following an intensive period of customer research. assuming approved fuels and lubricating oils are
The cylinder blocks ensure bore roundness is used to deliver low operating costs.
maintained under the pressures of operation, l Throughout the entire life of a Perkins engine, we
as well as significantly reducing mechanical provide access to genuine factory specification
and combustion noise. A cross-flow cylinder parts giving reassurance that you receive excellent
head design optimises combustion control, and quality for the lowest possible cost, wherever
combines with turbocharger and chargecooler your Perkins powered machine is operating in the
technology to achieve the best combination of world.
power delivery and low exhaust emissions.
l Through an experienced global network of
l The refined structure of the 1104C range leads distributors and dealers, fully trained engine
to an exceptionally low noise signature coupled experts deliver total service support around
with the compact packaging provides ease of the clock, 365 days a year. They have a
integration. comprehensive suite of web based tools at their
l To meet environmental needs swirl conditioned air finger tips, covering technical information, parts
is delivered through the new cross-flow cylinder identification and ordering systems, all dedicated
head, and burns cleanly with the high pressure to maximising the productivity of your engine.
fuel from an advanced technology rotary pump
delivering high quality as standard. Perkins actively pursues product support
excellence with our distribution network investing
in their territory to provide you with a consistent
quality of support across the globe.
All information in this document is substantially correct at time of printing and may be altered subsequently.
Photographs are for illustrative purposes only and may not reflect final specification.
Final weight and dimensions will depend on completed specification.
Information subject to selected configuration, and subject to change without notice.
Engine power measured per ISO 14396:2002
PN3247/03/21 Produced in England ©2021 Perkins Engines Company Limited
1104C-44G/TG/TAG Electric Power Engines
Power range 1500 rpm 40-103 kW (engine gross power)
Power range 1800 rpm 45-118 kW (engine gross power)
Emissions EU Stage II/U.S. EPA Tier 2
Specification
1104C-44
G1 G2 TG1 TG2 TG3 TAG1 TAG2
Configuration ElectropaK
Cylinders 4 vertical in-line
Displacement, litres (in ) 3
4.41 (269)
Turbocharged,
Aspiration Natuarally aspirated Turbocharged
air-to-air chargecooled
Bore and stroke, mm (in) 105 x 127 (4.1 x 5.0)
Combustion system Direct injection
Compression ratio 19.3:1 18.2:1
Exhaust aftertreatment N/A
Rotation (viewed from flywheel) Anti-clockwise, viewed on flywheel
Total lubricating oil capacity, litres (US gal) 7 (2) 8.0 (2.1)
Cooling system Watercooled
Total coolant capacity, litres (US gal) 12.8 (3.4) 12.6 (3.3)
Standard equipment
1104C-44
G1 G2 TG1 TG2 TG3 TAG1 TAG2
Electro unit or ElectropaK ElectropaK
Radiator fitted ü
Fuel filter, engine mounted ü
Water separator N/A
Fuel priming pump (manual/electric) Manual
Fuel cooler (not required for most
N/A
installations)
Air filter, engine mounted ü
Engine ECM, engine mounted N/A
Wiring harness to ECM N/A
Wiring harness (all connectors to single
N/A
customer interface)
Starter motor ü
Battery charging alternator ü
Flywheel housing ü
Flywheel ü
Fan ü
Fan guard ü
Temperature and oil pressure for
ü
automatic stop/alarm configurable
All information in this document is substantially correct at time of printing and may be altered subsequently.
Photographs are for illustrative purposes only and may not reflect final specification.
Final weight and dimensions will depend on completed specification.
Information subject to selected configuration, and subject to change without notice.
Engine power measured per ISO 14396:2002
PN3247/03/21 Produced in England ©2021 Perkins Engines Company Limited
1104C-44G/TG/TAG Electric Power Engines
Power range 1500 rpm 40-103 kW (engine gross power)
Power range 1800 rpm 45-118 kW (engine gross power)
Emissions EU Stage II/U.S. EPA Tier 2
Technical information
Engine Power Typical Prime Fuel Consumption
Speed Type of Generator
Model Gross Net Output* (Net) 110% 100% 75% 50%
Operation
rpm kW (hp) kW (hp) kVA kWe g/kWh g/kWh g/kWh g/kWh
Prime 40 (54) 39 (52) 44 35
1500 not available
Standby 44 (58) 43 (58) 48 39
1104C-44G1
Prime 45 (60) 43 (58) 49 39
1800 228 226 235 250
Standby 49 (66) 48 (64) 43 54
Prime 49 (66) 47 (63) 53 43
1104C-44G2 1800 235 232 233 250
Standby 54 (72) 52 (70) 59 47
Prime 64 (86) 60 (80) 68 54
1104C-44TG1 1800 232 230 233 245
Standby 71 (95) 67 (90) 75 60
Prime 56 (75) 54 (72) 60 48
1104C-44TG2 1500 229 226 226 227
Standby 62 (83) 59 (79) 67 53
Prime 56 (75) 54 (72) 60 48
1104C-44TG3 1500 223 219 220 225
Standby 62 (83) 59 (79) 67 53
Prime 75 (101) 72 (96) 80 64
1500 210 211 216 222
Standby 83 (111) 79 (106) 89 71
1104C-44TAG1
Prime 86 (115) 80 (108) 91 72
1800 218 223 229 237
Standby 94 (126) 89 (119) 100 80
Prime 94 (126) 90 (121) 101 81
1500 205 205 207 204
Standby 103 (138) 100 (133) 112 90
1104C-44TAG2
Prime 107 (143) 102 (136) 114 92
1800 214 218 218 228
Standby 118 (157) 112 (151) 127 101
*Generator powers are typical and based on typical alternator efficiencies and a
power factor (cos θ) or 0.8.
Engine package weights and dimensions
1104C-44
G1 G2 TG1 TG2 TG3 TAG1 TAG2
Configuration ElectropaK
951 x 1162 x 622 951 x 1239 x 615 966 x 1259 x 721
Dimensions, H x L x W, mm (in)
(37.4 x 45.7 x 24.5) (37.4 x 48.8 x 24.2) (38 x 49.6 x 28.4)
Dry weight, kg (lb) 386 (851) 401 (884)
Prime power: Power available at variable load in lieu of a main power network. Overload of 10% is permitted for 1 hour in every 12
hours of operation.
Standby (maximum): Power available at variable load in the event of a main power network failure. No overload is permitted.
All information in this document is substantially correct at time of printing and may be altered subsequently.
Photographs are for illustrative purposes only and may not reflect final specification.
Final weight and dimensions will depend on completed specification.
Information subject to selected configuration, and subject to change without notice.
Engine power measured per ISO 14396:2002
PN3247/03/21 Produced in England ©2021 Perkins Engines Company Limited