A-Star Testing & Inspection (S) Pte Ltd
No 5, Soon Lee Street #03-37 | Pioneer Point
Singapore 627607 |Tel: +65 62616162 / +65 62616169
Email: enquiry@astartesting.com.sg | www.astargroup.com
MAGNETIC PARTICLE TESTING REPORT
Owner : NA Report No. : ATI/TRELLEBORG/BAROSSA FPSO/MT/S-064
Client : TRELLEBORG SINGAPORE PTE LTD Request No. : NA
Address : 4 JALAN PESAWAT,SINGAPORE,619362 Tested Date : 14-Mar-2023
WON No : NA PO Number : NA
Project : BAROSSA FPSO Specification : DNVGL-CG-0051 ( Ed: 2015 )
Site / Location : TRELLEBORG WORKSHOP Procedure No / Revision : ATI/QCP/MT/61; REV:06A
Description : TYPE 1B TOP STRUCTURE / 1B-T-3 Acceptance Criteria : Level 2X of ISO 23278 (Ed : 2015)
Surface Condition : AS WELDED & CLEANED Material Specification : CARBON STEEL
Stage of Examination : AFTER 48 HOUR'S OF WELDING Surface Temperature : Ambient
PURPOSE AND TECHNIQUE
Purpose of Examination : To Detect Surface & Near Surface Discontinuity
Evaluation of Indication : Discontinuity on the surface will be indicated by the retention of magnetic particles
Test Method : Continuous Wet Method (Visible)
Magnetization Technique : Yoke Type (Longitudinal Magnetization)
Lighting Equipment : Artificial Lighting Using Head lamp / Torch Light (If Applicable)
EQUIPMENT AND CALIBRATION
Equipment Model : MAGNAFLUX / Y-1 220 V A/C Testing Medium : NABAKEM (220221/6)
Equipment Sl. No. : 1036 Contrast Medium : NABAKEM (220503/1A)
Lifting Block Sl.No. : 202278 Application Method : SPRAYING
Lifting Capacity : 10 Lbs. (4.5 kgs) Pole Spacing : 3" to 6"
Lighting Illumination Level : 1750 LUX
Field Indicator : CASTROL STRIP
Light Meter Sr.No : C220778645
RESULT OF EXAMINATION
Scope of Examination : 100% Magnetic particle testing was carried out on welded joints
(Please refer to the attached data sheet and drawings for test details)
Interpretaion : No Relevant indication were detected at the time of Inspection
Item Tested comply with the above Code and Acceptance criteria
Result of Examination : Acceptable
MARUTHAI VEERAN PANDIYAN SACHIN SAJEEV
NDT INSPECTOR Approved Signatory Reviewed/Witnessed by: Reviewed/Witnessed by: Reviewed/Witnessed by:
PCN LEVEL 2 (PCN NO:328018) NDT LEVEL III Date: Date: Date:
Date: 15-Mar-2023 Date: 15-Mar-2023
This report shall not be reproduced except in full, without the written approval of A-Star Testing & Inspection (S) Pte Ltd
Form No : ATI-FORM-MT-02, Rev 00 Page No: 1 of 4
No 5, Soon Lee Street | Pioneer Point #03-37 | Singapore 627607 | Tel +65 62616162 | Email:Enquiry@astartesting.com.sg
MAGNETIC PARTICLE TESTING REPORT
CLIENT: TRELLEBORG SINGAPORE PTE LTD REPORT NO: ATI/TRELLEBORG/BAROSSA FPSO/MT/S-064
WELDING
S/NO MARK NO. Qty Joint No Size SCH / THK WELDER NO. TYPE OF WELD RESULT REMARKS
PROCESS
4477-TRB-N-XS-00002.001 REV-A (SHT 02
OF 17)/ STIFFENER A & B - TOP PLATE /
1 3 PLACES 1B-WJ-1 - 65mm TS-L11 FCAW - ACCEPTABLE
WPS NO: TS-WPS-11+14 / TAG NO: TP-3 &
STI-A-3 & STI-B-5, 6
4477-TRB-N-XS-00002.001 REV-A (SHT 02
OF 17)/ STIFFENER A - STIFFENER B / WPS
2 2 PLACES 1B-WJ-2 - 65mm TS-L11 FCAW - ACCEPTABLE
NO: TS-WPS-11+14 / TAG NO: STI-A-3 &
STI-B-5, 6
4477-TRB-N-XS-00002.001 REV-A (SHT 02
OF 17)/ STIFFENER A & B - SIDE PLATE /
3 4 PLACES 1B-WJ-3 - 65mm TS-L11 FCAW - ACCEPTABLE
WPS NO: TS-WPS-11+14 / TAG NO: STI-A-3
& STI-B-5, 6 & SP-9, 10, 11, 12
4477-TRB-N-XS-00002.001
REV-A (SHT 02 OF 17) /
4 SIDE PLATE & TOP PLATE / 4 PLACES 1B-WJ-4 - 65mm TS-L11 FCAW - ACCEPTABLE
WPS NO: TS-WPS-11+14 /
TAG NO: SP-9, 10, 11, 12 & TP-3
4477-TRB-N-XS-00002.001 REV-A (SHT 02
OF 17)/ STIFFENER A & B - BASE PLATE /
5 3 PLACES 1B-WJ-5 - 65mm TS-C02 FCAW - ACCEPTABLE
WPS NO: TS-WPS-11+14 / TAG NO: STI-A-3
& STI-B-5, 6 & BP-3
4477-TRB-N-XS-00002.001
REV-A (SHT 02 OF 17) /
6 BASE PLATE & SIDE PLATE / 4 PLACES 1B-WJ-6 - 65mm TS-C02 FCAW - ACCEPTABLE
WPS NO: TS-WPS-11+14 /
TAG NO: SP-9, 10, 11, 12 & BP-3
4477-TRB-N-XS-00002.001 REV-A (SHT 02
OF 17)/ SIDE STIFFENER PLATE SIDE PLATE
7 4 PLACES 1B-WJ-7 - 65mm TS-C02 FCAW - ACCEPTABLE
/ WPS NO: TS-WPS-11+14 / TAG NO: SSTIP-
9, 10, 11, 12 & SP-9, 10, 11, 12
4477-TRB-N-XS-00002.001 REV-A (SHT 02
OF 17)/ SIDE STIFFENER PLATE TOP PLATE
8 4 PLACES 1B-WJ-8 - 65mm TS-C02 FCAW - ACCEPTABLE
/ WPS NO: TS-WPS-11+14 / TAG NO: SSTIP-
9, 10, 11, 12 & TP-3
This report shall not be reproduced except in full, without the written approval of A-Star Testing & Inspection (S) Pte Ltd
Form No: ATI-FORM-MT-02, Rev 00 Page No: 2 of 4
No 5, Soon Lee Street | Pioneer Point #03-37 | Singapore 627607 | Tel +65 62616162 | Email:Enquiry@astartesting.com.sg
Report No: ATI/TRELLEBORG/BAROSSA FPSO/MT/S-064 Page No: 3 of 4
Report No: ATI/TRELLEBORG/BAROSSA FPSO/MT/S-064 Page No: 4 of 4