SR06AM
Conforms to EN60204-1, EN954-1, EN292,
EN50081, and EN50082
UL listed, CSA and BG approved
SR06AM
Dual-Channel Universal Monitoring Safety Relay
■ Power requirements—the ■ Contactor monitoring is pro-
SR06AM will accept 24VACDC, vided with a N/C loop between
safety monitoring relays
110VAC, or 220VAC X1 and X2 on the SR06AM
■ Selectable Inputs—Dual or ■ Selectable reset modes—
single N/C input channels are Manual or automatic reset
switch selectable mode is switch selectable on
the SR06AM
■ Outputs—the SR06AM has
3 N/O outputs to route power to
the coils of power contactors
plus 1 N/C auxiliary output for
signaling purposes
Go to the Engineering Guide
E in this catalog for in-depth information on
safety standards and use of this product.
Scientific Technologies Inc. STI Scientific Technologies GmbH
Fremont, CA R
Freiburg, Germany
Tel. 1/510/608-3400 1/888/510-4357 F8 Tel. +49-761-455 26 0
SR06AM
■ Operation
Without a Safety Monitoring Relay Output Contact Arrangements
Contractor,
Possible
FAULT
Wiring,
Possible FAULT
Switch,
Possible FAULT
With a Safety Monitoring Relay SR06AM Internal Switch
A1 S13 S24 X1 41 13 23 33
SEE SIDE FOR SUPPLY
POWER
OUTPUT
SRO6AM K1
Universal
K2
Safety Relay
EN 60204 SINGLE
BS 2771 CHANNEL
Guardmaster Ltd ISOLATE BEFORE
Wigan, England REMOVING COVER
A2 S14 S23 X2 42 14 24 34
R & T internal selector switch
R = Monitored manual reset facility with
Switch circuit SR06AM Contactors
system check for high integrity using a
SR06AM monitors for monitors itself for monitoring
momentary push button. The push and release
any single fault that any internal fault provided if two or
feature means the button cannot be held in.
may cause a danger more contactors
are used in series T = Automatic system check
safety monitoring relays
The safety function is ensured by the safety monitoring relay.
Terminal Connections
SUPPLY INPUT INPUT OUTPUT SAFETY SAFETY SAFETY AUXILIARY
CIRCUIT 1 CIRCUIT 2 MONITORING OUTPUT 1 OUTPUT 2 OUTPUT 3 SIGNALLING
(N/C) (N/C) & RESET (N/O) (N/O) (N/O) (N/C)
A1 A2 S13 S14 S23 S24 X1 X2 13 14 23 24 33 34 41 42
For the Latest Information
Try Our Fax Back System at 1/916/431-6544
On the Internet: www.sti.com E-mail: sales@sti.com
Scientific Technologies Inc. STI Scientific Technologies GmbH
Fremont, CA R
Freiburg, Germany
Tel. 1/510/608-3400 1/888/510-4357 F9 Tel. +49-761-455 26 0
SR06AM
■ Circuit Example
Switching Switching
Circuit 1 Circuit 2
Key
Contactor monitoring circuit
Contactor switching circuit
SR06AM Switching Circuit
Reset
Contactor
Switches up to 3 contactors
A1 A2 X1 X2 S23 S24 13 23 33 41
F1
SW1
RL1
~ RL1
R3
RL5
RL3 RL2 RL3
=
RL4
RL1
RL4
RL2
RL3
RL4 SW2
RL4
RL3
RL2 RL3 RL5 RL4
safety monitoring relays
S13 S14 14 24 34 42
■ Dimensions—in/mm
SR06AM
4.72 1.79
120 45.5
2.87
73
1.38
DIN RAIL MOUNTING
35
Go to the Engineering Guide
E in this catalog for in-depth information on
safety standards and use of this product.
Scientific Technologies Inc. STI Scientific Technologies GmbH
Fremont, CA R
Freiburg, Germany
Tel. 1/510/608-3400 1/888/510-4357 F10 Tel. +49-761-455 26 0
SR06AM
■ Specifications
Electrical All Models SR06AM24 SR06AM110 SR06AM220
Power Supply: 24 VAC/DC 110 VAC 220 VAC
Power Consumption: <4 VA
Internal Fuse: 500 mA slow-acting fuse
Safety Inputs: 2 N/C Dual or Single channel selectable
Relay Outputs: 3 N/O + 1 N/C Auxiliary
Max Switched AC: 4A/250 VAC
Max Switched DC: 2A/30 VDC
Min Switched Current/Voltage: 10 mA/10V
Impulse withstand Voltage: 2500V
Max Drop-out Time: 90 m/sec
Max Output Fuse: 5A Quick-acting fuse
Reset Mode: Manual or Automatic selectable (Time to reset is 35-50 m/sec.)
Contactor Monitoring: N/C Loop between X1 and X2
Mechanical
Mounting: 1.38 in (35 mm) DIN rail
Case Material: Polycarbonate
Max wire size: 1 x 12 AWG (2.5 mm) stranded; 1 x 7 AWG (4 mm) solid
Weight: 18 oz (510 g)
Color: Red
Internal Switches: Dual/Single Selector; Manual/Auto Selector
Indication: LED 1 Red = Power On LED 3 Green = K2 Closed
LED 2 Green = K 1 Closed LED 4 Yellow = Single-channel mode
Mechanical Life: 1 x 106 Operations
Environmental
Enclosure Protection: NEMA 1 (IP40)
Operating Temperature: 14°F to 131°F (-10°C to 55°C)
Humidity: 90% RH at 122°F (50°C)
safety monitoring relays
Specifications are subject to change without notice.
Note: The safety contacts of the STI switches are described as normally closed (N/C)—i.e., with the guard closed, actuator in place, and the machine
able to be started.
■ Ordering
Model Supply Inputs Outputs Auxiliary Part No.
SR06AM24 24 VAC/DC 2 N/C 3 N/O 1 N/C 44510-0330
SR06AM110 110 VAC 2 N/C 3 N/O 1 N/C 44510-0320
SR06AM220 220 VAC 2 N/C 3 N/O 1 N/C 44510-0310
Replacement Fuse (500 mA) 44512-0340
For the Latest Information
Try Our Fax Back System at 1/916/431-6544
On the Internet: www.sti.com E-mail: sales@sti.com
Scientific Technologies Inc. STI Scientific Technologies GmbH
Fremont, CA R
Freiburg, Germany
Tel. 1/510/608-3400 1/888/510-4357 F11 Tel. +49-761-455 26 0