100% found this document useful (1 vote)
613 views8 pages

DSU Catalog 2019

Voltas provides comprehensive life cycle support for their ducted air conditioning systems through managed services including remote monitoring, digital service reports, and 24/7 helpdesk support. They have a national service network across India to enable easy and quick customer satisfaction. Their ductable split AC units are available in both air-cooled and water-cooled options and are designed for applications such as offices, banks, department stores, and more.

Uploaded by

YUVI RAJ
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
613 views8 pages

DSU Catalog 2019

Voltas provides comprehensive life cycle support for their ducted air conditioning systems through managed services including remote monitoring, digital service reports, and 24/7 helpdesk support. They have a national service network across India to enable easy and quick customer satisfaction. Their ductable split AC units are available in both air-cooled and water-cooled options and are designed for applications such as offices, banks, department stores, and more.

Uploaded by

YUVI RAJ
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

Voltas Customer Care

Life Cycle Support


Through MANAGED Services Microprocessor-Controlled
Ducted Systems
R410a R407c
Remote Monitoring Digital Service Reports 24x7 Helpdesk
Green Refrigerants*

Voltas is ‘Grade 1’
Energy Service Company (ESCO)
Chandigarh
BMS Compatible Ductable Split AC
Delhi
Pantnagar
Voltas National Network
Easy Access Quick Satisfaction
Jaipur Lucknow Guwahati
Customer Care
Varanasi
1800 233 1202 or 1800 266 0100
Ahmedabad Durgapur
Jamnagar Indore Jamshedpur
Kolkata
Vapi Nagpur Raipur MEP Services :
Aurangabad • Electro-mechanical Services
Bhubaneshwar
Mumbai
Pune
• HVAC
Hyderabad • Refrigeration
Vishakhapatnam

Vijayawada
Goa Hubli Water and
Wastewater
Bangalore
Chennai MAIN PLANT Management
SALES HEADQUARTERS
Coimbatore
ZONAL OFFICES
Kochi
Madurai BRANCH OFFICES Value Added
Thiruvananthapuram
AREA OFFICES Services

VOLTAS LIMITED
Domesc Projects Group, Voltas House 'B’, 3rd floor, T. B. Kadam Marg, Chinchpokli, Mumbai-400 033, India
Tel: +91 22 6665 6857. Email: bijogeorge@voltas.com, gauravrohilla@voltas.com, janpanchal@voltas.com,
shubhambahadkar@voltas.com, North: psnorth@voltas.com, East: pseast@voltas.com,
South: pssouth@voltas.com, West: pswest@voltas.com
VL/MC-PDSU/05/19

Website: www.voltas.com

NORTH ZONE: DELHI (011) 66505659/66505678/66505680/66505657 CHANDIGARH (0172) 411800 JAIPUR (0141) 6541011 LUCKNOW
8840739788 EAST ZONE: KOLKATA (033) 66266268 / 662662283 / 66266262 BHUBANESHWAR (0674) 2747868 PATNA (0612) 2500786 RAIPUR (077)
14033886 WEST ZONE: MUMBAI (022) 66656754/ 66656756 / 66656757 / 66656759 / 66656760 NAGPUR (0712) 6456894 AHMEDABAD (079)
66301102 / 6630 1107 PUNE (020) 66297446 INDORE (0731) 2498616 SOUTH ZONE: CHENNAI (044) 66762357 / 66760346 / 66760355 BENGALURU (080)
22535648 HYDERABAD (040) 66743007 COCHIN (0484) 6605527.
* Opons available
THE VOLTAS INTELLISYS RANGE FEW OF OUR INSTALLATIONS
The Voltas INTELLISYS range of Ductable Split Units are designed to be the most INTELLIGENT and
COMPACT systems, to cater to your total cooling requirements. Applicaons include offices, banks,
departmental stores, entertainment centres, mulplexes, restaurants, fast food centres, residences,
computer rooms, telephone exchanges, hospitals, auditoriums, conference halls, theatres, factories,
control rooms, etc. Ductable Split Units are available in both Air-cooled and Water-cooled opons.

POWERFUL FEATURES
Energy Efficiency
A range of sophiscated components such as a highly energy efficient compressor, internally grooved
crosshatched copper tube coil with matched circuitry, and a microprocessor controller, result in a low
power consumpon.

Low Noise, Compact Indoor & Outdoor Units


Superior engineering coupled with technologically advanced components; ensure low noise levels, indoors
NATIONAL LAW UNIVERSITY P&M MALL VIT UNIVERSITY
and outdoors. Our new design IDUs and ODUs are more compact, saving valuable space.
AMPHITHEATRE

Higher False Ceiling Heights


Low height IDUs enable higher false ceiling heights, improving the aesthecs.

Equalizaon Of Compressor Runme


The Microprocessor Controller ensures equal running of compressors in mulple compressor units. This
ensures a longer life for compressors.

Space Saving
The outdoor condensing unit, in a ductable split unit, is a compact unit and can be placed on a ledge,
terrace or a wall-mounted bracket. The indoor unit can be ceiling-suspended or lo-mounted, a unique
advantage. BURGER KING NAJRUL TIRTHA SHREE NARAYANA STUDIO

Indoor Air Quality


Special synthec woven filters remove fine dust parcles to give clean air at all mes. The filters are easily
removable and washable.

Humidity Control
A highly-efficient evaporator coil keeps the room humidity within the desired comfort range.

Reliability
Our manufacturing plants are equipped with the latest and sophiscated tooling and machinery, backed by
a modern R&D facility. The products are best-in-class, designed especially for tropical condions, with high
levels of reliability.
RAJMAHAL RESORTS PARADISE RESTAURANT SYDNEY HEIGHTS RESORTS

Blue Fin treatment


Hydrophilic fins and inner-grooved copper pipes are standard feature which provides resistance to
corrosion & opmizes heat exchange / efficiency.
TECHNICAL DATA - THERMO SERIES DUCTABLE SPLIT UNITS MICROPROCESSOR - BASED LCD CONTROLLER FOR DUCTABLE UNITS
The BMS Compable Microprocessor based controller installed in all the units, offers you the following benefits:
SCROLL COMPRESSOR UNITS (R22/R407C)
Nominal Capacity TR 5.5 TR 8.75 TR 11.0 TR 17.0TR

ard Feature
No. of Compressor 1 1 2 2
EVAPORATOR UNITS (INDOOR UNIT) nd

Also as Sta
Model ACDEU55CZGIM ACDEU85CZGIM ACDEU110CZGIM ACDEU170CZGIM
Airflow CMH 3740 5780 7480 11560 Auto Start mode
Evaporator Fan Centrifugal Forward Curved Fan, Double Inlet Double Width For automatic start, after a
Power Supply V/Ph/Hz 230V / 1PH / 50Hz (2 Wire, AC Supply) power failure. (User can
BMS Compability
Length mm 1130 1508 1820 2020 enable and disable Large LCD screen
Control & Monitor AC with
Depth mm 750 795 780 750 Computer-based systems
according to the Blue/White backlit LCD for
Height mm 475 404 475 575 on RS485.
requirement) easy readability.
Net weight kg 70 88 117 181
AIR-COOLED CONDENSING UNITS (OUTDOOR UNIT)
Model (R22) ACDCUA05511D-HS ACDCUA08711D-HS ACDCUA05511D-HS ACDCUA08711D-HS Inbuilt 4 modes of
Model (R407c) ACDCUA05512D-HS ACDCUA08712D-HS ACDCUA05512D-HS ACDCUA08712D-HS Temperature sensor Operaon
Power Supply V/Ph/Hz 415 V - 3 PH - 50 Hz (4 Wire, AC Supply) For precise control within Cool, Dry, Fan and Energy Save.
No. of Units 1 1 2 2 +/- 0.5deg C
Condenser fan Axial
No. of Fans/CU 1 1 1 1
Length/CU mm 1200 1550 1200 1550
Depth/CU mm 450 575 450 575
Motor protecon device
Height/CU mm 960 960 960 960 On /Off mer
For protecon from
Net weight/CU kg 132 166 132 166 As a standard feature
phase reversal, single
for seng the start and
"NOTES: phasing, over-load and
1) The nominal capacies menoned are at the rang condions for stop me in a day.
-Air Cooled Unit: Indoor Temperature: 27°C DBT /19°C WBT, and Outdoor Temperature: 35°C DBT for Air-cooled condensers and condensing units.
phase Imbalances.
2) THERMO Units can operate upto maximum ambient temperature of 52°C.
3) The Gas charging at Factory is as per standard connecon distance between ODU & IDU. For extra lengths, Gas topping up at site is required.
4) Please contact VOLTAS sales representave for condensing units with Microchannel Heat exchangers.
Energy saving
Special Energy Save Mode
Fan speed selecon available to run unit efficiently.
TECHNICAL DATA - TROPICO SERIES DUCTABLE SPLIT UNITS Low, Medium, High, Auto. Auto switch-off of the condenser
fans along with compressor
An-recycle mer Self-Diagnosis
For starng the funcon
SCROLL COMPRESSOR UNITS (R22/R407C) compressor aer a set Constant monitoring of
Nominal Capacity TR 5.5 TR 8.75 TR 11.0 TR 17.0TR delay, to enhance its life. errors with alarms.
No. of Compressor 1 1 2 2
EVAPORATOR UNITS
Model ACDEU55CZGHSIM ACDEU85CZGHSIM ACDEU110CZGHSIM ACDEU170CZGHSIM
Airflow CMH 5780 7480 11560 14960
Evaporator Fan Centrifugal Forward Curved Fan, Double Inlet Double Width
Power Supply V/Ph/Hz 230V / 1PH / 50Hz (2 Wire, AC Supply)
Length mm 1508 1820 2020 2100
Depth mm 795 780 750 1240
Height mm 404 475 575 640

BMS WIRING DIAGRAM (MODBUS)


Net weight kg 88 117 181 291
AIR-COOLED CONDENSING UNITS
Model (R22) ACDCUA05511D-HS ACDCUA08711D-HS ACDCUA05511D-HS ACDCUA08711D-HS
Model (R407c) ACDCUA05512D-HS ACDCUA08712D-HS ACDCUA05512D-HS ACDCUA08712D-HS LF MF HF L(R) L (R) N N LF MF HF L(R) L (R) N N LF MF HF L(R) L (R) N N LF MF HF L(R) L (R) N N

FAN AC220/240V FAN AC220/240V FAN AC220/240V FAN AC220/240V


OUTPUT POWER SUPPLY OUTPUT POWER SUPPLY OUTPUT POWER SUPPLY OUTPUT POWER SUPPLY

Power Supply V/Ph/Hz 415 V - 3 PH - 50 Hz (4 Wire, AC Supply)


No. of Units 1 1 2 2 ROOM T.
SENSOR
HANDSET
REMOCON
RS485
BMS
ROOM T.
SENSOR
HANDSET
REMOCON
RS485
BMS
ROOM T.
SENSOR
HANDSET
REMOCON
RS485
BMS
ROOM T.
SENSOR
HANDSET
REMOCON
RS485
BMS

G- 12V T R B A G- 12V T R B A G- 12V T R B A G- 12V T R B A

Condenser fan Axial


No. of Fans/CU 1 1 1 1 B A
UPTO 64 INDOOR UNITS
B A B A B A

Length/CU mm 1200 1550 1200 1550


Depth/CU mm 450 575 450 575
Height/CU mm 960 960 960 960 MONITORS CONTROLS
Net weight/CU kg 132 166 132 166 Room Temperature Run Mode (Cool / Dry / Fan mode)
RS485 TO USB Current Fan Statues Set Temperature (16-30ºC)
"NOTES:
CONVERTER Compressor run Statues Fan Speed Set (Auto / Hi / Med / Lo)
1) The nominal capacies menoned are at the rang condions for
-Air Cooled Unit: Indoor Temperature: 27°C DBT /19°C WBT, and Outdoor Temperature: 35°C DBT for Air-cooled condensers and condensing units. Alarm Code Wired Remote Key Lock
2) TROPICO Units can operate upto maximum ambient temperature of 52°C.
3) The Gas charging at Factory is as per standard connecon distance between ODU & IDU. For extra lengths, Gas topping up at site is required.
4) Please contact VOLTAS sales representave for condensing units with Microchannel Heat exchangers.
BMS PC
Product design and innovaon are a connuous process in VOLTAS and hence the above specificaons are subject to change without noce.
TECHNICAL DATA - AIR COOLED & WATER COOLED UNITS TECHNICAL DATA - AIR COOLED UNITS

SCROLL COMPRESSOR UNITS (R22/R407C) SCROLL COMPRESSOR UNITS (R410A)


Nominal Capacity TR 5.5 TR 8.5 TR 8.75 TR 11.0 TR 11.0 TR 17.0TR 22.0 TR Nominal Capacity TR 6.0 TR 9.0 TR 12.0TR 12.0 TR 18.0TR
No. of Compressor 1 1 1 2 2
No. of Compressor 1 2 1 2 1 2 2
EVAPORATOR UNITS
EVAPORATOR UNITS Model ACDEU60CZGIMCR410 ACDEU90CZGIMR410 ACDEU120C1ZGIMR410 ACDEU120CZGIMR410 ACDEU180CZGIMR410
Airflow CMH 3900 6120 7800 7800 11700
Model ACDEU55CZGIMC ACDEU85C2ZG ACDEU85CZGIM ACDEU110CZGIM ACDEU110C1ZGIM ACDEU170CZGIM ACDEU220CKGIM
Evaporator Fan Centrifugal Forward Curved Fan, Double Inlet Double Width
Airflow CMH 3740 5780 5780 7480 7480 11560 14960
Power Supply V/Ph/Hz 230V - 1PH - 50Hz (2 Wire, AC Supply)
Evaporator Fan Centrifugal Forward Curved Fan, Double Inlet Double Width Length mm 1228 1508 1820 1820 2020
Depth mm 665 750 780 780 750
Power Supply V/Ph/Hz 230V / 1PH / 50Hz (2 Wire, AC Supply)
Height mm 404 475 475 475 575
Length mm 1228 1508 1508 1820 1820 2020 2100 Net weight kg 65 90 110 110 180
Depth mm 665 795 795 780 780 750 1240 AIR-COOLED CONDENSING UNITS
Model ACDCUSC60DGIMR410 ACDCUSC90DGIMR410 ACDCUSC120DGIMR410 ACDCUSC60DGIMR410 ACDCUSC90DGIMR410
Height mm 404 404 404 475 475 575 640
Power Supply V/Ph/Hz 415 V - 3 PH - 50 Hz (4 Wire, AC Supply)
Net weight kg 65 81 88 117 112 181 291 No. of Units 1 1 1 2 2
AIR-COOLED CONDENSING UNITS Condenser fan Axial Axial Axial Axial Axial
No. of Fans/CU 1 1 2 1 1
Model (R22) ACDCUA05511D - ACDCUA08711D ACDCUA05511D ACDCUA11011D ACDCUA08711D ACDCUA11011D
Length/CU mm 950 1200 1550 950 1200
Model (R22) ACDCUA05511Y ACDCUSC2875Y - ACDCUA05511Y - - - Depth/CU mm 450 450 575 450 450

Model (R407c) ACDCUA05512D - ACDCUA08712D ACDCUA05512D ACDCUA11012D ACDCUA08712D ACDCUA11012D Height/CU mm 960 960 960 960 960
Net weight/CU kg 90 130 160 90 130
Power Supply V/Ph/Hz 415 V - 3 PH - 50 Hz (4 Wire, AC Supply)
"NOTES:
No. of Units 1 1 1 2 1 2 2 1) The nominal capacies menoned are at the rang condions for
-Air Cooled Unit: Indoor Temperature: 27°C DBT /19°C WBT, and Outdoor Temperature: 35°C DBT for Air-cooled condensers and condensing units.
2) Air Cooled Units can operate upto maximum ambient temperature of 48°C.
Condenser fan Axial Axial Axial Axial Axial Axial Axial 3) The Gas charging at Factory is as per standard connecon distance between ODU & IDU. For extra lengths, Gas topping up at site is required.
4) Please contact VOLTAS sales representave for units below 5.5TR capacity.
No. of Fans/CU 1 1 1 1 2 1 2

Length/CU

Depth/CU
mm

mm
950

450
1320

460
1200

450
950

450
1550

575
1200

450
1550

575
TECHNICAL DATA - AERO SERIES DUCTABLE SPLIT UNITS
Height/CU mm 960 960 960 960 960 960 960
SCROLL COMPRESSOR UNITS (R22/R407C)
Net weight/CU kg 120 161 132 120 186 132 186
Nominal Capacity TR 5.5 TR 8.75 TR 11.0 TR 17.0TR
WATER-COOLED CONDENSING UNITS No. of Compressor 1 1 2 2

Model (R22) ACDCUWSC55IM - ACDCUWSC875DIM ACDCUWSC55IM - ACDCUWSC875DIM -


EVAPORATOR UNITS (INDOOR UNIT)
Model ACDEU55CZGHSIM ACDEU85CZGHSIM ACDEU110CZGHSIM ACDEU170CZGHSIM
Model (R407c) ACDCUWSC55R407IM - ACDCUWSC875DR407IM ACDCUWSC55R407IM - ACDCUWSC875DR407IM -
Airflow CMH 5780 7480 11560 14960
Power Supply 415 V - 3 PH - 50 Hz (4 Wire, AC Supply) Evaporator Fan Centrifugal Forward Curved Fan, Double Inlet Double Width
Power Supply V/Ph/Hz 230V / 1PH / 50Hz (2 Wire, AC Supply)
No. of Units 1 - 1 2 - 2 -
Length mm 1508 1820 2020 2100
Condenser Water (In/Out) in. 1-1/4" BSP - 1-1/4" BSP 1-1/4" BSP - 1-1/4" BSP -
Depth mm 795 780 750 1240
Water Flow Rate/CU LPM 73 - 113 73 - 113 - Height mm 404 475 575 640
Net weight kg 88 117 181 291
Length/CU mm 900 - 900 900 - 900 -
AIR-COOLED CONDENSING UNITS (OUTDOOR UNIT)
Depth/CU mm 665 - 665 665 - 665 - Model (R22) ACDCUA05511D ACDCUA08711D ACDCUA05511D ACDCUA08711D
Height/CU mm 615 - 615 615 - 615 - Model (R407c) ACDCUA05512D ACDCUA08712D ACDCUA05512D ACDCUA08712D
Power Supply V/Ph/Hz 415 V - 3 PH - 50 Hz (4 Wire, AC Supply)
Net weight/CU kg 120 - 190 120 - 120 -
No. of Units 1 1 2 2

"NOTES: Condenser fan Axial Axial Axial Axial


1) The nominal capacies menoned are at the rang condions for No. of Fans/CU 1 1 1 1
-Air Cooled Unit: Indoor Temperature: 27°C DBT /19°C WBT, and Outdoor Temperature: 35°C DBT for Air-cooled condensers and condensing units.
-Water Cooled Unit: Indoor Temperature: 27°C DBT /19°C WBT, and Water Inlet temperature: 32°C at rated water flow Length/CU mm 950 1200 950 1200
2) Air Cooled Units can operate upto maximum ambient temperature of 48°C. Depth/CU mm 450 450 450 450
3) The Gas charging at Factory is as per standard connecon distance between ODU & IDU. For extra lengths, Gas topping up at site is required.
Height/CU mm 960 960 960 960
4) Please contact VOLTAS sales representave for units below 5.5TR capacity & Condensing Units with Microchannel Heat exchangers.
Net weight/CU kg 120 132 120 132
Product design and innovaon are a connuous process in VOLTAS and hence the above specificaons are subject to change without noce.
"NOTES:
1) The nominal capacies menoned are at the rang condions for
-Air Cooled Unit: Indoor Temperature: 27°C DBT /19°C WBT, and Outdoor Temperature: 35°C DBT for Air-cooled condensers and condensing units.
2) AERO Units can operate upto maximum ambient temperature of 48°C.
3) The Gas charging at Factory is as per standard connecon distance between ODU & IDU. For extra lengths, Gas topping up at site is required.
4) Please contact VOLTAS sales representave for condensing units with Microchannel Heat exchangers.

Product design and innovaon are a connuous process in VOLTAS and hence the above specificaons are subject to change without noce.
TECHNICAL DATA - AIR COOLED & WATER COOLED UNITS TECHNICAL DATA - AIR COOLED UNITS

SCROLL COMPRESSOR UNITS (R22/R407C) SCROLL COMPRESSOR UNITS (R410A)


Nominal Capacity TR 5.5 TR 8.5 TR 8.75 TR 11.0 TR 11.0 TR 17.0TR 22.0 TR Nominal Capacity TR 6.0 TR 9.0 TR 12.0TR 12.0 TR 18.0TR
No. of Compressor 1 1 1 2 2
No. of Compressor 1 2 1 2 1 2 2
EVAPORATOR UNITS
EVAPORATOR UNITS Model ACDEU60CZGIMCR410 ACDEU90CZGIMR410 ACDEU120C1ZGIMR410 ACDEU120CZGIMR410 ACDEU180CZGIMR410
Airflow CMH 3900 6120 7800 7800 11700
Model ACDEU55CZGIMC ACDEU85C2ZG ACDEU85CZGIM ACDEU110CZGIM ACDEU110C1ZGIM ACDEU170CZGIM ACDEU220CKGIM
Evaporator Fan Centrifugal Forward Curved Fan, Double Inlet Double Width
Airflow CMH 3740 5780 5780 7480 7480 11560 14960
Power Supply V/Ph/Hz 230V - 1PH - 50Hz (2 Wire, AC Supply)
Evaporator Fan Centrifugal Forward Curved Fan, Double Inlet Double Width Length mm 1228 1508 1820 1820 2020
Depth mm 665 750 780 780 750
Power Supply V/Ph/Hz 230V / 1PH / 50Hz (2 Wire, AC Supply)
Height mm 404 475 475 475 575
Length mm 1228 1508 1508 1820 1820 2020 2100 Net weight kg 65 90 110 110 180
Depth mm 665 795 795 780 780 750 1240 AIR-COOLED CONDENSING UNITS
Model ACDCUSC60DGIMR410 ACDCUSC90DGIMR410 ACDCUSC120DGIMR410 ACDCUSC60DGIMR410 ACDCUSC90DGIMR410
Height mm 404 404 404 475 475 575 640
Power Supply V/Ph/Hz 415 V - 3 PH - 50 Hz (4 Wire, AC Supply)
Net weight kg 65 81 88 117 112 181 291 No. of Units 1 1 1 2 2
AIR-COOLED CONDENSING UNITS Condenser fan Axial Axial Axial Axial Axial
No. of Fans/CU 1 1 2 1 1
Model (R22) ACDCUA05511D - ACDCUA08711D ACDCUA05511D ACDCUA11011D ACDCUA08711D ACDCUA11011D
Length/CU mm 950 1200 1550 950 1200
Model (R22) ACDCUA05511Y ACDCUSC2875Y - ACDCUA05511Y - - - Depth/CU mm 450 450 575 450 450

Model (R407c) ACDCUA05512D - ACDCUA08712D ACDCUA05512D ACDCUA11012D ACDCUA08712D ACDCUA11012D Height/CU mm 960 960 960 960 960
Net weight/CU kg 90 130 160 90 130
Power Supply V/Ph/Hz 415 V - 3 PH - 50 Hz (4 Wire, AC Supply)
"NOTES:
No. of Units 1 1 1 2 1 2 2 1) The nominal capacies menoned are at the rang condions for
-Air Cooled Unit: Indoor Temperature: 27°C DBT /19°C WBT, and Outdoor Temperature: 35°C DBT for Air-cooled condensers and condensing units.
2) Air Cooled Units can operate upto maximum ambient temperature of 48°C.
Condenser fan Axial Axial Axial Axial Axial Axial Axial 3) The Gas charging at Factory is as per standard connecon distance between ODU & IDU. For extra lengths, Gas topping up at site is required.
4) Please contact VOLTAS sales representave for units below 5.5TR capacity.
No. of Fans/CU 1 1 1 1 2 1 2

Length/CU

Depth/CU
mm

mm
950

450
1320

460
1200

450
950

450
1550

575
1200

450
1550

575
TECHNICAL DATA - AERO SERIES DUCTABLE SPLIT UNITS
Height/CU mm 960 960 960 960 960 960 960
SCROLL COMPRESSOR UNITS (R22/R407C)
Net weight/CU kg 120 161 132 120 186 132 186
Nominal Capacity TR 5.5 TR 8.75 TR 11.0 TR 17.0TR
WATER-COOLED CONDENSING UNITS No. of Compressor 1 1 2 2

Model (R22) ACDCUWSC55IM - ACDCUWSC875DIM ACDCUWSC55IM - ACDCUWSC875DIM -


EVAPORATOR UNITS (INDOOR UNIT)
Model ACDEU55CZGHSIM ACDEU85CZGHSIM ACDEU110CZGHSIM ACDEU170CZGHSIM
Model (R407c) ACDCUWSC55R407IM - ACDCUWSC875DR407IM ACDCUWSC55R407IM - ACDCUWSC875DR407IM -
Airflow CMH 5780 7480 11560 14960
Power Supply 415 V - 3 PH - 50 Hz (4 Wire, AC Supply) Evaporator Fan Centrifugal Forward Curved Fan, Double Inlet Double Width
Power Supply V/Ph/Hz 230V / 1PH / 50Hz (2 Wire, AC Supply)
No. of Units 1 - 1 2 - 2 -
Length mm 1508 1820 2020 2100
Condenser Water (In/Out) in. 1-1/4" BSP - 1-1/4" BSP 1-1/4" BSP - 1-1/4" BSP -
Depth mm 795 780 750 1240
Water Flow Rate/CU LPM 73 - 113 73 - 113 - Height mm 404 475 575 640
Net weight kg 88 117 181 291
Length/CU mm 900 - 900 900 - 900 -
AIR-COOLED CONDENSING UNITS (OUTDOOR UNIT)
Depth/CU mm 665 - 665 665 - 665 - Model (R22) ACDCUA05511D ACDCUA08711D ACDCUA05511D ACDCUA08711D
Height/CU mm 615 - 615 615 - 615 - Model (R407c) ACDCUA05512D ACDCUA08712D ACDCUA05512D ACDCUA08712D
Power Supply V/Ph/Hz 415 V - 3 PH - 50 Hz (4 Wire, AC Supply)
Net weight/CU kg 120 - 190 120 - 120 -
No. of Units 1 1 2 2

"NOTES: Condenser fan Axial Axial Axial Axial


1) The nominal capacies menoned are at the rang condions for No. of Fans/CU 1 1 1 1
-Air Cooled Unit: Indoor Temperature: 27°C DBT /19°C WBT, and Outdoor Temperature: 35°C DBT for Air-cooled condensers and condensing units.
-Water Cooled Unit: Indoor Temperature: 27°C DBT /19°C WBT, and Water Inlet temperature: 32°C at rated water flow Length/CU mm 950 1200 950 1200
2) Air Cooled Units can operate upto maximum ambient temperature of 48°C. Depth/CU mm 450 450 450 450
3) The Gas charging at Factory is as per standard connecon distance between ODU & IDU. For extra lengths, Gas topping up at site is required.
Height/CU mm 960 960 960 960
4) Please contact VOLTAS sales representave for units below 5.5TR capacity & Condensing Units with Microchannel Heat exchangers.
Net weight/CU kg 120 132 120 132
Product design and innovaon are a connuous process in VOLTAS and hence the above specificaons are subject to change without noce.
"NOTES:
1) The nominal capacies menoned are at the rang condions for
-Air Cooled Unit: Indoor Temperature: 27°C DBT /19°C WBT, and Outdoor Temperature: 35°C DBT for Air-cooled condensers and condensing units.
2) AERO Units can operate upto maximum ambient temperature of 48°C.
3) The Gas charging at Factory is as per standard connecon distance between ODU & IDU. For extra lengths, Gas topping up at site is required.
4) Please contact VOLTAS sales representave for condensing units with Microchannel Heat exchangers.

Product design and innovaon are a connuous process in VOLTAS and hence the above specificaons are subject to change without noce.
TECHNICAL DATA - THERMO SERIES DUCTABLE SPLIT UNITS MICROPROCESSOR - BASED LCD CONTROLLER FOR DUCTABLE UNITS
The BMS Compable Microprocessor based controller installed in all the units, offers you the following benefits:
SCROLL COMPRESSOR UNITS (R22/R407C)
Nominal Capacity TR 5.5 TR 8.75 TR 11.0 TR 17.0TR

ard Feature
No. of Compressor 1 1 2 2
EVAPORATOR UNITS (INDOOR UNIT) nd

Also as Sta
Model ACDEU55CZGIM ACDEU85CZGIM ACDEU110CZGIM ACDEU170CZGIM
Airflow CMH 3740 5780 7480 11560 Auto Start mode
Evaporator Fan Centrifugal Forward Curved Fan, Double Inlet Double Width For automatic start, after a
Power Supply V/Ph/Hz 230V / 1PH / 50Hz (2 Wire, AC Supply) power failure. (User can
BMS Compability
Length mm 1130 1508 1820 2020 enable and disable Large LCD screen
Control & Monitor AC with
Depth mm 750 795 780 750 Computer-based systems
according to the Blue/White backlit LCD for
Height mm 475 404 475 575 on RS485.
requirement) easy readability.
Net weight kg 70 88 117 181
AIR-COOLED CONDENSING UNITS (OUTDOOR UNIT)
Model (R22) ACDCUA05511D-HS ACDCUA08711D-HS ACDCUA05511D-HS ACDCUA08711D-HS Inbuilt 4 modes of
Model (R407c) ACDCUA05512D-HS ACDCUA08712D-HS ACDCUA05512D-HS ACDCUA08712D-HS Temperature sensor Operaon
Power Supply V/Ph/Hz 415 V - 3 PH - 50 Hz (4 Wire, AC Supply) For precise control within Cool, Dry, Fan and Energy Save.
No. of Units 1 1 2 2 +/- 0.5deg C
Condenser fan Axial
No. of Fans/CU 1 1 1 1
Length/CU mm 1200 1550 1200 1550
Depth/CU mm 450 575 450 575
Motor protecon device
Height/CU mm 960 960 960 960 On /Off mer
For protecon from
Net weight/CU kg 132 166 132 166 As a standard feature
phase reversal, single
for seng the start and
"NOTES: phasing, over-load and
1) The nominal capacies menoned are at the rang condions for stop me in a day.
-Air Cooled Unit: Indoor Temperature: 27°C DBT /19°C WBT, and Outdoor Temperature: 35°C DBT for Air-cooled condensers and condensing units.
phase Imbalances.
2) THERMO Units can operate upto maximum ambient temperature of 52°C.
3) The Gas charging at Factory is as per standard connecon distance between ODU & IDU. For extra lengths, Gas topping up at site is required.
4) Please contact VOLTAS sales representave for condensing units with Microchannel Heat exchangers.
Energy saving
Special Energy Save Mode
Fan speed selecon available to run unit efficiently.
TECHNICAL DATA - TROPICO SERIES DUCTABLE SPLIT UNITS Low, Medium, High, Auto. Auto switch-off of the condenser
fans along with compressor
An-recycle mer Self-Diagnosis
For starng the funcon
SCROLL COMPRESSOR UNITS (R22/R407C) compressor aer a set Constant monitoring of
Nominal Capacity TR 5.5 TR 8.75 TR 11.0 TR 17.0TR delay, to enhance its life. errors with alarms.
No. of Compressor 1 1 2 2
EVAPORATOR UNITS
Model ACDEU55CZGHSIM ACDEU85CZGHSIM ACDEU110CZGHSIM ACDEU170CZGHSIM
Airflow CMH 5780 7480 11560 14960
Evaporator Fan Centrifugal Forward Curved Fan, Double Inlet Double Width
Power Supply V/Ph/Hz 230V / 1PH / 50Hz (2 Wire, AC Supply)
Length mm 1508 1820 2020 2100
Depth mm 795 780 750 1240
Height mm 404 475 575 640

BMS WIRING DIAGRAM (MODBUS)


Net weight kg 88 117 181 291
AIR-COOLED CONDENSING UNITS
Model (R22) ACDCUA05511D-HS ACDCUA08711D-HS ACDCUA05511D-HS ACDCUA08711D-HS
Model (R407c) ACDCUA05512D-HS ACDCUA08712D-HS ACDCUA05512D-HS ACDCUA08712D-HS LF MF HF L(R) L (R) N N LF MF HF L(R) L (R) N N LF MF HF L(R) L (R) N N LF MF HF L(R) L (R) N N

FAN AC220/240V FAN AC220/240V FAN AC220/240V FAN AC220/240V


OUTPUT POWER SUPPLY OUTPUT POWER SUPPLY OUTPUT POWER SUPPLY OUTPUT POWER SUPPLY

Power Supply V/Ph/Hz 415 V - 3 PH - 50 Hz (4 Wire, AC Supply)


No. of Units 1 1 2 2 ROOM T.
SENSOR
HANDSET
REMOCON
RS485
BMS
ROOM T.
SENSOR
HANDSET
REMOCON
RS485
BMS
ROOM T.
SENSOR
HANDSET
REMOCON
RS485
BMS
ROOM T.
SENSOR
HANDSET
REMOCON
RS485
BMS

G- 12V T R B A G- 12V T R B A G- 12V T R B A G- 12V T R B A

Condenser fan Axial


No. of Fans/CU 1 1 1 1 B A
UPTO 64 INDOOR UNITS
B A B A B A

Length/CU mm 1200 1550 1200 1550


Depth/CU mm 450 575 450 575
Height/CU mm 960 960 960 960 MONITORS CONTROLS
Net weight/CU kg 132 166 132 166 Room Temperature Run Mode (Cool / Dry / Fan mode)
RS485 TO USB Current Fan Statues Set Temperature (16-30ºC)
"NOTES:
CONVERTER Compressor run Statues Fan Speed Set (Auto / Hi / Med / Lo)
1) The nominal capacies menoned are at the rang condions for
-Air Cooled Unit: Indoor Temperature: 27°C DBT /19°C WBT, and Outdoor Temperature: 35°C DBT for Air-cooled condensers and condensing units. Alarm Code Wired Remote Key Lock
2) TROPICO Units can operate upto maximum ambient temperature of 52°C.
3) The Gas charging at Factory is as per standard connecon distance between ODU & IDU. For extra lengths, Gas topping up at site is required.
4) Please contact VOLTAS sales representave for condensing units with Microchannel Heat exchangers.
BMS PC
Product design and innovaon are a connuous process in VOLTAS and hence the above specificaons are subject to change without noce.
THE VOLTAS INTELLISYS RANGE FEW OF OUR INSTALLATIONS
The Voltas INTELLISYS range of Ductable Split Units are designed to be the most INTELLIGENT and
COMPACT systems, to cater to your total cooling requirements. Applicaons include offices, banks,
departmental stores, entertainment centres, mulplexes, restaurants, fast food centres, residences,
computer rooms, telephone exchanges, hospitals, auditoriums, conference halls, theatres, factories,
control rooms, etc. Ductable Split Units are available in both Air-cooled and Water-cooled opons.

POWERFUL FEATURES
Energy Efficiency
A range of sophiscated components such as a highly energy efficient compressor, internally grooved
crosshatched copper tube coil with matched circuitry, and a microprocessor controller, result in a low
power consumpon.

Low Noise, Compact Indoor & Outdoor Units


Superior engineering coupled with technologically advanced components; ensure low noise levels, indoors
NATIONAL LAW UNIVERSITY P&M MALL VIT UNIVERSITY
and outdoors. Our new design IDUs and ODUs are more compact, saving valuable space.
AMPHITHEATRE

Higher False Ceiling Heights


Low height IDUs enable higher false ceiling heights, improving the aesthecs.

Equalizaon Of Compressor Runme


The Microprocessor Controller ensures equal running of compressors in mulple compressor units. This
ensures a longer life for compressors.

Space Saving
The outdoor condensing unit, in a ductable split unit, is a compact unit and can be placed on a ledge,
terrace or a wall-mounted bracket. The indoor unit can be ceiling-suspended or lo-mounted, a unique
advantage. BURGER KING NAJRUL TIRTHA SHREE NARAYANA STUDIO

Indoor Air Quality


Special synthec woven filters remove fine dust parcles to give clean air at all mes. The filters are easily
removable and washable.

Humidity Control
A highly-efficient evaporator coil keeps the room humidity within the desired comfort range.

Reliability
Our manufacturing plants are equipped with the latest and sophiscated tooling and machinery, backed by
a modern R&D facility. The products are best-in-class, designed especially for tropical condions, with high
levels of reliability.
RAJMAHAL RESORTS PARADISE RESTAURANT SYDNEY HEIGHTS RESORTS

Blue Fin treatment


Hydrophilic fins and inner-grooved copper pipes are standard feature which provides resistance to
corrosion & opmizes heat exchange / efficiency.
Voltas Customer Care

Life Cycle Support


Through MANAGED Services Microprocessor-Controlled
Ducted Systems
R410a R407c
Remote Monitoring Digital Service Reports 24x7 Helpdesk
Green Refrigerants*

Voltas is ‘Grade 1’
Energy Service Company (ESCO)
Chandigarh
BMS Compatible Ductable Split AC
Delhi
Pantnagar
Voltas National Network
Easy Access Quick Satisfaction
Jaipur Lucknow Guwahati
Customer Care
Varanasi
1800 233 1202 or 1800 266 0100
Ahmedabad Durgapur
Jamnagar Indore Jamshedpur
Kolkata
Vapi Nagpur Raipur MEP Services :
Aurangabad • Electro-mechanical Services
Bhubaneshwar
Mumbai
Pune
• HVAC
Hyderabad • Refrigeration
Vishakhapatnam

Vijayawada
Goa Hubli Water and
Wastewater
Bangalore
Chennai MAIN PLANT Management
SALES HEADQUARTERS
Coimbatore
ZONAL OFFICES
Kochi
Madurai BRANCH OFFICES Value Added
Thiruvananthapuram
AREA OFFICES Services

VOLTAS LIMITED
Domesc Projects Group, Voltas House 'B’, 3rd floor, T. B. Kadam Marg, Chinchpokli, Mumbai-400 033, India
Tel: +91 22 6665 6857. Email: bijogeorge@voltas.com, gauravrohilla@voltas.com, janpanchal@voltas.com,
shubhambahadkar@voltas.com, North: psnorth@voltas.com, East: pseast@voltas.com,
South: pssouth@voltas.com, West: pswest@voltas.com
VL/MC-PDSU/05/19

Website: www.voltas.com

NORTH ZONE: DELHI (011) 66505659/66505678/66505680/66505657 CHANDIGARH (0172) 4111800 JAIPUR (0141) 6541011 LUCKNOW
8840739788 EAST ZONE: KOLKATA (033) 66266268 / 662662283 / 66266262 BHUBANESHWAR (0674) 2747868 PATNA (0612) 2500786 RAIPUR (077)
14033886 WEST ZONE: MUMBAI (022) 66656754/ 66656756 / 66656757 / 66656759 / 66656760 NAGPUR (0712) 6456894 AHMEDABAD (079)
66301102 / 6630 1107 PUNE (020) 66297446 INDORE (0731) 2498616 SOUTH ZONE: CHENNAI (044) 66762357 / 66760346 / 66760355 BENGALURU (080)
22535648 HYDERABAD (040) 66743007 COCHIN (0484) 6605527.
* Opons available

You might also like