0% found this document useful (0 votes)
105 views2 pages

Cable 3 X50

This document provides specifications for a 3-core copper cable with a rated voltage of 3.6/6 kV. The cable has a stranded copper conductor, XLPE insulation, a semi-conductor screen, PVC separation sheath, galvanized steel wire armour, and a PVC outer protective sheath. The cable is designed to operate at temperatures up to 90°C, withstand flames and hydrocarbons, and be resistant to UV light aging. It has theoretical electrical characteristics including current ratings, reactance, short-circuit withstand, voltage drop, and impedance.

Uploaded by

Jalal Albadri
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
105 views2 pages

Cable 3 X50

This document provides specifications for a 3-core copper cable with a rated voltage of 3.6/6 kV. The cable has a stranded copper conductor, XLPE insulation, a semi-conductor screen, PVC separation sheath, galvanized steel wire armour, and a PVC outer protective sheath. The cable is designed to operate at temperatures up to 90°C, withstand flames and hydrocarbons, and be resistant to UV light aging. It has theoretical electrical characteristics including current ratings, reactance, short-circuit withstand, voltage drop, and impedance.

Uploaded by

Jalal Albadri
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

ITEM 124

115 Cable

CU/XLPE/CTS/PVC/SWA/PVC
D1 - rev:00 3.6/6 kV
Date : 25.03.2021

M.V. POWER CABLE Max core temperature: 90°C

Design

1 Conductor 6 Separation sheath


Stranded annealed round Polyvinyl Chloride (PVC)
plain copper (Class 2) coloured natural

2 Conductor screen 7 Metallic armour


Extruded semi-conductor Galvanized steel wires (GSWA)

3 Insulation 8 Protective sheath


Cross-linked polyethylene (XLPE) Polyvinyl Chloride (PVC)
coloured red
4 Insulation screen
Extruded semi-conductor (Strippable)
Copper tape
(coverage: 100%)

5 Assembling
Inner covering acting as a
filler with practically
zero thickness

Marking (embossed) Core identification Standards


(Two lines embossed marking) 3x: red-yellow-blue IEC 60228
(by tape under copper screen) IEC 60502
NEXANS IEC 60502 IEC 60332-3-22
CU/XLPE/CTS/PVC/SWA/PVC
<Nb of cores & x-section> 3.6/6
kV 2021
+ METER MARKING

Ambient Good Oil&Hydrocarbon Flame retardant U.V. resistant


Temperature Resistant IEC 60332-3-22 ISO 4892-2
-20°C / +60°C (CAT A)

1/8
D1 - rev:00

THEORETICAL SIZE CHARACTERISTICS THEORETICAL ELECTRICAL CHARACTERISTICS

Current ratings based on IEC 60502-2


Conditions for installation underground (Single cable) - Thermal resistivity of soil: 1.5 K.m/W - Burying depth: 0.8 m
Conditions for installation in air (Single cable) - Horizontal

CONDUCTOR INSULATION ARMOUR PROTECTIVE SHEATH BENDING RESISTANCE CURRENT RATING REACTANCE SHORT-CIRCUIT CURRENT VOLTAGE DROP IMPEDANCE
POS N° NEXANS N° DESIGNATION STANDARD VOLTAGE SECTION Class Diam. Thickness Thickness Diam. Thickness Outer Diameter RADIUS WEIGHT DC AC in free air underground 50Hz 0.3 s 1s AC 50Hz
RATE (approx) (nominal) (nominal) (approx.) (min.) (min.) (max.) (minimum) (approx.) at 20°C at Max°C at 30°C at 20°C approx. maximum maximum approx. approx.
mm² # mm mm mm mm mm mm mm mm kg/km /km /km A A /km kA kA V/A.km /km
1 60612658 CU/XLPE/CTS/PVC/SWA/PVC IEC 60502 3.6/6 kV 3x50 Class 2 8.1 2.5 2.5 * 1.80 46.6 51.5 588 4940 0.387 0.497 205 158 0.10 13.1 7.15 0.9 0.505

2/8