You are on page 1/ 10

Cord & Cordset

Industrial Cord 4

Index Page

Super Vu-Tron®
Single Conductor Type W
and Type RHH/RHW 27

Super Vu-Tron® Multi-


No longer are industrial cord Our industrial cord products Conductor Type W Round 28
products used only in coal carry a full range of listings
mines and industrial plants; and certifications with Super Vu-Tron® Type G
today typical applications Underwriters Laboratories, and Type G-GC Round 29
include providing temporary Inc. and the Canadian
power to jobsites, as well Standard Association. Super Vu-Tron®
as flexible power leads In addition, many products Canadian Type G
for installation in conduit. meet or exceed the and Type G-GC Round 30
requirements of UL, CSA,
General Cable’s role, as the OSHA, MSHA, ICEA
producer of the premiere Carolprene®
and other relevant Welding Cable 31
Carol® Brand industrial cord industry standards.
products, is to ensure that
new product development, Carol is simply the most Super Vu-Tron®
product innovation and accepted brand in the Welding Cable
quality not only keep pace industry, having proven Type RHH/RHW 32
with industry requirements, itself on the job time after
but also set the trends. time. Our industrial cord line Super Vu-Tron®
is the most comprehensive Entertainment Industry
in the industry, ensuring that and Stage Lighting Cable 33
the proper Carol product can
always be specified. Super Vu-Tron®
Single Conductor
Type W Extra-Flex 34

Super Vu-Tron® Diesel


Locomotive Cable
Type RHH/RHW 35

26
Cord & Cordset Industrial Cord

Super Vu-Tron® Single Conductor


Ž#5, 4YPE76OLTAND4YPE2((2(76OLT0ORTABLE0OWER#ABLE

Product Construction:
Conductor:
s 
!7'THROUGH-#-FULLYANNEALED
stranded bare copper
Insulation:
s 0
REMIUM GRADEŽ#%0$-
Cable Reinforcement:
TYPE W 2000 VOLT (UL) AND TYPE RHH/RHW 600 VOLT (UL) s !
NOPENPOLYESTERBRAIDREINFORCEMENTIS
applied between the insulation and jacket
NOMINAL NOMINAL INS. CURRENT APPROX. for mechanical strength.
NO. AWG. COND. O.D. THICKNESS NOMINAL O.D. AMPS NET WT.
CATALOG OF OR COND. LBS/ Jacket:
NUMBER COND. kcmil STRAND INCHES mm INCHES mm INCHES mm (1) (2) M'(S) s 3UPER6U 4RON®Ž# "LACK
83008* 1 8 133 0.167 4.24 0.070 1.78 0.485 12.32 55 80 150 s 4
EMPERATURE2ANGE Ž#TO Ž#
s 6
OLTAGERATING
83006 1 6 259 0.210 5.33 0.070 1.78 0.565 14.35 75 105 214 600 Volt Type RHH/RHW
83004 1 4 259 0.245 6.22 0.070 1.78 0.605 15.37 95 140 277 2000 Volt Type W
83002 1 2 259 0.334 8.48 0.070 1.78 0.680 17.27 130 190 387
Jacket Marking:
83001 1 1 259 0.375 9.53 0.090 2.29 0.765 19.43 150 220 485
s 
 !7'ˆ#!2/,350%2
83010 1 1/0† 259 0.385 9.78 0.090 2.29 0.810 20.57 170 260 563 VU-TRON TYPE W PORTABLE POWER
83020 1 2/0† 259 0.475 12.07 0.090 2.29 0.885 22.48 195 300 679 CABLE (UL) DRY 90C WET 75C 2000V
83030 1 3/0† 259 0.480 12.19 0.090 2.29 0.930 23.62 225 350 809 SUNLIGHT RESISTANT P-7K-123049-
83040 1 4/0† 259 0.570 14.48 0.090 2.29 0.980 24.89 260 405 973 MSHA (SIZE) TYPE RHH OR RHW (UL)
600V
83250 1 250† 627 0.615 15.62 0.105 2.67 1.045 26.54 290 455 1155
s 
!7' +#-),ˆ#!2/,
83350 1 350† 855 0.725 18.42 0.105 2.67 1.145 29.08 350 570 1492 SUPER VU-TRON TYPE W PORTABLE
83500 1 500† 1235 0.880 22.35 0.105 2.67 1.310 33.27 430 700 2048 POWER CABLE (UL) DRY 90C WET 75C
(1)
Ampacities based on 90°C Conductor and 30°C Ambient temperature based on Table 310-16 in the National
2000V SUNLIGHT RESISTANT P-7K-
Electrical Code® for RHH/RHW with not more than three current-carrying conductors in raceway, cable or earth. 123049-MSHA (SIZE) TYPE RHH OR
(2)
Ampacities based on 90°C Conductor and 30°C Ambient temperature based on Table 310-17 and Table 400.5(B) in RHW (UL) 600V FOR CT USE---CSA
the National Electrical Code® for single-conductor cables. TYPE W (-40C) FT-5
(S)
Actual shipping weight may vary.
† Designated for CT use. Applications:
s 0ORTABLEPOWERSYSTEMS
s %
NTERTAINMENTINDUSTRYACTIVITIESSUCHAS
theatre, television, night clubs, motion
pictures, mobile communication vans,
spotlights and sound systems
s /
THERSIMILARAPPLICATIONSTHATWOULD
require permanent or temporary power
s 0
ERMANENTWIRINGOF6OLTPOWER
supplies, hoists, cranes and other
applications where flexible power leads
must be installed in conduit or raceways
Features:
s 7ATER RESISTANT
s 3
UNLIGHT RESISTANT
s $
ESIGNEDTOWITHSTANDSEVERE
environmental conditions
s 7
ITHSTANDSEXPOSURETOOIL ACIDS
alkalies, heat, flame, moisture and
chemicals
s -
EETSOREXCEEDSFLAMETEST
requirements of MSHA and UL
Industry Approvals:
s )#%!3  .%-!7# 
s 5
,4YPE7
s 5
,4YPE2((OR2(7
s -
3(!!PPROVED
s 2O(3#OMPLIANT
Packaging:
s ,
ENGTHSCUTTOORDER

27
Industrial Cord Cord & Cordset

Super Vu-Tron® Multi-Conductor Type W Round


Ž#5, 4YPE76OLT0ORTABLE0OWER#ABLE

Product Construction:
Conductor:
s !7'THROUGH-#-FULLYANNEALED
stranded bare copper
Insulation:
s 0REMIUM GRADE COLOR CODEDŽ#%0$-
s # OLOR#ODE3EECHARTBELOW
Jacket:
s 3UPER6U 4RON®Ž# "LACK
NOMINAL NOMINAL INS.
s 4
EMPERATURE2ANGE Ž#TO Ž# AWG. COND. O.D. THICKNESS NOMINAL O.D. APPROX.
CATALOG NO. OF OR COND. CURRENT NET WT.
Jacket Marking: NUMBER COND. MCM STRAND INCHES mm INCHES mm INCHES mm AMPS LBS/M'(S)
(1)
s 3):%33-!,,%24(!. vn#!2/,
SUPER VU-TRON (SIZE) TYPE W PORTABLE
2 CONDUCTOR – TYPE W – 2000 VOLT
POWER CABLE (UL) 2000V DRY 90C WET 75C 81312 2 8 133 0.167 4.24 0.060 1.52 0.770 19.56 74 334
SUN RES CSA (-40C) FT-5 P-7K-123049 MSHA 81622 2 6 259 0.210 5.33 0.060 1.52 0.910 23.11 99 483
s 3):%3 v!.$,!2'%2n3):% 490% 81642 2 4 259 0.245 6.22 0.060 1.52 1.020 25.91 130 664
W CAROL SUPER VU-TRON 90C DRY AND 81662 2 2 259 0.334 8.48 0.080 2.03 1.210 30.73 174 981
WATER RESISTANT 75C 2000V SUN RES (UL) 81372* 2 1 259 0.375 9.53 0.080 2.03 1.440 36.58 202 1490
P-7K-123049 MSHA LR27161 81382* 2 1/0 259 0.385 9.78 0.080 2.03 1.435 36.45 234 1625
Applications: 81392* 2 2/0 259 0.475 12.07 0.080 2.03 1.650 41.92 271 1880
s )NDUSTRIALANDLIGHT TOMEDIUM DUTY 81402* 2 3/0 259 0.530 13.46 0.080 2.03 1.770 44.96 313 2420
mining applications 81412* 2 4/0 259 0.570 14.48 0.080 2.03 1.920 48.77 361 2940
s (EAVY DUTYSERVICEASPOWERSUPPLYCABLE 3 CONDUCTOR – TYPE W – 2000 VOLT
s !#SYSTEMSGROUNDEDANDUNGROUNDED 81313 3 8 133 0.167 4.24 0.060 1.52 0.925 23.50 74 490
s -OBILEANDPORTABLEELECTRICALEQUIPMENT
81623 3 6 259 0.210 5.33 0.060 1.52 1.010 25.65 99 650
s -OTORANDBATTERYLEADS
s  CONDUCTORCABLESˆUSEON$#OR!# 81643 3 4 259 0.245 6.22 0.060 1.52 1.095 27.81 130 835
single-phase systems where grounding is 81663 3 2 259 0.334 8.48 0.080 2.03 1.325 33.66 174 1233
not required 81373* 3 1 259 0.375 9.53 0.080 2.03 1.500 38.10 202 1810
s  CONDUCTORCABLESˆUSEON!#SYSTEMS 81383 3 1/0 259 0.385 9.78 0.080 2.03 1.610 40.89 234 2142
where no grounding is required, or on DC 81393 3 2/0 259 0.475 12.07 0.080 2.03 1.720 43.69 271 2586
systems with one conductor for grounding 81403* 3 3/0 259 0.480 12.19 0.080 2.03 1.880 47.75 313 3381
s  CONDUCTORCABLESˆUSEONTWO ORTHREE 81413* 3 4/0 259 0.570 14.48 0.080 2.03 1.935 49.15 361 3492
phase AC systems with one conductor 81423* 3 250 627 0.615 15.62 0.095 2.41 2.390 60.71 402 5070
used for grounding
s  CONDUCTORCABLESˆUSEINAPPLICATIONS
81443* 3 350 855 0.725 18.42 0.095 2.41 2.680 68.07 495 6570
where separating the system neutral from 81473* 3 500 1235 0.880 22.35 0.095 2.41 3.030 76.96 613 8700
the frame ground is required 4 CONDUCTOR – TYPE W – 2000 VOLT
Features: 81314 4 8 133 0.167 4.24 0.060 1.52 0.985 25.02 65 595
s 7ITHSTANDSSEVEREENVIRONMENTALCONDITIONS
81624 4 6 259 0.210 5.33 0.060 1.52 1.085 27.56 87 783
s )NDENT PRINTEDFOREASYIDENTIFICATION 81644 4 4 259 0.245 6.22 0.060 1.52 1.210 30.73 114 1072
s 7ITHSTANDSEXPOSURETOOIL ACID ALKALIES 81664 4 2 259 0.334 8.48 0.080 2.03 1.435 36.45 152 1592
heat, moisture and most chemicals 81374 4 1 259 0.375 9.53 0.080 2.03 1.605 40.77 177 2051
s 2OPELAYSTRANDINGFORMAXIMUMFLEXLIFE 81384 4 1/0 259 0.385 9.78 0.080 2.03 1.720 43.69 205 2742
s %XCELLENTIMPACTRESISTANCE 81394 4 2/0 259 0.475 12.07 0.080 2.03 1.925 48.90 237 3228
s #ABLECOREBOUNDFORSUPERIORFLEXIBILITY 81404 4 3/0 259 0.480 12.19 0.080 2.03 2.055 52.20 274 4048
and toughness 81414 4 4/0 259 0.570 14.48 0.080 2.03 2.145 54.48 316 4603
Industry Approvals: 5 CONDUCTOR – TYPE W – 2000 VOLT
s #3! 81315 5 8 133 0.167 4.24 0.060 1.52 1.050 26.67 52 675
s -3(!!PPROVED 81625 5 6 259 0.210 5.33 0.060 1.52 1.200 30.48 69 956
s 5,4YPE7 81645 5 4 259 0.245 6.22 0.060 1.52 1.360 34.54 91 1332
s 2O(3#OMPLIANT 81665 5 2 259 0.334 8.48 0.080 2.03 1.600 40.64 121 2021
Packaging: 81375* 5 1 259 0.375 9.53 0.080 2.03 1.925 48.90 141 2923
s ,ENGTHSCUTTOORDER 81385 5 1/0 259 0.385 9.78 0.080 2.03 2.075 52.71 164 3142
81395* 5 2/0 259 0.475 12.07 0.080 2.03 2.160 54.86 189 4067
COLOR CODE CHART 81405* 5 3/0 259 0.530 13.46 0.080 2.03 2.260 57.40 219 4900
NO. OF 81415* 5 4/0 259 0.570 14.48 0.080 2.03 2.460 62.48 252 5980
CONDUCTORS COLOR** (1)
Ampacities based on 90°C Conductor and 30°C Ambient temperature per Table 400.5(B) of the National Electrical Code®.
2 Black, White * Non-stock item; minimum quantity purchase required.
3 Black, White, Green ** Green conductor for grounding only.
(S)
Actual shipping weight may vary.
4 Black, White, Red, Green
5 Black, White, Red, Green, Orange

28
Cord & Cordset Industrial Cord

Super Vu-Tron® Type G and Type G-GC Round


Ž#5, 6OLT0ORTABLE0OWER#ABLE

Product Construction:
Conductor:
s 
!7'THROUGH-#-FULLY
annealed stranded bare copper
Insulation:
s 0
REMIUM GRADE COLOR CODED
Ž#%0$-
s #
OLOR#ODE3EECHARTBELOW
s )NSULATEDGROUNDSANDGROUND
checks
3 CONDUCTOR – TYPE G-GC – 2000 VOLT
NOMINAL COND. YELLOW GREEN NOMINAL INS. NOMINAL APPROX. Jacket:
NO. AWG. O.D. GROUND GROUND THICKNESS O.D. NET WT. s 3UPER6U 4RON®Ž# "LACK
CATALOG OF OR COND. CHECK COND. CURR. LBS/ s 4
EMPERATURE2ANGE Ž#
NUMBER COND. MCM STRAND INCHES mm AWG. SIZE AWG. SIZE INCHES mm INCHES mm AMPS (1)
M'(S) TO Ž#

82313 3 8 133 0.167 4.24 10  0.060 1.52 0.965 24.51 65 609 Jacket Marking:
s 4
90%' '#!.$3-!,,%2 n
82623 3 6 259 0.210 5.33 10  0.060 1.52 1.050 26.67 87 797 CAROL SUPER VU-TRON (SIZE)
82643 3 4 259 0.245 6.22 10  0.060 1.52 1.145 29.08 114 984 TYPE G-GC PORTABLE POWER
CABLE (UL) 2000V DRY 90C WET
82663 3 2 259 0.334 8.48 10  0.080 2.03 1.345 34.16 152 1465 75C SUN RES CSA (-40C) FT-5
P-7K-123049 MSHA
82373(2) 3 1 259 0.375 9.53 8  0.080 2.03 1.465 37.21 177 1807 s 4
90%' '#,!2'%24(!. n
82383(2) 3 1/0 259 0.385 9.78 8  0.080 2.03 1.605 40.77 205 2405 (SIZE) TYPE G-GC CAROL SUPER
VU-TRON 90C DRY AND WATER
82393 (2)
3 2/0 259 0.475 12.07 8  0.080 2.03 1.715 43.56 237 2510 RESISTANT 75C 2000V SUN
82403(2) 3 3/0 259 0.480 12.19 8  0.080 2.03 1.850 46.99 274 3773 RES (UL) P-7K-123033 MSHA
LR 27161
82413(2) 3 4/0 259 0.570 14.48 8  0.080 2.03 1.980 50.29 316 3946 s 4
90%'n#!2/,350%2
VU-TRON (SIZE) TYPE G
82423 * (2)
3 250 627 0.615 15.62 8  0.095 2.41 2.390 60.71 352 6060
PORTABLE POWER CABLE
82443(2)* 3 350 855 0.725 18.42 8  0.095 2.41 2.680 68.07 433 7400 (UL) 600/2000V DRY 90C WET
75C SUN RES CSA (-40C) FT-5
82473(2)* 3 500 1235 0.880 22.35 8  0.095 2.41 3.030 76.96 526 10100 P-7K-123049 MSHA
Applications:
4 CONDUCTOR – TYPE G – 600/2000 VOLT s )NDUSTRIALANDLIGHT TOMEDIUM
NOMINAL NOMINAL INS. duty mining applications
GREEN APPROX.
NO. AWG. COND. O.D. COND. THICKNESS NOMINAL O.D. NET WT. s ( EAVY DUTYSERVICEASPOWER
CATALOG OF OR COND. AWG. CURRENT LBS/ supply cable
NUMBER COND. MCM STRAND INCHES mm SIZE INCHES mm INCHES mm AMPS (1) M'(S) s - OBILEANDPORTABLEELECTRICAL
equipment
82314 4 8 133 0.167 4.24  0.060 1.52 1.045 26.54 52 705 s  AND CONDUCTORˆUSEON
three-phase AC systems where
82624 4 6 259 0.210 5.33  0.060 1.52 1.125 28.58 70 914 grounding is required
82644 4 4 259 0.245 6.22  0.060 1.52 1.210 30.73 91 1370 Features:
82664 4 2 259 0.334 8.48  0.080 2.03 1.435 36.45 122 1802 s %
XCELLENTIMPACTANDABRASION
resistance
82374(2)* 4 1 259 0.375 9.53  0.080 2.03 1.650 41.91 142 2479 s 7
ITHSTANDEXPOSURETOOIL
acids, alkalies, heat, moisture
82384(2) 4 1/0 259 0.385 9.78  0.080 2.03 1.720 43.69 164 3080 and most chemicals
82394(2) 4 2/0 259 0.475 12.07  0.080 2.03 1.860 47.24 190 3119 s )NDENT PRINTEDFOREASY
identification
82404(2) 4 3/0 259 0.480 12.19  0.080 2.03 2.075 52.71 219 4542 s 2 OPELAYSTRANDINGFORMAXIMUM
82414(2) 4 4/0 259 0.570 14.48  0.080 2.03 2.155 54.74 253 5078 flex life
s # ABLECOREBOUNDFORSUPERIOR
(1)
Ampacities based on 90°C Conductor and 30°C Ambient temperature per table 400.5(B) of the National Electrical Code®. flexibility and toughness
(2)
UL Listed and c(UL) certified. s . ON WICKINGRUBBERFILLERS''#
* Non-stock item; minimum quantity purchase required. s # ANADIANCOLORCODEAVAILABLE
(S)
Actual shipping weight may vary. upon request
COLOR CODE CHART Industry Approvals:
NO. OF s 5,4YPE' ' '#
CONDUCTORS COLOR s #
3!
s -
3(!!PPROVED
3 Black, White, Red s 2O(3#OMPLIANT
4 Black, White, Red, Orange Packaging:
s ,
ENGTHSCUTTOORDER

29
Industrial Cord Cord & Cordset

Super Vu-Tron® Canadian Type G and Type G-GC Round


Ž#5, 6OLT0ORTABLE0OWER#ABLE

Product Construction:
Conductor:
s !7'THROUGHFULLYANNEALED
stranded bare copper
Insulation:
s 0REMIUM GRADE COLOR CODED
Ž#%0$-
s #OLOR#ODE3EECHARTBELOW
s )NSULATEDYELLOWGROUNDCHECK
Jacket: 3 CONDUCTOR – TYPE G-GC – 2000 VOLT
s 3UPER6U 4RON®Ž# "LACK NOMINAL COND. YELLOW GREEN NOMINAL INS. NOMINAL APPROX.
s 4
EMPERATURE2ANGE Ž# NO. O.D. GROUND GROUND THICKNESS O.D. NET WT.
TO Ž# CATALOG OF AWG. COND. CHECK COND. CURR. LBS/
(1)
NUMBER COND. SIZE STRAND INCHES mm AWG. SIZE AWG. SIZE INCHES mm INCHES mm AMPS M'(S)
Jacket Marking:
s #!2/,350%265 42/.3):% 83113 3 6 259 0.210 5.33 10  0.060 1.52 1.025 26.04 87 827
TYPE G-GC 2KV 90C (-40C)
WET FT-5 CSA LR92874 83123 3 4 259 0.245 6.22 10  0.060 1.52 1.140 28.96 114 1063
P-7K-123049 MSHA 83133* 3 2 259 0.334 8.48 8  0.060 1.52 1.300 33.02 152 1590
s 490%' '#,!2'%24(!. n
(SIZE) TYPE G-GC CAROL SUPER 83143 3 1 259 0.375 9.53 8  0.080 2.03 1.495 37.97 177 1980
VU-TRON 90C DRY AND WATER
RESISTANT 75C 2000V SUN 83153 3 1/0 259 0.385 9.78 8  0.080 2.03 1.560 39.62 205 2467
RES (UL) P-7K-123033 MSHA 83163* 3 2/0 259 0.475 12.07 8  0.080 2.03 1.670 42.42 237 2480
LR 27161
s 490%'n#!2/,350%2 83183* 3 4/0 259 0.570 14.48 8  0.080 2.03 1.975 50.17 316 3744
VU-TRON (SIZE) TYPE G (1)
Ampacity rating based on CEC/CSA.
PORTABLE POWER CABLE (S)
Actual shipping weight may vary.
(UL) 600/2000V DRY 90C WET
75C SUN RES CSA (-40C) FT-5 COLOR CODE CHART
P-7K-123049 MSHA
NO. OF
Applications: CONDUCTORS COLOR
s )NDUSTRIALANDLIGHT TOMEDIUM
duty mining applications 3 Black, Red, Blue
s (EAVY DUTYSERVICEASPOWER
supply cable
s -OBILEANDPORTABLEELECTRICAL
equipment
s  AND CONDUCTORˆUSEON
three-phase AC systems where
grounding is required
Features:
s %XCELLENTIMPACTANDABRASION
resistance
s 7ITHSTANDEXPOSURETOOIL
acids, alkalies, heat, moisture
and most chemicals
s )NDENT PRINTEDFOREASY
identification
s 2OPELAYSTRANDINGFORMAXIMUM
flex life
s #ABLECOREBOUNDFORSUPERIOR
flexibility and toughness
s .ON WICKINGRUBBERFILLERS''#
s #ANADIANCOLORCODEAVAILABLE
upon request
Industry Approvals:
s 5,4YPE' ' '#
s #3!
s -3(!!PPROVED
s 2O(3#OMPLIANT
Packaging:
s ,ENGTHSCUTTOORDER

30
Cord & Cordset Industrial Cord

Carolprene® Welding Cable


Ž#6OLT

Product Construction:
Conductor:
s 
!7'THROUGH-#-FULLYANNEALED
stranded bare copper Class K
Jacket:
s 0REMIUM GRADEŽ#%0$- "LACK
s 2
EDALSOAVAILABLE
s 4
EMPERATURE2ANGE Ž#TO Ž#
CAROLPRENE® WELDING CABLE – 600 VOLT – CLASS K – 30 AWG STRANDING Jacket Marking:
NOMINAL O.D. APPROX. s #
!2/,02%.%3):% 7%,$).'#!",%
CATALOG AWG. CONDUCTOR NET WT. STD. 600 VOLT
NUMBER SIZE STRAND INCHES mm LBS/M'(S) CTN.
Applications:
01778 6 259/30 0.380 9.65 135 g s 3
ECONDARYVOLTAGERESISTANCEWELDING
leads
01777 4 374/30 0.400 10.16 172 g s 0
OWERSUPPLYAPPLICATIONSNOTEXCEEDING
01776 2 625/30 0.465 11.81 260 g 600 Volt AC
01775 1 778/30 0.495 12.57 317 g Features:
s 'OODFLEXIBILITY
01774 1/0 990/30 0.560 14.22 400 g
s !
BRASION RESISTANT
01773 2/0 1248/30 0.615 15.62 487 g s '
OODCOLORRETENTION
01772 3/0 1586/30 0.670 17.02 605 g Packaging:
01771 4/0 2054/30 0.750 19.05 827 g s 
gM gM ANDg
(304.8 m) reels
99142 250 MCM 2496/30 0.830 21.08 976 g s -
#-SIZESCUTTOLENGTH
99432 350 MCM 3432/30 0.960 24.38 1338 g s /
THERPUT UPSAVAILABLEONSPECIALORDER

99202 500 MCM 5054/30 1.200 30.48 1995 g Industry Approvals:
(S)
s 2O(3#OMPLIANT
Actual shipping weight may vary.

Suggested Ampacities:
For 600 Volt In-Line Applications
WELDING CABLE AMPACITIES AWG.
500 MCM
AMPERES
695
AWG.
1/0
AMPERES
190
SINGLE CONDUCTOR 350 MCM 552 1 160

2EQUIRED#ABLE3IZES&OR7ELDING#ABLE!PPLICATION 250 MCM 445 2 140


4/0 310 4 100
length in feet for total circuit for secondary voltages only – do not use this table for 600 Volt in-line applications
AMPS 100' 150' 200' 250' 300' 350' 400' 3/0 265 6 75
100 4 4 2 2 1 1/0 1/0 2/0 223
150 4 2 1 1/0 2/0 3/0 3/0 Ampacities for portable cable, continuous-duty
(Ambient Temperature of 40°C).
200 2 1 1/0 2/0 3/0 4/0 4/0 May not be suitable for all installations per
250 1 1/0 2/0 3/0 4/0 National Electrical Code®.

300 1/0 2/0 3/0 4/0


350 1/0 3/0 4/0
400 2/0 3/0
450 2/0 4/0
500 3/0 4/0
550 3/0 4/0
600 4/0 REQUIRED CABLE SIZES SHOWN IN AWG NUMBERS
The total circuit length includes both welding and ground leads (Based on 4-Volt drop) 60% duty cycle.
These values for current-carrying capacity are based on a copper temperature of 60°C (140°F), an ambient temperature
of 40°C (104°F) and yield load factors of from approximately 32% for the No. 2 AWG. cable to approximately 23% for
THE.O!7'CABLE ANDHIGHERFORTHESMALLERSIZES4HESIZESOFCABLESGENERALLYUSEDRANGEFROM.O!7'TO
No. 3/0 AWG. In actual service, the load factor may be much higher that indicated without overheating the cable as the
ambient temperature will generally be substantially lower than 40°C.

31
Industrial Cord Cord & Cordset

Super Vu-Tron® Welding Cable


Ž#6OLT5, #3!2((2(7

Product Construction:
Conductor:
s 6 AWG. through 4/0 AWG. fully annealed
stranded bare copper per. ASTM B-172 Class M
Jacket:
s 3UPER6U 4RON®, Orange
s 4
EMPERATURE2ANGE Ž#TO Ž#
Jacket Marking:
s !7'#!2/,350%265 42/. SUPER VU-TRON® WELDING CABLE—UL/CSA—CLASS M—34 AWG STRANDING
7%,$).'#!",%n%842!&,%8)",%5, 
6/,4 TO # /),2%3)34!.4 NOMINAL O.D. APPROX.
P-123-141 MSHA (SIZE) --- CSA 90C ARC CATALOG AWG. CONDUCTOR NET WT. STD.
WELDING CABLE FT-1 NUMBER SIZE STRAND INCHES mm LBS/M'(S) CTN.
s !7'#!2/,350%265 42/.
7%,$).'#!",%3):% %842!&,%8)",% 01768 6 660/34 0.370 9.40 125 g
5, 6/,4 TO # /),2%3)34!.4
P-123-141 MSHA --- CSA 90C ARC WELDING 01767 4 1045/34 0.415 10.54 191 g
CABLE FT-1 --- TYPE RHH OR RHW (UL) 01766 2 1666/34 0.475 12.07 259 g
600V FOR CT USE
01765 1 2090/34 0.530 13.46 331 g
Applications:
s 3ECONDARYVOLTAGERESISTANCEWELDINGLEADS 01764 1/0† 2640/34 0.575 14.61 401 g
s 0 OWERSUPPLYAPPLICATIONSNOTEXCEEDING 01763 2/0† 3300/34 0.630 16.00 511 g
Volt AC
s 3IZESANDLARGERFORPERMANENTWIRING 01762 3/0† 4180/34 0.700 17.78 615 g
in conduit or tray of 600V power supplies,
hoists, cranes or other applications where 01761 4/0† 5225/34 0.800 20.32 844 g
flexible power leads must be installed in (S)
Actual shipping weight may vary.
conduit, raceways or trays † Type RHH/RHW - 600V for CT use.

Features:
s 5,,ISTED
s #
3!#ERTIFIED
s %XCELLENTFLEXIBILITYTOLASTLONGERINFLEX
WELDING CABLE AMPACITIES
applications
s !BRASION RESISTANT
s 2ESISTSOILSANDSOLVENTS
SINGLE CONDUCTOR
s 2ATED Ž#FORUSEINCOLDENVIRONMENTS 2EQUIRED#ABLE3IZES&OR7ELDING#ABLE!PPLICATION
s 7EATHER RESISTANT
s /ZONE RESISTANT length in feet for total circuit for secondary voltages only – do not use this table for 600 Volt in-line applications
s 3AFETY COLOREDFORHIGHVISIBILITY AMPS 100' 150' 200' 250' 300' 350' 400'
s !SSUREDLONGERSERVICELIFE SAVINGMONEY 100 4 4 2 2 1 1/0 1/0
in replacement costs, maintenance cost
and downtime 150 4 2 1 1/0 2/0 3/0 3/0
s -3(!APPROVEDFORFLAMERESISTANCE 200 2 1 1/0 2/0 3/0 4/0 4/0
Industry Approvals: 250 1 1/0 2/0 3/0 4/0
s 5,,ISTED 300 1/0 2/0 3/0 4/0
s #3!#ERTIFIED 350 1/0 3/0 4/0
s -3(!!PPROVED 400 2/0 3/0
s -EETS5,6ERTICAL&LAME4ESTPER5,
450 2/0 4/0
s 2O(3#OMPLIANT
500 3/0 4/0
Packaging: 550 3/0 4/0
s gM gM ANDg
(304.8 m) reels 600 4/0 REQUIRED CABLE SIZES SHOWN IN AWG NUMBERS
s /THERPUT UPSAVAILABLEONSPECIALORDER The total circuit length includes both welding and ground leads (Based on 4-Volt drop) 60% duty cycle.
These values for current-carrying capacity are based on a copper temperature of 60°C (140°F), an ambient temperature of
Suggested Ampacities: 40°C (104°F) and yield load factors of from approximately 32% for the No. 2 AWG. cable to approximately 23% for the
For 600 Volt In-Line Applications .O!7'CABLE ANDHIGHERFORTHESMALLERSIZES4HESIZESOFCABLESGENERALLYUSEDRANGEFROM.O!7'TO
No. 3/0 AWG. In actual service, the load factor may be much higher that indicated without overheating the cable as the
ambient temperature will generally be substantially lower than 40°C.
AWG. AMPERES AWG. AMPERES
4/0 405 1 220
3/0 350 2 190
2/0 300 4 140
1/0 260 6 105
0ER3TANDARDS)#%!3  .%-!7# 0ART
Appendix J Ampacities for portable cable in accordance
with NEC Table 400.5(B).
May not be suitable for all installations per National
Electrical Code ®.

32
Cord & Cordset Industrial Cord

Super Vu-Tron® Entertainment Industry and Stage Lighting Cable


Ž#6OLT5,4YPE3#AND#3!4YPE00#

Product Construction:
Conductor:
s 
!7'THROUGH!7'FULLYANNEALED
stranded bare copper per ASTM B-172
Jacket:
s 3UPER6U 4RON® Ž# "LACK
s 4
EMPERATURE2ANGE Ž#TO Ž#

UL TYPE SC - CSA TYPE PPC - 600 VOLT


Jacket Marking:
s #
!2/,3):% 5, 6/,4490%3#
 #TO # /),2%3#-!8
NOMINAL O.D. APPROX.
CATALOG AWG. NOMINAL NET WT. CURRENT AMPS NEC TABLE 400-5 (B) FOR 90C
NUMBER SIZE STRAND INCHES mm LBS/M'(S) AMPS (1) OUTDOOR --- CSA TYPE PPC 105C
600VOLT FT5
01109* 8 168/30 0.385 9.78 110 80 Applications:
01108 6 259/30 0.430 10.92 152 105 s 0
ORTABLEPOWERSYSTEMS
s %
NTERTAINMENTINDUSTRYACTIVITIESSUCHAS
01107 4 418/30 0.475 12.07 215 140
theater, television, night clubs, motion
01106 2 646/30 0.540 13.72 296 190 pictures, mobile communication vans,
spotlights and sound systems
01105 1 836/30 0.580 14.73 360 220
s /
THERSIMILARAPPLICATIONSTHATWOULD
01104 1/0 1032/30 0.615 15.62 424 260 require temporary power
01103 2/0 1290/30 0.655 16.64 513 300 Features:
01102* 3/0 1672/30 0.720 18.29 644 350 s 7ATER RESISTANT
s 3
UNLIGHT RESISTANT
01101 4/0 2066/30 0.780 19.81 824 405 s $
ESIGNEDTOWITHSTANDSEVERE
(1)
environmental conditions
Table 400-5(B) NEC
* Non-stock item; minimum quantity purchase required.
s 7
ITHSTANDSEXPOSURETOOIL
(S)
Actual shipping weight may vary. acids, alkalies, heat, flame, moisture
and chemicals
s -
EETSOREXCEEDSFLAMETEST
requirements of MSHA, CSA and UL
s )NDENTPRINTED
Industry Approvals:
s 5
,,ISTED
s #
3!#ERTIFIED
s 2O(3#OMPLIANT
Packaging:
s ,
ENGTHSCUTTOORDER

33
Industrial Cord Cord & Cordset

Super Vu-Tron® Single Conductor Type W Extra-Flex


Ž#6OLT5,,ISTED

Product Construction:
Conductor:
s !7'THROUGH-#-FULLYANNEALED
stranded bare copper per ASTM B-172
Insulation:
s 0REMIUM GRADEŽ#%0$-
Cable Reinforcement:
s !NOPENPOLYESTERBRAIDREINFORCEMENTIS TYPE W - 2000 VOLT - UL
applied between the insulation and jacket
for mechanical strength NOMINAL NOMINAL INS.
COND. O.D. THICKNESS NOMINAL O.D. APPROX.
Jacket: CATALOG AWG. NOMINAL NET WT. CURRENT
s 3UPER6U 4RON® Ž# "LACK NUMBER OR MCM STRAND INCHES mm INCHES mm INCHES mm LBS/M'(S) AMPS (1)
s 4
EMPERATURE2ANGE Ž#TO Ž#
80611* 8 168/30 0.165 4.19 0.060 1.52 0.440 11.18 149 80
Jacket Marking:
80621* 6 260/30 0.205 1.55 0.060 1.52 0.530 13.46 205 105
s #!2/,350%265 42/.490%7
PORTABLE POWER CABLE (SIZE) 2000V 80631* 4 418/30 0.255 6.48 0.060 1.52 0.585 14.86 264 140
90C DRY AND WATER RESISTANT 75C 80641 2 625/30 0.300 7.62 0.070 1.78 0.650 16.51 370 190
SUN RES (UL) P-7K-123049-MSHA---
CSA TYPE W (-40C) FT-5 80651* 1 778/30 0.320 8.13 0.090 2.29 0.730 18.54 479 220
Applications: 80661* 1/0 1056/30 0.395 10.03 0.090 2.29 0.750 19.05 535 260
s 0ORTABLEPOWERSYSTEMS 80671* 2/0 1248/30 0.425 10.80 0.090 2.29 0.825 20.96 653 300
s % NTERTAINMENTINDUSTRYACTIVITIESSUCHAS
theater, television, night clubs, motion 80681* 3/0 1672/30 0.500 12.70 0.090 2.29 0.855 21.72 755 350
pictures, mobile communication vans, 80691 4/0 2054/30 0.550 13.97 0.090 2.29 0.980 24.89 1056 405
spotlights and sound systems
s /THERSIMILARAPPLICATIONSTHATWOULD 80701* 250 MCM 2496/30 0.625 15.88 0.105 2.67 1.000 25.40 1150 455
require temporary power (1)
Ampacities based on NEC table 400.5(B).
Features: * Non-stock item; minimum quantity purchase required.
(S)
Actual shipping weight may vary.
s 7ATER RESISTANT
s 3 UNLIGHT RESISTANT
s $ESIGNEDTOWITHSTANDSEVERE
environmental conditions
s 7ITHSTANDSEXPOSURETOOIL
acids, alkalies, heat, flame, moisture
and chemicals
s -EETSOREXCEEDSFLAMETEST
requirements of MSHA and UL
Industry Approvals:
s 5,,ISTED
s -3(!!PPROVED
s 2O(3#OMPLIANT
s #3!#ERTIFIED
Packaging:
s ,ENGTHSCUTTOORDER

34
Cord & Cordset Industrial Cord

Super Vu-Tron® EPR/CPE Diesel Locomotive Cable


Ž#6OLT$,/ 5,2((2(76OLTS#3!26OLT

Product Construction:
Conductor:
s 
!7'THROUGHKCMILSTRANDED
tinned annealed copper per AAR 589
Insulation:
s 0
REMIUM GRADEŽ#%0
Jacket:
10 AWG - 777.7 kcmil DLO - 2000 VOLT s #HLORINATED0OLYETHYLENE#0% "LACK

NOM. INS. CURRENT Jacket Marking:


AWG. APPROX.
CATALOG OR COND. THICKNESS NOMINAL O.D. AMPS NET WEIGHT s 3
):%34(2/5'(!7' #!2/,
NUMBER kcmil STRAND INCHES mm INCHES mm (1) (2) LBS/MFT(S) SUPER VU-TRON (SIZE) (STRANDING)
90C DLO 2000 VOLTS P-7K-123040
81910 10 27/24 0.045 1.14 0.26 6.60 40 55 60 MSHA CSA R90 1000V (UL) RHH OR
RHW 600 VOLTS
81908 8 37/24 0.060 1.52 0.34 8.64 55 80 95 s 3
):%34(2/5'( #!2/,
81906 6 61/24 0.060 1.52 0.40 10.16 75 105 145 SUPER VU-TRON (SIZE) 90C DLO
2000 VOLTS P-7K-123040 MSHA CSA
81904 4 105/24 0.060 1.52 0.46 11.68 95 140 205 26 # &4 n5, 2((/2
81902 2 154/24 0.060 1.52 0.52 13.21 130 190 295 RHW 600 VOLTS SUNLIGHT RESISTANT
FOR CT USE
81901 1 224/24 0.080 2.03 0.65 16.51 150 220 440 ./4%!.$-#-02).4%$
81911 1/0 280/24 0.080 2.03 0.69 17.53 170 260 515 (UL) RHH OR RHW 2000 VOLTS)
s 3
):%-#-/.,9 #!2/,350%2
81920 2/0 329/24 0.080 2.03 0.73 18.54 195 300 580 VU-TRON C(UL) TYPE RHW-2 2KV VW-1
81930 3/0 456/24 0.080 2.03 0.81 20.57 225 350 770 FOR CT USE TYPE DLO 2000V 90C
P-102 MSHA
81940 4/0 551/24 0.080 2.03 0.87 22.10 260 405 930
Applications:
81926 262.6 650/24 0.095 2.41 1.00 25.40 296 467 1130 s $
IESELELECTRICLOCOMOTIVES
81931 313.3 777/24 0.095 2.41 1.06 26.92 326 522 1295 s 4
ELECOMPOWERSUPPLY
s /
ILANDGASDRILLINGRIGS
81937 373.7 925/24 0.095 2.41 1.10 27.94 362 591 1545 s -
ININGANDEARTH MOVINGEQUIPMENT
81944 444.4 1110/24 0.095 2.41 1.23 31.24 400 652 1820 s 3
HIPYARDS
s -
OTORLEADS
81953 535.3 1332/24 0.120 3.05 1.34 34.04 445 728 2195 s 7
HEREFLEXIBLEPOWERLEADSMUSTBE
81964 646.4 1609/24 0.120 3.05 1.45 36.83 493 815 2560 installed in conduit or raceways
81977 777.7 1924/24 0.120 3.05 1.50 38.10 546 904 3050 Features:
s Ž#TEMPERATURERATING
Dimensions and weights are nominal; subject to industry tolerances.
(1)
Ampacities based on 90°C Conductor and 30°C Ambient temperature based on the National Electrical Code® for not more
s %
XCELLENTIMPACTANDABRASIONRESISTANCE
than three current-carrying conductors in raceway, cable or earth. s 2
ESISTSOILS ACIDS ALKALIES HEAT FLAME
(2)
Ampacities based on single-conductor in free air, 90°C conductor temperature and an Ambient air temperature of 30°C, in s &
LEXIBLETINNEDCOPPERSTRANDING
accordance with National Electrical Code® (NEC). s &
4UPONREQUEST
(S)
Actual shipping weight may vary.
Industry Approvals:
s 5,,ISTED
s !CCEPTEDFORLISTINGASFLAME RESISTANT
by MSHA
s #3!2
s 2O(3#OMPLIANT
Packaging:
s ,
ENGTHSCUTTOORDER

35

You might also like