Super Vu-Tron Industrial - Cord
Super Vu-Tron Industrial - Cord
Industrial Cord 4
Index Page
Super Vu-Tron®
Single Conductor Type W
and Type RHH/RHW 27
26
Cord & Cordset Industrial Cord
Product Construction:
Conductor:
s
!7' THROUGH -#- FULLY ANNEALED
stranded bare copper
Insulation:
s 0
REMIUM
GRADE # %0$-
Cable Reinforcement:
TYPE W 2000 VOLT (UL) AND TYPE RHH/RHW 600 VOLT (UL) s !
N OPEN POLYESTER BRAID REINFORCEMENT IS
applied between the insulation and jacket
NOMINAL NOMINAL INS. CURRENT APPROX. for mechanical strength.
NO. AWG. COND. O.D. THICKNESS NOMINAL O.D. AMPS NET WT.
CATALOG OF OR COND. LBS/ Jacket:
NUMBER COND. kcmil STRAND INCHES mm INCHES mm INCHES mm (1) (2) M'(S) s 3UPER 6U
4RON® # "LACK
83008* 1 8 133 0.167 4.24 0.070 1.78 0.485 12.32 55 80 150 s 4
EMPERATURE 2ANGE
# TO #
s 6
OLTAGE RATING
83006 1 6 259 0.210 5.33 0.070 1.78 0.565 14.35 75 105 214 600 Volt Type RHH/RHW
83004 1 4 259 0.245 6.22 0.070 1.78 0.605 15.37 95 140 277 2000 Volt Type W
83002 1 2 259 0.334 8.48 0.070 1.78 0.680 17.27 130 190 387
Jacket Marking:
83001 1 1 259 0.375 9.53 0.090 2.29 0.765 19.43 150 220 485
s
!7' #!2/, 350%2
83010 1 1/0† 259 0.385 9.78 0.090 2.29 0.810 20.57 170 260 563 VU-TRON TYPE W PORTABLE POWER
83020 1 2/0† 259 0.475 12.07 0.090 2.29 0.885 22.48 195 300 679 CABLE (UL) DRY 90C WET 75C 2000V
83030 1 3/0† 259 0.480 12.19 0.090 2.29 0.930 23.62 225 350 809 SUNLIGHT RESISTANT P-7K-123049-
83040 1 4/0† 259 0.570 14.48 0.090 2.29 0.980 24.89 260 405 973 MSHA (SIZE) TYPE RHH OR RHW (UL)
600V
83250 1 250† 627 0.615 15.62 0.105 2.67 1.045 26.54 290 455 1155
s
!7'
+#-), #!2/,
83350 1 350† 855 0.725 18.42 0.105 2.67 1.145 29.08 350 570 1492 SUPER VU-TRON TYPE W PORTABLE
83500 1 500† 1235 0.880 22.35 0.105 2.67 1.310 33.27 430 700 2048 POWER CABLE (UL) DRY 90C WET 75C
(1)
Ampacities based on 90°C Conductor and 30°C Ambient temperature based on Table 310-16 in the National
2000V SUNLIGHT RESISTANT P-7K-
Electrical Code® for RHH/RHW with not more than three current-carrying conductors in raceway, cable or earth. 123049-MSHA (SIZE) TYPE RHH OR
(2)
Ampacities based on 90°C Conductor and 30°C Ambient temperature based on Table 310-17 and Table 400.5(B) in RHW (UL) 600V FOR CT USE---CSA
the National Electrical Code® for single-conductor cables. TYPE W (-40C) FT-5
(S)
Actual shipping weight may vary.
† Designated for CT use. Applications:
s 0ORTABLE POWER SYSTEMS
s %
NTERTAINMENT INDUSTRY ACTIVITIES SUCH AS
theatre, television, night clubs, motion
pictures, mobile communication vans,
spotlights and sound systems
s /
THER SIMILAR APPLICATIONS THAT WOULD
require permanent or temporary power
s 0
ERMANENT WIRING OF 6OLT POWER
supplies, hoists, cranes and other
applications where flexible power leads
must be installed in conduit or raceways
Features:
s 7ATER
RESISTANT
s 3
UNLIGHT
RESISTANT
s $
ESIGNED TO WITHSTAND SEVERE
environmental conditions
s 7
ITHSTANDS EXPOSURE TO OIL ACIDS
alkalies, heat, flame, moisture and
chemicals
s -
EETS OR EXCEEDS FLAME TEST
requirements of MSHA and UL
Industry Approvals:
s )#%! 3
.%-! 7#
s 5
, 4YPE 7
s 5
, 4YPE 2(( OR 2(7
s -
3(! !PPROVED
s 2O(3 #OMPLIANT
Packaging:
s ,
ENGTHS CUT TO ORDER
27
Industrial Cord Cord & Cordset
Product Construction:
Conductor: