0% found this document useful (0 votes)
79 views5 pages

GOHN

This document provides product information for Belden's GOHN central loose tube cables with steel wire braid armor. The cables are available with 2 to 24 optical fibers in various fiber types including OM1-OM4 and ITU G.655, G.652D, G.657A1, G.657A2, and G.657B3. Key features include rodent protection from the steel wire braid, a simple and cost-effective loose tube construction, and a predicted lifetime over 30 years. Technical specifications are provided for construction, optical and mechanical characteristics, ordering information, applications and macro bending performance.

Uploaded by

Nadeem Haddad
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
79 views5 pages

GOHN

This document provides product information for Belden's GOHN central loose tube cables with steel wire braid armor. The cables are available with 2 to 24 optical fibers in various fiber types including OM1-OM4 and ITU G.655, G.652D, G.657A1, G.657A2, and G.657B3. Key features include rodent protection from the steel wire braid, a simple and cost-effective loose tube construction, and a predicted lifetime over 30 years. Technical specifications are provided for construction, optical and mechanical characteristics, ordering information, applications and macro bending performance.

Uploaded by

Nadeem Haddad
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

GOHN

Central Loose Tube Cables


Outdoor, Steel Wire Braid Armor (SWB)
A-DQ(ZN)2Y(SR)2Y
Full Rodent Protection
2015-04-23 v4.0

Ordering Information

Belden European Part Numbers

Fibre Description / count 2 4 6 8 12 16 24

62.5/125-OM1 GOHN102 GOHN104 GOHN106 GOHN108 GOHN112 GOHN116 GOHN124


50/125-OM2 BI GOHN202 GOHN204 GOHN206 GOHN208 GOHN212 GOHN216 GOHN224
50/125-OM3 BI GOHND02 GOHND04 GOHND06 GOHND08 GOHND12 GOHND16 GOHND24
50/125-OM4 BI GOHNE02 GOHNE04 GOHNE06 GOHNE08 GOHNE12 GOHNE16 GOHNE24
9/125 ITU G.655 C&D GOHN702 GOHN704 GOHN706 GOHN708 GOHN712 GOHN716 GOHN724
9/125 ITU G.652D & G.657A1 BI GOHN802 GOHN804 GOHN806 GOHN808 GOHN812 GOHN816 GOHN824
9/125 ITU G.657A2 BI GOHNF02 GOHNF04 GOHNF06 GOHNF08 GOHNF12 GOHNF16 GOHNF24
9/125 ITU G.657B3 BI GOHNI02 GOHNI04 GOHNI06 GOHNI08 GOHNI12 GOHNI16 GOHNI24

Std. plywood reel


Wooden reel Ø 1000 * 530 mm, 18 kg
(non-returnable)

Std. delivery length 2100 ± 105m

Applications

• building
For outdoor use in structured (data) wiring systems such as industrial backbone, campus backbone,
backbone (riser) and/or horizontal cabling..

• For outdoor use in networks for industrial, telecom, cable TV and/or broadcast.

• Suitable for direct burial and / or in ducts and trenches.


Features & Benefits

• High mechanical and full rodent protection provided by Steel Wire Braid (SWB).

• APredicted
simple (central tube) cable construction and consequently more cost-effective up to 24 fibres compared to multi-tube cables.
lifetime > 30 years.

Construction & Dimensions

Cable Specifications (construction in accordance with IEC 60794)

1. Primary coated optical fibres: Ø 250 ± 15 um.


2. Central tube, jelly filled (non-dripping and silicon-free) with up to 24 fibres.
Individually colour coded optical fibres:
1 – 12: red – natural – yellow – blue – green – violet – brown – black – orange - turquoise – pink and white.
13 – 24: red – natural – yellow – blue – green – violet – brown – grey – orange – turquoise – pink and white
with rings.
3. Swellable glass yarns as strength members and for the longitudinal watertightness.
4. PE inner jacket.
5. Steel Wire Braid , 0.25 mm galvanized steel wires, 60 % coverage
6. Black UV resistant PE outer jacket.
Identification: BELDEN OFC – “cable type” – number x type of fibre + date-, meter- and P/N marking.

Mechanical Data

No. of fibres Max. 24


Ø Central tube (mm) 3.3
Ø Inner jacket, nom 5.8
Ø Outer jacket, nom 10.0
Energy of flame (kJ/m) 2503
Weight (kg/km) 98

2
Optical Characteristics

Characteristics Single-Mode – Matched-Cladded optical fibres according to ITU.

Cable
European Mode-Field AttenuationB
Wave- Cut-off
P/N /Cladding typical/ Dispersion PMD
Fibre-Type length Wave-
Coding, Diameter max. (ps/(nm-km) (ps/km)
(nm) length
Position 5 (um) (dB/km)
(nm)

9/125 8.4 ± 0.6 1550 0.2 / 0.22 ≤ 4.5 A


7 < 0.04 ≤ 1260
G.655 C&D 125 ± 0.7 1625 0.21 / 0.24 ≤ 7.9

9/125
1310 0.33 / 0.34 ≤ 3.2
G.652D & 9.2 ± 0.4
8 1550 0.18 / 0.19 ≤ 17 ≤ 0.06 ≤ 1260
G.657A1 BI 125 ± 0.7
1625 0.20 / 0.24
OS2
1310 0.34 / 0.35 ≤ 3.5
9/125 8.9 ± 0.4
F 1550 0.19 / 0.21 ≤ 18 ≤ 0.2 ≤ 1260
G.657A2 BI 124.8 ± 0.3
1625 0.20 / 0.24
1310 0.34 / 0.35 ≤ 3.5
9/125 8.8 ± 0.4
I 1550 0.19 / 0.21 ≤ 18 ≤ 0.06 ≤ 1260
G.657B3 BI 125 ± 0.4
1625 0.20 / 0.23
Note A- Link design value
Note B- Due to cabling the optical attenuation values can increase with max. 0.05 dB/km

Characteristics Multi-Mode Graded-Index optical fibres according to IEC 60793

Ethernet
European Core/ AttenuationC Performance
Wave- Bandwidth (m)
Num.
P/N Fibre- Cladding typical/
length Apert.
Coding, Type Diameter max.
(nm) (MHz•km) (μm)
Position 5 (um) (dB/km)
1 10
GBE GBE
0.275
62.5/125 62.5 ± 2.5 850 2.7 / 3.0 ≥ 200 220 33
1 ±
OM1 125 ± 1 1300 0.7 / 0.8 ≥ 600 550 300
0.015
50/125 50 ± 2.5 850 2.3 / 2.5 ≥ 500 600 83 0.20 ±
2
OM2 BI 125 ± 1 1300 0.5 / 0.6 ≥ 500 600 300 0.015

50/125 50 ± 2.5 850 2.3 / 2.5 ≥ 1500 1000 300 0.20 ±


D
OM3 BI 125 ± 1 1300 0.5 / 0.6 ≥ 500 550 300 0.015

50/125 50 ± 2.5 850 2.3 / 2.5 ≥ 3500 1100 550 0.20 ±


E
OM4 BI 125 ± 1 1300 0.5 / 0.6 ≥ 500 550 300 0.015

Note C- Due to cabling the optical attenuation values can increase with max. 0.4 dB/km

3
Macro Bending Performance Fibers

Maximum attenuation increase for Bend Insensitive Single Mode fibers in dB depending on turns and radius.

Turns Turns Turn Turn Turn Turn


European 100 10 1 1 1 1
Wave-
P/N Radius Radius Radius Radius Radius Radius
Fibre-Type length
Coding, 30 mm 15 mm 16 mm 10 mm 7.5 mm 5 mm
(nm)
Position 5
(dB) (dB) (dB) (dB) (dB)) (dB)
9/125
1550 0.05 0.5
7 G.655
1625 0.05 0.5
C&D
9/125
G.652D & 1550 0.03 0.25 0.75
8
G.657A1 BI 1625 0.03 1.0 1.5
OS2

9/125 1550 0.03 0.1 0.5


F
G.657A2 BI 1625 0.1 0.2 1.0

9/125 1550 0.03 0.08 0.15


I
G.657B3 BI 1625 0.1 0.25 0.45

Maximum attenuation increase for Bend Insensitive Multi Mode fibers in dB depending on turns and radius.

Turns Turns Turns


European 100 2 2
Wave-
P/N Radius Radius Radius
Fibre-Type length
Coding, 37.5 mm 15 mm 7.5 mm
(nm)
Position 5
(dB) (dB)) (dB)
62.5/125 850 0.5
1
OM1 1300 0.5

50/125 850 0.5 0.1 0.2


2
OM2 BI 1300 0.5 0.3 0.5

50/125 850 0.5 0.1 0.2


D
OM3 BI 1300 0.5 0.3 0.5

50/125 850 0.5 0.1 0.2


E
OM4 BI 1300 0.5 0.3 0.5

4
Mechanical, Physical and/or Environmental Characteristics

Description: Tested according to: Requirement: According to Family


specification:
Storage Temperature Range IEC 60794-1-22-F1 -30 to +70 °C IEC 60794-3-10
Installation Temperature Range -5 to +50 °C
Operating Temperature Range -30 to +70 °C
Bending Radius Tube (Installation and Operation) > 25 mm
Cable Core Water Blocking IEC 60794-1-22-F5 Pass
Cable Min. Bend Radius Operation (Long Term) IEC 60794-1-21-E11 10 x Cable Diam. IEC 60794-3-10
Cable Min. Bend Radius Installation (Short Term) IEC 60794-1-21-E6 20 x Cable Diam.
Cable Max. Tensile Strength Operation (Long Term) IEC 60794-1-21-E1 420 N IEC 60794-3-10
Cable Max. Tensile Strength Installation (Short Term) 1250 N
Cable Max. Crush Resistance Operation (Long Term) 11 kN/m
IEC 60794-1-21-E3 IEC 60794-3-10
Cable Max. Crush Resistance Installation (Short Term) 22 kN/m

Safety

Testing standard
Toxicity NF X 70-100-2

Guide to installation and handling

• When laying and installing optical fibre cables it is vitally important not to exceed the specified values set for pulling
tension, bending radii and temperature. The installation methods have to be in accordance with the common standards.

• The
To ease insertion into tubes by means of compressed air or pulling wire, certified lubricants (e.g. paraffin) may be used.
use of soap or similar substances as lubricants is strictly prohibited.

• ItTheis advisable
jelly filling inside the tubes can be removed using a tissue soaked in turpentine.

• to cap the cable-ends during storage.

Options

• available
Non-standard cable constructions, colours, details and/or additional information regarding specifications are
on request.

You might also like