Bulletin 193-EF Solid-State Overload Relays
Features
Standards Compliance
IEC 60947-4
CSA C22.2 No. 14
UL 508
Certifications
CE
CSA Certified (File No. LR13908)
UL Listed (File No. E33916, Guide NKCR)
Features
Catalog Number Explanation
193 – EF 1 A KP – R F L
a b c d e
a b c d
Model Version Adjustment Range [A] Voltage
Code Description Code Description Code Description Code Description
EF Bulletin 193-EF solid-state overload relay Basic 1 A‡ 20…180 KJ 24V AC
Advanced 2 B§ 160…400 KV 36V AC
C§ 160…630 KY 48V AC
‡ Pass‐thru mounting style KD 110V AC
§ Direct (to contactor) mount style KP 120V AC
KF 230V AC
KA 240V AC
KN 400V AC
KG 415V AC
KB 440V AC
ZJ 24V DC
ZY 48V DC
Factory Modifications
Code Description
R Automatic reset
F Remote reset
L External indication
Electronic Motor Protection Relays
Mounts to Contactor Adjustment Range [A] Cat. No. Cat. No.♣
100‐D95…100‐D180∆ 20…180‡ 193-EF1AÄ 193-EF2AÄ
100‐D210…100‐D420 160…400 193-EF1BÄ 193-EF2BÄ
100‐D210…100‐D420 160…630 — 193-EF2CÄ
∆ Contactor mounting requires the use of a bus bar mounting kit (Cat. Nos. 825-MVS or 825-MVS2).
‡ 0.5…20 A can be achieved by looping the motor supply cables. (Refer to the Specifications on Test Button for Thermal Overload Protection
Pressing the test button will verify thermal tripping operation time at 6x/e without the motor being connected. The test button must be held for longer than the set trip time t6x/e.
Device Installation and Commissioning
The operating instructions enclosed with the device provide all of the information necessary to set and commission it.
Surface Mounting
193-EF_A Snap-on fixing to standard DIN Rail or screw fixing
193-EF_B Screw fixing
193-EF_C Screw fixing
Mounting position: optional.) Use cable support Cat. No. 193-HD.
♣ Device ships with the External Indication Module accessory (Cat. No. 193-LB1) included.
Ä Coil Voltage Code
The catalog number as listed is incomplete. Select a coil voltage code from the table below for completion.
Example: Cat. No. 193-EF1AÄ becomes Cat. No. 193-EF1AKP.
Voltage [V] 24 36 48 110 120 230 240 400 415 440
50/60 Hz KJ KV KY KD KP KF KA KN KG KB
DC ZJ — ZY — — — — — — —
Factory Modification Options
Description Suffix Code⋆
Automatic Reset of overload and thermistor overtemperature protection -R
Remote Reset§ -F
External Indication♣ -L
⋆ Refer to the Catalog Number explanation on Catalog Number Explanation for the proper suffix code sequence.
§ Device ships with the Remote Reset Module accessory (Cat. No. 193-RB1) included.
♣ Device ships with the External Indication Module accessory (Cat. No. 193-LB1) included.
Add-On Modules
Description Pkg. Qty. Cat. No.
External Indication Module 1 193-LB1
For front mounting on a control panel or MCC
3 m connection cable with plug
Function status indication
Trips and alarms can be reset
IP54 protection
Remote Reset Module 1 193-RB1
Trip reset from any location
Operating voltage: 24…48V AC/DC
with external burden resistor:
- 8.2 kW, 4 W — 110…230V AC/DC
- 22 kW, 10 W — 240…440V AC/DC
Mounting Materials
Description For Use With Pkg. Cat. No.
Qty.
Transparent Front Cover 193-EF1, 139-EF2 1 193-PA
Terminal Shields 100-D115 2 100-DTS110
Set of two
100‐D115…100‐D180, 193‐FE 100-DTS180
Protection class IP10 per IEC 60529 and DIN 40 050
100-D210...100-D420, 193-FE 100-DTS420
For direct-on-line, reversing, two-speed, and wye-delta/star-delta
assemblies
Cable Support 193-EF1A, 193-EF2A 6 193-HD
Set of 6
Includes terminal and fixing screws
Provides support of cable end when looping through current evaluation
ports
Terminal Lugs 100-D115 2 100-DTB110
Set of two
100‐D115, 100‐D140, 100‐D180, 100‐D115E…D180E, 193‐EC_F, 100-DTB180
Protection class IP2X per IEC 60529 and DIN 40 050 193-EE_F
100-D210...100-D420, 193-EC_G, 193-EF2C, 193-EE_G 100-DTB420
Connecting Components
Description For Use With Pkg. Quantity Cat. No.
Terminal Lugs (UL/CSA), Copper Frame 100-D115 3 100-DL110
Set of three
100-D115, 100-D140, 100-D180, 193-EC_F, 193-EE_F 100-DL180
100‐D210…100‐D420, 193‐EC_G, 193‐EE_G 100-DL420
Mounting Materials — Bus Bars
Set of 3 busbars, includes terminal and fixing screws. Suitable for use with Cat. No. 193-EF1A and 193-EF2A overload relays.
Description Pkg. Qty. Cat. No.
M8 connections 3 825-MVM
Set of three
4 x 16 x 102 mm (1/8 x 5/8 x 4-1/64 in.) (125 A max.)
Universally applicable
Weight: 230 g
M8 connections 3 825-MVM2
Set of three
4 x 20 x 117 mm (1/8 x 25/32 x 4-39/64 in.) (180 A max.)
Universally applicable
M6 lower connections 3 825-MVS
Set of three
For mounting on Bul. 100-D105 and 100-D110 contactors with conventional coil
M8 lower connections 3 825-MVS2
Set of three
For mounting on Bul. 100‐D140, 100‐D180 conventional and Bul. 100‐D105E…100‐D180E contactors with electronic coil
Labeling Materials
Uniform labeling materials for contactors, motor starting equipment, timing relays, and circuit breakers
Description Pkg. Qty.‡ Cat. No.
Label Sheet 10 100-FMS
105 self-adhesive paper labels each, 6 x 17 mm
Marking Tag Sheet 10 100-FMP
160 perforated paper labels each, 6 x 17 mm, to be used with a transparent cover
Transparent Cover 100 100-FMC
To be used with marking tag sheets
Marking Tag Adapters 100 100-FMA2
To be used with marking tag: System 1492 W
‡ Must be ordered in multiples of package quantities.
Supply Voltage Failure
In the event of a supply voltage failure, the output relay resets and the stand-by indicator goes out. The actual status is stored for 30 minutes. When the supply voltage
is restored, the output relay reverts to its original state.
Reset — Manual
The reset button resets all protection functions. Resetting from any location is possible with the 193-RB1 remote reset module.
Reset — Automatic
Automatic resetting of thermal overload and thermistor overtemperature functions is an optional feature. All other protection functions must be reset manually.
Test Button for Thermal Overload Protection
Pressing the test button will verify thermal tripping operation time at 6x/e without the motor being connected. The test button must be held for longer than the set trip
time t6x/e.
Device Installation and Commissioning
The operating instructions enclosed with the device provide all of the information necessary to set and commission it.
Surface Mounting
193-EF_A Snap-on fixing to standard DIN Rail or screw fixing
193-EF_B Screw fixing
193-EF_C Screw fixing
Mounting position: optional
Setting the Rated Current (0.5…20 A) (193EF1A and 193EF2A Requires 193HD)
The motor supply cables are looped through the current transformer twice, thereby doubling the rated motor current. The setting on the Bulletin 193-EF overload relay is
the product of:
Ie [A] x…number of loops
Recommended for Ie [A] Motor Supply Cables Cable Cross Section (Flexible Strand)
IEC [mm2] CSA, UL (AWG No.)
20…180 fed straight through 4…95 10…10 000
10…20 looped twice 2.5…25 14…10
5…10 looped 4 times 1…6 14
2.5…5 looped 8 times 0.75…2.5 14
Motor supply wire looped twice Motor supply wire looped 4 times 0.5…2.5 looped 40 times 0.5…0.75 ‡
‡ CSA, UL: for I e = 0.5…2.5 A, only factory‐assembled wound devices should be installed
Rated Voltage Motor Circuit (primary circuit of current measuring device)
IEC 947, EN 60947 [V] 1000
CSA, UL [V] 600
Control Circuit
IEC 947, EN 60947 [V] 440
CSA, UL [V] 240
Rated Control Voltage US
AC 50/60 Hz [V] 24, 36, 48, 110, 120, 230, 240, 400, 415, 440, (0.8…1.1US)
DC [V] 24, 48 (0.9…1.2 US)
Terminal Cross-section
Control circuit [mm2] 2 x 2.5
Device Protection Fuse 10 A Type gG or 16 A Type gG
Output Relay Contact Information
Contact assembly 1 N.O. and 1 N.C., galvanically separated
Rated operating voltage per UL/CSA: pilot duty 240V [V] 24 110…125 220…250 380… 440
Continuous Thermal current [A] 4
Rated AC operating current AC-15
[A] 3 3 1.2
Max. permissible switching current (cos = 0.3)
AC-15
[A] 30 30 12
Rated DC operating current (L/R = 300 ms), no protective circuit needed
DC-13
[A] 2 0.3 0.2 —
Max. rated back-up fuse current 10 A, 500V AC Type gG
Ambient temperature
Operation ‐5…+60 °C
Storage ‐50…+60 °C
Transport ‐50…+85 °C
Sensor Measurement Circuit
Measurement circuit [mm2] 0.5 1.5
Cross section
Max. lead length‡ [m] 200 600
Max. cold resistance of PTC sensor chain kW 1.5
Max. number of PTC sensors per IEC 34-11-2 6
Weights
Overload Relay
193-EF1A [g] 1 070
193-EF2A [g] 1 090
193-EF1B [g] 2 510
193-EF2B [g] 2 530
193-EF2C [g] 5 550
193-LB1 indication module [g] 160
193-RB1 Remote reset module [g] 160
196-MTM Adapter [g] 5
193-PA Front cover [g] 3
193-HD Terminal lug [g] 40
Bus bars
825-MVM [g] 230
825-MVM2 [g] 290
825-MVS [g] 280
825-MVS2 [g] 350
Approvals
CE, UL Listed, CSA, Bureau Veritas, Lloyd’s Register of Shipping, Maritime
Register of Shipping, RINA
‡ Type of wiring: insulated control leads, screened > 200 m (shield connected with 1T1)
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.