KL-D2008 (H) Using Manual
KL-D2008 (H) Using Manual
User Manual
a
Index
▲The connection between load cell and indicator must be reliable, load cell's shielding wire must be reliable
grounding. Connection inserting or pull out is not allow when indicator is under the state of power, prevent
electrostatic damage the indicator or the load cell .
▲ Indicator and load cell are static sensitive equipment,anti-static measure must be taken when using, the
welding operation or other high voltage operation on the weighing pad is prohibited , at the thunderstorm
season, the reliable avoid measures must be implemented to prevent the lightning strike the load cell and the
indicator, ensure the security of the operating personne and running of the weighing equipment and related
equipment.
▲ Can not use in the area of flammable gas or flammable vapor,also can not use in the tank weighing system
with pressure.
▲Indicator and load cell must be away from the field with strong electric and magnet,and be away from strong
corresive substance ,be away from inflammable and explosive materials.
▲Using strong solvents(such as benzene,nitro-class oil)to clean the housing is prohibited.
▲Can not inject the liquid or other conductive particle into indicator to prevent to damage and electronic
shock.
b
1 Technical parameter
1
2 Operation instructions
2.1 Start-up and automatic start-up zero setting
Connect to power supply and turn on the power switch. The indicator begins self-checking. After successful
self-checking, the indicator enters the weighing status.
During the start-up, if the zero point is off-set but still in the range preset, the indicator will automatically.
Refer to manual of calibration for the range of start-up zero setting.
2.3 Tare
D20 offers 2 types of taring.
Under the weighing status.
A: Common taring:
When the weight data is over 0 and stable, press the key【Tare】and the value displayed will be deducted
as tare weight. At this time, the indicator will display value of net weight. Tare indicating light will be on and
gross indication light will be off.
B: Preset the tare weight
Press the key 【 Preset 】 and the indicator will display 【 P***** 】 . Then input the tare weight, press
【ENTER】and indicator will display original tare weight.
Parameter or
Paremeter or Function Type
Function Code
00 General Form
01 Detail Form in Certain Date
02 Detail Form during Certain Period
03 Detail Form for Certain Vehile No.
04 Detail Form for Certain Cargo No.
1. Total detail list Form
Steps Operation Display Explanation
1 Press【Form】 Pb 00 Choose total list form
Press【Enter】 Print Begin printing the form. Back to the weighing
2
status after printing
2.Some day detail list form
Steps Operation Display Explanation
Press【Form】 Pb 00
1
2 Press【01】 Pb 01 press“01”,choose some day detail list form
3 press【ENTER】 d00.00.00 Enter date
4 press【120520】 d12.05.20 For example 2012-05-20
5 Press【Enter】 Print Begin printing the form. Back to the weighing status
4
after printing
3.Some time detail list form
Steps Operation Display Explanation
Press【Form】 Pb 00
1
2 press【02】 Pb 02 press“02”,choose some time detail list form
3 press【ENTER】 d00.00.00 Enter start date
4 press【40101】 d12.05.20 For example 2012-05-20
5 press【ENTER】 d00.00.00 Enter end date
6 press【40101】 A12.05.20 For example 2012-05-20
Press【Enter】 Print Begin printing the form. Back to the weighing status
7
after printing
4.Vehicle No. detail list form
Steps Operation Display Explanation
1 Press【Form】 Pb 00
2 press【03】 Pb 03 press“03”,choose vehicle NO. detail list form
3 press【ENTER】 o 00000 Enter Vehicle number
4 press【00123】 o 00123 Vehicle number is“00123”
Press【Enter】 Print Begin printing the form. Back to the weighing status
5
after printing
5.Cargo No. detail list form
Steps Operation Display Explanation
Press【Form】 Pb 00
1
2 press【04】 Pb 04 press“04”,choose cargo NO. detail list form
3 press【ENTER】 hn ** Enter cargo number
4 press【123】 hn 123 Cargo number is“123”
Press【Enter】 Print Begin printing the form. Back to the weighing status
5
after printing
3.6.Inquiry and clear weighing record
3.6.1 Press 【Check】to check the memory contents in the indicator by different modes. Operation method
are as follows:
Press 【Check】 under weighing status (If check encrypt is selected, the indicator will display 【S-CodE】to
ask to input the password. After the password is passed) the indicator will display 【rEAd 00】to ask to
enter the inquiry mode.
rEAd 1 Check by Date rEAd 2 Check by Vehicle No.
rEAd 3 Check by Cargo No. rEAd 6 Check/clear vehicle
No.’s tare
rEAd 11 check imperfect rEAd 12 check imperfect
record by date record by vehicle
number
Press 【Enter】after enter the inquiry mode and the indicator will prompt to enter the required conditions for
the inquiry such as date, vehicle no., cargo no., customer no., remarks no. etc. After that it will display the
required records one by one. when check the complete and uncomplete record, the newest record will be
displaied.
3.6.2. Example for Inquiry Operation:
Example:Inquiry according to the date, i.e, inquiry the complete records in certain date
Step Operation Display Explanation
1 Under Weighing Status Enter code
5
Press【Check】 S-CodE
2 press【111111】 S- - - - - - Fix code“111111”
3 PRESS【ENTER】 rEAd 00 Choose function number
4 press【1】 rEAd 01 choose number 1,check the complete record
as per date
5 PRESS【ENTER】 no 0001 Show first record
6 PRESS【ENTER/↓】 d12.05.31 show first record date
7 PRESS【ENTER/↓】 t09.58.44 show first record date
8 PRESS【ENTER/↓】 o 12345 show first record vehicle number
9 PRESS【ENTER/↓】 hn 003 show first record cargo number
10 PRESS【ENTER/↓】 A001.200 show first record gross weight
11 PRESS【ENTER/↓】 t000.200 show first record tare
12 PRESS【ENTER/↓】 A001.000 show first record net weight
13 PRESS【ENTER/↓】 no 0001 Back to first record
Note:step 5-step 12,if the current weigh record do not have【REPRINT】,it will display【Err 17】,otherwise,
clear the weigh record. If press【←】will check the latest full weigh record, press 【→】will check before
full weigh record.
Step6:if press 【 clean 】 ,if the current weigh record still do not have 【 REPRINT 】 ,it will display 【 Err
17】,otherwise will clean all weigh record for this date.
3.7 Delate operation for weighing record and vehicle number tare
Step Operation Display Explanation
1 press【CLEAN】 S-CodE Enter code
2 press【111111】 S- - - - - - Fix code“111111”
3 press【ENTER】 SurE 0 Choose function number
1.Delate all complete record and uncompleted record
2.Delate all vehicle number tare
3.Delate all uncompleted record
4 press【1】 SurE 1 Choose to delete all complete record and uncompleted
record
5 press【ENTER】 ---- Deleting….
PASS finished, return to【weighing display】
4. Information tips
4.1 normal information tips
number display Explanation
【 ------- 】 please wait, the inner part of indicator is under calculating,
1
don’t make any operation
2 【 Print 】 the data is connecting between indicator and printer.
3 【 Load 】 the first data storing between the 2 times of weighting
4 【 End 】 Operation end
5 【 PASS】 Setting changed successfully
6 【Lo bAt】 Low power, will power off
7 【 -】 Voltage is under 10.2V,please recharge in time
8 【 SAVE 】 Data saving
6
2 【Err 08】 no record under this condition
【Err 11】 storing space is full with vehicle no., please delete part or all
3
of stored tare
【Err 12】 can not print the form of record by mini printer.or POS
4
【Err 17】 Parameter setting does not meet requirements, please refer to
5
the related parameters input range
【Err 19】 Zero negative weighing or instability cannot print, do not
meet back to zero conditions don't print; Storage of input
parameter not meets the requirement; Discrepancy zeros
6
conditions; Do not conform to the skin condition: unstable
negative; no tare information when check vehicle number