DAIKIN Catalogo Generale
DAIKIN Catalogo Generale
EPCE99-09E
VRV
Specifications are subject to change without prior notice
To consult the explanation of the pictogrammes,
please open the flap of this catalogue.
Zandvoordestraat 300
B-8400 Oostende, Belgium
Internet: http://www.daikin.be AIR CONDITIONING SYSTEMS
Infrared remote control
Infrared remote control with LCD to start, stop and regulate
the air conditioner from a distance.
Wired remote control
Wired remote control to start, stop and regulate the air conditioner from a
distance.
Centralised control
Centralised control to start, stop and regulate several air conditioners
from one central point.
Auto-swing
Possibility to select automatic moving of the air discharge louvre, for
uniform air flow and temperature distribution.
Draught prevention
When starting to warm up or when the thermostat is off, the air discharge direction is set horizontally and
the fan to low speed, to prevent draught. After warming up, air discharge and fan speed are set as desired.
Auto-restart
The unit restarts automatically at the original settings after power.
Fan only
The air conditioner can be used as fan, blowing air without cooling
or heating.
Auto fan speed
Automatically selects the necessary fan speed to reach or maintain
the set temperature.
Fan speed steps
Allows to select up to the given number of fan speed.
Timer
Allows to preset the air conditioner to start/stop at a specified time.
24 Hour timer
Timer can be set to start cooling/heating anytime during a 24-hours period.
Scroll compressor
Silent, reliable Daikin compressor used in medium sized outdoor units.
Energy efficiency
Daikin air conditioners are energy efficient and economical.
Whisper quiet
Daikin indoor units are whisper quiet. Also the outdoor units are
guaranteed not to disturb the quiet of the neighbourhood.
Double thermostat function
Controls the temperature via a sensor on the air conditioner or via a sensor on
the remote control.
Air filter
Removes airborne dust particles to ensure a steady supply of clean air.
Power supply
T1 = 3~, 220V, 50Hz W1 = 3N~, 400V, 50Hz
V1 = 1~, 230V, 50Hz Y1 = 3~, 400V, 50Hz
VE = 1~, 230V, 50Hz
Measuring conditions
COOLING ONLY
1) nominal cooling capacities are based on:
indoor temperature 27°CDB/19°CWB (UAT: 19.5°CWB/FWHC: 19.4°CWB)
outdoor temperature 35°CDB
refrigerant piping length 7.5m - 8/5m VRV
level difference 0m
HEAT PUMP
1) nominal cooling capacities are based on:
F oreword
indoor temperature 27°CDB/19°CWB (UATY: 19.5°CWB)
outdoor temperature 35°CDB/24°CWB “ MIGHTY OAKS FROM LITTLE ACORNS GROW “
refrigerant piping length 7.5m - 8/5m VRV
level difference 0m In 1972, Daikin Industries Ltd, established its European headquarters
2) nominal heating capacities are based on:
in Ostend, Belgium in answer to the rapidly growing European demand
indoor temperature 20°CDB/12°CWB (UATY: 21°CDB)
outdoor temperature 7°CDB/6°CWB for high quality air conditioning. Perceived at first, simply as an
refrigerant piping length 7.5m - 8/5m VRV assembly centre for Japanese manufactured equipment, the nascent
level difference 0m
plant - occupying a mere 5,000 m2 - soon evolved into a supply base
for a Europe wide distribution network. Since those early years,
Daikin Europe has benefited from continuous investment on the part of
CHILLERS: its parent company and now enjoys a position of pre eminence among
EUWA-HD(Z) / EUWA*-KA(X) / EUWA*-LZ / EUWAC-FA: evaporator: 12°C/7°C; ambient: 35°C
the largest and best known names in European air conditioning.
EUWY-HD: evaporator: 12°C/7°C; ambient: 35°C
condenser: 40°C/45°C; ambient: 7°CDB/6°CWB The company’s record of spectacular growth in both turnover and
EUW-KX: evaporator: 12°C/7°C; condenser: 30°C/35°C (cooling); 40°C/45°C (heating) production capacity is to be envied among engineering manufacturers
EUW(H)-FA/FB: evaporator: 12.5°C/7°C; condenser: 29,5°C/35°C (cooling); 39.5°C/45°C (heating)
in general and the air conditioning sector in particular.
EUWL*-KX: evaporator: 12.5°C/7°C; condensing temperature: 40OC
Fan coils: cooling: ambient 27°CDB/19°CWB
entering water temperature 7°C Widely recognised as the most advanced air conditioning production
heating: ambient 20°CDB
entering water temperature 50°C
facility in Europe, the Ostend plant is responsible for well over 80% of
FWHC: cooling: ambient 26.7°CDB/19°CWB Daikin Europe products and occupies a site approaching 150,000 m2.
entering water temperature 7.2°C
heating: ambient 20°CDB
entering water temperature 60°C
The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value, depending on the distance and acoustic environment
(for measuring conditions: please refer to the technical databooks).
The sound power level is an absolute value indicating the “power” which a sound source generates.
For more detailed information please consult our technical databooks.
78 3
EPC99.09E•General 11/10/00 16:14 Page 6
FOREWORD 3 3. Hi-VRV
4 5
EPC99.09E•General 11/10/00 16:14 Page 8
D aikin Europe
THE PRODUCTS
Daikin Europe designs and produces an extensive range of hi tech air
conditioning equipment, including air and water cooled chillers, packaged air
conditioners, splits and multi splits, VRV and Sky Air systems for commercial,
industrial and residential comfort cooling and process applications.
Around 95% of production is exported via the company’s distribution network
to countries stretching from Scandinavia to Africa.
DAIKIN QUALITY
Daikin’s much envied quality levels, stem quite simply from the close attention
paid to design, production and testing procedures as well as post sales
support. To this end, every bought in component is carefully selected and
rigorously tested to verify its contribution to product quality and reliability.
TRAINING
The continual application of leading edge technology to air conditioning has
considerable bearing on the likely future shape and direction of the European
market and only a thorough understanding of new generation Daikin products
and systems will enable their full commercial potential to be realised. Training
has long been accepted as a cornerstone of the company’s sales development
and customer support programmes and is vital if a broader understanding of
the present and future impact of air conditioning is to be achieved.
7
A/C for residential use
1
Daikin residential air conditioning is the modern, economic
and efficient way to switch on to springtime - in the living room,
dining room, kitchen or bedroom, night and day, throughout the year.
Daikin air conditioning units are easy to install, easy to use, ultra
reliable, quiet running and come in an elegant and up to date range
of wall, floor and ceiling mounted indoor models.
9
EPC99.09E•General 11/10/00 16:14 Page 12
FT(Y)18/25(22)/35G
FT25-35GZV1NB
FT 5 steps
FT(Y)40G
WA L L M O U N T E D U N I T
FT(Y)-G FT-GZ WA L L M O U N T E D U N I T
FT45GZV1NB
10 11
EPC99.09E•General 11/10/00 16:15 Page 14
WA L L M O U N T E D
INVERTER
CONTROLLED UNIT
FTX/FTK-JA FTX/FTK-H WA L L M O U N T E D
INVERTER
CONTROLLED UNIT
(1) Units should be selected on nominal capacity. Maximum capacity is limited to peak periods. *Capacity and nominal input depend on the combinations between outdoor unit and indoor units.
12 13
(1) Units should be selected on nominal capacity. Maximum capacity is limited to peak periods.
EPC99.09E•General 11/10/00 16:15 Page 16
FV only FV : 3 steps
F(C)VY : 5 steps
F L O O R S TA N D I N G U N I T
FV(Y)/FCVY-D FVXT-G F L O O R S TA N D I N G
INVERTER
p.40 2 steps
• compact • lightweight
• suction and discharge grilles only are visible • can be fitted on either ceiling
• rear or bottom air suction or lower part of wall (e.g.
• drain pan on left or right beneath a window)
• ideal for use in hotel bedrooms • powerful mode ensures a
• the air duct between the indoor unit and quick adaptation to
discharge grille can be up to 0.5m long temperature variations
• forced ON/OFF function: energy saving and • automatic airflow director
comfort increasing feature ensures uniform airflow and
temperature distribution
Refrigerant: R-22/R-407C • Power supply: V1: 1~, 230V, 50 Hz Refrigerant: R-22 • Power supply: V1: 1~, 230V, 50 Hz
COOLING ONLY FHEB18BA7V1 FHEB25GZ7V1* COOLING ONLY FL25GV1NB FL35GV1NB FL40GV1NB FL45GV1NB
Cooling capacity kW 1.7 2.4/2.4 Cooling capacity kW 2.45 3.35/3.30 4.15 5.25
Nominal input kW 0.54 0.88/0.88 Nominal input kW 0.86 1.27 1.63 2.13(V11)/2.02(W11)
Dimensions HxWxD mm 230x652x502 Dimensions HxWxD mm 490x1,050x200
Weight kg 17 17 Weight kg 16 16 17 17
Air flow rate H/L m3/min 6.5/5.2 6.5/5.2 Air flow rate H/L m3/min 7.5/6.0 8.0/6.4 6.5/5.1 10.7/6.1
Sound pressure level H/L dB(A) 34/28 35/28 Sound pressure level H/L dB(A) 37/31 38/32 39/33 47/36
Sound power level H/L dB(A) 53/49 55/49 Sound power level H dB(A) 50 51 52 59
Outdoor unit see page 35 RE-GA7V1 RE-GA7V1 (R-22) / R-GZ7V1 (R-407C) Outdoor unit see page 35 R-DC7V11/RE-GA7V1 R-DC7V11/RE-GA7V1 R-DC7V11/RE-GA7V1 R-DC7V11/W11
HEAT PUMP FHEYB18BA7V1 FHEYB22BA7V1 HEAT PUMP FLY22GV1NB FLY35GV1NB FLY40GV1NB FLY45GV1NB
Cooling capacity kW 1.8 2.2 Cooling capacity kW 2.55/2.4 3.5/3.25 3.9 4.9
Heating capacity kW 1.85 2.5 Heating capacity kW 3.2/2.65 4.1/3.6 4.7 5.55
Nominal input cooling kW 0.62 0.88 Nominal input cooling kW 1.16/0.87 1.47/1.23 1.63 2.06
heating kW 0.58 0.82 heating kW 1.14/0.79 1.5/1.23 1.62 1.90
Dimensions HxWxD mm 230x652x502 Dimensions HxWXD mm 490x1,050x200
Weight kg 17 17 Weight kg 17 17 18 18
Air flow rate (H/L) cooling m3/min 6.5/5.2 6.5/5.2 Air flow rate (H/L) cooling m3/min 7.6/6.0 8.7/6.6 7.0/5.2 10.7/6.3
heating m3/min 6.95/5.2 6.95/5.2 heating m3/min 9.2/7.4 10.0/8.0 7.8/5.7 11.5/6.9
Sound pressure cooling dB(A) 34/28 35/28 Sound pressure cooling dB(A) 37/31 38/32 40/34 47/37
level (H/L) heating dB(A) 34/29 35/29 level (H/L) heating dB(A) 37/31 39/33 40/34 47/36
Sound power level (H) cooling/heating dB(A) 53/53 55/55 Sound power level H dB(A) 50 51 52 59
Outdoor unit see page 36 REY-GA7V1 REY-GA7V1 Outdoor unit see page 36 RY-DB7V1/REY-GA7V1 RY-DA7V1/REY-GA7V1 REY-GA7V1 RY-DB7V1
18 19
EPC99.09E•General 11/10/00 16:16 Page 22
User friendly, quiet running, ultra reliable and easy to control, Daikin
air conditioning adds that cool, fresh, relaxing “extra something” to
the indoor climate, providing the perfect platform for commercial success.
21
EPC99.09E•General 11/10/00 16:17 Page 24
optional optional FHY only heat pump optional optional FHY only heat pump
FH(Y) 35 ~125
p.43
• the ideal solution for shops, restaurants or • leaves maximum floor and wall
offices without false ceilings space for furniture, decoration
• leaves maximum floor and wall space for and fittings
furniture, decoration and fittings. • extremely quiet in operation both
• air flow distribution pattern can be adapted indoors and outdoors
to suit ceiling heights up to 3.8m without loss • automatic airflow director ensures
of capacity. uniform airflow and temperature
distribution (FHY only)
• air flow distribution for ceiling
heights up to 3.8m without loss of
capacity
Refrigerant: R-22 • Power supply: V1: 1~, 230V, 50 Hz Refrigerant: R-407C • Power supply: V1: 1~, 230V, 50 Hz
COOLING ONLY FH35FJ7V1 FH45FJ7V1 FH60FJ7V1 FH71FJ7V1 FH100FJ7V1 FH125FJ7V1 COOLING ONLY FH35GZ7V1 FH45GZ7V1 FH71GZ7V1 FH100GZ7V1 FH125GZ7V1
Cooling capacity kW 4.05 5.35 6.5 7.4 10.3 12.4 Cooling capacity kW 3.75 5.18 7.1 9.7 12.3
Nominal input kW 1.3 2.11 2.42 3.0(V1)/2.8(W1) 3.7(V1)/3.4(W1) 4.50 Nominal input kW 1.32 2.16/2.06 2.90/2.86/2.86 3.69/3.47/3.47 4.76
Dimensions HxWxD mm 188x1,100x600 188x1,300x600 238x1,300x695 238x1,590x695 Dimensions HxWxD mm 188x1,100x600 188x1,300x600 238x1,300x695 238x1,590x695
Weight kg 26 27 30 30 37 45 Weight kg 26 27 30 37 45
Air flow rate H/L m3/min 13/10 13/10 18/14 18/14 26/20 33/25 Air flow rate H/L m3/min 13/10 13/10 18/14 26/20 33/25
Sound pressure level H/L dB(A) 38/33 39/34 40/35 40/35 43/38 44/39 Sound pressure level H/L dB(A) 38/33 39/34 40/35 43/38 44/39
Sound power level H dB(A) 54 55 56 56 59 61 Sound power level H dB(A) 54 55 56 59 61
Outdoor unit see page 35 R-DC7V11 R-DC7V11/W11 R-FA7V1/W1 R-FJ7V1/W1 R-FJ7V1/W1 R-FJ7W1 Outdoor unit see page 35 R-GZ7V11 R-GZ7V11/W11 R-GZ7V1/W1/T1 R-GZ7V1/W1/T1 R-GZ7W1/T1
Refrigerant: R-22 • Power supply: V1: 1~, 230V, 50 Hz Refrigerant: R-407C • Power supply: V1: 1~, 230V, 50 Hz
HEAT PUMP FHY35FJ7V1 FHY45FJ7V1 FHY60FJ7V1 FHY71FJ7V1 FHY100FJ7V1 FHY125FJ7V1 HEAT PUMP FHY35GZ7V1 FHY45GZ7V1 FHY71GZ7V1 FHY100GZ7V1 FHY125GZ7V1
Cooling capacity kW 4.1 4.8 6.15 7.3 10.0 12.4 Cooling capacity kW 3.6 4.9 7.1 10 12.2
Heating capacity kW 4.35 5.8 7.15 8.7 11.6 15.2 Heating capacity kW 4.1 5.5 8.2 11.2 14.7
Nominal input cooling kW 1.59 2.05 2.51 3.1(V1)/3(W1) 3.9(V1)/3.7(W1) 4.6 Nominal input cooling kW 1.51 2.04 2.97(V1)/2.93(W1) 4.04(V1)/3.84(W1) 4.85
heating kW 1.42 1.94 2.4 3.1(V1)/3(W1) 3.9(V1)/3.7(W1) 4.7 heating kW 1.46 1.91 3.02(V1)/2.98(W1) 4.02(V1)/3.85(W1) 4.92
Dimensions HxWxD mm 188x1,100x600 188x1,300x600 238x1,300x695 238x1,590x695 Dimensions HxWxD mm 188x1,100x600 188x1,300x600 238x1,300x695 238x1,590x695
Weight kg 26 27 30 30 37 45 Weight kg 26 27 30 37 45
Air flow rate H/L m3/min 13/10 13/10 18/14 18/14 26/20 33/25 Air flow rate H/L m3/min 13/10 13/10 18/14 26/20 33/25
Sound pressure level H/L dB(A) 38/33 39/34 40/35 40/35 43/38 44/39 Sound pressure level H/L dB(A) 38/33 39/34 40/35 43/38 44/39
Sound power level H dB(A) 54 55 56 56 59 60 Sound power level H dB(A) 54 55 56 59 60
Outdoor unit see page 36 RY-DA7V1 RY-DB7V1/W1 RY-FA7V1 RY-FJ7V1/W1 RY-FJ7V1/W1 RY-FJ7W1 Outdoor unit see page 36 RY-EAZ7V1 RY-EAZ7V1 RY-GAZ7V1/W1 RY-GAZ7V1/W1 RY-GAZ7W1
22 23
EPC99.09E•General 11/10/00 16:17 Page 26
2 steps
4 - W AY B L O W C E I L I N G
SUSPENDED CASSETTE
FUY-FJ FH(Y)K-FJ CEILING MOUNTED
CORNER CASSETTE
24 25
EPC99.09E•General 11/10/00 16:17 Page 28
4 - W AY B L O W C E I L I N G
MOUNTED CASSETTE
FH(Y)C-BJ FH(Y)C-BZ 4 - W AY B L O W C E I L I N G
MOUNTED CASSETTE
• fits flush into each ceiling • compact and lightweight unit with
• air can be discharged in any of mimimum operating sound levels
four directions • choice of 8 air flow distribution
• possibility to shut off one or two patterns
flaps for easy installation in • air flow distribution for ceiling heights
corners up to 4.2m without loss of capacity
• air flow distribution for ceiling
heights up to 4.2m without loss of
capacity
Refrigerant: R-22 • Power supply: V1: 1~, 230V, 50 Hz Refrigerant: R-407C • Power supply: V1:1~, 230V, 50 Hz
COOLING ONLY FHC35BJV1 FHC45BJV1 FHC60BJV1 FHYC71BJV1 FHYC100BJV1 FHYC125BJV1 COOLING ONLY FHC35BZV1 FHC45BZV1 FHYC71BZV1 FHYC100BZV1 FHYC125BZV1
Cooling capacity kW 3.9 5.2 6.5 7.3 10.2 12.3 Cooling capacity kW 3.80 5.2 7.1 10.0 12.3
Nominal input kW 1.36 2.15 2.42 3.0(V1)/2.8(W1) 3.7(V1)/3.4(W1) 4.5 Nominal input kW 1.36 2.20/2.10 2.99/2.96/2.96 3.77/3.56/3.56 4.76
Dimensions (HxWxD) unit mm 230x840x840 288x840x840 Dimensions HxWxD unit mm 230x840x840 288x840x840
decor. panel mm 40x950x950 decor. panel mm 40x950x950
Weight unit kg 23 23 23 23 27 27 Weight unit kg 23 23 23 27 27
decor. panel kg 5 5 5 5 5 5 decor. panel kg 5 5 5 5 5
Air flow rate H/L m3/min 14/10 15/11 18/14 18/14 28/21 31/24 Air flow rate H/L m3/min 14/10 15/11 18/14 28/21 31/24
Sound pressure level H/L dB(A) 31/27 31/27 33/28 33/28 37/32 40/35 Sound press. level H/L dBA 31/27 31/27 33/28 37/32 40/35
Sound power level H/L dB(A) 47/43 47/43 49/44 49/44 52/47 55/50 Sound power level H/L dBA 47/43 47/43 49/44 52/47 55/50
Outdoor unit see page 35 R-DC7V11 R-DC7V11/W11 R-FA7V1/W1 R-FJ7V1/W1 R-FJ7V1/W1 R-FJ7W1 Outdoor unit see page 35 R-GZ7V11/W11 R-GZ7V11/W11 R-GZ7V1/W1/T1 R-GZ7V1/W1/T1 R-GZ7W1/T1
Refrigerant: R-22 • Power supply: V1: 1~, 230V, 50 Hz Refrigerant: R-407C • Power supply: V1:1~, 230V, 50 Hz
HEAT PUMP FHYC35BJV1 FHYC45BJV1 FHYC60BJV1 FHYC71BJV1 FHYC71BJV1 FHYC100BJV1FHYC125BJV1 HEAT PUMP FHYC35BZV1 FHYC45BZV1 FHYC71BZV1 FHYC100BZV1 FHYC125BZV1
Cooling capacity kW 3.6 4.8 6.15 7.3 8.0 10.3 12.8 Cooling capacity kW 3.60 4.9 7.1 10.0 12.2
Heating capacity kW 4.65 5.8 7.15 8.7 9.0 12.2 15.3 Heating capacity kW 4.10 5.5 8.2 11.6 14.6
Nominal input cooling kW 1.63 2.07 2.51 3.1(V1)/3(W1) 3.5 4(V1)/3.8(W1) 4.6 Nominal input cooling kW 1.51 2.04 3.0/2.96 4.11/3.89 4.89
heating kW 1.52 1.93 2.4 3.1(V1)/3(W1) 3.3 3.8(V1)/3.6(W1) 4.7 heating kW 1.46 1.91 2.97/2.93 4.03/3.86 4.99
Dimensions (HxWxD) unit mm 230x840x840 288x840x840 Dimensions (HxWxD) unit mm 230x840x840 288x840x840
decor. panel mm 40x950x950 decor. panel mm 40x950x950
Weight unit kg 23 23 23 23 23 27 27 Weight unit kg 23 23 23 27 27
decor. panel kg 5 5 5 5 5 5 5 decor. panel kg 5 5 5 5 5
Air flow rate H/L m3/min 14/10 15/11 18/14 18/14 18/14 28/21 31/24 Air flow rate H/L m3/min 14/10 15/11 18/14 28/21 31/24
Sound pressure level H/L dB(A) 31/27 31/27 33/28 33/28 33/28 37/32 40/35 Sound press. level H/L dBA 31/27 31/27 33/28 37/32 40/35
Sound power level H/L dB(A) 47/43 47/43 49/44 49/44 49/44 52/47 55/50 Sound power level H/L dBA 47/43 47/43 49/44 52/47 55/50
Outdoor unit see page 36 RY-DA7V1 RY-DB7V1/W1 RY-FA7V1 RY-FJ7V1/W1 RZY71LV1 RY-FJ7V1/W1 RY-FJ7W1 Outdoor unit see page 36 RY-EAZ7V1 RY-EAZ7V1 RY-GZ7V1/W1 RY-GZ7V1/W1 RY-GZ7W1
26 27
EPC99.09E•General 11/10/00 16:18 Page 30
FHYB FHB 35 ~ 60
35 ~125 p.40
p.43
Refrigerant: R-22 • Power supply: V1: 1~, 230V, 50 Hz Refrigerant: R-407C • Power supply: V1: 1~, 230V, 50 Hz
COOLING ONLY FHB35FK7V1 FHB45FK7V1 FHB60FK7V1 FHYB71FK7V1 FHYB100FK7V1 FHYB125FK7V1 COOLING ONLY FHB35GZ7V1 FHB45GZ7V1 FHYB71GZ7V1 FHYB100GZ7V1 FHYB125GZ7V1
Cooling capacity kW 3.95 5.3 6.5 7.2 10.5 12.4 Cooling capacity kW 3.70 4.90 7.1 10.0 12.3
Nominal input kW 1.36 2.17 3.10 3.1(V1)/2.9(W1) 3.8(V1)/3.5(W1) 4.6 Nominal input kW 1.40 2.23/2.13 2.96/2.93/2.93 3.70/3.54/3.54 4.79
Dimensions (HxWxD) unit mm 300x700x800 300x1,000x800 300x1,400x800 Dimensions (HxWxD) unit mm 300x700x800 300x1,000x800 300x1,400x800
decor. panel mm 55x880x500 55x1,100x500 55x1,500x500 decor. panel mm 55x880x500 55x1,100x500 55x1,500x500
Weight unit kg 30 31 41 41 51 52 Weight unit kg 30 31 41 51 52
decor. panel kg 3.5 3.5 4.5 4.5 6.5 6.5 decor. panel kg 3.5 3.5 4.5 6.5 6.5
Air flow rate H/L m3/min 11.5/9 14/10 17/13 19/14 27/20 35/24 Air flow rate H/L m3/min 11.5/9.0 14.0/10.0 19/14 27/20 35/24
Sound pressure level H/L dB(A) 33/29 33/29 34/30 34/30 36/31 38/32 Sound pressure level H/L dB(A) 33/29 33/29 34/30 36/31 38/32
Sound power level H dB(A) 52 53 60 60 62 63 Sound power level H dB(A) 52 53 60 62 63
Outdoor unit see page 35 R-DC7V11 R-DC7V11/W11 R-FA7V1/W1 R-FJ7V1/W1 R-FJ7V1/W1 R-FJ7W1 Outdoor unit see page 35 R-GZ7V11 R-GZ7V11/W11 R-GZ7V1/W1/T1 R-GZ7V1/W1/T1 R-GZ7W1/T1
Refrigerant: R-22 • Power supply: V1: 1~, 230V, 50 Hz Refrigerant: R-407C • Power supply: V1: 1~, 230V, 50 Hz
HEAT PUMP FHYB35FK7V1 FHYB45FK7V1 FHYB60FK7V1 FHYB71FK7V1 FHYB100FK7V1 FHYB125FK7V1 HEAT PUMP FHYB35GZ7V1 FHYB45GZ7V1 FHYB71GZ7V1 FHYB100GZ7V1 FHYB125GZ7V1
Cooling capacity kW 3.8 4.45 6.25 7.2 10.0 12.4 Cooling capacity kW 3.60 4.9 7.1 10.0 12.2
Heating capacity kW 4.2 5.60 7.40 8.6 11.6 15.2 Heating capacity kW 4.10 5.5 8.2 11.2 14.7
Nominal input cooling kW 1.64 2.15 3.09 3.2(V1)/3.1(W1) 4.1(V1)/3.9(W1) 4.7 Nominal input cooling kW 1.64 2.09 2.97/2.93 4.04/3.87 4.92
heating kW 1.45 1.96 2.74 3.2(V1)/3.1(W1) 4.1(V1)/4.1(W1) 4.8 heating kW 1.46 1.97 3.03/2.96 4.02/3.93 4.97
Dimensions (HxWxD) unit mm 300x700x800 300x1,000x800 300x1,400x800 Dimensions (HxWxD) unit mm 300x700x800 300x1,000x800 300x1,400x800
decor. panel mm 55x880x500 55x1,100x500 55x1,500x500 decor. panel mm 55x880x500 55x1,100x500 55x1,500x500
Weight unit kg 30 31 41 41 51 52 Weight unit kg 30 31 41 51 52
decor. panel kg 3.5 3.5 4.5 4.5 6.5 6.5 decor. panel kg 3.5 3.5 4.5 6.5 6.5
Air flow rate H/L m3/min 11.5/9 14/10 17/13 19/14 27/20 35/24 Air flow rate H/L m3/min 11.5/9.0 14.0/10.0 19/14 27/20 35/24
Sound pressure level H/L dB(A) 33/29 33/29 34/30 34/30 36/31 38/32 Sound pressure level H/L dB(A) 33/29 33/29 34/30 36/31 38/32
Sound power level H dB(A) 52 53 60 60 62 63 Sound power level H dB(A) 52 53 60 62 63
Outdoor unit see page 36 RY-DA7V1 RY-DB7V1 RY-FA7V1 RY-FJ7V1/W1 RY-FJ7V1/W1 RY-FJ7W1 Outdoor unit see page 36 RY-EAZ7V1 RY-EAZ7V1 RY-GZ7V1/W1 RY-GZ7V1/W1 RY-GZ7W1
28 29
EPC99.09E•General 11/10/00 16:18 Page 32
optional optional
optional optional optional heat pump
2 steps
2 steps
CONCEALED CEILING
UNIT
FHYB-F FAY-FJ WA L L M O U N T E D U N I T
HEAT PUMP FHYB71FV1 Refrigerant: R-22 • Power supply: V1: 1~, 230V, 50 Hz
Cooling capacity (1) kW 5.7-7.1-8.0
Heating capacity (1) kW 5.4-8.0-9.0 HEAT PUMP FAY71FJV1 FAY100FJV1
Nominal input (1) cooling kW 3.5 Cooling capacity kW 7.3 10.3
heating kW 3.3 Heating capacity kW 8.3 12.0
Dimensions (HxWxD) unit mm 300x1,000x800 Nominal input cooling kW 3(V1)/2.9(W1) 3.8(V1)/3.6(W1)
decor. panel mm 55x1,100x500 heating kW 3(V1)/2.9(W1) 4.1(V1)/3.9(W1)
Weight unit kg 41 Dimensions HxWxD mm 360x1,570x200 360x1,690x200
decor. panel kg 4.5 Weight kg 26 27
Air flow rate H/L m3/min 19/14 Air flow rate H/L m3/min 19/16 24/20
Sound pressure level H/L dB(A) 42/36 Sound pressure level H/L dB(A) 42/38 45/41
Sound power level H dB(A) * Sound power level H dB(A) 57 61
Outdoor unit see page 38 RZY71LV1 Outdoor unit see page 36 RY-FJ7V1/W1 RY-FJ7V1/W1
optional
option
optional
Refrigerant: R-22 • Power supply: V1: 1~, 230V, 50 Hz Refrigerant: R-22 • Power supply: Y1: 3~, 400V, 50 Hz
COOLING ONLY FDY125F7V1 FDY200F7V1 FDY250F7V1 COOLING ONLY UAT12JY1 UAT22JAY1 UAT30HY1
Cooling capacity kW 12.4 20 24.2 Cooling capacity kW 30.9 59.3 97.1
Nominal input kW 5.1 8.1 9.4 Nominal input kW 9.9 21.2 31.4
Dimensions HxWxD mm 350x1,400x662 450x1,400x900 Dimensions HxWxD mm 1,000x1,175x1,450 1,300x1,965x1,760 1,755x2,860x1,340
Weight kg 57 84 86 Weight kg 340 660 1080
Air flow rate M m3/min 45 72 90 Nominal air flow m3/min 95 200 295
Sound pressure level M dB(A) 44 45 47 Sound pressure level H/L dB(A) 72 80 79
Sound power level M dB(A) 78 83 83 Sound power level H dB(A) * * *
Outdoor unit see page 35 R-FJ7W1 R-F7W1 R-F7W1
Refrigerant: R-22 • Power supply: Y1: 3~, 400V, 50 Hz
Refrigerant: R-22 • Power supply: V1: 1~, 230V, 50 Hz
HEAT PUMP UATY06KY1 UATY08KY1 UATY09KY1 UATY10KY1 UATY15KY1 UATY18KY1 UATY21KY1
HEAT PUMP FDY125F7V1 FDY200F7V1 FDY250F7V1 Cooling capacity kW 17.7 22.0 26.4 31.4 43.9 52.7 61.6
Cooling capacity kW 12.4 19.5 25 Heating capacity kW 18.1 23.0 26.9 32.1 46.1 54.2 62.8
Heating capacity kW 13.4 23.4 27 Nominal input cooling kW 5.8 6.3 8.2 9.9 13.0 17.1 19.8
Nominal input cooling kW 5.1 7.9 9.4 heating kW 5.3 5.7 7.7 9.4 11.8 15.8 18.5
heating kW 4.5 6.8 8.1 Dimensions HxWxD mm 1,490x690x1,750 1,270x1,600x1,280 1,270x1,600x1,280 1,490x1,600x1,280 1,270x1,980x1,980 1,270x1,980x1,980 1,490x1,980x1,980
Dimensions HxWxD mm 350x1,400x662 450x1,400x900 Weight kg 230 326 329 344 650 656 686
Weight kg 57 84 86 Nominal air flow (indoor fan) m3/min 52 68 68 83 136 136 166
Air flow rate M m3/min 45 72 90 Sound pressure level H/L dB(A) 62 63 63 64 66 66 67
Sound pressure level M dB(A) 44 45 47 Sound power level H dB(A) * * * * * * *
Sound power level M dB(A) 78 83 83
* Sound power levels were not available at the time of publication.
Outdoor unit see page 36 RY-FJ7W1 RY-F7W1 RY-F7W1
32 33
EPC99.09E•General 11/10/00 16:19 Page 36
Daikin outdoor units are neat and sturdy and can be mounted easily
on a roof or terrace or simply placed against an outside wall. They are RE18-25-35-40
fitted with either rotary or scroll compressor, renowned for low noise and R25-35-45
R100/125 R200/250
high energy efficiency. R60
A special acryl precoated fin for anti-corrosion treatment on the heat R(E) PA I R A P P L I C AT I O N -
C O O L I N G O N LY
exchanger ensures greater resistance against severe weather conditions.
O utdoor units
Refrigerant: R-22 • Power supply: V1: 1~, 230V, 50 Hz / W1: 3N~, 400V, 50 Hz
Refrigerant: R-22 • Power supply: V1: 1~, 230V, 50 Hz / W1: 3N~, 400V, 50 Hz
Refrigerant: R-407C • Power supply: V1: 1~, 230V, 50 Hz / W1: 3N~, 400V, 50 Hz
35
EPC99.09E•General 11/10/00 16:19 Page 38
REY18-22-35
RY22
PA I R A P P L I C AT I O N -
H E AT P U M P
R(E)Y RK-J/RX-J/RXT-JZ PAIR APPLICATION -
INVERTER CONTROLLED
Inverter Control:
The use of integrated inverter control ensures S TA R T- U P T I M E
REDUCED BY 1/3
maximum comfort and efficiency
• Short start up cycle
Inverter control enables the required room temperature
to be achieved quicker than with non inverter units,
standard
in fact, start up time is reduced by one third. heat pump
• 30 % less power consumption system
The inverter controlled air conditioning detects changes small temperature difference
in room or outdoor conditions and adjusts the indoor
inverter heat pump system
temperature to compensate within seconds.
Rapid response reduces power consumption to 30% lower
than that of non inverter systems.
Refrigerant: R-22 • Power supply: V1: 1~, 230V, 50Hz / W1: 3N~, 400V, 50Hz • Whisper quiet
Inverter controlled air conditioners, like all Daikin systems, are extremely quiet in
HEAT PUMP R-22 REY18GA7V1 REY22GA7V1 RY22DB7V1 REY35GA7V1 RY35DA7V1 REY40GA7V1 RY45DB7V1 RY60FA7V1
Dimensions HxWxD mm 540x750x270 660x880x350 operation. Only the extraordinary pleasure of the indoor environment betrays their existence.
Weight kg 29 31 37 39 50 50 57 72 • In case of RXT40-50G the use of the PAM (Pulse Amplitude Modulation) inverter technology
Sound pressure level (H) cool./heat. dBA 44/45 44/45 44/45 48/50 46/47 46/49 47/48 54/55
results in better cooling and heating performances and lower energy consumption.
Sound power level (H) cool./heat. dBA 57/58 57/58 57/58 61/63 59/60 59/62 60/61 67/68
Operation range cooling °CDB 20~43 20~43 -5~46 20~43 -5~46 20~43 -5~46 -15~46
heating CWB -10~15.5 -10~15.5 -10~15.5 -10~15.5 -10~15.5 -10~15.5 -10~15.5 -10~15.5
Refrigerant: R-22 • Power supply: V1: 1~, 230V, 50Hz / W1: 3N~, 400V, 50Hz Refrigerant: R-22 • Power supply: V1: 1~, 230V, 50 Hz
HEAT PUMP R-22 RY71FJ7V1/W1 RY100FJ7V1/W1 RY125FJ7W1 RY200F7W1 RY250F7W1 CO/HP RK25JV1NB RK35JV1NB RX25JV1NB RX35JV1NB RXT40GV1NB RXT50GV1NB
Dimensions HxWxD mm 860x830x320 1,215x830x320 1,215x880x320 1,220x1,290x700 1,440x1,290x700 Dimensions HxWxD mm 550x695x265 550x695x265 640x685x285
Weight kg 81/78 101/96 102 170 195 Weight kg 33 35 33 35 37 37
Sound pressure level (H) cool./heat. dBA 48/50 51/53 51/53 58/59 58/59 Sound pressure level (H) cool/heat dBA 46/- 47/- 46/47 47/48 46/50 49/51
Sound power level (H) cool./heat. dBA 61 64 64 79/80 79/80 Sound power level (H) cool/heat dBA 59 60 59/60 60/61 59 62
Operation range cooling °CDB -5~46 -5~46 -5~46 0~46 0~46 Standard oper. range cooling °CDB 10~46 10~46 10~46 10~46
heating °CWB -10~15 -10~15 -10~15 -10~15 -10~15 heating °CWB - - -10~15 -15~15
Refrigerant: R-407C • Power supply: V1: 1~, 230V, 50Hz / W1: 3N~, 400V, 50Hz Refrigerant: R-407C • Power supply: V1: 1~, 230V, 50 Hz
HEAT PUMP R-407C RY35EAZ7V1 RY45EAZ7V1 RY71GZ7V1/W1 RY100GZ7V1/W1 RY125GZ7W1 HEAT PUMP RXT25JZV1NB RXT35JZV1NB
Dimensions HxWxD mm 660x880x350 660x880x350 860x830x320 1,215x830x320 1,215x880x320 Dimensions HxWxD mm 550x695x245
Weight kg 50 57 81/78 101/96 102 Weight kg 36
Sound pressure level (H) cool./heat. dBA 46/48 47/48 50/52 53/56 53/56 Sound pressure level (H) cool/heat dBA 46/48 47/49
Sound power level cool./heat. dBA 59/60 60/61 62/- 65/- 65/- Sound power level (H) cool/heat dBA 61/63 62/64
Operation range cooling °CDB -5~46 -5~46 -5~46 -5~46 -5~46 Standard oper. range cooling °CDB 10~43
heating °CWB -10~15.5 -10~15.5 -10~15 -10~15 -10~15 heating °CWB -10~15
36 37
EPC99.09E•General 11/10/00 16:19 Page 40
CONDENSING UNITS
ERC
INVERTER CONTROLLED
M U LT I M O D E L A P P L I C AT I O N - P O S S I B L E I N D O O R U N I T S
With Multi outdoor units, it is possible to connect up to 5 indoor units of different capacities MA90 MEY32
to a single outdoor unit, thereby reducing installation space and costs.
It is possible to combine different types of indoor units as well (e.g. wall mounted, ceiling mounted corner
cassette). All indoor units remain individually controllable and do not need to be installed at the same time or in
the same room. Further units can always be added at a later stage. Moreover, the energy consumption of a
MA(E)/M(E)Y M U LT I M O D E L A P P L I C AT I O N
Daikin Multi model system can be up to 20% lower than that of a separate indoor and outdoor unit combination.
Multi outdoor units are equipped with a rotary compressor, renowned for its low sound level and high energy
efficiency (multi inverter units are equipped with a horizontal scroll compressor).
Notes: Multi units are certified by Eurovent for combinations up to two indoor units.
Refrigerant: R-22/R-407C • Power supply: V1: 1~, 230V, 50 Hz / W1: 3N~, 400V, 50 Hz
MULTI MODEL APPLICATION - COOLING ONLY - R-407C 25 35 45 COOLING ONLY MAE25GA7V1 MAE32GA7V1 MA45DA7V1 MA56DB7V1/W1 MA90CK7V1/W1 MA90GZ7V11/W11
Max. nr. of indoor units 2 2 3 4 5 5
Wall mounted unit FT-GZ X X X
Maximum capacity kW 2.9 3.6 4.8 6.02 8.78 8.34
Concealed ceiling unit FHEB-GZ X
Maximum nominal input kW 0.9 1.34 1.42 1.83 3.07 2.86
Ceilling suspended unit FH-GZ X X
Dimensions HxWxD mm 540x750x270 540x750x270 660x880x350 660x880x350 865x880x350 865x880x350
4-way blow ceiling mounted cassette FHC-GZ X X
Weight kg 31 36 50 62 82 87
Concealed ceiling unit FHB-GZ X X
Sound pressure level H dBA 45 49 48 52 56 56
Sound power level dBA 58 62 61 65 67/68 67/68
Operation range standard °CDB 20~43 20~43 19.4~46 19.4~46 19.4~46 19.4~46
(ambient temperature) optional °CWB / / -15~46 -15~46 -5~46 -5~46
MULTI MODEL APPLICATION - HEAT PUMP - R-22 18 22 35 40 45 60
Wall mounted unit FTY X X X X X X
Refrigerant: R-22 • Power supply: V1: 1~, 230V, 50 Hz / W1: 3N~, 400V, 50 Hz
Concealed ceiling unit FHEYB X X
Floor standing unit FCVY X X X
Flexi type unit FLY X X X
HEAT PUMP MEY32GA7V1 MY56DA7V1 MY90CJ7V1/W1
Max. nr. of indoor units 2 3 5
Maximum capacity cooling kW 3.95 5.8 8.45
heating kW 3.8 5.95 9.43
Maximum nominal input cooling kW 1.38 2.19 3.12
MULTI MODEL APPLIC., INV. CONTROLLED - COOLING ONLY - R-22 25 35 50 60 heating kW 1.06 2.25 2.49
Wall mounted unit FTK X X X X Dimensions HxWxD mm 660x880x350 660x880x350 865x880x350
Concealed ceiling unit CDK X X X X Weight kg 50 72 96/95
Sound pressure level cooling dBA 46 46 56
H/L heating dBA 47 49 57
Sound power level cooling dBA 58 59 68
MULTI MODEL APPLIC., INV. CONTROLLED - HEAT PUMP - R-22 25 35 50 60 heating dBA 60 62 69/70
Wall mounted unit FTX X X X X Operation range cooling °CDB 20~43 -5~46 -5~46
Concealed ceiling unit CDX X X X X (ambient temperature) heating °CWB -10~15.5 -10~15.5 -7~15.5
Note: The power consumption mentioned in the table above is the TOTAL power consumption, i.e. based on the combination with FT(Y)...GV1B indoor unit(s).
40 41
EPC99.09E•General 11/10/00 16:20 Page 44
M U LT I M O D E L
A P P L I C AT I O N
INVERTER CONTROLLED
2MX/3MX/4MX/4MK
OUTDOOR UNITS FOR TWIN, TRIPLE AND
Multi model application, inverter controlled D O U B L E T W I N A P P L I C AT I O N
Wall mounted and concealed ceiling, inverter controlled units can be installed in multi model
application. Combination with non-inverter indoor units is not possible. It is possible to connect 2,3 or 4 indoor units to a single outdoor unit. The indoor units may
be of different types (e.g. ceiling mounted 4-way blow cassette, wall mounted, ...) and even
Multi inverter controlled outdoor units can be placed on top of each other*, thereby saving different capacities (e.g. 45 and 60 class).
installation space. An optional fixing plate between the 2 outdoor units is necessary.
All indoor units are operated together within the same mode (cooling or heating) from one
* 3MX68HV1NB/2MX52HV1NB units only remote control. This allows equal air distribution, even in larger, irregularly shaped rooms.
For specifications of outdoor units, see pages 35 (cooling only) and 36 (heat pump).
The total capacities (outdoor base) for simultaneous operation are the same as for the pair
applications.
example: R200 + FHY71 + FAY71 + FHYB71
= R200 + FDY200
= 20.0 kW
71 35 35
Max. nr. of indoor units 2 3 4 4 (KHR79BA7)
Maximum capacity cooling kW 3.60 ~ 5.20 ~ 5.34 3.90 ~ 6.80 ~ 7.24 4.37 ~ 8 ~ 9.13 4.33 ~ 9 ~ 9.40 100 * 100 100 * 100 *
OUTDOOR UNIT
(min.-nom.-max.) heating kW 4.56 ~ 6.10 ~ 7.80 1.20 ~ 2.47 ~ 2.81 5.83 ~ 9.6 ~ 10.63 / 100 45 45 45 60 35 71 35 35 35
Sound pressure level cooling dBA 45 47 49 49 200 100 100 71 125 71 71 71 60 60 60 45 71 71 45 45 100 45 45 45 45
(KHR102BA7) (KHR102BA7) (KHR127HA7) (KHR127HA7) (KHR127HA7) (KHR127HA7) (2xKHR79BA7+KHR102BA7)
H heating dBA 46 48 49 / 250 250 250 250
Sound power level H dBA * * * * 250 125 125 45 100 100 60 60 125 60 60 60 60
Standard oper. range cooling °CDB 21~43 21~43 10~43 10~43 (KHR102BA7) (KHR127HA7) (KHR127HA7) (2xKHR79BA7+KHR102BA7)
(ambient temperature) heating °CWB -10~15 -10~15 -10~15 / Note 1 : Possible indoor types R-22: FHYC35-125 - FUY71-125 - FHYK35-71 - FAY71/100 - FHY35-60 - FHY71-125 - FH71-125 - FHYB35-125 - FDY125
Note 2 : Combinations marked with * are also available with the ozone-friendly refrigerant R-407C. Possible indoor types are FHYC - FHY - FHYB 35-71.
42 * Sound power levels were not available at the time of publication. Replace refnet kits with KHRP79BA7 and KHRP86HA7. 43
Note 3 : Between brackets the required refnet kits are mentioned necessary to install the combination.
EPC99.09E•General 11/10/00 16:20 Page 46
Hi-VRV
3
Rising energy and general building services running costs have led end users
to expect far more than just cooling and heating from their air conditioning.
A truly complete and acceptable system therefore, must be energy efficient,
economic to run, easy to install, flexible, reliable and user friendly.
Fresh air must also be supplied without increasing energy consumption
and central management and control facilities have gained in importance,
Air Conditioning
VRV
HRV DACMS
Ventilation Management
45
EPC99.09E•General 11/10/00 16:21 Page 48
VA R I A B L E R E F R I G E R A N T V O L U M E
VRV
The VRV system is available in inverter driven cooling only, heat pump and heat recovery format, each Modular design enables Daikin VRV outdoor units
designed to provide efficient and flexible comfort cooling and/or heating in a wide range of public and to be joined together in rows with an outstanding
private commercial premises. degree of uniformity. The design of the outdoor
units is sufficiently compact to allow them to be
An electronic expansion valve continually adjusts the flow of refrigerant to respond to the load requirements taken up to the top of a building in a commercial
of the indoor units, enabling the system to maintain temperatures at a virtually constant and comfortable elevator, overcoming site transportation problems.
level without the fluctuations typical of ON/OFF control systems.
The ability to control each conditioned zone keeps VRV system running costs to an absolute minimum.
Furthermore, only those areas calling for air conditioning need to be cooled or
heated and the system can be shut down
completely in unoccupied rooms.
Refrigerant: R-407C • Power supply: W1: 3N~, 400V, 50 Hz Refrigerant: R-22/R-407C • Power supply: Y1:3~, 400V, 50 Hz
INVERTER HP/CO R-407C RSXYP5K7W1 RSXYP8K7W1 RSXYP10K7W1 RSXP5K7W1 RSXP8K7W1 RSXP10K7W1 HEAT RECOVERY R-22/R-407C RSEY8KLY1 RSEY10KLY1 RSEYP8KJY1 RSEYP10KJY1
Cooling capacity kW 14.0 22.4 28.0 14.0 22.4 28.0 Cooling capacity kW 22.4 28.0 22.4 28.0
Heating capacity kW 16.0 25.0 31.5 - - - Heating capacity kW 25.0 31.5 25.0 31.5
Nominal input cooling kW 6.10 9.43 11.8 6.10 9.43 11.8 Nominal input cooling kW 9.43 11.8 9.43 11.8
heating kW 5.67 8.66 11.0 - - - heating kW 8.48 10.5 8.66 11.0
Dimensions HxWxD mm 1,440x635x690 1,220x1,280x690 1,440x1,280x690 1,440x635x690 1,220x1,280x690 1,440x1,280x690 Dimensions HxWxD mm 1,220x1,280x690 1,440x1,280x690 1,220x1,280x690 1,440x1,280x690
Weight kg 137 227 248 137 227 248 Weight kg 250 275 247 273
Air flow rate m3/min 80 150 170 80 150 170 Air flow rate m3/min 150 170 150 170
Sound pressure level (380V) dBA 54 57 58 54 57 58 Sound pressure level (380V) dBA 57 57 57 57
Operation range cooling °CDB -5 ~ 43 -5 ~ 43 Operation range cooling °CDB -5 ~ 43 -5 ~ 43 -5 ~ 43 -5 ~ 43
heating °CWB -15 ~ 15.5 - heating °CWB -15 ~ 15.5 -15 ~ 15.5 -15 ~ 15.5 -15 ~ 15.5
46 47
EPC99.09E•General 11/10/00 16:21 Page 50
Refrigerant: R-22 • Power supply: W1: 3N~,400V, 50 Hz Power supply: V1: 1~, 230V, 50 Hz
Inverter type Constant speed type Function unit
VRV PLUS USING R-22 RXY8K7W1 RXY10K7W1 RNY8K7W1 RNY10K7W1 BR2KV1/BL2KV1 BR3KV1/BL3KV1
Cooling capacity kW 21.9 27.4 21.9 27.4 - -
main unit
Heating capacity kW 21.9 27.4 21.9 27.4 - -
Dimensions HxWxD mm 1,220x1,280x690 1,440x1,280x690 1,220x1,280x690 1,440x1,280x690 1,280x400x690 1,280x500x690
sub unit RSXYP28KJY1
Weight kg 220 240 220 240 80/64 96/76
Sound pressure level dBA 58 58 58 58 - -
Operation range cooling °CDB -5 ~ 43 -5 ~ 43 -5 ~ 43 -5 ~ 43 -5 ~ 43 -5 ~ 43
heating °CWB -15 ~ 15.5 -15 ~ 15.5 -15 ~ 15.5 -15 ~ 15.5 -15 ~ 15.5 -15 ~ 15.5
Refrigerant: R-407C • Power supply: Y1:3~, 400V, 50 Hz
Indoor units
50
(1) preliminary info for VRV Plus applications using R-407C (1) preliminary info for VRV Plus applications using R-407C
51
EPC99.09E•General 11/10/00 16:22 Page 54
FXYK-KJV1/FXYKP-KV1 25 32 40 63 25 32 40 63
Inverter CO/HP cooling capacity kW 2.8 3.6 4.5 7.1 2.8 3.6 4.5 7.1
Heat recovery heating capacity kW 3.2 4.0 5.0 8.0 3.2 4.0 5.0 8.0
VRV Plus (1) cooling capacity kW 2.7 3.4 4.4 6.8 2.8 3.6 4.5 7.1
heating capacity kW 2.7 3.4 4.4 6.8 3.2 4.0 5.0 8.0
Nominal input (1) cooling W 66 66 80 105 66 66 80 105
heating W 46 46 56 85 46 46 56 85
Dimensions (HxWxD) unit mm 215x1,110x710 215x1,310x710 215x1,110x710 215x1,310x710
decor. panel mm 70x1,240x800 70x1,440x800 70x1,240x800 70x1,440x800
Weight unit kg 31 31 31 34 31 31 31 34
decor. panel kg 8.5 8.5 8.5 9.5 8.5 8.5 8.5 9.5
Air flow rate H/L m3/min 11/9 11/9 12/9 17/14 11/9 11/9 13/10 18/15
Sound pressure level H/L dBA 39/34 39/34 40/34 42/37 38/33 38/33 42/35 42/37
(1) preliminary info for VRV Plus applications using R-407C
Refrigerant: R-22 • Power supply: V1: 1~, 50Hz, 230V/VE: 1~, 50Hz, 230V
(1) preliminary info for VRV Plus applications using R-407C (1) preliminary info for VRV Plus applications using R-407C
52 53
EPC99.09E•General 11/10/00 16:22 Page 56
FXYA-KJV1/FXYAP-KV1 25 32 40 50 63 25 32 40 50 63
Inverter CO/HP cooling capacity kW 2.8 3.6 4.5 5.6 7.1 2.8 3.6 4.5 5.6 7.1
Heat recovery heating capacity kW 3.2 4.0 5.0 6.3 8.0 3.2 4.0 5.0 6.3 8.0
VRV Plus (1) cooling capacity kW 2.7 3.4 4.4 5.5 6.8 2.8 3.6 4.5 5.6 7.1
heating capacity kW 2.7 3.4 4.4 5.5 6.8 3.2 4.0 5.0 6.3 8.0
Nominal input (1) cooling W 26 28 36 35 44 26 28 36 35 44
heating W 26 28 36 35 44 26 28 36 35 44
Dimensions HxWxD mm 360x1,050x200 360x1,250x200 360x1,050x200 360x1,250x200
Weight kg 21 24 21 24
Air flow rate H/L m3/min 7/6 8/6.5 10/8 12/10 15/12 8/6.5 9/7 11/9 13/11 15/12
Sound pressure level H/L dBA 34/31 35/32 40/33 41/36 45/41 35/32 37/33 41/34 43/37 45/41
Refrigerant: R-407C • Power supply: V1: 1~, 50Hz, 230V FXYH(P) ceiling suspended unit
FXYSP-KA7V1 20 25 32 40 50 63 80 100 125 Refrigerant: R-22/R-407C •Power supply: V1: 1~, 50Hz, 230V
Inverter CO/HP cooling capacity kW 2.2 2.8 3.6 4.5 5.6 7.1 9.0 11.2 14.0
Heat recovery heating capacity kW 2.5 3.2 4.0 5.0 6.3 8.0 10.0 12.5 16.0 FXYH-K7V1/FXYHP-K7V1 32 63 100 32 63 100
VRV Plus (1) cooling capacity kW 2.2 2.8 3.6 4.5 5.6 7.1 9.0 11.2 14.0 Inverter CO/HP cooling capacity kW 3.6 7.1 11.2 3.6 7.1 11.2
heating capacity kW 2.5 3.2 4.0 5.0 6.3 8.0 10.0 12.5 16.0 Heat recovery heating capacity kW 4.0 8.0 12.5 4.0 8.0 12.5
Nominal input (1) cooling W 110 110 114 127 143 189 216 246 321 VRV Plus (1) cooling capacity kW 3.4 6.8 10.9 3.6 7.1 11.2
heating W 90 90 94 107 123 169 196 226 301 heating capacity kW 3.4 6.8 10.9 4.0 8.0 12.5
Dimensions (HxWxD) unit mm 300x550x800 300x700x800 300x1,000x800 300x1,400x800 Nominal input (1) cooling W 101 114 190 101 114 190
decor. panel mm 55x650x500 55x800x500 55x1,100x500 55x1,500x500 heating W 101 114 190 101 114 190
Weight unit kg 30 30 30 30 31 41 51 51 52 Dimensions HxWxD mm 188x1,100x600 188x1,300x600 238x1,300x695 188x1,100x600 188x1,300x600 238x1,300x695
decor. panel kg 3 3 3 3.5 3.5 4.5 6.5 6.5 6.5 Weight kg 27 31 38 27 31 38
Air flow rate H/L m3/min 9/6.5 9/6.5 9.5/7 11.5/9 15/11 21/15.5 27/20 28/20.5 38/28 Air flow rate H/L m3/min 13/10 18/14 26/20 13/10 19/15 27/21
Sound pressure level H/L dBA 32/28 32/28 33/28 33/29 35/31 35/30 37/31 38/33 40/35 Sound pressure level H/L dBA 38/33 40/35 43/38 38/33 42/37 45/40
Sound power level dBA 50 50 51 56 58 56 55 56 65 Sound power level dBA - - - 56 61 63
(1) preliminary info for VRV Plus applications using R-407C (1) preliminary info for VRV Plus applications using R-407C
54 55
EPC99.09E•General 11/10/00 16:22 Page 58
Refrigerant: R-22/R-407C • Power supply: VE: 1~, 50Hz, 230V/V1: 1~, 50Hz, 230V
FXYLM-KJVE/FXYLMP-KV1 20 25 32 40 50 63
Inverter CO/HP cooling capacity kW 2.2 2.8 3.6 4.5 5.6 7.1
New
Heat recovery heating capacity kW 2.5 3.2 4.0 5.0 6.3 8.0
VRV Plus (1) cooling capacity kW 2.2/2.2 2.7/2.8 3.4/3.6 4.4/4.5 5.5/5.6 6.8/7.1
R-22/R-407C heating capacity kW 2.2/2.5 2.7/3.2 3.4/4.0 4.4/5.0 5.5/6.3 6.8/8.0
Nominal input (1) cooling W 49 49 90 90 110 110
heating W 49 49 90 90 110 110
Dimensions HxWxD mm 610x930x220 610x1,070x220 610x1,350x220
Weight kg 19 19 23 23 27 27
Air flow rate
Sound pressure level
H/L
H/L (220V)
m3/min
dBA
7/6
35/32
7/6
35/32
8/6
35/32
11/8.5
38/33
14/11
39/34
16/12
40/35 HRV H E AT R E C O V E RY
V E N T I L AT I O N
(1) preliminary info for VRV Plus applications using R-407C
FXYL(P) floor standing unit The Daikin heat recovery ventilation system modulates the temperature and humidity of
Refrigerant: R-22 • Power supply: VE: 1~, 50Hz, 230V incoming fresh air to match indoor conditions.
A balance is thus achieved between indoor and outdoor ambients, enabling the cooling or
FXYL-KJVE 20 25 32 40 50 63 heating load placed on the air conditioning system to be reduced significantly.
Inverter CO/HP cooling capacity kW 2.2 2.8 3.6 4.5 5.6 7.1
Heat recovery heating capacity kW 2.5 3.2 4.0 5.0 6.3 8.0 HRV units can be controlled individually or integral with the air conditioning system
VRV Plus cooling capacity kW 2.2 2.7 3.4 4.4 5.5 6.8 (Daikin VRV or Sky Air series).
heating capacity kW 2.2 2.7 3.4 4.4 5.5 6.8
Nominal input cooling W 49 49 90 90 110 110
heating W 49 49 90 90 110 110
Dimensions HxWxD mm 600x1,000x222 600x1,140x222 600x1,420x222
Weight kg 25 25 30 30 36 36
Air flow rate H/L m3/min 7/6 7/6 8/6 11/8.5 14/11 16/12
Sound pressure level H/L (220V) dBA 35/32 35/32 35/32 38/33 39/34 40/35
Power supply: VE: 1~, 50Hz, 230V
Refrigerant: R-407C • Power supply: V1: 1~, 50Hz, 230V
VAM-FJVE 150 250 350 500 650 800 1000 1500 2000
FXYLP-KV1 20 25 32 40 50 63 Air flow rate m3/h 150 250 350 500 650 800 1,000 1,500 2,000
Inverter CO/HP cooling capacity kW 2.2 2.8 3.6 4.5 5.6 7.1 Sound pressure level (max.) (1) dBA 27/28.5 28/29 32/34 33/34.5 34.5/35.5 36/37 36/37 39.5/41.5 40/42.5
Heat recovery heating capacity kW 2.5 3.2 4.0 5.0 6.3 8.0 External static pressure (max.) Pa 69 64 98 98 93 137 157 137 137
VRV Plus (1) cooling capacity kW 2.2 2.8 3.6 4.5 5.6 7.1 Temperature exchange efficiency % 74 72 75 74 74 74 75 75 75
heating capacity kW 2.5 3.2 4.0 5.0 6.3 8.0 Enthalpy exchange efficiency (%) cooling 58 58 61 58 58 60 61 61 61
Nominal input (1) cooling W 49 49 90 90 110 110 heating 64 64 65 62 63 65 66 66 66
heating W 49 49 90 90 110 110 Dimensions H mm 269 269 285 285 348 348 348 710 710
Dimensions HxWxD mm 600x1,000x222 600x1,140x222 600x1,420x222 W mm 760 760 812 812 988 988 988 1,498 1,498
Weight kg 25 25 30 30 36 36 D mm 509 509 800 800 852 852 1,140 852 1,140
Air flow rate H/L m3/min 7/6 7/6 8/6 11/8.5 14/11 16/12 Weight kg 24 24 33 33 48 48 61 132 158
Sound pressure level H/L (220V) dBA 35/32 35/32 35/32 38/33 39/34 40/35 Duct diameter mm Ø 100 Ø 150 Ø 150 Ø 200 Ø 200 Ø 250 Ø 250 Ø 350 Ø 350
(1) preliminary info for VRV Plus applications using R-407C (1) Sound pressure level is measured in heat exchange mode.
56 57
EPC99.09E•General 11/10/00 16:23 Page 60
DACMS is a centralized control and management system for medium and large sized
buildings. Designed for use with Windows95®, Windows98® and WindowsNT® it offers New
precise control of VRV systems and associated heat recovery ventilation units, fans and even
lighting, from a personal computer and can monitor up to 1,024 indoor units from a single PC.
DACMS can be integrated into a general building management system, both to control A simple to use, Daikin Hi-VRV air conditioning computerised selection programme,
the air conditioning (monitoring energy consumption, indoor temperatures etc) and also to designed for use with Windows95®, Windows98® and WindowsNT® systems, enables
provide a wide range of custom designed management and service functions. consulting engineers, design and build contractors, property developers and architects etc.
It can, for example, be used to limit energy consumption, indicate filter replacement needs to plan a Daikin air conditioning project on a step by step basis, complete with detailed
or calculate optimum start up periods. drawings, bills of quantities and costs.
The programme thus enables VRV air conditioning systems to be engineered precisely
Windows95®, Windows98® and WindowsNT® are registered trademarks of Microsoft corporation. and economically (without oversizing units), thereby ensuring optimum operating cycles
and maximum energy efficiency.
58 59
EPC99.09E•General 11/10/00 16:23 Page 62
H ydronic systems
4
Precise environmental control is vital in many industrial and
commercial applications. Daikin offers an outstanding range of
powerful air cooled, water cooled and condenserless chiller systems
that will maintain ideal conditions in even the largest premises.
Daikin water chillers are of advanced design, compact and easy to
install and maintain.
61
EPC99.09E•General 11/10/00 16:23 Page 64
CHILLERS
EUWA/Y EUWA-HZ CHILLERS
air cooled air cooled
• low operating sound level
• low energy consumption
• extremely compact
• Daikin scroll compressor
• electronic controller
• wide operating range • optimised for use with R-407C
• easy to install and maintain • special Daikin R-407C scroll
• anti-corrosion treated plate type heat exchangers compressors
• available in cooling only (EUWA) and heat pump • high energy efficiency ratio
format (EUWY) • low pressure drops
• low sound level
• low direct on line start up current
• small footprint
• standard operating range from
-5°C to 43°C ambient temperature
Refrigerant : R-22 • Power supply: W1 = 3N~, 50Hz, 400V; T1 = 3~, 50Hz, 230V.
Refrigerant : R-407C • Power supply: W1 = 3N~, 50Hz, 400V; T1 = 3~, 50Hz, 230V. (except for 12HP)
COOLING ONLY EUWA5HD EUWA8HD EUWA10HD EUWA15HD EUWA20HD EUWA25HD EUWA30HD
Cooling capacity kW 10.3 18.3 21.6 30.7 43.6 52.9 65.2
Nominal input kW 4.3 6.4 8.5 13.2 17.3 21.5 26 COOLING ONLY EUWA5HDZ EUWA8HDZ EUWA10HDZ EUWA12HDZ
Dimensions HxWxD mm 1,444x645x700 1,220x1,290x700 1,444x1,290x700 1,535x1,930x700 1,535x2,575x700 1,535x3,220x700 1,535x3,865x700 Cooling capacity kW 10.1 17.7 22.7 26.5
Weight kg 135 200 230 375 510 655 780 Nominal input kW 4.2 7.2 8.5 10.6
Sound power/pressure level dB(A) 69/- 78/- 78/- 78/- 81/- 81/- 83/- Dimensions HxWxD mm 1,444x645x700 1,220x1,290x700 1,444x1,290x700 1,444x1,290x700
Weight kg 135 200 230 233
Sound power/pressure level dB(A) 69/56 78/61 78/61 78/61
Refrigerant : R-22 • Power supply: W1 = 3N~, 50Hz, 400V
Refrigerant : R-407C • Power supply: W1 = 3N~, 50Hz, 400V; T1 = 3~, 50Hz, 230V. (except for 25,35HP)
HEAT PUMP EUWY5HD EUWY8HD EUWY10HD EUWY15HD EUWY20HD EUWY25HD EUWY30HD
Cooling capacity kW 9.1 17.7 21.0 30.0 42.4 51.5 63.4
Heating capacity kW 11.9 20 25.4 36.4 50.3 62.3 75.2 COOLING ONLY EUWA15HDZ EUWA20HDZ EUWA25HDZ EUWA30HDZ EUWA35HDZ
Nominal input cooling kW 4.2 6.4 8.4 13.0 17.0 21.2 25.6 Cooling capacity kW 32.8 45.4 53.0 68.1 79.5
heating kW 4.2 7 8.5 12.6 17.3 21.5 25.9 Nominal input kW 12.7 17.0 21.2 25.5 31.8
Dimensions HxWxD mm 1,444x645x700 1,220x1,290x700 1,444x1,290x700 1,535x1,930x700 1,535x2,575x700 1,535x3,220x700 1,535x3,865x700 Dimensions HxWxD mm 1,535x1,930x700 1,535x2,575x700 1,535x2,575x700 1,535x3,865x700 1,535x3,865x700
Weight kg 140 208 240 390 530 675 800 Weight kg 375 510 510 780 780
Sound power/pressure level dB(A) 69/- 78/- 78/- 78/- 81/- 81/- 83/- Sound power/pressure level dB(A) 78/62 81/64 81/64 83/67 83/67
62 63
EPC99.09E•General 11/10/00 16:23 Page 66
low noise
option
CHILLERS
EUWA* EUWA*-KX CHILLERS
air cooled air cooled
• low operating sound level • optimised for use with R-134a
• single screw compressor • special Daikin single screw compressor
• high energy efficiency ratio • high EER
• operating range from • low noise option available
-15°C to 43°C • BMS connection possible
• available in 6 models with • evaporators located in the middle
nominal cooling capacities of the unit
EUWA* 40 - 60 KAX
from 101 to 300 kW • 2 switchboxes (high and low voltage)
• units with special pressure vessel • new compressor housing
approval are available on request • victaulic joints for plate heat exchangers
• pre mounted 5 inch piping for easier
field piping operations (from 160hp on)
EUWA* 40 - 60 KA
Refrigerant : R-134a • Power supply: Y1 = 3~, 50Hz, 400V; T1 = 3~, 50Hz, 230V (only EUWA*40-120K(A)X)
Refrigerant : R-22 • Power supply: Y1: 3~, 50 Hz, 400V / T1: 3~, 50Hz, 230V Refrigerant : R-134a • Power supply: Y1 = 3~, 50Hz, 400V; T1 = 3~, 50Hz, 230V (only EUWA*40-120K(A)X)
COOLING ONLY EUWA*40KA EUWA*50KA EUWA*60KA EUWA*80KA EUWA*100KA EUWA*120KA COOLING ONLY EUWA*120KAX EUWA*160KX EUWA*180KX EUWA*200KX
Cooling capacity kW 101 129 161 202 258 300 Cooling capacity kW 316 400 438 475
Nominal input kW 38.5 52.7 59.0 78.5 106 115 Nominal input kW 130 164 178 191
Dimensions HxWxD mm 2,135x3,980x1,110 2,156x3,980x2,210 Dimensions HxWxD mm 2,156x3,980x2,210 2,156x5,906x2,265
Weight kg 1,205 1,345 1,530 2,500 2,750 2,950 Weight kg 3,260 5,400 5,450 5,500
Sound power/pressure level dB(A) 88/- 92/- 94/- 97/- 96/- 95/- Sound power/pressure level dB(A) 98/- 99/- 100/- 100/-
* =T(Germany - TüV), K(Finland - TTK), M(France - SdM), B(Italy - ISPESL), Q(Poland-UDT), D(The Netherlands - RLK law), S(Sweden - AB-Staten) according * =T(Germany - TüV), K(Finland - TTK), M(France - SdM), B(Italy - ISPESL), Q(Poland-UDT), D(The Netherlands - RLK law), S(Sweden - AB-Staten) according
64 65
to corresponding pressure vessel approval. to corresponding pressure vessel approval.
EPC99.09E•General 11/10/00 16:24 Page 68
CHILLERS
EUWA*-LZ EUWAC CHILLERS
air cooled air cooled
• Daikin single screw compressor
• all components optimised for use with R-407C refrigerant
• electronic DDC control
• modular format
• standard operating range down to -15°C ambient
• high quality, standard anti-corrosion treated components
• moisture indicator as standard
• victaulic joints as standard
EUWA*40 - 60LZ
• chilled water temperatures down to 4°C
(down to -10°C with ZL option and glycol)
• optional BMS and DICN
connection available
• double refrigeration circuits
(from 160hp on)
• pre-mounted, 5 inch piping
for easier field connection • centrifugal fan
• cooling only application
• nom. cooling capacities ranging
from 11.5 to 23.0 kW
EUWA*80 - 120LZ • available in 3 standard sizes
Refrigerant : R-407C • Power supply: Y1 = 3~, 50Hz, 400V
• specially designed for inside
installation
COOLING ONLY EUWA*40LZ (1) EUWA*50LZ (1) EUWA*60LZ EUWA*80LZ (1) EUWA*100LZ (1)
Cooling capacity kW 99 131 155 205 269
Nominal input kW 43 55 66 87 112
Dimensions HxWxD mm 2,160x2,340x2,238 2,165x4,280x2,238
Weight kg 1,346 1,610 1,637 2,833 3,152
Sound power/pressure level dB(A) 88/- 92/- 96/- 95/- 96/-
Refrigerant : R-22 • Power supply: W1 = 3N~, 50Hz, 380/415V; T1 = 3~, 50Hz, 220V.
Refrigerant : R-407C • Power supply: Y1 = 3~, 50Hz, 400V
COOLING ONLY EUWAC5FA EUWAC8FA EUWAC10FA
COOLING ONLY EUWA*120LZ (1) EUWA*160LZ EUWA*180LZ EUWA*200LZ Cooling capacity kW 11.5 18.8 23.0
Cooling capacity kW 310 419 479 539 Nominal input kW 5.2 9.0 11.1
Nominal input kW 135 171 202 232 Maximum external static pressure mmH2O 10 15 15
Dimensions HxWxD mm 2,165x4,280x2,238 2,165x5,906x2,238 Dimensions HxWxD mm 1,345x795x605 1,290x1,125x605 1,395x1,175x605
Weight kg 3,404 5,002 5,044 5,086 Weight kg 175 230 270
Sound power/pressure level dB(A) 97/- 100/- 101/- 102/- Sound power/pressure level dB(A) -/53 -/59 -/60
66
* =T (Germany - TüV), K(Finland - TTK), M(France - SdM), B(Italy - ISPESL), Q(Poland - UDT), D(The Netherlands - RLK law), S(Sweden - AB-Staten) 67
according to corresponding pressure vessel approval. / (1) Preliminary info
EPC99.09E•General 11/10/00 16:25 Page 70
EUWL*40-100KX
CHILLERS
CHILLERS
EUW(H) EUW(L)*-KX water cooled /
water cooled • the most compact unit in the market
remote condenser
• optimised design for use with R-134a
• special Daikin screw compressor
• high EER
• electronic controller
• control on cold and hot side
• voltage free contacts (for alarms etc)
• LWE control
• lead lag switch
• victaulic joints as standard
• totally independent twin circuits
(from 120hp on) EUW*120-200KX
• condenserless units available throughout
the range
Refrigerant : R-134a • Power supply: T1 = 3~, 50Hz, 230V/ Y1 = 3~, 50Hz, 4000V
Refrigerant : R-134a • Power supply: T1= 3~,50Hz, 230V / Y1 = 3~, 50Hz, 400V
* =T(Germany - TüV), K(Finland - TTK), M(France - SdM), B(Italy - ISPESL), Q(Poland-UDT), D(The Netherlands - RLK law), S(Sweden - AB-Staten)
68 69
according to corresponding pressure vessel approval.
EPC99.09E•General 11/10/00 16:25 Page 72
DAIKIN INTEGRATED
CHILLER NETWORK
D.I.C.N EHMC HYDRAULIC MODULE
• 3 models available
• 100 l tank for all sizes (even for 35 H.P. chiller)
models R-22 models R-407C models R-134a
• freeze up protection
EUWAT(B,M,D)40,50,60KAY1/T1 EUWAT(B,D,K,Q,M,S)40,50,60,80,100,120,160,180,200LZY1 EUWAT(B,D,K,Q,M,S)40,50,60,80,100,120KAXY1/T1 • low and high static pump (option)
EUWAT(B,M,D)80,100,120KAY1/T1 EUWAT(B,D,K,Q,M,S)160,180,200KXY1 • specially designed for Daikin EUWA5-30HD,
EUWT(B,D,K,Q,M,S)40,60,80,100,120KXY1/T1
EUWT(B,D,K,Q,M,S)160,180,200KXY1/T1
EUWA5-35HDZ and EUWY5-30HD water chillers
• standard drain kit (for indoor use)
• standard dual pressure ports
(before & behind the pump)
Daikin chillers with DDC control can be equipped with DICN which allows the simultaneous
operation of up to 4 chillers as if they were a single unit, in order to deliver the required
EHMC10-15-30 AV1010
cooling capacity. This results in precise and efficient capacity control and is also useful for
back up purposes, ensuring that the necessary amount of cooling is available and
guaranteeing reliable operation of the chiller plant.
This function enables a Daikin 2MW chiller plant to be operated via a single controller.
(1) for high static option Power supply: V1 = 1~, 50Hz, 230V.
70 71
EPC99.09E•General 11/10/00 16:25 Page 74
FWV-BA6V1 / FWV-BAF6V1 1 2 3 4 6 8 10
Cooling capacity (2-/4-pipe) kW 1.31 / 1.29 1.98 / 1.95 2.90 / 2.86 3.89 / 3.83 4.60 / 4.54 6.29 / 6.20 7.84 / 7.73
Heating capacity (2-/4-pipe) kW 1.77 / 1.90 2.55 / 2.49 3.64 / 3.68 4.88 / 4.74 6.35 / 6.05 8.03 / 8.07 10.1 / 10.2
Nominal input H/L W 38/20 66/27 60/29 84/36 111/54 180/87 242/111
Dimensions HxWxD mm 560x775x228 560x985x228 560x1195x228 560x1405x253
Weight (2-/4-pipe) kg 20.1 / 21.2 20.6 / 21.7 26.1 / 27.4 31.8 / 33.5 31.8 / 33.5 40.8 / 43.1 40.8 / 43.1
Air flow rate (2-/4-pipe) M l/s 52.9 / 51.9 68.7 / 67.4 95.9 / 93.9 133.1 / 130.4 171.7 / 168.3 224.6 / 220.1 278.9 / 273.4
FA N C O I L U N I T S
FWV(M)/FWH(M)/FWHC Sound pressure level
Sound power level
H/L
H/L
dB(A)
dB(A)
33/20
47/34
40/23
54/37
34/19
48/33
38/23
52/37
46/32
60/46
48/35
62/49
53/40
67/54
FWH-BA6V1 / FWH-BAF6V1 1 2 3 4 6 8 10
Cooling capacity (2-/4-pipe) kW 1.31 / 1.29 1.98 / 1.95 2.90 / 2.86 3.89 / 3.83 4.60 / 4.54 6.29 / 6.20 7.84 / 7.73
Heating capacity (2-/4-pipe) kW 1.77 / 1.90 2.55 / 2.49 3.64 / 3.68 4.88 / 4.74 6.35 / 6.05 8.03 / 8.07 10.1 / 10.2
Nominal input H/L W 38/20 66/27 60/29 84/36 111/54 180/87 242/111
Dimensions HxWxD mm 228x775x560 228x985x560 228x1,195x560 253x1,405x560
Weight (2-/4-pipe) kg 20.9 / 22 22.1 / 23.2 27.7 / 29 33.3 / 35 33.3 / 35 42.3 / 44.6 43.1 / 45.4
Air flow rate (2-/4-pipe) M l/s 52.9 / 51.9 68.7 / 67.4 95.9 / 93.9 133.1 / 130.4 171.7 / 168.3 224.6 / 220.1 278.9 / 273.4
Sound pressure level H/L dB(A) 33/20 40/23 34/19 38/23 46/32 48/35 53/40
Sound power level H/L dB(A) 47/34 54/37 48/33 52/37 60/46 62/49 67/54
FWHM-BA6V1 / FWHM-BAF6V1 1 2 3 4 6 8 10
Cooling capacity (2-/4-pipe) kW 1.31 / 1.29 1.98 / 1.95 2.90 / 2.86 3.89 / 3.83 4.60 / 4.54 6.29 / 6.20 7.84 / 7.73
Heating capacity (2-/4-pipe) kW 1.77 / 1.90 2.55 / 2.49 3.64 / 3.68 4.88 / 4.74 6.35 / 6.05 8.03 / 8.07 10.1 / 10.2
Nominal input H/L W 38/20 66/27 60/29 84/36 111/54 180/87 242/111
Dimensions HxWxD mm 223x706x535 223x916x535 223x1,126x535 248x1,336x535
Weight (2-/4-pipe) kg 15.3 / 16.4 16.1 / 17.2 20.4 / 21.7 24.8 / 26.5 25.1 / 26.7 33.3 / 35.6 33.3 / 35.6
Air flow rate (2-/4-pipe) M l/s 52.9 / 51.9 68.7 / 67.4 95.9 / 93.9 133.1 / 130.4 171.7 / 168.3 224.6 / 220.1 278.9 / 273.4
Sound pressure level H/L dB(A) 33/20 40/23 34/19 38/23 46/32 48/35 53/40
Sound power level H/L dB(A) 47/34 54/37 48/33 52/37 60/46 62/49 67/54
72 73
EPC99.09E•General 11/10/00 16:25 Page 76
Daikin Chiller S E L E C T I O N S O F T WA R E
Purpose designed, user friendly and powerful, this facility simplifies and speeds up
the selection of Daikin chillers. The built-in programme enables the most suitable selection
to be made according to cooling/heating capacity and specified design conditions.
Extensive print outs are available.
The Daikin chiller selection programme runs under Windows95®, Windows98® and
WindowsNT®, without specific computer requirements.
Daikin chillers are equipped with a user friendly electronic controller, complete with
electronic sensors to monitor and provide information on water inlet and outlet temperatures
and air/coil temperatures. The controller also incorporates a number of safety devices, timer
functions, an adjustable thermostat function etc.
The selection software covers a complete database of all chiller units, which includes
specifications, wiring diagrams, piping diagrams, technical data, options and
installation space.
74 75
EPC99.09D•Eng•OK 31/03/00 12:21 Page 78
ER
5
CONDENSING UNIT
CONDENSING UNITS
Refrigerant : R-22 • Power supply: T1 = 3~, 50Hz, 230V
77