pRRU5921 Description-Renew
pRRU5921 Description-Renew
V100R015C10
Description
Issue 03
Date 2019-06-06
and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective
holders.
Notice
The purchased products, services and features are stipulated by the contract made between Huawei and
the customer. All or part of the products, services and features described in this document may not be
within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements,
information, and recommendations in this document are provided "AS IS" without warranties, guarantees or
representations of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.
Website: http://www.huawei.com
Email: support@huawei.com
Contents
1 Introduction .............................................................................................................................. 1
1.1 Appearance............................................................................................................................................................ 1
1.2 Physical Ports ........................................................................................................................................................ 2
1 Introduction
1.1 Appearance
Figure 1-1 shows the appearance of a pRRU5921.
(1) Anti-theft lock (2) ETH CPRI_E1 (3) CPRI RX/TX (4) PoE/DC CPRI_E0
Silkscreen Description
PoE/DC CPRI_E0 Used for connecting to an electrical RHUB or an optical
NOTE
RHUB.
The PoE/DC silkscreen indicates When connected to an electrical RHUB, this port is
that the CPRI_E0 port supports used for CPRI data transmission and PoE power
PoE and DC power supply. supply.
When connected to an optical RHUB, this port is used
only for DC power supply and does not support data
transmission.
ETH CPRI_E1 In DC power supply mode, if the pRRU is connected to an
NOTE
optical RHUB, this port can be used for cascading with a
The PoE silkscreen indicates that
pRRU. In this case, the two cascaded pRRUs are 20 m
the CPRI_E1 port supports PoE apart from each other at most, and must have total power
power supply. consumption of no more than 130 W and run different
network standards.
CPRI RX/TX Used for connecting to an optical RHUB to transmit CPRI
data
Silkscreen Description
Used for anti-theft of the pRRU5921. Anti-theft locks are
not delivered and must be prepared by customers if
required.
Used for preventing device disassembly
In PoE power supply mode, the pRRU5921 can only be connected to an electrical RHUB, and
the CPRI RX/TX port cannot be connected to an optical module. In DC power supply mode,
the pRRU5921 can only be connected to an optical RHUB, and the ETH CPRI_E1 and DC
CPRI_E0 ports cannot be connected to an electrical RHUB.
2 Technical Specifications
2.2 Capacity
Table 2-2 Capacity
Mode Capacity
GSM 2 subbands (4 carriers on each subband)
UMTS 4 carriers
LTE FDD 3 carriers
LTE TDD 3 carriers
GSM+UMTS 2 GSM subbands + 4 UMTS carriers
GSM+LTE FDD+LTE TDD 2 GSM subbands + 3 LTE FDD carriers + 3 LTE
TDD carriers
UMTS+LTE FDD+LTE TDD 4 UMTS carriers + 3 LTE FDD carriers + 3 LTE
TDD carriers
GSM+UMTS+LTE FDD+LTE TDD 2 GSM subbands + 4 UMTS carriers + 3 LTE
FDD carriers + 3 LTE TDD carriers
NR 1 carriers (100MHz)
In BBU access scenarios, pRRU capacity specifications are calculated based on carriers. In RF input
scenarios, pRRU capacity specifications are calculated based on subbands.
ATBR in the TX/RX Channel column indicates that the RF module has A TX channels and B RX
channels.
CxD in the Maximum Output Power column indicates that the RF module has C TX channels,
each with a maximum output power of D mW.
Item Specifications
Operating temperature –5°C to +40°C
Storage temperature –40°C to +70°C
Relative humidity 5% RH to 95% RH
Absolute humidity 1 g/m3 to 30 g/m3
Atmospheric pressure 70 kPa to 106 kPa
IP rating IP20
Operating environment EUROPEAN ETSI EN 300 019-1-3 Class 3.1
"Temperature-controlled locations"
Item Specifications
environment transportation"
Anti-seismic ETSI 300 019-1-3 Class 3.2
performance IEC 60068-2-57 (1999-11) Environmental testing - Part
2-57: Tests - Test Ff: Vibration - Time-history method
YD5083-99: Interim Provisions for Test of Anti-seismic
Performance of Telecommunications Equipment (telecom
industry standard in the People's Republic of China)
GR63 5.4.1 Zone 4: NEBSTM Requirements: Physical
Protection
Protection from damp Class B
heat, salt mist, and mold
growth
Item Specifications
EMC The base station meets the EMC requirements and complies with the
following standards:
CISPR 22 Class B
VCCI Class B
GB 9254 Class B
IEC 61000-3-2
IEC 61000-3-3
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-6
IEC 61000-4-11
3GPP 3GPP TS 36.104
3GPP TS 25.104
3GPP TS 36.141
3GPP TS 25.141
3GPP TS 37.104
3GPP TS 37.141
Environment protection RoHS
standard
Item Specifications
Surge protection standard N/A
Protection standard YD 5098-2001
IEC 61000-4-5
ETSI EN 301 489
ITU-T K.20
Safety standard GB 4943
IEC/EN/UL 60950-1
IEC/EN 60215
Environment standard ETSI EN 300 019-2-1
ETSI EN 300 019-2-2
ETSI EN 300 019-2-3
IEC 60068-2
ETL N/A