2D Barcode Scanner
User Guide
Troubleshooting
Problem Possible Cause Possible Solution
Scanner does not Power off Insert the adapter.
turn on Interface fails Check the cable. Version:1.0
Did not enable the
Please enable it.
Scanner power on, barcode
but it cannot read Scanner cannot read Please contact the
the barcode. the barcode type. dealer or us
Wrong distance. Move the scanner.
Scanner does not send Scanner is not Check all cable to
data to host computer connected to the host. host computer.
Check scanner an PC
Scanner and the host
Receive garbled with communication port
baud rate settings are
Rs232 baud rate settings are
inconsistent
the same.
NOTE: Profile
For stability enhancement of scanner or other Input voltage DC 5V± 0.25V
properties,Manufacturer may modify the software (including
Power 1.40W(working) ; 0.40W(standby)
firmware).
Current 400mA(Max); 300mA(working); 70mA(standby)
A standard packing includes a user guide,a cable and a Scanner
Image Sensor 752 × 480 cmos sensor
.
Rotational Sensitivity ±360°
Viewing Angle ±40°
PDF417,QR Code,Data Matrix,HanXin code,Aztec,etc
Profile Symbologies Code 39, Code 128, Codebar,UPC, EAN,Interleaved 2
of 5,etc
Prompt beeper,LED
It is developed to meet the increasing needs of 2D barcode
identification. It does not only accurately and quickly read both Interface USB VCP/USB HID
1D and 2D barcodes, but also seamlessly captures barcodes on Trig mode Hand-held/hand-free
electronic screens (such as mobile phone) and provides an dimension L×W×H:190mm× 65mm× 85mm
effective data acquisition tool for e-coupons and e-tickets. It’s
Weight 156g(without cable)
suitable for a wide variety of applications. Compared to the
Cable 2m
expensive imported scanners, It is definitely a cost effective and
high performance product for you! Connector RJ-45
Material PC
Temperature -5°C~ 45°C(working) ;- 40°C~60°C(Storage)
Humidity 5%~95%(non-condensing)
Parts of the Scanner Set mode online/scanning
firmware update online
Accuracy ≥ 5mil
depth of focus 40mm~300mm
EMC:EN 55022,EN55024
security classification Electrical safety:EN 60950-1
Waterproof and dustproof:IP52
1 2
Installing the Cable Removing the Cable
USB Cable
1.Refer to the picture, connect the host with the scanner;
2.Switch on the host. If the installation is successful, the beeper
and LED will work.
3.Scanner can work without External power supply.
4.Host will automatically detect the scanner.
1. Find the release-hole.
2. Insert a thin wire into the hole and pull out the cable gently.
Parameter settings
Set from BarcodeSetTool
Rs232 cable If the scanner is connected correctly, you can use the software
of configuration management for the corresponding parameter
settings
1. Make sure the power off.
2. Insert the RJ45 into the scanner.
3. Connect the RS232 to the host.
4. Plug the power adapter.
5. Power on the host. If connect right, it will prompt from beeper
and LED.
Please contact the local agency for the software.
3 4
Scan the barcode 3 protocols
Protocols command
1.Single Setting Type PID FID Parameter
1Byte 1Byte 1Byte ––
Scanning the corresponding 'set barcode'.
Example: Scan the right barcode, set
Instruction
’sensing mode’.
Type Length Describe
2.Multiple Setting
TYPE 1Byte Command type
Reading ‘Multiple setting code’, You can perform a variety of PID 1Byte Property ID
functions set.. Function ID, FID as a parameter
Example: Scan the right barcode, bytes instructions:
Set ‘Sensing mode’ 7bit 6bit parameter length
FID 1Byte
0 0 No
‘Flash always on’ ’aimer flash
0 1 1byte
blinking’
1 0 2byte
More ‘ Multiple setting code’, 1 1 >2byte
Please Contact local agents .
Parameter length according to FID.
If the length is longer than two
PARAM –– bytes, The first two bytes of
Set up from the host parameters indicate the length
of parameters.
Note : Please contact the local agency for more information .
1 This section is suitable for the scanner with the RS232 cable
or USB cable.
2 The scanner must be setup VCP mode for the USB type.
UART Parameters
(1) Baud rate:115200 bps;
(2) Data bits transmitted:8 data bits;
(3) stop bits:1 bit;
(4) parity check: NO;
5 6
Scan Beeper
Hand-held Mode Scanner through different buzzer to indicate status. It
defines the different status in the following table.
1. Ensure Scanner, Cables, and the Host are connected,
then turn the unit Power ON;
2. Press & hold Trigger. Illumination LED and Aiming LED cast Beeper Instructions
an Illumination Pattern(red light)and an Aiming Pattern(green
2 short Start
light).
1 short Success read
3. On a successful reading, there will be a beep sound,
illumination & aiming patterns die out. The scanner the transmits
barcode message to the Host.
LED
Scanner also through different LED to indicate working status. It
defines the different status in the following table.
LED Instructions
Hand-held Mode Hands-Free Mode
OFF Power off or standby.
Light for 1s Success read
Hands-Free Mode
1. Select reading mode ‘sensing mode’or ’continuous
mode’,when working in hands-free mode.
2. Adjust the stand height for the optimum reading stance.
7 8
Setting Barcode Chinese-sensible
code enable
Chinese-sensible
code disable
Instruction Settings
Restore factory settings
DataMatrix code enable DataMatrix code disable
Start decoding Stop decoding
Aztec code enable Aztec code disable
Disable all decoding Enable 1D decoding
Code11 Configure
Code11 code enable Code11 code disable
Enable 2D decoding Enable all decoding
Check digit verification disable Check digit verification one digit
Barcode Configure
Check digit verification two digits Check digit verification auto
2D barcode settings
QR code enable QR code disable
Code39 Configure
PDF417 code enable PDF417 code disable Code39 code enable Code39 code disable
9 10
Code39 verification disable Code32 verification EAN - 8 code enable EAN - 8 code disable
Code93 Configure Codebar Code Configure
Code93 code enable Code93 code disable Codebar code enable Codebar code disable
Codebar verification Enable Codebar verification Disable
Code128 Configure
Code128 code enable Code128 code disable
Standard 2 of 5 Code Configure
Standard 2 of 5 Code Enable Standard 2 of 5 Code Disable
UPC Configure
UPC-A code enable UPC-A code disable
Verification Disable Verification Enable
UPC - E code enable UPC - E code disable
Matrix 2 of 5 Code Configure
Matrix 2 of 5 Code Enable Matrix 2 of 5 Code Disable
EAN Code Configure
EAN - 13 code enable EAN - 13 code disable
11 12
Verification Enable Verification Disable Gs1 Databar Limited Enable GS1 Databar Limited Disable
Gs1 Databar Expanded Enable GS1 Databar Expanded Disable
Interleaved 2 of 5 Code Configure
Interleaved 2 of 5 Code Enable Interleaved 2 of 5 Code Disable
Plessey Code Configure
Verification Enable Verification Disable Plessey code enable Plessey code disable
MSI Code Configure China Post Code Configure
MSI Code Enable MSI Code Disable China Post code enable China Post code disable
Verification Disable Verification Enable
Interface Configure
Gs1 Databar Code Configure Uart USB HID
Gs1 Databar Omni- Gs1 Databar Omni-
Directional Enable Directional Disable
Uart baud rate 9600 Uart baud rate 19200
13 14
Uart baud rate 38400 Uart baud rate 57600 Symbology identifier enable Symbology identifier disable
Uart baud rate 115200 Uart baud rate 12800
Keyboard Layout
Uart baud rate 230400 Uart baud rate 25600
USA Spanish
Uart baud rate 460800
German French
Note: Baud rate settings is set only for RS232 scanner. In VCP
mode, baud rate is in Adaptive mode. You must set baud rate Italian Sweden
in 115200.
UK Brazil
Transmission Configure
Prefix settings insert ‘tab’ Prefix settings insert ‘\r\n’ Latin America India
Suffix settings insert ‘tab’ Suffix settings insert ‘\r\n’ Korea Russia
15 16
Running Configure Always on
Trigger mode
Trigger mode Continuous mode
Aimer flashing
Always off Blinking
Automatic mode Sensing mode
Always on
Pulse mode
Buzzer Settings
Auto sleep Settings Low Volume Medial Volume
Auto sleep enable Auto sleep disable
High Volume Buzz Num 0
Auto sleep Settings
Buzz Num 1 Buzz Num 2
Always off Blinking
17 18