Computer Controlled Steam Sterilizer,
with SCADA
Engineering and Technical
Teaching Equipment                                                                                                                        BIEV
                                                                                                                                                                               Teaching
                                                                                                                                                                              Technique
                                                                                                                                                                                 used
                                                                                                                                  EDIBON        SCADA System
                                                                                                                                                                                           Computer
                                                                                                                                                                                          (not included in
                                                                                                                              2                         3                4                  the supply)
                                                                                                                    Control Interface                Data        Software for:
                                                                                                                          Box                      Acquisition   - Computer Control
                                                                                                                                                     Board       - Data Acquisition
                                                                                                                                                                 - Data Management
                                                                                                                 5 Cables and Accessories
                                                                                                                 6 Manuals
                                                                                                         * Minimum supply always includes: 1 + 2 + 3 + 4 + 5 + 6
                                                                                                             (Computer not included in the supply)
            1 Unit: BIEV. Computer Controlled Steam Sterilizer
Key features:
   hh   Advanced Real-Time SCADA.
   hh   Open Control + Multicontrol + Real-Time Control.
   hh   Specialized EDIBON Control Software based on LabVIEW.
   hh   National Instruments Data Acquisition board (250 KS/s, kilo samples per second).
   hh   Calibration exercises, which are included, teach the user how to calibrate a
        sensor and the importance of checking the accuracy of the sensors before taking
        measurements.
   hh   Projector and/or electronic whiteboard compatibility allows the unit to be
        explained and demonstrated to an entire class at one time.
   hh   Capable of doing applied research, real industrial simulation, training courses,
        etc.
   hh   Remote operation and control by the user and remote control for EDIBON technical
        support, are always included.
   hh   Totally safe, utilizing 4 safety systems (Mechanical, Electrical, Electronic &
        Software).
   hh   Designed and manufactured under several quality standards.
   hh   Optional ICAI software to create, edit and carry out practical exercises, tests,
        exams, calculations, etc. Apart from monitoring user's knowledge and progress
        reached.
   hh   This unit has been designed for future expansion and integration. A common
        expansion is the EDIBON Scada-Net (ESN) System which enables multiple students
        to simultaneously operate many units in a network.
                                              http://www.edibon.com/products/catalogues/en/keyfeatures.pdf   http://www.youtube.com/embed/CEgMr00oBPw
For more information about Key Features, click here
    ISO 9001: Quality Management (for                          European Union Certificate                             Certificates ISO 14001 and ECO-                 “Worlddidac Quality Charter”
   Design, Manufacturing, Commercialization                           (total safety)                                  Management and Audit Scheme                       and Platinum Member of
            and After-sales service)                                                                                     (environmental management)                           Worlddidac
                                                                                                             1
                                COMPLETE TECHNICAL SPECIFICATIONS (for main items)
With this unit there are several options and possibilities:
  - Main items: 1, 2, 3, 4, 5 and 6.
  - Optional items: 7, 8 and 9.
Let us describe first the main items (1 to 6):
1 BIEV. Unit:
  The Computer Controlled Steam Sterilizer “BIEV”, consists mainly of:
     Industrial Microcomputer and touch screen.
     Double CPU (control and registration).
     Printer Data processing/ Ethernet connection.
     Vacuum ejector/ water economizer.
     Set Lower Guides.
     CE Marking.
     Continuous Bedroom.
     Steam generator 18 kW.
     Independent water circuits.
     Chamber and steam gauges on the front.
     Volume: 252 l.
  The complete unit includes as well:
     Advanced Real-Time SCADA.
     Open Control + Multicontrol + Real-Time Control.
     Specialized EDIBON Control Software based on LabVIEW.
     National Instruments Data Acquisition board (250 KS/s, kilo samples per
     second).
     Calibration exercises, which are included, teach the user how to calibrate a
     sensor and the importance of checking the accuracy of the sensors before
     taking measurements.                                                                                Unit: BIEV
     Projector and/or electronic whiteboard compatibility allows the unit to be explained and
     demonstrated to an entire class at one time.
     Capable of doing applied research, real industrial simulation, training courses, etc.
     Remote operation and control by the user and remote control for EDIBON technical support,
     are always included.
     Totally safe, utilizing 4 safety systems (Mechanical, Electrical, Electronic & Software).
     Designed and manufactured under several quality standards.
     Optional ICAI software to create, edit and carry out practical exercises, tests, exams,
     calculations, etc. Apart from monitoring user's knowledge and progress reached.
     This unit has been designed for future expansion and integration. A common expansion is
     the EDIBON Scada-Net (ESN) System which enables multiple students to simultaneously
     operate many units in a network.
 BIEV/CIB. Control Interface Box:
 The Control Interface Box is part of the SCADA system.
 Control interface box with process diagram in the front panel and with the same distribution that
 the different elements located in the unit, for an easy understanding by the student.
 All sensors, with their respective signals, are properly manipulated from -10V. to +10V. computer
 output.
 Sensors connectors in the interface have different pines numbers (from 2 to 16), to avoid
 connection errors.
 Single cable between the control interface box and computer.
 The unit control elements are permanently computer controlled, without necessity of
 changes or connections during the whole process test procedure.
 Simultaneous visualization in the computer of all parameters involved in the process.
 Calibration of all sensors involved in the process.
 Real time curves representation about system responses.
 Storage of all the process data and results in a file.
 Graphic representation, in real time, of all the process/system responses.
 All the actuators’ values can be changed at any time from the keyboard allowing the
 analysis about curves and responses of the whole process.
 All the actuators and sensors values and their responses are displayed on only one screen in the
 computer.                                                                                            BIEV/CIB
 Shield and filtered signals to avoid external interferences.
 Real time computer control with flexibility of modifications from the computer keyboard of the
 parameters, at any moment during the process.
 Real time computer control for pumps, compressors, heating elements, control valves, etc.
 Real time computer control for parameters involved in the process simultaneously.
 Open control allowing modifications, at any moment and in real time, of parameters involved in the
 process simultaneously.
 Three safety levels, one mechanical in the unit, another electronic in the control interface and
 the third one in the control software.
                                                                 2                                                www.edibon.com
                                               Complete Technical Specifications (for main items)
 3   DAB. Data Acquisition Board:
     The Data Acquisition board is part of the SCADA system.
     PCI Express Data acquisition board (National Instruments) to be placed in a computer slot. Bus
     PCI Express.
     Analog input:
        Number of channels= 16 single-ended or 8 differential. Resolution=16 bits, 1 in 65536.
        Sampling rate up to: 250 KS/s (kilo samples per second).
        Input range (V)=±10 V. Data transfers=DMA, interrupts, programmed I/0. DMA channels=6.
     Analog output:
        Number of channels=2. Resolution=16 bits, 1 in 65536.
        Maximum output rate up to: 900 KS/s.
        Output range (V)=±10 V. Data transfers=DMA, interrupts, programmed I/0.                                   DAB
     Digital Input/Output:
        Number of channels=24 inputs/outputs. D0 or DI Sample Clock frequency: 0 to 100 MHz.
     Timing: Number of Counter/timers=4. Resolution: Counter/timers: 32 bits.
     The Data Acquisition board model may change at any moment, providing the same or better
     features than those required for the unit.
 4   BIEV/CCSOF. Computer Control + Data Acquisition + Data Management Software:
     The three softwares are part of the SCADA system.
     Compatible with actual Windows operating systems. Graphic and intuitive simulation of the process in
     screen. Compatible with the industry standards.
     Registration and visualization of all process variables in an automatic and simultaneous way.
     Flexible, open and multicontrol software, developed with actual windows graphic systems, acting
     simultaneously on all process parameters.
     Management, processing, comparison and storage of data.
     Sampling velocity up to 250 KS/s (kilo samples per second).
     Calibration system for the sensors involved in the process.                                               BIEV/CCSOF
     It allows the registration of the alarms state and the graphic representation in real time.
     Comparative analysis of the obtained data, after the process and modification of the conditions during
     the process.
     Open software, allowing the teacher to modify texts, instructions. Teacher’s and student’s
     passwords to facilitate the teacher’s control on the student, and allowing the access to different work
     levels.
     This unit allows the 30 students of the classroom to visualize simultaneously all the results
     and the manipulation of the unit, during the process, by using a projector or an electronic
     whiteboard.
5    Cables and Accessories, for normal operation.
6    Manuals:
     This unit is supplied with 8 manuals: Required Services, Assembly and Installation, Interface and
     Control Software, Starting-up, Safety, Maintenance, Calibration & Practices Manuals.
*References 1 to 6 are the main items: BIEV + BIEV/CIB + DAB + BIEV/CCSOF + Cables and Accessories + Manuals are included in
 the minimum supply for enabling normal and full operation.
                                                                        3                                                   www.edibon.com
                 REQUIRED SERVICES                                               DIMENSIONS AND WEIGHTS
- Power supply: three-phase, 380V/50Hz or 208V/60Hz, 20 kW.       BIEV:
- Computer.                                                          Unit:
                                                                        - Dimensions: 900 x 1824 x 1342 mm approx.
                                                                                        (35.43 x 71.81 x 52.83 inches approx.)
                                                                        - Gross weight: 963 Kg approx.
                                                                                        (2123 pounds approx.).
                                                                        - Net weight: 711 Kg approx.
                                                                                        (1567 pounds approx.).
                                                                   Camera:
                                                                        - Dimensions: 500 x 500 x 1200 mm approx.
                                                                                        (19.68 x 19.68 x 47.24 inches approx.)
                                                                   Control Interface Box:
                                                                        - Dimensions: 490 x 330 x 310 mm approx.
                                                                                        (19.29 x 12.99 x 12.20 inches approx.)
                                                                        - Weight:       10 Kg approx.
                                                                                        (22 pounds approx.).
                                                              4                                                           www.edibon.com
                                     COMPLETE TECHNICAL SPECIFICATIONS (for optional items)
Additionally to the main items (1 to 6) described, we can offer, as optional, other items from 7 to 9.
All these items try to give more possibilities for:
   a) Technical and Vocational Education configuration. (ICAI)
   b) Multipost Expansions options. (MINI ESN and ESN)
                                                a) Technical and Vocational Education configuration
7 BIEV/ICAI. Interactive Computer Aided Instruction Software.
  This complete software package consists of an Instructor Software (EDIBON Classroom Manager - ECM-SOF) totally integrated with the
  Student Software (EDIBON Student Labsoft - ESL-SOF). Both are interconnected so that the teacher knows at any moment what is the theoretical and
  practical knowledge of the students.
  This software is optional and can be used additionally to items (1 to 6).
                                                                                                                   Instructor Software
  - ECM-SOF. EDIBON Classroom Manager (Instructor Software).
  ECM-SOF is the application that allows the Instructor to register students,
  manage and assign tasks for workgroups, create own content to carry out
  Practical Exercises, choose one of the evaluation methods to check the
  Student knowledge and monitor the progression related to the planned
  tasks for individual students, workgroups, units, etc... so the teacher
  can know in real time the level of understanding of any student in the
  classroom.
                                                                                    ECM-SOF. EDIBON Classroom
  Innovative features:                                                               Manager (Instructor Software)
                                                                                      Application Main Screen          ECAL. EDIBON Calculations Program Package -
  • User Data Base Management.                                                                                                    Formula Editor Screen
  • Administration and assignment of Workgroup, Task and Training
    sessions.
  • Creation and Integration of Practical Exercises and Multimedia
    Resources.
  • Custom Design of Evaluation Methods.
  • Creation and assignment of Formulas & Equations.
  • Equation System Solver Engine.
  • Updatable Contents.
  • Report generation, User Progression Monitoring and Statistics.
                                                                                    ERS. EDIBON Results & Statistics
                                                                                      Program Package - Student
                                                                                           Scores Histogram             ETTE. EDIBON Training Test & Exam Program
                                                                                                                         Package - Main Screen with Numeric Result
                                                                                                                                         Question
  - ESL-SOF. EDIBON Student Labsoft (Student Software).
  ESL-SOF is the application addressed to the Students that helps them                                             Student Software
  to understand theoretical concepts by means of practical exercises
  and to prove their knowledge and progression by performing tests and
  calculations in addition to Multimedia Resources. Default planned tasks
  and an Open workgroup are provided by EDIBON to allow the students
  start working from the first session. Reports and statistics are available
  to know their progression at any time, as well as explanations for every
  exercise to reinforce the theoretically acquired technical knowledge.
  Innovative features:
  • Student Log-In & Self-Registration.
  • Existing Tasks checking & Monitoring.                                             ESL-SOF. EDIBON Student
                                                                                      LabSoft (Student Software)
  • Default contents & scheduled tasks available to be used from the                   Application Main Screen
    first session.                                                                                                     EPE. EDIBON Practical Exercise Program Package
                                                                                                                                       Main Screen
  •	Practical Exercises accomplishment by following the Manual
    provided by EDIBON.
  • Evaluation Methods to prove your knowledge and progression.
  • Test self-correction.
  • Calculations computing and plotting.
  • Equation System Solver Engine.
  • User Monitoring Learning & Printable Reports.
  • Multimedia-Supported auxiliary resources.
                                                                                    ERS. EDIBON Results & Statistics
  For more information see ICAI catalogue. Click on the following link:              Program Package - Question
                                                                                             Explanation
  www.edibon.com/en/files/expansion/ICAI/catalog                                                                        ECAL. EDIBON Calculations Program Package
                                                                                                                                      Main Screen
                                                                                5                                                                     www.edibon.com
                                               Complete Technical Specifications (for optional items)
                                                            b) Multipost Expansions options
8 MINI ESN. EDIBON Mini Scada-Net System for being used with
 EDIBON Teaching Units.
                                                                                                        MINI ESN.
 MINI ESN. EDIBON Mini Scada-Net System allows up to 30 students to work                        EDIBON Mini Scada-Net System
 with a Teaching Unit in any laboratory, simultaneously. It is useful for both,
 Higher Education and/or Technical and Vocational Education.
 The MINI ESN system consists of the adaptation of any EDIBON Computer
 Controlled Unit with SCADA integrated in a local network.                                                                       1 UNIT= up to 30
 This system allows to view/control the unit remotely, from any computer                                                        STUDENTS can work
                                                                                                                                  simultaneously
 integrated in the local net (in the classroom), through the main computer
 connected to the unit. Then, the number of possible users who can work with
 the same unit is higher than in an usual way of working (usually only one).
 Main characteristics:
 - It allows up to 30 students to work simultaneously with the EDIBON
                                                                                  Computer Controlled Steam Sterilizer (BIEV)
   Computer Controlled Unit with SCADA, connected in a local net.
 - Open Control + Multicontrol + Real Time Control + Multi Student
   Post.                                                                                                                           Software for:
                                                                                         Control                                   - Computer Control
 - Instructor controls and explains to all students at the same time.                 Interface Box                                - Data Acquisition
                                                                                                                                   - Data Management
 - Any user/student can work doing "real time" control/multicontrol
   and visualisation.
                                                                                                             Instructors'
 - Instructor can see in the computer what any user/student is doing                                           Central                 Mini Scada-Net
   in the unit.                                                                                               Computer                    Software
 -	Continuous communication between the instructor and all the
   users/students connected.
                                                                                                   LOCAL NET FOR 30 STUDENTS
 Main advantages:
 - It allows an easier and quicker understanding.
                                                                                                                            Note: The MINI ESN
 - This system allows you can save time and cost.                                                                           system can be used with
 - Future expansions with more EDIBON Units.                                                                                any EDIBON computer
                                                                                                                            controlled unit
 For more information see MINI ESN catalogue. Click on the following link:
 www.edibon.com/en/files/expansion/MINI-ESN/catalog
9 ESN. EDIBON Scada-Net Systems.
 This unit can be integrated, in the future, into a Complete Laboratory with many Units and many Students.
 For more information see ESN catalogue. Click on the following link:
 www.edibon.com/en/files/expansion/ESN/catalog
                                                                              6                                                                www.edibon.com
                                                    ORDER INFORMATION
           Main items (always included in the supply)                         Optional items (supplied under specific order)
Minimum supply always includes:                                             a) Technical and Vocational Education configuration
1   Unit: BIEV. Computer Controlled Steam Sterilizer.              7   BIEV/ICAI. Interactive Computer Aided Instruction Software.
2   BIEV/CIB. Control Interface Box.
3   DAB. Data Acquisition Board.                                                       b) Multipost Expansions options
4   BIEV/CCSOF. Computer Control + Data Acquisition +              8   MINI ESN. EDIBON Mini Scada-Net System for being used with
    Data Management Software.                                          EDIBON Teaching Units.
5   Cables and Accessories, for normal operation.                  9   ESN. EDIBON Scada-Net Systems.
6   Manuals.
*IMPORTANT: Under BIEV we always supply all the elements for
immediate running as 1, 2, 3, 4, 5 and 6.
                                                               7                                                           www.edibon.com
                                                 TENDER SPECIFICATIONS (for main items)
1 BIEV. Unit:
 The Computer Controlled Steam Sterilizer “BIEV”, consists mainly of:
   Industrial Microcomputer and touch screen.
   Double CPU (control and registration).
   Printer Data processing/ Ethernet connection.
   Vacuum ejector/ water economizer.
   Set Lower Guides.
   CE Marking.
   Continuous Bedroom.
   Steam generator 18 Kw.
   Independent water circuits.
   Chamber and steam gauges on the front.
   Volume: 252 l.
 The complete unit includes as well:
   Advanced Real-Time SCADA.
   Open Control + Multicontrol + Real-Time Control.
   Specialized EDIBON Control Software based on LabVIEW.
   National Instruments Data Acquisition board (250 KS/s, kilo samples per second).
   Calibration exercises, which are included, teach the user how to calibrate a sensor and the importance of checking the accuracy of the sensors before
   taking measurements.
   Projector and/or electronic whiteboard compatibility allows the unit to be explained and demonstrated to an entire class at one time.
   Capable of doing applied research, real industrial simulation, training courses, etc.
   Remote operation and control by the user and remote control for EDIBON technical support, are always included.
   Totally safe, utilizing 4 safety systems (Mechanical, Electrical, Electronic & Software).
   Designed and manufactured under several quality standards.
   Optional ICAI software to create, edit and carry out practical exercises, tests, exams, calculations, etc. Apart from monitoring user's knowledge and
   progress reached.
   This unit has been designed for future expansion and integration. A common expansion is the EDIBON Scada-Net (ESN) System which enables multiple
   students to simultaneously operate many units in a network.
2 BIEV/CIB. Control Interface Box:
 The Control Interface Box is part of the SCADA system.
 Control interface box with process diagram in the front panel.
 The unit control elements are permanently computer controlled.
 Simultaneous visualization in the computer of all parameters involved in the process.
 Calibration of all sensors involved in the process.
 Real time curves representation about system responses.
 All the actuators’ values can be changed at any time from the keyboard allowing the analysis about curves and responses of the whole process.
 Shield and filtered signals to avoid external interferences.
 Real time computer control with flexibility of modifications from the computer keyboard of the parameters, at any moment during the process.
 Real time computer control for parameters involved in the process simultaneously.
 Open control allowing modifications, at any moment and in real time, of parameters involved in the process simultaneously.
 Three safety levels, one mechanical in the unit, another electronic in the control interface and the third one in the control software.
3 DAB. Data Acquisition Board:
 The Data Acquisition board is part of the SCADA system.
 PCI Express Data acquisition board (National Instruments) to be placed in a computer slot.
 Analog input: Channels= 16 single-ended or 8 differential. Resolution=16 bits, 1 in 65536. Sampling rate up to: 250 KS/s (kilo samples per second).
 Analog output: Channels=2. Resolution=16 bits, 1 in 65536.
 Digital Input/Output: Channels=24 inputs/outputs.
 The Data Acquisition board model may change at any moment, providing the same or better features than those required for the unit.
4 BIEV/CCSOF. Computer Control +Data Acquisition+Data Management Software:
 The three softwares are part of the SCADA system.
 Compatible with the industry standards.
 Flexible, open and multicontrol software, developed with actual windows graphic systems, acting simultaneously on all process parameters.
 Management, processing, comparison and storage of data.
 Sampling velocity up to 250 KS/s (kilo samples per second).
 Calibration system for the sensors involved in the process.
 It allows the registration of the alarms state and the graphic representation in real time.
 Open software, allowing the teacher to modify texts, instructions. Teacher’s and student’s passwords to facilitate the teacher’s control on the student, and
 allowing the access to different work levels.
 This unit allows the 30 students of the classroom to visualize simultaneously all the results and the manipulation of the unit, during the process, by using
 a projector or an electronic whiteboard.
5 Cables and Accessories, for normal operation.
6 Manuals:
 This unit is supplied with 8 manuals: Required Services, Assembly and Installation, Interface and Control Software, Starting-up, Safety, Maintenance,
 Calibration & Practices Manuals.
                                                                              8                                                                www.edibon.com
                                                TENDER SPECIFICATIONS (for optional items)
                                                    a) Technical and Vocational Education configuration
 7 BIEV/ICAI. Interactive Computer Aided Instruction Software System.
   This complete software package consists of an Instructor Software (EDIBON Classroom Manager - ECM-SOF) totally integrated with the Student Software
   (EDIBON Student Labsoft - ESL-SOF). Both are interconnected so that the teacher knows at any moment what is the theoretical and practical knowledge
   of the students.
   - ECM-SOF. EDIBON Classroom Manager (Instructor Software).
   ECM-SOF is the application that allows the Instructor to register students, manage and assign tasks for workgroups, create own content to carry out
   Practical Exercises, choose one of the evaluation methods to check the Student knowledge and monitor the progression related to the planned tasks for
   individual students, workgroups, units, etc...so the teacher can know in real time the level of understanding of any student in the classroom.
   Innovative features:
   • User Data Base Management.
   • Administration and assignment of Workgroup, Task and Training sessions.
   • Creation and Integration of Practical Exercises and Multimedia Resources.
   • Custom Design of Evaluation Methods.
   • Creation and assignment of Formulas & Equations.
   • Equation System Solver Engine.
   • Updatable Contents.
   • Report generation, User Progression Monitoring and Statistics.
   - ESL-SOF. EDIBON Student Labsoft (Student Software).
   ESL-SOF is the application addressed to the Students that helps them to understand theoretical concepts by means of practical exercises and to prove their
   knowledge and progression by performing tests and calculations in addition to Multimedia Resources. Default planned tasks and an Open workgroup are
   provided by EDIBON to allow the students start working from the first session. Reports and statistics are available to know their progression at any time,
   as well as explanations for every exercise to reinforce the theoretically acquired technical knowledge.
   Innovative features:
   • Student Log-In & Self-Registration.
   • Existing Tasks checking & Monitoring.
   • Default contents & scheduled tasks available to be used from the first session.
   • Practical Exercises accomplishment by following the Manual provided by EDIBON.
   • Evaluation Methods to prove your knowledge and progression.
   • Test self-correction.
   • Calculations computing and plotting.
   • Equation System Solver Engine.
   • User Monitoring Learning & Printable Reports.
   • Multimedia-Supported auxiliary resources.
                                                               b) Multipost Expansions options
 8 MINI ESN. EDIBON Mini Scada-Net System for being used with EDIBON Teaching Units.
   MINI ESN. EDIBON Mini Scada-Net System allows up to 30 students to work with a Teaching Unit in any laboratory, simultaneously.
   The MINI ESN system consists of the adaptation of any EDIBON Computer Controlled Unit with SCADA integrated in a local network.
   This system allows to view/control the unit remotely, from any computer integrated in the local net (in the classroom), through the main computer
   connected to the unit.
   Main characteristics:
   - It allows up to 30 students to work simultaneously with the EDIBON Computer Controlled Unit with SCADA, connected in a local net.
   - Open Control + Multicontrol + Real Time Control + Multi Student Post.
   - Instructor controls and explains to all students at the same time.
   - Any user/student can work doing "real time" control/multicontrol and visualisation.
   - Instructor can see in the computer what any user/student is doing in the unit.
   - Continuous communication between the instructor and all the users/students connected.
   Main advantages:
   - It allows an easier and quicker understanding.
   - This system allows you can save time and cost.
   - Future expansions with more EDIBON Units.
   The system basically will consist of:
   This system is used with a Computer Controlled Unit.
   - Instructor’s computer.
   - Students’ computers.
   - Local Network.
   - Unit-Control Interface adaptation.
   - Unit Software adaptation.
   - Webcam.
   - MINI ESN Software to control the whole system.
   - Cables and accessories required for a normal operation.
* Specifications subject to change without previous notice, due to the convenience of improvement of the product.
                                                                                      REPRESENTATIVE:
  C/ Julio Cervera, 10-12-14. Móstoles Tecnológico.
  28935 MÓSTOLES. (Madrid). ESPAÑA - SPAIN.
  Tel.: 34-91-6199363 Fax: 34-91-6198647
  E-mail: edibon@edibon.com Web: www.edibon.com
  Edition: ED01/20
  Date: April/2020