0% found this document useful (0 votes)
61 views68 pages

Breeze General Catalogue - 2022

This document provides an introduction to Breeze Industrial Ventilation Joint Stock Company, which was established in Vietnam in 2018 to import, manufacture, assemble, and distribute industrial fans. It summarizes the company's history and product lines, which include axial fans, centrifugal fans, cabinet fans, wall fans, and more. Certifications and standards that products are manufactured according to are also listed.

Uploaded by

eep saepudin
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
61 views68 pages

Breeze General Catalogue - 2022

This document provides an introduction to Breeze Industrial Ventilation Joint Stock Company, which was established in Vietnam in 2018 to import, manufacture, assemble, and distribute industrial fans. It summarizes the company's history and product lines, which include axial fans, centrifugal fans, cabinet fans, wall fans, and more. Certifications and standards that products are manufactured according to are also listed.

Uploaded by

eep saepudin
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 68

We bring better air to life

The
Product Catalogue

Technology from
Since 1928 in London Made in United Kingdom
Company Introduction
We bring better air to life

About Us
In 1928, The London Fan and Motor Company was formed by Mr. G. H. Webber and has been owned since by
the Webber family. During the early years the company began to manufacture industrial propeller fans and
electric motors under the trade name Breeza Fan and moved from Charlotte Street in the West End of London
to a larger factory in Alfred Place off Tottenham Court Road.
After the Second World War the company moved to Park Road, North Acton and then to the present premises in
1965. The post-war years saw the development of the company into a wide range of ventilating equipment and
industrial fans brought about mainly by the take-over of a number of other businesses in the fan trade, one of
which became Breezax Impellers Ltd. The company discontinued the manufacture of electric motors and its
name changed to The London Fan Company Ltd.
Having built a reputation for quality fan manufacture and innovative design, the company continues to expand
its manufacturing base to ensure worldwide availability of industrial fans and Breezax impellers under the
leadership of Andrew Webber. With investment in the development of new products, the company looks to a
successful future in an evolving global market.
In 1990, The London Fan Company established Breeza Fan in USA.
In 2001, Breezax Technology Pte Ltd established in Singapore which is representative of London Fan
Company products and Breezax Impellers in United Kingdom for Asia Pacific Region.
In 2018, Breeze Industrial Ventilation Joint Stock Company was established in Vietnam. We are authorized
from Breezax Technology Pte Ltd to import, manufacture/assemble and distribute Breeze Fan in Vietnam for 04
countries in Southeast Asia.
Territory:
Ÿ Socialist Republic of Vietnam,
Ÿ Kingdom of Cambodia,
Ÿ Laos People's Democratic Republic,
Ÿ Myanmar (Burma).
The products range by Breeze Industrial Ventilation Joint Stock Company is manufactured/assembled and
imported in accordance with Standard and Technology of London Fan in United Kingdom to the following these
types:

Ÿ Axial Flow Fan Ÿ Centrifugal Fan (SISW, DIDW)


Ÿ Smoke Extract Axial Fan Ÿ Cabinet Centrifugal Fan (SISW, DIDW)
Ÿ Car Park Jet Fan Ÿ Inline Centrifugal Fan
Ÿ Bifurcated Axial Fan Ÿ Silent Inline Fan
Ÿ Rooftop Axial Fan Ÿ Mixed Flow Inline Fan
Ÿ Plate Mounted Axial Fan Ÿ Ceiling Mounted Fan
Ÿ Plate Mounted Wall Fan Ÿ Wall Mounted Fan
Ÿ The ATEX Explosion Proof Fans and Motors Ÿ The Components
Ÿ Etc.

Our products are manufactured and followed according to technology and the worldwide accepted standard
and Vietnam as ISO 9001:2015, BS 848 part 1 and part 2:1985, ISO 5801, ISO 5136, ISO 13347 part 2, EN
12101-3, ATEX and IEC60335 (QCVN 04:2009/BKHCN and TCVN 5699-2-80:2007).

www.breeze.com.vn | breezefans@breeze.com.vn 02
Certifications
We bring better air to life

www.breeze.com.vn | breezefans@breeze.com.vn 03
Product Overview
We bring better air to life

Axial Flow Fan

LC Series - Axial Flow Fan LCS Series - Smoke Extract Axial Fan LCF Series - Explosion Proof Axial Fan
v Range Size: 315mm - 1600mm v Range Size: 315mm - 1600mm v Range Size: 315mm - 1250mm
v Air Flow: 195.000 m3/h v Air Flow: 195.000 m3/h v Air Flow: 125.000 m3/h
v Pressure: 1.500 Pa v Pressure: 1.500 Pa v Pressure: 1.500 Pa
v Material: Mild steel with epoxy coated or requested. v Material: Mild steel with epoxy coated or requested. v Material: Mild steel with epoxy coated or requested.
v Motor: IP55, Class F v Motor: IP55, Class H v Motor: IP55 or IP66, Class F

JFLC Series - Car Park Jet Fan RSC Series - Rooftop Axial Fan BN Series - Bifurcated Axial Fan
v Range Size: 315mm - 450mm v Range Size: 315mm - 1600mm v Range Size: 315mm - 1250mm
v Air Flow: 12.000 m3/h v Air Flow: 195.000 m3/h v Air Flow: 125.000 m3/h
v Thrust Force: 84 N v Pressure: 1.500 Pa v Pressure: 1.500 Pa
v Material: Hot galvanized steel. v Material: Mild steel with epoxy coated or requested. v Material: Mild steel with epoxy coated or requested.
v Motor: IP55, Class F or H v Motor: IP55, Class F v Motor: IP55, Class F

PA Series - Plate Mounted Axial Fan PAF Series - ATEX Plate Mounted Axial Fan AWF Series - Industrial Wall Fan
v Range Size: 315mm - 1000mm v Range Size: 315mm - 1000mm Belt Driven
v Air Flow: 90.000 m3/h v Air Flow: 90.000 m3/h v Range Size: 750mm - 1250mm
v Pressure: 1.000 Pa v Pressure: 1.000 Pa v Air Flow: 45.000 m3/h
v Material: Mild steel with epoxy coated or requested. v Material: Mild steel with epoxy coated or requested. v Pressure: 50 Pa
v Motor: IP55, Class F v Motor: IP55 or IP66, Class F v Motor: IP 55, Class F

Single Inlet Centrifugal Fan

FCS Series - Forward Curve (SISW) BCS Series - Backward Curve (SISW) PF Series - Plug Fan
Belt Driven Belt Driven v Range Size: 250mm - 1000mm
v Range Size: 280mm - 1000mm v Range Size: 280mm - 1400mm v Air Flow: 70.000 m3/h
v Air Flow: 70.000 m3/h v Air Flow: 100.000 m3/h v Pressure: 3.000 Pa
v Pressure: 1.500 Pa v Pressure: 3.000 Pa v Material: Mild steel with epoxy coated.
v Material: Hot galvanized steel or requested. v Material: Hot galvanized steel or requested. v Motor: IP55, Class F
v Motor: IP55, Class F v Motor: IP55, Class F

www.breeze.com.vn | breezefans@breeze.com.vn 04
Product Overview
We bring better air to life

Double Inlet Centrifugal Fan | Cabinet Centrifugal Fan

FCD Series - Forward Curve (DIDW) BCD Series - Backward Curve (DIDW) KBB/KBB-F Series - Backward Curve (DIDW)
Belt Driven Belt Driven Cabinet Fan - Belt Driven
v Range Size: 200mm - 1000mm v Range Size: 200mm - 1250mm v Range Size: 200mm - 1250mm
v Air Flow: 90.000 m3/h v Air Flow: 120.000 m3/h v Air Flow: 120.000 m3/h
v Pressure: 1.500 Pa v Pressure: 3.000 Pa v Pressure: 3.000 Pa
v Material: Hot galvanized steel. v Material: Hot galvanized steel or requested. v Material: Hot galvanized steel or requested.
v Motor: IP55, Class F v Motor: IP55, Class F v Motor: IP55, Class F

KBF/KBF-F Series - Forward Curve (DIDW) KBP Series - Backward Curve (SISW) CDF/CDFS Series - Inline Centrifugal Fan
Cabinet Fan - Belt Driven Cabinet Plug Fan - Direct Driven Direct Driven
v Range Size: 200mm - 1000mm v Range Size: 250mm - 1000mm v Range Size: 200mm - 500mm
v Air Flow: 90.000 m3/h v Air Flow: 70.000 m3/h v Air Flow: 16.000 m3/h
v Pressure: 1.500 Pa v Pressure: 3.000 Pa v Pressure: 850 Pa
v Material: Hot galvanized steel. v Material: Hot galvanized steel. v Material: Hot galvanized steel.
v Motor: IP55, Class F v Motor: IP55, Class F v Motor: IP 55, Class F

Domestic Fan

AWS Series - Plate Mounted Wall Fan DVS Series - Silent Inline Fan MFD Series - Mixed Flow Inline Fan
v Range size: 250mm - 630mm v Range size: 100mm - 250mm v Range size: 100mm - 250mm
v Air Flow: 13.000 m3/h v Air Flow: 3.000 m3/h v Air Flow: 1.500 m3/h
v Pressure: 250 Pa v Pressure: 480 Pa v Pressure: 550 Pa
v Material: Plate steel with powder coated. v Material: Stainless steel. v Material: ABS polymer.
v Motor: IP 54, Class F v Motor: IP 44, Class B v Motor: IP 44, Class B

CMD/CPD Series - Ceiling Mounted Fan AWC Series - Wall Mounted Fan Breezax/Breezaxmax Impeller
v Range size: 100mm - 150mm v Range size: 150mm - 300mm v Range size: 250mm - 1600mm
v Air Flow: 330 m3/h v Air Flow: 1.200 m3/h v Material: ALU Blade
v Material: Full ABS plastic or Half metal + ABS. v Material: Full ABS plastic. GRP Blade
v Motor: IP 44, Class B v Motor: IP 44, Class B GRN Blade

www.breeze.com.vn | breezefans@breeze.com.vn 05
Axial Flow Fan
LC Series
We bring better air to life

Fan Code
LC 500 4 10B 20o
Pitch Angle
Number of Blades
Blade Type:
Ÿ B blade
Ÿ TXA blade
Ÿ C blade

Motor Poles
Diameter of Impeller
Fan Type

Description

Axial fans offer you a complete range of fan system and wide options of accessories such as impellers and
hubs to meet all kinds of applications and demands. The impeller of axial fans offer high efficiency up to 80%
or even higher.

Advanced Design of Straightening Stator Vanes and Ogive for Axial impellers:
With world’s leading Computational Fluid Design (CFD), axial fan has developed advanced straightening
stator vanes and ogives for axial impellers. As the figur shows, with straightening stator vanes and ogive,
turbulence in front of impeller has been greatly reduced, airflow becomes more stable and the efficacy can be
improved up to 8%.

Notes:
1. For detail, please see the fan performance curve or contact with Breeze Industrial Ventilation JSC.
2. Special or other size of air outlet direction, please negotiate with Breeze Industrial Ventilation JSC.

www.breeze.com.vn | breezefans@breeze.com.vn 06
Axial Flow Fan
LC Series
We bring better air to life

General Information
3
The performance range is from 500 m /h up to This way, the system produces an excellent
3
195.000 m /h, static pressure up to 1.500 Pa. High airstream profile and 2,7 to 3 times the pressure of a
pressure is possible on two-stage fans. single stage version.
Fan type: All parts of the multi stage version can be taken from
Ÿ SC Series: Short Cased Axial Flow Fan. the single stage fan and therefore can be produced at
Ÿ LC Series: Long Cased Axial Flow Fan.
a low cost. Each stage has its own seperate motor. If
one stage fails or is switched off, the second stage
Ÿ LCS Series: Smoke Extract Axial Fan.
still produces 65% of the air volume, while
Ÿ LCF Series: Explosion Proof Axial Fan.
consuming only 40 % of the energy. This system is
Ÿ CRLC Series: Two-stage Axial Fan. ideal for exhausting in carpark buildings. It works in
Ÿ CRLCS Series: Smoke Extract Two-stage Axial accordance to the regulations for carpark exhaust
Fan. systems in United Kingdom and other countries,
Construction Information which require two independent stages, so that the
fan will still be operating in case of a failure of one
Axial series are mainly constructed of casing,
stage. The airstream of the first stage will
impeller, motor and other accessories.
automatically turn the impeller of the switched off
Casing second stage in the opposite direction, so that it
Fan sizes are from 315mm to 1600mm diameter. supports the airflow instead of disturbing it. This also
All casings and motor mounting are made of mild saves energy compared to similar systems. Besides,
steel, all steel parts are epoxy coated after the impeller is already rotating in the right direction
manufacturing, thickness from 2.0mm to 6.0mm when the second stage is switched on. As another
upon diameter. advantage, this is an inexpensive way of adjusting
Casing flanges are rolled, the pitch circles of holes the air volume.
are in accordance to BS 6339 and ISO 6580. These are designed a two-stage axial flow fan:
Material option available: Ÿ Stage 1: Right hand blade

Ÿ Galvanized steel. Ÿ Stage 2: Left hand blade

Ÿ Hot dip galvanized after manufacturing. Airflow


Ÿ Stainless steel: 304 or 316L
Ÿ Requested.
Casings are completed with an externally mounted
terminal box which is prewired from the motor
terminal box, ensuring ease of installation at site.
Two-stage Axial Flow Fan
Two-stage axial flow fans, in series, counter rotating
for high pressures or for carpark application.
The system with just 2 counter rotating, in series axial
Stage 1 Stage 2
flow fans, static pressures up to nearly 2.500 Pa can (Higher blade angle) (Lower blade angle)
be achieved. The two-stage unit consists of 2 or
more counter rotating single stage in series with left For example:
hand and right hand blades, without guide vane. The Fan ref LC1000/4/12TXA/ALU/17.5o/15o
o
spin of the first stage is transformed into an additional Ÿ Stage 1 is 17.5
o
static pressure by the following stage. Ÿ Stage 2 is 15

www.breeze.com.vn | breezefans@breeze.com.vn 07
Axial Flow Fan
LC Series
We bring better air to life

Smoke Extract Operation


The LCS series are designed and tested to operate Blade materials are available in:
at standard temperatures as well as elevated Ÿ ALU: Standard
temperatures of 250oC/2 hours (H250) or 300oC/2 Ÿ GRP: Glass Reinforced Polypropylene
hours (H300), according to BS EN 12101-3/ISO
Ÿ GRN: Glass Reinforced Nylon
9001:2015.
Ÿ AST: Anti-static Nylon
Certificate number 0086-CPD-493412.
Operating temperature:
Manufacturing FLC EN 12101-3/ISO 9001:2008 o o
Ÿ ALU: -40 C + 200 C
o o
Explosion Proof Operation Ÿ GRP: -40 C + 70 C
o o
The LCF series are driven directly by an ATEX or Ÿ GRN: -40 C + 150 C
o o
IECEx certified motor. Single phases and three Ÿ AST: -30 C + 110 C
phases, IP55 or IP66, class F insulation, can be
Hub system:
frequency conversion motor.
Our range of axial fans has fully adjustable blades
For motors provided with PTC posistor sensors that
and there are 6 hub systems, as shown below:
should be connected to the protection system, the
type of sensor should be specified by the
Hub Type Number of Blades
customer/electrician.
The range covers Gases Group IIA, IIB & IIC and 110 5
most dust hazards. The Gas or Dust type must be 160 5,10
specified.
230 3,6,12
The impeller of LCF series are fitted with Anti-static
250 3,6,12
Nylon (AST) or Aluminum (AL blade) material if
required. 330 4,8,12,16
The LCF series are typically used for the purpose of 400 4,8,12,16
industrial ventilation, cooling and exhausting etc.
This product specially applies to Oil & Gas, Offshore Blade Design/Type:
Platform, Chemical, Petrochemical, Refinery and We have several options Blades Design as following:
Marine Industries etc.
Design Type Material Hub Series
Impeller Data
Breezax, S GRP/GRN 110, 160, 230
High efficiency aluminum aerofoil type. All units are
fitted with Breezax Impellers with Aluminum (ALU) Breezax, B ALU 110, 160, 230
blades. GRP or GRN blades can be fitted if required. Breezax, A GRP/GRN 110, 160, 230
Hubs are manufactured from fully die cast aluminum
Breezaxmax, A ALU/GRN 250, 330
alloy as standard.
Breezaxmax, T ALU 250, 330
The blades are with adjustable pitch angle to
optimize the dutypoint. The solidity varies for a wider Breezaxmax, C ALU/GRP 400
range of performance.
Balance:
The impellers are statically and dynamically
balanced on precision machines according to ISO
1940 with G2.5mm/s quality standard.

www.breeze.com.vn | breezefans@breeze.com.vn 08
Axial Flow Fan
LC Series
We bring better air to life

Mounting and Airflow


All units are suitable for internal or external operation Arrows indicating correct rotating and direction of
at any installed angle. airflow are mounted on the outside of the fan case.
Airflow direction: These forms of running are as follows:
Ÿ Plan B as standard.
Ÿ Plan A can be supplied if required.

A AU B BU

Performance data Sound levels


The axial fans are produced by Breeze Fan base on All measurements of the sound that the fans
technology of London Fan company, a world famous generate have been taken strictly in accordance with
axial impeller manufacture which was set up in 1928. BS 848-2, test method 1 and ISO 13347-2 for
Fan performance and data of type selection program acoustic performance.
are approved by British Standard. Sound data are determined according to BS EN ISO
Ÿ Manufuactured under a certified ISO 9001:2015. 5136 – In-duct method.
Ÿ The performance is tested international standards Published sound power level spectra figures are
-12
by BS 848-1:1985 and ISO 5801. dBW with a reference of 10 Watt (1 Pico watt).
Ÿ Installation position D, i.e. ducted inlet and ducted The sound power levels shown on the fan curves are
outlet configuration. for inlet LwiA scale for installation type D: ducted
Ÿ All curves to a density of
3 o
= 1,2 kg/m , at 20 C. inlet, ducted outlet. Ratings include the effects of
ducted end correction.
Selection Program The sound pressure level at the inlet at 1m distance
Full details are available on our selection program: in low reflection can be obtained by deducting 11dB
Breeze Fan or London Fan. from the sound power level at the inlet side. The
sound pressure difference from 1m to distance d is
The selection program is convenient, simple,
obtained as follows:
intelligent. It is easy to choose suitable fans, provide
and print out all data to confirm the result of choice. LpiA = 10 * log (1/d)
You can transfer these data to consultants and Where: d = distance from fan in meters.
designers. Please note that reflections and room characteristics
Please contact our sale department or login as well as natural frequencies influence the size of
http://www.breeze.com.vn for selection program. the sound pressure level differently

www.breeze.com.vn | breezefans@breeze.com.vn 09
Axial Flow Fan
LC Series
We bring better air to life

Motor Data
Motors incorporated are TEFC (Total Enclosed Fan Available specific for your project requirements such
Cooled) and airstream rated to IEC 34-1. as:
Standard motors are protected to IP55 with Class F Ÿ 220-240V / 380-415V-50Hz.
insulation. Operating temperature is from -20oC to Ÿ 60Hz: specific to your voltage requirements.
o
+50 C as standard, fans for operation beyond these Ÿ IE1, IE2, IE3 and IE4 Efficiency Classes.
limits are also available.
Ÿ 2-speed (Full/Half and Full/Two Thirds).
Motors are suitable for speed control by frequency
Ÿ High temperature motor and double speeds motor
inverter, subject to fan selection.
(Class H): 250oC/2hrs or 300oC/2hrs or requested.

Fan Laws
Speed Change - Constant Size Change - Constant Density Change - Constant
Size - Constant Density Speed - Constant Density Speed - Constant Size
)3
Ÿ Air Volume ~
Rotation Speed
~ Ÿ Air Volume ~
(IMP. Diameter)
~ Ÿ Air Volume = No change

3
V2 n2 V2 D2
= = V = Constant
V1 n1 V1 D1

2 2
Ÿ Pressure ~
(Rotation
~ Speed) Ÿ Pressure ~
(IMP.
~ Diameter) Ÿ Pressure ~
Density
~
2 2 2
p1 n1 V1 p1 D1 p1 1 T2
= = = = =
p2 n2 V2 p2 D2 p2 2 T1

Speed)3
5
Ÿ Abs. Power ~
(Rotation
~ Ÿ Abs. Power ~
~(IMP. Diameter) Ÿ Abs. Power ~
~Density
3 3 5
P1 n1 V1 P1 D1 P1 1 T2
= = = = =
P2 n2 V2 P2 D2 P2 2 T1

Noise: Whereby: Ÿ V = Air Volume (m /s)


3

D2 n2 Ÿ D = Impeller diameter (mm)


N2 - N1 = 50 log10 * + 50 log10 *
D1 n1 Ÿ P = Absorbed power (kW)

Pressure Ÿ N = Noise
Ÿ n = Rotation speed (rpm)
Ÿ Dynamic Pressure (Pa)
2
pd = *v Ÿ pt = Total pressure (Pa)
2
Ÿ pst = Static pressure (Pa)
Ÿ Total Pressure (Pa) pt = pst + pd Ÿ pd = Dynamic pressure (Pa)
Ÿ = Air density (kg/m3),
Ÿ Air Velocity (m/s) V*4
v = 2
standard is 1.2kg/m3
πD
Ÿ v = Air velocity (m/s)
Absorbed Power 3
V (m /s) * pt (Pa) Ÿ = Efficiency (%)
P = ( % * 10
) kW Ÿ π 3.14
=

www.breeze.com.vn | breezefans@breeze.com.vn 10
Axial Flow Fan
LC Series
We bring better air to life

PERFORMANCE CURVES
Fan tested in accordance with BS848:Part1:1985 and ISO 5801. There is a policy of continous product improvement, and the right is

MORE DETAILED CURVES AVAILABLE ON REQUEST


Ins wg
2000 8.0
Dia mm
6.0
400 - 1800 @ 960rpm
1000 4.0
630 - 1800 @ 720rpm
800 3.0

600
2.0

400
FAN STATIC PRESSURE

1.0
200 0.8

0.6

100 0.4
80 0.3
60
0.2
40

0.1
20
0.1 0.2 0.3 0.4 0.6 0.8 1 2 3 4 6 8 10 20 30 40 60 80 100 m3/s
VOLUME
0.25 0.5 1 1.5 2 4 6 8 12 16 20 40 80 120 160 ftm3/s
(x 1000)

Ins wg
reserved to revise product information without prior notice.

2000 8.0
Dia mm

315 - 800 @ 2880rpm 6.0

1000 315 - 1400 @ 1440rpm 4.0


800 3.0

600
2.0

400
FAN STATIC PRESSURE

1.0
200 0.8

0.6

100 0.4
80 0.3
60
0.2
40

0.1
20
0.1 0.2 0.3 0.4 0.6 0.8 1 2 3 4 6 8 10 20 30 40 60 80 100 m3/s
VOLUME
0.25 0.5 1 1.5 2 4 6 8 12 16 20 40 80 120 160 ftm3/s

www.breeze.com.vn | breezefans@breeze.com.vn 11
Axial Flow Fan
LC Series
We bring better air to life

Dimension Information D C

B
A
G-nos
H-dia

Model Motor Frame A B C D G-nos H-Dia Weight (kg)

LC 315 D71-90 315 395 400 366 8 10 45

LC 355 D71-90 355 435 400 405 8 12 50

LC 400 D71-100 400 485 400 450 8 12 55

LC 450 D71-112 450 530 400 497 8 12 80

LC 500 D71-112 500 585 500 550 12 12 90

LC 560 D71-112 560 660 500 629 12 12 100

LC 630 D71-112 630 730 600 698 12 12 120

LC 710 D100-112 710 810 600 775 16 12 150

D132 190

LC 800 D100-112 800 900 700 861 16 14 180

D132 220

LC 900 D100-112 900 1000 700 960 16 14 200

D132-160 250-310

LC 1000 D132 1000 1100 850 1060 16 14 350

D160-180 420-500

LC 1120 D160-180 1120 1220 1000 1192 20 18 560-670

D200 750

LC 1250 D160-180 1250 1350 1000 1337 20 18 610-720

D200 800

LC 1400 D160-200 1400 1500 1000 1474 20 18 750-950

D225-250 1200 1250-1450

LC 1600 D160-200 1600 1700 1000 1675 24 18 900-1100

D225-250 1200 1350-1550

www.breeze.com.vn | breezefans@breeze.com.vn 12
Axial Flow Fan
LC Series
We bring better air to life

Accessories
Size A B C D O Wt (kg)
315 365 25 220 50 12 0.5
355 405 25 240 50 12 0.8
CENTRE OF FAN 400 450 25 260 50 12 1.0
450 500 25 280 50 12 1.2
500 550 25 315 60 12 1.5
560 610 25 345 60 14 2.0
C
630 680 30 400 75 14 2.5
2 NOS. O 710 785 30 450 75 14 3.0
B B 800 875 30 500 75 14 5.5
A D
900 975 30 580 75 18 8.0
1000 1075 30 630 75 18 10.0
1120 1220 30 690 75 18 12.0
1250 1350 50 737 95 20 14.0
All dimensions in mm.

Size A B C D E Wt (kg)
315 315 395 125 420 2.0 3.0
355 355 435 125 470 2.0 3.5
C

400 400 485 135 520 2.0 4.0


E

450 450 530 135 570 2.0 4.5


Elevation cone inlet

500 500 585 150 630 2.0 5.0


560 560 660 150 710 2.0 6.0
630 630 730 150 780 3.0 8.0
D
B
A

710 710 810 200 860 3.0 10.0


800 800 900 200 980 3.0 12.0
900 900 1000 250 1080 3.0 18.0
1000 1000 1100 250 1200 3.0 25.0
1120 1120 1220 300 1320 3.0 30.0
1250 1250 1350 300 1450 3.0 35.0
All dimensions in mm.

Size G.nos H.Dia J F K L Wt (kg)


315 8 10 355 395 315 50 2.0
F L 355 8 12 395 435 355 50 2.5
G.nos x H.dia
400 8 12 450 485 400 50 3.0
450 8 12 500 530 450 50 3.5
500 12 12 560 585 500 60 4.0
560 12 12 620 660 560 60 4.5
K DIA.

630 12 12 690 730 630 60 5.0


710 16 12 770 810 710 60 6.0
800 16 14 860 900 800 70 7.0
900 16 14 970 1000 900 70 8.0
1000 16 14 1070 1100 1000 70 9.0
1120 20 18 1190 1220 1120 70 10.0
1250 20 18 1320 1350 1250 70 12.0
All dimensions in mm.
* Dimensions shown are approximate only. The details please contact local sales office for more information.

www.breeze.com.vn | breezefans@breeze.com.vn 13
Axial Flow Fan
LC Series
We bring better air to life

Type B & C Silencers


A

Tapped hole to
match fan flange

OD
PC

ID
POD - TYPE C ONLY

Attachable Feet
(Optional Extra) 2 Holes in each foot
Hole Spacing

The above silencers give the approximate dB(A) reductions:


B Type diameter length -7 to 10 dB(A)
C Type 1 diameter length -12 to 15 dB(A)
For full acoustic details contact with London Fan or Breeze Industrial Ventilation Joint Stock
Company.

Dimensions and Weights

mm Dimension (mm) Weight (kg)

Mounting Foot A Length B C


Size (D) OD No of PCD Thread Holes
Holes
Dia Spacing 1D 2D 1D 2D 1D 2D

280 385 4 320 M8 10 230 280 560 9 14 - -


315 415 8 355 M8 10 265 315 630 10 17 13 19
355 455 8 395 M8 10 305 355 710 12 20 15 24
400 500 8 450 M10 10 350 400 800 15 25 18 30
450 600 8 500 M10 10 400 450 900 20 33 24 39
500 650 12 560 M10 10 450 500 1000 25 41 29 48
560 710 12 620 M10 10 510 560 1120 30 50 35 58
630 780 12 690 M10 12 580 630 1260 35 61 42 72
710 860 16 770 M10 10 660 710 1420 44 76 53 90
800 1000 16 860 M10 12 750 800 1600 55 96 66 116
900 1100 16 970 M12 12 850 900 1800 70 129 84 150
1000 1200 16 1070 M12 12 950 1000 2000 82 157 100 182
1120 1320 20 1190 M12 16 1070 1120 2342 100 211 118 247
1250 1450 20 1320 M12 16 1150 1250 2602 127 266 147 306
1400 1600 20 1470 M12 16 1300 1400 2902 199 399 220 453
1600 1800 24 1680 M16 16 1500 1600 3302 311 637 362 739

All dimensions in mm.

* Dimensions shown are approximate only. The details please contact local sales office for more information.

www.breeze.com.vn | breezefans@breeze.com.vn 14
Axial Flow Fan
LC Series
We bring better air to life

Installation Guide
Equipment foot Equipment foot Building contruction Building contruction
or mounting bra or mounting bra

1 2
1 2

Equipment or hang Equipment or hang

Building contruction Building contruction


Equipment foot Equipment foot
or mounting bra or mounting bra
Turn/Adjust
Bolt to Reach

3 4 3 4
Turn/Adjust
Bolt to Reach
Equipment or hang

Equipment or hang

Mounting Isolators Hanger Isolators


Flexible Connection

Outlet Duct
Airflow

Spring Isolator Building Construction

Fig 01. Mounting type


Building Contruction Building Contruction

Adjust nut to reach Spring Isolator Adjust nut to reach Spring Isolator

Flexible Connection

Outlet Duct
Airflow

Stud
U-steel support
U-steel support

Fig 02. Hanging type

www.breeze.com.vn | breezefans@breeze.com.vn 15
Bifurcated Axial Fan
BN Series
We bring better air to life

Fan Code
O
BN 500 4 10B 20

Pitch Angle
Number of Blades
and Blade Type
Motor Poles

Diameter of Impeller

Bifurcated Axial Fan

General Information Impeller Data

This range of fans is designed specifically for High efficiency aluminum aerofoil type. All units are
extracting contaminated air, operating in corrosive, fitted with Breezax Impellers with Aluminum (ALU)
hot, dusty, or hazardous conditions. The impeller is blades.
directly coupled to the motor which is enclosed within Hubs are manufactured from fully die cast aluminum
its own compartment outside of the airstream. alloy as standard.

Construction Information The blades are with adjustable pitch angle to


optimize the dutypoint. The solidity varies for a wider
Bifurcated Axial series are mainly constructed of
range of performance.
casing, impeller, motor and other accessories.
Balance:
Casing
The impellers are statically and dynamically
Fan sizes are from 315mm to 1600mm diameter.
balanced on precision machines according to ISO
The performance range is from 500 m3/h up to
1940 with G2.5mm/s quality standard.
195.000 m3/h, pressure up to 1.500 Pa.
Motor Data
The casings and motor mounting are made of mild
steel, all steel parts are epoxy coated after Standard three of single phase totally enclosed fan
manufacturing, thickness from 2.0mm to 6.0mm ventilated design. All comply with BS 5000 part 10
upon diameter. and part 99 and relevant parts of BS 4999. Suitable
Material option available: for mounting in vertical of horizontal plane.
Flameproof, dual speed, dust or weather protected
Ÿ Hot dip galvanized after manufacturing.
options are available in all sizes.
Ÿ Requested.
Performance Data
Temperature Range
o Full details are available on our selection program:
Standard temperature units up to 100 C continuous
Breeze Fan or London Fan.
operation. High temperature up to 200oC continuous
operation. Ÿ Manufuactured under a certified ISO 9001:2015.

Heat insulating material and an additional cooling fan Ÿ The performance is tested international standards

are fitted inside the motor compartment. Emergency by BS 848-1:1985 and ISO 5801.
o
Fume and Smoke Extract up to 300 C short duration. Please contact our sale department or login
Please consult The Breeze Fan for higher http://www.breeze.com.vn for selection program.
temperature applications.

www.breeze.com.vn | breezefans@breeze.com.vn 16
Bifurcated Axial Fan
BN Series
We bring better air to life

Sound levels Ancillaries


All measurements of the sound that the fans The standard range of ancillary items include:
generate have been taken strictly in accordance with matching flanges, flexible connectors, mounting feet
BS 848-2, test method 1 and ISO 13347-2 for and AV mounts. Anti back draught dampers, inlet
acoustic performance. cones and silencers are also available.

Dimension Information G Holes H dia. on I P.C.D ß


(Holes off centre) C

A
F

D E
All dimensions in mm. (Horizontal Mounting)

Motor G-nos Weight


Model
Frame
A B C D E F
H dia
ß (kg)

BN 315 D71-90 315 395 400 265 340 205 8 x 10 22.5 50

BN 355 D71-90 355 435 400 305 340 225 8 x 12 22.5 55

BN 400 D71-100 400 485 400 350 340 252 8 x 12 22.5 65

BN 450 D71-112 450 530 400 400 340 280 8 x 12 15 90

BN 500 D71-112 500 585 600 440 530 315 12 x 12 15 110

BN 560 D71-112 560 660 600 500 530 345 12 x 12 15 120

BN 630 D71-112 630 730 600 570 530 400 12 x 12 15 150

D100-112 710 810 700 650 630 450 16 x 12 11.25 180


BN 710
D132 220

D100-112 800 900 850 740 770 500 16 x 14 11.25 230


BN 800
D132 270

D100-112 900 1000 850 830 770 580 16 x 14 11.25 250


BN 900
D132-160 300-360

D132 1000 1100 850 930 900 630 16 x 14 11.25 420


BN 1000
D160-180 490-570

D160-180 1120 1220 1200 1050 1100 690 20 x 18 9 650-760


BN 1120
D200 850

D160-180 1250 1350 1200 1180 1100 750 20 x 18 9 710-820


BN 1250
D200 900

www.breeze.com.vn | breezefans@breeze.com.vn 17
Car Park Jet Fan
JFLC Series
We bring better air to life

Fan Code

JFLC 355 40 oC

Working Temperature
o o
250 C/2hrs or 300 C/2hrs

Diameter of Impeller

Car Park Jet Fan

General Information
Over the years, conventional ducted ventilation Therefore, in previous years, Jet Fan (or
system has established its standards and impulse/induction) ventilation system has emerged
functionally. Firstly, it has to effectively remove or as the most significant new solution available for car
dilute toxic gases from emission of vehicles and park design of the building industry. The benefits of
make sure that there are no packets of stagnant air. the system can be reaped not only by the car park
Secondly, in the event of a fire, it has to clear heat and owners, but also the users and designers. Jet Fan
smoke generated by fire as soon as possible for fire system has evolved from the longitudinal tunnel
fighting to be carried out after that. Other criteria that ventilation system that is mostly used in road tunnel
are desirable, though harder to be attained, are to system and has long been proven in safeguarding
create a smoke free clear path for Fire Service vehicular movement in confined spaces. Designed
personnel to enter for fighting the fire as well as for effective environmental and smoke control, the
protection for the public to escape. To achieve better Jet Fan system has been tried and tested in many car
result, conventional ducted system always demands parks throughout Europe and Middle East. A sketch
a larger space for ducting installation but this is of Jet Fan system is as follow:
difficult under constraint of a normally limited space
in car park.

Fress Air Motorized TYPICAL JET FAN SYSTEM Motorized Exhaust Air
intake Damper Damper discharge
louver (Optional) (Optional) louver
Fresh air though rump & openings

Silencer Silencer

Main Intake Fan Main Intake Fan


20%
Silencer Silencer

Jet Fan Air Path


80% Air Path Air Path (Hot)
Motorized
Damper

Motorized
Damper
Air Path

Air Path

Air Path Air Path


CO CO
sensor sensor Air Path
(Normal)

Fresh Air discharge louver

www.breeze.com.vn | breezefans@breeze.com.vn 18
Car Park Jet Fan
JFLC Series
We bring better air to life

Casing Motor Data


Fan sizes are from 315mm to 450mm diameter. The motors fitted two-speed dahlander motor (full
The casings are made from mild steel with epoxy and half speed) with protection class of IP55 and
coated or galvanized steel and hot dip galvanized Class H insulation which are capable of with standing
o o
can be provided upon request. Solid steel terminal up to 250 C/ 2 hours or 300 C/ 2 hours upon request
box with a rating at IP55 is fitted on the external part in accordance to BS EN 12101-3. The motors are
of the fan case. manufactured in accordance to specific standards
that include:
Impeller Data Ÿ Good internal clearance in bearings lubricated with
High efficiency aluminum aerofoil type. All units are extra high temperature grease.
fitted with Breezax Impellers with Aluminum (ALU) Ÿ Double insulated terminal leads;
blades.
Ÿ Double varnish system for winding crown etc.
The performance is tested international standards by
Motors are suitable for speed control by frequency
BS 848-1:1985 and ISO 5801.
inverter, subject to fan selection.
All curves to a density of = 1,2 kg/m3, at 20oC.
Balance: Silencer (Sound Attenuator)
The impellers are statically and dynamically The inlet & outlet silencer are designed with an
balanced on precision machines according to ISO aerodynamically shaped inlet cone (bell mouth)
1940 with G2.5mm/s quality standard. which is welded to the outer case of the silencer.
Perforated galvanized steel is fitted in the inner side
What is Jet Fan Ventilation System? of casing and non-flammable rock wool or fiberglass
A Jet Fan or impulse ventilation system is an is inserted beneath for sound attenuation purpose.
alternative to the conventional ducted system and Theoretically, any desirable sound level can be
overcomes the shortcomings of ducted system. A Jet achieved with the proper length of the silencer but
Fan comprises a ahigh velocity axial fan with both site constraints may limit the choice. The option to
inlet and outlet attenuator as well as the flow include a deflector louver at the outlet of fan silencer
distribution control device. The velocity and volume can be necessary to divert the air stream from Jet
of the impulse Jet Fan airflow are the decisive Fan should the obstruction to airflow by beams or
parameters which are represented by its thrust at other M&E services is considered significant.
discharge. The thrust of the Jet Fan is also a
determining criteria to the number of impulse Jet
Fans required in this ventilation system.

0 1.05 2.1 3.15 4.2 5.25 6.3 7


velocity (m/s)

Figure A: Top view of velocity profile of jet fan

www.breeze.com.vn | breezefans@breeze.com.vn 19
Car Park Jet Fan
JFLC Series
We bring better air to life

As we cam see the amount of air movement induced by the thrust of the Jet Fan is many times the airflow
through the Jet Fan. This property enables the Jet Fan to replace conventional ducting in car park ventilation
though the main exhaust/fresh air fans remain.

0 1.05 2.1 3.15 4.2 5.25 6.3 7


velocity (m/s)
Figure B: Side view of velocity profile of jet fan

The velocity profile of a Jet Fan can be numerically determined through Computational Fluid Dynamic (CFD)
analysis with the boundary conditions (proximity to floor slab, beam obstruction, etc) as stated. The velocity
profile of the most common 450mm diameter axial type of Jet Fan, operating at high speed under a ceiling slab is
as follow:

1.0m/s 0.5m/s 0.3m/s


Jet Fan

This Jet Fan typically produces a thrust force of 84N (Newtons) at high speed. Some modification to impeller
blade or its pitch angle can result in higher thrust force but at the expense of higher noise level and power
consumption. The higher the thrust force, the further and wider the air throw of Jet Fan can reach and thus
covering a larger floor area. Larger fan has higher thrust but designer of car park ventilation system has to
consider the size of fan as well as the head room requirement by relevant authorities. It is also favorable to keep
minimum number of fans in a system as life safety feature in emergency mode.
The figure below shows a car park space of around 2,600m2 that is ventilated by Jet Fan system. It illustrates
only the fire mode operation of the system:

exhaustair
0,3m/s tair
aus
0.5m/s
s

1.0m/s 1.0m/s 0.5m/s 0.3m/s


m/

exh
0.3

dn

supply air
m/s
0.5

Sp Rier
15000 ELeetreel rlser
m/s
1.0

supply air

0.3m/s 0.3m/s
0.5m/s 0.5m/s
1.0m/s 1.0m/s
mocrbke
oarkinglct

www.breeze.com.vn | breezefans@breeze.com.vn 20
Car Park Jet Fan
JFLC Series
We bring better air to life

The Jet Fan are operating at high speed (fire mode) and a car in the middle in on fire. The main exhaust fans are
at the top right hand corner while the main supply air fans are at the left hand side. The bulk airflow created by the
main fans as well as the airflow induced by the Jet Fans will direct the smoke towards the exhaust point of the
system. The induced airflow also effectively helps to dilute the smoke & heat produced by the fire to keep toxicity
and temperature from reaching dangerous level.
The cross sectional view of Jet Fan installation shows its great range of air throw at fire mode if no or minimal
obstruction to airflow by beam or other M&E services exists:

9500 9500 7500 8000

F136/E F136/E F 136

3200
CAR PARKNG CAR PARKNG

800
250

2950
CAR PARKNG CAR PARKNG

800
2800
CAR PARKNG CAR PARKNG

Performance Parameters

Flow Rate Out. Velocity Thrust Motor A B C Lmax Noise


Model m3/h (m/s) Force (N) Power (kW) RPM Fan at 3m

5000/2500 16.72/8.36 24/6 1.1/0.28 2880/1440 58/41


JFLC 315 415 335 670 1675
5000 16.72 24 1.1 2880 58

7200/3600 20.08/10.12 40/10 1.7/0.34 2880/1440 62/46


JFLC 355 455 375 750 1875
7200 20.08 40 2.2 2880 62

9000/4500 19.7/9.79 60/15 2.2/0.37 2880/1440 63/49


JFLC 400 500 420 840 2100
9000 19.7 60 2.2 2880 63

12000/6000 21.05/10.64 84/21 3.3/0.66 2880/1440 68/51


JFLC 450 550 470 940 2350
12000 21.05 84 4.0 2880 68

All dimensions in mm.


Dimension Information
Overall Length L

Shutter
A

Airflow Airflow

B 25x25 Wiremesh
Silencer C Front View Silencer C TYPICAL END VIEW

www.breeze.com.vn | breezefans@breeze.com.vn 21
Rooftop Axial Fan
RSC Series
We bring better air to life

Fan Code
RSC 500 4 10B 20o

Pitch Angle
Number of Blades
and Blade Type

Motor Poles

Diameter of Impeller

Rooftop Axial Fan

Casing
Fan sizes are from 315mm to 1600mm diameter. Operating temperature:
The performance range is from 500 m3/h up to o
Ÿ ALU: -40 C + 200 C
o

3
195.000 m /h, pressure up to 1.500 Pa. o
Ÿ GRP: -40 C + 70 C
o

All casings and motor mounting are made of mild o


Ÿ GRN: -40 C + 150 C
o

steel, all steel parts are epoxy coated after o


Ÿ AST: -30 C + 110 C
o

manufacturing, thickness from 2.0mm to 6.0mm


Balance:
upon diameter.
The impellers are statically and dynamically
Roof cowl is made of aluminum or mild steel with
balanced on precision machines according to ISO
epoxy coated or stainless steel upon requested.
1940 with G2.5mm/s quality standard.
Roof base support and protection guard are epoxy
coated. Motor Data
Applications: Motors incorporated are TEFC (Total Enclosed Fan
Designed for roof installation, and suitable for: Cooled) and airstream rated to IEC 34-1.

General ventilation in factory and warehouse, Standard motors are protected to IP55 with Class F
buildings, shops and industry. insulation. Operating temperature is from -20oC to
o
+50 C as standard, fans for operation beyond these
Ÿ Roof ventilation (Aluminum roof).
limits are also available.
Ÿ Smoke extraction vertical discharge.
Motors are suitable for speed control by frequency
Temperature time classification according EN
inverter, subject to fan selection.
12101-3 class H250 or H300/ 2hours.
Available specific for your project requirements such
Impeller Data as:

High efficiency aluminum aerofoil type. All units are Ÿ 220-240V / 380-415V-50Hz.

fitted with Breezax Impellers with Aluminum (ALU) Ÿ 60Hz: specific to your voltage requirements.
blades. GRP or GRN blades can be fitted if required. Ÿ 2-speed (Full/Half and Full/Two Thirds).
Hubs are manufactured from fully die cast aluminum Ÿ High temperature motor and double speeds motor
o o
alloy as standard. (Class H): 250 C/2hrs or 300 C/2hrs or requested.
The blades are with adjustable pitch angle to Ÿ Comply with ATEX or IECEx certified motor.
optimize the dutypoint. The solidity varies for a wider Enclosure IP55 or IP66, class F insulation. Fitted
range of performance. with sealed for life ball bearings.

www.breeze.com.vn | breezefans@breeze.com.vn 22
Rooftop Axial Fan
RSC Series
We bring better air to life

Performance Data Sound levels


Full details are available on our selection program: All measurements of the sound that the fans
Breeze Fan or London Fan. generate have been taken strictly in accordance with
Ÿ Manufuactured under a certified ISO 9001:2015. BS 848-2, test method 1 and ISO 13347-2 for
Ÿ The performance is tested international standards
acoustic performance.
by BS 848-1:1985 and ISO 5801. Sound data are determined according to BS EN ISO
Please contact our sale department or login 5136 – In-duct method.
http://www.breeze.com.vn for selection program.

Dimension Information D

Hmax
B
G
E

F A
LxL
All dimensions in mm.

Model A B C D E F G LxL Hmax

RSC 315 315 200 240 750 35 8 50 500x500 550


RSC 355 355 200 240 750 35 8 50 550x550 550
RSC 400 400 200 300 850 40 8 50 600x600 650
RSC 450 450 200 300 850 40 8 50 660x660 720
RSC 500 500 236 300 850 40 12 50 730x730 760
RSC 560 560 236 400 950 50 12 60 810x810 760
RSC 630 630 236 400 1000 50 12 60 900x900 810
RSC 710 710 300 400 1200 50 12 60 990x990 1000
RSC 800 800 315 450 1400 60 12 70 1100x1100 1100
RSC 900 900 355 450 1600 60 14 70 1200x1200 1200
RSC 1000 1000 400 645 1600 60 14 70 1300x1300 1300
RSC 1120 1120 600 645 1800 75 14 70 1500x1500 1500
RSC 1250 1250 600 850 2000 75 14 75 1710x1710 1600
RSC 1400 1400 600 850 2400 75 14 75 1900x1900 1750
RSC 1600 1600 650 1000 3000 100 20 80 2160x2160 1850

Dimensions shown are approximate only. The details please contact local sales office for more information.

www.breeze.com.vn | breezefans@breeze.com.vn 23
Plate Mounted Axial Fan
PA Series
We bring better air to life

Fan Code
o
PA 500 4 10B 20

Pitch Angle
Number of Blades
and Blade Type

Motor Poles

Diameter of Impeller

Fan Type

Casing Motor Data


Fan sizes are from 315mm to 1000mm diameter with Motors incorporated are TEFC (Total Enclosed Fan
air inlet bellmouth. Cooled) and airstream rated to IEC 34-1.
Fan type: Standard motors are protected to IP55 with Class F
Ÿ PA series: Plate Mounted Axial Fan insulation, fitted with sealed for life ball bearings.
Ÿ PAF series: Explosion Proof Plate Mounted Axial
Operating temperature is from -20oC to +50oC as
Fan standard.

Ÿ FLP series: Explosion Proof Propeller Fan


Available specific for your project requirements such
as:
The plates are made of mild steel with epoxy coated
Ÿ 220-240V / 380-415V-50Hz.
after manufacturing, thickness from 2.0mm to 4.0mm
upon diameter. Ÿ High temperature motor and double speeds motor

Airflow direction: (Class H): 250oC/2hrs or 300oC/2hrs or requested

Ÿ Plan B: standard.
Hazardous Area:

Ÿ Plan A can be supplied if required.


Comply with ATEX Directive 2014/34/EU, EN 60079-
0, EN 60079-1 and EN 61241-0.
Impeller Data
High efficiency aluminum aerofoil type. All units are Performance Data
fitted with Breezax Impellers with Aluminum (ALU) Full details are available on our selection program:
blades. GRP or GRN blades can be fitted if required. Breeze Fan or London Fan.
Hubs are manufactured from fully die cast aluminum Ÿ Manufuactured under a certified ISO 9001:2015.
alloy as standard. Ÿ The performance is tested international standards
The impeller of PAF and FLP series are fitted with by BS 848-1:1985 and ISO 5801.
Anti-Static Nylon (AST) or upon requested. Please contact our sale department or login
The blades are with adjustable pitch angle to http://www.breeze.com.vn for selection program.
optimize the dutypoint. The solidity varies for a wider
Sound levels
range of performance.
All measurements of the sound that the fans
Balance: generate have been taken strictly in accordance with
The impellers are statically and dynamically BS 848-2, test method 1 and ISO 13347-2 for
balanced on precision machines according to ISO acoustic performance.
1940 with G2.5mm/s quality standard.

www.breeze.com.vn | breezefans@breeze.com.vn 24
Plate Mounted Axial Fan
PA Series
We bring better air to life

Dimension Information
A
B

Plan B

D
Airflow
C

E
F

Motor Weight
Model A B C D E F
Frame (kg)

PA 315 D71-90 430 304 392 315 80 245 30

PA 355 D71-90 485 355 453 355 85 260 35

PA 400 D71-100 540 496 496 400 100 320 45

PA 450 D71-112 575 385 531 450 100 340 60

PA 500 D71-112 655 465 611 500 120 350 75

PA 560 D71-112 725 535 681 560 120 370 90

PA 630 D71-112 805 615 761 630 150 390 100

D100-112 850 670 810 710 170 410 125


PA 710
D132 145

D100-112 970 736 910 800 200 510 140


PA 800
D132 160

D100-112 1070 838 1006 900 220 570 150


PA 900
D132-160 170-210

D132 1170 936 1106 1000 220 620 200


PA 1000
D160-180 240-300

All dimensions in mm.

* Dimensions shown are approximate only. The details please contact local sales office for more information.

www.breeze.com.vn | breezefans@breeze.com.vn 25
Centrifugal Fan
FCS | BCS Series
We bring better air to life

Fan Code

BCS 280 R

Construction Type:
Ÿ R: Basic Model
Ÿ E: Heavy Duty Model
Ÿ C: Overhang Model

Diameter of Impeller
Fan Type

General Information
The FCS/FCD and BCS/BCD series of centrifugal Fan size:
fans with forward/ backward impellers were Ÿ FCS series: 280mm - 1000mm
developed with advanced technologies. They are Ÿ FCD series: 200mm - 1000mm
designed to bear the BS and ISO standard for air
Ÿ BCS series: 280mm - 1400mm
performance, sound, and efficiency which are
Ÿ BCD series: 250mm - 1250mm
equivalent to AMCA and DIN standard.
These fans can cover the following performance
The centrifugal fan include 15 models as described in
range:
this catalogue. Some of the features and
characteristics of these fans are: forward impeller FCS/FCD series: Air volume rate from 700m3/h -
90.000m3/h, static pressure up 1.500Pa.
blades, a wide range of applications, compact
design, high efficiency, economic exercise, high BCS/BCD series: Air volume rate from 1.000m3/h -
quality execution, low noise and quiet running, and 120.000m3/h, static pressure up 3.000Pa.
low power consumption. These fans are ideal for use These fans have been designed for treating clean air
in central air conditioning systems, in purifiers. The within the temperature limits:
o o
efficiency of all the fans is guaranteed through Ÿ R model: -20 C - 85 C.
o o
specific volume figures at maximum pressure Ÿ E model: -20 C - 85 C.
differentials. Excellent performance and minimal o
Ÿ C model: -30 C - 185 C.
o

noise levels are the features of this new fan range.


(For special execution up to 400oC)
They are also suitable for use in a variety of other
Important: when making a choice of a blowers
ventilation.
consider the limit.
Fan type:
Ÿ Air volume
Ÿ FCS series: Forward curve centrifugal fan with
Ÿ Static pressure
single inlet single width.
Ÿ Output speed of the air
Ÿ BCS series: High efficiency, backward curve
Ÿ Impeller diameter
centrifugal fan with single inlet single width.
Ÿ Absorbed power at the fan shalf
Ÿ FCD series: Forward curve centrifugal fan with
double inlet double width. Ÿ Efficiency and noise levels.

Ÿ BCD series: High efficiency, backward curve Construction Information


centrifugal fan with double inlet double width. FCS/FCD and BCS/BCD series are mainly
constructed of casing, impeller, frame, bearing,
shaft, motor and inlet/outlet flange.

www.breeze.com.vn | breezefans@breeze.com.vn 26
Centrifugal Fan
FCS | BCS Series
We bring better air to life

Casing
Size ranges are from 200mm to 1400mm diameter. Ÿ For sizes 1120mm to 1400mm are made of mild
Ÿ Range sizes from 200mm to 1000mm is made of steel with epoxy painting. The inlet cones are also
hot galvanized steel with EN 10142. The side plates manufactured in black steel and epoxy painted.
include inlets cones that are designed with the best They have thickness from 1.2mm to 5.0mm upon
aerodynamics for inlet condition. The scroll is fixed diameter.
to the side plates by spot welding of “Pittsburgh Stainless steel of casing is provided on request.
seam locking.”

Fan Type Fan Size Fan Diagram Description Bearing Type

FCS 280-710 Forward curve and


FCD 200-710 backward curve with belt
R Model driven.
BCS 280-710
Standard inlet, outlet
BCD 200-710
flanges.
Welded rectangular frame.
FCS 280-1000 Ball bearings on both sides
FCD 200-1000 on separate frame - fan and
E Model
BCS 280-1400 motor on common
BCD 200-1250 baseframe.

Forward curve and


backward curve with
FCS 280-1000
C Model impeller overhang on
BCS 280-1400
the fan shaft, standard
inlet and outlet flanges.

Impeller Data
The impellers are constructed of high grade cold-roll The impellers are secured to the shaft through a
steel, according to the three dimensional flow theory, steel hub.
the impellers are fixed on the center plate and on the Hub bore is precision machined and incorporates as
end ring with welding by high precision laser cutting keyway and locking screw.
machine.
Shaft
All the impellers are designed highest peripheral
speed and high efficiency. The shafts are made of 45 Cr carbon steel bars.
The forward curve impeller of FCS/FCD is made of They are coated after assembly to provide corrosion
hot galvanized steel. resistance. Shaft size should be designed to meet
the first critical speed of at least fan maximum
The backward curve impeller of BCS/BCD is made
running speed 1.4 times.
of mild steel, they are welded and epoxy painting.
Stainless steel of impeller can be provided on Shaft are provided with keyways for the impeller hub
request. and for belt pulleys that can be fitted on either shaft
ends.
All the impellers are statically and dynamically
balanced to ISO 1940 with G2.5mm/s quality Stainless steel of shaft can be provided on request.
standard.

www.breeze.com.vn | breezefans@breeze.com.vn 27
Centrifugal Fan
FCS | BCS Series
We bring better air to life

Frame
The construction frame of R model is made of The one piece bearing housing conforms to ISO
galvanized steel angle iron bars. The cutting and 3228 and allows full utilization of the carrying
bending of the frame parts, as well as the TOX capacity of the mounted regulating bearing. All
connections, are formed with the use of tools to casing are equipped with lubricating bore holes for
ensure the high accuracy and the rigidity of the the possibility of secondary lubrication. As protection
frame. the lubricating bore holes are closed with a synthetic
The heavy duty frames of E and C models are made stopper.
with hot rolled steel and welded by angle steel and The bearing is attached to the shaft by means of an
flat steel with epoxy painting in order to ensure eccentric tension ring. In order to guarantee the
sufficient rigidity and strength. bearing fit is free from play and to avoid corrosion of
All frames can be protected with hot dip galvanized the tension ring sealed with a liquid synthetic.
or stainless steel as an option. Motor Data
Bearing Motors incorporated are TEFC (Total Enclosed Fan
Ball bearings are used in all of all the centrifugal fans. Cooled), and airstream rated to IEC 34-1.
These are high quality bearings and selected to Protected to IP55 with Class F insulation standard.
minimize the fan noise levels. The bearings are pre- Motors are suitable for speed control by frequency
lubricated, sealed and self centering. inverter, subject to fan selection.
For construction of R model, the bearings are Available specific for your project requirements such
supplied with lubricated fittings. R model is used as:
single row, deep groove, self-aligning ball bearings.
Ÿ 220-240V / 380-415V-50Hz
Sealed and lubricated for life, they are locked on the
Ÿ IE1, IE2, IE3 and IE4 Efficiency Classes.
shaft with an eccentric ring clamp and supported,
inside electrically conductive rubber shock Ÿ 2-speed (Full/Half and Full/Two Thirds)

absorbers, on spider shaped holders bolted on the Ÿ High temperature motor and double speeds motor
inlet to the closed side plate. (Class H): 250oC/2hrs or 300oC/2hrs.
For construction of E and C models, the bearings are Ÿ Explosion proof motor: Class F and IP55 or IP66
supplied with redial bearing. E and C models are with completed ATEX 2014/34/EU and EN 50014,
used sealed, single row, self-aligning ball bearings, EN 50018 and EN50281-1-1.
with eccentric clamp, mounted inside cast iron pillow Motor Power:
blocks, with grease nipples, bolted to the side- The power (Pw) on the performance chart refers to
frames or pedestal. the shaft power of the fan.
The bearing service life (L10) are over 100,000 The rated power of the drive motor equals the total
hours (L10 >= 100,000 hours). Limiting values for required shaft input multiplied by the safety factor:
speed and power are indicated in the characteristic
Ps = Pw : m
curve and should not be exceeded. Long term
Where: Ps = total required shaft input power
quality is safeguarded when general assembly and
service guidelines for V-belt drives. m = mechanical efficiency

The grooved ball bearings in the rushed cast iron The mechanical efficiency is provided as follow:
casing are completely sealed and maintenance free. Way of ventilator driving m

Unavoidable alignment errors are compensated by Electric motor directly driven 1


the spherical outer ring. Coupling directly driven 0.98
V-belt driven 0.95

www.breeze.com.vn | breezefans@breeze.com.vn 28
Centrifugal Fan
FCS | BCS Series
We bring better air to life

Outlet/Inlet flange Perfomance Data


The inlet flange is made of high grade cold rolling Full details are available on our selection program:
sheet with epoxy coating. The outlet flange is made Breeze Fan.
of galvanized steel. The connections of the flange Ÿ Manufuactured under a certified ISO 9001:2015.
components to the scroll are made using a TOX non- Ÿ The performance is tested international standards
welding process. This maintains a good flange by BS 848-1:1985 and ISO 5801.
appearance while also providing sufficient strength
Ÿ Installation position B, i.e. free inlet and ducted
and rigidity.
outlet configuration.
Ÿ All curves to a density of = 1,2 kg/m3, at 20oC.
Please contact our sale department or login
http://www.breeze.com.vn for selection program.
The performance curves are provided in this catalogue were measured according to BS 848-1:1985 and
ISO 5801 in the test chamber.
Temperature probe
Flow straightener
Normalize
Test Fan Damper inlet

Differential pressure gauge


Test chamber
BS 848 part 1 / ISO 5801
Sound Level
All measurements of the sound that the fans The sound power levels shown on the fan curves are
generate have been taken strictly in accordance with for inlet LwiA scale for installation type D: ducted
BS 848-2, test method 1 and ISO 13347-2 for inlet, ducted outlet. Ratings include the effects of
acoustic performance. ducted end correction.
Sound data are determined according to BS EN ISO The sound pressure level at the inlet at 1m distance
5136 – In-duct method. in low reflection can be obtained by deducting 11dB
Published sound power level spectra figures are from the sound power level at the inlet side. The
-12
dBW with a reference of 10 Watt (1 Pico watt). sound pressure difference from 1m to distance d is
obtained as follows:
LpiA = 10 * log (1/d)
Where: d = distance from fan in meters.
Sound measurement test rig scheme according to BS 848 part 2:1985 and ISO 5136 in the test duct.

Temperature Microphone with


probe turbulence screen Adjustable
Test Fan
anechoic end

Differential
Test Duct pressure gauge Anechoic
termination
BS 848 part 2 / ISO 5136

www.breeze.com.vn | breezefans@breeze.com.vn 29
Centrifugal Fan
FCS | BCS Series
We bring better air to life

Installation and Maintenance


V-belt Drive Installation Belt Tension
1. Remove the protective coating from the ends of Before tensioning the belts installed on the pulleys,
the fan shaft and ensure that the shaft ends are free mark two thin transverse lines on the back of a belt in
of nick and burrs. the middle of the group of belts, these marks shall be
2. Check fan and motor shafts for alignment. as far apart as possible while remaining together on
3. The center distance must be controlled as 0.7 (d1 the straight part of the belt strand.
+ d2) < a < 2 (d1 + d2). The belt speed of forward Tighten the belts progressively after turning them for
curve fan should be more than 10m/s, but less than about one minute, several times, after each
15m/s, (10 < v < 15m/s). The belt speed of backward adjustment, tighten the pulleys so that the length
curve fan should be more than 25m/s, but less than between the two marks is increased by the
35m/s (25 < v < 35m/s). percentage given in the following table.
4. Slide sheaves on to the shafts, do not hammer the This simplified belt tensioning method will facilitate
sheaves on to the shafts with force as this may result the work done by fitters for maintenance of
in bearing damage. trapezoidal belt transmissions when important
5. Align fan and motor sheaves with a straight edge, technical data are not available. This avoids the
and tighten the sheaves. need to calculate the optimum tension.

6. Place belts over the sheaves with care. Do not Belt tension indicator applied to mid center distance.
bend or squeeze the belts or it might get damaged. Cent
er Di
stan ce
mm d
7. Adjust the belt tension until the belts appear snug. e
1 me flection pe
ter of r
span
Run the unit for a few minutes and allow the belts to
set properly.
8. Switch off the fan, adjust the belt tension by Belt Leng
th
moving the motor base. When in operation, the tight
side of the belts should be in a straight line from
Force require to deflect
sheave to sheave and there should be a slight bow
A belt 16mm per meter of span
on the slack side. Belt
Section Small Pulley/ Newtonian Kilogram
Aligning sheaves with Diameter (mm) (N) force (Kgf)
a straight edge
56-95 13-20 1.3-2.0
Correct SPZ
100-140 20-25 2.0-2.5

80-132 25-35 2.5-3.6


SPA
140-200 35-45 3.6-4.6

Proper 112-224 45-65 4.6-6.6


SPB
236-315 65-85 6.6-8.7
Wrong Wrong Wrong 224-335 85-150 8.7-11.7
SPC
375-560 115-150 11.7-15.3

A 80-140 10-15 1.1-1.5

B 125-200 20-30 2.0-3.1


Offset Pigeon-Toed Angle

www.breeze.com.vn | breezefans@breeze.com.vn 30
Centrifugal Fan
FCS | BCS Series
We bring better air to life

Bearing Installation

1. Before installing, read bearing manufacturers’ 6. Set bearings on support with the scribed marks
procedures. Before putting the new bearings on the locating the bearings. Make sure bearings are
shaft, you may need to break what is called swivel square and level with the shaft.
torque on the bearings (depending on type of 7. Tighten bolts and torque bearing bolts, bearing
bearing). This is done by holding the bearing housing set screws/locking collars as per bearing
securely and being able to move the inner bearing manufacturers’ procedures.
race around freely. 8. Rotate shaft by hand to help allow the bearings to
2. Apply light film of oil on shaft, then gently slide the help set in. Also at this time, listen for any unusual
new bearing onto the shaft. noises such as wheel rubbing on cone and any
bearing noise.
Do not hammer bearing onto the shaft!
9. Connect extended lube lines in new bearings if
3. Align bearings on shaft with the previous scribe
needed.
marks that are on the shaft and lock bearing to shaft.
10. Reinstall the drive sheaves and belts. Check the
4. Put bolts into mounting surface and bearings. Do
belt alignment.
not tighten.
11. Make sure to reinstall all guards and follow
5. Remove block if shaft is supported.
proper safety measures before starting up the fan.

Fan Rotation
Standard fans are supplied with both shaft ends Other accessories may be installed in coded
prepared to fit a pulley. They can be indifferently used standard positions, identified by letters or numbers.
with either RD or LG rotation. All the versions with Please, check the details concerning each particular
side frames can be easily turned to install them in one accessory. When requested, fan orientation is
of the four orientation 0o, 90o and 180o. There is no identified, according to ISO 13349.
need to specify fan orientation when ordering When looking at the fan from the drive side, RD
standard fans. Fan orientation must be specified means right (clockwise) rotation, while LG means
instead when ordering fans fitted with accessories left (counterclockwise) rotation.
which must be located according to the scroll The achievable orientation are shown in the drawing
orientation, like drain plugs. below.

Rotation 0o 90o 180o

RD
Right Hand
(Clockwise)

LG
Left Hand
(Counterclockwise)

www.breeze.com.vn | breezefans@breeze.com.vn 31
Centrifugal Fan
FCS | BCS Series
We bring better air to life

Dimension Information
FCS/BCS-R: Basic Model

o o
Rotation Flanges 90 180

60

L
RD L

C
Inlet Flange

C
A
Right Hand
A B
B A

LG L
L
Outlet Flange B D

C
Left Hand
B A
A B

Size Frame A B C D E Amax B C Amax B C

280 71-112 292 361 197 417 253 1130 400 516 1050 400 568

315 71-112 322 404 223 460 279 1200 435 568 1100 435 628

355 71-112 362 453 238 509 294 1280 465 628 1160 465 705

71-112 404 507 258 563 314 1360 495 701 1230 495 786
400
132 404 507 258 563 314 1380 495 701 1250 495 786

80-112 448 569 288 625 344 1420 550 776 1300 550 877
450
132 448 569 288 625 344 1470 550 776 1380 550 877

80-112 510 638 324 684 380 1530 590 850 1380 590 968
500
132 510 638 324 684 380 1550 590 850 1400 590 968

90-112 570 715 368 771 424 1620 635 956 1460 635 1093
560
132-160 570 715 368 771 424 1740 635 956 1560 635 1093

90-112 635 801 412 857 468 1780 685 1062 1560 685 1220
630
132-160 635 801 412 857 468 1880 685 1062 1650 685 1220

90-112 722 898 468 954 524 1920 740 1184 1680 740 1366
710
132-160 722 898 468 954 524 2000 740 1184 1770 740 1366

All dimensions in mm.

* Dimensions shown are approximate only. The details please contact local sales office for more information.

www.breeze.com.vn | breezefans@breeze.com.vn 32
Centrifugal Fan
FCS | BCS Series
We bring better air to life

Dimension Information
FCS/BCS-E: Heavy Duty Model

o o
Rotation Flanges 90 180

60

L
RD L

C
Inlet Flange

C
A
Right Hand
A B
B A

LG L
L
Outlet Flange B D

C
Left Hand
B A
A B

Size Frame A B C D E Amax B C Amax B C

280 80-112 292 361 197 417 253 1130 430 516 1050 430 568

315 80-112 322 404 223 460 279 1200 465 568 1100 465 628

355 80-112 362 453 238 509 294 1280 495 628 1160 495 705

90-112 404 507 258 563 314 1360 525 701 1230 525 786
400
132 404 507 258 563 314 1380 525 701 1250 525 786

90-112 448 569 288 625 344 1420 580 776 1300 580 877
450
132 448 569 288 625 344 1470 580 776 1320 580 877

90-112 510 638 324 684 380 1530 620 850 1380 620 968
500
132-160 510 638 324 684 380 1640 620 850 1480 620 968

100-112 570 715 368 771 424 1620 665 956 1460 665 1093
560
132-160 570 715 368 771 424 1740 665 956 1560 665 1093

100-112 635 801 412 857 468 1780 715 1062 1560 715 1220
630
132-160 635 801 412 857 468 1880 715 1062 1650 715 1220

100-132 722 898 468 954 524 1940 770 1184 700 770 1366
710
160-200 722 898 468 954 524 2100 770 1184 1870 770 1366

800 112-160 808 1007 520 1063 576 2150 825 1330 1850 825 1548

www.breeze.com.vn | breezefans@breeze.com.vn 33
Centrifugal Fan
FCS | BCS Series
We bring better air to life

Dimension Information
FCS/BCS-E: Heavy Duty Model

Rotation Flanges 90o 180o

60

L
RD L

C
Inlet Flange

C
A
Right Hand
A B
B A

LG L
L
Outlet Flange B D

C
Left Hand
B A
A B

Size Frame A B C D E Amax B C Amax B C

800 180-225 808 1007 520 1063 576 2320 825 1330 2020 825 1548

112-132 896 1130 580 1186 638 2280 905 1488 1950 905 1728

900 160-180 896 1130 580 1186 638 2420 905 1488 2080 905 1728

200-225 896 1130 580 1186 638 2520 905 1488 2180 905 1728

132-180 996 1267 663 1323 719 2580 975 1621 2230 975 1890
1000
200-250 996 1267 663 1323 719 2750 975 1621 2400 975 1890

160-180 1018 1468 725 1526 825 2810 1200 1900 2410 1200 2050

1120 200-225 1018 1468 725 1526 825 2960 1200 1900 2560 1200 2050

250-280 1018 1468 725 1526 825 3050 1200 1900 2650 1200 2050

160-180 1310 1588 800 1688 900 3060 1300 2100 2610 1300 2400

1250 200-225 1310 1588 800 1688 900 3210 1300 2100 2760 1300 2400

250-280 1310 1588 800 1688 900 3300 1300 2100 2850 1300 2400

160-180 1450 1776 902 1876 1002 3310 1450 2300 2810 1450 2700

1400 200-225 1450 1776 902 1876 1002 3460 1450 2300 2960 1450 2700

250-280 1450 1776 902 1876 1002 3550 1450 2300 3050 1450 2700

All dimensions in mm.

* Dimensions shown are approximate only. The details please contact local sales office for more information.

www.breeze.com.vn | breezefans@breeze.com.vn 34
Centrifugal Fan
FCS | BCS Series
We bring better air to life

Dimension Information
FCS/BCS-C: Overhang Model

o o
Rotation Flanges 90 180

60

RD L L
Inlet Flange

C
C
A
Right Hand

B A A B

LG L
Outlet Flange B D L

C
C

Left Hand

A B B A
E

Size Frame A B C D E Amax B C Amax B C

280 80-112 292 361 197 417 253 1130 675 516 1050 675 568

315 80-112 322 404 223 460 279 1200 700 568 1100 700 628

355 80-112 362 453 238 509 294 1280 775 628 1160 775 705

90-112 404 507 258 563 314 1360 800 701 1230 800 786
400
132 404 507 258 563 314 1380 800 701 1250 800 786

90-112 448 569 288 625 344 1420 894 776 1300 894 877
450
132 448 569 288 625 344 1470 894 776 1320 894 877

90-112 510 638 324 684 380 1530 930 850 1380 930 968
500
132-160 510 638 324 684 380 1640 930 850 1480 930 968

100-112 570 715 368 771 424 1620 1020 956 1460 1020 1093
560
132-160 570 715 368 771 424 1740 1020 956 1560 1020 1093

100-112 635 801 412 857 468 1780 1065 1062 1560 1065 1220
630
132-160 635 801 412 857 468 1880 1065 1062 1650 1065 1220

100-132 722 898 468 954 524 1940 1185 1184 1700 1185 1366
710
160-200 722 898 468 954 524 2100 1185 1184 1870 1185 1366

800 112-160 808 1007 520 1063 576 2150 1245 1330 1850 1245 1548

www.breeze.com.vn | breezefans@breeze.com.vn 35
Centrifugal Fan
FCS | BCS Series
We bring better air to life

Dimension Information
FCS/BCS-C: Overhang Model

o o
Rotation Flanges 90 180

60

RD L L
Inlet Flange

C
C
A
Right Hand

B A A B

LG L
Outlet Flange B D L

C
C

Left Hand

A B B A
E

Size Frame A B C D E Amax B C Amax B C

180-225 808 1007 520 1063 576 2320 1245 1330 2020 1245 1548

112-132 896 1130 580 1186 638 2280 1375 1488 1950 1375 1728

900 160-180 896 1130 580 1186 638 2420 1375 1488 2080 1375 1728

200-225 896 1130 580 1186 638 2520 1375 1488 2180 1375 1728

132-180 996 1267 663 1323 719 2580 1450 1621 2230 1450 1890
1000
200-250 996 1267 663 1323 719 2750 1450 1621 2400 1450 1890

160-180 1018 1468 725 1526 825 2810 1600 1900 2410 1600 2050

1120 200-225 1018 1468 725 1526 825 2960 1600 1900 2560 1600 2050

250-280 1018 1468 725 1526 825 3050 1600 1900 2650 1600 2050

160-180 1310 1588 800 1688 900 3060 1750 2100 2610 1750 2400

1250 200-225 1310 1588 800 1688 900 3210 1750 2100 2760 1750 2400

250-280 1310 1588 800 1688 900 3300 1750 2100 2850 1750 2400

160-180 1450 1776 902 1876 1002 3310 1950 2300 2810 1950 2700

1400 200-225 1450 1776 902 1876 1002 3460 1950 2300 2960 1950 2700

250-280 1450 1776 902 1876 1002 3550 1950 2300 3050 1950 2700

All dimensions in mm.

* Dimensions shown are approximate only. The details please contact local sales office for more information.

www.breeze.com.vn | breezefans@breeze.com.vn 36
Centrifugal Fan
FCS | BCS Series
We bring better air to life

Installation Guide
Flexible Connection

Belt Guard Outlet Duct

Airflow

Adjust Bolt Spring Isolator


to reach Building Construction

Fig 01. Mounting type

Building Construction Building Contruction

Adjust Bolt Spring Isolator


to reach Spring Isolator
Flexible Connection

Stud

Belt Guard Outlet Duct

Airflow

U-steel
support

Fig 02. Hanging type

Building Construction

Inlet Duct
In case: Installation position B,
i.e. free inlet and ducted outlet
configuration. L = Diameter
Flexible Connection
Obstruction at fan inlet:
Allow a gap of at least one fan
diameter between fan inlet and Outlet Duct
Airflow
obstruction and fit a diffuser on
the discharge.

Fig 03. Top view

www.breeze.com.vn | breezefans@breeze.com.vn 37
Plug Fan
PF Series
We bring better air to life

Fan Code
PF 500 R

Construction Type:
Ÿ R: Basic Model
Ÿ E: Heavy Duty Model

Diameter of Impeller

Plug Fan

General Information Motor Data


Plug fan is a complete fan assembly to be used in Air Motors incorporated are TEFC (Total Enclosed Fan
Handling units. The fan is available in 13 sizes and Cooled) and airstream rated to IEC 34-1.
covers airflow up to 70.000 m3/h and pressure rises Protected to IP55 with Class F insulation standard.
up to 3.000 Pa. Motors are suitable for speed control by frequency
The fan is installed on the floor inside the AHU using inverter, subject to fan selection.
anti vibration mountings. Available specific for your project requirements such
The impeller is designed backward curve to work as:
inside the Air Handling Unit to give best performance Ÿ 220-240V / 380-415V-50Hz
for:
Ÿ IE1, IE2, IE3 and IE4 Efficiency Classes.
Ÿ High overall efficiency.
Ÿ High temperature motor and double speeds motor
Ÿ Low sound levels at inlet and outlet
(Class H): 250oC/2hrs or 300oC/2hrs.
Ÿ Easy installation
Inlet Cone
Ÿ Lowest possible vibration levels.
The design of the fan inlet is designed to optimize the
Construction Information flow into the impeller. The inlet is in one piece and
PF series are mainly constructed of base frame, made of hot galvanized steel or stainless steel upon
backward curve impeller, motor and front plate, inlet requested.
cone and wrap part. Performance Data
Mounting Bracket Full details are available on our selection program:
Base frame, motor bracket and front plate are made Breeze Fan.
of mild steel with powder coated finishing. Ÿ Manufuactured under a certified ISO 9001:2015.
Base frame is fitted together with impeller, inlet cone Ÿ The performance is tested international standards
and motor. by BS 848-1:1985 and ISO 5801.
Impeller Ÿ All curves to a density of = 1,2 kg/m3, at 20oC.
The plug fan impeller is made of powder coated steel Sound Level
with backward curve blades. The impeller is All measurements of the sound that the fans
aerodynamically designed for high efficiency and generate have been taken strictly in accordance with
low power consumption. They are balanced BS 848-2, test method 1 and ISO 13347-2 for
according to ISO 1940:G2.5mm/s quality standard. acoustic performance.
The impeller has a GG-hub with taper lock bush.

www.breeze.com.vn | breezefans@breeze.com.vn 38
Plug Fan
PF Series
We bring better air to life

Dimension Information

Model A B C Od

PF 250 376 226 475 14

PF 280 400 238 475 14

PF 315 430 253 520 14

PF 355 462 269 533 14


Od PF 400 502 289 586 14
C
PF 500 612 348 760 14

PF 560 688 400 870 18

PF 630 769 440 920 18

PF 710 850 510 1000 18

PF 800 940 550 1100 20

PF 900 1044 632 1200 20


B

PF 1000 1140 680 1320 20

All dimensions in mm.


A

Fan Size D E F K L nmax

L 250 257 80 118 259 158 4500

F 280 289 89 133 286 180 4300

E 315 324 100 146 320 201 4000

355 365 112 162 356 224 3500

400 410 126 185 395 253 2900

450 460 142 210 438 282 2900

500 517 159 235 487 317 2500


D
K

560 578 178 262 541 357 2200

630 648 199 293 605 402 1900

710 728 224 328 674 450 1600

800 818 252 368 751 507 1400

900 917 282 413 837 564 1250

1000 1012 316 462 934 629 960

All dimensions in mm.

Dimensions shown are approximate only. The details please contact to local sales office for more information.

www.breeze.com.vn | breezefans@breeze.com.vn 39
Cabinet Centrifugal Fan
KB Series
We bring better air to life

Fan Code
KBF 280 R

Construction Type:
Ÿ R: Basic Model
Ÿ E: Heavy Duty Model
Ÿ F: Smoke Spill Model

Diameter of Impeller
Fan Type

General Information Frame Structure


Size range from 200mm to 1250mm diameter. Channel steel base, not easy to be deformed.
KBF/KBB/KBP series are designed and developed Aluminum frame, easy to be installed, strong
on the basis of advanced technology from United structure and low weight high quality painted steel
Kingdom. It has the features of high efficiency, low plate and cold rolled steel painted with static
noise, excellent performance, compact structure, electronic process can prolong fan life. Fine seam
easy installation and so on. disposition. Low air leakage. The box board is made
KBF-F/KBB-F series are dual purpose fans of foaming technology and sound insulation cotton.
(standard and smoke spill) they can continuous Scientific cabinet design
operate over 0.5 hours when the flue gas Save every possible space. Confirm strict tolerance
o
temperature reaches 280 C, these fans have been of the parts to meet the precision.
tested by the “National Fire Equipment Quality Save every possible space to broaden inlet size
Supervision and Test Center”. They are new types for which introduces the airstream smoothly.
high rise buildings for the dual purpose ventilation. Motor position and belt length have been arranged
Fan type: without any redundancy.
Ÿ KBF series: Forward curve double inlet cabinet High quality parts with high reliability.
centrifugal fan. Human oriented design concept benefits the
Ÿ KBB series: High efficiency, backward curve double maintenance work.
inlet cabinet centrifugal fan. Access door designed in both sides and can be
Ÿ KBP series: High efficiency, backward curve single opened tool free.
inlet cabinet plug fan. Impeller Data
Fan size: All the impellers are designed highest peripheral
Ÿ KBF Series: 200mm to 1000mm speed and high efficiency.
Ÿ KBB Series: 250mm to 1250mm The forward curve impeller of KBF is made of hot
Ÿ KBP Series: 250mm to 1000mm galvanized steel.
The backward curve impeller of KBB/KBP is made of
Construction Information
mild steel, they are welded and epoxy painting.
KBF/KBB/KBP series are mainly constructed of
Stainless steel of impeller can be provided on
aluminum cabinet frame, fan casing, impeller, frame,
request.
bearing, shaft, motor and inlet/outlet flange.
All the impellers are statically and dynamically
balanced to ISO 1940 with G2.5mm/s quality
standard.

www.breeze.com.vn | breezefans@breeze.com.vn 40
Cabinet Centrifugal Fan
KB Series
We bring better air to life

Motor Data
Motors incorporated are TEFC (Total Enclosed Fan Ÿ IE1, IE2, IE3 and IE4 Efficiency Classes.
Cooled) and airstream rated to IEC 34-1. Ÿ 2-speed (Full/Half and Full/Two Thirds)
Protected to IP55 with Class F insulation standard. Ÿ High temperature motor and double speeds motor
Motors are suitable for speed control by frequency (Class H): 250oC/2hrs or 300oC/2hrs.
inverter, subject to fan selection. Ÿ Explosion proof motor: Class F and IP55 or IP66
Available specific for your project requirements such with completed ATEX 2014/34/EU and EN 50014,
as: EN 50018 and EN50281-1-1.
Ÿ 220-240V / 380-415V-50Hz

Dimension Information
KBF/KBB Series: Inside Motor
A
E

G1xG2
G3xG4

Airflow
C

Inlet

D
8-Od 4-O30 L
L1
B
All dimensions in mm.

Model A B C D E G1 G2 G3 G4 L L1 Od

KB 200 960 990 625 50 690 256 256 453 568 600 850 15
KB 225 1000 1020 670 50 720 288 288 498 598 650 880 15
KB 250 1050 1050 710 50 750 322 322 538 628 680 910 15
KB 280 1120 1100 813 63 800 361 361 628 678 720 960 15
KB 315 1250 1270 878 63 970 404 404 673 828 850 1130 15
KB 355 1300 1350 953 63 1050 453 453 748 908 930 1210 15
KB 400 1480 1560 1130 80 1260 507 507 908 1118 1060 1420 15
KB 450 1550 1630 1220 80 1330 569 569 998 1188 1100 1470 15
KB 500 1600 1800 1310 80 1400 638 638 1258 1088 1160 1600 15
KB 560 1750 1850 1460 100 1450 715 715 1308 1218 1300 1650 18
KB 630 1880 2000 1590 100 1600 801 801 1458 1348 1320 1794 18
KB 710 2100 2200 1685 100 1800 898 898 1420 1635 1400 2000 18
KB 800 2280 2400 1855 100 2010 1007 1007 1848 1593 1600 2200 18
KB 900 2500 2600 2180 100 2210 1130 1130 2048 1793 1700 2400 18
KB 1000 2650 2750 2210 100 2360 1267 1267 2198 1948 1900 2550 18

* Dimensions shown are approximate only. The details please contact local sales office for more information.

www.breeze.com.vn | breezefans@breeze.com.vn 41
Cabinet Centrifugal Fan
KB Series
We bring better air to life

Dimension Information
KBF-F/KBB-F Series: External Motor
A
C

G1xG2
G3xG4
D

Inlet Airflow

8-O17 L1 4-O30
L
B

C
Model A B D L L1 G1xG2 G3xG4
Y80 Y90 Y100 Y112 Y132 Y160 Y180 Y200 Y225

KB 200 610 790 860 540 498 690 256 428x328

KB 225 660 850 900 925 580 543 750 288 465x405

KB 250 710 910 940 960 630 593 810 322 525x455

KB 280 780 980 1020 1040 1070 703 663 880 361 595x515

KB 315 670 1060 1080 1100 1130 1160 1200 1295 763 420 960 404 655x555

KB 355 740 1160 1160 1180 1220 1250 1280 1380 1420 843 488 1060 453 755x635

KB 400 810 1260 1280 1300 1330 1380 1470 1520 930 513 1160 507 855x708

KB 450 890 1400 1360 1400 1430 1480 1570 1610 1660 1030 581 1300 569 978x808

KB 500 960 1520 1460 1500 1520 1570 1650 1700 1750 1120 650 1420 639 1095x895

KB 560 1060 1680 1600 1640 1660 1710 1800 1850 1900 1265 745 1580 715 1235x1020

KB 630 1160 1830 1760 1790 1830 1930 1970 2030 1390 846 1730 801 1385x1145

KB 710 1300 2020 1930 1970 2060 2110 2160 2210 1530 902 1920 898 1555x1265

KB 800 1430 2220 2140 2230 2270 2330 2380 1700 1030 2120 1007 1955x1435

KB 900 1610 2450 2290 2380 2425 2480 2535 1850 1166 2350 1130 1985x1585

KB 1000 1740 2700 2450 2540 2590 2640 2690 2010 1302 2600 1267 2235x1745

All dimensions in mm.

* Dimensions shown are approximate only. The details please contact local sales office for more information.

www.breeze.com.vn | breezefans@breeze.com.vn 42
Cabinet Centrifugal Fan
KB Series
We bring better air to life

Dimension Information
KBP Series
E A
F
C
D

G1
Inlet Airflow

8-Od L1 L
B

Model A B C D E F G1 H L L1 Od

KBP 250 582 790 563 500 500 500 380 135 360 660 14
KBP 280 612 820 593 530 530 530 408 135 370 690 14
KBP 315 682 890 663 600 600 600 478 135 440 760 14
KBP 355 702 910 683 630 630 630 790 135 460 780 14
KBP 400 755 970 743 680 680 680 538 138 505 840 14
KBP 450 855 1080 860 780 780 780 638 155 590 940 14
KBP 500 975 1200 980 900 900 900 758 155 710 1060 14
KBP 560 1035 1260 1040 960 960 960 810 160 770 1120 14
KBP 630 1085 1310 1090 1010 1010 1010 868 160 810 1170 14
KBP 710 1205 1430 1230 1130 1130 1130 968 190 850 1290 14
KBP 800 1325 1550 1350 1250 1250 1250 1088 190 930 1410 14
KBP 900 1472 1700 1500 1400 1400 1400 1238 190 1060 1560 18
KBP 1000 1625 1850 1650 1550 1550 1550 1388 190 1150 1710 18

All dimensions in mm.

* Dimensions shown are approximate only. The details please contact local sales office for more information.

www.breeze.com.vn | breezefans@breeze.com.vn 43
Cabinet Centrifugal Fan
KB Series
We bring better air to life

Installation Guide

Flexible Connection

Outlet Duct
Airflow
Inlet Duct

Adjust Bolt Spring Isolator


to reach Building Construction

Fig 01. Mounting type

Building Construction

Spring Isolator

Stud

Steel Support

Fig 02. Hanging type

Building Construction

Spring Isolator
Flexible Connection Stud

Outlet Duct
Inlet Duct Airflow

Steel Support

Fig 03. Hanging type

www.breeze.com.vn | breezefans@breeze.com.vn 44
Inline Centrifugal Fan
CDF/CDFS Series
We bring better air to life

Impeller
Double forward curved impellers are made of hot
galvanized steel. The impeller is constructed with
maximum strength that endures the continuous
operation with maximum power. Balanced by ISO
1940 with G2.5mm/s quality standard.
Motor
The motor is designed for double blower fan with
outer rotor structure. The characteristic is compact
structure, short axial size low noise. It can adjust
speed as well as change voltage. It is ideal motors for
General Information
fan, dust cleaner. Standard motors are protected to
The CDF/CDFS series are built-in double inlet IP55, class F insulation.
forward curve centrifugal fan. Electrical connection
Ÿ CDF series: Standard fan. CDF/CDFS series motor with a cable, and protection
Ÿ CDFS series: Silencer box to meet the to IP55 junction box connection to external,
requirements of low noise. removable terminal block.
The special motors can be configured through the 3-
Performance data
phase voltage regulator, SCR voltage regulator,
inverter and other means of speed, changing to meet Manufuactured under a certified ISO 9001:2015.
system load requirements. The performance is tested international standards by
BS 848-1:1985 and ISO 5801.
Construction Information
Installation position D, i.e. ducted inlet and ducted
CDF/CDFS series consist of box casing, fan casing,
outlet configuration.
impeller, motor, inlet and outlet flanges and electrical
All curves to a density of = 1,2 kg/m3, at 20oC.
connection.
Casing Sound levels
CDF/CDFS series are made of hot galvanized steel
All measurements of the sound that the fans
square pipe type. The pipe and the air inlet side have
generate have been taken strictly in accordance with
a 20mm standard flange. BS 848-2, test method 1 and ISO 13347-2 for
CDFS series’ aluminum tenon joint structure design acoustic performance.
together with three high-quality silencer cotton Sound data are determined according to BS EN ISO
board, effective at 15dB acoustic noise around. 5136 – In-duct method.
Performance Curve
Pa CDF/CDFS 200-4 Pa CDF/CDFS 225-4

300 350

250 300
250
200
200
150
150
100
100
50 50
m3/h m3/h
1000 1200 1400 1600 1800 2000 1600 1800 2000 2200 2400 2600 2800 3000

www.breeze.com.vn | breezefans@breeze.com.vn 45
Inline Centrifugal Fan
CDF/CDFS Series
We bring better air to life

Pa CDF/CDFS 250-4 Pa CDF/CDFS 280-4

450 500

400 450

350 400

300 350

250 300
m3/h m3/h
1900 2100 2300 2500 2700 2900 3100 3300 3500 2000 2400 2800 3200 3600 4000 4400 4800

Pa CDF/CDFS 315-4 Pa CDF/CDFS 355-4

750 900
700
650 800
600
700
550
500
600
450
400 500
m3/h m3/h
4000 4400 4800 5200 5600 6000 3000 4000 5000 6000 7000 8000

Pa CDF/CDFS 355-6 Pa CDF/CDFS 400-6


500
350
325 450

300 400
275
350
250
300
225
200 250
m3/h m3/h
3500 4000 4500 5000 5500 6000 6500 7000 7500 6000 6500 7000 7500 8000 8500 9000 9500 10000

Pa CDF/CDFS 450-6 Pa CDF/CDFS 500-6

650 800
600 750
550 700
500 650
450 600
400 550
350 500
3
m /h m3/h
8000 8500 9000 9500 10000 10500 11000 11000 12000 13000 14000 15000 16000

www.breeze.com.vn | breezefans@breeze.com.vn 46
Inline Centrifugal Fan
CDF/CDFS Series
We bring better air to life

Performance Parameters
Max. Max. Noise
Power Current Speed Voltage
Model Air Volume Pressure dBA
(kW) (A) (rpm/min) (V/P/Hz)
(m3/h) (Pa) (@ 3m)

CDF/CDFS 200-4 2000 250 0.25 0.88 1440 380/3/50 53/46

CDF/CDFS 225-4 3000 350 0.45 1.39 1440 380/3/50 55/48

CDF/CDFS 250-4 3500 450 0.8 2.31 1440 380/3/50 56/49

CDF/CDFS 280-4 4500 500 0.8 2.31 1440 380/3/50 57/50

CDF/CDFS 315-4 6500 750 1.8 4.47 1440 380/3/50 59/52

CDF/CDFS 355-4 8000 850 3.0 6.95 1440 380/3/50 65/58

CDF/CDFS 355-6 7500 350 1.8 4.8 960 380/3/50 60/53

CDF/CDFS 400-6 10000 500 3.0 7.5 960 380/3/50 64/57

CDF/CDFS 450-6 11000 650 4.0 9.9 960 380/3/50 67/60

CDF/CDFS 500-6 16000 800 7.5 17.7 960 380/3/50 69/62

Dimension Information D
A
G1xG2
G3xG4

C
Inlet Airflow

4 - O15

E
B
All dimensions in mm.
Weight
Model A B C D E G1 x G2 G3 x G4 (Kg)

CDF/CDFS 200-4 529 600 460 500 550 223 x 229 318 x 378 22

CDF/CDFS 225-4 569 630 500 530 580 251 x 262 358 x 408 42

CDF/CDFS 250-4 589 650 520 550 600 277 x 285 378 x 428 44

CDF/CDFS 280-4 639 740 570 640 690 309 x 304 428 x 518 50

CDF/CDFS 315-4 749 815 680 715 765 342 x 342 538 x 593 70

CDF/CDFS 355-4/6 789 890 720 790 840 379 x 379 578 x 668 90

CDF/CDFS 400-6 859 960 790 860 910 423 x 423 648 x 738 110

CDF/CDFS 450-6 939 1080 870 980 1030 473 x 473 728 x 858 125

CDF/CDFS 500-6 1019 1200 950 1100 1150 510 x 510 808 x 978 190

www.breeze.com.vn | breezefans@breeze.com.vn 47
Inline Centrifugal Fan
CDF/CDFS Series
We bring better air to life

Wiring Diagram
Ÿ Check that supply is according to data on Ÿ The equipment connected ground for motor
nameplate. protection according to the instructions - Unless the
Ÿ Insert cable according to the instructions in the guarantee isn’t accepted.
junction box and seal it. Ÿ Connect electric supply.

KM1 Fan
L1 Black 1 MCB Fan
AC ~
L1
380-415V L2 Blue 2 Black 1
AC ~
50 Hz L2
L3 Red 3 380-415V Blue 2
4 50 Hz
L3
Red 3
Where: 5
Thermal 6 TW1
White 1 White 1 4
S1
White 2 overload “ON”
White 1 7 TW2
protection S2 White 2 5
“OFF”
White 2 8 PE
N 6
9
PE

Installation Guide
Flexible Connection

Inlet Duct Outlet Duct

Spring Isolator Building Construction

Fig 01. Mounting type


Building Contruction Building Contruction

Adjust nut to reach Spring Isolator Adjust nut to reach Spring Isolator

Stud

Flexible Connection

Inlet Duct Outlet Duct

U-steel support
U-steel support

Fig 02. Hanging type

www.breeze.com.vn | breezefans@breeze.com.vn 48
Silent Inline Fan
DVS Series
We bring better air to life

General Information
DVS series use a silent inline fan with high quality
material and exceptionally super low noise level design.
The idea solution for medium demand ventilation in
commercial and residential systems. Application suitable
for bathroom, bedroom, office, living room, store, toilets,
hotels with low noise requirements and supply or exhaust
ventilation.

Construction Information
The casings are used stainless plate steel with
characteristic of fire prevention and anti-corrosion.
The impeller is made in stainless steel with high energy
Feature efficiency of forward curve centrifugal impeller in favor of
Ÿ Super low noise. drastically reducing noise.
Ÿ Energy saving. The motor is made of 100% copper coil and fitted with
Ÿ Easy installation, service and clean. high quality ball bearing, high efficiency, low noise,
Ÿ Compact design. maintenance free and long service life. Equipped with
Ÿ Be able to speed controllable. thermal overload protection.
Ÿ Strong and durable.
Testing
Ÿ Light weight.
Ÿ Innovative U-shaped link for easy installation in The performance has been tested in accordance with
any position. ISO 5801. The sound data has been determined by
Ÿ Can be installed directly on the wall. testing to ISO 13347-2. The fans have passed QCVN
Ÿ Standard motor range is protected to IP 44, 04:2009/BKHCN and TCVN 5699-2-80:2007 (IEC
class B insulation. 60335) standard for electric safety.

Performance Curve
DVS 180 DVS 300 DVS 500
Pa Pa Pa

125 200 200

100 150 150

75 100 100

50 50 50

3
600 m /h
3 3
40 80 120 160 200 240 m /h 60 120 180 240 300 360 m /h 100 200 300 400 500

DVS 780 DVS 960


Pa Pa
250 250

200 200

150 150

100 100

50 50

3 3
150 300 450 600 750 900 m /h 200 400 600 800 1000 1200 m /h

www.breeze.com.vn | breezefans@breeze.com.vn 49
Silent Inline Fan
DVS Series
We bring better air to life

DVS 1200 DVS 1900 DVS 3000


Pa Pa Pa
500 500 500

400 400 400

300 300 300

200 200 200

100 100 100

3 3 3
200 400 600 800 1000 1200 m /h 400 800 1200 1600 2000 2400 m /h 500 1000 1500 2000 2500 3000 m /h

Performance Parameters

Max. Max. Noise


Power Current Speed Voltage
Model Air Volume Pressure dBA
(W) (A) (rpm/min) (V/P/Hz)
(m3/h) (Pa) (at 3m)

DVS 180 180 125 25 0.11 1180 220/1/50 21

DVS 300 300 150 47 0.23 1140 220/1/50 25

DVS 500 500 200 98 0.45 1360 220/1/50 28

DVS 780 780 230 155 0.72 1180 220/1/50 35

DVS 960 960 250 163 0.75 1280 220/1/50 37

DVS 1200 1200 440 185 0.84 820 220/1/50 40

DVS 1900 1900 460 385 1.75 1060 220/1/50 46

DVS 3000 3000 480 420 1.9 1280 220/1/50 49

Dimension Information
B

Weight
Model A B C D E
(Kg)

DVS 180 184 286 395 288 100 4.4


A

DVS 300 206 288 407 299 150 4.5

DVS 500 206 288 407 299 150 4.5

C DVS 780 270 390 548 420 200 11


D
DVS 960 270 390 548 420 200 11

DVS 1200 330 470 650 490 250 18


E

DVS 1900 330 470 650 490 250 35

DVS 3000 330 470 650 490 250 38

All dimensions in mm.


Airflow

www.breeze.com.vn | breezefans@breeze.com.vn 50
Silent Inline Fan
DVS Series
We bring better air to life

Wiring Diagram
MCB Fan
Terminals L
Black L Brown AC ~ L 1
FU 220-240V
N
Motor Blue N Blue 50 Hz 2
Capacity
N 3
Brown Yellow
Green PE
Yellow Green 4

Installation Method
Ÿ The fan is designed direct connection to air duct.
Ÿ Take care of direction of air flow shown by arrow
stickers.
Ÿ Apply the markings for mounting of the fixing
brackets onto the mounting surface. Airflow
Ÿ Drill the holes and fasten the fan on the brackets by
using appropriate fasteners.
Ÿ Install the fan with bolts and nut to the building
construction (refer to the right picture).

Airflow

Airflow
Airflow

If you need prevent vibration, The product of hanging


Install the boom, flat washers,
please use the shockproof rubber ceiling structure and
nuts (customer need purchase
(customer need purchase by suspension components
by yourself, you must use the
yourself), its strength must be able must be able to carry more
M8-M10 specifications).
to carry this product’s weight. than five times intensity.

Install firmly bolts and nuts Install the bolt


when it hanging down. Casing to be installed
horizontally
Nut Leading to the outdoor air duct
must remain slight slope.
Flat washer
Size A bolt is 2-3 helicoidal Put the bags or canvas
than the Nut connect together

Air
low

www.breeze.com.vn | breezefans@breeze.com.vn 51
Mixed Flow Inline Fan
MFD Series
We bring better air to life

General Information
MFD series use a mixed flow inline fan with two speeds
motor as standard and exceptionally low noise level
design. The idea solution for medium demand ventilation
in commercial and residential systems. Application
suitable for bathroom, bedroom, office, living room,
store, toilets, hotels, etc. Suitable for room to room air
transfer and supply or exhaust ventilation.

Construction Information
The casings are made from injection moulded ABS
polymer.
The range is fitted with mixed flow impeller driven by long
Feature
life motor sealed for life bearing.
Ÿ High or low speed operation.
The motor is made of 100% copper coil and fitted with
Ÿ High efficiency.
high quality ball bearing, high efficiency, low noise,
Ÿ Low noise.
maintenance free and long service life. Equipped with
Ÿ Easy installation, service and clean.
thermal overload protection.
Ÿ Compact design.
Ÿ Speed controllable with VA controller. Testing
Ÿ Fitted with terminal box on the casing. The performance has been tested in accordance with
Ÿ Strong and durable. ISO 5801. The sound data has been determined by
Ÿ Light weight. testing to ISO 13347-2. The fans have passed QCVN
Ÿ Can be installed directly on the wall. 04:2009/BKHCN and TCVN 5699-2-80:2007 (IEC
Ÿ Standard motor range is protected to IP 44, 60335) standard for electric safety.
class B insulation.

Performance Curve H: L:
MFD 100 MFD 150 MFD 200
Pa Pa Pa
400
160 320
300
120 240

200
80 160

100
40 80

3 3
50 100 150 200 250 m /h 100 200 300 400 500 600 m /h 200 400 600 800 1000 1200 m /h

MFD 250
Pa
600
500
400
300
200
100

3
300 600 900 1200 1500 m /h

www.breeze.com.vn | breezefans@breeze.com.vn 52
Mixed Flow Inline Fan
MFD Series
We bring better air to life

Performance Parameters

Max. Max. Noise


Power Current Speed Voltage
Model Air Volume Pressure dBA
(W) (A) (rpm/min) (V/P/Hz)
(m3/h) (Pa) (at 3m)
H: 220 180 28 0.12 2500 48
MFD 100 220/1/50
L: 185 150 25 0.11 2127 40
H: 550 300 50 0.21 2500 52
MFD 150 220/1/50
L: 410 240 40 0.18 2000 44
H: 900 350 70 0.30 2500 57
MFD 200 220/1/50
L: 700 250 60 0.25 2100 49
H: 1500 550 170 0.75 2500 63
MFD 250 220/1/50
L: 1100 400 130 0.58 1850 55

Dimension Information
A

Weight
Model A B C D E F
(Kg)

MFD 100 215 184 60 300 100 62 2.0


B

MFD 150 240 212 70 295 150 72 2.5

MFD 200 260 230 85 305 200 78 3.5


C
D MFD 250 300 290 92 385 250 119 7.5

All dimensions in mm.


E

Wiring Diagram
Ÿ Check that supply is according to data on Ÿ The equipment connected ground for motor
nameplate. protection according to the instructions - Unless the
Ÿ Insert cable according to the instructions in the guarantee isn’t accepted.
junction box and seal it. Ÿ Connect electric supply.

MCB Fan
Terminals N
Capacity FU AC ~ N 1
N
Blue 220-240V
L
Motor Black L High 50 Hz 2
Brown L Low
L 3
PE
Yellow Green 4

www.breeze.com.vn | breezefans@breeze.com.vn 53
Mixed Flow Inline Fan
MFD Series
We bring better air to life

Installation Method
Ÿ The fan is suitable both for horizontal or vertical
mounting on the wall or on the ceiling (Fig. 01- 03)
as one unit or included into connected in parallel or Airflow
in series sets (Fig. 04, 05).
Ÿ In case of the horizontal fan mounting install a min 1m
Fig 01
straight air ducts segment on side of the intake vent
not less than 1m.

Airflow
Fig 03

Fig 02

Ÿ In case of the vertical fan mounting


install an outer hood to prevent water
ingress inside the fan.
Fig 04 Fig 05
Ÿ The exhaust spigot must be
connected to the air duct.
Ÿ The fan mounting sequence is shown
in Fig. 06 - 12.

Fig 06
Fig 07 Fig 08

Fig 09 Fig 10 Fig 11 Fig 12

www.breeze.com.vn | breezefans@breeze.com.vn 54
Half Metal - Ceiling Mounted Fan
CMD Series
We bring better air to life

General Information
The CMD series is designed luxury half metal of ceiling
exhaust fan which use as ducted and unducted ceiling
mounted extractions. This style of fan is commonly used
in bathroom, bedroom, office, living room, store, toilets,
hotels and general exhaust applications.
The CMD series are offered with motor types:
Ÿ CMD-A series: AC motor.
Ÿ CMD-D series: DC motor.

Construction Information
The casing is made from half metal and powder coated.
Feature
The fans are fitted with high efficiency forward curve
Ÿ High efficiency.
centrifugal impeller driven with sealed for by long life
Ÿ Energy saving.
bearing.
Ÿ Low noise levels.
Ÿ Easy installation, service and clean.
The motor is made of 100% copper coil and fitted with
Ÿ Waterproof motor.
high quality ball bearing, high efficiency, low noise,
Ÿ Valve one-way.
maintenance free and long service life. Equipped with
Ÿ Be able to speed controllable.
thermal overload protection.
Ÿ Compact design. Testing
Ÿ Excellent for use with short run ducting. The performance has been tested in accordance with
Ÿ Fits into tight space. ISO 5801. The sound data has been determined by
Ÿ Standard motor range is protected to IP 44, testing to ISO 13347-2. The fans have passed QCVN
class B insulation. 04:2009/BKHCN (IEC 60335) standard for electric
safety.
Performance Curve
Pa CMD 160D Pa CMD 160A Pa CMD 210A

150 150 150


120 120 120
90 90 90
60 60 60
30 30 30
0 0 0
30 60 90 120 150 180 m3/h 30 60 90 120 150 180 m3/h 50 100 150 200 250 m3/h

Performance Parameters
Max. Max. Noise
Power Speed Voltage Installation Weight
Model Air Volume Pressure dBA
(W) (rpm/min) (V/P/Hz) (mm) (Kg)
(m3/h) (Pa) (at 3m)

CMD 160D 160 120 6 900 220/1/50 28 240x240 4.0

CMD 160A 160 120 22 1020 220/1/50 29 210X210 3.0

CMD 210A 210 150 30 1020 220/1/50 33 240X240 3.5

www.breeze.com.vn | breezefans@breeze.com.vn 55
Half Metal - Ceiling Mounted Fan
CMD Series
We bring better air to life

Dimension Information
E
B
Model A B C D E

CMD 160D 270 230 185 100 300


D

C
CMD 160A 245 205 185 100 275

CMD 210A 270 230 185 100 300


A
All dimensions in mm.
Wiring Diagram
MCB Fan
Ÿ Check that supply is according to data on nameplate. L
AC ~ L 1
Ÿ Insert electric wire according to the instructions in the 220-240V
N
50 Hz 2
terminal box.
Ÿ The equipment connected ground for motor protection N 3
according to the instructions. PE
4
Ÿ Connect electric supply.

Control Terminals Terminals


Black L Brown Black L Brown
FU FU
DC Red N Blue AC Red N Blue
Motor Motor
Capacity

Yellow Brown Yellow


Green Green
Yellow Green Yellow Green

Installation Method Ceiling joist Wooden frame

Ÿ Make a wooden frame and fix it on to the ceiling as picture Enhance piece

reference. Fig 1.
Ÿ Install and enclose the fan casing in the wooden frame, and
then fix it up firmly with 04 self-tapping screws.
Ÿ Connect the pipeline with the main part, and make it well-
sealed with the self-adhesive tape (bandage). (Fix the Fig 2.
ventilating pipeline onto the ceiling, keeping the ventilating
pipeline straight, without burden on the main part) no burden
Self-adhesive tape
on the pipeline.
Ÿ After connecting the power supply, turn on the switch, check
whether there is abnormal condition, and then place spring in Fig 3. Outlet duct
the slot hole to fix the panel.
Ÿ We must prevent the gas from the open airway or other firing
equipment from back flowing into the room.

Fig 4.

Louver Spring

www.breeze.com.vn | breezefans@breeze.com.vn 56
Full ABS - Ceiling Mounted Fan
CPD Series
We bring better air to life

General Information
The CPD series is a range of ceiling exhaust fan
designed for use as ducted and unducted ceiling
mounted extractions. This style of fan is commonly used
in bathroom, bedroom, office, living room, store, toilets,
hotels and general exhaust applications.

Construction Information
The casing and louver are made from injection moulded
by ABS polymer.
The fans are fitted with high efficiency forward curve
centrifugal impeller driven with sealed for by long life
bearing.
Feature The motor is made of 100% copper coil and fitted with
Ÿ High efficiency. high quality ball bearing, high efficiency, low noise,
Ÿ Low noise levels. maintenance free and long service life. Equipped with
Ÿ Easy installation, service and clean. thermal overload protection.
Ÿ Waterproof motor.
Testing
Ÿ Valve one-way.
Ÿ Be able to speed controllable. The performance has been tested in accordance with
Ÿ Compact design. ISO 5801. The sound data has been determined by
Ÿ Excellent for use with short run ducting. testing to ISO 13347-2. The fans have passed QCVN
Ÿ Fits into tight space. 04:2009/BKHCN (IEC 60335) standard for electric
Ÿ Standard motor range is protected to IP 44, safety.
class B insulation.

Performance Curve
Pa CPD 160 Pa CPD 210 Pa CPD 330

150 150 150


120 120 120
90 90 90
60 60 60
30 30 30
0 0 0
30 60 90 120 150 180 m3/h 50 100 150 200 250 m3/h 50 100 150 200 250 300 350 m3/h

Performance Parameters
Max. Max. Noise
Power Speed Voltage Installation Weight
Model Air Volume Pressure dBA
(W) (rpm/min) (V/P/Hz) (mm) (Kg)
(m3/h) (Pa) (at 3m)

CPD 160 160 120 22 1020 220/1/50 32 210X210 1.8

CPD 210 210 150 30 1020 220/1/50 34 240X240 2.0

CPD 330 330 150 36 750 220/1/50 36 270X270 2.8

www.breeze.com.vn | breezefans@breeze.com.vn 57
Full ABS - Ceiling Mounted Fan
CPD Series
We bring better air to life

Dimension Information

B Model A B C D E

D
C
CPD 160 245 205 180 100 275

CPD 210 270 235 180 100 300


E
CPD 330 300 265 210 150 330
A
All dimensions in mm.
Wiring Diagram
Ÿ Check that supply is according to data on nameplate. Ÿ The equipment connected ground for motor
Ÿ Insert electric wire according to the instructions in the protection according to the instructions.
terminal box. Ÿ Connect electric supply.

MCB Fan
Terminals L
Black L Brown AC ~ L 1
220-240V
FU N
Blue N Blue 50 Hz 2
Motor
Capacity
N 3
Brown Yellow PE
Green 4
Yellow Green

Installation Method
Ceiling joist
Ÿ Make a wooden frame and fix it on to the ceiling as picture Wooden frame
reference. Enhance piece
Ÿ Install and enclose the fan casing in the wooden frame, and
Fig 1.
then fix it up firmly with 04 self-tapping screws.
Ÿ Connect the pipeline with the main part, and make it well-
sealed with the self-adhesive tape (bandage). (Fix the
ventilating pipeline onto the ceiling, keeping the ventilating
Fig 2.
pipeline straight, without burden on the main part) no burden
on the pipeline.
Ÿ After connecting the power supply, turn on the switch, check Self-adhesive tape
whether there is abnormal condition, and then place spring in
the slot hole to fix the panel.
Ÿ We must prevent the gas from the open airway or other firing Fig 3. Outlet duct
equipment from back flowing into the room.
Wall
Constructor Duct Outlet
Louver Slot hole
Fan Fig 4.

Louver
Spring

www.breeze.com.vn | breezefans@breeze.com.vn 58
Wall Mounted Fan
AWC Series
We bring better air to life

General Information
The AWC series is a range of wall exhaust fans for
bathroom, shopping malls, hotels, living room, office,
store, laundries, toilet and general exhaust
applications. Available in four size to suit small and
large rooms.

Construction Information
The casing is used brand new good quality resin
material.
The fan is fitted with high efficiency axial impeller
driven by long life motor with sealed for life bearing.
Feature The motor is made of 100% copper coil and fitted with
Ÿ Low noise. high quality ball bearing, high efficiency, low noise,
Ÿ Easy installation, service and clean. maintenance free and long service life. Equipped with
Ÿ Waterproof motor. thermal overload protection.
Ÿ Be able to speed controllable. Testing
Ÿ By louver and automatic shutter
The performance has been tested in accordance with
Ÿ Compact design.
ISO 5801. The sound data has been determined by
Ÿ Can be installed directly on the wall.
testing to ISO 13347-2. The fans have passed QCVN
Ÿ Standard motor range is protected to IP44,
04:2009/BKHCN (IEC 60335) standard for electric
class B insulation.
safety.
Performance Curve
Pa AWC 15 Pa AWC 20

30 30

25 25

20 20

15 15

10 10

5 5

3 3
100 150 200 250 300 m /h 100 150 200 250 300 350 400 450 500 550 m /h

Pa AWC 25 Pa AWC 30

60 60

50 50

40 40

30 30

20 20

10 10

3 3
100 200 300 400 500 600 700 800 900 m /h 150 300 450 600 750 900 1050 1200 m /h

www.breeze.com.vn | breezefans@breeze.com.vn 59
Wall Mounted Fan
AWC Series
We bring better air to life

Performance Parameters

Max. Noise
Power Speed Voltage Installation Weight
Model Air Volume dBA
(W) (rpm/min) (V/P/Hz) (mm) (Kg)
(m3/h) (at 3m)

AWC 15 300 25 1390 220/1/50 35 205x205 2.0

AWC 20 560 30 1300 220/1/50 39 255x255 3.0

AWC 25 900 35 1200 220/1/50 45 305x305 4.0

AWC 30 1200 45 1000 220/1/50 49 355x355 4.5

Dimension Information
A
C

Model A B C

AWC 15 245 200 150


A
B AWC 20 295 250 150

AWC 25 345 300 150

AWC 30 400 350 150

All dimensions in mm.


Wiring Diagram
MCB Fan
Terminals L
Black L Brown AC ~ L 1
FU 220-240V
N
Motor Blue N Blue 50 Hz 2
Capacity
N 3
Brown Yellow
Green PE
Yellow Green 4

Installation Method
Ÿ Take care of direction of air flow shown by arrow
stickers. Frame
B
Ÿ Make a frame and install it to the wall. The sizes
of frame and hole refer to the above dimension Fitting Screw

sheet. B
Blade
Ÿ Install the fan with screws to the frame (refer to
the right picture).
Motor
Wall

Front cover Louver Secure Screw


Grille

www.breeze.com.vn | breezefans@breeze.com.vn 60
Plate Mounted Wall Fan
AWS Series
We bring better air to life

General Information
The AWS series are plate mounted wall fan with inlet
bellmouth.
Range sizes are fitted 250mm to 630mm diameter.
The AWS series offered reliable performance in
commercial and industrial exhaust air applications
suitable for wall installation providing good air flow
performance against medium level pressures.
Fans are used for ventilation of factory and
warehouses, restaurants, gymnasiums, meeting
rooms, workshops, swimming pools, green houses,
public toilet and stores, etc.
AWS series are offered with AC Voltage:
Ÿ E: Single-phase with 220V-240V/50Hz.
Feature
Ÿ D: Three-phase with 380V-415V/50Hz.
Ÿ High efficiency.
Ÿ Easy installation, service and clean. Construction Information
Ÿ Low power consumption. The AWS series are mainly constructed of casings
Ÿ Be able to speed controllable. with inlet cone plate (plate wall), impeller, motor,
Ÿ Fitted with terminal box. protection guard and terminal box.
Ÿ Compact design.
Casings are made of mild steel with power-coated
Ÿ Can be installed directly on the wall.
and anti- corrosion protection.
Ÿ Standard motor range is protected to IP54, class
The impellers are fitted with high efficiency sickle axial
F insulation.
impeller driven by external rotor motor and the motor
Testing impeller is balanced in according to ISO 1940 with
The performance has been tested in accordance G2.5mm/s quality standard.
with ISO 5801. The sound data has been The motor is made of 100% copper coil and fitted with
determined by testing to ISO 13347-2. The fans high quality ball bearing, waterproof, high efficiency,
have passed QCVN 04:2009/BKHCN and TCVN low noise, maintenance free and long service life.
5699-2-80:2007 (IEC 60335) standard for electric Equipped with thermal overload protection.
safety. Inlet wire guards are supplied for all sizes.

Performance Curve
AWS 250-4E/D Pa
AWS 315-4E/D
Pa

80 80
70 70
60 60
50 50
40 40
30 30
20 20
10 10
0 3 0 m3/h
m /h
200 400 600 800 1000 1200 600 800 1000 1200 1400 1600 1800 2000

www.breeze.com.vn | breezefans@breeze.com.vn 61
Plate Mounted Wall Fan
AWS Series
We bring better air to life

Pa AWS 355-4E/D AWS 400-4E/D


Pa

90 180
80 160
70 140
60 120
50 100
40 80
30 60
20 40
10 20
0 0 m3/h
m3/h
500 1000 1500 2000 2500 3000 500 1000 1500 2000 2500 3000 3500 4000

Pa AWS 450-4E/D Pa AWS 500-4E/D

180 180
160 160
140 140
120 120
100 100
80 80
60 60
40 40
20 20
0 3
m /h 0 m3/h
500 1000 1500 2000 2500 3000 3500 4000 4500 5000 1000 2000 3000 4000 5000 6000 7000

Pa AWS 560-4E/D Pa AWS 560-6E/D

180 90
160 80
140 70
120 60
100 50
80 40
60 30
40 20
20 10
3
m /h 0 m3/h
1000 2000 3000 4000 5000 6000 7000 8000 9000 1000 2000 3000 4000 5000 6000 7000

Pa
AWS 630-4E/D Pa
AWS 630-6E/D

250 180
225 160
200 140
175 120
150 100
125 80
100 60
75 40
50 20
0 0
m3/h m3/h
5000 7000 9000 11000 13000 3000 4000 5000 6000 7000 8000 9000 10000

www.breeze.com.vn | breezefans@breeze.com.vn 62
Plate Mounted Wall Fan
AWS Series
We bring better air to life

Performance Parameters
Max. Max. Noise
Power Currency Speed Voltage Capacity
Model Air Volume Pressure dBA
(W) (A) (rpm/min) (V/P/Hz) ( F)
(m3/h) (Pa) (at 3m)
AWS 250-4E 1250 70 50 0.25 1450 220/1/50 2.5 50

AWS 250-4D 1250 70 50 0.23 1450 380/3/50 - 50

AWS 315-4E 1750 70 75 0.35 1400 220/1/50 2.5 52

AWS 315-4D 1750 70 70 0.25 1400 380/3/50 - 52

AWS 355-4E 2650 80 120 0.57 1400 220/1/50 4 60

AWS 355-4D 2650 80 120 0.45 1400 380/3/50 - 60

AWS 400-4E 3800 160 190 0.9 1400 220/1/50 6 62

AWS 400-4D 3800 160 180 0.6 1400 380/3/50 - 62

AWS 450-4E 5000 150 280 1.25 1380 220/1/50 8 64

AWS 450-4D 5000 150 210 0.75 1380 380/3/50 - 64

AWS 500-4E 6800 170 370 1.75 1390 220/1/50 10 67

AWS 500-4D 6800 170 380 0.8 1390 380/3/50 - 67

AWS 560-4E 8200 180 550 2.6 1380 220/1/50 12 69

AWS 560-4D 8200 180 520 0.95 1380 380/3/50 - 69

AWS 560-6E 6500 80 320 1.5 950 220/1/50 8 63

AWS 560-6D 6500 80 300 1.0 950 380/3/50 - 63

AWS 630-4E 13000 200 800 3.7 1380 220/1/50 15 70

AWS 630-4D 13000 200 760 1.6 1380 380/3/50 - 70

AWS 630-6E 10000 150 550 1.9 930 220/1/50 10 65

AWS 630-6D 10000 150 520 1.35 930 380/3/50 - 65

Dimension Information

A Weight
4OE Model A B C D E (Kg)

AWS 250-4E/D 370 320 100 258 7 4

AWS 315-4E/D 430 380 118 315 9 6


D

AWS 355-4E/D 485 435 130 359 9 8

AWS 400-4E/D 540 490 138 400 9 10

AWS 450-4E/D 575 535 148 456 11 11


C
B AWS 500-4E/D 655 615 153 509 11 15

AWS 560-4E/D 725 675 167 563 11 18

AWS 560-6E/D 725 675 167 563 11 18

AWS 630-4E/D 805 750 185 639 11 23

AWS 630-6E/D 805 750 185 639 11 23


All dimensions in mm.

www.breeze.com.vn | breezefans@breeze.com.vn 63
Plate Mounted Wall Fan
AWS Series
We bring better air to life

Wiring Diagram
Reversible in single phase

Terminals Terminals
Black L Brown Brown L Brown
FU FU
Motor Blue N Blue Motor Blue N Blue
Capacity Capacity

Brown Yellow Black Yellow


Green Green
Yellow Green Yellow Green

In the case of reverse direction of


rotation: MCB Fan MCB Fan
AC ~ L L1 U
Ÿ With 1 phase motor to change direction L 1 Black 1
220-240V AC ~
of rotation, transpose the position of 50 Hz N
380-415V
L2 V
2 Blue 2
leads black and brown. 50 Hz
L3 W
N 3 Brown 3
Ÿ With 3 phases motor to change
PE PE Yellow
direction of rotation transpose two of 4 Green
the phases.

Installation Method
Take care of direction of air flow shown by arrow stickers.
1. Make a frame and install it to the wall. The sizes of
frame and hole refer to the above dimension sheet.
2. Install the fan with screws to the frame (refer to the
right picture).

Wall
Fig 01 Fig 02
Frame for Installation
(by Contractor)

Rain Hood

Inside Outside

Fig 03

Frame view
Installation overview
with weather cover Fig 04

www.breeze.com.vn | breezefans@breeze.com.vn 64
Industrial Wall Fan
AWF Series
We bring better air to life

General Information
AWF series are offered reliable performance in industrial
exhaust wall fan application suitable for factory and
warehouse, livestock farms, agricultural flower greenhouses,
industrial plants, such as ventilation, cooling and ventilation.

Construction Information
Frame: High quality thick galvanized plate 1.2mm and zinc
275g/m2, high strength, strong corrosion resistance.
Impeller: 304 of 6-blade stainless steel is beautiful and
durable, through dynamic balance test, large volume and low
noise, no deformation and no fracture.
They have thickness with 1.2 mm and a self-cleaning stainless
steel material made by stamping, no dust, beautiful and
durable. The special shape of the blade design ensures large
volume, no deformation, not broken.
Motor: High quality (TEFC). The voltage and frequency can
be customized. Standard range is IP 55, insulation class F.
Bearing: High quality Japan ball bearing with special
waterproof design, water can’t enter, high strength, low noise,
maintenance free and long service life.
Pulley: High strength aluminum magnesium alloy hot
molding, light weight and high strength.
Belt: High quality Japan belt such as Mitsuboshi, etc.
Weight: Using high strength nylon swing open shutter
opening and closing device, flexible and stable.
Tensioning mechanism:
The automatic belt tensioner to ensure efficiency and good
performance of the most advanced.

Performance Curve
AWF 750 AWF 1100 AWF 1250
Pa Pa Pa

50 50 50

40 40 40

30 30 30

20 20 20

10 10 10
18000

20000

22000

24000

26000

32000

33000

34000

35000

36000

37000

39000

41000

43000

45000

m3/h m3/h m3/h

www.breeze.com.vn | breezefans@breeze.com.vn 65
Industrial Wall Fan
AWF Series
We bring better air to life

Performance Parameters

Max. Noise
Power RPM RPM Voltage Dimension Weight
Model Air Volume dBA
(kW) Fan Motor (V/P/Hz) (mm) (Kg)
(m3/h) (at 3m)

AWF 750 25000 0.55 650 1440 380/3/50 900x900x400 66 65

AWF 1100 36000 0.75 560 1440 380/3/50 1220x1220x400 85 68

AWF 1250 45000 1.1 440 1440 380/3/50 1380x1380x400 96 72

Dimension Information

Model A B C D E F G

AWF 750 900 400 450 100 130 300 295


B

G G
M8 AWF 1100 1220 400 610 100 130 280 260
M8
E

AWF 1250 1380 400 690 100 130 210 220

All dimensions in mm.


A B B
D
F
C

E M8
A

M8
F

www.breeze.com.vn | breezefans@breeze.com.vn 66
Extraction Selection
Calculating Extraction Rates
We bring better air to life

Converting Litres/second (L/s) Working out the right fan for the job
3
and Cubic Metres/hour (M /hr) Ÿ Calculate the room volume in metres (L x W x H).
3
(Note: 1M = 1000 Litres) Ÿ Multiply the room volume by the recommended air

If you know the Litres/second (L/s): changes per hour for that room. Always use the
higher limit.
L/s x 3.6 = m³/hr. (e.g. 25 L/s x 3.6 = 90m³/hr).
Ÿ The result is the total performance required in cubic
metres per hour.
If you know the Cubic Metres/hour (m³/hr):
Select a fan with a higher performance than this
m³/hr ÷ 3.6 = L/s. (e.g. 200m³/hr ÷ 3.6 = 55.55 L/s).
figure.
Note: Example:
Stated extraction rates are “free air” values and do What is the best fan for a bathroom that is 2.8m long
not account for grille type or duct run restrictions. by 2.8m wide with a ceiling height of 2.4m?
Calculate the volume of the bathroom: 2.8 x 2.8 x 2.4
Air changes per hour (ACH) 3
= 18.8m .
The number of times the total room volume of air is 11-15 air changes per hour are recommended for a
changed each hour. Refer to the table below for the bathroom. Multiply the room volume by 15: 18.8m3 x
recommended Air Changes per hour based on the 15 = 282m3/hr.
room type. The fan to choose for this bathroom would be a fan
that performs at greater than 282m3/hr.
Application Description Air Changes Per Hour A fan that has a performance level of 313m /hr or
3

Bathrooms 11 - 15 higher (e.g. XP150, or SF150) would do this job.

Kitchens - (domestic) 15 - 20 Quick cross-reference calculations


Laundries - (no drier) 6 - 10 Convert from one to other types of measurement:
Laundries - (with drier) 10 - 30 Known To Find Action
Toilets 6 - 10
L/s m³/hr L/s x 3.6 =m³/hr
Bedroom 2-5
m³/hr L/s m³/hr ÷ 3.6 = L/s
Offices 6 - 10
cfm m³/hr cfm x 1.69 =m³/hr
Cafés 10 - 12
cfm L/s cfm x 0.47 = L/s
Canteens 8 - 12
240
Garages 6-8 400 110 m³/hr to L/s to cfm
220 Comparison Chart
100
Kitchens - (commercial) 20 - 30 350
200
90
Restaurants 8 - 12 300 180
80
160
Factories 8 - 10 250 70
140
Stores & Warehouses 3-6 60
200 120
Libraries 3-5 50
100
150 40
Classroom 5-7 80
100 30
60
Toilet Public 15-20
20 40
50
Smoking Room 12-15
10 20
0
m3/hr L/s cfm

www.breeze.com.vn | breezefans@breeze.com.vn 67
WE BRING
BETTER AIR
TO LIFE

Applied standard:

BREEZE INDUSTRIAL VENTILATION JOINT STOCK COMPANY


Vietnam Singapore Myanmar
Head Office: Office: Office:
215D8 Nguyen Van Huong Street, Thao Dien Ward, No 15, Yishun Industrial No.13/B, Kan Yeik Thar
District 2, Ho Chi Minh City, Vietnam. Street 1, #03-29, WIN5 Street, Thingangyun
Tel: +84 28 6651 8585 | Hotline: +84 931 920 368 Singapore S768091. Township, Yangon,
Factory: Tel: +65-6254-2648 Myanmar.
12 Road No. 570, Xom Moi Hamlet, Trung Lap Ha
Commune, Cu Chi District, Ho Chi Minh City,
Vietnam.
Tel: +84 28 6659 9589
Ha Noi Office:
55, Alley No. 14, Vu Huu Street, Thanh Xuan Bac
Ward, Thanh Xuan District, Ha Noi City, Vietnam.
Tel: +84 24 6683 8797 | Hotline: +84 906 568 557.
Website: www.breeze.com.vn
Email: breezefans@breeze.com.vn

You might also like