0% found this document useful (0 votes)
58 views5 pages

LR6 Specification 380min

The document provides technical specifications for alkaline batteries from Microcell International Battery Co., including: 1) Dimensions and chemical composition of AA batteries. 2) Electrical characteristics showing minimum voltages and currents for fresh and 12-month old batteries under various loads and temperatures. 3) Minimum average discharge times for batteries under different loads and conditions. 4) Safety and storage requirements, including no leakage, explosion, or degradation over 5 years.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
58 views5 pages

LR6 Specification 380min

The document provides technical specifications for alkaline batteries from Microcell International Battery Co., including: 1) Dimensions and chemical composition of AA batteries. 2) Electrical characteristics showing minimum voltages and currents for fresh and 12-month old batteries under various loads and temperatures. 3) Minimum average discharge times for batteries under different loads and conditions. 4) Safety and storage requirements, including no leakage, explosion, or degradation over 5 years.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 5

MICROCELL INTERNATIONAL BATTERY CO.

,LTD.
Address:No.173, Zhongxin Avenue, SIP, Suzhou, Jiangsu, China
Web: www.micropower-battery.com Email: yuki@micropowerbattery.com

TECHNICAL SPECIFICATION

1. About
Alkaline battery
Model# : LR6 /AA

A
Dimensions(GB):
A:1.5-1.7mm C:13.7-14.5mm

B
B:49.5-50.5mm D:0.5-0.8mm

D
Chemical System: Zn/KOH—H2O/MnO2
Nominal voltage: 1.5V
Average weight: 23.2~23.5g C
Jacket: Foil Label
Reference document: IEC60086-2:2021, IEC60086-5: 2016, GB/T8897.2-2021, GB8897.5-2013
Heavy Metal Contents: 0% Hg & Cd

2. Rating
Standard Temperature 20℃±2℃
Temperature Range for operation Special Temperature 30℃±2℃
High temperature 45℃±2℃
Standard Humidity 35%~75%
Humidity Range for Storage
Special Humidity 35%~65%
Diameter 14.1~14.3mm
Dimension
Height 50~50.3mm

3. Electrical Characteristic
(condition: on-load resistance 3.9Ω,precision±0.5%,time:0.3S, temperature: 20℃±2℃。
Testing should be done within 30days upon the receipt of goods. )

Off-load Voltage On-load Voltage Instantaneous current

fresh Battery ≥1.610V ≥1.470V ≥8.0A


after12 months under Room Temp ≥1.600V ≥1.420V ≥7.0A

4. Discharge Characteristic
(condition: temperature: 20℃±2℃. Testing should be done within 30days upon the receipt of goods)
Discharge condition Minimum average Discharge time
MICROCELL INTERNATIONAL BATTERY CO.,LTD.
Address:No.173, Zhongxin Avenue, SIP, Suzhou, Jiangsu, China
Web: www.micropower-battery.com Email: yuki@micropowerbattery.com

on-load After 12 months under


Discharge time per day end Voltage fresh Battery
resistance Room Temp
1.5w-0.65w 2s/28s,5m/h 1.05V 85pulse 75pulse
3.9Ω 4min/h, 8h/d 0.9V 7.0h 6.44h
3.9Ω 1h/d 0.8V 480min 450min
250mA 1h/d 0.9V 8.0h 7.3h
100mA 1h/d 0.9V 23.5h 21h
50mA 1h/8h, 24h/d 1.0V 47.5h 43.5h
1000mA 10s/min,1h/d 0.9V 450pulse 410pulse
43Ω 4h/d 0.9V 93h 90h
3.9Ω 24h/d 0.9V 380-400min 365min
Capacitance: 2800mAH (S.T. 25mA constant-current discharge to 0.8 V)
(Inspect standard: discharge 9 sample-batteries for each condition. It passes when average discharge time is no less than

Rated Time and the quantity of the batteries which the value is under 80% of Rated Value is no more than one)

5.Anti-leakage characteristic
Item Condition Period Characteristic Inspect standard
Anti-leakage Feature of on-load:10Ω continuously discharge Deformation is less N=9, AC=0,
over-discharge temp: 20℃±2℃。 to 0.6V than 0.2mm and Re=1
Humidity: 55±20RH no visual leakage
feature of storage tenp60℃±2℃ ≥30 days N=30, AC=0,
Humidity :≤90%RH Re=1

6. Safety
Item Condition Period Characteristic Inspect standard

anti-short-circuit Temp:20℃±2℃ 24hours no explosion N=5,Ac=0,Re=1

7. Marks:
The following marks will be printed or stamped on the body
(1) Model
(2) Nominal Voltage
(3) pole
(4) Warning
(5) Manufactured Date /Exp date

8.Storage life
Under room temp & suitable environment, its shelf time is 5 years.

9. Discharge diagram
MICROCELL INTERNATIONAL BATTERY CO.,LTD.
Address:No.173, Zhongxin Avenue, SIP, Suzhou, Jiangsu, China
Web: www.micropower-battery.com Email: yuki@micropowerbattery.com

a)Load Resistance:3.9Ω ,Discharge Pattern:24h/day , End Voltage:0.90V, Temperature:20℃±2℃

b)Load Resistance:3.9Ω ,Discharge Pattern:1h/day, End Voltage:0.80V, Temperature:20℃±2℃

c)Load Resistance:24Ω, Discharge Pattern:8h/day,15s/m, End Voltage:0.90V,Temperature:20℃±2℃


MICROCELL INTERNATIONAL BATTERY CO.,LTD.
Address:No.173, Zhongxin Avenue, SIP, Suzhou, Jiangsu, China
Web: www.micropower-battery.com Email: yuki@micropowerbattery.com

d)Load Resistance:100mA, Discharge Pattern:1h/day, End Voltage:0.90V, Temperature:20℃±2℃

e)Load Resistance:1000mA, Discharge Pattern:1h/day,10s/m, End Voltage:0.90V,


MICROCELL INTERNATIONAL BATTERY CO.,LTD.
Address:No.173, Zhongxin Avenue, SIP, Suzhou, Jiangsu, China
Web: www.micropower-battery.com Email: yuki@micropowerbattery.com

Temperature:20℃±2℃

f)Load Resistance:1.5W, Discharge Pattern:2s/28s,5m/h, End Voltage:0.90V, Temperature:20℃±2℃