0% found this document useful (0 votes)
270 views16 pages

KENDO High Static Ducted AC Units

This document describes Kendo high static ducted air conditioning units for commercial and industrial applications. It offers a wide range of indoor units from 8-60 HP and outdoor units from 8-20 HP. The units have flexible installation options, high efficiency heat exchangers, and intelligent controllers. They are suitable for both horizontal and vertical air discharge applications.

Uploaded by

LAB DONKAS
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
270 views16 pages

KENDO High Static Ducted AC Units

This document describes Kendo high static ducted air conditioning units for commercial and industrial applications. It offers a wide range of indoor units from 8-60 HP and outdoor units from 8-20 HP. The units have flexible installation options, high efficiency heat exchangers, and intelligent controllers. They are suitable for both horizontal and vertical air discharge applications.

Uploaded by

LAB DONKAS
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 16

HIGH STATIC DUCTED

| WIDE RANGE OF PRODUCT


KENDO High Static Ducted units are designed for air-conditioning system in commercial and industrial application
comprises various model with complete range of equipment from 8hp to 60.0 hp for indoor units and 8hp to 20hp for outdoor
units.

Single Skin Indoor Unit (8 ~ 15hp) Outdoor Unit (8hp) Outdoor Unit (10hp & 12.5hp)

Double Skin Indoor Unit (20 ~ 60hp) Outdoor Unit (20hp) Outdoor Unit (15hp)

| STRONG AIR FLOW |HIGH PERFORMANCE


A belt driven drive package (12.5Hp indoor and above) offer SCROLL COMPRESSOR
flexibility on various air flow rate and various static pressure application. Adopting very famous brand with
Design with high external static pressure to make sure the air a special low noise, low vibration and high
distribution is even to every corner with long ducting application. performance scroll compressor. Possesses a
Flexible changing the external static pressure and air flow by high Energy Efficiency Ratio (EER) delivering
adjusting the 3 fan speed (8.0 ~ 10.0 hp) or changing the pulley size exceptional performance with a reduction in
(12.5 ~ 60.0 hp) provide more flexibility in installation and produce energy consumption. 100% gas cooler motor
optimum cooling and comfort. with internal line breaker or solid state motor

Vertical Blow
protectors.
Vertical Blow
(Optional) (10 - 15hp)

Horizontal Horizontal Scroll


Return Air Blow Blow Compressor

(Standard) (10 - 12.5hp)

Indoor Unit Outdoor Unit

| FLEXIBLE APPLICATION & |HIGH QUALITY CASING


INSTALLATION The indoor casing is constructed with powder coated
The indoor and outdoor unit allows you to choose electro galvanized mild steel sheet and insulated with 1/2”
the air discharge direction for either horizontal or vertical air (13mm) thick 24kg/m3 PE foam (8.0 ~ 15.0hp) or 1” (25mm)
discharge application (Optional). This package is optional thick double skin panel injected with polyure-thane foam (PU)
and need to confirm before do the ordering. insulation with “K” value of 0.02Watt/°C

2
|HIGH EFFICIENCY HEAT EXCHANGER Flow Master Series

Each coil consist of staggered row of 3/8” OD seamless copper tubes, mechanically
expanded into die-formed aluminum fins.
The evaporator coil come standard with hydrophilic coated fin to ensure optimum system
effectiveness and durability.
The condenser coil provided with integral sub-cooling circuit to maximize energy
efficiency and promote superior match-system operating performance when connected to
suitable sized DX Evaporator-Blower unit.
Coils are leak and pressure tested to 450psig while storage pressure is keep at 100 Psig.

|SAFETY FEATURES |AIR FILTER


Built in internal overload The Indoor unit come
protection for compressor. All with washable synthetic fibre
outdoor units are equipped with air filter. Designed with easy
auto reset high pressure and withdrawal and renewal of filter
low pressure cut-out to protect cells. HEPA, AAF and many type
against compressor damage of air filter can be requested
due to high head pressure and to meet the requirement and
Outdoor unit control circuit
system leakage respectively. building application.
Washable Air Filter
*Phase sequencer, overload and delay timer is optional.

| PART LOAD WITH MULTI CIRCUIT DESIGN


The unit has single (8.0 ~ 15.0 hp) and multiple hermetic scroll compressors (20.0 ~ 60.0 hp) with independent refrigerant
circuit.
Each refrigerant circuit consists of a high efficiency compressor and condenser. With this modular system configuration
combining with microprocessor controller allows the units to operate under partial load condition to meet the cooling capacity
demand.
No total shut down when servicing or repairing a faulty compressor or outdoor units.

Single Stage Controller


Single Condensing Unit Indoor Unit (8 ~ 15hp)

Sequential Controller
In a OUTDOOR MODULAR SYSTEM, any faulty unit
can be shut down and the remaining units c
 an keep Indoor Unit (20 ~ 60hp)

on working.

| INTELLIGENT CONTROLLER (STANDARD)


All the features can be easily set and change through microprocessor controller. It ensures comfortable cooling is delivered
to the user with user friendly wired keypad controller.
Wide range of control features including mode, temperature setting, timer, self diagnosis error code and etc.

Commercial Air Conditioner 3


Indoor Unit Specification (R22)

Conditions: 1) Nominal cooling capacities are based on the following conditions : Indoor 26.7°C DB, 19.4 °C WB, Outdoor 35°C DB.
2) All specifications are subjected to change by manufacturer without prior notice.

4
Flow Master Series
Indoor Unit Specification (R407c)

Conditions: 1) Nominal cooling capacities are based on the following conditions : Indoor 26.7°C DB, 19.4 °C WB, Outdoor 35°C DB.
2) All specifications are subjected to change by manufacturer without prior notice.

Commercial Air Conditioner 5


Indoor Unit Specification (R410a)

6
Outdoor Unit Specification (R22) Flow Master Series

Outdoor Unit Specification (R407c)

Outdoor Unit Specification (R410a)

Conditions: 1) Nominal cooling capacities are based on the following conditions : Indoor 26.7°C DB, 19.4 °C WB, Outdoor 35°C DB.
2) All specifications are subjected to change by manufacturer without prior notice.

Commercial Air Conditioner 7


MULTI SPLIT 1 to 2 (Single Condenser)
| WIDE RANGE OF PRODUCT
KENDO High Static Ducted multi split units are designed for air-conditioning system in commercial and industrial
application. This unit has multiple hermetic compressors with independent refrigerant circuit in single foaming condenser coil.

Indoor Unit High Static Ducted

Outdoor Unit Multi Split (Single Coil)

| STRONG AIR FLOW | HIGH PERFORMANCE


Each coil consist of staggered row of 3/8” OD seamless copper SCROLL COMPRESSOR
tubes, mechanically expanded into die-formed aluminum fins.The Adopting very famous brand with
evaporator coil come standard with hydrophilic coated fin to ensure a special low noise, low vibration and high
optimum system effectiveness and durability.The condenser coil performance scroll compressor. Possesses a
provided with integral sub-cooling circuit to maximize energy efficiency high Energy Efficiency Ratio (EER) delivering
and promote superior match-system operating performance when exceptional performance with a reduction in
connected to suitable sized DX Evaporator-Blower unit. Coils are leak energy consumption. 100% gas cooler motor
and pressure tested to 450psig while storage pressure is keep at 100 with internal line breaker or solid state motor
Psig. protectors.

Scroll Compressor

| SLIM INDOOR DESIGN | HIGH QUALITY CASING


The indoor casing is constructed with powder coated electro The indoor and outdoor casing is
galvanized mild steel sheet and insulated with 1/2” (13mm) thick 24kg/m constructed with powder coated electro
PE foam. Slim indoor design with body height 17.5” (440mm). The galvanized mild steel sheet and insulated with
internal vents are easily accessible by removing the service panels. 1/2” (13mm) thick 24kg/m3 PE foam

8
| SAFETY FEATURES
Flow Master Series
| AIR FILTER
Built in internal overload The Indoor unit come
protection for compressor. All washable synthetic fibre air
outdoor units are equipped with filter. Designed with easy
auto reset high pressure and withdrawal and renewal of
low pressure cut-out to protect filter cells. HEPA,AAF and
against compressor damage many type of air filter can
due to high head pressure and be requested to meet the
Outdoor unit control circuit
system leakage respectively requirement and building
Washable Air Filter
application.
*Phase sequencer, overload and delay timer is optional.

| PART LOAD WITH MULTI CIRCUIT DESIGN


The unit has multiple hermetic scroll compressors with independent refrigerant circuit in single foaming condenser coil.
Each refrigerant circuit consists of a high efficiency compressor and condenser. With this modular configuration combining with
microprocessor controller allows the units to operate under partial load condition to meet the cooling capacity demand.

Outdoor Unit Multi Split(Single Coil) Indoor Unit High Static Ducted Sequential Controller

| INTELLIGENT CONTROLLER (OPTIONAL)


All the features can be easily set and change through microprocessor controller. It ensures comfortable cooling is
delivered to the user with user friendly wired keypad controller. Wide range of control features including mode, temperature
setting, timer, self diagnosis error code and etc.

Commercial Air Conditioner 9


Indoor Unit Specification

Outdoor Unit Specification

Conditions: 1) Nominal cooling capacities are based on the following conditions : Indoor 26.7°C DB, 19.4 °C WB, Outdoor 35°C DB.
2) All specifications are subjected to change by manufacturer without prior notice.
3) For R410a Series, please contact manufacturer.

10
ROOFTOP PACKAGED UNIT
| PRODUCT INTRODUCTION Flow Master Series

KENDO Rooftop Packaged Air Conditioners are designed and manufactured to meet the requirements of the severe
climatic conditions and are built specifically for outdoor installations, either on ground or roof level.
The Rooftop Packaged Air Conditioners are ideal for warehouses, large halls, schools, residences, or wherever the
requirement is for a heavy duty unit with a hermetic scroll compressor.
The units are available from 8Hp to 32Hp nominal (24kW to 100kW) in 50Hz. This Rooftop Packaged Air Conditioners are
completely assembled, internally wired, charged with refrigerant at factory, tested before ship and ready for installation.
All that is required on site is connecting ducting and power supply. This greatly reduces installation work and costs.

TYPICAL INSTALLATION

Roof Top Level Installation

Ground Level Installation

Commercial Air Conditioner 11


| STRONG AIR FLOW | HIGH PERFORMANCE
SCROLL COMPRESSOR
Design with high air flow and high external static pressure to
make sure the air distribution is even to every conner with long ducting Adopting very famous brand with
application. a special low noise, low vibration and high
Direct-driven forward curved centrifugal fan are used to d
 eliver an performance scroll compressor. Posseses a
accurate air flow at low noise level. high Energy Efficiency Ratio (EER) delivering
exceptional performance with a reduction in
Condenser Hot Air
energy consumption. 100% gas cooler motor
with internal line breaker or solid state motor
Cool Air protectors.
Supply
Embient Air

Return Air

Condenser Evaporator
Side Side

Scroll Compressor

|SAFETY FEATURES |AIR FILTER


Built in internal overload The Indoor unit come
protection for compressor. All with washable synthetic fibre
outdoor units are equipped with air filter. Designed with easy
auto reset high pressure and withdrawal and renewal of filter
low pressure cut-out to protect cells. HEPA, AAF and many type
against compressor damage of air filter can be requested
due to high head pressure and to meet the requirement and
Outdoor unit control circuit
system leakage respectively. building application.
Washable Air Filter

*Phase sequencer, overload, wired controller and delay timer is optional.

| INTELLIGENT CONTROLLER (OPTIONAL)


All the features can be easily set and change through microprocessor controller. It ensures
comfortable cooling is delivered to the user with user friendly wired keypad controller. Wide range
of control features including mode, temperature setting, timer, self diagnosis error code and etc.

12
Flow Master Series

Unit Specification (R22)

Conditions: 1) Nominal cooling capacities (1) are based on the following conditions : Indoor 26.7°C DB, 19.4 °C WB, Outdoor 35°C DB.
Nominal cooling capacities (2) are based on the following conditions : Indoor 26.7°C DB, 19.4 °C WB, Outdoor 46.1°C DB.
2) Refrigerant charge volumes are factory charged.
3) The range of working voltage is within +10% from rated voltage
4) All specifications are subjected to change by manufacturer without prior notice.

Commercial Air Conditioner 13


Unit Specification (R407c)

Conditions: 1) Nominal cooling capacities (1) are based on the following conditions : Indoor 26.7°C DB, 19.4 °C WB, Outdoor 35°C DB.
Nominal cooling capacities (2) are based on the following conditions : Indoor 26.7°C DB, 19.4 °C WB, Outdoor 46.1°C DB.
2) Refrigerant charge volumes are factory charged.
3) The range of working voltage is within +10% from rated voltage
4) All specifications are subjected to change by manufacturer without prior notice.

14
Flow Master Series

Nomenclature

Commercial Air Conditioner 15

You might also like