SLCM – CALIBRATION CERTIFICATE
Calibration Report Ref : SZ/NGR/2022-23       Model & Machine S. No.: ARGO-4300 &
                                              AF1ARG48CKM000643
Date of Calibration      : 13/05/2023          HMR- 74
 Customer: SHRI MAHADEV & COMPANY              Calibration valid till: 17.11.2023
                      Calibration procedure carried
                        1. Tarring: Procedure mentioned in the manual.
                         2. Calibration: As mentioned below.
                      IN LOADING BUCKET:
SLNO     ACTUALWEIGHT                   DISPLAYED                             DIFFERENCE IN WEIGHT
         (KGS)                          WEIGHT (KGS)                       (KGS)             %
                                                                                           ERROR
   1          300                                  300                              0      0.0%
   2          250                                  250                              0      0.0%
   3          200                                  200                              0      0.0%
   4          150                                  150                              0      0.0%
   5          100                                  100                              0      0.0%
   6           50                                   50                              0      0.0%
             Carried out by:
                           Service Engineer              Code:
                        MR. Virender Yadav             903141
                                                                   Hydrotech Equipment Pvt Ltd
                                              (Authorized Dealer for AJAX Engineering Private limited)
                                                                Approved By:
                                                                     MANAGER – SERVICE Signature