CD 100
CD 100
API093050
CD 100+
Atlas Copco
            CD 100+
            API093050
            Instruction book
            Original instructions
            COPYRIGHT NOTICE
            Any unauthorized use or copying of the contents or any part thereof is prohibited.
            This applies in particular to trademarks, model denominations, part numbers and
            drawings.
            This instruction book is valid for CE as well as non-CE labelled machines. It meets the
            requirements for instructions specified by the applicable European directives as
            identified in the Declaration of Conformity.
2017 - 08
www.atlascopco.com
                                                                                                                                 Instruction book
Table of contents
1 Safety precautions..........................................................................................................4
2 General description........................................................................................................ 9
2.2 OPERATION.....................................................................................................................................10
3 Electrical diagram.........................................................................................................15
4 Installation.....................................................................................................................17
5 Electrical connections..................................................................................................21
6 Operating instructions................................................................................................. 24
7 Maintenance.................................................................................................................. 26
7.1 MAINTENANCE................................................................................................................................. 26
8 Problem solving............................................................................................................29
9 Technical data...............................................................................................................30
2                                                                                                                                      API093050
Instruction book
13 Declaration of conformity............................................................................................ 34
API093050                                                                                                                                        3
                                                                                                  Instruction book
1 Safety precautions
Explanation
Danger to life
Warning
Important note
General precautions
                         All responsibility for any damage or injury resulting from neglecting these precautions, or
                         non-observance of the normal caution and care required for installation, operation,
                         maintenance and repair, even if not expressly stated, will be disclaimed by the
                         manufacturer.
4                                                                                                      API093050
Instruction book
API093050                                                                                                   5
                                                                                                Instruction book
       17. If the maximum pressure of the compressor is higher than the design pressure of the dryer,
           a full flow safety valve must be installed between the compressor and the dryer in order to
           blow off the excessive pressure in case the safety valve of the dryer should be out of order
           or blocked.
       18. When unit is not permanently secured to the floor in the vertical position or mounted
           horizontally, access to electrical equipment is feasible through the unit base. In this case
           additional barriers must be provided during installation. Tag with "warning high voltage"
           symbol
                      Also consult following safety precautions: Safety precautions during operation and Safety
                      precautions during maintenance or repair.
                      These precautions apply to machinery processing or consuming air or inert gas. Processing
                      of any other gas requires additional safety precautions typical to the application which are
                      not included herein.
                      Some precautions are general and cover several machine types and equipment; hence
                      some statements may not apply to your machine.
6                                                                                                    API093050
Instruction book
                       Also consult following safety precautions: Safety precautions during installation and Safety
                       precautions during maintenance or repair.
                       These precautions apply to machinery processing or consuming air or inert gas. Processing
                       of any other gas requires additional safety precautions typical to the application which are
                       not included herein.
                       Some precautions are general and cover several machine types and equipment; hence
                       some statements may not apply to your machine.
API093050                                                                                                       7
                                                                                             Instruction book
    18. Make sure that all sound-damping material and vibration dampers, e.g. damping material on
        the bodywork, is in good condition. If damaged, replace it by genuine material from the
        manufacturer to prevent the sound pressure level from increasing.
    19. Never use caustic solvents which can damage materials of the air net, e.g. polycarbonate
        bowls.
    20. The following safety precautions are stressed when handling refrigerant:
           • Never inhale refrigerant vapours. Check that the working area is adequately ventilated;
             if required, use breathing protection.
           • Always wear special gloves. In case of refrigerant contact with the skin, rinse the skin
             with water. If liquid refrigerant contacts the skin through clothing, never tear off or
             remove the latter; flush abundantly with fresh water over the clothing until all refrigerant
             is flushed away; then seek medical first aid.
    21. The following safety precautions are stressed when handling desiccant:
           • Take precautions not to inhale desiccant dust.
           • Check that the working area is adequately ventilated; if required, use breathing
             protection.
           • Do not overfill the dryer when replacing desiccant.
                   Also consult following safety precautions: Safety precautions during installation and Safety
                   precautions during operation.
                   These precautions apply to machinery processing or consuming air or inert gas. Processing
                   of any other gas requires additional safety precautions typical to the application which are
                   not included herein.
                   Some precautions are general and cover several machine types and equipment; hence
                   some statements may not apply to your machine.
8                                                                                                 API093050
Instruction book
2 General description
Introduction
        The air dryers described in this book are heatless adsorption dryers, built to remove moisture
        from compressed air for industrial purposes.
        The standard version is intended to reach a pressure dew point of -40 ˚C (-40 ˚F). There is also a
        version available for a pressure dew point of -70˚C (-94 ˚F).
        All units are designed for indoor use, and altitude up to 2000 m.
Main parts
        An overview of the main parts of the dryer is given in below figures:
API093050                                                                                                9
                                                                                            Instruction book
2.2 Operation
General
      The construction of the air dryer is simple, reliable and easy to service. A dryer has basically two
      towers, containing the adsorption material or desiccant. This desiccant is a very porous grain
      material, able to adsorb large amounts of water vapour.
10                                                                                              API093050
Instruction book
API093050                                                                                                     11
                                                                                               Instruction book
      After a pre-set period, the function of the towers is reversed. The fully regenerated tower will now
      dry the air, while the desiccant in the other tower will be regenerated.
      By default, the regeneration timer will restart from the beginning of the cycle in case of a power
      failure during operation or in case the on/off switch was put in position 0.
      However, in case the input of remote control connector X3 (old denomination: P4 - freeze
      contact, see section Electric diagram) opens (by the freeze contact), the dryer will "freeze" the
      drying cycle: purge air flow stops, both solenoid valves are closed. When the contact, connected
      to connector X3 closes, the dryer will switch towers and will continue normal operation. This
      feature can prevent loss of compressed air (purge air) when the compressor is not continuously
      running loaded. On compressors with load/unload regulation, X3 can be connected to a voltage
      free contact of the compressor (contact open when the compressor runs unloaded). If no free
      contact is available, an additional voltage free contact should be installed on the load/unload
      contactor of the compressor to use this feature. See section Electrical connections for more
      details.
Flow diagrams
      Depending on the dryer size, the dryer can be composed of a single dryer module (flow diagram:
      see above), or of two or three dryer modules in parallel (see below):
12                                                                                                  API093050
Instruction book
API093050                                                                                 13
                                                                                             Instruction book
Control panel
      Note: The LED indication of the dew point (PDP) (LED’s 7 and 8) is only operational when the
      dryer is equipped with an electronic dew point indicator (available as option).
14                                                                                                API093050
Instruction book
3 Electrical diagram
         Reference   Explanation
         (1)         Customer's installation
         (a)         Maximum fuses with regard to circuit protection. Cable section may impose fuses of smaller
                     value
         (b)         Supply settings for X9
API093050                                                                                                  15
                                                                                              Instruction book
     Reference      Explanation
     (c)            Connection for remote control (X3): to NO contact of compressor
     (d)            Supply connection for 115 V and 230 V
     (f)            Time setting solenoid valves
     (g)            Connection PDP sensor
16                                                                                                API093050
Instruction book
4 Installation
Piping
                        Make sure that all pipes, filters, valves, etc. are clean and that they are installed correctly
                        with or without bypass system.
                        Make sure that the piping is installed stress-free. For more information concerning air nets,
                        cooling systems etc., refer to the compressor installation manual.
         To ensure correct operation of the dryer, it has to be fitted properly into the compressed air
         circuit. Depending from the fact if the remote control connector X3 is used or not (see section
         Operation), there are two possibilities:
API093050                                                                                                           17
                                                                                            Instruction book
X3 is not used
                 If the X3 connection is not used, the correct installation sequence is compressor - air
                 receiver - dryer.
       COMP         Compressor
       AR           Air receiver
       D            Dryer
       EIV          External inlet valve
                    To cut off the air supply towards the dryer
       EOV          External Outlet Valve
                    To cut off the air supply towards the air consumer
       BV           Bypass valves (not shown on the drawings)
                    Together with the external inlet valve and the external outlet valve, the bypass valves
                    allow the dryer and the filters to be serviced while non-dried air flows through the
                    bypass system.
       WSD          Water separator (optional)
                    To prevent free water from entering the dryer.
       DD           Compressed air prefilter DD: general purpose filtration, particle removal down to 1
                    micron, maximum oil carry-over 0.5 ppm
                    This filter is not included in the scope of supply, but recommended to provide extra
                    protection of the CD dryer and extend the lifetime of the PD filter cartridge.
18                                                                                               API093050
Instruction book
         PD                PD filter: high efficiency filter, particle removal down to 0.01 micron, maximum oil carry-
                           over 0.01 ppm
                           To remove remaining impurities.
         DDp               DDp filter: dust filter, particle removal down to 1 micron
                           To remove possible dust particles coming from the desiccant.
         QD                Filter with active carbon, capable of absorbing odour (not shown on the drawings). To
                           be installed downstream of the DDp filter if desired.
X3 is used
                        If the X3 connection is used, the correct installation sequence is compressor - dryer - air
                        receiver.
General recommendations
        Important: Keep the following in mind when installing the dryer:
            • Place the dryer at a location where the temperature never exceeds the limits, see section
              Limitations for operation.
            • The dryer does not require extra ventilation.
            • Fix the dryer as level as possible to the wall or to the floor. For certain models, a wall
              mounting kit is available as option - see spare parts book for part numbers. Make sure the
API093050                                                                                                          19
                                                                                                  Instruction book
         fixating screws are tightened firmly and that the wall or the floor is suitable for taking the
         weight of the dryer.
     •   Provide enough space around the dryer to install and service the filter elements. A minimum
         free space of 800 to 1000 mm is recommended.
         If the filters are mounted directly onto the dryer, the dryer should eventually be positioned
         higher to enable servicing of the filter elements.
     •   Use a DD filter and a PD filter at the inlet of the dryer. Use a DDp filter at the outlet of the
         dryer. Should oil vapour and odours are undesirable, a QD carbon filter can be installed
         downstream the DDp filter.
     •   If the compressor has no built-in water separator or if the dryer is not located near the
         compressor, a water separator (WSD) has to be installed before the dryer in order to prevent
         free water from entering the dryer, as free water can damage the desiccant. If the
         condensate contains oil, install an oil/water separator for draining of pure condensate water
         (consult your supplier).
     •   The drain hoses of the water separator and the filters must not dip into the sewer.
     •   It is recommended to install bypass pipes with ball valves over the filters in order to isolate
         the filters during service operations without disturbing the compressed air delivery.
     •   It is required to install pressure relief valves on the dryer when ball valves are installed at the
         inlet and the outlet of the dryer to isolate the dryer from the air net.
     •   If dryers are used in parallel make sure that all dryers can be bypassed through one of the
         other dryers, as shown in below figure:
                    Never overload the dryer as this will damage the desiccant. It may be recommended to
                    install the air dryer upstream of the air receiver to prevent overload (e.g. after extending the
                    dry air circuit). Consult Atlas Copco if in doubt.
20                                                                                                     API093050
Instruction book
5 Electrical connections
General
                                 The electrical wiring must comply with the local regulations. The air dryer must be
                                 earthed and protected by fuses against short-circuiting. Consult the electric
                                 diagram delivered with the dryer.
                                 Before switching on the main power supply, check the voltage requirements in the
                                 technical specifications or on the dryer’s data plate.
Timer card
API093050                                                                                                       21
                                                                                          Instruction book
           If you want to use the feature to “freeze” the regeneration cycle when the compressor runs
           unloaded, connect pin 1 and 2 of connector X3 with the potential free contact of the
           compressor (contact closed = freeze).
         • CAN-Bus connection
           The timer card can be interconnected in a LAN with other Elektronikon® controllers.
           Addressing and CAN protocol used are the same as for the Elektronikon regulators.
           Because the timer card has no programming features however, the exchanged information
           is pre-configured and cannot be redefined.
           Application: data communication between timer cards, MkIV Elektronikon regulators and
           service PC.
22                                                                                             API093050
Instruction book
                         Before switching on the main power supply, check the voltage requirements in the technical
                         specifications or on the dryer’s data plate.
API093050                                                                                                      23
                                                                                                      Instruction book
6 Operating instructions
Safety
Initial start-up
         To start up the dryer for the first time or after a long period of standstill, proceed as follows:
          1. If installed, open the bypass valves of the dryer.
          2. Close off the air supply from the compressor towards the dryer by closing the external inlet
             valve (if installed).
          3. If installed, close the outlet valve.
          4. Remove the silencers to prevent the silencers from getting clogged by the desiccant and
             wear a dust mask, safety glasses and ear protection. (This is only required at initial start-up
             or after the desiccant was replaced).
          5. Start the compressor and wait for pressure.
          6. Slowly open the inlet valve.
          7. Check the connections of the dryer for air leaks and remedy if necessary.
          8. Switch the dryer on by putting main switch S1 in position I.
          9. Let the dryer operate for several hours with the external outlet valve closed.
         10. In case the silencers were removed, refit the silencers.
         11. Gradually open the external outlet valve.
         12. If applicable, close the bypass valves of the dryer.
                            If the application allows air that is not completely dry, the valve towards the dry air
                            consumer may be opened even before the optimal Pressure Dew Point (PDP) is
                            reached. In this case however, it will take more time for the desiccant to dry the air
                            completely.
                            At initial start-up, and specially when the dryer is loaded from the beginning, it can take
                            a long time before the dew point is reached.
                            It is therefore recommended to operate the dryer for a number of days with the outlet
                            valve closed.
Normal start
         If the dryer has not been used for more than 3 months, refer to section Initial startup. In all other
         cases, proceed as follows:
          1. Cut off the air supply from the compressor towards the dryer by closing the external inlet
             valve.
          2. If installed, close the external outlet valve between the dryer and the dry air consumer.
          3. Start the compressor and slowly open the external inlet valve.
          4. Switch the dryer on by putting main switch S1 in position I.
          5. Gradually open the air outlet valve.
          6. If applicable, close the bypass valves of the dryer.
24                                                                                                         API093050
Instruction book
                           Close the external inlet valve in case the compressor needs to be restarted. The high
                           air speed in the startup phase of the compressor may damage the desiccant.
During operation
        At regular intervals, check the status of the LED’s on the control panel. If the warning/alarm LED
        is lit, consult the section Trouble shooting.
        If the dryer is equipped with a PDP temperature display, check the PDP temperature regularly. If
        the PDP temperature is too high, let the dryer regenerate by closing the outlet valve.
Stopping
        To stop the dryer, proceed as follows:
          1. If installed and if necessary, open the bypass valves of the dryer so that the application will
             still receive compressed air.
          2. Close the external inlet valve between the compressor and the dryer and the external outlet
             valve between the dryer and the dry air consumer.
          3. Let the dryer operate for a period without consumption, to depressurize the vessels.
          4. Switch off the dryer by putting main switch S1 to position 0.
                           If the dryer is stopped for a longer period, keep the external inlet and outlet valve
                           closed to avoid moisture from entering the dryer.
                           Under no circumstances must compressed air be allowed to flow through the dryer
                           when the electrical power is switched off. This will result in terminal failure of the
                           desiccant material, causing regeneration will no longer be possible.
API093050                                                                                                           25
                                                                                               Instruction book
7 Maintenance
7.1 Maintenance
                            Filters and valves installed between the compressor, the dryer and the air consumer
                            may need other maintenance activities than those mentioned below (e.g. draining the
                            filters and replacing the filter elements). Refer to the appropriate manual for more
                            information.
26                                                                                                  API093050
Instruction book
        Used filters or any other used material (e.g. desiccant, lubricants, cleaning rags, machine parts,
        etc.) must be disposed of in an environmentally friendly and safe manner, and in line with the
        local recommendations and environmental legislation.
API093050                                                                                                27
                                                                                           Instruction book
     Electronic components are subject to the EU Directive 2012/19/EC for Waste Electrical and
     Electronic Equipment (WEEE). As such, these parts must not be disposed of at a municipal
     waste collection point. Refer to local regulations for directions on how to dispose of this product in
     an environmental friendly manner.
28                                                                                              API093050
Instruction book
8 Problem solving
Overview
API093050                                                                                                              29
                                                                       Instruction book
9 Technical data
30                                                                          API093050
Instruction book
Instructions
                       Description
         1             The dryers can contain pressurized air. This can be potentially dangerous if the
                       equipment is misused.
         2             The towers of the dryer consist of an extruded profile, which must only be used as a
                       compressed air vessel and must be operated within the limits specified. See section
                       Pressure Equipment Directives, table A.
         3             No alterations must be made to the vessels by welding, drilling or other mechanical
                       methods without the written permission of the manufacturer.
         4             The design pressure and temperature of this pressure bearing part must be clearly
                       indicated on the data label.
         5             If installed, the safety valve must correspond with pressure surges of 1.1 times the
                       maximum allowable operating pressure. This should guarantee that the pressure will not
                       permanently exceed the maximum allowable operating pressure of the vessel.
         6             Original bolts have to be used after opening for inspection. The maximum torque has to
                       be taken into consideration (see table below).
API093050                                                                                                     31
                                                                                          Instruction book
Guidelines
      On the Declaration of Conformity / Declaration by the Manufacturer, the harmonized and/or other
      standards that have been used for the design are shown and/or referred to.
      The Declaration of Conformity / Declaration by the Manufacturer is part of the documentation that
      is supplied with this air dryer.
      Local legal requirements and/or use outside the limits and/or conditions as specified by Atlas
      Copco may require other inspection periods as mentioned below.
32                                                                                            API093050
Instruction book
         Dryer      Tube drawing    Design        Design       PED        Tube wall    Tube         Tube
         type       p.n.            pressure      tem-         category   thickness    diameter     internal
                                    bar(e)        perature                mm           mm           volume
                                                  °C                                                l
         CD 25+,                                  -10 to +80   I          6            150          15.7
         CD 30+,
         CD 60+
         CD 35+,    1624 0940 00    16            -10 to +80   I          6            150          20.0
         CD 70+
         CD 50+, 1624 0974 00       16            -10 to +80   I          6            150          26.5
         CD 80+,
         CD 100+,
         CD 145+
API093050                                                                                                   33
                                                                                       Instruction book
13 Declaration of conformity
34                                                                                          API093050
                                                                      Atlas Copco Airpower NV. All rights reserved. Designs and specifications are subject to change without notice or obligation.
COMMITED TO SUSTAINABLE PRODUCTIVITY
We stand by our responsibilities towards our customers, towards the
environment and the people around us. We make performance stand
the test of time. This is what we call — Sustainable Productivity.
www.atlascopco.com