TECHNICAL DATA

DIESEL GENERATING SET

50HZ

VG60W
Standard Features • Top lifting, Forklift bottom hole design, easy to
• Compact structure with high-strength chassis; transport;
• Easy operation and maintenance, Low cost; • Industrial muffler;
• Excellent performance damping system; • Noise reduction structure, Low noise;
• Compliance with international electrical safety standards • Convenient power output interface;

of electrical system; • Deepsea Module Controller

• 8 hours base tank; • Customized design for user

• High-performance maintenance-free batteries with


isolation switch
• 50℃Radiator;

Dimension and Weight (Approximate)


Generating set model Open Type Silent Type
Length (L) (mm) N/A 2450
Width (W) (mm) N/A 950
Height (H) (mm) N/A 1230
Dry weight (kg) N/A 1185
Tank Capacity ( L ) N/A 80
MODEL VG60W
ENGINE SPECIFICATION
Engine Brand / Model WEIFANG / N4105ZDS
Prime Power 60 kVA/ 48 kW
Rated Speed 1500 Rpm
Number of Cylinder - Arrangement 4 – Vertical in Line
Cycle 4 Stroke
Rated Current (A) 101.16
Governor Mechanical
Bore x Stroke 105 x 125 mm
Displacement 4.33 L
Cooling System Water cooling
Oil Capacity 11.2 L (Min)
Coolant Capacity 12 L Engine Only
Fuel Consumption @100% Load 12 Ltr/h
Starter Motor 12VDC
Alternator 12VDC

ALTERNATOR SPECIFICATION
Alternator /Model WINSTON
Prime Power 60 kVA
Phase 3 (Three)
Rated Voltage 380/220 V ; 400/230V
Frequency 50 Hz
Exciter type Self excitation, Brushless
Power factor 0.8
Voltage adjust range ≥5%
Voltage regulation ± 1.0 %
Insulation grade H
Protection grade IP23
Winding Stator Double Layer Lap
Winding Pitch Two Third
Winding Leads 12
Waveform Distortion No Load < 1.5% Non Distorting Balanced Linear Load
< 5.0%
Maximum Overspeed 2250 rev/min
Optional
Optional Alternator brand N/A
Optional Alternator model N/A
Rated output prime power N/A
Control System
Deepsea – DSE4620
All V-GEN Gensets have a control cabinet (the Deepsea control module DSE4620 as standard mounted on isolated
support.

The DSE4820 Auto Mains (Utility) Failure Control Module are suitable for a wide variety of single gen-set applications.

Whilst maintaining functions included within higher end controllers, such as generator or load power monitoring, the
DSE46xx range of especially compact controllers provide the user with the ultimate size to feature ratio.

Monitoring engine speed, oil pressure, coolant temperature, frequency, voltage, current, power and fuel level, the
modules will give comprehensive engine and alternator protection. This will be indicated on the largest back-lit LCD
icon display in its class via an array of warning, electrical trip and shutdown alarms.

KEY BENEFIT AND FEATURE

 Auto Start and AMF mode in one module (DSE4620


only)
 J1939-75 support and CAN alarm ignore function
 Alternator frequency & CAN speed sensing in one
variant
 Largest back-lit icon display in its class (configurable
as text display)
 Heated display option
 Real time clock provides accurate event logging
 Fully configurable via the fascia or PC using USB
communication
 Extremely efficient power save mode
 1 alternative configuration
 3 phase generator sensing
 Comprehensive warning, electrical trip or shutdown
 3 phase mains (utility) sensing (DSE4620 only)
protection upon fault condition
 Compatible with 600 V ph to ph nominal systems
 LCD alarm indication
 Generator/load power monitoring (kW, kV A, kV Ar,
 Coolant temperature pre-alarm
pf)
 Event log (50)
 Accumulated power monitoring (kW h, kVA h, kVAr h)
 Fuel solenoid pulling circuit
 Generator overload protection (kW)
 On-screen line diagram on/off functionality
 Generator/load current monitoring and protection
 Configurable CAN instrumentation (10)
 Fuel and start outputs (configurable when using CAN)
 Water in fuel digital input
 4 configurable DC outputs
 Tank bund alarm digital input
 5 V output
 Generator at rest output
 Configurable fuel & crank outputs
 ECU periodic wake-up for information retrieval
 3 configurable analogue/digital inputs
 Back-light power-save mode
 4 configurable digital inputs
 Adjustable delay crank timer
 Configurable staged loading outputs
 Pre/post heat functionality
 3 engine maintenance alarms
 Overload protection
 Engine speed protection
 Mains/generator A/C system selection
 Engine hours counter
 Output timer for external audible alarm
 Engine pre-heat
 Accommodates a wide range of senders and
 Engine run-time scheduler
temperatures
 Engine idle control for starting & stopping
 Tier 4 engine instrumentation screens
 Battery voltage monitoring
 Start on low battery voltage
 Configurable remote start input
Contact Us
DISTRIBUTED BY:


C Manufactured by VGEN, All right reserved
VGEN by Rajawali Diesel reserves the right to make changes in model, technical specification, color, configuration and
accessories without prior notice. Please contact the salesman before ordering.