SM
ANALYTICAL PROCEDURE                                                            Ammonia
                                                                                        Test Kit C0041
                                                                                                              AP-85
SPECIFICATIONS
Method: Color Comparison (Ampoule)
Range: Low Range — 0.1 to 1 ppm as NH3
       High Range —1 to 10 ppm as NH3
Testing Time: 5 minutes
DESCRIPTION
The Ampoulemetric Ammonia Test Kit, C0041, can
be used to analyze steam condensate and samples
from most rivers, lakes and streams. Simply insert a
reagent ampoule into the sample and snap off the
tip. The exact amount of sample is automatically       Ampoulemetric Ammonia Test Kit
extracted.
The analysis is completed by comparing the             INTERFERENCES
ampoule to the color standards.                        Various aromatic and aliphatic amines will react
                                                       with this reagent.
ORDERING INFORMATION
Order as Test Kit C0041. Order all replacement         SAFETY PRECAUTIONS
parts and reagents by their part numbers. To be        Refer to Material Safety Data Sheet (MSDS) for
sure this product is compatible with your treatment    specific reagent personal safety and disposal infor-
program, contact your local Nalco representative.      mation.
Items marked with an “*” are included with the kit
or set.
                                                       SUPPORT
To place your order, simply call our Order Entry
Department at 1-800-962-8313.                          If you have any questions regarding this procedure,
                                                       please contact your Nalco representative or the
                                                       Applied Services Help Desk at 1-800-323-8483.
REPLACEMENT PARTS AND REAGENTS
Required Parts and Reagents
                                                       SAMPLING
Description                     Size       Part No.
                                                       1. Samples that are strongly acidic or buffered may
Ammonia stabilizing (6/pkg)     1/2 oz.    P0317*         require neutralization prior to analysis.
Description                                Part No.    2. Colored or turbid samples will cause error by
Refill ampoules (30/pkg)                   P0316*         obscuring the color of the solution in the
                                                          ampoule.
AMMONIA TEST KIT PROCEDURE — Low Range: 0.1 to 1 ppm
                                                                               25                               25
                                                                               20                               20
                                                                               15                               15
                  25                               25
                                                                               10                               10
                  20                               20
                                                                                5                               5
                  15                               15
  1                                2                               3                              4
                  10                               10
                  5                                5
Fill the sample cup to the 25-   Add 1 to 2 drops of A-1500      Place the tapered tip of the   Snap the tip by squeezing
mL mark with sample.             (P0317) stabilizing solution.   ampoule into one of the four   the ampoule toward the side
                                                                 depressions in the bottom of   of the cup. The sample will
                                                                 the sample cup.                permeate the ampoule and
                                                                                                blend with the reagent.
                                                                                                 Note: A small gas bubble
                                                                                                 will remain in the ampoule
                                                                                                 to aid in the mixing
                                                                                                 process.
                                                                                    T YP E
                                                                                    A N-1
  5                               6                               7                               8
Remove the filled ampoule        Wipe the exterior of the        Place the ampoule in the       While holding the
from the cup and mix by          ampoule dry and wait one        cylindrical comparator, flat   comparator in a horizontal
inverting several times.         minute.                         end downward. Direct the       position, rotate it until a color
                                                                 top of the cylinder toward a   match is obtained.
                                                                 light source while viewing
                                                                 the bottom.                     Note: Test results are
                                                                                                 expressed in ppm (mg/L)
                                                                                                 as ammonia-nitrogen,
                                                                                                 NH3-N. To convert to ppm
                                                                                                 (mg/L) ammonia as NH3,
                                                                                                 multiply test results by 1.2.
AMMONIA TEST KIT PROCEDURE — High Range: 1 to 10 ppm
                                                                                          25                                                           25
                                                                                          20                                                           20
                                                                                          15                                                           15
                  25                           25
                                                                                          10                                                           10
                  20                           20
                                                                                           5                                                            5
                  15                           15
  1                            2                               3                                                            4
                  10                           10
                  5                             5
Fill the sample cup to the   Add 1 to 2 drops of A-1500      Place the tapered tip of the                                 Snap the tip by squeezing
25-mL mark with sample.      (P0317) stabilizing solution.   ampoule into one of the four                                 the ampoule toward the side
                                                             depressions in the bottom of                                 of the cup. The sample will
                                                             the sample cup.                                              permeate the ampoule and
                                                                                                                          blend with the reagent.
                                                                                                                          Note: A small gas bubble
                                                                                                                          will remain in the ampoule
                                                                                                                          to aid in the mixing
                                                                                                                          process.
                                                                    1   2                                                        1   2
                                                                              3     4                                                      3     4
                                                                            Dissolved       5       6                                    Dissolved       5       6
                                                                                        Oxygen,           8     10                                   Oxygen,           8     10
                                                                                                  PPM (mg            12                                        PPM (mg            12
                                                                                                          /L)                                                          /L)
  5                           6                                7                                                            8
Remove the filled ampoule    Wipe the exterior of the        Using the flat comparator,                                   Hold the comparator in a
from the cup and mix by      ampoule dry and wait one        place the ampoule between                                    horizontal position and
inverting several times.     minute.                         the color standards for                                      determine a color match.
                                                             viewing.
                                                                                                                          Note: Test results are
                                                                                                                          expressed in ppm (mg/L)
                                                                                                                          as ammonia-nitrogen,
                                                                                                                          NH3-N. To convert to ppm
                                                                                                                          (mg/L) ammonia as NH3,
                                                                                                                          multiply test results by 1.2.
                                      ENHANCING CUSTOMER
                               SATISFACTION THROUGH QUALITY
                                Nalco Chemical Company’s mission is to
                                enhance the profitability of our customer’s
                                business by providing products and services
                                that add value to their operations and
                                enhance their return on investment.
                                We are committed to a quality management
                                philosophy that strives for continuous
                                improvement. Every employee is expected
                                to do his or her part to ensure our
                                products and services lead to
                                increased customer
                                satisfaction.
                                     NALCO APPLIED SERVICES
           NALCO CHEMICAL COMPANY • ONE NALCO CENTER • NAPERVILLE, ILLINOIS 60563-1198 • USA
NALCO EUROPE B.V. • IR.G.TJALMAWEG 1 • 2342 BV OEGSTGEEST • P.O. BOX 627 • 2300 AP LEIDEN • THE NETHERLANDS
                   NALCO PACIFIC PTE, LTD • 21 GUL LANE • JURONG TOWN • SINGAPORE 2262
                              NALCO LATIN AMERICA • SÃO PAULO • SP • BRAZIL
                      Registered Trademarks of Nalco Chemical Company ©1995 Nalco Chemical Company
                                         All Rights Reserved Printed in U.S.A. 11-95