100% found this document useful (1 vote)
882 views15 pages

Mini-Link CLI

Uploaded by

DOKO
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
100% found this document useful (1 vote)
882 views15 pages

Mini-Link CLI

Uploaded by

DOKO
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
You are on page 1/ 15
ERICSSON 2 CLI JOB AID FOR TRAFFIC NODE 1(15) Alexandru Aldea ea Tena oo Te EES Error! 02/08/2010 __Error!_| Error! Unknown CLI procedures for Traffic Node’s 1. Connecting to a Traffic Node with Telnet 1.4 Finding IP address of the Traffic node 4-2 Connecting with a Traffic Node with Telnet. 2. Procedures 2.4 Show E1 tralls / connections 2.2 Show position of the units in the rack 2.3 Show boards information (Serial ,Type Software version) 2.4 Worm restart on Traffic Node 2.5 How to check the temperature 2.6 How to place loops E1 trails 2.7 How to check the configuration of a port : 2.8 How to make a TDM E1 connection between two units (MMU/NPU) 2.9 Crash logs / syslog 2.10 Alarms on ports 3. Shortcomings Regards to lon Laurentui Dorin s ERICSSON & CLI JOB AID FOR TRAFFIC NODE 2(15) PRT IES TIBET OTT Ti Alexandru Aldea ea Tosser a Te aT Error! 02/08/2010 __Error!_| Error! Unknown 41. Connecting to a Traffic Node with Telnet 1.1 Finding IP address of the Traffic nod - From Visio file (fig.1) F0870 1211F7 72.1 1+1 MSP. ME1061 8E1 Fig. 1 - From SOM , by click on Network Data List (fig 2) , we can obtain the IP address from the new window wich it will appear in the right workspace (fig. 3) ERICSSON 3 CLI JOB AID FOR TRAFFIC NODE 3(15) [eRe TY Ti Alexandru Aldea 7 Tena Dai ay ¥ Error! 02/08/2010 __Error!_| Error! Unknown. @ dp cluster 14 aly CLUSTER 15 6 aly cLusTER 17 Sd one-cu72 B one-cii7-24 & een Zoom In... So ONECL a petwork Data List @ dy one_cu Locate SOONECLIY gy NE-CL17-1) ~ 7 i Remove... — ‘Communication Events Commands — Configuration Comm aut Zoomin completed | pomain ‘Service Bese, Mae ERICSSON 2 CLI JOB AID FOR TRAFFIC NODE 415) Alexandru Aldea ea Toa oo Te EES Error! 02/08/2010 __Error!_| Error! Unknown 1.2 Connecting with a Traffic Node with Telnet . - Open command prompt (Start>cmd) - For testing if the site is reachable we can try to “ping” it - To connect we use Telente = >telnet_ - Password used : ericsson File Edit Communication Configuratio a Tall - y Cheer eben) Fig.4 Ecinstreoser - Now we are in Exec Mode , CLI commands for the TN are sorted into classes (Fig. 5), P 4 Sse Hy cee Eh, Pitot cantare, Gand al — oe Re Fig. 5 Interface Configuration Protocol sub ayer Configuration Route map Configuration Router Configuration ERICSSON 2 CLI JOB AID FOR TRAFFIC NODE 5 (15) Alexandru Aldea ea Tena oo Te EES Error! 02/08/2010 __Error!_| Error! Unknown - To enable Privileged Exec Mode we enter NE-CL17-2-1> enable Password : ericsson NE-CL17-2-1# NOTE: Privileged mode offer the capability to change configuration on TN , be careful when using “configure” command. (please don’t try commands witch are not cover by this paper ) - For more power on configuration and debug on TN we can enable hidden command by entering : NE-CL17-2-1# cliunlock NOTE: Hidden command offer more power on configuring and debug , Use it with caution (please don’t try commands witch are not cover by this paper ) 2. Procedures 2.1 Show E1 trails / connections: (privilege+cliuntock}# show connections is optional , i We can see in the next figure the correlation between Mini is not inserted it will display all connection on the TN. craft and CLI. ERICSSON 2 CLI JOB AID FOR TRAFFIC NODE (15) Alexandru Aldea Tae Tora oo Te am Error! 02/08/2010 _Error!_| Error! Unknown NE-CL17-2-1 Traffic Routing cosas | se | oa sername Fig.6 2.2 Show position of the units in the rack : NE-CL17-2-1# show subrack usually is “1” , in the next figure we can see the correlation between Minilink craft and CLI. ERICSSON 2 CLI JOB AID FOR TRAFFIC NODE 715) Alexandru Aldea Tae Toa oo Te am Error! 02/08/2010 __Error!_| Error! Unknown 2.3 Show boards information (Serial ,Type Software version) NE-CL17-2-1#show board Note: In the next figure we displayed info regarding the MMU2 C (1/2) , we can se the correlation with the minilink craft Fig. 8 For more board info we can use the following arguments : NE-CL17-2-1#show board 1 / 2 config - check if it is in service and if it is enable NE-CL17-2-1#show board 1/2 status - check if board is in repair mode. 2.4 Worm restart on Traffic Node. NE-CL17-2-1#reload 2.5 How to check the temperature NE-CL17-2-4#show temp Note: it will show the current temperature of each board, and the high / exceed values . ERICSSON 2 CLI JOB AID FOR TRAFFIC NODE 8 (15) Alexandru Aldea est Tear a Tra ae Error! 2108/2010 __Error!_| Error! Unknown 2.6 How to place loops E1 trails — et ‘The following loops are shown in Figure a, 5 1 Line loop wf ~~) ™ 2 Connection loop - 92 3 IF loop iT Sy | 4 RF loot =) me | Ss extoop Fq GE |*) | 6 Local loop 7 Physical loop Fig 9 Enter configuration mode : NE-CL17 -2-1#config Select the e1 controller (use show trail to identify where to place the loop and what tipe of loop (line loop , or local loop , usually we use local loop): Enter controller configuration mode: NE-CL17-2-4#controller e1 For MMU wich uses an E2 (example) we use the following syntax: NE-CL17-2-1#controller 02 “Rack/Slot/Port Port.number” Leer rest eae aeetiery eC atest s ERICSSON & CLI JOB AID FOR TRAFFIC NODE 9(15) Alexandru Aldea ea Tena oo Te EES Error! 02/08/2010 __Error!_| Error! Unknown When you are on controller configuration mode we can place tha localline loop = NE-CL17-2-1#loopback local/line For removing the loop use NE-CL17-2-1# no loopback local/line Exiting configuration mode or controller configuration mode is made by entering “exit” in CLI. 2.7 How to check the configuration of a port : NE-CL17-2-1#show configuration NOTE: when ports configured with next pathern 1/1/4A (usually on NPU) we can use “1/1/0” 2 evave ijijios = e1iyijsa — EL 1/1/48 Z evanac = en aio GB vain => User Output 1/1/4 Fig. 11 Note : we can use this command to determine if there is any loops on our E1 trail , also different configuration option , if ais-alarm si active , interface name , correlation between physical position of port and name of the port, if the connection is active . ERICSSON 2 Alexandru Aldea CLI JOB AID FOR TRAFFIC NODE 10(15) 02/08/2010 Error! __| Error! Unknown Secrets ete ee i Tanta tree) framing-possible-88 timing poss ible=20 introns’ hide = epee crater am rreeestni rovisrese ier sre) eae st iret hice hee eee hort disabled: last bit error enters trepsmnr eZ o2u ieee ae orens heen Fig. 12 ey 2.8 How to make a TDM E1 connection between two units (MMU/NPU) There are 2 methods to make a connection between : - easy way , by declaring a E1 connection between 2 units (NPU/MMU) with the following procedure: a. enter configuration mode b. enter : ERICSSON 2 : CLI JOB AID FOR TRAFFIC NODE 12(15) Alexandru Aldea Tae Tora oo Te am Error! 02/08/2010 __Error!_| Error! Unknown 4157;0-4158;0-4354;0-4355;0-4550;0-4551 ;0-4746;0-4747;0-4942;0-4943;0- 5139;0-5140;0-5335;0-5336;0-5531;0-5532;0-5728;0-5729;0-5924;0-5925 6120;0-6121;0-6317;0-6318; Note :this method is used only in making the configuration file. 2.9 Crash logs / syslog For finding out last actions made on the TN we can use the following command : NE-CL17-2-1#show x crashlog Note : it will display the entire crashlog on the screen starting with the past till last changes made on equipment. Crash log example : EES ST ST Bee ee ee eer eT Ate Teer Re eoe ee eee Pore manere et tt eee eRe TEN Pe eee Pe eet ee ee Cra PO eee se eee ee Coe ee Pee ee et eee ee ere CLERC ee) We can see that simulation of cold restart on NPU was tested. For viewing the syslog we can use the next command : NE-CL17-2-4#show x tail-syslog ERICSSON 2 Alexandru Aldea CLI JOB AID FOR TRAFFIC NODE 13.(15) 2108/2010 __Error! Error! Error! Unknown 2.10 Alarms on phy: al ports. To display alarms on physical ports we need the following command. NE-CL17-2-1# show pm_int_port phy In the next figure we can see an view with no alarms on the port cee eee CoCr e ported clot: 1, port: @ ar) mat) ee es costes See ee eet Ea Tea) jer layer SES decremented: @ eee ree A eae ee Seat a Se (eanee eT ee ee) canes yt Me eee ne eee ete! Pore Cae tte eo) Pa ry fete D yee teea} Pees eoraeet sty ore upression: @. Cee Ree ee Second Error Set alarm on the E1 port. ERICSSON 2 CLI JOB AID FOR TRAFFIC NODE 14.(15) Alexandru Aldea ea Tena oo Te EES Error! 02/08/2010 __Error!_| Error! Unknown 3. Shortcomings CLI offers configuration and debugging options only for NPU and MMU , between E1 trails , configuring management , routing , routing protocols witch will be use . From Till now I didn’t find out any method to obtain info regarding the radio part (signal strength , alarms on RAU , IF ,RF only Rx loop by using line loop on MMU E1 port). The only info regarding the Radio link we can obtain from the tables declared for the radio link application (rl ) but | couldn't decipher it. ERICSSON 2 CLI JOB AID FOR TRAFFIC NODE 16.(15) PRT IES TIBET OTT Alexandru Aldea Tosser Error! a 02/08/2010 Error! Error! Unknown

You might also like