0% found this document useful (0 votes)
935 views1 page

IMO Symbols

This document provides a fire control plan detailing the fire safety equipment onboard a vessel. It lists the types and quantities of portable fire extinguishers, fixed firefighting systems, fire doors, dampers, alarms, detectors and other fire safety devices. Location codes are given for each item. The plan aims to ensure all necessary fire equipment is in place and properly maintained to combat and contain fires.

Uploaded by

Wan Tak Si
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
935 views1 page

IMO Symbols

This document provides a fire control plan detailing the fire safety equipment onboard a vessel. It lists the types and quantities of portable fire extinguishers, fixed firefighting systems, fire doors, dampers, alarms, detectors and other fire safety devices. Location codes are given for each item. The plan aims to ensure all necessary fire equipment is in place and properly maintained to combat and contain fires.

Uploaded by

Wan Tak Si
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

IMO-SIGNS FOR FIRE CONTROL PLAN ...

be prepared

FIRE FIGHTING EQUIPMENT FIRE CLASS VENTILATION ALARM DEVICES FIRE ALARM /DETECTORS

W W P P F H A M C
CO2
6L 9L 6 12 6L 6 6

192261 - W 6 192261 - W 9 192261 - P 6 192261 - P 12 192261 - F 6 192261 -Co2 6 192261 - H 6 192314 192287 192288 192311A 192311M 192311C 192202 Manually 192204 192316 192316 192317
Fire ext. Fire ext. Fire Ext. Fire Ext. Fire Ext. Fire Ext. Fire Ext. Main vertical zone A class division B class division Ventilation Ventilation Ventilation Push button/switch operated call Bell fire alarm Space or group Space or group Space
remote control remote control remote control for general alarm point of spaces of spaces monitored
FIRE DOORS or shut-off or shut-off or shut-off monitored by monitored by by gas
heat detector(s) heat detector(s) detector(s)
FIRE DAMPERS CO
S2 CO
H2
WT SWT WT SWT
W P F CO2 H
50 L 50 L 50 L 50 L 50 L F FD
A
A M
M C
C
192203 192210 192223
192305WT 192305 192305SWT 192309-WT 192309 192309SWT Horn fire alarm Sprinkler horn Halon horn
192267 - W 50 192267 - P 50 192267 - F 50 192267 - Co2 50 192267 - H 50 Refill for fire 192236 - F B class self B class self B class self
A class self A class self A class self 192315 192206
Wheeled fire Wheeled fire Wheeled fire Wheeled fire Wheeled fire extinguisher Foam nozzle closing sliding closingsliding closing sliding
closing sliding closing sliding closing sliding 192289A 192289M 192289C Space or group Space protected by
extinguisher extinguisher extinguisher extinguisher extinguisher fire door fire door fire door
fire door fire door fire door Fire damper Fire damper Fire damper of spaces automatic fire alarm
CO 2 CO
I 2 FM-200 monitored by
REMOTE CONTROLS smoke
WT
WT SWT
SWT WT
WT SWT
SWT
detector(s)
W P F
W P F A M C 192223 192223 190000
Halon horn Halon horn FM-200 alarm
192303-WT 192303 192303-SWT 192307 - WT 192307 192307 - SWT
192245 - W 192245 - P 192245 - F 192231 - W 192231 - P 192231 - F A class sliding A class sliding A class sliding B class fire door B class fire door B class fire door
Fire hose and Fire hose and Fire hose and Monitor Monitor Monitor fire door fire door fire door -A -M -C
nozzle nozzle nozzle Remote control for Remote control for Remote control for
fire damper(s) fire damper(s) fire damper(s)
WT
WT SWT
SWT WT
WT SWT
SWT
CLOSING DEVICE FOR VENT.
190000 Light signal PA -speaker for
A M
A M
A
C Ships bell column alarms and
192308-WT 192308 192308-SWT 192308 - WT 192308 192308 - SWT A M C (include fire information
192294 A class fire door A class fire door A class fire door B class fire door B class fire door B class fire door alarmhorn el.
Portable foam self closing self closing self closing self closing self closing self closing Type,dead
applicator unit or man alarm)
relevant spare 192310 - A 192310 - M 192310 - C
tank(s) WT
WT SWT
SWT WT
WT SWT Closing device for Closing device for Closing device for
ventilation ventilation ventilation
HYDRANTS inlet or outlet inlet or outlet inlet or outlet
REMOTE CONTROLS
W F W P F S 192306-WT 192306 192306-SWT 192306 - WT 192306 192306-SWT FIRE PUMPS MISC
A class fire door A class fire door A class fire door B class fire door B class fire door B class fire door
A M C

192244 - W
Fire hydrant
192244 - F
Fire hydrant
192211 - W
Fire main
section valve
192211 - P
Powder section
valve
192211 - F
Foam section
valve
192211 - S
Sprinkler section
valve
192247
International
shore
REMOTE CONTROLS
-A -M -C
192248
IG G
Remote control Remote control 192248
connection WT FD Remote control Emergency fire 192256 192296 Emergency Emergency
for closing for closing Fire pump(s)
for closing Bilge pump Inert gas source of source of
BATTERIES device(s) for device(s) for device(s) for
pump
installation electrical power electrical power
ventilation inlet ventilation inlet ventilation inlet (generator) (battery)
and outlet and outlet and outlet
W P F CO2 N H 192290 192290
Remote control Remote control
for watertight for fire doors A - Accomodation and service / M - Machinery / C - Cargo
doors
192257
192212 - W 92212 - P 92212 - F 92212 - Co2 92212 - N 92212 - H WT - Watertight door / SWT - Semi Watertight door / FD - Fire door Emergency
Fixed fire- Fixed fire- Fixed fire- Fixed fire- Fixed fire- Fixed fire- bilge pump 192301 Air compressor Control panel for
extinguishing extinguishing extinguishing extinguishing extinguishing extinguishing REMOTE CONTROLS Emergency for breathing fire detection
battery battery battery battery battery battery switchboard devices and alarm
system
FIRE LOCKERS EQUIP.
W P F CO2 N H REMOTE CONTROLS Fire

1
Plan

192228 - W
Fixed fire-
192228 - P
Fixed fire-
192228 - F
Fixed fire-
192228 - Co2
Fixed fire-
192228 - N
Fixed fire-
192228 - H
Fixed fire-
ME
FL FE 192248
Remote control
for fire pump(s)
192248
Remote control
for emergency
Remote control
for bilge
pump(s)
192293
Control station
192319
Emergency
192201
Fire protection
extinguishing extinguishing extinguishing 2
extinguishing extinguishing extinguishing fire pump or fire telephone appliances or
190001 Fire locker 192280 192320 pump supplied
bottle, placed in bottle, placed in bottle, placed in bottle, placed in bottle, placed in bottle, placed in Nødstop hoved Fuel pump(s) Lube oil pump(s) Remote control Remote control Remote control station Structural fire
Number to use Locker with Fire axe by the emergency
protected area protected area protected area protected area protected area protected area motor remote shut-off remote shut-off for fuel oil for lube oil for fire pump protection plan
with other symb. fireman`s outfit source of power
valves valves valve(s)

W P F CO2 N H

Remote control Oil Pollution


192234 - W 192234 - P 192234 - F 192234 - Co2 192234 - N 192234 - H 192297 192281 192283 Breathing for emergency equipment
Fixed fire- Fixed fire- Fixed fire- Fixed fire- Fixed fire- Fixed fire- High expansion 192290 Locker with Locker with apparatus bilge pump
extinguishing extinguishing extinguishing extinguishing extinguishing extinguishing foam supply Remote additional additional
installation installation installation installation installation installation trunk (outlet) controlled breathing protective
skylights apparatus clothing
REMOTE CONTROLS
W P F Co2 N H

192217 - W 192217 - P 192217 - F 192217 - Co2 192217 - N 192217 - H


Remote release Remote release Remote release Remote release Remote release Remote release
station station station

IMO-SIGNS FOR SAFETY PLAN


station station station

SPACE PROTECTED BY
191000 191001 191002 191003 191004
RECOMMENDED SYMBOLS INDICATING THE LOCATION OF EMERGENCY EQUIPMENT 191005 191006 191007 191008 191009
W D P F CO2 H AND MUSTER AND EMBARKATION STATIONS

192215 - W 192217 - D 192217 - P 192217 - F 192217 - Co2 192217 - H


Space or group Space or group Space or group Space or group Space or group Space or group
of spaces
protected by fire-
of spaces
protected by fire-
of spaces
protected by fire-
of spaces
protected by fire-
of spaces MISC
protected by fire-
of spaces
protected by fire-
extinguishing extinguishing extinguishing extinguishing extinguishing extinguishing 191011 191012 191301 191302 191303 191304 191324 191323 191307 191308 191309 191310 191311 191305 191306 191322 191316 191317 191318 191320
system system system system system system Lifeboat Rescue boat Liferaft Davit launcher Embarkation Evacuation Immersion Life buoy Life buoy Life buoy Life buoy with Lifejacket Child`s lifejacket Muster station Survival craft Epirb Radar Ships rocket
liferaft ladder slide suit with line with light light and smoke portable radio transponder parachute flares

W D WM F CO2 W
7

192270 192237 - W 192237 - D 192237 - WM 192237 - F 192237 - Co2 192259 - W


Water spray Water fog Space protected Space protected Space protected Space protected Water fog 191321 191319 190000 Emergency exit First aid kit Stretcher Signal lamp Fire proof Helicopter Helicopter Water tight Stairs Megaphone Emergency 192286
Hospital 192285
system valves apllicator by Drenching by Water mist by foam by Co2 valve Line throwing Survival craft Life buoy with 24V line landing area pickup area door escape breathing Primary escape Secondary
applince pyrotech. light and line device (EEBD) means
route
Distress of escape
signals

P- Powder / W - Water / F - Foam / Co2 - Carbon dioxide / N - Nitrogen / H - Halon (Gas other than Co2) / D - Drenching / WM - Water mist

INTERNATIONAL MARITIME ORGANIZATION


© 2004 - Copyright SiS Norge AS
Resolution A.952(23) - MSC/Circ 1050
SiS Norge AS - Åregjerdet 9A, 6018 Ålesund, Norge GRAPHICAL SYMBOLS FOR FIRE CONTROL PLANS
Telefon +47 70 17 29 00 - Telefax +47 70 17 29 01 Adopted by the IMO Assembly on 19 October 1989