0% found this document useful (0 votes)
53 views3 pages

Yuken MP-03

This document provides specifications for Pilot Operated Check Modular Valves. It describes the model numbers, designations, standards, and typical performance characteristics. The model numbers indicate the series, cracking pressure, design number, and design standard. Graphs show pressure drop and minimum pilot pressure characteristics for different flow rates and supply pressures.

Uploaded by

ari sukanti
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
53 views3 pages

Yuken MP-03

This document provides specifications for Pilot Operated Check Modular Valves. It describes the model numbers, designations, standards, and typical performance characteristics. The model numbers indicate the series, cracking pressure, design number, and design standard. Graphs show pressure drop and minimum pilot pressure characteristics for different flow rates and supply pressures.

Uploaded by

ari sukanti
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Pilot Operated Check Modular Valves

Specifications
Max. Operating
Max. Flow
Model Numbers Pressure
L/min (U.S.GPM)
MPa (PSI)
Standard MP*-03-*-20
Low Pilot Pressure 25 (3630) 70 (18.5)
MP*-03-*-2001
Control Type

Model Number Designation


F- MPA -03 -2 -20 *
Cracking
Valve Pressure Design Design
Special Seals Series Number
Size Number Standard
MPa (PSI)
MPA : Pilot Operated 20
F: Check Valve (Standard)
Special Seals for A-Line
for Phosphate MPB : Pilot Operated 2 : 0.2 (29) 2001
Ester Type Check Valve 03 (Low Pilot Refer to
Fluids for B-Line 4 : 0.4 (58) Pressure
(Omit if not MPW : Pilot Operated Control
required) Check Valve Type)
for A&B-Lines

Design Standards: None ........... Japanese Standard "JIS", European Design Standard and
N. American Design Standard

Graphic Detailed Graphic


Model No.
Symbols Symbols

MPA-03
P T B A TA A P B TB

MPB-03
P T B A TA A P B TB

MPW-03
P T B A TA A P B TB

610 03 Series Modular Valves


MODULAR VALVES

Typical Performance Characteristics

Hydraulic Fluid: Viscosity 35 mm2/s (164 SSU), Specific Gravity 0.850

Pressure Drop Pressure Drop for Reversed Controlled Flow


PSI MPa PSI MPa
0.4 0.4
P

P
50 50
B-Line: MPA-03
Pressure Drop

Pressure Drop
40 0.3 40 0.3
A-Line: MPB-03
30 0.2 T-Line 30 0.2
20 20
0.1 0.1
10 P-Line 10
0 0 0
0
0 10 20 30 40 50 60 70 L /min 0 10 20 30 40 50 60 70 L /min

0 5.0 10.0 15.0 17.5 U.S.GPM 0 5.0 10.0 15.0 17.5 U.S.GPM
Flow Rate Flow Rate

F
Pressure Drop for Free Flow Min. Pilot Pressure
PSI MPa PSI MPa
0.8 12
110
MP*-03-4 140
100 0.7 0
Min. Pilot Pressure (PP)

PP P1 -2
10 -4
P

MP*-03-2
0.6 -0
3 20
2-

03 Series Modular Valves


80 -
120 P*
Pressure Drop

8 M - 03
0.5 P2
P*
60 M
0.4 80 6

40 0.3 4
1
0.2 40 3-4-200
2 MP *-0
20 1
0.1 3-2-200
MP -0 *
0 0
0 0 5 10 15 20 25 MPa
0 10 20 30 40 50 60 70 L /min

0 1000 2000 3000 3500 PSI


0 5.0 10.0 15.017.5 U.S.GPM
Flow Rate Supply Pressure (P2)

03 Series Modular Valves 611


MPA-03-*-20/2001
MPB-03-*-20/2001
DIMENSIONS IN
MPW-03-*-20/2001 7(.28) Dia. Through MILLIMETRES (INCHES)
4 Places
92(3.62)
19 54

(.47)
12
(.75) (2.13)

(1.81)

(2.76)
A B

46

70
TA TB

(.07)
60

1.8
(2.36)
174(6.85)

(2.17)
55

Approx. Mass............ 3.5 kg (7.7 lbs.)

Spare Parts List

MPA-03-*-20 MPB-03-*-20
7 8 5 4 3 9 2 1 6

List of Seals
Item Name of Parts Part Numbers Qty. Remarks
8 O-Ring SO-NB-P24 2 Included in Seal Kit
7 11 8 5 10 4 3 9 O-Ring SO-NB-A014 5 Kit No.: KS-MPA-03-20

Low Pilot Pressure Control Type


(MPA-03-*-2001)

MPW-03-*-20

612 03 Series Modular Valves