0% found this document useful (0 votes)
346 views195 pages

Mil STD 461c

This document establishes requirements for controlling electromagnetic interference in military equipment and systems. It supersedes MIL-STD-461B from 1980. The standard provides requirements for evaluating electromagnetic emissions and susceptibility of equipment to ensure interference is considered and controlled in design. It is approved for use by all Department of Defense agencies.

Uploaded by

gilberto araujo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
346 views195 pages

Mil STD 461c

This document establishes requirements for controlling electromagnetic interference in military equipment and systems. It supersedes MIL-STD-461B from 1980. The standard provides requirements for evaluating electromagnetic emissions and susceptibility of equipment to ensure interference is considered and controlled in design. It is approved for use by all Department of Defense agencies.

Uploaded by

gilberto araujo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 195

Downloaded from http://www.everyspec.

com

MIL-STD:461C
4 AUGUST 1986

SUPERSEDING
MIL-STD-461B
1 APRIL 1980

MILITARY STANDARD•

ELECTROMAGNETIC EMISSION AND


SUSCEPTIBILITY REQUIREMENTS
FOR THE CONTROL OF
ELECTROMAGNETIC INTERFERENCE

AMSC No. AREA EMCS


DISTRIBUTION STATEMENT A. Approved for public release; distribution Is unlimited.
Downloaded from http://www.everyspec.com

MIL-STD-461C

DEPARTMENT OF DEFENSE
WASHINGTON, DC 20402

glectromagmetic Emissions and Susceptibility Requirements


- for the :Control of Electromagnetic Interference

1. This Military:standard is approved for use by all Departments and


Agencies of the Department of Defense.

2. BenefiCiai comments (recommendations, additions, deletions) and any


pertinpnt dataishich-mny:be of use in improving this document should be
-ad:ISO:ad to: COmmander,; -Npane and Naval Warfare Systems Command, Attn:
SPAWAW003-121',:,WaShington, DC 20363-5100, by using the Self-addressed
Standardization Docuient Improvement Proposal (DD Form 1426) appearing at
the end of thin.doeUment or by letter.

ii
Downloaded from http://www.everyspec.com

MIL-STD-461C

FOREWORD

1. This standard is established to:

(a) Ensure that interference control is considered and incorporated into the
design of equipment and subsystems; and

(6) Provide a basis for evaluating the electromagnetic characteristics of


equipment and subsystems, as well as for inputs to analyses of the
electromagnetic compatibility and effectiveness of systems in a complex
electromagnetic environment.
Downloaded from http://www.everyspec.com

MIL-STD-461C
Part 2
NOTICE 2 (USAF)
15 October 1987

MILITARY STANDARD

ELECTROMAGNETIC EMISSION AND SUSCEPTIBILITY REQUIREMENTS FOR THE CONTROL OF


ELECTROMAGNETIC INTERFERENCE

TO ALL HOLDERS OF MIL-STD-461C:

1. THE FOLLOWING PAGES CONSTITUTE PART 2 OF MIL-STD-46)C FOR AIR FORCE


ACQUISITIONS:

NEW PAGE DATE SUPERSEDED PAGE DATE

2-i through 15 October 1987 2-i through 4 August 1986


2-iv 2-iv

2-1 through 15 October 1987 2-1 through 4 August 1986


2-24 2-24

2-25 through 15 October 1987


2-32

2. RETAIN THIS NOTICE AND INSERT BEFORE TABLE OF CONTENTS.

3. Holders of MIL-STD-461C shall verify that page changes and additions


indicated above have been entered. This notice page will be retained as a
check sheet. This issuance, together with appended pages, is a separate
publication. Each notice is to be retained by stocking points until the
military standard is completely revised or cancelled.

Preparing activity:
Air Force - 11

Project No. EMCS-F122

Review activities:
Air Force - 13, 14, 15, 17, 18, 19, 70, 71, 80, 82, 84, 90, 99

AMSC N/A AREA FMCS

DISTRIBUTION STATEMENT A. Approved for public release; distribution is



Downloaded from http://www.everyspec.com

MIL-STD-461C
NOTICE 1
1 April 1987

MILITARY STANDARD

ELECTROMAGNETIC EMISSION AND SUSCEPTIBILITY REQUIREMENTS


FOR THE CONTROL OF ELECTROMAGNETIC INTERFERENCE

TO ALL HOLDERS OF MIL-STD-461C:

1. MAKE THE FOLLOWING PEN AND INK CHANGE:

Self cover, after "AMSC No.", add "N3903".

2. RETAIN THIS NOTICE AND INSERT BEFORE TABLE OF CONTENTS.

3. Holders of MIL-STD-461C will verify that the page change indicated above has been entered. This
notice page will be retained as a check sheet. This issuance, together with appended pages, is a separate
publication. Each notice is to be retained by stocking points until the military standard is completely
revised or canceled.

Custodians:
Army - CR Preparing activity:
Navy - EC NAVY - EC
Air Force - 11
(Project No. EMCS-0121)
Review activities:
Army - MI, AY
Navy - SH, OS, AS, YD, MC, CO, TO
Air Force - 13, 15, 17, 19, 68, 69, 79, 99
NSA
DCA
DoDECAC

User activities:
Army - AT, ME, GL, CE, HD

AMSC No. N3903 AREA EMCS


DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited.

Downloaded from http://www.everyspec.com

MIL-STD-461C

CONTENTS

Page

Part I. General Requirements 1-1

2. Requirements for Equipment and Subsystems Installed


Aboard Aircraft, Including Associated Ground Support
Equipment (Class Al) . 2-1

3. Requirements for Equipment and Subsystems Installed •


Aboard Spacecraft and launch Vehicles, including
Associated Ground Support Equipeent (Class A2) 3-1

4. Requirements for Equipment and Subsystems Installed


in Ground Facilities (Fixed and Mobile, Including
Tracked and Wheeled Vehicles) (Class A))

5. Requirements for Equipment and Subsystems Installed


in Surface Ships (Class A4)

6. Requirements for • Equipment and Subsystems Installed


in Submarines (Class A5)

7. Requirements for Ancillary or Support Equipment and


Subsystems Installed in Non-Critical Ground Areas
(Class B) • 7-1

3. Requiremedts for Tactical and Special Purpose


Vehicles and Engine-Driven Equipment (Class Cl) 8-1

9. Requirements for Engine Generators and Associated


Components, Uninterruptible Power Sets (UPS), and .
Mobile Electric Power (ME)') Equipment Supplying
Power to or Used in Critics/ Areari (Class C2) 9-1

10. Requirements for Commercial Electrical and


Electromechanical . Equipment (Class C3)
Downloaded from http://www.everyspec.com

Part 1. General Requirements


Downloaded from http://www.everyspec.com

MIL-STD-461C

CONTENTS

Page

Part 1

Paragraph 1. SCOPE 1-1


1.1 Purpose 1-1
1.2 Application 1-1
1.3 Units 1-1
1.4 Emission and susceptibility designations 1-1

2. REFERENCED DOCUMENTS 1-1


2.1 Government documents 1-1
2.1.1 . Specifications, standards, and handbooks 1-1
2.1.2 Other Government documents, drawings, and publications 1-2
2.2 Other publications 1-3
2.3 Order of precedence 1-3

3. DEFINITIONS 1-3
3.1 Critical Area 1-3
3.2 Equipment 1-3
3.3 Interconnecting leads 1-3
3.4 Non-critical area 1-3
3.5 Sheltered subsystem 1-3
3.6 Subsystem 1-4
3.7 System 1-4
3.8 Tailoring ' 1-4
3.9 Telecommunications equipment 1-4

4. GENERAL REQUIREMENTS 14
4.1 Joint procurements 1-4
4.2 North Atlantic Treaty Organization (NATO) procurements 14
4.3 Design requirements 1-4
4.3.1 Filtering (Navy only) 14
4.3.2 Equipment or subsystems employing electro-explosive 1-4
devices (EEDs)
4.3.2.1 Air Force procurements 1-4
4.3.2.2 Navy procurements 1-5
4.3.2.3 Army procurements 1-5
4.4 Self-compatibility 1-5
4.5 Commercial off-the-shelf equipment 1-5
4.5.1 Used in equipment or subsystems 1-5
4.5.1.1 Selected by contractor 1-5
4.5.1.2 Specified by procuring activity 1-5
4.5.2 Used as an individual equipment 1-5
4.6 Government furnished equipment (GFE) 1-5
4.7 Short-duration emissions 1-5
4.8 Procurements of equipment and subsystems having met 1-5
other EMI requirements
4.9 Testing requirements 1-5

5. EMISSION AND SUSCEPTIBILITY REQUIREMENTS AND LIMITS 1-6


5.1 General 1-6
5.2 Equipment and subsystem classes 1-6

6. NOTES 1-6
6.1 Intended use 1-6
6.2 Data requirements list and cross reference 1-6
6.3 Subject term (key word) listing 1-6
6.4 International standardization agreements 1-6
6.5 Changes from previous issue 1-6

TABLES

1-I Emission and susceptibility requirements 1-7
1-II Equipment and subsystem classes vs. applicable part 1-8
of MIL-STD-461 for emission and susceptibility
requirements and limits
Downloaded from http://www.everyspec.com

NIL-STD-461C

I.. SCOPE

1.1 Purpose. This standard establishes the documentation and design requirements for
the control of the electromagnetic emission and susceptibility characteristics of electronic,
electrical, and electromechanical equipment and subsystems (as defined herein) designed or
procured for use by activities and agencies of the Department of Defense. Such equipment
and, subsystems may be used independently or as an integral part of other subsystems or
systems.

1.2 Application. The requirements of this standard are applicable to the extent
specified in the individual equipment or subsystem specification, contract or order. The
applicability of the emission and susceptibility requirements are dependent upon the type of
equipment or subsystem and its mission and intended installation. When engineering analyses
on equipment or subsystems being procured for use in specific systems or platforms reveal
that the requirements in this standard are not adequate for that procurement, they may be
tailored by the procuring activity and incorporated into the request-for-proposal, specifi-
cation, contract or order. In cases where s system or integrating contractor is required
to prepare a detailed equipment or subsystem specification containing requirements for
electromagnetic Compatibility (EMC),. including electromagnetic interference (EMI), electro-
magnetic pulse (EMP), electromagnetic (E11) radiation hazards, and so forth, the requirements
of this standard shall be tailored as needed to achieve overall required system or platform
performance. For equipment and subsystems in feasibility or advanced development stages
of the acquisition process, this standard shall be used as a guide in formulating the
appropriate requirements. Those requirements shall be enumerated in the individual equip-
ment development or purchase description.

1.3 Units. Symbols, units, and physical constants used in this standard are in
accordance with the International System of Units (SD, as described in MIL-STD-463.

1.4 Emission and susceptibility designations. The emission and susceptibility


requirements in this standard and corresponding test methods of MIL-STD-462 are designated
in accordance with an alpha-numeric coding system where:

C a Conducted
II a Radiated .
E a Emission
S a Susceptibility
UM - Unique requirement(s) intended for a miscellaneous,
general-purpose equipment or subsystem

2. REFERENCED DOCUMENTS

2.1 Government documents.

2.1.1 Specifications, standards, and handbooks. Unless otherwise specified, the


following specifications, standards, and handbooks of the issue listed in that issue of the
Department of Defense Index of Specifications and Standards (DoDISS) specified in the
solicitation form a part of this standard to the extent specified herein.

SPECIFICATIONS

MILITARY

MIL-E-6051 Electromagnetic Compatibility Requirements, Systems

STANDARDS

. MILITARY

HILaSTD-285 Attenuation Measuremente.For Enclosure, EM Shielding,


For Electronic Test Purposes, Method Of

MIL-STD-462 Electromagnetic Emission And Susceptibility, Test
Methods For

MIL-STD-463 • Definitions And System Of Units, Electromagnetic
Interference And Electromagnetic Compatibility

1- 1
Downloaded from http://www.everyspec.com

MIL-STD461C

MIL-STD-480 Configuration Control - Engineering:Changes, Deviations


And Waivers

MIL-STD-704 Aircraft Electric Power Characteristics

MIL-STD-1377 Effectiveness Of Cable, Connector And Weapon Enclosure


(NAVY) Shielding And Filters In Precluding Hazards Of Electro-
magnetic Radiation To Ordnance, Measurement Of

MIL-STD-1385 Preclusion Of Ordnance Hazards In Electromagnetic


(NAVY) Fields; General Requirements For

MIL-STD-1512 Electro-explosive Subsystems, Electrically Initiated,


(USAF) ' Test Methods And Design Requirements

MIL-STD-1541 Electromagnetic Compatibility Requirements For Space


(USAF) Systems

MIL-STD-1542 Electromagnetic Compatibility (EMC) And Grounding


(USAF) , Requirements For Space System Facilities

NATO STANAGS

NAT-STD-3516 EMC Test Methods For Aerospace Electrical and


Electronic Equipment

NAT-STD-3614 'EMC of Installed Equipment In Aircraft

NAT-STD-3659 • Bonding Andln-Flight Lightning

HANDBOOKS

MILITARY

MIL-HDBR-235 , Electromagnetic (Radiated) Environment Considerations


For Design And Procurement Of Electrical and Electronic
Equipment

MIL -HDBR-237 Electromagnetic Compatibility Management Guide For


Platforms, Systems And Equipment

MIL -MDBK-241 Design Guide For EMI Reduction In Power Supplies

MIL-HDBR-253 Guidance For The Design And Test Of Systems Protected


Against The Effects Of Electromagnetic Energy

2.1.2 Other Government documents, drawings, and publications. The following other
Government documents, drawings, and publications form a part of this standard to the extent
specified herein.

PUBLICATIONS

AIR FORCE SYSTEMS COMMAND (AFSC)

AFSC DH 1-4 Air Force Systems Command Design Handbook, EMC

AFSC DH 2-5 Air Force Systems Command Design Handbook, Armament

AFSC DH 2-7 Air Force Systems Command Design Handbook, System


Survivability .

US ARMY AMC MATERIEL READINESS SUPPORT ACTIVITY

AMC Pamphlet 706-235 Hardening Weapon Systems Against RE Energy

AMC Pamphlet 706-410 Engineering Design Handbook, EMC

1-2
Downloaded from http://www.everyspec.com

MIL-STD-461C

SPACE AND NAVAL WARFARE SYSTEMS COMMAND (SPAWAR)

NAVELEX 0101, 106 Nava/ Shore Electronics Criteria, EMC/EMR Hazards


NAVAL SEA SYSTEMS COMMAND (NAVSEA)

NAVSEA OD 30393 Design Principles And Practices For Controlling


Hazards Of Electromagnetic Radiation To Ordnance

(Copies of specifications, standards, handbooks, drawings, and publications required


by contractors in connection with specific acquisition functions should be obtained from
the contracting activity or as directed by the contracting officer.)

2.2 Other publications. The following document(s) form a part of this standard to the
extent specified herein. Unless otherwise specified, the issues of the documents which are
DoD adopted shall be those listed in the issue of the DoDISS specified in the solicitation.
The issues of documents which have not been adopted shall be those in effect On the date of
the cited DoDISS.

SOCIETf OF AUTOMOTIVE EhUINEERS (SAE)

SAE J551 Measurement Of Electromagnetic Radiation Prom Motor


Vehicles

SAE AIR 1423 -Electromagnetic Compatibility On Gas Turbine Engines


For Aircraft Propulsion

SAS AIR 1425 Methods Of Achieving Electromagnetic Compatibility Of


Gas Turbine Engines Accessories, For Self-Propelled
Vehicles

(Application for copies should be addressed to the Society of Automotive Engineers . , Inc.,
400 Commonwealth Drive, Warrendale, PA 15096.)

(Nongowernment standards are generally available for reference from libraries. They are
also distributed among nongovernment standards bodies and using Federal agencies.)

2.3 Order of precedence. In the event of a conflict between the text of this standard
and the references cited herein, the text of this standard shall take precedence.

3. DEFINITIONS

The terms used in this standard are defined in MIL-ST0-463. In addition, the following
definitions are applicable for the purpose of this standard:

3.1 Critical area. A location on a platform or installation containing equipment or


subsystems which, if malfunctioning due to unwanted electromagnetic energy, could degrade the
overall system performance and result in failure or abortion of a primary mission. All
locations on a submarine and surface ship are considered critical areas.

3.2 Equipment. Any electrical, electronic, or electromechanical device, or collection


of items, intended to operate as an individual unit and perform a singular function. As used
herein equipment include, but are not limited co, the following: receivers, transmitters,
transceivers, transponders, power supplies, electrical off its machines, hand tools, processors,
test apparatus and instruments, and material handling equipment. -

3.3 Interconnecting leads. Control and signal lines which interface with equipment or
subsystems not being supplied under the same contract. Control leads use AC or DC power for
control of such devices as relays, solenoids, valves, machinery control sensors, and synchros;
whereas signal leads send or receive such signals as clock, IF, audio, digital, and RF.

3.4 Non-critical area. A /ocation_in a ground installation where EMI will not result in
failure or abortion of a mission or degradation of the overall system performance. Examples
of areas which may be considered non-critical are office buildings, recreational areas,
laundry areas, food servicing areas, drafting rooms, and woodworking shops.

3.5 Sheltered subsystem. Equipment or components designed specifically for installation


in standard military shelters, which comply with MIL-STD-285 and Which are not intended to
meet the natural environments, such as humidity, temperature, and so forth.

1-3
Downloaded from http://www.everyspec.com

MIL-STD-4610

3.6 Subsystem. For the purpose of this standard; the definition in 3.6a or 3.66 shall
be considered as a subsystem. In either case, the devices or equipment may be physically
separated when in operation and will be installed in fixed or mobile stations, vehicles, or
systems.

a. A collection of devices or equipment designed and integrated to function as a


• single entry, but wherein any device or equipment is not required to function
as an individual equipment, as defined in 3.2.

b.• A collection of equipment and subsystems, as defined in 3.6a, designed and


integrated to function as a major subdivision of a system and to perform an
operational function, or functions, therein. •

3.7 Sy stem. A composite of equipment, subsystems, skills, and techniques capable of


performing or supporting an operational role. A complete' system includes related facilities,
equipment, subsystems, materials, services; and personnel required for its operation to the
degree that It can be considered self-sufficient within its operational or support environment.
(EMC requirements for systems are not included in this standard, but rather in such documents
as MIL-E-6051, MIL-STD-1541, and MIL-STD-1542.)

3.8 Tailoring. The process by which the requirements of this standard are adapted (that
is, modified, deleted, or supplemented) to the peculiarities, characteristics, or operational
requirements of the material in an individual equipment or subsystem specification. The
tailoring process does not constitute a waiver or deviation. The latter terms are defined in
MIL-STD-480.

3.9 Telecommunications equipment. Any equipment which transmits, emits, or receives


signs, signals, writing; images, sounds, or information of any nature by wire, radio, visual,
or other electromagnetic means.

4. GENERAL REQUIREMENTS

Electronic, electrical, and electromechanical equipment and subsystems shall comply with
the applicable requirements in 4.1 through 4.9. These requirements are in addition to the
applicable emission and susceptibility requirements and limits defined in other portions of
this standard.

4.1. Joint procurements.. Equipment or subsystems procured by one DoD activity for multi-
agency use shall comply with the requirements of the user agencies. :

4.2 North Atlantic Treaty Organization (NATO) procurements. Equipment or subsystems


procured by a DoD activity in support of NATO shall comply with the applicable requirements
of this standard and any applicable NATO standardization agreement (STANAG), such as NAT-STDs
-3516, -3614, and-3659. The NATO STANAGs'are not to he waived, deviated from, or tailored
unless specific authority has been granted by the procuring activity.

4.3 Design requirements. Equipment and subsystems shall be designed in accordance with
the criteria and guidance contained in the following documents, as applicable: MIL-HDEK-235,
MIL-HDBK-237, MIL-HDB*-241, MIL-RDBK-253, AFSC OH 1-4, AFSC D9 2-5 and AFSC DH 2-7, AMC
Pamphlets 706-235 and 706-410, and NAVELEX 0101, 106. '

4.3.1 Filtering (Navy only!. The use of line-to-ground filters for EMI control shall be
minimized. Such filters establish low impedance paths for structure (common-mode) currents
through the ground plane and-can be a major cause- of interference in systems, platforms, or
installations because the currents can couple into other equipment using the same ground
plane. If such a filter must be employed, the total line-to-ground capacitance shall not
exceed 0.1 microfarads (u s ) for 60 hertz (Hz) equipment or 0.02 pF for 400 Hz equipment. The
filtering. employed shall be fully-described in the equipment or subsystem technical manual,
as well as the EMI Test Report. The procuring activity shall determine the applicability of
this requirement for class Al equipment and subsystems.

4.3.2 Equipment or subsystems employing electro-explosive devices (EEDs). When EEDs are
employed in, or are an integral part of, equipment or subsystems required to meet the require-
ments of this standard, the EED and associated wiring shall, meet the requirements in 4.3.2.1,
4.3.2.2, or 4.3.2.1, as applicable.

4.3.2.1 Air Force procurements. AFSC DH 2-5 shall be used as a design guide, and
compliance with M/L-STD-1512 . ehall be accomplished.

1-4
Downloaded from http://www.everyspec.com

MIL-STD-461C

4.3.2.2 Navy procurements. Compliance with MIL-STD-1385 shall be accomplished, and


OD 30393 shall be used as a design guide in implementing the principles outlined in MIL-
STD-1385. In addition, MIL-STD-1377 shall be used to determine the effectiveness of cable,
connector, and weapon enclosure shielding and filtering. For air weapons, all circuits shall
be isolated from the equipment or subsystem case, and the case bonded to the airframe.

4.3.2.3 Army procurements. The requirements of 4.1.2.1 and 4.3.2.2 shall be used as
specified in the procurement documentation.

4.4 Self-compatibility. The operational performance of an equipment or subsystem shall


not be degraded, nor shall it malfunction when all of the units or devices in the equipment
or subsystem are operating together at their designed levels of efficiency or their nominal
design capability.

4.5 Commercial off-the-shelf equipment.

4.5.1 Used in equipment or subsystems.

4.5.1.1 Selected by contractor. When it is demonstrated by the contractor that a


commercial item selected by the contractor is responsible for an equipment or subsystem
failing to meet its contractual EMI requirements, either the commercial item shall be modified
or replaced or interference suppression measures shall be employed, so that the equipment or
subsystem can meet its contractual EMI requirements.

4.5.1.2 Specified by procuring activity. When it is demonstrated by the contractor


that a commercial item specified by the procuring activity for use in an equipment or sub-
system is responsible for failure of the equipment or subsystem to meet its contractual EMI
requirements, the data indicating such failure shall he included in the EM/ Test Report. No
modification not replacement shall be made unless authorized by the procuring activity.

4.5.2 Used as an individual equipment. Commercial equipment without any previous EMI
certification shall meet the applicable requirements in Parts 2 through 10 of this standard.

4.6 Government furnished equipment (an). When it is demonstrated by the contractor


that a GEE is responsible for failure of an equipment or subsystem to meet its contractual
EKI requirements, the data indicating such failure, along with descriptions of possible
modifications to the GFE, shall be included in the EMI Teat Report. No modification shall be
made unless authorized by the procuring activity.

4.7 Short-duration emissions. Radiated and conducted transient emissions, resulting


from automatic cycling of electronic or electrical switching circuitry and manually controlled
operational mode switching functions required for normal operation of the equipment or sub-
system, shall meet all applicable requirements of this standard.

4.8 Procurements of equipment or subsystems having mat other EMI requirements.


Procurements of production-type equipment and subsystems electrically and mechanically
identical to those previously procured by activities of DoD or other Federal agencies, or
their contractors, shall meet the EMI requirements and associated limits, as applicable in
the earlier procurement, unless otherwise specified by the Command or agency concerned.
For Navy procurements, production-type equipment shall be tested to all the applicable
limits of this standard, but shall meet the EMI requirements and associated limits as
applicable in the earlier procurement, unless otherwise specified by the Command or agency
concerned. All data shall be provided is the Eta Test Report.

4.9 Testing requirements. The testing requirements and procedures of MIL-STD-462, as


implemented by a Government approved Eta Test Plan (See 6.2), shall be used to determine
comp/lance with the applicable emission and susceptibility requirements of Section 5 and
Parts 2 through 10 of this standard. When performing susceptibility testing, the thresholds
of susceptibility shall be determined mad reported in the EMI Test Report, whether below
the contractual EMI requirement or above, within the maximum capability of the test equipment
used. Data gathered as a result of performing tests in one electromagnetic discipline may be
sufficient to satisfy requirements In another. Therefore, to avoid unnecessary duplication,
a single test program should be established with similar tests conducted concurrently
whenever possible. Equipment that are intended to be operated as a subsystem shall be
tested, as such, to the applicable emission and susceptibility requirements and limits
whenever practical. Formal testing is not to commence without approval of the test plan
by the Command or agency concerned.

1-5
Downloaded from http://www.everyspec.com

MIL-STD-461C

5. EMISSION AND SUSCEPTIBILITY REQUIREMENTS AND LIMITS

5.1 General. Table 1-I is a list of emission and susceptibility requirements established
by this standard. General test procedures for these requirements are contained in MIL-STD-462.
All results of testa performed to demonstrate compliance with these requirements are to be
documented in the EMI Test Report (See 6.2) and forwarded te the Command or agency concerned
for evaluation prior to acceptance of the equipment or subsystem. Design procedures and tech-
niques for the control of EMI shall be described in the EMI Control Plan (See 6.2). Approval
of design procedures and techniques described in the EMI Control Plan does not relieve the
supplier of. the responsibility of meeting the contractual emission, susceptibility, and design
requirements. The test report shall be required by the contract and is to be forwarded to the
Command or agency concerned-for.evaluation prior to acceptance of the equipment or subsystem.

5.2 Equipment and subsystem classes. Table 1-II defines equipment or subsystem classes
in accordance with their intended installation, platform, and mission. In addition, Table 1-II
denotes the applicable part of this standard wherein emission and susceptibility requirements
and limits are specified. When an equipment or subsystem falls into more than one class, it
shall comply with the most stringent of the applicable requirements and limits.

6. NOTES

6.1 Intended use. This standard is intended for use in the acquisition cycle of equip-
ment and subsystems to specify the electromagnetic emission and susceptibility requirements
for the control of EMI.

6.2 Data requirements list andcross reference. When this standard is used in an
acquisition which incorporates a OD Form 1423, Contract Data Requirements List (CDRL), the
data requirements identified below shall be developed as specified by an approved Data Item
Description (DD Form 1664) and delivered in accordance with the approved CURL incorporated
into the contract. When the provisions of the DOD FAR Supplement 27.410-6 are invoked and
the DD Form 1423 is not used, the data.specified below shall be delivered by the contractor
in accordance with the contract or purchase order requirements. Deliverable data required
by this standard is cited in the following subparagraphs.

Applicable Para. Data requirement Applicable DID

5.1 Electromagnetic Interference Control Plan DI-EMCS-80199


4.9 Electromagnetic Interference Test Plan DI-*ICS-80201
5.1 Electromagnetic Interference Test Report DI-EMCS-80200

(Data item descriptions related to this standard, and identified in section 6 will be approved
and listed as such in DoD 5000.19-1..., Vol. II, AMSDL. Copies of data item descriptions required
by the contractors in connection with specific acquisition functions should be obtained from
the Naval Publications and Forms Center or as directed by the contracting officer.)

6.3 Subject terM(key word). listing.

.FMC
EMI
EMP
Electromagnetic compatibility
Electromagnetic emission
Electromagnetic interference
Electromagnetic pulse
Electromagnetic susceptibility
Filters, line-to-ground capacitance
Test Limits, DU
Teat Methods, EMI

6.4 International standardization agreements. Certain provisions of this standard


(See 4.2) are the subject of international standardization agreements (NAT-STD -3516, -3614,
and -3659). When amendment, revision, or cancellation of this standard is proposed which
will modify the international agreement concerned, the preparing activity will take
appropriate action through international standardization channels, including departmental
standardization offices to change the agreement or make other appropriate accommodation.

6.5 Changes from previous issue. Asterisks or vertical lines are not used in this
revision to identify changes with respect to the previous issue due to the extensiveness
of the changes.

1-6
Downloaded from http://www.everyspec.com

MIL-STD-4610

, TABLE 1-I. EMISSION AND SUSCEPTIBILITY REQUIREMENTS.

Requirement Description

CE01 Conducted Emissions, Power and Interconnecting Leads,


Low Pregnancy (up to 15 kHz)
CE03 Conducted Emissions, Power and Interconnecting Leads,
0.015 to 50 MHz
CEO& Conducted Emissions, Antenna Terminals 10 kHz to 26 Gil:
CE07 Conducted Emissions, Power Leads, Spikes, time Domain

CS01 Conducted Susceptibility, Power Lends, 30 Hz to 50 kHz


CS02 Conducted Susceptibility, Power and Interconnecting Control
Leads, 0.05 to 400 MHz
CS03 Intermodulation, 15 kHz to 10 GHz
CSO4 . Rejection of Undesired Signals, 30 Hz to 20 Glitz
CS05 Cross-modulation, 30 Hz to 20611:
CS06 Conducted Susceptibility, Spikes, Power Leads
6507 Conducted Susceptibility, Squelch Circuits
6509 Conducted Susceptibility, Structure (Common Mode) Current,
60 Hz to 100 kHz
6510 Conducted Susceptibility, Damped Sinusoidal Transients,
Pins and Terminals, lOidiz to 100 MHz
6511 Conducted Susceptibility, Damped . Sinusoidal Transients,
Cable,, 10 kHz to 100 MHz

RE01 Radiated Emissions, Magnetic Field, 0.03 to 50 kHz


RE02 Radiated Emissions, Electric Field, 14 kHz to 10 GHz
RE03 Radiated Emissions, Spurious and Harmonics, Radiated Technique

RSOI Radiated Susceptibility, Magnetic Field, 0.03 to 50 kHz


11502 Radiated Susceptibility, Magnetic and Electric Fields,
Spikes and Power Frequencies
R503 Radiated Susceptibility, Electric Field, 14 kHz to 40 GHz
R505 Radiated Susceptibility, Electromagnetic Pulse Field Transient

1M03 Radiated Emissions and Susceptibility, Tactical and Special


Purpose Vehicles and Engine-Driven Equipment
UM04 Conducted Emissions and Radiated Emissions and Susceptibility,
Engine Generators and Associated Components UPS and MEP
Equipment .
tiM05 Conducted and Radiated Emissions, Commercial Electrical and
Electromechanical Equipment

/-7
Downloaded from http://www.everyspec.com

MIL -STD“4-61C

TABLE 1-II. EQUIPMENT AND SUBSYSTEM CLASSES VS. APPLICABLE PART


OF MIL-STD-461 FOR EMISSION AND SUSCEPTIBILITY
REQUIREMENTS AND LIMITS.

Applicable
Class Description Part
A Equipment and subsystems which must operate -
compatibly when installed in critical areas,
such as the following platforms and installationst

Al Aircraft (including associated ground support equipment) 2

Spacecraft and launch vehicles ( including associated 3


ground support equipment)

Ground facilities (fixed and mobile, including 4


tracked and wheeled vehicles)

A4 Surface ships

AS Submarines 6

B Equipment and subsystems which support the Class A 7


equipment and subsystems, but which will not be
physically located in critical ground areas.
Examples are electronic shop maintenance and test
equipment used in non-critical areas, theodolites,
navaids, and similar equipment used in isolated areas.

C Miscellaneous, genera/ purpose equipment and subsystems -


not usually associated with a specific platform or
installation. Specific items in this class are;

Cl Tactical and special purpose vehicles and engine-driven 8


equipment

C2 Engine generators and associated components,


uninterruptible power sets (UPS) and mobile
electric power (ME?) equipment supplying power
to or used in critical areas

C3 Commercial electrical and electromechanical 10


equipment

1 -8
Downloaded from http://www.everyspec.com

MIL-STD-481C

Custodians Preparing Activity:


Army - CR Navy -EC
Navy - EC (Project EMCS -0112)
Air Force - 11

Review Activities
Army - MI, AV
Navy - SR. OS, AS, YD, MC, OG, TD
Air Force - 13, 15, 17, 19, 68, 69, 79, 99
NSA
DCA
DoDECAC

User Activities:
Army - AT, ME, GL, CE, HD

1-9/ 1-10
Downloaded from http://www.everyspec.com

Part 2. Equipment and Systems Installed


Aboard Aircraft, Including Associated
Ground Support Equipment (Class Al)
Downloaded from http://www.everyspec.com

MIL-STD-461C
Part 2
NOTICE 2 (USAF)
15 October 1987
CONTENTS

Part 2 Page

Paragraph 1. SCOPE 2-1


1.1 Determining requirements 2-1
1.1.1 Air Force and Navy procurements 2-1
1.1.2 Army procurements 2-3

2. CE01 (limited applicability) 2-3


2.1 CE01 applicability 2:1
2.2 CEO! limits 2-3
2.2.1 AC, DC, and interconnecting control leads 2-3
2.2.2 Interconnecting signal leads 2-3

3. CE03 2-5
3.1 CE03 applicability 2-5
3.2 CE03 limits 2-5
3.2.1 AC, DC, and interconnecting control leads 2-5
3.2.2 Interconnecting signal leads 2-5

4. CE06 (limited applicability) 2-5


4.1 CE06 applicability 2-5
4.2 CE06 limits 2-5
4.2.1 Receivers 2-5
4.2.2 Transmitters (key-up and standby) 2-6
4.2.3 Transmitters (key-down mode) 2-6

5. CEO? 2-6
5.1 CEO? applicability 2-6
5.2 CEO? limits 2-6

6. CS01 (limited applicability) 2-6


6.1 COI applicability 2-6
6.2 CS01 limits 2-6

7. CS02 2-7
7.1 CS02 applicability 2-7
7.2 CS02 limits 2-7

8. CS03 (limited applicability) 2-7


8.1 CS03 applicability 2-7
8.2 CS03 limits 2-7

9. CSO4 (limited applicability) 2-7


9.1 CSO4 applicability 2-7
9.2 CSO4 limits 2-7

10. CS05 (limited applicability) 2-8


10.1 CS05 applicability 2-8
10.2 CS05 limits 2-8
2-8

2-i
Downloaded from http://www.everyspec.com

MIL-STD-461C
Part 2
NOTICE 2 (USAF)
15 October 1987
CONTENTS - Continued

Part 2
Page

Paragraph 11. C906 2-8


11.1 CS06 applicability 2-8
11.2 CS06 limits 2-8

12. CS07 (limited applicability) 2-8


12.1 .CS07 applicability 2-8
12.2 CS07 limits 2-8
12.2.1 Requirement 1 2-8
12.2.2 Requirement 2 2-9

13. C509 (limited applicability) 2-9


13.1 CS09 applicability 2-9
13.2 CS09 limit 2-9

14. CSIO (limited applicability) 2-9


14.1 CSIO applicability 2-9
14.2 CSIO limit 2-9

15. CS11 (limited applicability) 2-9


15.1 CSII applicability 2-9
15.2 CS11 limit 2-9

16. CS12 2-10


16.1 C512 applicability 2-10
16.2 CS12 limits 2-10

17. CS13 2-10


17.1 CS13 applicability 2-10
17.2 CS13 limits 2-10

18. RE01 (limited applicability) 2-10


18.1 RE01 applicability 2-10
18.2 RE01 limit 2-10

19. RE02 2-10


19.1 RE02 applicability 2-10
19.2 RE02 limits 2-11
19.2.1 Narrowband electric field emissions 2-11
19.2.2 Broadband electric field emissions 2-11

20. RE03 (limited applicability) 2-11


20.1 R&03 applicability 2-11
20.1.1 Army procurements 2-11
20.1.2 Air Force and Navy procurements 2-11
20.2 RE03 limit 2-11

21. RS01 (limited applicability) 2-11


21.1 RS01 applicability 2-11
21.2 RS01 limit 2-12

2-ii
Downloaded from http://www.everyspec.com

NIL-STD-461C
Part 2
NOTICE 2 (USAF)
15 October 1987
CONTENTS - Continued
Part 2 Page

Paragraph 22. RS02 2-12


22.1 RS02 applicability 2-12
22.1.1 Part I - spikes 2-12
22.1.2 Part II - power frequency 2-12
22.2 R502 limits 2-12
22.2.1 Part 1 - spikes 2-12
22.2.2 Part II - poser frequency 2-12

23. R503 2-12


23.1 RS03 applicability 2,-12
23.2 RS03 limits 2-13
23.2.1 Air Force and Navy equipments and subsystems
installed in non-metallic aircraft, non-metallic
structure or externally mounted on metallic aircraft 2-13
23.2.2 Air Force flight critical equipment and subsystems 2-13

24. RS05 (limited applicability) 2-13


24.1 RS05 applicability 2-13
24.2 RS05 limits 2-13

25. RS06 2-14


25.1 R506 applicability 2-14
25.2 R$06 limits 2-14

TAELES

2-1 Categories of class Al equipments and subsystems


(Air Force and Navy use) 2-1
2-11 Emission and susceptibility requirements
for class Al equipments and subsystems
(for Air Force and Navy use) 2-2
2-III Emission and susceptibility requirements
for class Al equipments and subsystems
(for Army use) 2-4

FIGURES

2-1 Limit for CE01 narrowband emissions 2-15


2-2 Limit for CE03 naroowband emissions 2-16
2-3 Limit for CE03 broadband emissions 2-17
2-4 Limit for CSOI 2-18
2-5 Limit for C$04 2-19
2-6 Acceptable waveshapes for C506 and RS02 2-20
2-7 Limit for C509 2-21
2-8 Limit for CSIO 2-22
2-9 Limit for CSII 2-23

Downloaded from http://www.everyspec.com

MIL-STD-461C
Part 2
NOTICE 2 (USAF)
15 October 1987
CONTENTS - (Continued)

Part2 Page

2-10 Limit for RE01 2-24


2-11 Limit for RE02 narrowband emissions 2-25
2-12 Limit for RE02 broadband emissiions 2-26
2-13 Limit for RS01 2-27
2-14 Limit for RS05 2-28
2-15 Waveform for CS12 2-29
2-16 Limit for CS12 2-30
2-17 Waveform for CS13 2-31
2-18 Limit for CS13 2-32

2-iv
Downloaded from http://www.everyspec.com

MIL-STD-461C
Part 2
NOTICE 2 (USAF)
15 October 1987
1. SCOPE

This part of MIL-STD-461 supplements Part 1 of the standard by defining


emission and susceptibility requirements and limits for equipment and
subsystems intended for use aboard aircraft (class Al), including associated
non-shipboard ground support equipment and for class A3 equipment and
subsystems procured for the Air Force.

LI Determining requirements

1.1.1 Air Force and Navy procurements. Table 2-1 defines categories of
class Al equipment and subsystems. Table 2-11 shall be used to determine
the requirements applicable for equipment and subsystems procured for Air
Force or Navy use. The table also denotes the paragraphs where in the
requirements and limits are defined. A '7" entry in the table means the
requirement is applicable, and the limit shall be met using the procedures
in MIL-STD-462 or the approved EMI Test Plan. A 1 7/. " entry means the
applicability of the requirement is limited and is specified in the appro-
priate corresponding paragraph. The limit shall be met using the proce-
dures in MIL-STD-462 or the approved EMI Test Plan. A "1" entry means
that the applicability of the requirement must be determined on a case-by-
case basis and, if the requirement is to be imposed, it must so specified in
the appropriate procurement document. When required, the limit shall be met
using the procedures in MIL-ST0-462 or the approved EMI Test Plan. Absence
of an entry means the requirement is not applicable.

TABLE 2-1. Catepories of class Al equipment and subsystems.


(For Air Force and Navy use)

Category Description

Ala Air launched missiles

Alb Equipment installed on aircraft (internal or external to


airframe)

Ale Aerospace ground equipment required for the checkout and


launch of the aircraft, including electronic test and
support equipment

Aid Trainers and simulators

Ale Portable medical equipment used for aeromedical airlift

All Aerospace ground equipment used away from the flight-


line, such as engine test stands and hydraulic test
fixtures

Alg Jet engine accessories

Alh Class A3 equipment procured for Air Force use

2-1
Downloaded from http://www.everyspec.com

MIL-SID-451C
Part 2
YA3LE 2-II. Emission and susceptibility requirements for class Al
NOTICE 2 (USAF
equipment and •ubsystets (For Air Force and Navy Use).
15 October 196 •
..--
Categories of class Al
equipment and •ubaitems Applicable

Requirement Ala Alb Sic Aid Ale Alf Mg Alb Paragraph Limit Curve

CE01 YL 2 2-1
TL
CE03 T 7 7 ITYY 7 3 2-2,2-3

CE06 Y 7 7 7 1. 4
L L L
CE07 IMF T 5

CSOI MIT 7 7 6 2-4

CS02 I YYYTTY

CS03 Y I T
L
a
L TL L
CSO4 T T EL 9 2-5
'TL L L
CS05 Y T 10
L TL L YL TL
CS06 Y 1 Y 1 Y 1 7 11 2 -6

Cs07 I 1 12
L L
.
CS09 lf 13 2-7
L
CSIO 7777777 14 2-8

CS11 15 2-9
YL YL IL IL IL
CS12 T 1 Y 16 2-15, 2-16

CS13 Y 7 Y 17 2-17, 2-18

RE01 Y 18 2-10
L
R1102 Y Y Y YYYY 19 2-11,2-12

RE03 T T T T 20

RS01 7 I 21 2-13
L
R302 YTYYYTY 7 22 2-6

RS03 YYYYY 7 Y Y 23

RS05 YY Y-YYYY 24 2-14


LLLLLLL
R506 T 7 7 25
,

1/ SEE SAE AIR 1423 AND 1425 FOR ADDITIONAL GUIDANCE ON TAILORING.

2/ CATEGORY Ale AND Alf EQUIPPENT PROCURED FOR NAVY SHIPBOARD USE
c ?"" MEET THE APPLICABLE CLA IR PART 5 OF
ItIls STANDARD.
Downloaded from http://www.everyspec.com

MIL-STD-46IC
Part 2
NOTICE 2 (USAF)
15 October 1987
1.1.2 Army procurement's. Table 2-111 ,shall be used to determine the specific
requirements for class Al equipment and subsystems procured for Army use.
The table also denotes the paragraphs wherein the requirements and limits
are defined. A "Y" entry in the table means the requirement is applicable,
and the limit shall be met using the procedures in MIL-STD-462 or the approved
ENI test plan. A Y entry means the applicability of the requirement is
limited and is specified in the appropriate corresponding paragraphs. When
applicable the limit shall be met using the procedures in MIL-STD-462 or the
approved ENI test plan. A "T" entry means that the applicability must be
determined on a case-by-case basis and, if the requirement is to be imposed,
it must be specified in the appropriate procurement document. When required,
the limit shall be met using the procedures in MIL-S1D-462 or the approved
ENI Test Plan. Absence of an entry means the requirement is not applicable.
For procurements of subsystems, such as radar, LW, surveillance, navigation,
and the like, comprised of individual equipment listed in table 2-111, the
applicable emission and susceptibility requirements for the subsystem shall be
tailored by the procuring activity based on the requirements of the individual
equipment.
2. CE01 (limited applicability)

2.1 CE01 applicability. This requirement is applicable for equipment


and subsystems installed on aircraft having an anti-submarine warfare
(ASW) capability and for Navy equipment and subsystems intended for use on
aircraft and having Very Low Frequency ( VLF) subsystems and equipment. When
required, CE01 is applicable only for narrowband emissions between 30 Hz and
15 kilohertz (kHz) on alernating current (AC) and direct current (DC) leads,
which obtain power from other sources or provide power to other equipment or
subsystems; grounds or neutrals, which are not grounded internally to the
subsystem or equipment being measured; and, for Army and Navy procurements,
interconnecting control leads which provide AC and DC power from or to the
test sample. The requirement is not applicable for interconnecting signal
leads such as clock, IF, audio, firing, digital, RI, and the like, unless
otherwise specified by the Command or agency concerned.

2.2 CE01 limits

2.2.1 AC, DC, and interconnecting control leads. Electromagnetic emissions


shall not appear on AC, DC, and, where required, interconnecting control
leads in excess of the values as shown on figure 2-1. The limits shall be
met when measured with an effective bandwidth not exceeding the primary
power frequency plus 20% of the power frequency for AC power leads or 75 Hz
for DC power leads.

2.2.2 Interconnecting signal leads. If compliance with this requirement


is required for signal leads, limits shall developed on a case-by-case basis
considering the intentional transmission, its specified power level, necessary
information bandwith, and pulse rise time. Such limits must be approved by
the Command or agency concerned.

2-3
Downloaded from http://www.everyspec.com

Requirement
D nnnnnno
Vi 0 0 VI 0 fr
n 0 n n
en Specific
VI Col VI 01 rf1 VI 01 in 0'
000 0 0 0 0 0 0 0 0 0 0000
L.) cr. ul a “i 01 la -• quipment/SutsyStem
< < -I < -4 -I -4 < ,< -I < < -4 ROCOWI

< << < < r< -1 -C < -I Teener.

< < < <-C ' -4 <-4 atithi nna Mulbcoupleit


r

< < <-4-4


-I -I < < -4 < -4 Amoblef, Tuned. Ai
r
F rn
< < < <-C
r
-I •C < Amp1.1-.t. Untuati, R

< -4 < < <-C -I -C < lateitomilmerphpfle


a

< < < < p< -I < -4 Moat in


iii
< < < <-C
a-
-4 <-4 R &pi Ales

-< -4
-4 -C -( < -C -I < Am plat .te, Poiiref!Avelio rn CO
4-
CO
Mpiduleof
< AC < <-C
4.
-4 <-4

Multipleleft
C 5
< < < < p< -4 <-4

-C < < CC -4 <-4 LAW Cit•.4et

< < < <-C


r
-4 <-4 iR Oencet a
< < < < -1 -4 -I <-C -4 < <-4 TiensPordef t
e C
< <'C < < < -4 < < -4 Beacons CO
4-
<-4 < -C < ..< -I <-4 Po.vcr 5g01:11.11 rn
CO
-C -i -n -C < <-C -i <-4
Senior antennas C -4
co
< -4 -4 < < -4 <-I Inertial Cud:lugs
-C -C csn
<-4 < < <-C -1 -C -4 TII444414wriiitrt
r
<-4 < < <-C Ail
4 AC A4 Racaideft
a- rTl
XI
A< < < <-C -4 < -4 Visual OnPlett I11
cn 0
<-4 < < <-C -4 < -4 4311111 CAuiglinnI
"ri
n
< < -C <-C -4 <-I 044i4 An/salmon 51.
a-' 0 171
< < < -C -C -I <-4 Celina Ona
r
171
< -4 < < < r< al <-4 !Manama SYI80

<-4 < < < <



-4 <-1 StrIO/STIChre

< < "C <-C


4-
-I < -I Telt EtiuiPittimi C 11
CO
-C < < <-C -I < -4 Ton4/Filq uenty STD/

AC < VItentiful 011.40 0
<-C Ail <-4
r
< A l < < AC < 444 AC A I lip horn
r CO
AC sow tiSomvliion
AC < -C
r
-C -I < Va
< AC A C <-C
contmaciall
< • AC <
AC 4 •C -4 •4 4.-4 -4 -4 All OlAins Net (.44.4144eisiA

41 .4 -a .6 ... 4 GI '4 0 0 0 1J 9.1 • o pl<mil • 44 -


• CPI :II *. ••• 0
tg6t dcto)ao c r
Z 30 EiON

Ilaid

(917-Clis-'1114
Downloaded from http://www.everyspec.com

MIL-STD-461C
Part 2
NOTICE Z (USAF)
15 October 1987
3. CE03

3.1 CE03 app)icability. This requirement is applicable for the following


types of leads: AC and DC leads, which obtain power from other sources or
provide power to other equipment, distribution panels, or subsystems; ground
or neutrals, which are not grounded internally to the subsystem or equipment
being measured; and, for Army and Navy procurements, interconnecting control
leads which provide AC and DC power from or to the test sample. The require-
ment is not applicable for interconnecting signal leads such as a clock, IF,
audio, firing, digital, radio frequency (RI), and the like, unless otherwise
specified by the Command or agency concerned. For Army procurements, the
requirement is applicable using the Line Impedance Stabilization Network, as
described in MIL-STD-462.

3.2 CEO) limits

3.2.1 AC DC, and interconnecting control leads. Electromagnetic emissions


shall not appear on AC, DC, and, where required, interconnecting control leads
in excess of the values shown on figures 2-2 and 2-3 for narrowband and
broadband emissions, respectively. For Navy and Air Force procurements,
conducted switching spike emissions (including ON/OFF switching) on AC and DC
power leads shall meet the requirements of CE07.

3.2.2 Interconnecting signal leads. If compliance with this requirement is


required for signal leads, limits shall be developed on a case-by-case basis
considering the intentional transmission, its specified power level, necessary
information bandwidth, and pulse rise time. Such limits must be approved by
the Command or agency concerned.

4. CE06 (limited applicability)

4.1 CEO& applicability. This requirement is applicable for those equip-


ment and subsystems with antenna leads or those designed to be connected to
antennas. The transmitter (key-down mode), harmonic, and spurious emission
portions of this requirement are not applicable for equipment and subsystems
Frocured solely for Army use, when any of the following conditions exist:
(a) transmitter power exceeds 5 kilowatts (kW) average, (b) the fundamental
frequency of the test sample exceeds 1.24 gigahertz (CHz), (c) the test
sample's antenna is an integral part of the transmitter and cannot be replaced
by suitable dummy load, or (d) for equipment and subsystems with waveguide
transmission lines and operating below 1.24 Wiz. For cases (a) through (d) use
RE03. The frequency range of this requirement is dependent on the operating
frequency of the test sample (see MIL-STD-462). The transmitter (key-down)
portion of this requirement is not applicable within either the test sample's
necessary bandwidth or it5 percent of the fundamental frequency.

4.2 CEO& limits. Conducted emissions in excess of the values given 4.2.1
through 4.2.3 shall not appear at the test sample's antenna terminals.

4.2.1 Receivers

a. Narrowband emissions: 34 decibels above l microvolt (dBu V)

b. Broadband emissions: 40 dro V/megahertz (MNz)

2-5
Downloaded from http://www.everyspec.com

MIL-STD-461C
Part 2
NOTICE 2 (USAF)
15 October 1987
4.2.2 Transmitters (key-up and standby)

a. Narrowband emissions: 34 dBli V

b. Broadband emissions: 40 dap V/Mliz

4.2.3 Transmitters (key-down mode). Harmonics, except the second and


third, and all other spurious emissions shall have peak powers 80 decibels
(dB) down from the power at the fundamental. The second and third harmonics
shall be suppressed by: 50 + JO log P (where P peak power, in watts, at
the fundamental) or 80 dB, whichever requires less suppression.

5. CE07

5.1 CE07 applicability. This requirement is applicable for Air Force


and Navy procurements for the following types of leads: AC and DC leads
which obtain power from or provide power to other equipment or subsystems.

5.2 CE07 limits. Conducted switching spikes of less than 50 microseconds


in duration shall not exceed the following, as applicable:

a. AC leads: 150 percent of nominal rms voltage.

b. DC leads: +50 percent, -150 percent of nominal line voltage.

Conducted switching spikes equal to or greater than 50 microseconds in


duration shall meet the transient requirements of MIL-STD-704. Spike
duration is the time interval between the 502 amplitude point on the
transient leading edge and the 502 amplitude point on the transient trailing
edge; high frequency ringing superimposed on the pulse leading or trailing
edges should be ignored.

6. - CSOI (limited applicability)

6.1 CSOI applicability. This requirement is applicable to equipment


and subsystem AC and DC power leads, including grounds and neutrals which
are not grounded internally to the equipment or subsystem. This requirement
is not applicable within ±5 percent of the power frequency(ies). For Navy
procurements, this requirement may be deleted for AC leads, with the
approval of the command or agency concerned, if no circuit within the
equipment or system is more sensitive than 100 millivolts (mV). For
equipment and subsystems procured solely for Army use, this requirement is
applicable for DC leads only.

6.2 CSOI lirits. The test sample shall not exhibit any malfunction,
degradation of performance, or deviation from specified from specified
indications, beyond the tolerances indicated in the individual equipment or
subsystem specification, when subjected to electromagnetic energy injected
onto its power leads equal to the values on figure 2-4. The requirement is
also met when the power source specified in CSOI of MIL-STD-462, adjusted to
dissipate 50 watts in a 0.5 ohm load, cannot develop the required voltage at
the test sample power input terminals, and the test sample is not susceptible
to the output of the signal source.

2-6
Downloaded from http://www.everyspec.com

M1L-STD-461C
P ar t 2
h0114 2 tUSAF,
15 October 1987
7. CS02

7.1 C502 applicability. This requirement is applicable to equipment and


subsystem AC and DC power leads, including grounds and neutrals which are
not grounded internally to the equipment or subsystem.

7.2 CS02 limits. The test sample shall not exhibit any malfunction,
degradation of performance, or deviation from specified indications, beyond
the tolerances indicated in the individual equipment or subsystem specifi-
cation, when subjected to 1-volt from a 50 ohm source. The test signal
shall be applied directly to the equipment input terminals, not through the
test sample's power line cord. The requirement is also met when a 1-watt
source of 50 ohms impedance cannot develop the required voltage at the test
sample power input terminals, and the test sample is not susceptible to the
output of the signal source.

8. CS03 (limited applicability)

8.1 CS03 applicability. This requirement is applicable to receiving


equipment and subsystems, such as receivers, RF amplifiers, transceivers,
and the like. The applicable frequency range of this requirement is
dependent on the operating frequency of the test sample as specified in
MIL-STD-462.

8.2 C503 limits. The test sample shall not exhibit any intermodulation
products from two signals, beyond those permitted in the individual equip-
ment or subsystem specification, when

a. Signal generator 01 is set 66 dB above the level required to obtain the


standard reference output, as specified in MIL-STD-462; except that when
f t is in the frequency range of either 200 to 400 MHz or 2 to 25 MHz, the
generator output shall be 80 dB above the reference level, but the output of
signal generator hl shall not exceed 10 dBm:

b. Signal generator 02 is set 66 dB above the level required to obtain the


standard references output, as specified in MIL-STD-462, but the generator
output level shall not exceed a power level of JO dllm.

9. CSO4 (limited applicability)

9.1 CSO4 applicability. This requirement is applicable to receiving


equipment and subsystems, such as receivers, RI amplifiers, transceivers,
and the like. The applicable frequency ranee of this requirement is
dependent on the operating frequency of the test sample, as specified in
MIL-STD-462.

9.2 C504 limits. The test sample shall not exhibit any undesired response
when subjected to the test signal shown on figure 2-5.

2-7
Downloaded from http://www.everyspec.com

MIL-STD-461C
Part 2
14 01,CE 2 (USAr,
15 October 1987
10. CS05 (limited applicability)

70.1 CS05 applicability. This requirement is applicable to receiving


equipment and subsystems such as receivers, RE amplifiers, transceivers, and
the like. The applicable frequency range of this requirement is dependent
on the operating frequency of the test sample, as specified in M1L-STD-462.

10.2 CS05 limits. The test sample shall not exhibit, due to cross
modulation, any malfunction, degradation of performance, or deviation from
specified indications, beyond the tolerances indicated in the individual
equipment or subsystems specification, when subjected to the following from
signal generator 02: a signal 66 dB above the level required to obtain the
standard reference output, as specified in M1L-STD-462, but not to exceed a
power output level of 10 dBm.

11. CS06

11.1 CS06 applicability. This requirement is applicable to equipment and


subsystem AC and DC power leads-, including grounds and neutrals which are
not grounded internally to the equipment or subsystem.

11.2 CS06 limits. The test sample shall not exhibit any malfunction,
degradation of performance, or deviation from specified indications, beyond
the tolerances indicated in the individual equipment or subsystem specifi-
cation, when the test spikes having the wavvform shown on figure 2-6 are
applied to the AC and DC power input leads for a period of not less than 1
minute at each phase position, and for a total test period not exceeding 15
minutes in duration (in lieu of the values in MIL-STD-462). The values of
1( ) and t ( ) are given below. Each spike shall be superimposed on the
powerline voltage waveform.

a. Spike PI 200 Volts; t1 10 microseconds 201


(All Services)

b. Spike f2 E = 200 Volts; t2 = 0.15 microseconds 20%


2
(Air Force and Navy)

12. CS07 (limited applicability)

12.1 CS07 applicability. This requirement is applicable for receiving


equipments and subsystems which utilize squelch circuits.

12.2 CS07 limits

12.2.1 Requirement 1. Squelch circuits shall not open when the output
of a 50-ohm impedance impulse generator, set at 90 dEgiV/Mliz, is applied and
matched to the input terminals of the test sample.

2-8
Downloaded from http://www.everyspec.com

H1L-STD-461C
Pert 2
NOCICE 2 tUSAF)
15 October 1987
12.2.2 Requirement 2. The squelch circuit shall not open when two signals
are applied at the input of the test sample. One signal shall be an unmodu-
lated RE signal at the receiver tuned frequency, whose amplitude is two-thirds
of the RI voltage used to adjust the squelch threshold. The second signal
shall be an impulse signal of 50 dBpV/Mliz.

13. C$09 (limited applicability)

13.1 CS09 applicability. This requirement is applicable to Navy equipment


and subsystems that have an operating frequency range of 100 kHz or less and
an operating sensitivity of IpV or less, such as 0.5JV.

13.2 CS09 limits. The test sample shall not exhibit any malfunction,
degradation of performance or deviation from specified indications, beyond
the tolerances indicated in the individual equipment or subsystem specifi-
cation when subjected to the levels shown on figure 2-7 across the appli-
cable test' points.

14. CSIO (limited applicability)

14.1 CSIO applicability. This electromagnetic pulse (Eli?) requirement


is applicable to Navy equipment and subsystem interface pins and terminals
of power leads, control leads, signal leads, and grounds and neutrals which
are not grounded internall:: to the equipment or subsystem. Applications
of requirement are to be determined on a case-by-case basis. It should
be noted that if the equipment is to be installed in an intentionally
unhardened aircraft, the equipment will not be adequately protected against
the specified EM?.

14.2 CSIO limit. The test sample shall not exhibit any permanent malfunc-
tion, degradation of performance, or deviation from specified indications,
beyond the tolerances and recovery times indicated in the individual equip-
ment or subsystem specification, after being subjected to a test signal
having either the waveform and common mode current level shown on figure 2-8,
as determined in accordance with HIL-STO-462.

15. CS11 (limited applicability)

15.1 CS11 applicability. This EMP requirement is applicable to Navy equip-


ment and subsystems having interconnecting or intraconnecting control, signal,
or power cables. This requirement is not applicable for equipment intended
solely for use on non-metallic aircraft, unless otherwise specified by the
procuring activity. It should be noted that if the requirement is to be
installed in an intentionally unhardened aircraft, the equipment will not be
adequately protected against the specified electromagnetic pulse (EMP).
Actual cable types, sizes and configurations subjected to the specified RS05
levels are exempt from meeting this requirement.

15.2 CS11 limit. The test sample shall not exhibit any permanent malfunc-
tion, degradation of performance, or deviation from specified indications,
beyond the tolerances and recovery times indicated in the equipment or sub-
system specification, after being subjected to a test signal having the wave-
form shown in figure 2-9 and having a maximum bulk common mode cable current
of 10 amps, as determined in accordance with MIL-STD-462.

2-9
Downloaded from http://www.everyspec.com

MIL-STD-461C
Part 2
NOTICE 2 MAO
15 Octoter 1987
16. CS12

16.1 CS12 applicability. This requirement is applicable to equipment and


subsystems procured for Air Force use.

16.2 C812 limits. The test sample shall not exhibit any malfunction,
degradation of performance, or deviation from specified indications, beyond
the tolerances allowed by the individual equipment or subsystems specifi-
cation, when the current waveform of figure 2-15 is induced at 10 kHz, 100 kHz,
1 MHz, 10 MHz, and 100 MHz in each interconnecting and power cable at the peak
current level specified on figure 2-16. Additional test frequencies(partic-
ularily between I and 50 MHz) shall apply when required by system design con-
siderations or when required by the procuring activity. When a 1500 volt level
is reached between any pin and its lowest impedance return the requirement of
this test shall be considered to be met.

17. CS13

17.1 CS13 applicability. This requirement is applicable to equipment and


subsystem procured for Air Force use.

17.2 CSI3 limits. The test sample shall not exhibit any malfunction,
degradation of performance, or deviation from specified indications, beyond
the tolerances allowed by the individual equipment or subsystem specifi-
cation, when a pulse signal is applied to each single wire or multiple wire
unit (twisted pair, tries, etc.) of the interconnecting and power leads.
The pulse signal shall produce the current and voltage waveform of figure
2-17 at the levels shown on figure 2-16 when applied to calibration loops.
Test frequencies shall be 10 kHz, 100 kHz, 1 MHz, 10 MHz and 100 MHz. Addi-
tional test frequencies (particularity between 1 MHz and 50 MHz) shall when
required by system design considerations or when required by the procuring
activity.

18. RE01 (limited applicability)

16.1 no] applicability. This requirement is applicable only for equip-


ments and subsystems installed in aircraft having an ASW capability and for
Navy equipment and subsystems intended for use on aircraft having Very Low
Frequency (VLF) equipment and subsystems. When required, RE01 is applicable for
radiated emissions from equipments and subsystems, cables (including control,
pulse, intermediate frequency (IF), power antennas transmission lines) and
interconnecting wiring of the test sample. The requirement applies at the
fundamental frequencies and all spurious emissions, including harmonics, but
does not apply for radiation from antennas.

16.2 RE01 limit. Magnetic field emissions shall not be radiated in excess
of the levels shown on figure 2-10.

2-10
Downloaded from http://www.everyspec.com

MII-Srn-46lm
Part 2
NOTICE 2 (USAF)
15 October 1987
)9. RE02

19.1 RE02 applicability. This requirement is applicable for radiated


emissions from equipments and subsystems, cables (including control, pulse
IF, power and antennas transmission lines) and interconnecting wiring of the
test sample; for narrowband, it applies at the fundamental frequencies, and
all spurious emissions including harmonics, but does not apply for radiation
from antennas. This requirement is applicable for broadband emissions from
14 kHz to 1 GHz and for narrowband emissions from 14 kHz to 10 GHz.

19.2 RE02 limits. E-field emissions shall not be radiated in excess of .


those given in 19.2.1 and 19.2.2. Above 30 MHz, the limits shall be met for
both horizontally and vertically polarized waves.

19.2.1 Narrowband electric field emissions. Narrowband E-field emissions


shall not be radiated in excess of the applicable limit curve shown on figure
2-11 at the required test distance, as specified in MIL-STD-462.

19.2.2 Broadband electric field emissions. Broadband E-field emissions


from all equipments and subsystems, including radiated switching transients
resulting-from (1) automatic cycling of electronic or electrical switching
circuitry, (2) actuation of push-to-talk mechanisms (that •is keying of trans-
mitters), or (3) manual switching shall not be radiated in excess of the
applicable limit curve shown on figure 2-12 at the required test distances,
as specified in MIL-510-462.

20. RE03 (limited applicability

20.1 RE03 applicability. This requirement is applicable for transmitting


equipments and subsystems with antenna leads or those designed to be connected
to antennas. The frequency range of this requirement is dependent on the operating
frequency of the test sample (see MIL-STD-462). The requirement is not applicable
within either the test sample's necessary bandwidth or 5 percent of the funda-
mental frequency.

20.1.1 Army procurements. This requirement is applicable for trans-


mitting equipments and subsystems procured solely for Army use when any of
the following conditions exist: (a) transmitter power exceeds 5 kW average;
(b) the fundamental frequency of the test sample exceeds 1.24 GHz; (c) the
test sample's antenna is an integral part of the transmitter and cannot be
replaced by a suitable dummy load; or (d) for equipments and subsystems with
waveguide transmission lines and operating below 1.24 GHz.

20.1.2 Air Force and Navy procurements. This requirement is applicable,


with the approval of the procuring activity, when the transmitter spurious
emissions and harmonics cannot be determined using the procedures in CEDE.

20.2 RE03 limit. Harmonics, except the second and third, and all other
spurious emissions shall have peak powers 80 dB down from the power at the
fundamental. The second and third harmonics shall be suppressed by: 50 • 10
t
log P (where P f peak power, in watts, at the fundamental) or 80 dB whichever
requires less suppression.

2-11
Downloaded from http://www.everyspec.com

MIL-STD-461C
Part 2
NOTICE 2 (USAF)
15 October 1987
21. RS01 (limited applicability)

21.1 RSOI applicability. This requirement is applicable only for equip-


ments and subsystems installed in aircraft having' an ASW capability, and for
Navy equipment and subsystems intended for use on aircraft having Very Low
Frequency (VLF) equipment and subsystems. When required, RS01 is applicable
to equipments and subsystems, and their associated cabling and connectors.

21.2 RSOI limit. The test sample shall not exhibit any malfunction,
degradation of performance, or deviation from specified indications, beyond
the tolerances indicated in the individual equipment or subsystem specifi-
cation, when subjected to magnetic fields equal to the levels shown on
figure 2-13.

22. RS02

22.1 R502 applicability. This requirement is applicable to equipment and


systems as indicated in 22.1.1 and 22.1.2.

22.1.1 Part I - spikes. This portion of RS02 is applicable for all


Department of Defense (DOD) activities.

22.1.2 Part ii - power frequency. This requirement is applicable for


equipments and subsyst2ms procured for Air Force and Navy uce.

22.2 RS02 limits

22.2.1 Part I - spikes. The test sample shall not exhibit any malfunction,
degradation of performance, or deviation from specified indications, beyond
the tolerances indicated in the individual equipment or subsystem specifi-
cation, when subjected to the test spikes having the waveform shown on figure
2-6. The values of E( ) and t ( ) are given below:

a. Spike al El = 200 Volts; t 1 = 10 microseconds ±201.


(All Services)

b. Spike P2 E2 = 200 Volts; t 2 = 0.15 microseconds ±207;


(Air Force and Navy)

22.2.2 Part II - power frequency. The test sample shall not exhibit any
malfunction, degradation of performance, or deviation from specified indica-
tions, beyond the tolerances indicated in the individual equipment or sub-
system specification, when 20 amperes are applied to the test wire at the
power frequency(ies) of the test sample.

23. RS03

23.1 RS03 applicability. This requirement is applicable for all equipment


and subsystem between 14 kHz and 10 GHz. Above 10 GHz, this requirement
applies only at all intentionally generated frequencies of known intentional
emitters on the aircraft, and for Navy procurements, the aircraft's host
ship. For Air Force procurements, this requirement is not applicable above
10 GI12, unless otherwise required by the procuring activity.

2-12
Downloaded from http://www.everyspec.com

MIL-STD-461C
Pert 2
NOTICE 2
15 October 1987
23.2 - RS03 limits. The test sample shall not exhibit any malfunction,
degradation of performance, or deviation from specified indications beyond
the tolerances indicated in the individual equipment or subsystem specifi-
cation when subjected to the radiated electric fields (E) specified herein.
Above 30 MHz, the requirement shall be met for both horizontally and verti-
cally polarized waves; circurlarly polarized waves are also acceptable.
Appropriate consideration shall be given to the operational radiated electro-
magnetic environment from both friendly and hostile . emitters which an equip-
ment or subsystem may encounter during its life cycle. Applicable portions
of MIL-HDBK-235 shell be used to determine the anticipated environment. As
a minimum, the following levels apply. If levels substantially higher than
those given herein are specified, modifications to the procedure in MIL-STD-
462 may be required or desirable. Such modifications are to be described
in the EMI Test Plan.

Frequency Range E-Field (Volts/Meter (V/m))

14 kHz to 2 MHz 20, except that for Army procurements


the level is 1 V/m
2 to 10 GHz 20
Above 10 GHz 20

23.2.1 Air Force and Navy equipments and subsystems installed in non-metallic
aircraft, non-metallic structures on metallic aircraft or externally mounted
on metallic aircraft. Such equipments shall not malfunction when subjected
to a reclined E-field of 200 V/m over the required frequency range.

23.2.2 Air Force flight critical equipment and subsystems. Equipment and
subsystems which are flight critical shall not malfunction when subjected to
a radiated t-field of 200 V/m from 14 kHz to 10 GHz.

24. RS05 (limited applicability)

24.1 RS05 applicability). This requirement is intended for Navy equip-


ment and subsystems and is applicable whenf both of the following conditions
exist: (a) operation of the equipment or subsystem is essential for safety
or the success of a mission and (b) the equipment or subsystem is installed
on anon-metallic structure on a metallic aircraft or externally mounted on
on a metallic aircraft. This requirement is not applicable for equipment
intended solely for use on non-metallic aircraft, unless otherwise required
by the procuring activity. Cables that can not be tested in accordance with
MIL-STD-462 shall meet the requirements of CS11, and cables subjected to the
specified CS11 levels are exempt from meeting this requirement.

24.2 RS05 limit. The test sample shall not exhibit any permanent malfunction
degradation of performance, or deviation from specified indications,beyond the
tolerances and recovery times indicated in the individual equipment or subsystems
specification, after being subjected to a test signal having thewaveiorm and
amplitude shown on figure 2-14.

2-13
Downloaded from http://www.everyspec.com

MIL-STD-46IC
Part 2
-eVliCt. 2
is October 1987
25. - RS06

25.1 RS06 applicability. This requirement is applicable to equipment and


subsystems procured for Air Force use.

25.2 RS06 limits. The test sample shall not exhibit any malfunction,
degradation of performance, or deviation from specified indications, beyond
the tolerances allowed by the individual equipment or subsystem specification
while being subjected to a radiated eletromagnetic field generated by fast
switching pulses from a relay coil. The peak-to-peak transient voltage across
the relay coil shall be a minimum of 600 volts.

2-14

Downloaded from http://www.everyspec.com

3 4 5 • 7 •
1 2 3 • 5 4 7 11 , !:
1 3 • 5 il 7 II •,
• .3 • 7 • 11 -

li 11,IptII
. 1 IP.
;1
11 1::1 !. i. Yi 1
I i i . I
I 1 I
. ,11,, ir.II, kW
Til 1, ,I. d . • li li
FIGURE 2-1
!

I II.'
III 1 1, II I! /1

;I.. 111i lii. 1'Al Isill LIMIT FOR CE01 m


1,'

140
11[1 II
:
i l l Iii 1
.., . 4

1. 1. ilif...1.1 10 lip
4-
1
111
,111,hil
I
jjt
. . ..,,..11
••
1 . , ..
111 11
;;;11 1 III t.'
NARROWBAND EMISSIONS
. • . ne, 1411 .1

130 1 I I, 1...1,.."'ll" 1
!ilk
}.1 .1
"It
.. I '' ',I. i t, 7 11: 11"i I I i
;II; 4
„.,.,
;
I „ ,.. i ,
1 : . ; : II I: il l: II IIII
I. lNed
i il.'.. :ILI;
ir i Ili
1
1 11;1 11' '.1 11 ,1:11
1.1.111.1111.i. 11..110 0 1 0. ir
ii. i 1 ;3 .1 1 I I 1 11 ill : I ill;al
r; Li:
- - Ill.:::.
; I I ' . '.I1 . .1 .0 1.:1 ...i...' 1.;..
120 -I , 1 . 1-.1:.
I:
0
!I t 1; ! i l ;11;III 'i;nk
I i z. III. ; •
L ' ; 1;1 :;'/ •!' ;;: 2 .1*. • •11
lli iii. l ' :.. ' ri;11.1 1 I" I, ..... ...., .. !I I '',.7.,.. , .11, . 1 ,.. 1., i ..,. ,., .
1; 3;1 .,
11 1 1 1111111:11 1:1: SI:141 1. P11.1.1. i i rip l.! 1:1;..;...........:. • : V: 1,1 ... V.I.. a ...'.-4 ; , ; , 1,:1 1: :1;1 :1.11r;
110 .. .. ... „ , , , • • •1 ..: : /...; .1;4
,..; i . 1 I 111 1,1 ;;•.•

i
1 II 1111 ; . .,... 1 . .
II i: ; /.1 1, ; ... I I ..il l ,..
1,11 .1:' .. ." ..1 • t . ., • , .. .1.1
._
100 --1/1 i t tit P:1411-:J:::+ : :I .• ! • : , .., ,.1... . . J
li'li .111 11,11:11 ; .::: ...: ril: .. .1
1 1 I. 4:r I/11It.
a I 1
II: 1 I I : I I,: ;:::,•:: ..• •
11 i III ,•:', :: : I.III 1:,.....2
.' :II : :.. -
go . ; . - ci'
. I:1 ,
-
11,1flii.1.1:: 1! . .; ... 1, , 1
I I ! II
111 1 ! ti, ..ii,111.i;'.''''.1. 11.1, li. 11 II
i 1 •-l
: . :•:: .::•ii:!:LI
80 !lilt . iii.IL:'•....;-. • 4111. 4. i 1 I. -Pp-

I I III 1 1 II: 1,,, 1 . .,;! :14 . 1 1, 11, 1.1: 1 : iii l'.. . . •
't
I is '„ . i ,. : •
I. I ! • 1 II, i ll. ,..1 .„ • '' 'I" ..
70 . 1 11 1 I n ,t:1 ,i 1. . „.. ... ••••

••.
.„ ... , 1...-1 ,.• ,.
11111,141.111.1:i '.....:::;• •1F: -... '. 1 .. ...:1 :T. .... '..'
l'.
60ii4... ni P i, J. 4;4
' h i 1 11 ,1...i.,;..Y.:',,, r,a-,:lli.
IN I II::
•I
••
•1 1.: •
II;
11'
,

'
.
:',.... ... • ' 21 :: ..,.
.,.. .
I: : : 1••• • 14-.1
I Il .
-r
" ..
'..'".
1 ...........
..
..,..
;,-.,: r.r.' .
1:1.1.1::'.!!'• !1:•,._ : :. '.
50 il ilt1 ti,r:
• .1
! H i I I ;I! ,',..i...;:r.',..-.11:1;
I ; F:1
I II
i i
I
1 Ili ip. , .,
I " . 1 I
1 ; :i •
, 0::; •.
, . 1 ..„;
1 .1 • is.•
.• ,....:sc. . 1
p I I i I I .- - S n

..; .i• .. ,
1.1.1...,1
1
F.! LI I I '1
.• 1 ' I:1
ii ' I ' 1" ....ILI. 1 I ti ; . -1. l ili. “11; .. • 1-,7-7 "r1-
i -„ • I l•
, ' 1 I I *. P .;;!: : .,.; .•... I.' •

1
. I 1,.. • !,•:,.. • .;. s.L.: . ... ,... .;, , .
1 1 - . , . I' • - , . a. -,1.- i
.4., - ..•
....
; 1 It.; ; ; I : . 1,, s . ..... ...,1!,,.. ... : .,....... •... --
I ; :1 . F REOUEN :Y Hz 1 1., ., ...... .., I l'.. ....I.- •• • • - •
Ii 1 1 I ; I i ii:I 2*.,:r. ill . 1.1 .: ,
1 IN 11 1 , 11 „, 11 !'t i r,', .:..;!: r . 1; 1 ; ; I 1 . ..' ..'p ,...r. !r
I I Il I illtil k .., ;Fiji'? r. 1-;
- ill i ill ;Mtn ii ILI ' 1'1'1- ill IP .th....
lo 100 lk 10k 100k

FIGURE 2-1. LIMIT FOR CE01 NARROWBAND EMISSIONS



Downloaded from http://www.everyspec.com

1 3 • 3 67sI , t.
3 436 799.
36
I

/p
I .t
,111 :11111111 111111 1111111111F1'i'itli
1
FIGURE 2-2
id 11

I
LIMIT FOR CEOS
t
NARRO;BAND EMISSIONS
I I:1111 I It II I I 1:11' .1

I I

11 I 411 I

I
I
1 I.
ail la./ I
90 .1.
1• " . ; 7
I.
80 111 :Liti 11.114
...e.:. 11.111: .1

70
Li I I I
;1).11111
1;1 .
, a I.
I,: 1'

60
Ii.

50 • n ..
I
iii14; 1 I LI I:: I .1 :t l!
1 I In • •
I.1 i
i
.•.

40
• 1111 I :SI .
l
I IIL: 1.11111:11:
30 NOTE : For close Ale equipment and 111 1 1 11 11:1
1 III 1"
11 I .1..11I
;: i .611 1111..

subsystems procured for Navy or Air • 1

20 Force use, the Omit shall be relaxed ;. I :


1111
• .0.:
I I"
10d8 over the entire frequency range, I I
1111
:I "I:
1 1I
Sill III.r''
I
I .
1111 •1 li l 1 .11
I 1.1;T

I 101 11
24•11.11 1111


0.01 0.1 10

FIGURE 2-2. LIMIT FOR CE03 NARROWBAND EMISSIONS


Downloaded from http://www.everyspec.com

r•
3 13 6703
• 6 769•
I 31 7 9.
-
• S
• 3 766 .

T-I 1,i1.; 1;1 13 1, 1 1:C ' .1 I 1111 1. - 1,111111 11 i:: i 1 III


1 1 III: l i. p „I II 111 '' . i rliil il 1'II; 11111
1 " 1 1 1111 is Ill 11 11 1 .11 1i 11 11,11 1 11:H; Ill "
I 1 1 1. 1i.. ;11;;;;1111:, 'I : III ,Iili, ar '
1 I' l l ij i .111.111 .11 li .1 1 II
.111211,1

140
I Hi i iii.i iiI! IIII I IJ :
j II:. lilt . 1 1 II ,Il ijit


I 1 1 1 ilh 1.1,1! 14114.1.
I 'I l''..1 it

I
4
II.; 1 il II I II II:
'Ili I. :'I! .,
,,„, , N
/
1
I
1
I
,
I. I : I
,,,,•
FIGURE

LIMIT FOR CE03


-
23 r IIP
.

li
I
II:::- 1
„,„•„ „ ., .
., ii . . ROADEIAND &MISSIONS
i.l i 13
• • . . I „ vi I.
• i I II; I:, I., ...,
_ I i I ; 9; 11, `' ”, I l - ' • i i 1 ,1 1. 1 : 1 . 1 1,111144 II
130 I III . , ....: • •-•
i CURVE* ' ' 1 ,11 14I I 1 II. I : I I 1I ;''I L
I II, . , ' 1 4 ' ' 1' t1 . ' H:I i l II!',1.!,.
...! ' ' I "II

120
• ii
I.
1 I I
0
1;;
!WI...
ily.,“: 0,
-e I
a.
(NAVY and AIR FORCE)
_ . . ..
I:
II
••• . 1,
" •:;•;.:
,
i 1...
I

!
I
V 1 1 1. ti....1..

•;
I,
1
. •." .. •I
11.1
,..s.J. .
: -
1.
!I
. .1.• ..1 ...1 ..

' • 1 I., a.1 :;:',11,',...,


I i, ...1 1_1., _
. " ..11 ,r. 1: i lli •r.
I,
',II I.
.0 :
!:1 1
k
110 ' " • : 1... T.' •• ..t ...ti.. I. ...
1
IMI • 1
I ' I 11 - . 1. ` . '

100
i 1 1 4_ • . "I
t 1 %. II. 7'7'
II •„. lop
: : •. „:.:
..•
..
r
.

+1
. ; ..
..
.....
1. „
'
j
,

..
1 ..
1 1 " 7. '

! ..1 . 1 ;1'.•11.1';'"t
.1 1.•
:.:: 1
90 . ,

CD ...• 1 /. ...t
1 13 j" '' " • CURVE . ..
. l'• " i: • , ..,; .1.'.... . •• .•
I . .. I (ARMY/
1 '
.. ,.. ....... _
BO H .: : 9... ......1..1... .1/. ,..i. ; ! 1, I T ''.* :: " -
.
i . 1.1. .. . . • ..1, •

70
'1 " 11 '' n I I C
1. ../ / a

lid/ 11/ 1 ••
1 ..• .,

:
li i
. • i , . 1

; .
„. ...

, .1.. ,_ ;
. .

• ' '
• 1.
: ....
- 1.11 •
. 11i
.....•
1

1
Ili; n 1 1 : 11 . 11 I , NI L 1
60 1 l Il1, . • 1-1 L " ii . 6! ' . I : r. .". i;1lir ..
.. NOTE: For class Ale equipment and • 1 ! : ''' !
i '' - ' • 1. . n .1 1. ' ::',.. 1.:;
:1 1 .i 4
subsystems procured for Navy or Air
50 1 1 .•

"." ,. .
it!: Force usecurve
• , .,
1ntire
, *2 shall be relaxed
0d8 averfrequency
e range
I
. • 11 1 I Ii,I liar

I.. I. .I If 1. 11: .9,..: '


. ,..1
1 ..,!: It, LH' 'ir ',.' :It 2
. 111
40 i ,: Il ,

i i hir.r.... 1; .
711 .. . 1 ; ! ! 11 I . ; i

:4, ii.::•:••,• .. .
, .. ;
:......._,L.
F
FREQUENCY (MHz) .1 ;, ...r. ,
;;,...•
1:.:•.• • :
..

.
1
1 ,.
.. ....
1 • cll. ••:.
:!•.!: Hill :. I.:. .r..

WI 110; : 14, •••


it":
; III
• '
;;: • , il '. I I, , "“ • .• • 1 • t 1 1 1 1 .1 1 .9 '' *is
d l IP' 1.1: 111 '011411 • hi inki ill I I 1111
. 1 ' 0 '' IV I LE /1:I' 01 flteel
it' 1 1

0.01 0.1 1 10 00

FIGURE 2-3. LIMIT FOR CE03 BROADBAND EMISSIONS


Downloaded from http://www.everyspec.com

2 3 4 SS ?It I
2 3 4 Ss7sIt 7 3 4 II 2114-
2 3 41 347421
ei rau „ rt 1 gifIlgerg 11011
i 11h ,IN,Iii
Fli
.
I 1 I I1P 11; , ra I /I%
N5 1%
I 31. In I ligi ell:
II IIIIIII li t I
1
I II: FIGURE 2- 4 ill
1111
i , . 1
1
LIMIT FOR C501
!;
"4 . Fi i [Iil l p . J • iim":i
II I

1 , A

1 . I 1 •1i, 1-
n
1 11 '
11.1,111
:. )1[1: i :
na .. -
L ; ilt ic,1 o

5 I E. 1
[Ii
1 V
I ril I • I,d hill 111
r ;01.;. . . •
i 0....,„
• II " Hi " Fl
..
.. g,
1
I „ .:• . 4 ! i: 0 : i , Ir.I, II n i i
., a...:. . 1. • l i, 1 i, 1, , _. . 411

A 1 . ,II I 11,
r.• I - 1 1 'I L .: , i: t;
11. .
t ;r,11

I . I .
I li1 iti -.: i 1 ;! E
1111,:h

I ' i:• I ' " 1 11 .1 .


11 i
I

1, !.. 4 .,
1
,
,
.
ht. . - iligili ! iiiiiiiiiiill
ii!illl 71j i •1 1 hi ininiki
1
.11,1
1111111IIIMI111111

CC

2 ;it 8 „Iiii...,• 'H y., 1 111 1 1 :1 il i:. - II i La •P

I '—':
..
> ;;":
ni
• . .' I „ I O n; ;. iii
C
lli.r) 1 :1. 11 III!
nu

4 1' ; r. • It '..i. i
.1
1J

: I li . .i116 . i l IN II ri . ; :i'ii!':',.4.r -Lit; 1 II.1 :1 41. .d 1 3 : : n: 1 11 4 1' ii;;I:,:s1.1 a


Line E i to E 2 50Hz to .5 kHz) • 10% .. 1 l l oio
1 t • t 11 1 t I Ildli l JAIL:

lil t 1. 1 ., .
I r. .11 I . 1 tr:. 2

1 I
1.•,,., 1., it,
, t 1 i, . I
.. n
I i :iit.20 o supply voltoos 5 Volts U rns
Of .. fi ll,. 1 . 1 I ' 1. . ill I. .ti l ii 11 . I ii; iditi. g
. ,. • I, 0. / , i : / p i it le 2
.. 'whichever is less, but not loss than 1..1 - • 'ue w

III lja 1 Volt (fins) lIns E 2 to E 3 Is obtained 1 i'l, lig 1 l


i ,!. 4 i i•
. . i1t,
.1 01 II 111:.1... by drawing a straight line from the . ll' I I O
'7 1 1 1 , I I. ..X• . ...
1 • ••
i
R 1O1 i l I I
i1 . ..i I •:.!..
' I . odjusted poin £2 the fixed porn E 3 . . :II lh l ''' i l I I l l 11 11111L.
9 I. I .

,
It
,
..it

II
ri
IP'
Iv 1 . i I i.
m NI' . . (''li -Li
4

I
t• I
I
1 .
• I1' .

i
..
i' • ii• IA
!. 1 Iii il Ii, LI a la 1
1
FREQUENCY (Hz) 1 1
i. .
, ri
1
hi
il i
11'11 19
f T :III! ..)1 . 1
, 11 I I, pliti
1 i
gar
4 gw.Egt


I .1?
4

.u..
1 I


Li • • i -lifiitritooggpil
, .


r.,,, 1 1 " i n 1,

,.. Ira sit
iG 100 Ik 10k 100k

FIGURE 2-4. LIMIT FOR CS01


Downloaded from http://www.everyspec.com

MIL-STD-461C
Par t 2
NOTICE 2 . (USAT )
15 October 1967

0 --II

fo 0 Receiver tuned frequency or band center for amplifiers.

fi Lowest tunable frequency of receiver band in use or the lowest frequency


of amplifier passband.

f2 • Highest tunable frequency of receiver hind In use or the highest frequency


of amplifier passband.

Bandwidth between the 80 dB points of the receiver selectivity curve as defined


in the test sample's technical requirements or the control plan.

Limits:

1. The limit at A Is 80 dB above the input level required to produce the standard
reference output. (This limit shall not be used for amplifiers)
2. The limit at B shall be set as follows:
a. Receivers: 0 dam applied directly to the receiver Input terminals.
b. Amplifiers: The limit shall be as specified in the test sample's technical
requirement or control plan. If no limit Is defined In the above documents,
the 0 dBm value shall be used.

FIGURE 2-5. LIMIT FOR CSO4

- 1a
Downloaded from http://www.everyspec.com

E t)

N.7 Time

NOTE: The test sample shall be subjected to the spike(*) with the waveform shown and
with the specified voltage (s) and puisewidth (s).

FIGURE 2-6 ACCEPTABLE WAVESHAPES FOR CS06 AND R502


Downloaded from http://www.everyspec.com

7" 7 • 6 7 a 9
3 4 3 6 7 II
3 4 3 6 7 9 ,
2 3 • Si laS
Fl.
1i 1.1 1
el
ii
li ill:, 1 it

1
1,1 •

t / II 4
i . ' I •
i ,• .,
; i I 11 nil
,.
I i',
I I!
II 1.,..i

1
0
I• .4.
1 MI
I 0:Ei

. „ Iti;
ti .,__, I
1 II „ 1 -. INN
•IP

• •

I I

• 'pd '
;II
. 113
. 4 ' ll
I:: )
,
•,
2 , I
a" • . ,
I 1 1;;
. :I),
I I ;1'1 liii
I,
.1
II:: 11

1 1
II' ::
1 . I19pr
jjL
. i I. 11
1 . 1 : i 1. I !ill 1 1 iti
ra•
120 4

:: : i f I 11 : '.1: 1 ''' ..d. i ll *;


...

1 i • l: i" I' .'•


.:', I
:A •
_.. . .1 ,E.V.": ,. : I , • v. ' .. ,:.' 1.7: .............

I .. .
".'.'
110 • •
i ; i.• , •-•

. - •
r
::: . :: P,' :I' L .: St 11 — g I:
100
a 41 - • • . " ;.... "- 1
z. .;• .1. .
90 . • : a) ,., .4, • • •
..
• •
... ,........ .

i
.0i . 1 .T...... II • • •.
I, • • - • ... . •
•••• -

80 •
"1" I
- "'
I
., •
I ,
1 II
.
• 'Intl
-. . ... ,r
-
.. .....
70 ....
...
1 ..: ....
i :. - • I
.,., ..; ., ..; .•• .
60
1__.
. ..
I . :
-': , - .1.
• • • ...; : ...,:l...,,, " • • .. .
• 1.. •; ..
.. I:. : ..i
. -

II ;,.. . . -; .
• -

.
i
-r-- ' -I;

23 "
, ,. . . . .:: - ir
..!
u;
...
• ;
: Li
;;
1 .

FREQUENCY (Hz) 1 7: — • • • • .••


11119
1 fl

• 11 it ; . 0 1 ...? . gimp

. 1.
ii i
.
III- •

: Eh ' .
' ..111
V iii I • .


1;I . al li •::
ICY iii,
10 100 lk 10k 100k

FIGURE 2-7. LIMIT FOR CS09


Downloaded from http://www.everyspec.com

MIL-STD-4 61C
?art 2
NOTICE 2 (USAF)
15 October 1987

Frequency (MHz)

* SIN(2nft)

whan,

fPIN (I) s common modr pi


current in amps
f frequency, h m

FIGURE 2-8. LIMIT FOR CS10


Downloaded from http://www.everyspec.com

MIL-STD-461C
Part 2
NOTICE 2 (USAF)
IS O c t o b e r 1967

-. -
0.63 MHz -
d

-. ---
.
I I LIyy 1 11111' 1 l l l r l l I I I I I &

Frequency (MHz)

common mode coblt


current in omps
ftequtqcy, htrn
lime, wcsndr
decay foctor

FIGURE 2-9. LIMIT FOR CS11

7-71
Downloaded from http://www.everyspec.com

MI L-sTD'A~~C
Part 2
"pf!q 4 !l!c$r'
15 October 1987
Downloaded from http://www.everyspec.com

XIL-STD-4 6 l C
?brr. :
NOTICE 2 (USAT)
15 October 1987

i- . . r p !
* jm
.

' . i t , I ,:~,l:~; 1. I..


Downloaded from http://www.everyspec.com

nltSfD-L61C
Part 2
y??: Cf 2 (VSPF;
15 October 1987
Downloaded from http://www.everyspec.com

UIL-STD-G61C
Part i!
NOTICE 2 (USAF)
15 October 1987
Downloaded from http://www.everyspec.com

n1L-STD-LblC
tart 2
NOT i C 5 ? (USAF)
15 October 1987
Downloaded from http://www.everyspec.com

HIL-STD-46lC
Par: ?
NdTICf 2 (USAT)
15 October 19'87
Downloaded from http://www.everyspec.com

MI L-STD-LblC
Part2 .
'sufici z (us1
15 October l!
Downloaded from http://www.everyspec.com

NOTES: A/ waveform equation normalized:


e-(mft)/Q s i n 2nfe where:
f - t e s t frequency (Hz)
t- time ( s e e )
Q- 20+5 quality factor
-2/ "A" is the peak current or v o l t a g e l e v e l shovn i n Flgure 2-18.

FIGURE 2-17. Waveform for CS13.


Downloaded from http://www.everyspec.com

MIL-ST D-461
Pert ?
Norrct 2 (L'
15 OCTOBER
Downloaded from http://www.everyspec.com

Part 3. Equipment and Subsyrtere In8talled


Aboard Spacecraft and Launch Vehicles, Including
k s o c l a t e d Ground Support Equipment ( C l u r A2)
Downloaded from http://www.everyspec.com

Part 3

P a r a g r a p h 1. SCOPE
1.1 Determining requirements

CEO1 ( l i m i t e d a p p l i c a b i l i t y )
CEO1 a p p l i c a b i l i t y
CEOL iirita
AC and DO l a a d s .. .
Interconnecting leads

CEO3
CEO3 a p p l i c a b i l i t y
.CEO3 lMts .
AC and DC l e a d s ' .
Intarconnecting leads ,

CEO6 ( l i m i t e d a p p l i c a b i i i t y )
CEO6 a p p l i c a b i l i t y
Cg06 limits
Receivere
Traneaitterci (key-up and standby)
T r a m n i t t e r m ( k e y - d m mode)

m07
CEO7 a p p l i c a b i l i t y .
(Z07limite .
Cs0l ',

CSOl a p p l i c a b i l i t y
CSOl l i m i t s

CSO2
CSO2 a p p l i c a b i l i t y
CSO2 l i r a i t e .
CSO3.( l i m i t e d a p p l i c a b i l i t y )
CSO3 r p p q c a b i l i t y
C903 l i m i t s

CS04 ( l i m i t e d a p p l i c a b i l i t y )
CS04 a p p l i c a b i l i t y '

CS04 l i m i t 8

C s 0 5 (limited applicability)
-5 applfcability
C S 0 5 limits

CS06 .
Cs06 applicability
CS06 limit.

CS07 ( l i m i t e d . a p p l i c a b i l i t y )
CsO7 a p p l i . c a b i l i t y
CS07 liatts .
Regairement 1 .,
Requirement 2

RE01 ( l i m i t e d a p p l i c a b i l i ~ y )
REOl a p p l i c a b i l i t y . .
RgOl.liBit . ...
Downloaded from http://www.everyspec.com

COmmS (Continued)

P ~ r a g r a p h14.2.1 Lrcowband e l e c t r i c f i e l d emir8iow


i4.2.2 Broadband e l e c t t i c 4 b l d emlerlonr
13. 8&03 (limited applicability)
15.1 RE03 a p p l i c a b i l i t y
15.14 h y P O C U ~ ~ ~ ~ I I ~ O
15.1.2 M r Porce and Navy procurement8
15.2 ~ 9 0 3limit
16; U602'
16.1 RW)2 applicability
16.2
16.2.1
16.2.2
--
W2 l i d t e
Pert Z apikea
P a r t If pouer frequency
17. W03
17.1 RSO3 .applicability
17-2 8503 l i d t o

C a t a ~ o r l e rof c i n e s A2 q d p a e n t and rubeyetem


Emission and susceptibility requirersdtr f o r
clasm A2 equipment and eubeyrtem

Lioit f i r CWl nrrro&ld eairsioar


Limit Eor CEO3 asrrouband emiraionr
Limit f o r CEO3 broadbad a i L r i o a r
LiaSt f o r CSOl
-it f o r CS04
Acceptable waverhaper f o r CSO6 and -2
L M t f o r BE01
Limit f o r WOZ narrowband smisrirma
l i m i t f o r RE02 broadbond a n i r r i o m
Downloaded from http://www.everyspec.com

Thie p a r t of MIL-STd6l supplements Part 1 of the standard by d e f i n i p eeieeion and


s u s c e p t i b i l i t y requirement8 and l i m i t r f o r equipmnt and r u b a p t - intended f o r w e aboard
epaeecraft at@ launch vehicles (clan, a), ineludin# aeeociated ground support e q u i p e n t , and
f o r c l a s s A3 equipment and eubsystema proded f o r t h e M r Force.

1.1 Determidug requlremente. Table 3-1 definer, u t e g o r i e r of c U r A2 equipment and


rubryeteam. Table 3 4 1 e h a l l be oeed t o dedetrina tb r e q u i r e m n t s epplieable to c b r A2
eqaipment and s u b s p t a u r . The t a b l e a l s o denotes the paragrapbe wbarein t h e requirements and
limits a r e defined. A '1''entry' i n the t a b l e m a n s the requirement is applicable, and t h e ' .
lMt shall be met usin# the procedure8 i n HU-8tD-462 o r thi apprwed EM Test Plan. A *IL''
e n t r y means the. applicability of t b e requir-nt is limited and is s p e c i f i e d i n t h e corrupood-
i a g appropriate paragraph. When applicable, t h e l i m i t e h a l l be mat w i n g t h e ptocedares i n
ML-8-62 o r t h e approved EllZ T a t Plea. A "T' entry meam t h a t t h e a p p l i c a b i l i t y of the
requireocnt must be detenrlned on a awe-by-case b a r i s and, i f t h e requireaent i s to.be imposed,
it muat be s o r p e c i f i e d i n t h e appropriate procurement document. When required, t h e l i m i t s h a l l
bo met aelng t h e prucedurea i n XIL-8TD-462 o r t h e apprwed EHt Test Plan. Absence of an e n t r y
meanr t h e requirement is not applicable.

TABLE 3-1. Categorice of Clmr A2 equipment awl robayst-.

Category Description

A2a Equipaent i n e t a l l e d on rpacecraft o r bunch vehicle


' AZb Aerospace g o a n d aquipaent required f o r . t h e c h r k o u t
and launch, including e l e c t r o n i c test and support
aquipacnt

AZc Trainers and s i & a t o r a


i
A2d Claee A3 equipaent procuied f o r Air Force use

2. CEO1 (limited a p p l i c a b i l i t y )

2.1 a 1 applicability. Applicatiow ;of this requireaent a r e t o be determined on a


ca8crby-case' baris. 1Jhen requited, CEO1 i r :applicable m l y f o r
' narrowband emissionr b e t m e n
30 Ba and' 15 lrRa e n AC .and DC leade,. vhicb obtain power from o r provide power t o other '
equipment o r eubsystew. The requireaant i q not applicable f o r i n t e r w a n e c t i a g l e a d r unless
otherwise r p e c i f i e d ky t h e Comaand o r agenw concarned.

2.2.1 AC. and .M: leedr. Electromegnetic e m l s e i o w ~ e h a l not


l appear on AC and DC l+ds i n
excme of -the valuer a8 rho? on Figure 3-1. The limits e h a l l be lpet whea w u r e d with a n ,
ef f e c t i v e .bandwidth not exceeding t h e primary power fr,equency plum 20%of the 'pa-t frequrrncy
f o r AC power lea& o r 75 Br f o r DC. power .leadre

2i2.2. Interconnecting leads. If compliance with t h i r requireaent i r requfred f o r


intercbonecting leada, limits e h a l l be developed on a tlree-by-care baeis considering the
intentional trammission, i t r dpecified power level,, neceeaary i u f o t r a t i m banduidth, and
puloe rim time, Such l l d t r m n t be approved by t h e o r agency concerned.

3.1 CEO3 a p p l i c ~ b i l i t e . This requirewent ie' applicable f o r AC and DC l a i d s , which o b t a i n


pouer from o t h e r rourcee o r provide pokr t o o t h e r equipment and subeyetems. The requirement
is not a p p l i c a b l e f o r interconnecting le.dr,.unlera otherwire specified by t h e C-nd or
ageucy . concerned.

3.2.1 AC and DC l e a . K l e c t r m a p e t $ c d s a i o m e h a l l not appear orr AC and DC leads i n


excess of t h e value8 am shown on Figurer 3-2 and 3-3 for-narrovband and broadband cnierionr{
reepectively. Conducted rdtehirrg spike ed)taiona (including OU/OPW - i t c h i n g ) on AC and DC
power leads e h a l l meet t h e rcquiremente of CB07.
Downloaded from http://www.everyspec.com

TABLE 3-11. EMISSKIN AND SUSCEPTIBILITY REQUIREMENTS FOR CLASS


A2 EQUIPMENT AND SUBSYSTEMS
.

CSOl Y T Y Y . 6 34
CSOZ Y Y Y . Y 7
CS03 . Y, Y, YL 8
CSW y, y, YL 9 3-5
CSOb YL y, YL 10
CS06 Y Y Y Y 11 3-6
CS07 VL YL YL 12

RE01 7 T 13 3-7
RE02 Y Y Y Y 14 3-8. 3-9
R€03 YL YL 7 15

RSO2 Y Y Y Y 16 36
RS03 Y Y Y Y 17
Downloaded from http://www.everyspec.com

, 3.22 ~ntercoanectinglead8. If compliance e t h tNr requitelrant la required Lor


interwnnectiag leads, limitr rho11 be developed on a' c a i p - b m e baris coneiderlag t b
intentional tranedrrion, i t e specified power level, yceerary i n f o t l ~ t i o abandwidth, and
polre r i s e tine. Such l i m i t s nort be approved by tho ~otP;and or agency concerned..
4. CEO6 (limited w p l l c a b l p t ~ )

4.1 &6 applicability. Thir requi-nt ie applicable f o r t b r e e q u i w n t . and rub-


r y r t e m with ante- lea& or thoea derigned t o be 9 ~ e C t e dt o aatennar. 'The tranrmttter
(Lepdam mode), hamonies and a ~ i o o es d s r i o n ' p r t i o n r i of thie requirement a t e not
applicable f o r equipment and rubeyetea procured' roiely 'for Amy me, when any bf the
following coad$tioas exlrt: (a) t h n s d t t e r paver e x d o ' 5 W a m r q e , (b) the fundamental
frequency of the test sample exceedi.l.24 Ollr, (c) tha"teat rcmple'r antenna is an integral
part of the transmitter aod cannot 'kr+placed by a w i t a b l e duang load, o r (d) for equipmnt
a d eubeptema with waveguide t r a n r d s r i o n liner and operating b a l m 1.24 Glb. For case6
(a) through (d) use 1803. The Erequeicy range of t N e r&ireuent is dependent on the
operating f requancy of the t e s t sample ' (eee H I L w 6 2 ) t ! The. transmitter (key4am)
portion of t h i e requirement is dot applicable within 'either the t e a t raaple'r decerrary
+
.bandwidth o r 5 percent of tha ' f u n d a e t a l frequency. : ' ;

4.2 CB06 limit?. . hxlucted'e+rriaae i n &re of the values given i n 4.2.1 through
4.2.3 rhall not appear a t the t a t rampletr antenna terminate.

b, Broadband emirsiqDs: 40 dB ~V/Utlt

4.2.2 Transmittem (key-up and rtandbyl.

a. Narrowband d n l i o n e : 34 dB .pV

4.2.3 T r a a r d t t e m (key-down soda). H q r a n i a , except the second and third, and a11
The r e c o d and third harrwicu ehall be ruppreard by: 50 + 10 log P (where P peak power,
in watta, at the fundamental) o r 80 dB. whichwht requires leer ruppreorion.
-
other rpurioor d e r i o n e r b a l l hwe peak powera 80 dB down from the pouer a t t h e fuodanantal.

5.1 a 0 7 applicsbilitr. requirement L applicable fox the following type# of l e d r :


'hi&
AC o r DC leads which obtain power from or provide paver t o other equipmeat or rubaptam;
502 CB07 limits. Conducted rwitchiag spikes of leer than 50 d c r o r a w n d r i n duration
rhall aot exceed the O o l l a r l ~ &'ae 'applicable:
a: AC leads: + 50 parcent 00 nomitul r q t mean square (rm)voltage.
..
b. DC leads: + 50 ~ e r c e n t ,-!SO pmcent of nolainal l i n e voltage.
Conducted switching spikes equal t o or greater than 50 dcroeecoodr i n duration shall a e r
the transient requiremntr a r r p a c i f i d i n the individual'equip.enk or rubiptem rpecificr-
tiom. Spike duration i r tba tim interval khraa the SOX amplitode point on the tc-tent
lead* edge and the 50% amplitude point on tho t r a n s i e t t r a i l i n g edge; high Crspuency
ringing ruperimpoeed on the pulse l e d i h g or t r a i l i n g edges rbould be ignored.

6.1 CSOl applicability. Tbie requireosnt is applicable to equiprent a d r u b a y o t a


AC and DC pavar b a d e , including gram& and w u t r a t which are not grounded internally t o
the equipment or rubepter. The requir-nt i n not applicable within 5 parcent of the+
power frequency(iee). For Haq 'proeuraaantr, this requirement may be deleted fox AC l d r .
with the approval of the Comumd o r agency concerned, i f no circuit within the equipment or
ryrtem i r sore eenritive than 100 DV.
Downloaded from http://www.everyspec.com

6.2 CSOl l i d t r . The tert a ~ e p l er h a l l . a o t exhibit any malfmction, dagradatiua of


perfomawe, o r d e t i s r i o n f ram rpecified indicationr, beyond t h e toletancar indicated i n the
individual equipoant o r e u b y r t c n ,epicit'ication, uheh rubjected t o electroragoetic energy
injected onto i t r power l e d 8 lmr than o r eqorl t o the valuer on Pigute W. Tha r e q d r c o a n t
i e a l r o met under the followfng condition: when t h r powar r o u r w epecif1.d i n MIL--810-462,
d j u r t e d t o d i e r i p a t e 50 watt8 i n a 0.5 ohm load, cannot develop t h e required w l t r g e a t
t h e t e r t a m p l e power input t e r m i n a t , and the test a m p l e i r not aueceptible t o the output
of t b e r i g n a l eource.

7.1 CSO2 a p p l i c a b i l i t ~ . Rrir requirement id applicable t o equipment and r u b o y r t a AC


and M: power leadr, including groundr and neutral6 which a r e not grounded i o t a r n a l l y t o the
e q u i p a n t o r rutmyatem.
7.2 C802~liPritr. The t e s t rample a h a l l not M i b i t any malfunctioa, degradation of
performance, o r deviation from i p e c i t i c d indicationr, beyond the tolerancer indicated i n t h e
individual equipment o r rubryetea epecification, when r u b j e c t d t o 1 v o l t f m i 5O-oha oo~rtee*
The t e a t r i g a a l r h a l l be applied d i r e c t l y t o the equipment itaplrt t e d l m l r , not twough t h e t e a t
mmpla's power l i n e cord. 'Ehe r e q u i t e e a t Lr alao met under tbm follouing conbitLon: &en a
l-watt rource of 50 ohm impedance cannot develop t h e required voltage a t t h e twt rample p m r
input termfnala, and t h e teat eaaple 10 not rurceptible t o the output of the r i g n a l aource.
8 CS03 ( l t i t e d applicability)

8.1 W 3 a ~ l i c a b i l i t y , rhir requirorent i r applicable t o receiving equipment and


ruboyrteor, ouch a r mceiverr, PF amplifierr, t r a n r c e i w r a , and the like. The applicable
frequency raage of thin requirement i r dependant oo t h e operating frequency of t h e t e r t
aample a r specified i a M L - m 6 2 . r o r A m y q u i p l r r n t and a u k p t e m s , t h e r e q u i r e r a t L
applicable only when a p e d f i e a l l y called out i n the procurerent doasmentatlon.

8.2 ~ 9 0 3limitr.
' The t e a t rample r h a l l not e s h i b i t any i n t e r o d u l a t i o n productr from two
rQadr, beyond tboae permitted i n tho individual equipment o r rubayatcr e p e d f i c a t i o a , *an:
a. S i g u a l gonurator 11 is s e t 66 dB above t h e l e v a l required t o obtain t h e
standard reference output, a8 specified i n WIL-STD-462; except t h a t vben f 1
i a i n the frequency range of e i t h e r 200 t o 400 UUx o r 2 t o 25 m, the
generator output r h a l l k 80 dB abwa t h e rateronce l e v e l , but t h e output of
r i g n a l generator 11 r h a l l not exceed 10 dBm.

b. S i g n a l generator 12 is net 66 dB above t h e l e v e l required t o obtain the


ataadard referenee output, an. e p e c i f i d i n MIL-STD-462, but t h e generator
output l e v e l a h a l l not exceed a power l e v a l of 10 dBm.
9. CS04 (limited a p p l i c a b i l i t y )

9.1 CS04 applicability. Thie requirement i r appUcable t o r e c e i v i r y equfpeent and


rutmyrtaw, much a r r a c a i v t r r , RP amplifiere, tranrcetiverr, and t h e like. The applicable
frequency tango of thir requirement i r dependent oo the o w r a t i n g frequency of the test
a m p l e , aa rpacified i n HILSTD-462. For Army equipment and eukyatea#, t h e raquiremsnt is
applicable only when a p e c i f i e a l l y c a l l e d o u t i n the procurament docurentation.

9.2 m04 LUtr. The t e r t a m p l e a h a l l not e x h i b i t any undoaired reaponre whcn


subjected t o t h e test r i g n a l ahown on Figure 3-5.

10.1 CS05 applicability. 12110 requirement i r applicable t o receiviag equipment and


rubsyetelu, a d a r receioerr, RF amplitiarr, tranr&iverr, and t h e like. The applicable
frequency r a m of t h i r . r e q d t u e n t i n dependant on t h e operating frequency of t h e t w t
s u p l a aa specified i n ML-STD-462. For A m quipmant and s u b s y a t e r , ttm, r c p u i r m a n t i r
applicable only when r p e c i f i c a l l y called out i n the p r o c u r d a n t docunentrtioa.
10.2 CSO5 l i r i t a . The tut ramp10 a h a l l not axhibit, due t o croeo modulation, any
mrlfunctioa, degradation of perfamanee, o r deviation Croa r p e c i f i e d iadicatioru, beyond t h e
t o l e r a n c u indicated i n the individual equipmnt o r aubeye~terr p e d f i c a t i o n , whaa rubjected t o
t h e folloving f r o n r i g n a l geasrator 1 2 : a rlgnal 66 dB above t h e l e v e l required t o obtafn t h e
rtandard reference output, as apacffied i n H U - S I D Z D - ~ ~ but
~ , not t o exceed a powr output l e v e l
of 10 dB&
Downloaded from http://www.everyspec.com

11.1 CS06 applicability. Thie requirerant is applicable t o equipoant and subsyetem AC


and DC power leade, includiag grouada and n e u t r a h whicbare not grounded i n t e r n a l l y t o t h e
equipment o r eubyetea.
11.2 CS06 l i d t r . The t e s t ram& e h a l l not exhibtt any aalfunctioa, d e g r d a t i o n of
performance, o r deviation from specified indimtione, beyond t h e tolerances indicated i n t h e
individual equipment o r eabeyetem epeciEicatioa, when t h e - t a t epikes having the waveform
shorn on Figure 3-6 a r e applied t o the AC and DC power Input leads f o r a period of not leee
thaa 1 a i n u t e a t each phaee pbeition, and f o r a t o t a l t e e t period not exceeding 15 -tee in
duration ( i n l i e u of the values i n KIL--62). The value8 of E() aud t~ a r e given below.
U c h spike e h a l l b eupari.poeed o n the p o v c r l i n e ' v o l t ~ ewaveform.
a. Spike # l (All Servlcee) ~1 = 200 Volts; e l 10 microeecondr
. . + 20%.
b. Spike I 2 ( A i r Force and Navy) B2 - 200 Volts; t 2 = 0.15 microeeconde + 20%.

12. CSU7 ( l i a t t e d applicability) . .

12.1 CS07 applicability. This requirement.ie appll&ble f o r receiving equipmefit and .


eubeyetema whlch ~ r t i t i c eequelch circuits.
. 12.2 CS07 limits.
12.2.1 Requirement 1. The equeLcb c i r c u i t s e h a l l ,not open when the output of a S k h m
impedanca impulse generator, set a t 90 dB u V / K l k , k applied and matched t o the input terminale
of the t e s t eample.
12.2.2 Requirerent 2. The squelch c i r c u i t e h a l l not open when two signals a r e applied
a t t h e input of the tart eample. One signal r h a l l ba an uclaodulated RF eignal a t the receiver
tuned frequency, whose amplitude i e two-thirds of tha UP voltage ueed t o adjust the equalch
threehold. The second e i g a l e h a l l be an impulee signal of 50 dB ~V/HBx. .
13. RE01 (limited applicability)
13.1 RE01 applicability. Applimtiorm of t h i s requirement a r e t o be determined oa a
we-bp-care basis. when required, BBOl i r applicable f o r radiated e d a e i o ~from equipmeat
and eubeystcnr, cablms (includiag control, pulse, IF, power, and antennae traaoaieelon liw)
and interconnecting wiring of the t e e t sample. The requirement applier a t the fundanental
frequencier and all epurioue d 8 S i 0 M B including harmonica, but doee not apply t o radiation
f r a r antennae.
13.2 RE01 liait. WgnetLc f i e l d d e e i o n e e h a l l not be radiated i n excess of the lavcrlr
shown on Figure 3-7.

14.1 RE02 applicability. This requirement is applicable f o r radiated erissiona from


equipment nad subyeteam, cablee (including control, pulre, IF, power, and antermae trans-
r i e r i o a lines) and intercoaaectil3g wiring of the test sample; f o r narrowband, i t appliea a t
t h e fundamental frequeucies and a l l s p u r i w d s i o a s , 'including 'harmonica, but does not
apply t o radiation From antennas. Thie requirement is:applicable f o r broadband emirsiona
froah 14 kHz t o 1 GB+ and f o r aarroybaad e d s s i o n r from.14 Ulr t o 10 CRr.
, .
. 14.2 RE02 limits. B-field e m i r e i o ~shall not be rdLated ia excere of t h e e given
i n 14.2.1 and 14.2.2. Above 30 MHz, the l i m i t r s h a l l be wt f o r both horizontally and
v e r t i c a l l y polarized waves.
14.2.1 Narrowband e l e c t r i c f i e l d a i e s i o a a . Uarrowba~ldE-fiald eaiseiona s h a l l not
be radiated i n excess of the limit curve shown on N g u r e 3-8 a t the reqaired t e s t distance,
. ae s p t o i f i e d i n Wa-Sm-462.

14.2.2 Broadband e l e c t r i c f i e l d d r r i o a a . Broadband E-field e d a s i o n a f r m a l l equipment


and subrystame, including radiated switching t r a m i e n t s resulting from (1) automatic cycling of
electronic o r e l e c t r i c a l switching c i r c u i t r y , (2) actuation of p h - t o - t a l k mechanirae (that is,
keying oE trannaittera), or (3) manual aaitching e h a l l lrgt be radiated in axceaa oP..the applicabla
Umit curve ahom on Figure 3-9 a t the required t a ~ dietances, t M specified i n MIL-STD-462.
Downloaded from http://www.everyspec.com

15. BE03 ( l i d t e d a p p l i c a b i l i t y )

15.1 a 0 3 applicability. Thle requirarsnt i e applicirble f o r thoee equipmnt and


oubmyetema with antenna leads o r t h e deeigned t o be connected t o antennas. The f r q u e n c y
range of t h i s requirement 10dependent on t h e operating frequency of the t e a t sample (eee
WL-STD-462). The requiremint is not applicable within e i t h e r t h e test e ~ p l e ' eneceseaty
+
bandwidth o r 5 percent of t h e f u n d d e n t a l frequency.

15.1.1 Army procuremento. M a requirment i e applicable f o r tranemitting equipmot


and eubayeters procured r o l e l y f o r Amy use when any of the followtag conditiolu exist:
(a) t r m e m i t t e r power exceeda 5 kW average, ( b ) t h e fundamental freqwdcy of the t e e t a m p l e
axcecde 1.24 CHt, (c) t h e t e a t enmplela antenna is an i n t e g r a l part of the transmitter and
cannot be replaced by a .uitable durJ load, o r (d) f o r equipacnt and sukprtelrr v i t h wave-
guide tranrmiesion l i n a s and operating below 1.24 GMz.
15.1.2 Air Force and Navy procurtnante. Thio r e q u i r e r n t is applicable, v i t h t h e
approve1 of the procuring a c t l v l t y , when the epuriou. emfssiona and hamonice a n n o t be
determined m i n g t h e proceduree i n -6.

15.2 RE03 limit. Harmonica, except the second and t h l r d , and a11 other s p u r i m e
eatreionn e b l l have peak powers 80 dB down from t h e
a d t h i r d harmonics a h a l l be e u p p r e s d by: 50 + 10
a t the fundmental) o r 80 dB, d c b e v e r requires lea.
-
pover a t the fundamntal. The eewnd
log P (where P peak power, i n watt@,
auppreeeion.

16.1 R602 applicability. Part8 I and I1 a r e applicable f o r a l l Do0 a c t i v i t i e e .

-
16.2.1 Part I avikea. The test .ample o h a l l not exhibit any malfunction, degrada-
t i o n of performance, o r davfation f r o a epecified indicatiooa, bepnd the tolerancee indicated
i n the individual equipmnt o r oubyoteu epecification, vhen eubjected t o the t e e t spikes
having the waveform ohown on Figure 3-6. The v a l u u of E() and to
a r e given belov:
a. Spike I 1 ( A l l Services) El - 200 Voltr; t l = 10 microeecoade 2 20%.

b. Spike I2 (Alr Force sad navy)


-
16.2.2 Part I1 p o ~ frequmtcy.
r
112 - 200 Volts; t 2 - 0.15 microeeconda
The t e s t eampla e h a l l not exhibit any malfunction,
2 20%.

degradation of perforraoce, o r deviation from specified i n d i c a t t o m , beyond t h e tolerances


indicated i n t h e individual equipment o r .ubsyeterr r p e c i f i u t i o n , when 20 amparee a m applied
t o the t a t Vire a t tha power frequency(ies) of the t e s t ample.

17.1 BS03 applicability. Tbie reqdr-nt i e applicable f o r a l l equipwlrt and nub-


ayet- behean 14 kEz and 10 GHr. Above 10 Ollz, thin requirement appliea only a t a l l
intentionally generated f r o q w n c i u of any ham emitter on the epacecraft o r launch vebLclo.
For Air Force procuremento, t h l e requirement is not applicable above 10 GHz, unleee otberwiae
rebuired bp the procuring a c t i v i t y .
17.2 W 3 limits. The t e a t a m p l e a b a l l not exhibit m y permanent malfunction,
degradation of perforrpnce, o r devlatloo from apeclfied indications, beyond t h e t o l e r a n w e
indicated I n the individual e q u i p a n t o r eubaystem e p e c l f i c a t i w , when eubjected t o t h e
radiated e l e c t r i c field. (B) l e a s than o r equal t o thore epecified herein. Above 30 nBr,
thi requirammt e b a l l be met f o r both horisont.lly and v e r t i c a l l y polarized waver; c i r c u l a r
polarizad vavea e r e a l s o acceptable. Appropriate w n s i d e r a t l o n a h a l l be given t o t h e
operational radiated electroragnetic mviro-t from both friendly and h o a t i l e emitters
which an equipneat o r .ub.peta may encounter during its l i f e cycle. Applicable portionr
of WIkiIDBK-235 a h a l l ba wed t o datemine the anticipated environment. Ao a mini-, the
follawiag levela a ply. I f l e v e l 8 eubatantially higher than thoae given hereia a r e specified,
oodificatfom t o tRe p r o c d u r a s in HIL-STD-462 m y be required. such urdificetionr a r e t o
be described i n t h e 6MI Teet Plan.
Frequency Ranm
14 kHz t o 30 MI2
30 MHz t o 10 GBa
Above 10 GHt
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com

Limit

- .
-
fg Bcteiver tuned frepueney o r band center for amplifier8

fl Lbweat tunable frequency of receiver band i n o r e o r the l o v e r t frequency


of amplifier parrband.
f2 ' - Ei8iier t t u m b l e frequency .of receiver band i n uee o r the highert f rtquency

-
of amplifier p a r e b a d .
W b a d d d t h betveen the 80 dB point8 of 'the receiver relecti*ity curve a8 defined
i n the t e a t rample'r technical requirementr o r the control plan;

1. The lipit a t A is 80 dB a b w e the input, l e v e l required t o produce the standard


reference outpot. (This l i m i t s h a l l not be ueed f o r n p l i f i e r r )
2. The limit a t 1 shall ba met a8 followr:
a. Receivere: 0 dlm applied d i r e c t l y t o the receiver input t e d c l a l r .
b. h p l i f i e r r : The l i m i t r b a l l be a r rpecified i n the t e a t u r p l e l r technical
requirement o r control plan. If no limit i r defined i n th above documentr,
the 0 dBm value r h a l l k ueed.

FIGURE 3-5. LIMIT FOR CS04


Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com

Part 4. Bquipaent and Subryatetr tnatalled i n


Ground P a c i l i t i e a (Pixed and Hobile, Including
Tracked and Wheeled Vehfelee) (Clabe A3)
Downloaded from http://www.everyspec.com

Part 4

Paragraph 1. SCOPU
1.1 Determining requiremento

Cgol (limfted a p p l i c a b i l t t y )
CEO1 a p p l i c a b il i t y
DC and interconnecting leade
AC leade
CBOl linits
DC leade
(\C leade
Interconnectiag lea&
Army p r o c u r c p a t a
Intarconnecting control leade
Interconnecting eignal leads
Wavy pmcutelPant8
Conuected o u t e r e h i e l d and twisted p r i m together
Dirconnected o u t e r e h l e l d and.twinted paire eepntrted

CEO3
CEO3 a p p l i c a b l l i t y
a 0 3 limit0
oC leade
AC leade
Army procurements
Navy procurementn
Znterconaecting lea&
Amy procurement8
Interconnecting control l o d e .
Interconaecting mignal lead8
Wavy procutemnte
Connected o u t e r e h i e l d and' twisted pel r s together
Discoaaected o u t e r r h t e l d and twirrted p a i r e eepareted

W 6 (limited a p p l i c a b t l i t y )
CEO6 a p p l i c a b i l i t y
a 0 6 limits
Receivere
T r a ~ d t t e r e(key-up and standby)
'Pransmttterr ( k e y d o m mode)

C907
CEO7 a p p l i c a b i l i t y
CEO7 l i m i t e

CsOl ( l i d t e d a p p l l c a b i l i t y )
CSOl a p p l i c a b i l i t y
CSOl l i d t e

cso2
CSO2 a p p l i c a b i l i t y
CSO2. l i m i t 8

CS03 (ltmited a p p l i c a b i l i t y )
CS03 applFcabFlity
CS03 l i u d t e

CS04 ( l i m i t e d a p p l i c a b i l i t y )
CS04 a p p l i c a b i l i t y
CSO4 limits

CS05 (limtted a p p l i c a b i U t y )
CS05 a p p l i c a b i l i t y
CS05 l i m i t @
Downloaded from http://www.everyspec.com

Rre 6

IS. CS1 L ( l i m i t e d a p p l i c a b i l i t y )
1541 CSI I applicabf.lSty
15-2 CVll l i m i c
RE01 ( l i d t e d a p p t i c s b t l L t y )
.RKOl a p p l i c a b i l t t g
RE01 lidt

Narrwband electrlc elall eet.eion,


Broodband e l e c t r i c f i e l d e d e n l o n e

Ilm3 ( l i d t e d a p p l i c a b i l i t y )
RE03 a p p l i c a b i l i t y
Army p r o c u r e m c 8
Navy procurement8
RW3 ltdt

US01 ( l i d r e d a p p l i c n b i l i t y )
BsOl a p p l i c a b i l i t y
RSOl l i m i t
-2
-2
Part
Part
--
applicability
Z .pikes
11 pawr frequency
8902
Part
Part
--
lidts
I ~pikea
I1 potRr frequency

BS03
RSO3 a p p l i c a b i l i t y
BS03 limits
BSOS ( l i d t e d a p p l i c a b i l i t y )
W 5 applicability
BSOS l i m i t :

Bpiarlon and e w c e p t i b i l i t y requiremonte f o r


c l a s s A 3 equipaene and euboptema
Downloaded from http://www.everyspec.com

MGSTD461C

COmBIRB (Continued)

Part 4

L L .t. for CEO1 M! a d interconnecting laadr


Lia f o r CEO1 AC Ieda
L L .t f o r CB03 narrowbmtd omirriarrr DC and
int !rconaectiw l a i r a d AC l e d # (m)
Iln .t for CE03 b r o d b n d adasion# D C . m d
i n t rreonnecting leadr' a d AC k d a (Arqy)
.Lip It for W3 narrowband aderionr AC leads
(Ha 'Y o w )
Lim Lt f o r CEO3 b r o d b n d d r r i o w AC llrdr
(b 'Y O " ~ Y )
ti..t for CSOl
Lil .t f o r CSO4
Ace ~ptablewayerimp.8 f o r C306 and 8802
Li. i t for CSO9
L h :t for a 1 0
LL L t f o r CS11
Li. !t f o r RE01
lirit tor. -2 aarrouband a d r r i o n r
Limit for UEO2 broedband emirrionm
u t for RSOl
Wt f o r BB05
Downloaded from http://www.everyspec.com

This part of ML-STD-461 supplements P a r t 1 of t h e standard by deLLning emiesLon and


s u s c e p t i b i l i t y requireoents and limits f o r equipment and s u b p t e e s intended f o r we i n ground
fixed and r o b i l e facilities, including tracked and wheeled vehLcles (Clara A3). Navy require-
meats f o r ground rapport equipment wed f o r checkout and launch of a i r c r a f t , spacecraft, and
lauoch vehicles e r e contained i n P a r t s 2 aod 3 of MIL-9-61 and should be t a i l o r e d a s
neceeesry. P a r t 4 is not applicable f o r A i r Fore8 procurements; r e f e r t o P a r t s 2 and 3.

1.1 D e t e r d o i n g requirementr. Table 4-1 shall ba ured t o deternine t h e s p e c i f i c require-


m t s f o r claee A3 equipment and subsystem. The t a b l e a l e o deootes t h e paragraphs wherein
the requirements and l i m i t s a r e defined. A "Y' entry i n t h e t a b l e means t h e requirement is
applicable, and t h e l i m i t s h a l l be rmt using t h e procedures i n ML-STD-462 o r t h e approved ENI
Teat Plan. A "YLU e n t r y mesae t h e a p p l i c a b i l i t y of the requiremint is lbitd and i s s p a c i f i e d
i n t h e appropriate correepoodiog paragraph. When applicable, t h e l i m i t s h a l l be met w i n g t h e
procedures i n UIL-Sllb462 o r t h e approved El(I Test Plan. A "T" e n t r y meam t h a t t h e a p p l i c a b i l i t y
of the requiremmt must be detemined on a case-bycase b a s i s and, i f t h e requirement is t o be
imposed, i t must be ao s p e c i f i e d i n t h e appropriate procurement document. When required, t h e
1-t shall ba met usillg t h e procedures i n MIL-STD462 o r t h e appraved M I Test Plan. Absence
of s o e n t r y means t h e requirement is not applicable. For procurements of subrystew, such a s
radar, BW surveillance, aod t h e l i k e , comprised of iodividual equipment l i s t e d i n Table 4-1,
t h e applicable epiaaioa and r u s c e p t i b i l i t y requireaents f o r the s u b y s t e m s h a l l be t a i l o r e d by
the procuring actLvity based on t h e r e q u i r a e n t s of t h e individual equipment.
2. C g O l (limited a p p l i c a b i l i t y )

2.1 CEO1 a p p l i c a b i l i t y . This r e q u i r e m n t is applicable f o r a l t e r n a t i n g c u r r e n t (AC) and


dLrect currant (DC) leads, which obtain pover from o t h e r sources o r provide parar t o o t h e r q u i p
a m t o r subsystems; grounds o r neutrals, which are not grounded t n t e r n a l l y t o t h e subayrtem o r
equipment being rpseured; and interconnecting c o n t r o l leads, which provide AC a d DC pomr from
o r t o t b e t e s t sample. The requirement 1s not applicable f o r interconnectiog s i g n a l leads such
a s clock, IF, audio, f i r i n g , d i g i t a l , PP, and t h e l i k e , unless otherwise s p e c i f i e d by t h e C a v n d
o r agency concerned. For Army equiplwnt or subsystem t h e requirement is applicable only d e n
s p e c i f i c a l l y c a l l e d out i n the procurement docurnotation.

2.1.1 DC and interconnecting leads. T h h requirement is applicable f o r narrwband emisslolu


f r o a 30 ifz and 15 kHz.

2.1.2 AC leads. The requirement is applicable f o r equipment a d subysteme procur.ed f o r


Navy use. h i s requirement is applicable f o r oarrowband e r l r s i o a a from t h e power frequency(ies)
of t h e t e s t sample t o 15 kk. Other applications oad l i m i t s f o r t h i s requirement a r e t o be
determioed and s p e c i f i e d on a caee-by-caee basis.

2.2.1 DC leads. ElectromagneLic a r i s s i o w shall not appear on DC l a d s k e x m a of the


valuea s h w n on t h e applicable curve on Figure 4-1. The l i m i t s s h a l l be met when measured v i t h
an e f f e c t i v e bandwidth not exceeding 75 Hz.
2.2.2 AC leads. Blectromagnetic emissioae shall not appear on AC leads i n excess df t h e ,

values shown on t h e applicable l i m i t l i a e on Figure 4-2. h e l i m i t s s h a l l be wt when ~ u r e d

.
v i t h an e f f e c t i v e bandwidth not exceeding the primary power frequency plus 20% of t h e p r i m r y
power f requeacy
2.2.3 Interconnecting leads.

2.2.3.1 Amy procurements.


2.2.3.1.1 I o t i r c o n n e c t i control leads. Illektromegnetic d s s i o s~h a l l not appear on
i n t e r c o n m e t i n g w r r o l laads% .icus of the v a l u u shown on t b a applicable cum on Figure 4-1.
The limits sball be met when meaeured with an e f f e c t i v e bandwidth not e x ~ e e d i n g , t h eprimary p o F r
frequency plus 20% of t h e primary pomr frequancy f o r AC leads o r 75 Wo Lor DC leads.

2.2.3.1.2 Interconnecting s i g n a l leads. I f compliance v i t h t h i s requirement is required


f 6 r signal leads, l i m i t s s h a l l be developed on a caee-by-case basis coosidering t h e i n t e n t i o n a l
t r a n m i s s i o n , its r p e d f i e d pover l e v e l , neeweary F n f o r u l i o n bandwidth, and pulse r i s e the.
Such limit8 must be approved by t h e C-ad o r agency concerned.
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com

2.2.3.2 ' k v y procurements.

2.2.3.2.1. Coonected outer ahielda and twieted p a i r s together. For interconnecting


control and e i g n a l leads haviog the outer rbieLd connected, and f o r t v i a t e d p a i m with t h e
paira together, electromagnetic emissions a h a l l not appear on t h e lead8 i n exceaa of the
valuea ahown on t h e applicable curve oo Figure 4-1.

2.2.3.2.2 Maconnected outer r h i e l d and twlrted p a i r a aeparated. For' i n t e r c o o k t i n g


control and a i g n a l lea& having t h e outer a h i e l d dirconnected, aod For twiated pain having
t h s pairr aeparated, t h e l i m i t a r h a l l be developad on a carcrby-caae b u i r , c o n r i d e r i a g the
intentional transmiasion, i t a apecilied power l e v e l , neceaaary i n f o r m t i o n bandvidth, and
pulae r i a e time. Such limit. muat be approved by t h e Command o r agency concerned.

3.1 CEO3 a p p l i c a b i l i t ~ Thia requirement La applicable f o r t h e following type8 of leada:


AC and DC l a d e , which obtain power from other eourcea o r provide pouer t o other equipment,
distribution panela, o r aubeystema; grounda o r n e u t r a l s , r h i c h are not grounded I n t e r n a l l y t o
the aubryatem o r equipment b e i w measured; a d interconnecting c o n t r o l leado, uhich provide AC
a d DC power from or t o t h e t e a t a b p l e . The requirement i r not applicable f o r intetcoaaecting
sigoal leada ouch aa a clock, IF, audio, t i r i n g , d i s i t a l , OF, and t h e l i k e , unleea otherviae
apecified by t h e C o l u n d o r agency concerned. Por Amy procurerantr, the r e q u i r e m a t i a appli-
cable using t h e Line Impedance S t a b i l i z a t i o n Network, aa described i o MIL-STD-462.

3.2.1 DC la&. Blectromagnetic eaiaaionr aha11 not appear on DC l e d 8 i n excara of


the valuaa ahom on t h e applicable curve on Figurer 4-3 and 4-4 f o r currowband and broadband
e m i a a i o ~ , reupectively.
3.2.2 AC leada.

3.2.2.1 Army procurementa. B l e c t r n u g n e t i c eaiaaiona a h d l not appear on.AC t d a i n


exceaa of t h e valuea ahoun on Pigurea 4-3 and 4-4 f o r narrowband and broadband emfaaiow,
respectively.

3.2.2.2 Uavy procureaenta. H l e c t r ~ n e t i cs n i r r i o n e a h a l l not appear oo AC Leada i o


excaea of the valuea uhom on Figure8 4-5 and 4-6 Lor m r r w b a n d and broadband emiaaiona,
rcrpectively.

3.2.3 Interconoacting leada.

3.2.3.1 Army procurements.

3.2.3.1.l Interconnecting cootrol lea&. E l e c t r a a g n e t i c emfarionr a h a l l not appear on


intercmoacting c o n t r o l lea& i n exceua of t h e values shorn on t h e applicsbLe curve on Figurer
4-3 a d 4-4 f o r narrowband and broadband e d a a i o n s , respectively.
3.2.3.1.2 Interconnecting aignal leada. I f collpllaoce with t h i n r e q u i r e m n t i r required
f o r siwl lead., l i m i t s a h a l l be developed on a care-by-caae beria conaidering t h e i n t e n t i o n a l
tran.rl4rionb itr apecified powr l e v e l , neceaaacy informatioo baodeidth, m d pulee r i a e the.
Such l i m i t . muat ba appcwed by the Comaad o r agency concerned.
3.2.3.2 1 % procurements.
~

3.2.3.2.1 Connected outer ahielda and t w b t e d p a i m together. l o r ioterconnecting


control and r i p e l lea& having the outer a b i e l d corme.cted, and f o r M a t e d prim with t h e
p a i m together. e l e c t r ~ n e t i emissions
c s h e l l not *war oa t h e leada I n exceaa. of t h e
kluu r i m on t h a applicable c u r w on Figurea 4-3 and 4-4 f o r narrowbond and broadband
e d m i o l u , respectively.
3.2.3.2.2 Diaconscted o u t e r ahield and tvirrted paira aeparated. For interconnectiag
control and signal lead8 having t h e o u t e r a b i e l d disconnected, and f o r twisted p a i m having
t h e p.,ira aeparated, the l i m i t a a h a l l be developed on a came-by-cnre b u i a c o n s i d a r i i y t h e
i n t e n t u n a 1 t r a n s d a a i o n , i t s apecified pover level, neceerary information b a d w i d t h , and
pulae r i a e tie. Such limita must be approved by t h e Coluand o r ageacy concerned.
Downloaded from http://www.everyspec.com

4. CEO6 ( l i r d t d a p p l i c a b i l l t y )

4.1 a 0 6 applicability. This requirement is applicable f o r those equipment and r a b r ~ t a m r


with ante& leadr o r t h w e derigned 'to be comected to'antennae. The tranemitter (kegdm
aode), harmnic sad epurioue eaieeion p o r t i o ~of t h i a requirement a r e oot applicable f o r equip-
mint and eubryet- procured oolely f o r Army uee, when any, of the following conditionr 0xi.t:
(a) t r a m d t t e t p m r exceeds 5 kW aveI:age, (b) the fundamntal frequency of the t e a t a m p l e
exceed8 1.24 GI&, (4 t h e t e a t rample'a antenna La an i n t e g r a l part of t h e t r a n s d t t e r a d cannot
ba replaced by a e l l i t a b t duamp load, o r (dl. f o r equipment and subayeteas k i t h waveguide traae-
d e a i o n linen and o p e r a t i q beloy 1.24 GHs. For cases (a) through (d) uee ~ R 0 3 . The frequency
range of thin requirement i e d e w d e n t . on 'the operating. frequency of t h e t e a t sample (eea
~ L G m 6 2 ) . The t r a n e d t t e r ( k e y - d k ) portion .of thin requirement io not applicable w i t v n
+
e i t h e r t h e t a s t sadple'e neceeaerp 'bandwidth o r 5 percent of t h e fuadaaental frequency.

4.2 -6 l i a i t e . Conducted e d r e i o n a i n exccse of t h e value8 given below e h a l l not appear


a t the t e a t eample'e antenna. terrpinals.

4.2.1 Receivers.
a. Narrowband e d r e i o n s : '34 dB PO

4.2.2 Treineritters (keyup 'and e t a d b ~ .


a. Narrowband arieeiona: 34 dB pV

b. Broadband emirelone : 40 dB pV/Wz


4.2.3 W e n a r i r t e r e (key-down d e l . Harmonica, 'crcept the e e c o d cud t h i r d , and a l l othar
-
epurioue emteeions a h a l l ham peek pouare 80 dB down from the power a t the Eundamental. The
eccond and t h i r d harmonica a h a l l be euppreseed by: 50 + 10 log P (where P peak power, i n watts,
a t the fundameatal) o r 80 dB, whichever r q u i r e e l e a s ruppreseion.

5.1 CEO7 applicability. Applicatfona of thin requirement nre t o be determined on a


caoe-by-care berrie f o r Navy procutel#nte f o r the following-type8 oP leads: AC o r M: leade
which obtain p m e r Erom o r p r w i d e power t o other equipment o r e u b y a t e a .
5.2 CEO7 limits. Conducted e d t c h i n g epikes of lean than 50 microeecoodr i n duratioa
a h a l l not exceed t h e Eoll&ng,.ae applicable:

'a. AC leado r & 50 percent of nominal rm voltag&.

b. DC leade: + 5 0 percent, -150 percent of nominal l i n e voltage.

Conducted ewitching epilsee equal t o o t greater than 50 aicroseconde i n duration e h a l l meet t h e


traneient requiremente an epacified i n the individual equipaant o r submystem epeciPtc(rtioa8.
S p i b duration l a the tim i n t e r v a l b e t a t h e 50% amplitude point on the traneient lesdiag
edge and t h e 50% amplitude point on the t r a m l e n t t r a i l i n g edge; high frequency ringing r u p e r
hpoeed on t h e pulee leediug o r t r e i l i n g ' dgm ehould be ignored.
' 6. C901 (limtted applicability)

6.1 CS01 applicability. requirerent i e applicable t o equipmnt and e u b e y e t r M: and


DC power leade, including grounds end neutrals, h i c h a m not pounded i n t e r n a l l y t o the q u i p o a n t
+
o r eubaprtem. The r e q u i r w t i e n'ot applicable within 5 percent of the power frequency(iea).'
For Havy procurcamte, thin r e q u i r w n t mity be 'deleted f o r AC lea&, with t h e approval of t h e
Commnnd o t agency concerned, i f no c i r c a i t within t h e equipment o r eysten 10aore e e a e i t i v e than '
. .
100 mV o r better.
6.2 CSOl limlte. The 'tdet aeopld e h a l l not exhibit any malfunction, degradation Of
performance, o r deviation from e p e d f i e d indicatione; beyond t h e tolerances indicated i n t h e .
.individual equipmat o r rubayetea apacification, ahon eubjected t o elactroaagnetic e n e r n 4njected
oato i t e power leade lee8 then o r equal t o tho valuer on Figure 4-7. The requirement is a l e 0 pat
under t h e f o l l w i n g conditionl h e m the gorrer .eource rpecified i n WIL-STD-462, adjueted t o
d i a e l p a t e 50 watte I n a 0.5 ohm load, cannot develop t h e required voltage a t t h e t e a t e e l e powat
Input termloale, and t h e t e a t eampla.'ie.not eueceptible t o the output of the eignal ewrce.
Downloaded from http://www.everyspec.com

7.1 CSO2 applicability. Thin requireaent i r applicable t o equipment and eubsyrteo AC


and DC power lead., including grouudr and neutrala which a r e not grounded i n t e r n a l l y t o t h e
equipment o r eubeymtem.

7.2 CSO2 l i m l t r . Tbe t e r t a m p l e r b l l not e x h i b i t any olllfunctlon, degrsdstion of


perEormsnce, o r deviation from specified indicationo, beyond the toleraacer indicated i n t h e
individual equipment o r rubeymtem rpecification, when rubjected t o l - v o l t f r a a 50 ohm emrce.
fia t e n t mignal s h a l l be applied d i r e c t l y t o t h e equipmat input t e r r l n a l r , not through t h e '
test srmple'q pover l i n e cord. 'Lhe requirement is a l s o met under t h e following condition:
when s 14stt rource of 50 o h impedance cannot develop the required voltage a t t h e t e s t
sample power input terminale, and t h e t e a t rampla i e not surceptible t o t h e output of .the
rfgnal source.'

8. CS03 (limlted a p p l i c a b i l i t y )

8.1 CS03 a p p l i c a b i l i t y . Zhie requirement is applicable t o receiving e q u l p r n t and


rubsyrtew, such a e receivere, UP amplffietr, transceiverm, and the like. The applicable
frequency range of thlm requirement i r dependent on t h e operating frequency of the t e a t rample,
sr rpecified i n MIL-S'Kj-462. Por Amy equipment and subsyrteos tb requirement i r a p p l i c s b l e
only when r p e c i f i c a l l y c a l l e d out i n t h e procurement documentation.
8.2 CS03 limits. The cent sample a h s l l not e x h i b i t any i n t e ~ d u l a t i o nproduct6 from two
mignalr, beyond thome permitted i n t h e individual equipment o r r u b y r t e o e p e c i f i c a t i o n , uhm:
a Signal generator il is n e t 66 dB above t h e l e v e l requlred t o o b t a i n t h e
standard reference output, a r specified i n UIL-STD-462, except t h a t when f l
i r i n t h e frequency range of a l t h e r 200 t o 400 Mlz o r 2 t o 25 )nit, t h e
generator output e h a l l be 80 dB above the.reference l e v e l , but t h e output
of s i g n a l generator il r h a l l not exceed 10 dBa.

b. Signal generator I 2 is s e t 66 dB above t.he l e v e l required t o obtaln t h e


standard refereace output, sr specified i n UIL-StD-462, but t h e geaerator
output l e v d e h a l l not exceed a porrer l e v e l of 10 d h .

9. CS04 (limited applicability)


9.1 a04 applicability. Thir requirement Is applicable t o receiving equipment and
rubayrtaoa, ouch an receivarr, RE amplifierr, transceivers, and the like. h e applicable
frequency range of t h i n requirement ir dependent on t h e operatlng f r q u e n c y of the t e a t rample,
as rpecified i n UlLSTO-462. For Army e q u i p n t and rubayrters t h e requirement i a applicable
only when r p e c i f l c a l l y called out i n t h e procurement documeatation.

9.2 CS04 l i m l t r . The t e r t remple e h a l l not exhibtt any underired rerponee when rubjected
t o the t e s t s i g n a l r h on Figure 4-8.

10. CS05 (limited a p p l i c a b i l i t y )

10.1 CSO5 applicability. Thin r q u i r e a e n t i e applicable t o receiviog equipment and


rubSystem, ouch a s recaivers, RP amplifier#, transbaivere, and t h e l i k e . The applicable
fr%guency range of t h i s requirerent is dependent aa t h e operating frequency of t h e tut r u p l e ,
an specified i n MIL-STD-462. l o r Amy e q u i p c n t and subayrtema t h e r q u i r e r n t i r applicable
only vhen e p e c i f i c a l l y c a l l e d out i n the procurement documentation.
10.2 CS05 limitr. h e t e a t raaple r h a l l not exhibit, due t o c r m s .odufation, any
malfunction, degradation of parforamem, o r deviatibn from epecified indications, beyond t h e
tolerancee indicated i n t h e individual equiprant o r eubayrtem mpecification, when'rubjected t o
t h e following from r i g n a l generator 12: a s i g n a l 66 dB above t h s l e v e l required t o obtain t h e
rtandard reference output, ar rpeeified i n HIL-51D-462, but not t o exceed a power output l e v e l
of 10 d&.

11.1 CSO6 ~ p l i c a b i l i t y . T h f a requirement ir applicable t o q u i p m n t and subsystam AC


and DC power leads, including grourrcln and n e u t r a l r , which a r e not grounded i n t e r n a l l y t o t h e
equipaent o r subsyetem.
Downloaded from http://www.everyspec.com

11.2 CS06 U d t e . Tbe t e a t eaaple a h a l l not e x h i b l t any m l f u n c t i o n , d e g r a d a t i k of


pemfomance,. o r deviation from epecified indicatione, beyond t h e tolerances indicated i n t h e
i n d i v i d u a l equipment o r rubeyetem epecification, when t h e t o a t epikea having t h e waveform
shom on Pigure 4-9,are applied t o tbe AC a r t DC power input leade f o r a period of not l e e s
than I minute a t each phase poaition, and f o r a t o t a l t e s t period not exceeding 15 d n u t a e i n
duration. ( i n l i e u of t h e values! i n lIIGSa)-462). The valueo of B() end
The epike a h a l l be euperilapoeed on the pouirUne voltage wavefom.
to
a r e givan below.

a.
6.
Spike #I (Army)
Spike 4 2 (Navy)
El
B2
-- 100 Volts;. tl
400 Volte; t 2
-- 10 Idcroreconde
5 miuoeecoade
+ 20%.
+ 20%.
12. CSO7 (limited a p p l i c a b i l i t y )

12.1 CS07 a p p l i c a b i l i t y . Thie requirement i a applicable f o r receiving equipment md


eubspetema which u t i l i z e equelch c i t c u i t e .

12.2.1 Bequirewnt 1. l'he nquelch c i t c u i t e e h a l l not open when the output of ' a 5O-oh.
impedance impulse generator, e a t a t 90 dB pV/HRx, i e applied and matched t o t h e i n p u t t e r r i n a l r
of t h e t e a t eampie.

12.2.2 ilequiremene'2. The equelch c i r c u i t s h a l l not open when two eignale a r e applied
a t t h e input of the. t e a t eample. One e i g n a l . e h a l 1 be an uumdulated UP s i g n a l a t t h e ' r e c e i v e r
tuned frequency, whocle amplitude i e hpo-third8 o f ' t h e RP voltaga used t o a d j u s t the nquelch
threehold. Zhe eecond signal s h a l l be an impulse a i g n a l of 50 dB vV/Wa.

13. CS09 ( l i m i t e d a p p l i c a b i l i t y )

13.1 CS09 a p p l i c a b i l i t p , Thie requireeent is applicable t o Navy equipmnt and eubuyetema


t h a t have an operating frequency range of 100 kBz o r l e e a and a n operating e e n e i t i v i t y of 1
o r l c e e , such a s 0 . 5 pV. Other applicatione of t h i e requitemant are t o be de t e d n e d on a
case-bp'csse bssie.

13.2 a 0 9 linit.' I h e t e a t sample s h a l l not e x h i b i t any malfunct Lon, degradation of


performunee, o r d e v i a t i o n from epecified indicatione, beyond t h e tolerances indicated I n the
- i n d i v i d u a l equipmnt o r r u b y e t e a ep'ecification, when subjected t o t h e l e v e l s ahom on.
Figure 4-10 across t h e applicable t e s t points.

14. CS1O ( 1 W t e d a p p l i c a b i l i t y )
14.1 CS10 a p p l i c a b i l i t y . Thin electroaagnettc pulea (IMP)requireaent i e applicable t o
Navy equipment a d eubsyatem i n t e r f a c e p l w and terminale of pomr leade, c o n t r o l leade,
e i g n a l leads, and grouade and a e u t r a l a which a r e not grounded i n t e r n a l l y t o t h e equipment o r
eubsystm. ApplLcatiwe of t h i e r a q u i r w n t a r e t o be determined on a me-by-cane baeie.
It should be noted t h a t i f t h e equipment k t o be i n s t a l l e d i n an i n t e a t i o n a l l y unhardened
(unehielded) area, t h e equipment w i l l not bo adequately protected againat the s p e c i f i e d HLID.

14.2 CSlO l i m i t . The t e s t eample e h a l l not w h i b i t any p e m n e n t malfunction, degradatioa


of performance, o r deviation from epecified indicatione, beyond t h e tolerance8 and t a c o v e v
t h e e indicated in the individual equipment o r eubeptem s p e c i f i c a t i o n , a f t e r being subjected
t o a t e a t e i g r u l having e i t h e r t h e waveform and c m m n mode c u r r e n t l e v a 1 ehown on t i g u r a 4-11,
ae determined i n accordance with HItSR)-462.

15. ~ ~ 1(limited
.1 a p p i i c a b i l i tyj

15.1, CSll a p o l i c a b i l l t y . This BIP requirement i e applicable t o Navy equipment and


eubsyetem having interconnecting o r i n t r a c o n ~ e t i n gcontrol, e i w , o r ponr cablee. It
ehould be noted t h a t i f t h e equipment i e t o he i m t a l l e d i n an i n t e n t i o n a l l y urhardeaed
(unehielded) a r e a , t h e equipmnt w i l l not be adequately p r o t e a e d a g a i n s t t h e npecified EMP.
Actual cable types, e i z e s and configuratioar eubjected t o t h e rpecffied US05 l w o l e a r a
exempt from meeting t h i e requirement.
Downloaded from http://www.everyspec.com

15.2 CSll l i m i t . The t e a t aample r h a l l not e x h i b i t any perranant malfunction, degradation


of perforlance, o r d e v i a t l o n from r p e c i f i e d l n d i c a t i o n a , beyond tho tolerance8 and recovery
timea indicated i n t h e equipment o r ruboyrtem r p c i f i c a t i o n , a f t e r baing subjected t o a t e a t
rigwl having t h e vaveforn rhom i n Pigure 4-12 nail h d n g a aaxinum bulk c a a w n mode cable
c u r r e n t of 10 ampr, ao d e t e r d a e d i n accordance with WLt.8n>-462.

16. RE01 ( l i m i t e d a p p l i c a b i l t t y )

16.1 BBOl a p p l i c a b i l i t y . Thin requirement i r a p p l i c a b l e f o r Navy equipment a d aub-


ryeteaDll i n r t a l t e d i n fixed o r w b t l e ground f a c i l i t i e r . Other a p p l i c a t i o n o of t h i n requirement
a r e t o be determined on a care-by-care baair. *en required, RBOl i a a p p l i c n b l e f o r radlated
emiraiono f r o r equipnent and a u b s y r t e w , c a b l e s (including c o n t r o l , p u l r c , IP, pawar, and
antennae traarmierton l i n e r ) and laterconnecting wiring of t h e t e a t saaple. The requirement
a p p l i e r a t t h e f u n d a m n t a t frequencter and a11 epuriouo emirsionr, including h a r m n i c e , but
doeo not apply t o r a d i a t i o n from antennar.

16.2 RE01 l i m i t . I h g n e t l c f i e l d emiaaiono s h a l l n o t be radiated i n exceoa of t h e l e v e l s


a h o m on Figure 4-13.

17.1 RE02 a p p l i c a b i l i t y . Thin requirement is applicable f o r r a d l a t e d e m i r r i o m from


equipment and rubryatetw, cabler (including c o n t r o l , pulre, IF, pover, and antennae trans-
miasion l i n e r ) and lntercoanecting v i r i n g of t h e t e n t rample. For narrowband, i t applieo a t
tho fundamental f r e q w m i e r and a11 rpuriour e d a a i o n a , includtng harmonica, but doeo not apply
t o r a d i a t i o n from antennae. Thin requirement i r applicable f o r broadband emiratone f r o r 14 kHz
t o 1 GHz and f o r narrowband emisrions from I 4 kllz t o 10 CUz.

17.2 RE02 l i d t r . & f i e l d e a i s r i o ~r b a l l not be radiated i n excesr of thoae given i n


17.2.1 and 17.2.2. Above 30 IMz, t h e l i d t a e h a l l be pet f o r both h o r i z o n t a l l y a ~ vd e r t i c a l l y
polarized waver.

17.2.1 Narrowband e l e c t r i c f i e l d e d a a i o ~ . Umrrovband E-field emiariona rhall not be


radtaeed i n exceao of t h a applicable 1LmLt curve shown on Pigure 4-14 a t t h e required t e a t
d i e tance , aa apeci f ied i n MIL-SCO-462.

17.2.2 Broadband e l e c t r i c f i e l d elpiariow. Broadband B-field emissions from a l l equipment


and aubaptema, including r a d t a t e d r v i t c h i n g t r a n a i e n t e resulting f r o n (1) automatic cycling
of e l e c t r m i c o r e l e c t r i c a l switching c i r c u l t r y , (2) a c t u a t i o n of purh-tu-talk meehaairm
( t h a t i a , keying of t r a n r m l t t e m ) , o r (3) manual rwitchtng a h a l l not be r a d i a t e d i n exceaa of
t h e l i m i t curve ehovn on Figure 4-15 a t t h e required t e a t dietancee, a s specified Ln HIL-8TD-462.

18. RE03 (limited applicability)

18.1 RE03 a p p l i c a b i l i t e This rsputrement i a applicable f o r thoae equipment and eubayrteme


vLth antenna leada o r thore deeigned t o be connected t o aatennar. The frequency rango of t N a
requir-nt l a dependent on t h e operating frequency of the t e a t sample (eee MIL-STD-462). The
r e q u i r e a n t i a not a p p l t c a b l e within e l t h e r the t k a t r a a p l e ' a necessary bandwidth o r +
5 prcont
of the fundmental frequency.
18.1.1 Army prbcurementa. This requirement i a a p p l i c a b l e f o r t r u u d t t i n g equipment and
aubayate.e procured a o l e l y f o r Army ure, when any of t h e f o l l o v i n g conditlona e x i a t : (a) trane-
d t t e r power exceeds 5 kW average. (b) t h e fundamental frequency of t h e t w t a r ~ p l ee x c d a
1.24 CBr, (c) t h a t e e t eaaple'o antenna is an i n t e g r a l part of t h e t r a n e m i t t e r and cannot be
replaced by a r u i t a b l e dummy load, o r (d) f o r equipaent o r rubeyatem with waveguide tranomiraion
l i n e a and operating belov 1.24 CBz.

18.1.2 Navy procurementr. Thia r e q u i r e m a t i r applicable, r i t h t h e approval of t h e


procuring a c t i v i t y , when t h e apuriour e d r a i o n a and hamonice cannot k determined w i n g t h e
procedures Ln -6.
18.2 RB03 l i m i t . b r m o n i c r , except t h e accond and t h i r d , and a l l o t h e r apurioua
e r i s s i o n a a h a l l have peak porarr 80 dB d w n from t h e power a t t h e f u n d a w n t a l . The second
and t h i r d harmonica a h a l l be auppresaed by: 50 + 10 l o g P (where P 0 peak poper, i n w a t t r ,
a t t h e fundamental) o r 80 dB, whichever requirea l e e s suppreeaion.
Downloaded from http://www.everyspec.com

19. , RSOl (liPLted a p p l i c a b i l i t y )

. 19.1 B601 a p p l i c a b i l i t y . Thie requirement i e a p p l i c a b l e f o r Navy equipment and eub-


s y s t e m i w t a l l e d i n fixed o r mobile ground f a c i l i t i e s ; Other applications of t h i r requirement
a r e t o be determined on a caee-by-cwa h i e . When required, US01 i n applicable t o equipment
and e u b s y s t e ~ eand t h e i r , a s e a c i a t e d cabling and connectors.

19.2 US01 limit. The t e s t eempla e h a l l not a x h i b i t any permanent malfunction, degradatlon
of performance, o r deviation from s p e c i f i e d indications, beyond t h e tolerances indicated i n
t h e i n d i v i d u a l equipment o r subsyetea epqcification, when eubjected t o emgnetlc P i e l d r l a s e
than o r equal t o t h e l e v e l a ehown on Figure 4-16.

20.1 8502 a p p l i c a b i l i t y . This requireaent.ie applicable t o equi'paant and r y e t e a s as


i n d i c a t e d i n 20.1.1 and 20.1.2.

20.1.1 Part I - spikes. This portion ofRSO2 i e applicable f o r a l l DoD activities.


20.1.2 -
P a r t I1 power frequency. Thie r e q u i r e m n t is a p p l i c a b l e f o r equipment and
e u b y s t e a e procured f o r Navy use. For Army equipment and eubeystems, t h e requirement is
a p p l i c a b l e only when s p e c i f i c a l l y c a l l e d out i n the procurement,documntation.

20.2.1 -
P a r t I epikea. The t e a t s q p l e s h a l l not .e%hibit any nalftmctton, dagradation
of perfomsnce, o r deviation from ~specifi'edi n d l c a t i o m , beyond t h e tolerances indicated i n
t h e 1 . d i v i d u a l equipment o r eubeyatam epecification, when subjected t o the t e e t spiken having
t h e waveform ahown on Figure 4-9. The value8 of E() and to
a r e given below:

a. Spitre i.1 (Army) 111 = l W Volts; ti - 10 mLcroeecwds + 20X.


b. s p i k e 12 (Navy) B2 = 400 Volte; t 2 5 microeeconde + 20X.
-
20.2.2 P a r t 11 power frequeac .
The t e s t sample s h a l l not e x h i b i t any a l f m c t i o n ,
degradation of performance, o r deviatfon from specifled i n d i c a t i o r , beyond t h e tolerancee
i n d i c a t e d i n t h e i n d i v i d u a l equipmut o r subsystem speciEication, when 20 c u p t e e a m applied
t o t h e t e e t wire a t t h e power Erequancy(iea) of t h e teet'sample.

21.1 RS03 a p p l i c a b i l i t y . This requirement i e applicable f o r a l l aquipmnt and subsyrteme


between 14 Ulr and 10 CHz. Above 10 G b t h f s requirement is not mandatory unless o t h e r u i a e
required by t h e proacting a c t i v i t y .

21.2 8803 limits. The t e a t sample s h a l l not e x h i b i t any parranent malEmction, degrada-
t i o n of perforaance, o r deviation from specified i n d i c a t i o n s , beyond t h e tolerances indicated
i n t h e i n d i v i d u a l equipment o r rubryetea s p e c i f i c a t i o n , when subjected t o t h e radiated e l e c t r i c
f i e l d s (B) epeciEied herein. Above 30 nBs, the r q u i r e r e n t s h a l l be mat €or both h o r i s m t a l l y
and vertically polarized waves; c i r c u l a s polarized waves a r e a l s o acceptable. Appropriate
c o w i d e r a t i o n s h a l l be giveu t o t h e operational radiated electromagaetic environment from bath
f r i e n d l y and h o s t i l e emittern which en equipnent o r s u b e y s t e m ' ~ ye r o u n t e r during i t s l i f e
cycle. Applicable portions of IIIL-EDBK-235 s h a l l be w e d t o d e t e d n e the m t i c i p a t d environ-
w n t . Am a ainimum, t h e follololug l e v e l a apply. I f l e v e h s u b s t a n t i a l l y higher than thoee
given h e r e i n e r e epecified, w d i f i c a t i o o e t o the procedure i n HIL-STD-462 may he required o r
desirable. Such m d i f i c a t I O ~a~r e t o be described in t h e KHZ T e s t Plan.
Downloaded from http://www.everyspec.com

Wiry
Frequency Range Army RCVR a i t e o A l l o t h e r Navy a i t e a

14 kHz t o 2 lPlr 1 1 10
2 t o 3 0 a 10 1 10
30 to 2000 HlIz 5 1 10
2 to 10 GEz 5 1 40
Above 10 Cklz 20 1 40

22. R805 (limited a p p l i c a b i l i t y )

22.1 RS05 a p p l i c a b i l i t . This rcquireront is intended f o r Navy equipment and s u b s y a t e l s


and l a a p p l i c a b l e when both $£ t h e f o l l d y coaditiona e x i a t : (a) operation of t h a equipment
o r aubayatem i a essential f o r t h e eucceee of a miaaion and (b) t h e equipocnt o r aubeyatam i r t o
be located o u t a i d e of an i n t e n t i o n a l l y hardened (shialded) area. f h i a requirement l a not
applicable f o r equipocnt intended s o l e l y f o r uee i n n o n - m t a l l i c ground f a c i l i t i e s , unleaa
o t b n i a e required by t h e procuring a c t i v i t y . Cables t h a t can not be t e n t e d l a accot&nca
with MIL-B10-462 o h a l l meet t h e requirements of CSl1, aud cablea a u b j e c t d t o t h e o p e c i f i e d
CSll l e v e l s a r e exeapt from meeting t h i n requircaent.
22.2 RS05 limlt. The t e a t aample a h a l l not e x h i b i t any permanent malfunctiou, d a g r d a -
t i o n of performance, o r d e v i a t i o n from s p e c i f i e d i n d i c a t i o n r , beyond t h e t o l e r a n c e s and
recovery t i l e a i n d i b t e d i n t h e i n d i v i d u a l equipment o r subsystem r p e c i f i c r t l o n , a f t e r k i n , g
aubjacted t o a t e a t s i g n a l having t h e waveform and amplitude a h o m on Figure 4-17.
Downloaded from http://www.everyspec.com

FIGURE 4-1. UMlT FOR CEO1 DC AND INTERCONNECTING


LEADS
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com

FIGURE 4-4. UMlT FOR CEO3 BROADBAND EMISSIONS DC AND


INTERCONNECTING LEADS AND AC LEADS (ARMY)
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com

Limit

fo - Receiver tuned frequency o r bad center f o r amplifiers.

fl - Lowest tunable frequency of receiver band i n uee o r the lowest frequency


of amplifier p a s s b a d .
f2 = Highest tunable frequency of receiver band i n use o r the higheat frequency
of a r p l i f ier' parsband..

W = Bandwidth between t h e 80 dB points of the receiver a e l e c t i v i t y curva a r defined


i n the t e a t a m p l e ' s technical requirementa o r t h e control plan.

1. The l i m i t a t A i e 80 dB above t h e input level required t o produce the standard


reference output. (Thir l i m i t a h 1 1 not be m a d f o r amplifiers)
2. The l i m i t a t B r h d l be r a t ao follower
a * Receiverot 0 d h applied d i r e c t l y t o the receiver input t e m i n a l r .
b b Amplifiers: The l i l i t ' r h a l l ba aa specified i n t h e t o r t aarple'a technical
requirerent o r . c o n t r o 1 plan. I f no l i m i t i e defined i n the above docuacata,
the 0 dBm value a h a l l be ured.

FlGURE 4-8. LIMIT FOR CS04


Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com

--ntt

FIGURE 4-11. LIMIT FOR CSlO

4-20
Downloaded from http://www.everyspec.com

Frequency (MHz)

--nft
whm,

(t) = common mode cable


lcA=e unml k anp.
f freq4Janq, harm
4 t rth,secondr

FIGURE 4-12. UMlT FOR CS11


Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com

E, 3 FIELD STRENGTH IN KILOVOLT/METER


ir = RISETIME IN SEC,
id 3 OURATION PULSE WlOTH IN SEC.
if a FALLTIME IN SEC.

FIGURE 4-17. LIMIT FOR RS05


Downloaded from http://www.everyspec.com

Part 5. Equipment and Submysteu


I w t a l l e d i n Surface Ships (clams ~ 4 )
Downloaded from http://www.everyspec.com

P a r t 5.

SCOPE
Determining requirements .
g*eaptiow f o r i n t e r f e r e a c e fy- e l e c t r i c a l
a d ele.ctrowchapica1 e q u i p a n t
gtcsptioru f o r aoireq.seatial e l e c t r i c a l and
e l e c t r o m c h a n i c a l equipaent

a 1
CWl a p p l i c a b i l i t y .
DC and i a t e ~ c o o n e c t i n gl e d 8
AC l e a
CEO1 l i a i t q
DC l e a d s
AC leads
Inteteoanecting leads
Connected o u t e r s h i e l d a* twisted together '

o i k o a n e c t e d o u t e r shield and twisted p a i r s r e p r a t e d

CEO3
CEO3 a p p l i c a b i l i t y
(803 l i m i t s
DC lea&
AC leeds
Enterwrmaetfng leade
b a n e c t e d oirter s h i e l d a d rw$ated p a i r s together
Dircoanected outer shield and M a t e d p a l m separated

a06 (limit& applicabiL&ty)


CEO6 applicability,
CE06 l i d t a ' '
,

Bsceivem
R a w d t t e m (key-yp and s t a d b y )
T r a n d t t e r s (key-dom mde)

C801
CSOl a p p l i c e b i l i t y
C801 I i m i t s

cSO2
CsO2 a p p l i c a b i l i t y
CsO2 l i d t s

. C803 (limited a p p l i c a b i l i t y )
CS03 ' a p p l i c a b i l i t y
CS03 l i a i t r

C805 (limtted a p p l i c a b i l i t y )
-5 applicability .
CS05 l i m i t s

C806
CS06 a p p l i c a b i l i t y
CSO6 limits

&07 ( l i m i t & a p p l i c a b i l i t y )
CS07 a p p l i c a b f l i t y
lidts
R e q d r e ~ n t1
B e q u i t e ~ e n t2
Downloaded from http://www.everyspec.com

' CotJTmS (Continued)

Part 5

Paragraph 12. CW9 ( l i d t a d a p p l i c a b i l i t y )


12.1 CB09 a p p l i c a b i l i t y
12.2 CEO9 l i m i t
CS10 (limited a p p l i c a b i l i t y )
CSlO a p p l i c a b i l i t y
CSlO lidt
CSll (limited a p p l i c a b i l i t y )
CSll a p p l i c a b i l i t y
CSll lidt

RWl
RE01 a p p l i c a b i l t t y
RE01 l i m i t
RE02
RW2 a p p l i c a b i l i t y
BBO2 -It#
N a r r w b n d e l e c t r i c f i e l d ealeeione
Broadbud e l e c t r i c f i e l d emieaioru

17. R ~ 0 3(lldteul applicability)


17.1 RB03 a p p l i c a b t l i t y
17.2 Re03 lidt

RSOl
R601 a p p l i c a b i l i t y
RSOl l i m i t 6
BWlZ
RW2 a p y l i c a b i l it y
8302 l u t e
-
P a r t I apikes
P a r t I1 -.power frequency

11503
RSO3 a p p l i c a b i l i t y
8503 lidt.

21. PS05 ( l i r l t e d a p p l i c a b i l i t y )
21.1 RS05 a p p l i c a b i l i t y
21.2 US05 l i m i t

5-1 ~lmiaaiona d a u o c e p t i b i l i t j r q u i r - t o for


c l a m M equipment and a u b a y a t e u
Downloaded from http://www.everyspec.com

Part 5

L i d t f o r C m l DC and iaterwmecting l e a d .
L i d t f o r CEO1 AC bade
Lidt for CEO3 mrropbad edaaioda' DC a d
intarconaec&in# had8
L h t t f o r CE03 b r d b a a d e m i a r i o ~DC and
lntercwueeting l e a d
L i d t f o r CEO3 narrowband e c r i s s i o ~AC l e d a
. L i d t f o r CEO3 broadband e d a r i o n e AC leads
t i d t for CSOt
L i d t f o r CS04
bccept~blewavesheper f o r CSO6 a d RS02
L i d t for CS09
LilLt for C S l O
Limit For CS11
Lhtt for R E 1
U&t for .RE02 ~ r t o p b a n da f r s i o n r
Limit For RBOZ broadband emieeiow
Limit for RBOl
Limit For 'RSO5
Downloaded from http://www.everyspec.com

Thia part of ML-STD-461 a u p p l e r n t s P a r t 1 of t h e atandard by defining emiaalon and


a r w e p t i b i l i t y requiremnta and limltr Cor e q u i p r m t and a u k y e t e m intended f o r u r e i n
rurfaca shipa ( C h a r A4).

1.1 Determini- requirements. Table 5-1 r h a l l be w e d t o d e t e r r i m t h e a p e c i f i c


requiremnta f o r C l u e A4 equipment and aubystemr. The t a b l a a l a o denotea t b paragcapha
whareln' t h e raquiraranta and l i d t a a r e defined. A "Y" 'antry i n t h e t a b l e mema the.rquirement
i r applicable, and t h e lidt a h a l l be at w i n g t h e procodurea i n IIIL-S-62 o r t h e approved
gllZ Tewt Plan. vL'
A e n t r y w a r n t h e a p p l i c a b i l i t y of t h e t e q u i r e w n t i a l i r i t e d and i a
apecified i n t h e approprlat.e correapoading paragraph. The l i m i t r h a l t be mat w i n g t h e proccdurer
i n HIL-STD-462 o r t h e approved MI Teat Plan. A "T' e n t r y mane that t h e a p p l i c e b l l i t y u a t
be determined on a care-by-caea baaia a d , i f t h e require.ent i a t o be impored, I t mwt be ao
rpecifled i n t h e appropriate procuralrent docurtnt. When required, t h e lidt a h a l l ba met u r i n g
the procedures I n UTL-STD-462 o r the approved BII Teat Plan. Abaeoce of an'entry mano t h e
requiremnt i a not applicable. ?or procuremmta of aubyatemo, much u radar, EW ~ ~ i l l a n c e ,
and t h e l i k e , coanprhed of individual equiprant l i s t e d i n Table 5-1, t h e applicable a i a a i o n
and a u a c e p t i b i l i t y requiremanta f o r t h e aulmyotu a h a l l be t a i l o r e d by t h e procuring a c t i v i t y
b a e d on the r q u i r e w n t a of t h e individual equipment.

1.2 Exceptloru f o r i n t e r f eranee f r e e e l e c t r i c a l and electromechanical equipmat. There


a r e e l e c t r i c a l and electramchanical e q u i p r n t which a r e uaually interference f r e e and f o r
which written approval t o forego e d a a i o a t e e t i n g m y be obtained when procured a a individual
equipaznt. An a means of eatabliahing whather an e q u i p r n t w i l l require teeting, t h e e q u i p m a t
~ n u L a c t u r e rr h a l l C o m r d t o t h e Co~lllrndo r agency concarned a complete electrical deocriptioa
of t h e equipment and t h e j u a t i f i c a t i o a t o forego testing. Written apprgval t o foreso t e r t l n g
u a t be obtained ,obtained from t h e Conand o r agency concerned aod a h a l l be r q u e a t o d u e a r l y
i n t h e p r o c u r u e n t cycle an poaaible.
1.3 Exeeptiolu f o r nonesaential e l e c t r i c a l and electrorcchanical equipment. Ibs foliowlng
e l e c t r l c a l and electromechanical equipment a r e comidered noneeeentlal and need not m e t the
auaceptLbillty requireaenta apecified herein.
a Racreatioual equipment, auch an e l e c t r i c a l g-a
Vanding machinee

2.1 CEO1 a p p l i c a b i l i t y . Thia r o q u i r a e n t is applicable f o r a l t e r n a t i n g c u r r e n t (AC) and


d i r e c t current-(DC) leada, which obtain ponur from o t h e r aourcea o r provide power t o otber
equipaent o r aubyatema; grounds o r neutrals, which a r e not grounded i n t e r n a l l y t o t h e aub-
ayatem o r equipment being .easured; and inteycommcting c o n t r o l leads, which p r w i d e AC aad #:
power from o r t o t h e t w t aample. Tbe r q u i r a r a n t i a not applicable f o r iaterconnecting.aigno1
lead6 much u elock, IF, audio, f i r i n g , d i g i t a l , R?, and t h e l i k e , unleaa o t h a n i ~r p a c i f i e d
by the Colaund o r agency concarned.

2.1.1 DC and laterconnecting leada. Thin requirement i a applicable f o r narrowband


e d s a i o n a From 30 Hr t o 15 IrRa.
2.1.2 M: laada. Thla r e q u i r e m a t i e appllcable f o r narrovtmnd e d a r i o m E r a t h e power
f r e q u e n c y ( i e ~ et e a t a m p l e t o 15 kUz.

2.2.1 DC l e d a . Blectromgnetic amiaaionr a h a l l not appear oa IX: led. i n a c e a a of t h e


reluea ahom on Figure 5-1. The l i d t a a h a l l be u e t h a r a r u r e d v l t h an e f f e c t i v a bandwidth
not exceeding 75 Ms.
2.2.2 AC l d a . E l e c t r o w g n e t i c e d a a i o w a h a l l not appear on AC leada i n u c e a a of the
valuer, ahown on t h e applicable lidt l i r i C on Figure 5-2. The l i m i t . r h a l l be met when u a u r o d
v i t h an e f f e c t i v e bnndddth not sxcooding t h e primary power frequency plum 20% of, tbe primary
parar frequency.
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com

FIGURE 5-6. UMIT FOR CEO3 BROADBAND EMISSIONS AC LEADS


Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com

Limit

f o = Receiver tuned frequency o r band center f o r amplifierr.

fl - Lowest tunable frequency of receiver band i n ure o r the lawart frequancy

-
of amplifier paarband.

f2 Bigheat tunable frequency of receiver bard i n ure o r the hlgbert frequency


of amplifier paraband.

W - Baadddtb between t h e 80 dB pointr of the receiver selectivity curve an defined


i n the t e s t rample'r tee?mlcal requirewntr o r t h e control plan.

'1. The l l d t a t A is 80 dB above the input leva1 required t o produce the rtandard
reference output. (Thir lidt r h a l l not be ured f o r amplifiem)
2. The lidt a t B r h a l l be net as follows:
a. Beceivcra: 0 dBm applied .directly t o the recaiver input terriacrlr.
b. k p l i f i e m : The l i m i t rhnll be a s rpacified i n the t e a t rample'r technical
reqoiresmnt o r control plan. If no l i m i t i r defined i n the above docmentr,
the 0 dBm valua rhall be ured.

FIGURE 5-8. LIMIT FOR CS04


Downloaded from http://www.everyspec.com

-
NOTE: The test aample shall be subjected to the spike(a) with the .waveform shown and
with the specified voltage ($1and pulsewldth (s) .

FIGURE 5-9. ACCEPTABLE WAVESHAPES FOR CS06 AND RS02


Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com

FIGURE 5-11, LIMIT FOR -10


Downloaded from http://www.everyspec.com

.01 .1 1. 10. 100.

... Frequency'(MHz) . ..

]CCABLE (t) = common mode cable


current in amps
f = tnqclsney, hertz
t = tkm,8oconds
QodwayketO?

FIGURE 5-12. UMlT FOR CS11


Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com

Part 6. &piplent and Subeystem


Iaotalled in 'Submrines (Class 65)
Downloaded from http://www.everyspec.com

Part 6

Paragraph I. smx
1.1 h t e w n i a g requireaente
1.2 Except!onr f o r icptederenca f r e e qdpradnt
1.3 Bxceptiona for noneeaentiat e l e c t r i c a l and
elrcrrameehaalcal equipment

mi
CEO1 applicability
DC and laterconnecting leads
Ac lead.
CEO1 L i d t e
DC .leadm
(U: lead.
Intercoanecting leatin . .
Connected outer ehield and twisted pair8 together
Disconnected outer ehield end twisted pairs reparated

CEO3
CEO3 applicability
CB03 I l r i t a
DC Laah
AC. leada
Ietercoonecting leads
Connaeted outer ehield and t l i a t e d pail* together
Di8connected outer shield end M e t e d pain atpatated

4. . CB06 (limited 8 p p l i c r b i l i t y )
4.1 CEO6 applicability
4.2 limits
4.2.1 ' Eaceivars
4.2.2 T r a n s d t t a n (hay-up and 8taadby)
4.2.3 Ttammittera (heydorm .ode)
Csol
CSOl applicability
CSOl limits
C602 (limited applicability)
C802 applicability
CSO2 limits .

CS03 (limited applicability)


C803 appli6ablUty
-03 limita
CSa4 ( l i d t e d e p p l i c i b i l i t y )
CSO4 applicability
C804 lMt8
CS05 (limltch. rpplicabili y)
CSO5 applicabi l f y
CSO51+te' .

CSO6
CSO6 applicability
CM)6 limits
CSO? (limfted applicability)
CS07 applicability
C807 limit.
Requirement 1
Requirement 2
Downloaded from http://www.everyspec.com

Part 6

Paragraph 12. CS09 (limited applicability)


12.1 -09 applicability
12.2 CS09 lidt
13. CSIO (limited applicabilfty)
13.1 (310 applicability
13.2 CS10 limit
14 CSll (limited applicability)
14.1 C a l l applicability
14.2 CS11 lidt

15. aaOl
15.1 BBOl apphcabiltty
15.2 RE01 limit

m 2
BgO2 applicaMUty
RE02 l i a i t e
Harrowband elect-ria f i e l d emissionr
Broadband electric f i e l d d e r i o n a
RE03 (limited applicability)
BB03 applicability
RE03 limit

RSO2
BSO2 applicability
11802 lidtll :
-
Part I clpikee
-
Part I1 power frequency
8903 .
RS03 applicability
as03 l i r i t e
21 .
21.1
RSO? (limited applicability)
RSO5 applicability
21.2 m 5 limit

Bnieeion w d mrceptibiuty requiiemnti for


claea AS equipment and clnb?pstemm
Downloaded from http://www.everyspec.com

Q1NTENTS (Continued)

Part 6

Limft for CgOl DC and Lnterconnectiw Lea&


L h l t f o r CBOl AC leads
e d r r i o n r DC and
L i d t l o r CEO3 narrowbn~~d
interconnecting leads
Limit f o r CEO3 broadband eaieaiona M: and
interconnecting leadr
L h i t f o r CEO3 narrowband emieeione AC leade
Limit for CEO3 broadband emleeion. AC Lea&
&it f o r CSOl
L i r i t f o r CSO4
Acceptable waveshapa. f o r CS06 and RSO2
LLmit f o r CS09
L i n i t f o r C810
L h i t f o r CSll
Limit f o r RE01
L i d t l o r ReO2 anrrowband d r r i o n r
Limit f o r RE02 broadband emieeiona
Limit f o r W01
Limit f o r RS05
Downloaded from http://www.everyspec.com

1. SCOPE

This part of MItSTD461 suppleaante Part 1 of the s t a p i a r d by d e f i n l w t r i e s i o n and


s u s c e p t i b i l i t y requirements and l i d t s for equipment and s u b y a t a s intended f o r use i n
s u h s r i n e e (CLass A5).

1.1 D e t e d n i q l requirements. Table 6-1 s h a l l be used t o d e t e d n a the a p e c i f t c


requir-ts f o r clams M equipmnt and subeyeteas. h e t e b l e a h dcnotee the peragraphr
uberein the requiremnts and l i m i t s a r e defined. A "Pa entry i n the t a b l e mema t h e require-
r e n t is applicable, and tbe lidt s h a l l b e ' m t w i n g the procedures i n nXL-STD-462 o r the
approved BHI Teat Plan. A "YL' entey maxu tbe a p p l i c a b i l i t y of the requirement is ltmitd
and i e specified in t h e appropriate corresponding paragraph. The limit shall be met ueing
t h e procedursr i n ML-STD-462 o r t h e approved €MI Teat Plan; A "T" e n t r y means t h a t the
a p p l i c a b i l i t y must be determined on a caee-by-caee basis a d , i f the requirewnt is t o be
imposed, i t uet be 60 specified i n the appropriate procurement document. When required,
tho l l d t shall be met w i n g t h e procedure# i n MIL-STD-462 o r t h e approved BlIf Test Plan.
Abeence of an e n t r y m a n s the r e q u i r e m a t is not applicable. For procureant8 of eubeystew,
such a s radar, EW surveillance, and t h e l i k e , comprised .of individual equipment l i e t e d i n
Table 6-1, t h e applicable d e s i o n ' a n d eueceptibility, requirementr f o r the subeystem s h a l l
be tailoyed by the procuring a c t i v i t y based on tha requiraments oE t h e individual equipment.

1.2 Exceptions f o r interference f r e e equipaent. !the& a r e electrical aad elect;*


mechanical equipment otrich a r e usually interference f r e e aad f o r vhich written approval t o
forago aniseion t e s t i n g n y be obtained when procured as individual e q u i p ~ c n t . An a a a a of
estnblfshing whether an equipment w i l l require t w t i n g , ~ t h e . e q u i p e n tmnufacturer s h a l l
forward t o t h e Commaad o r agency concerned a coaplete e l e c t r i c a l dorcription of t h e equipment
and t h e j u e t l f i c a t i o n t o forego tenting. k i t t e n a p p r w a l t o forego t e s t i n g must be obtained
f r o l the Conmnnd o r agency concerned and s h a l l be requeeted a e e a r l y i n the procuremnt
cycle ae poeeible.

1.3 Ikceptions f o r nonessential e l e c t r i c a l and electrcaechaaical equipment. The following


e l e c t r i c a l and electrolcehenical equipment a r e conaidered nonesoacttial and need not r e e t the
e u e e e p t i b i l i t y requi remente specif fed herein.

Recreational equipment, euch a s e l e c t r i c a l g-s


'Vending muchinee

2.1 CEO1 applicability. Ihis r e q u i r e n t is applicable f o r a l t e r n a t i n g current (AC) and


d i r e c t current (DC) leads, which obtain powat from other sources or provide pover t o other
equipment o r subeystema; grounds o r neutralr, which a r e not grounded i n t e r n a l l y t o the subeyeten
o r equipment being measured; and intercoanecting control leads, which provide AC and DC power
from o r t o the t e s t sample. f i e requirement is not applicable t o r interconnecting signal leade
such ae clock, IF, audio, f i r i n g , d i g i t a l , I@,
and t h e lib! unlese o t h e n i u e epecified by t h e
Comaand o r agency concerned.

2.141 DC and interconnecting leads. mis requiremat is applicable f o r norrowbud .


e d s s i o n s from 30 Ilr t o 15 Igs.
2.1.2 I+& leadn. This requirement is applicable f o r narrowband d e s i o n a from the powor
frequency(1es) of the t e s t sample t o 15 kEr.

2.2.1 DC leadr. Klectromegnetic eaiseionr e h a l l not appear on DC l e d 8 i n axcars of t h e


valuer shorn on Figure 6-1. The following limits s h a l l - b e met when lrcasured with an e f t e c t i v e
. '
bandwidth oot exceeding 75 Ha. . : I

2.2.2 AC leads. Hlectrcmqaetic e d w i o n e s h a l l not appear on AC leads i n excees of the


values shawn on the applicable lidt l i n e on Figure 6-2. The l i m i t s shall be r t &en measorad
with an ef h c t i v e bandwidth not exceeding the primary g~ouer!frequency. plus 20% of t h e p t h r y
power frqueacy.
'A tam
I Z J. 'A 'A
A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A
02 A A A mu
A A A & & & A A A A A A A A A A A A A A A A A A A A A A A A ~ ~
61 A A A - A A
A A & A A A A A A A A A A A A A A A A A A A A A A A A A A A A L O S I )
el A A A
1 1 'A '(A 'A 'A ODlU
A A A A A A A A A A A ' A A A A A A A A A A A A A A A A A A A A A m 3 y
-
A A C . A & A A A A A A A A A A A A A A A A A A A A A A A A L O 1 U
GI A A
'A A 1 A
' 1 'A A '(A '(A 'A 'A 'A 'A 'A 'A 'A 'A 'A 'A ?A 'A 'A '(A '(A '(A 'A 'A 'A 'A 'A LIm
1 1 1 1 1.1 1 1 1 1 1 1 1 1 1 1 1 1 . 1 1 1 1 1 1 1 1111IOLf3
'(A -A '(A 'A -A 'A 'A -A -A 'A 'A '(A '(A 'A 'A ?A 'A 'A 'A -A -A 'A 'A 'A 'A -A 'A '(A '(A '(A 'A 'A
21 'A 'A
'(A 10S3
Downloaded from http://www.everyspec.com

It
01 A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A ~
6 1 '(A A 1 A A A 1 1 1 A m
e 1 '(A 'A 1 1 1 1 1 1 A m
S 1
1
1 1
'(A
1 ~ 1 1 l A
A 1 A. A A 1 1 1 A m m
l. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 L O S J
A & A A A A A A A A A A A A A A A A A A A A A A A A A I A A A A & r n
5 A A
?s
'A '(A 'A 'A '(A ?A 'A 1 'A 'A B
On
t A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A
W ~
2 A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A
U ~ ~
C
= J
I
SW3ISAS8,CISaW lN3WdlnD3 SV
SSVl3 UOd SlN3W3UlnD3U NJllfllLd33SCIS ONV NOISSIm '1-9 3 7 8 V l
Downloaded from http://www.everyspec.com

2.2.3 Interconnecting leade.


2.2.3.1 Connected o u t e r s h i e l d and twiated pairs together. For interconnecting c o n t r.o l
and a l g n a l lea& having the outer r h i e l d connected, and f o r t a b t a d p a i r s with t h a p a i r e
together, electromagnetic ariaelone s h a l l not appear on tha lead6 i n exceaa OF t h e v a l u w
shown on Plpre 6-1. The lldte shall be met when pleasured with a n e f f e c t i v e bandwidth not
exceeding t h e primury power frequency plus 20% of t h e prlmary power frequency f o r AC leads o r
75 Ra f o r DC leads.

2.2.3.2 Disconnected o u t e r s h i e l d and twisted p a l r a separated. For interconnecting


c o n t r o l and signal lea& having the outer shield disconnected, and f o r t r i s t e d paira.having
t h e pair8 aeparated, t h e l i m i t s a h a l l be developed on a cam-by-caae b a s h conriderlng t h e
l n t e n t i o ~ ltranaaiaaioa, i t s specified power level, neceasary i n f o m a t i o n bandddth, a d
pula8 r i a e tlce. Such limits must be approved by the Colllvrnd o r agency conceraed.

.
3.1- CB03 e p p l i c a b i l i t This requirement l a applicable f o r a l t e r n a t l o g current (AC) uud
d i r e c t current (KC)leada, k i c h obtain.>&mr from'otber-i&rcea or provide prcr t o other
equipment o r aubeysteple; grounds o r neutrals, which a r e not grounded internally t o t h e sub-
s p a t e a o r equipment being measured; and interconnecting c o n t r o l l e d , which provide AC and DC
power Erom o r t o t h e t e a t eample. f h e requirerant t r not applicable f o r intercoanectiog
a l g n a l leads auch aa clock, IF, audio, f l r i a g , d l g i t a l , RF, and t h e like, unless o t h e m l a e
apeclEied by t h e Command o r agency cmceraed.
3.2 CW3 limits.

3.2.1 DC leada. Electromagnetic emiaalooe s h a l l not appear 00 DC leade La exceaa of t h e


values s h o m on Figures 6-3 and 6-4 f o r narro+andand broadband emirsiona, respecttvaly.

3.2.2 AC leade. Blectromgnettc enissions s h a l l not appear on AC leads i n excesa of t h e


value8 shown on Pigurea 6-5 and 6-6 for orrrrowband and broadband e d a a i o n r # respectively.

3.2.3 Interconnecting leads.

3.2.3.1 Connected o u t e r s h i e l d and twisted p a l m together. Fo'oi interconnectlag controi .


and s t g n h l lea& having t h e outer ahleld connected, and for twisted pairs wtth the p a i b
.together, e b c t r o o a g n e t l c &iseLona shall not appair on t h e .leads i n a c e r a of t h e value6
shown on Pigurea 6-3 and 6-4 f o r ~ r r a w b a n dand broadbad emiaaione, respectively.

3.2.3.2 Disconnected outer shield and twiated p a i n aeparated. For interconnecttng


c o n t r o l and a i g n a l leada having t h e outer shield disconnected, and f o r twfsted pat- having
t h e p a i r s separated, t h e l i m i t s s h a l l ba dewloped on a caae-by-caoe baala considering t h e
i n t e n t i o n a l transrieaion, its spsciEied power level, necearary i d o m a t t o n bandwidth, and
pulse r t s e ti-. Such U d t s muet ba approved by tlls ~ & n d o r q e n c y concerned. . ,

4. CEO6 (limited a p p l i c a b t l i t y )

4.1 CEO6 applicability. This requirement l a appllcable f o r those equipment and aubayatems
d t h antenns leads o r thoee designed t o be co~lractedt o anteruraa. The t r a n s a t t t e r keptown
harmonic and spurious emieaion portion8 of t h i s requiretmnt may be m e ~ u r e dw i n g t h e procedures
i n RE03 ( i n Ziao of thoae of CBO6) with t h e approval of t h e CaP.d o r agency concerned, &n
any of t h e following conditions e r i a t : (a) t r a n e d t t e c power erceede 5 kU average, (b) t h e
fundamental Lrequancy OF t h e t a r t #ample excaads 1.24 GEE, (c) t h e test sample18 antenna is an
i n t e g r a l p a r t of t h e t r a w d t t e r and cannot ba replaced by a a u i t a b l e dumy load, o r (d) f o r
equipment and euboystem with uavegutde transmission U n a s and operating below 1.24 CIIz. The
frequency range of this requiresent is dependent on t h e operating frequency of t h e temt s ~ p l e
(eee MIL-SID-462). The t r a n a r i t t e r ( k e y - d m ) portion of t h i s requirement is not applicable
within e i t h e r t h e t e a t aamplela neceaaary bandwidth o r 2 5 percent of the fundaaental freqmncy.
4.2 CB06 l i d t s . Conducted e d s a i o u i n excess of the values given below s h a l l not
appear a t t h e t e e t . e e r p l e l a a n t e n d teroinala.

4.2.1 Receivers.

a. Narrowband e d s s i o n e : 34 d~ VV
b. Broadband embeiolle; 40 dB pV/WRz
Downloaded from http://www.everyspec.com

4.2.2 b a n d t t e r r (key-up and atandby).


a. Narrowband emimione: 34 dB pV

b. Broadband emisaione: 40 d l pV/UHz


4.2.3 t r a n m i t t e r r (by-doen model. Ramonica, except t h e r e w n d and t h i r d , and all

The recond and t h i r d harmonica a h a l l be auppreeaed by: SO + 10 log P (where P peak powr,
i n watto, a t t h e fundammtal) o r 80 dB, whichever r q u i r a a l a o r euppreerion.
-
o t h e r rpurioue emfrrione r h a l l h a m peak powarr 80 dB down from t h e power a t t h e fundamental.

5.1 CSOl applicability. Thin requirement i o applicable t o equipment and aubsyatem AC


and DC paver leada, including grounde and neutralo which a r e not grouhdcd i a t a r u a l l y t o the
equipment o r rubmyatem. The requirement i a not appliceble within +
5 percent of t h e p o w r
frequeucy(iem). Thin requirel~antr a y be deleted f o r AC leadr, with t h e approval of t h e Coaund
o r agency concerned, i f no c i r c u i t within t h e equipment o r eyoten h a a r e n s i t i r i t y of 100 mV
o r better.

5.2 CSOl limita. The t e a t aample a h a l l not e x h i b i t any permanent ~ l f u n c t l o n ,degradation


of p e r f o r ~ n c e ,o r deviation from apecified indications, beyond t h e tolerancar i a d i c e t c d i n t h e
individual equipment o r rubsyatem rpecification, when subjected t o electro.llgnetic energy
i n j e c t e d onto i t a power leada lean than o r equal t o t h e valuer ahom i n Figure 6-7. The require-
ment i a a100 met under the following condition: when t h e power roarce apacified i n H I L - M 6 2 ,
adJuated t o dissipate 50 m t t a i n a 0.5 o h load, cannot develop t h e requLred voltage a t tho
t e a t rample power input t e m i m l r , and t h e t e a t eaaple i a not r u r c e p t i b l e t o t h e output of t b
a i g n a l source.

6. m 2 (limited a p p l i c a b i l i t y )

6.1 CSO2 applicability. Applicatioaa of t h l r requirerrant a r e t o be d e t e r m i n d on a


case-bysclee boeir. Uhen epecified, t h i n r e q u i c u e n t i a applicable t o e q u i w n t and a u b y s t e o
AC and DC pomr leada, including ground. and neutrals which are not grounded i n t e r n a l l y t o t h e
equipment o r rubayatem.

6.2 CSO2 l h i t a . The t a t sample a h a l l not e x h i b i t any malfunction, degradation of


perf ormance, o r deviation from apecif i e d indicationr, beyond t h e t o l e r a r e o indicated i n t h e
individual equipment o r a u b s y a t a r p e c i f i c a t i o n , uben rubjected t o I - v o l t from a SO ohm aource.
Tha t e a t a i g n a l a h a l l be applied d i r e c t l y t o t h e equipment input terminals, not through the
test aamplel. power l i n e cord. The requirerent ir a l e o met under t h e f'olloving eonditionr
when a I-watt source of 50 ohm impedance cannot develop t h e required voltage a t t h e test
sample povet input terminale, and the t e a t rampla i e not ouaceptible t o t h e output of t h e
mignal aource.
7. CS03 (limited a p p l i c a b i l i t y )
7.1 a 0 3 applicability. Thie requirement i a applicable t o receiving equipmnt and
r u b y a t e m , much cu receiverr, RP a q l i f i e r a , traneceiverr, and t b a like. The applicable
frequency range of t h i n requirement i e dependent on t h e operating frequency of the t e a t eampla.
aa r p e c i f i e d i n HIL-STD-462.
7.2 CS03 limita. The t e e t aample e h a l l not e x b i b l t any i n t e n m d u l a t i o n products from two
aignala, beyond thooe permitted i n t h e individual equipment o r aubayrtea r p e c i f i c a t i o n , when:

, a. Signal generator I1 i r n e t 66 dB above t h e lapel required t o obtain t h e


atandard reference output, a8 apecified i n MIL--62; except t h a t when f 1
i e i n t h e frequency range of e i t h s r 200 t o 400 IPIs o r 2 t o 25 Hth, the
generator output .hall be 80 dB above t h e reference l e v e l , but t h e output
of t h e aignal generator a h a l l not exceed LO dl..

b. Signal generator 1 2 i e set 66 dB above t h e l e v e l required t o obtain t h e


standard reference output, a 8 .pacified i n HIL-STD-462, but t h e generator
l e v e l e h a l l not exceed a power level of 10 dB.
Downloaded from http://www.everyspec.com

8. CS04 ( l i d t e d applicability)

8.1 CS04 applicability. t h i n requiremeat i s applicable t o receiving squipmnt and


aubsyateno, ouch cur receivara, RF amplifiers,, tran8ceiveras and the like. The applicable
frequency range of thin requiremat ia.dependenc on the operating frequency of the t e a t aample,
ae epecified i n iUL-9R)-462. . .
8.2 CS04 limlta. The t e a t ample aha11 not exhfbit any undesired rarponae when subjected
t o the t e a t signal ahowa on Figure 6-8.

9. CS05 ( l i d t e d applicability)

9.1 a 0 5 applicabilitr. . M e requirement i e applicable t o k c e i v i n g equipment a d


aubyat-, au'ch aa receivera, BI amplifiers, transceivers, and the like. Tha applicable
frequency rmge of t h i s requirement l a dependent on the operating frequency of the t e a t .ample,
as apeciEied I n ML-81D-462.

9.2 CS05 l l n i t a . The t e a t ample ahall not exhibit, due to c r w a modulation, any
nlfunction, denadatioh of performance, o r deviation from apecified indicatima, beyond the
toler-u indicated i n the individual equipment o r aubya tu apeci fication, when subjected
t o t h e f o l l o d n g from eignal generator I2: a aignal 66 dB above the level required to obtain
tha atandard reference ootput, ae epedEied i n MIL-STQ-462, but not t o exceed a parer output
lev01 of 10 d h .

and
10.1 CS06 applicabilir . Thin requirawnt l a applicable to equipment and subsystem AC
power U a , i n c l u d i ~ p o u & . a n dn e u t r a h whhh a n not grounded internally to t h e
equipmnt o r eubayatea.
10.2 @06 limits. The test simple e h a l l not exhibit any malEmction, degr+iatioa of
performance, o r daviatiou from apecified indications, beyond the tolerance8 indicated I n tha
individual eqaipmeat o r eubsyatem epecificatioa, when the test apike ,having tha vaveforr
ehom on Figure 6-9 i e applied to tha AC and DC pomr input Leada f o r a period of not lean
than 1 d n u t e a t each p h e poaition a d f o r a t o t a l t e a t period a a t exceeding 15 minute8 i n
duration (in l l e u . o f the values i n llIbSTQ-462). The values of BO aod t ( ) a r e g l u n below.
The apike a h a l l be euperiqmsed on the powa~linevoltage waveform.

a. Spike I 1 B1 - 400 Volta; t l * 5 dcroaeconda + 20%.


11. C607 (limited applicability)

11.1 -7 avplicability. Thin requirement i e applicable f o r receiving aquipmnt and


subrystem f i c h u t i l i z e e q d c h circuitad

11.2.1 R.yirement 1. The q u e l c h d r c u f t a shall not open when the output of a S + o b


impedance Smpu e g e ~ r a t o r ,a a t a t 90 dB pV/Hb, ie applied and oatched to'the input t a m i a a l a
of the t e a t a&pla.
11.2.2 rement 2. ~ h boqrwlch
. d r c u i t e h a l l not oped aheq two aigarta a r e applied
a t the i n p t =e tat a m e . OI a i m 1 ahall' be an ummdulated UP a I p U 1 a t the receiver
tuned frequsocy, whore emplituda l a two-third8 of tha W voltage ueed t o adjuet the uqueleh.
threrbold. The aecmd ai(pra1 r h d l be an iapulee a l g a l of '50 dl) pV/Rtli.
12. . CS09 (limited applicability)
12.1 CS09 apvlicabiU . Thia requirement is applicable.ta equipment a d aubysteme
t h a t have an operating f r e q z c y angi of 100 kUs o r I r a and an operating u v i t i r i t y of 1pV
o t lean, such w 0.5 VV.
12.2 CS09 lidt. ihs t e a t e&le ahall not exhibit any malfunction, degradation of
p i f o r ~ s n c e ,o r deviation from a p c l f i c d indicatiom, beyond the tolarancea indicated i n the
individual a q u i p m t o r aubaystm a p d f i c a t i o n , when aubjekted t o the levela 1eaa'than.or '
equal 'to thoae e h m on Figure. 6-10 eeroao the applicable t w t points.
Downloaded from http://www.everyspec.com

' 13. CSlO (limited a p p l i c a b i l i t y )

13.1 CSlO a p p l i c a b i l i t .
This electrGIlyFatic p d a e (BW) requiremnt i a applicable t o
Navy equipment and rubsyetemLinterface pins a d t e n i u h of lead., including groundr and
neuttala, connected t o t a d buoya, t r a i l i n g devices, and periscopes. Applications of t h i r .
requirement a r e t o be d e t e r d n e d on a case-by-caae baais.

13.2 CS10 l i m t t . The t e a t rumple a h a l l not exhibit any permanent m l f m c t i o n , degrsdation


of perforrpnca, o r deviation from specified indicationr, beyond t h e t o l e r a n c w and recovery
timer indicated i n the individual equipment o r a u b r y a t u apecificatlon, a f t e r being rubjected
t o a t a t r i g o a l having e t t h e r t h e waveform and c-Q mode current l e v e l shown on Figure 6-11,
ru, determined i n accordance with 1(ILS1D-462.

14. CSll (limited a p p l i c a b i l i t y )

14.1 CSll a m l i c a b i l i t y . Thie IMP requirement i r applicable to Navy equipaent and rub-
ayrtanr having intatconnecting o r intraconneeting control, r i g n a l , o r pouer cable8 connected
t o toued/tralling dovicar and periacoper. Actual cable t y p o , a k a a m d configurations
rubjected t o t h e rpeeifted RS05 l e v e l r a r e exempt froa m e t i n g thLa requiremnt.

14.2 CSll l i m i t . The test sample a h a l l not e x h i b t t any peraanent malfunction, dogredation
of parformance, o r deviation from r p e c i f i e d i n d i c a t i k a , beyond t h e tolerances and recovery
t l w a indicated i n t h e equipment o r 8ubrgstem specification, a f t e r being subjected t o a test
r i g m l having t h e waveform rhown i n Figure 6-12 and haviag a maxiaatr bulk comma mode cable
currant of 10 q r , a r determined i n accordance with NIL-STO-462.

15.1 RE01 applicability. This requiremnt i r applicable f o r radiated e d a a i o m f l e a


equtpaent and eubayatemr, cables (including control, pulre, IF, power, a d antennau traru-
miasSon l i n w ) and intercomacting wiring of tho test sample. The requireaent hpplier a t t h e
fundamental frequeneiea and a l l epurious eaissionr, including harmonica, but d o a not apply t o
r a d i a t Lon from antennas.
15.2 RE01 l i m t t . h g n e t l c f i e l d - e a i a r i o n e shall not be radiated i n excess of the l e v e l r
s h w on Figure 6-13. 1 C th. r e q u i r e m n t cannot be met even with equipaent modifications,
the magnetic f i e l d level-vemus-diatance fal1offa.rhalL be determiued, and t h e d a t a r u b d t t e d
i n t h e gllI Teat laport.

16.1 ILBO2 a p p l i c a b i l i t r . Thie requirement i r applicable f o r radiated emiaaiona from


equipaent nnd subsystems, cables (including control, pulse, IF, power, and antenrua t r a n r
miaaioa l i n e r ) aud interconnecting a i r i n g of the tart aalple. For narrowband, i t appliea e t
t h e fundamental frequeneias and a11 apurioua emiaslonr, including harmonica, but does a o t
apply t o radiation from anteanar. T h L requiraaent is applicable E r a 14 ktlz t o 1 GBr, except
a s noted below:
a. For sonar equipment, narrowb.nd and broedband e d a r i o n requiremnta
a t e applicable up t o 75 MIX.

b, For e l e c t r i c a l equipment, narrowband and broadband emission require-


manta a r e applicable up t o 400 IM+.

16.2 ILBO2 l l l i t r . E-field eaia8iona a h a 1 not be radiated i n excess of thore given i n


16.2.1 and 16.2.2. Above 30 CHt, the lidts a h a l l be m t f o r both horizontally and v e r t i c a l l y
polarized waves.
16.2.1 Narrovband e l e c t r i c f i e l d e d s s i o n a . Ilarrowband B - f i d d e r i r a i o ~s b a l l not be
radiated i n etccea of t h e lidt curve ahom on Figure 6-14 a t the required t o a t distance, a8
n p e d f i e d i n MIkSTD-462.
16.2.2 Broadband e l e c t r i c f i e l d d a a i o l u . Broadband 8-field w i e a l o ~Cram a11
equipment and aubsptem8, including radiated awitchiag transients r e s u l t i n g froa: (1)
autoamtic c y c l i w of e l e c t r o n i c o r e l e c t r i c a l awitching c i r c u i t r y , (2) actcution of purh-
to-talk mchanieme (that i a , keying of t r a n s a i t t e m ) , o r (3) manual awitching a h a l l not be
radiated i n e x c u e of t h e l i m i t curva ahown on Plgura 6-15 a t t h e required t a o t dietancoo,
a. apacified i n UIL-STD-462.
Downloaded from http://www.everyspec.com

17. RE03 ( l f d t e d applicability)

l7. I .-BE03 adplicabflity- Tide r&tir-~ i e applikable, with the-.epipr&vd~of the


pmcuting.activity, vhen the epurioue eaiseioas,e$d harplonice cannot b s . d e t e r J n e d u s h g the
procedures of fX06. The frequency r a g e of t h i a rkquirement i a depe'*t on the operating
frequency of t h e . t e e t .simple (use m-STD-462). Tqe requiremat tu not applicable wtthin
.+
e i t h e r the tedt eample'e neceseary bandwidth o r 5 patcent of the fuadamntal frequincy.

17.2 BE03 l i m i t . &armnice, except the eecond and third, and a l l other opuriour

-
,

erLeeions e h a l l have peak powere 80 dB down from t h s power a t tha fundanental. The eecond
end t h i r d harmnice e h a l l be suppressed by: 50 + LO log. P (where P peak.pover, i n watts,
a t the fundamental) o r 80 dB, vhichemer requiree leee eupprgaeion.
. .
18. us01 . . .

18.1 BSOl applicability. M e requirement applieo t o equipment and etabeyetella a N their


aeeociated cabling and connectotr.

18.2 8501 Wt. The t e e t eample e h a l l not exhibit any ralfuoction, degradation of
performace, o r deviation from epecified indicetione, beyond the tolerancea indicated i n t h e
individual equipaent o r eubeyetem .specification, when eubjected t o magnetic Eielde l e e e . t b n
o r equal t o the limit curve. shown on Figure 6-16..

19.1 BS02. applicability. Parta I and I1 of t h i e r e q u l r k n t a r e applicable f o r :!A and


DC equ1-t and eubryethacr procured for use on s u w r i n e e .

f9.2 8502 l i d t e .

-
19.2.1 Part I epikee.. Tbe t e e t eumple e l u l l not exhibit any maltmetion, degradation
of perfofoatye, o r deviation from epecified fndicatione, beyond the tolerancea indicated i n
th individual equipment o r subsyatca epecificatfon, when eubjected t o the tc4t .spike haviag
ehom on Figure 6-9.
the ~ e f o r m The values of and to
a r e given belov:

-
19.2.2 P a r t I1 pover'frequency. The t e e t eample e h a l l not exbibit any ~ l f u a c t i o a ,
degradation of perforaance, o r deviation f r o s . e p e d f i e d indicatione, .beyond the t o h r a n c a e
indicated i n the individual equipmot o r aubsystea r p e c i f i ~ t i o n , when 20 m r e e a r e applied
to t h s test wfre a t 60 and 400 Hz.

between 14 k b and 1 QU.


.
20.1 .RS03 a p p l i c a b i l i t
hfn. This requirement i e applicable f o r all equipmnt and r u b y e t -
1 G t k , t h i e r e q u i r w n t is not m n b t o r y m l r s otheruiae
required by *e procuring activity.
20.2 BSO3 U n i t e . The t e e t e&le e h a l l not exhibit any d P u n c t i o a , d e g r d a t i o n of '
perforaaaee, o r deviation from epecified indicatfone, beyond the tolerances indicated L o t h e
iadividual equipment o r eubeyetem epecffication, whea eubjected t o the radiated e l e c t r i c
f i e l d l w e than o r equal t o thoee epecified herein. Above 30 Itllr, the r e q u i t a n t e h a l l k
rat t o r both horixontally and vertically polarired m e ; c i r c u l a r polarired wavae a m a l s o
acceptable. Appropriate consideration e h a l l be given t o the operational radiated electro-
q n e t l c environment from both friendly and hoetile e n i t t a r e which an e q u i w n t o r eubsyetam
may encounter during i t e l i f e cyele. Applicable portfow of IUGBbDK-235 e b l l be used t o
determine the anticipated e13vironment. Ib ' a a i d a m , equipacnt a d e u b r y a t a r are t o met thin
requirement when rubjected t o a f i e l d of 1 volt/rater f r a 14 Uk t o 1 Gllr. If level8 comparable
t o thoee .in ML-tlDBK-235 are epeciPied, m d i f i c a t i o M t o the procedure i n MIL-STD-462 m y ba
required.. Such modif icationa a r e t o be described in. the EM1 Teat Plan.
Downloaded from http://www.everyspec.com

21.1 US05 applicability. Thia BNP r e q u i t a n t 18 intended f o r Navy equipment and


s u b y a t m and is applicable hen both of tha follovlng conditione a d o t : (a) operation of
the equipmnt or a u b o p t m l a eaaential f o r the soceesa of a d a a i o u and (b) tho equipmat o r
rubryatem in i a t d e d t o be operated external t o tha h u l l of a rubastino, including priacopea.
Cablor that can not be tutd l a accordance with KXL-SXD-462 obnll neet the requlrmenLI of

.
CS11, and cablam subjected to the specified C811 level8 a m exempt from meeting t h i r
requinaent
21.2 RSOS l i m i t . The.te8t .ample o h 1 1 not exhibit any permauent malfmctlon, degradation
of perfotunce, o r deviation from opac1fied iadicrtiona, beyond the toleraucam and r e c o n q
t h e indicated i n tb iadividsel equipment or oubsyatem specification, a f t e r k i n g subjected
t o a tent oigaal having the waveform and amplitude ohom i n Figure 6-17.
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com

Limit

f o = Receiver tuned frequency o r band c e n t e r f o r a m p l i f i e r r .

El - Lowert tunable frequency of r e c e i v e r bend i n use o r t h e lowest frequency


of amplifier parrband.

f2 = Bighert tunable frequency of r e c e i v e r bad i n u r e o r the h i g h e s t frequency


of amplifier parrband.
-
.

U Bandwidth between the 80 dB p o i n t r of the r e c e i v e r r e l e c t i v i t y curve a r defined


i n the t e a t rample'r t e c h n i c a l r e q u i r e m n t r o r t h e c o n t r o l plan.

.1'.. The l i m i t a t A i s 80 dB above t h e input l e v e l required t o produce t h e rtandard


reference output. (Thia l i m i t r h a l l not be w e d f o r a m p l i f i e r r )
t i . - T h e l i d t a t B r h a l l b e r e t a r followe:
a. Rcceiverr: 0 dBm applied d i r e c t l y t o tbe r e c e i v e r i n p u t temioalr.
b. Ampllfier~: The limit rhall be a r rpecified i n t h e t a r t rample'r technical
requirement or c o n t r o l plan. If oo l i m i t i r defined i n the above docuacnta,
t h e 0 dBm value r h a l l be ured.

FIGURE 6-8. LIMIT FOR CS04


Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com

c.
fj lo.
5
0

.ol .1
..
1. 10. . .100.

Frequency (MHz)

' IPm (1) a 1.0~1


MAX
e a 1)1~(2nft)
. .

w-, . .
. . . . . . Ipli( (t) t common mode pln
. . , . : cw8nl hmpa

FIGURE 6-H. UMlT FOR CS10


Downloaded from http://www.everyspec.com

Frequency (MHz)

--nft
(11 a I.osIwe SlN(2m)

whore,

ICABLE
(t) 8 comma mode coble
c w m t b omps
f = frquency, hertz

O = docoy Factor

.FIGURE 6-12. LIMIT FOR CS11


6-20
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com

E ,-- FlEio STRENGTH IN KILOVOLT/ METER


tr 3 RISETIME IN SEC. . . .
i d =DURATION PULSE WIDTH IN SEC.
' '
, t i a FALNIME IN SEC,

' ' FIGURE


. . 647. UMIT FOR RS05 . . ,

. .
Downloaded from http://www.everyspec.com

Part 7.' Aacillary or Support Equipment


and Subystemm I n s t a l l e d i n b n - C r i t i c a l
Ground Areas (Class 1)
Downloaded from http://www.everyspec.com

Paragraph 1. SaOPI
1.1 Datermining requirements
1.1.1 Air Force and Wavy procutewnte
1.1.2 Axmy procurements

CEO3
CW3 a p p l i c a b i l i t y .
CEO3 limits
M: and interwnnecting control leadm
AC leads
Air Force procurements
Navy procurement@
Interconnecting s i g n a l leads

CBa6 ( I l r i t e d appl+xbillty)
CE06 a p p l i c a b i l i t y
CE06 l i m i t e
Beceiverp
T r a m d t t e r s (key-up a d rtaadty)
Transmittem (key-dotm mode) ,

(limit& a p p l i c a b i l i t y )
CB07 applicab+ty
CEO7 L i m i t s . . . ..

CSOl (limited .applicability) .. .


CSOl .applicability
CSOl l i d t e

C802- (limited a p p l i & b i l i t y ) ' .


C802 a p p l l c a b i l i t y
CSO2lidts. .
. .
CS03 (lhit+l applicab~tp) .
csO3 a p p l i c a b i l i t y
CS03 lidts

CSO? (limited applicability)


cS04 a p p l i c a b i l i t y .,
CS04 l i d t e .

C805 (limited a p p l l a b F U t y )
OW5 a p p l i c a b i l i t y
CS65 limits

a06
CSO6 a p p l i c a b i l i t y .
csO6 lilits

BgOZ
BBO2 a p p l i c a b i l i t ~
m 2 limits
kirrowbant electet* f i e l d e d r a i o n e
Broadband e l e c t r i c f i e l d a i r l r i o l u

-3 ( l i d t e d applicability)
RE03 a p p l t c a b i l i t y
RB03 l i m i t , . .
8502 (limited a p p l l c a b i l i t y )
US02 a p p l i c a b i l i t y
8502 l i d t e
--
P a r t I apikee
P a r t XI power frequency
Downloaded from http://www.everyspec.com

Part 7
m 3
11503 a p p l i c a b i l i t y
RSO3 l l d t a

Bateelon and ~ u e c e p t l b l l l t yrequirements f o r


clamm B q u l p m n t aod rubryetan

Limit for CEO3 narrovbuad mlerlonm DC (Navy


and M r Force), i n t e r c o n n e c t l ~control l e d e
(Navy only) and &C lead8 (At? Force only)
L i n i t f o r 0 3 broadbod laisrione, DC (Navy
and Air Force). i a t e r c o a n c t i n g control lead.
(Wavy only) and AC leads (Alr Oorce only)
L h l t f o r CEO3 narrovbrnd dmrionm AC lead.
(Wav only)
-it f o r CB03 broedbnd ealreioru AC l a d e
(Navy only)
U n i t f o r CSOl
L M t f o r cso4
Acceptable vavemhpee f o r CSO6 and US02
Limit f o r RE02 ~ r r o u b . 0 demisrioru
liait f o r RE02 brodbaod e d s e i o n r
Downloaded from http://www.everyspec.com

This part of HItSlD-461 suppleaento Part 1 oE the standard by defining emission and
pueceptibility requiremanta and l i m i t s f o r e w i m n t i d aubsyste.s which support the class A
equipment and mbsystem, but which will not be physically located i n c r i t i c a l s o u n d areas
(claas 8 ) . &amplea of some of the clans B equipmant, and eubeyeteaa include: electronic shop
kainteuance and tiet equipment used i n x y ~ c r i t i c a lground areaa; andtheodolitea, navaids,
and o t h e r eimilar equipment and subsystems w e d i n w n - c. r i.t l c a l areas.
. :

1.1 Determlnhg requirements.

1.1.1 M r Force and Wavy proeuremeutr. Tabla 7-1 # b a l l be w d t o determine the


requirements applicable f o r equipment and rubaystem procured f o r AF or Navy use. The t a b l e
a l s o denotes the paragraphs wherein t h e requiretmnts and liaLts a r e defined. A "9" e n t r y i n
t h e t a b l e means the requirement i o applicable, and the U n i t s h a l l be rat uring the procedurea
i n MIL-STD-462 o r the apprwed KMI Test Plan. A "YL" entry n e a ~the applicability oE the
requirement is limited end is specified i n the wrresponding appropriate paragraph. Tha l i m i t
shall be met using t h e procedurea Ln I1U-S1D-462 o r the approved g[f t e s t Plan. A "T' entry
k a n a t h a t t h e a p p l i c a b i l i t y of tbe requiraoant must be detarmined on a cane-by-case baain and,
i f the requirerant i s t o be iaposed, i t m u s t be so epecified Ln thc appropriate procurerurt
document. llhan required, t h e l i m i t s h a l l be net using t h e procedures i n MIL--62 o r the
approved EUI Teat Plan. Absence of an entry m w the requireaent,is not -applicable.
e

1.1.2. Army p r o c u m n t s . Thia part of MIL-STlb461 s h a l l not be used unless otherwise


specified by the Commnd o r agency concerned.

.
2.1 CEO3 a p p l i c a b i l i t This reqilirement i d applicable f o r alternating' curreat ( k )
and d i r e c t current (DC) l e a k , .hich obtain p w r f r a o t h e r Bwrcea o r provide pouar t o
;other equipment o r suhayetems; including grounds o r aeutrala which a r e not grounded
Internally t o th a u b y e t e a o r equiplrent being aeaauked. For Navy procurements, t h i s
'

:requirement La also applicable f o r l n ~ ~ r w n ~ c t control


ing leads ohich provide AC and DC
'pover.from o r t o t h e t e s t sample. The.requirement i s not' applicable,for interconnecting
:eigaal 1e.d. such M clock, IF, audio, d i g i t a l , BP, a o d t h q l i k e , unless otherwine specified
'by t h e Command o r agency wlrceme& Cqnduetcrd-switching transient eriseiono, igcludin(~
'OtVf~lrFswitching, s h a l l meet the r e q u i m n t s of CB07.
..
2.2 m 3 limits.
.2.2.1 DC and interconnecting c m t r o l ' l e a d s . Blectro'oegnetic &ssione shall not appaar
'
om DC and, vhere r e q u i r d , i n t e r c q ~ a c t i n gcoatrol lea& ia excesa of the valuw ahown on
' ~ i g u r e s7-1 and 7-2 f o r narrwband and broadband eaisaione, respectively.

2.2.2 AC leads.
2.2.2.1 Air Force procurements. ' Electroleagnetic. emissiow rhnll not appear on AC
leads i n exceea oE.the values ehwn.on Ftgurer 7-& and 7-2 f o r nsrroriband and'broadband
!emissions, rerpactively.

2.2.2.2 Wavy procurenenta. ElectrorleIfnbtfc eniseione e h a l l not appear on AC laada


i n excess of t h e valwa shown on Figures 7-3 and 7-4 f o r narrowband and broadband e a i s s f o w ,
r w p e c t i vely.

2.2.3 Interconnecting aignal lcrds. I f compliance with t h i s requit-nt is required


f o r signel leads, limite s h a l l be developed on a case-by-case basis eonridering th&
intentional transmission, i t 8 e p e d f i e d power lavel, neccrseary hformation bandwidth, and
pulse rise time. Such l i m i t a must be approved by the Commrnd o r agency concerned.

3. -6 ( l i d t e d applicability)

3.1 CB06 applicability. Thfe requiremat is applicable Eor those equipment and sub-
aqstem with antenna leads o r those designed t o be connected t o antermas. -
tranedtter
(kegdown), h a r m a i c and spurious emission portiom of t h i s r q u i r c a e n t may be w u r e d
using t h e procedures i n RSO3 ( i n l i e u of -6) with the approval of the Coaand o r agency
concerned, when any of t h e following wnditione exist: (a) transmitter power exaeede 5 W
average, (b) t h e fundamcntd frequency of the t e a t r ~ p l exceeds
e 1.24 GRo, (c) the t e s t .
sample'a antenna is an i n t e n d part of the t r s ~ s i t t e rand cannot be repleced by a s u i t a b l e
Downloaded from http://www.everyspec.com

TABU 7-1. EhlllmnN AND SUSCEPTIBILITY REQUIREMENTS FOR CLASS


B EQUIPMENT AND SUBSYSTEMS
Downloaded from http://www.everyspec.com

d u ~ yload, o r (dl f o r equipment and r u h y r t a q . d t h wavegufde t r a w r l s s i o n 11.- and operating .


balov 1.24 GB.. The frequency range of t h i s requirement is dependent on t h e operati= frequency
of the t e s t rample~(acre llZGSTD-462). The t r ~ r d t t e r(key-dom) portioa of this requfremnt
b wt applicable wlthin aitber the t e a t reaple'r necearary bandvfdth o r 5 percent of the +
f mQosntal freqiaency.
3.2 CB06 l h f t r . Coaductd emirrions i n cnce8r of t h e valuer given'below a h a l l not
appear a t t h e twt rmaple'r antenha t e r d a a l r .
3.2.1 Receiverr.
a, Narrowband u i s s i m a : 34 dB 'VV
b. Broadband edemlow: 40 d~ ~/mz
3.2.2 Ranemitters ( k e y u p and atandby).
a. Narrowband e d w i o ~ : 34 dB F\P
b. Broadband ~ m l s ~ i o r r r : 40 d b )r9/Ptlr
3.2.3 Tr.zu)litterr (key-dorm mode). .BarmodceS except the second and third, and all othar
spurlour d r r i o n r ahall' have peak powerr 80 dB down frolr the p m t a t the fmdaaental. The '
+
r e e d d thfrd harmonice a h a l l be suppressed by: 50 10 log P (where P peak power, i n
roettr, a t t h e fundamental) o r 80 dB, whichever .requiree . lea8 mppression..
-
4.1 a 0 2 a p p l i c a b i l i t ~ . . A p p l i c a t i o ~of t h i s requiremant a r e t o be datermined on a
cane-hy-caae b8ai.a f o r the following typer.oP lea&; . AC o r DC leads which obtain power from
o r provide power t o other .equip.ent or robmystere.
4.2 Q07 li&tr. ~onductedswitching rpikes of lee& than 50 mictoraicon&'in'duration
r h l l not a g e d t h e following, m applicablal

a. AC l e d r : + 50 percent of n o d u a l rm nrltage.

'be M: l e d e r + 50 percent, -150 percent of n a i n a l ..line' voltage.


Coadncted r d t c h i n g s p i b equal t o or..greater..tbn 50 d c r o r e i d s I n duration ;ball meet thq
truuieat requirements sr r p e d f i e d i n tho individual eqdp.ant . o r eubayrt- ~ d f i c a t i o w .
Spike duration is the . t i r e interval betwean t h e 50% amplitude point on the t r a r u i e a t leading
edge and the 50% amplitude point on. the tr8mi-t t r a i l i n g edge; high frequency r i n g i l e u p e r
Imporad on tbe pulse l&q and t r a i l i n g edges.rhould be ignored. .
5. CSOl .(limited applicability,)
5.1 C901 applicabiliQ. T h i s . r t q d r e o c n t is a p p l i ~ l eto .equipmnt and rubrymtem AC
and .#: power.lea&, i n c l u d l ~wormdr end neotrale which q r r not g o u d e d i n t e r n a l l y t 6 the
equipmbnt o r eubsymtc+ The requitdacbt,ir oat applicable WLWn 5 percant of the p o w
frequang(ieB). For Navy procure~mtk, t h i s r e q u i r M C m y be deleted .for AC leabr, d t h th'e
apprcwa1.ot t h e o r ~ e n r y , c o n e e t a s d ,i f im d r e u l t , w i t h i n the equipment o r
o p t - i.8 more o e w i t i v e than 100 mV. .
5.2 CSOl limit.. The test sapple' r h l l not exhibit m y s a l f m c t i o n ; degradation of
parformnce, o r deviation from rpecif1.d indlcatioar, beyond the t o l e r a ~ c e aindi-ted i n - t h e
i n d i d d u a l equipment o r outmystem specif$catbn; when subjected t o electrorrgretic w r g y
isfected onto ' i t 8 power lea& ,equal so 'the' valtlas on Figure 7-5. The requirerant i r alee rat
under the f o l l d n g coaditlmr. durn the power umrce.rpacifiad i d l I I t 3 1 D 4 6 2 , a d j w t d t o
dirtsipate 50 w a t t s ' h i a 0.5 ohm load, cannot develop the required voltage a t the tat sample
p a n r input tenrinals, a d the t w t raisple i e not swceptlble t o t h e output of tbe r&ndi source.
. .
6.. CSO2 ( l i d t e d applicability)
6.1 CSO2 a ' i l i c a b i l i t
cue-by-came &s tor
.
.ApP1icati-
and mubyatem
of thin rwairement a r e t o be bstermined on a
and II: mr w ,Im+udiq protmdm and
~rqutralewhich.are not grounded l n t e t m l l y t o the e q d p m ~ n tor mubaystem.
Downloaded from http://www.everyspec.com

6.2 C802 limits. Tba t a t mample mhdl not exhibit any emlflmction, degtadation of
parfororaaa, o r doviation from mpecified i W i c a t i o m , beyond tha t o l e r u a e u i a d i u t a d i n the
fndiviCk.1 equipamt o r mrrkyatea mpecifieation, then rubjected t o I-volt frolr a 50 o h
rarrca. The t e a t m I g n r ; l rW1 k applied d i r e c t l y t o tha equipment input terminal., not
through the test raaple'r pouer line cord. ?ha requiresent i r ale0 wt under tho following
coaditiollr Wten a l-tt marc8 of 50 o h fmpednna cannot devalop tho required voltage
a t tha t w t r a p l e power input L O ~ M ~and O the~ toot raaple i m not eudcrptible t o t h e
output of the r i g u i rource.

7.1 CS03 a p p l l c a b i l i t ~ Appliutioer of t h i m raqulrrmnt arm t o bs datetnLned on a


cae~by-caoe b i r for receiving equipment and rubayrteu, ruch a r receiverm, BP a p l i f i e r r ,
t a r c r i r e r r , .ad tho like. The applicable frequency rmge of thim m q u i r c w a t ir: depandent
on the operating ftequnncy of the t a r t sumpla an mpcified i n MIbSTW62.
7.2 CS03 lioltr. t e a t ramp18 a h 1 1 not a r h i b l t any iutermodulation prodoctr f r a
two migmlb, beyond thoea p s t l i t t e d Ln the individual e q u i p a n t o r m u b ~ l t e umpecifiution,
uh4lll
a. SlgnU generator I 1 i r r a t 66 dB above the level required t o obtain the
rtandard r e f e n n c a output, u rpecified i n llIL-SFD-462; except t h a t then f 1
fa i n the frequency r a n p of e i t h a r 200 t o 400 Mix o r 2 t o 25 Wlk, tha
generator output r W l be 80 dB above the reference level, but tho output
of migoal gemrator I 1 a b d l not exceed LO dBa.
b. Signal generator #2 i r r a t 66 dB above tha level required t o obtain the
8t.ab.rd refercaea output, u, rpecified i n ML-SrO-462, but the gaearator
output level rball not axceed a power l e v e l of 10 d h .

8.1 CS04 a m l i c a b i l i t ~ . A p p l i u t i ~of thir requirement a r e t o be deterrined on a


we-by-cue baoir f o r reccivarm, iW amplifiarr, trcurrceiwrr, and tha like. The applicable
frequrncy range of t h i s requiremat i r dependent on the operating frequency of tha t e a t
ample, u m@fied i n I(ILSTD-462.
8.2 CSM lioitr. Toat a m p l e r h l l not exhibit any undeeired reeponee when rubjectad
t o tha t e a t rignal rharrn on Cigure 7-6.
9. CS05 ( l l d t e d applicability)

9.1 CS05 a v p l i c a b i l i t
cucby-eare bash f o r mee4ran.
.
Applicetioar -of t h l m raqrdremnt a r e t o be & t a n i n a d on a
u p l i f i e r r , t r u r c a i n r r , u* t b I-. applicable
frrgwncy range of t h i r requiramnt f a dependent on the operating frequency of the t a r t
rragle, u epocified i n HXIdTD-462.
9.2 CS05 llmltr. The t e a t ruple &all not exhibit, due t o croer modulation, any
mlfuaction, degradation of parfomance, o r deviation from rpeeified indicationr, beyond the
t o l e r a n c a indicated i n tho individual equfpme~nto r rubayotsr rpecificatlan, rkeu r u b j e c t d
t o tb follouiag from rigP.l p w r a t o r I21 8 signal 66 dB above tha lave1 requlrod t o obtain
t h r standard reference output, cu rpseified i n tIIL--62, but not t o exceed 8 power output
lev81 of 10 d k .

10.1 C906 a p p l l c e b i l i t
AC and PC pawor 1 4 , inel&-
. . T h f a r e q u i r q l a applLc8ble t o e q u i p a n t d r u k y r t a
ground. and neutral8 h i c h a m not g r d d i n t e r n a l l y t o
tha equio.6nt o r rubsymtom.
10.2 CSO6 limltr,' The t e a t ample riull not' exbiblt any u l f t m c t i o n , ~ d a t i o oaf
perfotorrre, o r d w b t i o o from apeelfled iodicatioar, beyond the tolerancar indicated i n tbe
individual .qoi$mont o r rubaptem rpeelfication, *ban the twt rplka haring tha wavefora
rhopa on m e 7-7 i r applied t o t h e hC and DC pnnr input h a d 8 f o r a period of not lemr
.than 1 d n u t e a t each phme porition, and f o r a t o t a l t e a t period not a c e e d i w 15'miautem in
duration ( i n limo of the valuea i n HIL--62). 'Ib. valryr of BO and to
a m given belw.

a. Spike I 1 El -
The r p i l u s h a l l be e u p a r l q m e d on the pomrliw voltage waveform.
400 Voltm; ti - 5 mfcrosecoudr 2 20%.
Downloaded from http://www.everyspec.com

11.1 RHO2 applicability. lbia raquiravrnt i a applicable f o r radiated e d s s i o n o f r o a


.equipment and s u b s y s t c a , cables (including codtrol, p+e, IF, power, and antennae t r a m -
: d s s i o n l i o e r ) and i n t e r c o ~ e c t i qwiriqg of t h e t*t'.ss*le; f o r narrwband, i t applieu a t
.the fundamental frequencies and a l l spurioue edssioqs, .$ucluding har.ollia, but does not
apply t o r a d i a t i o n from ante-. lbis i e q u i ~ ' . i appltcable
s f o r broadband d s s i o n r ,
from 14 k8s t o 1 GiIr and f o r narrowband e d a s i o n s f r o a 14;lhk t o 10 CBr.

11.2 PEO2 .limits; & f i e l d +ssiQna shall nO(: ba radiated i n e x c a r of those given
i n 11.2.1 and 11.2.2.' Above 30 Hth, t h e limits s h a l l ' bo met , f o r both h o r l o n t a l l y a d ,
v e r t i c a l l y polarized waves.

11.2.1, Nar&band e l e c t r i c f i e l d emissions. Narrowband B-field emissions shsll ndt


be radiated i n exesscr of the applicable l i m i t .curve 6 6 on P i k e 7-8 a t the' r e q d r e d
t e s t distance, a s s p e c i f i d i n HII.-SR)-462.
. . .
11.2.2 Broadband electric f i e l d arissi-. Broadbapi B-f i e l d emissioos frcir a11
.equip.eot and s u b p t e m s ; including r a d e t e d quitcbing t r a w i e n t a r e s u l t i n g from (a)
-automatic cycling of e l e c t r o n i c o r e l e c t r i c a l switchi- c i r c u i t r y . (b) actuation 6f push-
ito-talk m c h a n i s ~( t h a t i a , keying of transmittere), o r (c) manual muitching a h a l l not
b e radiated i n exceea of t h e Limit curve.shorm on Figure ,7-9 a t t h e required t e s t d i a t m w ,
.aa s p e c i f i e d i n UIL--62. ..
12. 11603 (limited applicability)

12.1 Bg03 k p p l i c a b i l i t g This req+eme!nt i s ' a p p l i c a b l e , w i t h the appqwal of t h e


procuring a c t i v i t y , when t h e spurious m i n i o n s and harmonics cannot be determined ruing t h e
procedures of CB06. The frequency iange of this requ!f-nt i n dependent on the operating
Creqoency of t h e t e s t sample ( s e e . ~ S T W 6 2 ) . TQe r e q u i r v n t i d not applicable within
e i t h e r t h e t e s t saaple's necesiary bandwidth o r 5 5 percent.of t b e f u n d e t a 1 frequency.
. . . .. ,
12.2 BB03 limit. ?Iarrbni&., except tha second and' t h i r d , and . a l l other s p u r i o w
h i s s i o n s a h a l l have ,peak powers 80'dB.dckn fr&n tha poiier a t . the'fundamental. 'Lba second
and t h i r d h a e c a shall be suppressed, bg: 50 + 10 l o g P (where P = peak porrer, ?n watts,
a t t h e fundamental) o r 80 dB, whichever require6 1aqs.buppression.

. .
13.1 8802 avplicabiiity. Appecatioae of P a r t 8 I and I1 of this requireeant a r e t o
be determiaed on a me-by-case, baais. . -
..

-
13.2.1 P a r t I spikes. The t&t sample. shdJ not er;hibit any malfunction, degrada-
t i o n of performnnce, o r deviation. from specified indicatioqs, beyond t h e t o l e m n c u indicated
in t h e individaal equipment o r suFyptem spacificatiqn,:uhen subjected t o t h e t e s t . s p i k e
The v a l w 04 B() and a r e givdn b e l ~ . to
-
having the w~veformshown oh Figure 7-7.

a; Spika #I
. .
El 400 Volts; cl - 5 microeecon& + 20%.
13.2.2. P a r t 11 -' mWer freqiitircr. The test @amples h ' d l .not 'axhibit ulf~mctbn,
degradation of pertormadrca, o r deviat&on from specified i n d i c a t i o w , b e y o d the tolerances
indicated i n t h e individual equipmnt 'or subsyetam specification, when 20 amperes a r e applied
t o t b a teat w i r a . a t t b e power Ereq-nCy(i+) of t ~ ' t w t ' s a b 1 e .
. .

14.1' 8803 a p l i c a b i l i t y . lhie requirement is applicable f i r dl .quipmdt'* 'subwst-


between 14 d P 10 G l a . Above 10 G b , t h i s requir-nt. .is not mandaton unless o t h l n i 8 .
required by t h e procuriug a c t i v i t y . .
..I .
14.2 .IS03 limits. 'Zhe teet sample s h d l not .exhibit &y.mdfunction, d e g r d a t i a q of
perfor~lsnce,o r daviation from s p e c i f i e d indicatiooe, beyond t h e tolerances indicated i n
t h e i n d i v i d u d eqnipment or,qubsystem s p e c i f i c a t i a , when.aubjectad t o - a radiated e l e c t r i c
f i e l d of 1 Volt/meter. .Above 30 ?I& t 6 c;' r e q S - t s h a l l be met f o r both borinontally
'

and v e r t i c a l l y polarized w m e ; c i r c u l i r .polarized 'waves . r e a l e o acceptable.


Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com

FIGURE 7-2. UMlT FOR CEO3 BROADBAND EMISSIONS, DC


'

(NAVY AND AIR FORCE),INTERCONNECTING CONTROL


LEADS (NAVY ONLY) ANDAC LEADS (AIR FORCE ONLY)
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com

41 I V . . I w
fo f2 f

- Receiver tuned 'frequency. o r band center .for..ampli fierr .


fo
f1 '. - of amplifier paee'band .
.

Loweet tunable frequency of rece4vei band i n .use o r t h e lowest frequency

f2 - Bi6hest tunable frequenCy of receiver band i n uae o r t h e highest Ereqkncy


of amplifier passband.

W - . Bandwldth.between the 8 0 . d ~points


. of the receiver s e l e c t i v i t y curve a s . defined
i n the t e e t eample ' 8 technical tequlrtments o r t.he control plan.

1 The li'dt a t &.fa 80 dB above the input l e v e l r e q ~ r & t o . produce the standard
r e f e r t u b output.. (Tbir I h i t r h a i l n 0 t . b used' f'or amplifiers)
2. T h e . l i i i t a t B..shall be a e t ' a r followr:.. ..'
a. Receivers: 0 dB@applied d i r e c t l y to the k c e i v e r i n ~ terminals. t
b. h p l i t i e r s : The l i m f t a h a i l ,be as specified i n t h e t e e t rample'a technical
requirement o r control plan. If a o . l i d t is d k f i n e d - i n the above documeotr,
the 0 dBm value s h a l l be hoed.

FIGURE 7-6. LIMIT.'FOR CS04


j-11
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com

Part 8 . Tacticcol and Special Purposa


Vehicles ood Engine-Drivca .Equipment
( C h a s Cl)
Downloaded from http://www.everyspec.com

Part 8
Paragraph 1.
llaprr-
Craup I
Oraup I1
Group I1 item with electronic eqdpent,
mbilo talephoeao or corsraicatiom
Crarp 111
-
Graun 1x1 i t e m with electroaic equiprcnt,
-~ ~

lobile teleph~neaor c o u ~ u n i c a t i o ~
Croup I , Croup 11, and Group 111 i t e m with
electronic oeming a d control circuitry
WD3
UW)3 a p p l u b i U t y
1RQ3 lirlts
Ihdi.ted d r r i o m
Radiated susceptibility

8-1 lioit for UHO3 broadband cmlmiocu


8-2 Limit for W 3 aarroubaud eatiaaioni~
Downloaded from http://www.everyspec.com

Thin part of WILSTD-461 supplements Part 1 of t h h s t a d d a d by defining enlrsion a d


susceptibilitfr reguiremnts and l i d t r for t a c t i c a l and e p e d a l purpoee oehiclJ a d engine-
dkiven equiprent (class Cl). Ancillary equipment intended f o r use on theme vehiclw shall
&et the applicable requiremum of other parts of t h i s document.

The following reqdrtments apply f o r the group af tacticel and spacia? purpose vehicles
and enginedri-n eqdplaetlt defined i n Tabla 8-1.
2.1 Group I. Group I irema shall comply with UH03 over the f requeney range of 150 kEz
t o 1000 m.
2.2 Group If. Group I1 i t e m s h a l l comply with WHO3 over the limited frequency range of
1.5 t o 400 Mir, except that cor~lnercialgeneral-purpo8e and construction Group If it- procured
for w e solely La non-critical areas e y be exempt from. WHO3 when rpeclfied by the CoP.and o r
e g - q concerned.

2.2.1 Group I1 item with eiecttonic equipment, -bile telephoaas or a m u d c a t i o w .


h e n alectronic eauiment. w b i l e talephones or commicationo are t o ba iaatalled i n Group X I
dt-, incl;ding u&d i a non-criiical a r e u , additi-1 8111 suppreaaion is required. Tkie
supprension s h a l l bs provided i n a k i t t o ba iastalled by the urer and ahall i ~ u d e i w t a l l a t l o n
cbmpomnte, parts, and imtructions necessary f o r suppreoeing the ignition, windshield wiper,
brake and signal lights, siren, and so forth, so aa t o result i n compliance with U11)3..
2.3 Group III. Group X I 1 it- shall,w e t t h e reqdremnte of SAB ,1551.
2.3.1 Ggoup rII itens with electronic equipment. -bile talephone& or coamtcations.
dhsn alectroaic equipmkint, mobile telepbonea or coaunicationo are t o be i w t a l l e d i n Group 111
i t e m , including thoae ueed in non-critical.araar, additional IPII' euppreosion is required. This
eupprerrion s h a l l be prwided i n a k i t to be inetalled by the user and s h a l l include installation
eomponentr, parts, and ilutructioas necessary f o r suppressing the ignition, dndshiald.wiper,
brake and signal Ughta, eiren; and s o forth. lhis suppression k i t , when iaotalled, shall r-alt
i n compliance with M 3 .

2.4 Oroup I; Group X I , and Group I f f i t e m with electronic sonoin# cLwi control circuitry.
Tactical and special purpoee vehicles and engin+iven e q u i p m t u t i l i d q electroalc sewing
apd coatrol d r c u i t r y shall, wben mquired by the C m n d o r agency coacerned, m e t the radiated
susceptibility requirement of U11)3, i n addltian t o tba applicable raquircosnts i n 2.1, 2.2, and
2.3. See 8AB:AIR 1425 f o r aethoda of acbieviii E W ia gas turbine engine a c c e s s o r i ~ .

3.1 fW)3 applicability. UL103 applies to tactical 604 .pedal purpose vehicles and engine-
driven equipmeut, includiw the e l e c t r i c a l equfpmnt and parts i w t d l e d thereon.

3.2.1 Radiated adssione. K-field broadbad narrowband edssiotm r h a l l not be radiated


$a excoma of the l e v e b rham on Figures 8-1 end 8-2 reapectimly a t the required t e a t distance,
am specified i n MIL-STD-462 for the 'applicable f reqyncy r a w of the raqufrewnt. Ahme 30 m,
the limit shall be m t for, bath horlmntally a d verrically polarised waves; fie radtated emfarion
L i m i t s h a l l be rst utilizing the procedur- of RBOZ of MIL-STD-462 o r an apprwed BllI .teat plaa.
. .
3.2.2 Radiated suiceptibility. Group I, Ctaup 11, and &oup fI1 it- required by 2.4 t o
m e t tlrie requirement s h a l l not ezhibit any aalftmctioa, degr&latton of perforulrce, o r Aviation
fron specif ied indications, beyoad the t o l e r a n c ~indicated i n tba i n d i v i b l specif ieatians,
wheu subjected t o t h e following rqdiated E - f i d & io .the frequency range of 2 tins t o 10 GBz:

kt f o r both horizontally and vertically polarized waves;


Above 30 M E z , the requirement s h d l be
{ircular polarized vaves are also acceptable. The radiated suseeptibllity lialt s h a l l be met by
!tilizing the procedures of BS03 of KIL-STD-462 o r an apprwed BllI t w t plan.
Downloaded from http://www.everyspec.com

TABLE 8-1. GROUPINGS OF CLASS CI VEHICLES AND EQUIPMENT

. . GROUP 11 GROUP 113:


1 Crash rescue trucks , Hotorc yc l es Sedatrs
I
.

Wveeled vcl~lcles, tactical ' Harbor tugs Stiff cars

I Armored and track vehicles


-
Off the-road 'cargo carr icrs
. Fork-l if t trucks
Outboard motors
Delivery trucks
Moving vans
Armored personnel carr iers Floodlight t r a i l e r s h b u 1 ances

I Assault and l andi ng c r a f t Cargo load l n g and handling equipment Cargo trucks
Amphibious vehicles ~ngine-driven a i r conditioners Fire trucks
Patrol b0at.s Maintenance and service trucks/vans .Other similar administrative
vellicles wh~cha r e basically
Gun motor carr iages civi l i an in nature
Railway maintenance-of-way Earth augers
equ i pmen t
I Storm boats
Genera l purpose and construct ion
equipment ( i .e., cranes, bulldozers,
heaters (gasoline and water), ditch

I Heaters, gas01 ins

Rep1 ace~nentengines for all


diggers, a i r compressors, cement
loaders, concrete mixer, pumps,
blowers, et'c.
of the above Replacement engines for a l l of the
above
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com

Part 9. Engine Generatom and Aueoeiated Components.,


Unintarruptlble Pover Sate (UPS), end Mobile Electric
Parer (HBP) Kquipment Supplying Pawr To or Uaed i n
Critical Arom (Closa C2)
Downloaded from http://www.everyspec.com

Part 9
Paragraph I.
ILEqa1-s
Clara C2 it- with porrsr output ratiqga ( 240
kilovolt mpersr (kVA)
C h r C2 items with power output rating6 > 240 kVA
Bwaa germratore wlth electronic circuitry
UlDM
-4 .pplicability
rmO4 l i d t n
Conducted d r r i o n u
Badiatad emiraiom
Radiated rurceptibility

FIGURBS
9-1 L i m i t for UW04 conducted cniaaionm
9-2 L i m i t for LIMO4 radiated eaiaaionr
Downloaded from http://www.everyspec.com

p a r t of WILSTD-461 aupplerentq Part 1 of t h i s a t a n d a d b y d s f i n i q . d a s l a and


~ w e p t i b i l f t yr e q u i r e m a a d limits for.engine g+&tora a d rfsociated CoIpoaqntm,
,
tmlnterroptibla potrar beta (UPS) a d +bile e l e c t r i c pomr . (W) quiplant aspplylog potFar
t o o r wed i n criticd areas (clasa.C2)..

The f o l l o d n g r a q u l m n t s . apply f o r d a r n C2 items.


. .

2.1 Claaa C2 i t e a r d t h power oirtput.ratiaga </ 240 U l o v o l t amname (~vA). A 1 1 chiao


CZ item with power output ratiaga 5 240 kVA a l u l l wet tbe corducted and radiated d s s i o n
reauiremaats of U W (with the radiated emIraion requiremeats applicable a t a dfatanca of
1 Peter).
2.2 claea c2 it- with power outpi~tratingm > 240 kVA. A l l c b a s C2 iceme with
power output ratings > 2 4 0 W h s h a l l lreat,the radiated emteaion r e q u i r e s n t a of rmO4 ( a t a
'dlatanca of 1 m t e r ) , when s p e d f i a d by the C o d o r agency concemcd.
2.3 Engine generators with electronic circuitrjl. Engine geaeratora g p l o y l n g e l e c t r o n i c
'circuitry f o r iegulation o r control, o r aeta with a a p l i f t e r s f o r electr&cally controlling
regulation, tempexature, freqwnw, atabil$ty, and so forth, aha11 met the radiated s u s c e p
t f b i l i t y requirement of UkXl4, i n addition t o the appUcable requiramaata i n 2.1, a d 2.2.

3.1 IllPM a ~ ~ l i c a b i l i t y .UHO4 appll? t o e n g i genaratora


~ and reqociated eoipo'mnta,
UPS, and HBP equipment supplying powar'to o r wed i n c r i t i c a l arena.

3.2.1 Conducted e d $ s i ~ . Broadband eLectromagnetic e d a a i o w - .h.lL not appear on t h e


pawer lead. i n excwa of t h e levele ahovn'on Figure 9-1. The brohdband conducted edaaiona
llrit a h a l l not k exceaded over the frequency range .of .01S to.50 MEs, rrhea manured uslag
the approprfate procedure of Ht~-ST&462 o r an approved : ENI t e a t plan.
.. . .
. .
3.2.2 h a t e d . d a s i o ~ . Broadband electr-atic. e d a a i o t ~s~h a l l not be 'radiated
i n axceaa of the l e a shorn on Figute'9-2 a t t l C r e q u i r e d tent distcmce. Above 30 Mlk,
the L i d t shall be m e t f o r both h6rizontally and m i t i c a l l y polartred waves. The broadbard
radiated edeaiocu limit a h a l l not bk exceeded'uhen'.saeured tming the procadutea of RE02
of lKI~SfD-462o r an a p p r h e d BICL: teat! plan..

3.2.3 Radiated s w c e ~ t i b i l l t y . &gi+ genrratora required by 2.3 t o meet t h L


requirement a h a l l not exhibit any ' m l f u i ~ c t ~ o ndegradation
, of parformaaca,-.or deviation Prom
.epecified ladieatlone, bayond the. tolerani& indicated la the individual equipmant e p e d f i -
cation, when a u b j e c t d t o t h e klLov+g: radiated B-fields in tha frequency rang0 o f 2 lltlr
t o 10 GUS, u t i l i a i n g t h e proceduraa of.;RS03 of llItrSm-462 o r an approved BIT t e a t p u n . ,
..
I . . .

Above 30 ME=, th r o q o i r w n t e h l l bn 'etfo? both h6rizoqtally .nd v e r t i c a l l y polarized


waves; c i r c u l a r polarized wavw ore a l s o acceptable. .
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com

Part 10. C q r r c i a l Electrical a d


B l e c t r o n c b a n i ~ lEquiplent ( C h 8 C3)
Downloaded from http://www.everyspec.com

Part 10
SCOPE
REQUIREMENTS
Group I
Croup I i t e m with electronic ~ 8 t l L n gand
control c i r c u i t q
Group I iteur wed in aon-critied areas
Croup I1
Group I11

w5
WHO5 applicability
uno5 limits
Cducted d a a i o m
Rdiated e m i r s ~ w
Radiated owceptibili ty

TABLE

10-1 Groupiaga of class C3 equipment

10-1 lirit for OW5 conducted e r L l r i o ~


10-2 L i d t for t W 5 r d h t e d crluions
10-3 Wt tor OW5 narrowband emireions
Downloaded from http://www.everyspec.com

Tbim part of UTL-STD-461 eupplementr Part. 1, 5. and 6 of t h e rtrndard by defining emirrion


requiremonte and l i d t r f o r c a r r c i a l e l e c t r i c a l and electromechanical equipment and r u b y e t e u .

The foll&n# r e q u i r a r n t e apply f o r tho g r o u p of comuercial e l e c t r i c a l aad electromechadcal


equipment defined i n Table lbI.
,
2.1 Croup I. Except ae noted i n 2.1.1 a l l Group I item s h a l l meet t h e conducted and
radiated emiarion requirenmnta of UL105. Except f o r portable e l e c t r i c tool., Group I equipmnt
intended f o r uee aboard r h i p r rball meet t h e applicable require-ntr of e t t h e r P a r t 5 o r P a r t 6
of t h i a document.
2.1.1 .Group I it- wlth e l e c t r o n i c ranring and c o n t r o l c i r c u i t q . , Commercial e l e c t r i c a l
and electromchanical equiprent and a u b n y r t w u t i l i z i n g e l e c t r o a i c r e a i r y awl cdsrtrol c i r c u i t r y
~ h r l l .ahan required by t h o CaaPand o r agency concerned, m e t t h e radiated ~ w c e p t i b i l i t yrequire-
-t .of. -5, l n addition t o t h e .applicable requtrementa i n 2.1.
2.1.2 Group I i t e m ured i n n o u - c r i t i c a l arear. Group I item# procured f o r ure r o l e l y i n
non-critical arena a r e exempt from'the e d r a i o n and r u e c e p t i b i l i t y r e q u l r m n t r of t h i e rtandard.
2.2 Group 11. Group 11 it- are exempt Prom t h e d e r i o n requiremanta of t h i a rtaadard
u n l m r otherwire rpecified by t h e Command o r agcacy concerned. Ilouever, t h e r e equipment a h a l l
dimplay a L a k l o r sign with t h e f o l l o v i ~wording:

DO NO1 OPBRkTII WITHIN 30 m


RS (LOO WBT) OF BLBCPKONIC
EQUIPkBUT OR SUBSYmBnS OR ASSOCIATED ANZWNA.9

2.3 Croup 111. Croup I11 iterr a r a exampler of e l e c t r i c a l and electrorechanical e q u i p w n t


which a r e w u a l l y i n t e r f e r w c e f r e e and f o r which w r i t t e n approval t o forego emiarion t u r t i a g
m y be obtained when procured o r i n d i v i d u a l ' e q u i p s n t . As a memr of eatabltabing whether a n
equipaent w i l l require L u t i n g , t h e equipment arnufacturer aha11 forward t o t h e Command or'agency
c o n c o r d a complete e l e c t r i c a l d e s c r i p t i o n of the equipment and t h e j u r c i f i c a t i o n t o . f o r e g o
turting. Wrttten approval .to' forago t e a t i a g mu8t k obtained from t h e Coaand o r agency concerned
end rhall ba rcquelted a# e a r l y i n t h e procurevlnt cycle r e poarible.

3.1 U W S applicability. 111105 appliee t o a11 Group I cooaarcial e l e c t r i c a l and electro-


mechanical eqdpnent procured f o r use i n c r i t i c a l areae.

3.2.1 Cmducted e d e e i a r u . ~ i o d b a n delectromagnetic arieeione elm11 not appear on t h e


power lea& .in t h e frequency range o f , 50 kHs t o 50 lOts i n e r c e r r . o L the l e v e l 8 shorn on Figure
10-1. The broadband conducted e d a a i o ~lidt shall not be exceeded over t h e frequency range of
.05 t o 5 0 )Ms when measured wing t h e CB procedure of MftSTD462 o r an approved Blll t e a t plan.

'3.2.2 Radiated emfaaionr. B r d b a n d aid narrowband e l e c t r o a q p e t i c eriaeionr a h a l l not be


r a d i a t e d i n t h e frequency range of 150 kB. t o 400 lPls i n a x c u r of t b e applicable l i m i t curver
r h w n on t f g u r e r 10-2 and 10-3 reepectively, *en neaeured a t t h e required t u r t d i e t a n c e u
apecified i n EIIL-9-62. The broadband and lurrwband radiated eaiariona l i m i t e h a l l bd r t
u t i l i z i n 8 t h e procedures of BBO2 of MIIrSTD-462 o r an approved 1W t m t plan.

3.2.3 Radiated eueceptibility., Group 1 i t e m required by 2.1.1 'to meet t b i r requirement


aha11 not e x h i b i t any n l f u n c t i o n , dagradation of perforrince. o r deviation f r c a a p e c i f i e d
indicatioor. beyond thd: toleranccr i n d i c a t e d i n t h e i n d i v i d u a l e p e c i f i c a t i o a , rhea rubjacted t o
t h e following radiated E-fialda i n t h e frequency range of .15 lIRr t o 400 @ax
Frequency itange
. I S t o 400 m
Above 30 ~lils, t h e requirement r b a l l be m e t f o r both horizontally and v e r t i c a l l y polarfrcd waver;
c i r c u l a r polarized wavee a r e a l s o acceptable. The radiated r u e c e p t i b i l i t y lidt r h a l l be m t by
u t i l l t i a g t h e proceduras of RS03 of Wn-Sm-462 o r an approved BHI t e a t plan.
Downloaded from http://www.everyspec.com

TABLE 10-1. GROUPINGS OF CLASSCS EQUIPMENTS


GROUP I: ' GROUP XI1

Portable e l e c t r i c t o o l s , both double i n s u l a t e d .Machine and semt-portable t o o l s , Inherently interference-free


and metal case,.such a s sabre save, d r l l l a , such as l a t h e s , r i n g g r i n d e r r , items, such' as;
impact wrenches, r i v e t guns, nut d r i v e r s a d welders ,'a tamping p r e s s e s a d
so forth. s o forth.
Repair and maintenance shop equipment 1 Arc welders Antennas, passive
I
~ a c i l i t i e sequipment i n s t a l l e d i n b u i l k u g s Engine' generators used f o r c o n t r o l l e r , motor manual
o r a t s i t e s such a s a i r conditioners, generators, construction o r shop support (except those using e l e c t r o n i c
elevators, exhaust f a n s components)

Cubicle, power

Reperforators D i s t r i b u t i o n Network , passive V)

Projectors and f l a s h u n i t s Incandescent Lighting F i x t u r e

Heaters ( a l l types) Main Line Switch

Lithographic and photoprocessing equipment Hotor, induction.

Battery chargers Panel, welding

Fixed garrison type k i t c h e n and c o d s s a r y Regulator, passive element l i n e


equipmnts . .
s t a r t e r , & t o r , msnuaa I
Off i c e equipment
SwLtchboard , power 1
Vending machines

Laundry and d m cleaning equipments


Transformer used below e a t u r a t i o n
level

Voltme t e r
I
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com
Downloaded from http://www.everyspec.com