Lenovo System x3650 M4 HD Installation and Service Guide: Machine Type: 5460
Lenovo System x3650 M4 HD Installation and Service Guide: Machine Type: 5460
Before using this information and the product it supports, read the general information in Appendix D
“Getting help and technical assistance” on page 1135, Appendix E “Notices” on page 1139, the Warranty
Information document, and the Safety Information and Environmental Notices and User Guide documents on
the Lenovo Documentation CD.
LIMITED AND RESTRICTED RIGHTS NOTICE: If data or software is delivered pursuant to a General Services
Administration “GSA” contract, use, reproduction, or disclosure is subject to restrictions set forth in Contract No.
GS-35F-05925.
Contents
Ennen kuin asennat tämän tuotteen, lue turvaohjeet kohdasta Safety Information.
Safety statements
These statements provide the caution and danger information that is used in this documentation.
Important: Each caution and danger statement in this documentation is labeled with a number. This number
is used to cross reference an English-language caution or danger statement with translated versions of the
caution or danger statement in the Safety Information document.
For example, if a caution statement is labeled Statement 1, translations for that caution statement are in the
Safety Information document under Statement 1.
Be sure to read all caution and danger statements in this documentation before you perform the procedures.
Read any additional safety information that comes with your system or optional device before you install
the device.
Statement 1
DANGER
To Connect: To Disconnect:
1. Turn everything OFF. 1. Turn everything OFF.
2. First, attach all cables to devices. 2. First, remove power cords from outlet.
3. Attach signal cables to connectors. 3. Remove signal cables from connectors.
4. Attach power cords to outlet. 4. Remove all cables from devices.
5. Turn device ON.
Statement 2
CAUTION:
When replacing the lithium battery, use only Part Number 33F8354 or an equivalent type battery
recommended by the manufacturer. If your system has a module containing a lithium battery, replace
it only with the same module type made by the same manufacturer. The battery contains lithium and
can explode if not properly used, handled, or disposed of.
Do not:
• Throw or immerse into water
• Heat to more than 100°C (212°F)
• Repair or disassemble
Statement 3
CAUTION:
When laser products (such as CD-ROMs, DVD drives, fiber optic devices, or transmitters) are
installed, note the following:
• Do not remove the covers. Removing the covers of the laser product could result in exposure to
hazardous laser radiation. There are no serviceable parts inside the device.
• Use of controls or adjustments or performance of procedures other than those specified herein
might result in hazardous radiation exposure.
Some laser products contain an embedded Class 3A or Class 3B laser diode. Note the following.
Laser radiation when open. Do not stare into the beam, do not view directly with optical
instruments, and avoid direct exposure to the beam.
Statement 4
Statement 5
CAUTION:
The power control button on the device and the power switch on the power supply do not turn off
the electrical current supplied to the device. The device also might have more than one power
cord. To remove all electrical current from the device, ensure that all power cords are disconnected
from the power source.
2
1
CAUTION:
If you install a strain-relief bracket option over the end of the power cord that is connected to the
device, you must connect the other end of the power cord to an easily accessible power source.
Statement 8
CAUTION:
Never remove the cover on a power supply or any part that has the following label attached.
Hazardous voltage, current, and energy levels are present inside any component that has this label
attached. There are no serviceable parts inside these components. If you suspect a problem with
one of these parts, contact a service technician.
Statement 12
CAUTION:
The following label indicates a hot surface nearby.
Statement 26
CAUTION:
Do not place any object on top of rack-mounted devices.
CAUTION:
Hazardous moving parts are nearby.
DANGER
In addition to the instructions in Chapter 2 “Installing optional devices” on page 25 for installing optional
hardware devices, updating firmware and device drivers, and completing the installation, Business Partners
must also complete the steps in “Instructions for Business Partners” on page 25.
The Lenovo System x3650 M4 HD server is a 2U-high1 rack model server for high-volume network
transaction processing. This high-performance, multicore server is ideally suited for networking environments
that require superior microprocessor performance, input/output (I/O) flexibility, and high manageability.
Performance, ease of use, reliability, and expansion capabilities were key considerations in the design of
the server. These design features make it possible for you to customize the system hardware to meet your
needs today and provide flexible expansion capabilities for the future.
The server comes with a limited warranty. For information about the terms of the warranty, see the Warranty
Information document that comes with the server.
The server contains X-Architecture technologies, which help increase performance and reliability. For more
information, see “What your server offers” on page 12 and “Reliability, availability, and serviceability”
on page 15.
You can obtain up-to-date information about the server and other Lenovo server products at
http://shop.lenovo.com/us/ en/systems/. At http://www.ibm.com/support/mysupport/, you can create a
personalized support page by identifying Lenovo products that are of interest to you. From this personalized
page, you can subscribe to weekly email notifications about new technical documents, search for information
and downloads, and access various administrative services.
If you participate in the Lenovo client reference program, you can share information about your
use of technology, best practices, and innovative solutions; build a professional network; and gain
visibility for your business. For more information about the Lenovo client reference program, see
http://www.ibm.com/ibm/clientreference/.
The server comes with either 2.5-inch hard disk drive bays nor 1.8-inch solid state drive bays. Some models
come with two 2.5-inch hard disk drive bays on the rear of the server.
Note: The illustrations in this document might differ slightly from your model.
The following illustration shows a server with 2.5-inch SAS/SATA hot-swap hard disk drive bays.
1. Racks are marked in vertical increments of 1.75 inches each. Each increment is referred to as a unit, or a “U”. A
1-U-high device is approximately 1.75 inches tall.
Bay 24 Bay 25
000
00
000
0000000
000
00
000
000
000
000
0000000
000
000
000
0000000 0000000
00
000
000
000
00
00
000
00
The following illustration shows a server with sixteen 2.5-inch SAS/SATA hot-swap hard disk drive bays and
sixteen 1.8-inch solid state drive bays.
00000 00000
00000 00000
00000 00000
00000 00000
Figure 3. Front view: 2.5-inch hot-swap hard disk drive and 1.8-inch solid state drive model
The drive ID for each bay is printed on the server front, above each bay.
If firmware and documentation updates are available, you can download them from the Lenovo website. The
server might have features that are not described in the documentation that comes with the server, and
the documentation might be updated occasionally to include information about those features, or technical
updates might be available to provide additional information that is not included in the server documentation.
To check for updates, go to http://www.lenovo.com/support.
The model number and serial number are on the ID label on the front of the server, as shown in the following
illustration.
Note: The illustrations in this document might differ slightly from your hardware.
Figure 4. ID label
In addition, the system service label, which is on the cover of the server, provides a QR code for mobile
access to service information. You can scan the QR code using a QR code reader and scanner with a mobile
device and get quick access to the Lenovo Service Information website. The Lenovo Service Information
website provides additional information for parts installation and replacement videos, and error codes
for server support.
Figure 5. QR code
You can download an Lenovo ServerGuide Setup and Installation CD to help you configure the hardware,
install device drivers, and install the operating system.
For a list of supported optional devices for the server, see http://www.lenovo.com/ serverproven/.
The Documentation Browser automatically detects the regional settings in use in your server and displays
the documents in the language for that region (if available). If a document is not available in the language for
that region, the English-language version is displayed.
Select the server from the Product menu. The Available Topics list displays all the documents for the
server. Some documents might be in folders. A plus sign (+) indicates each folder or document that has
additional documents under it. Click the plus sign to display the additional documents.
When you select a document, a description of the document is displayed under Topic Description. To select
more than one document, press and hold the Ctrl key while you select the documents. Click View to view
the selected document or documents in Acrobat Reader or xpdf. If you selected more than one document,
all the selected documents are opened in Acrobat Reader or xpdf.
To search all the documents, type a word or word string in the Search field and click Search. The
documents in which the word or word string appears are listed in order of the most occurrences. Click a
document to view it, and press Crtl+F to use the Acrobat search function, or press Alt+F to use the xpdf
search function within the document.
Click Help for detailed information about using the Documentation Browser.
Related documentation
This Installation and Service Guide contains general information about the server including how to set up and
cable the server, how to install supported optional devices, how to configure the server, and information to
help you solve problems yourself and information for service technicians. The following documentation also
comes with the server:
• Environmental Notices and User Guide
This document is in PDF format on the Lenovo Documentation CD. It contains translated environmental
notices.
• Lenovo License Agreement for Machine Code
This document is in PDF format on the Lenovo Documentation CD. It provides translated versions of the
Lenovo License Agreement for Machine Code for your product.
• Important Notices
Depending on the server model, additional documentation might be included on the Lenovo Documentation
CD.
The ToolsCenter for System x and BladeCenter is an online information center that contains information
about tools for updating, managing, and deploying firmware, device drivers, and operating systems. The
ToolsCenter for System x and BladeCenter is at http://publib.boulder.ibm.com/infocenter/toolsctr/v1r0/.
The server might have features that are not described in the documentation that you received with the
server. The documentation might be updated occasionally to include information about those features, or
technical updates might be available to provide additional information that is not included in the server
documentation. These updates are available from the Lenovo website. To check for updates, go to
http://www.lenovo.com/support.
The following information is a summary of the features and specifications of the server. Depending on the
model, some features might not be available, or some specifications might not apply.
Notes:
• Use the Setup utility to determine the type and speed of the microprocessors in the server
• For a list of supported microprocessors, see http://www.lenovo.com/ serverproven/.
Memory:
• Minimum: 2 GB
• Maximum: 768 GB
– 64 GB using unbuffered DIMMs (UDIMMs)
– 384 GB using registered DIMMs (RDIMMs)
– 768 GB using load reduction DIMMs (LRDIMMs)
• Type:
– PC3-8500 (DDR3-1066), PC3-10600 (DDR3-1333), PC3-12800 (DDR3-1600), or PC3-14900
(DDR3-1866)
– Single-rank, dual-rank, or quad-rank
– Unbuffered DIMM (UDIMM), registered DIMM (RDIMM), or load reduced DIMM (LRDIMM)
• Slots: 24 dual inline
• Supports (depending on the model):
– 4 GB UDIMM
– 2 GB, 4 GB, 8 GB, and 16 GB RDIMMs
– 32 GB LRDIMM
Integrated functions:
• Integrated Management Module II (IMM2), which consolidates multiple management functions in a
single chip.
• Intel I350AM4 Quad Port Gigabit Ethernet controller with Wake on LAN support
• Universal Serial Bus (USB) ports
– Front (optional): two ports (supported when the video and USB breakout cable is installed)
– Rear: four ports
– Internal: one port for Hypervisor USB key
Attention: As a general consideration, do not mix standard 512-byte and advanced 4-KB format drives
in the same RAID array because it might lead to potential performance issues.
PCI expansion slots (depending on your model):
Notes:
• Power supplies in the server must be with the same power rating or wattage.
Hot-swap fans:
Server on
• Maximum altitude: 3,050 m (10,000 ft), 5°C to 28°C (41°F to 82°F)
Attention:
– Design to ASHRAE Class A3, Temperature: 36°C - 40°C (96.8°F - 104°F) with relaxed support:
– Support cloud like workload with no performance degradation acceptable (Turbo-Off).
– Under no circumstance, can any combination of worst case workload and configuration result
in system shutdown or design exposure at 40°C.
– The worst case workload (such as Linpack, Turbo-On) may have performance degradation.
• Temperature:
– 5°C to 40°C (41°F to 104°F)
– Altitude: 0 to 950 m (3,117 ft); decrease the maximum system temperature by 1°C for every
175-m increase in altitude.
• Humidity:
– Non-condensing: -12°C dew point (10.4°F)
– Relative humidity: 8% to 85%
• Maximum dew point: 24°C (75°F)
• Maximum rate of temperature change:
– Hard disk drives: 20°C/hr (68°F/hr)
Environment:
Server off:
• Temperature: 5°C to 45°C (41°F to 113°F)
• Relative humidity: 8% to 85%
• Maximum dew point: 27°C (80.6°F)
Storage (non-operating):
• Temperature: 1°C to 60°C (33.8°F to 140.0°F)
• Maximum altitude: 3,050 m (10,000 ft)
• Relative humidity: 5% to 80%
• Maximum dew point: 29°C (84.2°F)
Shipment (non-operating):
• Temperature: -40°C to 60°C (-40°F to 140.0°F)
• Maximum altitude: 10,700 m (35,105 ft)
• Relative humidity: 5% to 100%
• Maximum dew point: 29°C (84.2°F)
Particulate contamination: airborne particulates and reactive gases acting alone or in combination
with other environmental factors such as humidity or temperature might pose a risk to the server. For
information about the limits for particulates and gases, see “Particulate contamination” on page 1141.
Heat output:
Notes:
1. Power consumption and heat output vary depending on the number and type of optional features
installed and the power-management optional features in use.
2. The noise emission level stated is the declared (upper limit) sound power level, in bels, for a random
sample of machines. All measurements are made in accordance with ISO 7779 and reported in
conformance with ISO 9296. Actual sound-pressure levels in a given location might exceed the average
values stated because of room reflections and other nearby noise sources. The noise emission level
stated in the declared (upper limit) sound-power level, in bels, for a random sample of system.
Note: You cannot mix different wattages of power supplies in the server.
• ServeRAID support
The ServeRAID adapter provides hardware redundant array of independent disks (RAID) support to
create configurations. The standard RAID adapter provides RAID levels 0, 1, and 10. An optional RAID
adapter is available for purchase.
• Systems-management capabilities
The server comes with an integrated management module II (IMM2). When the IMM is used with the
systems-management software that comes with the server, you can manage the functions of the server
locally and remotely. The IMM also provides system monitoring, event recording, and network alert
capability. The systems-management connector on the rear of the server is dedicated to the IMM. The
dedicated systems-management connector provides additional security by physically separating the
Note: The server does not support DOS (Disk Operating System).
• VMware ESXi embedded hypervisor
An optional USB flash device with VMware ESXi embedded hypervisor software is available for purchase.
Hypervisor is virtualization software that enables multiple operating systems to run on a host system
at the same time. The USB embedded hypervisor flash device can be installed in the internal USB
connector. For more information about using the embedded hypervisor, see “Using the embedded
hypervisor” on page 113.
Systems Director
Systems Director is a platform-management foundation that streamlines the way you manage physical
and virtual systems supports multiple operating systems and virtualization technologies in Lenovo and
non-Lenovo x86 platforms.
Through a single user interface, Systems Director provides consistent views for viewing managed systems,
determining how these systems relate to one other, and identifying their statuses, helping to correlate
technical resources with business needs. A set of common tasks that are included with Systems Director
provides many of the core capabilities that are required for basic management, which means instant
out-of-the-box business value. The common tasks include the following items:
• Discovery
• Inventory
• Configuration
• System health
The Systems Director Web and command-line interfaces provide a consistent interface that is focused
on driving these common tasks and capabilities:
• Discovering, navigating, and visualizing systems on the network with the detailed inventory and
relationships to the other network resources
• Notifying users of problems that occur on systems and the ability to isolate the sources of the problems
• Notifying users when systems need updates and distributing and installing updates on a schedule
• Analyzing real-time data for systems and setting critical thresholds that notify the administrator of
emerging problems
• Configuring settings of a single system and creating a configuration plan that can apply those settings to
multiple systems
• Updating installed plug-ins to add new features and functions to the base capabilities
• Managing the life cycles of virtual resources
For the locations of other LEDs on the system board, see “System-board LEDs” on page 31.
Front view
The following illustrations show the controls, LEDs, and connectors on the front of your server model.
Rack Rack
release 2.5-inch hard disk drive bays release
latch latch
Operator 0000
00000 00000
00000 00000
00000 00000
00000 00000
Rack Rack
release 2.5-inch hard disk 1.8-inch solid state release
latch drive bays drive bays latch
Figure 7. Front view: 2.5-inch hard-disk-drive bay and 1.8-inch solid-state-drive bay model
• Rack release latches: Press the latches on each front side of the server to remove the server from the
rack.
• Hard disk drive activity LEDs: This LED is used on hot-swap hard disk drives. Each hot-swap hard disk
drive has an activity LED, and when this LED is flashing, it indicates that the drive is in use.
• Hard disk drive status LEDs: This LED is used on hot-swap hard disk drives. When this LED is lit, it
indicates that the drive has failed. If an optional ServeRAID controller is installed in the server, when this
LED is flashing slowly (one flash per second), it indicates that the drive is being rebuilt. When the LED is
flashing rapidly (three flashes per second), it indicates that the controller is identifying the drive.
• Operator information panel: This panel contains controls and LEDs that provide information about the
status of the server. For information about the controls and LEDs on the operator information panel, see
“Operator information panel” on page 19.
• Tag: Pull the tag forward to access the tag.
• Video and USB breakout connector: Connect the video and USB breakout cable to this connector (see
“Video and USB breakout cable” on page 19 for more information).
• Video connector (optional): Connect a monitor to this connector. The video connectors on the front and
rear of the server can be used simultaneously.
Use the video and USB breakout cable to connect external I/O devices to the server. The video and USB
breakout cable connects through the video and USB breakout connector (see “Front view” on page 17). The
video and USB breakout cable has connectors for a display device (video) and two USB connectors for
a USB keyboard and mouse.
The following illustration shows the connectors and components on the video and USB breakout cable.
Captive screws
Power-control button/
power-on LED
1 2 3 4
• Power-control button and power-on LED: Press this button to turn the server on and off manually.
The states of the power-on LED are as follows:
Off: Power is not present or the power supply, or the LED itself has failed.
Flashing rapidly (4 times per second): The server is turned off and is not ready to be turned on. The
power-control button is disabled. This will last approximately 5 to 10 seconds.
Notes:
1. Depending on the type of operator information panel installed in your server, the Reset button is on
the operator information panel or the light path diagnostics panel.
2. You do not have to pull out the operator information panel to obtain more information if there's no
release latch existed in your server model.
Rear view
The following illustration shows the connectors on the rear of the server.
Shared system
management
Network connectors
Drive bay 24 Drive bay 25 (with optional adapter) Power supply 2
000
00
000
0000000
000
00
000
000
000
000
0000000
000
000
000
0000000 0000000
00
000
000
000
00
00
000
00
• NMI button: Press this button to force a nonmaskable interrupt to the microprocessor. It allows you to
blue screen the server and take a memory dump (use this button only when directed by the Lenovo
service support). You might have to use a pen or the end of a straightened paper clip to press the button.
The NMI button is in the lower left-hand corner on the rear of the server.
• Power connector: Connect the power cord to this connector.
Note: Power supply 1 is the default/primary power supply. If power supply 1 fails, you must replace it
immediately.
The following illustration shows the LEDs on the rear of the server.
AC power
LED (green)
DC power
000
00
000
0000000
000
00
000
000
000
0000000
000
LED (green)
000
000
000
Power-supply
0000000 0000000
00
000
000
000
000
Note: Power supply 1 is the default/primary power supply. If power supply 1 fails, you must replace
the power supply immediately.
• Power-on LED: When this LED is lit and not flashing, it indicates that the server is turned on. The states
of the power-on LED are as follows:
Off: Power is not present, or the power supply or the LED itself has failed.
Flashing rapidly (4 times per second): The server is turned off and is not ready to be turned on. The
power-control button is disabled. This will last approximately 5 to 10 seconds.
Flashing slowly (once per second): The server is turned off and is ready to be turned on. You can
press the power-control button to turn on the server.
Lit: The server is turned on.
• System-locator LED: Use this LED to visually locate the server among other servers. You can use
Systems Director or IMM2 web interface to light this LED remotely.
• System-error LED: When this LED is lit, it indicates that a system error has occurred. An LED on the light
path diagnostics panel is also lit to help isolate the error.
The power-on LED flashes to indicate that the server is connected to an ac power source but is not turned on.
Approximately 5 seconds after the server is connected to power, one or more fans might start running to
provide cooling while the server is connected to power and the power-on button LED will blink quickly.
Notes:
1. When 4 GB or more of memory (physical or logical) is installed, some memory is reserved for various
system resources and is unavailable to the operating system. The amount of memory that is reserved
for system resources depends on the operating system, the configuration of the server, and the
configured PCI options.
2. Ethernet 1 connector supports Wake on LAN feature.
3. When you turn on the server with the graphical adapters installed, the Lenovo logo displays on the
screen after approximately 3 minutes. This is normal operation while the system loads.
When you turn off the server and leave it connected to power, the server can respond to requests to the
service processor, such as a remote request to turn on the server. While the server remains connected to
power, one or more fans might continue to run. To remove all power from the server, you must disconnect it
from the power source.
Some operating systems require an orderly shutdown before you turn off the server. See your
operating-system documentation for information about shutting down the operating system.
Statement 5
CAUTION:
The power control button on the device and the power switch on the power supply do not turn off
the electrical current supplied to the device. The device also might have more than one power
cord. To remove all electrical current from the device, ensure that all power cords are disconnected
from the power source.
2
1
The server can be turned off in any of the following ways:
• You can turn off the server from the operating system, if your operating system supports this feature. After
an orderly shutdown of the operating system, the server will turn off automatically.
Note: When you install any PCI adapter, the power cords must be disconnected from the power source
before you remove the PCI Express riser-card assembly and the PCI-X riser-card assembly. Otherwise,
the Wake on LAN feature might not work.
• The integrated management module II (IMM2) can turn off the server as an automatic response to a
critical system failure.
In addition to the instructions in this chapter for installing optional hardware devices, updating the firmware
and device drivers, and completing the installation, Business Partners must also complete the steps in
“Instructions for Business Partners” on page 25.
Important: To help ensure that the devices that you install work correctly and do not introduce problems,
observe the following precautions:
1. Make sure that the server and the installed firmware levels support the devices that you are installing.
If necessary, update the UEFI and IMM firmware and any other firmware that is stored on the system
board. For information about where firmware is stored in the server, see “Updating the firmware” on page
99. For a list of supported optional devices for the server, see http://www.lenovo.com/ serverproven/.
2. Use the best practices to apply current firmware and device-driver updates for the server and
optional devices. To download the “System x Firmware Update Best Practices” document, go
to www.ibm.com/support/entry/portal/docdisplay?lndocid=MIGR-5082923&brandind=5000008.
Additional hints and tips are available from the following sites:
• Lenovo support: http://www.lenovo.com/support
• System x configuration tools: http://shop.lenovo.com/us/ en/systems/server-library/
#comboFilters[category]=.Tools
3. Before you install optional hardware devices, make sure that the server is working correctly. Start the
server and make sure that the operating system starts, if an operating system is installed, or that a
19990305 error code is displayed, indicating that an operating system was not found but the server
is otherwise working correctly. If the server is not working correctly, see “Running the DSA Preboot
diagnostic programs” on page 139 for information about how to run diagnostics.
4. Follow the installation procedures in this chapter and use the correct tools. Incorrectly installed devices
can cause system failure because of damaged pins in sockets or connectors, loose cabling, or loose
components.
1. After you have confirmed that the server starts correctly and recognizes the newly installed devices and
that no error LEDs are lit, run the Dynamic System Analysis (DSA) stress test. For information about
using DSA, see “Dynamic System Analysis” on page 137.
2. Shut down and restart the server multiple times to ensure that the server is correctly configured and
functions correctly with the newly installed devices.
3. Save the DSA log as a file and send it to Lenovo. For information about transferring data and logs, see
“How to send DSA data” on page 1136.
4. To ship the server, repackage it in the original undamaged packing material and observe Lenovo
procedures for shipping.
Before you send diagnostic data to Lenovo, read the terms of use at http://www.ibm.com/de/support/
ecurep/terms.html.
You can use any of the following methods to send diagnostic data to Lenovo:
• Standard upload:
http://www.ibm.com/de/support/ ecurep/send_http.html
• Standard upload with the system serial number:
http://www.ecurep.ibm.com/app/ upload_hw
• Secure upload:
http://www.ibm.com/de/support/ ecurep/send_http.html#secure
• Secure upload with the system serial number:
https://www.ecurep.ibm.com/ app/upload_hw
Server components
The following illustration shows the major components in the server.
The illustrations in this document might differ slightly from your hardware.
00000000
00000000
00000000
00000000
0000
0000
0000
0000
00
0000
00
00000
00000
00000
ServeRAID battery 0
Heat sink
Fan
Microprocessor installation tool
Microprocessor
DIMM
Fan bracket
System board
Hot-swap HDD
backplane
Safety cover
Power-supply filler
panel
Power paddle card
Expander 0
00
00
Power supply
Chassis
panel 000
000
Bezel
2.5-inch hard-disk drive
Blue on a component indicates touch points, where you can grip the component to remove it from or install
it in the server, open or close a latch, and so on.
Orange on a component or an orange label on or near a component indicates that the component can be
hot-swapped, which means that if the server and operating system support hot-swap capability, you can
remove or install the component while the server is running. (Orange can also indicate touch points on
Dual-port
PCI riser network System PCI riser
connector 2 connector battery connector 1
SAS 1
Video graphic adapter
power connector for riser 2 SAS 0
RAID upgrade
USB hypervisor
connector
connector
Microprocessor 2
DIMM connectors
Microprocessor 1
SAS/SATA backplane
configuration connector 1
Fan 4
SAS/SATA backplane
power connector 1
Video graphic adapter Fan 3 Fan 2 SAS/SATA Fan 1 Video and USB
power connector for riser 1 backplane breakout connector
configuration
connector 2
System
Serial Video management Ethernet connector/
USB connectors connector connector (dedicated) System management (shared)
Important:
1. Before you change any switch settings or move any jumpers, turn off the server; then, disconnect all
power cords and external cables. Review the information in “Safety” on page v, “Installation guidelines”
on page 34, “Handling static-sensitive devices” on page 36, and “Turning off the server” on page 23.
2. Any system-board switch or jumper block that is not shown in the illustrations in this document are
reserved.
3. If there is a clear protective sticker on the top of the switch blocks, you must remove and discard it to
access the switches.
CMOS clear
3 2 1 jumper (JP1)
1
System TPM physical 2
presence jumper (JP20) 3
Changing the position of this switch does not affect the administrator
password check if an administrator password is set.
The following table describes the functions of the button on the system board.
System-board LEDs
The following illustration shows the light-emitting diodes (LEDs) on the system board.
Standby power
LED
Dual-port network
adapter LED
System battery
error LED
DIMM 19-24
error LEDs DIMM 1-6
(under the latches) error LEDs
(under the latches)
Microprocessor 2 Microprocessor 1
error LED error LED
Microprocessor 2 Microprocessor 1
DIMMs 7-18
Adapter Adapter
connectors connectors
000000
0000000
000000
0000000
000000
0000000
00000
000000
00000
0000000
00
00000
00000
Adapter Adapter
0000000
00000
00000
00
Full-length
adapter
bracket Full-length
adapter
bracket
Note: Error LEDs remain lit only while the server is connected to power.
000
000
0000000
000
0000000
0000000
0000
0000000
00
0000
0000
00
0000
0000
0000
Installation guidelines
Use this information for installation.
Attention: Static electricity that is released to internal server components when the server is powered-on
might cause the system to halt, which might result in the loss of data. To avoid this potential problem,
always use an electrostatic-discharge wrist strap or other grounding system when removing or installing a
hot-swap device.
Some cluster solutions require specific code levels or coordinated code updates. If the device is part
of a cluster solution, verify that the latest level of code is supported for the cluster solution before you
update the code.
For additional information about tools for updating, managing, and deploying firmware, see the
ToolsCenter for System x and BladeCenter at http://publib.boulder.ibm.com/infocenter/toolsctr/v1r0/.
• Before you install optional hardware, make sure that the server is working correctly. Start the server, and
make sure that the operating system starts, if an operating system is installed, or that a 19990305 error
code is displayed, indicating that an operating system was not found but the server is otherwise working
To help ensure proper system cooling and system reliability, make sure that the following requirements
are met:
• Each of the drive bays has a drive or a filler panel and electromagnetic compatibility (EMC) shield
installed in it.
• Each of the power-supply bays has a power supply or a filler installed in it.
• If the server has redundant power, each of the power-supply bays has a power supply installed in it.
• There is adequate space around the server to allow the server cooling system to work properly. Leave
approximately 50 mm (2.0 in.) of open space around the front and rear of the server. Do not place
objects in front of the fans. For proper cooling and airflow, replace the server cover before you turn on
the server. Operating the server for extended periods of time (more than 30 minutes) with the server
cover removed might damage server components.
• You have followed the cabling instructions that come with optional adapters.
• You have replaced a failed fan within 48 hours.
• You have replaced a hot-swap fan within 30 seconds of removal.
Attention: Static electricity that is released to internal server components when the server is powered-on
might cause the server to halt, which might result in the loss of data. To avoid this potential problem,
always use an electrostatic-discharge wrist strap or other grounding system when you work inside the
server with the power on.
You might have to have the server turned on while the cover is off, to look at light path diagnostics LEDs or
replace hot swap components. Follow these guidelines when you work inside a server that is turned on:
• Avoid wearing loose-fitting clothing on your forearms. Button long-sleeved shirts before working inside
the server; do not wear cuff links while you are working inside the server.
• Do not allow your necktie or scarf to hang inside the server.
• Remove jewelry, such as bracelets, necklaces, rings, and loose-fitting wrist watches.
• Remove items from your shirt pocket, such as pens and pencils, that could fall into the server as you
lean over it.
• Avoid dropping any metallic objects, such as paper clips, hairpins, and screws, into the server.
Attention: Static electricity can damage the server and other electronic devices. To avoid damage, keep
static-sensitive devices in their static-protective packages until you are ready to install them.
To reduce the possibility of damage from electrostatic discharge, observe the following precautions:
• Limit your movement. Movement can cause static electricity to build up around you.
• The use of a grounding system is recommended. For example, wear an electrostatic-discharge wrist
strap, if one is available. Always use an electrostatic-discharge wrist strap or other grounding system
when working inside the server with the power on.
• Handle the device carefully, holding it by its edges or its frame.
• Do not touch solder joints, pins, or exposed circuitry.
• Do not leave the device where others can handle and damage it.
• While the device is still in its static-protective package, touch it to an unpainted metal surface on the
outside of the server for at least 2 seconds. This drains static electricity from the package and from
your body.
• Remove the device from its package and install it directly into the server without setting down the device.
If it is necessary to set down the device, put it back into its static-protective package. Do not place the
device on the server cover or on a metal surface.
• Take additional care when handling devices during cold weather. Heating reduces indoor humidity
and increases static electricity.
Step 1. Read the safety information that begins on page “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Turn off the server and peripheral devices and disconnect the power cords and all external cables,
if necessary.
Step 3. If the server has been installed in a rack, slide the server out from the rack enclosure.
2 Cover-release
latch
0
1 0
000000000000
000000000000
000000000000
000000000000
000000000000
3
0
000000000000
000000000000
Step 4. Pull up firmly on the blue latch on the top (in the center of the front of the server) of the cover and
slide the cover toward the rear of the server until the cover has disengaged from the chassis.
Step 5. Lift the server cover off the server and set it aside.
Attention: For proper cooling and airflow, replace the server cover before you turn on the server.
The server comes with one riser-card assembly (with option to add one more) that each contains two to
three PCI slots. See “Server features and specifications” on page 6 for a list of PCI riser-card assemblies
that you can use with the server.
Step 1. Read the safety information that begins on page “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Turn off the server and peripheral devices, and disconnect the power cord and all external cables.
PCI riser-card
assembly 2
000000
000000
000000
0000
000000
0000
00
0000
00
PCI riser-card
assembly 1
000
000000
000
000000
000000
000
000000
000
0
000
0000
0000
Step 1. Read the safety information that begins on page “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Turn off the server and peripheral devices and disconnect the power cords and all external cables
(see “Turning off the server” on page 23).
Step 3. Remove the cover (see “Removing the cover” on page 37).
Step 4. Remove PCI riser-card assemblies, if necessary (see “Removing a PCI riser-card assembly” on
page 221).
PCI riser-card
assembly 2
000000
000000
000000
0000
000000
0000
00
0000
00
PCI riser-card
assembly 1
000
000000
000
000000
000000
000
000000
000
0
Air baffle
000
0000
0000
Attention: For proper cooling and airflow, replace the air baffle before you turn on the server.
Operating the server with the air baffle removed might damage server components.
Note: It is not necessary to capture adaptor card with the full-length adaptor bracket when installing half
length adaptor cards.
If you are installing a full-length adapter in the upper riser-card PCI slot, you must first stretch the PCI
riser-card assembly.
Step 2. Rotate the thumbscrew, which is close by the PCI slot end, counterclockwise and lengthen the PCI
riser-card assembly.
Step 3. Fasten the thumbscrew.
Step 4. Return to the adapter-installation instructions (see “Replacing an adapter” on page 228).
If you are removing a full-length adapter in the upper riser-card PCI slot and will replace it with a shorter
adapter or no adapter, you must shrink the full-length PCI riser-card assembly.
To shrink the full-length PCI riser-card assembly, complete the following steps:
Step 1. Rotate the thumb screw, which is far from the PCI slot end, counterclockwise and shorten the PCI
riser-card assembly.
Drive IDs
The drive ID that is assigned to each drive is printed on the front or rear of the server. The following
illustrations show the locations of the IDs of the drives. The ID numbers and the drive bay numbers are
the same.
The following illustration shows the location of the IDs of the hard disk drives. The ID numbers and the
drive bay numbers are the same.
Bay 0 Bay 23
Figure 26. Front view: 2.5-inch hot-swap hard disk drive IDs
Bay 24 Bay 25
000
00
000
0000000
000
00
000
000
000
000
0000000
000
000
000
0000000 0000000
00
000
000
000
00
00
000
00
Figure 27. Rear view: 2.5-inch hot-swap hard disk drive IDs
00000 00000
00000 00000
00000 00000
00000 00000
Figure 28. Front view: 2.5-inch and 1.8-inch hot-swap drive IDs
Note: If you have only one hard disk drive, you must install it in the bay 0.
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Remove the filler panel from the empty drive bay. Keep the filler panel in a safe place.
Step 3. Touch the static-protective package that contains the drive to any unpainted metal surface on the
server; then, remove the drive from the package and place it on a static-protective surface.
Step 4. Install a 2.5-inch hot-swap drive:
a. Make sure that the tray handle is in the open (unlocked) position.
b. Align the drive with the guide rails in the bay.
Latch
Handle
c. Gently push the drive into the bay until the drive stops.
d. Rotate the tray handle to the closed (locked) position.
Step 5. Install a 1.8-inch hot-swap drive:
a. Insert the drive into the drive bay with the label side of the drive facing the right side of the
server.
0000
0000
0000
0000
000
000
000
000
Filler
b. Push the drive tray into the drive bay and rotate the drive tray handle to the closed position
and ensure that the latch is in the locked position.
c. Reinstall the filler panel.
Step 6. Check the hard disk drive status LED to verify that the hard disk drive is operating correctly. If
the yellow hard disk drive status LED of a drive is lit continuously, that drive is faulty and must be
replaced. If the green hard disk drive activity LED is flashing, the drive is being accessed.
Note: If the server is configured for RAID operation using a ServeRAID adapter, you might have
to reconfigure your disk arrays after you install hard disk drives. See the ServeRAID adapter
documentation for additional information about RAID operation and complete instructions for
using the ServeRAID adapter.
If you have other devices to install or remove, do so now. Otherwise, go to “Completing the installation”
on page 94.
Note: Values for these voltages are “specified” which means the device characteristics such as
timing are supported at this voltage. Values are “operable” which means that the devices can
be operated safely at this voltage. However, device characteristics such as timing may not
be guaranteed. All devices must be “tolerant” of the highest DDR3 nominal voltage of 1.5 V,
meaning that they may not operate at 1.5 V but may be powered at that voltage without damage
to the devices.
– wwwww is the DIMM bandwidth, in MBps
6400 = 6.40 GBps (DDR3-800 SDRAMs, 8-byte primary data bus)
8500 = 8.53 GBps (DDR3-1066 SDRAMs, 8-byte primary data bus)
10600 = 10.66 GBps (DDR3-1333 SDRAMs, 8-byte primary data bus)
12800 = 12.80 GBps (DDR3-1600 SDRAMs, 8-byte primary data bus)
14900 = 14.93 GBps (DDR3-1866 SDRAMs, 8-byte primary data bus)
– m is the DIMM type
E = Unbuffered DIMM (UDIMM) with ECC (x72-bit module data bus)
L = Load Reduction DIMM (LRDIMM)
R = Registered DIMM (RDIMM)
U = Unbuffered DIMM with no ECC (x64-bit primary data bus)
– aa is the CAS latency, in clocks at maximum operating frequency
– bb is the JEDEC SPD Revision Encoding and Additions level
– cc is the reference design file for the design of the DIMM
– d is the revision number of the reference design of the DIMM
Note: To determine the type of a DIMM, see the label on the DIMM. The information on the label is in
the format xxxxx nRxxx PC3v-xxxxxx-xx-xx-xxx. The numeral in the sixth numerical position indicates
whether the DIMM is single-rank (n=1), dual-rank (n=2), or quad-rank (n=4).
• The following rules apply to DDR3 RDIMM speed as it relates to the number of RDIMMs in a channel:
– When you install 1 RDIMM per channel, the memory runs at 1866 MHz
– When you install 2 RDIMMs per channel, the memory runs at 1600 MHz
– When you install 3 RDIMMs per channel, the memory runs at 1066 MHz
– All channels in a server run at the fastest common frequency
– Do not install registered, unbuffered, and load reduction DIMMs in the same server
• The maximum memory speed is determined by the combination of the microprocessor, DIMM speed,
DIMM type, Operating Modes in UEFI settings, and the number of DIMMs installed in each channel.
• The UDIMM option that is available for the server is 4 GB. The server supports a minimum of 4 GB and a
maximum of 64 GB of system memory using UDIMMs.
• The RDIMM options that are available for the server are 2 GB, 4 GB, 8 GB, and 16 GB. The server
supports a minimum of 2 GB and a maximum of 384 GB of system memory using RDIMMs.
• The LRDIMM option that is available for the server is 32 GB. The server supports a minimum of 32 GB
and a maximum of 768 GB of system memory using LRDIMMs.
Note: The amount of usable memory is reduced depending on the system configuration. A certain
amount of memory must be reserved for system resources. To view the total amount of installed memory
and the amount of configured memory, run the Setup utility. For additional information, see “Configuring
the server” on page 100.
• A minimum of one DIMM must be installed for each microprocessor. For example, you must install a
minimum of two DIMMs if the server has two microprocessors installed. However, to improve system
performance, install a minimum of four DIMMs for each microprocessor.
• DIMMs in the server must be the same type (RDIMM, UDIMM, or LRDIMM) to ensure that the server
will operate correctly.
• When you install one quad-rank DIMM in a channel, install it in the DIMM connector furthest away from
the microprocessor.
1. You can install DIMMs for microprocessor 2 as soon as you install microprocessor 2; you do not have
to wait until all of the DIMM slots for microprocessor 1 are filled.
2. DIMM slots 13-24 are reserved for microprocessor 2; thus, DIMM slots 13-24 are enabled when
microprocessor 2 is installed.
The following illustration shows the location of the DIMM connectors on the system board.
Depending on the server model, the server may come with a minimum of one 2 GB or 4 GB DIMM installed
in slot 1. When you install additional DIMMs, install them in the order shown in the following table to optimize
system performance. In general, all three channels on the memory interface for each microprocessor can be
populated in any order and have no matching requirements.
If a failure occurs, the memory controller switches from the primary pair of memory DIMMs to the backup
pair of DIMMs. To enable memory mirrored channel through the Setup utility, select System Settings ➙
Memory. For more information, see “Using the Setup utility” on page 103. When you use the memory
mirrored channel feature, consider the following information:
The following diagram lists the DIMM connectors on each memory channel.
The following table shows the installation sequence for memory mirrored channel mode:
The maximum available memory is reduced when memory rank sparing mode is enabled.
The following diagram lists the DIMM connectors on each memory channel.
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Turn off the server and peripheral devices and disconnect the power cords and all external cables,
if necessary.
Attention: To avoid breaking the retaining clips or damaging the DIMM connectors, open and
close the clips gently.
Step 7. Touch the static-protective package that contains the DIMM to any unpainted metal surface on the
outside of the server. Then, remove the DIMM from the package.
Step 8. Turn the DIMM so that the alignment slot align correctly with the alignment tab.
Step 9. Insert the DIMM into the connector by aligning the edges of the DIMM with the slots at the ends of
the DIMM connector (see “System-board optional-device connectors” on page 32 for the locations
of the DIMM connectors).
Step 10. Firmly press the DIMM straight down into the connector by applying pressure on both ends of the
DIMM simultaneously. The retaining clips snap into the locked position when the DIMM is firmly
seated in the connector.
Note: If there is a gap between the DIMM and the retaining clips, the DIMM has not been correctly
inserted; open the retaining clips, remove the DIMM, and then reinsert it.
If you have other devices to install or remove, do so now. Otherwise, go to “Completing the installation”
on page 94.
Installing an adapter
Use this information to install an adapter.
• Locate the documentation that comes with the adapter and follow those instructions in addition to
the instructions in this section.
• The server provides two internal SAS connectors and two SAS/SATA RAID riser-card slots on the system
board. See “System-board optional-device connectors” on page 32 for the location of the internal
SAS/SATA RAID connector and riser-card slots. You can replace the Lenovo ServeRAID SAS/SATA
adapter with an optional Lenovo ServeRAID SAS/SATA adapter in the slot. For configuration information,
see the ServeRAID documentation at http://www.lenovo.com/support.
• Do not set the maximum digital video adapter resolution above 1600 x 1200 at 75 Hz for an LCD monitor.
This is the highest resolution that is supported for any add-on video adapter that you install in the server.
• The server does not support legacy 5V PCI adapters.
• When you install any PCI adapter, the power cords must be disconnected from the power source before
you remove the PCI Express riser-card assembly and the PCI-X riser-card assembly. Otherwise, the
active power management event signal will be disabled by the system-board logic, and the Wake on LAN
feature might not work. However, after the server is powered-on locally, the active power manager active
power management event signal will be enabled by the system-board logic.
• The server provides two PCI riser-card slots on the system board. If you want to install a PCI Express or
PCI-X adapter, you must order the PCI riser-card option.
• If you are installing a ServeRAID-M5110 or ServeRAID-M5120 adapter, it can only be installed in PCI
slot 1, 2, 4, or 5.
The following table shows the locations of the adapter expansion slots from the rear of the server.
Table 10. The maximum adapter dimension supported in each slot (rear view)
PCI riser-card assembly 1 PCI riser-card assembly 2
1 Full height, up to full length 4 Full height, up to full length
2 Full height, half length 5 Full height, up to full length
3 Full height, half length 6 Full height, half length
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Turn off the server and peripheral devices and disconnect the power cords and all external cables.
Step 3. Remove the server cover (see “Removing the cover” on page 37).
Step 4. Determine which expansion slot you will use for the adapter.
Step 5. If you are installing an adapter in PCI expansion slot 1, 2, or 3, remove PCI riser-card assembly 1; if
you are installing an adapter in PCI expansion slot 4, 5, or 6, remove PCI riser-card assembly 2.
See “Removing a PCI riser-card assembly” on page 221.
Step 6. Rotate the bracket out of the way.
Step 7. Slide the expansion-slot cover out of the PCI riser-card assembly expansion slot.
Adapter
connectors 00000000
Bracket
00000000
Expansion-slot
00000000
cover
0000
00000000
0000
0000
0000
0000
0000
0000
00
0000
0000
0000
Full-length
adapter Adapter
bracket
a. Riser-card assembly 1: if the adapter is a full-length adapter for the upper expansion slot in
the riser card, remove the full-length-adapter bracket from underneath the top of the riser-card
assembly (if any) and keep it in a safe place for potential future use.
PCI
riser-card
assembly
0000000
0000000
0000000
0000
0000000
0000
0000
00
0000
0000
0000
Full-length
adapter
bracket
b. Riser-card assembly 2: if the adapter is a full-length adapter for the upper expansion slot in
the riser card, the full-length-adapter bracket is on the cage by default.
Step 8. Connect any required cables to the adapter (see “Internal cable routing and connectors” on page
179).
Attention:
• When you route cables, do not block any connectors or the ventilated space around any of
the fans.
• Make sure that cables are not routed on top of components that are under the PCI riser-card
assembly.
If you have other devices to install or remove, do so now. Otherwise, go to “Completing the installation”
on page 94.
You can only install SeveRAID-H1110 adapter in the rear two hard-disk-drive kit.
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Turn off the server and peripheral devices and disconnect the power cords and all external cables.
Step 3. Remove the server cover (see “Removing the cover” on page 37).
Step 4. Remove the rear two hard-disk-drive kit (see “Removing the rear two hard-disk-drive kit” on
page 224).
Step 5. Follow the cabling instructions, if any come with the adapter. Route the adapter cables before
you install the adapter.
Attention:
• When you route cables, do not block any connectors or the ventilated space around any of
the fans.
• Make sure that cables are not routed on top of components under the rear two hard-disk-drive
kit.
• Make sure that cables are not pinched by the server components.
Step 6. Align the adapter with the slot on the rear two hard-disk-drive kit.
Step 7. Press the adapter firmly into the slot on the rear two hard-disk-drive kit.
Bracket
Adapter
00000000
00000000
Expansion-slot
connector 00000000
cover
00000000
0000
0000
0000
0000
Adapter
Step 8. Replace the rear two hard-disk-drive kit in the server (see “Replacing the rear two hard-disk-drive
kit” on page 225).
If you have other devices to install or remove, do so now. Otherwise, go to “Completing the installation”
on page 94.
To install the ServeRAID adapter memory module, complete the following steps:
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Turn off the server and peripheral devices and disconnect all power cords.
Step 3. Remove the cover (see “Removing the cover” on page 37).
Step 4. Connect the cable to the ServeRAID adapter memory module.
Step 5. Align the memory module with the retention pins. Install the memory module into the system board.
Connector
Rentention pins
Step 6. Connect the other end of the cable to the flash power module.
00000
00000
00000
00000
00000
Note: Make sure the flash power module is seated properly (see “Installing a RAID adapter battery
or flash power module” on page 54).
If you have other devices to install or remove, do so now. Otherwise, go to “Completing the installation”
on page 94.
Important:
• The battery must recharge for at least 6 hours under normal operating conditions. To protect your data,
the ServeRAID controller firmware changes the write policy to write-through until the battery unit is
sufficiently charged. When the battery unit is charged, the ServeRAID controller firmware changes the
write policy to write-back.
• For brevity, in this documentation the Intelligent Battery Backup Unit (iBBU) is often referred to as the
battery.
To install a RAID adapter battery or flash power module, complete the following steps:
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Turn off the server and peripheral devices and disconnect all power cords and external devices
(see “Turning off the server” on page 23).
Step 3. Remove the cover (see “Removing the cover” on page 37).
Step 4. Push the tab to open the cover on top of the air baffle.
Step 5. Connect one end of the cable to the ServeRAID memory module.
Step 6. Route the battery or flash power module cable along the chassis.
Attention: Make sure that the cable is not pinched and does not cover any connectors or obstruct
any components on the system board.
Step 7. Install the battery or flash power module on top of the air baffle.
a. Align the battery or flash power module cable connector with the slot on the holder. Place
the battery or flash power module into the holder and make sure that the holder engages
the battery or flash power module securely.
Note: The positioning of the battery or flash power module depends on the type of the
batteries or flash power modules that you install.
b. Connect the other end of the cable to the battery or flash power module.
00000
00000
00000
00000
00000
Note: Make sure the battery or flash power module is seated properly.
If you have other devices to install or remove, do so now. Otherwise, go to “Completing the installation”
on page 94.
To order a dual-port network adapter option, contact your Lenovo sales representative or Lenovo reseller.
The following notes describe the types of adapters that the server supports and other information that
you must consider when you install an adapter:
• To configure network adapters, complete the following steps:
1. From the Setup utility main menu (see “Using the Setup utility” on page 103), select System Settings
➙ Network.
2. From the Network Device List, select one network adapter.
Note: You might need to enter each item (displaying MAC address) to see detailed information.
3. Press Enter to configure the network adapter settings.
Note: You might need to enter each item (displaying MAC address) to see detailed information.
3. Press Enter to configure Emulex network adapter, select Personality and press Enter to change
the settings.
– NIC
– iSCSI (enabled after FoD installed)
– FCoE (enabled after FoD installed)
• To download the latest version of drivers for iSCSI and FCoE from the Lenovo website, complete the
following steps:
1. Go to http://www.ibm.com/support/ fixcentral.
2. Click Product support ➙ System x ➙ Product family ➙ System x3650 M4 HD ➙ 5460.
3. From the Operating system menu, select your operating system, and then click Search to display
the available drivers.
4. Download the latest version of drivers.
– Emulex iSCSI Device Driver for Windows 2008
– Emulex FCoE Device Driver for Windows 2008
Note: Changes are made periodically to the Lenovo website. The actual procedure might vary slightly
from what is described in this document.
• Port 0 on the Emulex Dual Port 10GbE SFP+ Embedded VFA III can be configured as shared system
management.
• When the server is in standby mode, both ports on the Emulex Dual Port 10GbE SFP+ Embedded VFA
III function at 100M connection speed with Wake on LAN feature.
The Emulex Dual Port 10GbE SFP+ Embedded VFA III is automatically disabled if one of the following
errors occurs:
• An error log indicates a temperature warning for the Ethernet adapter.
• All power supplies are removed or the server is disconnected from the power source.
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Turn off the server and peripheral devices and disconnect the power cords and all external cables,
if necessary.
Step 3. Remove the cover (see “Removing the cover” on page 37).
Step 4. Remove PCI riser-card assembly 2, if any (see “Removing a PCI riser-card assembly” on page 221).
Step 5. Loosen the thumbscrew to remove the network adapter filler panel on the rear of the chassis (if
it has not been removed already).
00
00
00
00
00
000
000
000
00
000
000
Step 6. Touch the static-protective package that contains the new adapter to any unpainted metal surface
on the server. Then, remove the adapter from the package.
Step 7. Align the adapter so that the port connectors on the adapter line up with the pin and thumbscrew
on the chassis; then, align the connector of the adapter with the adapter connector on the system
board.
Screw holes
Retention
brackets
00
00
00
00
00
000
000
000
00
000
Thumbscrew
000
Pin
Network
adapter connector
Step 8. Press the adapter firmly until the pin, and retention brackets engage the adapter. Make sure the
adapter is securely seated on the connector on the system board.
Attention: Make sure the port connectors on the adapter are aligned properly with the chassis on
the rear of the server. An incorrectly seated adapter might cause damage to the system board
or the adapter.
Step 9. Fasten the thumbscrew on the rear side of the chassis.
Retention
brackets
00
00
00
00
00
000
000
000
00
000
Thumbscrew
000
Pin
Step 10. Fasten the two captive screws on the network adapter.
Step 11. Reinstall PCI riser-card assembly 2 in PCI riser connector 2 if you have removed it previously (see
“Replacing a PCI riser-card assembly” on page 222).
If you have other devices to install or remove, do so now. Otherwise, go to “Completing the installation”
on page 94.
The following notes describe the type of power supply that the server supports and other information that
you must consider when you install a power supply:
• Before you install an additional power supply or replace a power supply with one of a different wattage,
you may use the Power Configurator utility to determine current system power consumption. For more
information and to download the utility, go to http://www.ibm.com/systems/ bladecenter/resources/
powerconfig.html.
• The server comes with one hot-swap 12-volt output power supply that connects to power supply bay 1.
The input voltage is 100-127 V ac or 200-240 V ac auto-sensing.
• Power supplies in the server must be with the same power rating or wattage to ensure that the server will
operate correctly. For example, you cannot mix 550-watt and 750-watt power supplies in the server.
• Power supply 1 is the default/primary power supply. If power supply 1 fails, you must replace the power
supply with the same wattage immediately.
• You can order an optional power supply for redundancy.
Statement 5
CAUTION:
The power control button on the device and the power switch on the power supply do not turn off
the electrical current supplied to the device. The device also might have more than one power
cord. To remove all electrical current from the device, ensure that all power cords are disconnected
from the power source.
2
1
Statement 8
CAUTION:
Never remove the cover on a power supply or any part that has the following label attached.
Hazardous voltage, current, and energy levels are present inside any component that has this label
attached. There are no serviceable parts inside these components. If you suspect a problem with
one of these parts, contact a service technician.
0000000
0000
0000000
0000000
0000000
0000
0000
0000
0000000
0000
0000
0000
0000000
0000
0000000
0000000
0000
0000
0000
0000
00
0000
Power supply
000
filler panel
000
Hot-swap
power supply 2
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Touch the static-protective package that contains the hot-swap power supply to any unpainted
metal surface on the server; then, remove the power supply from the package and place it on
a static-protective surface.
Step 3. If you are adding a power supply to the server, attach the redundant power information label that
comes with this option on the server cover near the power supplies.
Step 4. Grasp the handle on the rear of the power supply and slide the power supply forward into the
power-supply bay until it clicks. Make sure that the power supply connects firmly into the
power-supply connector.
Step 10. If you are adding a power supply to the server, attach the redundant power information label that
comes with this option on the server cover near the power supplies.
XXXW ~ AC XXXW ~ AC
1 xxx-xxx/ 2 xxx-xxx/
xxx-xxxV~ xxx-xxxV~
x,x/x,x A x,x/x,x A
xx/xx Hz xx/xx Hz
0000
00000
0000
00000
00000
0000
00000
0000
00000
0000
00
00000
000
00
00000
000
000
Power supplies
The following notes describe the type of power supply that the server supports and other information that
you must consider when you install a power supply:
• Before you install an additional power supply or replace a power supply with one of a different wattage,
you may use the Power Configurator utility to determine current system power consumption. For more
information and to download the utility, go to http://www.ibm.com/systems/ bladecenter/resources/
powerconfig.html.
• The server comes with one hot-swap 12-volt output power supply that connects to power supply bay 1.
The input voltage is -48 V dc or -60 V dc auto-sensing.
• Before you install a dc power supply in the server, you must remove all ac power supplies. Do not use
both ac and dc power supplies in the same server. Install up to two dc power supplies or up to two ac
power supplies, but not a combination.
Regulations
• It is the customer's responsibility to supply the necessary power cable.
To reduce the risk of electric shock or energy hazards:
– Use a circuit breaker that is rated at 25 amps.
– Use 2.5 mm2 (12 AWG) at 90°C copper wire.
– Torque the wiring-terminal screws to 0.50 ~ 0.60 newton-meters (4.43 ~ 5.31 inch-pounds).
For more information, see “Statement 34” on page 67.
• If the power source requires ring terminals, you must use a crimping tool to install the ring terminals to
the power cord wires. The ring terminals must be UL approved and must accommodate the wire that is
described in the above-mentioned note .
Statement 29
CAUTION:
This equipment is designed to permit the connection of the earthed conductor of the dc supply
circuit to the earthing conductor at the equipment.
This equipment is designed to permit the connection of the earthed conductor of the dc supply circuit to the
earthing conductor at the equipment. If this connection is made, all of the following conditions must be met:
• This equipment shall be connected directly to the dc supply system earthing electrode conductor or to a
bonding jumper from an earthing terminal bar or bus to which the dc supply system earthing electrode
conductor is connected.
• This equipment shall be located in the same immediate area (such as, adjacent cabinets) as any other
equipment that has a connection between the earthed conductor of the same dc supply circuit and the
earthing conductor, and also the point of earthing of the dc system. The dc system shall not be earthed
elsewhere.
• The dc supply source shall be located within the same premises as this equipment.
• Switching or disconnecting devices shall not be in the earthed circuit conductor between the dc source
and the point of connection of the earthing electrode conductor.
Statement 31
To Connect: To Disconnect:
1. Turn OFF all power sources and equipment that is to 1. Turn OFF all power sources and equipment that is to
be attached to this product. be attached to this product.
2. Attach signal cables to the product. • For ac systems, remove all power cords from the
3. Attach power cords to the product. chassis power receptacles or interrupt power at
the ac power distribution unit.
• For ac systems, use appliance inlets.
• For dc systems, disconnect dc power sources
• For dc systems, ensure correct polarity of -48 V dc at the breaker panel or by turning off the power
connections: RTN is + and -48 V dc is -. Earth source. Then, remove the dc cables.
ground should use a two-hole lug for safety.
2. Remove the signal cables from the connectors.
4. Attach signal cables to other devices.
3. Remove all cables from the devices.
5. Connect power cords to their sources.
6. Turn ON all the power sources.
Statement 33
CAUTION:
This product does not provide a power-control button. Turning off blades or removing power modules
and I/O modules does not turn off electrical current to the product. The product also might have more
than one power cord. To remove all electrical current from the product, make sure that all power
cords are disconnected from the power source.
CAUTION:
To reduce the risk of electric shock or energy hazards:
• This equipment must be installed by trained service personnel in a restricted-access location,
as defined by the NEC and IEC 60950-1, First Edition, The Standard for Safety of Information
Technology Equipment.
• Connect the equipment to a properly grounded safety extra low voltage (SELV) source. A SELV
source is a secondary circuit that is designed so that normal and single fault conditions do not
cause the voltages to exceed a safe level (60 V direct current).
• Incorporate a readily available approved and rated disconnect device in the field wiring.
• See the specifications in the product documentation for the required circuit-breaker rating for
branch circuit overcurrent protection.
• Use copper wire conductors only. See the specifications in the product documentation for the
required wire size.
• See the specifications in the product documentation for the required torque values for the
wiring-terminal screws.
Important: Be sure to read the multilingual safety instructions on the CD that comes with the server
before you use the product.
Attention: Only trained service personnel other than Lenovo service technicians are authorized to install
and remove the -48 volt dc power supply, and make the connections to and disconnections from the -48
volt dc power source. Lenovo service technicians are not certified or authorized to install or remove the
-48 volt power cable. The customer is responsible for ensuring that only trained service personnel install or
remove the -48 volt power cable.
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Touch the static-protective package that contains the hot-swap power supply to any unpainted
metal surface on the server; then, remove the power supply from the package and place it on
a static-protective surface.
Step 3. Turn off the circuit breaker for the dc power source to which the new power supply will be
connected. Disconnect the power cord from the dc power source.
Step 5. If you are installing a hot-swap power supply into an empty bay, remove the power-supply filler
from the power-supply bay.
0000
0000000
0000
0000000
0000000
0000000
0000
0000
0000
0000000
0000
0000
0000
0000000
0000
0000000
0000000
0000
0000
0000
0000
00
0000
Power supply
000
filler panel
000
Hot-swap
power supply 2
Step 6. Grasp the handle on the rear of the power supply and slide the power supply forward into the
power-supply bay until it clicks. Make sure that the power supply connects firmly into the
power-supply connector.
Step 7. Route the power cord through the handle and cable tie if any, so that it does not accidentally
become unplugged.
Step 8. Connect the other ends of the dc power cable to the dc power source. Cut the wires to the
correct length, but do not cut them shorter than 150 mm (6 inch). If the power source requires
ring terminals, you must use a crimping tool to install the ring terminals to the power cord wires.
The ring terminals must be UL approved and must accommodate the wires that are described in
“Regulations” on page 65. The minimum nominal thread diameter of a pillar or stud type of terminal
must be 4 mm; for a screw type of terminal the diameter must be 5.0 mm.
Step 9. Turn on the circuit breaker for the dc power source to which the new power supply is connected.
Step 12. If you are adding a power supply to the server, attach the redundant power information label that
comes with this option on the server cover near the power supplies.
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Turn off the server and peripheral devices and disconnect the power cords.
Step 3. Remove the cover (see “Removing the cover” on page 37).
Step 4. Remove PCI riser-card assembly 2 (see “Removing a PCI riser-card assembly” on page 221).
Step 5. Install the flash device:
USB embedded
hypervisor
flash device
00
00
00
00
00
000
000
000
00
000
000
a. Align the flash device with the connector on the system board and push it into the USB
connector until it is firmly seated.
b. Slightly pull up on the blue lockbar to lock the flash device into the USB connector.
If you have other devices to install or remove, do so now. Otherwise, go to “Completing the installation”
on page 94.
To install the front video and USB breakout cable, complete the following steps:
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Insert the video and USB breakout cable on the breakout connector from the front of the server.
USB port
Video connector
Important: Always use the microprocessor installation tool to install a microprocessor. Failing to use
the microprocessor installation tool may damage the microprocessor sockets on the system board. Any
damage to the microprocessor sockets may require replacing the system board.
• Be extremely careful, the microprocessor socket contacts are very fragile. Do not touch the
microprocessor socket contacts. Contaminants on the microprocessor contacts or microprocessor socket
contacts, such as oil from your skin, can cause connection failures between the contacts and the socket.
• Do not allow the thermal grease on the microprocessor and heat sink to come in contact with anything.
Contact with any surface can contaminate the thermal grease and the microprocessor socket.
• Do not use any tools or sharp objects to lift the locking levers on the microprocessor socket. Doing so
might result in permanent damage to the system board.
• Each microprocessor socket must always contain either a socket cover or a microprocessor and heat sink.
Note: Be sure to use the installation tool that comes with your microprocessor installation tool assembly.
• The server supports up to two multi-core microprocessors. See http://www.lenovo.com/ serverproven/
for a list of supported microprocessors.
• The first microprocessor must always be installed in microprocessor socket 1 on the system board.
• When one microprocessor is installed, the air baffle must be installed to provide proper system cooling.
• Do not remove the first microprocessor from the system board when you install the second
microprocessor.
• When you install the second microprocessor, you must also install additional memory, the fourth and sixth
fans. See “Installing a memory module” on page 43 for details about the installation sequence.
• Do not mix microprocessors with different cores in the same server.
• To ensure proper server operation when you install an additional microprocessor, use microprocessors
that have the same QuickPath Interconnect (QPI) link speed, integrated memory controller frequency, core
frequency, power segment, internal cache size, and type.
• Mixing microprocessors of different stepping levels within the same server model is supported.
• When mixing microprocessors with different stepping levels within the same server model, you do not
have to install the microprocessor with lowest stepping level and features in microprocessor socket 1.
• Both microprocessor voltage regulator modules are integrated on the system board.
• Read the documentation that comes with the microprocessor to determine whether you have to update
the server firmware. To download the latest level of server firmware and other code updates for your
server, go to http://www.ibm.com/support/ fixcentral.
• The microprocessor speeds are automatically set for this server; therefore, you do not have to set any
microprocessor frequency-selection jumpers or switches.
• If the thermal-grease protective cover (for example, a plastic cap or tape liner) is removed from the heat
sink, do not touch the thermal grease on the bottom of the heat sink or set down the heat sink. For more
information about applying or working with thermal grease, see “Thermal grease” on page 79.
Note: Removing the heat sink from the microprocessor destroys the even distribution of the thermal
grease and requires replacing the thermal grease.
• To order an additional optional microprocessor, contact your Lenovo sales representative or Lenovo
reseller.
There are two types of microprocessor installation tools. The tools are similar in function and design,
however Tool A has one setting for installing one size of microprocessor, and supports the following
families of microprocessors: E5-26xx, E5-46xx. Installation Tool B has two settings for installing two
different sizes of microprocessors. The settings that are marked on Tool B are “L” for smaller low core
microprocessors, and “H” for larger high core microprocessors. Installation Tool B supports the following
families of microprocessors: E5-26xx, E5-46xx, E5-26xx v2, E5-46xx v2.
Installation tool
Microprocessor
Cover
Microprocessor
To install an additional microprocessor and heat sink, complete the following steps:
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Turn off the server and peripheral devices and disconnect the power cords and all external cables.
Attention: When you handle static-sensitive devices, take precautions to avoid damage from
static electricity. For details about handling these devices, see “Handling static-sensitive devices”
on page 36.
Step 3. Remove the cover (see “Removing the cover” on page 37).
Step 4. Remove the air baffle (see “Removing the air baffle” on page 38).
Step 5. Rotate the heat sink retention module release lever to the open position.
a. Identify which release lever is labeled as the first release lever to open and open it.
b. Open the second release lever on the microprocessor socket.
c. Open the microprocessor retainer.
Attention: Do not touch the connectors on the microprocessor and the microprocessor socket.
Step 7. Install the microprocessor in the microprocessor socket:
a. Open the packaging that contains the new microprocessor installation tool assembly and
carefully remove the installation tool assembly from the package.
Microprocessor
Cover
c. Align the installation tool with the microprocessor socket. The installation tool rests flush on
the socket only if properly aligned.
d. Install the microprocessor using the following instructions for your installation tool.
• If using Installation Tool A, twist the handle on the microprocessor tool assembly
counterclockwise to the open position to insert the microprocessor into the socket, and
lift the installation tool out of the socket.
• If using Installation Tool B, twist the handle of the installation tool assembly counterclockwise
until the microprocessor is inserted into the socket, and lift the installation tool out of the
socket. The following illustration shows the tool handle in the open position.
L
H
Attention:
• Do not press the microprocessor into the socket.
• Make sure that the microprocessor is oriented and aligned correctly in the socket before
you try to close the microprocessor retainer.
• Do not touch the thermal material on the bottom of the heat sink or on top of the
microprocessor. Touching the thermal material will contaminate it.
Step 8. Remove the microprocessor socket cover, tape, or label from the surface of the microprocessor
socket, if one is present. Store the socket cover in a safe place.
Microprocessor
Attention: When you handle static-sensitive devices, take precautions to avoid damage from
static electricity. For details about handling these devices, see “Handling static-sensitive devices”
on page 36.
Step 9. Close the microprocessor socket release levers and retainer:
Microprocessor
release lever
Microprocessor
Microprocessor
release lever
Attention:
• If you are installing a new heat sink, do not set down the heat sink after you remove the
plastic cover.
• Do not touch the thermal grease on the bottom of the heat sink. Touching the thermal
grease will contaminate it.
Step 10. Install the heat sink.
Attention:
• Do not set down the heat sink after you remove the plastic cover.
a. Remove the plastic protective cover from the bottom of the heat sink.
b. Position the heat sink over the microprocessor. The heat sink is keyed to assist with proper
alignment.
c. Align and place the heat sink on top of the microprocessor in the retention bracket, thermal
material side down.
d. Press firmly on the heat sink.
e. Rotate the heat sink retention module release lever to the closed position and hook it
underneath the lock tab.
If you have other devices to install or remove, do so now. Otherwise, go to “Completing the installation”
on page 94.
When you are installing the heat sink on the same microprocessor that it was removed from, make sure
that the following requirements are met:
• The thermal grease on the heat sink and microprocessor is not contaminated.
• Additional thermal grease is not added to the existing thermal grease on the heat sink and microprocessor.
To replace damaged or contaminated thermal grease on the microprocessor and heat sink, complete the
following steps:
0.02 mL of thermal
grease
Microprocessor
Note: If the grease is properly applied, approximately half of the grease will remain in the syringe.
You can install an Lenovo System x3650 M4 HD Plus Eight 2.5-inch Hot-Swap HDD Assembly Kit
with Expander to add eight additional 2.5-inch hot-swap hard-disk-drive bays in the server. See
http://www.lenovo.com/ serverproven/ for a list of supported optional devices. To order a 8x2.5-inch
hot-swap HDD assembly kit with expander, contact your Lenovo sales representative or Lenovo reseller.
The 8x2.5-inch hot-swap HDD assembly kit with expander contains the following components:
• One expander
• One backplane connection cable
• Two screws
• One power cable
• One configuration cable
• Eight 2.5-inch HDD fillers
To install the 8x2.5-inch hot-swap HDD assembly kit with expander, complete the following steps:
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Remove the cover (see “Removing the cover” on page 37).
Step 3. Touch the static-protective package that contains the expander to any unpainted surface on the
outside of the server; then, grasp the expander and remove it from the package.
Step 4. Install the expander in the farthest slot from the power supplies.
Expander
a. Align the tabs on the bottom of the expander with the slots on the bottom of the backplane
cage.
b. Insert the expander tabs into slots on the bottom of the backplane cage and push the
expander forward into the retention latch (on top of the backplane cage) until the expander is
locked in place.
Step 5. Connect the backplane connection cable, power cable, and the configuration cable.
0000000000
0000000000
0000000000
0000000000
0000000000
0000000000
0000000000
SAS 1
SAS 0
Power cable
Configuration cable
Mini-SAS cable
Power cable
Configuration cable
Expander
Configuration
cable
Configuration
cable Backplane
Mini-SAS cable Backplane
connection Power
cable cable
Backplane
connection
cable
Power
cable
Step 6. Remove the two 4-drive filler panels from the right side.
Filler panel
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
Step 7. Install the hard disk drives, if any (see “Installing a hot-swap drive” on page 42).
Step 8. Install the 2.5-inch HDD fillers into empty drives.
You can install an Lenovo System x3650 M4 HD Plus Eight 2.5-inch Hot-Swap HDD Assembly Kit to
add eight additional 2.5-inch hot-swap hard-disk-drive bays in the server. See http://www.lenovo.com/
serverproven/ for a list of supported optional devices. To order a 8x2.5-inch hot-swap HDD assembly kit,
contact your Lenovo sales representative or Lenovo reseller.
The 8x2.5-inch hot-swap HDD assembly kit contains the following components:
• One hot-swap HDD backplane
• Two mini-SAS cables
• One power cable
• One configuration cable
• Eight 2.5-inch HDD fillers
To install the 8x2.5-inch hot-swap HDD assembly kit, complete the following steps:
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Remove the cover (see “Removing the cover” on page 37).
Step 3. Touch the static-protective package that contains the backplane to any unpainted surface on the
outside of the server; then, grasp the backplane and remove it from the package.
Step 4. Install the backplane in the farthest slot from the power supplies.
Backplane
a. Align the tabs on the bottom of the backplane with the slots on the bottom of the backplane
cage.
b. Insert the backplane tabs into slots on the bottom of the backplane cage and push the
backplane forward into the retention latch (on top of the backplane cage) until the backplane is
locked in place.
Step 5. Connect the mini-SAS cables, power cable, and the configuration cable.
00000000000
000000000
00000000000
000000000
00000000000
000000000
Port 1
SAS 1
Port 0
SAS 0
Power cable
Configuration cable
Mini-SAS cable
Power cable
Configuration cable
Backplane
Configuration
cable
Expander
Configuration
cable
Power
cable
Step 6. Remove the two 4-drive filler panels from the right side.
Filler panel
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
Step 7. Install the hard disk drives, if any (see “Installing a hot-swap drive” on page 42).
Step 8. Install the 2.5-inch HDD fillers into empty drives.
You can install an Lenovo System x3650 M4 HD 3x8 2.5-inch Hot-Swap HDD Assembly Kit to add eight
additional 2.5-inch hot-swap hard-disk-drive bays in the server. See http://www.lenovo.com/ serverproven/
for a list of supported optional devices. To order a 3x8 2.5-inch hot-swap HDD assembly kit, contact
your Lenovo sales representative or Lenovo reseller.
The 3x8 2.5-inch hot-swap HDD assembly kit contains the following components:
• Two hot-swap HDD backplanes
• One power cable
• One configuration cable
• One backplane power Y-cable
• One backplane configuration Y-cable
• Four mini-SAS cables (820 mm)
• Two mini-SAS cables (925 mm)
• Eight 2.5-inch HDD fillers
To install the 3x8 2.5-inch hot-swap HDD assembly kit, complete the following steps:
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Remove the cover (see “Removing the cover” on page 37).
Step 3. Remove the hard disk drives and filler panels from drive bay 8 to 15.
Step 4. Remove the two 4-drive filler panels from the right side.
Step 5. Disconnect all the cables connected from the expander.
Step 6. Remove the expander from the middle slot. Lift the expander out of the server by pulling it toward
the rear of the server and then lifting it up.
Expander
Step 7. Touch the static-protective package that contains the backplane to any unpainted surface on the
outside of the server; then, grasp the backplane and remove it from the package.
Step 8. Install the backplane in the slot you removed the expander earlier.
Retention latchs
Backplanes
a. Align the tabs on the bottom of the backplane with the slots on the bottom of the backplane
cage.
Riser 1
Riser 2
0000000000
0000000000
0000000000
0000000000
0000000000
0000000000
0000000000
0000000000
Port 1
SAS 1
Port 0
SAS 0
Power cable
Configuration cable
Mini-SAS cable
Power cable
Configuration cable
Backplane
Configuration
cable
Backplane
Configuration
cable
Step 11. Install the hard disk drives (see “Installing a hot-swap drive” on page 42).
Step 12. Install the 2.5-inch HDD fillers into empty drives.
If you have other devices to install or remove, do so now. Otherwise, go to “Completing the installation”
on page 94.
To order the 16x1.8-inch SSD assembly kit, contact your Lenovo sales representative or Lenovo reseller.
To install the 16x1.8-inch SSD assembly kit in the server, complete the following steps.
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Turn off the server and peripheral devices and disconnect the power cords and all external cables,
if necessary.
Step 3. Remove the cover (see “Removing the cover” on page 37).
Step 4. Remove the two 4-drive filler panels from the right side.
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
8x1.8-inch
drive backplane 0000
assembly 0000
0000
0000
0000
0000
0000
0000
0000
1.8-inch
filler panel
Riser 2
00000000000
0000000000
00000000000
0000000000
00000000000
0000000000
00000000000
0000000000
Port 1
SAS 1
Port 0
SAS 0
Power cable
Configuration cable
Mini-SAS cable
Power cable
Configuration cable
Mini-SAS cable
1.8-inch backplane assembly
Configuration
cable
Expander
Configuration
Configuration
cable Power cable
cable
Configuration
Backplane
cable Power
cable
Power
cable
Step 7. Insert the hard disk drives and the filler panels into the bays.
Step 8. Install the cover (see “Replacing the cover” on page 196).
If you have other devices to install or remove, do so now. Otherwise, go to “Completing the installation”
on page 94.
Step 1. If you removed the air baffle, reinstall it (see “Replacing the air baffle” on page 94).
Step 2. If you removed the server cover, replace it (see “Replacing the cover” on page 96).
Step 3. Install the server in the rack cabinet (see the Rack Installation Instructions that come with the
server for instructions).
Step 4. Reconnect the cables and power cords (see “Connecting the external cables” on page 97).
Step 5. Update the server configuration (see “Updating the server configuration” on page 98).
Step 6. Slide the server back into the rack, if necessary.
Step 7. Start the server. Confirm that it starts correctly and recognizes the newly installed devices, and
make sure that no error LEDs are lit.
Step 8. (Business Partners only) Complete the additional steps in “Instructions for Business Partners”
on page 25.
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Turn off the server and peripheral devices and disconnect the power cords and all external cables
(see “Turning off the server” on page 23).
Step 3. Make sure that PCI riser-card assemblies are removed if they are in long position and sitting on the
air baffle (see “Removing a PCI riser-card assembly” on page 221).
Step 4. Align the air baffle pins with the baffle pin holes on both sides of the chassis; then, lower the air
baffle into the server. Press the air baffle down until it is securely seated.
Note: Close the retaining clip on each end of the DIMM connector before installing the air baffle for
proper cooling.
PCI riser-card
assembly 2
000000
000000
000000
0000
000000
0000
00
0000
00
PCI riser-card
assembly 1
000
000000
000
000000
000000
000
000000
000
0
Air baffle
000
0000
0000
PCI riser-card
assembly 2
000000
000000
000000
0000
000000
0000
00
0000
00
PCI riser-card
assembly 1
000
000000
000
000000
000000
000
000000
000
0
000
0000
0000
• PCI riser-card assembly 1: Carefully fit the two alignment slots on the side of the assembly
onto the two alignment brackets in the side of the chassis.
• PCI riser-card assembly 2: Carefully align the bottom edge (the contact edge) of the PCI
riser-card assembly with the PCI riser connector on the system board.
Step 5. Press down on the assembly. Make sure that the PCI riser-card assembly is fully seated in the PCI
riser connector on the system board.
Before you slide the cover forward, make sure that all the tabs on the front, rear, and side of the
cover engage the chassis correctly. If all the tabs do not engage the chassis correctly, it will be
very difficult to remove the cover later.
Step 2. Position the cover on top of the server.
Step 3. Slide the cover toward the front of the server.
Step 4. Make sure that the cover correctly engages all the inset tabs on the server.
Step 5. Press down the blue latch on the top (in the center of the front of the server) of the cover.
2 Cover-release
latch
0
000000000000
000000000000
000000000000
000000000000
1
0
000000000000
000000000000
000000000000
Step 6. Slide the server all the way into the rack until it latches.
The following illustrations show the locations of the input and output connectors on the front and rear of
the server.
000
00
000
0000000
000
00
000
000
000
000
0000000
000
000
000
0000000 0000000
00
000
000
000
00
00
000
00
You must turn off the server before you connect or disconnect cables.
See the documentation that comes with any external devices for additional cabling instructions. It might be
easier for you to route cables before you connect the devices to the server.
If the server comes with an installed operating system, see the documentation that comes with the operating
system for additional cabling instructions.
Some optional devices have device drivers that you must install. For information about installing device
drivers, see the documentation that comes with each device.
If the server has an optional RAID adapter and you have installed or removed a hard disk drive, see the
documentation that comes with the RAID adapter for information about reconfiguring the disk arrays.
For information about configuring the integrated Gigabit Ethernet controller, see “Configuring the Ethernet
controller” on page 114.
Important:
1. Some cluster solutions require specific code levels or coordinated code updates. If the device is part
of a cluster solution, verify that the latest level of code is supported for the cluster solution before
you update the code.
2. Before you update the firmware, be sure to back up any data that is stored in the Trusted Platform
Module (TPM), in case any of the TPM characteristics are changed by the new firmware. For instructions,
see your encryption software documentation.
3. Installing the wrong firmware or device-driver update might cause the server to malfunction. Before you
install a firmware or device-driver update, read any readme and change history files that are provided
with the downloaded update. These files contain important information about the update and the
procedure for installing the update, including any special procedure for updating from an early firmware
or device-driver version to the latest version.
You can install code updates that are packaged as an UpdateXpress System Pack or UpdateXpress CD
image. An UpdateXpress System Pack contains an integration-tested bundle of online firmware and
device-driver updates for your server. Use UpdateXpress System Pack Installer to acquire and apply
UpdateXpress System Packs and individual firmware and device-driver updates. For additional information
and to download the UpdateXpress System Pack Installer, go to the ToolsCenter for System x and
BladeCenter at https://support.lenovo.com/us/en/ documents/LNVO-CENTER and click UpdateXpress
System Pack Installer.
When you click an update, an information page is displayed, including a list of the problems that the update
fixes. Review this list for your specific problem; however, even if your problem is not listed, installing the
update might solve the problem.
Be sure to separately install any listed critical updates that have release dates that are later than the release
date of the UpdateXpress System Pack or UpdateXpress image.
The firmware for the server is periodically updated and is available for download on the Lenovo website. To
check for the latest level of firmware, such as the UEFI firmware, device drivers, and integrated management
module (IMM) firmware, go to http://www.ibm.com/support/ fixcentral.
Download the latest firmware for the server; then, install the firmware, using the instructions that are included
with the downloaded files.
When you replace a device in the server, you might have to update the firmware that is stored in memory on
the device or restore the pre-existing firmware from a CD or DVD image.
• Setup utility
The Setup utility is part of the UEFI firmware. Use it to perform configuration tasks such as changing
interrupt request (IRQ) settings, changing the startup-device sequence, setting the date and time, and
setting passwords. For information about using this program, see “Using the Setup utility” on page 103.
• Boot Manager program
The Boot Manager is part of the UEFI firmware. Use it to override the startup sequence that is set in the
Setup utility and temporarily assign a device to be first in the startup sequence. For more information
about using this program, see “Using the Boot Manager” on page 109.
• LenovoServerGuide Setup and Installation CD
The ServerGuide program provides software-setup tools and installation tools that are designed for the
server. Use this CD during the installation of the server to configure basic hardware features, such as an
integrated SAS/SATA controller with RAID capabilities, and to simplify the installation of your operating
system. For information about using this CD, see “Using the ServerGuide Setup and Installation CD” on
page 102.
• FastSetup
FastSetup is a no-cost software tool that helps simplify the maintenance and deployment of
selected Lenovo BladeCenter chassis, servers, and components. The intuitive graphical interface
initializes all phases of server setup, including discovery, update, and configuration. Features
include templates that enable replication of settings to many servers and automation that
reduces hands-on time and user errors. Wizards and other default settings enable customization
capabilities. The low-touch, set-once and walk-away feature reduces the hands-on server setup
time from days to minutes, particularly for larger deployments. For information about this tool, see
http://www.ibm.com/support/entry/portal/docdisplay?lndocid=TOOL-FASTSET.
• Integrated management module
Use the integrated management module II (IMM2) for configuration, to update the firmware and
sensor data record/field replaceable unit (SDR/FRU) data, and to remotely manage a network. For
information about using the IMM, see “Using the integrated management module” on page 110 and
the Integrated Management Module II User's Guide at http://publib.boulder.ibm.com/infocenter/
systemx/documentation/topic/ com.lenovo.sysx.imm2.doc/ printable_doc.html.
• VMware ESXi embedded hypervisor
An optional USB flash device with VMware ESXi embedded hypervisor software is available for purchase.
Hypervisor is virtualization software that enables multiple operating systems to run on a host system at
the same time. The USB embedded hypervisor flash device can be installed in USB connectors 3 and
4 on the system board. For more information about using the embedded hypervisor, see “Using the
embedded hypervisor” on page 113.
• Remote presence capability and blue-screen capture
The remote presence and blue-screen capture features are integrated functions of the integrated
management module (IMM2). The remote presence feature provides the following functions:
– Remotely viewing video with graphics resolutions up to 1600 x 1200 at 75 Hz, regardless of the system
state
– Remotely accessing the server, using the keyboard and mouse from a remote client
Table 12. Server configuration and applications for configuring and managing RAID arrays
RAID array configuration (before RAID array management (after
Server configuration operating system is installed) operating system is installed)
ServeRAID-H1110 adapter LSI Utility (Setup utility, press MegaRAID Storage Manager (MSM),
Ctrl+C), ServerGuide, Human SAS2IRCU (Command Line) Utility
Interface Infrastructure (HII) for Storage Management
ServeRAID-M1115 adapter MegaRAID BIOS Configuration Utility MegaRAID Storage Manager (MSM),
(press Ctrl+H to start), pre-boot CLI MegaCLI (Command Line Interface),
(press Ctrl+P to start), ServerGuide, and Lenovo Director
HII
ServeRAID-M5110 adapter MegaRAID BIOS Configuration Utility MegaRAID Storage Manager (MSM),
(press Ctrl+H to start), pre-boot CLI MegaCLI, and Lenovo Director
(press Ctrl+P to start), ServerGuide,
HII
ServeRAID-M5120 adapter MegaRAID BIOS Configuration Utility MegaRAID Storage Manager (MSM),
(press Ctrl+H to start), pre-boot CLI MegaCLI, and Lenovo Director
(press Ctrl+P to start), ServerGuide,
HII
1. For more information about the Human Interface Infrastructure (HII) and SAS2IRCU, go to
http://www.ibm.com/support/entry/portal/docdisplay?lndocid=MIGR-5088601.
The ServerGuide Setup and Installation CD provides software setup tools and installation tools that are
designed for your server. The ServerGuide program detects the server model and optional hardware devices
that are installed and uses that information during setup to configure the hardware. The ServerGuide
simplifies the operating-system installations by providing updated device drivers and, in some cases,
installing them automatically.
You can download a free image of the ServerGuide Setup and Installation CD from
http://www.ibm.com/support/entry/portal/ docdisplay?lndocid=SERV-GUIDE.
In addition to the ServerGuide Setup and Installation CD, you must have your operating-system CD to
install the operating system.
ServerGuide features
This information provides an overview of the ServerGuide features.
Features and functions can vary slightly with different versions of the ServerGuide program. To learn more
about the version that you have, start the ServerGuide Setup and Installation CD and view the online
overview. Not all features are supported on all server models.
When you use the ServerGuide Setup and Installation CD, you do not need setup diskettes. You can use the
CD to configure any supported Lenovo server model. The setup program provides a list of tasks that are
required to set up your server model. On a server with a ServeRAID adapter or SAS/SATA controller with
RAID capabilities, you can run the SAS/SATA RAID configuration program to create logical drives.
Note: Features and functions can vary slightly with different versions of the ServerGuide program.
Note: Features and functions can vary slightly with different versions of the ServerGuide program.
1. After you have completed the setup process, the operating-system installation program starts. (You
will need your operating-system CD to complete the installation.)
2. The ServerGuide program stores information about the server model, service processor, hard disk drive
controllers, and network adapters. Then, the program checks the CD for newer device drivers. This
information is stored and then passed to the operating-system installation program.
3. The ServerGuide program presents operating-system partition options that are based on your
operating-system selection and the installed hard disk drives.
4. The ServerGuide program prompts you to insert your operating-system CD and restart the server. At
this point, the installation program for the operating system takes control to complete the installation.
If you have already configured the server hardware and you are not using the ServerGuide program to
install your operating system, you can download operating-system installation instructions for the server
from http://www.lenovo.com/support.
Use the Unified Extensible Firmware Interface (UEFI) Setup Utility program to perform the following tasks:
• View configuration information
• View and change assignments for devices and I/O ports
• Set the date and time
• Set and change passwords
• Set the startup characteristics of the server and the order of startup devices
• Set and change settings for advanced hardware features
• View, set, and change settings for power-management features
• View and clear error logs
• Change interrupt request (IRQ) settings
• Resolve configuration conflicts
Note: Approximately 5 to 10 seconds after the server is connected to power, the power-control
button becomes active.
The following choices are on the Setup utility main menu for the UEFI. Depending on the version of the
firmware, some menu choices might differ slightly from these descriptions.
• System Information
Select this choice to view information about the server. When you make changes through other choices
in the Setup utility, some of those changes are reflected in the system information; you cannot change
settings directly in the system information. This choice is on the full Setup utility menu only.
– System Summary
Select this choice to view configuration information, including the ID, speed, and cache size of the
microprocessors, machine type and model of the server, the serial number, the system UUID, and the
amount of installed memory. When you make configuration changes through other options in the
Setup utility, the changes are reflected in the system summary; you cannot change settings directly in
the system summary.
– Product Data
Select this choice to view the system-board identifier, the revision level or issue date of the firmware,
the integrated management module and diagnostics code, and the version and date.
This choice is on the full Setup utility menu only.
• System Settings
Select this choice to view or change the server component settings.
– Adapters and UEFI Drivers
Select this choice to view information about the UEFI 1.10 and UEFI 2.0 compliant adapters and
drivers installed in the server.
– Processors
Select this choice to view or change the processor settings.
– Memory
Select this choice to view or change the memory settings.
– Devices and I/O Ports
Select this choice to view or change assignments for devices and input/output (I/O) ports. You can
configure the serial ports, configure remote console redirection, enable or disable integrated Ethernet
controllers, the SAS/SATA controllers, SATA optical drive channels, PCI slots, and video controller. If
you disable a device, it cannot be configured, and the operating system will not be able to detect it
(this is equivalent to disconnecting the device).
– Power
Select this choice to view or change power capping to control consumption, processors, and
performance states.
– Operating Modes
Select this choice to view or change the operating profile (performance and power utilization).
– Legacy Support
Select this choice to view or set legacy support.
Passwords
From the User Security menu choice, you can set, change, and delete a power-on password and an
administrator password.
The User Security choice is on the full Setup utility menu only.
If you set only a power-on password, you must type the power-on password to complete the system startup
and to have access to the full Setup utility menu.
If you set a power-on password for a user and an administrator password for a system administrator, you can
type either password to complete the system startup. A system administrator who types the administrator
password has access to the full Setup utility menu; the system administrator can give the user authority to
set, change, and delete the power-on password. A user who types the power-on password has access
to only the limited Setup utility menu; the user can set, change, and delete the power-on password, if the
system administrator has given the user that authority.
Power-on password:
If a power-on password is set, when you turn on the server, you must type the power-on password to
complete the system startup. You can use any combination of 6 - 20 printable ASCII characters for the
password.
When a power-on password is set, you can enable the Unattended Start mode, in which the keyboard and
mouse remain locked but the operating system can start. You can unlock the keyboard and mouse by
typing the power-on password.
If you forget the power-on password, you can regain access to the server in any of the following ways:
• If an administrator password is set, type the administrator password at the password prompt. Start the
Setup utility and reset the power-on password.
• Remove the battery from the server, wait 30 seconds, and then reinstall it.
• Change the position of the power-on password switch (switch 4) on the system board switch block (SW3)
to bypass the power-on password check (see Table 4 “System board SW3 switch block definition” on
page 31 for more information).
CMOS clear
3 2 1 jumper (JP1)
1
System TPM physical 2
presence jumper (JP20) 3
Attention: Before you change any switch settings or move any jumpers, turn off the server; then,
disconnect all power cords and external cables. See the safety information that begins “Safety” on page
v. Do not change settings or move jumpers on any system-board switch or jumper blocks that are
not shown in this document.
While the server is turned off, move power-on password switch (switch 4) on the system board switch
block (SW3) to the On position to enable the power-on password override. You can then start the Setup
utility and reset the power-on password. You do not have to return the switch to the previous position.
The power-on password override switch does not affect the administrator password.
Administrator password:
If an administrator password is set, you must type the administrator password for access to the full Setup
utility menu. You can use any combination of 6 to 20 printable ASCII characters for the password.
Attention: If you set an administrator password and then forget it, there is no way to change, override,
or remove it. You must replace the system board.
The next time the server starts, it returns to the startup sequence that is set in the Setup utility.
To force the server to start from the backup copy, turn off the server; then, place the UEFI boot backup
jumper (JP7) in the backup position (pins 2 and 3). See “System-board switches, jumpers, and buttons”
on page 29 for the location of the UEFI boot backup jumper (JP7).
Use the backup copy of the server firmware until the primary copy is restored. After the primary copy is
restored, turn off the server; then, move the UEFI boot backup jumper (JP7) back to the primary position
(pins 1 and 2).
For additional information and to download the UpdateXpress System Pack Installer, go to the ToolsCenter
for System x and BladeCenter at http://publib.boulder.ibm.com/infocenter/toolsctr/v1r0/ and click
UpdateXpress System Pack Installer.
The IMM also provides the following remote server management capabilities through the ipmitool
management utility program:
• Command-line interface (IPMI Shell)
The command-line interface provides direct access to server management functions through the IPMI
2.0 protocol. Use the command-line interface to issue commands to control the server power, view
system information, and identify the server. You can also save one or more commands as a text file and
run the file as a script.
• Serial over LAN
Establish a Serial over LAN (SOL) connection to manage servers from a remote location. You can remotely
view and change the UEFI settings, restart the server, identify the server, and perform other management
functions. Any standard Telnet client application can access the SOL connection.
For more information about IMM, see the Integrated Management Module II User's Guide at
http://publib.boulder.ibm.com/infocenter/ systemx/documentation/topic/ com.lenovo.sysx.imm2.doc/
printable_doc.html.
The blue-screen capture feature captures the video display contents before the IMM restarts the server when
the IMM detects an operating-system hang condition. A system administrator can use the blue-screen
capture to assist in determining the cause of the hang condition.
If you are logging on to the IMM for the first time after installation, the IMM defaults to DHCP. If a DHCP
server is not available, the IMM uses a static IP address of 192.168.70.125. The default IPv4 host name
is “IMM-” (plus the last 12 characters on the IMM MAC address). The default host name also comes on
the IMM network access tag that comes attached to the power supply on the rear of the server. The IMM
network access tag provides the default host name of the IMM and does not require you to start the server.
The IPv6 link-local address (LLA) is derived from the IMM default host name. The IMM LLA is on the IMM
network access tag is on the power supply on the rear of the server. To derive the link-local address,
complete the following steps:
Step 1. Take the last 12 characters on the IMM MAC address (for example, 5CF3FC5EAAD0).
Step 2. Separate the number into pairs of hexadecimal characters (for example, 5C:F3:FC:5E:AA:D0).
Step 3. Separate the first six and last six hexadecimal characters.
Step 4. Add “FF” and “FE” in the middle of the 12 characters (for example, 5C F3 FC FF FE 5E AA D0).
Step 5. Convert the first pair of hexadecimal characters to binary (for example, 5=0101, C=1100, which
results in 01011100 F3 FC FF FE 5E AA D0).
Step 6. Flip the 7th binary character from left (0 to 1 or 1 to 0), which results in 01011110 F3 FF FE 5E AA D0.
Step 7. Convert the binary back to hexadecimal (for example, 5E F3FCFFFE5EAAD0).
The server comes with a default IP address for the IMM of 192.168.70.125.
Note: Approximately 5 to 10 seconds after the server is connected to power, the power-control
button becomes active.
Step 2. When the prompt <F1> Setup is displayed, press F1. (This prompt is displayed on the screen for
only a few seconds. You must press F1 quickly.) If you have set both a power-on password and
an administrator password, you must type the administrator password to access the full Setup
utility menu.
Step 3. From the Setup utility main menu, select System Settings.
Step 1. On a system that is connected to the server, open a web browser. In the Address or URL field,
type the IP address or host name of the IMM to which you want to connect.
Note: If you are logging on to the IMM for the first time after installation, the IMM defaults to
DHCP. If a DHCP host is not available, the IMM assigns a static IP address of 192.168.70.125.
The IMM network access tag provides the default host name of the IMM and does not require
you to start the server.
Step 2. On the Login page, type the user name and password. If you are using the IMM for the first time,
you can obtain the user name and password from your system administrator. All login attempts are
documented in the system-event log.
Note: The IMM is set initially with a user name of USERID and password of PASSW0RD (with a
zero, not a the letter O). You have read/write access. You must change the default password the
first time you log on.
Step 3. Click Log in to start the session. The System Status and Health page provides a quick view
of the system status.
Note: If you boot to the operating system while in the IMM GUI and the message Booting OS or in
unsupported OS is displayed under System Status ➙ System State, disable Windows 2008 or 2012 firewall
or type the following command in the Windows 2008 or 2012 console. This might also affect blue-screen
capture features.
netsh firewall set icmpsetting type=8 mode=ENABLE
By default, the icmp packet is blocked by Windows firewall. The IMM GUI will then change to “OS booted”
status after you change the setting as indicated above in both the Web and CLI interfaces.
The USB flash device can be installed in USB connectors on the system board (see “System-board internal
connectors” on page 28 for the location of the connectors). Hypervisor is virtualization software that enables
multiple operating systems to run on a host system at the same time. The USB flash device is required to
activate the hypervisor functions.
To start using the embedded hypervisor functions, you must add the USB flash device to the startup
sequence in the Setup utility.
To add the USB flash device to the startup sequence, complete the following steps:
If the embedded hypervisor flash device image becomes corrupt, you can download the image from
http://www-03.ibm.com/systems/x/os/vmware/esxi/.
For additional information and instructions, see VMware vSphere 4.1 Documentation at
http://www.vmware.com/support/pubs/vs_pages/vsp_pubs_esxi41_e_vc41.html or the VMware vSphere
Installation and Setup Guide at http://pubs.vmware.com/vsphere-50/topic/ com.vmware.ICbase/PDF/
vsphere-esxi-vcenter-server-50-installation-setup-guide.pdf.
If the Ethernet ports in the server support auto-negotiation, the controllers detect the data-transfer rate
(10BASE-T, 100BASE-TX, or 1000BASE-T) and duplex mode (full-duplex or half-duplex) of the network
and automatically operate at that rate and mode.
You do not have to set any jumpers or configure the controllers. However, you must install a device driver to
enable the operating system to address the controllers.
To find device drivers and information about configuring the Ethernet controllers, go to
http://www.lenovo.com/support.
For more information and instructions for activating the Features on Demand Ethernet software key, see the
Lenovo Features on Demand User’s Guide. To download the document, go to https://fod.lenovo.com/lkms,
log in, and click Help.
For more information and instructions for activating the Features on Demand RAID software key, see the
Lenovo Features on Demand User’s Guide. To download the document, go to https://fod.lenovo.com/lkms,
log in, and click Help.
The specific procedure for configuring arrays depends on the RAID controller that you are using. For details,
see the documentation for your RAID controller. To access the utility for your RAID controller, complete the
following steps:
Note: Approximately 10 seconds after the server is connected to power, the power-control button
becomes active.
Step 2. When prompted, <F1 Setup> is displayed, press F1. If you have set an administrator password, you
must type the administrator password to access the full Setup utility menu. If you do not type the
administrator password, a limited Setup utility menu is available.
Step 3. Select System Settings ➙ Storage.
Step 4. Press Enter to refresh the list of device drivers.
Step 5. Select the device driver for your RAID controller and press Enter.
Step 6. Follow the instructions in the documentation for your RAID controller.
Lenovo XClarity Administrator offers a free, 90-day trial license that enables you to use all available features
for a limited time. To continue using Lenovo XClarity Administrator after the 90–day trial period, you are
required to purchase a full-function-enablement license for each Lenovo XClarity Administrator instance. You
can purchase and download the license from:
https://support.lenovo.com/us/en/documents/lnvo-lxcaupd
Use the ASU program online or out of band to modify UEFI settings from the command line without the need
to restart the system to access the Setup utility.
You can also use the ASU program to configure the optional remote presence features or other IMM2
settings. The remote presence features provide enhanced systems-management capabilities.
Use the command-line interface to issue setup commands. You can save any of the settings as a file and run
the file as a script. The ASU program supports scripting environments through a batch-processing mode.
If you plan to use Systems Director to manage the server, you must check for the latest applicable Systems
Director updates and interim fixes.
Note: Changes are made periodically to the website. The actual procedure might vary slightly from what is
described in this document.
Step 1. Make sure that you have run the Discovery and Inventory collection tasks.
Step 2. On the Welcome page of the Systems Director web interface, click View updates.
Step 3. Click Check for updates. The available updates are displayed in a table.
Step 4. Select the updates that you want to install, and click Install to start the installation wizard.
Installing updates with your management server is not connected to the Internet
If your management server is not connected to the Internet, to locate and install updates and interim fixes,
complete the following steps:
Step 1. Make sure that you have run the Discovery and Inventory collection tasks.
Step 2. On a system that is connected to the Internet, go to http://www.ibm.com/support/ fixcentral.
Step 3. From the Product family list, select Systems Director.
Step 4. From the Product list, select Systems Director.
Step 5. From the Installed version list, select the latest version, and clickContinue.
Step 6. Download the available updates.
Step 7. Copy the downloaded files to the management server.
Step 8. On the management server, on the Welcome page of the Systems Director web interface, click
the Manage tab, and click Update Manager.
The ASU is an online tool that supports several operating systems. Make sure that you download the version
for your operating system. You can download the ASU from the Lenovo website. To download the ASU and
update the UUID, complete the following steps.
Note: Changes are made periodically to the Lenovo website. The actual procedure might vary slightly
from what is described in this document.
Where:
<uuid_value>
Up to 16-byte hexadecimal value assigned by you.
[access_method]
The access method that you selected to use from the following methods:
imm_internal_ip
The IMM internal LAN/USB IP address. The default value is 169.254.95.118.
Note: If you do not specify any of these parameters, ASU will use the default values. When the
default values are used and ASU is unable to access the IMM using the online authenticated
LAN access method, ASU will automatically use the unauthenticated KCS access method.
The following commands are examples of using the userid and password default values and
not using the default values:
Example that does not use the userid and password default values:
asu set SYSTEM_PROD_DATA.SYsInfoUUID <uuid_value> –user <user_id>
–password <password>
Example that does use the userid and password default values:
asu set SYSTEM_PROD_DATA.SysInfoUUID <uuid_value>
• Online KCS access (unauthenticated and user restricted):
You do not need to specify a value for access_method when you use this access method.
Example:
asu set SYSTEM_PROD_DATA.SysInfoUUID <uuid_value>
The KCS access method uses the IPMI/KCS interface. This method requires that the IPMI
driver be installed. Some operating systems have the IPMI driver installed by default.
ASU provides the corresponding mapping layer. See the Advanced Settings Utility User's
Guide for more details. You can download the Advanced Settings Utility User's Guide at
https://support.lenovo.com/us/en/ documents/LNVO-ASU.
• Remote LAN access, type the command:
Note: When using the remote LAN access method to access IMM using the LAN from a client,
the host and the imm_external_ip address are required parameters.
host <imm_external_ip> [user <imm_user_id>][password <imm_password>]
Where:
imm_external_ip
The external IMM LAN IP address. There is no default value. This parameter is required.
imm_user_id
The IMM account (1 of 12 accounts). The default value is USERID.
imm_password
The IMM account password (1 of 12 accounts). The default value is PASSW0RD (with
a zero 0 not an O).
The following commands are examples of using the userid and password default values and
not using the default values.
Example that does not use the userid and password default values:
asu set SYSTEM_PROD_DATA.SYsInfoUUID <uuid_value> –host <imm_ip>
–user <user_id> –password <password>
Example that does use the userid and password default values:
asu set SYSTEM_PROD_DATA.SysInfoUUID <uuid_value> –host <imm_ip>
• Bootable media:
The ASU is an online tool that supports several operating systems. Make sure that you download the version
for your operating system. You can download the ASU from the Lenovo website. To download the ASU
and update the DMI, complete the following steps.
Note: Changes are made periodically to the Lenovo website. The actual procedure might vary slightly
from what is described in this document.
Where:
<m/t_model>
The server machine type and model number. Type mtm xxxxyyy, where xxxx is the machine
type and yyy is the server model number.
<s/n>
The serial number on the server. Type sn zzzzzzz, where zzzzzzz is the serial number.
<asset_method>
The server asset tag number. Type asset aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa, where
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa is the asset tag number.
[access_method]
imm_internal_ip
The IMM internal LAN/USB IP address. The default value is 169.254.95.118.
imm_user_id
The IMM account (1 of 12 accounts). The default value is USERID.
imm_password
The IMM account password (1 of 12 accounts). The default value is PASSW0RD (with
a zero 0 not an O).
Note: If you do not specify any of these parameters, ASU will use the default values. When the
default values are used and ASU is unable to access the IMM using the online authenticated
LAN access method, ASU will automatically use the unauthenticated KCS access method.
The following commands are examples of using the userid and password default values and
not using the default values.
Examples that do not use the userid and password default values:
asu set SYSTEM_PROD_DATA.SysInfoProdName <m/t_model>
–user <imm_user_id> –password <imm_password>
asu set SYSTEM_PROD_DATA.SysInfoSerialNum <s/n> –user <imm_user_id>
–password <imm_password>
asu set SYSTEM_PROD_DATA.SysEncloseAssetTag <asset_tag>
–user <imm_user_id> –password <imm_password>
Examples that do use the userid and password default values:
asu set SYSTEM_PROD_DATA.SysInfoProdName <m/t_model>
asu set SYSTEM_PROD_DATA.SysInfoSerialNum <s/n>
asu set SYSTEM_PROD_DATA.SysEncloseAssetTag <asset_tag>
• Online KCS access (unauthenticated and user restricted): You do not need to specify a value for
access_method when you use this access method.
The KCS access method uses the IPMI/KCS interface. This method requires that the IPMI driver
be installed. Some operating systems have the IPMI driver installed by default. ASU provides
the corresponding mapping layer. You can download the Advanced Settings Utility User's Guide
at https://support.lenovo.com/us/en/ documents/LNVO-ASU.
• The following commands are examples of using the userid and password default values and
not using the default values.
Examples that do not use the userid and password default values:
asu set SYSTEM_PROD_DATA.SysInfoProdName <m/t_model>
asu set SYSTEM_PROD_DATA.SysInfoSerialNum <s/n>
asu set SYSTEM_PROD_DATA.SysEncloseAssetTag <asset_tag>
• Remote LAN access, type the command:
Note: When using the remote LAN access method to access IMM using the LAN from a client,
the host and the imm_external_ip address are required parameters.
host <imm_external_ip> [user <imm_user_id>][password <imm_password>]
Where:
imm_external_ip
The external IMM LAN IP address. There is no default value. This parameter is required.
If you cannot diagnose and correct a problem by using the information in this chapter, see Appendix D
“Getting help and technical assistance” on page 1135 for more information.
Start here
You can solve many problems without outside assistance by following the troubleshooting procedures in
this documentation and on the World Wide Web.
This document describes the diagnostic tests that you can perform, troubleshooting procedures, and
explanations of error messages and error codes. The documentation that comes with your operating system
and software also contains troubleshooting information.
Diagnosing a problem
Before you contact IBM or an approved warranty service provider, follow these procedures in the order in
which they are presented to diagnose a problem with your server.
Step 1. Return the server to the condition it was in before the problem occurred.
If any hardware, software, or firmware was changed before the problem occurred, if possible,
reverse those changes. This might include any of the following items:
• Hardware components
• Device drivers and firmware
• System software
• UEFI firmware
• System input power or network connections
Step 2. View the light path diagnostics LEDs and event logs.
The server is designed for ease of diagnosis of hardware and software problems.
• Light path diagnostics LEDs: See “Light path diagnostics” on page 129 for information about
using light path diagnostics LEDs.
• Event logs: See “Event logs” on page 135 for information about notification events and
diagnosis.
• Software or operating-system error codes: See the documentation for the software or
operating system for information about a specific error code. See the manufacturer's website
for documentation.
Step 3. Run Dynamic System Analysis (DSA) and collect system data.
Run Dynamic System Analysis (DSA) to collect information about the hardware, firmware, software,
and operating system. Have this information available when you contact IBM or an approved
warranty service provider. For instructions for running DSA, see the Dynamic System Analysis
Installation and User's Guide.
Fixes or workarounds for many problems might be available in updated UEFI firmware,
device firmware, or device drivers. To display a list of available updates for the server, go to
http://www.ibm.com/support/ fixcentral.
Attention: Installing the wrong firmware or device-driver update might cause the server to
malfunction. Before you install a firmware or device-driver update, read any readme and change
history files that are provided with the downloaded update. These files contain important
information about the update and the procedure for installing the update, including any special
procedure for updating from an early firmware or device-driver version to the latest version.
Important: Some cluster solutions require specific code levels or coordinated code updates. If
the device is part of a cluster solution, verify that the latest level of code is supported for the
cluster solution before you update the code.
a. Install UpdateXpress system updates.
You can install code updates that are packaged as an UpdateXpress System Pack or
UpdateXpress CD image. An UpdateXpress System Pack contains an integration-tested
bundle of online firmware and device-driver updates for your server. In addition, you
can use IBM ToolsCenter Bootable Media Creator to create bootable media that is
suitable for applying firmware updates and running preboot diagnostics. For more
information about UpdateXpress System Packs, see http://www.ibm.com/support/entry/
portal/docdisplay?lndocid=SERV-XPRESS and “Updating the firmware” on page 99. For
more information about the Bootable Media Creator, see https://support.lenovo.com/
us/en/documents/LNVO-BOMC.
Be sure to separately install any listed critical updates that have release dates that are later
than the release date of the UpdateXpress System Pack or UpdateXpress image (see step b).
b. Install manual system updates.
1. Determine the existing code levels.
In DSA, click Firmware/VPD to view system firmware levels, or click Software to view
operating-system levels.
2. Download and install updates of code that is not at the latest level.
To display a list of available updates for the server, go to http://www.ibm.com/support/
fixcentral.
When you click an update, an information page is displayed, including a list of the
problems that the update fixes. Review this list for your specific problem; however, even if
your problem is not listed, installing the update might solve the problem.
Step 5. Check for and correct an incorrect configuration.
If the server is incorrectly configured, a system function can fail to work when you enable it; if you
make an incorrect change to the server configuration, a system function that has been enabled
can stop working.
a. Make sure that all installed hardware and software are supported.
See http://www.lenovo.com/ serverproven/ to verify that the server supports the installed
operating system, optional devices, and software levels. If any hardware or software
component is not supported, uninstall it to determine whether it is causing the problem.
Many configuration problems are caused by loose power or signal cables or incorrectly seated
adapters. You might be able to solve the problem by turning off the server, reconnecting
cables, reseating adapters, and turning the server back on. For information about performing
the checkout procedure, see “About the checkout procedure” on page 126. For information
about configuring the server, see Chapter 3 “Configuration information and instructions” on
page 99.
Step 6. See controller and management software documentation.
If the problem is associated with a specific function (for example, if a RAID hard disk drive is
marked offline in the RAID array), see the documentation for the associated controller and
management or controlling software to verify that the controller is correctly configured.
Problem determination information is available for many devices such as RAID and network
adapters.
Troubleshooting procedures and RETAIN tips document known problems and suggested solutions.
To search for troubleshooting procedures and RETAIN tips, go to http://www.lenovo.com/support.
Step 8. Use the troubleshooting tables.
See “Troubleshooting by symptom” on page 140 to find a solution to a problem that has identifiable
symptoms.
A single problem might cause multiple symptoms. Follow the troubleshooting procedure for the
most obvious symptom. If that procedure does not diagnose the problem, use the procedure for
another symptom, if possible.
If the problem remains, contact IBM or an approved warranty service provider for assistance with
additional problem determination and possible hardware replacement. To open an online service
request, go to http://www.ibm.com/support/ entry/portal/Open_service_request. Be prepared to
provide information about any error codes and collected data.
Undocumented problems
If you have completed the diagnostic procedure and the problem remains, the problem might not have
been previously identified by IBM. After you have verified that all code is at the latest level, all hardware
and software configurations are valid, and no light path diagnostics LEDs or log entries indicate a hardware
component failure, contact IBM or an approved warranty service provider for assistance.
Service bulletins
Lenovo continually updates the support website with the latest tips and techniques that you can use to solve
problem that you might have with the Lenovo System x3650 M4 HD server.
Checkout procedure
The checkout procedure is the sequence of tasks that you should follow to diagnose a problem in the server.
Important: If multiple error codes or light path diagnostics LEDs indicate a microprocessor error, the
error might be in the microprocessor or in the microprocessor socket. See “Microprocessor problems” on
page 145 for information about diagnosing microprocessor problems.
• Before you run DSA, you must determine whether the failing server is part of a shared hard disk drive
cluster (two or more servers sharing external storage devices). If it is part of a cluster, you can run all
diagnostic programs except the ones that test the storage unit (that is, a hard disk drive in the storage
unit) or the storage adapter that is attached to the storage unit. The failing server might be part of a
cluster if any of the following conditions is true:
– You have identified the failing server as part of a cluster (two or more servers sharing external storage
devices).
– One or more external storage units are attached to the failing server and at least one of the attached
storage units is also attached to another server or unidentifiable device.
– One or more servers are located near the failing server.
Important: If the server is part of a shared hard disk drive cluster, run one test at a time. Do not run
any suite of tests, such as “quick” or “normal” tests, because this might enable the hard disk drive
diagnostic tests.
• If the server is halted and a POST error code is displayed, see Appendix B “UEFI/POST diagnostic codes”
on page 953. If the server is halted and no error message is displayed, see “Troubleshooting by symptom”
on page 140 and “Solving undetermined problems” on page 160.
• For information about power-supply problems, see “Solving power problems” on page 157, “Power
problems” on page 149, and “Power-supply LEDs” on page 131.
• For intermittent problems, check the event log; see “Event logs” on page 135 and Appendix C “DSA
diagnostic test results” on page 977.
Diagnostic tools
The section introduces available tools to help you diagnose and solve hardware-related problems.
Note: Use the latest available version of DSA to make sure you are using the most
recent configuration data. For documentation and download information for DSA, see
http://shop.lenovo.com/us/en/systems/solutions/.
For additional information, see “Dynamic System Analysis” on page 137 and Appendix C “DSA
diagnostic test results” on page 977.
– DSA Preboot
DSA Preboot diagnostic program is stored in the integrated USB memory on the server. DSA Preboot
collects and analyzes system information to aid in diagnosing server problems, as well as offering a
rich set of diagnostic tests of the major components of the server. DSA Preboot collects the following
information about the server:
When LEDs are lit to indicate an error, they remain lit when the server is turned off, provided that the server is
still connected to power and the power supply is operating correctly.
Before you work inside the server to view light path diagnostics LEDs, read the safety information “Safety”
on page v and “Handling static-sensitive devices” on page 36.
If an error occurs, view the light path diagnostics LEDs in the following order:
Power-control button/
power-on LED
1 2 3 4
2. Remove the server cover and look inside the server for lit LEDs. Certain components inside the server
have LEDs that are lit to indicate the location of a problem.
Note: You do not have to remove the server cover to view the LEDs on hard disk drives and power
supplies.
The following illustration shows the LEDs on the system board.
Standby power
LED
Dual-port network
adapter LED
System battery
error LED
DIMM 19-24
error LEDs DIMM 1-6
(under the latches) error LEDs
(under the latches)
Microprocessor 2 Microprocessor 1
error LED error LED
Power-supply LEDs
The following minimum configuration is required for the server to start.
• One microprocessor in microprocessor socket 1
• One 2 GB DIMM on the system board
• One power supply
• Power cord
• Four cooling fans
• One PCI riser-card assembly in PCI connector 1
AC power-supply LEDs
Use this information to view AC power-supply LEDs.
The following minimum configuration is required for the DC LED on the power supply to be lit:
• Power supply
• Power cord
Note: You must turn on the server for the DC LED on the power supply to be lit.
The following illustration shows the locations of the power-supply LEDs on the ac power supply.
DC power
LED (green)
Power-supply
error LED (amber)
0000000 0000000
00
000
000
0000000 0000000
00
000
000
0000000 0000000
000
000
000
0000000 0000000
000
0000000 0000000
000
000
000
0000000 0000000
000
000
00
000
00
00
000
0000
The following table describes the problems that are indicated by various combinations of the power-supply
LEDs on an ac power supply and suggested actions to correct the detected problems.
AC power-supply LEDs
AC DC Error (!) Description Action Notes
On On Off Normal operation.
Off Off Off No ac power to the 1. Check the ac power to the This is a normal
server or a problem server. condition when no ac
with the ac power 2. Make sure that the power power is present.
source. cord is connected to a
functioning power source.
3. Restart the server. If the
error remains, check the
power-supply LEDs.
4. If the problem remains,
replace the power-supply.
Off Off On The power supply Replace the power supply.
has failed.
Off On Off The power supply Replace the power supply.
has failed.
Off On On The power supply Replace the power supply.
has failed.
On Off Off Power-supply not 1. Reseat the power supply. Typically indicates a
fully seated, faulty 2. Follow actions in “Power power-supply is not
system board, or problems” on page 149. fully seated.
the power supply
has failed. 3. Follow actions in “Solving
power problems” on page
157 until the problem is
solved.
On Off On The power supply Replace the power supply.
has failed.
On On On The power supply Replace the power supply.
has failed.
The following illustration shows the locations of the power-supply LEDs on the dc power supply.
The following table describes the problems that are indicated by various combinations of the power-supply
LEDs on a dc power supply and suggested actions to correct the detected problems.
DC power-supply LEDs
IN OK OUT OK Error (!) Description Action Notes
On On Off Normal operation.
Off Off Off No dc power to the 1. Check the dc power to the This is a normal
server or a problem server. condition when no dc
with the dc power 2. Make sure that the power power is present.
source. cord is connected to a
functioning power source.
3. Restart the server. If the
error remains, check the
power-supply LEDs.
4. If the problem remains,
replace the power-supply.
Off Off On The power supply Replace the power supply.
has failed.
Off On Off The power supply Replace the power supply.
has failed.
Off On On The power supply Replace the power supply.
has failed.
On Off Off Power-supply not 1. Reseat the power supply. Typically indicates a
fully seated, faulty 2. Follow actions in the “Power power-supply is not
system board, or problems” on page 149. fully seated.
the power supply
has failed. 3. Follow actions in “Solving
power problems” on page
157 until the problem is
solved.
The following LEDs are on the system board and monitor the system power-on and power-off sequencing
and boot progress (see “System-board LEDs” on page 31 for the location of these LEDs).
The following illustration shows the location of the PCI riser-card LEDs.
000
000
0000000
000
0000000
0000000
0000
0000000
00
0000
0000
00
0000
0000
0000
Event logs
Error codes and messages displayed in POST event log, system-event log, integrated management module
(IMM2) event log, and DSA event log.
• POST event log: This log contains the most recent error codes and messages that were generated
during POST. You can view the contents of the POST event log from the Setup utility (see “Starting the
Setup utility” on page 103). For more information about POST error codes, see Appendix B “UEFI/POST
diagnostic codes” on page 953.
• System-event log: This log contains POST and system management interrupt (SMI) events and all
events that are generated by the baseboard management controller that is embedded in the integrated
management module (IMM). You can view the contents of the system-event log through the Setup
utility and through the Dynamic System Analysis (DSA) program (as IPMI event log).The system-event
log is limited in size. When it is full, new entries will not overwrite existing entries; therefore, you must
periodically clear the system-event log through the Setup utility. When you are troubleshooting an error,
you might have to save and then clear the system-event log to make the most recent events available for
analysis. For more information about the system-event log, see Appendix A “Integrated management
module II (IMM2) error messages” on page 303.
Messages are listed on the left side of the screen, and details about the selected message are displayed
on the right side of the screen. To move from one entry to the next, use the Up Arrow (-) and Down
Arrow (¯) keys.
Some IMM sensors cause assertion events to be logged when their setpoints are reached. When a
setpoint condition no longer exists, a corresponding deassertion event is logged. However, not all events
are assertion-type events.
• Integrated management module II (IMM2) event log: This log contains a filtered subset of all IMM,
POST, and system management interrupt (SMI) events. You can view the IMM event log through the IMM
web interface. For more information, see “Logging on to the web interface” on page 113. You can also
view the IMM event log through the Dynamic System Analysis (DSA) program (as the ASM event log).
For more information about IMM error messages, see Appendix A “Integrated management module II
(IMM2) error messages” on page 303.
• DSA event log: This log is generated by the Dynamic System Analysis (DSA) program, and it is a
chronologically ordered merge of the system-event log (as the IPMI event log), the IMM chassis-event log
(as the ASM event log), and the operating-system event logs. You can view the DSA event log through the
DSA program (see “Viewing event logs without restarting the server” on page 136). For more information
If you have installed Dynamic System Analysis (DSA) Portable, you can use it to view the system-event log
(as the IPMI event log), or the IMM event log (as the ASM event log), the operating-system event logs, or the
merged DSA log. You can also use DSA Preboot to view these logs, although you must restart the server to
use DSA Preboot. To install DSA Portable or check for and download a later version of DSA Preboot CD
image, go to https://support.lenovo.com/us/ en/documents/LNVO-DSA.
If IPMItool is installed in the server, you can use it to view the system-event log. Most recent versions
of the Linux operating system come with a current version of IPMItool. For an overview of IPMI, go to
http://www.ibm.com/developerworks/linux/blueprints/ and click Using Intelligent Platform Management
Interface (IPMI) on Lenovo Linux platforms.
You can view the IMM event log through the Event Log link in the integrated management module II (IMM2)
web interface. For more information, see “Logging on to the web interface” on page 113.
The following table describes the methods that you can use to view the event logs, depending on the
condition of the server. The first three conditions generally do not require that you restart the server.
Note: The POST error log is automatically cleared each time the server is restarted.
POST
When you turn on the server, it performs a series of tests to check the operation of the server components
and some optional devices in the server. This series of tests is called the power-on self-test, or POST.
Note: This server does not use beep codes for server status.
If a power-on password is set, you must type the password and press Enter (when you are prompted),
for POST to run.
If POST detects a problem, an error message is displayed. See Appendix B “UEFI/POST diagnostic codes”
on page 953 for more information.
If POST detects a problem, an error message is sent to the POST event log, see “Event logs” on page
135 for more information.
For system-specific information about the action that you should take as a result of a message that DSA
generates, see Appendix C “DSA diagnostic test results” on page 977.
If you cannot find a problem by using DSA, see “Solving undetermined problems” on page 160 for
information about testing the server.
Note: DSA Preboot might appear to be unresponsive when you start the program. This is normal operation
while the program loads.
Make sure that the server has the latest version of the DSA code. To obtain DSA code and the
Dynamic System Analysis Installation and User's Guide, go to https://support.lenovo.com/us/
en/documents/LNVO-DSA.
DSA editions
Two editions of Dynamic System Analysis are available.
• DSA Portable
DSA Portable Edition runs within the operating system; you do not have to restart the server to run it. It is
packaged as a self-extracting file that you download from the web. When you run the file, it self-extracts
to a temporary folder and performs comprehensive collection of hardware and operating-system
information. After it runs, it automatically deletes the temporary files and folder and leaves the results of
the data collection and diagnostics on the server.
If you are unable to restart the server, use DSA Portable.
• DSA Preboot
DSA Preboot runs outside of the operating system; you must restart the server to run it. It is provided in
the flash memory on the server, or you can create a bootable media such as a CD, DVD, ISO, USB, or PXE
using the ToolsCenter Bootable Media Creator (BoMC). For more details, see the BoMC User Guide at
https://support.lenovo.com/ us/en/documents/LNVO-BOMC. In addition to the capabilities of the other
editions of DSA, DSA Preboot includes diagnostic routines that would be disruptive to run within the
operating-system environment (such as resetting devices and causing loss of network connectivity). It
has a graphical user interface that you can use to specify which diagnostics to run and to view the
diagnostic and data collection results.
DSA Preboot provides diagnostics for the following system components, if they are installed:
– Emulex network adapter
– Optical devices (CD or DVD)
– Tape drives (SCSI, SAS, or SATA)
– Memory
Note: The DSA memory test might take up to 30 minutes to run. If the problem is not a memory problem,
skip the memory test.
To run the DSA Preboot diagnostic programs, complete the following steps:
Step 1. If the server is running, turn off the server and all attached devices.
Step 2. Turn on all attached devices; then, turn on the server.
Step 3. When the prompt <F2> Diagnostics is displayed, press F2.
Note: The DSA Preboot diagnostic program might appear to be unresponsive for an unusual
length of time when you start the program. This is normal operation while the program loads. The
loading process may take up to 10 minutes.
Step 4. Optionally, select Quit to DSA to exit from the stand-alone memory diagnostic program.
Note: After you exit from the stand-alone memory diagnostic environment, you must restart the
server to access the stand-alone memory diagnostic environment again.
Step 5. Type gui to display the graphical user interface, or type cmd to display the DSA interactive menu.
Step 6. Follow the instructions on the screen to select the diagnostic test to run.
If the diagnostic programs do not detect any hardware errors but the problem remains during normal server
operation, a software error might be the cause. If you suspect a software problem, see the information
that comes with your software.
A single problem might cause more than one error message. When this happens, correct the cause of the
first error message. The other error messages usually will not occur the next time you run the diagnostic
programs.
If the server stops during testing and you cannot continue, restart the server and try running the DSA
Preboot diagnostic programs again. If the problem remains, replace the component that was being tested
when the server stopped.
Viewing the test log results and transferring the DSA collection
Use this information to view the test log results and transferring the DSA collection.
To view the test log for the results when the tests are completed, click the Success link in the Status column,
if you are running the DSA graphical user interface, or type :x to exit the Execute Tests menu, if you are
running the DSA interactive menu, or select Diagnostic Event Log in the graphical user interface. To transfer
DSA Preboot collections to an external USB device, type the copy command in the DSA interactive menu.
• If you are running the DSA graphical user interface (GUI), click the Success link in the Status column.
• If you are running the DSA interactive menu (CLI), type :x to exit the Execute Tests menu; then, select
completed tests to view the results.
You can also send the DSA error log to the Lenovo support to aid in diagnosing the server problems.
The following sections provide information about the call home tools.
Error messages
This section provides the list of error codes and messages for UEFI/POST, IMM2, and DSA that are
generated when a problem is detected.
See Appendix B “UEFI/POST diagnostic codes” on page 953, Appendix A “Integrated management module
II (IMM2) error messages” on page 303, and Appendix C “DSA diagnostic test results” on page 977 for
more information.
Troubleshooting by symptom
Use the troubleshooting tables to find solutions to problems that have identifiable symptoms.
If you cannot find a solution to the problem in these tables, see Appendix C “DSA diagnostic test results” on
page 977 for information about testing the server and “Running the DSA Preboot diagnostic programs” on
page 139 for additional information about running DSA Preboot program. For additional information to help
you solve problems, see “Start here” on page 123.
If you have just added new software or a new optional device and the server is not working, complete the
following steps before you use the troubleshooting tables:
Step 1. Check the system-error LED on the operator information panel; if it is lit, check the light path
diagnostics LEDs (see “Light path diagnostics” on page 129).
General problems
Use this information to solve general problems.
• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
• Go to the Lenovo support website at http://www.lenovo.com/support to check for technical information,
hints, tips, and new device drivers or to submit a request for information.
Symptom Action
A cover latch is broken, an If the part is a CRU, replace it. If the part is a microprocessor or the system board,
LED is not working, or a similar the part must be replaced by a trained technician.
problem has occurred.
The server is hung while the 1. See “Nx-boot failure” on page 164 for more information.
screen is on. Cannot start the 2. See “Recovering the server firmware (UEFI update failure)” on page 162 for
Setup utility by pressing F1. more information.
• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
• Go to the Lenovo support website at http://www.lenovo.com/support to check for technical information,
hints, tips, and new device drivers or to submit a request for information.
Symptom Action
A hard disk drive has failed, Replace the failed hard disk drive (see “Removing a hot-swap hard disk drive” on
and the associated yellow hard page 210 and “Replacing a hot-swap drive” on page 211).
disk drive status LED is lit.
A newly installed hard disk 1. Make sure that the installed hard disk drive or ServeRAID adapter is supported.
drive is not recognized. For a list of supported optional devices, see http://www.lenovo.com/
serverproven/.
2. Observe the associated yellow hard disk drive status LED. If the LED is lit, it
indicates a drive fault.
3. If the LED is lit, remove the drive from the bay, wait 45 seconds, and reinsert
the drive, making sure that the drive assembly connects to the hard disk drive
backplane.
4. Observe the associated green hard disk drive activity LED and the yellow
status LED:
• If the green activity LED is flashing and the yellow status LED is not lit, the
drive is recognized by the controller and is working correctly. Run the DSA
diagnostics program to determine whether the drive is detected.
• If the green activity LED is flashing and the yellow status LED is flashing
slowly, the drive is recognized by the controller and is rebuilding.
• If neither LED is lit or flashing, check the hard disk drive backplane (go to 5).
• If the green activity LED is flashing and the yellow status LED is lit, replace
the drive. If the activity of the LEDs remains the same, go to 5. If the activity
of the LEDs changes, return to 2.
5. Make sure that the hard disk drive backplane is correctly seated. When it is
correctly seated, the drive assemblies correctly connect to the backplane
without bowing or causing movement of the backplane.
6. Reseat the backplane power cable and repeat steps 2 through 4.
7. Reseat the backplane signal cable and repeat steps 2 through 4.
8. Suspect the backplane signal cable or the backplane:
• If the server has eight hot-swap bays:
a. Replace the affected backplane signal cable.
b. Replace the affected backplane.
9. See “Problem determination tips” on page 160.
Multiple hard disk drives fail. Make sure that the hard disk drive, SAS/SATA adapter, and server device drivers
and firmware are at the latest level.
Important: Some cluster solutions require specific code levels or coordinated code
updates. If the device is part of a cluster solution, verify that the latest level of code
is supported for the cluster solution before you update the code.
Multiple hard disk drives are 1. Review the storage subsystem logs for indications of problems within the
offline. storage subsystem, such as backplane or cable problems.
2. See “Problem determination tips” on page 160.
A replacement hard disk drive 1. Make sure that the hard disk drive is recognized by the adapter (the green hard
does not rebuild. disk drive activity LED is flashing).
2. Review the SAS/SATA adapter documentation to determine the correct
configuration parameters and settings.
A green hard disk drive activity If the green hard disk drive activity LED does not flash when the drive is in use, run
LED does not accurately the DSA Preboot diagnostic programs to collect error logs (see “Running the DSA
represent the actual state of Preboot diagnostic programs” on page 139).
the associated drive.
• If there is a hard disk drive error log, replace the affected hard disk drive.
• If there is no disk drive error log error log, replace the affected backplane.
An yellow hard disk drive 1. If the yellow hard disk drive LED and the RAID adapter software do not indicate
status LED does not accurately the same status for the drive, complete the following steps:
represent the actual state of a. Turn off the server.
the associated drive.
b. Reseat the SAS/SATA adapter.
c. Reseat the backplane signal cable and backplane power cable.
d. Reseat the hard disk drive.
e. Turn on the server and observe the activity of the hard disk drive LEDs.
2. See “Problem determination tips” on page 160.
• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
• Go to the Lenovo support website at http://www.lenovo.com/support to check for technical information,
hints, tips, and new device drivers or to submit a request for information.
Symptom Action
If an optional embedded 1. Make sure that the optional embedded hypervisor flash device is selected on
hypervisor flash device is not the boot manager <F12> Select Boot Device at startup.
listed in the expected boot 2. Make sure that the embedded hypervisor flash device is seated in the connector
order, does not appear in the correctly (see “Removing a USB embedded hypervisor flash device” on page
list of boot devices, or a similar 264 and “Replacing a USB embedded hypervisor flash device” on page 265).
problem has occurred.
3. See the documentation that comes with the optional embedded hypervisor
flash device for setup and configuration information.
4. Make sure that other software works on the server.
Intermittent problems
Use this information to solve intermittent problems.
• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
• Go to the Lenovo support website at http://www.lenovo.com/support to check for technical information,
hints, tips, and new device drivers or to submit a request for information.
Symptom Action
A problem occurs only 1. Make sure that:
occasionally and is difficult to • All cables and cords are connected securely to the rear of the server and
diagnose. attached devices.
• When the server is turned on, air is flowing from the fan grille. If there is
no airflow, the fan is not working. This can cause the server to overheat
and shut down.
2. Check the system-error log or IMM event logs (see “Event logs” on page 135).
The server resets (restarts) 1. If the reset occurs during POST and the POST watchdog timer is enabled (click
occasionally. System Settings ➙ Recovery ➙ System Recovery ➙ POST Watchdog Timer
in the Setup utility to see the POST watchdog setting), make sure that sufficient
time is allowed in the watchdog timeout value (POST Watchdog Timer). If the
server continues to reset during POST, see Appendix B “UEFI/POST diagnostic
codes” on page 953 and Appendix C “DSA diagnostic test results” on page 977.
2. If neither condition applies, check the system-error log or IMM system-event
log (see “Event logs” on page 135).
Memory problems
Use this information to solve memory problems.
• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
• Go to the Lenovo support website at http://www.lenovo.com/support to check for technical information,
hints, tips, and new device drivers or to submit a request for information.
Symptom Action
The amount of system memory Note: Each time you install or remove a DIMM, you must disconnect the server from
that is displayed is less than the power source; then, wait 10 seconds before restarting the server.
the amount of installed physical 1. Make sure that:
memory.
• No error LEDs are lit on the operator information panel.
• No DIMM error LEDs are lit on the system board.
• Memory mirrored channel does not account for the discrepancy.
• The memory modules are seated correctly.
• You have installed the correct type of memory.
• If you changed the memory, you updated the memory configuration in the
Setup utility.
• All banks of memory are enabled. The server might have automatically
disabled a memory bank when it detected a problem, or a memory bank
might have been manually disabled.
Microprocessor problems
Use this information to solve microprocessor problems.
Some Lenovo monitors have their own self-tests. If you suspect a problem with your monitor, see the
documentation that comes with the monitor for instructions for testing and adjusting the monitor. If you
cannot diagnose the problem, call for service.
• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
• Go to the Lenovo support website at http://www.lenovo.com/support to check for technical information,
hints, tips, and new device drivers or to submit a request for information.
Symptom Action
Testing the monitor. 1. Make sure that the monitor cables are firmly connected.
2. Try using a different monitor on the server, or try using the monitor that is being
tested on a different server.
3. Run the diagnostic programs. If the monitor passes the diagnostic programs,
the problem might be a video device driver.
4. (Trained technician only) Replace the system board.
The screen is blank. 1. If the server is attached to a KVM switch, bypass the KVM switch to eliminate it
as a possible cause of the problem: connect the monitor cable directly to the
correct connector on the rear of the server.
2. The IMM2 remote presence function is disabled if you install an optional video
adapter. To use the IMM2 remote presence function, remove the optional video
adapter.
3. If the server installed with the graphical adapters while turning on the server,
the Lenovo logo displays on the screen after approximately 3 minutes. This is
normal operation while the system loads.
4. Make sure that:
a. To prevent diskette drive read/write errors, make sure that the distance
between the monitor and any external diskette drive is at least 76 mm (3 in.).
b. Non-Lenovo monitor cables might cause unpredictable problems.
2. Reseat the monitor cable.
3. Replace the components listed in step 2 one at a time, in the order shown,
restarting the server each time:
a. Monitor cable
• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
• Go to the Lenovo support website at http://www.lenovo.com/support to check for technical information,
hints, tips, and new device drivers or to submit a request for information.
Symptom Action
Unable to wake the server 1. If you are using the dual-port network adapter and the server is connected to
using the Wake on LAN feature. the network using Ethernet 5 connector, check the system-error log or IMM2
system event log (see “Event logs” on page 135), make sure:
a. Fan 3 is running in standby mode, if Emulex dual port 10GBase-T embedded
adapter is installed.
b. The room temperature is not too high (see “Server features and
specifications” on page 6).
c. The air vents are not blocked.
d. The air baffle is installed securely.
2. Reseat the dual-port network adapter (see “Removing the dual-port network
adapter” on page 235 and “Replacing the dual-port network adapter” on page
237).
3. Turn off the server and disconnect it from the power source; then, wait 10
seconds before restarting the server.
4. If the problem still remains, replace the dual-port network adapter.
Log in failed by using LDAP 1. Make sure the license key is valid.
account with SSL enabled. 2. Generate a new license key and log in again.
• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
• Go to the Lenovo support website at http://www.lenovo.com/support to check for technical information,
hints, tips, and new device drivers or to submit a request for information.
Symptom Action
An Lenovo optional device that 1. Make sure that:
was just installed does not • The device is designed for the server (see http://www.lenovo.com/
work. serverproven/).
• You followed the installation instructions that came with the device and the
device is installed correctly.
• You have not loosened any other installed devices or cables.
• You updated the configuration information in the Setup utility. Whenever
memory or any other device is changed, you must update the configuration.
2. Reseat the device that you just installed.
3. Replace the device that you just installed.
An Lenovo optional device that 1. Make sure that all of the cable connections for the device are secure.
worked previously does not 2. If the device comes with test instructions, use those instructions to test the
work now. device.
3. If the failing device is a SCSI device, make sure that:
• The cables for all external SCSI devices are connected correctly.
• The last device in each SCSI chain, or the end of the SCSI cable, is
terminated correctly.
• Any external SCSI device is turned on. You must turn on an external SCSI
device before you turn on the server.
4. Reseat the failing device.
5. Replace the failing device.
Power problems
Use this information to solve power problems.
Symptom Action
The power-control button does 1. Verify that input power is applied to the server and that the power supplies are
not work, and the reset button functioning:
does not work (the server does a. Make sure that both power supplies installed in the server are of the same
not start). type. Mixing different power supplies in the server will cause a system error.
Note: The power-control
button will not function until b. Make sure that the power cords are correctly connected to the server and to
approximately 5 to 10 seconds a working electrical outlet. The power source meets the input power
requirements for the installed power supplies (see the power supply labels).
after the server has been
connected to power. c. Make sure that the LEDs on the power supplies do not indicate a problem.
See “Power-supply LEDs” on page 131.
2. Make sure that the power-control button and the reset button are working
correctly:
a. Disconnect the server power cords.
b. Reconnect the power cords.
c. (Trained technician only) Reseat the operator information panel cable, and
then repeat steps a and b.
d. (Trained technician only) If the problem remains, reseat the operator
information panel.
e. (Trained technician only) If the problem still remains, replace the operator
information panel.
3. Make sure that:
• The type of memory that is installed is correct.
• The processors are installed in the correct sequence.
• The minimum number of DIMMs are installed and functional for your
processor configuration.
4. If you just installed an optional device, remove it, and restart the server. If the
server now starts, you might have installed more devices than the power supply
supports.
5. If the problem still remains, see “Solving undetermined problems” on page 160.
6. If everything is done but the issue still cannot be resolved, please collect the
failure information with system logs captured to Lenovo support.
• Hard disk drive backplane (see “Removing the hot-swap drive backplane” on
page 260 and “Replacing the hot-swap drive backplane” on page 261).
• Hard disk drives (see “Removing a hot-swap hard disk drive” on page 210
and “Replacing a hot-swap drive” on page 211).
• Hard disk drive power cable (see “Removing the hot-swap drive backplane”
on page 260 and “Replacing the hot-swap drive backplane” on page 261).
or
• PCI riser-card assembly 2 (see “Removing a PCI riser-card assembly” on
page 221 and “Replacing a PCI riser-card assembly” on page 222).
• Adapters installed in PCI riser-card assembly 2 (see “Removing an adapter”
on page 226 and “Replacing an adapter” on page 228).
• PCI adapter power cable (see “Removing an adapter” on page 226 and
“Replacing an adapter” on page 228).
5. Follow actions in “Solving power problems” on page 157, if the system-error
LED on the operator information panel is still lit.
6. Replace the power supply if the system-error LED on the operator information
panel is still lit.
The server does not turn off. 1. Determine whether you are using an Advanced Configuration and Power
Interface (ACPI) or a non-ACPI operating system. If you are using a non-ACPI
operating system, complete the following steps:
a. Press Ctrl+Alt+Delete.
b. Turn off the server by pressing the power-control button and hold it down for
5 seconds.
c. Restart the server.
d. If the server fails POST and the power-control button does not work,
disconnect the power cord for 20 seconds; then, reconnect the power cord
and restart the server.
2. If the problem remains or if you are using an ACPI-aware operating system,
suspect the system board.
The server unexpectedly shuts See “Solving undetermined problems” on page 160.
down, and the LEDs on the
operator information panel are
not lit.
Serial-device problems
Use this information to solve serial-device problems.
ServerGuide problems
Use this information to solve ServerGuide problems.
• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
• Go to the Lenovo support website at http://www.lenovo.com/support to check for technical information,
hints, tips, and new device drivers or to submit a request for information.
Symptom Action
The MegaRAID Storage 1. Make sure that the hard disk drive is connected correctly.
Manager program cannot 2. Make sure that the SAS/SATA hard disk drive cables are securely connected.
view all installed drives, or the
operating system cannot be
installed.
The operating-system Make more space available on the hard disk.
installation program
continuously loops.
The ServerGuide program will Make sure that the operating-system CD is supported by the ServerGuide
not start the operating-system program. For a list of supported operating-system versions, go to
CD. http://www.ibm.com/support/entry/portal/ docdisplay?lndocid=SERV-GUIDE, click
the link for your ServerGuide version, and scroll down to the list of supported
Microsoft Windows operating systems.
The operating system cannot Make sure that the server supports the operating system. If it does, either no logical
be installed; the option is not drive is defined (SCSI RAID servers), or the ServerGuide System Partition is not
available. present. Run the ServerGuide program and make sure that setup is complete.
• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
• Go to the Lenovo support website at http://www.lenovo.com/support to check for technical information,
hints, tips, and new device drivers or to submit a request for information.
Symptom Action
You suspect a software 1. To determine whether the problem is caused by the software, make sure that:
problem. • The server has the minimum memory that is needed to use the software. For
memory requirements, see the information that comes with the software.
If you have just installed an adapter or memory, the server might have a
memory-address conflict.
• The software is designed to operate on the server.
• Other software works on the server.
• The software works on another server.
2. If you received any error messages when using the software, see the information
that comes with the software for a description of the messages and suggested
solutions to the problem.
3. Contact the software vendor.
• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
• Go to the Lenovo support website at http://www.lenovo.com/support to check for technical information,
hints, tips, and new device drivers or to submit a request for information.
Symptom Action
A USB device does not work. 1. Make sure that:
• The correct USB device driver is installed.
• The operating system supports USB devices.
2. Make sure that the USB configuration options are set correctly in the Setup
utility (see “Using the Setup utility” on page 103 for more information).
3. If you are using a USB hub, disconnect the USB device from the hub and
connect it directly to the server.
Video problems
Use this information to solve video problems.
Step 1. Turn off the server and disconnect all power cords.
Step 2. Check for loose cables in the power subsystem. Also check for short circuits, for example, if a
loose screw is causing a short circuit on a circuit board.
Step 3. Check the lit LEDs on the operator information panel (see “Light path diagnostics” on page 129).
Step 4. If the check log LED on the light path diagnostics panel is lit, check the IMM event log for faulty
Pwr rail and complete the following steps. Table 15 “Components associated with power rail
errors” on page 158 identifies the components that are associated with each Pwr rail and the
order in which to troubleshoot the components.
a. Disconnect the cables and power cords to all internal and external devices (see “Internal cable
routing and connectors” on page 179). Leave the power-supply cords connected.
b. For Pwr rail A error, complete the following steps:
1. (Trained technician only) Replace the system board.
2. (Trained technician only) Replace the microprocessor.
c. For other rail errors (Pwr rail A error, see step b), remove each component that is associated
with the faulty Pwr rail, one at a time, in the sequence indicated in Table 15 “Components
associated with power rail errors” on page 158, restarting the server each time, until the
cause of the overcurrent condition is identified.
If the server does not start from the minimum configuration, see “Power-supply LEDs” on page 131 to
replace the components in the minimum configuration one at a time until the problem is isolated.
The method that you use to test the Ethernet controller depends on which operating system you are using.
See the operating-system documentation for information about Ethernet controllers, and see the Ethernet
controller device-driver readme file.
Step 1. Make sure that the correct device drivers, which come with the server are installed and that they
are at the latest level.
Step 2. Make sure that the Ethernet cable is installed correctly.
• The cable must be securely attached at all connections. If the cable is attached but the problem
remains, try a different cable.
• If you set the Ethernet controller to operate at 100 Mbps, you must use Category 5 cabling.
• If you directly connect two servers (without a hub), or if you are not using a hub with X ports,
use a crossover cable. To determine whether a hub has an X port, check the port label. If the
label contains an X, the hub has an X port.
Step 3. Determine whether the hub supports auto-negotiation. If it does not, try configuring the integrated
Ethernet controller manually to match the speed and duplex mode of the hub.
Step 4. Check the Ethernet controller LEDs on the rear panel of the server. These LEDs indicate whether
there is a problem with the connector, cable, or hub.
If the Ethernet controller still cannot connect to the network but the hardware appears to be working, the
network administrator must investigate other possible causes of the error.
If you suspect that a software problem is causing failures (continuous or intermittent), see “Software
problems” on page 157.
Corrupted data in CMOS memory or corrupted UEFI firmware can cause undetermined problems. To reset
the CMOS data, use the CMOS clear jumper (JP1) to clear the CMOS memory and override the power-on
password; see Table 3 “System board jumpers” on page 30 for more information. If you suspect that the
UEFI firmware is corrupted, see “Recovering the server firmware (UEFI update failure)” on page 162.
If the power supplies are working correctly, complete the following steps:
If the problem is solved when you remove an adapter from the server but the problem recurs when you
reinstall the same adapter, suspect the adapter; if the problem recurs when you replace the adapter with
a different one, suspect the riser card.
If you suspect a networking problem and the server passes all the system tests, suspect a network cabling
problem that is external to the server.
The model name and serial number are located on the ID label on the front of the server as shown in
the following illustration.
Note: The illustrations in this document might differ slightly from your hardware.
ID label
You can solve some problems by comparing the configuration and software setups between working and
nonworking servers. When you compare servers to each other for diagnostic purposes, consider them
identical only if all the following factors are exactly the same in all the servers:
• Machine type and model
• UEFI firmware level
• IMM firmware level
• Adapters and attachments, in the same locations
• Address jumpers, terminators, and cabling
• Software versions and levels
See Appendix D “Getting help and technical assistance” on page 1135 for information about calling Lenovo
for service.
Important: Some cluster solutions require specific code levels or coordinated code updates. If the device
is part of a cluster solution, verify that the latest level of code is supported for the cluster solution before
you update the code.
If the server firmware has become corrupted, such as from a power failure during an update, you can
recover the server firmware in the following way:
• In-band method: Recover server firmware, using either the boot block jumper (Automated Boot
Recovery) and a server Firmware Update Package Service Pack.
• Out-of-band method: Use the IMM web interface to update the firmware, using the latest server
firmware update package.
Notes: You can obtain a server update package from one of the following sources:
• Download the server firmware update from the World Wide Web.
• Contact your Lenovo service representative.
To download the server firmware update package from the World Wide Web, go to
http://www.lenovo.com/support.
The flash memory of the server consists of a primary bank and a backup bank. You must maintain a bootable
UEFI firmware image in the backup bank. If the server firmware in the primary bank becomes corrupted, you
can either manually boot the backup bank with the UEFI boot backup jumper (JP7), or in the case of image
corruption, this will occur automatically with the Automated Boot Recovery function.
To recover the server firmware and restore the server operation to the primary bank, complete the following
steps:
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Turn off the server, and disconnect all power cords and external cables.
Step 3. Remove the cover (see “Removing the cover” on page 37).
Step 4. Locate the UEFI boot backup jumper (JP7) on the system board.
CMOS clear
jumper (JP1)
Step 5. Move the UEFI boot backup jumper (JP7) from pins 1 and 2 to pins 2 and 3 to enable the UEFI
recovery mode.
Step 6. Reinstall the server cover; then, reconnect all power cords.
Step 7. Restart the server. The system begins the power-on self-test (POST).
Step 8. Boot the server to an operating system that is supported by the firmware update package that
you downloaded.
Step 9. Perform the firmware update by following the instructions that are in the firmware update package
readme file.
Step 10. Turn off the server and disconnect all power cords and external cables, and then remove the
cover (see “Removing the cover” on page 37).
Step 11. Move the UEFI boot backup jumper (JP7) from pins 2 and 3 back to the primary position (pins 1
and 2).
Step 12. Reinstall the cover (see “Replacing the cover” on page 196).
Step 13. Reconnect the power cord and any cables that you removed.
Step 14. Restart the server. The system begins the power-on self-test (POST). If this does not recover the
primary bank, continue with the following steps.
Step 15. Remove the cover (see “Removing the cover” on page 37).
Step 16. Reset the CMOS by removing the system battery (see “Removing the system battery” on page 266).
Step 17. Leave the system battery out of the server for approximately 5 to 15 minutes.
Step 18. Reinstall the system battery (see “Replacing the system battery” on page 269).
Step 19. Reinstall the cover (see “Replacing the cover” on page 196).
Note: Use this method if the system-error LED on the operator information panel is lit and there is a log
entry or Booting Backup Image is displayed on the firmware splash screen; otherwise, use the in-band
manual recovery method.
Step 1. Boot the server to an operating system that is supported by the firmware update package that
you downloaded.
Step 2. Perform the firmware update by following the instructions that are in the firmware update package
readme file.
Step 3. Restart the server.
Step 4. At the firmware splash screen, press F3 when prompted to restore to the primary bank. The
server boots from the primary bank.
Out-of-band method
Use this information to use the out-of-band method.
For instructions for recovering the UEFI firmware, see “Recovering the server firmware (UEFI update failure)”
on page 162. After you have recovered the firmware in the primary bank, complete the following steps:
Nx-boot failure
Configuration changes, such as added devices or adapter firmware updates, and firmware or application
code problems can cause the server to fail POST (the power-on self-test).
After a specified number of consecutive attempts (automatic or manual), the Nx-boot failure feature causes
the server to revert to the default UEFI configuration and start the Setup utility so that you can make the
To specify the number of consecutive restart attempts that will trigger the Nx-boot failure feature, in the
Setup utility, click System Settings ➙ Recovery ➙ POST Attempts ➙ POST Attempts Limit. The available
options are 3, 6, 9, and 255 (disable Nx-boot failure).
• Structural parts: Purchase and replacement of structural parts (components, such as chassis assembly,
top cover, and bezel) is your responsibility. If Lenovo acquires or installs a structural component at
your request, you will be charged for the service. See “Structural parts” on page 174 for the list of
structural parts.
• Tier 1 customer replaceable unit (CRU): Replacement of Tier 1 CRUs is your responsibility. If Lenovo
installs a Tier 1 CRU at your request, you will be charged for the installation.
• Tier 2 customer replaceable unit: You may install a Tier 2 CRU yourself or request Lenovo to install it, at
no additional charge, under the type of warranty service that is designated for your server.
For information about the terms of the warranty and getting service and assistance, see the Warranty
Information document that comes with the server. For more information about getting service and
assistance, see Appendix D “Getting help and technical assistance” on page 1135.
The following illustration shows the major components in the server. The illustrations in this document might
differ slightly from your hardware. For a list of structural parts, see “Structural parts” on page 174.
00000000
00000000
00000000
00000000
2
26
0000
0000
0000
0000
00
0000
25 000
000
4
00000
00000
00000
00
24
23 6
8
22
21
10
11
20 14 0
12
0
13
19 000
000
000
15
18
17 16
The following table lists the part numbers for the server replaceable components.
Structural parts
Structural parts are not covered by the Lenovo Statement of Limited Warranty.
The following structural parts are available for purchase from the retail store.
Note: Changes are made periodically to the Lenovo website. The actual procedure might vary slightly
from what is described in this document.
If you need help with your order, call the toll-free number that is listed on the retail parts page, or contact
your Lenovo sales representative or Lenovo reseller for assistance.
Power cords
For your safety, a power cord with a grounded attachment plug is provided to use with this product. To avoid
electrical shock, always use the power cord and plug with a properly grounded outlet.
For your safety, a power cord with a grounded attachment plug is provided to use with this product. To avoid
electrical shock, always use the power cord and plug with a properly grounded outlet.
Lenovo power cords used in the United States and Canada are listed by Underwriter's Laboratories (UL) and
certified by the Canadian Standards Association (CSA).
For units intended to be operated at 230 volts (U.S. use): Use a UL-listed and CSA-certified cord set
consisting of a minimum 18 AWG, Type SVT or SJT, three-conductor cord, a maximum of 15 feet in length
and a tandem blade, grounding-type attachment plug rated 15 amperes, 250 volts.
For units intended to be operated at 230 volts (outside the U.S.): Use a cord set with a grounding-type
attachment plug. The cord set should have the appropriate safety approvals for the country in which the
equipment will be installed.
Power cords for a specific country or region are usually available only in that country or region.
Antigua and Barbuda, Aruba, Bahamas, Barbados, Belize, Bermuda, Bolivia, Caicos
Islands, Canada, Cayman Islands, Colombia, Costa Rica, Cuba, Dominican Republic,
Ecuador, El Salvador, Guam, Guatemala, Haiti, Honduras, Jamaica, Mexico,
Micronesia (Federal States of), Netherlands Antilles, Nicaragua, Panama, Peru,
Philippines, Saudi Arabia, Thailand, Taiwan, United States of America, Venezuela
Antigua and Barbuda, Aruba, Bahamas, Barbados, Belize, Bermuda, Bolivia, Caicos
Islands, Canada, Cayman Islands, Colombia, Costa Rica, Cuba, Dominican Republic,
Ecuador, El Salvador, Guam, Guatemala, Haiti, Honduras, Jamaica, Mexico,
Micronesia (Federal States of), Netherlands Antilles, Nicaragua, Panama, Peru,
Philippines, Saudi Arabia, Thailand, Taiwan, United States of America, Venezuela
39M5219 Korea (Democratic People’s Republic of), Korea (Republic of)
39M5199 Japan
39M5068 Argentina, Paraguay, Uruguay
39M5226 India
39M5240 Brazil
• Structural parts: Purchase and replacement of structural parts (components, such as chassis assembly,
top cover, and bezel) is your responsibility. If Lenovo acquires or installs a structural component at
your request, you will be charged for the service.
• Tier 1 customer replaceable unit (CRU): Replacement of Tier 1 CRUs is your responsibility. If Lenovo
installs a Tier 1 CRU at your request, you will be charged for the installation.
• Tier 2 customer replaceable unit: You may install a Tier 2 CRU yourself or request Lenovo to install it, at
no additional charge, under the type of warranty service that is designated for your server.
See Chapter 5 “Parts listing, Lenovo System x3650 M4 HD Type 5460” on page 167 to determine whether a
component is a structural part, Tier 1 CRU, or Tier 2 CRU.
For information about the terms of the warranty, see the Warranty Information document that comes with
the server.
For more information about getting service and assistance, see Appendix D “Getting help and technical
assistance” on page 1135.
For more information about the requirements for cables and connecting devices, see the documentation
that comes with these devices.
The following illustration shows the internal routing and connectors for the front USB and video cable.
00000000
0000000
00000000
0000000
The following notes describe additional information you must consider when you install or remove the
operator information panel cable:
• You may remove the optional optical drive cable to obtain more room before you install or remove the
operator information panel cable.
• To remove the operator information panel cable, slightly press the cable toward the fan cage; then, pull to
remove the cable from the connector on the system board. Pulling the cable out of the connector by
excessive force might cause damage to the cable or connector.
• To connect the operator information panel cable on the system board, press evenly on the cable. Pressing
on one side of the cable might cause damage to the cable or connector.
Attention: Failing to install or remove the cable with care may damage the connectors on the system board.
Any damage to the connectors may require replacing the system board.
00000000
0000000
00000000
0000000
Operator information
panel cable
The following illustration shows the internal routing and connectors for the video graphic adapter cables.
00000000
000000
00000000
000000
Video graphic
adapter power
cables
Cabling backplane
The internal routing and connectors for the backplanes.
Attention: Please note that the mini-SAS cables for some systems do not connect to the system board but
to the RAID adapters.
The following illustration shows the internal routing and connectors for the 16x2.5-inch hot-swap HDD model.
0000000000
00000000000
0000000000
00000000000
0000000000
00000000000
0000000000
Configuration cable
Mini-SAS cable
Power cable
The following illustration shows the internal routing and connectors for the 16x2.5-inch hot-swap HDD
model cables.
Configuration
cables
Configuration
cable Backplane
Mini-SAS cable
Power
cable
Backplane
connection
cable
Power
cable
The following illustration shows the internal routing and connectors for the 24x2.5-inch hot-swap HDD
model with expander.
0000000000
0000000000
0000000000
0000000000
0000000000
0000000000
0000000000
SAS 1
SAS 0
Power cable
Configuration cable
Mini-SAS cable
Power cable
Configuration cable
Figure 106. 24x2.5-inch hot-swap HDD model with expander cable connection
The following illustration shows the internal routing and connectors for the 24x2.5-inch hot-swap HDD
model with expander cables.
Expander
Configuration
cable
Configuration
cable Backplane
Mini-SAS cable Backplane
connection Power
cable cable
Backplane
connection
cable
Power
cable
Figure 107. 24x2.5-inch hot-swap HDD model with expander cable connection
The following illustration shows the internal routing and connectors for the 24x2.5-inch hot-swap HDD model.
Note: Make sure that Port 1 on the hardware ServeRAID is connected to Port 1 on the backplane. Likewise,
Port 0 on the hardware ServeRAID should be connected to Port 0 on the backplane.
00000000000
000000000
00000000000
000000000
00000000000
000000000
Port 1
SAS 1
Port 0
SAS 0
Power cable
Configuration cable
Mini-SAS cable
Power cable
Configuration cable
Figure 108. 24x2.5-inch hot-swap HDD model cable connection (applicable to FLATWOODS ServeRAID M5210
SAS/SATA Controller)
00000000000
000000000
00000000000
000000000
00000000000
000000000
Port 0
SAS 1
Port 1
SAS 0
Power cable
Configuration cable
Mini-SAS cable
Power cable
Configuration cable
Figure 109. 24x2.5-inch hot-swap HDD model cable connection (applicable to RACINE RAID N2215 controller)
The following illustration shows the internal routing and connectors for the 24x2.5-inch hot-swap HDD
model cables.
Backplane
Configuration
cable
Expander
Configuration
cable
Power
cable
The following illustration shows the internal routing and connectors for the 24x2.5-inch hot-swap HDD model.
Note: Make sure that Port 1 on the hardware ServeRAID is connected to Port 1 on the backplane. Likewise,
Port 0 on the hardware ServeRAID should be connected to Port 0 on the backplane.
Riser 2
0000000000
0000000000
0000000000
0000000000
0000000000
0000000000
0000000000
0000000000
Port 1
SAS 1
Port 0
SAS 0
Power cable
Configuration cable
Mini-SAS cable
Power cable
Configuration cable
Figure 111. 24x2.5-inch hot-swap HDD model cable connection (applicable to FLATWOODS ServeRAID M5210
SAS/SATA Controller)
Riser 2
0000000000
0000000000
0000000000
0000000000
0000000000
0000000000
0000000000
0000000000
Port 0
SAS 1
Port 1
SAS 0
Power cable
Configuration cable
Mini-SAS cable
Power cable
Configuration cable
Figure 112. 24x2.5-inch hot-swap HDD model cable connection (applicable to RACINE RAID N2215 controller)
The following illustration shows the internal routing and connectors for the 24x2.5-inch hot-swap HDD
model cables.
Backplane
Configuration
cable
Backplane
Configuration
cable
The following illustration shows the internal routing and connectors for the 16x2.5-inch and 16x1.8-inch
drive model.
Note: Make sure that Port 1 on the hardware ServeRAID is connected to Port 1 on the backplane. Likewise,
Port 0 on the hardware ServeRAID should be connected to Port 0 on the backplane.
Riser 2
00000000000
0000000000
00000000000
0000000000
00000000000
0000000000
00000000000
0000000000
Port 1
SAS 1
Port 0
SAS 0
Power cable
Configuration cable
Mini-SAS cable
Power cable
Configuration cable
Figure 114. 16x2.5-inch and 16x1.8-inch drive model cable connection (applicable to FLATWOODS ServeRAID M5210
SAS/SATA Controller)
Riser 2
00000000000
0000000000
00000000000
0000000000
00000000000
0000000000
00000000000
0000000000
Port 0
SAS 1
Port 1
SAS 0
Power cable
Configuration cable
Mini-SAS cable
Power cable
Configuration cable
Figure 115. 16x2.5-inch and 16x1.8-inch drive model cable connection (applicable to RACINE RAID N2215 controller)
The following illustration shows the internal routing and connectors for the 16x2.5-inch and 16x1.8-inch
drive model cables.
Mini-SAS cable
1.8-inch backplane assembly
Configuration
cable
Expander
Configuration
Configuration
cable Power cable
cable
Configuration
Backplane
cable Power
cable
Power
cable
The illustrations in this document might differ slightly from your hardware.
Step 1. Read the safety information that begins on page “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Turn off the server and peripheral devices and disconnect the power cords and all external cables,
if necessary.
Step 3. If the server has been installed in a rack, slide the server out from the rack enclosure.
1 0
000000000000
000000000000
000000000000
000000000000
000000000000
3
0
000000000000
000000000000
Step 4. Pull up firmly on the blue latch on the top (in the center of the front of the server) of the cover and
slide the cover toward the rear of the server until the cover has disengaged from the chassis.
Step 5. Lift the server cover off the server and set it aside.
Attention: For proper cooling and airflow, replace the server cover before you turn on the server.
Step 1. Make sure that all cables, adapters, and other components are installed and seated correctly
and that you have not left loose tools or parts inside the server. Also, make sure that all internal
cables are correctly routed.
Before you slide the cover forward, make sure that all the tabs on the front, rear, and side of the
cover engage the chassis correctly. If all the tabs do not engage the chassis correctly, it will be
very difficult to remove the cover later.
Step 2. Position the cover on top of the server.
Step 3. Slide the cover toward the front of the server.
Step 4. Make sure that the cover correctly engages all the inset tabs on the server.
Step 5. Press down the blue latch on the top of the cover.
000000000000
000000000000
000000000000
000000000000
1
0
000000000000
000000000000
000000000000
Step 6. Slide the server all the way into the rack until it latches.
Step 7. Reconnect the external cables and power cords.
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Remove all the cables that are connected to the front of the server.
Step 3. Remove the screws from the bezel.
Step 4. Rotate the top of the bezel away from the server.
Step 5. Remove the operator information panel assembly (see “Removing the operator information panel
assembly” on page 278).
If you are instructed to return the bezel, follow all packaging instructions, and use any packaging materials
for shipping that are supplied to you.
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Turn off the server and peripheral devices and disconnect the power cords and all external cables,
if necessary.
Step 3. Reinstall the operator information panel assembly in the bezel, if it has been removed earlier (see
“Replacing the operator information panel assembly” on page 279).
Step 4. Insert the tabs on the bottom of the bezel into the slots on the underside of the chassis and attach
it with the screws.
Step 5. Connect any cables you previously removed from the front of the server.
Step 1. Read the safety information that begins on page “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Turn off the server and peripheral devices and disconnect the power cords and all external cables
(see “Turning off the server” on page 23).
Step 3. Remove the cover (see “Removing the cover” on page 195).
Step 4. Remove PCI riser-card assemblies, if necessary (see “Removing a PCI riser-card assembly” on
page 221).
Step 5. Place your fingers under the front and back of the top of the air baffle; then, lift the air baffle
out of the server.
000000
000000
0000
000000
0000
00
0000
00
PCI riser-card
assembly 1
000
000000
000
000000
000000
000
000000
000
0
Air baffle
000
0000
0000
Attention: For proper cooling and airflow, replace the air baffle before you turn on the server.
Operating the server with the air baffle removed might damage server components.
Step 1. Read the safety information that begins on page “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Turn off the server and peripheral devices and disconnect the power cords and all external cables.
Step 3. Remove the cover (see “Removing the cover” on page 195).
Step 4. Align the air baffle pins with the baffle pin holes on both sides of the chassis; then, lower the air
baffle into the server. Press the air baffle down until it is securely seated.
Note: Close the retaining clip on each end of the DIMM connector before installing the air baffle for
proper cooling.
000000
000000
0000
000000
0000
00
0000
00
PCI riser-card
assembly 1
000
000000
000
000000
000000
000
000000
000
0
Air baffle
000
0000
0000
If a RAID adapter battery or flash power module is installed near the fan cage and you need to replace it,
complete the following steps:
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Turn off the server and peripheral devices and disconnect all power cords.
Step 3. Remove the cover (see “Removing the cover” on page 195).
Step 4. Push the tab to open the cover on top of the air baffle.
Step 5. Lift the battery or flash power module up to remove it from the holder.
Battery / flash
power module cable
connector
Attention: Make sure that the cable is not pinched and does not cover any connectors or obstruct
any components on the system board.
Step 6. Disconnect the cable from the battery.
Note: You don't have to disconnect the cable from the flash power module.
If you are instructed to return the RAID adapter battery or flash power module, follow all packaging
instructions, and use any packaging materials for shipping that are supplied to you.
Important:
• The battery must recharge for at least 6 hours under normal operating conditions. To protect your data,
the ServeRAID controller firmware changes the write policy to write-through until the battery unit is
sufficiently charged. When the battery unit is charged, the ServeRAID controller firmware changes the
write policy to write-back.
• For brevity, in this documentation the Intelligent Battery Backup Unit (iBBU) is often referred to as the
battery.
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Turn off the server and peripheral devices and disconnect all power cords and external devices.
Step 3. Remove the cover (see “Removing the cover” on page 195).
Step 4. Remove the cover (see “Removing the cover” on page 195).
Step 5. Push the tab to open the cover on top of the air baffle.
Release tab
Step 6. Connect one end of the cable to the ServeRAID memory module.
Step 7. Route the battery or flash power module cable along the chassis.
Attention: Make sure that the cable is not pinched and does not cover any connectors or obstruct
any components on the system board.
Step 8. Install the battery or flash power module on top of the air baffle.
a. Align the battery or flash power module cable connector with the slot on the holder. Place
the battery or flash power module into the holder and make sure that the holder engages
the battery or flash power module securely.
Note: The positioning of the battery or flash power module depends on the type of the
batteries or flash power modules that you install.
b. Connect the other end of the cable to the battery or flash power module.
00000
00000
00000
00000
00000
Note: Make sure the battery or flash power module is seated properly.
Step 10. Reinstall the cover (see “Replacing the cover” on page 196).
Step 11. Slide the server into the rack.
Step 12. Reconnect the power cords and all external cables, and turn on the server and peripheral devices.
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Turn off the server, and disconnect all power cords and external cables.
Step 3. Remove the cover (see “Removing the cover” on page 195).
Step 4. Remove the screws from the safety cover.
Step 5. Disconnect the hard disk drive backplane power cables from the connector in front of the safety
cover.
Step 6. Slide the cover forward to disengage it from the system board, and then lift it out of the server.
Step 7. If you are instructed to return the 240 VA safety cover, follow all packaging instructions, and use
any packaging materials for shipping that are supplied to you.
To remove the power paddle card cover, complete the following steps:
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Turn off the server, and disconnect all power cords and external cables.
Step 3. Remove the cover (see “Removing the cover” on page 195).
Step 4. Remove the screw from the power paddle card cover.
Safety cover
Step 5. Lift the power paddle card cover out of the server.
Step 6. If you are instructed to return the power paddle card cover, follow all packaging instructions, and
use any packaging materials for shipping that are supplied to you.
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Turn off the server and peripheral devices and disconnect the power cords and all external cables,
if necessary.
Step 3. Line up and insert the tabs on the bottom of the safety cover into the slots on the system board.
Step 4. Slide the safety cover toward the back of the server until it is secure.
Step 5. Connect the hard disk drive backplane power cables to the connector in front of the safety cover.
Step 6. Install the screws into the safety cover.
Step 7. Replacing the cover (see “Replacing the cover” on page 196).
Step 8. Slide the server into the rack.
Step 9. Reconnect the power cords and all external cables, and turn on the server and peripheral devices.
To install the power paddle card cover, complete the following steps:
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Turn off the server and peripheral devices and disconnect the power cords and all external cables,
if necessary.
Step 3. Align the power paddle card cover with the pins on the chassis and install it in the server until it
is secure.
Safety cover
Step 4. Install the screw into the power paddle card cover.
Step 5. Replacing the cover (see “Replacing the cover” on page 196).
Step 6. Slide the server into the rack.
Step 7. Reconnect the power cords and all external cables, and turn on the server and peripheral devices.
The illustrations in this document might differ slightly from your hardware.
Attention:
• To avoid damage to the hard disk drive connectors, make sure that the server cover is in place and fully
closed whenever you install or remove a hard disk drive.
• To make sure that there is adequate system cooling, do not operate the server for more than 2 minutes
without either a hard disk drive or a filler panel installed in each bay.
• Before you make changes to disk drives, disk drive controllers (including controllers that are integrated
on the system board), disk drive backplanes, or disk drive cables, back up all important data that is
stored on hard disks.
• Before you remove any component of a RAID array, back up all RAID configuration information.
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Handle
Latch
Release latch
1.8-inch
hot-swap
hard disk drive Handle
0000
0000
0000
0000
0000
000
000
000
000
Filler
b. Slide the release latch (orange) down gently to unlock the drive handle.
Step 5. Grasp the handle and slide the drive out of the drive bay.
Step 6. Reinstall the drive bay filler panel if necessary.
Step 7. If you are instructed to return the drive, follow all packaging instructions, and use any packaging
materials for shipping that are supplied to you.
Note: If you have only one drive, you must install it in bay 0.
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Remove the filler panel. Keep the filler panel in a safe place.
Step 3. Touch the static-protective package that contains the drive to any unpainted metal surface on the
server; then, remove the drive from the package and place it on a static-protective surface.
Step 4. Install a 2.5-inch hot-swap drive:
a. Make sure that the tray handle is in the open (unlocked) position.
b. Align the drive with the guide rails in the bay.
Latch
Handle
c. Gently push the drive into the bay until the drive stops.
d. Rotate the tray handle to the closed (locked) position.
Step 5. Install a 1.8-inch hot-swap drive:
1.8-inch
hot-swap
hard disk drive
0000
0000
0000
0000
0000
000
000
000
000
Filler
b. Push the drive tray into the drive bay and rotate the drive tray handle to the closed position
and ensure that the latch is in the locked position.
c. Reinstall the filler panel.
Step 6. Check the hard disk drive status LED to verify that the hard disk drive is operating correctly. If
the yellow hard disk drive status LED of a drive is lit continuously, that drive is faulty and must be
replaced. If the green hard disk drive activity LED is flashing, the drive is being accessed.
Note: If the server is configured for RAID operation using a ServeRAID adapter, you might have
to reconfigure your disk arrays after you install hard disk drives. See the ServeRAID adapter
documentation for additional information about RAID operation and complete instructions for
using the ServeRAID adapter.
Step 7. If you are installing additional hot-swap hard disk drives, do so now.
Step 8. Turn on the peripheral devices and the server.
Drive IDs
The drive ID that is assigned to each drive is printed on the front or rear of the server. The following
illustrations show the locations of the IDs of the drives. The ID numbers and the drive bay numbers are
the same.
The following illustration shows the location of the IDs of the hard disk drives. The ID numbers and the
drive bay numbers are the same.
Figure 137. Front view: 2.5-inch hot-swap hard disk drive IDs
Bay 24 Bay 25
000
00
000
0000000
000
00
000
000
000
000
0000000
000
000
000
0000000 0000000
00
000
000
000
00
00
000
00
Figure 138. Rear view: 2.5-inch hot-swap hard disk drive IDs
The following illustration shows the location of the IDs of the hard disk drives. The ID numbers and the
drive bay numbers are the same.
00000 00000
00000 00000
00000 00000
00000 00000
Figure 139. Front view: 2.5-inch and 1.8-inch hot-swap drive IDs
To remove a dual inline memory module (DIMM), complete the following steps:
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Turn off the server and peripheral devices and disconnect all power cords.
Step 3. Remove the cover (see “Removing the cover” on page 195).
Step 4. Remove the air baffle (see “Removing the air baffle” on page 199).
Step 5. Carefully open the retaining clips on each end of the DIMM connector and remove the DIMM.
Attention: To avoid breaking the retaining clips or damaging the DIMM connectors, open and
close the clips gently.
Step 6. If you are instructed to return the DIMM, follow all packaging instructions, and use any packaging
materials for shipping that are supplied to you.
Note: Values for these voltages are “specified” which means the device characteristics such as
timing are supported at this voltage. Values are “operable” which means that the devices can
be operated safely at this voltage. However, device characteristics such as timing may not
be guaranteed. All devices must be “tolerant” of the highest DDR3 nominal voltage of 1.5 V,
meaning that they may not operate at 1.5 V but may be powered at that voltage without damage
to the devices.
– wwwww is the DIMM bandwidth, in MBps
6400 = 6.40 GBps (DDR3-800 SDRAMs, 8-byte primary data bus)
8500 = 8.53 GBps (DDR3-1066 SDRAMs, 8-byte primary data bus)
10600 = 10.66 GBps (DDR3-1333 SDRAMs, 8-byte primary data bus)
12800 = 12.80 GBps (DDR3-1600 SDRAMs, 8-byte primary data bus)
14900 = 14.93 GBps (DDR3-1866 SDRAMs, 8-byte primary data bus)
– m is the DIMM type
E = Unbuffered DIMM (UDIMM) with ECC (x72-bit module data bus)
L = Load Reduction DIMM (LRDIMM)
R = Registered DIMM (RDIMM)
U = Unbuffered DIMM with no ECC (x64-bit primary data bus)
– aa is the CAS latency, in clocks at maximum operating frequency
– bb is the JEDEC SPD Revision Encoding and Additions level
– cc is the reference design file for the design of the DIMM
– d is the revision number of the reference design of the DIMM
Note: To determine the type of a DIMM, see the label on the DIMM. The information on the label is in
the format xxxxx nRxxx PC3v-xxxxxx-xx-xx-xxx. The numeral in the sixth numerical position indicates
whether the DIMM is single-rank (n=1), dual-rank (n=2), or quad-rank (n=4).
• The following rules apply to DDR3 RDIMM speed as it relates to the number of RDIMMs in a channel:
– When you install 1 RDIMM per channel, the memory runs at 1866 MHz
– When you install 2 RDIMMs per channel, the memory runs at 1600 MHz
– When you install 3 RDIMMs per channel, the memory runs at 1066 MHz
– All channels in a server run at the fastest common frequency
– Do not install registered, unbuffered, and load reduction DIMMs in the same server
• The maximum memory speed is determined by the combination of the microprocessor, DIMM speed,
DIMM type, Operating Modes in UEFI settings, and the number of DIMMs installed in each channel.
• In two-DIMM-per-channel configuration, the server automatically operates with a maximum memory
speed of up to 1600 MHz when the following condition is met:
– Two 1.35 V single-rank, dual-ranl, or quad-rank UDIMMs, RDIMMs or LRDIMMs are installed in the
same channel. In the Setup utility, Memory speed is set to Max performance and LV-DIMM power is
set to Enhance performance mode. The 1.35 V UDIMMs, RDIMMs or LRDIMMs will function at 1.5 V.
• The server supports a maximum of 16 dual-rank UDIMMs. The server supports up to two UDIMMs
per channel.
• The server supports a maximum of 24 single-rank, dual-rank, or 16 quad-rank RDIMMs. The server does
not support three quad-rank RDIMMs in the same channel.
• The UDIMM option that is available for the server is 4 GB. The server supports a minimum of 4 GB and a
maximum of 64 GB of system memory using UDIMMs.
• The RDIMM options that are available for the server are 2 GB, 4 GB, 8 GB, and 16 GB. The server
supports a minimum of 2 GB and a maximum of 384 GB of system memory using RDIMMs.
• The LRDIMM option that is available for the server is 32 GB. The server supports a minimum of 32 GB
and a maximum of 768 GB of system memory using LRDIMMs.
Note: The amount of usable memory is reduced depending on the system configuration. A certain
amount of memory must be reserved for system resources. To view the total amount of installed memory
and the amount of configured memory, run the Setup utility. For additional information, see “Configuring
the server” on page 100.
• A minimum of one DIMM must be installed for each microprocessor. For example, you must install a
minimum of two DIMMs if the server has two microprocessors installed. However, to improve system
performance, install a minimum of four DIMMs for each microprocessor.
• DIMMs in the server must be the same type (RDIMM, UDIMM, or LRDIMM) to ensure that the server
will operate correctly.
• When you install one quad-rank DIMM in a channel, install it in the DIMM connector furthest away from
the microprocessor.
1. You can install DIMMs for microprocessor 2 as soon as you install microprocessor 2; you do not have
to wait until all of the DIMM slots for microprocessor 1 are filled.
2. DIMM slots 13-24 are reserved for microprocessor 2; thus, DIMM slots 13-24 are enabled when
microprocessor 2 is installed.
The following illustration shows the location of the DIMM connectors on the system board.
Depending on the server model, the server may come with a minimum of one 2 GB or 4 GB DIMM installed
in slot 1. When you install additional DIMMs, install them in the order shown in the following table to optimize
system performance. In general, all three channels on the memory interface for each microprocessor can be
populated in any order and have no matching requirements.
If a failure occurs, the memory controller switches from the primary pair of memory DIMMs to the backup
pair of DIMMs. To enable memory mirrored channel through the Setup utility, select System Settings ➙
Memory. For more information, see “Using the Setup utility” on page 103. When you use the memory
mirrored channel feature, consider the following information:
• When you use memory mirrored channel, you must install a pair of DIMMs at a time. The two DIMMs in
each pair must be identical in size, type, and rank (single, dual, or quad), and organization, but not in
speed. The channels run at the speed of the slowest DIMM in any of the channels.
The following diagram lists the DIMM connectors on each memory channel.
The following table shows the installation sequence for memory mirrored channel mode:
You can enable rank sparing memory in the Setup utility, select System Settings ➙ Memory. For more
information, see “Using the Setup utility” on page 103.
The maximum available memory is reduced when memory rank sparing mode is enabled.
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Turn off the server and peripheral devices and disconnect the power cords and all external cables,
if necessary.
Step 3. Remove the cover (see “Removing the cover” on page 195).
Step 4. Remove PCI riser-card assemblies if necessary (see “Removing a PCI riser-card assembly” on
page 221).
Step 5. Remove the air baffle (see “Removing the air baffle” on page 199).
Attention: To avoid breaking the retaining clips or damaging the DIMM connectors, open and
close the clips gently.
Step 7. Touch the static-protective package that contains the DIMM to any unpainted metal surface on the
outside of the server. Then, remove the DIMM from the package.
Step 8. Turn the DIMM so that the alignment slot align correctly with the alignment tab.
Step 9. Insert the DIMM into the connector by aligning the edges of the DIMM with the slots at the ends of
the DIMM connector (see “System-board optional-device connectors” on page 32 for the locations
of the DIMM connectors).
Step 10. Firmly press the DIMM straight down into the connector by applying pressure on both ends of the
DIMM simultaneously. The retaining clips snap into the locked position when the DIMM is firmly
seated in the connector.
Note: If there is a gap between the DIMM and the retaining clips, the DIMM has not been correctly
inserted; open the retaining clips, remove the DIMM, and then reinsert it.
Step 11. Reconnect the power cords and any cables that you removed.
Step 12. Replace the air baffle (see “Replacing the air baffle” on page 200).
Note: Close all the retaining clips even for slots without DIMMs installed before replacing the
air baffle.
Step 13. Replace PCI riser-card assemblies if you have removed them earlier (see “Replacing a PCI
riser-card assembly” on page 222).
Step 14. Replace the cover (see “Replacing the cover” on page 196).
Step 15. Turn on the peripheral devices and the server.
Step 1. Read the safety information that begins on page “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Turn off the server and peripheral devices, and disconnect the power cord and all external cables.
Step 3. Remove the cover (see “Removing the cover” on page 195).
Step 4. Grasp the assembly at the front tab and rear edge and lift it to remove it from the server. Place the
riser-card assembly on a flat, static-protective surface.
PCI riser-card
assembly 2
000000
000000
000000
0000
000000
0000
00
0000
00
PCI riser-card
assembly 1
000
000000
000
000000
000000
000
000000
000
0
000
0000
0000
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Turn off the server and peripheral devices and disconnect all power cords.
Step 3. Remove the cover (see “Removing the cover” on page 195).
Step 4. Reinstall any adapters and reconnect any internal cables you might have removed in other
procedures (see “Replacing an adapter” on page 228 and “Internal cable routing and connectors”
on page 179).
Step 5. Align the PCI riser-card assembly with the selected PCI connector on the system board:
a. PCI connector 1: Carefully fit the two alignment slots on the side of the assembly onto the
two alignment brackets in the side of the chassis.
000000
000000
0000
000000
0000
00
0000
00
PCI riser-card
assembly 1
000
000000
000
000000
000000
000
000000
000
0
000
0000
0000
b. PCI connector 2: Carefully align the bottom edge (the contact edge) of the riser-card
assembly with the riser-card connector on the system board.
Step 6. Press down on the assembly. Make sure that the riser-card assembly is fully seated in the
riser-card connector on the system board.
Step 7. Replace the cover (see “Replacing the cover” on page 196).
Step 8. Slide the server into the rack.
Step 9. Reconnect the power cords and any cables that you removed.
Step 10. Turn on the peripheral devices and the server.
See http://www.lenovo.com/ serverproven/ for a list of hard disk drives that you can use with the server.
To remove the rear two hard-disk-drive kit, complete the following steps:
Step 1. Read the safety information that begins on page “Safety” on page v and “Installation guidelines”
on page 34.
0000000
0000000
0000000
0000000
000000
000000
000000
0000
00
0000
00
0000
0000
To install the rear two hard-disk-drive kit, complete the following steps:
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Turn off the server and peripheral devices and disconnect all power cords.
Step 3. Remove the cover (see “Removing the cover” on page 195).
Step 4. Reinstall any adapters and reconnect any internal cables you might have removed in other
procedures (see “Replacing an adapter” on page 228 and “Internal cable routing and connectors”
on page 179).
Step 5. Align the rear two hard-disk-drive kit with the connector on the system board:
0000000
0000000
0000000
0000000
000000
000000
000000
0000
00
0000
00
0000
0000
Step 6. Press down on the kit. Make sure that the kit is fully seated in the connector on the system board.
Step 7. Replace the cover (see “Replacing the cover” on page 196).
Step 8. Slide the server into the rack.
Step 9. Reconnect the power cords and any cables that you removed.
Step 10. Turn on the peripheral devices and the server.
Removing an adapter
Use this information to remove an adapter.
The following table shows the locations of the adapter expansion slots from the rear of the server.
Table 22. The maximum adapter dimension supported in each slot (rear view)
PCI riser-card assembly 1 PCI riser-card assembly 2
1 Full height, up to full length 4 Full height, up to full length
2 Full height, half length 5 Full height, up to full length
3 Full height, half length 6 Full height, half length
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Turn off the server and peripheral devices and disconnect all power cords; then, remove the
cover (see “Removing the cover” on page 195).
Step 3. Remove the PCI riser-card assembly that contains the adapter (see “Removing a PCI riser-card
assembly” on page 221).
• If you are removing an adapter from PCI expansion slot 1, 2, or 3, remove PCI riser-card
assembly 1.
• If you are removing an adapter from PCI expansion slot 4, 5, or 6, remove PCI riser-card
assembly 2.
PCI PCI
riser-card riser-card
assembly assembly
(in short position) (in long position)
Adapter Adapter
connectors connectors
000000
0000000
000000
0000000
000000
0000000
00000
000000
00000
0000000
00
00000
00000
Adapter Adapter
0000000
00000
00000
00
Full-length
adapter
bracket Full-length
adapter
bracket
Step 4. Disconnect any cables from the adapter (make note of the cable routing, in case you reinstall
the adapter later).
Step 5. Carefully grasp the adapter by its top edge or upper corners, and pull the adapter from the PCI
expansion slot.
Step 6. If the adapter is a full-length adapter in the upper expansion slot of the PCI riser-card assembly
and you do not intend to replace it with another full-length adapter, remove the full-length-adapter
bracket and store it on the underside of the top of the PCI riser-card assembly.
Step 7. If you are instructed to return the adapter, follow all packaging instructions, and use any packaging
materials for shipping that are supplied to you.
You can only install SeveRAID-H1110 adapter in the rear two hard-disk-drive kit.
Bracket
Adapter
00000000
00000000
Expansion-slot
connector 00000000
cover
00000000
0000
0000
0000
0000
Adapter
Step 4. Disconnect any cables from the adapter (make note of the cable routing, in case you reinstall
the adapter later).
Step 5. Carefully grasp the adapter by its top edge or upper corners, and pull the adapter from the rear
two hard-disk-drive kit.
Step 6. If you are instructed to return the adapter, follow all packaging instructions, and use any packaging
materials for shipping that are supplied to you.
Replacing an adapter
Use this information to replace an adapter.
Notes:
• If your adapter was previously configured, backup or record its configuration information, if possible,
before replacing the adapter. See the documentation for your adapter for information and instructions.
• If you are replacing a ServeRAID adapter, import your RAID configuration to the replacement adapter as
a foreign configuration after you finish the replacement. See the ServeRAID-M Software User Guide at
https://support.lenovo.com/us/en/documents/migr-5086126 for instructions.
• Locate the documentation that comes with the adapter and follow those instructions in addition to
the instructions in this section.
• The server provides one internal SAS/SATA RAID connector and two PCI slots on the system board.
See “System-board optional-device connectors” on page 32 for the location of the internal SAS/SATA
RAID connector and riser-card slots. You can replace the Lenovo ServeRAID SAS/SATA adapter with
an optional Lenovo ServeRAID SAS/SATA adapter in the slot. For configuration information, see the
ServeRAID documentation at http://www.lenovo.com/support.
The following table shows the locations of the adapter expansion slots from the rear of the server.
Table 23. The maximum adapter dimension supported in each slot (rear view)
PCI riser-card assembly 1 PCI riser-card assembly 2
1 Full height, up to full length 4 Full height, up to full length
2 Full height, half length 5 Full height, up to full length
3 Full height, half length 6 Full height, half length
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Turn off the server and peripheral devices and disconnect the power cords and all external cables.
Step 3. Remove the cover (see “Removing the cover” on page 195).
Step 4. Follow the cabling instructions, if any come with the adapter. Route the adapter cables before
you install the adapter.
Step 5. Stretch your PCI riser-card assembly if you are installing a full-length adapter. See “Stretching a
PCI riser-card assembly” on page 39 for instructions.
Adapter
connectors 00000000
Bracket
00000000
Expansion-slot
00000000
cover
0000
00000000
0000
0000
0000
0000
0000
0000
00
0000
0000
0000
Full-length
adapter Adapter
bracket
a. Riser-card assembly 1: if the adapter is a full-length adapter for the upper expansion slot in
the riser card, remove the full-length-adapter bracket from underneath the top of the riser-card
assembly (if any) and keep it in a safe place for potential future use.
PCI
riser-card
assembly
0000000
0000000
0000000
0000
0000000
0000
0000
00
0000
0000
0000
Full-length
adapter
bracket
b. Riser-card assembly 2: if the adapter is a full-length adapter for the upper expansion slot in
the riser card, the full-length-adapter bracket is on the cage by default.
Step 6. Align the adapter with the PCI slot on the riser card and the guide on the external end of the
riser-card assembly.
Step 7. Press the adapter firmly into the PCI slot on the riser card.
Adapter Adapter
connectors connectors
000000
0000000
000000
0000000
000000
0000000
00000
000000
00000
0000000
00
00000
00000
Adapter Adapter
0000000
00000
00000
00
Full-length
adapter
bracket Full-length
adapter
bracket
Step 8. Connect any required cables to the adapter (see “Internal cable routing and connectors” on page
179).
Attention:
• When you route cables, do not block any connectors or the ventilated space around any of
the fans.
• Make sure that cables are not routed on top of components under the PCI riser-card assembly.
• Make sure that cables are not pinched by the server components.
Step 9. Replace the PCI riser-card assembly in the server (see “Replacing a PCI riser-card assembly” on
page 222).
Step 10. Perform any configuration tasks that are required for the adapter.
Step 11. Reinstall the cover (see “Replacing the cover” on page 196).
Step 12. Slide the server into the rack.
Step 13. Reconnect the power cords and any cables that you removed.
Step 14. Turn on the peripheral devices and the server.
You can only install SeveRAID-H1110 adapter in the rear two hard-disk-drive kit.
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Turn off the server and peripheral devices and disconnect the power cords and all external cables.
Step 3. Remove the cover (see “Removing the cover” on page 195).
Step 4. Remove the rear two hard-disk-drive kit (see “Removing the rear two hard-disk-drive kit” on
page 224).
Step 5. Follow the cabling instructions, if any come with the adapter. Route the adapter cables before
you install the adapter.
Bracket
Adapter
00000000
00000000
Expansion-slot
connector 00000000
cover
00000000
0000
0000
0000
0000
Adapter
Step 8. Connect any required cables to the adapter (see “Internal cable routing and connectors” on page
179).
Attention:
• When you route cables, do not block any connectors or the ventilated space around any of
the fans.
• Make sure that cables are not routed on top of components under the rear two hard-disk-drive
kit.
• Make sure that cables are not pinched by the server components.
Step 9. Replace the rear two hard-disk-drive kit in the server (see “Replacing the rear two hard-disk-drive
kit” on page 225).
Step 10. Perform any configuration tasks that are required for the adapter.
Step 11. Reinstall the cover (see “Replacing the cover” on page 196).
Step 12. Slide the server into the rack.
Step 13. Reconnect the power cords and any cables that you removed.
Step 14. Turn on the peripheral devices and the server.
To remove the ServeRAID adapter memory module, complete the following steps:
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Turn off the server and peripheral devices and disconnect all power cords.
Step 3. Remove the cover (see “Removing the cover” on page 195).
Step 4. Disconnect the cable from the flash power module.
00000
00000
00000
00000
00000
Step 5. Remove the ServeRAID adapter memory module from the system board.
Connector
Rentention pins
Step 6. Disconnect the cable from the ServeRAID adapter memory module.
If you are instructed to return the memory module, follow all packaging instructions, and use any packaging
materials for shipping that are supplied to you.
To install the ServeRAID adapter memory module, complete the following steps:
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Turn off the server and peripheral devices and disconnect all power cords.
Step 3. Remove the cover (see “Removing the cover” on page 195).
Step 4. Connect the cable to the ServeRAID adapter memory module.
Step 5. Align the memory module with the retention pins. Install the ServeRAID adapter memory module
into the system board.
Connector
Rentention pins
Step 6. Connect the other end of the cable to the flash power module.
00000
00000
00000
00000
00000
Note: Make sure the flash power module is seated properly (see “Replacing a RAID adapter
battery or flash power module” on page 203).
Step 7. Reconnect the power cords and any cables that you removed.
Step 8. Reinstall the cover (see “Replacing the cover” on page 196).
Step 9. Slide the server into the rack.
Step 10. Turn on the peripheral devices and the server.
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Turn off the server and peripheral devices and disconnect the power cords and all external cables,
if necessary.
Step 3. Remove the cover (see “Removing the cover” on page 195).
Step 4. Remove PCI riser-card assembly 2, if any (see “Removing a PCI riser-card assembly” on page 221).
Step 5. Loosen the two captive screws on the network adapter from the screw holes on the system board.
Captive screws
Retention
brackets
00
00
00
00
00
000
000
000
00
000
Thumbscrew
000
Pin
Screw holes
Retention
brackets
00
00
00
00
00
000
000
000
00
000
Thumbscrew
000
Pin
Network
adapter connector
Step 8. If you are instructed to return the adapter, follow all packaging instructions, and use any packaging
materials for shipping that are supplied to you.
To order a dual-port network adapter option, contact your Lenovo sales representative or Lenovo reseller.
The following notes describe the types of adapters that the server supports and other information that
you must consider when you install an adapter:
• To configure network adapters, complete the following steps:
1. From the Setup utility main menu (see “Using the Setup utility” on page 103), select System Settings
➙ Network.
2. From the Network Device List, select one network adapter.
Note: You might need to enter each item (displaying MAC address) to see detailed information.
3. Press Enter to configure the network adapter settings.
• To convert the NIC/iSCSI/FCoE for Emulex Dual Port 10GbE SFP+ Embedded VFA III, complete the
following steps:
Note: You might need to enter each item (displaying MAC address) to see detailed information.
3. Press Enter to configure Emulex network adapter, select Personality and press Enter to change
the settings.
– NIC
– iSCSI (enabled after FoD installed)
– FCoE (enabled after FoD installed)
• To download the latest version of drivers for iSCSI and FCoE from the Lenovo website, complete the
following steps:
1. Go to http://www.ibm.com/support/ fixcentral.
2. Click Product support ➙ System x ➙ Product family ➙ System x3650 M4 HD ➙ 5460.
3. From the Operating system menu, select your operating system, and then click Search to display
the available drivers.
4. Download the latest version of drivers.
– Emulex iSCSI Device Driver for Windows 2008
– Emulex FCoE Device Driver for Windows 2008
Note: Changes are made periodically to the Lenovo website. The actual procedure might vary slightly
from what is described in this document.
• Port 0 on the Emulex Dual Port 10GbE SFP+ Embedded VFA III can be configured as shared system
management.
• When the server is in standby mode, both ports on the Emulex Dual Port 10GbE SFP+ Embedded VFA
III function at 100M connection speed with Wake on LAN feature.
The Emulex Dual Port 10GbE SFP+ Embedded VFA III is automatically disabled if one of the following
errors occurs:
• An error log indicates a temperature warning for the Ethernet adapter.
• All power supplies are removed or the server is disconnected from the power source.
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Turn off the server and peripheral devices and disconnect the power cords and all external cables,
if necessary.
Step 3. Remove the cover (see “Removing the cover” on page 195).
Step 4. Remove PCI riser-card assembly 2, if any (see “Removing a PCI riser-card assembly” on page 221).
Step 5. Loosen the thumbscrew to remove the network adapter filler panel on the rear of the chassis (if
it has not been removed already).
00
00
00
00
00
000
000
000
00
000
000
Step 6. Touch the static-protective package that contains the new adapter to any unpainted metal surface
on the server. Then, remove the adapter from the package.
Step 7. Align the adapter so that the port connectors on the adapter line up with the pin and thumbscrew
on the chassis; then, align the connector of the adapter with the adapter connector on the system
board.
Screw holes
Retention
brackets
00
00
00
00
00
000
000
000
00
000
Thumbscrew
000
Pin
Network
adapter connector
Step 8. Press the adapter firmly until the pin, and retention brackets engage the adapter. Make sure the
adapter is securely seated on the connector on the system board.
Attention: Make sure the port connectors on the adapter are aligned properly with the chassis on
the rear of the server. An incorrectly seated adapter might cause damage to the system board
or the adapter.
Step 9. Fasten the thumbscrew on the rear side of the chassis.
Retention
brackets
00
00
00
00
00
000
000
000
00
000
Thumbscrew
000
Pin
Step 10. Fasten the two captive screws on the network adapter.
Step 11. Reinstall PCI riser-card assembly 2 in PCI riser connector 2 if you have removed it previously (see
“Replacing a PCI riser-card assembly” on page 222).
Step 12. Replace the cover (see “Replacing the cover” on page 196).
Step 13. Slide the server into the rack.
Step 14. Reconnect the power cords and any cables that you removed.
Step 15. Turn on the peripheral devices and the server.
Attention: To ensure proper server operation, replace a failed hot-swap fan within 30 seconds.
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Remove the cover (see “Removing the cover” on page 195). The LED on the system board near the
connector for the failing hot-swap fan will be lit.
Attention: To ensure proper system cooling, do not remove the top cover for more than 30 minutes
during this procedure.
Step 3. Grasp the hot-swap fan by the finger grips on the sides of the dual-motor hot-swap fan.
Fan 4
Fan 3
Fan 2
Fan 1
Attention: To ensure proper operation, replace a failed hot-swap fan within 30 seconds.
Step 6. If you are instructed to return the fan, follow all of the packaging instructions, and use any
packaging materials for shipping that are supplied to you.
For proper cooling, the server requires that all four hot-swap fans be installed at all times.
Attention: To ensure proper operation, replace a failed hot-swap fan within 30 seconds.
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Remove the cover (see “Removing the cover” on page 195).
Step 3. Rotate the air baffle up.
Step 4. Touch the static-protective package that contains the new fan to any unpainted metal surface on
the server. Then, remove the new fan from the package.
Step 5. Orient the fan over the fan slot in the fan assembly bracket so that the fan connector aligns with
the connector on the system board.
Step 6. Insert the fan into the fan slot in the fan assembly bracket and press it down until it is seated
correctly in the slot and the fan connector is seated correctly in the connector on the system board.
Fan 4
Fan 3
Fan 2
Fan 1
Note: Make sure that the newly-installed fan aligns horizontally with other correctly-seated fans
for proper installation.
Step 7. Replace the cover (see “Replacing the cover” on page 196).
Step 8. Slide the server into the rack.
Note: To remove or install a fan, it is not necessary to remove the fan bracket. See “Removing a hot-swap
fan” on page 241 and “Replacing a hot-swap fan” on page 242.
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Turn off the server and peripheral devices and disconnect the power cords and all external cables.
Step 3. Remove the cover (see “Removing the cover” on page 195).
Step 4. Remove the fans (see “Removing a hot-swap fan” on page 241).
Step 5. Remove the fan bracket.
a. If there are screws installed in the fan bracket, remove the three screws.
b. Press the fan-bracket release latches toward each other and lift the fan bracket out of the
server.
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Turn off the server and peripheral devices and disconnect all power cords.
Step 3. Remove the cover (see “Removing the cover” on page 195).
Step 4. Lower the fan bracket into the chassis.
Pins
Step 5. Align the holes in the bottom of the bracket with the pins in the bottom of the chassis.
Step 6. Press the bracket into position until the fan-bracket release levers click into place.
Step 7. Install the three screws in the fan bracket if present.
Step 8. Replace the fans (see “Replacing a hot-swap fan” on page 242).
Step 9. Replace the cover (see “Replacing the cover” on page 196).
Step 10. Slide the server into the rack.
Step 11. Reconnect the power cords and any cables that you removed.
Step 12. Turn on the peripheral devices and the server.
Statement 5
CAUTION:
The power control button on the device and the power switch on the power supply do not turn off
the electrical current supplied to the device. The device also might have more than one power
cord. To remove all electrical current from the device, ensure that all power cords are disconnected
from the power source.
CAUTION:
Never remove the cover on a power supply or any part that has the following label attached.
Hazardous voltage, current, and energy levels are present inside any component that has this label
attached. There are no serviceable parts inside these components. If you suspect a problem with
one of these parts, contact a service technician.
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. If only one power supply is installed, turn off the server and peripheral devices and disconnect
all power cords.
Step 3. If the server is in a rack, at the back of the server, pull back the cable management arm to gain
access to the rear of the server and the power supply.
Step 4. Press and hold the release tab to the left. Grasp the handle and pull the power supply out of
the server.
0000000
0000
0000000
0000000
0000000
0000
0000
0000
0000000
0000
0000
0000
0000000
0000
0000000
0000000
0000
0000
0000
0000
00
0000
Power supply
000
filler panel
000
Hot-swap
power supply 2
Step 5. If you are instructed to return the power supply, follow all packaging instructions, and use any
packaging materials for shipping that are supplied to you.
Statement 29
CAUTION: This equipment is designed to permit the connection of the earthed conductor of the dc supply
circuit to the earthing conductor at the equipment.
This equipment is designed to permit the connection of the earthed conductor of the dc supply circuit to the
earthing conductor at the equipment. If this connection is made, all of the following conditions must be met:
• This equipment shall be connected directly to the dc supply system earthing electrode conductor or to a
bonding jumper from an earthing terminal bar or bus to which the dc supply system earthing electrode
conductor is connected.
• This equipment shall be located in the same immediate area (such as, adjacent cabinets) as any other
equipment that has a connection between the earthed conductor of the same dc supply circuit and the
earthing conductor, and also the point of earthing of the dc system. The dc system shall not be earthed
elsewhere.
• The dc supply source shall be located within the same premises as this equipment.
• Switching or disconnecting devices shall not be in the earthed circuit conductor between the dc source
and the point of connection of the earthing electrode conductor.
Statement 31
To Connect: To Disconnect:
1. Turn OFF all power sources and equipment that is to 1. Turn OFF all power sources and equipment that is to
be attached to this product. be attached to this product.
2. Attach signal cables to the product. • For ac systems, remove all power cords from the
3. Attach power cords to the product. chassis power receptacles or interrupt power at
the ac power distribution unit.
• For ac systems, use appliance inlets.
• For dc systems, disconnect dc power sources
• For dc systems, ensure correct polarity of -48 V dc at the breaker panel or by turning off the power
connections: RTN is + and -48 V dc is -. Earth source. Then, remove the dc cables.
ground should use a two-hole lug for safety.
2. Remove the signal cables from the connectors.
4. Attach signal cables to other devices.
3. Remove all cables from the devices.
5. Connect power cords to their sources.
6. Turn ON all the power sources.
Statement 33
CAUTION:
This product does not provide a power-control button. Turning off blades or removing power modules
and I/O modules does not turn off electrical current to the product. The product also might have more
than one power cord. To remove all electrical current from the product, make sure that all power
cords are disconnected from the power source.
Statement 34
Important: Be sure to read the multilingual safety instructions on the CD that comes with the server
before you use the product.
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. If only one power supply is installed, turn off the server and peripheral devices and disconnect
all power cords.
Step 3. If the server is in a rack, at the back of the server, pull back the cable management arm to gain
access to the rear of the server and the power supply.
Step 4. Press and hold the release tab to the left. Grasp the handle and pull the power supply out of
the server.
0000000
0000
0000000
0000000
0000000
0000
0000
0000
0000000
0000
0000
0000
0000000
0000
0000000
0000000
0000
0000
0000
0000
00
0000
Power supply
000
filler panel
000
Hot-swap
power supply 2
Step 5. If you are instructed to return the power supply, follow all packaging instructions, and use any
packaging materials for shipping that are supplied to you.
The following notes describe the type of power supply that the server supports and other information that
you must consider when you install a power supply:
• Before you install an additional power supply or replace a power supply with one of a different wattage,
you may use the Power Configurator utility to determine current system power consumption. For more
information and to download the utility, go to http://www.ibm.com/systems/ bladecenter/resources/
powerconfig.html.
• The server comes with one hot-swap 12-volt output power supply that connects to power supply bay 1.
The input voltage is 100-127 V ac or 200-240 V ac auto-sensing.
• Power supplies in the server must be with the same power rating or wattage to ensure that the server will
operate correctly. For example, you cannot mix 550-watt and 750-watt power supplies in the server.
• Power supply 1 is the default/primary power supply. If power supply 1 fails, you must replace the power
supply with the same wattage immediately.
• You can order an optional power supply for redundancy.
• These power supplies are designed for parallel operation. In the event of a power-supply failure, the
redundant power supply continues to power the system. The server supports a maximum of two
power supplies.
Statement 5
2
1
Statement 8
CAUTION:
Never remove the cover on a power supply or any part that has the following label attached.
Hazardous voltage, current, and energy levels are present inside any component that has this label
attached. There are no serviceable parts inside these components. If you suspect a problem with
one of these parts, contact a service technician.
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Touch the static-protective package that contains the hot-swap power supply to any unpainted
metal surface on the server; then, remove the power supply from the package and place it on
a static-protective surface.
Step 3. If you are installing a hot-swap power supply into an empty bay, remove the power-supply filler
from the power-supply bay.
0000000
0000
0000000
0000000
0000000
0000
0000
0000
0000000
0000
0000
0000
0000000
0000
0000000
0000000
0000
0000
0000
0000
00
0000
Power supply
000
filler panel
000
Hot-swap
power supply 2
Step 4. Grasp the handle on the rear of the power supply and slide the power supply forward into the
power-supply bay until it clicks. Make sure that the power supply connects firmly into the
power-supply connector.
Attention: Do not install the different power rating or wattage of power supplies, high-efficiency
and non-high-efficiency power supplies in the server.
Step 5. Route the power cord through the clip next to power-supply and through any cable clamps on
the rear of the server, to prevent the power cord from being accidentally pulled out when you
slide the server in and out of the rack.
Step 6. Connect the power cord for the new power supply to the power-cord connector on the power
supply. The following illustration shows the power-cord connectors on the rear of the server.
0000000 0000000
00
000
000
0000000 0000000
00
000
000
0000000 0000000
000
000
000
0000000 0000000
000
0000000 0000000
000
000
000
0000000 0000000
000
000
00
000
00
00
000
0000
Power cord
connectors
Step 7. Connect the other end of the power cord to a properly grounded electrical outlet.
Step 8. Make sure that the ac power LED and the dc power LED on the ac power supply are lit, indicating
that the power supply is operating correctly. The two green LEDs are to the right of the power-cord
connector.
Step 9. If you are replacing a power supply with one of a different wattage in the server, apply the new
power information label provided over the existing power information label on the server. Power
supplies in the server must be with the same power rating or wattage to ensure that the server
will operate correctly.
Step 10. If you are adding a power supply to the server, attach the redundant power information label that
comes with this power supply on the server cover near the power supplies.
XXXW ~ AC XXXW ~ AC
1 xxx-xxx/ 2 xxx-xxx/
xxx-xxxV~ xxx-xxxV~
x,x/x,x A x,x/x,x A
xx/xx Hz xx/xx Hz
0000
00000
0000
00000
00000
0000
00000
0000
00000
0000
00
00000
000
00
00000
000
000
Power supplies
The following notes describe the type of power supply that the server supports and other information that
you must consider when you install a power supply:
• Before you install an additional power supply or replace a power supply with one of a different wattage,
you may use the Power Configurator utility to determine current system power consumption. For more
information and to download the utility, go to http://www.ibm.com/systems/ bladecenter/resources/
powerconfig.html.
• The server comes with one hot-swap 12-volt output power supply that connects to power supply bay 1.
The input voltage is -48 V dc or -60 V dc auto-sensing.
• Before you install a dc power supply in the server, you must remove all ac power supplies. Do not use
both ac and dc power supplies in the same server. Install up to two dc power supplies or up to two ac
power supplies, but not a combination.
Regulations
• It is the customer's responsibility to supply the necessary power cable.
To reduce the risk of electric shock or energy hazards:
– Use a circuit breaker that is rated at 25 amps.
– Use 2.5 mm2 (12 AWG) at 90°C copper wire.
– Torque the wiring-terminal screws to 0.50 ~ 0.60 newton-meters (4.43 ~ 5.31 inch-pounds).
For more information, see “Statement 34” on page 258.
• If the power source requires ring terminals, you must use a crimping tool to install the ring terminals to
the power cord wires. The ring terminals must be UL approved and must accommodate the wire that is
described in the above-mentioned note .
Statement 29
CAUTION:
This equipment is designed to permit the connection of the earthed conductor of the dc supply
circuit to the earthing conductor at the equipment.
This equipment is designed to permit the connection of the earthed conductor of the dc supply circuit to the
earthing conductor at the equipment. If this connection is made, all of the following conditions must be met:
• This equipment shall be connected directly to the dc supply system earthing electrode conductor or to a
bonding jumper from an earthing terminal bar or bus to which the dc supply system earthing electrode
conductor is connected.
• This equipment shall be located in the same immediate area (such as, adjacent cabinets) as any other
equipment that has a connection between the earthed conductor of the same dc supply circuit and the
earthing conductor, and also the point of earthing of the dc system. The dc system shall not be earthed
elsewhere.
• The dc supply source shall be located within the same premises as this equipment.
• Switching or disconnecting devices shall not be in the earthed circuit conductor between the dc source
and the point of connection of the earthing electrode conductor.
Statement 31
To Connect: To Disconnect:
1. Turn OFF all power sources and equipment that is to 1. Turn OFF all power sources and equipment that is to
be attached to this product. be attached to this product.
2. Attach signal cables to the product. • For ac systems, remove all power cords from the
3. Attach power cords to the product. chassis power receptacles or interrupt power at
the ac power distribution unit.
• For ac systems, use appliance inlets.
• For dc systems, disconnect dc power sources
• For dc systems, ensure correct polarity of -48 V dc at the breaker panel or by turning off the power
connections: RTN is + and -48 V dc is -. Earth source. Then, remove the dc cables.
ground should use a two-hole lug for safety.
2. Remove the signal cables from the connectors.
4. Attach signal cables to other devices.
3. Remove all cables from the devices.
5. Connect power cords to their sources.
6. Turn ON all the power sources.
Statement 33
CAUTION:
This product does not provide a power-control button. Turning off blades or removing power modules
and I/O modules does not turn off electrical current to the product. The product also might have more
than one power cord. To remove all electrical current from the product, make sure that all power
cords are disconnected from the power source.
CAUTION:
To reduce the risk of electric shock or energy hazards:
• This equipment must be installed by trained service personnel in a restricted-access location,
as defined by the NEC and IEC 60950-1, First Edition, The Standard for Safety of Information
Technology Equipment.
• Connect the equipment to a properly grounded safety extra low voltage (SELV) source. A SELV
source is a secondary circuit that is designed so that normal and single fault conditions do not
cause the voltages to exceed a safe level (60 V direct current).
• Incorporate a readily available approved and rated disconnect device in the field wiring.
• See the specifications in the product documentation for the required circuit-breaker rating for
branch circuit overcurrent protection.
• Use copper wire conductors only. See the specifications in the product documentation for the
required wire size.
• See the specifications in the product documentation for the required torque values for the
wiring-terminal screws.
Important: Be sure to read the multilingual safety instructions on the CD that comes with the server
before you use the product.
Attention: Only trained service personnel other than Lenovo service technicians are authorized to install
and remove the -48 volt dc power supply, and make the connections to and disconnections from the -48
volt dc power source. Lenovo service technicians are not certified or authorized to install or remove the
-48 volt power cable. The customer is responsible for ensuring that only trained service personnel install or
remove the -48 volt power cable.
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Touch the static-protective package that contains the hot-swap power supply to any unpainted
metal surface on the server; then, remove the power supply from the package and place it on
a static-protective surface.
Step 5. If you are installing a hot-swap power supply into an empty bay, remove the power-supply filler
from the power-supply bay.
0000
0000000
0000
0000000
0000000
0000000
0000
0000
0000
0000000
0000
0000
0000
0000000
0000
0000000
0000000
0000
0000
0000
0000
00
0000
Power supply
000
filler panel
000
Hot-swap
power supply 2
Step 6. Grasp the handle on the rear of the power supply and slide the power supply forward into the
power-supply bay until it clicks. Make sure that the power supply connects firmly into the
power-supply connector.
Step 7. Route the power cord through the handle and cable tie if any, so that it does not accidentally
become unplugged.
Step 8. Connect the other ends of the dc power cable to the dc power source. Cut the wires to the
correct length, but do not cut them shorter than 150 mm (6 inch). If the power source requires
ring terminals, you must use a crimping tool to install the ring terminals to the power cord wires.
The ring terminals must be UL approved and must accommodate the wires that are described in
“Regulations” on page 256. The minimum nominal thread diameter of a pillar or stud type of
terminal must be 4 mm; for a screw type of terminal the diameter must be 5.0 mm.
Step 12. If you are adding a power supply to the server, attach the redundant power information label that
comes with this power supply on the server cover near the power supplies.
Attention:
1. Before removing any components or disconnecting any cables, keep note of their respective locations
and how they are connected to the system board.
To remove the hot-swap hard disk drive backplane, complete the following steps:
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Turn off the server and peripheral devices and disconnect the power cords and all external cables,
if necessary.
Step 3. Remove the cover (see “Removing the cover” on page 195).
Retention latch
Backplane
Step 7. Disconnect all cables from the hard disk drive backplane.
If you are instructed to return the hard disk drive backplane, follow all packaging instructions, and use any
packaging materials for shipping that are supplied to you.
Attention:
1. Before removing any components or disconnecting any cables, keep note of their respective locations
and how they are connected to the system board.
To replace the hot-swap hard disk drive backplane, complete the following steps:
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Remove the cover (see “Removing the cover” on page 195).
Step 3. Align the backplane with the backplane slot in the chassis and the small slots on top of the hard
disk drive cage.
Step 4. Lower the backplane into the slots on the chassis.
Step 5. Rotate the top of the backplane until the front tab clicks into place into the latches on the chassis.
Backplane
Attention:
1. Before removing any components or disconnecting any cables, keep note of their respective locations
and how they are connected to the system board.
To remove the 8x1.8-inch hot-swap SSD backplane assembly, complete the following steps:
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Turn off the server and peripheral devices and disconnect the power cords and all external cables,
if necessary.
Step 3. If the server is installed in a rack, slide it out of the rack.
Step 4. Remove the cover (see “Removing the cover” on page 195).
Step 5. Remove the drive filler panel.
8x1.8-inch
drive backplane 0000
assembly 0000
0000
0000
0000
0000
0000
0000
0000
Release latch
1.8-inch
filler panel
If you are instructed to return the drive backplane, follow all packaging instructions, and use any packaging
materials for shipping that are supplied to you.
Attention:
1. Before removing any components or disconnecting any cables, keep note of their respective locations
and how they are connected to the system board.
To replace the 8x1.8-inch hot-swap SSD backplane assembly, complete the following steps:
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Turn off the server and peripheral devices and disconnect the power cords and all external cables,
if necessary.
Step 3. Remove the cover (see “Removing the cover” on page 195).
Step 4. Align the drive backplane assembly with the drive-bay slots in which you want to install the
assembly.
assembly 0000
0000
0000
0000
0000
0000
0000
0000
1.8-inch
filler panel
Step 5. Slide the drive backplane assembly into the slot until it clicks into place.
Step 6. Connect the combination power/configuration cable to the connectors on the backplane assembly;
then connect the signal cables to the backplane assembly (as shown in the illustration).
Note: You can reconnect the cables to the drive backplane before installing the backplane onto the
cage or you can connect the cables after you install the backplane, if that is easier for you.
Step 7. Reinstall the drives that you removed from the old assembly into the new drive backplane assembly
(see “Replacing a hot-swap drive” on page 211).
Step 8. Install the drive filler panel.
Step 9. Install the cover (see “Replacing the cover” on page 196).
Step 10. Slide the server into the rack.
Step 11. Reconnect the power cords and any cables that you removed.
Step 12. Turn on the peripheral devices and the server.
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Turn off the server and peripheral devices and disconnect the power cords.
Step 3. Remove the cover (see “Removing the cover” on page 195).
Step 4. Remove the flash device:
USB embedded
hypervisor
flash device
00
00
00
00
00
000
000
000
00
000
000
a. Unlock the retention latch on the USB connector by pushing down on the blue lockbar.
b. Grasp the flash device and pull to remove it from the connector.
If you are instructed to return the flash device, follow all packaging instructions, and use any packaging
materials for shipping that are supplied to you.
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Turn off the server and peripheral devices and disconnect the power cords.
Step 3. Remove the cover (see “Removing the cover” on page 195).
Step 4. Remove PCI riser-card assembly 2 (see “Removing a PCI riser-card assembly” on page 221).
Step 5. Install the flash device:
USB embedded
hypervisor
flash device
00
00
00
00
00
000
000
000
00
000
000
a. Align the flash device with the connector on the system board and push it into the USB
connector until it is firmly seated.
b. Slightly pull up on the blue lockbar to lock the flash device into the USB connector.
Step 6. Reconnect the power cords and any cables that you removed.
Step 7. Replace the cover (see “Replacing the cover” on page 196).
Step 8. Slide the server into the rack.
Step 9. Turn on the peripheral devices and the server.
• Lenovo has designed this product with your safety in mind. The lithium battery must be handled correctly
to avoid possible danger. If you replace the battery, you must adhere to the following instructions.
Note: In the U. S., call 1-800-IBM-4333 for information about battery disposal.
• If you replace the original lithium battery with a heavy-metal battery or a battery with heavy-metal
components, be aware of the following environmental consideration. Batteries and accumulators that
contain heavy metals must not be disposed of with normal domestic waste. They will be taken back
free of charge by the manufacturer, distributor, or representative, to be recycled or disposed of in a
proper manner.
• To order replacement batteries, call 1-800-IBM-SERV within the United States, and 1-800-465-7999 or
1-800-465-6666 within Canada. Outside the U.S. and Canada, call your Lenovo sales representative or
Lenovo reseller.
CAUTION:
When replacing the lithium battery, use only Lenovo Part Number 33F8354 or an equivalent type
battery recommended by the manufacturer. If your system has a module containing a lithium
battery, replace it only with the same module type made by the same manufacturer. The battery
contains lithium and can explode if not properly used, handled, or disposed of.
Do not:
– Throw or immerse into water
– Heat to more than 100°C (212°F)
– Repair or disassemble
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Turn off the server and peripheral devices and disconnect the power cords and all external cables,
if necessary.
Step 3. Remove the cover (see “Removing the cover” on page 195).
Step 4. If necessary, lift the PCI riser-card assembly 2 out of the way (see “Removing a PCI riser-card
assembly” on page 221).
Step 5. Remove the system battery:
a. If there is a rubber cover on the battery holder, use your fingers to lift the battery cover from
the battery connector.
b. Use one finger to tilt the battery horizontally out of its socket, pushing it away from the socket.
Attention: Neither tilt nor push the battery by using excessive force.
c. Use your thumb and index finger to lift the battery from the socket.
Attention: Do not lift the battery by using excessive force. Failing to remove the battery
properly may damage the socket on the system board. Any damage to the socket may require
replacing the system board.
Step 6. Dispose of the battery as required by local ordinances or regulations. See the Lenovo Environmental
Notices and User's Guide on the Lenovo Documentation CD for more information.
• When replacing the system battery, you must replace it with a lithium battery of the same type from
the same manufacturer.
• To order replacement batteries, call 1-800-426-7378 within the United States, and 1-800-465-7999 or
1-800-465-6666 within Canada. Outside the U.S. and Canada, call your Lenovo sales representative or
Lenovo reseller.
• After you replace the system-board battery, you must reconfigure the server and reset the system date
and time.
• To avoid possible danger, read and follow the following safety statement.
Statement 2
CAUTION:
When replacing the lithium battery, use only Lenovo Part Number 33F8354 or an equivalent type
battery recommended by the manufacturer. If your system has a module containing a lithium battery,
replace it only with the same module type made by the same manufacturer. The battery contains
lithium and can explode if not properly used, handled, or disposed of.
Do not:
• Throw or immerse into water
• Heat to more than 100°C (212°F)
• Repair or disassemble
Step 1. Follow any special handling and installation instructions that come with the replacement battery.
Step 2. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 3. Turn off the server and peripheral devices and disconnect the power cords and all external cables,
if necessary.
Step 4. Remove the cover (see “Removing the cover” on page 195).
Step 5. If necessary, lift the PCI riser-card assembly 2 out of the way (see “Removing a PCI riser-card
assembly” on page 221).
Step 6. Insert the new battery:
a. Tilt the battery so that you can insert it into the socket on the side opposite the battery clip.
b. Press the battery down into the socket until it clicks into place. Make sure that the battery clip
holds the battery securely.
c. If you removed a rubber cover from the battery holder, use your fingers to install the battery
cover on top of the battery connector.
Step 7. Reinstall the PCI riser-card assembly 2 (see “Replacing a PCI riser-card assembly” on page 222), if
necessary.
Step 8. Install the cover (see “Replacing the cover” on page 196).
Step 9. Slide the server into the rack.
Step 10. Reconnect the external cables; then, reconnect the power cords and turn on the peripheral devices
and the server.
Step 11. Start the Setup utility and reset the configuration.
To remove the front video and USB breakout cable, complete the following steps:
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Disconnect the cables connected to the front video and USB connectors.
Step 3. Loosen the two captive screws on the breakout cable.
USB port
Video connector
If you are instructed to return the breakout cable, follow all packaging instructions, and use any packaging
materials for shipping that are supplied to you.
To install the front video and USB breakout cable, complete the following steps:
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Insert the video and USB breakout cable on the breakout connector from the front of the server.
USB port
Video connector
To remove the video and USB breakout signal cable, complete the following steps:
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Turn off the server and peripheral devices and disconnect the power cords and all external cables,
if necessary.
Step 3. Remove the front video and USB breakout cable (see “Removing the front video and USB breakout
cable” on page 271).
Note: Use the hex screw driver to remove the two screws.
KVM connector
assembly
Step 7. Disconnect the front video and USB breakout signal cable from the system board.
00000000
0000000
00000000
0000000
Figure 195. Disconnecting the video and USB breakout signal cable from system board
Step 8. Remove the SAS, power and operator information panel cables from the cable clips and move
them aside. The power cable is present when the third backplane is installed in the server.
Cable clip
Figure 196. SAS, power and operator information panel cable removal
Step 9. Remove the video and USB breakout signal cable from the cable clip; then, slide the cable out
from the chassis.
2
Cable clip
Step 10. If you are instructed to return the breakout cable, follow all packaging instructions, and use any
packaging materials for shipping that are supplied to you.
To install the video and USB breakout signal cable, complete the following steps:
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Connect the video and USB breakout signal cable to the system board.
00000000
0000000
00000000
0000000
Figure 198. Connecting the video and USB breakout signal cable to the system board
Step 3. Route the video and USB breakout signal cable along the chassis. Make sure it passes through the
relevant cable clips.
Cable clip 1
Step 4. Reconnect the video and USB breakout signal cable to the KVM assembly; then, install the two
screws to secure the KVM assembly to the side of the chassis.
Note: Use the hex screw driver to install the two screws.
KVM connector
assembly
Step 5. Insert the SAS, power and operator information panel cables into the cable clips. The power cable
is present when the third backplane is installed in the server.
Figure 201. SAS, power and operator information panel cable insertion
Step 6. Install the bezel (see “Replacing the bezel” on page 198).
Step 7. Install the cover (see “Replacing the cover” on page 196).
Step 8. Insert the video and USB breakout cable (see “Replacing the front video and USB breakout
cable” on page 272).
Step 9. Slide the server into the rack.
Step 10. Reconnect the power cords and any cables that you removed.
Step 11. Turn on the peripheral devices and the server.
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Turn off the server and peripheral devices and disconnect the power cords and all external cables,
if necessary.
Step 3. Remove the cover (see “Removing the cover” on page 195).
Step 4. Disconnect the cable from the back of the operator information panel assembly.
Operator information
panel cable
Step 5. Remove the bezel (see “Removing the bezel” on page 197).
Step 6. Rotate the bezel to loosen the two screws from the bezel.
Note: Use the hex screw driver to remove the two screws.
Screws
Operator information
panel assembly Hex screw driver
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Note: Use the hex screw driver to install the two screws.
Screws
Operator information
panel assembly Hex screw driver
Step 6. Replace the bezel (see “Replacing the bezel” on page 198).
Step 7. Connect the operator information cable from the system board to the rear of the assembly (see
“Cabling operator information panel” on page 180).
Operator information
panel assembly
Operator information
panel cable
Step 8. Replace the cover (see “Replacing the cover” on page 196).
Step 9. Slide the server into the rack.
Step 10. Reconnect the power cords and any cables that you removed.
Step 11. Turn on the peripheral devices and the server.
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Turn off the server and peripheral devices and disconnect the power cords and all external cables,
if necessary.
Step 3. Pull power supply 2 slightly out of the rear of the server, just enough to disengage it from the server.
Step 4. Remove the cover (see “Removing the cover” on page 195).
Step 5. Remove the power paddle card cover (see “Removing the power paddle card cover” on page 207).
Step 6. Remove the two screws from the power paddle card and lift it out of the server.
Screws
If you are instructed to return the power paddle card, follow all packaging instructions, and use any
packaging materials for shipping that are supplied to you.
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Turn off the server and peripheral devices and disconnect the power cords and all external cables,
if necessary.
Step 3. Install the power paddle card in the server.
The illustrations in this document might differ slightly from your hardware.
Important: Always use the microprocessor installation tool to remove a microprocessor. Failing to use
the microprocessor installation tool may damage the microprocessor sockets on the system board. Any
damage to the microprocessor sockets may require replacing the system board.
• Be extremely careful, the microprocessor socket contacts are very fragile. Do not touch the
microprocessor socket contacts. Contaminants on the microprocessor contacts or microprocessor socket
contacts, such as oil from your skin, can cause connection failures between the contacts and the socket.
• Do not allow the thermal grease on the microprocessor and heat sink to come in contact with anything.
Contact with any surface can contaminate the thermal grease and the microprocessor socket.
• Do not use any tools or sharp objects to lift the locking levers on the microprocessor socket. Doing so
might result in permanent damage to the system board.
Note: Be sure to use the installation tool that comes with your microprocessor installation tool assembly.
The tools are similar in function and design, however Tool A has one setting for installing one size of
microprocessor, and supports the following families of microprocessors: E5-26xx, E5-46xx. Installation Tool
B has two settings for installing two different sizes of microprocessors. The settings that are marked on Tool
B are “L” for smaller low core microprocessors, and “H” for larger high core microprocessors. Installation
Tool B supports the following families of microprocessors: E5-26xx, E5-46xx, E5-26xx v2, E5-46xx v2.
Installation tool
Installation tool
Microprocessor
Cover
Microprocessor
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Turn off the server and peripheral devices and disconnect all power cords.
Step 3. Remove the cover (see “Removing the cover” on page 195).
Step 4. Remove the air baffle (see “Removing the air baffle” on page 199).
Step 5. Locate the microprocessor to be removed (see “System-board internal connectors” on page 28).
Step 6. Remove the heat sink.
Microprocessor
release lever
Microprocessor
Microprocessor
release lever
a. Identify which release lever is labeled as the first release lever to open and open it.
b. Open the second release lever on the microprocessor socket.
c. Open the microprocessor retainer.
Handle
Installation tool
• If using Installation Tool B, 1 lift the interlock latch and hold it up while you 2 twist the
microprocessor installation tool handle counterclockwise to the open position, and then
release the interlock latch. The following illustration of the installation tool shows the
location of the interlock latch and counterclockwise rotation of the handle before loading
the microprocessor.
b. Align the installation tool with the screws, as shown in the following graphic, and lower the
installation tool on the microprocessor. The installation tool rests flush on the socket only
when it is aligned correctly.
Microprocessor Alignment
pins
c. Using the following instructions for your installation tool to remove the microprocessor.
• If using Installation Tool A, gently twist the handle clockwise to the closed position and
lift the microprocessor out of the socket.
• If using Installation Tool B, gently twist the handle of the installation tool clockwise until it
locks in the “H” or “L” position, depending on the size of microprocessor, and then lift the
microprocessor out of the socket.
Handle
Installation
tool
Microprocessor
Microprocessor
Step 9. Install the new microprocessor (see “Replacing a microprocessor and heat sink” on page 287).
Attention: If you are replacing a microprocessor, use the empty installation tool that comes with
the new microprocessor to remove the microprocessor.
Step 10. If you do not intend to install a microprocessor on the socket, install the socket cover on the
microprocessor socket.
Attention: The pins on the socket are fragile. Any damage to the pins may require replacing the
system board.
If you are instructed to return the microprocessor, follow all packaging instructions, and use any packaging
materials for shipping that are supplied to you.
Important: Always use the microprocessor installation tool to install a microprocessor. Failing to use
the microprocessor installation tool may damage the microprocessor sockets on the system board. Any
damage to the microprocessor sockets may require replacing the system board.
• Be extremely careful, the microprocessor socket contacts are very fragile. Do not touch the
microprocessor socket contacts. Contaminants on the microprocessor contacts or microprocessor socket
contacts, such as oil from your skin, can cause connection failures between the contacts and the socket.
• Do not allow the thermal grease on the microprocessor and heat sink to come in contact with anything.
Contact with any surface can contaminate the thermal grease and the microprocessor socket.
• Do not use any tools or sharp objects to lift the locking levers on the microprocessor socket. Doing so
might result in permanent damage to the system board.
• Each microprocessor socket must always contain either a socket cover or a microprocessor and heat sink.
• Be sure to use only the installation tools provided with the new microprocessor to remove or install
the microprocessor. Do not use any other tool.
• When installing multiple microprocessors, open one microprocessor socket at a time to avoid damaging
other microprocessor socket contacts.
Note: Be sure to use the installation tool that comes with your microprocessor installation tool assembly.
• The server supports up to two multi-core microprocessors. See http://www.lenovo.com/ serverproven/
for a list of supported microprocessors.
• The first microprocessor must always be installed in microprocessor socket 1 on the system board.
• When one microprocessor is installed, the air baffle must be installed to provide proper system cooling.
• Do not remove the first microprocessor from the system board when you install the second
microprocessor.
• When you install the second microprocessor, you must also install additional memory, the fourth and sixth
fans. See “Installing a memory module” on page 215 for details about the installation sequence.
• Do not mix microprocessors with different cores in the same server.
• To ensure proper server operation when you install an additional microprocessor, use microprocessors
that have the same QuickPath Interconnect (QPI) link speed, integrated memory controller frequency, core
frequency, power segment, internal cache size, and type.
• Mixing microprocessors of different stepping levels within the same server model is supported.
• When mixing microprocessors with different stepping levels within the same server model, you do not
have to install the microprocessor with lowest stepping level and features in microprocessor socket 1.
• Both microprocessor voltage regulator modules are integrated on the system board.
• Read the documentation that comes with the microprocessor to determine whether you have to update
the server firmware. To download the latest level of server firmware and other code updates for your
server, go to http://www.ibm.com/support/ fixcentral.
• The microprocessor speeds are automatically set for this server; therefore, you do not have to set any
microprocessor frequency-selection jumpers or switches.
• If the thermal-grease protective cover (for example, a plastic cap or tape liner) is removed from the heat
sink, do not touch the thermal grease on the bottom of the heat sink or set down the heat sink. For more
information about applying or working with thermal grease, see “Thermal grease” on page 79.
Note: Removing the heat sink from the microprocessor destroys the even distribution of the thermal
grease and requires replacing the thermal grease.
• To order an additional optional microprocessor, contact your Lenovo sales representative or Lenovo
reseller.
There are two types of microprocessor installation tools. The tools are similar in function and design,
however Tool A has one setting for installing one size of microprocessor, and supports the following
families of microprocessors: E5-26xx, E5-46xx. Installation Tool B has two settings for installing two
different sizes of microprocessors. The settings that are marked on Tool B are “L” for smaller low core
microprocessors, and “H” for larger high core microprocessors. Installation Tool B supports the following
families of microprocessors: E5-26xx, E5-46xx, E5-26xx v2, E5-46xx v2.
Installation tool
Microprocessor
Cover
Microprocessor
Step 1. Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2. Turn off the server and peripheral devices and disconnect the power cords and all external cables.
Attention: When you handle static-sensitive devices, take precautions to avoid damage from
static electricity. For details about handling these devices, see “Handling static-sensitive devices”
on page 36.
Step 3. Remove the cover (see “Removing the cover” on page 195).
Step 4. Remove the air baffle (see “Removing the air baffle” on page 199).
Step 5. Rotate the heat sink retention module release lever to the open position.
a. Identify which release lever is labeled as the first release lever to open and open it.
b. Open the second release lever on the microprocessor socket.
c. Open the microprocessor retainer.
Attention: Do not touch the connectors on the microprocessor and the microprocessor socket.
Step 7. Install the microprocessor in the microprocessor socket:
a. Open the packaging that contains the new microprocessor installation tool assembly and
carefully remove the installation tool assembly from the package.
Microprocessor
Cover
c. Align the installation tool with the microprocessor socket. The installation tool rests flush on
the socket only if properly aligned.
d. Install the microprocessor using the following instructions for your installation tool.
• If using Installation Tool A, twist the handle on the microprocessor tool assembly
counterclockwise to the open position to insert the microprocessor into the socket, and
lift the installation tool out of the socket.
• If using Installation Tool B, twist the handle of the installation tool assembly counterclockwise
until the microprocessor is inserted into the socket, and lift the installation tool out of the
socket. The following illustration shows the tool handle in the open position.
L
H
Attention:
• Do not press the microprocessor into the socket.
• Make sure that the microprocessor is oriented and aligned correctly in the socket before
you try to close the microprocessor retainer.
• Do not touch the thermal material on the bottom of the heat sink or on top of the
microprocessor. Touching the thermal material will contaminate it.
Step 8. Remove the microprocessor socket cover, tape, or label from the surface of the microprocessor
socket, if one is present. Store the socket cover in a safe place.
Microprocessor
Attention: When you handle static-sensitive devices, take precautions to avoid damage from
static electricity. For details about handling these devices, see “Handling static-sensitive devices”
on page 36.
Step 9. Close the microprocessor socket release levers and retainer:
Microprocessor
release lever
Microprocessor
Microprocessor
release lever
Attention:
• If you are installing a new heat sink, do not set down the heat sink after you remove the
plastic cover.
• Do not touch the thermal grease on the bottom of the heat sink. Touching the thermal
grease will contaminate it.
Step 10. Install the heat sink.
Attention:
• Do not set down the heat sink after you remove the plastic cover.
a. Remove the plastic protective cover from the bottom of the heat sink.
b. Position the heat sink over the microprocessor. The heat sink is keyed to assist with proper
alignment.
c. Align and place the heat sink on top of the microprocessor in the retention bracket, thermal
material side down.
d. Press firmly on the heat sink.
e. Rotate the heat sink retention module release lever to the closed position and hook it
underneath the lock tab.
Step 11. Reinstall the air baffle (see “Replacing the air baffle” on page 200).
Step 12. Install the cover (see “Replacing the cover” on page 196).
Step 13. Slide the server into the rack.
Step 14. Reconnect the power cords and any cables that you removed.
Step 15. Turn on the peripheral devices and the server.
When you are installing the heat sink on the same microprocessor that it was removed from, make sure
that the following requirements are met:
• The thermal grease on the heat sink and microprocessor is not contaminated.
• Additional thermal grease is not added to the existing thermal grease on the heat sink and microprocessor.
To replace damaged or contaminated thermal grease on the microprocessor and heat sink, complete the
following steps:
0.02 mL of thermal
grease
Microprocessor
Note: If the grease is properly applied, approximately half of the grease will remain in the syringe.
Attention:
1. When you replace the system board, you must either update the server with the latest firmware or
restore the pre-existing firmware that the customer provides on a diskette or CD image. Make sure that
you have the latest firmware or a copy of the pre-existing firmware before you proceed.
2. Before removing any components or disconnecting any cables, keep note of their respective locations
and how they are connected to the system board.
3. When you replace the system board, make sure that you remove the Integrated Management Module
Advanced Upgrade and place it on the new system board. For information about the Advanced
Upgrade, see “Using the remote presence and blue-screen capture features” on page 111.
4. Before you replace the system board, make sure that you back up any features on demand (FoD) keys
that were enabled. Reactivate any Features on Demand features. Instructions for automating the
activation of features and installing activation keys is in the Lenovo Features on Demand User's Guide.
To download the document, go to https://fod.lenovo.com/lkms, log in, and click Help.
Step 1. Read the safety information that begins on “Safety” on page v, “Handling static-sensitive devices”
on page 36, and “Installation guidelines” on page 34.
Step 2. Turn off the server and any attached devices.
Step 3. Turn off the peripheral devices and disconnect all power cords.
Attention: When you replace the system board, you must either update the server with the
latest firmware or restore the pre-existing firmware that the customer provides on a diskette or
CD image. Make sure that you have the latest firmware or a copy of the pre-existing firmware
before you proceed.
Step 4. Pull the power supplies out of the rear of the server, just enough to disengage them from the server.
Step 5. Remove the cover (see “Removing the cover” on page 195).
Step 6. Remove all PCI riser-card assemblies and adapters (see “Removing a PCI riser-card assembly” on
page 221 and “Removing an adapter” on page 226).
Step 7. Remove the rear two hard-disk-drive kit, if any (see “Removing the rear two hard-disk-drive kit” on
page 224).
Step 8. Remove the air baffle (see “Removing the air baffle” on page 199).
Step 9. Remove the dual-port network adapter (see “Removing the dual-port network adapter” on page
235).
Step 10. Remove the ServeRAID adapter memory module (see “Removing the ServeRAID adapter memory
module” on page 232).
Step 11. Remove the memory modules and set them aside on a static-protective surface for reinstallation
(see “Removing a memory module” on page 214).
Note: Make a note of the location of each DIMM as you remove it, so that you can later reinstall it
in the same connector.
Step 12. Remove the USB embedded hypervisor flash device (see “Removing a USB embedded hypervisor
flash device” on page 264).
Attention:
1. Remove the socket covers from the microprocessor sockets on the new system board and
place them on the microprocessor sockets of the system board you are removing.
2. Do not allow the thermal grease to come in contact with anything, and keep each heat sink
paired with its microprocessor for reinstallation. Contact with any surface can compromise the
thermal grease and the microprocessor socket. A mismatch between the microprocessor and
its original heat sink can require the installation of a new heat sink.
Step 14. Remove the system battery (see “Removing the system battery” on page 266).
Step 15. Remove the hot-swap fans (see “Removing a hot-swap fan” on page 241).
Step 16. Remove the fan bracket (see “Removing the fan bracket” on page 243).
Step 17. Disconnect all cables from the system board. Make a list of each cable as you disconnect it; you
can then use this as a checklist when you install the new system board (see “Internal cable routing
and connectors” on page 179 for more information).
Attention: Disengage all latches, release tabs or locks on cable connectors when you disconnect
all cables from the system board. Failing to release them before removing the cables will damage
the cable sockets on the system board. The cable sockets on the system board are fragile. Any
damage to the cable sockets may require replacing the system board.
Step 18. Pull out and lift up the pin and the thumbscrews on each side of the system board.
Step 19. Remove the socket covers from the microprocessor sockets on the new system board and place
them on the microprocessor sockets of the old system board that you are removing.
Step 20. If you are instructed to return the system board, follow all packaging instructions, and use any
packaging materials for shipping that are supplied to you.
Attention: Make sure to place the socket covers for the microprocessor sockets on the system
board before returning the system board.
Attention:
1. When you reassemble the components in the server, be sure to route all cables carefully so that they are
not exposed to excessive pressure.
Step 1. Read the safety information that begins on “Safety” on page v, “Handling static-sensitive devices”
on page 36, and “Installation guidelines” on page 34.
Step 2. Align the system board at an angle, as shown in the illustration; then, rotate and lower it flat and
slide it back toward the rear of the server. Make sure that the rear connectors extend through
the rear of the chassis.
Step 3. Reconnect to the system board the cables that you disconnected. See “Internal cable routing and
connectors” on page 179.
Step 4. Rotate the system-board thumbscrews toward the rear of the server until the latch clicks into place.
Step 5. Install the fan bracket (see “Replacing the fan bracket” on page 245).
Step 6. Install the hot-swap fans (see “Replacing a hot-swap fan” on page 242).
Note: Remember to insert the hot-swap drive backplane cables in between the hot-swap fans as
shown in the illustration. Do not leave the cables on top of the hot-swap fans.
Step 7. Install the system battery (see “Replacing the system battery” on page 269).
Step 8. (Trained technician only) Install the microprocessor and heat sink (see “Replacing a microprocessor
and heat sink” on page 287).
Step 9. Install the USB embedded hypervisor flash device (see “Replacing a USB embedded hypervisor
flash device” on page 265).
Step 10. Install the memory modules (see “Installing a memory module” on page 215).
Step 11. Install the ServeRAID memory module (see “Replacing the ServeRAID adapter memory module” on
page 234).
Step 12. Install the dual-port network adapter (see “Replacing the dual-port network adapter” on page 237).
Step 13. Install the air baffle (see “Replacing the air baffle” on page 200).
Step 14. Install the PCI riser-card assemblies and adapters, if any were installed (see “Replacing an adapter”
on page 228 and “Replacing a PCI riser-card assembly” on page 222).
Step 15. Install the rear two hard-disk-drive kit, if any (see “Replacing the rear two hard-disk-drive kit” on
page 225).
Step 16. Install the cover (see “Replacing the cover” on page 196).
Step 17. Push the power supplies back into the server.
Step 18. Slide the server into the rack.
Step 19. Reconnect the power cords and any cables that you removed.
Step 20. Turn on the peripheral devices and the server.
Step 21. Start the Setup utility and reset the configuration.
• Set the system date and time.
• Set the power-on password.
• Reconfigure the server.
See “Using the Setup utility” on page 103 for more details.
Step 22. Either update the server with the latest RAID firmware or restore the pre-existing firmware from a
diskette or CD image.
Step 23. Update the UUID (see “Updating the Universal Unique Identifier (UUID)” on page 117).
Step 24. Update the DMI/SMBIOS (see “Updating the DMI/SMBIOS data” on page 119).
Step 25. Reactivate any Features on Demand features.
Event identifier
A hexadecimal identifier that uniquely identifies an event or class of events. In this documentation, the
event identifiers are prefixed with 0x and followed by eight characters.
Event description
The logged message string that appears for an event. When the event string is displayed in the
system-event log, information such as a specific component is displayed. In this documentation, that
additional information appears as variables, such as [arg1] or [arg2].
Explanation
Additional information to explain why the event occurred.
Severity
An indication of the level of concern for the condition. In the system-event log, severity is abbreviated to
the first character. The following severities can be displayed.
Info:
The event was recorded for audit purposes, usually a user action or a change of states that is
normal behavior.
Warning:
The event is not as severe as an error, but if possible, the condition should be corrected before it
becomes an error. It might also be a condition that requires additional monitoring or maintenance.
Error:
The event is a failure or critical condition that impairs service or an expected function.
Alert Category
Similar events are grouped together in categories. The alert category is in the following format:
severity - device
device is the specific device in the server that caused the event to be generated.
Serviceable
Whether user action is required to correct the problem.
CIM Information
The prefix of the message ID and the sequence number that is used by the CIM message registry.
SNMP Trap ID
The SNMP trap ID that is found in the SNMP alert management information base (MIB).
While you wait for IBM Support to call, you can perform the recommended actions for the event.
User response
The actions that you should perform to solve the event.
Perform the steps listed in this section in the order shown until the problem is solved. After you perform
all of the actions that are described in this field, if you cannot solve the problem, contact IBM Support.
Note: This list includes error codes and messages that might not apply to this machine type and model.
The following list shows the IMM2 error messages and suggested actions to correct the detected server
problems. For more information about IMM2, see the Integrated Management Module II User's Guide
at http://publib.boulder.ibm.com/infocenter/ systemx/documentation/topic/ com.lenovo.sysx.imm2.doc/
printable_doc.html.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - IMM Network event
SNMP Trap ID
37
CIM Information
Prefix: IMM ID: 0001
User Response
Information only; no action is required.
Severity
Error
Serviceable
No
Automatically notify support
No
Alert Category
System - SSL certification
SNMP Trap ID
22
CIM Information
Prefix: IMM ID: 0002
User Response
Make sure that the certificate that you are importing is correct and properly generated.
• 40000003-00000000 : Ethernet Data Rate modified from [arg1] to [arg2] by user [arg3].
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0003
User Response
Information only; no action is required.
• 40000004-00000000 : Ethernet Duplex setting modified from [arg1] to [arg2] by user [arg3].
This message is for the use case where A user modifies the Ethernet Port duplex setting.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0004
User Response
Information only; no action is required.
• 40000005-00000000 : Ethernet MTU setting modified from [arg1] to [arg2] by user [arg3].
This message is for the use case where a user modifies the Ethernet Port MTU setting.
CIM Information
Prefix: IMM ID: 0005
User Response
Information only; no action is required.
• 40000006-00000000 : Ethernet locally administered MAC address modified from [arg1] to [arg2]
by user [arg3].
This message is for the use case where a user modifies the Ethernet Port MAC address setting.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0006
User Response
Information only; no action is required.
CIM Information
Prefix: IMM ID: 0007
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - IMM Network event
SNMP Trap ID
37
CIM Information
Prefix: IMM ID: 0008
User Response
Information only; no action is required.
• 40000009-00000000 : IP address of network interface modified from [arg1] to [arg2] by user [arg3].
This message is for the use case where user modifies the IP address of a Management Controller.
Severity
Info
• 4000000a-00000000 : IP subnet mask of network interface modified from [arg1] to [arg2] by user
[arg3].
This message is for the use case where a user modifies the IP subnet mask of a Management Controller.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0010
User Response
Information only; no action is required.
• 4000000b-00000000 : IP address of default gateway modified from [arg1] to [arg2] by user [arg3].
This message is for the use case where a user modifies the default gateway IP address of a Management
Controller.
Severity
Info
Serviceable
CIM Information
Prefix: IMM ID: 0011
User Response
Information only; no action is required.
Severity
Warning
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0012
User Response
Information only; no action is required.
Severity
Warning
Serviceable
No
CIM Information
Prefix: IMM ID: 0013
User Response
Complete the following steps until the problem is solved:
1. Make sure that the IMM network cable is connected.
2. Make sure that there is a DHCP server on the network that can assign an IP address to the IMM.
• 4000000e-00000000 : Remote Login Successful. Login ID: [arg1] from [arg2] at IP address [arg3].
This message is for the use case where a user successfully logs in to a Management Controller.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Remote Login
SNMP Trap ID
30
CIM Information
Prefix: IMM ID: 0014
User Response
Information only; no action is required.
Severity
Info
Serviceable
CIM Information
Prefix: IMM ID: 0015
User Response
Information only; no action is required.
• 40000010-00000000 : Security: Userid: [arg1] had [arg2] login failures from WEB client at IP
address [arg3].
This message is for the use case where a user has failed to log in to a Management Controller from
a web browser.
Severity
Warning
Serviceable
No
Automatically notify support
No
Alert Category
System - Remote Login
SNMP Trap ID
30
CIM Information
Prefix: IMM ID: 0016
User Response
Complete the following steps until the problem is solved:
1. Make sure that the correct login ID and password are being used.
2. Have the system administrator reset the login ID or password.
• 40000011-00000000 : Security: Login ID: [arg1] had [arg2] login failures from CLI at [arg3].
This message is for the use case where a user has failed to log in to a Management Controller from
the Legacy CLI.
• 40000012-00000000 : Remote access attempt failed. Invalid userid or password received. Userid is
[arg1] from WEB browser at IP address [arg2].
This message is for the use case where a remote user has failed to establish a remote control session
from a Web browser session.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Remote Login
SNMP Trap ID
30
CIM Information
Prefix: IMM ID: 0018
User Response
Make sure that the correct login ID and password are being used.
• 40000013-00000000 : Remote access attempt failed. Invalid userid or password received. Userid is
[arg1] from TELNET client at IP address [arg2].
This message is for the use case where a user has failed to log in to a Management Controller from
a telnet session.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Remote Login
SNMP Trap ID
30
CIM Information
Prefix: IMM ID: 0019
User Response
Make sure that the correct login ID and password are being used.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0020
User Response
Information only; no action is required.
CIM Information
Prefix: IMM ID: 0021
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0022
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0023
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0024
User Response
Information only; no action is required.
CIM Information
Prefix: IMM ID: 0025
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0026
User Response
Information only; no action is required.
Severity
Info
CIM Information
Prefix: IMM ID: 0027
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - other
SNMP Trap ID
22
CIM Information
Prefix: IMM ID: 0028
User Response
If there was no operating-system error, complete the following steps until the problem is solved:
1. Reconfigure the watchdog timer to a higher value.
2. Make sure that the IMM Ethernet-over-USB interface is enabled.
3. Reinstall the RNDIS or cdc_ether device driver for the operating system.
4. Disable the watchdog.
If there was an operating-system error, check the integrity of the installed operating system.
Severity
Error
Serviceable
No
Automatically notify support
No
Alert Category
System - other
SNMP Trap ID
22
CIM Information
Prefix: IMM ID: 0029
User Response
Complete the following steps until the problem is solved:
1. Reconfigure the watchdog timer to a higher value.
2. Make sure that the IMM Ethernet over USB interface is enabled.
3. Reinstall the RNDIS or cdc_ether device driver for the operating system.
4. Disable the watchdog. Check the integrity of the installed operating system.
5. Update the IMM firmware. Important: Some cluster solutions require specific code levels or
coordinated code updates. If the device is part of a cluster solution, verify that the latest level of
code is supported for the cluster solution before you update the code.
Severity
Warning
Serviceable
No
Automatically notify support
No
Alert Category
System - other
SNMP Trap ID
22
CIM Information
Prefix: IMM ID: 0030
• 4000001f-00000000 : Please ensure that the Management Controller [arg1] is flashed with the
correct firmware. The Management Controller is unable to match its firmware to the server.
This message is for the use case where a Management Controller firmware version does not match
the server.
Severity
Error
Serviceable
No
Automatically notify support
No
Alert Category
System - other
SNMP Trap ID
22
CIM Information
Prefix: IMM ID: 0031
User Response
Update the IMM firmware to a version that the server supports. Important: Some cluster solutions
require specific code levels or coordinated code updates. If the device is part of a cluster solution,
verify that the latest level of code is supported for the cluster solution before you update the code.
• 40000020-00000000 : Management Controller [arg1] Reset was caused by restoring default values.
This message is for the use case where a Management Controller has been reset due to a user restoring
the configuration to default values.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
• 40000021-00000000 : Management Controller [arg1] clock has been set from NTP server [arg2].
This message is for the use case where a Management Controller clock has been set from the Network
Time Protocol server.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0033
User Response
Information only; no action is required.
• 40000022-00000000 : SSL data in the Management Controller [arg1] configuruation data is invalid.
Clearing configuration data region and disabling SSL.
This message is for the use case where a Management Controller has detected invalid SSL data in the
configuration data and is clearing the configuration data region and disabling the SSL.
Severity
Error
Serviceable
No
Automatically notify support
No
Alert Category
System - other
SNMP Trap ID
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0035
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
Automatically notify support
No
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Event Log 75% full
SNMP Trap ID
35
CIM Information
Prefix: IMM ID: 0037
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Event Log 75% full
Severity
Error
Serviceable
No
Automatically notify support
No
Alert Category
System - OS Timeout
SNMP Trap ID
21
CIM Information
Prefix: IMM ID: 0039
User Response
Complete the following steps until the problem is solved:
1. Reconfigure the watchdog timer to a higher value.
2. Make sure that the IMM Ethernet-over-USB interface is enabled.
3. Reinstall the RNDIS or cdc_ether device driver for the operating system.
4. Disable the watchdog.
5. Check the integrity of the installed operating system.
Severity
Info
Serviceable
No
• 40000029-00000000 : Security: Userid: [arg1] had [arg2] login failures from an SSH client at IP
address [arg3].
This message is for the use case where a user has failed to log in to a Management Controller from SSH.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Remote Login
SNMP Trap ID
30
CIM Information
Prefix: IMM ID: 0041
User Response
Complete the following steps until the problem is solved:
1. Make sure that the correct login ID and password are being used.
2. Have the system administrator reset the login ID or password.
• 4000002a-00000000 : [arg1] firmware mismatch internal to system [arg2]. Please attempt to flash
the [arg3] firmware.
This message is for the use case where a specific type of firmware mismatch has been detected.
Severity
Error
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0043
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
CIM Information
Prefix: IMM ID: 0044
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0045
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
Automatically notify support
No
CIM Information
Prefix: IMM ID: 0046
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0047
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
CIM Information
Prefix: IMM ID: 0048
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0049
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0051
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0052
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0053
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0054
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0055
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0056
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0057
User Response
Information only; no action is required.
• 4000003a-00000000 : IPv6 static address of network interface modified from [arg1] to [arg2]
by user [arg3].
A user modifies the IPv6 static address of a Management Controller
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0058
User Response
Information only; no action is required.
Severity
Warning
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0059
User Response
Complete the following steps until the problem is solved:
1. Make sure that the IMM network cable is connected.
2. Make sure that there is a DHCPv6 server on the network that can assign an IP address to
the IMM.
Severity
Error
Serviceable
No
Automatically notify support
No
Alert Category
System - Loader timeout
SNMP Trap ID
26
CIM Information
Prefix: IMM ID: 0060
User Response
• 4000003d-00000000 : Telnet port number changed from [arg1] to [arg2] by user [arg3].
A user has modified the telnet port number
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0061
User Response
Information only; no action is required.
• 4000003e-00000000 : SSH port number changed from [arg1] to [arg2] by user [arg3].
A user has modified the SSH port number
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0062
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0063
User Response
Information only; no action is required.
• 40000040-00000000 : Web-HTTPS port number changed from [arg1] to [arg2] by user [arg3].
A user has modified the Web HTTPS port number
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0064
User Response
Information only; no action is required.
• 40000041-00000000 : CIM/XML HTTP port number changed from [arg1] to [arg2] by user [arg3].
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0065
User Response
Information only; no action is required.
• 40000042-00000000 : CIM/XML HTTPS port number changed from [arg1] to [arg2] by user [arg3].
A user has modified the CIM HTTPS port number
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0066
User Response
Information only; no action is required.
• 40000043-00000000 : SNMP Agent port number changed from [arg1] to [arg2] by user [arg3].
A user has modified the SNMP Agent port number
CIM Information
Prefix: IMM ID: 0067
User Response
Information only; no action is required.
• 40000044-00000000 : SNMP Traps port number changed from [arg1] to [arg2] by user [arg3].
A user has modified the SNMP Traps port number
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0068
User Response
Information only; no action is required.
• 40000045-00000000 : Syslog port number changed from [arg1] to [arg2] by user [arg3].
A user has modified the Syslog receiver port number
Severity
CIM Information
Prefix: IMM ID: 0069
User Response
Information only; no action is required.
• 40000046-00000000 : Remote Presence port number changed from [arg1] to [arg2] by user [arg3].
A user has modified the Remote Presence port number
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0070
User Response
Information only; no action is required.
Severity
Info
Serviceable
CIM Information
Prefix: IMM ID: 0071
User Response
Information only; no action is required.
• 40000048-00000000 : Inventory data changed for device [arg1], new device data hash=[arg2], new
master data hash=[arg3] .
Something has caused the physical inventory to change
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0072
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
CIM Information
Prefix: IMM ID: 0073
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0074
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
Automatically notify support
No
CIM Information
Prefix: IMM ID: 0075
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0076
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
Automatically notify support
No
CIM Information
Prefix: IMM ID: 0077
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0078
User Response
Information only; no action is required.
• 4000004f-00000000 : Date and Time set by user [arg1]: Date=[arg2], Time-[arg3], DST
Auto-adjust=[arg4], Timezone=[arg5].
A user configured the Date and Time settings
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
CIM Information
Prefix: IMM ID: 0079
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0080
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
CIM Information
Prefix: IMM ID: 0081
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0082
User Response
Information only; no action is required.
• 40000053-00000000 : Server [arg1] scheduled for every [arg2] at [arg3] by user [arg4].
A user configured a recurring Server Power Action
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0084
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0085
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0086
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0087
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0088
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0089
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0090
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0091
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0092
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0093
User Response
Information only; no action is required.
CIM Information
Prefix: IMM ID: 0094
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0095
User Response
Information only; no action is required.
CIM Information
Prefix: IMM ID: 0096
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0097
User Response
Information only; no action is required.
Severity
Info
CIM Information
Prefix: IMM ID: 0098
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0099
User Response
Information only; no action is required.
CIM Information
Prefix: IMM ID: 0100
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0101
User Response
Information only; no action is required.
Severity
Info
CIM Information
Prefix: IMM ID: 0102
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0103
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
CIM Information
Prefix: IMM ID: 0104
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0105
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
Automatically notify support
No
CIM Information
Prefix: IMM ID: 0106
User Response
Information only; no action is required.
• 4000006b-00000000 : SSH Client key imported for user [arg1] from [arg2].
User imported an SSH Client key
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0107
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
CIM Information
Prefix: IMM ID: 0108
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0109
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0111
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
• 40000071-00000000 : The power cap value changed from [arg1] watts to [arg2] watts by user [arg3].
Power Cap values changed by user
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0113
User Response
Information only; no action is required.
• 40000072-00000000 : The minimum power cap value changed from [arg1] watts to [arg2] watts.
Minimum Power Cap value changed
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0114
User Response
• 40000073-00000000 : The maximum power cap value changed from [arg1] watts to [arg2] watts.
Maximum Power Cap value changed
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0115
User Response
Information only; no action is required.
• 40000074-00000000 : The soft minimum power cap value changed from [arg1] watts to [arg2] watts.
Soft Minimum Power Cap value changed
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0116
User Response
Information only; no action is required.
Severity
Warning
Serviceable
No
Automatically notify support
No
Alert Category
Warning - Power
SNMP Trap ID
164
CIM Information
Prefix: IMM ID: 0117
User Response
Information only; no action is required.
• 40000076-00000000 : The new minimum power cap value exceeded the power cap value.
Minimum Power Cap exceeds Power Cap
Severity
Warning
Serviceable
No
Automatically notify support
No
Alert Category
Warning - Power
SNMP Trap ID
164
CIM Information
Prefix: IMM ID: 0118
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0119
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0120
User Response
Information only; no action is required.
• 40000079-00000000 : Static Power Savings mode has been turned on by user [arg1].
Static Power Savings mode turned on by user
CIM Information
Prefix: IMM ID: 0121
User Response
Information only; no action is required.
• 4000007a-00000000 : Static Power Savings mode has been turned off by user [arg1].
Static Power Savings mode turned off by user
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0122
User Response
Information only; no action is required.
• 4000007b-00000000 : Dynamic Power Savings mode has been turned on by user [arg1].
Dynamic Power Savings mode turned on by user
Severity
CIM Information
Prefix: IMM ID: 0123
User Response
Information only; no action is required.
• 4000007c-00000000 : Dynamic Power Savings mode has been turned off by user [arg1].
Dynamic Power Savings mode turned off by user
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0124
User Response
Information only; no action is required.
Severity
Info
Serviceable
CIM Information
Prefix: IMM ID: 0125
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0126
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
Automatically notify support
CIM Information
Prefix: IMM ID: 0127
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0128
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
CIM Information
Prefix: IMM ID: 0129
User Response
Information only; no action is required.
• 40000082-00000000 : The measured power value has returned below the power cap value.
Power exceeded cap recovered
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Warning - Power
SNMP Trap ID
164
CIM Information
Prefix: IMM ID: 0130
User Response
Information only; no action is required.
• 40000083-00000000 : The new minimum power cap value has returned below the power cap value.
Minimum Power Cap exceeds Power Cap recovered
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Warning - Power
SNMP Trap ID
• 40000084-00000000 : IMM firmware mismatch between nodes [arg1] and [arg2]. Please attempt to
flash the IMM firmware to the same level on all nodes.
A mismatch of IMM firmware has been detected between nodes
Severity
Error
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
22
CIM Information
Prefix: IMM ID: 0132
User Response
Attempt to flash the IMM firmware to the same level on all nodes.
• 40000085-00000000 : FPGA firmware mismatch between nodes [arg1] and [arg2]. Please attempt
to flash the FPGA firmware to the same level on all nodes.
A mismatch of FPGA firmware has been detected between nodes
Severity
Error
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
22
Severity
Info
Serviceable
No
Automatically notify support
Yes
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0134
User Response
Information only; no action is required.
Severity
Info
Serviceable
No
Automatically notify support
Yes
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0135
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0136
User Response
Information only; no action is required.
Severity
Error
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
22
CIM Information
1. Turn off the server and disconnect it from the power source. You must disconnect the server
from ac power to reset the IMM.
2. After 45 seconds, reconnect the server to the power source and turn on the server.
3. Retry the operation.
Severity
Error
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
22
CIM Information
Prefix: IMM ID: 0138
User Response
1. Turn off the server and disconnect it from the power source. You must disconnect the server
from ac power to reset the IMM.
2. After 45 seconds, reconnect the server to the power source and turn on the server.
3. Retry the operation.
Severity
Info
Serviceable
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Voltage
SNMP Trap ID
13
CIM Information
Prefix: PLAT ID: 0476
User Response
Replace the system battery.
Severity
Error
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Fan Failure
SNMP Trap ID
11
CIM Information
Prefix: PLAT ID: 0480
User Response
1. Reseat the failing fan n, which is indicated by a lit LED near the fan connector on the system
board.
2. Replace the failing fan. (n = fan number)
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Fan Failure
SNMP Trap ID
11
CIM Information
Prefix: PLAT ID: 0480
User Response
1. Reseat the failing fan n, which is indicated by a lit LED near the fan connector on the system
board.
2. Replace the failing fan. (n = fan number)
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Fan Failure
SNMP Trap ID
11
CIM Information
1. Reseat the failing fan n, which is indicated by a lit LED near the fan connector on the system
board.
2. Replace the failing fan. (n = fan number)
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Fan Failure
SNMP Trap ID
11
CIM Information
Prefix: PLAT ID: 0480
User Response
1. Reseat the failing fan n, which is indicated by a lit LED near the fan connector on the system
board.
2. Replace the failing fan. (n = fan number)
Severity
Warning
Serviceable
Yes
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications.(see
Features and specifications for more information)
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Temperature
SNMP Trap ID
12
CIM Information
Prefix: PLAT ID: 0490
User Response
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications.(see
Features and specifications for more information)
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Temperature
SNMP Trap ID
12
CIM Information
Prefix: PLAT ID: 0490
User Response
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications.(see
Features and specifications for more information)
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Temperature
SNMP Trap ID
12
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications.(see
Features and specifications for more information)
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Temperature
SNMP Trap ID
12
CIM Information
Prefix: PLAT ID: 0490
User Response
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications.(see
Features and specifications for more information)
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications.(see
Features and specifications for more information)
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Temperature
SNMP Trap ID
12
CIM Information
Prefix: PLAT ID: 0490
User Response
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Temperature
SNMP Trap ID
12
CIM Information
Prefix: PLAT ID: 0490
User Response
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications.(see
Features and specifications for more information)
Severity
Warning
Serviceable
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications.(see
Features and specifications for more information)
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Temperature
SNMP Trap ID
12
CIM Information
Prefix: PLAT ID: 0490
User Response
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications.(see
Features and specifications for more information)
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Temperature
SNMP Trap ID
12
CIM Information
Prefix: PLAT ID: 0490
User Response
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications.(see
Features and specifications for more information)
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Temperature
SNMP Trap ID
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications.(see
Features and specifications for more information)
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Temperature
SNMP Trap ID
12
CIM Information
Prefix: PLAT ID: 0490
User Response
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications.(see
Features and specifications for more information)
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications.(see
Features and specifications for more information)
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0494
User Response
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0494
User Response
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications.(see
Features and specifications for more information)
Severity
Error
Serviceable
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications.(see
Features and specifications for more information)
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0494
User Response
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications.(see
Features and specifications for more information)
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0494
User Response
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications.(see
Features and specifications for more information)
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications.(see
Features and specifications for more information)
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0494
User Response
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications.(see
Features and specifications for more information)
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications.(see
Features and specifications for more information)
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0494
User Response
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0494
User Response
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications.(see
Features and specifications for more information)
Severity
Error
Serviceable
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications.(see
Features and specifications for more information)
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0494
User Response
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications.(see
Features and specifications for more information)
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Voltage
SNMP Trap ID
1
CIM Information
Prefix: PLAT ID: 0494
User Response
If the specified sensor is Planar 3.3V or Planar 5V, (trained technician only) replace the system board.
If the specified sensor is Planar 12V, complete the following steps until the problem is solved:
1. Check power supply n LED.
2. Remove the failing power supply.
3. (Trained technician only) Replace the system board. (n = power supply number)
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications.(see
Features and specifications for more information)
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0498
User Response
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications.(see
Features and specifications for more information)
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications.(see
Features and specifications for more information)
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0498
User Response
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0498
User Response
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications.(see
Features and specifications for more information)
Severity
Error
Serviceable
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications.(see
Features and specifications for more information)
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0498
User Response
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications.(see
Features and specifications for more information)
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0498
User Response
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications.(see
Features and specifications for more information)
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications.(see
Features and specifications for more information)
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0498
User Response
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications.(see
Features and specifications for more information)
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications.(see
Features and specifications for more information)
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0498
User Response
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0498
User Response
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications.(see
Features and specifications for more information)
Severity
Info
Serviceable
No
CIM Information
Prefix: PLAT ID: 0509
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0509
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
CIM Information
Prefix: PLAT ID: 0508
User Response
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Temperature
SNMP Trap ID
12
CIM Information
Prefix: PLAT ID: 0520
User Response
1. Check the IBM support site for service bulletins or firmware updates that apply to this GPT error.
2. Set the UEFI setting DISK GPT Recovery to Automatic.
3. Replace the corrupt disk.
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Other
SNMP Trap ID
60
CIM Information
Prefix: PLAT ID: 0520
User Response
Complete the following step to solve PCI I/O resource errors:
1. Go to F1 Setup
2. System Settings
3. Device and I/O ports
4. PCI 64 bit Resource and choose enable
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Other
SNMP Trap ID
60
CIM Information
Prefix: PLAT ID: 0520
User Response
1. Complete the administrative tasks that require the TPM physical presence switch to be in
the ON position.
2. Restore the physical presence switch to the OFF position.
3. Reboot the system.
4. (Trained technician only) If the error continues, replace the planar.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
1. Make sure that the fans are operating, that there are no obstructions to the airflow (front and
rear of the server), that the air baffles are in place and correctly installed, and that the server
cover is installed and completely closed.
2. Check the ambient temperature. You must be operating within the specifications (see Features
and specifications for more information).
3. Make sure that the heat sink for microprocessor n is installed correctly.
4. (Trained technician only) Replace microprocessor n. (n = microprocessor number)
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0522
User Response
1. Make sure that the fans are operating, that there are no obstructions to the airflow (front and
rear of the server), that the air baffles are in place and correctly installed, and that the server
cover is installed and completely closed.
2. Check the ambient temperature. You must be operating within the specifications (see Features
and specifications for more information).
3. Make sure that the heat sink for microprocessor n is installed correctly.
4. (Trained technician only) Replace microprocessor n. (n = microprocessor number)
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Voltage
SNMP Trap ID
1
CIM Information
Prefix: PLAT ID: 0522
User Response
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
1. Make sure that there are no obstructions, such as bundled cables, to the airflow from the
power-supply fan.
2. Replace power supply n. (n = power supply number)
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Fan Failure
SNMP Trap ID
11
CIM Information
Prefix: PLAT ID: 0522
User Response
1. Make sure that there are no obstructions, such as bundled cables, to the airflow from the
power-supply fan.
2. Replace power supply n. (n = power supply number)
1. Make sure that there are no obstructions, such as bundled cables, to the airflow from the
power-supply fan.
2. Use the IBM Power Configurator utility to ensure current system power consumption
is under limitation. For more information and to download the utility, go to
http://www-03.ibm.com/systems/bladecenter/resources/powerconfig.html.
3. Replace power supply n. (n = power supply number)
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Power
SNMP Trap ID
4
CIM Information
Prefix: PLAT ID: 0522
User Response
1. Make sure that there are no obstructions, such as bundled cables, to the airflow from the
power-supply fan.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0522
User Response
None
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0522
User Response
None
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0522
User Response
1. If enabling TXT is not required, disable TXT from the Setup Utility.
2. If enabling TXT is required, verify that the TPM is enabled and activated from the Setup Utility.
3. If the problem remains, contact your service representative. nvDIMM Flash :
Severity
Error
Serviceable
Yes
Severity
Error
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0522
User Response
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0522
User Response
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0522
User Response
Severity
1. Make sure that the fans are operating, that there are no obstructions to the airflow (front and
rear of the server), that the air baffle is in place and correctly installed, and that the server cover
is installed and completely closed.
2. Check the ambient temperature. You must be operating within the specifications (see Server
Features and specifications for more information).
3. Make sure that the heat sink for microprocessor n.
4. (Trained technician only) Replace microprocessor n. (n = microprocessor number)
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0524
User Response
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Power
SNMP Trap ID
4
CIM Information
Prefix: PLAT ID: 0530
User Response
If the specified sensor is one of the Pwr Rail A-H Fault, please follow actions in "Power Problems and
Solving Power Problems".
Severity
Error
Serviceable
Yes
Automatically notify support
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Power
SNMP Trap ID
4
CIM Information
Prefix: PLAT ID: 0530
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0530
User Response
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0536
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0536
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Warning - Redundant Power Supply
SNMP Trap ID
10
CIM Information
Prefix: PLAT ID: 0561
User Response
No action; information only.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Redundant Power Supply
SNMP Trap ID
9
CIM Information
Prefix: PLAT ID: 0802
User Response
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Fan Failure
SNMP Trap ID
11
CIM Information
Prefix: PLAT ID: 0802
User Response
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Fan Failure
SNMP Trap ID
11
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0802
User Response
1. Check the system-event log for DIMM failure events (uncorrectable or PFA) and correct the
failures.
2. Re-enable mirroring in the Setup utility.
Severity
1. Non-redundant sufficient: Power load will be handled by remaining power supply, though the
system may throttle to avoid a power supply over-current condition.
2. Replace the power supply with higher rated power.
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Memory
SNMP Trap ID
43
CIM Information
Prefix: PLAT ID: 0806
User Response
1. Check the system-event log for DIMM failure events (uncorrectable or PFA) and correct the
failures.
2. Re-enable mirroring in the Setup utility.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Redundant Power Supply
SNMP Trap ID
9
CIM Information
Prefix: PLAT ID: 0810
User Response
1. Power load may be handled by remaining power supply. The system will attempt to throttle to
avoid a power supply over-current condition. But a system shutdown may happen anyway if
the power load is too great.
2. Reduce the total power consumption by removing newly added or unused options like drives or
adaptors.
3. Use the IBM Power Configurator utility to determine current system power
consumption. For more information and to download the utility, go to
http://www-03.ibm.com/systems/bladecenter/resources/powerconfig.html.
4. Replace the power supply with higher rated power.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Fan Failure
SNMP Trap ID
11
CIM Information
Prefix: PLAT ID: 0810
User Response
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0810
User Response
1. Check the system-event log for DIMM failure events (uncorrectable or PFA) and correct the
failures.
2. Re-enable mirroring in the Setup utility.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - CPU
SNMP Trap ID
40
CIM Information
Prefix: PLAT ID: 0042
1. Make sure that the latest level of firmware and device drivers are installed for all adapters and
standard devices, such as Ethernet, SCSI, and SAS. Important: Some cluster solutions require
specific code levels or coordinated code updates. If the device is part of a cluster solution, verify
that the latest level of code is supported for the cluster solution before you update the code.
2. Update the firmware (UEFI and IMM) to the latest level (Updating the firmware).
3. Run the DSA program.
4. Reseat the adapter.
5. Replace the adapter.
6. (Trained technician only) Replace microprocessor n.
7. (Trained technician only) Replace the system board. (n = microprocessor number)
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - CPU
SNMP Trap ID
40
CIM Information
Prefix: PLAT ID: 0042
User Response
1. Make sure that the latest level of firmware and device drivers are installed for all adapters and
standard devices, such as Ethernet, SCSI, and SAS. Important: Some cluster solutions require
specific code levels or coordinated code updates. If the device is part of a cluster solution, verify
that the latest level of code is supported for the cluster solution before you update the code.
2. Update the firmware (UEFI and IMM) to the latest level (Updating the firmware).
3. Run the DSA program.
4. Reseat the adapter.
5. Replace the adapter.
6. (Trained technician only) Replace microprocessor n.
7. (Trained technician only) Replace the system board. (n = microprocessor number)
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0084
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0084
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Power Off
SNMP Trap ID
23
CIM Information
Prefix: PLAT ID: 0106
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0162
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0162
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0162
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0162
User Response
No action; information only.
Severity
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0162
User Response
No action; information only.
Severity
Info
Serviceable
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0162
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0162
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0162
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0162
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0162
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0162
User Response
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0162
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0162
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0162
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0162
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0162
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0162
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0162
User Response
No action; information only.
Severity
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0162
User Response
No action; information only.
Severity
Info
Serviceable
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0162
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0162
User Response
No action; information only.
Severity
Error
Serviceable
Yes
Automatically notify support
No
1. Make sure the server meets the minimum configuration to start (see Power-supply LEDs).
2. Recover the server firmware from the backup page: a. Restart the server. b. At the prompt,
press F3 to recover the firmware.
3. Update the server firmware on the primary page. Important: Some cluster solutions require
specific code levels or coordinated code updates. If the device is part of a cluster solution, verify
that the latest level of code is supported for the cluster solution before you update the code.
4. Remove components one at a time, restarting the server each time, to see if the problem
goes away.
5. If the problem remains, (trained technician only) replace the system board.
Firmware Error : Sys Boot Status :
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0132
User Response
1. Make sure the server meets the minimum configuration to start (see Power-supply LEDs).
2. Update the server firmware on the primary page. Important: Some cluster solutions require
specific code levels or coordinated code updates. If the device is part of a cluster solution, verify
that the latest level of code is supported for the cluster solution before you update the code.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0770
User Response
This is a UEFI detected event. The UEFI(POST) error code for this event can be found in the logged
IMM message text. Please refer to the UEFI(POST) error code in the "UEFI(POST) error code" section
of the Information Center for the appropriate user response. Firmware Error : Sys Boot Status :
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0764
User Response
This is a UEFI detected event. The UEFI(POST) error code for this event can be found in the logged
IMM message text. Please refer to the UEFI(POST) error code in the "UEFI(POST) error code" section
of the Information Center for the appropriate user response. Firmware Error : Sys Boot Status :
Severity
Error
Serviceable
Yes
Automatically notify support
Severity
Info
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
40
CIM Information
Prefix: PLAT ID: 0850
User Response
1. Make sure the server meets the minimum configuration to start (see Power-supply LEDs).
2. Recover the server firmware from the backup page: a. Restart the server. b. At the prompt,
press F3 to recover the firmware.
3. Update the server firmware to the latest level (see Updating the firmware). Important: Some
cluster solutions require specific code levels or coordinated code updates. If the device is part
of a cluster solution, verify that the latest level of code is supported for the cluster solution
before you update the code.
4. Remove components one at a time, restarting the server each time, to see if the problem
goes away.
5. If the problem remains, (trained service technician) replace the system board. Firmware Error
: Sys Boot Status :
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - CPU
SNMP Trap ID
40
CIM Information
Prefix: PLAT ID: 0050
User Response
This is a UEFI detected event. The UEFI(POST) error code for this event can be found in the logged
IMM message text. Please refer to the UEFI(POST) error code in the "UEFI(POST) error code" section
of the Info Center for the appropriate user response. Firmware Error : Sys Boot Status :
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0184
User Response
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0222
User Response
If the NMI button has not been pressed, complete the following steps:
1. Make sure that the NMI button is not pressed.
2. Replace the operator information panel cable.
3. Replace the operator information panel.
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Other
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0330
User Response
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0330
User Response
Severity
Error
Serviceable
Yes
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0368
User Response
No action; information only.
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Other
SNMP Trap ID
60
CIM Information
Prefix: PLAT ID: 0398
User Response
1. Turn off the server and disconnect the power cords. Reconnect the power cords and restart
the server.
2. If the problem remains, (trained technician only) replace the system board.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0036
User Response
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0036
User Response
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications.(see
Features and specifications for more information)
4. Make sure that the heat sink for microprocessor n is installed correctly.
5. (Trained technician only) Replace microprocessor n. (n = microprocessor number)
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Power
SNMP Trap ID
4
CIM Information
Prefix: PLAT ID: 0086
User Response
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0108
User Response
No action; information only.
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0138
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the problem follows the DIMM, replace the failing DIMM.
4. (Trained technician only) Remove the affected microprocessor and check the microprocessor
socket pins for any damaged pins. If a damage is found, replace the system board.
5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM
connector. If the connector contains any foreign material or is damaged, replace the system
board.
6. (Trained technician only) Replace the affected microprocessor.
7. Manually re-enable all affected DIMMs. Update firmware version to the latest level and
reconnect to server to the power source and restart the server.
8. (Trained Service technician only) Replace the affected microprocessor.
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0138
User Response
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the problem follows the DIMM, replace the failing DIMM.
4. (Trained technician only) Remove the affected microprocessor and check the microprocessor
socket pins for any damaged pins. If a damage is found, replace the system board.
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0138
User Response
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the problem follows the DIMM, replace the failing DIMM.
4. (Trained technician only) Remove the affected microprocessor and check the microprocessor
socket pins for any damaged pins. If a damage is found, replace the system board.
5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM
connector. If the connector contains any foreign material or is damaged, replace the system
board.
6. (Trained technician only) Replace the affected microprocessor.
7. Manually re-enable all affected DIMMs. Update firmware version to the latest level and
reconnect to server to the power source and restart the server.
8. (Trained Service technician only) Replace the affected microprocessor.
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0138
User Response
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the problem follows the DIMM, replace the failing DIMM.
4. (Trained technician only) Remove the affected microprocessor and check the microprocessor
socket pins for any damaged pins. If a damage is found, replace the system board.
5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM
connector. If the connector contains any foreign material or is damaged, replace the system
board.
6. (Trained technician only) Replace the affected microprocessor.
7. Manually re-enable all affected DIMMs. Update firmware version to the latest level and
reconnect to server to the power source and restart the server.
8. (Trained Service technician only) Replace the affected microprocessor.
Severity
Error
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the problem follows the DIMM, replace the failing DIMM.
4. (Trained technician only) Remove the affected microprocessor and check the microprocessor
socket pins for any damaged pins. If a damage is found, replace the system board.
5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM
connector. If the connector contains any foreign material or is damaged, replace the system
board.
6. (Trained technician only) Replace the affected microprocessor.
7. Manually re-enable all affected DIMMs. Update firmware version to the latest level and
reconnect to server to the power source and restart the server.
8. (Trained Service technician only) Replace the affected microprocessor.
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the problem follows the DIMM, replace the failing DIMM.
4. (Trained technician only) Remove the affected microprocessor and check the microprocessor
socket pins for any damaged pins. If a damage is found, replace the system board.
5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM
connector. If the connector contains any foreign material or is damaged, replace the system
board.
6. (Trained technician only) Replace the affected microprocessor.
7. Manually re-enable all affected DIMMs. Update firmware version to the latest level and
reconnect to server to the power source and restart the server.
8. (Trained Service technician only) Replace the affected microprocessor.
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0138
User Response
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the problem follows the DIMM, replace the failing DIMM.
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0138
User Response
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the problem follows the DIMM, replace the failing DIMM.
4. (Trained technician only) Remove the affected microprocessor and check the microprocessor
socket pins for any damaged pins. If a damage is found, replace the system board.
5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM
connector. If the connector contains any foreign material or is damaged, replace the system
board.
6. (Trained technician only) Replace the affected microprocessor.
7. Manually re-enable all affected DIMMs. Update firmware version to the latest level and
reconnect to server to the power source and restart the server.
8. (Trained Service technician only) Replace the affected microprocessor.
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0138
User Response
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the problem follows the DIMM, replace the failing DIMM.
4. (Trained technician only) Remove the affected microprocessor and check the microprocessor
socket pins for any damaged pins. If a damage is found, replace the system board.
5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM
connector. If the connector contains any foreign material or is damaged, replace the system
board.
6. (Trained technician only) Replace the affected microprocessor.
7. Manually re-enable all affected DIMMs. Update firmware version to the latest level and
reconnect to server to the power source and restart the server.
8. (Trained Service technician only) Replace the affected microprocessor.
Severity
Error
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the problem follows the DIMM, replace the failing DIMM.
4. (Trained technician only) Remove the affected microprocessor and check the microprocessor
socket pins for any damaged pins. If a damage is found, replace the system board.
5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM
connector. If the connector contains any foreign material or is damaged, replace the system
board.
6. (Trained technician only) Replace the affected microprocessor.
7. Manually re-enable all affected DIMMs. Update firmware version to the latest level and
reconnect to server to the power source and restart the server.
8. (Trained Service technician only) Replace the affected microprocessor.
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the problem follows the DIMM, replace the failing DIMM.
4. (Trained technician only) Remove the affected microprocessor and check the microprocessor
socket pins for any damaged pins. If a damage is found, replace the system board.
5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM
connector. If the connector contains any foreign material or is damaged, replace the system
board.
6. (Trained technician only) Replace the affected microprocessor.
7. Manually re-enable all affected DIMMs. Update firmware version to the latest level and
reconnect to server to the power source and restart the server.
8. (Trained Service technician only) Replace the affected microprocessor.
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0138
User Response
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the problem follows the DIMM, replace the failing DIMM.
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0138
User Response
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the problem follows the DIMM, replace the failing DIMM.
4. (Trained technician only) Remove the affected microprocessor and check the microprocessor
socket pins for any damaged pins. If a damage is found, replace the system board.
5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM
connector. If the connector contains any foreign material or is damaged, replace the system
board.
6. (Trained technician only) Replace the affected microprocessor.
7. Manually re-enable all affected DIMMs. Update firmware version to the latest level and
reconnect to server to the power source and restart the server.
8. (Trained Service technician only) Replace the affected microprocessor.
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0138
User Response
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the problem follows the DIMM, replace the failing DIMM.
4. (Trained technician only) Remove the affected microprocessor and check the microprocessor
socket pins for any damaged pins. If a damage is found, replace the system board.
5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM
connector. If the connector contains any foreign material or is damaged, replace the system
board.
6. (Trained technician only) Replace the affected microprocessor.
7. Manually re-enable all affected DIMMs. Update firmware version to the latest level and
reconnect to server to the power source and restart the server.
8. (Trained Service technician only) Replace the affected microprocessor.
Severity
Error
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the problem follows the DIMM, replace the failing DIMM.
4. (Trained technician only) Remove the affected microprocessor and check the microprocessor
socket pins for any damaged pins. If a damage is found, replace the system board.
5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM
connector. If the connector contains any foreign material or is damaged, replace the system
board.
6. (Trained technician only) Replace the affected microprocessor.
7. Manually re-enable all affected DIMMs. Update firmware version to the latest level and
reconnect to server to the power source and restart the server.
8. (Trained Service technician only) Replace the affected microprocessor.
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the problem follows the DIMM, replace the failing DIMM.
4. (Trained technician only) Remove the affected microprocessor and check the microprocessor
socket pins for any damaged pins. If a damage is found, replace the system board.
5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM
connector. If the connector contains any foreign material or is damaged, replace the system
board.
6. (Trained technician only) Replace the affected microprocessor.
7. Manually re-enable all affected DIMMs. Update firmware version to the latest level and
reconnect to server to the power source and restart the server.
8. (Trained Service technician only) Replace the affected microprocessor.
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0138
User Response
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the problem follows the DIMM, replace the failing DIMM.
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0138
User Response
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the problem follows the DIMM, replace the failing DIMM.
4. (Trained technician only) Remove the affected microprocessor and check the microprocessor
socket pins for any damaged pins. If a damage is found, replace the system board.
5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM
connector. If the connector contains any foreign material or is damaged, replace the system
board.
6. (Trained technician only) Replace the affected microprocessor.
7. Manually re-enable all affected DIMMs. Update firmware version to the latest level and
reconnect to server to the power source and restart the server.
8. (Trained Service technician only) Replace the affected microprocessor.
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0138
User Response
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the problem follows the DIMM, replace the failing DIMM.
4. (Trained technician only) Remove the affected microprocessor and check the microprocessor
socket pins for any damaged pins. If a damage is found, replace the system board.
5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM
connector. If the connector contains any foreign material or is damaged, replace the system
board.
6. (Trained technician only) Replace the affected microprocessor.
7. Manually re-enable all affected DIMMs. Update firmware version to the latest level and
reconnect to server to the power source and restart the server.
8. (Trained Service technician only) Replace the affected microprocessor.
Severity
Error
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the problem follows the DIMM, replace the failing DIMM.
4. (Trained technician only) Remove the affected microprocessor and check the microprocessor
socket pins for any damaged pins. If a damage is found, replace the system board.
5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM
connector. If the connector contains any foreign material or is damaged, replace the system
board.
6. (Trained technician only) Replace the affected microprocessor.
7. Manually re-enable all affected DIMMs. Update firmware version to the latest level and
reconnect to server to the power source and restart the server.
8. (Trained Service technician only) Replace the affected microprocessor.
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the problem follows the DIMM, replace the failing DIMM.
4. (Trained technician only) Remove the affected microprocessor and check the microprocessor
socket pins for any damaged pins. If a damage is found, replace the system board.
5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM
connector. If the connector contains any foreign material or is damaged, replace the system
board.
6. (Trained technician only) Replace the affected microprocessor.
7. Manually re-enable all affected DIMMs. Update firmware version to the latest level and
reconnect to server to the power source and restart the server.
8. (Trained Service technician only) Replace the affected microprocessor.
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0138
User Response
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the problem follows the DIMM, replace the failing DIMM.
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0138
User Response
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the problem follows the DIMM, replace the failing DIMM.
4. (Trained technician only) Remove the affected microprocessor and check the microprocessor
socket pins for any damaged pins. If a damage is found, replace the system board.
5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM
connector. If the connector contains any foreign material or is damaged, replace the system
board.
6. (Trained technician only) Replace the affected microprocessor.
7. Manually re-enable all affected DIMMs. Update firmware version to the latest level and
reconnect to server to the power source and restart the server.
8. (Trained Service technician only) Replace the affected microprocessor.
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0138
User Response
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the problem follows the DIMM, replace the failing DIMM.
4. (Trained technician only) Remove the affected microprocessor and check the microprocessor
socket pins for any damaged pins. If a damage is found, replace the system board.
5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM
connector. If the connector contains any foreign material or is damaged, replace the system
board.
6. (Trained technician only) Replace the affected microprocessor.
7. Manually re-enable all affected DIMMs. Update firmware version to the latest level and
reconnect to server to the power source and restart the server.
8. (Trained Service technician only) Replace the affected microprocessor.
Severity
Error
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the problem follows the DIMM, replace the failing DIMM.
4. (Trained technician only) Remove the affected microprocessor and check the microprocessor
socket pins for any damaged pins. If a damage is found, replace the system board.
5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM
connector. If the connector contains any foreign material or is damaged, replace the system
board.
6. (Trained technician only) Replace the affected microprocessor.
7. Manually re-enable all affected DIMMs. Update firmware version to the latest level and
reconnect to server to the power source and restart the server.
8. (Trained Service technician only) Replace the affected microprocessor.
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0164
User Response
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0164
User Response
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0164
User Response
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0164
User Response
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0164
User Response
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0164
User Response
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0164
User Response
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0164
User Response
Severity
Error
Serviceable
Yes
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0164
User Response
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0164
User Response
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0164
User Response
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0164
User Response
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0164
User Response
Severity
Error
Serviceable
Yes
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0164
User Response
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0164
User Response
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0164
User Response
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0164
User Response
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0164
User Response
Severity
Error
Serviceable
Yes
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0164
User Response
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0164
User Response
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
System - Boot failure
SNMP Trap ID
25
1. Make sure the server meets the minimum configuration to start (see Power-supply LEDs).
2. Update the server firmware on the primary page. Important: Some cluster solutions require
specific code levels or coordinated code updates. If the device is part of a cluster solution, verify
that the latest level of code is supported for the cluster solution before you update the code.
3. (Trained technician only) Replace the system board.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0224
User Response
Severity
Error
Serviceable
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0266
User Response
If the specified sensor is front USB connector, reset the front USB cable on the system board. If
the specified sensor is front video connector, reset the front video cable in the system board. If the
specified sensor is PwrPaddle cable, complete the following steps until problem is solved:
1. Reseat the power paddle cable on the system board.
2. Replace the power paddle cable.
3. (Trained technician only) Replace the supercap n. (n = supercap number)
4. (Trained technician only) Replace the system board.
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0266
User Response
If the specified sensor is front USB connector, reset the front USB cable on the system board. If
the specified sensor is front video connector, reset the front video cable in the system board. If the
specified sensor is PwrPaddle cable, complete the following steps until problem is solved:
1. Reseat the power paddle cable on the system board.
2. Replace the power paddle cable.
3. (Trained technician only) Replace the supercap n. (n = supercap number)
4. (Trained technician only) Replace the system board.
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Other
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0266
User Response
If the specified sensor is front USB connector, reset the front USB cable on the system board. If
the specified sensor is front video connector, reset the front video cable in the system board. If the
specified sensor is PwrPaddle cable, complete the following steps until problem is solved:
1. Reseat the power paddle cable on the system board.
2. Replace the power paddle cable.
3. (Trained technician only) Replace the supercap n. (n = supercap number)
4. (Trained technician only) Replace the system board.
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0266
User Response
If the specified sensor is front USB connector, reset the front USB cable on the system board. If
the specified sensor is front video connector, reset the front video cable in the system board. If the
specified sensor is PwrPaddle cable, complete the following steps until problem is solved:
1. Reseat the power paddle cable on the system board.
2. Replace the power paddle cable.
3. (Trained technician only) Replace the supercap n. (n = supercap number)
4. (Trained technician only) Replace the system board.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0392
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0392
User Response
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0392
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0392
User Response
No action; information only.
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - CPU
SNMP Trap ID
40
CIM Information
Prefix: PLAT ID: 0044
User Response
1. Make sure that the latest levels of firmware and device drivers are installed for all adapters and
standard devices, such as Ethernet, SCSI, and SAS. Important: Some cluster solutions require
specific code levels or coordinated code updates. If the device is part of a cluster solution, verify
that the latest level of code is supported for the cluster solution before you update the code.
2. Update the firmware (UEFI and IMM) to the latest level (Updating the firmware).
3. Run the DSA program.
4. Reseat the adapter.
5. Replace the adapter.
6. (Trained technician only) Replace microprocessor n.
7. (Trained technician only) Replace the system board. (n = microprocessor number)
Severity
Error
Serviceable
Yes
Automatically notify support
1. Make sure that the latest levels of firmware and device drivers are installed for all adapters and
standard devices, such as Ethernet, SCSI, and SAS. Important: Some cluster solutions require
specific code levels or coordinated code updates. If the device is part of a cluster solution, verify
that the latest level of code is supported for the cluster solution before you update the code.
2. Update the firmware (UEFI and IMM) to the latest level (Updating the firmware).
3. Run the DSA program.
4. Reseat the adapter.
5. Replace the adapter.
6. (Trained technician only) Replace microprocessor n.
7. (Trained technician only) Replace the system board. (n = microprocessor number)
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - CPU
SNMP Trap ID
40
CIM Information
Prefix: PLAT ID: 0044
User Response
1. Make sure that the latest levels of firmware and device drivers are installed for all adapters and
standard devices, such as Ethernet, SCSI, and SAS. Important: Some cluster solutions require
specific code levels or coordinated code updates. If the device is part of a cluster solution, verify
that the latest level of code is supported for the cluster solution before you update the code.
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
System - Predicted Failure
SNMP Trap ID
27
CIM Information
Prefix: PLAT ID: 0168
User Response
Severity
Warning
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
System - Predicted Failure
SNMP Trap ID
27
CIM Information
Prefix: PLAT ID: 0168
User Response
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
System - Predicted Failure
SNMP Trap ID
27
CIM Information
Prefix: PLAT ID: 0168
User Response
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
System - Predicted Failure
SNMP Trap ID
27
CIM Information
Prefix: PLAT ID: 0168
User Response
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
System - Predicted Failure
SNMP Trap ID
27
CIM Information
Prefix: PLAT ID: 0168
User Response
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
System - Predicted Failure
SNMP Trap ID
27
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
System - Predicted Failure
SNMP Trap ID
27
CIM Information
Prefix: PLAT ID: 0168
User Response
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
System - Predicted Failure
SNMP Trap ID
27
CIM Information
Prefix: PLAT ID: 0168
User Response
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
System - Predicted Failure
SNMP Trap ID
27
CIM Information
Prefix: PLAT ID: 0168
User Response
Severity
Warning
Serviceable
Yes
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
System - Predicted Failure
SNMP Trap ID
27
CIM Information
Prefix: PLAT ID: 0168
User Response
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
System - Predicted Failure
SNMP Trap ID
27
CIM Information
Prefix: PLAT ID: 0168
User Response
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
System - Predicted Failure
SNMP Trap ID
27
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
System - Predicted Failure
SNMP Trap ID
27
CIM Information
Prefix: PLAT ID: 0168
User Response
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
System - Predicted Failure
SNMP Trap ID
27
CIM Information
Prefix: PLAT ID: 0168
User Response
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
System - Predicted Failure
SNMP Trap ID
27
CIM Information
Prefix: PLAT ID: 0168
User Response
Severity
Warning
Serviceable
Yes
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
System - Predicted Failure
SNMP Trap ID
27
CIM Information
Prefix: PLAT ID: 0168
User Response
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
System - Predicted Failure
SNMP Trap ID
27
CIM Information
Prefix: PLAT ID: 0168
User Response
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
System - Predicted Failure
SNMP Trap ID
27
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
System - Predicted Failure
SNMP Trap ID
27
CIM Information
Prefix: PLAT ID: 0168
User Response
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
System - Predicted Failure
SNMP Trap ID
27
CIM Information
Prefix: PLAT ID: 0168
User Response
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
System - Predicted Failure
SNMP Trap ID
27
CIM Information
Prefix: PLAT ID: 0168
User Response
Severity
Warning
Serviceable
Yes
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
System - Predicted Failure
SNMP Trap ID
27
CIM Information
Prefix: PLAT ID: 0168
User Response
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
System - Predicted Failure
SNMP Trap ID
27
CIM Information
Prefix: PLAT ID: 0168
User Response
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
System - Predicted Failure
SNMP Trap ID
27
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0372
User Response
No action; information only.
Severity
Info
Serviceable
No
CIM Information
Prefix: PLAT ID: 0100
User Response
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0100
User Response
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0136
User Response
Note: Each time you install or remove a DIMM, you must disconnect the server from the power
source; then, wait 10 seconds before restarting the server.
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0136
User Response
Note: Each time you install or remove a DIMM, you must disconnect the server from the power
source; then, wait 10 seconds before restarting the server.
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the error still occurs on the same DIMM, replace the affected DIMM.
4. (Trained service technician only) Remove the affected microprocessor and check the
microprocessor socket pins for any damaged pins. If a damage is found, replace the system
board.
5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM
connector. If the connector contains any foreign material or is damaged, replace the system
board.
6. (Trained technician only) Replace the affected microprocessor.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0136
User Response
Note: Each time you install or remove a DIMM, you must disconnect the server from the power
source; then, wait 10 seconds before restarting the server.
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the error still occurs on the same DIMM, replace the affected DIMM.
4. (Trained service technician only) Remove the affected microprocessor and check the
microprocessor socket pins for any damaged pins. If a damage is found, replace the system
board.
5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM
connector. If the connector contains any foreign material or is damaged, replace the system
board.
6. (Trained technician only) Replace the affected microprocessor.
Severity
Error
Serviceable
Yes
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0136
User Response
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0136
User Response
Note: Each time you install or remove a DIMM, you must disconnect the server from the power
source; then, wait 10 seconds before restarting the server.
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the error still occurs on the same DIMM, replace the affected DIMM.
4. (Trained service technician only) Remove the affected microprocessor and check the
microprocessor socket pins for any damaged pins. If a damage is found, replace the system
board.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0136
User Response
Note: Each time you install or remove a DIMM, you must disconnect the server from the power
source; then, wait 10 seconds before restarting the server.
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the error still occurs on the same DIMM, replace the affected DIMM.
4. (Trained service technician only) Remove the affected microprocessor and check the
microprocessor socket pins for any damaged pins. If a damage is found, replace the system
board.
5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM
connector. If the connector contains any foreign material or is damaged, replace the system
board.
6. (Trained technician only) Replace the affected microprocessor.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0136
User Response
Note: Each time you install or remove a DIMM, you must disconnect the server from the power
source; then, wait 10 seconds before restarting the server.
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0136
User Response
Note: Each time you install or remove a DIMM, you must disconnect the server from the power
source; then, wait 10 seconds before restarting the server.
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the error still occurs on the same DIMM, replace the affected DIMM.
4. (Trained service technician only) Remove the affected microprocessor and check the
microprocessor socket pins for any damaged pins. If a damage is found, replace the system
board.
5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM
connector. If the connector contains any foreign material or is damaged, replace the system
board.
6. (Trained technician only) Replace the affected microprocessor.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0136
User Response
Note: Each time you install or remove a DIMM, you must disconnect the server from the power
source; then, wait 10 seconds before restarting the server.
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the error still occurs on the same DIMM, replace the affected DIMM.
4. (Trained service technician only) Remove the affected microprocessor and check the
microprocessor socket pins for any damaged pins. If a damage is found, replace the system
board.
5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM
connector. If the connector contains any foreign material or is damaged, replace the system
board.
6. (Trained technician only) Replace the affected microprocessor.
Severity
Error
Serviceable
Yes
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0136
User Response
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0136
User Response
Note: Each time you install or remove a DIMM, you must disconnect the server from the power
source; then, wait 10 seconds before restarting the server.
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the error still occurs on the same DIMM, replace the affected DIMM.
4. (Trained service technician only) Remove the affected microprocessor and check the
microprocessor socket pins for any damaged pins. If a damage is found, replace the system
board.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0136
User Response
Note: Each time you install or remove a DIMM, you must disconnect the server from the power
source; then, wait 10 seconds before restarting the server.
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the error still occurs on the same DIMM, replace the affected DIMM.
4. (Trained service technician only) Remove the affected microprocessor and check the
microprocessor socket pins for any damaged pins. If a damage is found, replace the system
board.
5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM
connector. If the connector contains any foreign material or is damaged, replace the system
board.
6. (Trained technician only) Replace the affected microprocessor.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0136
User Response
Note: Each time you install or remove a DIMM, you must disconnect the server from the power
source; then, wait 10 seconds before restarting the server.
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0136
User Response
Note: Each time you install or remove a DIMM, you must disconnect the server from the power
source; then, wait 10 seconds before restarting the server.
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the error still occurs on the same DIMM, replace the affected DIMM.
4. (Trained service technician only) Remove the affected microprocessor and check the
microprocessor socket pins for any damaged pins. If a damage is found, replace the system
board.
5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM
connector. If the connector contains any foreign material or is damaged, replace the system
board.
6. (Trained technician only) Replace the affected microprocessor.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0136
User Response
Note: Each time you install or remove a DIMM, you must disconnect the server from the power
source; then, wait 10 seconds before restarting the server.
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the error still occurs on the same DIMM, replace the affected DIMM.
4. (Trained service technician only) Remove the affected microprocessor and check the
microprocessor socket pins for any damaged pins. If a damage is found, replace the system
board.
5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM
connector. If the connector contains any foreign material or is damaged, replace the system
board.
6. (Trained technician only) Replace the affected microprocessor.
Severity
Error
Serviceable
Yes
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0228
User Response
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0374
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0131
User Response
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0131
User Response
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0131
User Response
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0131
User Response
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0131
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0131
User Response
CIM Information
Prefix: PLAT ID: 0131
User Response
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0131
User Response
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0131
User Response
Severity
CIM Information
Prefix: PLAT ID: 0131
User Response
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0131
User Response
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0131
User Response
Severity
Info
CIM Information
Prefix: PLAT ID: 0131
User Response
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0131
User Response
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0131
User Response
Severity
Info
Serviceable
No
Automatically notify support
CIM Information
Prefix: PLAT ID: 0131
User Response
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0131
User Response
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0131
User Response
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
CIM Information
Prefix: PLAT ID: 0131
User Response
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0131
User Response
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0131
User Response
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0131
User Response
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0232
User Response
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - CPU
SNMP Trap ID
40
1. Check the CPU LED. See more information about the CPU LED in Light path diagnostics.
2. Check for a server firmware update. Important: Some cluster solutions require specific code
levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest
level of code is supported for the cluster solution before you update the code.
3. Make sure that the installed microprocessors are compatible with each other.
4. (Trained technician only) Reseat microprocessor n.
5. (Trained technician only) Replace microprocessor n. (n = microprocessor number)
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - CPU
SNMP Trap ID
40
CIM Information
Prefix: PLAT ID: 0062
User Response
1. Check the CPU LED. See more information about the CPU LED in Light path diagnostics.
2. Check for a server firmware update. Important: Some cluster solutions require specific code
levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest
level of code is supported for the cluster solution before you update the code.
3. Make sure that the installed microprocessors are compatible with each other.
4. (Trained technician only) Reseat microprocessor n.
5. (Trained technician only) Replace microprocessor n. (n = microprocessor number)
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - CPU
SNMP Trap ID
40
CIM Information
Prefix: PLAT ID: 0062
User Response
1. Check the CPU LED. See more information about the CPU LED in Light path diagnostics.
2. Check for a server firmware update. Important: Some cluster solutions require specific code
levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest
level of code is supported for the cluster solution before you update the code.
3. Make sure that the installed microprocessors are compatible with each other.
4. (Trained technician only) Reseat microprocessor n.
5. (Trained technician only) Replace microprocessor n. (n = microprocessor number)
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Warning - Memory
SNMP Trap ID
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the error still occurs on the same DIMM, replace the affected DIMM.
4. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM
connector. If the connector contains any foreign material or is damaged, replace the system
board.
5. (Trained technician only) Remove the affected microprocessor and check the microprocessor
socket pins for any damaged pins. If a damage is found, replace the system board.
6. (Trained technician only) Replace the affected microprocessor.
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Warning - Memory
SNMP Trap ID
43
CIM Information
Prefix: PLAT ID: 0144
User Response
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the error still occurs on the same DIMM, replace the affected DIMM.
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Warning - Memory
SNMP Trap ID
43
CIM Information
Prefix: PLAT ID: 0144
User Response
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the error still occurs on the same DIMM, replace the affected DIMM.
4. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM
connector. If the connector contains any foreign material or is damaged, replace the system
board.
5. (Trained technician only) Remove the affected microprocessor and check the microprocessor
socket pins for any damaged pins. If a damage is found, replace the system board.
6. (Trained technician only) Replace the affected microprocessor.
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Warning - Memory
SNMP Trap ID
43
CIM Information
Prefix: PLAT ID: 0144
User Response
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the error still occurs on the same DIMM, replace the affected DIMM.
4. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM
connector. If the connector contains any foreign material or is damaged, replace the system
board.
5. (Trained technician only) Remove the affected microprocessor and check the microprocessor
socket pins for any damaged pins. If a damage is found, replace the system board.
6. (Trained technician only) Replace the affected microprocessor.
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Warning - Memory
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the error still occurs on the same DIMM, replace the affected DIMM.
4. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM
connector. If the connector contains any foreign material or is damaged, replace the system
board.
5. (Trained technician only) Remove the affected microprocessor and check the microprocessor
socket pins for any damaged pins. If a damage is found, replace the system board.
6. (Trained technician only) Replace the affected microprocessor.
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Warning - Memory
SNMP Trap ID
43
CIM Information
Prefix: PLAT ID: 0144
User Response
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the error still occurs on the same DIMM, replace the affected DIMM.
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Warning - Memory
SNMP Trap ID
43
CIM Information
Prefix: PLAT ID: 0144
User Response
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the error still occurs on the same DIMM, replace the affected DIMM.
4. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM
connector. If the connector contains any foreign material or is damaged, replace the system
board.
5. (Trained technician only) Remove the affected microprocessor and check the microprocessor
socket pins for any damaged pins. If a damage is found, replace the system board.
6. (Trained technician only) Replace the affected microprocessor.
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Warning - Memory
SNMP Trap ID
43
CIM Information
Prefix: PLAT ID: 0144
User Response
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the error still occurs on the same DIMM, replace the affected DIMM.
4. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM
connector. If the connector contains any foreign material or is damaged, replace the system
board.
5. (Trained technician only) Remove the affected microprocessor and check the microprocessor
socket pins for any damaged pins. If a damage is found, replace the system board.
6. (Trained technician only) Replace the affected microprocessor.
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Warning - Memory
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the error still occurs on the same DIMM, replace the affected DIMM.
4. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM
connector. If the connector contains any foreign material or is damaged, replace the system
board.
5. (Trained technician only) Remove the affected microprocessor and check the microprocessor
socket pins for any damaged pins. If a damage is found, replace the system board.
6. (Trained technician only) Replace the affected microprocessor.
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Warning - Memory
SNMP Trap ID
43
CIM Information
Prefix: PLAT ID: 0144
User Response
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the error still occurs on the same DIMM, replace the affected DIMM.
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Warning - Memory
SNMP Trap ID
43
CIM Information
Prefix: PLAT ID: 0144
User Response
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the error still occurs on the same DIMM, replace the affected DIMM.
4. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM
connector. If the connector contains any foreign material or is damaged, replace the system
board.
5. (Trained technician only) Remove the affected microprocessor and check the microprocessor
socket pins for any damaged pins. If a damage is found, replace the system board.
6. (Trained technician only) Replace the affected microprocessor.
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Warning - Memory
SNMP Trap ID
43
CIM Information
Prefix: PLAT ID: 0144
User Response
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the error still occurs on the same DIMM, replace the affected DIMM.
4. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM
connector. If the connector contains any foreign material or is damaged, replace the system
board.
5. (Trained technician only) Remove the affected microprocessor and check the microprocessor
socket pins for any damaged pins. If a damage is found, replace the system board.
6. (Trained technician only) Replace the affected microprocessor.
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Warning - Memory
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the error still occurs on the same DIMM, replace the affected DIMM.
4. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM
connector. If the connector contains any foreign material or is damaged, replace the system
board.
5. (Trained technician only) Remove the affected microprocessor and check the microprocessor
socket pins for any damaged pins. If a damage is found, replace the system board.
6. (Trained technician only) Replace the affected microprocessor.
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Warning - Memory
SNMP Trap ID
43
CIM Information
Prefix: PLAT ID: 0144
User Response
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the error still occurs on the same DIMM, replace the affected DIMM.
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Warning - Memory
SNMP Trap ID
43
CIM Information
Prefix: PLAT ID: 0144
User Response
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the error still occurs on the same DIMM, replace the affected DIMM.
4. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM
connector. If the connector contains any foreign material or is damaged, replace the system
board.
5. (Trained technician only) Remove the affected microprocessor and check the microprocessor
socket pins for any damaged pins. If a damage is found, replace the system board.
6. (Trained technician only) Replace the affected microprocessor.
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Warning - Memory
SNMP Trap ID
43
CIM Information
Prefix: PLAT ID: 0144
User Response
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the error still occurs on the same DIMM, replace the affected DIMM.
4. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM
connector. If the connector contains any foreign material or is damaged, replace the system
board.
5. (Trained technician only) Remove the affected microprocessor and check the microprocessor
socket pins for any damaged pins. If a damage is found, replace the system board.
6. (Trained technician only) Replace the affected microprocessor.
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Warning - Memory
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the error still occurs on the same DIMM, replace the affected DIMM.
4. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM
connector. If the connector contains any foreign material or is damaged, replace the system
board.
5. (Trained technician only) Remove the affected microprocessor and check the microprocessor
socket pins for any damaged pins. If a damage is found, replace the system board.
6. (Trained technician only) Replace the affected microprocessor.
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Warning - Memory
SNMP Trap ID
43
CIM Information
Prefix: PLAT ID: 0144
User Response
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the error still occurs on the same DIMM, replace the affected DIMM.
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Warning - Memory
SNMP Trap ID
43
CIM Information
Prefix: PLAT ID: 0144
User Response
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the error still occurs on the same DIMM, replace the affected DIMM.
4. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM
connector. If the connector contains any foreign material or is damaged, replace the system
board.
5. (Trained technician only) Remove the affected microprocessor and check the microprocessor
socket pins for any damaged pins. If a damage is found, replace the system board.
6. (Trained technician only) Replace the affected microprocessor.
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Warning - Memory
SNMP Trap ID
43
CIM Information
Prefix: PLAT ID: 0144
User Response
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the error still occurs on the same DIMM, replace the affected DIMM.
4. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM
connector. If the connector contains any foreign material or is damaged, replace the system
board.
5. (Trained technician only) Remove the affected microprocessor and check the microprocessor
socket pins for any damaged pins. If a damage is found, replace the system board.
6. (Trained technician only) Replace the affected microprocessor.
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Warning - Memory
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the error still occurs on the same DIMM, replace the affected DIMM.
4. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM
connector. If the connector contains any foreign material or is damaged, replace the system
board.
5. (Trained technician only) Remove the affected microprocessor and check the microprocessor
socket pins for any damaged pins. If a damage is found, replace the system board.
6. (Trained technician only) Replace the affected microprocessor.
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Warning - Memory
SNMP Trap ID
43
CIM Information
Prefix: PLAT ID: 0144
User Response
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the error still occurs on the same DIMM, replace the affected DIMM.
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Warning - Memory
SNMP Trap ID
43
CIM Information
Prefix: PLAT ID: 0144
User Response
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the error still occurs on the same DIMM, replace the affected DIMM.
4. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM
connector. If the connector contains any foreign material or is damaged, replace the system
board.
5. (Trained technician only) Remove the affected microprocessor and check the microprocessor
socket pins for any damaged pins. If a damage is found, replace the system board.
6. (Trained technician only) Replace the affected microprocessor.
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Warning - Memory
SNMP Trap ID
43
CIM Information
Prefix: PLAT ID: 0144
User Response
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the error still occurs on the same DIMM, replace the affected DIMM.
4. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM
connector. If the connector contains any foreign material or is damaged, replace the system
board.
5. (Trained technician only) Remove the affected microprocessor and check the microprocessor
socket pins for any damaged pins. If a damage is found, replace the system board.
6. (Trained technician only) Replace the affected microprocessor.
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Warning - Memory
1. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
3. If the error still occurs on the same DIMM, replace the affected DIMM.
4. (Trained technician only) Remove the affected microprocessor and check the microprocessor
socket pins for any damaged pins. If a damage is found, replace the system board.
5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM
connector. If the connector contains any foreign material or is damaged, replace the system
board.
6. (Trained technician only) Replace the affected microprocessor. One of the DIMMs :
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0174
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Check backplane cable connection.
5. Replace the RAID adapter.
6. Replace the hard disk drive that is indicated by a lit status LED.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0174
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Check backplane cable connection.
5. Replace the RAID adapter.
6. Replace the hard disk drive that is indicated by a lit status LED.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Check backplane cable connection.
5. Replace the RAID adapter.
6. Replace the hard disk drive that is indicated by a lit status LED.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0174
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Check backplane cable connection.
5. Replace the RAID adapter.
6. Replace the hard disk drive that is indicated by a lit status LED.
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Check backplane cable connection.
5. Replace the RAID adapter.
6. Replace the hard disk drive that is indicated by a lit status LED.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0174
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0174
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Check backplane cable connection.
5. Replace the RAID adapter.
6. Replace the hard disk drive that is indicated by a lit status LED.
Severity
Error
Serviceable
Yes
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Check backplane cable connection.
5. Replace the RAID adapter.
6. Replace the hard disk drive that is indicated by a lit status LED.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0174
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Check backplane cable connection.
5. Replace the RAID adapter.
6. Replace the hard disk drive that is indicated by a lit status LED.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0174
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Check backplane cable connection.
5. Replace the RAID adapter.
6. Replace the hard disk drive that is indicated by a lit status LED.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Check backplane cable connection.
5. Replace the RAID adapter.
6. Replace the hard disk drive that is indicated by a lit status LED.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0174
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Check backplane cable connection.
5. Replace the RAID adapter.
6. Replace the hard disk drive that is indicated by a lit status LED.
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Check backplane cable connection.
5. Replace the RAID adapter.
6. Replace the hard disk drive that is indicated by a lit status LED.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0174
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0174
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Check backplane cable connection.
5. Replace the RAID adapter.
6. Replace the hard disk drive that is indicated by a lit status LED.
Severity
Error
Serviceable
Yes
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Check backplane cable connection.
5. Replace the RAID adapter.
6. Replace the hard disk drive that is indicated by a lit status LED.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0174
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Check backplane cable connection.
5. Replace the RAID adapter.
6. Replace the hard disk drive that is indicated by a lit status LED.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0174
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Check backplane cable connection.
5. Replace the RAID adapter.
6. Replace the hard disk drive that is indicated by a lit status LED.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Check backplane cable connection.
5. Replace the RAID adapter.
6. Replace the hard disk drive that is indicated by a lit status LED.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0174
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Check backplane cable connection.
5. Replace the RAID adapter.
6. Replace the hard disk drive that is indicated by a lit status LED.
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Check backplane cable connection.
5. Replace the RAID adapter.
6. Replace the hard disk drive that is indicated by a lit status LED.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0174
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0174
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Check backplane cable connection.
5. Replace the RAID adapter.
6. Replace the hard disk drive that is indicated by a lit status LED.
Severity
Error
Serviceable
Yes
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Check backplane cable connection.
5. Replace the RAID adapter.
6. Replace the hard disk drive that is indicated by a lit status LED.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0174
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Check backplane cable connection.
5. Replace the RAID adapter.
6. Replace the hard disk drive that is indicated by a lit status LED.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0174
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Check backplane cable connection.
5. Replace the RAID adapter.
6. Replace the hard disk drive that is indicated by a lit status LED.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Check backplane cable connection.
5. Replace the RAID adapter.
6. Replace the hard disk drive that is indicated by a lit status LED.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0174
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Check backplane cable connection.
5. Replace the RAID adapter.
6. Replace the hard disk drive that is indicated by a lit status LED.
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Check backplane cable connection.
5. Replace the RAID adapter.
6. Replace the hard disk drive that is indicated by a lit status LED.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0174
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0174
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Check backplane cable connection.
5. Replace the RAID adapter.
6. Replace the hard disk drive that is indicated by a lit status LED.
Severity
Error
Serviceable
Yes
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Check backplane cable connection.
5. Replace the RAID adapter.
6. Replace the hard disk drive that is indicated by a lit status LED.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0234
User Response
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0446
User Response
1. Make sure the server meets the minimum configuration to start (see Power-supply LEDs).
2. Recover the server firmware from the backup page by restarting the server.
3. Update the server firmware to the latest level (see Updating the firmware). Important: Some
cluster solutions require specific code levels or coordinated code updates. If the device is part
of a cluster solution, verify that the latest level of code is supported for the cluster solution
before you update the code.
4. Remove components one at a time, restarting the server each time, to see if the problem
goes away.
5. If the problem remains, (trained service technician) replace the system board.
1. Make sure that the installed microprocessors are compatible with each other (see Installing a
microprocessor and heat sink for information about microprocessor requirements).
2. Update the server firmware to the latest level (see Updating the firmware).
3. (Trained technician only) Replace the incompatible microprocessor.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - CPU
SNMP Trap ID
40
CIM Information
Prefix: PLAT ID: 0816
User Response
1. Make sure that the installed microprocessors are compatible with each other (see Installing a
microprocessor and heat sink for information about microprocessor requirements).
2. Update the server firmware to the latest level (see Updating the firmware).
3. (Trained technician only) Replace the incompatible microprocessor.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - CPU
SNMP Trap ID
40
CIM Information
Prefix: PLAT ID: 0816
User Response
1. Make sure that the installed microprocessors are compatible with each other (see Installing a
microprocessor and heat sink for information about microprocessor requirements).
2. Update the server firmware to the latest level (see Updating the firmware).
3. (Trained technician only) Replace the incompatible microprocessor. One of the CPUs :
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Power
SNMP Trap ID
4
CIM Information
1. Make sure that the power supplies installed are with the same rating or wattage.
2. Reinstall the power supplies with the same rating or wattage.
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0176
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Replace the RAID adapter.
5. Replace the hard disk drive that is indicated by a lit status LED.
Severity
Error
Serviceable
Yes
Automatically notify support
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Replace the RAID adapter.
5. Replace the hard disk drive that is indicated by a lit status LED.
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0176
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Replace the RAID adapter.
5. Replace the hard disk drive that is indicated by a lit status LED.
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0176
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Replace the RAID adapter.
5. Replace the hard disk drive that is indicated by a lit status LED.
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0176
User Response
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0176
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Replace the RAID adapter.
5. Replace the hard disk drive that is indicated by a lit status LED.
Severity
Error
Serviceable
Yes
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Replace the RAID adapter.
5. Replace the hard disk drive that is indicated by a lit status LED.
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0176
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Replace the RAID adapter.
5. Replace the hard disk drive that is indicated by a lit status LED.
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0176
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Replace the RAID adapter.
5. Replace the hard disk drive that is indicated by a lit status LED.
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0176
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Replace the RAID adapter.
5. Replace the hard disk drive that is indicated by a lit status LED.
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0176
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Replace the RAID adapter.
5. Replace the hard disk drive that is indicated by a lit status LED.
Severity
Error
Serviceable
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Replace the RAID adapter.
5. Replace the hard disk drive that is indicated by a lit status LED.
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0176
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Replace the RAID adapter.
5. Replace the hard disk drive that is indicated by a lit status LED.
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0176
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Replace the RAID adapter.
5. Replace the hard disk drive that is indicated by a lit status LED.
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Replace the RAID adapter.
5. Replace the hard disk drive that is indicated by a lit status LED.
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0176
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Replace the RAID adapter.
5. Replace the hard disk drive that is indicated by a lit status LED.
Severity
Error
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Replace the RAID adapter.
5. Replace the hard disk drive that is indicated by a lit status LED.
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0176
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Replace the RAID adapter.
5. Replace the hard disk drive that is indicated by a lit status LED.
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0176
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Replace the RAID adapter.
5. Replace the hard disk drive that is indicated by a lit status LED.
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Replace the RAID adapter.
5. Replace the hard disk drive that is indicated by a lit status LED.
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0176
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Replace the RAID adapter.
5. Replace the hard disk drive that is indicated by a lit status LED.
Severity
Error
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Replace the RAID adapter.
5. Replace the hard disk drive that is indicated by a lit status LED.
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0176
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Replace the RAID adapter.
5. Replace the hard disk drive that is indicated by a lit status LED.
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0176
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Replace the RAID adapter.
5. Replace the hard disk drive that is indicated by a lit status LED.
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Replace the RAID adapter.
5. Replace the hard disk drive that is indicated by a lit status LED.
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0176
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Replace the RAID adapter.
5. Replace the hard disk drive that is indicated by a lit status LED.
Severity
Error
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Replace the RAID adapter.
5. Replace the hard disk drive that is indicated by a lit status LED.
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0176
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Replace the RAID adapter.
5. Replace the hard disk drive that is indicated by a lit status LED.
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0176
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Replace the RAID adapter.
5. Replace the hard disk drive that is indicated by a lit status LED.
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Replace the RAID adapter.
5. Replace the hard disk drive that is indicated by a lit status LED.
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0176
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Replace the RAID adapter.
5. Replace the hard disk drive that is indicated by a lit status LED.
Severity
Error
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Replace the RAID adapter.
5. Replace the hard disk drive that is indicated by a lit status LED.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0126
User Response
Make sure that DIMMs are installed in the correct sequence and have the same size, type, speed,
and technology.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0126
User Response
Make sure that DIMMs are installed in the correct sequence and have the same size, type, speed,
and technology.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0126
User Response
Make sure that DIMMs are installed in the correct sequence and have the same size, type, speed,
and technology.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0126
User Response
Make sure that DIMMs are installed in the correct sequence and have the same size, type, speed,
and technology.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0126
User Response
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0126
User Response
Make sure that DIMMs are installed in the correct sequence and have the same size, type, speed,
and technology.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0126
User Response
Make sure that DIMMs are installed in the correct sequence and have the same size, type, speed,
and technology.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0126
User Response
Make sure that DIMMs are installed in the correct sequence and have the same size, type, speed,
and technology.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0126
User Response
Make sure that DIMMs are installed in the correct sequence and have the same size, type, speed,
and technology.
Severity
Error
Serviceable
Yes
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0126
User Response
Make sure that DIMMs are installed in the correct sequence and have the same size, type, speed,
and technology.
Severity
Error
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0126
User Response
Make sure that DIMMs are installed in the correct sequence and have the same size, type, speed,
and technology.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0126
User Response
Make sure that DIMMs are installed in the correct sequence and have the same size, type, speed,
and technology.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0126
User Response
Make sure that DIMMs are installed in the correct sequence and have the same size, type, speed,
and technology.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0126
User Response
Make sure that DIMMs are installed in the correct sequence and have the same size, type, speed,
and technology.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0126
User Response
Make sure that DIMMs are installed in the correct sequence and have the same size, type, speed,
and technology.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0126
User Response
Make sure that DIMMs are installed in the correct sequence and have the same size, type, speed,
and technology.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0126
User Response
Make sure that DIMMs are installed in the correct sequence and have the same size, type, speed,
and technology.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0126
User Response
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0126
User Response
Make sure that DIMMs are installed in the correct sequence and have the same size, type, speed,
and technology. One of the DIMMs :
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0178
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0178
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
CIM Information
Prefix: PLAT ID: 0178
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0178
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
CIM Information
Prefix: PLAT ID: 0178
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0178
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
CIM Information
Prefix: PLAT ID: 0178
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0178
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
CIM Information
Prefix: PLAT ID: 0178
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0178
User Response
No action; information only.
Severity
Info
Serviceable
No
CIM Information
Prefix: PLAT ID: 0178
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0178
User Response
No action; information only.
Severity
Info
Serviceable
CIM Information
Prefix: PLAT ID: 0178
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0178
User Response
No action; information only.
Severity
Info
CIM Information
Prefix: PLAT ID: 0178
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0178
User Response
No action; information only.
Severity
CIM Information
Prefix: PLAT ID: 0178
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0178
User Response
No action; information only.
CIM Information
Prefix: PLAT ID: 0178
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0178
User Response
No action; information only.
CIM Information
Prefix: PLAT ID: 0178
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0178
User Response
No action; information only.
CIM Information
Prefix: PLAT ID: 0178
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0178
User Response
No action; information only.
CIM Information
Prefix: PLAT ID: 0178
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0178
User Response
No action; information only.
CIM Information
Prefix: PLAT ID: 0178
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0178
User Response
No action; information only.
CIM Information
Prefix: PLAT ID: 0178
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0178
User Response
No action; information only.
CIM Information
Prefix: PLAT ID: 0450
User Response
No action; information only. ROM Recovery :
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0061
User Response
1. Make sure that the installed microprocessors are compatible with each other (see Installing a
microprocessor and heat sink for information about microprocessor requirements).
2. Update the server firmware to the latest level (see Updating the firmware).
3. (Trained technician only) Replace the incompatible microprocessor.
CIM Information
Prefix: PLAT ID: 0061
User Response
1. Make sure that the installed microprocessors are compatible with each other (see Installing a
microprocessor and heat sink for information about microprocessor requirements).
2. Update the server firmware to the latest level (see Updating the firmware).
3. (Trained technician only) Replace the incompatible microprocessor.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0061
User Response
1. Make sure that the installed microprocessors are compatible with each other (see Installing a
microprocessor and heat sink for information about microprocessor requirements).
2. Update the server firmware to the latest level (see Updating the firmware).
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0240
User Response
Severity
Error
Serviceable
Yes
Automatically notify support
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0240
User Response
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0376
User Response
No action; information only.
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
22
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
22
CIM Information
Prefix: PLAT ID: 0142
User Response
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
22
CIM Information
Prefix: PLAT ID: 0142
User Response
Severity
Warning
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
22
CIM Information
Prefix: PLAT ID: 0142
User Response
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
22
CIM Information
Prefix: PLAT ID: 0142
User Response
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
22
CIM Information
Prefix: PLAT ID: 0142
User Response
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
22
CIM Information
Prefix: PLAT ID: 0142
User Response
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
22
CIM Information
Prefix: PLAT ID: 0142
User Response
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
22
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
22
CIM Information
Prefix: PLAT ID: 0142
User Response
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
22
CIM Information
Prefix: PLAT ID: 0142
User Response
Severity
Warning
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
22
CIM Information
Prefix: PLAT ID: 0142
User Response
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
22
CIM Information
Prefix: PLAT ID: 0142
User Response
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
22
CIM Information
Prefix: PLAT ID: 0142
User Response
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
22
CIM Information
Prefix: PLAT ID: 0142
User Response
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
22
CIM Information
Prefix: PLAT ID: 0142
User Response
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
22
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
22
CIM Information
Prefix: PLAT ID: 0142
User Response
Severity
Warning
Serviceable
Yes
Automatically notify support
No
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications.(see
Features and specifications for more information)
4. Make sure that the heat sink for microprocessor n is installed correctly.
5. (Trained technician only) Replace microprocessor n. (n = microprocessor number)
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - CPU
SNMP Trap ID
42
CIM Information
Prefix: PLAT ID: 0038
User Response
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications.(see
Features and specifications for more information)
4. Make sure that the heat sink for microprocessor n is installed correctly.
5. (Trained technician only) Replace microprocessor n. (n = microprocessor number)
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0146
User Response
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications (see
Features and specifications for more information).
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications (see
Features and specifications for more information).
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0146
User Response
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications (see
Features and specifications for more information).
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications (see
Features and specifications for more information).
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0146
User Response
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0146
User Response
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications (see
Features and specifications for more information).
Severity
Error
Serviceable
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications (see
Features and specifications for more information).
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0146
User Response
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications (see
Features and specifications for more information).
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0146
User Response
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications (see
Features and specifications for more information).
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications (see
Features and specifications for more information).
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0146
User Response
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications (see
Features and specifications for more information).
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications (see
Features and specifications for more information).
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0146
User Response
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0146
User Response
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications (see
Features and specifications for more information).
Severity
Error
Serviceable
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications (see
Features and specifications for more information).
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0146
User Response
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications (see
Features and specifications for more information).
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0146
User Response
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications (see
Features and specifications for more information).
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications (see
Features and specifications for more information).
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0146
User Response
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications (see
Features and specifications for more information).
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications (see
Features and specifications for more information).
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0146
User Response
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0146
User Response
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications (see
Features and specifications for more information).
Severity
Error
Serviceable
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications (see
Features and specifications for more information).
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0146
User Response
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications (see
Features and specifications for more information).
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0244
User Response
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0244
User Response
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Warning - Voltage
SNMP Trap ID
13
CIM Information
Prefix: PLAT ID: 0477
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Voltage
SNMP Trap ID
1
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Fan Failure
SNMP Trap ID
11
CIM Information
Prefix: PLAT ID: 0481
User Response
No action; information only. Fan 1B Tach :
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Fan Failure
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Fan Failure
SNMP Trap ID
11
CIM Information
Prefix: PLAT ID: 0481
User Response
No action; information only. Fan 3B Tach :
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Warning - Temperature
SNMP Trap ID
12
CIM Information
Prefix: PLAT ID: 0491
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Warning - Temperature
SNMP Trap ID
12
CIM Information
Prefix: PLAT ID: 0491
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Warning - Temperature
SNMP Trap ID
12
CIM Information
Prefix: PLAT ID: 0491
User Response
No action; information only.
Severity
Info
Serviceable
No
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Warning - Temperature
SNMP Trap ID
12
CIM Information
Prefix: PLAT ID: 0491
User Response
No action; information only.
Severity
Info
Serviceable
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Warning - Temperature
SNMP Trap ID
12
CIM Information
Prefix: PLAT ID: 0491
User Response
No action; information only.
Severity
Info
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Warning - Temperature
SNMP Trap ID
12
CIM Information
Prefix: PLAT ID: 0491
User Response
No action; information only.
Severity
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Warning - Temperature
SNMP Trap ID
12
CIM Information
Prefix: PLAT ID: 0491
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0495
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0495
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0495
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0495
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0495
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0495
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Voltage
SNMP Trap ID
1
CIM Information
Prefix: PLAT ID: 0495
User Response
If the specified sensor is one of the following, SysBrd 3.3V, SysBrd 5V or SysBrd 12V: No action;
information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0499
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0499
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0499
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0499
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0499
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0499
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0499
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0499
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0499
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0499
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0499
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0499
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0508
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0508
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0509
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Warning - Temperature
SNMP Trap ID
12
CIM Information
Prefix: PLAT ID: 0521
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Warning - Other
SNMP Trap ID
60
CIM Information
Prefix: PLAT ID: 0521
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Warning - Other
SNMP Trap ID
60
CIM Information
Prefix: PLAT ID: 0521
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0523
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0523
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Voltage
SNMP Trap ID
1
CIM Information
Prefix: PLAT ID: 0523
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Fan Failure
SNMP Trap ID
11
CIM Information
Prefix: PLAT ID: 0523
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Fan Failure
SNMP Trap ID
11
CIM Information
Prefix: PLAT ID: 0523
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Power
SNMP Trap ID
4
CIM Information
Prefix: PLAT ID: 0523
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Power
SNMP Trap ID
4
CIM Information
Prefix: PLAT ID: 0523
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0523
User Response
No action; information only. nvDIMM Flash :
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0523
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0523
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0523
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0523
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0523
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0525
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0525
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Power
SNMP Trap ID
4
CIM Information
Prefix: PLAT ID: 0531
User Response
No action; information only. Pwr Rail B Fault : Pwr Rail C Fault : Pwr Rail D Fault : Pwr Rail E Fault :
Pwr Rail F Fault : Pwr Rail G Fault : Pwr Rail H Fault :
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Power
SNMP Trap ID
4
CIM Information
Prefix: PLAT ID: 0531
User Response
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Power
SNMP Trap ID
4
CIM Information
Prefix: PLAT ID: 0531
User Response
If the specified sensor is one of the following, PS1 12V OC Fault, PS1 12V OV Fault, PS1 12V UV
Fault or PS1 12Vaux Fault: No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Fan Failure
SNMP Trap ID
11
CIM Information
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Fan Failure
SNMP Trap ID
11
CIM Information
Prefix: PLAT ID: 0803
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0803
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Warning - Redundant Power Supply
SNMP Trap ID
10
CIM Information
Prefix: PLAT ID: 0807
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Warning - Memory
SNMP Trap ID
43
CIM Information
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Redundant Power Supply
SNMP Trap ID
9
CIM Information
Prefix: PLAT ID: 0811
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Fan Failure
SNMP Trap ID
11
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Fan Failure
SNMP Trap ID
11
CIM Information
Prefix: PLAT ID: 0811
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - CPU
SNMP Trap ID
40
CIM Information
Prefix: PLAT ID: 0043
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - CPU
SNMP Trap ID
40
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0085
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Power On
SNMP Trap ID
24
CIM Information
Prefix: PLAT ID: 0107
User Response
No action; information only.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling
the drive.
2. Replace the hard disk drive.
3. Make sure that the disk firmware and RAID controller firmware are at the latest level.
4. Check the SAS cable.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0163
User Response
1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling
the drive.
2. Replace the hard disk drive.
3. Make sure that the disk firmware and RAID controller firmware are at the latest level.
4. Check the SAS cable.
1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling
the drive.
2. Replace the hard disk drive.
3. Make sure that the disk firmware and RAID controller firmware are at the latest level.
4. Check the SAS cable.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0163
User Response
1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling
the drive.
2. Replace the hard disk drive.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0163
User Response
1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling
the drive.
2. Replace the hard disk drive.
3. Make sure that the disk firmware and RAID controller firmware are at the latest level.
4. Check the SAS cable.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling
the drive.
2. Replace the hard disk drive.
3. Make sure that the disk firmware and RAID controller firmware are at the latest level.
4. Check the SAS cable.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0163
User Response
1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling
the drive.
2. Replace the hard disk drive.
3. Make sure that the disk firmware and RAID controller firmware are at the latest level.
4. Check the SAS cable.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0163
User Response
1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling
the drive.
2. Replace the hard disk drive.
3. Make sure that the disk firmware and RAID controller firmware are at the latest level.
4. Check the SAS cable.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0163
User Response
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0163
User Response
1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling
the drive.
2. Replace the hard disk drive.
3. Make sure that the disk firmware and RAID controller firmware are at the latest level.
4. Check the SAS cable.
Severity
Error
Serviceable
Yes
1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling
the drive.
2. Replace the hard disk drive.
3. Make sure that the disk firmware and RAID controller firmware are at the latest level.
4. Check the SAS cable.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0163
User Response
1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling
the drive.
2. Replace the hard disk drive.
3. Make sure that the disk firmware and RAID controller firmware are at the latest level.
4. Check the SAS cable.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0163
User Response
1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling
the drive.
2. Replace the hard disk drive.
3. Make sure that the disk firmware and RAID controller firmware are at the latest level.
4. Check the SAS cable.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling
the drive.
2. Replace the hard disk drive.
3. Make sure that the disk firmware and RAID controller firmware are at the latest level.
4. Check the SAS cable.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0163
User Response
1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling
the drive.
2. Replace the hard disk drive.
3. Make sure that the disk firmware and RAID controller firmware are at the latest level.
4. Check the SAS cable.
Severity
1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling
the drive.
2. Replace the hard disk drive.
3. Make sure that the disk firmware and RAID controller firmware are at the latest level.
4. Check the SAS cable.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0163
User Response
1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling
the drive.
2. Replace the hard disk drive.
3. Make sure that the disk firmware and RAID controller firmware are at the latest level.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0163
User Response
1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling
the drive.
2. Replace the hard disk drive.
3. Make sure that the disk firmware and RAID controller firmware are at the latest level.
4. Check the SAS cable.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling
the drive.
2. Replace the hard disk drive.
3. Make sure that the disk firmware and RAID controller firmware are at the latest level.
4. Check the SAS cable.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0163
User Response
1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling
the drive.
2. Replace the hard disk drive.
3. Make sure that the disk firmware and RAID controller firmware are at the latest level.
4. Check the SAS cable.
1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling
the drive.
2. Replace the hard disk drive.
3. Make sure that the disk firmware and RAID controller firmware are at the latest level.
4. Check the SAS cable.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0163
User Response
1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling
the drive.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0163
User Response
1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling
the drive.
2. Replace the hard disk drive.
3. Make sure that the disk firmware and RAID controller firmware are at the latest level.
4. Check the SAS cable.
Severity
Error
Serviceable
Yes
Automatically notify support
No
1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling
the drive.
2. Replace the hard disk drive.
3. Make sure that the disk firmware and RAID controller firmware are at the latest level.
4. Check the SAS cable.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0163
User Response
1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling
the drive.
2. Replace the hard disk drive.
3. Make sure that the disk firmware and RAID controller firmware are at the latest level.
4. Check the SAS cable.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0163
User Response
1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling
the drive.
2. Replace the hard disk drive.
3. Make sure that the disk firmware and RAID controller firmware are at the latest level.
4. Check the SAS cable.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0163
User Response
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0163
User Response
1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling
the drive.
2. Replace the hard disk drive.
3. Make sure that the disk firmware and RAID controller firmware are at the latest level.
4. Check the SAS cable.
Severity
Error
Serviceable
1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling
the drive.
2. Replace the hard disk drive.
3. Make sure that the disk firmware and RAID controller firmware are at the latest level.
4. Check the SAS cable.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0163
User Response
1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling
the drive.
2. Replace the hard disk drive.
3. Make sure that the disk firmware and RAID controller firmware are at the latest level.
4. Check the SAS cable.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0163
User Response
1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling
the drive.
2. Replace the hard disk drive.
3. Make sure that the disk firmware and RAID controller firmware are at the latest level.
4. Check the SAS cable.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling
the drive.
2. Replace the hard disk drive.
3. Make sure that the disk firmware and RAID controller firmware are at the latest level.
4. Check the SAS cable.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0185
User Response
If the specified sensor is one of the following, ABR Status, Firmware Error or Sys Boot Status: No
action; information only.
Severity
Info
Serviceable
No
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0331
User Response
No action; information only.
Severity
Info
Serviceable
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0331
User Response
No action; information only.
Severity
Info
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Warning - Other
SNMP Trap ID
60
CIM Information
Prefix: PLAT ID: 0399
User Response
No action; information only.
Severity
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0037
User Response
No action; information only.
Severity
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Power
SNMP Trap ID
4
CIM Information
Prefix: PLAT ID: 0087
User Response
No action; information only.
Severity
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0139
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0139
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0139
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0139
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0139
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0139
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0139
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0139
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0139
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0139
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0139
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0139
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0167
User Response
No action; information only.
Severity
Info
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0167
User Response
No action; information only.
Severity
Info
Serviceable
No
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0167
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0167
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0167
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0167
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0167
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0167
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0167
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0167
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0167
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0167
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0167
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0167
User Response
No action; information only.
Severity
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0167
User Response
No action; information only.
Severity
Info
Serviceable
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0167
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0167
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0167
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0167
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0167
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0187
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0225
User Response
1. (Trained technician only) Replace microprocessor n (see Removing a microprocessor and heat
sink and Replacing a microprocessor and heat sink).
2. If the problem persists and there is no other CPU with the same error indication, replace the
system board.
3. (Trained technician only) Replace the system board (see Removing the system board and
Installing the system board). (n = microprocessor number)
Severity
Info
Serviceable
No
Automatically notify support
1. (Trained technician only) Replace microprocessor n (see Removing a microprocessor and heat
sink and Replacing a microprocessor and heat sink).
2. If the problem persists and there is no other CPU with the same error indication, replace the
system board.
3. (Trained technician only) Replace the system board (see Removing the system board and
Installing the system board). (n = microprocessor number)
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0267
User Response
No action; information only. Front Video : PwrPaddle Cable :
CIM Information
Prefix: PLAT ID: 0390
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0390
User Response
No action; information only.
CIM Information
Prefix: PLAT ID: 0390
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0390
User Response
No action; information only.
Severity
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - CPU
SNMP Trap ID
40
CIM Information
Prefix: PLAT ID: 0045
User Response
No action; information only.
Severity
Info
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Predicted Failure
SNMP Trap ID
27
CIM Information
Prefix: PLAT ID: 0169
User Response
No action; information only.
Severity
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Predicted Failure
SNMP Trap ID
27
CIM Information
Prefix: PLAT ID: 0169
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Predicted Failure
SNMP Trap ID
27
CIM Information
Prefix: PLAT ID: 0169
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Predicted Failure
SNMP Trap ID
27
CIM Information
Prefix: PLAT ID: 0169
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Predicted Failure
SNMP Trap ID
27
CIM Information
Prefix: PLAT ID: 0169
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Predicted Failure
SNMP Trap ID
27
CIM Information
Prefix: PLAT ID: 0169
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Predicted Failure
SNMP Trap ID
27
CIM Information
Prefix: PLAT ID: 0169
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Predicted Failure
SNMP Trap ID
27
CIM Information
Prefix: PLAT ID: 0169
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Predicted Failure
SNMP Trap ID
27
CIM Information
Prefix: PLAT ID: 0169
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Predicted Failure
SNMP Trap ID
27
CIM Information
Prefix: PLAT ID: 0169
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Predicted Failure
SNMP Trap ID
27
CIM Information
Prefix: PLAT ID: 0169
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Predicted Failure
SNMP Trap ID
27
CIM Information
Prefix: PLAT ID: 0169
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Predicted Failure
SNMP Trap ID
27
CIM Information
Prefix: PLAT ID: 0169
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Predicted Failure
SNMP Trap ID
27
CIM Information
Prefix: PLAT ID: 0169
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Predicted Failure
SNMP Trap ID
27
CIM Information
Prefix: PLAT ID: 0169
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Predicted Failure
SNMP Trap ID
27
CIM Information
Prefix: PLAT ID: 0169
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0099
User Response
No action; information only.
CIM Information
Prefix: PLAT ID: 0099
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0137
User Response
No action; information only.
Severity
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0137
User Response
No action; information only.
Severity
Info
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0137
User Response
No action; information only.
Severity
Info
Serviceable
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0137
User Response
No action; information only.
Severity
Info
Serviceable
No
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0137
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0137
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0137
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0137
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Memory
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0137
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0137
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0137
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0137
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0137
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0230
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0130
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0130
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0130
User Response
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0130
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0130
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0130
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0130
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0130
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0130
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0130
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0130
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0130
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0130
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0130
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0130
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0130
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0130
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0130
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0130
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0130
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0130
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0130
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0130
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0130
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0130
User Response
No action; information only. One of the DIMMs :
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0233
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - CPU
SNMP Trap ID
40
CIM Information
Prefix: PLAT ID: 0063
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - CPU
SNMP Trap ID
40
CIM Information
Prefix: PLAT ID: 0063
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - CPU
SNMP Trap ID
40
CIM Information
Prefix: PLAT ID: 0063
User Response
No action; information only. One of the CPUs :
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Warning - Memory
SNMP Trap ID
43
CIM Information
Prefix: PLAT ID: 0145
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Warning - Memory
SNMP Trap ID
43
CIM Information
Prefix: PLAT ID: 0145
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Warning - Memory
SNMP Trap ID
43
CIM Information
Prefix: PLAT ID: 0145
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Warning - Memory
SNMP Trap ID
43
CIM Information
Prefix: PLAT ID: 0145
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Warning - Memory
SNMP Trap ID
43
CIM Information
Prefix: PLAT ID: 0145
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Warning - Memory
SNMP Trap ID
43
CIM Information
Prefix: PLAT ID: 0145
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Warning - Memory
SNMP Trap ID
43
CIM Information
Prefix: PLAT ID: 0145
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Warning - Memory
SNMP Trap ID
43
CIM Information
Prefix: PLAT ID: 0145
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Warning - Memory
SNMP Trap ID
43
CIM Information
Prefix: PLAT ID: 0145
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Warning - Memory
SNMP Trap ID
43
CIM Information
Prefix: PLAT ID: 0145
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Warning - Memory
SNMP Trap ID
43
CIM Information
Prefix: PLAT ID: 0145
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Warning - Memory
SNMP Trap ID
43
CIM Information
Prefix: PLAT ID: 0145
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Warning - Memory
SNMP Trap ID
43
CIM Information
Prefix: PLAT ID: 0145
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Warning - Memory
SNMP Trap ID
43
CIM Information
Prefix: PLAT ID: 0145
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Warning - Memory
SNMP Trap ID
43
CIM Information
Prefix: PLAT ID: 0145
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Warning - Memory
SNMP Trap ID
43
CIM Information
Prefix: PLAT ID: 0145
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Warning - Memory
SNMP Trap ID
43
CIM Information
Prefix: PLAT ID: 0145
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Warning - Memory
SNMP Trap ID
43
CIM Information
Prefix: PLAT ID: 0145
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Warning - Memory
SNMP Trap ID
43
CIM Information
Prefix: PLAT ID: 0145
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Warning - Memory
SNMP Trap ID
43
CIM Information
Prefix: PLAT ID: 0145
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Warning - Memory
SNMP Trap ID
43
CIM Information
Prefix: PLAT ID: 0145
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Warning - Memory
SNMP Trap ID
43
CIM Information
Prefix: PLAT ID: 0145
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Warning - Memory
SNMP Trap ID
43
CIM Information
Prefix: PLAT ID: 0145
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Warning - Memory
SNMP Trap ID
43
CIM Information
Prefix: PLAT ID: 0145
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Warning - Memory
SNMP Trap ID
43
CIM Information
Prefix: PLAT ID: 0145
User Response
No action; information only. One of the DIMMs :
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0175
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0175
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0175
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0175
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0175
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0175
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0175
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0175
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0175
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0175
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0175
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0175
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0175
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0175
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0175
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0175
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0175
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0175
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0175
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0175
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0175
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0175
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0175
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0175
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0175
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0175
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0175
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0175
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0175
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0175
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0175
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0175
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - CPU
SNMP Trap ID
40
CIM Information
Prefix: PLAT ID: 0817
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - CPU
SNMP Trap ID
40
CIM Information
Prefix: PLAT ID: 0817
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - CPU
SNMP Trap ID
40
CIM Information
Prefix: PLAT ID: 0817
User Response
No action; information only. One of the CPUs :
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Power
SNMP Trap ID
4
CIM Information
Prefix: PLAT ID: 0105
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0177
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0177
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0177
User Response
No action; information only.
Severity
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0177
User Response
No action; information only.
Severity
Info
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0177
User Response
No action; information only.
Severity
Info
Serviceable
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0177
User Response
No action; information only.
Severity
Info
Serviceable
No
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0177
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0177
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0177
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0177
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0177
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0177
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0177
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0177
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0177
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0177
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0177
User Response
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0177
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0177
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0127
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0127
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0127
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0127
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0127
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0127
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0127
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0127
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0127
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0127
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0127
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0127
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0127
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0127
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0127
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0127
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0127
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0127
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0127
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0127
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0127
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0127
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0127
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0127
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0127
User Response
No action; information only. One of the DIMMs :
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0179
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0179
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0179
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0179
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0179
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0179
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0179
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0179
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0179
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0179
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0179
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0179
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0179
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0179
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0179
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0179
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0179
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0179
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0179
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0179
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0179
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0179
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0179
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0179
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0179
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0179
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0179
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0179
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0179
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0179
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0179
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0179
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0060
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0060
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0060
User Response
No action; information only. One of the CPUs :
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0241
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0241
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0241
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0143
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0143
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0143
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0143
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0143
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0143
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0143
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0143
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0143
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0143
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0143
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0143
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0143
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0143
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0143
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0143
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0143
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0143
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0143
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0143
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0143
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0143
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0143
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0143
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Warning - CPU
SNMP Trap ID
42
CIM Information
Prefix: PLAT ID: 0039
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Warning - CPU
SNMP Trap ID
42
CIM Information
Prefix: PLAT ID: 0039
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0147
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0147
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0147
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0147
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0147
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0147
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0147
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0147
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0147
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0147
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0147
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0147
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0147
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0147
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0147
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0147
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0147
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0147
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0147
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0147
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0147
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0147
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0147
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0147
User Response
No action; information only.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0245
User Response
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0245
User Response
1. (Trained technician only) Replace microprocessor n (see Removing a microprocessor and heat
sink and Replacing a microprocessor and heat sink).
2. If the problem persists and there is no other CPU with the same error indication, replace the
system board.
3. (Trained technician only) Replace the system board (see Removing the system board and
Installing the system board). (n = microprocessor number)
Event identifier
An identifier that uniquely identifies an event.
Event description
The logged message string that appears for an event.
Explanation
Additional information to explain why the event occurred.
Severity
An indication of the level of concern for the condition. The severity is abbreviated in the event log to the
first character. The following severities can be displayed.
User response
The actions that you should take to resolve the event.
Perform the steps in the order shown until the problem is solved. After you perform all of the actions that
are described in this field, if you cannot solve the problem, contact IBM Support.
The following is the list of the UEFI/POST error codes and suggested actions to correct the detected
problems.
• I.11002 [I.11002] A processor mismatch has been detected between one or more processors in
the system.
Explanation: One or More Mismatched Processors Detected
Severity
Error
• I.18005 [I.18005] A discrepancy has been detected in the number of cores reported by one or
more processor packages within the system.
Explanation: Processors have mismatched number of cores
Severity
Error
User Response
Complete the following steps:
1. If this is a newly installed option, ensure that matching Processors are installed in the correct
Processor sockets according to the service information for this product.
2. Check IBM support site for an applicable service bulletin that applies to this Processor error.
3. (Trained Service technician only) Replace Processor. Inspect Processor socket and replace
the system board first if socket is damaged.
• I.18006 [I.18006] A mismatch between the maximum allowed QPI link speed has been detected for
one or more processor packages.
Explanation: Processors have mismatched QPI Speed
Severity
Error
User Response
Complete the following steps:
1. If this is a newly installed option, ensure that matching Processor CPUs are installed in the
correct ProcessorCPU sockets according to the service information for this product
2. Check IBM support site for an applicable retain tipservice bulletin or firmware update that
applies to this Processor error.
3. (Trained Service technician only) Replace Processor. Inspect Processor socket and replace
the system board first if socket is damaged.
• I.18007 [I.18007] A power segment mismatch has been detected for one or more processor
packages.
Severity
Error
User Response
Complete the following steps:
1. Processors installed do not have the same power requirements
2. Ensure that all Processors have matching power requirements (such as 65, 95, or 130 Watts)
3. If power requirements match, check IBM support site for an applicable service bulletin or
firmware update that applies to this Processor error.
4. (Trained Service technician only) Replace Processor. Inspect Processor socket and replace
the system board first if socket is damaged
Severity
Error
User Response
Complete the following steps:
1. Verify that matching DIMMs are installed in the correct population sequence, according to the
service information for this product. {Add link to Memory chart.} Correct any configuration
issues found.
2. (Trained Service technician only) Replace associated Processor. Inspect Processor socket and
replace the system board first if socket is damaged
• I.18009 [I.18009] A core speed mismatch has been detected for one or more processor packages.
Explanation: Processors have mismatched Core Speed
Severity
Error
User Response
Complete the following steps:
1. Verify that matching processors are installed in the correct processor sockets according to the
service information for this product. Correct any mismatch issues found.
2. Check IBM support site for an applicable service bulletin or firmware update that applies to
this Processor error.
3. (Trained Service technician only) Replace Processor. Inspect Processor socket and replace
the system board first if socket is damaged.
• I.1800A [I.1800A] A mismatch has been detected between the speed at which a QPI link has
trained between two or more processor packages.
Explanation: Processors have mismatched Bus Speed
• I.1800B [I.1800B] A cache size mismatch has been detected for one or more processor packages.
Explanation: Processors have one or more cache levels with mismatched size
Severity
Error
User Response
Complete the following steps:
1. Verify that matching processors are installed in the correct processor sockets according to the
service information for this product. Correct any mismatch found.
2. Check IBM support site for an applicable service bulletin or firmware update that applies to
this Processor error.
3. (Trained Service technician only) Replace the system board.
• I.1800C [I.1800C] A cache type mismatch has been detected for one or more processor packages.
Explanation: Processors have one or more cache levels with mismatched type
Severity
Error
User Response
Complete the following steps:
1. Verify that matching Processors are installed in the correct Processor sockets according to the
service information for this product.
2. Check IBM support site for an applicable service bulletin or firmware update that applies to
this Processor error.
3. (Trained Service technician only) Replace the system board.
• I.1800D [I.1800D] A cache associativity mismatch has been detected for one or more processor
packages.
Explanation: Processors have one or more cache levels with mismatched associativity
Severity
• I.1800E [I.1800E] A processor model mismatch has been detected for one or more processor
packages.
Explanation: Processors have mismatched Model Number
Severity
Error
User Response
Complete the following steps:
1. Verify that matching Processors are installed in the correct Processor sockets according to the
service information for this product.
2. Check IBM support site for an applicable service bulletin or firmware update that applies to
this Processor error.
3. (Trained Service technician only) Replace the system board.
• I.1800F [I.1800F] A processor family mismatch has been detected for one or more processor
packages.
Explanation: Processors have mismatched Family
Severity
Error
User Response
Complete the following steps:
1. Verify that matching Processors are installed in the correct Processor sockets according to the
service information for this product
2. Check IBM support site for an applicable service bulletin or firmware update that applies to
this Processor error.
3. (Trained Service technician only) Replace the system board.
• I.18010 [I.18010] A processor stepping mismatch has been detected for one or more processor
packages.
Explanation: Processors of the same model have mismatched Stepping ID
Severity
Error
User Response
• I.2018002 [I.2018002] The device found at Bus % Device % Function % could not be configured
due to resource constraints. The Vendor ID for the device is % and the Device ID is %.
Explanation: OUT_OF_RESOURCES (PCI Option ROM)
Severity
Info
User Response
Complete the following steps:
1. If this PCIe device and/or any attached cables were recently installed, moved, serviced or
upgraded, reseat adapter and any attached cables.
2. Check IBM support site for any applicable service bulletin or UEFI or adapter firmware update
that applies to this error. NOTE: It may be necessary to disable unused option ROMs from UEFI
F1 setup or ASU or using adapter manufacturer utilities so that adapter firmware can be updated.
3. Move card to a different slot. If slot not available or error re-occurs, replace adapter.
4. (Trained Service technician only) If adapter was moved to a different slot and error did not
re-occur, verify that this is not a system limitation and then replace the system board. Also, if
this is not the initial installation and the error persists after adapter replacement, replace system
board.
• I.2018003 [I.2018003] A bad option ROM checksum was detected for the device found at Bus %
Device % Function %. The Vendor ID for the device is % and the Device ID is %.
Explanation: ROM CHECKSUM ERROR
Severity
Error
User Response
Complete the following steps:
1. If this PCIe device and/or any attached cables were recently installed, moved, serviced or
upgraded, reseat adapter and any attached cables.
2. Move adapter to a different system slot, if available.
3. Check IBM support site for any applicable service bulletin or UEFI or adapter firmware update
that applies to this error. NOTE: It may be necessary to configure slot to Gen1 or to use
special utility software so that adapter firmware can be upgraded. Gen1/Gen2 settings can be
configured via F1 Setup -> System Settings -> Devices and I/O Ports -> PCIe Gen1/Gen2/Gen3
Speed Selection, or the ASU Utility.
4. Replace adapter.
Severity
Info
User Response
Complete the following steps:
1. Refer to service information for this product section on UEFI Recovery to return system to
primary bank.
Severity
Info
User Response
Complete the following steps:
1. Use IMM Web Interface to clear event log.
2. If IMM communication is unavailable, use F1 Setup to access System Event Logs Menu and
Choose Clear IMM System Event Log and Restart Server.
• I.3818001 [I.3818001] The firmware image capsule signature for the currently booted flash bank
is invalid.
Explanation: Current Bank CRTM Capsule Update Signature Invalid
Severity
Info
User Response
Complete the following steps:
1. Reboot system. Will come up on backup UEFI image. Reflash the primary UEFI image.
2. If error does not persist no additional recovery action is required.
3. If error persists, or boot is unsuccessful, (Trained service technician only) Replace the system
board.
• I.3818002 [I.3818002] The firmware image capsule signature for the non-booted flash bank is
invalid.
Explanation: Opposite Bank CRTM Capsule Update Signature Invalid
Severity
Info
User Response
Complete the following steps:
1. Reflash backup UEFI image.
2. If error does not persist no additional recovery action is required.
• I.3818003 [I.3818003] The CRTM flash driver could not lock the secure flash region.
Explanation: CRTM Could not lock secure flash region
Severity
Info
User Response
Complete the following steps:
1. If system failed to boot successfully, DC cycle system.
2. If system boots to F1 setup, flash UEFI image and reset bank to primary (if required). If system
boots without error, recovery is complete and no additional action is required.
3. If system fails to boot, or if flash attempt fails, (Trained service technician only) Replace the
system board.
Severity
Info
User Response
Complete the following steps:
1. No user required for this event. This is for informational purposes only.
Severity
Info
User Response
Complete the following steps:
1. Check system event log for uncorrected DIMM failures and replace those DIMMs.
• I.580A5 [I.580A5] Mirror Fail-over complete. DIMM number % has failed over to to the mirrored
copy.
Explanation: DIMM Mirror Fail-over Detected
Severity
Info
User Response
Complete the following steps:
1. Check the system-event log for uncorrected DIMM failures and replace those DIMMs.
Severity
Info
User Response
Complete the following steps:
1. Check system log for related DIMM failures and replace those DIMMs.
Severity
Error
User Response
Complete the following steps:
1. Check IBM support site for an applicable service bulletin or firmware update that applies to
this Processor error.
2. (Trained Service technician only) Replace the Processor.
Severity
Error
User Response
Complete the following steps:
1. Check IBM support site for an applicable service bulletin or firmware update that applies to
this error.
2. Reboot system. If problem persists escalate to the next level of supprt.
• S.2011001 [S.2011001] An Uncorrected PCIe Error has Occurred at Bus % Device % Function %.
The Vendor ID for the device is % and the Device ID is %.
Explanation: PCI SERR Detected
Severity
Error
User Response
Complete the following steps:
1. If this node and/or any attached cables were recently installed, moved, serviced or upgraded, a.
Reseat Adapter and any attached cables. b. Reload Device Driver c. If device is not recognized,
reconfiguring slot to Gen1 or Gen2 may be required. Gen1/Gen2 settings can be configured
• S.2018001 [S.2018001] An Uncorrected PCIe Error has Occurred at Bus % Device % Function %.
The Vendor ID for the device is % and the Device ID is %.
Explanation: PCIe Uncorrected Error Detected
Severity
Error
User Response
Complete the following steps:
1. If this node and/or any attached cables were recently installed, moved, serviced or upgraded, a.
Reseat Adapter and any attached cables. b. Reload Device Driver c. If device is not recognized,
reconfiguring slot to Gen1 or Gen2 may be required. Gen1/Gen2 settings can be configured
via F1 Setup -> System Settings -> Devices and I/O Ports -> PCIe Gen1/Gen2/Gen3 Speed
Selection, or the ASU Utility.
2. Check IBM support site for an applicable device driver, firmware update, version of service
information for this product or other information that applies to this error. Load new device driver
and any required firmware updates.
3. If problem persists, then remove Adapter Card. If system reboots successfully without the
adapter, replace that card.
4. Trained Service technician only) Replace the processor.
• S.3020007 [S.3020007] A firmware fault has been detected in the UEFI image.
Explanation: Internal UEFI Firmware Fault Detected, System halted
Severity
Error
User Response
Complete the following steps:
1. Check IBM support site for an applicable service bulletin or firmware update that applies to
this error.
2. Reflash UEFI image.
3. (Trained service technician only) Replace the system board.
• S.3030007 [S.3030007] A firmware fault has been detected in the UEFI image.
Explanation: Internal UEFI Firmware Fault Detected, System halted
Severity
Error
User Response
Complete the following steps:
1. Check IBM support site for an applicable service bulletin or firmware update that applies to
this error.
2. Reflash UEFI image.
3. (Trained service technician only) Replace the system board.
• S.3040007 [S.3040007] A firmware fault has been detected in the UEFI image.
Explanation: Internal UEFI Firmware Fault Detected, System halted
Severity
Error
User Response
Complete the following steps:
1. Check IBM support site for an applicable service bulletin or firmware update that applies to
this error.
2. Reflash UEFI image.
3. (Trained service technician only) Replace the system board.
• S.3050007 [S.3050007] A firmware fault has been detected in the UEFI image.
Explanation: Internal UEFI Firmware Fault Detected, System halted
Severity
Error
User Response
Complete the following steps:
1. Check IBM support site for an applicable service bulletin or firmware update that applies to
this error.
2. Reflash UEFI image.
3. (Trained service technician only) Replace the system board.
Severity
Error
User Response
Complete the following steps:
1. This event resets UEFI to the default settings for the next boot. If successful, user is forced into
F1 setup. Original UEFI settings are still present.
2. If User did not intentionally trigger the reboots, check logs for probable cause.
3. Undo recent system changes (settings or devices added). If not recent system changes, remove
all options then remove CMOS battery for 30 seconds to clear CMOS contents. Verify that the
system boots. Then, re-install options one at a time to locate the problem.
4. Check IBM support site for an applicable service bulletin or firmware update that applies to
this error.
5. Reflash UEFI firmware.
6. Remove and re-install CMOS battery for 30 seconds to clear CMOS contents
7. (Trained service technician only) Replace the system board.
• S.3060007 [S.3060007] A firmware fault has been detected in the UEFI image.
Explanation: Internal UEFI Firmware Fault Detected, System halted
Severity
Error
User Response
Complete the following steps:
1. Check IBM support site for an applicable service bulletin or firmware update that applies to
this error.
2. Reflash UEFI image.
3. (Trained service technician only) Replace the system board.
• S.3070007 [S.3070007] A firmware fault has been detected in the UEFI image.
Explanation: Internal UEFI Firmware Fault Detected, System halted
Severity
Error
User Response
Complete the following steps:
1. Check IBM support site for an applicable service bulletin or firmware update that applies to
this error.
2. Reflash UEFI image.
3. (Trained service technician only) Replace the system board.
Severity
Error
User Response
Complete the following steps:
1. Check IBM support site for an applicable service bulletin or firmware update that applies to
this error.
• S.3818004 [S.3818004] The CRTM flash driver could not successfully flash the staging area. A
failure occurred.
Explanation: CRTM Update Failed
Severity
Error
User Response
Complete the following steps:
1. Continue booting sytem. If system does not reset, manually reset the system.
2. If the error is not reported on the subsequent boot, no additional recovery action is required.
3. If the error persists, continue booting system and reflash UEFI image.
4. (Trained service technician only) Replace the system board.
• S.3818007 [S.3818007] The firmware image capsules for both flash banks could not be verified.
Explanation: CRTM image capsule could not be verified
Severity
Error
User Response
Complete the following steps:
1. If system failed to boot successfully, DC cycle system.
2. If system boots to F1 steup, flash UEFI image and reset bank to primary (if required). If system
boots without error, recovery is complete and no additional action is required.
3. If system fails to boot, or if flash attempt fails, (Trained service technician only) Replace the
system board.
• S.51003 [S.51003] An uncorrectable memory error was detected in DIMM slot % on rank %.
Explanation: [S.51003] An uncorrectable memory error was detected on processor % channel %. The
failing DIMM within the channel could not be determined.[S.51003] An uncorrectable memory error has
been detected during POST. Fatal Memory Error Occurred
Severity
Error
• S.51006 [S.51006] A memory mismatch has been detected. Please verify that the memory
configuration is valid.
Explanation: One or More Mismatched DIMMs Detected
Severity
Error
User Response
Complete the following steps:
1. Could follow an uncorrectable memory error or failed memory test. Check log and service that
event first. DIMMs disabled by other errors or actions could cause this event.
2. Verify that the DIMMs are installed in the correct population sequence, according to the service
information for this product.
3. Disable memory mirroring and sparing. If this action eliminates the mismatch, check IBM
Support site for information related to this problem.
4. Reflash UEFI firmware.
5. Replace DIMM
6. (Trained Service technician only) Replace Processor.
Severity
Error
User Response
Complete the following steps:
1. Make sure that one or more DIMMs are installed in the server.
Severity
Error
User Response
Complete the following steps:
1. You must AC-cycle the system to re-enable affected DIMM connector or re-enable manually
using F1 setup
2. If the node has been recently installed, serviced, moved, or upgraded, check to ensure that
DIMMs are firmly seated and that no foreign material can be seen in the DIMM connector. If
either condition is observed, correct and retry with the same DIMM. (Note: Event Log may
contain a recent 00580A4 event denoting detected change in DIMM population that could
be related to this problem.)
3. If problem persists, replace the DIMM identified by LightPath and/or event log entry.
4. If problem re-occurs on the same DIMM connector, swap the other DIMMs on the same memory
channel across channels one at a time to a different memory channel or Processor. (check
service information for this product/Install guide for population requirements for sparing/paring
modes). If problem follows a moved DIMM to a different memory channel, replace that DIMM.
5. Check IBM support site for an applicable service bulletin or firmware update that applies to this
memory error.
6. (Trained service technician only) If problem stays with the original DIMM connector, re-inspect
DIMM connector for foreign material and remove, if found. If connector is damaged, replace
system board.
7. (Trained service technician only) Remove affected Processor and inspect Processor socket pins
for damaged or mis-aligned pins. If damage is found, or this is an upgrade Processor, replace
system board. If there are multiple Processor’s, swap Processor’s to move affected Procesor to
another Processor socket and retry. If problem follows the affected Processor (or there is only
one Processor), replace the affected Processor.
8. (Trained Service technician only) Replace the system board.
• S.68005 [S.68005] An error has been detected by the the IIO core logic on Bus %. The Global Fatal
Error Status register contains %. The Global Non-Fatal Error Status register contains %. Please
check error logs for the presence of additional downstream device error data.
Explanation: Critical IOH-PCI Error
Severity
Error
User Response
Severity
Error
User Response
Complete the following steps:
1. Check IBM support site for an applicable service bulletin or firmware update that applies to
this error.
2. Inspect processor socket for foreign debris or damage. If debris is found remove debris.
3. If error recurs, or socket damage is found, replace the system board (Trained Service technician
only) .
4. (Trained Service Technician Only) Replace the processor.
Severity
Error
User Response
Complete the following steps:
1. Check IBM support site for an applicable service bulletin or firmware update that applies to
this error.
2. Inspect processor socket for foreign debris or damage. If debris is found remove debris.
3. If error recurs, or socket damage is found, replace the system board (Trained Service technician
only) .
• W.11004 [W.11004] A processor within the system has failed the BIST.
Explanation: Processor Self Test Failure Detected
Severity
Error
User Response
Complete the following steps:
1. If the Processor or firmware was just updated, check IBM support site for an applicable service
bulletin or firmware update that applies to this Processor error.
• W.3048006 [W.3048006] UEFI has booted from the backup flash bank due to an Automatic Boot
Recovery (ABR) event.
Explanation: Automated Boot Recovery, Booting Backup UEFI Image
Severity
Warning
User Response
Complete the following steps:
1. Check IBM support site for an applicable service bulletin or firmware update that applies to
this error.
2. Reflash Primary UEFI image. Refer to UEFI Recovery section of service information for this
product.
3. (Trained service technician only) Replace the system board.
Severity
Warning
User Response
Complete the following steps:
1. Check IMM/chassis event log. This event should immediately precede 0068002 error. Service
that event or any other battery related errors.
2. Use F1 Setup to reset date and time. If problem returns after a system reset, replace CMOS
battery.
3. If problem persists then check IBM support site for an applicable service bulletin or firmware
update that applies to this error.
4. Trained Service technician only) Replace the system board.
Severity
Warning
User Response
Complete the following steps:
Severity
Warning
User Response
Complete the following steps:
1. Reboot the system.
2. If problem persists, switch to backup UEFI or reflash current UEFI image.
3. (Trained Service Technician Only) Replace system board.
Severity
Warning
User Response
Complete the following steps:
1. No action required – system will reboot at the end of POST.
2. If problem persists, switch to backup UEFI or reflash current UEFI image.
3. (Trained Service Technician Only) Replace system board.
Severity
Warning
User Response
Complete the following steps:
1. Reboot the system.
2. If problem persists, switch to backup UEFI or reflash current UEFI image.
3. (Trained Service Technician Only) Replace system board.
Severity
Warning
User Response
Complete the following steps:
1. Reboot the system to reconnect the controller.
2. If problem persists, switch to backup UEFI or reflash current UEFI image.
3. (Trained Service Technician Only) Replace system board.
• W.305800E [W.305800E] DRIVER HEALTH PROTOCOL: Reports Invalid Health Status Driver.
Explanation: DRIVER HEALTH PROTOCOL: Reports Invalid Health Status Driver
Severity
Warning
User Response
Complete the following steps:
1. Reboot the system.
2. If problem persists, switch to backup UEFI or reflash current UEFI image.
3. (Trained Service Technician Only) Replace system board.
Severity
Warning
User Response
Complete the following steps:
1. Remove AUX power from the node. This will reboot the entire node.
2. Check IBM support site for an applicable service bulletin or firmware update that applies to
this error.
3. Reflash UEFI Firmware.
4. (Trained service technician only) Replace the system board.
• W.3808002 [W.3808002] An error occurred while saving UEFI settings to the IMM.
Explanation: Error Updating System Configuration to IMM
Severity
Warning
User Response
Complete the following steps:
1. Use F1 Setup, Verify Settings and Save Settings to recover settings.
2. Remove AUX power from the node. This will reboot the entire node.
• W.3808003 .[W.3808003] Unable to retrieve the system configuration from the IMM.
Explanation: Error Retrieving System Configuration from IMM
Severity
Warning
User Response
Complete the following steps:
1. Use F1 Setup, Verify Settings and Save Settings to recover settings.
2. Remove AUX power from the node. This will reboot the entire node.
3. Check IBM support site for an applicable service bulletin or firmware update that applies to
this error.
4. Reflash IMM Firmware.
5. Remove and re-install CMOS battery for 30 seconds to clear CMOS contents.
6. Trained Service technician only) Replace the system board.
• W.3818005 [W.3818005] The CRTM flash driver could not successfully flash the staging area. The
update was aborted
Explanation: CRTM Update Aborted
Severity
Warning
User Response
Complete the following steps:
1. Continue booting system. If system does not reset, manually reset the system.
2. If the error is not reported on the subsequent boot, no additional recovery action is required.
3. If the event persists, continue booting system and reflash UEFI image.
4. (Trained service technician only) Replace the system board.
Severity
Warning
User Response
Complete the following steps:
1. F1 Setup -> Save Settings
• W.50001 [W.50001] A DIMM has been disabled due to an error detected during POST.
Explanation: DIMM Disabled
Severity
Info
User Response
Complete the following steps:
1. If the DIMM was disabled because of a memory fault, follow the procedure for that event.
2. If no memory fault is recorded in the logs and no DIMM connector error LEDs are lit, re-enable
the DIMM through the Setup utility or the Advanced Settings Utility (ASU).
3. If problem persists, Power cycle the node from management console.
4. Reset IMM to default settings.
5. Reset UEFI to default settings.
6. Reflash IMM and UEFI firmware.
7. (Trained Service technician only) Replace system board.
• W.58001 [W.58001] The PFA Threshold limit (correctable error logging limit) has been exceeded on
DIMM number % at address %. MC5 Status contains % and MC5 Misc contains %.
Explanation: DIMM PFA Threshold Exceeded
Severity
Error
User Response
Complete the following steps:
1. If the node has recently been installed, moved, serviced, or upgraded, verify that the DIMM
is properly seated and visually verify that there is no foreign material in any DIMM connector
on that memory channel. If either of these conditions is found, correct and retry with the same
DIMM. (Note: Event Log may contain a recent 00580A4 event denoting detected change in
DIMM population that could be related to this problem.)
2. Check IBM support site for an applicable firmware update that applies to this memory error. The
release notes will list the known problems the update addresses.
3. If the previous steps do not resolve the problem, at the next maintenance opportunity, replace
the affected DIMM (as indicated by LightPath and/or failure log entry).
4. If PFA re-occurs on the same DIMM connector, swap the other DIMMs on the same memory
channel one at a time to a different memory channel or Processor. (check service information for
this product/Install guide for population requirements for sparing/paring modes). If PFA follows a
moved DIMM to any DIMM connector on the different memory channel, replace the moved DIMM.
5. Check IBM support site for an applicable Service Bulletins (Service bulletins) that applies to this
memory error. (Link to IBM support service bulletins)
6. (Trained service technician only) If problem continues to re-occur on the same DIMM connector,
inspect DIMM connector for foreign material and remove, if found. If connector is damaged,
replace system board.
• W.58007 [W.58007] Invalid memory configuration (Unsupported DIMM Population) detected. Please
verify memory configuration is valid.
Explanation: Unsupported DIMM Population
Severity
Error
User Response
Complete the following steps:
1. Could follow an uncorrectable memory error or failed memory test. Check log and service that
event first. DIMMs disabled by other errors or actions could cause this event.
2. Ensure that the DIMM connectors are populated according to the guidelines in the service
information for this product.
• W.580A1 [W.580A1] Invalid memory configuration for Mirror Mode. Please correct memory
configuration.
Explanation: Unsupported DIMM Population for Mirror Mode
Severity
Error
User Response
Complete the following steps:
1. If a DIMM connector error LED is lit, resolve the failure.
2. Make sure that the DIMM connectors are correctly populated for mirroring mode, according to
the service information for this product.
• W.580A2 [W.580A2] Invalid memory configuration for Sparing Mode. Please correct memory
configuration.
Explanation: Unsupported DIMM Population for Spare Mode
Severity
Error
User Response
Complete the following steps:
1. Make sure that the DIMM connectors are correctly populated for sparing mode, according to
the service information for this product.
Severity
Error
User Response
Complete the following steps:
1. If the system was recently Installed, Moved, or Serviced, makesure the batter is properly seated.
2. Check IBM support site for an applicable service bulletin or firmware update that applies to
this error.
3. Replace CMOS Battery
4. (Trained Service technician only) Replace the system board.
Recoverable
No
Severity
Event
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Event
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Event
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Event
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Event
Serviceable
No
Automatically notify support
No
Recoverable
No
Severity
Event
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Event
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Check component firmware level and upgrade if necessary. The installed firmware level can be
found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component.
2. Rerun the test.
3. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related links
Recoverable
No
Severity
Error
Serviceable
Yes
Related links
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Check component firmware level and upgrade if necessary. The installed firmware level can be
found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component.
2. Rerun the test.
3. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related links
Recoverable
No
Severity
Related links
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Check component firmware level and upgrade if necessary. The installed firmware level can be
found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component.
2. Rerun the test.
3. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related links
Related links
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Check component firmware level and upgrade if necessary. The installed firmware level can be
found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component.
2. Rerun the test.
3. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related links
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Check component firmware level and upgrade if necessary. The installed firmware level can be
found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component.
2. Rerun the test.
3. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related links
Recoverable
No
Severity
Event
Serviceable
No
Automatically notify support
No
Recoverable
No
Severity
Event
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Event
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Recoverable
No
Severity
Event
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Event
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Event
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Rerun the test.
2. Verify whether the firmware is at proper level.
3. Rerun the test.
4. If the problem remains, contact your IBM technical-support representative.
Related links
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Check cable connections.
2. Rerun the test.
3. Verify whether the firmware is at proper level.
4. Rerun the test.
5. If the problem remains, contact your IBM technical-support representative.
Related links
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Rerun the test.
2. Verify whether the firmware is at proper level.
3. Rerun the test.
4. If the problem remains, contact your IBM technical-support representative.
Related links
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Rerun the test.
2. Verify whether the firmware is at proper level.
3. Rerun the test.
4. If the problem remains, contact your IBM technical-support representative.
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Check or replace SFP/cable.
2. Rerun the test.
3. Verify whether the firmware is at proper level.
4. Rerun the test.
5. If the problem remains, contact your IBM technical-support representative.
Related links
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Rerun the test.
Related links
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Rerun the test.
2. Verify whether the firmware is at proper level.
3. Rerun the test.
4. If the problem remains, contact your IBM technical-support representative.
Related links
Recoverable
No
Severity
Warning
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Inspect and reseat operator information panel cable at both ends.
2. Verify that the Baseboard Management Controller (BMC) is working.
3. Run the test again.
4. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related links
Recoverable
No
Severity
Related links
Recoverable
No
Severity
Event
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Warning
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Turn off and restart the system.
2. Make sure that the DSA Diagnostic code is at the latest level.
3. Run the test again.
4. Check system firmware level and upgrade if necessary. The installed firmware level can be
found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component.
The latest level firmware for this component can be found in reference to this system type at
the IBM Support website.
5. Run the test again.
6. If the system has stopped responding, turn off and restart the system and then run the test again.
7. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related links
Recoverable
No
Severity
Warning
Serviceable
Yes
Automatically notify support
No
User Response
Related links
Recoverable
No
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Related links
Recoverable
No
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. If the system has stopped responding, turn off and restart the system and then run the test again.
2. Make sure that the DSA Diagnostic code is at the latest level.
3. Run the test again.
4. Check system firmware level and upgrade if necessary. The installed firmware level can be found
in the DSA Diagnostic Event Log within the Firmware/VPD section for this component.
5. Run the test again.
6. If the system has stopped responding, turn off and restart the system and then run the test again.
7. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related links
Recoverable
No
Severity
Event
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Event
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Event
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Warning
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Check component firmware level and upgrade if necessary. The installed firmware level can be
found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component.
2. Rerun the test.
3. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related links
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
Related links
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Check component firmware level and upgrade if necessary. The installed firmware level can be
found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component.
2. Rerun the test.
3. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related links
Recoverable
No
Severity
Event
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Warning
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Remove power cables, wait for 45 seconds, reconnect and rerun the test.
2. Make sure that the scalability cable connections are as per specification.
3. Make sure that DSA and BIOS/uEFI are at the latest level.
4. If the problem remains, contact your technical-service representative.
Related links
Recoverable
Related links
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Remove power cables, wait for 45 seconds, reconnect and rerun the test.
2. Make sure that the scalability cable connections are as per specification.
3. Check scalability cables for loose connections.
4. Replace the scalability cable(s) for specified port(s).
5. If the problem remains, contact your technical-service representative.
Related links
Recoverable
No
Severity
Event
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Warning
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Check cable connections.
2. Rerun the test.
3. Verify that Hard drive supports self test and self test logging.
4. If the problem remains, contact your technical-support representative.
Related links
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Check cable connections.
2. Rerun the test.
3. Verify the firmware is at the latest level.
4. Rerun the test.
5. If the problem remains, contact your technical-support representative.
Related links
Recoverable
No
Severity
Event
Recoverable
No
Severity
Event
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Event
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Event
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Event
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Warning
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Check component firmware level and upgrade if necessary. The installed firmware level can be
found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component.
2. Rerun the test.
3. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service
Guide" for the next corrective action.
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Check component firmware level and upgrade if necessary. The installed firmware level can be
found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component.
2. Rerun the test.
3. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related links
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Check component firmware level and upgrade if necessary. The installed firmware level can be
found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component.
Related links
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Check component firmware level and upgrade if necessary. The installed firmware level can be
found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component.
2. Rerun the test.
3. Check interrupt assignments in the PCI Hardware section of the DSA Diagnostic Log. If the
ethernet device is sharing interrupts, if possible modify the interrupt assignments using F1
Setup to assign a unique interrupt to the device.
4. Rerun the test.
5. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related links
Recoverable
No
Severity
Error
Serviceable
Related links
Recoverable
No
Severity
Event
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Check cable connections.
2. Rerun the test.
3. Verify whether the firmware is at the latest level.
4. Rerun the test.
5. If the problem remains, contact your IBM technical-support representative.
Related links
Recoverable
No
Severity
Event
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Event
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Warning
Serviceable
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Make sure that the physical link of the port under test in the active state.
2. If these condition was met but the test keeps failing the port's adapter might be faulty.
3. Try replacing the adapter and repeating the test.
Related links
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Make sure that the physical link of the port under test in the active state and a subnet manager
running on the fabric to which the port is attached.
2. If these condition was met but the test keeps failing the port's adapter might be faulty.
3. Try replacing the adapter and repeating the test.
Related links
Recoverable
No
Severity
Event
Serviceable
No
Recoverable
No
Severity
Event
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Event
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Event
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
5. Replace any DIMMS(s) mentioned in error, one by one.
6. Make sure that all DIMMs are enabled in the Configuration/Setup Utility program.
7. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related links
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
Related links
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
5. Replace any DIMMS(s) mentioned in error, one by one.
6. Make sure that all DIMMs are enabled in the Configuration/Setup Utility program.
7. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related links
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
5. Replace any DIMMS(s) mentioned in error, one by one.
6. Make sure that all DIMMs are enabled in the Configuration/Setup Utility program.
7. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related links
Recoverable
No
Severity
Event
Recoverable
No
Severity
Warning
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Turn off and restart the system.
2. Make sure that the DSA Diagnostic code is at the latest level.
3. Run the test again.
4. If the system has stopped responding, turn off and restart the system.
5. Check the system firmware level and upgrade if necessary.
6. Run the memory diagnostic to identify the specific failing DIMM.
7. If the failure remains, refer to "Troubleshooting by symptom" in the system "Installation and
Service Guide" for the next corrective action.
Related links
Recoverable
No
Severity
Warning
Recoverable
No
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Related links
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Execute the standard DSA memory diagnostics to validate all memory.
2. Make sure that the DSA Diagnostic code is at the latest level.
3. Turn off the system and disconnect it from power.
4. Reseat the memory cards and DIMMs.
5. Reconnect the system to power and turn the system on.
Related links
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Ensure that all memory is enabled by checking the "Available System Memory" in the "Resource
Utilization" section of the DSA Diagnostic Event log.
2. If necessary, access the Configuration/Setup Utility program by pressing F1 during system
boot and enable all memory.
3. Make sure that the DSA Diagnostic code is at the latest level.
4. Run the test again.
5. Execute the standard DSA memory diagnostics to validate all memory.
6. If the failure remains, refer to "Troubleshooting by symptom" in the system "Installation and
Service Guide" for the next corrective action.
Related links
Recoverable
No
Severity
Event
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Event
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Event
Serviceable
Recoverable
No
Severity
Event
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Event
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Event
Serviceable
Yes
Related links
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Verify that the GPU is seated in the PCIe slot correctly by reseating the GPU. Then power cycle
the system.
2. Verify that the power connectors to the GPU are connected firmly. Then power cycle the system.
3. Run nvidia-smi -q In some cases this will report a poorly connected power cable.
4. Rerun the diagnostics, using the same GPU, on system that is known to be working. A variety of
system issues can cause diagnostic failure.
5. If the problem remains, contact your IBM technical-support representative.
Related links
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Verify that the GPU is seated in the PCIe slot correctly by reseating the GPU. Then power cycle
the system.
2. Verify that the power connectors to the GPU are connected firmly. Then power cycle the system.
3. Run nvidia-smi -q In some cases this will report a poorly connected power cable.
4. Rerun the diagnostics, using the same GPU, on system that is known to be working. A variety of
system issues can cause diagnostic failure.
5. If the problem remains, contact your IBM technical-support representative.
Related links
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Verify that the GPU is seated in the PCIe slot correctly by reseating the GPU. Then power cycle
the system.
2. Verify that the power connectors to the GPU are connected firmly. Then power cycle the system.
3. Run nvidia-smi -q In some cases this will report a poorly connected power cable.
4. Rerun the diagnostics, using the same GPU, on system that is known to be working. A variety of
system issues can cause diagnostic failure.
5. If the problem remains, contact your IBM technical-support representative.
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Verify that the GPU is seated in the PCIe slot correctly by reseating the GPU. Then power cycle
the system.
2. Verify that the power connectors to the GPU are connected firmly. Then power cycle the system.
3. Run nvidia-smi -q In some cases this will report a poorly connected power cable.
4. Rerun the diagnostics, using the same GPU, on system that is known to be working. A variety of
system issues can cause diagnostic failure.
5. If the problem remains, contact your IBM technical-support representative.
Related links
Recoverable
Recoverable
No
Severity
Warning
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Make sure that the DSA Diagnostic code is at the latest level.
2. Run the test again.
3. Check the drive cabling for loose or broken connections at both ends or damage to the cable.
Replace the cable if damage is present.
4. Run the test again.
5. Check system firmware level and upgrade if necessary.The installed firmware level can be found
in the DSA Diagnostic Event Log within the Firmware/VPD section for this component.
6. Run the test again.
Related links
Recoverable
No
Related links
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Wait for the system activity to cease
2. Run the test again
3. Turn off and restart the system.
4. Run the test again.
Related links
Recoverable
No
Severity
Warning
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Close the media tray and wait for 15 seconds for the media to be recognized. Run the test again.
2. Insert a new CD or DVD into the drive and wait for 15 seconds for the media to be recognized.
Rerun the test.
3. Check the drive cabling for loose or broken connections at both ends or damage to the cable.
Replace the cable if damage is present.
4. Run the test again.
5. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related links
Recoverable
No
Severity
Warning
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Insert a new CD or DVD into the drive and wait for 15 seconds for the media to be recognized.
Rerun the test.
2. Check the drive cabling for loose or broken connections at both ends or damage to the cable.
Replace the cable if damage is present.
3. Run the test again.
Related links
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Insert a new CD or DVD into the drive and wait for 15 seconds for the media to be recognized.
Rerun the test.
2. Check the drive cabling for loose or broken connections at both ends or damage to the cable.
Replace the cable if damage is present.
3. Run the test again.
4. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related links
Recoverable
No
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Related links
Recoverable
No
Severity
Event
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Warning
Serviceable
Yes
Automatically notify support
No
User Response
Perform the actions mentioned one at a time and try the test after each action:
1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
Yes
Automatically notify support
No
User Response
Perform the actions mentioned one at a time and try the test after each action:
1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the latest level.
Related links
Related links
Recoverable
No
Severity
Warning
Serviceable
Yes
Automatically notify support
No
User Response
Perform the actions mentioned one at a time and try the test after each action:
1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the latest level.
Related links
Recoverable
No
Related links
Recoverable
No
Severity
Warning
Serviceable
Yes
Automatically notify support
No
User Response
Perform the actions mentioned one at a time and try the test after each action:
1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the latest level.
Related links
Recoverable
No
Severity
Warning
Related links
Recoverable
No
Severity
Warning
Serviceable
Yes
Automatically notify support
No
User Response
Perform the actions mentioned one at a time and try the test after each action:
1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
Yes
Related links
Recoverable
No
Severity
Warning
Serviceable
Yes
Automatically notify support
No
User Response
Perform the actions mentioned one at a time and try the test after each action:
1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Related links
Recoverable
No
Severity
Warning
Serviceable
Yes
Automatically notify support
No
User Response
Perform the actions mentioned one at a time and try the test after each action:
1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
Yes
Automatically notify support
No
User Response
Perform the actions mentioned one at a time and try the test after each action:
Related links
Recoverable
No
Severity
Warning
Serviceable
Yes
Automatically notify support
No
User Response
Perform the actions mentioned one at a time and try the test after each action:
1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
Yes
Automatically notify support
No
User Response
Perform the actions mentioned one at a time and try the test after each action:
1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the latest level.
Recoverable
No
Severity
Warning
Serviceable
Yes
Automatically notify support
No
User Response
Perform the actions mentioned one at a time and try the test after each action:
1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
Yes
Automatically notify support
No
User Response
Perform the actions mentioned one at a time and try the test after each action:
1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
Yes
Automatically notify support
No
User Response
Perform the actions mentioned one at a time and try the test after each action:
1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
Yes
Automatically notify support
No
User Response
Perform the actions mentioned one at a time and try the test after each action:
1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
Yes
Automatically notify support
No
User Response
Perform the actions mentioned one at a time and try the test after each action:
1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
Yes
Automatically notify support
No
User Response
Perform the actions mentioned one at a time and try the test after each action:
1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
Yes
Automatically notify support
No
User Response
Perform the actions mentioned one at a time and try the test after each action:
1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
Yes
Automatically notify support
No
User Response
Perform the actions mentioned one at a time and try the test after each action:
1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the latest level.
Related links
Recoverable
No
Severity
Warning
Serviceable
Yes
Automatically notify support
No
User Response
Perform the actions mentioned one at a time and try the test after each action:
1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the latest level.
Related links
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Perform the actions mentioned one at a time and try the test after each action:
1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the latest level.
3. Run the test again.
4. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related links
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Perform the actions mentioned one at a time and try the test after each action:
1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the latest level.
3. Run the test again.
4. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related links
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Perform the actions mentioned one at a time and try the test after each action:
1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the latest level.
3. Run the test again.
4. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related links
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Perform the actions mentioned one at a time and try the test after each action:
1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the latest level.
3. Run the test again.
4. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related links
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Perform the actions mentioned one at a time and try the test after each action:
1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the latest level.
3. Run the test again.
Related links
Recoverable
No
Severity
Event
Serviceable
No
Automatically notify support
No
Related links
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
Related links
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Clean the tape drive using the appropriate cleaning media and install new media.
2. Run the test again.
3. Make sure that the drive firmware is at the latest level.
4. Rerun the test after upgrading to the latest firmware level.
5. If the failure remains, refer to "Troubleshooting by symptom" in the system "Installation and
Service Guide" for the next corrective action.
Related links
Related links
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Check the tape drive cabling for loose or broken connections or damage to the cable. Replace
the cable if damage is present.
2. Clean the tape drive using the appropriate cleaning media and install new media.
3. Run the test again.
4. Make sure that the drive firmware is at the latest level.
5. Rerun the test after upgrading to the latest firmware level.
6. If the failure remains, refer to "Troubleshooting by symptom" in the system "Installation and
Service Guide" for the next corrective action.
Related links
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. If the system has stopped responding, turn off and restart the system.
2. Check the system firmware level and upgrade if necessary. The installed firmware level can be
found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component.
3. Run the test again.
4. If the system has stopped responding, turn off and restart the system.
5. Make sure that the drive firmware is at the latest level.
6. Run the test again.
7. If the failure remains, refer to "Troubleshooting by symptom" in the system "Installation and
Service Guide" for the next corrective action.
Related links
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
Related links
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Clean the tape drive using the appropriate cleaning media and install new media.
Related links
Recoverable
No
Severity
Related links
– Support website
– Latest level of DSA
– Latest level of BMC/IMM
Use this information to obtain additional information about Lenovo and Lenovo products, and determine
what to do if you experience a problem with your Lenovo system or optional device.
Note: This section includes references to IBM web sites and information about obtaining service. IBM is
Lenovo's preferred service provider for the System x, Flex System, and NeXtScale System products.
If you believe that you require warranty service for your Lenovo product, the service technicians will be able
to assist you more efficiently if you prepare before you call.
• Check all cables to make sure that they are connected.
• Check the power switches to make sure that the system and any optional devices are turned on.
• Check for updated software, firmware, and operating-system device drivers for your Lenovo product. The
Lenovo Warranty terms and conditions state that you, the owner of the Lenovo product, are responsible
for maintaining and updating all software and firmware for the product (unless it is covered by an
additional maintenance contract). Your service technician will request that you upgrade your software and
firmware if the problem has a documented solution within a software upgrade.
• If you have installed new hardware or software in your environment, check http://www.lenovo.com/
serverproven/ to make sure that the hardware and software is supported by your product.
• Go to http://www.lenovo.com/support to check for information to help you solve the problem.
• Gather the following information to provide to the service technician. This data will help the service
technician quickly provide a solution to your problem and ensure that you receive the level of service
for which you might have contracted.
– Hardware and Software Maintenance agreement contract numbers, if applicable
– Machine type number (Lenovo 4-digit machine identifier)
– Model number
– Serial number
– Current system UEFI and firmware levels
– Other pertinent information such as error messages and logs
• Go to http://www.ibm.com/support/ entry/portal/Open_service_request to submit an Electronic Service
Request. Submitting an Electronic Service Request will start the process of determining a solution to
your problem by making the pertinent information available to the service technicians. The IBM service
technicians can start working on your solution as soon as you have completed and submitted an
Electronic Service Request.
You can solve many problems without outside assistance by following the troubleshooting procedures
that Lenovo provides in the online help or in the Lenovo product documentation. The Lenovo product
documentation also describes the diagnostic tests that you can perform. The documentation for most
systems, operating systems, and programs contains troubleshooting procedures and explanations of error
messages and error codes. If you suspect a software problem, see the documentation for the operating
system or program.
See the troubleshooting information in your system documentation for instructions for using the diagnostic
programs. The troubleshooting information or the diagnostic programs might tell you that you need
additional or updated device drivers or other software. Lenovo maintains pages on the World Wide Web
where you can get the latest technical information and download device drivers and updates. To access
these pages, go to http://www.lenovo.com/support.
On the World Wide Web, up-to-date information about Lenovo systems, optional devices, services,
and support is available at http://www.lenovo.com/support. The most current version of the product
documentation is available in the following product-specific Information Centers:
• Flex System products:
http://pic.dhe.ibm.com/infocenter/ flexsys/information/index.jsp
• System x products:
http://shop.lenovo.com/us/ en/systems/
• NeXtScale System products:
http://pic.dhe.ibm.com/infocenter/ nxtscale/documentation/index.jsp
Before you send diagnostic data to IBM, read the terms of use at http://www.ibm.com/de/support/
ecurep/terms.html.
You can use any of the following methods to send diagnostic data:
• Standard upload:
http://www.ibm.com/de/support/ ecurep/send_http.html
• Standard upload with the system serial number:
http://www.ecurep.ibm.com/app/ upload_hw
• Secure upload:
http://www.ibm.com/de/support/ ecurep/send_http.html#secure
• Secure upload with the system serial number:
https://www.ecurep.ibm.com/ app/upload_hw
For more information about Support Line and other IBM services, see http://www.ibm.com/services
or see http://www.ibm.com/planetwide for support telephone numbers. In the U.S. and Canada, call
1-800-IBM-SERV (1-800-426-7378).
You can receive hardware service through your Lenovo reseller or from IBM. To locate a reseller authorized
by Lenovo to provide warranty service, go to http://www.ibm.com/partnerworld and click Business Partner
Locator. For IBM support telephone numbers, see http://www.ibm.com/planetwide. In the U.S. and
Canada, call 1-800-IBM-SERV (1-800-426-7378).
In the U.S. and Canada, hardware service and support is available 24 hours a day, 7 days a week. In the
U.K., these services are available Monday through Friday, from 9 a.m. to 6 p.m.
Any reference to a Lenovo product, program, or service is not intended to state or imply that only that
Lenovo product, program, or service may be used. Any functionally equivalent product, program, or service
that does not infringe any Lenovo intellectual property right may be used instead. However, it is the user's
responsibility to evaluate and verify the operation of any other product, program, or service.
Lenovo may have patents or pending patent applications covering subject matter described in this
document. The furnishing of this document does not give you any license to these patents. You can send
license inquiries, in writing, to:
Lenovo (United States), Inc.
1009 Think Place - Building One
Morrisville, NC 27560
U.S.A.
Attention: Lenovo Director of Licensing
LENOVO PROVIDES THIS PUBLICATION “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS
OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT,
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some jurisdictions do not allow
disclaimer of express or implied warranties in certain transactions, therefore, this statement may not apply
to you.
This information could include technical inaccuracies or typographical errors. Changes are periodically
made to the information herein; these changes will be incorporated in new editions of the publication.
Lenovo may make improvements and/or changes in the product(s) and/or the program(s) described in this
publication at any time without notice.
The products described in this document are not intended for use in implantation or other life support
applications where malfunction may result in injury or death to persons. The information contained in this
document does not affect or change Lenovo product specifications or warranties. Nothing in this document
shall operate as an express or implied license or indemnity under the intellectual property rights of Lenovo
or third parties. All information contained in this document was obtained in specific environments and is
presented as an illustration. The result obtained in other operating environments may vary.
Lenovo may use or distribute any of the information you supply in any way it believes appropriate without
incurring any obligation to you.
Any references in this publication to non-Lenovo Web sites are provided for convenience only and do not in
any manner serve as an endorsement of those Web sites. The materials at those Web sites are not part of
the materials for this Lenovo product, and use of those Web sites is at your own risk.
Any performance data contained herein was determined in a controlled environment. Therefore, the result
obtained in other operating environments may vary significantly. Some measurements may have been
made on development-level systems and there is no guarantee that these measurements will be the same
on generally available systems. Furthermore, some measurements may have been estimated through
extrapolation. Actual results may vary. Users of this document should verify the applicable data for their
specific environment.
Intel and Intel Xeon are trademarks of Intel Corporation in the United States, other countries, or both.
Internet Explorer, Microsoft, and Windows are trademarks of the Microsoft group of companies.
Other company, product, or service names may be trademarks or service marks of others.
Important notes
Processor speed indicates the internal clock speed of the microprocessor; other factors also affect
application performance.
CD or DVD drive speed is the variable read rate. Actual speeds vary and are often less than the possible
maximum.
When referring to processor storage, real and virtual storage, or channel volume, KB stands for 1 024 bytes,
MB stands for 1 048 576 bytes, and GB stands for 1 073 741 824 bytes.
When referring to hard disk drive capacity or communications volume, MB stands for 1 000 000 bytes,
and GB stands for 1 000 000 000 bytes. Total user-accessible capacity can vary depending on operating
environments.
Maximum internal hard disk drive capacities assume the replacement of any standard hard disk drives
and population of all hard-disk-drive bays with the largest currently supported drives that are available
from Lenovo.
Maximum memory might require replacement of the standard memory with an optional memory module.
Each solid-state memory cell has an intrinsic, finite number of write cycles that the cell can incur. Therefore,
a solid-state device has a maximum number of write cycles that it can be subjected to, expressed as total
bytes written (TBW). A device that has exceeded this limit might fail to respond to system-generated
commands or might be incapable of being written to. Lenovo is not responsible for replacement of a
device that has exceeded its maximum guaranteed number of program/erase cycles, as documented in
the Official Published Specifications for the device.
Lenovo makes no representations or warranties with respect to non-Lenovo products. Support (if any) for
the non-Lenovo products is provided by the third party, not Lenovo.
Some software might differ from its retail version (if available) and might not include user manuals or all
program functionality.
Recycling information
Lenovo encourages owners of information technology (IT) equipment to responsibly recycle their
equipment when it is no longer needed. Lenovo offers a variety of programs and services to assist
equipment owners in recycling their IT products. For information on recycling Lenovo products, go
to:http://www.lenovo.com/recycling.
Risks that are posed by the presence of excessive particulate levels or concentrations of harmful gases
include damage that might cause the device to malfunction or cease functioning altogether. This
specification sets forth limits for particulates and gases that are intended to avoid such damage. The limits
must not be viewed or used as definitive limits, because numerous other factors, such as temperature
or moisture content of the air, can influence the impact of particulates or environmental corrosives and
gaseous contaminant transfer. In the absence of specific limits that are set forth in this document, you must
implement practices that maintain particulate and gas levels that are consistent with the protection of human
health and safety. If Lenovo determines that the levels of particulates or gases in your environment have
caused damage to the device, Lenovo may condition provision of repair or replacement of devices or
parts on implementation of appropriate remedial measures to mitigate such environmental contamination.
Implementation of such remedial measures is a customer responsibility.
Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits.
Lenovo is not responsible for any radio or television interference caused by using other than recommended
cables and connectors or by unauthorized changes or modifications to this equipment. Unauthorized
changes or modifications could void the user's authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)
this device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that might cause undesired operation.
This product has been tested and found to comply with the limits for Class A equipment according to
European Standards harmonized in the Directives in compliance. The limits for Class A equipment were
derived for commercial and industrial environments to provide reasonable protection against interference
with licensed communication equipment.
Warning: This is a Class A product. In a domestic environment this product may cause radio interference
in which case the user may be required to take adequate measures.
Deutschland:
Einhaltung des Gesetzes über die elektromagnetische Verträglichkeit von Betriebsmittein Dieses
Produkt entspricht dem „Gesetz über die elektromagnetische Verträglichkeit von Betriebsmitteln“ EMVG
(früher „Gesetz über die elektromagnetische Verträglichkeit von Geräten“). Dies ist die Umsetzung der
EU-Richtlinie 2014/30/EU (früher 2004/108/EC) in der Bundesrepublik Deutschland.
Dieses Gerät ist berechtigt, in Übereinstimmung mit dem Deutschen EMVG das EG-Konformitätszeichen
- CE - zu führen. Verantwortlich für die Konformitätserklärung nach Paragraf 5 des EMVG ist die Lenovo
(Deutschland) GmbH, Meitnerstr. 9, D-70563 Stuttgart.
Informationen in Hinsicht EMVG Paragraf 4 Abs. (1) 4: Das Gerät erfüllt die Schutzanforderungen nach
EN 55024 und EN 55022 Klasse A.
Nach der EN 55022: „Dies ist eine Einrichtung der Klasse A. Diese Einrichtung kann im Wohnbereich
Funkstörungen verursachen; in diesem Fall kann vom Betreiber verlangt werden, angemessene Maßnahmen
durchzuführen und dafür aufzukommen.“
Nach dem EMVG: „Geräte dürfen an Orten, für die sie nicht ausreichend entstört sind, nur mit besonderer
Genehmigung des Bundesministers für Post und Telekommunikation oder des Bundesamtes für Post und
Telekommunikation betrieben werden. Die Genehmigung wird erteilt, wenn keine elektromagnetischen
Störungen zu erwarten sind.“ (Auszug aus dem EMVG, Paragraph 3, Abs. 4). Dieses Genehmigungsverfahren
ist nach Paragraph 9 EMVG in Verbindung mit der entsprechenden Kostenverordnung (Amtsblatt 14/93)
kostenpflichtig.
Anmerkung: Um die Einhaltung des EMVG sicherzustellen sind die Geräte, wie in den Handbüchern
angegeben, zu installieren und zu betreiben.
Japanese Electrical Appliance and Material Safety Law statement (for detachable AC power cord)
JEITA harmonics guideline - Japanese Statement of Compliance for Products Less than or Equal
to 20A per phase
JEITA harmonics guideline - Japanese Statement of Compliance for Products More than 20A
This is electromagnetic wave compatibility equipment for business (Type A). Sellers and users need to pay
attention to it. This is for any areas other than home.
D E
danger statements 5 electrical input 10
data collection 123 electronic emission Class A notice 1142
DC power-supply Electronic Service Agent 140
LEDs 133 embedded hypervisor
DC power-supply LEDs 133 using 113
deassertion event, system-event log 135 enabling
device drivers 110 Features on Demand
devices, static-sensitive Ethernet software 114
handling 36 RAID software 114
diagnostic Enterprise X-Architecture technology 12
on-board programs, starting 139 environment 9
tools, overview 127 error codes and messages
diagnostic codes and messages IMM2 303
POST/UEFI 953 error messages 140
diagnostics error symptoms
program overview 137 general 141
diagnostics program hard disk drive 141
DSA Preboot 12 hypervisor flash device 143
X
U X-Architecture technology 12
UEFI
boot recovery jumper 162
undetermined problems 160
undocumented problems 125
United States FCC Class A notice 1142
Universal Serial Bus (USB) problems 157
UpdateXpress 99, 110
updating
DMI/SMBIOS data 119
firmware 99
Lenovo XClarity Administrator 115
server configuration 98
Systems Director 116
Systems Director, IBM 116
Universal Unique Identifier (UUID) 117
USB
connector 17, 19
USB hypervisor flash device
installing 69
removing 264
replacing 265
using
embedded hypervisor 113
integrated management module 110
Setup utility 103
the remote presence feature 111
Utility program
Advanced Settings 115
utility, Setup 100
starting 103
using 103