Model D4033
Type Inline,4stroke,liquid cooler
Cylinder 4 cylinder
Bore*Stroke(mm) 100*115
Compression Ratio 19:1
Displacement 3.61L
Aspiration Nature intake
1500rpm 33kw
Prime power(kw)/rev
1800/2000rpm 36kw
1500rpm 36.3kw
Standby power(kw)/rev
1800/2000rpm 39kw
Maximum no load speed: 1500rpm 1575rpm
Maximum no load speed: 1800rpm 1890rpm
Maximum no load speed: 2000rpm 2100rpm
Idle speed 600rpm
258g/kw.h
100% full consumption at power rating
9.25L/h
Oil Capacity 13L
Regulation method Mechanical speed
Starting Method Electric start
Net weight 380kgs
Over side (mm) 1035*694*1000
1.No operating time limited;
2.The average load factor shall not exceed 70% of the prime
power in 250 continuous hours
1 Prime power 3.The time of running at 100% Prime Power no more than 500h
each year
4.It allow overload 10% power of 1 hour every 12 hours ,and
the operating condition can't be more than 25 hours.
1.The time of running at standby power no more than 200h each
year, incloud the operating condition of running over 25 hours
in 100% load
2.The average load factor shall not exceed 80% of the standby
power in per 24 hours;
3.It does not have the ability of overload;
4.Starting the diesel engine without thermal process and
from start to accelerate to rated speed required to be
2 Standby power completed within 10s. When below ambient
temperature 5 ℃, naturally aspirated diesel engines
need to increase diesel preheat facility to ensure the
water temperature is above 30 ℃; And on the way
round when ambient temperature above 5 ℃. When
the ambient temperature below 10 ℃, the
turbocharged diesel engine need to increase diesel
preheat facility to ensure the water temperature is
above 30 ℃; And on the way round when ambient temperature
above 10 ℃.
NOTE: Do not run the engine out of the above power and operating conditions! ! !