Shenzhen Hawk Medical Instrument Co., Ltd. fai
HK-100 II Infusion pump
= Removable pump body
Convenient for cleaning
* Free flow protection
Ly The built-in flow stop feature helps to
reduce the risk of acckdental free low
* History Record
Event logs and alarm information can
be transferred to computer for review
* Rotatable pole clamp
Fixation on vertical pole or horizontal
bar
Infusion Pump Features
«+ Hstory records + Realtime dsplay
+ Various infusion modes tomeet diferent cles requirements = Compact and ight weight design
+ KVO, Bolus and Ant-bolus + Soft key design, easy for operate
« Anti-reverse rotation detection + Free-flow protection
+ Various visual and audble alarms + Double CPU ensuring safe infusion
+ Drop sensor (optional) + Removable pump body, convenient or cleaning
ri 1 7
. ct
. \ \
4 \
- | ANY
an
Shenzhen Hawk Medical Instrument Co., Ltd. _isorssss:2016is09001:2008/CE cenicato
Address:1st Floor, Building C,Jianyetai Industral Zone, E-malszhk@havkaedial on Fax: 0086-755-09151906
No.11 Minhuan Road, Fukang Community, Webs woawhawamedicaln Te 0086-755.69151901
Longhua Street, Longhua District, Shenzhen,
518109, Guangdong, PR.China®
HK-1001I Infusion pump howkmed
Infusion rate (0.11200 mh Increment: 0.04 mith
Infusion accuracy +£5% after correct calibration
Anpicable infusion set Various brands of standard infusion sets. including B.Braun, BD, Nipro etc.
Vole tobe infused (VT) _0-9999,99mi Increment: 0.01mith
Volume infused (0-36000 (mi)
KVO rate 0-10 min
Bolus rate Manual Bolus/Automatic Bolus: 0.1~1200 mifh
an Rate mode, Drip mode, Time mode, Body Weight mode, Drug library mode |
Intermittent mode, Dose mode
Purge rate 0.11200 mlh_Purge VTBI: 0-9999.99 mi
‘Air bubble detection Uttrasound sensor deteciton with 6 levels of airin line
(Occlusion pressure 413 adjustable occlusion levels
Use battery, Door open, Occlusion, Almost done, No operation, Infusion completion, Low Battery,
aa Battery exhausted, malfunction ete
‘Anti-bolus (diminishes the unwanted volume of Bolus after removal of occlusion)
Can change the flow rate and VTBI without stopping the infusion
Inteligent pressure detection alarm
‘Anti-reverse detection
History records more than 1300, can be transmitted to computer
Function Real time display the infusion rate dip rate, VTI, volume infused, time etc.
‘Standby function: 1 min = 88h 58min adjustable
‘Adjustable buzzer volume
Compatible with hospital HIS system
Removable pump body for easy cleaning
Keylock
Power supply DG: 12 1.2 AC: 100~ 240 V, 50/60 HZ
Battery Rechargeable Li Polymer battery, 7.4 V 1900 mAh
Battery charaing time 40 hours with power on, 3hours with power off
Battery operating tie More than § hours at 25 mith
Power consumption 35VA
Classification Class | type CF
Waterproof Pea
Dimension +445%100%120 mm (LxWxH)
Weight 1.4 Ko
Operating conditions “Temperature: 5€ - 40°C, Relative humidity: 10-95%, Atmosphere pressure: 86 — 106 KPa
“Transport conditions ‘Temperature: -20°C ~ 60%, Relative humidity: 10-95%, Atmosphere pressure: 60 - 106 kPa
‘Storage conditions ‘Temperature: -20'C ~ 45°C, Relative humidity: 10-95%, Atmosphere pressure: 50 - 106 kPa