0% found this document useful (0 votes)
227 views38 pages

H&M Store Interior Fit-Out Plan

This document provides project details for an H&M store interior tenant improvement project located at The Mall at Wellington Green in Wellington, Florida. It lists the project team including H&M as the tenant, Spinoso Real Estate Group as the landlord's representative, and Taylor Associates as the architect. It also notes the drawings comply with ADA accessibility requirements and applicable building codes.

Uploaded by

Fajar Ramadhan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
227 views38 pages

H&M Store Interior Fit-Out Plan

This document provides project details for an H&M store interior tenant improvement project located at The Mall at Wellington Green in Wellington, Florida. It lists the project team including H&M as the tenant, Spinoso Real Estate Group as the landlord's representative, and Taylor Associates as the architect. It also notes the drawings comply with ADA accessibility requirements and applicable building codes.

Uploaded by

Fajar Ramadhan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 38

JEFFREY

TAYLOR
INTERIOR TENANT IMPROVEMENT / FIT-OUT ARCHITECT

STORE NO. US326 572 NORTH BROADWAY


THE MALL AT WELLINGTON GREEN WHITE PLAINS, NEW YORK 10603

10300 W. FOREST HILL BOULEVARD TEL 914 289 0011

WELLINGTON, FL. 33414


PROJECT DIRECTORY CODE ANALYSIS LIST OF DRAWINGS

06.12.23 ISSUED FOR REVIEW

07.17.23 ISSUED FOR BIDS &


TENANT LANDLORD'S REPRESENTATIVE THESE PLANS COMPLY WITH THE PROVISION OF TITLE III OF THE "AMERICANS WITH DISABILITIES ACT" (ADA)

& APPROVALS
PUBLIC LAW 101-336, FOR HANDICAPPED ACCESSIBILITY FOR CUSTOMER AND EMPLOYEES.
H&M HENNES & MAURITZ SPINOSO REAL ESTATE GROUP

PERMIT
110 FIFTH AVENUE, 11TH FLOOR 112 NORTHERN CONCOURSE ALL WORK DONE UNDER THIS CONTRACT SHALL COMPLY WITH THE PROVISIONS OF THE SPECIFICATIONS,
NEW YORK, NY 10011 NORTH SYRACUSE, N.Y. 13212 DRAWINGS & CONSTRUCTION CRITERIA OF THE LANDLORD, AND SHALL SATISFY ALL APPLICABLE CODES,
TEL: (315) 425-1000 ORDINANCES, AND REGULATIONS OF ALL GOVERNING BODIES INVOLVED. ANY MODIFICATIONS TO THE
CONTACT: JIM HENNESSY CONTACTS: CONTRACT WORK REQUIRED BY SUCH AUTHORITIES SHALL BE PERFORMED BY THE GENERAL CONTRACTOR.
TITLE: CONSTRUCTION PROJECT MANAGER BRENDA SPARKS ALL PERMITS AND LICENSES NECESSARY FOR THE EXECUTION OF THE WORK SHALL BE SECURED AND PAID FOR
EMAIL: james.hennessy@hm.com TITLE:MANAGER - TENANT COORDINATION & LEASING BY THE GENERAL CONTRACTOR.
REVISED & ISSUED
TEL: (646) 732-0346 E-MAIL: bsparks@spinosoreg.com ISSUED
TEL: 315.802.6596 THESE PLANS ARE IN CONFORMANCE WITH THE FOLLOWING CODES:
ARCHITECT MEGHAN GREEN
TAYLOR ASSOCIATES
TITLE:TENANT COORDINATOR / CADD
2020 FBC - Building, 7th Edition
2018 INTERNATIONAL BUILDING CODE WITH AMENDMENTS DWG. # LIST OF DRAWINGS
E-MAIL: mgreen@spinosoreg.com 2020 FBC - Existing Building, 7th Edition
572 NORTH BROADWAY
WHITE PLAINS, NY 10603 TEL: 315.802.6582 2018 INTERNATIONAL EXISTING BUILDING CODE WITH AMENDMENTS
PHONE: (914) 289-0011 A-000 TITLE SHEET LIC # AR0015561
BUILDING DEPARTMENT 2020 FBC - Energy Conservation, 7th Edition
FAX (914) 289-0022 2018 INTERNATIONAL ENERGY CONSERVATION CODE WITH AMENDMENTS
WELLINGTON BUILDING DEPARTMENT 2020 FBC - Plumbing 7th Edition
A-010 GENERAL NOTES
CONTACT: JEFFREY T. TAYLOR
TITLE: R.A 12300 FOREST HILL BLVD. 2018 INTERNATIONAL PLUMBING CODE WITH AMENDMENTS
E-MAIL: jt@taylorarchitects.com WELLINGTON, FL. 33414 2020 FBC - Mechanical, 7th Edition
PHONE: 561-791-4000 2018 INTERNATIONAL MECHANICAL CODE EX-100A EXISTING CONDITION TAGGED PLAN
WEBSITE :https://www.wellingtonfl.gov NFPA 1 part of the 2020 FFPC, 7th edition EX-100B EXISTING CONDITION DIMENSION PLAN
2018 NFPA 1 WITH AMENDMENTS
Florida Fire Sprinkler Code EX-200 EXISTING STOREFRONT ELEVATIONS
2016 NFPA 13 FIRE SPRINKLER CODE
Florida Electric Code 2017
2017 NFPA 70 ELECTRIC CODE D-110 REMOVAL PLAN AREA 'A'
BUILDING DATA:
OCCUPANCY: EXISTING MALL TENANT LEASED SPACE D-111 REMOVAL PLAN AREA 'B'
USE GROUP: M - MERCANTILE
EXP. 2/28/2025
CONSTRUCTION TYPE: IIB A-110 EGRESS PLAN AREA 'A'
VENDOR LIST SPRINKLERD: YES (PER NFPA 13) A-111 EGRESS PLAN AREA 'B'
REVISION:
GROSS FLOOR AREA: 25,974 S.F. A-210 CONSTRUCTION PLAN AREA 'A'
HVAC SIGNAGE IFS / BOH LIGHTING OCCUPANT LOAD CALCS: A-211 CONSTRUCTION PLAN AREA 'B'
YORK INTERNATIONAL JOHNSON CONTROLS APEX SIGN GROUP WESCO NATIONAL RETAIL GROUP GROUND LEVEL A-310 CEILING PLAN AREA 'A'
5005 YORK DRIVE 2570 BLVD OF THE GENERALS, SUITE 225 2256 CITYGATE DRIVE, SUITE 100 A-311 CEILING PLAN AREA 'B'
NORMAN, OKLAHOMA 73069 NORRISTOWN, PA 19403 COLUMBUS, OH 43219 SALES AREA (GRADE FLOOR) + DISPLAY/POSTER & OPEN WINDOWS
TEL: 614.934.6403 + FITTING ROOMS: 1/60 = 21,010 S.F. / 60 = 351 OCC. A-410 FIXTURE PLAN AREA 'A'
CONTACT: DAVID W. ARPS CONTACT: MEGHAN LOWRY A-411 FIXTURE PLAN AREA 'B'
TITLE: NATIONAL ACCOUNTS SALES MANAGER TITLE: PROJECT MANAGER CONTACT: BEN FACTOR STOCK AREAS: 1/300 =1,222 S.F. / 300 = 4 OCC.
E: DAVID.W.ARPS@JCI.COM E: HM@APEXSIGNGROUP.COM TITLE: PROJECT MANAGER A-510 FINISH PLAN AREA 'A'
M: 414.687.7101 M: 610.209.7716 E: BFACTOR@WESCO.COM BOH AREA: 1/300 = 2,447 S.F. / 300 = 9 OCC.
M: 614.893.9891
A-511 FINISH PLAN AREA 'B' LEGEND & NOTES
STUCCO WALL FINISH ACT CEILING, DRYWALL CEILING VOID AREA: 1/100 = 1,295 S.F. / 100 = 13 OCC. A-600 STOREFRONT ELEVATIONS
AND WALLBOARD PRODUCTS A-700 PARTITION TYPES
MANUFACTURER: TOTAL OCCUPANT LOAD: 377 OCC.
STUC - O - FLEX INTERNATIONAL, INC.USG CORPORATION A-702 FIXTURE, CASHWRAP, MISC. DETAILS ISSUE DATE:
17639 NE 67TH COURT 550 W. ADAMS ST. EXIT REQUIREMENTS:
A-710 FLOORING, BASE & WALL PROTECTION DETAILS 06.12.23 FOR REVIEW & APPROVALS
REDMOND, WA. 98052 CHICAGO, IL 60661 NUMBER OF EXITS REQUIRED:
(2) EXITS FOR OCCUPANT LOAD OF 1 - 500 A-720 NOT USED 07.17.23 FOR BIDS & PERMITS
CONTACT: JIM KROCK CONTACT: JOHN FUNES (2) EXITS PROVIDED.
1800.305.1045 TITLE: USG / CGC ACCOUNT MANAGER A-730 FITTING ROOM AREA ENLARGED PLANS AND ELEVATIONS
1.425.885.5085 E: JFUNES@USG.COM EXIT WIDTH REQ'D.: A-740 NOT USED
1.425.869.0107 (FAX) M: 312.436.5841 TOTAL OCC. LOAD = 377 OCC.
EMAIL: info@stucoflex.com A-741 BOH MILLWORK DETAILS AND ELEVATIONS
377 OCC. LOAD X .2 = 76 LIN. IN
A-750 MISC. DETAILS
EXIT WIDTH PROVIDED: (1) 22'-3" (267") R.U.G. A-760 ELECTRICAL LEGEND AND NOTES
(1) 3'-6" (42") SINGLE DR. AT B.O.H.
A-761 ENLARGED MEP PLANS, DETAILS & NOTES
EXIT WIDTH REQ'D. = 76 LIN. IN. (6'-4") A-762 ENLARGED CASHWRAP ELEVATIONS (ELEC. SPECS.)
EXIT WIDTH PROVIDED = 309 LIN. IN. (25'-9") ARCH PROJECT NO.: 10835
A-763 PANEL SCHEDULES (PARTIAL) AND NOTES 2024
MIN. AISLE WIDTH REQ'D.: 36"
PRODUCT SEASON:
A-800 DOOR SCHEDULE SPACE NO.: 185
PLUMBING FIXTURE REQUIREMENTS: (INTERNATIONAL PLUMBING CODE) A-930 SPECIFICATIONS DRAWN BY: JTA
ADA COMPLIANCE NOTE: DISTANCE TO PUBLIC FACILITIES ): N/A A-931 SPECIFICATIONS SCALE:
PLUMBING FACILITIES WITHIN TENANT SPACE ARE FOR EMPLOYEE FACILITIES AS NOTED
LEASED PREMISES MUST COMPLY WITH TITLE III OF THE AMERICANS WITH DISABILITIES ACT MAX. NUMBER OF EMPLOYEES AT A TIME; 18 PEOPLE A-932 SPECIFICATIONS
(ADA) COMPLIANCE WILL INCLUDE, BUT NOT LIMITED TO THE DESIGN, CONSTRUCTION AND
/ OR ALTERATION OF THE LEASED PREMISES. UPON COMPLETION OF WORK, TENANT OR FIXTURE: REQUIRED: PROPOSED:
TENANTS ARCHITECT MUST SUPPLY TO LANDLORD A LETTER, SATISFACTORY TO THE WATER CLOSET (1) FOR 500 WOMEN +1FOR 500 MEN (1) FOR WOMEN + (1) FOR MEN IPS_1.1 CONSTRUCTION PLAN SHEET TITLE:
LANDLORD, STATING THAT THE LEASED PREMISES HAVE BEEN DESIGNED AND CONSTRUCTED LAVATORY (1) FOR 750 WOMEN+ 1FOR 750 MEN (1) FOR WOMEN + (1) FOR MEN
DRINKING FOUNTAIN (1) FOR 1,000 PEOPLE (1) HI-LOW DRINKING FOUNTAIN IPS_1.2 FIXTURE LAYOUT
IN ACCORDANCE AND ARE IN COMPLIANCE WITH THE ADA.
SERVICE SINK (1) (1) SERVICE SINK
IPS_1.3 LIGHTING PLAN TITLE SHEET
HAZARDOUS SUBSTANCE NOTE: FIRE ALARM WORK TO BE FILED UNDER
SEPARATE PERMIT APPLICATION BY G.C.
G.C. TO SUBMIT ANY POST PERMIT SET REVISIONS
TO D.O.B. AND PAY ALL RELATED FEES
IPS_1.4 WALL FINISH PLAN
IT IS THE RESPONSIBILITY PF THE TENANT AND THE TENANTS CONTRACTOR(S) WHEN IPS_1.5 FLOOR FINISH PLAN
PREPARING FOR AND PROCEEDING WITH CONSTRUCTION IN THE PREMISES, TO COMPLY SPRINKLER WORK TO BE FILED UNDER ALL STOREFRONT SIGNS TO BE FILED
UNDER SEPARATE PERMIT APPLICATION BY SIGN
WITH ALL REQUIREMENTS OF ALL APPLICABLE LAWS CONCERNING HAZARDOUS SEPARATE PERMIT APPLICATION BY G.C.
CONTRACTOR
IPS_1.6 STOREFRONT ELEVATIONS
SUBSTANCES. THE TENANT SHALL NOT PERMIT THE INSTALLATION OR USE OF ANY
HAZARDOUS SUBSTANCES IN ANY COMPONENT OF THE PREMISES DURING ITS TENANCY.

ALL MATERIALS USED IN THE CONSTRUCTION OF THIS SPACE MUST BE ASBESTOS FREE. AREA CALCULATIONS SCOPE OF WORK

THE MALL AT WELLINGTON GREEN


GENERAL NOTE:

STORE NO. US 326 - RED MOD

BLVD.WELLINGTON, FL. 33414


GROSS SQUARE FOOTAGE (UPPER LEVEL) · ALL WALLS TO BE PATCHED AND REPAIRED, AS REQD. SMOOTH AND LEVEL AND MADE READY TO RECEIVE NEW FINISHES.
SALES AREA: 21,010 SF · EXISTING PERIMETER WARDROBE FIXTURES THAT ARE TO REMAIN WILL BE PATCHED, REPAIRED & FULLY PAINTED. SEE FINISH

10300 W. FOREST HILL


STOCK AREA: 1,198 SF
BOH : 3,766 SF PLAN.
TOTAL: 25,974 SF · AFTER CONSTRUCTION ALL AREAS, INCLUDING TOILET ROOMS AND JANITOR CLOSETS, TO BE DEEP CLEANED THROUGHOUT.
MISSING FIXTURES (I.E. PAPER DISPENSERS, HOOKS, ROOM INDICATORS, ETC.), TO BE REPLACED AS REQD. COORDINATE WITH
H&M PROJECT MANGER.

2024
· SCHEDULED FOR LED RETROFIT. TURN OFF COVE LIGHTING, REMOVE HALOS.
STOREFRONT:
H&M (LOWER LEVEL) · EXISTING FAÇADE: PAINT WINDOW FRAMES H&M METAL COLOR PER FINISH PLAN.
STORE NO. US326 · ADD STUCCO TO ALL CLADDING AT STOREFRONT BULKHEAD, AS REQD. UNLESS OTHERWISE NOTED.
THE MALL AT WELLINGTON GREEN
10300 W. FOREST HILL BOULEVARD · REMOVE AND REPLACE 'H&M' LOGOS AS REQD.
WELLINGTON, FL. 33414
SALES AREA:
· ALL INTERIOR WALLS TO BE REFINISHED PER PLANS.
· REMOVE EXISTING WARDROBES, CHANNELS AND PORTION OF WALLS AS SHOWN, EXISTING PORTAL HEADERS AND LIGHTS TO REMAIN
(U.O.N.), PATCH AND REPAIRED, AS REQUIRED, PER REBUILD GUIDLINES.
· FRONT DISPLAY WINDOW: TRIM WALLS ON EACH SIDE TO OPEN IT UP, HAVE VISIBLE INTERIOR.
· CLOSE FRONT PORTAL, REMOVE LIGHTING AND WIRING AS REQD. PATCH ADJACENT WALLS AS REQD.
· REMOVE FREESTANDING WALL NEXT TO MEN’S ENTRANCE AND REPLACE WITH PODIUM AND MANNEQUINS.
· REMOVE LAST LIGHTBOX IN MEN’S, REPLACE WITH CURTAINS AND PLANTS.
· EXISTING CASHPOINT, BACKWRAP & POSTER AND FREE-STANDING WALL FIXTURES TO BE REMOVED AND REPLACED WITH NEW.
· ADD CLICK & COLLECT ROOM, AND RELATED EQUIPMENT AS REQD. NEAR WOMEN’S CP. SHEET NO:

A-000
· EXISTING LIGHTING IN PORTALS TO REMAIN, UNLESS OTHERWISE NOTED.
· EXISTING FLOORING & BASE TO REMAIN, CLEAN AND POLISH AS REQUIRED.
· EXISTING LIGHTING TO REMAIN 'AS-IS', UNLESS OTHERWISE NOTED.

* ·
·
·
ALL NEW SALES AREA FLOOR FIXTURE PACKAGE (UNLESS OTHERWISE NOTED) - WILL KEEP 2M & 3M IN GOOD CONDITION
REMOVE WALLS TO OPEN UP FITTING ROOM ENTRANCE, PUSH BACK WALL INTO DECO SPACE TO GET MORE SERVICE AREA SPACE.
ADD 3RD LAYER ITEMS IN WINDOWS (PER H&M), INTERIOR, BOH, FITTING ROOMS
· NEW MANNEQUINS THROUGHOUT. (PER H&M).
REV. NO:
FITTING ROOMS:
· EXISTING FITTING ROOM CABINS AND CURTAIN RODS TO REMAIN, BENCHES, CURTAINS AND MIRRORS TO BE REMOVED AND
NEW FITTINGS TO BE INSTALLED PER REBUILD PACKAGE STANDARDS.
· ALL INTERIOR WALLS TO BE REFINISHED PER PLANS.
· EXISTING FLOORING & BASE TO REMAIN, CLEAN AND POLISH AS REQUIRED.
· EXISTING CEILING LIGHTING TO REMAIN 'AS-IS'. NEW FITTING ROOM CABIN MIRRORS TO BE CIRCUITED TO EXISTING.
KEY PLAN (N.T.S.) NORTH LOCATION PLAN (N.T.S.) NORTH BOH:
D.O.B. NO:
· REPLACE FLOORING IN BOH PER PLAN
· STORE TEAM TO COORDINATE REMOVAL OF EXISTING VENDING MACHINE.
· REPLACE EXISTING REFRIGERATOR WITH NEW, (WITHOUT WATER DISPENSING FEATURE), PER H&M STANDARDS
· REPLACE EXISTING HI-LO DRINKING FOUNTAIN WITH NEW ADA FOUNTAIN WITH BOTTLE FILLER FEATURE
· ADD BUILT - IN RECYCLING STATION
· G.C. TO PROVIDE CONSTRUCTION BARRICADES AS REQUIRED PER LOCAL CODE AND MALL REQUIREMENTS.
GENERAL CONDITIONS GENERAL NOTES ABBREVIATIONS AND DEFINITIONS
ACT = ACOUSTICAL CEILING TILE
A. FIELD CONDITIONS ALL WORK IS TO CONFORM TO ALL APPLICABLE CODES AND REGULATIONS.
CONTRACTOR SHALL VERIFY ALL CONDITIONS AS WELL AS ALL DIMENSIONS AND CONDITIONS INDICATED IN THE AHJ = AUTHORITY HAVING JURISDICTION
DRAWINGS, PRIOR TO ACTUAL CONSTRUCTION. ANY VARIATION FROM CONDITIONS INDICATED IN THE THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL REQUIRED PERMITS AND APPROVALS PRIOR TO COMMENCEMENT OF WORK.
DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND OWNERS REPRESENTATIVE PRIOR TO AL OR ALUM. = ALUMINUM
COMMENCING WORK. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL REQUIRED INSPECTIONS AND CERTIFICATES. B.O. = BOTTOM OF
B. COORDINATION OF WORK THE CONTRACTOR WILL BECOME FAMILIAR WITH EXISTING CONDITIONS AND SHALL VERIFY EXISTING FIELD CONDITIONS IN THE FIELD B.O.H. = BACK OF HOUSE
THE CHARACTER AND SCOPE OF THE WORK ARE ILLUSTRATED BY THE WORKING DRAWINGS. CONTRACTOR PRIOR TO COMMENCEMENT OF THE WORK, AND SHALL REPORT ANY DISCREPANCIES BETWEEN THE DRAWINGS AND FIELD CONDITIONS
CL = CENTER LINE
SHALL CAREFULLY EXAMINE ALL THE DRAWINGS AND BE RESPONSIBLE FOR THE PROPER INSTALLATION OF HIS TO THE ARCHITECT.
WORK AND PROPER CONSIDERATION FOR THE WORK OF OTHERS AND EXISTING BUILDING CONSTRUCTION. DO
NOT PLACE DUCTS, PIPING, CONDUIT OR ANY OBSTRUCTION SO AS TO IMPAIR REQUIRED CEILING HEIGHTS AND FOR GENERAL CONDITIONS REFER TO AIA DOCUMENT A107 2007.
C.H. = CEILING HEIGHT JEFFREY
CLEARANCE FOR LIGHTING FIXTURES, ETC. CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF
EXISTING ADJACENT TENANT(S) AND BUILDING FACILITIES. CONTRACTOR TO COORDINATE WITH LANDLORD AND
OBTAIN AND FOLLOW BUILDING RULES AND REGULATIONS FOR CONSTRUCTION.
ALL WORK TO BE WARRANTED FOR A PERIOD NO LESS THAN ONE YEAR.
CLG.
COL.
=
=
CEILING
COLUMN
TAYLOR
THE CONTRACTOR SHALL COORDINATE ALL WORK PROCEDURES WITH REQUIREMENTS OF LOCAL AUTHORITIES AND BUILDING
C. BUILDING CODES AND REGULATIONS MANAGEMENT.
CONST. = CONSTRUCTION ARCHITECT
ALL WORK SHALL CONFORM TO ALL CODES AND REGULATIONS. CONTRACTOR SHALL FILE, PAY FOR, AND CONTR. = CONTRACTOR
OBTAIN ALL REQUIRED PERMITS TO PERFORM THE WORK. CONTRACTOR SHALL OBTAIN ALL REQUIRED ALL ELECTRICIANS AND PLUMBERS INVOLVED IN THE WORK ARE TO BE LICENSED AND BONDED.
APPROVALS FROM GOVERNMENTAL AGENCIES INVOLVED PRIOR TO FINAL PAYMENT. APPROVALS TO OCCUPY CS = COMPOSITE SHEET
THE SPACE BY LOCAL BUILDING OFFICIALS SHALL BE OBTAINED. ELECTRICAL WORK SHALL BE FILED SEPARATELY BY THE ELECTRICAL SUBCONTRACTOR. 572 NORTH BROADWAY
C.T. = CERAMIC TILE
WHITE PLAINS, NEW YORK 10603
D. INSURANCE DEMOLITION IS TO BE PERFORMED IN AN ORDERLY MANNER, PER THE RESTRICTIONS, REGULATIONS, AND HOURS SET BY THE BUILDING D.C.L. = DESIGN CONTROL LINE
1. CONTRACTOR SHALL SECURE, PAY FOR, AND MAINTAIN DURING CONSTRUCTION FIXTURING WORK WITHIN MANAGEMENT. DEBRIS IS TO BE DISCARDED OFF SITE IN A PROPER MANNER AND NOT BE ALLOWED TO ACCUMULATE IN THE WORK AREA.
LEASED PREMISES, ALL OF THE INSURANCE POLICIES REQUIRED AND IN THE AMOUNTS AS SET FORTH HEREIN. EA. = EACH
TEL 914 289 0011
CONTRACTOR SHALL NOT COMMENCE ANY WORK UNTIL ALL REQUIRED INSURANCE HAS BEEN OBTAINED DIMENSIONS GIVEN ARE TO FINISH SURFACES UNLESS NOTED OTHERWISE. EQUIP. = EQUIPMENT
AND CERTIFICATES OF SUCH INSURANCE HAVE BEEN DELIVERED TO THE LANDLORD AND TENANT. LANDLORD
AND H & M, HENNES & MAURITZ, LP, 110 5TH AVENUE, NEW YORK, NY 10011 MUST BE NAMED AS THE CONTRACTOR SHALL LAY OUT HIS OR HER OWN WORK, AND SHALL FURNISH ALL DIMENSIONS REQUIRED FOR OTHER TRADES (E)/EXIST./EX'G. = EXISTING
"ADDITIONAL INSURED". THIS WORDING NEEDS TO BE INCLUDED: THE FOLLOWING PARTIES AS ADDITIONAL (PLUMBING, ELECTRICAL, ETC...)
INSURED: ALL PARTIES INCLUDING H & M, HENNES & MAURITZ, LP, 110 5TH AVENUE, NEW YORK, NY 10011 FA = FIRE ALARM
RESPECTED OFFICERS, AGENTS, EMPLOYEES AND AFFILIATES OF ALL OF THE AFOREMENTIONED PARTIES. AN G.C. TO CHECK WITH LANDLORD FOR TYPE OF CONNECTIONS & POINT ATTACHMENT TO EXISTING STRUCTURE AND SLAB PRIOR TO FC = FILE CABINET
AFFILIATE SHALL BE DEFINED AS ANY CORPORATE ENTITY WHICH IS A PARENT OR SUBSIDIARY OF ANY OF THE PERFORM WORK.
AFOREMENTIONED PARTIES, OR WHICH HAS THE SAME PARENT CORPORATION AS ANY OF THE F.E. = FIRE EXTINGUISHERS
AFOREMENTIONED PARTIES. CERTIFICATES OF INSURANCE SHALL COVER ALL WORK PERFORMED BY G.C. G.C. TO COORDINATE WITH ALL H & M VENDORS AND SUPERVISORS AT JOB SITE.
AND EACH OF HIS SUBCONTRACTORS AND ALL MAJOR SUPPLIERS. FIN. = FINISH OR FINISHED
G.C. AND HIS FLOOR CONTRACTORS TO INSPECT FLOOR AT TIME OF H & M POSSESSION OF SPACE FROM LANDLORD & ADVISE H & M OF =
2. GENERAL CONTRACTOR'S AND SUBCONTRACTORS' REQUIRED MINIMUM COVERAGE AND LIMITS OF LIABILITY: ANY PROBLEMS OR DEFICIENCIES. F&I FURNISHED & INSTALLED
F.R. = FIRE RATED OR RETARDANT
A. WORKMEN'S COMPENSATION INSURANCE - IN ACCORDANCE WITH THE GOVERNING LAWS WITH A LIMIT OF G.C. TO SCHEDULE H&M VENDOR DELIVERIES WITH H&M PROJECT MANAGER.
NOT LESS THAN $1,000,000. AND ANY INSURANCE REQUIRED BY ANY EMPLOYEE BENEFITS ACTS, ETC. AS WILL G.C. = GENERAL CONTRACTOR

B.
PROTECT THE CONTRACTOR AND SUBCONTRACTORS FROM ANY AND ALL LIABILITY.

CONTRACTOR SHALL PAY FOR AND FURNISH TO TENANT AND LANDLORD, CERTIFICATES OF INSURANCE WHICH
LOCAL LAWS (HANDICAPPED ACCESS) GYP. BD.
HM
=
=
GYPSUM WALLBOARD
HOLLOW METAL
WILL PROTECT SAID CONTRACTOR FROM CLAIMS (i) UNDER WORKMAN'S COMPENSATION ACTS AND OTHER
EMPLOYEE BENEFIT ACTS, WITH LIMITS OF NOT LESS THAN $5,000,000.; (ii) FOR DAMAGES BECAUSE OF BODILY H.C. = HANDICAPPED
PROPOSED WORK TO COMPLY WITH APPLICABLE REQUIREMENTS OF LOCAL LAWS FOR HANDICAPPED ACCESS.
INJURY, (INCLUDING DEATH) TO HIS EMPLOYEES AND ALL OTHERS, WITH THE LIMITS OF $5,000,000 PER PERSON HR. = HOUR
AND $5,000,000. PER OCCURRENCE; AND (iii) FOR DAMAGES TO PROPERTY WITH LIMITS OF $5,000,000. WHICH TOILET ROOMS TO COMPLY WITH THE APPLICABLE REQUIREMENTS OF LOCAL LAWS FOR HANDICAPPED ACCESSIBILITY.
ARISE OUT OF OR RESULT FROM THE CONTRACTOR'S WORK UNDER THIS CONTRACT WHETHER SUCH WORK L.L. = LEASE LINE
(INCLUDING OPERATION OF MOTOR VEHICLES) BE BY HIMSELF OR OTHERS DIRECTLY OR INDIRECTLY EMPLOYED BY ACCESSIBLE ROUTES TO BE FURNISHED, PROVIDING A MINIMUM OF 32 INCHES OF WIDTH AT DOORWAYS.
EITHER; AND BUILDERS RISK INSURANCE IN THE FULL AMOUNT OF THE CONTRACT SUM. EXCESS / UMBRELLA LKR = 3-TIER OR 6-TIER LOCKER LIC # AR0015561
LIABILITY $10,000,000 EACH OCCURRENCE AND $10,000,000 AGGREGATE. EMERGENCY WARNING SYSTEMS SHALL INCLUDE BOTH AUDIBLE AND VISUAL ALARMS AS PER CODE REQUIREMENTS. MATL. = MATERIAL
C. CONTRACTOR SHALL ALSO FURNISH GENERAL LIABILITY INSURANCE AS FOLLOWS - $1,000,000 EACH PROPOSED STORAGE FACILITIES SUCH AS CABINETS, SHELVES, CLOSETS, AND DRAWERS SHALL COMPLY WITH APPLICABLE REQUIREMENTS OF MAX. = MAXIMUM
OCCURRENCE AND $2,000,000 GENERAL AGGREGATE. H.C. ACCESSIBILITY OF LOCAL LAWS :
MIN. = MINIMUM
3. INDEMNIFICATION - TO THE FULLEST EXTENT PERMITTED BY LAW, THE CONTRACTOR SHALL INDEMNIFY AND A. CLEAR FLOOR SPACE OF A MINIMUM OF 30 INCHES BY 48 INCHES SHALL BE FURNISHED FOR APPROACH TO ALL STORAGE FACILITIES. MIR. = MIRROR OR MIRRORED
HOLD HARMLESS THE LANDLORD, TENANT, AND THE ARCHITECT AND THEIR AGENTS AND EMPLOYEES FROM
AND AGAINST ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES, INCLUDING BUT NOT LIMITED TO ATTORNEY'S B. STORAGE SPACES SHALL COMPLY WITH AT LEAST ONE OF THE REACH RANGES SPECIFIED IN H.C. APPLICABLE ACCESSIBILITY CODES. MPSS = MIRROR POLISHED STAINLESS STEEL
FEES ARISING OUT OF OR RESULTING FROM THE PERFORMANCE OF THE WORK, FURNISHED THAT ANY SUCH CLOTHES RODS SHALL
BE A MAXIMUM OF 54 INCHES OFF THE FLOOR. MTL. = METAL
CLAIM, DAMAGE, LOSS, OR EXPENSE (1) IS ATTRIBUTABLE TO BODILY INJURY, SICKNESS, DISEASE, OR DEATH,
OR TO INJURY OR TO DESTRUCTION OF TANGIBLE PROPERTY (OTHER THAN THE WORK ITSELF) INCLUDING N.I.C. = NOT IN CONTRACT
THE LOSS OF USE RESULTING THEREFROM, AND (2) IS CAUSED IN WHOLE OR IN PART BY A NEGLIGENT ACT C. HARDWARE FOR STORAGE FACILITIES SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR
OR OMISSION OF THE CONTRACTOR, ANY SUBCONTRACTORS, ANYONE DIRECTLY OR INDIRECTLY EMPLOYED TWISTING OF THE WRIST. THK. = THICK
BY ANY OF THEM MAY BE LIABLE, REGARDLESS OF WHETHER OR NOT IT IS CAUSED IN PART BY A PARTY
N.T.S. = NOT TO SCALE

E.
INDEMNIFIED HEREUNDER.

LIEN WAIVERS AND SWORN AFFIDAVITS


TENANT'S SAFETY PLAN O.C. = ON CENTER
EXP. 2/28/2025

CONTRACTOR SHALL FURNISH WITHIN 30 DAYS AFTER COMPLETION, FINAL WAIVERS OF LIEN FOR ALL WORK OPP. = OPPOSITE
PERFORMED AS WELL AS ALL SUBCONTRACTORS AND MAJOR SUPPLIERS
REVISION:
GENERAL P.C. = POWDER COAT
F. CERTIFICATE OF OCCUPANCY ALL WORK TO BE DONE IN ACCORDANCE WITH THE LOCAL BUILDING CODE, AND REGULATIONS OF ALL OTHER AGENCIES HAVING PLYWD. = PLYWOOD
CONTRACTOR WILL FURNISH TENANT AND LANDLORD WITH A COPY OF THE CERTIFICATE OF OCCUPANCY. JURISDICTION.
PVM = PEOPLE VIEW MONITOR
G. QUALITY STANDARDS STRUCTURAL
ALL SUCH WORK SHALL BE PERFORMED IN A FIRST CLASS WORKMANLIKE MANNER AND SHALL BE IN GOOD AND RB = RUBBER BASE
USEABLE CONDITION AT THE DATE OF COMPLETION THEREOF. CONTRACTOR SHALL GUARANTEE ALL WORK A. CONTRACTOR TO FURNISH ADEQUATE TEMPORARY BRACING AND SHORING WHEREVER ANY STRUCTURAL WORK IS INVOLVED.
REF = REFERENCE
PERFORMED TO BE FREE FROM ANY AND ALL DEFECTS IN WORKMANSHIP AND MATERIALS FOR ONE (1) YEAR B. ALL DEMOLITION OPERATION, REPAIR OPERATIONS, AND ALTERATION OPERATIONS TO BE DONE IN ACCORDANCE WITH
FROM THE DATE ALL CONSTRUCTION PUNCH LIST ITEMS HAVE BEEN COMPLETED AND ACCEPTANCE HAS BEEN FBC - 2020 REQ'D. = REQUIRED
CONFIRMED IN WRITING BY THE TENANT REPRESENTATIVE. CONTRACTOR SHALL BE RESPONSIBLE FOR THE
REPLACEMENT OR REPAIR WITHOUT ANY ADDITIONAL CHARGE FOR ANY AND ALL WORK DONE OR FURNISHED MEANS OF EGRESS REQ'TS. = REQUIREMENTS
WHICH SHALL BECOME DEFECTIVE WITHIN THIS ONE (1) YEAR PERIOD. THE CORRECTION OF SUCH WORK SHALL RSP = RIGID SHEET PLASTIC
INCLUDE, WITHOUT ADDITIONAL CHARGE, ALL EXPENSES AND DAMAGES IN CONNECTION WITH SUCH REMOVAL, ALL EXISTING MEANS OF EGRESS FOR TENANTS OF THE BUILDING TO BE MAINTAINED CLEAR AND FREE OF ALL OBSTRUCTIONS, SUCH AS
REPLACEMENT, OR REPAIR OF ANY PART OF THE WORK WHICH MAY BE DAMAGED OR DISTURBED THEREBY. ALL BUILDING MATERIALS, TOOLS, ETC. R.U.G. = ROLL UP GRILLE
WARRANTIES OR GUARANTEES AS TO MATERIALS OR WORKMANSHIP ON OR WITH RESPECT TO TENANT'S WORK
SHALL BE CONTAINED IN THE CONTRACT OR SUBCONTRACT WHICH SHALL BE SO WRITTEN THAT SUCH FIRE SAFETY SC = SAFETY CABINET ISSUE DATE:
GUARANTEES OR WARRANTEES SHALL INSURE TO THE BENEFIT OF BOTH LANDLORD AND TENANT, AS THEIR
A. ALL BUILDING MATERIALS STORED AT CONSTRUCTION AREA, AND/ OR GENERAL CONTRACTOR. SHT. = SHEET 06.12.23 FOR REVIEW & APPROVALS
RESPECTIVE INTEREST APPEAR AND CAN BE DIRECTLY ENFORCED BY EITHER. B. ALL MATERIALS TO BE STORED IN AN ORDERLY FASHION.
C. ALL FLAMMABLE MATERIALS TO BE KEPT AWAY FROM HEAT. SIM. = SIMILAR 07.17.23 FOR BIDS & PERMITS
H. RUBBER WHEEL CARTS D. ALL FLAMMABLE MATERIALS TO BE USED AND STORED IN AN ADEQUATELY VENTILATED SPACE.
CONTRACTOR'S CARTS, EQUIPMENT BOXES, ETC., MUST BE EQUIPPED WITH RUBBER WHEELS. E. ALL ELECTRICAL POWER TO BE SHUT-OFF WHERE THERE ARE EXPOSED CONDUITS. SM. = SPECIAL MIRROR
F. ALL ELECTRICAL POWER IN THE CONSTRUCTION AREA TO BE SHUT OFF AFTER WORKING HOURS.
G. CONTRACTOR, AT ALL TIMES, TO MAKE SURE THERE ARE NO LEAKS OF NATURAL GAS IN BUILDING, OR ANY FLAMMABLE GAS USED IN SC WD = SOLID CORE WOOD DOOR
J. FIRE EXTINGUISHERS
EXISTING LOCATIONS TO BE MAINTAINED, IF IT ACCOMMODATES NEW LAYOUT WHERE APPLICABLE. CONSTRUCTION. S.S. = STAINLESS STEEL
CONTRACTOR TO VERIFY REQUIRED NUMBER AND LOCATION OF ANY ADDITIONAL EXTINGUISHERS REQUIRED BY
FIRE DEPARTMENT AND FURNISH AND INSTALL SAME. INSTALL AFTER FIXTURING. DUST CONTROL STD. = STANDARD
A. DEBRIS, DIRT, AND DUST TO BE KEPT TO A MINIMUM, AND BE CONFINED TO THE IMMEDIATE CONSTRUCTION AREA. TEN. = TENANT
K. RESPONSIBILITY FOR MATERIALS ON SITE
CONTRACTOR SHALL BE RESPONSIBLE FOR ALL MATERIALS SHIPPED TO THE JOB SITE INCLUDING MATERIALS B. CONTRACTOR TO ISOLATE CONSTRUCTION AREA FROM OCCUPIED BUILDING AREAS BY MEANS OF TEMPORARY PARTITIONS OR HEAVY TBS = TO BE SCHEDULED
FURNISHED BY OTHERS. COST OF ALL MISSING MATERIALS WILL BE DEDUCTED FROM THE CONTRACT PRICE AND WEIGHT DROP CLOTHES.
FINAL PAYMENT. CONTRACTOR TO CHECK ALL INVOICES AT TIME SHIPMENT IS RECEIVED AND NOTIFY TENANT THK. = THICK ARCH PROJECT NO.: 10835
REPRESENTATIVE OF ANY DISCREPANCIES, DAMAGED OR MISSING ITEMS WITHIN 48 HOURS OF DELIVERY. C. DEBRIS, DIRT, AND DUST TO BE CLEANED UP AND CLEARED FROM BUILDING PERIODICALLY TO AVOID ANY EXCESSIVE ACCUMULATION.
T.O. = TOP OF PRODUCT SEASON: 2024
NOISE AFTER HOURS
L. RUBBISH REMOVAL U.O.N. = UNLESS OTHERWISE NOTED SPACE NO.: 185
CONTRACTOR SHALL BE RESPONSIBLE FOR DAILY REMOVAL FROM THE PROJECT, ALL TRASH, RUBBISH AND
A. CONSTRUCTION OPERATIONS WILL BE CONFINED TO NORMAL WORKING HOURS: 8 A.M. TO 5 P.M., MONDAYS THROUGH FRIDAYS, U.S. = UNDERSIDE DRAWN BY: JTA
SURPLUS MATERIALS RESULTING FROM CONSTRUCTION, FIXTURING AND MERCHANDISING OF THE DEMISED EXCEPT LEGAL HOLIDAYS.
PREMISES. COORDINATE REMOVAL OF DEBRIS WITH SHOPPING CENTER MGMT. SCALE:
V.I.F. = VERIFY IN FIELD AS NOTED
B. CONTRACTOR TO OBTAIN PERMITS AND THE WRITTEN CONSENT OF ALL PARTIES AFFECTED BY HIS WORKING DURING OTHER THAN
REGULAR HOURS. COORDINATE WITH MALL MANAGEMENT/LANDLORD'S REPRESENTATIVE. w/ = WITH
WP = WALL PANEL SHEET TITLE:
ACCESSIBILITY CLEARANCES AS BUILT DRAWINGS SYMBOLS GENERAL NOTES
H&M CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING FULL "AS-BUILT" ROOM NAME
12 IN (305 MM) MIN X DOOR TAG
CONSTRUCTION DOCUMENTS TO H&M PROJECT ARCHITECT IS DIRECTION UPON
WHERE LATCH + CLOSER PULL SIDE RM # ROOM TAG
CONSTRUCTION COMPLETION AS A REQUIREMENT FOR PROJECT CLOSE-OUT
PULL SIDE ARE FURNISHED CEILING TAG
AFF
PUSH SIDE X FINISH TAG
PROJECT CLOSE OUT FINISH
1525 mm
60" MIN

18" MIN
1220 mm
48" MIN

Y
445 mm X COLUMN TAG ELEVATION TAG

THE MALL AT WELLINGTON GREEN


X PROJECT CLOSE OUT SHOULD OCCUR WITHIN 60-90 DAYS AFTER THE STORE OPENS. FINAL
REQUISITION FOR PAYMENT WILL BE MADE TO THE CONTRACTOR WHEN ALL CLOSE OUT

STORE NO. US 326 - RED MOD

BLVD.WELLINGTON, FL. 33414


PAPERWORK IS IN A COMPLETE CLOSE OUT FILE TO INCLUDE; REVISION TAG
X
X

10300 W. FOREST HILL


- SIGNED OFF PUNCH LISTS FROM H&M AND LANDLORD.
- FINAL LIEN WAIVERS FROM G.C. AND ALL SUBCONTRACTORS.
NOTE: X = 36 IN (915 MM) MINIMUM IF Y = 60 IN (1525 MM); - AS BUILT DRAWINGS X KEYNOTE TAG PARTITION TYPE
X = 42 IN (1065 MM) MINIMUM IF Y = 54 IN (1370 MM). - AIR
NOTBALANCE
USED REPORT BY INDEPENDENT AIR BALANCING COMPANY WHICH HAS BEEN
REVIEWED AND APPROVED BY THE PROJECT MECHANICAL ENGINEER.
- CERTIFICATE OF OCCUPANCY AND ALL INSPECTION SIGN OFF CARDS. X FIXTURE TAG
- ALL EQUIPMENT OPERATION AND MAINTENANCE MANUALS.

2024
(A) FRONT APPROACH, PULL SIDE (B) FRONT APPROACH, PUSH SIDE (C) HINGE APPROACH, PULL SIDE - SWORN STATEMENT OF CONTRACTORS COSTS FORM
- LIST OF ALL SUBCONTRACTORS WITH CONTACT NAMES AND PHONE NUMBERS DETAIL AREA
12 IN (305 MM) MIN - CHANGE ORDER ANALYSIS FORM NUMBER DETAILED
WHERE LATCH + CLOSER - CONTRACTORS CERTIFICATE OF INSURANCE X
ARE FURNISHED
24" MIN 24" MIN
54" MIN 610 mm 610 mm X X X
1370 mm
PUSH SIDE
PULL SIDE
PUSH SIDE
LIST OF SUBMITTALS/SHOP X
SHEET
LOCATOR

DRAWINGS (WHERE APPLICABLE)


1220 mm
48" MIN
1065 mm
42" MIN

1065 mm
42" MIN
ELEVATION SECTION SECTION DETAIL PLAN DETAIL REVISION
22" MIN
CLOUD
560
1. GENERAL CONTRACTOR AND SUB CONTRACTOR TO FURNISH SUBMITTALS/ SHOP
DWGS. FOR REVIEW & APPROVALS TO ARCHITECT, TENANT, LANDLORD, DEPT. OF BLDG.
AND ALL REQUIRED AUTHORITIES AND AGENCIES. REFER TO S.M.E.P. DOCUMENTS FOR
NOTE: * = 48 IN (1220 MM) NOTE: * = 54 IN (1370 MM) SPECIFIC SHOP DRAWINGS REQUIRED FOR THIS PROJECT.
NOTE: * = 48 IN (1220 SHEET NUMBER
MINIMUM IF DOOR HAS MINIMUM IF DOOR HAS CLOSER. MM) MINIMUM IF DOOR SHEET NO:
BOTH A LATCH AND SIGNAGE QUARRYCAST
HAS BOTH A CLOSER.

A-010
CLOSER. H.V.A.C. UNITS & CONTROLS INTERIOR WOODWORK (B.O.H. MILLWORK) DISCIPLINE DESIGNATOR SHEET TYPE
DUCT LAYOUT & CONNECTIONS STRUCTURAL STEEL FRAMING (ARCH.,PLUMB., ELEC., (CONSTRUCTION
(D) HINGE APPROACH, PUSH SIDE (E) LATCH APPROACH, PULL SIDE (F) LATCH APPROACH, PUSH SIDE FIRE ALARM STEEL DOORS/ FRAMES ETC.) DESCRIPTION)
SPRINKLER ROLL UP GRILLES

X-XXX
ANSI FIG.404.2.4.1 ACCESS PANEL GLAZING
MANEUVERING CLEARANCE AT SWINGING DOORS STOREFRONT ACOUSTICAL CEILING TILE & GRID
ESCALATORS (WHERE APPLICABLE) TOILET COMPARTMENTS
ELEVATORS (WHERE APPLICABLE) STEEL LOCKERS REV. NO:
DOOR HARDWARE TOILET ACCESSORIES
SMOKE BAFFLE CONCRETE MIX * NOTES:
HANDRAILS/ GUARDRAILS REINFORCING BAR SEQUENCE NUMBERS
STAIR CALC. FOR PILE DESIGN ANY DRAWING THAT IS CHANGED AFTER THE (NUMBER OF
BRAKE METAL PLUMBING FIXTURES FIRST ISSUE WILL HAVE A DELTA WITH SEQUENCE DRAWINGS IN
710 815 915
28" 32" 36"

RECEPTACLES LIGHTING FIXTURES # ( ) AND 'REVISION SEQUENCE' NUMBER WILL SEQUENCE)


ELECTRICAL DISTRIBUTION DISCONNECT/ SWITCHES MATCH DELTA #. SEQUENCE NUMBERS
DIFFUSERS/ GRILLES GENERAL OR FLOOR
DELTA NUMBERS WILL SHOW ON APPLICABLE LEVEL
30" MIN REVISED SHEETS IN TITLE BLOCK COLUMN. (CELLAR, FIRST FLOOR
D.O.B. NO:
760 2. G.C. TO SUBMIT CEILING COORDINATION PLAN w/ LOCATION OF ALL DEVICES
(LIGHTING, INT. SIGNAGE, LIT. NAVIGATION, DIFFUSERS, ACCESS PANELS, SPRINKLER HEADS, SECOND FLOOR, ETC.)
ETC.) FOR APPROVALS IF A DRAWING IS NOT REVISED, BUT PUBLISHED
WITH NEW REVISED SHEET(S), THE REVISION
(A) BEFORE REMOVAL OF CABINETS AND BASE (B) CABINETS AND BASE REMOVED AND HEIGHT NUMBER WILL NOT CHANGE ON THAT SHEET
ALTERNATIVES NOT LIMITED TO THIS LIST EVEN THOUGH THE NEW REV APPEARS ON THE
TITLE BLOCK COLUMN AT BOTTOM.
LOUNGE SINK
EXIST. PLAN KEY NOTES SYMBOL LEGEND
1 8" WIDE X 2" DEEP NEUTRAL PIER WITH BLACK CHANNEL REVEAL (TYP.) 15 LIGHTBOX (9'-2" WIDE), WITH PERFORATED METAL PANELS ON SIDES; TOP @ +2'-5",
SYMBOL LEGEND SYMBOL LEGEND
RECESSED SINGLE SLOTTED STDS. @ 2'-0 1/2" O.C.
BOTT. @ +9'-7" AFF SYMBOL DESCRIPTION FLUSH RECESSED SINGLE SLOTTED STANDARDS IN G.B. PERIMETER
2 8" WIDE WHITE METAL SASH WITH 1/2" TK. GLASS (FULL HT. BUTT-JOINTS, (6" H. FR WALLS FROM +8" TO 7'-8" AFF
BASE, TOP @ +11'-4" AFF) 16 FLUSH RECESSED H&M ILLUMINATED SIGN -- DENOTES DRAWING NOTE ( SEE THIS DRAWING )
M LOCATION OF MIRROR - SEE TAG FOR DESCRIPTION.
3 POLISHED WHITE METAL CLADDING AT MALL SIDE OF R.U.G. (TYP.) 17 GYP. BD. SHOW WINDOW SOFFIT @ +11'-5" AFF DENOTES DEMISING PARTITION.
DENOTES INTERIOR PARTITIONS TO REMAIN ( SEE THIS DRAWING ) EXIT SIGNAGE
4 PAINTED FINISH AT SALES AREA SIDE OF R.U.G. (TYP.) 18 WHITE BREAK METAL FINISH RETURNS TO DBL. DOOR JAMBS

5 LINE OF R.U.G. LEASED AREA

6 2'-0" H. PENDANT MOUNTED H&M ILLUMINATED SIGN


19 LINE OF RECESSED LIGHT COVE (TYP.)
RECESSED
DISPLAY
RECESSED
DISPLAY
EXISTING CONDITIONS GENERAL NOTES & LIMITING FIELD CONDITIONS:
JEFFREY
20 MIRROR LOCATION (TYPICAL AS SHOWN). CABINET CABINET

7 GYP. BD. ENTRY PORTAL @ +11'-4" AFF


21 (3) REGISTER CASH-DESK WITH BACKWRAP
FREE-STANDING
DISPLAY
PANEL WITH
SLOTTED
STANDARDS
PERIMETER / FREE STANDING DISPLAY FIXTURES
· EXISTING 'LOOSE' SALES AREA FIXTURES ARE NOT SHOWN AND ARE TO BE VERIFIED TAYLOR
IN FIELD.
8 TOP OF STOREFRONT AND MALL SOFFIT @ + 13'-6" AFF
22 (1) ADA CASH-WRAP
·
·
ALL PERIMETER FIXTURE AND FITTING ROOM LAYOUTS ARE AS SHOWN.
8" WIDE, WHITE STOREFRONT GLAZING SASH WITH 1/2" BUTT JOINTED GLASS.
ARCHITECT
9 SENSORMATIC PEDESTAL (TYP.) NON-RECESSED FIXTURE
PERIMETER FRAMES 6" H. BRUSHED S.S. BASE WITH 2" RECESS, TOP OF STOREFRONT WINDOWS AND
DISPLAY CAB.
10 BOTTOM OF GYP. BD. CURTAIN WALL @ +10'-10" 22 SURFACE MOUNTED LIGHTBOX ABOVE BACKWRAP. MALL SOFFIT@ +11'-4" AFF
11 EMERGENCY RELEASE FRO R.U.G.
SLOTTED STANDARDS · UNDERSIDE OF CONCRETE DECK ABOVE @ +17'-3" 572 NORTH BROADWAY
23 SEE ENGINEERING SURVEY (TBA) FOR ADDITIONAL ELECTRIC ROOM LAYOUT & INFO. · UNDERSIDE OF STEEL 'I'-BEAMS @ +15'-9"
· UNDERSIDE OF OPEN WEB JOISTS @ +15'-6" WHITE PLAINS, NEW YORK 10603
12 2'-0" W. X 6'-3" H. FLUSH ACCESS DOOR TO SHOW WINDOW (BOTT. @ +8" AFF) FE. RECESSED FIRE EXTINGUISHER CABINET
CAB.
13 3'-0" X 6'-10" H. FLUSH ACCESS DOOR TO SHOW WINDOW (W/ SURFACE MTD. TEL 914 289 0011
MIRROR ON DOOR) TOP OF BUILT-IN WHITE PLASTIC LAMINATE RECESSED WALL
W-1 DISPLAY CABINET TOP @ +9'-6" AFF
14 8" H. SHOW WINDOW PLATFORM AS BUILT
SITE SURVEY 06.21.22 TOP OF BUILT-IN WOOD OAK-LOOK PLASTIC LAMINATE
WO-2 RECESSED WALL DISPLAY CABINET @ +9'-6" AFF
FREE-STANDING BIRCH CABINET WITH SHELVING, HANGRODS
BC ANDFACE-OUTONSN
I GLESLOTTEDSTANDARDS@+2-0'1/2"OC
..
SITE SURVEY 05.19.22 TOP @ +9'-6" AFF.

H&M LEASE OUTLINE SQ. FT. PL-CAB. SMALL WHITE PLASTIC CABINET; TOP @ +6'-7", 1'-1" D.
( )

SALES AREA...........23,498 SQ. FT.± MM WHITE METAL MESH CABINET; +7'-9" H. X 4'-1" W. X 1'-8" D.
BOH AREA.................2,824 SQ. FT.± BLONDE WOOD PANELS FROM +11" AFF TO +7'-11" AFF WITH
O.A. LEASE AREA........26,322 SQ. FT.± BW
RECESSED SINGLE SLOTTED STDS. @ 2'-0 1/2" O.C.
FLUSH RECESSED SINGLE SLOTTED STANDARDS IN G.B. PERIMETER
FR WALLS FROM +8" TO 7'-8" AFF

3'-10" 8'-6" 13'-9" 2'-9" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 23'-6" 1'-6"

SALES AREA SALES AREA SALES AREA


LIC # AR0015561
3
EX200
15'-10" 1'-11" 1'-11" 22'-8" 2'-4" 16'-10 1/2" 5
9'-1 1
/ 2"
EX200 6

2'-4" 8"
"
20'-0 EX200

2'-4"
L END OF
Y PORTA PORTAL PLATFORM LIGHTBOX LIGHTBOX LIGHTBOX
R
ENT YP. BD . LIGHT BOX LIGHT BOX LIGHT BOX

2'-6"

2'-6"

2'-4"
22.63
-4" G ANT MTD.

1'-10
MEL. MEL. MEL. MEL. MEL. MEL. MEL. MEL. MEL. MEL.
MEL. MEL.
15'-8
+11'
MEL
2890 .
ND
2890 2890 2890 2890 2890 2890 2890 2890 2890 2890 2890
1/2"

3'-4 1/2"
@ PE N SIG 2890 MEL
. 7'-3" 6'-4"
H&M (3) WO-2 (5) WO-2 (2 2890
(4) WO-2
3 1/2 ) WO-2

"2'-8
22.48 2'-2 1/2" " 19'-0 1/2" 13'-7" 23'-3 1/2"
14'-6" 1'-9" 23'-1" 1'-10" 22'-11" 16'-8" 2"

'-1"
7'-6"

"
2'-0" 1/

13'-1 1/2"
(3) WO-2 (5) WO-2 (4) WO-2 (2) W

3'-1"1
9" 0
4'-1
15'-9"

O-2 1
22.3 " 2'-
7'-10

9'-6 1/2"
RECESSED
EXP. 2/28/2025
1/2"

22'-5 H&M SIGN


2'-0" " MEL

8"
. MALL

4'-3"
S E S E
(2)3'-0" X 7'-0"

1'-9" 2'-9"
2890 MEL LIGH
. T BO H.M. DOOR
22.2 MEL
X
(8) BW (10) BW
2'-2 1 (4) W
2890
2890
.

-10"
MEL
-10" /2" .
REVISION:

4'-5"
+10' O

7'-4"
+10' 14'-7 -2
2890

8'-9"
L@ M M M M
WAL 1/2"

1'-10"
2
2"

H:2000
IN

2890
A

MEL.
T
1/

22 CUR (4) W
EX200 . BD. O-2 9"
90

-4
.
EL

GYP
28

M
M

6'

37'-1 1/2"
8"

M
28 EL.
M
90

+9'-6" GYP. BD. PORTAL


1'-6"
-2
90
.
EL
28

O
M

2700
W
4)
) W 8"

(
-2
(4 4'-
90

15'-5"

15'-5"
.

2700
EL

O
28

24'-11 1/2"
1
M

21'-10"

2700
(5) FR
3'
25'-0"

-1
0 14

2700
1/ M '-1
2"
2"

1"
1/

2'-3"

2700
90
28

-3

52'-2" M
5'

1' ISSUE DATE:


-6

4'-3" 8"
"

S
90

8 1/2" 14'-7 1/2" 2'-2 1/2" 2'-2 1/2" 22'-10 1/2" 1'-4 1/2" 1'-4 1/2" 14'-7 1/2"

(1) WO-2
14'-8" 7" 15'-11" 7" 22'-2" 2'-10" 22'-11" 22'-7"
28

06.12.23 FOR REVIEW & APPROVALS

E
2"

MEL.
(4) WO-2 (4) WO-2 +9'-6" GYP. BD. PORTAL (5) WO-2 (6) WO-2 +9'-6" GYP. BD. PORTAL (4) WO-2
1/

(1) MM (1) MM (1) MM 07.17.23 FOR BIDS & PERMITS

2890
90

8"
14 (4) WO-2 (4) WO-2 (5) WO-2 (4) WO-2
-1 (6) WO-2
28

-3

'-1 M
4'

W
10"
90

M 2890 2890 2890 2890 2890 2890 2890 2890


)W "

) 1"
28

H:2430 H:2430 H:2430 2890 2890 2890 2890 2890 2890 2890 2890 2890 2890 2890 2890 2890 2890 2890
(5 '-9

(5

3'-0"

3'-0"
MEL. MEL. MEL. MEL. MEL. MEL. MEL. MEL.
-1

1'-10"
MEL. MEL. MEL. MEL. MEL. MEL. MEL. MEL. MEL. MEL. MEL. MEL. MEL. MEL. MEL.
18

M M

TYP.
21
90

(11) BW
28

SILVER SILVER SILVER


2890 2890 2890 2890 2890
(3) FR 2890
(3) FR (3) FR 2890
(3) FR (3) FR 2890
(3) FR (6) FR
2' (5) W-1 (4) BC (4) BC (4) BC 18'-2 1/2" 6'-10 1/2" 1'-10" 23'-4 1/2"
-1 23'-2" 1'-10"
0"
9" 22'-11" 1'-7" 26'-2" (6) FR TYP.
"
L

0
RTA

-1

1'-1

(6) FR
(5) W-1

22'-8 1/2"

76'-2"
14'-2"
2'

0"
O

4'-5
D. P

1 "
GY 3"
-
P. B

23'-3 1/2"

23'-3 1/2"

23'-3 1/2"
22'

EX200 56'-11 1/2"

67'-5"
LL

ARCH PROJECT NO.: 10835


25'-0"

WA
IGN D.
M S MT

2024
-4"

PRODUCT SEASON:

23'-2"
S
AIN

E
H& ANT

EGRESS CORRIDOR
1'

ND

SPACE NO.: 185


URT
+1

7"
PE

P. B 3"
D. C

JTA
-

DRAWN BY:

2700
22'

+9'-6" GYP. BD. PORTAL


SCALE: AS NOTED

2700
23'-2" 23'-4 1/2"
"

1'-10" 23'-2" 1'-10" 23'-2" 1'-10" 23'-2" 1'-10" 23'-2" 1'-10" 23'-2" 1'-10" 23'-2" 1'-10" 23'-2" 1'-10" 1'-10" 23'-2" 1'-10"
GY
2'-0

2700
0"

48'-6 1/2"
0'-1

19'-4"

2700
1'-10"

(8) FR
1'-10"

1'-10"
SHEET TITLE:
+1

20 M M M M M M M M M M

2700
3'-3
"
"
2'-0

2700
57'-1 1/2"
DIMENSION PLAN

2700
/2"
-7 1

2700
26'

19'-10"

S
E
(2) FR
25'-0"

23'-2"

2700

(4) BW
(4) BW

11'-4 1/2"
2700
14'-10"

THE MALL AT WELLINGTON GREEN


E
S

STORE NO. US 326 - RED MOD


3'-6 1/2" 20'-10 1/2"

BLVD.WELLINGTON, FL. 33414


2'-5 1/2" 23'-2 1/2" 22'-0 1/2"

(4) BC
4'-2 23'-7" 1'-5" 22'-11" 1'-5" 36'-4" 12'-5" 1'-10" 1'-10" 3'-8" 11'-3" 8" 5'-4" 22'-10" 4'-2"
" (5) W-1 (9) BW (6) FR (9) BW
(11) FR (6) W-1 X 7'-10"
1"

10300 W. FOREST HILL


2'-1

E S E S
1'-4"

GB. ENTRY (3) BC (3) BC


9" (5) W-1 (6) W-1 (1) MM (2) PL. CAB(1) MM

2890
PORTAL

4'-0" X 7'-0"

FILE

FILE
SAFE
(4) FR (6) FR 2890 2890
(3) FR
2890 2890 2890 2890 2890
(11) FR 2890 2890 2890 2890 2890 2890
H/C H/C
5'-10 1/2"1'-10"

1'-2"
2700 2700 2700 2700 H:2430 H:2430 H:2430 H:2430 2700 2700 2700 2700 2700 2700
2700 2700 2700 2700 2700 2700 2700 2700 2700 2700 2700
LAN

30"x60"
M

3'-8"
19 M RACK

(4) STAND., 3'-0" O.C.


(2) FR

MILLWORK

SECURITY
3'-0" X 7'-0"
DECO TABLE

MONITOR
7'-8"
7'-6"

30"x36"
SERVICE

2024
3'-0" X 7'-0"

3'-0" X 7'-0"

3'-0" X 7'-0"

3'-0" X 7'-0"
SINK

4'-4"
US US (2) BC (3) BC 3'-0" X 7'-0"

(5) FR LIGHTBOX
2890 2890
3'-8" X 7'-0"
J.85 K K.34 K.9 L M N O HI-LO
DRINKING 3'-6" X 7'-0"

23'-8" 9'-2" 17'-10" FOUNTAIN


8'-0" 3'-9"
(7) STAND., 3'-0" O.C. HALLWAY X 8'-0"
(8) STAND., 3'-0" O.C.

ENTRY TIME
CLOCK

13'-3"

3'-0" X 7'-0"
P
PERIMETER FIXTURE (DIMENSIONED) PLAN T-WAVE T-WAVE

LOCKERS
3'-8" X 7'-0"
VENDING

LOCKERS
SINK
LOCKER
SCALE: 1/8" = 1'-0" SALES AREA BACK TO BACK NIGHTBOX SUSP.
X-MER
SHELVING UNITS COUCH AREA
ELECTRIC ROOM
CONCRETE PAD
COAT
5'-0"

TRANS TRANS
HANGER FORMER FORMER

(5) STAND., 3'-0" O.C. (8) STAND., 3'-0" O.C. MONITOR 1125
KVA
1125
KVA
18 REFRIG. VENDING
MDP

SHEET NO:

H.M. DOOR W\
PANIC ALARM
3'-8" X 7'-0"
(2)3'-0" X 7'-0"
H.M. DOOR W\

EX-100B
PANIC ALARM

LOUNGE ADMIN OFFICE


MEN'S
TOILET ROOM
LAN ROOM
ELECTRIC ROOM
STOCK ROOM FITTING ROOM JANITORS ROOM
REV. NO:
WOMEN'S
TOILET ROOM
MANAGER/SECURITY
OFFICE

Q R S T U V
U.95 D.O.B. NO:
EXIST. PLAN KEY NOTES SYMBOL LEGEND
1 8" WIDE X 2" DEEP NEUTRAL PIER WITH BLACK CHANNEL REVEAL (TYP.) 15 LIGHTBOX (9'-2" WIDE), WITH PERFORATED METAL PANELS ON SIDES; TOP @ +2'-5", SYMBOL LEGEND SYMBOL LEGEND
RECESSED SINGLE SLOTTED STDS. @ 2'-0 1/2" O.C.
BOTT. @ +9'-7" AFF SYMBOL DESCRIPTION FLUSH RECESSED SINGLE SLOTTED STANDARDS IN G.B. PERIMETER
2 8" WIDE WHITE METAL SASH WITH 1/2" TK. GLASS (FULL HT. BUTT-JOINTS, (6" H. FR WALLS FROM +8" TO 7'-8" AFF
BASE, TOP @ +11'-4" AFF) 16 FLUSH RECESSED H&M ILLUMINATED SIGN -- DENOTES DRAWING NOTE ( SEE THIS DRAWING )
M LOCATION OF MIRROR - SEE TAG FOR DESCRIPTION.
3 POLISHED WHITE METAL CLADDING AT MALL SIDE OF R.U.G. (TYP.) 17 GYP. BD. SHOW WINDOW SOFFIT @ +11'-5" AFF DENOTES DEMISING PARTITION.
DENOTES INTERIOR PARTITIONS TO REMAIN ( SEE THIS DRAWING ) EXIT SIGNAGE
4 PAINTED FINISH AT SALES AREA SIDE OF R.U.G. (TYP.) 18 WHITE BREAK METAL FINISH RETURNS TO DBL. DOOR JAMBS

5 LINE OF R.U.G. LEASED AREA

6 2'-0" H. PENDANT MOUNTED H&M ILLUMINATED SIGN


19 LINE OF RECESSED LIGHT COVE (TYP.)
RECESSED
DISPLAY
RECESSED
DISPLAY
EXISTING CONDITIONS GENERAL NOTES & LIMITING FIELD CONDITIONS:
JEFFREY
20 MIRROR LOCATION (TYPICAL AS SHOWN). CABINET CABINET

7 GYP. BD. ENTRY PORTAL @ +11'-4" AFF


21 (3) REGISTER CASH-DESK WITH BACKWRAP
FREE-STANDING
DISPLAY
PANEL WITH
SLOTTED
STANDARDS
PERIMETER / FREE STANDING DISPLAY FIXTURES
· EXISTING 'LOOSE' SALES AREA FIXTURES ARE NOT SHOWN AND ARE TO BE VERIFIED TAYLOR
IN FIELD.
8 TOP OF STOREFRONT AND MALL SOFFIT @ + 13'-6" AFF
22 (1) ADA CASH-WRAP
·
·
ALL PERIMETER FIXTURE AND FITTING ROOM LAYOUTS ARE AS SHOWN.
8" WIDE, WHITE STOREFRONT GLAZING SASH WITH 1/2" BUTT JOINTED GLASS.
ARCHITECT
9 SENSORMATIC PEDESTAL (TYP.) NON-RECESSED FIXTURE
PERIMETER FRAMES 6" H. BRUSHED S.S. BASE WITH 2" RECESS, TOP OF STOREFRONT WINDOWS AND
DISPLAY CAB.
10 BOTTOM OF GYP. BD. CURTAIN WALL @ +10'-10" 22 SURFACE MOUNTED LIGHTBOX ABOVE BACKWRAP. MALL SOFFIT@ +11'-4" AFF
11 EMERGENCY RELEASE FRO R.U.G.
SLOTTED STANDARDS · UNDERSIDE OF CONCRETE DECK ABOVE @ +17'-3" 572 NORTH BROADWAY
23 SEE ENGINEERING SURVEY (TBA) FOR ADDITIONAL ELECTRIC ROOM LAYOUT & INFO. · UNDERSIDE OF STEEL 'I'-BEAMS @ +15'-9"
· UNDERSIDE OF OPEN WEB JOISTS @ +15'-6" WHITE PLAINS, NEW YORK 10603
12 2'-0" W. X 6'-3" H. FLUSH ACCESS DOOR TO SHOW WINDOW (BOTT. @ +8" AFF) FE. RECESSED FIRE EXTINGUISHER CABINET
CAB.
13 3'-0" X 6'-10" H. FLUSH ACCESS DOOR TO SHOW WINDOW (W/ SURFACE MTD. TEL 914 289 0011
MIRROR ON DOOR) TOP OF BUILT-IN WHITE PLASTIC LAMINATE RECESSED WALL
W-1 DISPLAY CABINET TOP @ +9'-6" AFF
14 8" H. SHOW WINDOW PLATFORM AS BUILT
SITE SURVEY 06.21.22 TOP OF BUILT-IN WOOD OAK-LOOK PLASTIC LAMINATE
WO-2 RECESSED WALL DISPLAY CABINET @ +9'-6" AFF
FREE-STANDING BIRCH CABINET WITH SHELVING, HANGRODS
BC ANDFACE-OUTONSN
I GLESLOTTEDSTANDARDS@+2-0'1/2"OC
..
SITE SURVEY 05.19.22 TOP @ +9'-6" AFF.

H&M LEASE OUTLINE SQ. FT. PL-CAB. SMALL WHITE PLASTIC CABINET; TOP @ +6'-7", 1'-1" D.
( )

SALES AREA...........23,498 SQ. FT.± MM WHITE METAL MESH CABINET; +7'-9" H. X 4'-1" W. X 1'-8" D.
BOH AREA.................2,824 SQ. FT.± BLONDE WOOD PANELS FROM +11" AFF TO +7'-11" AFF WITH
O.A. LEASE AREA........26,322 SQ. FT.± BW
RECESSED SINGLE SLOTTED STDS. @ 2'-0 1/2" O.C.
FLUSH RECESSED SINGLE SLOTTED STANDARDS IN G.B. PERIMETER
FR WALLS FROM +8" TO 7'-8" AFF

4
EX200
LIC # AR0015561
3'-10" 8'-6" 13'-9" 2'-9" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 23'-6" 1'-6"

SALES AREA SALES AREA SALES AREA


· GYP. BD. CLG. @+11'-5" AFF · GYP. BD. CLG. @+11'-5" AFF
3 · 1'-11 1/2" X 1'-11 1/2" LT. GRAY · 1'-11 1/2" X 1'-11 1/2" LT. GRAY
PORC. FLOOR TILES
EX200 15
PORC. FLOOR TILES
16 2 15 17 15 5
17 EX200 6
2 EX200
3 END OF
PLATFORM LIGHTBOX LIGHTBOX LIGHTBOX
LIGHT BOX LIGHT BOX LIGHT BOX
22.63 D. MEL. MEL. MEL. MEL. MEL. MEL. MEL. MEL. MEL. MEL. MEL.
T MT 14 MEL.
2890
MEL
.
DAN 2890 2890 2890 2890 2890 2890 2890 2890 2890 2890 2890
MEL
PEN M SIGN 2890 .
7 H& (3) WO-2 (5) WO-2 (4) WO-2 (2) W 2890
O-2 17 EXP. 2/28/2025
22.48 19
15
(TYP.)
4 (3) WO-2 16 2 18
15'-9"

22.3 10 REVISION:
RECESSED
9 MEL
.
H&M SIGN
MALL
6 2890 MEL
.
LIGH
T BO
S E S E
(2)3'-0" X 7'-0"
H.M. DOOR
22.2 5 2890 MEL
.
X
(8) BW (10) BW
(4) W 2890 MEL
.
17 O-2 2890
M M M M
2

H:2000
2890
MEL.
22
EX200
90
.
EL
28

M
M

M
M
28 EL.
M
90

+9'-6" GYP. BD. PORTAL


1'-6"
-2
90
.
EL
28

O
M

2700
12 )W
(4
0

15'-5"
9
.

2700
EL
28
M

2700
(5) FR
ISSUE DATE:
25'-0"

13

2700
M 06.12.23 FOR REVIEW & APPROVALS
14

2700
90

07.17.23 FOR BIDS & PERMITS


28

M
19

S
90

(TYP.)
28

E
MEL.
(1) MM (1) MM (1) MM 20

2890
90

-1 (4) WO-2 (4) WO-2 (5) WO-2 (6) WO-2 (4) WO-2
28

M
W (TYP.)
0

M
9

2890 2890 2890 2890 2890 2890 2890 2890


)
28

H:2430 H:2430 H:2430 2890 2890 2890 2890 2890 2890 2890 2890 2890 2890 2890 2890 2890 2890 2890

(5
MEL. MEL. MEL. MEL. MEL. MEL. MEL. MEL. MEL. MEL. MEL. MEL. MEL. MEL. MEL. MEL. MEL. MEL. MEL. MEL. MEL. MEL. MEL.
20 M M

TYP.
21 (TYP.)
90

(11) BW
19
28

SILVER SILVER SILVER


2890 2890 2890 2890 2890
(3) FR 2890
(3) FR (3) FR 2890
(3) FR (3) FR 2890
(3) FR (6) FR
5 (5) W-1 (4) BC (4) BC (4) BC
20
(6) FR TYP.
(TYP.)
19 20 ARCH PROJECT NO.: 10835

(6) FR
(TYP.) (TYP.) PRODUCT SEASON: 2024
1
11 SPACE NO.: 185
EX200
25'-0"

DRAWN BY: JTA


IGN D.
M S MT

S
SCALE:

E
AS NOTED
H& ANT

EGRESS CORRIDOR
ND
PE

2700
6
SHEET TITLE:

2700
8
7
TAGGED PERIMETER

2700
10
FIXTURE PLAN

2700
(8) FR
3 M M M M M M
20 M M M M
4

2700
2700
17
20

2700
(TYP.)

2700
2

THE MALL AT WELLINGTON GREEN


S
19

E
(2) FR
25'-0"

2700

STORE NO. US 326 - RED MOD

BLVD.WELLINGTON, FL. 33414


(4) BW
(TYP.)

(4) BW
2700
19

10300 W. FOREST HILL


(TYP.)
19

E
S
(4) BC
(TYP.)
(9) BW (6) FR (9) BW
X 7'-10" E S E S

23 21 22 21 22 23 GB. ENTRY (3) BC (3) BC


(5) W-1 (6) W-1 (1) MM (2) PL. CAB(1) MM

2890
PORTAL

4'-0" X 7'-0"

FILE

FILE
SAFE

2024
(4) FR (6) FR 2890 2890
(3) FR
2890 2890 2890 2890 2890
(11) FR 2890 2890 2890 2890 2890 2890
2700 2700 2700 2700 H:2430 H:2430 H:2430 H:2430 2700 2700 2700 2700 2700 2700
H/C H/C
2700 2700 2700 2700 2700 2700 2700 2700 2700 2700 2700
LAN

30"x60"
19 M M RACK

(4) STAND., 3'-0" O.C.


(2) FR

MILLWORK

3'-0" X 7'-0"

SECURITY
DECO TABLE

MONITOR
1

30"x36"
SERVICE

3'-0" X 7'-0"

3'-0" X 7'-0"

3'-0" X 7'-0"

3'-0" X 7'-0"
(2) BC (3) BC SINK 3'-0" X 7'-0"
US US
(5) FR LIGHTBOX
2890 2890
3'-8" X 7'-0"
J.85 K K.34 K.9 L M N O HI-LO
DRINKING 3'-6" X 7'-0"
FOUNTAIN

(7) STAND., 3'-0" O.C. HALLWAY X 8'-0"


· AC.T. CLG. @+9'-0" AFF
(8) STAND., 3'-0" O.C.

ENTRY TIME
CLOCK
· VCT FLR. TILES

3'-0" X 7'-0"
P
PERIMETER FIXTURE (TAGGED) PLAN T-WAVE T-WAVE

LOCKERS
3'-8" X 7'-0"
VENDING

LOCKERS
SINK
LOCKER
SCALE: 1/8" = 1'-0" SALES AREA BACK TO BACK NIGHTBOX SUSP.
X-MER
SHELVING UNITS COUCH AREA
· GYP. BD. CLG. @+11'-4" AFF
· 1'-11 1/2" X 1'-11 1/2" LT. GRAY
· AC.T. CLG. @+10'-1" AFF · AC.T. CLG. ELECTRIC ROOM SHEET NO:
· VCT FLR. TILES @+0
A
-9"'FFCOAT CONCRETE PAD
PORC. FLOOR TILES TRANS
23 TRANS

EX-100A
· VCT FLR.
HANGER FORMER FORMER
TILES
(5) STAND., 3'-0" O.C. (8) STAND., 3'-0" O.C. MONITOR 1125
KVA
1125
KVA
18 REFRIG. VENDING
MDP

H.M. DOOR W\
PANIC ALARM
3'-8" X 7'-0"
(2)3'-0" X 7'-0"
H.M. DOOR W\
PANIC ALARM

LOUNGE ADMIN OFFICE


· AC.T. CLG. @+9'-0" AFF · AC.T. CLG. @+9'-0" AFF
MEN'S · VCT FLR. TILES · VCT FLR. TILES REV. NO:
TOILET ROOM
· GYP. BD. CLG. @+9'-0" AFF LAN ROOM
· 1'-11 1/2" X 1'-11 1/2" LT. GRAY ELECTRIC ROOM
STOCK ROOM FITTING ROOM JANITORS ROOM · AC.T. CLG. @+9'-0" AFF
PORC. FLOOR TILES · NO CEILING
· AC.T. CLG. @+9'-8" AFF · GYP. BD. CLG. @+10'-0" AFF · VCT FLR. TILES
· AC.T. CLG. @+9'-0" AFF · 3'-0"H.WHITE C.T. WAINSCOTING · VCT FLR. TILES
· VCT FLR. TILES · PORC. FLOOR TILES
· 13" X 13" LT. PORC. FLOOR TILES WOMEN'S
· 3'-0"H.WHITE C.T. WAINSCOTING
TOILET ROOM
MANAGER/SECURITY
· GYP. BD. CLG. @+9'-0" AFF
· 1'-11 1/2" X 1'-11 1/2" LT. GRAY OFFICE D.O.B. NO:
PORC. FLOOR TILES · AC.T. CLG. @+9'-0" AFF
· 3'-0"H.WHITE C.T. WAINSCOTING · VCT FLR. TILES
Q R S T U V
U.95
EXIST. PLAN KEY NOTES
1 8" WIDE X 2" DEEP NEUTRAL PIER WITH BLACK CHANNEL REVEAL (TYP.)

6 3 5 3 2 2 STOREFRONT; 8" WIDE X 2" HIGH WHITE METAL FRAMING WITH 1/2" TK. GLASS
(FULL HT. BUTT-JOINTS, (6" H. BRUSHED S.S. BASE, TOP @ +11'-4" AFF)

3 POLISHED WHITE BREAK METAL CLADDING AT MALL SIDE OF STOREFRONT (TYP.)

4 LINE OF R.U.G.
JEFFREY

2" 2'-2"
5 2'-0" H. PENDANT MOUNTED H&M ILLUMINATED SIGN

TOP OF STOREFRONT AND MALL SOFFIT


TAYLOR

2'-0"
6 LINE OF ROLL - UP GRILLE

7 FLUSH-RECESSED 'H&M' ILLUMINATED SIGN ARCHITECT


6 8 6" H. BRUSHED STAINLESS STEEL BASE

13'-6"
572 NORTH BROADWAY

10'-6"
11'-4"

13'-6"
1 WHITE PLAINS, NEW YORK 10603

TEL 914 289 0011

6" 2"
AS BUILT
SITE SURVEY 06.21.22
3 22'-2 1/2" 3 2

SITE SURVEY 05.19.22

STOREFRONT ELEVATION 1 H&M LEASE OUTLINE SQ. FT.


( )
SCALE: 1/4" = 1'-0"
SALES AREA...........23,498 SQ. FT.±
BOH AREA.................2,824 SQ. FT.±
O.A. LEASE AREA........26,322 SQ. FT.±

3 2
LIC # AR0015561

2" 2'-2"

TOP OF STOREFRONT AND MALL SOFFIT


13'-6"
10'-6"

EXP. 2/28/2025

REVISION:
6" 2"

2
STOREFRONT ELEVATION 2
SCALE: 1/4" = 1'-0"

ISSUE DATE:
06.12.23 FOR REVIEW & APPROVALS
07.17.23 FOR BIDS & PERMITS

2 3 6 5 2 3 2 3
2'-2"

2'-2"

2'-2"
ARCH PROJECT NO.: 10835
TOP OF STOREFRONT AND MALL SOFFIT

TOP OF STOREFRONT AND MALL SOFFIT


2"

2"

2"
PRODUCT SEASON: 2024
2'-0"

SPACE NO.: 185


DRAWN BY: JTA
SCALE: AS NOTED
13'-6"

13'-6"
10'-6"

10'-6"

10'-6"
11'-4"

13'-6"

SHEET TITLE:
EXISTING
STOREFRONT
ELEVATIONS
6" 2"

6" 2"

6" 2"
2 3 3 2 2

THE MALL AT WELLINGTON GREEN


STORE NO. US 326 - RED MOD

BLVD.WELLINGTON, FL. 33414


STOREFRONT ELEVATION 3 STOREFRONT ELEVATION 4

10300 W. FOREST HILL


SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0"

2024
2 3 3 2 16 3
2'-2"

2'-2"

2'-2"
TOP OF STOREFRONT AND MALL SOFFIT

TOP OF STOREFRONT AND MALL SOFFIT


2"

2"

2"
SHEET NO:
13'-6"

13'-6"
10'-6"

10'-6"

10'-6"
D D
EX-200
REV. NO:
6" 2"

6" 2"

6" 2"
ENTRY TO MALL
EGRESS CORRIDOR
2 BEYOND (NIC) 8 3 2 8 7

STOREFRONT ELEVATION 5 STOREFRONT ELEVATION 6 D.O.B. NO:


SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0"
REFER TO DRAWING D-211 FOR NOTE:
ADDITIONAL NOTES AND INFO. ALL DEMOLITION & REMOVAL BY G.C., U.O.N.
SYMBOL LEGEND
SYMBOL DESCRIPTION
EXISTING PARTITION TO REMAIN. G.C. TO
DEMO NOTE: PATCH/REPAIR ANY EXISTING OR NEW DAMAGE
INCURRED FROM NEW CONSTRUCTION & CLEAN,
G.C. TO USE 6" WIDE BLUE PAINTERS TAPE TO TAPE ALL WALLS THAT
ARE TO REMAIN AND NOT BE REMOVED OR MODIFIED
PAINT, ETC. TO BRING TO LIKE-NEW CONDITION. ALL
TOUCH-UP FINISHES TO MATCH ADJACENT FINISHES. JEFFREY
EXISTING NON LOAD BEARING PARTITION/DOOR TO
BE REMOVED
TAYLOR
EXISTING FIXTURE, MILLWORK, AND/OR FURNITURE,
ARCHITECT
TO BE REMOVED U.O.N. REFER TO CONSTRUCTION
PLAN FOR ADDITIONAL INFORMATION.
572 NORTH BROADWAY
X CONSTRUCTION TAG NOTE (SEE DWG.) WHITE PLAINS, NEW YORK 10603
3'-10" 8'-6" 13'-9" 2'-9" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0"

TEL 914 289 0011


EXISTING NEW OPEN EXISTING
EXSTG. MENS
KEY NOTES
EXISTING NEW MENS MEN'S EXISTG. MENS LIGHTBOX LIGHTBOX OPEN WINDOW NEW MENS
MEN'S ENTRY OPEN WINDOW SALES AREA OPEN WINDOW WINDOW (WOMENS) WINDOW (KIDS)
113
OPEN WINDOW # DESCRIPTION
108 109 101 110 111 112 114
1 EXISTING PERIMETER FIXTURES TO REMAIN - SEE FINISH PLAN FOR
WARDROBE FIXTURE RE-FINISHING REQUIREMENTS.

1A EXISTING WALL MOUNTED MIRROR TO REMAIN - IF MIRROR IS


DAMAGED, REPLACE TO MATCH EXISTING. COORDINATE WITH H&M PM
5 4 10 10 10
EXISTING FLOORING AND BASE TO REMAIN U.O.N. PATCH AND REPAIR TO
1B MATCH EXISTING WHERE REQUIRED AT AREAS OF NEW CONSTRUCTION
AND REMOVALS

LIGHT BOX LIGHT BOX LIGHT BOX


1C EXISTING CEILING, LIGHT COVE AND SOFFITS TO REMAIN 'AS-IS' U.O.N.
PATCH AND REPAIR TO MATCH AND ALIGN WITH EXISTING WHERE
22.63 REQUIRED AT AREAS OF NEW CONSTRUCTION.

MATCHLINE

MATCHLINE
AREA 'B'

AREA 'A'
L
EXISTING DEMISING WALL AND ALL RELATED CONSTRUCTION TO
22.48 NEW MENS
OPEN WINDOW REMAIN. G.C. TO PATCH AND REPAIR ANY DAMAGE DONE DURING AND
9 8 8 1 10A 1D AFTER DEMOLITION, BRING TO LIKE "NEW CONDITION" AND ENSURE
107
FIRE RATING IS MAINTAINED THROUGHOUT, AS REQUIRED.
15'-9"

(TYP.) TYP.
22.3 5
EXISTING MEP AND ALL RELATED COMPONENTS TO REMAIN (U.O.N.) .
LIGH
1C T BO
RELOCATE RELATED MEP EQUIPMENT AS REQD. AND SHOWN ON MEP
X
LIC # AR0015561
22.2 1E DRAWINGS. G.C. TO COORDINATE WITH ELECTRICAL DRAWINGS,
4 DEMOLITION & REMOVAL GENERAL AND KEY NOTES FOR MORE
M M M INFORMATION.
22 8 1 EXISTING LIGHTING AND ALL RELATED COMPONENTS TO REMAIN (U.O.N.)
4 1F
M ALL COVE LIGHTING TO BE TURNED OFF AND / OR DISCONNECTED AT
EXISTING (TYP.) M
DISPLAY WINDOW PANEL. G.C. TO COORDINATE WITH ELECTRICAL DRAWINGS.
1J
106 8
1G EXISTING DROPPED G.B. SOFFIT TO REMAIN AT STOREFRONT.
1J
EXISTING CEILING PERIMETER COVE (GAP) TO REMAIN THROUGHOUT
1H
SALES AREAS
7
25'-0"

1J EXISTING PODIUM TO REMAIN - PATCH AND REPAIR TO [LIKE-NEW'


M CONDITION
NEW WOMENS 1C
OPEN WINDOW EXISTING CASHWRAP, BACKWRAP, POSTERS AND ALL RELATED EXP. 2/28/2025
105 M
2 EQUIPMENT TO BE REMOVED. ELECTRICAL CONDUITS TO BE REUSED,
IF POSSIBLE, FOR USE WITH NEW CASHWRAP. PATCH FLOOR AS
1 8 1 1C 1 1 1C 1 REQD. TO MATCH EXISTING FLOOR FINISH. REVISION:
3
4 TYP. M 3 EXISTING LIGHT TO BE REMOVED AND WIRING CAPPED, AS REQD.
M PATCH CEILING AS REQD.
4 6
21 M M M M
4 PORTION OF EXISTING WALL TO BE REMOVED,(COORDINATE REMOVAL
WITH CONSTRUCTION & FIXTURE PLANS), PATCH AND REPAIR
8
ADJACENT WALL, FLOOR AND CEILING, AS REQD., TO MATCH AND ALIGN
WITH EXISTING.
1 1 1A 1 1C 1 1A 1
EXISTING EXISTING R.U.G. KEY SWITCH TO BE CAREFULLY REMOVED AND
WOMENS ENTRY TYP. TYP. 4A
RELOCATED TO NEW WALL LOCATION, AS REQD.
104 4A 3
EXISTING PODIUM TO BE REMOVED, AS REQD. PATCH AND REPAIR ANY
5 DAMAGED FLOORING AND BASE FROM BELOW PODIUM, TO MATCH AND
25'-0"

ALIGN WITH EXISTNG.


1 1A 1B 1C 1H 2 3 4 6 8
6 EXISTING MIRROR TO BE REMOVED, PATCH AND REPAIR TO MATCH ISSUE DATE:
1C ADJACENT WALL, AS REQD.
06.12.23 FOR REVIEW & APPROVALS
EXISTING DOOR TO BE REMOVED, PATCH AND REPAIR TO MATCH
7 07.17.23 FOR BIDS & PERMITS
ADJACENT WALL, AS REQD.
3 EXISTING WARDROBE FIXTURES TO BE REMOVED. PATCH AND REPAIR
8
WALL & FLOOR, AS REQD., TO MATCH AND ALIGN WITH EXISTING.
6
EXISTING DROPPED SOFFIT TO BE REMOVED. PATCH AND REPAIR
(TYP.) 9 G.B. CEIING, AS REQD., TO MATCH AND ALIGN WITH EXISTING.
20 M M M M M
M
M M

10 EXISTING FREE - STANDING LIGHTBOX TO BE REMOVED.


±
-0"

EXSTG. WOMENS EXISTING WALL MOUNTED LIGHTBOX, WIRING AND RELATED


1A 10A
48'

OPEN WINDOW HARDWARE TO BE REMOVED AS REQD.


1G

103 TYP.

5 5 11 EXISTING HANGING FIXTURES TO BE CAREFULLY REMOVED AND ARCH PROJECT NO.: 10835
SAVED FOR RELOCATION.
PRODUCT SEASON: 2024
25'-0"

12 EXISTING FITTING ROOM MIRRORS AND INTERIOR PACKAGE SPACE NO.: 185

PLASTIC
FIXTURES TO BE REMOVED (CURTAIN AND ROD TO REMAIN). SEE
CONSTRUCTION AND ENLARGED FITTING ROOM PLANS FOR INFO. DRAWN BY: JTA

PAPER
REGARDING NEW INTERIOR PACKAGING INSTALLATION SCALE: AS NOTED

TRASH
8 EXISTING FITTING ROOM LIGHTING TO REMAIN 'AS-IS' U.O.N. TO BE
3'-10" 13
1 1A 1 1C 1 1 8 1 3 6 3 2 3 6 CHECKED FOR PROPER OPERATION.
TYP. (TYP.) 4 SHEET TITLE:
3 EXISTING FITTING ROOM FLOORING TO REMAIN 'AS-IS' U.O.N. CLEAN
14

4'-0" X 7'-0"
& POLISH AS REQD.
8
H/C H/C
EXISTING FITTING ROOM CUBICLES TO REMAIN 'AS-IS' - PATCH
REMOVAL FLOOR PLAN
19 15
3 REPAIR AND CLEAN AS REQUIRED. AREA 'A'

SERVICE
EXISTING 1C EXISTING VENDING MACHINE TO BE REMOVED. STORE TEAM TO

SINK
WOMENS 3 HW
3'-0" X 7'-0"
16
SALES AREA COORDINATE REMOVAL.
(TYP.)
100 3'-4" X 7'-0" 3'-8" X 7'-0"
EXISTING BOH FLOORING TO BE REMOVED AND FLOOR PREPED FOR
J.85 K K.34 K.9 L M N O 4 17
INSTALLATION OF NEW FLOOR FINISH AND BASE TO MATCH
EXISTING.
8 8 17
7 18 ALL EXISTING, FIXTURES, FURNITURE, EQUIPMENT, ETC. TO REMAIN
'AS-IS' UNLESS OTHERWISE NOTED

THE MALL AT WELLINGTON GREEN


2'-6"

P 12 13 14 15

SAMPLE WALL

STORE NO. US 326 - RED MOD

BLVD.WELLINGTON, FL. 33414


MANNEQUIN /
NEW CLICK & PROP STORAGE 19 EXISTING WALL MOUNTED EQUIPMENT TO BE RELOCATED. VERIFY &
COLLECT STOCK CONFIRM EQUIPMENT RELOCATION IN FIELD WITH H&M PROJ. MGR. &
127 11 TEAM

10300 W. FOREST HILL


FACILITIES
NOTES:
VISUAL
CHECK-IN ALL EXISTING PARTITIONS TO BE PATCH AND REPAIRED AS REQUIRED

2024
18 AFTER REMOVAL WORK FOR NEW LIKE CONDITION.

ALL DOORS ARE EXISTING UNLESS OTHER WISE NOTED.


EXISTING NEW
EXISTING FITTING EXISTING EXISTING PROCESSING

MATCHLINE

MATCHLINE
STOCK RM. ROOM STOCK RM. JAN. CL. AREA

AREA 'B'

AREA 'A'
126 127 126 125
17 17 17 18

EXTERIOR

Q R S
SHEET NO:

REMOVAL FLOOR PLAN @ AREA 'A'


SCALE: 1/8" = 1'-0"
1
D-110
REV. NO:

D.O.B. NO:
REMOVAL GENERAL NOTES NOTE:
ALL DEMOLITION & REMOVAL BY G.C., U.O.N.
THE WORK SHALL INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING:

1. PERFORM ALL DEMOLITION IN ACCORDANCE WITH THE CONTRACT


DOCUMENTS, INCLUDING BUT NOT LIMITED TO:
SYMBOL LEGEND
1.1. N/A
REMOVAL OF MECHANICAL AND ELECTRICAL AS REQUIRED,
SYMBOL DESCRIPTION
INCLUDING BUT NOT LIMITED TO: DIFFUSERS, LIGHTING (MAINTAIN
TEMPORARY EMERGENCY LIGHTING), CONDUIT/ PIPING, CABLING, EXISTING PARTITION TO REMAIN. G.C. TO
DEMO NOTE: HARDWARE, DATA/ COM WIRING AS REQUIRED SEE MECH. & ELEC.
DRAWINGS. ANY EXIST. ABANDONED DUCTWORK, ELECTRICAL HVAC
PATCH/REPAIR ANY EXISTING OR NEW DAMAGE
INCURRED FROM NEW CONSTRUCTION & CLEAN,
EQUIPMENT, ETC. MUST BE REMOVED BY G.C. AS PART OF
G.C. TO USE 6" WIDE BLUE PAINTERS TAPE TO TAPE ALL WALLS THAT
ARE TO REMAIN AND NOT BE REMOVED OR MODIFIED
DEMOLITION SCOPE OF WORK.

DO NOT REMOVE LIVE SERVICES SERVING ADJACENT AREAS. REFER TO


PAINT, ETC. TO BRING TO LIKE-NEW CONDITION. ALL
TOUCH-UP FINISHES TO MATCH ADJACENT FINISHES. JEFFREY
MECH./ ELEC. DRAWINGS FOR MORE INFORMATION.

1.2. REMOVAL
N/A OF WALL, & CEILINGS FINISHES AS SHOWN
EXISTING NON LOAD BEARING PARTITION/DOOR TO
BE REMOVED
TAYLOR
1.3. FLOORING AND ASSOCIATED UNDERLAYMENT TO BE REMOVED
N/A
WHERE NOTED ON DRAWINGS.
EXISTING FIXTURE, MILLWORK, AND/OR FURNITURE,
ARCHITECT
1.4. N/A
REMOVAL OF COLUMN CLADDING TO FIREPROOFING ONLY WHERE TO BE REMOVED U.O.N. REFER TO CONSTRUCTION
INDICATED ON DEMO PLANS. USE CAUTION WHEN REMOVING COLUMN PLAN FOR ADDITIONAL INFORMATION.
CLADDING SO AS NOT TO DISTURB EXISTING STRUCTURAL ELEMENTS
OR FIREPROOFING. 572 NORTH BROADWAY
1.5. REMOVAL OF ALL MISCELLANEOUS ITEMS (PANELS, ACCESSORIES, X CONSTRUCTION TAG NOTE (SEE DWG.) WHITE PLAINS, NEW YORK 10603
EQUIPMENT) AS REQUIRED THROUGHOUT.

2. PROVIDE PROTECTION FOR ADJACENT SPACES/ PROPERTIES AND ALL


EXISTING WORK TO REMAIN. ANY DAMAGE TO EXISTING WORK INTENDED
TO REMAIN SHALL BE REPAIRED BY THE CONTRACTOR AT HIS EXPENSE.
TEL 914 289 0011
3. ALL PIPING AND WIRING TO BE REMOVED SHALL BE REMOVED TO MAIN
KEY NOTES
SERVICE ON FLOOR AND SHALL BE PROPERLY CAPPED AND PLUGGED.
# DESCRIPTION
4. CONTRACTOR IS RESPONSIBLE FOR REMOVALS AND CAPPING OR
REROUTING OF ANY MATERIALS DISCOVERED WITHIN SPACE DURING EXISTING PERIMETER FIXTURES TO REMAIN - SEE FINISH PLAN FOR
NEW MENS EXISTG. KIDS EXISTG. KID'S DEMO. 1
OPEN WINDOW SALES AREA OPEN WINDOW WARDROBE FIXTURE RE-FINISHING REQUIREMENTS.
114 102 116 5. EXISTING WORK NOT SPECIFICALLY SHOWN TO BE DEMOLISHED, THAT
IMPEDES INSTALLATION OF THE WORK, IS TO BE DEMOLISHED UPON THE
1A EXISTING WALL MOUNTED MIRROR TO REMAIN - IF MIRROR IS
WRITTEN APPROVAL OF THE ARCHITECT. DAMAGED, REPLACE TO MATCH EXISTING. COORDINATE WITH H&M PM
6. ALL FIRE ALARM DEVICES (U.O.N.) TO REMAIN 'AS-IS'.
EXISTING FLOORING AND BASE TO REMAIN U.O.N. PATCH AND REPAIR TO
7. SCARIFY OR GRIND FLOORS AND FILL CRACKS AS NECESSARY TO 1B MATCH EXISTING WHERE REQUIRED AT AREAS OF NEW CONSTRUCTION
N/A SMOOTH, CLEAN SURFACE FOR NEW FLOORING (TYP.)
PROVIDE AND REMOVALS

1C EXISTING CEILING, LIGHT COVE AND SOFFITS TO REMAIN 'AS-IS' U.O.N.


PATCH AND REPAIR TO MATCH AND ALIGN WITH EXISTING WHERE
REQUIRED AT AREAS OF NEW CONSTRUCTION.
DEMOLITION GENERAL NOTES
EXISTING DEMISING WALL AND ALL RELATED CONSTRUCTION TO
A. G.C. TO COORDINATE ALL PHASES OF DEMOLITION FOR PROJECT AND REMAIN. G.C. TO PATCH AND REPAIR ANY DAMAGE DONE DURING AND

MATCHLINE

MATCHLINE
NOTIFY ARCHITECT OF ANY DISCREPANCIES OR CONFLICTING 1D

AREA 'B'

AREA 'A'
AFTER DEMOLITION, BRING TO LIKE "NEW CONDITION" AND ENSURE
CONDITIONS WHICH WOULD INTERFERE WITH THE SATISFACTORY
COMPLETION OF THE WORK, PRIOR TO THE START OF DEMOLITION. FIRE RATING IS MAINTAINED THROUGHOUT, AS REQUIRED.

10A B. PROTECT AND SEAL ALL DIFFUSERS DURING DEMOLITION AND EXISTING MEP AND ALL RELATED COMPONENTS TO REMAIN (U.O.N.) .
CONSTRUCTION. RELOCATE RELATED MEP EQUIPMENT AS REQD. AND SHOWN ON MEP LIC # AR0015561
C. G.C. TO COORDINATE WITH BUILDING MANAGEMENT AND TO CONFORM 1E DRAWINGS. G.C. TO COORDINATE WITH ELECTRICAL DRAWINGS,
TO ALL BUILDING REGULATIONS WITH REGARD TO DEMOLITION. DEMOLITION & REMOVAL GENERAL AND KEY NOTES FOR MORE
LIGH MALL
T BO
X (2)3'-0" X 7'-0" INFORMATION.
H.M. DOOR D. G.C. TO MAINTAIN THE INTEGRITY OF EXISTING DEMISING PARTITIONS.
22.8 EXISTING LIGHTING AND ALL RELATED COMPONENTS TO REMAIN (U.O.N.)
4 E. G.C. PATCH AND/OR REPAIR FLOOR, CEILING, AND/OR WALL SURFACES 1F
ALL COVE LIGHTING TO BE TURNED OFF AND / OR DISCONNECTED AT
22.1 WHERE REMOVALS ARE MADE AND PREPARE TO RECEIVE NEW FINISHES.
PANEL. G.C. TO COORDINATE WITH ELECTRICAL DRAWINGS.
F. ALL REMOVAL AND DEMOLITION DEBRIS SHALL BE REMOVED AT LEAST
8 1 1 1 ONCE PER DAY, OR AS REQUIRED TO MAINTAIN SAFE WORKING
(TYP.) M
CONDITIONS. VERIFY METHODS AND LOCATION OF REMOVAL WITH 1G EXISTING DROPPED G.B. SOFFIT TO REMAIN AT STOREFRONT.
LANDLORD.

G. G.C. SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND PAY ALL EXISTING CEILING PERIMETER COVE (GAP) TO REMAIN THROUGHOUT
1H
FEES AS PART OF THE SCOPE OF WORK FOR THIS PROJECT. G.C. MUST SALES AREAS
PLAN, SCHEDULE, AND COORDINATE ALL REMOVALS(AND NEW WORK) TO
AVOID INTERRUPTION OF SERVICES (ELECTRICAL, HVAC, FIRE EXISTING PODIUM TO REMAIN - PATCH AND REPAIR TO [LIKE-NEW'
PROTECTION) 1J
CONDITION
H. IT IS THE RESPONSIBILITY OF THE G.C. TO FIELD VERIFY ALL CONDITIONS EXP. 2/28/2025
AND DIMENSIONS WITHIN THE SCOPE OF WORK FOR THIS PROJECT. G.C. EXISTING CASHWRAP, BACKWRAP, POSTERS AND ALL RELATED
SHALL REPORT ANY PROBLEMS AND/OR DISCREPANCIES TO ARCHITECT 2 EQUIPMENT TO BE REMOVED. ELECTRICAL CONDUITS TO BE REUSED,
AND TENANT PRIOR TO START OF DEMOLITION WORK. IF POSSIBLE, FOR USE WITH NEW CASHWRAP. PATCH FLOOR AS
I. PRIOR TO THE START OF DEMOLITION THE G.C. WILL VISIT AND EXAMINE REQD. TO MATCH EXISTING FLOOR FINISH. REVISION:
M
THE SITE CONDITIONS AND NOTIFY ARCHITECT OF ANY AND ALL
DISCREPANCIES THAT MAY AFFECT TENANT'S CONSTRUCTION DETAILS
AT THE START AND COMPLETION OF THE NEW G.C. SCOPE OF WORK. 3 EXISTING LIGHT TO BE REMOVED AND WIRING CAPPED, AS REQD.
1
PATCH CEILING AS REQD.
J. THE G.C. WILL PROTECT AND MAINTAIN EXISTING FIRE PROTECTION
1A SPRINKLER SYSTEM DURING THE DEMOLITION OF THE TENANT'S LEASED
4 PORTION OF EXISTING WALL TO BE REMOVED,(COORDINATE REMOVAL
1A 6 TYP. SPACE. THE G.C. FIRE PROTECTION CONTRACTOR WILL SURVEY THE
EXISTING SYSTEM AND DOCUMENT REQUIRED REVISIONS FOR PROPER WITH CONSTRUCTION & FIXTURE PLANS), PATCH AND REPAIR
TYP. COVERAGE IN THE NEW RETAIL LAYOUT. PRIOR TO FABRICATION AND ADJACENT WALL, FLOOR AND CEILING, AS REQD., TO MATCH AND ALIGN
M M M
INSTALLATION OF THE MODIFIED SYSTEM. THE CONTRACTOR WILL WITH EXISTING.
M M
SUBMIT SHOP DRAWINGS TO THE LANDLORD. ARCHITECT AND CITY FOR
APPROVAL. EXISTING R.U.G. KEY SWITCH TO BE CAREFULLY REMOVED AND
4A
1 1 K. DURING DEMOLITION, PROVIDE AND PLACE BRACING AND/OR SHORING RELOCATED TO NEW WALL LOCATION, AS REQD.
1 AS REQUIRED TO PREVENT MOVEMENT OF STRUCTURE. THE G.C. IS TO
ASSUME LIABILITY FOR ANY MOVEMENT. DAMAGE OR INJURY DUE TO EXISTING PODIUM TO BE REMOVED, AS REQD. PATCH AND REPAIR ANY
LACK OF SAFETY PLANNING. MAKE SAFE THE SITUATION PRIOR TO 5 DAMAGED FLOORING AND BASE FROM BELOW PODIUM, TO MATCH AND
PROCEEDING WITH DEMOLITION.
ALIGN WITH EXISTNG.
L. PRIOR TO DEMOLITION THE G.C. IS TO EVALUATE THE DISPOSITION OF
ALL EXISTING FUNCTIONS UTILITIES. STANDARD CONSTRUCTION SAFETY 6 EXISTING MIRROR TO BE REMOVED, PATCH AND REPAIR TO MATCH ISSUE DATE:
PRACTICES AND SAFETY MEASURES ARE TO BE EXERCISED AND ADJACENT WALL, AS REQD.
ENFORCED IN THE DISCONNECTION OF THESE UTILITIES. REMOVE AND 06.12.23 FOR REVIEW & APPROVALS
CAP AS REQUIRED. DO NOT JUST ABANDON. EXISTING DOOR TO BE REMOVED, PATCH AND REPAIR TO MATCH

EGRESS CORRIDOR
1B 1C 1D 1E 1F 6 7 07.17.23 FOR BIDS & PERMITS
ADJACENT WALL, AS REQD.
M. THE G.C. IS TO MINIMIZE DAMAGE TO DEMISING WALLS DURING
DEMOLITION. THE G.C. SHALL PATCH AND REPAIR ANY DAMAGE AS EXISTING WARDROBE FIXTURES TO BE REMOVED. PATCH AND REPAIR
REQUIRED. 8
WALL & FLOOR, AS REQD., TO MATCH AND ALIGN WITH EXISTING.
N. THE G.C. IS TO PROVIDE AND MAINTAIN TEMPORARY LIGHTING & POWER EXISTING DROPPED SOFFIT TO BE REMOVED. PATCH AND REPAIR
THROUGHOUT THE CONSTRUCTION PROCESS FOR THE SAFETY AND 9 G.B. CEIING, AS REQD., TO MATCH AND ALIGN WITH EXISTING.
OPERATION OF CONSTRUCTION EQUIPMENT AND WORKERS.
6 6
O. THE HVAC CONTRACTOR TO INSPECT EXISTING CONDITIONS PRIOR EXISTING FREE - STANDING LIGHTBOX TO BE REMOVED.
(TYP.) (TYP.) DEMOLITION AND DETERMINE WHETHER ANY COMPRESSOR
10
M M M REFRIGERANT LINES ARE PRESENT THAT MUST BE PROPERLY DRAINED
M (TO E.P.A. STANDARD) PRIOR TO DEMOLITION. EXISTING WALL MOUNTED LIGHTBOX, WIRING AND RELATED
10A HARDWARE TO BE REMOVED AS REQD.
P. G.C. TO REMOVE ALL DEMOLISHED MATERIALS OFF SITE IMMEDIATELY.

Q. G.C. TO PERFORM DEMOLITION IN ACCORDANCE WITH GOVERNING 11 EXISTING HANGING FIXTURES TO BE CAREFULLY REMOVED AND ARCH PROJECT NO.: 10835
AUTHORITIES. SAVED FOR RELOCATION.
PRODUCT SEASON: 2024
R. ALL DEMOLITION PERFORMED IN EXCESS OF THAT REQUIRED IS TO BE
REPAIRED WITHOUT COST TO THE OWNER. 12 EXISTING FITTING ROOM MIRRORS AND INTERIOR PACKAGE SPACE NO.: 185
FIXTURES TO BE REMOVED (CURTAIN AND ROD TO REMAIN). SEE
S. G.C. TO PHASE DEMOLITION AS TO EXCESSIVE NOISE, VIBRATION AND/OR
CONSTRUCTION AND ENLARGED FITTING ROOM PLANS FOR INFO. DRAWN BY: JTA
FUMES SO AS NOT TO DISRUPT ADJACENT TENANTS. ANY DEMOLITION
DEEMED EXCESSIVE BY THE LANDLORD IS TO TAKE PLACE AFTER MAIN REGARDING NEW INTERIOR PACKAGING INSTALLATION SCALE: AS NOTED
WORKING HOURS OR AS ARRANGED BY BUILDING MANAGEMENT.
PLASTIC

1 1 1 EXISTING FITTING ROOM LIGHTING TO REMAIN 'AS-IS' U.O.N. TO BE


T. ANY BARRICADES INDICATED ARE TO BE CONSTRUCTED AND REMOVED 13
PAPER

BY THE G.C. CHECKED FOR PROPER OPERATION.


SHEET TITLE:
TRASH

8 U. G.C. TO PATCH AND REPAIR ANY DAMAGE TO EXISTING FIRE PROOFING EXISTING FITTING ROOM FLOORING TO REMAIN 'AS-IS' U.O.N. CLEAN
14
3'-10" ON WALLS, COLUMNS, FLOORS, BEAMS, JOISTS, ETC. & POLISH AS REQD.
MGR./SECR.
OFFICE V. G.C. TO ENSURE THAT THE TENANTS SPACE IS STRUCTURALLY SOUND EXISTING FITTING ROOM CUBICLES TO REMAIN 'AS-IS' - PATCH
REMOVAL FLOOR PLAN
3 15
117 AND WATERTIGHT. REPAIR AND CLEAN AS REQUIRED. AREA 'B'
4'-0" X 7'-0"

17 W. G.C. TO BROOM CLEAN TENANT'S LEASED SPACE.


16 EXISTING VENDING MACHINE TO BE REMOVED. STORE TEAM TO
X. THE REMOVAL OF ANY EXISTING MATERIALS, EQUIPMENT, PIPING, DUCTS COORDINATE REMOVAL.
AND WIRING WILL BE THE RESPONSIBILITY OF THE G.C. ALL EXISTING
3'-0" X 7'-0"

EXISTING BOH FLOORING TO BE REMOVED AND FLOOR PREPED FOR


SERVICE

MATERIALS, EQUIPMENT, PIPING, DUCTS AND WIRING CREATED BY THE 17


SINK

HW DEMOLITION OF THE CONCRETE FLOORING AND WALLS FOR INSTALL OF INSTALLATION OF NEW FLOOR FINISH AND BASE TO MATCH
3'-0" X 7'-0"

3'-0" X 7'-0"
THE VERTICAL TRANSPORTATION WILL BE RESPONSIBILITY OF THE G.C. EXISTING.
TO REMOVE/REPAIR. COORDINATE WITH TENANT.
3'-8" X 7'-0"
ADMIN.
OFFICE Y. ANY TRENCHING OR DRILLING MUST BE COORDINATED WITH LANDLORD'S 18 ALL EXISTING, FIXTURES, FURNITURE, EQUIPMENT, ETC. TO REMAIN
118 REPRESENTATIVE PRIOR TO WORK. 'AS-IS' UNLESS OTHERWISE NOTED

THE MALL AT WELLINGTON GREEN


17 17 16
17

STORE NO. US 326 - RED MOD


Z. ANY EXISTING MATERIAL OF EQUIPMENT FINISHES REMAINING MUST BE

BLVD.WELLINGTON, FL. 33414


7 19 EXISTING WALL MOUNTED EQUIPMENT TO BE RELOCATED. VERIFY &
TIME REFURBISHED TO LIKE NEW.
CLOCK
CONFIRM EQUIPMENT RELOCATION IN FIELD WITH H&M PROJ. MGR. &
AA. VERIFY BARRICADE REQUIREMENT WITH MALL AND H&M TEAM

10300 W. FOREST HILL


4 T-WAVE T-WAVE REPRESENTATIVE.

VENDING

19
11
NOTES:
SINK

SUSP.
X-MER
18 COUCH

ALL EXISTING PARTITIONS TO BE PATCH AND REPAIRED AS REQUIRED

2024
CONCRETE PAD AFTER REMOVAL WORK FOR NEW LIKE CONDITION.
TRANS TRANS
FORMER FORMER

ALL DOORS ARE EXISTING UNLESS OTHER WISE NOTED.


TRASH PAPER PLASTIC
1125 1125
KVA KVA
REFRIG. MONITOR
MDP
VENDING

NEW
EXISTING EXISTING PROCESSING (W) TOILET (M) TOILET EXISTING EXISTING EXSTG. STAFF EX. ELEC.
MATCHLINE

MATCHLINE

STOCK RM. JAN. CL. AREA ROOM ROOM LAN ROOM STAFF AREA LOCKER AREA ROOM
AREA 'B'

AREA 'A'

125 124 123 122 121 120 120A 119


17 18 17 18 18 17 17 18 17 18 18

SHEET NO:
S T U
U.95
V

D-111
REV. NO:
REMOVAL FLOOR PLAN @ AREA 'B' 1
NORTH SCALE: 1/8" = 1'-0"

D.O.B. NO:
EGRESS TRAVEL DISTANCE EGRESS PLAN LEGEND
A ACTUAL TRAVEL DISTANCE = 90'-0" SYMBOL DESCRIPTION
B ACTUAL TRAVEL DISTANCE = 157'-10"
44" MIN. WIDE ACCESSIBLE MEANS OF EGRESS PATH
C ACTUAL TRAVEL DISTANCE = 209'-0"

*
D ACTUAL TRAVEL DISTANCE = 136'-0" EXIT POINT OF EGRESS PATH
E ACTUAL TRAVEL DISTANCE = 218'-4"
F ACTUAL TRAVEL DISTANCE = 207'-8" START POINT OF TRAVEL

G ACTUAL TRAVEL DISTANCE = 205'-5" EXIT SIGNS, WALL / CELING MOUNTED (ARROW REPRESENTS
DIRECTIONAL SIGN), TACTILE EXIT SIGNS TO BE FURNISHED BY
H
J
ACTUAL TRAVEL DISTANCE = 245'-6"
ACTUAL TRAVEL DISTANCE = 254'-0"
G.C. AS REQUIRED PER LOCAL AHJ; SEE RCP SHTS. JEFFREY
SAFE AREA DOOR SECURING DEVICE. G.C. TO FURNISH BACK TO
K ACTUAL TRAVEL DISTANCE = 23'-6" BACK STUD IN WALL FOR ATTACHMENT OF BARRICADE BOX.
REFER TO DOOR SCHEDULE SHT. FOR MORE INFO. TO BE
TAYLOR
L ACTUAL TRAVEL DISTANCE = 80'-7" INSTALLED IN ALL STOCKROOM DOORS.
ARCHITECT
M ACTUAL TRAVEL DISTANCE = 116'-0"
N ACTUAL TRAVEL DISTANCE = 130'-0"
EGRESS NOTES
1. MAINTAIN 3'-8" CLEAR PATH BETWEEN THE EXIT DOORS AT ALL TIMES.
572 NORTH BROADWAY
O ACTUAL TRAVEL DISTANCE = 160'-0"
MAINTAIN 3'-0" CLEAR PATH BETWEEN FLOOR FIXTURES. WHITE PLAINS, NEW YORK 10603
2. VERIFY EXIT SIGNS COORDINATE W/PATH OF EGRESS. REPORT ANY
DISCREPANCIES TO ARCHITECT / ENGINEER PRIOR TO ROUGH- IN.
TEL 914 289 0011
3. PER CODE. 'EXIT ACCESS TRAVEL DISTANCE', FOR OCCUPANCY 'M', TRAVEL
DISTANCE NOT TO EXCEED 250 FEET FOR BUILDINGS EQUIPPED
THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE
WITH CODE.

J.85 K K.34 K.9 L M N O P Q R S


3'-10" 8'-6" 13'-9" 2'-9" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0"

EXISTING NEW OPEN EXISTING


EXSTG. MENS
EXISTING NEW MENS MEN'S EXISTG. MENS LIGHTBOX LIGHTBOX OPEN WINDOW NEW MENS
MEN'S ENTRY OPEN WINDOW SALES AREA OPEN WINDOW WINDOW (WOMENS) WINDOW (KIDS) OPEN WINDOW
113
108 109 101 110 111 112 114

LIC # AR0015561
PT. 'A,B,C,G'
22.63

MATCHLINE

MATCHLINE
AREA 'B'

AREA 'A'
L
EXIT '2'
22.48 NEW MENS
OPEN WINDOW
107
15'-9"

22.3

22.2

22 EXP. 2/28/2025
EXISTING
DISPLAY WINDOW 6'-0"
106 REVISION:

6'-0"
6'-0"
25'-0"

NEW WOMENS " -11"


'-5 284'
OPEN WINDOW
70 D=
ERVE
105
AREA S
NC E OF
L D ISTA
ONA
DIAG
M

ISSUE DATE:
21
06.12.23 FOR REVIEW & APPROVALS
07.17.23 FOR BIDS & PERMITS
PT. 'A,D'
EXISTING
WOMENS ENTRY PT. 'B,E'
104
5'-11" 5'-8"
25'-0"

PT. 'D,E,F,H,J'

*
EXIT '1' ARCH PROJECT NO.: 10835
PRODUCT SEASON: 2024
SPACE NO.: 185
20 DRAWN BY: JTA
SCALE: AS NOTED
"
6'-0

EXSTG. WOMENS
OPEN WINDOW
SHEET TITLE:
6'-0"

6'-0"
103

EGRESS PLAN
AREA 'A'
25'-0"

PLASTIC
PAPER
TRASH

4'-0" X 7'-0"

THE MALL AT WELLINGTON GREEN


STORE NO. US 326 - RED MOD

BLVD.WELLINGTON, FL. 33414


19
MILLWORK
DECO TABLE
8'-4"

SERVICE
EXISTING

10300 W. FOREST HILL


SINK
HW
WOMENS 3'-0" X 7'-0"
SALES AREA
100 3'-4" X 7'-0" 3'-8" X 7'-0"

J.85 K K.34 K.9 L M N O

2024
PT. 'H' 2'-6"

P
NEW CLICK &
COLLECT STOCK
127

PT. 'K,L'

3'-8"

3'-8"
18

EXISTING NEW
EXISTING FITTING EXISTING EXISTING PROCESSING

MATCHLINE

MATCHLINE
STOCK RM. ROOM STOCK RM. JAN. CL. AREA

AREA 'B'

AREA 'A'
126
EXIT '4' 127 126 125 SHEET NO:
PT. 'K'

EXTERIOR A-110
REV. NO:
Q R S

D.O.B. NO:
EGRESS PLAN @ AREA 'A' 1
SCALE: 1/8" = 1'-0"
NORTH
EGRESS TRAVEL DISTANCE EGRESS PLAN LEGEND
A ACTUAL TRAVEL DISTANCE = 90'-0" SYMBOL DESCRIPTION
B ACTUAL TRAVEL DISTANCE = 157'-10"
44" MIN. WIDE ACCESSIBLE MEANS OF EGRESS PATH
C ACTUAL TRAVEL DISTANCE = 209'-0"

*
D ACTUAL TRAVEL DISTANCE = 136'-0" EXIT POINT OF EGRESS PATH
E ACTUAL TRAVEL DISTANCE = 218'-4"
F ACTUAL TRAVEL DISTANCE = 207'-8" START POINT OF TRAVEL

G ACTUAL TRAVEL DISTANCE = 205'-5" EXIT SIGNS, WALL / CELING MOUNTED (ARROW REPRESENTS
DIRECTIONAL SIGN), TACTILE EXIT SIGNS TO BE FURNISHED BY
H
J
ACTUAL TRAVEL DISTANCE = 245'-6"
ACTUAL TRAVEL DISTANCE = 254'-0"
G.C. AS REQUIRED PER LOCAL AHJ; SEE RCP SHTS. JEFFREY
SAFE AREA DOOR SECURING DEVICE. G.C. TO FURNISH BACK TO
K ACTUAL TRAVEL DISTANCE = 23'-6" BACK STUD IN WALL FOR ATTACHMENT OF BARRICADE BOX.
REFER TO DOOR SCHEDULE SHT. FOR MORE INFO. TO BE
TAYLOR
L ACTUAL TRAVEL DISTANCE = 80'-7" INSTALLED IN ALL STOCKROOM DOORS.
ARCHITECT
M ACTUAL TRAVEL DISTANCE = 116'-0"
N ACTUAL TRAVEL DISTANCE = 130'-0"
EGRESS NOTES
1. MAINTAIN 3'-8" CLEAR PATH BETWEEN THE EXIT DOORS AT ALL TIMES.
572 NORTH BROADWAY
O ACTUAL TRAVEL DISTANCE = 160'-0"
T U V MAINTAIN 3'-0" CLEAR PATH BETWEEN FLOOR FIXTURES. WHITE PLAINS, NEW YORK 10603
25'-0" 25'-0" 23'-6" 1'-6" 2. VERIFY EXIT SIGNS COORDINATE W/PATH OF EGRESS. REPORT ANY
DISCREPANCIES TO ARCHITECT / ENGINEER PRIOR TO ROUGH- IN.
TEL 914 289 0011
3. PER CODE. 'EXIT ACCESS TRAVEL DISTANCE', FOR OCCUPANCY 'M', TRAVEL
DISTANCE NOT TO EXCEED 250 FEET FOR BUILDINGS EQUIPPED
THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE
EXISTG. KIDS EXISTG. KID'S WITH CODE.
OPEN WINDOW SALES AREA OPEN WINDOW
102 116

MATCHLINE

MATCHLINE
AREA 'B'

AREA 'A'
MALL
(2)3'-0" X 7'-0"
LIC # AR0015561
H.M. DOOR
22.8
22.1

PT. 'C,O'

EXP. 2/28/2025

REVISION:

5'-11"

ISSUE DATE:

EGRESS CORRIDOR
06.12.23 FOR REVIEW & APPROVALS
07.17.23 FOR BIDS & PERMITS

PT. 'J,M' ARCH PROJECT NO.: 10835


PRODUCT SEASON: 2024
SPACE NO.: 185
DRAWN BY: JTA
PLASTIC

SCALE: AS NOTED
PAPER
TRASH

MGR./SECR.
OFFICE SHEET TITLE:
117
EGRESS PLAN
4'-0" X 7'-0"

SAFE
LAN
RACK
AREA - 'B'
8'-4"
3'-0" X 7'-0"
SERVICE
SINK

HW

3'-0" X 7'-0"
3'-0" X 7'-0"

3'-8" X 7'-0"
ADMIN.
5'-6"

HI-LO
OFFICE

*
DRINKING
FOUNTAIN
118

6'-1"
TIME
EXIT '3' PT. 'M,N,O'

THE MALL AT WELLINGTON GREEN


CLOCK

STORE NO. US 326 - RED MOD

BLVD.WELLINGTON, FL. 33414


T-WAVE T-WAVE

LOCKERS

10300 W. FOREST HILL


LOCKERS
SINK

SUSP.
X-MER
COUCH

CONCRETE PAD
COAT TRANS TRANS
HANGER FORMER FORMER

2024
TRASH PAPER PLASTIC
1125 1125
KVA KVA
REFRIG. MONITOR
MDP
VENDING

PT. 'L'
NEW
EXISTING PROCESSING (W) TOILET (M) TOILET EXISTING EXISTING EXSTG. STAFF EX. ELEC.
MATCHLINE

MATCHLINE

JAN. CL. AREA ROOM ROOM LAN ROOM STAFF AREA LOCKER AREA ROOM
AREA 'B'

AREA 'A'

124 123 122 121 120 120A 119

T U V SHEET NO:

A-111
REV. NO:
EGRESS PLAN @ AREA 'B' 1
SCALE: 1/8" = 1'-0"
NORTH

D.O.B. NO:
NOTE: REFER

TO SHT. A-211 FOR DIMENSION PLAN.

SYMBOL LEGEND
SYMBOL DESCRIPTION

PARTITION TYPE -
REFER TO SHEET PARTITION TYPES SHEET

EX
EXISTING DOOR AND HARDWARE TO REMAIN - NO
CHANGE
JEFFREY
X
NEW DOOR NUMBER -
REFER TO DOOR SCHEDULE SHEET
TAYLOR
ARCHITECT
ELEVATION TAG

572 NORTH BROADWAY


X
DETAIL TAG
XX WHITE PLAINS, NEW YORK 10603
X CONSTRUCTION TAG NOTE
TEL 914 289 0011

KEY NOTES
# DESCRIPTION
EXISTING FLOORING TO REMAIN THROUGHOUT SALES AREA, CLEAN &
1
J.85 K K.34 K.9 L M N O P Q R S POLISH AS REQUIRED.

3'-10" 8'-6" 13'-9" 2'-9" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" G.C. TO PATCH AND REPAIR FLOOR, WHERE WALL HAS BEEN DEMOLISHED, TO
2
MATCH AND ALIGN WITH EXISTING.

ALL DOORS AND FRAMES AT SALES AREA FLOOR (NEW CLICK & COLLECT
3
EXISTING NEW OPEN EXISTING STORAGE AREA) TO BE PAINTED TO MATCH ADJACENT WALL.
EXSTG. MENS
EXISTING NEW MENS MEN'S EXISTG. MENS LIGHTBOX LIGHTBOX OPEN WINDOW NEW MENS G.C. TO FURNISH AND INSTALL NEW 4' H. 'INPRO' CORNER GUARDS AT
MEN'S ENTRY OPEN WINDOW SALES AREA OPEN WINDOW WINDOW (WOMENS) WINDOW (KIDS) OPEN WINDOW 4
113 EXPOSED CORNERS OF SALES AREA WALLS & COLUMNS. REFER TO CORNER
108 109 101 110 4 111 112 114
GUARD COLOR SCHEDULE & DETAIL ON FINISH PLANS FOR MORE INFO.
A600 HANDICAPPED CASHWRAP FURNISHED BY H&M AND INSTALLED BY G.C. 3'-0"
41'-11"± 5
CLEAR REQUIRED BETWEEN FACE OF WARDROBE UNITS AND FACE OF
APPROX. LENGTH OF 9'-11 5 CASHWRAPS FOR TOTAL LENGTH OF LAYOUT. 5'-0" CLEAR WIDTH REQUIRED
3 APPR "±
14'-7"± 23'-1"± 2'-11" CURTAIN TRACK O
OF CU X. LENGT A600
AREA IF ACCESS IS FROM ONE SIDE. HEIGHT OF COUNTER TOP TO COMPLY
A600 9'-2" 8'-5" 9'-2" RTAIN H
APPROX. LENGTH OF APPROX. LENGTH OF TRAC
WITH ICC/ANSI A117.1, SECTION 904 AND ADA AG. REFER TO FIXTURE SHTS.
CURTAIN TRACK CURTAIN TRACK 7'-2 3/4" H. 7'-2 3/4" H. K FOR MORE INFORMATION.
17 21 17
LIC # AR0015561
6 NEW WARDROBE FIXTURES AT NEW SALES AREA WALL
21
19 21 21 21
L L L L L
22.63 ALIGN CURTAIN 7 NEW SECTION OF WALL, WHERE DOORS HAVE BEEN REMOVED, TO

MATCHLINE

MATCHLINE
1'-8"
MATCH AND ALIGN WITH ADJACENT CONSTRUCTION

AREA 'B'

AREA 'A'
L L L L L L

1'-8"
L WITH EDGE OF
NEW MENS 15 COLUMN NEW WARDROBE FIXTURES AT NEW SALES AREA WALL
22.48 8
OPEN WINDOW 13 13 14 ALIGN CURTAIN 21
107 EX 15 WITH EDGE OF
NEW SECTION OF WALL, WHERE DOORS HAVE BEEN REMOVED, TO
15'-9"

COLUMN 9
22.3 N
MATCH AND ALIGN WITH ADJACENT CONSTRUCTION
ALIG 11
18 (TYP.) 10 ROOM DIVIDER CURVED SHEET AND SUPPORT TUBES (SUPPORT TUBES
"
-7

22.2 L TO BE INSTALLED FACING BACK OF STORE. FURNISHED BY H&M AND


7'

E
1 L INSTALLED BY G.C. REFER TO CURTAIN TRACK DETAIL 6/A702 FOR MORE INFO.
2
7 2'-0" M M A-702 NEW M
14'-8
"± 13 14 11 EXISTING DROPPED GYP. BD. SOFFIT AT STOREFRONT ENTRY TO REMAIN
22 A600 A-702 2' CASHPOINT APPR EXP. 2/28/2025
-3 OX. L
" OF CU E
EXISTING E1 11 M RTAIN NGTH NEW DROPPED GYP. BD. SOFFIT AT STOREFRONT ENTRY TO MATCH AND
TRAC 12
N

M
K ALIGN WITH EXISTG. SOFFIT AND EDGE OF NEW MODIFIED STOREFRONT
IG

DISPLAY WINDOW 16 REVISION:


AL

106 BUILD-OUT
M TYP.
IU HATCHED AREA INDICATES NEW GYP. BD. CEILING / SOFFIT

D 7 13
'-8

PO CONSTRUCTION TO MATCH AND ALIGN WITH ADJACENT CEILING


24

D
IE
IF E HATCHED AREA INDICATES NEW FLOORING TO MATCH AND ALIGN WITH
D
M
O 1 2 3 4 15 16 14 ADJACENT FLOOR FINISH, AS REQD.
N
IG
N
IG
25'-0"

AL

E EXISTING COVE OPENING TO REMAIN THROUGHOUT SALES AREA - PATCH


AL

13 14 15 AND REPAIR WHERE REQD. AND PAINT TO MATCH EXISTING. WHEN


NEW WOMENS
OPEN WINDOW TRENCHING / CORE DRILLING IS REQD. IT IS TENANTS G.C. RESPONSIBILITY
E TO XREY / SCAN THE EXISTING SLAB PRIOR TO DEMOLITION OR
105 M
6 CONSTRUCTION TO VERIFY LOCATION OF UNDERGROUND UTILITIES.
"
-6
9' 6
"

G.C. TO PATCH & REPAIR EXISTING COLUMN ENCLOSURE AND PREPARE


-8

13 16
1'

7 FOR NEW PAINT FINISH (MAINTAIN FIRE RATINGS ON ALL COLUMNS) SEE
E1

A-702 14 14 E FINISH PLAN FOR ADDTL. INFO.) ALL EXISTING FIXTURES, MIRRORS, SIGNAGE,
'-1 ETC. SHALL BE REMOVED AND STORED FOR REINSTALLATION AFTER COLUMN
13
"

2' 1" ISSUE DATE:


-8

-3
1'

21 " M M M M REFINISHING, COORDINATE WITH H&M PROJECT MANGER.


15 06.12.23 FOR REVIEW & APPROVALS
6 NEW FREE-STANDING LIGHTBOX LOCATION - G.C. TO COORDINATE
17
13 14 A-702 (TYP.) ELECTRICAL CONNECTIONS AS REQD. RE-USE EXISTING WIRING AND 07.17.23 FOR BIDS & PERMITS
APPROX. LENGTH OF

APPROX. LENGTH OF
MTL. DIVIDER CURTAIN

15

MTL. DIVIDER CURTAIN


CIRCUIT FROM REMOVED LIGHTBOX. COORDINATE FINAL LIGHTBOX

APPROX. LENGTH OF
MTL. DIVIDER CURTAIN
E
"

EXISTING
2'-0

LOCATION WITH H&M PROJECT MANGER PRIOR TO INSTALLATION.


WOMENS ENTRY 10

14'-0"±

14'-0"±
2'-8
12'-6"±

104 12 10
E1

"± EXISTING 'SENSORMATIC' PEDESTALS TO REMAIN, CHECKED FOR


11'-4"±

11'-4"±
10 18

9'-9"±
PROPER OPERATION AND THOROUGHLY CLEANED AFTER
CONSTRUCTION.
18 (TYP.)
25'-0"

19 EXISTING ROLL-UP GRILLE AND RELATED HARDWARE TO REMAIN,


CHECKED FOR PROPER OPERATION AND THOROUGHLY CLEANED AFTER
15
CONSTRUCTION.
1 EX
19 ALIGN ENDS OF TRACK ALIGN ENDS OF TRACK NEW FITTING ROOM SERVICE AREA PARTIAL HEIGHT WALL TO BE
A600 20
CAPPED AND ALIGN WITH HEIGHT OF FITTING ROOM WALLS - ARCH PROJECT NO.: 10835
11 COORDINATE HEIGHT WITH H&M PROJECT MANAGER.
PRODUCT SEASON: 2024
21 NEW CEILING MOUNTED SHEER CURTAIN AND RAIL - MOUNTED DIRECTLY
TO GYP. BD. CEILING COORDINATE EXACT LOCATION IN FIELD SEE SPACE NO.: 185
20
DETAIL 1/A750 AND H&M BUILDING STANDARDS FOR ADDITIONAL INFO. DRAWN BY: JTA
M M M M M
M M
NEW 6" HEAVY DUTY SATIN FINISHED SLIDE BOLT LATCH AT EXISTING SCALE: AS NOTED
L

22
BOH DOOR BY 'ROCKWOOD' OR APPROVED EQUAL
16

APPROX. LENGTH OF
MTL. DIVIDER CURTAIN
EXSTG. WOMENS TYP.
OPEN WINDOW
NOTES:
L

103 3'-6
21 8'-1"± SHEET TITLE:
" ALIGN ENDS OF TRACK

11'-4"±
6 (TYP.)
ALL EXISTING PARTITIONS TO BE PATCHED AND REPAIRED AS REQUIRED, CONSTRUCTION PLAN
1 2 3 4 15 16 10 TO MATCH AND ALIGN WITH EXISTING AFTER REMOVAL WORK TO 'LIKE -
AREA - 'A'
APPROX. LENGTH OF

APPROX. LENGTH OF

A-702
MTL. DIVIDER CURTAIN

MTL. DIVIDER CURTAIN


25'-0"

NEW' CONDITION.
APPROX. LENGTH 5G

PLASTIC
OF CURTAIN TRACK A702
ALL DOORS AND HARDWARE ARE EXISTING UNLESS OTHER WISE NOTED.
±
L

11'-4"±
-9"

11'-4±

PAPER
12'-6"±

13'-11"±
24'

4F GYPSUM BOARD FINISH MUST BE LEVEL (4) FOR ALL PARTITIONS.


10

TRASH
A702
10
1 GYPSUM BOARD FINISH MUST BE LEVEL (4) FOR ALL CEILING
B2 ALIGN A-730
ALIGN
15 13 ALIGN CONSTRUCTION.

4'-0" X 7'-0"
EX

THE MALL AT WELLINGTON GREEN


G.C. TO FURNISH (1) HOUR FIRE RATING (MIN.) INCLUDING DOORS AT ALL

STORE NO. US 326 - RED MOD

BLVD.WELLINGTON, FL. 33414


19 RATED WALLS SHOWN ON CONSTRUCTION PLAN.
E
3'-4" 2'-2"

MILLWORK
E1 DECO TABLE
Q Q SEE DRAWING A-500's FOR ADDITIONAL FINISH INFORMATION.

SERVICE
EXISTING

10300 W. FOREST HILL


12'-5" 5 16 5 EX

SINK
WOMENS 3'-10" HW
3'-0" X 7'-0"
SALES AREA G1 G1 TYP. ALIGN
100
100 3'-4" X 7'-0" 3'-8" X 7'-0"
SEE "EX" DRAWINGS FOR ADDITIONAL EXISTING DIMENSIONS.
J.85 K K.34 K.9 L M N O 20
N3 EX

5'-5"
ALIGN E1

BARRICADE NOTE:

2024
G1
3 2 Q3
A-761 NEW A-702 2'-6"
GC MUST PROVIDE, INSTALL AND REMOVE ANY REQUIRED CONSTRUCTION BARRICADE
P

SAMPLE WALL
CASHPOINT MANNEQUIN / AT PROJECT WORK AREAS AS REQUIRED PER CODE AND PER MALL MANAGEMENT
NEW CLICK & PROP STORAGE
COLLECT STOCK REQUIREMENTS.
127 COORDINATE BARRICADE INSTALLATION WITH MALL MANAGEMENT.

FACILITIES
G1 G1 VISUAL
CHECK-IN
EX
18

EXISTING NEW
EXISTING FITTING EXISTING EXISTING PROCESSING

MATCHLINE

MATCHLINE
STOCK RM. ROOM STOCK RM. JAN. CL. AREA

AREA 'B'

AREA 'A'
126 127 126 125 SHEET NO:

EXTERIOR A-210
REV. NO:
Q R S

REFER TO H&M FURNISHED "IPS DRAWINGS AND


COORDINATE WITH H&M STORE INSTALLATION,
INSTRUCTION & CONSTRUCTION MANUALS. D.O.B. NO:
CONSTRUCTION FLOOR PLAN @ AREA 'A' 1
COORDINATE WITH FIXTURE VENDOR AND H&M
SCALE: 1/8" = 1'-0"
NORTH PROJECT MGR. FOR ADDITIONAL INFORMATION.
CONSTRUCTION GENERAL NOTES NOTE: REFER

TO SHT. A-211 FOR DIMENSION PLAN.


1. G.C. IS RESPONSIBLE TO FIELD-VERIFY ALL EXISTING CONDITIONS &
DIMENSIONS IN THE SPACE. FAILURE TO PROPERLY VERIFY EXISTING
CONDITIONS DOES NOT RELIEVE G.C. OF ANY EXPENSES OR SYMBOL LEGEND
RESPONSIBILITIES RESULTING FROM THAT FAILURE.
SYMBOL DESCRIPTION
2. CONTRACTOR TO FURNISH PARTITION LAYOUT FOR ARCHITECT'S/ H&M'S
APPROVAL BEFORE CONSTRUCTION FOR CONFIRMATION OF ALL
DIMENSIONS. G.C. TO COORDINATE ALL DIMENSIONS WITH H&M FIXTURE PARTITION TYPE -
DIMENSIONS. REFER TO SHEET PARTITION TYPES SHEET
3. NOT USED.

4. G.C. TO FURNISH SHOP DRAWINGS FOR ARCHITECT'S APPROVAL BEFORE


FABRICATION OF ALL FINISHES, HARDWARE & COMPONENTS. SEE SHOP DWG. EX
EXISTING DOOR AND HARDWARE TO REMAIN - NO
CHANGE
JEFFREY
LIST ON GENERAL NOTES & RESPONSIBILITY SCHEDULE SHEET.

5. IN CASE OF DISCREPANCY BETWEEN ARCHITECT'S & ENGINEER'S DRAWINGS, X


NEW DOOR NUMBER -
REFER TO DOOR SCHEDULE SHEET
TAYLOR
THE MORE STRINGENT, HIGHER QUANTITY OR HIGHER QUALITY SHALL
PREVAIL. CONTRACTOR TO INFORM ARCHITECT & H&M PROJECT MANAGER
OF ANY DISCREPANCIES PRIOR TO SUBMITTING BID.
ARCHITECT
ELEVATION TAG
6. G.C. TO VERIFY ALL DIMENSIONS OF MILLWORK, FIXTURES & FITTING ROOMS
WITH H&M PRIOR TO LAYOUT.
572 NORTH BROADWAY
7. G.C. TO PATCH, REPAIR AS REQUIRED & PAINT ALL GYP. BD. COLUMN WRAPS X
DETAIL TAG
T U V & EXPOSED AREAS AT EXISTING WINDOW WALLS & ALL EXISTING GYP. BD. XX WHITE PLAINS, NEW YORK 10603
25'-0" 25'-0" 23'-6" 1'-6" 8. G.C. TO COORDINATE CONSTRUCTION TIMING WITH H&M SCHEDULE PRIOR
TO CONSTRUCTION START. ANY CHANGE TO CONSTRUCTION SCHEDULE X CONSTRUCTION TAG NOTE
MUST BE SENT TO H&M PM FOR REVIEW & APPROVAL. TEL 914 289 0011
9. ALL PLYWOOD BACKING / BLOCKING IS FIRE RESISTANT (F.R.) / FIRE
EXISTG. KIDS EXISTG. KID'S
RETARDANT TREATED (FRT). KEY NOTES
OPEN WINDOW SALES AREA OPEN WINDOW
10. G.C. IS RESPONSIBLE FOR PROVIDING ALL BRACING /BLOCKING AS REQUIRED # DESCRIPTION
102 116 BY CODE & STRUCTURAL NECESSITY FOR ALL FIXTURES AFFIXED TO WALLS
AND CEILINGS. SEE FIXTURE DETAILS & PARTITION TYPES FOR CONNECTION EXISTING FLOORING TO REMAIN THROUGHOUT SALES AREA, CLEAN &
DETAILS. 1
POLISH AS REQUIRED.
11. NOT USED. G.C. TO PATCH AND REPAIR FLOOR, WHERE WALL HAS BEEN DEMOLISHED, TO
2
MATCH AND ALIGN WITH EXISTING.
12. ALL WORK TO COMPLY WITH ALL APPLICABLE LOCAL, STATE & FEDERAL
BY-LAWS & CODE REQUIREMENTS.
ALL DOORS AND FRAMES AT SALES AREA FLOOR (NEW CLICK & COLLECT
3
13. G.C. TO PROTECT & MAINTAIN EXISTING FIRE PROOFING AROUND COLUMN & STORAGE AREA) TO BE PAINTED TO MATCH ADJACENT WALL.
BEAMS & ALL STRUCTURAL MEMBERS TYPICAL THROUGHOUT.
REPAIR/REPLACE ANY DAMAGED FIREPROOFING AS REQ'D. DUE TO G.C. TO FURNISH AND INSTALL NEW 4' H. 'INPRO' CORNER GUARDS AT
6 CONSTRUCTION. 4 EXPOSED CORNERS OF SALES AREA WALLS & COLUMNS. REFER TO CORNER
A600 GUARD COLOR SCHEDULE & DETAIL ON FINISH PLANS FOR MORE INFO.
ALIGN CURTAIN 14. G.C. TO MATCH NEW FIREPROOFING WITH EXISTING, WHERE REQD..

MATCHLINE

MATCHLINE
HANDICAPPED CASHWRAP FURNISHED BY H&M AND INSTALLED BY G.C. 3'-0"

AREA 'B'

AREA 'A'
WITH EDGE OF 5
15. EXISTING STRUCTURAL SLAB SHALL NOT BE TRENCHED, CUT OR DAMAGED IN CLEAR REQUIRED BETWEEN FACE OF WARDROBE UNITS AND FACE OF
COLUMN
ANY WAY WITHOUT WRITTEN DIRECTION FROM STRUCTURAL E.O.R. & CASHWRAPS FOR TOTAL LENGTH OF LAYOUT. 5'-0" CLEAR WIDTH REQUIRED
APPROVAL BY THE LANDLORD. AREA IF ACCESS IS FROM ONE SIDE. HEIGHT OF COUNTER TOP TO COMPLY
WITH ICC/ANSI A117.1, SECTION 904 AND ADA AG. REFER TO FIXTURE SHTS.
16. G.C. TO FURNISH ALL NECESSARY SIGNS (INCL. THOSE PER CODE FOR
ACCESSIBILITY) FOR TOILETS, FITTING ROOMS, STAIRS, ELEVATORS (AS FOR MORE INFORMATION.
MALL
REQ'D.). LIC # AR0015561
(2)3'-0" X 7'-0"
H.M. DOOR 6 NEW WARDROBE FIXTURES AT NEW SALES AREA WALL
L 22.8 17. G.C. TO FURNISH ALL SALES AND BOH CORNER GUARDS.
L
18. G.C. IS SOLELY RESPONSIBLE TO TEST MOISTURE CONTENT OF SUB-FLOOR NEW SECTION OF WALL, WHERE DOORS HAVE BEEN REMOVED, TO
22.1 PRIOR TO INSTALLATION OF ALL FINISH FLOORING MATERIALS & MAINTAIN 7
13 14 MATCH AND ALIGN WITH ADJACENT CONSTRUCTION
APPR PROPER TEMPERATURE & HUMIDITY LEVELS PER MANUFACTURERS
OF CU OX. LENGT SPECIFICATIONS.
RTAIN H 8 NEW WARDROBE FIXTURES AT NEW SALES AREA WALL
TRAC M
K 19. NOTHING IS PERMITTED TO ATTACH TO, SUSPENDED FROM, OR PENETRATE
ROOF DECK. G.C. MAY ONLY ATTACH TO TOP CHORD OF JOIST(S) OR I-BEAMS NEW SECTION OF WALL, WHERE DOORS HAVE BEEN REMOVED, TO
PER LANDLORD REQUIREMENT. ALL WALL/CLG./OVERHEAD CONSTRUCTION 9
MATCH AND ALIGN WITH ADJACENT CONSTRUCTION
TO BE SUPPORTED IN THIS MANNER. NO WELDING OR SHOOTING INTO
STRUCTURE IS PERMITTED. COORDINATE EXTENT OF EXACT REQUIREMENTS
WITH LANDLORD'S REP. 10 ROOM DIVIDER CURVED SHEET AND SUPPORT TUBES (SUPPORT TUBES
TO BE INSTALLED FACING BACK OF STORE. FURNISHED BY H&M AND
20. ANY EXISTING LANDLORD EQUIPMENT OR COMPONENT EXISTING IN THE INSTALLED BY G.C. REFER TO CURTAIN TRACK DETAIL 6/A702 FOR MORE INFO.
SPACE MUST REMAIN VISIBLE & ACCESSIBLE. G.C. TO COORD. ANY REQ'D
ACCESS W/H&M PM, LANDLORD REP. & ARCHITECT.
11 EXISTING DROPPED GYP. BD. SOFFIT AT STOREFRONT ENTRY TO REMAIN EXP. 2/28/2025
21. ALL CONCRETE PATCHING MUST BE LEVEL WITH EXISTING CONCRETE FLOOR. NEW DROPPED GYP. BD. SOFFIT AT STOREFRONT ENTRY TO MATCH AND
M
12 ALIGN WITH EXISTG. SOFFIT AND EDGE OF NEW MODIFIED STOREFRONT
22. G.C. TO INSTALL ALL ELECTRICAL DEVICES & EQUIPMENT AT CENTERLINE OF
COLUMN FACE, TYP., U.O.N. SEE MEP DRAWINGS. BUILD-OUT REVISION:
HATCHED AREA INDICATES NEW GYP. BD. CEILING / SOFFIT
23. DO NOT SCALE THESE DRAWINGS. USE WRITTEN DIMENSIONS ONLY. SUBMIT 13
TO ARCHITECT ANY DISCREPANCIES FOR CLARIFICATION. REFER TO CONSTRUCTION TO MATCH AND ALIGN WITH ADJACENT CEILING
RESPONSIBILITY SCHEDULE. HATCHED AREA INDICATES NEW FLOORING TO MATCH AND ALIGN WITH
14 ADJACENT FLOOR FINISH, AS REQD.
24. FURNISH ACCESSIBILITY FOR PHYSICALLY HANDICAPPED PER (LOCAL
M M M
ACCESSIBILITY CODE). EXISTING COVE OPENING TO REMAIN THROUGHOUT SALES AREA - PATCH
15 AND REPAIR WHERE REQD. AND PAINT TO MATCH EXISTING. WHEN
25. G.C. TO ENSURE ALL INTERIOR WALL BLOCKING IS INSTALLED PRIOR TO
APPLYING WALL FINISHES. COORDINATE LOCATION OF BLOCKING WITH H&M TRENCHING / CORE DRILLING IS REQD. IT IS TENANTS G.C. RESPONSIBILITY
FIXTURE MANUFACTURERS. TO XREY / SCAN THE EXISTING SLAB PRIOR TO DEMOLITION OR
CONSTRUCTION TO VERIFY LOCATION OF UNDERGROUND UTILITIES.
26. ALL FLOOR ELECTRICAL BOXES TO BE INSTALLED FLUSH W/ NEW FLOORING
1 2 3 4 16 AT CASHWRAP & FIXTURES W/ POWER AS SHOWN ON ELECTRICAL SHEETS. G.C. TO PATCH & REPAIR EXISTING COLUMN ENCLOSURE AND PREPARE
REFER TO FLOOR & MISC. DETAILS SHEET & ELECTRICAL DRAWINGS. 16
FOR NEW PAINT FINISH (MAINTAIN FIRE RATINGS ON ALL COLUMNS) SEE
27. ALL GYP. BD. SURFACES TO BE A LEVEL (4) FINISH PRIOR TO PAINTING. FINISH PLAN FOR ADDTL. INFO.) ALL EXISTING FIXTURES, MIRRORS, SIGNAGE,
ETC. SHALL BE REMOVED AND STORED FOR REINSTALLATION AFTER COLUMN ISSUE DATE:
REFINISHING, COORDINATE WITH H&M PROJECT MANGER.

EGRESS CORRIDOR
28. SAW CUTTING (ALLOWED IN SLAB-ON-GROUND CONDITIONS ONLY) & CORE
DRILLING MUST OCCUR OUTSIDE OF MALL OPERATING HOURS. COORD. W/ 06.12.23 FOR REVIEW & APPROVALS
MALL'S REP. NEW FREE-STANDING LIGHTBOX LOCATION - G.C. TO COORDINATE
17
E ALL
ELECTRICAL CONNECTIONS AS REQD. RE-USE EXISTING WIRING AND 07.17.23 FOR BIDS & PERMITS
29. ALL FLOOR PENETRATIONS MUST BE SLEEVED & SEALED LIQUID TIGHT. CIRCUIT FROM REMOVED LIGHTBOX. COORDINATE FINAL LIGHTBOX
SIDES
FIRE-STOPPING IS REQUIRED USING APPROPRIATE UL METHOD. LOCATION WITH H&M PROJECT MANGER PRIOR TO INSTALLATION.

ALIGN

ALIGN
1'-10"± 30. ALL PLYWOOD BACKING/BLOCKING IS FIRE RESISTANT. G.C. RESPONSIBLE
FOR PROVIDING ALL BRACINGS/BLOCKING REQUIRED BY CODE AND EXISTING 'SENSORMATIC' PEDESTALS TO REMAIN, CHECKED FOR
18
STRUCTURAL NECESSITY FOR ALL FIXTURES, SIGNAGE, LIGHTING, ETC. PROPER OPERATION AND THOROUGHLY CLEANED AFTER

2'-10"
AFFIXED TO WALLS AND CEILINGS. ALL EXPOSED HOOD TRIM IS NOT CONSTRUCTION.
REQUIRED TO BE FRT
19 EXISTING ROLL-UP GRILLE AND RELATED HARDWARE TO REMAIN,
31. G.C. IS RESPONSIBLE FOR STORAGE OF ALL DELIVERED MATERIALS, CHECKED FOR PROPER OPERATION AND THOROUGHLY CLEANED AFTER
FIXTURES, ETC. DURING CONSTRUCTION OF STORE. G.C. HAS 48 HOURS CONSTRUCTION.
UPON RECEIPT OF ANY ITEM TO CHECK-IN SAID ITEM & NOTE ANY DAMAGE OF
ITEM. G.C. TO NOTIFY H&M OF ANY DAMAGED ITEM(S) WITHIN THIS 48 HOUR 20 NEW FITTING ROOM SERVICE AREA PARTIAL HEIGHT WALL TO BE
8'-1"± PERIOD. IF NO NOTIFICATION OCCURS WITHIN THE 48 HOUR PERIOD, G.C. 10835
ASSUMES RESPONSIBILITY FOR CONDITION OF ITEM.
CAPPED AND ALIGN WITH HEIGHT OF FITTING ROOM WALLS - ARCH PROJECT NO.:
COORDINATE HEIGHT WITH H&M PROJECT MANAGER.
PRODUCT SEASON: 2024
10 32. G.C. TO BEGIN CONSTRUCTION OF LEASED SPACE WITH INSTALLATION OF NEW CEILING MOUNTED SHEER CURTAIN AND RAIL - MOUNTED DIRECTLY
FLOOR TILE, (WHERE APPLICABLE), AFTER DEMOLITION IS COMPLETED IN 21 SPACE NO.: 185
TO GYP. BD. CEILING COORDINATE EXACT LOCATION IN FIELD SEE
PHASE. ALL OTHER NEW CONSTRUCTION SHALL OCCUR ON TOP OF FLOOR
5G
TILE. AFTER FLOOR TILE HAS BEEN INSTALLED G.C. TO COVER TILE TO DETAIL 1/A750 AND H&M BUILDING STANDARDS FOR ADDITIONAL INFO. DRAWN BY: JTA
PLASTIC

A702 PROTECT AS REQUIRED. AFTER FLOOR TILE HAS BEEN INSTALLED G.G. SHALL
NEW 6" HEAVY DUTY SATIN FINISHED SLIDE BOLT LATCH AT EXISTING SCALE: AS NOTED
PAPER

NOT ALLOW THE USE OF LIFTS FOR ANY FURTHER CONSTRUCTION OF THE 22
4F LEASED SPACE. BOH DOOR BY 'ROCKWOOD' OR APPROVED EQUAL
TRASH

A702
33. WARDROBE TOP CONNECTORS TO BE INSTALLED BEHIND WARDROBE
MGR./SECR.
OFFICE
HEADER CONNECTORS AND NOT TO BE EXPOSED TO SALES FLOOR.
NOTES: SHEET TITLE:
117 34. ALL PLUMBING WALLS ARE TO BE 6" METAL STUD CONSTRUCTION.
4'-0" X 7'-0"

SAFE
EX
ALL EXISTING PARTITIONS TO BE PATCHED AND REPAIRED AS REQUIRED, CONSTRUCTION PLAN
35. DRYWALL AT DEMISING WALLS MUST CONTINUE TO METAL DECK (MUST BE TO MATCH AND ALIGN WITH EXISTING AFTER REMOVAL WORK TO 'LIKE -
LAN
RACK
FIRE TAPED OR FIRE CAULKED TO DECK AS REQ'D BY CODE). ABOVE, TO BE NEW' CONDITION.
AREA - 'B'
TAPED & PRIMED TO ABOVE FINISH CEILING ELEVATION OR DESIGNATED
22
3'-0" X 7'-0"

SALES AREA HT IN OPEN CLG.


SERVICE

EX
SINK

HW ALL DOORS AND HARDWARE ARE EXISTING UNLESS OTHER WISE NOTED.

3'-0" X 7'-0"
3'-0" X 7'-0"
36. ALL WORK SHALL BE IN LOCAL COMPLIANCE W/ ADOPTED LOCAL CODES, AIA
EX A-210 CONDITIONS OF CONTRACT FOR CONSTRUCTION, RECOGNIZED GYPSUM BOARD FINISH MUST BE LEVEL (4) FOR ALL PARTITIONS.
3'-8" X 7'-0"
ADMIN. INDUSTRY STANDARDS IN THE AREA, ALL MANUFACTURERS
EX HI-LO
DRINKING EX EX EX EX OFFICE RECOMMENDATIONS, & ALL OTHER APPLICABLE CODES.
FOUNTAIN

EX 118 GYPSUM BOARD FINISH MUST BE LEVEL (4) FOR ALL CEILING
37. G.C. TO VERIFY WITH LANDLORD THE MAXIMUM DEPTH OF ANY CONSTRUCTION.
G1 TIME PENETRATIONS OR ANCHORS INTO THE SLAB BEFORE SLAB WORK BEGINS.

THE MALL AT WELLINGTON GREEN


CLOCK EX
G.C. TO FURNISH (1) HOUR FIRE RATING (MIN.) INCLUDING DOORS AT ALL
38. ALL LARGE SALES AREA FIXTURES OVER 5'-9" H. TO BE PROPERLY SECURED

STORE NO. US 326 - RED MOD

BLVD.WELLINGTON, FL. 33414


MANNEQUIN / T-WAVE T-WAVE TO FLOOR OR WALL. RATED WALLS SHOWN ON CONSTRUCTION PLAN.

LOCKERS
PROP STORAGE
39. G.C. RESPONSIBILITY TO ENSURE THAT THERE IS ADEQUATE ACCESS INTO SEE DRAWING A-500's FOR ADDITIONAL FINISH INFORMATION.

10300 W. FOREST HILL


PROCESSING AREA

SPACE FOR ALL LARGE FIXTURES.

LOCKERS
SINK

SUSP.
X-MER
SEE "EX" DRAWINGS FOR ADDITIONAL EXISTING DIMENSIONS.
FACILITIES

COUCH

CONCRETE PAD
COAT TRANS TRANS
HANGER FORMER FORMER

BARRICADE NOTE:

2024
TRASH PAPER PLASTIC
1125 1125
KVA MDP KVA
REFRIG. MONITOR VENDING

EX
GC MUST PROVIDE, INSTALL AND REMOVE ANY REQUIRED CONSTRUCTION BARRICADE
AT PROJECT WORK AREAS AS REQUIRED PER CODE AND PER MALL MANAGEMENT
NEW REQUIREMENTS.
EXISTING PROCESSING (W) TOILET (M) TOILET EXISTING EXISTING EXSTG. STAFF EX. ELEC. COORDINATE BARRICADE INSTALLATION WITH MALL MANAGEMENT.
MATCHLINE

MATCHLINE

AREA ROOM ROOM LAN ROOM ROOM


AREA 'B'

AREA 'A'

STAFF AREA LOCKER AREA


124 123 122 121 120 120A 119
DOOR NOTE:
G.C. TO INVESTIGATE AND REPAIR
WATER LEAKAGE AT EXISTING
NIGHTBOX (PROCESSING AREA)
EXTERIOR DOOR

T U V SHEET NO:

A-211
U.95

REV. NO:
CONSTRUCTION FLOOR PLAN @ AREA 'B' 1
SCALE: 1/8" = 1'-0"
NORTH REFER TO H&M FURNISHED "IPS DRAWINGS AND
COORDINATE WITH H&M STORE INSTALLATION,
INSTRUCTION & CONSTRUCTION MANUALS.
D.O.B. NO:
COORDINATE WITH FIXTURE VENDOR AND H&M
PROJECT MGR. FOR ADDITIONAL INFORMATION.
SYMBOL DESCRIPTION
LIGHTING & CEILING NOTE: NOTES: NEW ACOUSTIC CEILING TILE AND GRID; REFER TO
GENERAL CONTRACTOR CONFIRM THAT ALL LIGHTING 1. EXISTING LIGHTING, EXIT/EMERGENCY LIGHTS, SPRINKLERS AND FINISH PLAN AND CEILING DETAILS FOR MORE
FIXTURES INDICATED IN EXISTING CEILING AREAS HAVE CEILING RELATED EQUIPMENT TO REMAIN 'AS-IS' UNLESS OTHERWISE INFO.
ALREADY BEEN REPLACED, PER NEW H&M REFRESH
NOTED ON DRAWINGS. (SEE DETAIL -A- THIS DWG.)
STANDARDS. LIGHTING INDICATED IN 'NEW' CEILING
2. NO CHANGE OF EXISTING CEILING HEIGHTS UNLESS NOTED ON
AREAS ARE TO BE NEW OR RELOCATED AS INDICATED GYP. BD. CEILING; REFER TO FINISH PLAN AND
DRAWINGS. CEILING DETAILS FOR MORE INFO.
ON DRAWINGS.
3. G.C. TO FURNISH BLOCKING ABOVE CEILING OR ON WALL, AS REQUIRED, (SEE DETAIL -B- THIS DWG.)
ALL COVE LIGHTING THROUGHOUT TO BE TURNED OFF FOR ALL CEILING / WALL MOUNTED SPECIALTY LIGHTING FIXTURES
AND DISCONNECTED WITHOUT AFFECTING REMAINING CURTAINS AND SIGNS, U.O.N.
LIGHTING. 5. GENERAL CONTRACTOR CLEAN ALL DIFFUSERS AND RELATED HT

G.C. TO COORDINATE WITH H&M CCTV VENDOR FOR


EQUIPMENT THROUGHOUT LEASED AREA AFTER CONSTRUCTION IS
COMPLETED.
FIN
FIN2
CEILING TAG JEFFREY
SECURITY CAMERA AND MONITOR REMOVAL AND
SUPERVISION. PATCH ALL AREAS OF CEILING WHERE
CONSTRUCTION TAG NOTE (SEE DWG.)
TAYLOR
EQUIPMENT HAS BEEN REMOVED. X

EXISTING LIGHTING AND CEILING TO REMAIN 'AS-IS'


ARCHITECT
UNLESS OTHERWISE NOTED ON DRAWING.

572 NORTH BROADWAY


KEY NOTES WHITE PLAINS, NEW YORK 10603

# DESCRIPTION TEL 914 289 0011


J.85 K K.34 K.9 L M N O P 1 EXISTING FITTING ROOM CEILING LIGHT TO BE REMOVED AS REQD.
Q R S
3'-10" 8'-6" 13'-9" 2'-9" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0"
2 EXISTING LIGHTING / ELECTRICAL SERVICE AND ASSOCIATED
EQUIPMENT TO REMAIN U.O.N. REFER TO ELECTRICAL SHTS.
FORMOREN
I FO.
EXISTING NEW OPEN EXISTING EXISTING MEP AND ALL RELATED COMPONENTS TO REMAIN
EXSTG. MENS 3
EXISTING NEW MENS MEN'S EXISTG. MENS LIGHTBOX LIGHTBOX OPEN WINDOW NEW MENS (U.O.N.) . RELOCATE RELATED MEP EQUIPMENT AS REQD.
MEN'S ENTRY OPEN WINDOW SALES AREA OPEN WINDOW WINDOW (WOMENS) WINDOW (KIDS) OPEN WINDOW
113 AND SHOWN ON MEP DRAWINGS. G.C. TO COORDINATE WITH
108 109 101 110 111 112 114
11'-4"AFF ELECTRICAL DRAWINGS, DEMOLITION & REMOVAL GENERAL
11'-4"AFF 11'-4"AFF 11'-4"AFF 11'-4"AFF 11'-4"AFF 11'-4"AFF 11'-4"AFF AND KEY NOTES FOR MORE INFORMATION.
EX. GWB
EX. GWB EX. GWB. EX. GWB. EX. GWB. EX. GWB EX. GWB EX. GWB
PT-1
PT-1 PT-1 PT-1 PT-1 PT-1 PT-1 PT-1 EXISTING CEILING TO REMAIN. G.C. TO REPLACE ANY EXISTING OR
4
NEWLY DAMAGED TILES INCURRED FROM NEW CONSTRUCTION.

5 EXISTING CEILING LIGHTS TO BE REMOVED. CAP WIRES AS REQD.


7 7 7 PATCH AND REPAIR CEILING TO MATCH AND ALIGN WITH EXISTING.
THIS AREA OF CEILING TO BE PATCHED AND REPAIRED TO MATCH AND
6 ALIGN WITH EXISTING. PAINT TO MATCH ADJACENT FINISH.

L L L L L
6A SECTION OF NEW DROPPED GYP. BD. SOFFIT, AT EXISTING DROPPED
22.63 SOFFIT TO ALIGN WITH EDGE OF NEW WALL CONSTRUCTION. SOFFIT TO

MATCHLINE

MATCHLINE
AREA 'B'

AREA 'A'
L L L L L L L MATCH AND ALIGN AND BE PAINTED TO MATCH ADJACENT FINISH.
GC TO FURNISH ATTACHMENT FROM CURTAIN ROD CEILING, AS
LIC # AR0015561
22.48 NEW MENS
OPEN WINDOW 7 REQUIRED, AT CURTAIN LOCATIONS, UNLESS OTHERWISE NOTED. SEE
107 DETAIL 1/A750 FOR ADDITIONAL INFO.
15'-9"

11'-4"AFF LINE OF CURVED METAL DIVIDER PANEL & SUPPORT G.C. TO PROVIDE
22.3 7A
EX. GWB. REQUIRED F.R. BLOCKING ABOVE CEILING AT SUPPORT POINTS - SEE
PT-1 DETAIL 2/A750 FOR ADDTL. INFO.
22.2 2 3 4 L EXISTING INCANDESCENT LIGHT FIXTURES IN NEW CONFIGURED CLICK
L 8 & COLLECT STOCK AREA TO REMAIN AND BE RE-CIRCUITED AS REQD.
M M M PER H&M REQUIREMENTS. SEE ENLARGED MEP PLAN 3/A761 FOR
22 ADDTL. INFO.
M
EXISTING
DISPLAY WINDOW
M
GENERAL CEILING NOTES
106
11'-4"AFF 1. GC TO CLEAN ALL INSTALLED LIGHTING FIXTURES PRIOR TO TURN
EX. GWB. OVER AS REQUIRED. EXP. 2/28/2025
PT-1 2. NO CHANGE IN EXISTING FIRE PROTECTION. ALL FIRE PROTECTION
SPRINKLER HEADS ARE EXISTING TO REMAIN 'AS-IS' (U.O.N.)
REVISION:
25'-0"

3. ALL DIMENSIONS TO BE COORDINATED IN THE FIELD WITH H&M AND


ARE SUBJECT TO EXISTING CONDITIONS DIMENSIONS MARKED AS
NEW WOMENS EQUAL (EQ.) APPLY ONLY WITHIN A GIVEN STRING OF DIMENSIONS
OPEN WINDOW
UNLESS OTHERWISE MARKED.
105 M

11'-4"AFF 4. ALL CONDUITS TO BE CONCEALED UNLESS OTHERWISE NOTED.


EX. GWB. LAYOUT FOR ANY EXPOSED ELECTRICAL CONDUIT TO BE APPROVED
PT-1 BY H&M IN FIELD PRIOR TO INSTALLATION.
6 M 5. REFER TO FINISH FLOOR PLANS FOR FINISH NOTES. GC TO VERIFY ALL
CEILING FINISHES WITH H&M PRIOR TO CONSTRUCTION. ALL CEILING
6A ELEMENTS AND DEVICES (LIGHT FIXTURE HOUSINGS AND TRIMS,
21 M M M M
SPEAKERS, SPRINKLER CAPS, GRILLES, DIFFUSERS, ETC.) SHALL BE
PRE-FINISHED OR BE PAINTED OR COLORED THE SAME COLOR AS THE
ADJACENT CEILING PAINT. ALL PAINTING SHALL BE COMPLETED
N

OFFSITE. GC TO COORDINATE WITH VENDORS AND SUBCONTRACTORS


IG

EXISTING FOR CORRECT FINISHES AND LONG LEAD ITEMS.


AL

WOMENS ENTRY ISSUE DATE:


6. ALL VERTICAL ELEMENTS OF SOFFITS TO BE PAINTED TO MATCH
104
7A 7A 7A ADJACENT COPLANAR WALL PAINT. 06.12.23 FOR REVIEW & APPROVALS
11'-4"AFF 2 3 4
EX. GWB. 7. SPRAY ANY VISIBLE AREA ABOVE GYP. BD. & ACT CEILING BLACK. 07.17.23 FOR BIDS & PERMITS
25'-0"

PT-1 8. GC TO PLUG ALL LIGHT LEAKS IN DISPLAY WALLS / FIXTURES.


9. ALL TRIMLESS LIGHTS TO RECEIVE TEARAWAY BEAD. TRIMLESS LIGHTS
TO HAVE SMOOTH, CLEAN EDGES AND ARE TO BE INSTALLED FLUSH
WITH ADJACENT CEILING.
10. NO
REFER TO LIGHTING FIXTURE SCHEDULE AND NOTES ON ELECTRICAL
USED
DRAWINGS FOR FIXTURE SUPPLY/INSTALLATION RESPONSIBILITIES
AND EMERGENCY LIGHTING LOCATIONS.

20 M M M M M
M ARCH PROJECT NO.: 10835
M
L

12 GA. VERTICAL HANGER


WIRE ANCHORED TO TOP
PRODUCT SEASON: 2024
EXSTG. WOMENS
CHORD OF JOISTS OR
STRUCTURAL STEEL @
SPACE NO.: 185
OPEN WINDOW
L

103
48" O.C. MAX. DRAWN BY: JTA
11'-4"AFF 7A SCALE: AS NOTED
EX. GWB 7A
PT-1 DGLM-26 MAIN TEE
25'-0"

7A SYSTEM WITH CROSS


CHANNEL @ 4'-0" O.C.
SHEET TITLE:

PLASTIC
L

SEE RCP SHEETS

PAPER
U.S. OF GYP. BD. CLG. CEILING PLAN

TRASH
AT AREA - 'A'
5/8" PTD. G.W.B. CEILING

19
EXISTING EXISTING OR NEW WALL.
WOMENS 4 REFER TO CONSTRUCTION
5
SALES AREA FLOOR PLAN

THE MALL AT WELLINGTON GREEN


100

STORE NO. US 326 - RED MOD

BLVD.WELLINGTON, FL. 33414


J.85 K K.34 K.9 L 11'-4"AFF M N O
EX. GWB. GYP. BD. CEILING DETAIL

10300 W. FOREST HILL


PT-1 8 5
SCALE: N.T.S
(TYP. (TYP. 2'-6"
OF 3) OF 5)
P 2 3 4
HATCH INDICATES AREA OF NEW CLICK &
COLLECT STOCK 2 3 4
EXISTING LIGHTING TO REMAIN

2024
127
'AS-IS'. SCHEDULED LED RETROFIT 11'-4"AFF
N.I.C. (UNDER SEPARATE PERMIT) EX. GWB
UNLESS OTHERWISE NOTED. PT-1

18

5 1 6
EXISTING NEW
EXISTING FITTING EXISTING EXISTING PROCESSING

MATCHLINE

MATCHLINE
STOCK RM. STOCK RM. JAN. CL. AREA

AREA 'B'

AREA 'A'
ROOM
126 127 126 125
9'-8" AFF 10'-0"AFF 9'-8" AFF 9'-0"AFF 10'-0" AFF
EX. AC.T. EX. GWB EX. AC.T. EX. ACT EX. AC.T.
PT-1 N/A

EXTERIOR SHEET NO:

Q R S A-310
REV. NO:
CEILING PLAN @ AREA 'A' 1
SCALE: 1/8" = 1'-0"
NORTH

D.O.B. NO:
LIGHTING & CEILING NOTE:
GENERAL CONTRACTOR CONFIRM THAT ALL LIGHTING
NOTES: SYMBOL LEGEND
1. EXISTING LIGHTING, EXIT/EMERGENCY LIGHTS, SPRINKLERS AND
FIXTURES INDICATED IN EXISTING CEILING AREAS HAVE SYMBOL DESCRIPTION
ALREADY BEEN REPLACED, PER NEW H&M REFRESH CEILING RELATED EQUIPMENT TO REMAIN 'AS-IS' UNLESS OTHERWISE
STANDARDS. LIGHTING INDICATED IN 'NEW' CEILING NOTED ON DRAWINGS. NEW ACOUSTIC CEILING TILE AND GRID; REFER TO
AREAS ARE TO BE NEW OR RELOCATED AS INDICATED 2. NO CHANGE OF EXISTING CEILING HEIGHTS UNLESS NOTED ON FINISH PLAN AND CEILING DETAILS FOR MORE
ON DRAWINGS. DRAWINGS. INFO.
3. G.C. TO FURNISH BLOCKING ABOVE CEILING OR ON WALL, AS REQUIRED, (SEE DETAIL -A- THIS DWG.)
ALL COVE LIGHTING THROUGHOUT TO BE TURNED OFF FOR ALL CEILING / WALL MOUNTED SPECIALTY LIGHTING FIXTURES
AND DISCONNECTED WITHOUT AFFECTING REMAINING GYP. BD. CEILING; REFER TO FINISH PLAN AND
CURTAINS AND SIGNS, U.O.N.
LIGHTING. CEILING DETAILS FOR MORE INFO.
5. GENERAL CONTRACTOR CLEAN ALL DIFFUSERS AND RELATED

G.C. TO COORDINATE WITH H&M CCTV VENDOR FOR


EQUIPMENT THROUGHOUT LEASED AREA AFTER CONSTRUCTION IS
COMPLETED.
(SEE DETAIL -B- THIS DWG.)
JEFFREY
SECURITY CAMERA AND MONITOR REMOVAL AND
SUPERVISION. PATCH ALL AREAS OF CEILING WHERE
HT
FIN CEILING TAG
TAYLOR
FIN2
ARCHITECT
X CONSTRUCTION TAG NOTE (SEE DWG.)

EXISTING LIGHTING AND CEILING TO REMAIN 'AS-IS' 572 NORTH BROADWAY


UNLESS OTHERWISE NOTED ON DRAWING.
WHITE PLAINS, NEW YORK 10603

TEL 914 289 0011


KEY NOTES
T U V # DESCRIPTION
25'-0" 25'-0" 23'-6" 1'-6"
1 EXISTING FITTING ROOM CEILING LIGHT TO BE REMOVED AS REQD.

2 EXISTING LIGHTING / ELECTRICAL SERVICE AND ASSOCIATED


EXISTG. KIDS EXISTG. KID'S EQUIPMENT TO REMAIN U.O.N. REFER TO ELECTRICAL SHTS.
SALES AREA OPEN WINDOW FORMOREN
I FO.
102 116
11'-4"AFF 11'-4"AFF EXISTING MEP AND ALL RELATED COMPONENTS TO REMAIN
3
EX. GWB. EX. GWB (U.O.N.) . RELOCATE RELATED MEP EQUIPMENT AS REQD.
AND SHOWN ON MEP DRAWINGS. G.C. TO COORDINATE WITH
PT-1 PT-1
HATCH INDICATES AREA OF ELECTRICAL DRAWINGS, DEMOLITION & REMOVAL GENERAL
AND KEY NOTES FOR MORE INFORMATION.
EXISTING LIGHTING TO REMAIN
'AS-IS'. SCHEDULED LED RETROFIT 4
EXISTING CEILING TO REMAIN. G.C. TO REPLACE ANY EXISTING OR
NEWLY DAMAGED TILES INCURRED FROM NEW CONSTRUCTION.
N.I.C. (UNDER SEPARATE PERMIT)
UNLESS OTHERWISE NOTED. 5 EXISTING CEILING LIGHTS TO BE REMOVED. CAP WIRES AS REQD.
PATCH AND REPAIR CEILING TO MATCH AND ALIGN WITH EXISTING.
THIS AREA OF CEILING TO BE PATCHED AND REPAIRED TO MATCH AND
6

MATCHLINE

MATCHLINE
ALIGN WITH EXISTING. PAINT TO MATCH ADJACENT FINISH.

AREA 'B'

AREA 'A'
SECTION OF NEW DROPPED GYP. BD. SOFFIT, AT EXISTING DROPPED
LIC # AR0015561
6A
SOFFIT TO ALIGN WITH EDGE OF NEW WALL CONSTRUCTION. SOFFIT TO
MATCH AND ALIGN AND BE PAINTED TO MATCH ADJACENT FINISH.
GC TO FURNISH ATTACHMENT FROM CURTAIN ROD CEILING, AS
7 REQUIRED, AT CURTAIN LOCATIONS, UNLESS OTHERWISE NOTED. SEE
DETAIL 1/A750 FOR ADDITIONAL INFO.
22.8 LINE OF CURVED METAL DIVIDER PANEL & SUPPORT G.C. TO PROVIDE
L 7A REQUIRED F.R. BLOCKING ABOVE CEILING AT SUPPORT POINTS - SEE
22.1 DETAIL 2/A750 FOR ADDTL. INFO.
EXISTING INCANDESCENT LIGHT FIXTURES IN NEW CONFIGURED CLICK
8 & COLLECT STOCK AREA TO REMAIN AND BE RE-CIRCUITED AS REQD.
M
PER H&M REQUIREMENTS. SEE ENLARGED MEP PLAN 3/A761 FOR
ADDTL. INFO.

GENERAL CEILING NOTES EXP. 2/28/2025

1. GC TO CLEAN ALL INSTALLED LIGHTING FIXTURES PRIOR TO TURN


OVER AS REQUIRED. REVISION:
2. NO CHANGE IN EXISTING FIRE PROTECTION. ALL FIRE PROTECTION
SPRINKLER HEADS ARE EXISTING TO REMAIN 'AS-IS' (U.O.N.)
M 3. ALL DIMENSIONS TO BE COORDINATED IN THE FIELD WITH H&M AND
ARE SUBJECT TO EXISTING CONDITIONS DIMENSIONS MARKED AS
EQUAL (EQ.) APPLY ONLY WITHIN A GIVEN STRING OF DIMENSIONS
UNLESS OTHERWISE MARKED.
4. ALL CONDUITS TO BE CONCEALED UNLESS OTHERWISE NOTED.
LAYOUT FOR ANY EXPOSED ELECTRICAL CONDUIT TO BE APPROVED
BY H&M IN FIELD PRIOR TO INSTALLATION.
M
M M
5. REFER TO FINISH FLOOR PLANS FOR FINISH NOTES. GC TO VERIFY ALL
CEILING FINISHES WITH H&M PRIOR TO CONSTRUCTION. ALL CEILING
ELEMENTS AND DEVICES (LIGHT FIXTURE HOUSINGS AND TRIMS,
2 3 4 SPEAKERS, SPRINKLER CAPS, GRILLES, DIFFUSERS, ETC.) SHALL BE
PRE-FINISHED OR BE PAINTED OR COLORED THE SAME COLOR AS THE ISSUE DATE:
ADJACENT CEILING PAINT. ALL PAINTING SHALL BE COMPLETED
OFFSITE. GC TO COORDINATE WITH VENDORS AND SUBCONTRACTORS 06.12.23 FOR REVIEW & APPROVALS
FOR CORRECT FINISHES AND LONG LEAD ITEMS. 07.17.23 FOR BIDS & PERMITS
6. ALL VERTICAL ELEMENTS OF SOFFITS TO BE PAINTED TO MATCH
ADJACENT COPLANAR WALL PAINT.

EGRESS CORRIDOR
7. SPRAY ANY VISIBLE AREA ABOVE GYP. BD. & ACT CEILING BLACK.
8. GC TO PLUG ALL LIGHT LEAKS IN DISPLAY WALLS / FIXTURES.
9. ALL TRIMLESS LIGHTS TO RECEIVE TEARAWAY BEAD. TRIMLESS LIGHTS
TO HAVE SMOOTH, CLEAN EDGES AND ARE TO BE INSTALLED FLUSH
WITH ADJACENT CEILING.
10. NO
REFER TO LIGHTING FIXTURE SCHEDULE AND NOTES ON ELECTRICAL
USED
DRAWINGS FOR FIXTURE SUPPLY/INSTALLATION RESPONSIBILITIES
AND EMERGENCY LIGHTING LOCATIONS.
ARCH PROJECT NO.: 10835
PRODUCT SEASON: 2024
SPACE NO.: 185
12 GA. VERTICAL HANGER
WIRE ANCHORED TO TOP
DRAWN BY: JTA
7A CHORD OF JOISTS OR
STRUCTURAL STEEL @
SCALE: AS NOTED
48" O.C. MAX.

SHEET TITLE:
DGLM-26 MAIN TEE
SYSTEM WITH CROSS
CHANNEL @ 4'-0" O.C.
CEILING PLAN
AT AREA - 'B'
MGR./SECR. SEE RCP SHEETS
OFFICE U.S. OF GYP. BD. CLG.
117
9'-0"AFF
5/8" PTD. G.W.B. CEILING
EX. ACT
4 N/A
4

THE MALL AT WELLINGTON GREEN


ADMIN.

STORE NO. US 326 - RED MOD

BLVD.WELLINGTON, FL. 33414


EXISTING OR NEW WALL.
OFFICE REFER TO CONSTRUCTION
118 FLOOR PLAN
2 3 4

10300 W. FOREST HILL


9'-0"AFF
EX. ACT
N/A GYP. BD. CEILING DETAIL
SCALE: N.T.S
5'-2"

6'-87 8"

2024
SINK

4
4 COUCH 4 4

TRASH PAPER PLASTIC

REFRIG. MONITOR VENDING

NEW
PROCESSING (W) TOILET (M) TOILET EXISTING EXISTING EXSTG. STAFF EX. ELEC.
MATCHLINE

MATCHLINE

AREA ROOM ROOM LAN ROOM ROOM


AREA 'B'

AREA 'A'

STAFF AREA LOCKER AREA


124 123 122 121 120 120A 119
10'-0" AFF 9'-0"AFF 9'-0"AFF 9'-0"AFF 9'-0"AFF 9'-0"AFF EXPOSED
EX. AC.T. EX. ACT EX. ACT EX. ACT EX. ACT EX. ACT N/A
N/A N/A N/A N/A N/A NONE

SHEET NO:

T U V A-311
REV. NO:
CEILING PLAN @ AREA 'B' 1
SCALE: 1/8" = 1'-0"
NORTH

D.O.B. NO:
NOTE:
SYMBOL LEGEND
SYMBOL DESCRIPTION
ELEVATION TAG

X
XX DETAIL TAG

X CONSTRUCTION TAG NOTE JEFFREY


J.85 K K.34 K.9 L M N O P Q R S
3'-10" 8'-6" 13'-9" 2'-9" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0"
INDICATES EXISTING PERIMETER FIXTURE /
STANDARD TO REMAIN. SEE FINISH PLAN FOR
TAYLOR
ADDTIONAL INFO.
ARCHITECT
EXISTING NEW OPEN EXISTING
EXSTG. MENS
FIXTURE KEY NOTES
EXISTING NEW MENS MEN'S EXISTG. MENS LIGHTBOX LIGHTBOX OPEN WINDOW NEW MENS
MEN'S ENTRY OPEN WINDOW SALES AREA OPEN WINDOW WINDOW (WOMENS) WINDOW (KIDS)
113
OPEN WINDOW NO DESCRIPTION 572 NORTH BROADWAY
108 109 101 110 4 111 112 114
1 TENANT LEASE LINE. PROJECT TEAM TO VERIFY IN FIELD. WHITE PLAINS, NEW YORK 10603
A600
14'-7"± 23'-1"± 41'-11"±
9'-11 2 NEW STOREFRONT DISPLAY FIXTURE PER H&M STANDARDS
APPROX. LENGTH OF APPROX. LENGTH OF APPROX. LENGTH OF 5 TEL 914 289 0011
3
CURTAIN TRACK CURTAIN TRACK CURTAIN TRACK APPRO "±
A600 OF CU X. LENGTH A600 3 EXISTING EAS STOREFRONT SECURITY PEDESTALS TO REMAIN 'AS-IS'.
1 RTAIN
6 6 2 7 6 9 7 6 TRACK
TYP. 19 NEW H&M STEM MOUNTED, ILLUMINATED LOGO SIGN - CONNECT
2 4
TO EXISTING CIRCUIT. STOREEFRONT SIGNANGE AND GRAPHICS
MUST BE SUBMITTED TO LANDLORD, UNDER SEPARATE COVER, PRIOR
4 TO FABRICATION AND INSTALLATION FOR REVIEW AND APPROVAL.
TYP. L L L L L 14'
22.63 2 APPR -8"± NEW STOREFRONT MANNEQUINS THROUGHOUT PER H&M

MATCHLINE

MATCHLINE
3 OF C OX. LENG 5 STANDARDS

AREA 'B'

AREA 'A'
L L L L L L
14'-0" 4'-9" 4'-9" L URTA
TYP. 1
P6
O
0
-L."'SCHANNEL 6 IN TR TH NEW CEILING MOUNTED SHEER CURTAIN & TRACK. G.C. TO ATTACH
22.48 NEW MENS CURTAIN TRACK CURTAIN TRACK CURTAIN TRACK ACK 6
POS PACKAGE 8'-2 1/2" x 4'-7" 21 TRACK TO GYP, BD. CEILING. SEE SHT A750 & 'H&M' STORE
OPEN WINDOW 21
107 GUIDELINES FOR CONSTRUCTION REQUIREMENTS AND DETAILS.
15'-9"

22.3 6A NEW PERF. METAL DIVIDER CURTAIN & ASSEMBLY. G.C. TO ATTACH
BRACKETS TO GYP. BD. CLG. & FLOOR SEE DET. 6/A702 & 'H&M'
SUPPORT POST TO BE ON BACKSIDE FACING REAR OF STORE. SEE
22.2 1 L STOREGUD
IELN
I ESFORCONSTRUCTO
I NREQURIEMENTSANDDETALIS.
A-702 L
2 6B CEILING MOUNTED CURTAIN RAILINGS - TO EXTEND THE LENGTH OF
M M M
OPEN WINDOW
22 A600 21
7 NEW FREE-STANDING LIGHTBOX INSTALLED PER H&M
EXISTING
M
M
SPECIFICATIONS AND REQUIREMENTS.. PROVIDE NEW OUTLET AT
DISPLAY WINDOW EXISTING CIRCUIT, AS REQD. SEE 'E' DRAWINGS FOR POWER
106 REQUIREMENTS. LIGHTBOXES TO BE PLACED A MIN. OF 2'-0" AWAY
FROM STOREFRONT GLAZING. ALL POWER SOURCES TO BE HIDDEN LIC # AR0015561
FROM VIEW. STOREFRONT LIGHTING & SIGNANGE TO BE ON
21 TENANTS 24/7 - 365 TIME CLOCK PROVIDE ALL SPECIFICATIONS
AND DIMENSIONS.
5
NEW (8) CASHPOINTS (INCLUDING ADA C/W) & (8) BACKWRAPS -
25'-0"

TYP.
8 REUSE EXISTING CONDUITS AND ELECTRICAL FROM PREVIOUS
NEW WOMENS LOCATIONS AND CIRCUIT TO EXISTING SERVICE
OPEN WINDOW
NEW (2) CASHPOINTS (INCLUDING ADA C/W) & (2) BACKWRAPS -
105 M
9 REUSE EXISTING CONDUITS AND ELECTRICAL FROM PREVIOUS
LOCATIONS AND CIRCUIT TO EXISTING SERVICE
21 21 21 21 21 21 NEW RECYCLE CABINET - SEE CONSTRUCTION DRAWINGS FOR
10
ADDTL. INFO.
M
11 NEW 'CLICK & COLLECT' PICK-UP LOCKERS. REFER TO 'H&M' STORE
GUIDELINES FOR CONSTRUCTION REQUIREMENTS AND DETAILS.
21 M M M M
EXISTING VENDING MACHINE REMOVAL / REPLACEMENT TO BE EXP. 2/28/2025
12 COORDINATED WITH H&M STORE TEAM.
13 NEW PROCESSING AREA EQUIPMENT, AS REQD., PER H&M STANDARDS.
METAL DIVIDER CURTAIN

METAL DIVIDER CURTAIN


21 21 21 21 REVISION:
EXISTING HANGER SYSTEM TO BE RELOCATED AS SHOWN. VERIFY &

MTL. DIVIDER CURTAIN


EXISTING 21 13A
WOMENS ENTRY COORDINATE IN FIELD WITH H&M PROJECT MANAGER
NEW ADJUSTABLE HEIGHT PROCESSING TABLE, PROVIDE ELECTRIC
11'-3 21"

11'-3 21"
104 6 14
SERVICES AS REQD.

9'-9"
A702
15 EXISTING .NIGHT BOX' DOOR TO BE MODIFIED AS REQD. FOR EXIT USE
TYP. ONLY. ALL EXTERIOR ENTRY HARDWARE TO BE REMOVED AND SIGN
25'-0"

4 APPLIED TO DOOR 'FOR EXIT ONLY'


TYP. NEW LOW PARTITION AT EXPANDED FITTING ROOM SERVICE AREA,
16 SEE CONSTRUCTION PLAN FOR ADDTL. INFO. - COORDINATE
1 3 6A 6A 6A CONSTRUCTION WITH H&M PROJECT MANAGER
TYP. EXISTING FITTING ROOM ENCLOSURES TO REMAIN 'AS-IS'. NEW
A600
17 FITTING ROOM FIXTURES, SUPPLIED BY H&M AND INSTALLED BY G.C.
PER H&M HOW TO BUILD CONSTRUCTION MANUAL AND
REQUIREMENTS. SEE MEP DRAWINGS FOR POWER REQUIREMENTS.
PORTION OF EXISTING SALES AREA CONVERTED TO NEW 'CLICK &
18 COLLECT' STORAGE ROOM WITH NEW DOOR AND HARDWARE AS ISSUE DATE:
20 6 M M M M M M
M
REQD. REFER TO ELECTRICAL SHTS. FOR ELEC. REQUIRMENTS.
LOCATION OF NEW POSTER CHANNELS INSTALLED PER LATEST 06.12.23 FOR REVIEW & APPROVALS
L
K
RAC

19 'STORE GUIDELINES' INSTRUCTIONS. COORDINATE LOCATION WITH


H&M PROJECT MANGER 07.17.23 FOR BIDS & PERMITS
NT

EXSTG. WOMENS
I
RTA

OPEN WINDOW
L

EXISTING 'H&M' RECESSED ILLUMINATED LOGO SIGN TO REMAIN -


OF "±

103
CU

10 11 20 G.C. TO CHECK FOR PROPER OPERATION AND REPORT TO H&M


-9

1
24'

6A 6A A-741 PROJECT MANGER OD ANY DARK SPOTTING IS PRESENT AND IF


SIGN LIGHTING NEEDS REPAIR.
TH

METAL DIVIDER CURTAIN

METAL DIVIDER CURTAIN


LEN

2
25'-0"

5G 21 EXISTING PERIMETER WALL MOUNTED FIXTURES TO REMAIN.


RX.

PLASTIC
A702

CURTAIN TRACK
APP

11'-3 21"

11'-3 21"
L

6 6 6

PAPER
6A A702 A702 A702 22 EXISTING RECESSED WALL STANDARDS TO REMAIN TO REMAIN.

11'-3 21"

TRASH
4F
1 6A A702 23 NEW BREAK ROOM TABLE, SUPPLIED AND INSTALLED BY G.C. PER ARCH PROJECT NO.: 10835
A-730 SPECS. SEE FURNITURE LEGEND FOR ADDTL. INFO.
21 21
1 6
21 24 NEW BREAK ROOM CHAIRS, SUPPLIED AND INSTALLED BY G.C. PER PRODUCT SEASON: 2024
SPECS. SEE FURNITURE LEGEND FOR ADDTL. INFO.

4'-0" X 7'-0"
6
NEW DIRECT REPLACEMENT HI - LO DRINKING FOUNTAIN:'ELKAY'. SPACE NO.: 185
25 MOD. NO. LZSTL8WSSP, HI-LO DRINKING FOUNTAIN & BOTTLE DRAWN BY: JTA
19
MILLWORK
FILLING STATION.
19 CHANNEL LENGTH 28'-10 1/2" 16 DECO TABLE
SCALE: AS NOTED

SERVICE
EXISTING

SINK
18 HW
WOMENS
SALES AREA
POS PACKAGE 24'-7"x 4'-7" 3'-0" X 7'-0"
FIXTURE PLAN NOTES
100 3'-4" X 7'-0" 3'-8" X 7'-0"

J.85 K K.34 K.9 L M N O 1. THIS PLAN IS FOR INFORMATIONAL PURPOSES ONLY. ALL FIXTURES SHEET TITLE:
19 WILL BE SUPPLIED BY H&M AND INSTALLED BY GENERAL
CHANNEL LENGTH 5'-3" CONTRACTOR. G.C. TO COORDINATE LOCATION OF REQUIRED FIXTURE PLAN
POS PACKAGE 4'-11"x 2'-7" BLOCKING FOR HOOKS, WALL FIXTURES, ETC. WITH OWNER
3
A-761
2
A-702 2'-6" PROVIDED FIXTURE/MILLWORK SHOP DRAWINGS. ALL BLOCKING
AT AREA 'A'
P 17 TO BE FRT. MAINTAIN A MIN OF 36" AROUND FLOOR FIXTURES AND

SAMPLE WALL
8 MANNEQUIN /
NEW CLICK & PROP STORAGE 44" AT PERIMETER/FLOOR FIXTURES DURING FINAL INSTALL.
COLLECT STOCK COORDINATE EXACT FIXTURES AND LOCATIONS WITH H&M FIELD
127 REP. REFER TO H&M PROVIDED H&M'S PROVIDED "IPS DRAWINGS,
CURTAIN RAILING GENERAL FIXTURE NOTES: NEW CLICK & CATALOGUES, AND CONSTRUCTION INFORMATION" FOR FIXTURE

FACILITIES
G.C. TO INSTALL BLOCKING BEHIND WALLS AT COLLECT STORAGE TYPES AND MORE INFORMATION.
L L AREA FIXTURE
L L PERIMETER FIXTURING WHERE REQUIRED AND
PACKAGE PER H&M 2. VERIFY ALL DIMENSIONS OF MILLWORK, FIXTURES, AND FITTING
L L ABOVE CEILING WHERE FIXTURE POST EXTEND

THE MALL AT WELLINGTON GREEN


STANDARDS 1 VISUAL ROOM FIXTURES AND DOORS WITH H&M PRIOR TO LAYOUT.
L L TO CEILING. CHECK-IN

STORE NO. US 326 - RED MOD


A-730

BLVD.WELLINGTON, FL. 33414


L L 18
L L 3. G.C. IS RESPONSIBLE FOR COORDINATING, RECEIVING, AND
L L G.C. TO PURCHASE AND INSTALL 1/2" DIA. UNLOADING ALL H&M SUPPLIED FIXTURES. G.C. TO TAKE
L L PEA-GRAVEL BASE AND 1/2" RUBBER MULCH

10300 W. FOREST HILL


INVENTORY OF SHIPMENT & REPORT ANY DISCREPANCY &
(BROWN) FOR FILLING OF PLANTER POTS EXISTING NEW MISSING, DAMAGE ITEM WITH IN 48 HOUR OF DELIVERY,
(MULCH TO 2" FROM TOP OF PLANTER POTS), EXISTING FITTING EXISTING EXISTING PROCESSING OTHERWISE G.C. WILL BE CHARGED FOR MISSING DAMAGED ITEMS.

MATCHLINE

MATCHLINE
THROUGHOUT STORE. STOCK RM. ROOM STOCK RM. JAN. CL. AREA

AREA 'B'

AREA 'A'
126 127 126 125 4. G.C. IS RESPONSIBLE FOR DISPOSAL OF ALL ASSOCIATED
NEW FITTING NO CHANGE NEW WRAPPING, CRATING AND REFUSE FROM H&M FIXTURES.

2024
ROOM INTERIOR PROCESSING
PACKAGE PER H&M AREA EQUIPMENT 5. ALL WORK TO COMPLY WITH ALL APPLICABLE LOCAL, STATE, AND
STANDARDS AND FURNITURE FEDERAL BY-LAWS AND CODE REQUIREMENTS.
EXTERIOR PER H&M
6. G.C. IS RESPONSIBLE FOR PROVIDING ALL BRACING/BLOCKING
STANDARDS
REQUIRED BY CODE AND STRUCTURAL NECESSITY FOR ALL FIXTURES
AFFIXED TO WALLS AND CEILINGS. G.C. TO COORDINATE WITH
H&M.
7. G.C. TO COORDINATE ELECTRICAL REQUIREMENTS OF MILLWORK
Q R S FIXTURES. COORDINATE FIXTURE LAYOUT WITH MEP. ANY FLOOR
MOUNTED ELEC. BOX TO BE FLUSH MOUNTED.
FIXTURE PLAN @ AREA 'A' 1 8. NOT USED.
SCALE: 1/8" = 1'-0"
9. G.C. TO PROVIDE ELECTRICAL POWER AND FINAL HOOK-UPS FOR
ALL STORE FIXTURES WHICH CONTAIN ELECTRICAL
ELEMENTS/LIGHTING. G.C. TO COORDINATE W/SHOP DRAWINGS
TO BE PROVIDED BY OWNER. THE FIXTURE CONTRACTOR IS
PLAN CORNER GUARD LEGEND GENERAL NOTE FIXTURE MIRROR GENERAL NOTE RESPONSIBLE FOR ALL U.L. LISTING OF ALL FIXTURES REQUIRING SHEET NO:
ELECTRICAL. SEE FIXTURE AND ELECTRICAL DRAWINGS FOR MORE

A-410
1. ALL MIRRORS ARE SUPPLIED AND INSTALLED BY G.C. FITTING
NORTH SYMBOL DESCRIPTION 1. REFER TO H&M INTERIOR CATALOGUE AN STORE HOW TO ROOM CABIN MIRRORS WITH RADIAL TOPS TO BE CUT BY LOCAL
INFORMATION.
BUILD FOR SALES AREA FIXTURES ASSEMBLED BY G.C. GLAZER. 10. FITTING ROOM CURTAINS AND CURTAIN RODS FURNISHED BY
G.C. TO REMOVE ALL CORNER GUARDS AND ADD
2. BOH FURNITURE TO BE ASSEMBLED & INSTALLED BY G.C. TENANT AND INSTALLED BY G.C. G.C. TO PROVIDE FRT. BLOCKING
NEW CORNER GUARDS THROUGHOUT SALES AREA 2. FIXTURE MIRROR LOCATION SHOWN ARE NOT NECESSARILY AS REQUIRED. REFER TO SHEETS A-730 AND H&M'S PROVIDED "IPS
WITH COLOR TO MATCH ADJACENT WALL FIINISH - INDICATIVE OF FINAL LOCATIONS.
3. G.C. TO PROVIDE AND INSTALL 6" FLAT METAL PLATE CORNER DRAWINGS, CATALOGUES, AND CONSTRUCTION INFORMATION"
SEE FINISH PLAN FOR ADDITIONAL CORNER GUARD
BRACE AT THE UNDERSIDE OF EACH CORNER OR EQUALLY FOR FIXTURE TYPES AND MORE INFORMATION.
INFORMATION AND COORDINATED COLORS. 3. G.C. SHALL COORDINATE WITH H&M REP. PRIOR TO INSTALLATION
AROUND CIRCUMFERENCE OF ALL RUGS. ATTACH WITH HEAVY OF COLUMN MIRRORS, IF REQD. REV. NO:
DUTY DUCT TAPE. 11. G.C. SHALL INSTALL FLOOR FIXTURES AND CASHWRAP PER
CURTAIN TRACK & CURTAIN NOTES 4. ALL FREE-STANDING SALES AREA, NON-MOBILE FIXTURES OVER
4. COORDINATE LOCATION OF FIRE ALARM HORNS, STROBES, PULL
DRAWINGS. COORDINATE FINAL FLOOR FIXTURE PLACEMENT WITH
H&M REP AND LOCAL CODES. EGRESS PATH MUST BE MAINTAINED.
STATIONS, ETC. MIRROR LOCATIONS SHOULD BE TAKEN INTO
5'-9" TALL TO BE FIXED TO FLOOR. NOT INCLUDING CONSIDERATION BEFORE MOUNTING DEVICES. COORDINATE
· G.C. TO FURNISH AND INSTALL ALL SCREWS AND FIXINGS REQUIRED TO INSTALL FREESTANDING MIRRORS, FREESTANDING STORE GUIDES AND 12. G.C. TO FURNISH AND INSTALL FELT FABRIC TO UNDERSIDE OF
CURTAIN TRACK, TYP. SEE 1/A750 FOR ADDTL. INFO. FINAL LOCATIONS WITH H&M ON-SITE PROJECT MANAGER. FREESTANDING LIGHTBOX STAND.
A-AREA BACKDROPS
13. FLAME SPREAD AND SMOKE DEVELOPMENT RATING FOR ALL FINISH
REFER TO H&M FURNISHED "IPS DRAWINGS AND · G.C. TO ATTACHED METAL TUBING HOLDING CURTAIN ROD TO DECK /
STRUCTURE ABOVE. TUBES CANNOT BE ATTACHED / SUPPORTED TO CEILING.
5. CURTAINS SHOULD BE HEMMED TO 50MM // 2 INCHES ABOVE
MATERIALS TO COMPLY WITH INTERNATIONAL BUILDING CODE AND
FINISH FLOOR. ALL CEILING HEIGHTS + CURTAIN LENGTHS
COORDINATE WITH H&M STORE INSTALLATION, · G.C. TO CUT CURTAIN TRACKS ON-SITE, AS REQUIRED.
SHOULD BE VERIFIED PRIOR. AFTER COMPLETION + ONCE HUNG
ALL APPLICABLE CODES D.O.B. NO:
ON THE TRACK, CURTAINS SHOULD BE TIED UP OFF OF THE
INSTRUCTION & CONSTRUCTION MANUALS. FLOOR SO THAT THEY DO NOT GET DIRTY OR DAMAGED PRIOR
· BOTTOM OF CURTAINS TO BE HEMMED TO SIT 2" ABOVE FINISHED FLOOR, BY
COORDINATE WITH FIXTURE VENDOR AND H&M G.C., TYP. TO TURNOVER OF THE SPACE.

PROJECT MGR. FOR ADDITIONAL INFORMATION. · FACE OF CURTAIN TRACK TO FACE TOWARD OUTSIDE OF FITTING ROOM 6. PLANT POT PINE BARK OR EQUIVALENT BY G.C.
CUBICLE.
NOTE:
CORNER GUARD LEGEND GENERAL NOTE
SYMBOL DESCRIPTION
SYMBOL LEGEND
1. REFER TO H&M INTERIOR CATALOGUE AN STORE HOW TO SYMBOL DESCRIPTION
G.C. TO REMOVE ALL CORNER GUARDS AND ADD BUILD FOR SALES AREA FIXTURES ASSEMBLED BY G.C.
NEW CORNER GUARDS THROUGHOUT SALES AREA ELEVATION TAG
2. BOH FURNITURE TO BE ASSEMBLED & INSTALLED BY G.C.
WITH COLOR TO MATCH ADJACENT WALL FIINISH -
SEE FINISH PLAN FOR ADDITIONAL CORNER GUARD 3. G.C. TO PROVIDE AND INSTALL 6" FLAT METAL PLATE CORNER
INFORMATION AND COORDINATED COLORS. BRACE AT THE UNDERSIDE OF EACH CORNER OR EQUALLY X
AROUND CIRCUMFERENCE OF ALL RUGS. ATTACH WITH HEAVY XX DETAIL TAG
CURTAIN TRACK & CURTAIN NOTES DUTY DUCT TAPE.
X CONSTRUCTION TAG NOTE
JEFFREY
4. ALL FREE-STANDING SALES AREA, NON-MOBILE FIXTURES OVER
· G.C. TO FURNISH AND INSTALL ALL SCREWS AND FIXINGS REQUIRED TO INSTALL
CURTAIN TRACK, TYP. SEE 1/A750 FOR ADDTL. INFO.
5'-9" TALL TO BE FIXED TO FLOOR. NOT INCLUDING
FREESTANDING MIRRORS, FREESTANDING STORE GUIDES AND INDICATES EXISTING PERIMETER FIXTURE /
TAYLOR
A-AREA BACKDROPS STANDARD TO REMAIN. SEE FINISH PLAN FOR
T U V · G.C. TO ATTACHED METAL TUBING HOLDING CURTAIN ROD TO DECK / ADDTIONAL INFO. ARCHITECT
STRUCTURE ABOVE. TUBES CANNOT BE ATTACHED / SUPPORTED TO CEILING. 5. CURTAINS SHOULD BE HEMMED TO 50MM // 2 INCHES ABOVE
25'-0" 25'-0" 23'-6" 1'-6"
· G.C. TO CUT CURTAIN TRACKS ON-SITE, AS REQUIRED.
FINISH FLOOR. ALL CEILING HEIGHTS + CURTAIN LENGTHS
SHOULD BE VERIFIED PRIOR. AFTER COMPLETION + ONCE HUNG
FIXTURE KEY NOTES
ON THE TRACK, CURTAINS SHOULD BE TIED UP OFF OF THE NO DESCRIPTION 572 NORTH BROADWAY
· BOTTOM OF CURTAINS TO BE HEMMED TO SIT 2" ABOVE FINISHED FLOOR, BY FLOOR SO THAT THEY DO NOT GET DIRTY OR DAMAGED PRIOR
G.C., TYP. TO TURNOVER OF THE SPACE. 1 TENANT LEASE LINE. PROJECT TEAM TO VERIFY IN FIELD.
WHITE PLAINS, NEW YORK 10603
EXISTG. KIDS EXISTG. KID'S
SALES AREA OPEN WINDOW · FACE OF CURTAIN TRACK TO FACE TOWARD OUTSIDE OF FITTING ROOM 6. PLANT POT PINE BARK OR EQUIVALENT BY G.C.
102 116 CUBICLE. 2 NEW STOREFRONT DISPLAY FIXTURE PER H&M STANDARDS TEL 914 289 0011
3 EXISTING EAS STOREFRONT SECURITY PEDESTALS TO REMAIN 'AS-IS'.

NEW H&M STEM MOUNTED, ILLUMINATED LOGO SIGN - CONNECT


4
IKEA FURNITURE SCHEDULE FOR B.O.H.
(IKEA: FURNISHED AND INSTALLED BY G.C.)
TO EXISTING CIRCUIT. STOREEFRONT SIGNANGE AND GRAPHICS
MUST BE SUBMITTED TO LANDLORD, UNDER SEPARATE COVER, PRIOR
TO FABRICATION AND INSTALLATION FOR REVIEW AND APPROVAL.
NO. DESCRIPTION MANUF. MODEL LOCATION # NEW STOREFRONT MANNEQUINS THROUGHOUT PER H&M
TABLE EKEDALEN
5 STANDARDS
6
A600
AA (31.5" x 48"- 71") NOT USED
IKEA
703.408.07
SEE PLANS X
6 NEW CEILING MOUNTED SHEER CURTAIN & TRACK. G.C. TO ATTACH
APPR TRACK TO GYP, BD. CEILING. SEE SHT A750 & 'H&M' STORE

MATCHLINE

MATCHLINE
OF C OX. LENG TABLE EKEDALEN
NOT USED

AREA 'B'

AREA 'A'
URTA BB IKEA SEE PLANS X GUIDELINES FOR CONSTRUCTION REQUIREMENTS AND DETAILS.
IN TR TH (36" x 71"- 95") 703.407.65
ACK 1
TABLE LINNMON+GODVIN 6A NEW PERF. METAL DIVIDER CURTAIN & ASSEMBLY. G.C. TO ATTACH
CC IKEA SEE PLANS 2 BRACKETS TO GYP. BD. CLG. & FLOOR SEE DET. 6/A702 & 'H&M'
( 24" X 48") 603.537.58
20 2 SUPPORT POST TO BE ON BACKSIDE FACING REAR OF STORE. SEE
LANGFJALL STOREGUD
IELN
I ESFORCONSTRUCTO
I NREQURIEMENTSANDDETALIS.
DD TASK CHAIR NOT USED
IKEA
292.809.10
SEE PLANS X
MALL 6B CEILING MOUNTED CURTAIN RAILINGS - TO EXTEND THE LENGTH OF
(2)3'-0" X 7'-0"
H.M. DOOR JANINGE OPEN WINDOW
22.8 EE LOUNGE CHAIR IKEA
002.460.78
SEE PLANS 8
L 7 NEW FREE-STANDING LIGHTBOX INSTALLED PER H&M
21 21 22.1 SPECIFICATIONS AND REQUIREMENTS.. PROVIDE NEW OUTLET AT
EXISTING CIRCUIT, AS REQD. SEE 'E' DRAWINGS FOR POWER
REQUIREMENTS. LIGHTBOXES TO BE PLACED A MIN. OF 2'-0" AWAY
LIC # AR0015561
M FIRE BLANKET (FB1) FROM STOREFRONT GLAZING. ALL POWER SOURCES TO BE HIDDEN
FROM VIEW. STOREFRONT LIGHTING & SIGNANGE TO BE ON
G.C TO PROVIDE "MART COBRA" FIRE BLANKET (OR APPROVED EQUAL). TENANTS 24/7 - 365 TIME CLOCK PROVIDE ALL SPECIFICATIONS
FIRE BLANKET TO BE MOUNTED ON HANGERS OR BRACKETS WITHIN CABINETS (NOTE: AND DIMENSIONS.
TOP OF BLANKET TO BE NO MORE THAN +48" A.F.F) . INSTALL PER STATE AND NEW (8) CASHPOINTS (INCLUDING ADA C/W) & (8) BACKWRAPS -
FEDERAL ACCESSIBILITY REQUIREMENTS.
8 REUSE EXISTING CONDUITS AND ELECTRICAL FROM PREVIOUS
22 LOCATIONS AND CIRCUIT TO EXISTING SERVICE
G.C TO PROVIDE SIGN AT FIRE EXTINGUISHER - FOR FIRE BLANKET LOCATION.
CONFIRM FINAL LOCATION WITH H&M P.M NEW (2) CASHPOINTS (INCLUDING ADA C/W) & (2) BACKWRAPS -
9 REUSE EXISTING CONDUITS AND ELECTRICAL FROM PREVIOUS
LOCATIONS AND CIRCUIT TO EXISTING SERVICE
M
FIRE EXTINGUISHER (FE1) 10 NEW RECYCLE CABINET - SEE CONSTRUCTION DRAWINGS FOR
ADDTL. INFO.
F.E.1 DENOTES 10 LBS. ABC 10-W. UNIT MOUNTED TO WALL W/ HANGER (NO NEW 'CLICK & COLLECT' PICK-UP LOCKERS. REFER TO 'H&M' STORE
CABINET). LOCATION OF FIRE EXTINGUISHERS ON PLAN ARE TENANT'S MINIMUM 11
GUIDELINES FOR CONSTRUCTION REQUIREMENTS AND DETAILS.
REQUIREMENTS. G.C. TO FURNISH & INSTALL AND SHALL COORDINATE WITH TENANT'S
EXISTING VENDING MACHINE REMOVAL / REPLACEMENT TO BE EXP. 2/28/2025
21 REPRESENTATIVE AND LOCAL FIRE MARSHAL FOR ADDITIONAL REQUIRED LOCATIONS. 12 COORDINATED WITH H&M STORE TEAM.
13 NEW PROCESSING AREA EQUIPMENT, AS REQD., PER H&M STANDARDS.
M M M
REVISION:
EXISTING HANGER SYSTEM TO BE RELOCATED AS SHOWN. VERIFY &
13A
21 COORDINATE IN FIELD WITH H&M PROJECT MANAGER
NEW ADJUSTABLE HEIGHT PROCESSING TABLE, PROVIDE ELECTRIC
14
SERVICES AS REQD.
15 EXISTING .NIGHT BOX' DOOR TO BE MODIFIED AS REQD. FOR EXIT USE
ONLY. ALL EXTERIOR ENTRY HARDWARE TO BE REMOVED AND SIGN
APPLIED TO DOOR 'FOR EXIT ONLY'
21 NEW LOW PARTITION AT EXPANDED FITTING ROOM SERVICE AREA,
16 SEE CONSTRUCTION PLAN FOR ADDTL. INFO. - COORDINATE
CONSTRUCTION WITH H&M PROJECT MANAGER

EGRESS CORRIDOR
EXISTING FITTING ROOM ENCLOSURES TO REMAIN 'AS-IS'. NEW
17 FITTING ROOM FIXTURES, SUPPLIED BY H&M AND INSTALLED BY G.C.
PER H&M HOW TO BUILD CONSTRUCTION MANUAL AND
REQUIREMENTS. SEE MEP DRAWINGS FOR POWER REQUIREMENTS.
PORTION OF EXISTING SALES AREA CONVERTED TO NEW 'CLICK &
18 COLLECT' STORAGE ROOM WITH NEW DOOR AND HARDWARE AS ISSUE DATE:
REQD. REFER TO ELECTRICAL SHTS. FOR ELEC. REQUIRMENTS. 06.12.23 FOR REVIEW & APPROVALS
LOCATION OF NEW POSTER CHANNELS INSTALLED PER LATEST
19 'STORE GUIDELINES' INSTRUCTIONS. COORDINATE LOCATION WITH 07.17.23 FOR BIDS & PERMITS
22 H&M PROJECT MANGER

EXISTING 'H&M' RECESSED ILLUMINATED LOGO SIGN TO REMAIN -


20 G.C. TO CHECK FOR PROPER OPERATION AND REPORT TO H&M
PROJECT MANGER OD ANY DARK SPOTTING IS PRESENT AND IF
SIGN LIGHTING NEEDS REPAIR.

21 EXISTING PERIMETER WALL MOUNTED FIXTURES TO REMAIN.

22 EXISTING RECESSED WALL STANDARDS TO REMAIN TO REMAIN.


21
23 NEW BREAK ROOM TABLE, SUPPLIED AND INSTALLED BY G.C. PER ARCH PROJECT NO.: 10835
21 22 21 SPECS. SEE FURNITURE LEGEND FOR ADDTL. INFO.
NEW BREAK ROOM CHAIRS, SUPPLIED AND INSTALLED BY G.C. PER PRODUCT SEASON: 2024
24
SPECS. SEE FURNITURE LEGEND FOR ADDTL. INFO. SPACE NO.: 185
MGR./SECR. NEW DIRECT REPLACEMENT HI - LO DRINKING FOUNTAIN:'ELKAY'.
OFFICE 25 MOD. NO. LZSTL8WSSP, HI-LO DRINKING FOUNTAIN & BOTTLE DRAWN BY: JTA
117 FILLING STATION. SCALE: AS NOTED
4'-0" X 7'-0"

SAFE

NO CHANGE
LAN
RACK FIXTURE PLAN NOTES
SHEET TITLE:
3'-0" X 7'-0"

1. THIS PLAN IS FOR INFORMATIONAL PURPOSES ONLY. ALL FIXTURES


3'-0" X 7'-0"

3'-0" X 7'-0"
WILL BE SUPPLIED BY H&M AND INSTALLED BY GENERAL
CONTRACTOR. G.C. TO COORDINATE LOCATION OF REQUIRED
FIXTURE PLAN
3'-8" X 7'-0"
ADMIN.
HI-LO
DRINKING
FOUNTAIN
OFFICE BLOCKING FOR HOOKS, WALL FIXTURES, ETC. WITH OWNER AT AREA 'B'
118 PROVIDED FIXTURE/MILLWORK SHOP DRAWINGS. ALL BLOCKING
13A
25 NO CHANGE TO BE FRT. MAINTAIN A MIN OF 36" AROUND FLOOR FIXTURES AND
TIME 44" AT PERIMETER/FLOOR FIXTURES DURING FINAL INSTALL.
CLOCK
COORDINATE EXACT FIXTURES AND LOCATIONS WITH H&M FIELD
(x8) REP. REFER TO H&M PROVIDED H&M'S PROVIDED "IPS DRAWINGS,
MANNEQUIN / EE T-WAVE T-WAVE
23 12 CATALOGUES, AND CONSTRUCTION INFORMATION" FOR FIXTURE
LOCKERS

PROP STORAGE
5'-2"

6'-87 8" TYPES AND MORE INFORMATION.


PROCESSING AREA

14 24
LOCKERS
SINK

SUSP.
2. VERIFY ALL DIMENSIONS OF MILLWORK, FIXTURES, AND FITTING

THE MALL AT WELLINGTON GREEN


X-MER

CC CC COUCH
ROOM FIXTURES AND DOORS WITH H&M PRIOR TO LAYOUT.

STORE NO. US 326 - RED MOD

BLVD.WELLINGTON, FL. 33414


13 10
COAT CONCRETE PAD 3. G.C. IS RESPONSIBLE FOR COORDINATING, RECEIVING, AND
TRANS TRANS
FE1 HANGER UNLOADING ALL H&M SUPPLIED FIXTURES. G.C. TO TAKE

10300 W. FOREST HILL


FORMER FORMER
TRASH PAPER PLASTIC
FB1 1125 1125
INVENTORY OF SHIPMENT & REPORT ANY DISCREPANCY &
KVA KVA
REFRIG. MDP
MONITOR VENDING

MISSING, DAMAGE ITEM WITH IN 48 HOUR OF DELIVERY,


OTHERWISE G.C. WILL BE CHARGED FOR MISSING DAMAGED ITEMS.
15 1
A-741 4. G.C. IS RESPONSIBLE FOR DISPOSAL OF ALL ASSOCIATED
NEW
PROCESSING (W) TOILET (M) TOILET EXISTING EXISTING EXSTG. STAFF1 EX. ELEC. WRAPPING, CRATING AND REFUSE FROM H&M FIXTURES.

2024
MATCHLINE

MATCHLINE

AREA ROOM ROOM LAN ROOM STAFF AREA LOCKER AREA ROOM
AREA 'B'

AREA 'A'

124 123 122 121 120 120A 119 5. ALL WORK TO COMPLY WITH ALL APPLICABLE LOCAL, STATE, AND
NO CHANGE NO CHANGE NO CHANGE · NEW RECYCLE NO CHANGE NO CHANGE FEDERAL BY-LAWS AND CODE REQUIREMENTS.
NEW
PROCESSING STATION.
6. G.C. IS RESPONSIBLE FOR PROVIDING ALL BRACING/BLOCKING
AREA EQUIPMENT · VENDING
REQUIRED BY CODE AND STRUCTURAL NECESSITY FOR ALL FIXTURES
AND FURNITURE MACHINE
AFFIXED TO WALLS AND CEILINGS. G.C. TO COORDINATE WITH
PER H&M REMOVED
H&M.
STANDARDS
7. G.C. TO COORDINATE ELECTRICAL REQUIREMENTS OF MILLWORK
FIXTURES. COORDINATE FIXTURE LAYOUT WITH MEP. ANY FLOOR
MOUNTED ELEC. BOX TO BE FLUSH MOUNTED.
T U V 8. NOT USED.
U.95 9. G.C. TO PROVIDE ELECTRICAL POWER AND FINAL HOOK-UPS FOR
ALL STORE FIXTURES WHICH CONTAIN ELECTRICAL
ELEMENTS/LIGHTING. G.C. TO COORDINATE W/SHOP DRAWINGS
FIXTURE PLAN @ AREA 'B' 1 TO BE PROVIDED BY OWNER. THE FIXTURE CONTRACTOR IS
RESPONSIBLE FOR ALL U.L. LISTING OF ALL FIXTURES REQUIRING SHEET NO:

A-411
SCALE: 1/8" = 1'-0" ELECTRICAL. SEE FIXTURE AND ELECTRICAL DRAWINGS FOR MORE
NORTH INFORMATION.
10. FITTING ROOM CURTAINS AND CURTAIN RODS FURNISHED BY
TENANT AND INSTALLED BY G.C. G.C. TO PROVIDE FRT. BLOCKING
AS REQUIRED. REFER TO SHEETS A-730 AND H&M'S PROVIDED "IPS
DRAWINGS, CATALOGUES, AND CONSTRUCTION INFORMATION"
FOR FIXTURE TYPES AND MORE INFORMATION.
REV. NO:
11. G.C. SHALL INSTALL FLOOR FIXTURES AND CASHWRAP PER
DRAWINGS. COORDINATE FINAL FLOOR FIXTURE PLACEMENT WITH
H&M REP AND LOCAL CODES. EGRESS PATH MUST BE MAINTAINED.
12. G.C. TO FURNISH AND INSTALL FELT FABRIC TO UNDERSIDE OF
FREESTANDING LIGHTBOX STAND.
REFER TO H&M FURNISHED "IPS DRAWINGS AND 13. FLAME SPREAD AND SMOKE DEVELOPMENT RATING FOR ALL FINISH
MATERIALS TO COMPLY WITH INTERNATIONAL BUILDING CODE AND
COORDINATE WITH H&M STORE INSTALLATION, ALL APPLICABLE CODES D.O.B. NO:
INSTRUCTION & CONSTRUCTION MANUALS.
COORDINATE WITH FIXTURE VENDOR AND H&M
PROJECT MGR. FOR ADDITIONAL INFORMATION.
SEE DRAWING A-511 FOR KEY NOTES NOTE:
ADDITIONAL FINISH PLAN # DESCRIPTION REFER TO SHT. A-511 FOR FINISH KEY AND GENERAL NOTES.

INFORMATION AND NOTES 1 EXISTING FLOORING TO REMAIN, CLEAN & POLISH AS NEEDED. LEGEND
PAINTED NAVIGATION APPLIED TO WALLS. COORDINATE SPEC. WITH LATEST SYMBOL DESCRIPTION
2 IPS AND INSTALLATION WITH CURRENT STORE INSTRUCTIONS. COORDINATE
INSTALLATION WITH H&M P.M . NOTE: WALLS TO BE PAINTED PRIOR TO XX-X FINISH TAG - SEE DWG. A-511 JEFFREY
APPLICATION. (SEE FINISH "PT-G")

3 EXISTING FITTING ROOM CABINS, CURTAIN ROD & CURTAINS TO REMAIN. XX-X EXTENT OF PAINTED AND/OR WALL FINISH.
TAYLOR
NEW PRE-FAB FITTING ROOM PARTITIONS PROVIDED BY H&M AND INSTALL BY
NOT USED X KEY NOTE - SEE THIS DRAWING ARCHITECT
4 G.C (SEE DWG. A-730 FOR ADDITIONAL INFORMATION)
RFID SHIELDING - SEE RFID APPLICATION NOTE ON FINISH
ALL DOORS AND FRAMES ON SALES FLOOR AND BACK OF HOUSE AREAS TO SCHEDULE - DWG. A511 & PARTITITYPES DWG. A-700 &
5 BE PAINTED TO MATCH ADJACENT WALL. RFID FOR ADDTL. INFO. 572 NORTH BROADWAY
6
G.C. TO FURNISH RSP J-MOLD FOR ALL EXPOSED EDGES (IF NOT EXISTING) OF
NOT WHITE PLAINS, NEW YORK 10603
SALESUSED
AREA WALL PANEL SYSTEMS. REFER TO DETAIL ON FIXTURE DETAILS SHT. FLOOR FINISH LEGEND
FOR MORE INFO.
TEL 914 289 0011
7
G.C. TO PATCH AND REPAIR FLOOR, WHERE WALL HAS BEEN DEMOLISHED, TO
MATCH AND ALIGN WITH EXISTG. & ADD NEW BASE TO MATCH EXISTG.
SYMBOL TAG DESCRIPTION
EXISTING BOH FLOORING TO BE REMOVED, AS REQD., AND REPLACED WITH CT-1 CERAMIC TILE - LEA DARK GREY (24" X 24")
8 NEW TO MATCH EXISTING OR APPROVED SUBSTITUTE PER FINISH SCHEDULE. GROUT: MAPEI COLOR #47 'CHARCOAL GREY'
EXISTING
EXISTING BOH FRP TO REMAIN - PATCH AND REPAIR, AS REQD., TO MATCH (U.O.N.)
9 EXISTG. REPLACE ANY DAMAGED CORNER GUARDS TO MATCH EXISTG.
VINYL COMPOSITE TILE -
FT-1 'MIGRATIONS' BBT T3509 (13" X13"COLOR:
MUSHROOM BEIGE
J.85 K K.34 K.9 L M N O P Q R S T
3'-10" 8'-6" 13'-9" 2'-9" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" CERAMIC TILE - DALTILE VERANDA COLORBODY
FT-1 PORCELAIN (13" X 13")
FIELD TILE
EXISTING
(U.O.N.) GROUT: MAPEI COLOR #46 'CHARCOAL'
EXISTING NEW OPEN EXISTING
EXSTG. MENS
EXISTING NEW MENS MEN'S EXISTG. MENS LIGHTBOX LIGHTBOX OPEN WINDOW NEW MENS EXISTG. KIDS MALL FLOOR FINISH TO CLOSURE LINE. G.C. TO
MEN'S ENTRY OPEN WINDOW SALES AREA OPEN WINDOW WINDOW (WOMENS) WINDOW (KIDS) OPEN WINDOW SALES AREA
113 COORD. PURCHASE AND/OR INSTALLATION
108 109 101 110 111 112 114 102 MALL
CLG. (EXIST.) PT-1 W/LANDLORD'S REP. V.I.F. G.C. TO REPAIR/REPLACE
PT-1 CLG. (EXIST.) PT-1 CLG. (EXIST.) PT-1 CLG. (EXIST.) PT-1 CLG. (EXIST.) PT-1 CLG. (EXIST.) PT-1 CLG. (EXIST.) CLG. (EXIST.) PT-1 CLG. (EXIST.) PT-1
EXISTING ANY MALL TILE DAMAGED DURING CONSTRUCTION,
PT-2 WALLS (EXIST.) PT-1 WALLS (EXIST.) PT-1 WALLS (EXIST.) WALLS (EXIST.) PT-4 (U.O.N.) WITHIN TENANT LEASE LINE.
CT-1 FLOOR (EXIST.) CT-1 FLOOR (EXIST.) MB-1 BASE (EXIST.) FLOOR (EXIST.) FT-1

SF-1 BULKHEAD MB-1 BASE (EXIST.)


PT-1 WALL NOTE:
BASE (EXIST.) MB-1
BASE FINISH LEGEND
WT-1 WALL COLUMN PT-2 MB-1 BASE (EXIST.) SEE STOREFRONT ELEVATION PAINT & FINISHES TO BE COORDINATED WITH H&M PROJ. MGR. PRIOR TO PURCHASE & INSTALLATION
SS-1
LIC # AR0015561
BASE (EXIST.) BASE (EXIST.) MB-1 DRAWING A600 FOR ADDITIONAL
STORERONT FINISHES TAG DESCRIPTION
SALES AREA WALLS, COLUMNS, DISPAY WINDOWS (WHERE SHOWN
BULKHEAD SF-1 MB-1 ON FINISH PLAN):
WALL WT-1 L L L L L EXISTING STAINLESS STEEL BASE - PREFAB
22.63 BASE (EXIST.) SS-1

MATCHLINE

MATCHLINE
NOTE: EXISTING PRE-FAB METAL BASE TO BE REPAIRED AND CLEANED AS

AREA 'B'

AREA 'A'
L L L L L L L REQD, CAREFULLY REMOVE & RELOCATE EXISTING METAL BASE FROM
22.48 NEW MENS WALL PT-2 7 DEMO. WALLS AND RELOCATED TO NEW CONSTRUCTION, WHERE REQD.
OPEN WINDOW BASE (EXIST.) MB-1 EXISTING STOREFRONT
107 VB-1
METAL PANELS TO REMAIN VINYL WALL BASE - COLOR TO MATCH (FT-1)
15'-9"

PT-1 CLG. (EXIST.) PT-2 WALL SEE DETAIL 14/A-710


22.3 EXISTING
MB-1 BASE (EXIST.)
PT-2 WALL STOREFRONT MALL ELEVATION:
PAINTED NAVIGATION
MB-1 BASE (EXIST.) SB-1
22.2 2 L STAINLESS STEEL BRUSHED FINISH BASE
PT-2 WALL
("STORE GUIDE ") WALL PT-2 EXISTING EXISTING BASE TO BE REPAIRED AND CLEANED AAS REQD. SEE
MB-1 7 L
STOREFRONT ELEVATIONS (A600) FOR ADDTL. BASE INFO EXP. 2/28/2025
MB-1 BASE (EXIST.)
M M M
BASE
(EXIST.)
22
7 PAINT AND WALL FINISH LEGEND
M WALL PT-2
PAINT & FINISHES TO BE COORDINATED WITH H&M PROJ. MGR. PRIOR TO PURCHASE & INSTALLATION REVISION:
EXISTING M
DISPLAY WINDOW
106
BASE
(EXIST.)
MB-1
TAG DESCRIPTION
PT-1 CLG. (EXIST.) PT-2 WALL PT-2 WALL PT-2 WALL PT-2 WALL PT-2 WALL PT-2 WALL WALL PT-2 PAINTED NAVIGATION PT-1
PORTAL FITTING ROOM WALL PANELS:
CEILING PNL-1
NOTE: PT-1 WALLS (EXIST.) MB-1 BASE (EXIST.) MB-1 BASE (EXIST.) MB-1 BASE (EXIST.) MB-1 BASE (EXIST.) MB-1 BASE (EXIST.) MB-1 BASE BASE MB-1 CENTERED ABOVE PORTAL WHITE ASH PANEL (FITTING ROOM SERVICE AREA)
(EXIST.) (EXIST.) ("KID'S DEPARTMENT ") 2
SEE STOREFRONT ELEVATION PT-1 PODIUM (EXIST.) SALES AREA CEILING, DISPLAY WINDOW & VOIDS:
DRAWING A600 FOR ADDITIONAL N/A BASE (EXIST.) ℄ PT-1 "WHITE" - NCS S 0500-N ("BENJAMIN MOORE" OC-129 ALABASTER),
STORERONT FINISHES GLOSS MATTE,
25'-0"

PAINTED NAVIGATION (RAL 9003 - 'SIGNAL WHITE' EGGSHELL FINISH FOR WALLS, DISPLAY
2 CENTERED ABOVE PORTAL WINDOW COLUMNS
NEW WOMENS PAINTED NAVIGATION PAINTED NAVIGATION PAINTED NAVIGATION PAINTED NAVIGATION ("MEN'S DEPARTMENT ")
OPEN WINDOW ("FITTING ROOM ") 2 2 CENTERED ABOVE PORTAL PT-2 WALL ("FITTING ROOM ") 2 2 CENTERED ABOVE PORTAL AND FASCIAS. FLAT FINISH FOR CEILINGS.
105 7 ("WOMENS DEPARTMENT ") MB-1 BASE (EXIST.) ("WOMENS DEPARTMENT ") M
SAME AS PT-1 EXCEPT:
PT-1 CLG. (EXIST.) PT-1A USE SEMI-GLOSS FINISH ON DOORS, DOOR FRAMES & WALLS AS N I DCIATED
SALES AREA WALLS:
PT-2
M
"WARM GREY "NCS S 2002 - Y GLOSS MATTE ISSUE DATE:
7 PT-3
SALES AREA WALLS: 06.12.23 FOR REVIEW & APPROVALS
BULKHEAD SF-1 ℄ ℄ "PALE PINK" NCS S 1005-Y60R
21 WALL WT-1
M M M M
M 07.17.23 FOR BIDS & PERMITS
SALES AREA WALLS:
BASE (EXIST.) SS-1 PT-4 "LIGHT BEIGE" NCS S 1002-Y50R
PT-3 WALL ("BENJAMIN MOORE" OC-20 PALE OAK),GLOSS MATTE.
PORTAL PORTAL
EXISTING MB-1 BASE (EXIST.) PT-1 CEILING PT-1 CEILING
TOILET ROOM WALLS:
WOMENS ENTRY PT-6 "DARKER WARM BEIGE" - BENJAMIN MOORE - # AC-1,
104 7 PT-3 WALL WALL PT-3 COASTAL FOG, EGGSHELL FINISH FOR WALLS.
MB-1 BASE PAINTED NAVIGATION BASE MB-1 PAINTED NAVIGATION
PT-1 CLG. (EXIST.) 2 CENTERED ABOVE PORTAL 2 CENTERED ABOVE PORTAL STUCCO WALLS (INTERIOR):
("MEN'S DEPARTMENT ") ("MEN'S DEPARTMENT ") "STUCCO LIGHT BEIGE" (SEE PAINT COLOR "PT-4")
SC-1
FINISH: (2) COATS FINE FINISH / LIGHTLY FLOATED
25'-0"

PAINTED NAVIGATION (SEE "STUCCO FINISH APPLICATION" NOTE THIS DWG.)


2 ("FITTING ROOM + CASHPOINT ")
PT-3 WALL BOH WALLS: (AS REQD.)
MB-1 BASE (EXIST.)
RSP
INPRO G2 BIOBLEND RIGID VINYL SHEET WALL PROTECTION - CHINO ARCH PROJECT NO.: 10835
BULKHEAD SF-1 0258, .040" THK. w/ G2-407 TOP CAP AND G2-409 INSIDE CORNERS.
1 2 5 PRODUCT SEASON: 2024
WALL WT-1 PAINTED NAVIGATION USE SEAM JOINTS BETWEEN SECTIONS. SEE DETAIL 16/ A-710 FOR MORE INFO.
BASE (EXIST.) SS-1 CENTERED ABOVE PORTAL 2 PT-1
PORTAL
2
PAINTED NAVIGATION
("STORE GUIDE ") ("KID'S DEPARTMENT ")
CEILING SALES AREA GRAPHICS: SPACE NO.: 185
APPLIED VINYL GRAPHICS OVER PAINT-REFER TO H&M "COLOR AND
PT-G GRAPHIC INSTALLATION". (FURNISH BY H&M & INSTALL BY G.C) DRAWN BY: JTA
COORDINATE SPEC. WITH LATEST IPS AND INSTALLATION WITH 2018 SCALE: AS NOTED
℄ STORE INSTRUCTIONS.
20 PT-3 PT-3 PT-3 PT-3 PT-3 PT-3 PT-3 M PT-3
WALL WALL WALL WALL WALL WALL WALL WALL
M M M M M M

CEILING & BULKHEAD FINISH LEGEND


L

MB-1 BASE (EXIST.) MB-1 BASE (EXIST.) MB-1 BASE (EXIST.) MB-1 BASE (EXIST.) MB-1 BASE (EXIST.) MB-1 BASE (EXIST.) MB-1 BASE (EXIST.) MB-1 BASE (EXIST.)
PAINT & FINISHES TO BE COORDINATED WITH H&M PROJ. MGR. PRIOR TO PURCHASE & INSTALLATION SHEET TITLE:
WALL PT-3 PAINTED NAVIGATION
EXSTG. WOMENS
OPEN WINDOW
PT-3 WALL BASE (EXIST.) MB-1 2 CENTERED ABOVE PORTAL
TAG DESCRIPTION FINISH FLOOR PLAN
L

MB-1 BASE (EXIST.) ("WOMENS / DIVIDED


103 DEPARTMENT ") BOH CEILING:
PT-1 CLG. (EXIST.) STANDARD WHITE CEILINGS: USG ORION 75 ACOUSTICAL PANELS AT AREA - 'A'
PAINTED NAVIGATION (62150) 2'x2' SQUARE LAY IN TILE FOR WHITE CEILINGS. USE USG DONN
("CLICK & COLLECT ") 2 ACT-1
BRAND DX/DXL ACOUSTICAL SUSPENSION SYSTEM (COLOR TO MATCH).
25'-0"

G.C TO CONTACT H&M VENDOR LISTED ON SHEET A-000 FOR INFO.

PLASTIC
REGARDING LOCAL SUPPLIERS.
PT-3 WALL PAINTED NAVIGATION
2
STOREFRONT FINISH LEGEND
L

CENTERED ABOVE PORTAL

PAPER
MB-1 BASE (EXIST.) ("FITTING ROOM")
PAINT & FINISHES TO BE COORDINATED WITH H&M PROJ. MGR. PRIOR TO PURCHASE & INSTALLATION

TRASH
PT-3 PT-3
WALL WALL
TAG DESCRIPTION

THE MALL AT WELLINGTON GREEN


MB-1 BASE (EXIST.) MB-1 BASE (EXIST.)

STORE NO. US 326 - RED MOD

BLVD.WELLINGTON, FL. 33414


PORCELAIN WALL TILE (STOREFRONT EXTERIOR):

4'-0" X 7'-0"
℄ MANUFACTURER: WAYNE TILE KENSINGTON; SIZE: 2" X 16" (50mm x
400mm) PORCELAIN TILE;

10300 W. FOREST HILL


19 COLOR: IVORY G.C TO FURNISH SAMPLE FOR APPROVAL PRIOR TO
MILLWORK WT-1
DECO TABLE ORDERING

3'-0" X 7'-0"
FOIL

SERVICE
EXISTING 7 TRIM AT EXPOSED CORNERS:

SINK
RFID HW
WOMENS @ ADJACENT 3'-0" X 7'-0"
SALES AREA MANUFACTURER: SCHLUTER (OR APPROVED EQUAL) ; MODEL: RONDEC
SALES WALLS
100 3'-4" X 7'-0" RFID 3'-8" X 7'-0" ED/RO 100 TSI (IVORY) (COLOR TO MATCH TILE)
J.85 K K.34 K.9 L M N O

2024
PT-1 CLG. (EXIST.) NOTE: SC-1 WALL PAINT @ CORNERS
(MB-1) BASE TO REMAIN ON TRIM AT EDGES
PT-3 WALLS (EXIST.) EXISTING WALLS IN NEW PNL-1 WALL
CT-1 FLOOR (EXIST.) 'CLICK & COLLECT STOCK MANUFACTURER: SCHLUTER (OR APPROVED EQUAL) ; MODEL: JOLLY-P,
RFID PAINT
MB-1 BASE (EXIST.) AREA, APPLY (VB-1) TO NEW PVC (IVORY) 100 (COLOR TO MATCH TILE)
WALLS. WALL ABV. 2'-6" @ EDGES
CUBICLES PT-4
P G.C TO FURNISH SAMPLE FOR APPROVAL PRIOR TO ORDERING

SAMPLE WALL
NEW CLICK &
BASE MB-1 1 MANNEQUIN /
PROP STORAGE GROUT @ WALL TILES (STOREFRONT): GROUTING TO MATCH TILE.
COLLECT STOCK 'SOPRO' - #29 HEIL BEIGE OR 'MAPEI' - JASMIN #130 OR 'ARDEX' (TBD.)

PROCESSING AREA
127
PT-1 CLG. (EXIST.) MP-1 STOREFRONT WHITE METAL PANELS:

FACILITIES
PT-1 WALLS (EXIST.) WHITE GLOSS #30
EXISTING
CT-1 FLOOR (EXIST.)
VB-1 BASE (NEW) STUCCO FINISH :
VISUAL
SF-1 STUCCO, 'LIGHT BEIGE' NCS S 1002-Y50R (SEE PAINT COLOR "PT-4")
CHECK-IN
18 (SEE "STUCCO FINISH APPLICATION" THIS SHEET)

NOTE: STOREFRONT FRAME FINISH:


EXISTING STOCK ROOM PT-5 PAINT: RAL CLASSIC 9001 'CREAM WHITE'
FIXTURES TO REMAIN 'AS-IS' NOTE: BENJAMIN MOORE EQUIVALENT: 'WHITE DOWN' #970 (VERIFY WITH
EXISTING NEW
EXISTING FITTING EXISTING EXISTING PROCESSING H&M PROJ, MGR.) SHEET NO:

MATCHLINE

MATCHLINE
A-510
STOCK RM. ROOM STOCK RM. JAN. CL. AREA CLG. (EXIST.)

AREA 'B'

AREA 'A'
G.C. TO PREPARE METAL FRAME FINISH AS REQD, FOR NEW PAINT FINISH,
CLG. (EXIST.)
126 REPLACE 127 CLG. (EXIST.)
126 REPLACE CLG. (EXIST.)
125 REPLACE 124 REPLACE
DAMAGED DAMAGED DAMAGED DAMAGED TO PREVENT PEELING / FLAKING
ACT-1 TILES ONLY. PT-1 CLG. (EXIST.) ACT-1 TILES ONLY. ACT-1 TILES ONLY. ACT-1 TILES ONLY.
BRUSHED STAINLESS STEEL:
PT-1 WALLS (EXIST.) PT-4 WALLS (EXIST.) PT-1 WALLS (EXIST.) PT-1 WALLS (EXIST.) PT-1 WALLS (EXIST.)
SS-1 EXISTING STAINLESS STEEL BASE TO REMAIN. REPLACE DAMAGED TILES TO
FT-1 FLOOR (NEW) CT-1 FLOOR / BASE FT-1 FLOOR (EXIST.) FT-1 FLOOR NEW) FT-1 FLOOR NEW) MATCH EXISTING WHERE NOTED (#4 FINISH)
(EXIST. EXCEPT
VB-1 BASE (EXIST.) MB-1 WHERE NOTED) VB-1 BASE (NEW) VB-1 BASE (NEW) VB-1 BASE (EXIST.)
EXTERIOR WARDROBE FINISH NOTE:(EXISTING PERIMETER WARDROBE REFINISHING)
PAINT & FINISHES TO BE COORDINATED WITH H&M PROJ. MGR. PRIOR TO PURCHASE & INSTALLATION REV. NO:
TAG DESCRIPTION
Q R S T
WOMENS & KID'S DEPARTMENT WARDROBES :
PAINT ALL EXISTING NON-WHITE COLOR WARDROBES IN WOMEN'S & KID'S
DEPARTMENTS TO STANDARD STORE WHITE COLOR:
D.O.B. NO:
FINISH FLOOR PLAN @ AREA 'A' 1 PT-1W
WARDROBES:
"WHITE" - NCS S 0500-N / "BENJAMIN MOORE" ULTRA SPEC SCUFF-X
SCALE: 1/8" = 1'-0" COLOR:OC-129 ALABASTER, MATTE FINISH (EGGSHELL IF MATTE IS NOT
AVAILABLE).
PLAN MEN'S DEPARTMENT WARDROBES :
NORTH EXISTING WOOD COLOR WARDROBES IN MEN'S DEPARTMENT ARE TO REMAIN 'AS-IS' AND BE
PATCHED AND REPAIRED AS REQUIRED.
KEY NOTES FINISH NOTES NOTE:
REFER TO SHT. A-511 FOR FINISH KEY AND GENERAL NOTES.
# DESCRIPTION
ALL EXISTING PARTITIONS TO BE PATCHED AND REPAIRED AS REQUIRED AFTER REMOVAL WORK TO
1 EXISTING FLOORING TO REMAIN, CLEAN & POLISH AS NEEDED.
·
'LIKE - NEW' CONDITION, AND PREPARED TO RECEIVE NEW PAINT FINISH.
LEGEND
G.C. CAREFULLY REMOVE EXISTING BASE FOR RE-USE AT NEW WALL CONSTRUCTION. SYMBOL DESCRIPTION
PAINTED NAVIGATION APPLIED TO WALLS. COORDINATE SPEC. WITH LATEST
2 IPS AND INSTALLATION WITH CURRENT STORE INSTRUCTIONS. COORDINATE · ALL DOORS ARE EXISTING UNLESS OTHER WISE NOTED. PAINT TO MATCH ADJACENT WALL FINISH (SEE
INSTALLATION WITH H&M P.M . NOTE: WALLS TO BE PAINTED PRIOR TO FINISH LEGEND) XX-X FINISH TAG - SEE DWG. A-511
APPLICATION. (SEE FINISH "PT-G") · G.C TO REPLACE ALL EXISTING FLOOR TILES TO MATCH EXISTING THROUGHOUT BACK OF HOUSE.
· GYPSUM BOARD FINISH MUST BE LEVEL (4) FOR ALL PARTITIONS
3 EXISTING FITTING ROOM CABINS, CURTAIN ROD & CURTAINS TO REMAIN. · TRIM OF LIGHT FIXTURES IN FITTING ROOM TO BE PAINTED TO MATCH ADJACENT CEILING. XX-X EXTENT OF PAINTED AND/OR WALL FINISH.
JEFFREY
4
NEW PRE-FAB FITTING ROOM PARTITIONS PROVIDED BY H&M AND INSTALL BY
NOT USED
G.C (SEE DWG. A-730 FOR ADDITIONAL INFORMATION)
FLOOR FINISH NOTE:
· EXISTING SALES AREA FLOORING TO REMAIN - CLEAN AND POLISH AS REQUIRED. PATCH AND REPAIR
X KEY NOTE - SEE THIS DRAWING
TAYLOR
RFID SHIELDING - SEE RFID APPLICATION NOTE ON FINISH
ALL DOORS AND FRAMES ON SALES FLOOR AND BACK OF HOUSE AREAS TO FLOORING, AT DEMOLISHED WALLS, TO MATCH EXISTING.
5 BE PAINTED TO MATCH ADJACENT WALL. · BOH FLOORING TO BE REPLACED WITH NEW TO MATCH EXISTING, UNLESS OTHERWISE NOTED. RFID
SCHEDULE - DWG. A511 & PARTITITYPES DWG. A-700 &
FOR ADDTL. INFO.
ARCHITECT
G.C. TO FURNISH RSP J-MOLD FOR ALL EXPOSED EDGES (IF NOT EXISTING) OF
6 NOT
SALESUSED
AREA WALL PANEL SYSTEMS. REFER TO DETAIL ON FIXTURE DETAILS SHT.
FOR MORE INFO.
WARDROBE FINISH NOTE: (SEE FINISH LEGEND) FLOOR FINISH LEGEND 572 NORTH BROADWAY
· ALL EXISTING PERIMETER WARDROBE FIXTURES TO REMAIN ARE TO BE FINISHED AS NOTED. REPAIR,
7
G.C. TO PATCH AND REPAIR FLOOR, WHERE WALL HAS BEEN DEMOLISHED, TO
MATCH AND ALIGN WITH EXISTG. & ADD NEW BASE TO MATCH EXISTG.
PATCH & CLEAN AND PREPARE SURFACES PER PAINT MANUF INSTRUCTION TO RECEIVE NEW FINISHES.
SYMBOL TAG DESCRIPTION WHITE PLAINS, NEW YORK 10603

EXISTING BOH FLOORING TO BE REMOVED, AS REQD., AND REPLACED WITH CT-1 CERAMIC TILE - LEA DARK GREY (24" X 24")
8 NEW TO MATCH EXISTING OR APPROVED SUBSTITUTE PER FINISH SCHEDULE. FINISH NOTES EXISTING
GROUT: MAPEI COLOR #47 'CHARCOAL GREY'
TEL 914 289 0011
EXISTING BOH FRP TO REMAIN - PATCH AND REPAIR, AS REQD., TO MATCH (U.O.N.)
9 EXISTG. REPLACE ANY DAMAGED CORNER GUARDS TO MATCH EXISTG.
S T U V · ALL DIMENSIONS TO BE VERIFIED IN FIELD PRIOR TO CONSTRUCTION. MATERIALS ARE TO BE SOURCED,
VINYL COMPOSITE TILE -
SUPPLIED AND INSTALLED BY THE CONTRACTOR IF NOTHING ELSE IS SPECIFIED. ALL DEVIATIONS MADE FROM
25'-0" 25'-0" 23'-6" 1'-6" FT-1 'MIGRATIONS' BBT T3509 (13" X13"COLOR:
THIS DESIGN INTENT DRAWING SHOULD BE DISCUSSED WITH THE H&M PROJECT MANAGER / STORE
CORNER GUARD COLORS
TO BE COORDINATED WITH H&M PROJECT MANAGER
DESIGNER.
MUSHROOM BEIGE

'INPRO' VINYL · WALL FINISH CERAMIC TILE - DALTILE VERANDA COLORBODY


PAINT DESCRIPTION PORCELAIN (13" X 13")
CORNERGUARD COLOR AS PER WALL FINISH DRAWING. ALL MATERIAL SUPPLIED & INSTALLED BY CONTRACTOR. FT-1
NEW MENS EXISTG. KIDS EXISTG. KID'S FIELD TILE
OPEN WINDOW SALES AREA OPEN WINDOW BENJAMIN MOORE INPRO · BASE EXISTING
(U.O.N.) GROUT: MAPEI COLOR #46 'CHARCOAL'
114 102 116 #OC 129 #0130 EXISTING SKIRTING TO REMAIN THROUGHOUT, REPLACE DAMAGED TILE TO MATCH EXISTING WHERE
CLG. (EXIST.) PT-1 CLG. (EXIST.) PT-1 CLG. (EXIST.) PT-1 'ALABASTER' 'WHITE SAND' REQUIRED. MALL FLOOR FINISH TO CLOSURE LINE. G.C. TO
WALLS (EXIST.) PT-4
INPRO COORD. PURCHASE AND/OR INSTALLATION
FLOOR (EXIST.) FT-1 NCS S 2000 - N · REFERENCE DOCUMENTS FOR MOUNTING INSTRUCTION FOR ARTICLE SUPPLIED BY H&M REFER TO "STORE MALL
#0380 INSTRUCTION", DOCUMENT SUPPLIED BY H&M. FOR CONSTRUCTION DETAILS AND GENERAL ADHESIVE W/LANDLORD'S REP. V.I.F. G.C. TO REPAIR/REPLACE
NOTE:
BASE (EXIST.) MB-1 'LIGHT GRAY' EXISTING
'GALA' INSTRUCTIONS, REFER TO "STORE INSTRUCTIONS", DOCUMENT SUPPLIED BY H&M. ANY MALL TILE DAMAGED DURING CONSTRUCTION,
SEE STOREFRONT ELEVATION (U.O.N.) WITHIN TENANT LEASE LINE.
INPRO
DRAWING A600 FOR ADDITIONAL NCS S 2502- N · ALL PAINT TO BE BENJAMIN MOORE 'ULTRA' - NO SUBSTITUTIONS
#0151
STORERONT FINISHES 'CONCRETE GRAY'
'GRAYSTONE' BASE FINISH LEGEND
· ALL GYP. BD. CEILINGS NOT MARKED ON THE LAYOUT TO BE PATCHED & PAINTED (PT-1) AS REQD. PAINT & FINISHES TO BE COORDINATED WITH H&M PROJ. MGR. PRIOR TO PURCHASE & INSTALLATION
BENJAMIN MOORE INPRO
· ALL VERTICAL ELEMENTS OF SOFFITS TO BE PAINTED TO MATCH ADJACENT COPLANAR WALL PAINT.
MP-1 BULKHEAD (EXIST.) MP-1 BULKHEAD (EXIST.)
#OC 20
'LIGHT BEIGE'
#0112
'DOVER WHITE'
TAG DESCRIPTION
· WHERE WARDROBE FIXTURES ARE LOCATED, WALL BEHIND THEM NEED NOT TO BE PAINTED. NO NEW SALES AREA WALLS, COLUMNS, DISPAY WINDOWS (WHERE SHOWN
MP-1 MP-1
MATCHLINE

MATCHLINE
WALL (EXIST.) WALL (EXIST.)
INPRO BASE TO BE INSTALLED BEHIND WARDROBE FIXTURES. LIC # AR0015561
AREA 'B'

AREA 'A'
SS-1 BASE (EXIST.) SS-1 BASE (EXIST.) BENJAMIN MOORE MB-1 ON FINISH PLAN):
#1016 IONIC COLUMN #0153 · IT SHALL BE THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO TEST MOISTURE CONTENT OF STAINLESS STEEL BASE - PREFAB
'SANDSTONE' EXISTING
'LIGHT PINK' SUB FLOOR PRIOR TO INSTALLATION OF ALL FINISH FLOORING MATERIALS AND TO MAINTAIN PROPER
EXISTING STOREFRONT EXISTING STOREFRONT NOTE: EXISTING PRE-FAB METAL BASE TO BE REPAIRED AND CLEANED AS
TEMPERATURE AND HUMIDITY LEVELS FOR FLOOR FINISH PER MANUFACTURERS SPECIFICATIONS. REQD, CAREFULLY REMOVE & RELOCATE EXISTING METAL BASE FROM
METAL PANELS TO REMAIN METAL PANELS TO REMAIN NCS S 1005 - Y60R INPRO
#0112 · G.C. TO ADD A PLASTIC LAYER TO BACK OF ALL MIRRORS. DEMO. WALLS AND RELOCATED TO NEW CONSTRUCTION, WHERE REQD.
'PALE PINK'
'DOVER WHITE'
MALL
(2)3'-0" X 7'-0"
· ALL GYP. BD. SURFACES SHALL BE A LEVEL 4 FINISH PRIOR TO PAINTING. VB-1 VINYL WALL BASE - COLOR TO MATCH (FT-1)
H.M. DOOR
INPRO · ALL FINISH MATERIALS AND ALL FLOOR FINISHES IN STORE SHALL COMPLY WITH JURISDICTIONAL SEE DETAIL 14/A-710
PT-2
L 22.8 NCS S 2002 - Y EXISTING
WALL
L #0380 FLAME SPREAD AND SMOKE RATINGS.
MB-1 7 'WARM GRAY'
BASE
22.1 'GALA' STOREFRONT MALL ELEVATION:
(EXIST.)
· WHEN A FINISH CONFLICT OCCURS, THE STANDARDS OF THE HIGHER QUALITY FINISH MUST BE USED. SB-1
https://www.inprocorp.com/products/door-and-wall-protection/ STAINLESS STEEL BRUSHED FINISH BASE
EXISTING EXISTING BASE TO BE REPAIRED AND CLEANED AAS REQD. SEE
PT-2 corner-guards/tape-on-corner-guards/ · ALL COLUMNS COLUMNS TO BE PAINTED AS NOTED ON DRAWINGS.
WALL STOREFRONT ELEVATIONS (A600) FOR ADDTL. BASE INFO
MB-1
M
PT-4 WALL · G.C. RESPONSIBLE TO REPACKAGE, INVENTORY AND PALLETIZE H&M FURNISHED MATERIALS.
BASE
(EXIST.) MB-1 BASE (EXIST.) PT-4 WALL PAINT AND WALL FINISH LEGEND
MB-1 BASE (EXIST.) PAINT & FINISHES TO BE COORDINATED WITH H&M PROJ. MGR. PRIOR TO PURCHASE & INSTALLATION
WALL PT-2 PAINTED NAVIGATION PT-1
PORTAL EXP. 2/28/2025
CEILING
BASE
(EXIST.)
MB-1 CENTERED ABOVE PORTAL
("KID'S DEPARTMENT ") 2
FLOOR PROTECTION DURING CONSTRUCTION: TAG DESCRIPTION
℄ ONCE THE FLOORING IS GROUTED, IT SHOULD BE CLEANED AND PROTECTED AS REQUIRED. PNL-1
FITTING ROOM WALL PANELS: REVISION:
WHITE ASH PANEL (FITTING ROOM SERVICE AREA)
PAINTED NAVIGATION SALES AREA CEILING, DISPLAY WINDOW & VOIDS:
2
PAINTED NAVIGATION
CENTERED ABOVE PORTAL
CENTERED ABOVE PORTAL
("MEN'S DEPARTMENT ") FLOOR TRANSITION FLOOR LEVELING NOTE: PT-1 "WHITE" - NCS S 0500-N ("BENJAMIN MOORE" OC-129 ALABASTER),
GLOSS MATTE,
("WOMENS DEPARTMENT ") M
ACCESSIBILITY NOTE: TENANT TO CONTRACT PSI TO PERFORM A
FLOOR LEVELING TEST TO DETERMINE
(RAL 9003 - 'SIGNAL WHITE' EGGSHELL FINISH FOR WALLS, DISPLAY
WINDOW COLUMNS
PT-4 WALL PT-4 WALL ALL TRANSITIONS OF FLOORING MATERIALS TO MEET FLATNESS/FLOOR PREPARATION REQUIRED AND FASCIAS. FLAT FINISH FOR CEILINGS.
MB-1 BASE (EXIST.) MB-1 BASE (EXIST.) ACCESSIBILITY REQUIREMENTS AND APPLICABLE PRIOR TO INSTALLING TILE
ACCESSIBILITY CODE. SEE SHEET A-000 FOR APPLICABLE SAME AS PT-1 EXCEPT:
PT-1A USE SEMI-GLOSS FINISH ON DOORS, DOOR FRAMES & WALLS AS N I DCIATED
CODES.
SALES AREA WALLS:
WALL PT-4 PT-2
M
M M M BASE
(EXIST.)
MB-1 CORNER GUARDS / R.S.P. NOTES: "WARM GREY "NCS S 2002 - Y GLOSS MATTE
SALES AREA WALLS:
PT-3
"PALE PINK" NCS S 1005-Y60R
PT-1
PORTAL SALES AREA CORNER GUARDS : (SEE SHEET A710 FOR ADDITIONAL INFO.) SALES AREA WALLS: ISSUE DATE:
CEILING
PT-4 WALL
FULL HEIGHT INPRO CORNER GUARDS ON PORTALS AND COLUMN CORNERS, COLOR TO MATCH WALL / PT-4 "LIGHT BEIGE" NCS S 1002-Y50R 06.12.23 FOR REVIEW & APPROVALS
MB-1 BASE (EXIST.) COLUMN FINISH. APPLIED WITH HEAVY DUTY ADHESIVE PER MANUF. INSTRUCTIONS. (G.C TO REFER TO ("BENJAMIN MOORE" OC-20 PALE OAK),GLOSS MATTE.
PAINTED NAVIGATION FINISH PLAN, H&M I.P.S DRAWING FOR CORNER GUARD FINISH AND ADDITIONAL INFORMATION.) TOILET ROOM WALLS: 07.17.23 FOR BIDS & PERMITS
CENTERED ABOVE PORTAL 1 2 5
("MEN'S DEPARTMENT ") REFER TO INPROCORP COLOR GUIDE FOR MATCHING CORNER GUARDS @ PT-6 "DARKER WARM BEIGE" - BENJAMIN MOORE - # AC-1,
www.inprocorp.com/products/door-and-wall-protection/corner-guards/tape-on-corner-guards COASTAL FOG, EGGSHELL FINISH FOR WALLS.
PAINTED NAVIGATION STUCCO WALLS (INTERIOR):
2

EGRESS CORRIDOR
("FITTING ROOM + CASHPOINT ") "STUCCO LIGHT BEIGE" (SEE PAINT COLOR "PT-4")
SC-1
NOTE: FINISH: (2) COATS FINE FINISH / LIGHTLY FLOATED
ALUMINUM CORNER GUARDS SUPPLIED BY H&M AND INSTALL BY G.C. REFER TO H&M "STORE (SEE "STUCCO FINISH APPLICATION" NOTE THIS DWG.)
PAINTED NAVIGATION
CENTERED ABOVE PORTAL 2 PT-1
PORTAL
CEILING
PT-4 WALL PT-4 WALL NOT USED
INSTRUCTIONS" REGARDING GENERAL ADHESIVE & SILICONE INSTRUCTIONS" UNDER "GENERAL CONST. BOH WALLS: (AS REQD.)
("KID'S DEPARTMENT ") MB-1 BASE (EXIST.) MB-1 BASE (EXIST.) DETAILS. (TYP.) INPRO G2 BIOBLEND RIGID VINYL SHEET WALL PROTECTION - CHINO
RSP
NOTE: ADD 0258, .040" THK. w/ G2-407 TOP CAP AND G2-409 INSIDE CORNERS.
NEW BASE
TO MATCH B.O.H. R.S.P. / CORNER GUARDS AREAS : USE SEAM JOINTS BETWEEN SECTIONS. SEE DETAIL 16/ A-710 FOR MORE INFO.
AT NEW INPRO G2 BIOBLEND RIGID VINYL WALL PROTECTION - 0040" THK. W/ G2-407 TOP CAP AND G2-409 SALES AREA GRAPHICS: ARCH PROJECT NO.: 10835
℄ CONSTRUCTION
INSIDE CORNERS. USE SEAM JOINTS BETWEEN SECTIONS. SEE FLOOR DETAIL SHT. FOR MORE INFO. USE APPLIED VINYL GRAPHICS OVER PAINT-REFER TO H&M "COLOR AND
M PT-3 WALL PT-G GRAPHIC INSTALLATION". (FURNISH BY H&M & INSTALL BY G.C) PRODUCT SEASON: 2024
BASE (EXIST.) MB-1 BASE (EXIST.) INPRO G2-150R CORNER GUARDS, SEE A-710, AT ALL OUTSIDE CORNERS (FULL HEIGHT).
COORDINATE SPEC. WITH LATEST IPS AND INSTALLATION WITH 2018
STORE INSTRUCTIONS. SPACE NO.: 185
WALL PT-3 PAINTED NAVIGATION NOTE:
BASE (EXIST.) MB-1 2 CENTERED ABOVE PORTAL GUARDS SECURED WITH CONSTRUCTION ADHESIVE PER MANUFACTURERS INSTRUCTIONS. CEILING & BULKHEAD FINISH LEGEND DRAWN BY: JTA
("WOMENS / DIVIDED
DEPARTMENT ") (NO VISIBLE FASTENERS) PAINT & FINISHES TO BE COORDINATED WITH H&M PROJ. MGR. PRIOR TO PURCHASE & INSTALLATION SCALE: AS NOTED
PAINTED NAVIGATION
("CLICK & COLLECT ") 2
CERAMIC WOOD TILE NOTE: TAG DESCRIPTION
BOH CEILING:
G.C. FLOORING SUBCONTRACTOR TO MIX TILES FROM DIFFERENT BOXES TO EVENLY DISTRIBUTE DYE LOTS. STANDARD WHITE CEILINGS: USG ORION 75 ACOUSTICAL PANELS SHEET TITLE:
PT-4
PLASTIC

WALL (62150) 2'x2' SQUARE LAY IN TILE FOR WHITE CEILINGS. USE USG DONN
PAINTED NAVIGATION MB-1 BASE (EXIST.) ACT-1 FINISH FLOOR PLAN
2 BRAND DX/DXL ACOUSTICAL SUSPENSION SYSTEM (COLOR TO MATCH).
CENTERED ABOVE PORTAL
MIRROR NOTE:
PAPER

("FITTING ROOM") G.C TO CONTACT H&M VENDOR LISTED ON SHEET A-000 FOR INFO. AT AREA - 'B'
TRASH

(ALL WORK / PRODUCTS BY G.C.) REGARDING LOCAL SUPPLIERS.


MGR./SECR.
G.C. APPLY AN EVEN COAT OF "CRL" HEAVY-BODIED MIRROR MASTIC TO WALL/SURFACE WHERE MIRRORS ARE BEEN
STOREFRONT FINISH LEGEND LEGEND & NOTES
INSTALLED. APPLY PRODUCT IN STRICT CONFORMANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION
OFFICE PAINT & FINISHES TO BE COORDINATED WITH H&M PROJ. MGR. PRIOR TO PURCHASE & INSTALLATION
CLG. (EXIST.) SPECIFICATIONS (FURNISH CUT SHEET FOR APPROVAL).
117 REPLACE
4'-0" X 7'-0"

SAFE

℄ DAMAGED
ACT-1 TILES ONLY. TAG DESCRIPTION
G.C. TO APPLY "CRL" CATEGORY II SAFETY BACKING TAPE FOR MIRRORS
LAN
PT-1 WALLS (EXIST.) (APPLY TO BACK OF ALL MIRRORS) OR APPROVED EQUAL.
MILLWORK
RACK
FT-1 FLOOR (EXIST.) (FURNISH CUT SHEET FOR APPROVAL). PORCELAIN WALL TILE (STOREFRONT EXTERIOR):
DECO TABLE
VB-1 BASE (EXIST.) MANUFACTURER: WAYNE TILE KENSINGTON; SIZE: 2" X 16" (50mm x
3'-0" X 7'-0"
SERVICE

7
SINK

400mm) PORCELAIN TILE;

THE MALL AT WELLINGTON GREEN


HW
G.C. TO SECURE J-MOLDING FIRMLY TO STUD LOCATIONS (DO NOT SECURE TO GYP. BD.).
3'-0" X 7'-0"

3'-0" X 7'-0"
COLOR: IVORY G.C TO FURNISH SAMPLE FOR APPROVAL PRIOR TO

STORE NO. US 326 - RED MOD

BLVD.WELLINGTON, FL. 33414


WT-1
RFID 3'-8" X 7'-0"
ADMIN. ALL MIRRORS TO HAVE POLISHED EDGES U.O.N (NO ROUGH EDGES) ORDERING
WALL PAINT HI-LO
OFFICE TRIM AT EXPOSED CORNERS:
SC-1 DRINKING

10300 W. FOREST HILL


FOUNTAIN
CLG. (EXIST.)
118 REPLACE MANUFACTURER: SCHLUTER (OR APPROVED EQUAL) ; MODEL: RONDEC
PNL-1 WALL
5 8 9 DAMAGED
ACT-1 TILES ONLY. ED/RO 100 TSI (IVORY) (COLOR TO MATCH TILE)
TIME
CLOCK
PT-1 WALLS (EXIST.) @ CORNERS
FT-1 FLOOR (EXIST.) TRIM AT EDGES
VB-1 BASE (NEW) STUCCO FINISH APPLICATION: MANUFACTURER: SCHLUTER (OR APPROVED EQUAL) ; MODEL: JOLLY-P,
SAMPLE WALL

MANNEQUIN / T-WAVE T-WAVE

PVC (IVORY) 100 (COLOR TO MATCH TILE)


LOCKERS

PROP STORAGE

2024
@ EDGES
PROCESSING AREA

LOCKERS

NEW STUCCO FINISH TO BE: G.C TO FURNISH SAMPLE FOR APPROVAL PRIOR TO ORDERING
SINK

SUSP.
X-MER
'STUCO-FLEX' BREATHABLE ELASTOMETRIC ACRYLIC SPRAY-ON FINISH, BY STUC-O-FLEX INTERNATIONAL. GROUT @ WALL TILES (STOREFRONT): GROUTING TO MATCH TILE.
FACILITIES

COUCH

(OR APPROVED EQUAL) 'SOPRO' - #29 HEIL BEIGE OR 'MAPEI' - JASMIN #130 OR 'ARDEX' (TBD.)
COAT CONCRETE PAD INSTALLED PER MANUF. INSTRUCTION. COLOR AND TEXTURE TO MATCH NOTED NCS FINISH NUMBER AND /
HANGER
TRANS
FORMER
TRANS
FORMER OR REQUIRED COLOR PER H&M FINISH STANDARDS. MP-1 STOREFRONT WHITE METAL PANELS:
VISUAL
CHECK-IN
TRASH PAPER PLASTIC
1125 1125
PRIOR TO 'STUC - O - FLEX SPRAY ON INSTALLATION SURFACE TO BE PATCHED, REPAIRED, CLEANED THEN EXISTING WHITE GLOSS #30
KVA KVA
REFRIG. MONITOR
MDP
VENDING

PRIMED WITH (2) COATS LATEX PRIMER BY 'BENJAMIN MOORE' OR APPROVED EQUAL STUCCO FINISH :
NOTE: MANUFACTURER: SF-1 STUCCO, 'LIGHT BEIGE' NCS S 1002-Y50R (SEE PAINT COLOR "PT-4")
EXISTING STOCK ROOM
FIXTURES TO REMAIN 'AS-IS' STUC - O - FLEX INTERNATIONAL, INC. (SEE "STUCCO FINISH APPLICATION" THIS SHEET)
NEW
EXISTING EXISTING PROCESSING (W) TOILET (M) TOILET EXISTING EXISTING EXSTG. STAFF EX. ELEC.
17639 NE 67TH COURT
STOREFRONT FRAME FINISH:
MATCHLINE

MATCHLINE

STOCK RM. JAN. CL. AREA CLG. (EXIST.) ROOM ROOM LAN ROOM STAFF AREA LOCKER AREA ROOM REDMOND, WA. 98052
AREA 'B'

AREA 'A'

PT-5 PAINT: RAL CLASSIC 9001 'CREAM WHITE'


CLG. (EXIST.)
126 REPLACE CLG. (EXIST.)
125 REPLACE 124 REPLACE 123 122 121 REPLACE 120 REPLACE CLG. (EXIST.)
120A REPLACE 119 1800.305.1045
DAMAGED DAMAGED DAMAGED DAMAGED DAMAGED DAMAGED NOTE: BENJAMIN MOORE EQUIVALENT: 'WHITE DOWN' #970 (VERIFY WITH
ACT-1 TILES ONLY. ACT-1 TILES ONLY. ACT-1 TILES ONLY. PT-1 CLG. (EXIST.) PT-1 CLG. (EXIST.) ACT-1 TILES ONLY. ACT-1 TILES ONLY. ACT-1 TILES ONLY. N/A CLG. (EXIST.) 1.425.885.5085 H&M PROJ, MGR.)
PT-1 WALLS (EXIST.) PT-1 WALLS (EXIST.) PT-1 WALLS (EXIST.) PT-6 WALLS (EXIST.) PT-6 WALLS (EXIST.) PT-1 WALLS (EXIST.) PT-1 WALLS (EXIST.) PT-1 WALLS (EXIST.) PT-1 WALLS (EXIST.) 1.425.869.0107 (FAX) G.C. TO PREPARE METAL FRAME FINISH AS REQD, FOR NEW PAINT FINISH,
FT-1 FLOOR (EXIST.) FT-1 FLOOR NEW) FT-1 FLOOR NEW) WEANXSIISTNICGOT WALLS (EXIST.) EXSITNIG
WA
NISCOT WALLS (EXIST.) FT-1 FLOOR NEW) FRP-1 WALLS (EXIST.) FRP-1 WALLS (EXIST.) FT-1 FLOOR NEW) EMAIL: info@stucoflex.com TO PREVENT PEELING / FLAKING
VB-1 BASE (NEW) VB-1 BASE (NEW) VB-1 BASE (EXIST.) N/A FLOOR (EXIST.) N/A FLOOR (EXIST.) VB-1 BASE (NEW) FT-1 FLOOR NEW) FT-1 FLOOR (NEW) VB-1 BASE (NEW) SHEET NO:
BRUSHED STAINLESS STEEL:
EXTERIOR N/A BASE (EXIST.) N/A BASE (EXIST.) VB-1 BASE (NEW) VB-1 BASE (NEW)
WALL TILE APPLICATION: EXISTING STAINLESS STEEL BASE TO REMAIN. REPLACE DAMAGED TILES TO

A-511
SS-1
MATCH EXISTING WHERE NOTED (#4 FINISH)

G.C TO APPLY "LATICRETE" DS-307-1121 PRIME-N-BOND (OR APPROVED EQUAL) TO EXISTING PARTITION WARDROBE FINISH NOTE:(EXISTING PERIMETER WARDROBE REFINISHING)
PRIOR TO INSTALLING NEW WALL / BASE TILE. PREP WALL SURFACE PER MANUFACTURER PUBLISHED PAINT & FINISHES TO BE COORDINATED WITH H&M PROJ. MGR. PRIOR TO PURCHASE & INSTALLATION
INSTRUCTIONS.
TAG DESCRIPTION
FINISH FLOOR PLAN @ AREA 'B' 1 RFID APPLICATION: REV. NO:
SCALE: 1/8" = 1'-0" WOMENS & KID'S DEPARTMENT WARDROBES :
PAINT ALL EXISTING NON-WHITE COLOR WARDROBES IN WOMEN'S & KID'S
YSHIELD SHIELDING PAINT WITH INTERIOR GROUNDING KIT ( SEE "E" DRAWINGS). DEPARTMENTS TO STANDARD STORE WHITE COLOR:
(OR APPROVED EQUAL). PREP WALL SURFACE PER MANUFACTURER PUBLISHED INSTRUCTIONS.
PLAN RFID G.C TO COORDINATE WITH H&M P.M. PT-1W
WARDROBES:
"WHITE" - NCS S 0500-N / "BENJAMIN MOORE" ULTRA SPEC SCUFF-X
NORTH NOTE: APPLY SHIELDING PAINT UP TO EXISTING / NEW CEILING COLOR:OC-129 ALABASTER, MATTE FINISH (EGGSHELL IF MATTE IS NOT
AVAILABLE). D.O.B. NO:
MEN'S DEPARTMENT WARDROBES :
EXISTING WOOD COLOR WARDROBES IN MEN'S DEPARTMENT ARE TO REMAIN 'AS-IS' AND BE
PATCHED AND REPAIRED AS REQUIRED.
NEW TILE. SEE
ELEVATION FOR
LOCATIONS - TYP.
NOTE: PROVIDE
"LATICRETE" LATAPOXY
300 ADHESIVE (OR
APPROVED EQUAL) TO
INSTALL TILE ON EXISTING
SURFACE. INSTALL PER
MANUFACTURER
PUBLISHED
INSTRUCTIONS.

PROVIDE CONTINUOUS
"SCHLUTER - JOLLY" EDGE
ANGLE- COLR TO MATCH
ADJACENT TILE COLOR TYP.

EXISTING STAINLESS
STEEL BASE TO REMAIN

STOREFRONT DEMOLITION KEY NOTES STOREFRONT KEY NOTES


NOTE:
A EXISTING PENDANT MOUNTED ILLUMINATED 'H&M' STOREFRONT LOGO SIGN TO 1 8" WIDE X 2" DEEP NEUTRAL PIER WITH BLACK CHANNEL REVEAL (TYP.) PAINT
BE REMOVED - WIRING TO REMAIN FOR NEW SIGN CONNECTION. REVEAL TO 'LIKE-NEW' CONDITION - REPLACE REVEAL TO MATCH, AS REQD. DUE

(TYP.) SF-1 SF-1 (TYP.)


TO NEW CONSTRUCTION.
LEGEND
2 EXISTING STOREFRONT GLAZING TO REMAIN 'AS-IS'; 8" D. X 2" HIGH WHITE

LEASE LINE
PT-5 (TYP.)
METAL GLASS FRAME TO BE PAINTED AS SHOWN. SYMBOL DESCRIPTION
(TYP.) 3 A 5 6 (TYP.) 3 (TYP.) 2 6
5 5 5 EXISTING 6" H. BRUSHED ALUMINUM STAINLESS STEEL STOREFRONT BASE TO
A-600 A-600 A-600
2A
B.O. MALL REMAIN 'AS-IS'. REPLACE DAMAGED BASE (TO MATCH EXISTING), AS REQD. XX-X FINISH TAG - SEE DWG. A-511
BULKHEAD REPLACE EXISTING DAMAGED 6" H. BRUSHED ALUMINUM STAINLESS STEEL
13'-5"
2B
STOREFRONT BASE WITH NEW TO MATCH EXISTING. TYPICAL WHERE REQUIRED
X JEFFREY

2" 2'-2"
ACROSS STOREFRONT. CONSTRUCTION TAG NOTE - SEE DWG. A-600
T.O. STOREFRONT
11'-4"
3 EXISTING POLISHED WHITE BREAK METAL CLADDING AT MALL SIDE OF
STOREFRONT TO BE PROPERLY PREPARED TO RECEIVE NEW STUCCO FINISH (PER TAYLOR

5"±
STUCCO MFR. INSTRUCTIONS)

2'-0"
PT-5 X
(TYP.) SEE DRAWING A-511 FOR 3A EXISTING POLISHED WHITE BREAK METAL CLADDING AT MALL SIDE OF
STOREFRONT TO REMAIN AND RECEIVE 'BODY WORK' REPAIR (REMOVE ALL DENTS
XX DETAIL TAG
ARCHITECT
6
FINISH PLAN LEGEND AND SCRATCHES) AND THOROUGHLY CLEAN AS REQD.
4 LINE OF EXISTING R.U.G. CHECK FOR PROPER OPERATION AND REPAIR AS
4 6
A-600 INFORMATION AND NOTES 4
REQIUIRED. NOTE TO G.C.: 572 NORTH BROADWAY

10'-6"
WHITE PLAINS, NEW YORK 10603
11'-4"
A-600 A-600 4 5 NEW 2'-0" H. PENDANT MOUNTED ILLUMINATED 'H&M' LOGO SIGN G.C TO PATCH AND REPAIR EXISTING MALL FLOORING / MALL BULKHEAD
6 1 5
A-600 A-600 A-600 (TO MATCH EXIISTING). PATCH AND REPAIR SOFFIT AS REQD. IF DAMAGE DURING CONSTRUCTION (AT G.C COST) -TYPICAL
TEL 914 289 0011
6 LINE OF CEILING MOUNTED HUNG CURTAINS (BEYOND)
PT-5
(TYP.)
7
EXISTING 'H&M' RECESSED ILLUMINATED LOGO SIGN TO REMAIN - G.C. TO CHECK
FOR PROPER OPERATION AND REPORT TO H&M PROJECT MANGER OD ANY DARK
NOTE:
SPOTTING IS PRESENT AND IF SIGN LIGHTING NEEDS REPAIR. SEE FINISH PLAN A511 FOR ADDITIONAL STOREFRONT FINISHES.

6" 2"
F.F.
7 7 PT-5 7 0'-0"
A-600 A-600 A-600
(TYP.) 2A 4 (TYP.) 2 (TYP.) 2A (TYP.)
22'-3"± NEW WOMEN'S OPEN WINDOW
WOMEN'S ENTRANCE EXISTING MALL NEUTRAL
WT-1 WT-1 WT-1 PIER
(TYP.) (TYP.) (TYP.)

EXTERIOR STOREFRONT ELEVATION (AT H&M LEASE AREA) 1


SCALE: 1/4" = 1'-0"

LIC # AR0015561

SF-1 (TYP.)

6 PT-5 (TYP.) (TYP.) 3 (TYP.) 2 6


A-600 A-600
B.O. MALL
NEW TILE. SEE
BULKHEAD ELEVATION FOR
LOCATIONS - TYP.
13'-5" NEW STUCCO FINISH. NEW TILE. SEE ELEVATION FOR
SEE ELEVATION FOR LOCATIONS - TYP. NOTE: PROVIDE
T.O. STOREFRONT LOCATIONS - TYP. "LATICRETE" LATAPOXY
PROVIDE CONTINUOUS NOTE: PROVIDE "LATICRETE" 300 ADHESIVE (OR
11'-4" PROVIDE CONTINUOUS
2"

"SCHLUTER - JOLLY" EDGE LATAPOXY 300 ADHESIVE (OR APPROVED EQUAL) TO


(TYP.) PT-5 PT-5 (TYP.) ANGLE - TYP. COLOR TO MATCH APPROVED EQUAL) TO INSTALL
"SCHLUTER - RONDEC" EXP. 2/28/2025
CORNER EDGE REVEAL - INSTALL TILE ON EXISTING
ADJACENT TILE COLOR TILE ON EXISTING SURFACE. SURFACE. INSTALL PER
NOTE: ALIGN WITH EDGE OF TYP. @ CORNERS
INSTALL PER MANUFACTURER MANUFACTURER
4 4 LINE OF EXISTING PIER. COLOR TO MATCH REVISION:
6 PUBLISHED INSTRUCTIONS. PUBLISHED
A-600 A-600 STOREFRONT FRAME ADJACENT TILE COLOR
PROVIDE CONTINUOUS INSTRUCTIONS.
BELOW ( TO BE PAINTED NEW TILE. SEE ELEVATION
"SCHLUTER - JOLLY"
BENJAMIN MOORE, BLACK FOR LOCATIONS - TYP.
10'-6"

EDGE ANGLE(TO MATCH


#2132-10, SEMI GLOSS NOTE: PROVIDE TILE COLOR) - TYP. LINE OF EXISTING
EXISTING "LATICRETE" LATAPOXY NOTE: PROVIDE AND STOREFRONTCONSTRUCTION
STOREFRONT GLASS 300 ADHESIVE (OR SIDES AS REQUIRED PROVIDE CONTINUOUS
APPROVED EQUAL) TO
"SCHLUTER - JOLLY" EDGE
INSTALL TILE ON EXISTING
NEW TILE. SEE ELEVATION ANGLE- COLR TO MATCH
SURFACE. INSTALL PER
FOR LOCATIONS - TYP. ADJACENT TILE COLOR TYP.
MANUFACTURER
PUBLISHED NOTE: PROVIDE EXISTING BRAKE METAL
2"

INSTRUCTIONS. STOREFRONT FINISH EXISTING STAINLESS


"LATICRETE" LATAPOXY 300
F.F. FINISH AS NOTED PER STEEL BASE TO REMAIN
6"

PLAN - TYP. ADHESIVE (OR APPROVED


MALL F.F.
7 (TYP.) 2 2A (TYP.)
7 0'-0" EXISTING BRAKE METAL
EQUAL) TO INSTALL TILE
A-600 A-600 FINISH ON EXISTING SURFACE.
(TYP.) 2A 2A (TYP.) INSTALL PER ISSUE DATE:
MEN'S OPEN WINDOW MEN'S DISPLAY WINDOW WOMEN'S DISPLAY WINDOW NEW WOMEN'S OPEN WINDOW MANUFACTURER
(TYP.) (TYP.) PUBLISHED INSTRUCTIONS. 06.12.23 FOR REVIEW & APPROVALS
WT-1 WT-1
07.17.23 FOR BIDS & PERMITS
INTERIOR STOREFRONT ELEVATION (AT H&M LEASE AREA) 2 TRIM DETAIL 4 TRIM DETAIL 5 TRIM DETAIL 6 TRIM DETAIL 7
SCALE: 1/4" = 1'-0" SCALE:N.T.S @ GLAZING FRAME SCALE:N.T.S @ EDGE OF TILE & STUCCO SCALE:N.T.S @ TILE CORNERS SCALE:N.T.S @ TILE & S.S. BASE

(TYP.) SF-1 SF-1 (TYP.) PT-5 (TYP.) (TYP.) SF-1 (TYP.) SF-1 (TYP.) SF-1
5 5
2 3 A 5 6 2 3 6 2 6 3 6 B.O. MALL
PT-5 A-600 A-600 B.O. MALL PT-5 PT-5 PT-5
ARCH PROJECT NO.: 10835
(TYP.) (TYP.) (TYP.) BULKHEAD (TYP.) (TYP.) (TYP.) (TYP.) (TYP.) (TYP.) (TYP.) BULKHEAD
PRODUCT SEASON: 2024
13'-5" 13'-5"
2'-2"

2'-2"
SPACE NO.: 185
T.O. STOREFRONT T.O. STOREFRONT JTA
DRAWN BY:
2"

2"
11'-4" 11'-4"
5"±

SCALE: AS NOTED
2'-0"

4 6
A-600 A-600 6 SHEET TITLE:
A-600
STOREFRONT
10'-6"

10'-6"
11'-4"

4 ELEVATIONS
A-600
6" 2"

6" 2"

LIGHT BOX LIGHT BOX


F.F. F.F.

THE MALL AT WELLINGTON GREEN


7 7 0'-0" 0'-0"

STORE NO. US 326 - RED MOD

BLVD.WELLINGTON, FL. 33414


A-600 A-600
(TYP.) 2A (TYP.) PT-5 4 20'-0"± PT-5 2 2A (TYP.) PT-5 2 2A (TYP.) PT-5 2
(TYP.) (TYP.) (TYP.) (TYP.) (TYP.) (TYP.)

10300 W. FOREST HILL


MEN'S ENTRANCE
(TYP.) WT-1

INTERIOR STOREFRONT ELEVATION (AT H&M LEASE AREA) 3 INTERIOR STOREFRONT ELEVATION (AT H&M LEASE AREA) 4

2024
SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0"
LEASE LINE

EXTENT OF
(TYP.) SF-1 (TYP.) 3 PT-1
6 (TYP.) 2
MALL BULKHEAD (NIC)
3A 3A (TYP.) 2 3A STUCCO FINISH
(TYP.)
PT-5 B.O. MALL B.O. MALL
(TYP.) BULKHEAD BULKHEAD
13'-5" 13'-5"

2'-2"
T.O. STOREFRONT T.O. STOREFRONT
2"

11'-4" 11'-4"

2"
SHEET NO:

A-600

10'-10"
10'-6"

10'-6"
D D
REV. NO:

2"
6" 2"

F.F. F.F.
6"

6"
ENTRY TO MALL
0'-0" EGRESS CORRIDOR 0'-0"
PT-5 2 (TYP.) PT-5 2 BEYOND (NIC) ANGLED 2B PT-5 2 PT-5 2A (TYP.) 7 PT-5 D.O.B. NO:
(TYP.) (TYP.) (TYP.) BACK (TYP.) (TYP.) (TYP.) (TYP.) (TYP.)

INTERIOR STOREFRONT ELEVATION (AT H&M LEASE AREA) 5 INTERIOR STOREFRONT ELEVATION (AT H&M LEASE AREA) 6
SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0"
(NOT ALL DESCRIPTIONS MAY
SEE RCP SHTS. SEE RCP SHTS. PARTITION TYPE KEY NOTES BE USED IN THIS DRAWING)
SEE RCP SHTS. SEE RCP SHTS. U.S. OF EX'G DECK U.S. OF EX'G DECK
U.S. OF EX'G DECK U.S. OF EX'G DECK NO. DESCRIPTION
14A 23 PER PARTITION 14A 23 PER PARTITION 1 3-5/8" 20GA METAL STUDS @ 16" O.C
TYPE BELOW TYPE BELOW 14A 23 PER PARTITION
TYPE BELOW
2 1-5/8" 20GA METAL STUDS @ 16" O.C
12 14A

6"

6"
2-1/2" 20GA METAL STUDS @ 16" O.C

6"
3

1 SEE RCP SHTS. SEE RCP SHTS. SEE RCP SHTS.

EXTEND GYP. BD. 6" - 8"


FINISHED CLG.
25
SEE CONSTRUCTION
PLAN FOR PARTITION
TYPE FOR OTHER SIDE
FINISHED CLG.
SEE CONSTRUCTION
PLAN FOR PARTITION
TYPE FOR OTHER SIDE
SEE CONSTRUCTION
PLAN FOR PARTITION
TYPE FOR OTHER SIDE
FINISHED CLG.
4 6" 20GA METAL STUDS @ 16" O.C
JEFFREY
5 20GA METAL STUD RUNNER TO MATCH STUD SIZE
BELOW T.O. WARDROBE
AND 6" - 8" PAST SIDES OF 12
OF WALL 25 OF WALL OF WALL 25
6 3/4" THICK F.R PLY. WD.
TAYLOR
WARDROBE
8'-10 1/2"
T.O. WARDROBE
1 STUDS AT 12" O.C. 1 16
7 3/4" THICK F.R PLY. WD. (STAMP SIDE FACING OUT) - DO NOT PAINT ARCHITECT
12 BEHIND WARDOBE

6" - 8"
ONLY IF REQUIRED OR IF 7A EXTEND PLY. WD. FINISH TIGHT TO FLOOR DECK ABOVE
1 STOCKROOM/ 12
WALL IS RATED.
1'-4" X 5/8" THK. F.R.T. VISUAL ROOM 572 NORTH BROADWAY
PLYWOOD STRIP IN LIEU 8 (3) ROWS OF 3/4" THICK X 6" WIDE F.R PLYWOOD
6" WIDE CONTINUOUS WHITE PLAINS, NEW YORK 10603

12'-0"
OF GYP. BD. VERIFY
20GA MTL. GROUND G.C. TO ADD ONE (1) LAYER OF CONT. 3/4" F.R.T. PLYWOOD ON ALL WALLS OF LAN
WITH LOCAL
BEHIND GYP. BD. ONLY IF RM., IN ELECTRICAL ROOM FRT PLYWOOD ONLY WHERE REQUIRED FOR
JURISDICTION THAT
REQUIRED OR IF WALL IS CL G.C. TO PROVIDE 9 ELECTRICAL/DATA/ETC. EQUIPMENT. G.C. TO INSTALL FIRE RATED PLYWOOD FROM TEL 914 289 0011
THIS IS AN ACCEPTABLE
RATED. COORDINATE F.R.T. BLOCKING FINISHED FLOOR TO 8'-0" A.F.F.. G.C. TO INSTALL PLYWOOD "STAMP-SIDE OUT" SO
CONSTRUCTION. IF NOT
HEIGHT WITH WARDROBE BEHIND GYP. BD. AS FIRE RATING STAMP IS VISIBLE AFTER INSTALLATION. (DO NOT PAINT)
OR WALL IS FIRE RATED,
FIXTURE. 30 REQ'D FOR FURNITURE
USE 5/8" THK. GYP. BD. 3 ROWS (MIN) OF 6" WIDE CONTINUOUS 20GA MTL. GROUNDS RUNNING ALONG
COORDINATE HEIGHT & FIXTURES. SEE B.O.H.
FIXTURE WALLS ONLY - SEE CONSTRUCTION PLAN FOR FIXTURE LOCATIONS.
& MILLWORK SHTS. 10
±5'-6 5/8"

SEE CONSTRUCTION WITH WARDROBE NOTE: COORDINATE MTL. GROUNDS HEIGHTS / SPACING WITH FIXTURE HEIGHTS ( SEE
FIXTURE. 12 5 FOR MORE INFO.
PLAN FOR PARTITION INTERIOR ELEVATIONS FOR FIXTURE HEIGHTS )
TYPE FOR OTHER SIDE 5 5 F.R.T. WOOD BLOCKING BEHIND GYP. BD. FOR MOUNTING ALL SALES AREA & FITTING
OF WALL 5 H&M 11 ROOM FIXTURES/ACCESSORIES (AS REQUIRED).
15 15 15
SALES
WARDROBE 26 AREA 26 26 26 12 5/8" GYP. BD FINISH ( TAPE & SPACKLED @ ALL JOINTS )

0'-0" A.F.F. 0'-0" A.F.F. 0'-0" A.F.F. 0'-0" A.F.F. 13 5/8" TYPE "X" GYP. BD FINISH ( TAPE & SPACKLED @ ALL JOINTS )
FINISHED FLOOR FINISHED FLOOR FINISHED FLOOR FINISHED FLOOR
14 5/8" WATER RESISTANT GYP. BD FINISH ( TAPE & SPACKLED @ ALL JOINTS )

NEW WALL - WARDROBE B2 NEW WALL E NEW WALL - STOCK G NEW WALL - MEETING / SEC. RM. H 14A EXTEND GYP. BD. FINISH TIGHT TO FLOOR DECK ABOVE

SCALE: N.T.S. SCALE: N.T.S. SCALE: N.T.S. SCALE: N.T.S. 15 FINISH BASE AS SCHEDULED ( SEE FINISH PLAN AND SCHEDULE )

NEW WALL E1 NEW WALL - STOCK G1 16 SOUND BATT INSUL. BETWEEN STUDS
SCALE: N.T.S. SCALE: N.T.S.
17 R.S.P. FINISH OVER GYP. BD. FINISH (SEE FINISH PLAN FOR SPEC.)
SAME AS 'E' - INSTALL 5/8" GYP. BD. 12 ON BOTH SIDES OF STUD SAME AS 'G' - INSTALL WOOD STRIPS 30 ON EXISTING DEMISING WALL. LIC # AR0015561
PRE-FINISHED WHITE ASH WALL PANELS @ COMMON FITTING ROOM AREA
18 NOTE: SEE FINISH PLAN & FITTING RM. DRAWING FOR LOCATIONS OF PANELS
PRE-FINISHED FITTING ROOM CABIN PANELS
19 NOTE: SEE FITTING ROOM DRAWING LOCATIONS.
PRE-FINISHED 1/2" THK. MDF BD. MOUNTED TO GYP. BD. WALL WITH ADHESIVE TROWELLED ONTO
PRE-FINISHED 20
CABIN PANELS 'N' 'N1' COMMON AREA
WALL PANELS
THE BACK SIDE OF THE MDF. BD. SEE COLUMN DETAILS SHT. FOR MORE INFO.
1/4" THK. SHADOW GAP BETWEEN WALL BASE AND BOTTOM OF MDF. BD WALL
'N2' 'N3' 21
PROTECTION. SEE COLUMN DETAILS SHT. FOR MORE INFO.
SEE RCP SHTS. G.C TO PROVIDE P.T WOOD BLOCKING BEHIND GYP. BD. FINISH FOR MOUNTING ALL
U.S. OF EX'G DECK SEE RCP SHTS. 22 PLUMBING FIXTURES / ACCESSORIES (AS REQUIRED) . COORDINATE PLACEMENT OF
U.S. OF EX'G DECK SEE RCP SHTS. WOOD BLOCKING WITH PLUMBING FIXTURES / ACCESSORIES (SEE TOILET ROOM SHT.)
U.S. OF EX'G DECK
14A 23 PER PARTITION 5/8" TYPE "X" GYP. BD. FINISH TIGHT TO DECK ABOVE FIRE TAPE & CAULK AT TOP OF
TYPE BELOW 23 RATED WALL (TO MATCH UL #465) (SEE DETAILS ON SHT. A-701)
14A 23 PER PARTITION EXP. 2/28/2025
TYPE BELOW (2) LAYERS OF 5/8" TYPE "X" GYP. BD. FINISH TIGHT TO DECK ABOVE FIRE TAPE &
24 CAULK AT TOP OF RATED WALL (TO MATCH UL #411) (SEE DETAILS ON SHT. A-701)
6"

REVISION:
25 ADJACENT CEILING/SOFFIT (IF PRESENT). SEE RCP SHTS. FOR MORE INFO.
SEE CONSTRUCTION SEE RCP SHTS.
SEE RCP SHTS. SEE RCP SHTS.
PLAN FOR PARTITION FINISHED CLG. 26 SCHEDULED FLOORING. SEE FINISH PLAN SHTS. FOR FLOORING TYPES.
FINISHED CLG. FINISHED CLG. SEE CONSTRUCTION
TYPE FOR OTHER SIDE PLAN FOR PARTITION
OF WALL 25 25 SILICONE AT TOP OF 1 7/8" MTL. STUD. WITH 3/4" PLYWOOD AND 5/8" GYP. BD. ON BOTH SIDES. T.O.
TYPE FOR OTHER SIDE 12 27
SEE CONSTRUCTION WALL PANELS, TYP. PARTIAL HEIGHT WALL TO BE CAPPED AND ALIGNED WITH T.O. FITTING ROOM PANELS
1 OF WALL
PLAN FOR PARTITION G.C. TO PROVIDE ADEQUATE PONY WALL SUPPORT FOR FREESTANDING LOW-HEIGHT
1 TYPE FOR OTHER SIDE 28 WALLS.
OF WALL 12 1
1 PLYWOOD SHIM AT TOP OF FITTING ROOM CABIN WALL PANEL TO FILL GAP BETWEEN
18 18

FITTING ROOM COMMON AREA WALL PANELS


PANEL AND WALL. GAP SIZE VARIES; SHIM TO BE ADJUSTED TO SUIT. TO BE PAINTED TO
STUCCO FINISH 29

HT. TO MATCH EXISTING F.R. CABIN WALLS


31 MATCH WALL PANEL. SILICONE ON ALL JOINTS & SEAMS, TYP. SEE FITTING ROOM
(SEE 12
DWG. A-730) 12 12 DETAILS SHT. FOR MORE INFO.
32
H&M 11 11 7 ROWS (MIN) OF 1" X 4" MECHANICALLY FASTENED WOOD STRIPS RUNNING
FITTING (PAINTED TO MATCH ADJACENT WALL) ALONG FIXTURE WALLS ONLY (EXCEPT IN
ROOM NIGHTBOXES. WOOD STRIPS ON ALL NIGHTBOX WALLS) - SEE FIXTURE & BOH PLAN ISSUE DATE:
EXISTING PARTITION

AREA H&M FITTING H&M FITTING 30 FOR FIXTURE LOCATIONS. (F.R.T. PLYWOOD ONLY IF REQ'D BY AHJ)

12'-0"
STOCKROOM 06.12.23 FOR REVIEW & APPROVALS
±7'-11-1/4"

ROOM AREA ROOM AREA NOTE: COORDINATE STRIP HEIGHTS / SPACING WITH STOCK FIXTURE SCREW
LOCATIONS AND ELECTRICAL SERVICES/OUTLETS. REFER TO MEP SHTS. FOR LOCATION
17
OF SERVICES. 07.17.23 FOR BIDS & PERMITS
WHITE ASH PANEL FINISH
(SEE DWG. A-730) RFID SHIELDING, ON NEW WALLS, BETWEEN STUDS AND GYP. BD. FROM FINISHED
FLOOR TO 12'-0" AFF. REFLECTIX 48" X 100' DOUBLE REFLECTIVE INSULATION ROLL
31
12 WITH STAPLE TAB EDGE-ST48100, NEW YORK WIRE COMPANY MODEL #FCS9222-M
13 36" X 84" AL 0.1016MM (MIN.) OR APPROVED EQUAL. (ONLY ON STOCKROOM SIDE
5 OF WALL)
5 28
15 5
15 15 15 15 32 RFID SHIELDING PAINT APPLIED ON EXISTING WALLS, RFID PAINT TO BE GROUNDED
26 WITH 'Y - SHIELD', GS2 GROUNDING PLATE FOR RFD PAINT. PROVIDE #6 GND. WIRE
26 26 26 TO EXISTING GROUND BAR IN LAN ROOM
26
0'-0" A.F.F.
0'-0" A.F.F. 0'-0" A.F.F.
FINISHED FLOOR 0'-0" A.F.F.
FINISHED FLOOR FINISHED FLOOR ARCH PROJECT NO.: 10835
FINISHED FLOOR
NEW WALL - FITTING ROOM CABIN N PRODUCT SEASON: 2024
NEW WALL - B.O.H. L NEW WALL - FITTING ROOM M NEW WALL - RFID MESH SHIELDING Q SPACE NO.: 185
SCALE: N.T.S.
FITTING ROOM CABIN PANELS
PARTITION NOTES: DRAWN BY: JTA
SCALE: N.T.S. SCALE: N.T.S.
SCALE: N.T.S.
NEW WALL - FITTING ROOM N1 1. EXISTING STRUCTURE: SEE EXISTING CONDITION DRAWINGS FOR STRUCTURE HTS. AND
SCALE: AS NOTED
NEW WALL - B.O.H. L1 NEW WALL - FITTING ROOM M1 SCALE: N.T.S.
FITTING ROOM COMMON AREA WALL PANELS NEW WALL - RFID MESH SHIELDING Q1 2.
LIMITING CONDITIONS
FIRESTOPPING SHALL BE THERMAFIBER WOOL INSULATION OR EQUIVALENT.
1 HR. FIRE RATED WALL 3. FIRE CAULKING SHALL BE FIRECODE BRAND FIRECAULK OR EQUIVALENT.
1 HR. FIRE RATED WALL SCALE: N.T.S.
SCALE: N.T.S. SAME AS TYPE 'L' EXCEPT USE KEY NOTE #23
SCALE: N.T.S. NEW WALL - FITTING ROOM CABIN N2 SAME AS TYPE 'Q' EXCEPT USE KEY NOTE #23 4. ALL PIPES , ELECTRICAL CONDUITS, STRUCTURE & DUCTS PENETRATION THROUGH RATED
SHEET TITLE:
NEW WALL - B.O.H. L2 SAME AS 'M' - WALL HEIGHT TO ALIGN WITH EXISTING FITTING ROOM WALLS SCALE: N.T.S. SAME AS TYPE 'N1' EXCEPT USE KEY NOTE #4
NEW WALL - RFID MESH SHIELDING Q2 WALLS SHALL BE FIRE CAULK AROUND ALL EDGES WITH "3M" FIRE BARRIER RATED
FORMING MATERIAL (OR APPROVED EQUAL)
SAME AS TYPE 'Q' EXCEPT USE KEY NOTE #14A
5. G.C. TO PROVIDE ADEQUATE METAL STUDS PER SSMA LIMITED WALL HEIGHT
SCALE: N.T.S.
SCALE: N.T.S. SAME AS TYPE 'L' EXCEPT USE KEY NOTE #14A
NEW WALL - FITTING ROOM N3 STANDARDS FOR INTERIOR NON-STRUCTURAL NON-COMPOSITE WALLS (5 PSF, L/240.)
PARTITION TYPES
SCALE: N.T.S. SAME AS TYPE 'N1' EXCEPT USE KEY NOTE #27
EXISTING WALL - RFID PAINT SHIELDING Q3 6. ALL PARTITIONS SHOWN AS EXISTING TO BE PATCHED AND REPAIRED AS REQ'D. AND
MAINTAIN EXISTING RATING
SAME AS TYPE 'Q' EXCEPT USE KEY NOTE #32
7. BLOCKING IS SHOWN FOR REFERENCE ONLY. EXACT QUANTITY AND O.C. DIMENSIONS
SCALE: N.T.S. SHALL BE COORDINATED WITH FIXTURE SHOP DWGS.
8. NO SCREWING OR ATTACHING TO ROOF DECK. PER LL'S REQ'TS., G.C. TO COORD.
WITH LL'S ON SITE REP.
9. NOTHING IS PERMITTED TO BE ATTACHED TO, SUSPENDED FROM OR PENETRATE THE
ROOF DECK ALL. FRAMING MUST BE ATTACHED TO STRUCTURAL STEEL.
10. G.C TO REFER TO H&M PRODUCT GUIDE LINES AND INTERIOR INSTRUCTIONS BOOKLETS
FOR FURTHER INFORMATION AND DETAILING FOR ALL H&M FIXTURES.

THE MALL AT WELLINGTON GREEN


EXISTING ROOF DECK SEE RCP SHTS. 11. ALL EXTERIOR WALL FUR-OUTS TO RECEIVE MIN. R-19 BATT INSULATION.
12. MAXIMUM ALLOWABLE SPACING FOR CONTROL JOINTS AT

STORE NO. US 326 - RED MOD

BLVD.WELLINGTON, FL. 33414


U.S. OF EX'G DECK
GYP. BD. WALLS = 30'-0"
GYP. BD. CEILING = 50'-0"

10300 W. FOREST HILL


EXISTING STEEL BEAM (ROOF FRAMING)

8" X 20 GA STE STUD CONT.


FASTEN TO FLANGE WITH (2) #

2024
1
10 SCREWS
1
2 1/2" x 20 GA STE STUDS
BRIDGING CONT. (MID-LENGTH
OF KICKER)
B.O. ANGLE PLACED @
+11'-0" A.F.F. ONLY
WHERE THERE IS NO CLG.
ADJACENT TENANT

16 GA CONN ANGLE W/ (2)


# 8 SCREWS EA LEG TYP
1'-0"
(N.I.C.)

3 5/8" x 20 GA STE STUD CONT


W/ #12 SCREWS TO EACH STUD
SEE RCP SHTS.
FINISHED CLG.
H&M SIDE SHEET NO:
SEE CONSTRUCTION PLAN FOR
WALL TYPE

A-700
EX. BEAM

EX. BEAM

EX. BEAM
STUD FRAMING

STUD FRAMING
@ 16" O.C.

@ 16" O.C.

NOTE: 18GA. STUD TRACK - FASTEN TO


EXISTING BEAM W/ (2) #10 SCREWS
NOTHING IS PERMITTED TO BE ATTACHED TO,
SUSPENDED FROM OR PENETRATE THE 18GA. 6" MET STUD TRACK
BETWEEN BEAMS @ 4' OC
REV. NO:
ROOF/FLOOR DECK. ALL FRAMING MUST BE 2" DEEP x 18GA. CONT. SLIP TRACK -
ATTACHED TO STRUCTURAL STEEL, IF REQUIRED BY FASTEN TO STUD TRACK BRACING W/
(2) #10 SCREWS
LANDLORD PARALLEL TO WALL PERPENDICULAR TO WALL

D.O.B. NO:
SECTION DETAIL - STUD SUPPORT - ROOF DECK 1 SECTION DETAIL - STUD SUPPORT - ROOF DECK 2 ELEVATION DETAIL@ STOCK AREA CHANNEL SUPPORT 3
SCALE: N.T.S.
FOR REFERENCE ONLY SCALE: N.T.S.
FOR REFERENCE ONLY SCALE: N.T.S.
FOR REFERENCE ONLY
CASH DESK KEY NOTES
# DESCRIPTION
1 POSTER CHANNEL ABOVE BACK BAR.
G.C TO ALIGN TOP OF CHANNEL WITH BOTTOM
1 1

1'-1112"

1'-1112"
OF EXISTING TRACK LIGHT. COORDINATE FINAL
1 MOUNTING HEIGHT WITH H&M P.M

NOTE: G.C TO PROVIDE CONCEALED WOOD


BLOCKING BEHIND EXISTING PARTITION FOR

BACK BAR
POSTER CHANNEL AS REQUIRED.
JEFFREY

WALL
BACK BAR BACK BAR
3'-312"

3'-312"
3
3
A-702 3
A-702
3 12 12 DASH LINE INDICATES
FULL-HEIGHT CASHWRAP
2 NOT USED TAYLOR
BEYOND HATCHED AREA DENOTES ADA CASHWRAP
3 32" H. (28" MIN - 36" MAX)X 36" W. ARCHITECT
2'-412"

CASH CASH CASH

2'-412"
CASH CASH CASH CASH CASH CASH CASH CASH
REGISTER REGISTER REGISTER REGISTER REGISTER REGISTER REGISTER REGISTER REGISTER REGISTER REGISTER COORDINATE WITH H&M
3

2'-8 1/2"
F F 30"x48" SIDE APPROACH TO H.C. ACCESSIBLE
4 3A
FRONT COUNTER FRONT COUNTER FRONT COUNTER SECTION OF CASHWRAP. 572 NORTH BROADWAY
3'-2" 3'-2"
G.C. TO FURNISH MPSS CAP FOR CASHWRAP WHITE PLAINS, NEW YORK 10603
CLEAR 1B CLEAR 2D 4
A-702 KICK TO ELIMINATE GAP BETWEEN CASHWRAP
A-702 8 & SALES FLOOR.
1'-1112" 3'-3 1/2" 2'-4 1/2"
TEL 914 289 0011
3A 6 7 7 3A 6 6 7
(3'-0" MIN.) MPSS =
MIRROR POLISHED STAINLESS STEEL #8 FINISH.

-A- EQ.
-C- EQ.
TYPCAL SIDE ELEVATION - ADA CASHWRAP 3 FURNISH SAMPLE FOR APPROVAL PRIOR TO
FABRICATION
EQ.

EQ.
-A-
10'-6" EQ.

EQ. EQ.
-C- EQ.
SCALE: 1/4" = 1'-0"
5 NOT USED
10'-6"
CHANNEL LENGTH 28'-10 1/2"
1
5A NOT USED
1 POS PACKAGE 24'-7"x 4'-7"

5B NOT USED
H&M PROJ. MGR. PRIOR TO INSTALLATION

H&M PROJ. MGR. PRIOR TO INSTALLATION


DIMN. TO BE CONFIRMED WITH

DIMN. TO BE CONFIRMED WITH

LINE OF COLUMN
6 GC TO REMOVE WOODEN SUPPORT PLANKS
THAT CONNECT THE FRONT AND REAR KICK

SEE CEILING PLAN


SEE CEILING PLAN

PLATES UNDER THE FOLDING SECTION OF EACH


POSTER CHANNEL

POSTER CHANNEL
CASH WRAP SECTION

7 GC TO INSTALL ANGLE BRACKETS IN THE


BACK BAR CORNERS OF FOLDING SECTIONS TO REINFORCE
BACK BAR STRUCTURAL INTEGRITY OF CASH WRAP
LIC # AR0015561
8 G.C. TO DRILL HOLE AND ADD GROMMET (IF NOT
3'-112"

ALREADY EXISTING) TO PULL WIRES FOR TEMP.


2'-812"

2'-812"
FRONT COUNTER FRONT COUNTER FRONT COUNTER
REGISTERS. GROMMET COVER FINISH TO MATCH
CASHWRAP BASE. REFER TO 'MEP' SHTS. FOR
LOCATIONS.
3'-2" 3'-2"
9 BUILT -IN FIELD SERVICE DESK ELECTRICAL
OUTLETS (SERVICE POINT) TO BE PRE-WIRED IN

3 4 3 4 -D- 4
FLOOR

-B- SEE DRAWING A-761 FOR 37'-1"±


SEE DRAWING A-761 FOR
NEW CASHPOINT BACKWRAP SUPPLIED BY
H&M AND INSTALLED BY G.C.

NOTES
ADDITIONAL MEP ADDITIONAL MEP EXP. 2/28/2025
GC TO REMOVE WOODEN SUPPORT PLANKS THAT
INFORMATION AND NOTES INFORMATION AND NOTES CONNECT THE FRONT AND REAR KICK PLATES UNDER
THE FOLDING SECTION OF EACH CASH WRAP SECTION,
REVISION:
PLAN/ELEVATION - CASHWRAP 1 PLAN/ELEVATION - CASHWRAP 2 TO ALLOW CLEAR SPACE FOR EC TO INSTALL
RECEPTACLES AND DATA BACK BOXES ON INTERIOR
SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" FACE OF REAR KICK PLATES. PLANKS UNDER REGISTER
SECTION MAY BE LEFT AS IS. GC TO INSTALL ANGLE
BRACKETS IN THE CORNERS OF FOLDING SECTIONS TO
REINFORCE STRUCTURAL INTEGRITY OF CASH WRAP

COORDINATE CASHWRAP DIMENSIONS WITH FIXTURE


PLAN & H&M PRODUCT HANDBOOK

G.C. TO REMOVE SHIPPING SLATS IN CASHWRAP


PRIOR TO ANY WORK BY E.C.
ALL FIXTURES PROVIDED BY H&M AND INSTALLED BY
G.C UNLESS OTHER WISE NOTED. G.C TO REFER TO
H&M HANDBOOKS FOR ADDITIONAL INFORMATION.
ISSUE DATE:
06.12.23 FOR REVIEW & APPROVALS
REFER TO H&M FURNISHED "IPS DRAWINGS AND 07.17.23 FOR BIDS & PERMITS
COORDINATE WITH H&M STORE INSTALLATION,
INSTRUCTION & CONSTRUCTION MANUALS.
COORDINATE WITH FIXTURE VENDOR AND H&M
ROOM DIVIDER
PROJECT MGR. FOR ADDITIONAL INFORMATION.
BRACKET AT CEILING
AND FLOOR- SEE
DETAIL '2/A750' PAINT ARCH PROJECT NO.: 10835
TO MATCH CEILING
1'-1112"

TRASH PAPER PLASTIC


PRODUCT SEASON: 2024
PROVIDED BY H&M RECYCLE BIN - SEE CLICK & COLLECT CURVED METAL SPACE NO.: 185
AND INSTALLED BY WARDROBE ROOM DIVIDER
DETAIL 4/A741 FOR
G.C. ADDTL. INFO. STORAGE PROVIDED PROVIDED BY H&M DRAWN BY: JTA
12'-4" AND INSTALLED BY
11'-9" BY H&M AND SCALE: AS NOTED
INSTALLED BY G.C. PROVIDED BY H&M G.C.
LENGTH OF CURTAIN 14'-10" AND INSTALLED BY
G.C.
1'-0" EQ. EQ. 1'-0"
4F
A-702 -E- 5H
A-702 -G- SEE FIXTURE PLAN
SHEET TITLE:
FIXTURE, CASHWRAP,
LENGTH OF CURTAIN
PERF. METAL CURTAIN MISC. DETAILS
6K
A-702 -J- AND INTER. ELEV.

-E- -G-
OPEN BEYOND
PERF. METAL CURTAIN

THE MALL AT WELLINGTON GREEN


DIVIDER AT SELF CHECKOUT -
EXISTING PODIUM - PATCH

STORE NO. US 326 - RED MOD

BLVD.WELLINGTON, FL. 33414


6L SEE DETAIL 2/A750 * H&M
NEW PODIUM END CAP OVER AND REPAIR AS REQUIRED TO
A-702 GUIDELINE FOR ADDL. INFO. 'LIKE-NEW' CONDITION AND
OPEN END OF MODIFIED

10300 W. FOREST HILL


6L PODIUM WITH 3/8" THK. MDF PREPARE FOR NEW FINISH
A-702 BOARD OVER 3/4" THK. FRT PT-1
PLYWOOD WITH BLOCKING AS
REQD. TO BE INSTALLED WITH GLOSS FINISH
NO VISIBLE ATTACHMENTS STOREFRONT
METAL CEILING
SEE CEILING PLAN

SEE CEILING PLAN

DISPLAY

2024
EQ. EQ. CURTAIN PLATFORM
CLICK & COLLECT BRACKET
SEE CEILING PLAN

OPEN FIXTURE PROVIDED


SALES AREA SUPPORT POST
BY H&M AND
CLICK & COLLECT WARDROBE

CLICK & COLLECT WARDROBE

CLICK & COLLECT WARDROBE

CLICK & COLLECT WARDROBE

CLICK & COLLECT WARDROBE

CLICK & COLLECT WARDROBE

CLICK & COLLECT WARDROBE

CLICK & COLLECT WARDROBE

INSTALLED BY G.C. CURVED METAL


PERF. PANELS
SALES AREA
9 FIXTURE SEE PT-1
FIXTURE PLAN
SERVICE DESK
RECYCLE GLOSS FINISH
CENTER
METAL FLOOR
4"

BRACKET
SERVICE POINT DESK & RECYCLE CENTER FIN. FL. FIN. FL.
CLICK & COLLECT WARDROBE FIXTURES (8) EXISTING PODIUM
4"

4"
SALES AREA CONSTRUCTION
EXTENT OF DIVIDER CURTAIN
COORDINATE WITH H&M
SEE DWG. A510 FOR FINISH INFORMATION -K- -L-
-F- -H- SHEET NO:

PLAN/ELEVATION - CLICK & COLLECT SERVICE DESK 4 PLAN/ELEVATION - CLICK & COLLECT WARDROBE 5 DIVIDER CURTAIN @ SALES AREA 6 TYPICAL DETAIL @ END OF DISPLAY WINDOW PODIUM 7
A-702
SCALE: 6"=1'-0
SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" REV. NO:

SEE DRAWING A-761 FOR SEE DRAWING A-750 FOR D.O.B. NO:
ADDITIONAL MEP ADDITIONAL METAL DIVIDER
INFORMATION AND NOTES INFORMATION
NOTE TO G.C.
INSTALL 1/8" THK. FRAME, THEN INFILL FIELD AREA WITH 1/8"
ARDEX (OR SIMILAR) FOR MAT TO SIT LEVEL IN THE SPACE

SALES AREA VESTIBULE


5/8" GYP. BD. ON METAL STUD 5/8" GYP. BD. ON METAL STUD
FRAMING. REFER TO CONSTRUCTION FRAMING. REFER TO CONSTRUCTION NEW 3/8" CERAMIC WEATHER TIGHT SADDLE
PLAN AND WALL TYPES FOR WALL PLAN AND WALL TYPES FOR WALL 1/8" STAINLESS STEEL NEW MALL TILE
TILE FLOORING SEE DOOR SCHEDULE STRIP BY SCHLUTER
CONSTRUCTION. CONSTRUCTION. FROM LEASELINE
GLASS VESTIBULE DOOR TO CL OF CLOSURE CL OF CLOSURE LINE
INPRO G2-407 TOP TRIM AT TOP SCHLUTER DILEX-AKWS
INPRO G2-407 TOP TRIM AT TOP OF CONSTRUCTION JOINT. 1/4" STAINLESS STEEL LINE BY G.C.
OF R.S.P. COLOR TO MATCH R.S.P. R.S.P. COLOR TO MATCH R.S.P. COLOR TO MATCH
ADJACENT TILE.
STRIP BY SCHLUTER
NEW 3/8"
MT-1 1/4" STAINLESS STEEL
STRIP BY SCHLUTER JEFFREY
CENTER OF ALL ELECTRICAL
NEW 3/8" CERAMIC CERAMIC TILE EXIST. SLAB
TAYLOR
NOT USED
OUTLETS/SWITCHES TO BE

NOT USED NOT USED


TILE FLOORING FLOORING NEW 3/8" CERAMIC
MOUNTED AT 44" A.F.F. REFER TO TILE FLOORING
ELECTRICAL SHEETS FOR MORE CORNER GUARD TOP CAP TO BE
EXIST. SLAB
INFORMATION INSTALLED ON GYP. BD. ARCHITECT
INPRO G2-161TC TOP CAP. TOP OF
TOP CAP TO ALIGN WITH
R.S.P. FURNISHED AND INSTALLED ADJACENT R.S.P. TOP TRIM
BY G.C. R.S.P. TO BE GLUED TO 572 NORTH BROADWAY
ADJACENT GYP. BD. WALL PER INPRO G2-150R GUARDS ON
MANU. INSTRUCTIONS. REFER TO OUTSIDE CORNERS IN B.O.H. TO U.S.
E X I S T . C O N C R E T E S L A B WHITE PLAINS, NEW YORK 10603
E X I S T . E X I S T . C O N C R E T E S L A B
FINISH PLANS - "RSP" FOR MORE OF CEILING. INSTALLED PER MANU. C O N C R E T E
INFORMATION INSTRUCTIONS COLOR TO MATCH S L A B TEL 914 289 0011
RSP. SEE NOTE ON FINISH PLAN LANDLORD TO PROVIDE 1" DEPRESSION FOR WALK-OFF MAT OR APPROVED
NOTE: REGARDING EQUAL; VERIFY LOCATION OF DEPRESSION IN FIELD. G.C. TO ADJUST
G.C. TO NOTIFY ARCHITECT OF "CORNER GUARDS / R.S.P." DEPRESSION & INFILL AS NECESSARY FOR PROPER INSTALLATION OF
ANY ELECTRICAL EQUIPMENT TO APPROVED WALK-OFF MAT. SEE STOREFRONT SECTIONS FOR MORE INFO
R.S.P. FURNISHED AND INSTALLED BY
A.F.F.

BE INSTALLED THAT INTERFERES


49"

TO CENTERLINE

GC. R.S.P. TO BE GLUED TO


WITH WALL BASE. G.C. SHALL
FLOOR TRANSITION: CONSTRUCTION JOINT 11 FLOOR TRANSITION: TILE TO RECESSED MAT 6 FLOOR TRANSITION: ENTRY AREA 1
HOLD

ADJACENT GYP. BD. WALL. REFER TO


1/4"

NOT CUT WALL BASE TO ALLOW


FINISH PLANS FOR "R.S.P."
44"

FOR INSTALLATION OF ANY


ELECTRICAL EQUIPMENT LOCATIONS SCALE: 6" = 1'-0" SCALE: 3" = 1'-0" VESTIBULE SCALE: 3" = 1'-0" STOREFRONT
BACK OF HOUSE WALL BASE. BASE
REFER TO CONSTRUCTION PLAN TO EXTEND TO CORNER NOT TO
AND WALL TYPES FOR WALL OVERLAP. DO NOT INSTALL WALL
BASE OVER CORNER GUARD. REFER
NOTE TO G.C.
CONSTRUCTION. INSTALL 1/8" THK. FRAME, THEN INFILL FIELD AREA WITH 1/8"
TO FINISH PLANS FOR MORE
INFORMATION. ARDEX (OR SIMILAR) FOR MAT TO SIT LEVEL IN THE SPACE
BACK OF HOUSE WALL BASE. EXTERIOR VESTIBULE
REFER TO FINISH PLANS FOR EXIST. JOINT. G.C TO PROTECT
NOTE:
MORE INFORMATION DURING CONSTRUCTION 1/8" STAINLESS STEEL
USE INPRO G2-160RD SURFACE SALES EXTERIOR OR
MOUNT END WALL PROTECTOR STRIP BY SCHLUTER AREA MALL CORRIDOR
AT LOUNGE PORTAL AND NEW FLOORING MT-1
WHERE (2) CORNER GUARDS WEATHER
ARE REQUIRED AT END WALL.
TIGHT SADDLE
'A' 'B' GLASS ENTRY
DOOR BY
TENANT
SEE DOOR
SCHEDULE
LINE OF DOOR
FRAME BEYOND
CENTER LINE OF
DOOR JAMB
LINE OF DOOR LIC # AR0015561
EXIST. FRAME BEYOND
NEW 3/8"
WALKWAY

NOT USED NOT USED NOT USED


CERAMIC TILE
DETAIL - INRPO RIGID SHEET VINYL WALL PROTECTION @ BOH 16 FLOORING PATCH / REPAIR
EXISTING CONCRETE
FINISH TO MATCH
SCALE: 6" = 1'-0" FOR REFERENCE ONLY / REFER TO H&M STORE INSTRUCTIONS
EXISTING

E X I S T . C O N C R E T E S L A B
EXISTING CONCRETE
E X I S T . C O N C R E T E S L A B FLOOR SLAB.
( ) - Denotes Millimeters LANDLORD TO PROVIDE 1" DEPRESSION FOR WALK-OFF MAT OR APPROVED
EQUAL; VERIFY LOCATION OF DEPRESSION IN FIELD. G.C. TO ADJUST
DEPRESSION & INFILL AS NECESSARY FOR PROPER INSTALLATION OF
INPRO 'TAPE ON CORNER GUARD APPROVED WALK-OFF MAT. SEE STOREFRONT SECTIONS FOR MORE INFO
ROGID VINYL' EXP. 2/28/2025
COLOR TO MATCH ADJACENT
WALL FINISH
NOTE: REVISION:
INSTALL CORNER GUARDS WITH 5/8" GYP. BD. ON METAL STUD
HEAVY DUTY ADHESIVE PER
MANUFACTURERS INSTRUCTIONS
FRAMING. REFER TO CONSTRUCTION
PLAN AND WALL TYPES FOR WALL
WIDE EXPANSION / CONSTRUCTION JOINT 12 FLOOR TRANSITION: RECESSED MAT TO EXTERIOR 7 FLOOR TRANSITION: SALES AREA TO EXTERIOR 2
CONSTRUCTION. SCALE: 3" = 1'-0" VESTIBULE SCALE: 3" = 1'-0" SALES AREA
SCALE: N.T.S. FOR REFERENCE ONLY
'INPRO' CORNER GUARD

INPRO 'TAPE ON CORNER GUARD


ROGID VINYL'
COLOR TO MATCH ADJACENT
WALL FINISH TOILET B.OH.
HALLWAY
48"

NOTE: ROOM
'INPRO' CORNER GUARD

INSTALL CORNER GUARDS WITH


HEAVY DUTY ADHESIVE, SPREAD
GLUE OVER THE FULL LENGTH OF
CORNER GUARD PROFILE. PER NEW MARBLE
SADDLE
48"

MANUFACTURERS INSTRUCTIONS TILE RECESSED


MAT HEIGHT DIFF. OF ISSUE DATE:
ALUMINUM BASE ATTACHED TO WALL, THRESHOLD NOT
PROVIDED BY H&M INSTALLED BY G.C. 1/8" STAINLESS STEEL NEW 5/16" CERAMIC TO EXCEED 1/2" 06.12.23 FOR REVIEW & APPROVALS
GYP. BD. WALL. REFER TO FINISH TILE FLOORING
PLANS FOR COLOR NO CAULKING. STRIP BY SCHLUTER MT-1 07.17.23 FOR BIDS & PERMITS
NEW BOH FLOORING. REFER
REFER TO CONSTRUCTION PLAN NOTE: TO FINISH PLAN FOR MORE
NEW 3/8" CERAMIC EXIST. SLAB
AND WALL TYPES FOR WALL
CONSTRUCTION.

SALES AREA WALL / COLUMN BASE


IN FITTING ROOM ONLY: G.C. TO
PROVIDE CAULKING AT TOP AND
BOTTOM COLOR TO MATCH ADJACENT
SURFACE.
FINISH FLOOR
TILE FLOORING

NOT USED NOT USED FLOORING TYPE

SALES AREA WALL BASE. REFER TO E X I S T . C O N C R E T E S L A B


FINISH PLANS FOR MORE EXIST. SLAB
NOTE:
INFORMATION E X I S T . C O N C R E T E S L A B
COORDINATE CORNER GUARD COLOR
WITH WALL COLOR (SEE FINISH PLAN), EPOXY MORTAR BED ARCH PROJECT NO.: 10835
H&M PROJECT MANGER AND
'INPRO' COLOR CHART @ PRODUCT SEASON: 2024
185
'C' 'D' www.inprocorp.com/products/
door-and-wall-protection/corner-guards/
tape-on-corner-guards
PRE-FAB ALUM. BASE 13 FLOOR TRANSITION: RECESSED MAT TO TILE 8
FLOOR TRANSITION: TILE TO BOH FLOORING 3
SPACE NO.:
DRAWN BY: JTA
SCALE: 3" = 1'-0" VESTIBULE
SCALE: N.T.S. FITTING ROOM
SCALE: 3" = 1'-0" TOILET ROOM SCALE: AS NOTED

SHEET TITLE:
SALES DOOR B.O.H.
AREA THRESHOLD FLOORING, BASE &
WALL PROTECTION
STAINLESS STEEL ANGLE FLUSH HEIGHT DIFF. OF
DETAILS
JOINT TO BE COVERED WITH WITH TOP OF TILE FLOORING THRESHOLD NOT TO
RIGID SHEET PANEL, WHERE AT TRANSITION TO BOH EXCEED 1 1/2"
PAINTERS FILLER AND APPLICABLE
PAINTED TO MATCH WALL FLOORING
BUILT UP FLOOR FOR
COLOR FLUSH TRANSITION
COVED PROFILE 4" H. NEW 3/8" CERAMIC TILE
RUBBER BASE FLOORING NEW BOH FLOORING.
CORNER BEAD PAINTED

THE MALL AT WELLINGTON GREEN


REFER TO FINISH PLAN
SAME COLOR AS WALL EXIST. SLAB FOR MORE FLOORING

STORE NO. US 326 - RED MOD

BLVD.WELLINGTON, FL. 33414


FINISH FLOOR TYPE

10300 W. FOREST HILL


'INPRO' - CORNER
GUARD SAME COLOR AS
WALL E X I S T . C O N C R E T E S L A B

TYPICAL CORNER BEAD @ G.B. CORNERS 'E'

2024
DETAIL - INRPO VINYL WALL PROTECTION @ SALES AREA 17 RUBBER BASE 14 FLOOR TRANSITION: TILE TO BOH FLOORING 4
SCALE: 6" = 1'-0" FOR REFERENCE ONLY / REFER TO H&M STORE INSTRUCTIONS SCALE: 3" = 1'-0" BOH SCALE: 3" = 1'-0" SALES AREA

WALL TILE GYP. BD. FINISH EXTERIOR B.OH.


ADHESIVE, AS THIN AS
POSSIBLE PAINT SILICONE COLOR
SEAL WITH GROUTING OR SAME AS WALL SHEET NO:

A-710
SILICONE ( PAINT WITH WALL
COLOUR) NATIONAL GUARD
CERAMIC TILE BASE POLISH/ REPAIR PRODUCTS #513 SADDLE
FURNISHED BY H&M AND EXISTING CONCRETE THRESHOLD - MILL ALUM. OR
ADHESIVE, AS THIN AS INSTALLED BY G.C. PER STORE FINISH TO MATCH APPROVED EQUAL
5 1/2"

5 1/2"

POSSIBLE INSTRUCTIONS. CORNERS TO EXISTING


BE MITERED.

NOT USED EXISTING SKIRTING (TO BE


KEPT IN LIGHT REBUILTS)
PAINTED AS ADJACENT
SKIRTING
NOT USED G.C TO APPLY "LATICRETE"
PRIME-N-BOND AT TILE BASE
LOCATIONS ONLY
(SEE DWG. A-521 FOR SPEC.)
EXISTING SLAB

NOT USED NEW BOH FLOORING. REFER


TO FINISH PLAN FOR MORE
FLOORING TYPE REV. NO:

12-16 FINISH FLOOR

E X I S T . C O N C R E T E S L A B

D.O.B. NO:

WALL TILE WITH TILE BASE 19 TILE BASE 15 FLOOR TRANSITION: BOH FLOORING TO EXTERIOR 5
SCALE: 3" = 1'-0" SCALE: 3" = 1'-0" BOH SCALE: 3" = 1'-0" BOH
SEE PLAN
FITTING ROOM NOTES SYM. LEGEND
14
A-730 # NOTE REFERENCE
1. ALL CABIN ROOM FITTINGS ARE SUPPLIED BY H&M/ INSTALLED BY G.C. NEW BACK MIRRORS, MIRROR
SEE PLAN 20 3'-8" w/ LIGHT, SERVICE AREA PANELS ARE SUPPLIED AND INSTALLED BY G.C. VERIFY FIXTURES, E.C.
1 (TYP.) ROUGH-IN WITH FLOOR PLAN LAYOUT. WHITE ASH FITTING ROOM WALL PANEL ( SEE FIXTURE SCHEDULE FOR MORE INFO. )
14 3

4'-9"
A-730 A-730 (OPP 2. G.C. IS RESPONSIBLE FOR PROVIDING ALL BRACING/ BLOCKING REQUIRED BY CODE AND
6 STRUCTURAL NECESSITY FOR ALL FIXTURES AFFIXED TO WALLS.
CG
3'-11"± 18 HAND) CORNERGUARD-COLORTOMATCHADJACENTWALFN
ISIHS(EEFXITURESCHEDULEFORMOREN
I FO).
6 4 EX. F.R. CUBICLE 16 3'-10"

SEE PLAN
SEE PLAN
3 15 3. COORDINATE SPACING & FREQUENCY OF BLOCKING FOR FITTING ROOM ACCESSORIES w/ H&M ON
10
2 2 SITE. NO. GENERAL FITTING ROOM NOTES

5"
11'-5"
A730
7 14 A-730 13 4. G.C. TO CAULK AROUND ALL FIXTURES IN FITTING ROOMS. CAULK ILLUMINATED MIRRORS WHEN NEW SOLID CORE WOOD DOOR - 6'-8" H. X 2'-4" W. TO BE UNDERCUT 1" - INSTALL LEVER SET; 'VIZILOK'
5 TYP.
4 5 7'-10" 16 FRONT PANELS ARE IN OPEN POSITION. 1 HEAVY DUTY ADA DOOR PRIVACY LOCK WITH OCCUPANCY INDICATOR OR APPROVED EQUAL
JEFFREY

5'-5"
20 5. ATTACH HANDICAP BENCH TO WALL (NO OTHER FITTING ROOM BENCHES TO BE SECURED TO

EX. F.R. CUBICLE


7 WALLS). NEW WOOD DOOR FRAME & BLOCKING - BUILD-UP EXISTING PARTITIONS AT OPENINGS FOR PRECISE
15 5 A-730 2 FIT OF NEW WOOD DOOR
TAYLOR

4'-3"±
1 2 EQ. 5'-3" EQ. 6. ALL PLAN DIMENSIONS ARE EXISTING AND TO VERIFIED IN FIELD.
17 FITTING ROOM SURFACE MOUNTED LIGHT TUBES. @ 1'-6" AFF) FURNISHED BY H&M AND INSTALLED BY
4 A-730 6 7. CENTER LINE OF J-BOX FOR FITTING ROOM ILLUMINATED MIRRORS TO BE @ 46 1/2" A.F.F. 3 G.C. (PROVIDE POWER & BLOCKING AS REQ'D.)
11
14 8. MIRROR IN ADA FITTING ROOM FURNISHED AND INSTALLED BY G.C. FITTING ROOM CABIN HANGING RAIL WITH HOOKS. FURNISHED BY H&M AND INSTALLED BY G.C.
ARCHITECT
7 4
9. FITTING ROOM MIRROR-LIGHTS TO CONTAIN INTEGRAL MOTION SENSORS (TYP.) E.C. TO RUN WIRE/
2'-6"
12 (SIM.) 5 FITTING ROOM CABIN HANGING RAIL. FURNISHED BY H&M AND INSTALLED BY G.C.
CABLING IN WALL CAVITY ADJACENT TO FITTING ROOM AND/OR TO JUNCTION BOX IN CEILING
EXISTING FITTING 11
ABOVE (TYP.) 572 NORTH BROADWAY
19 A-730 3 6 WALL MOUNTED MIRROR FURNISHED AND INSTALLED BY G.C. (U.S. MIRROR @ 8" AFF)
ROOM AREA #1 10. CLEAR SPACE MUST BE MAINTAINED.

EX. F.R. CUBICLE


A730 A730 WHITE PLAINS, NEW YORK 10603
127 7 "BACK" MIRROR (U.S. MIRROR @ 1'-6" AFF), FURNISHED BY H&M AND INSTALLED BY G.C.
FITTING ROOM PLAN (TYP.) 2 ADA-FITTING ROOM PLAN 3 TYP. 12 10 A-730 8 11. ALL MIRRORS TO BE ATTACHED PER H&M STORE INSTRUCTION REQUIREMENTS.

8'-1"±
12. ALL CABIN WALL AND BASE FINISHES TO REMAIN 'AS-IS'. EXCEPT WHERE PATCHING IS REQUIRED
SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" (PROVIDE FINISHES TO MATCH EXISTING) 8 HOOKS INSTALLED BY G.C (REFER TO ELEVATIONS FOR MOUNTING HT.) TEL 914 289 0011
9
9 HANGING BAR (REFER TO ELEVATION FOR MOUNTING HT.)

FITTING ROOM SCOPE 10 SEAT ( STOOL ). SUPPLIED AND INSTALLED BY H&M.


· EXISTING FITTING ROOM CABINS TO REMAIN AND RECEIVE NEW INTERIOR FITTINGS 11 POSTER CHANNEL PER H&M SPECIFICATIONS - SEE IPS DRAWING FOR ADDTL. INFO.
1'-0" PACKAGE. PATCH / REPAIR / PAINT DAMAGED WALLS AS REQD. (TO MATCH
PT-4 PT-4 HOOK FOR FITTING ROOM TAG (4'-0" AFF TO CENTERLINE) (SEE F.R. PLAN FOR LOCATIONS). G.C TO
CL EXISTING). WALLS ABOVE THE CABIN TO BE PAINTED 'LIGHT BEIGE' (PT-4) SEE FINISH 12 INSTALL IF NOT EXISTING AND REPLACED TO MATCH IF DAMAGED.
13 5'-0"±
EX. F.R. CUBICLE PLAN. EXISTING FITTING ROOM SIGN (FITTING ROOM #) REPAIR AND/OR REPLACE AS REQUIRED. (SEE F.R.
13 PLAN FOR LOCATIONS). G.C TO INSTALL IF NOT EXISTING AND REPLACED TO MATCH IF DAMAGED.
· REMOVE EXISTING CABIN CURTAIN AND ROD AND REPLACE WITH NEW DOOR
12
15
FITTING ROOM AREA #1 PLAN 1 PACKAGE, SUPPLIED AND INSTALLED BY G.C. COORDINATE WITH H&M PROJ. MGR. 14
A.D.A BENCH ( 20" x 42" ) TO BE FLOOR SUPPORTED & FASTENED TO FLOOR. PROVIDED BY OWNER &
SEE RCP

SEE RCP
INSTALLED BY G.C.
EXISTING CABIN

EXISTING CABIN
CL SCALE: 1/4" = 1'-0"
5 4 14 · INSTALL NEW 'WHITE ASH' PANELS WITH 'LIGHT BEIGE' STUCCO ABOVE AT ENTRY / 15 42" A.D.A GRAB BAR (2'-10" AFF TO CENTERLINE)
MIRROR

RORRIM
SERVICE AREA - SEE PLAN THIS SHEET.
6'-0"

6'-0"
7 7 16 FITTING ROOM GARMENT RETURN RACKS. SUPPLIED AND INSTALLED BY H&M.
· EXISTING CEILING AND LIGHTING TO REMAIN 'AS-IS' UNLESS OTHERWISE NOTED.
5'-3"

5'-3"
6 6 PATCHED AND REPAIRED AS REQUIRED AND PAINTED 'WHITE' (PT-1) 17 PANEL ABOVE DOOR TO MATCH DOOR FITTING ROOM PANELS

· EXISTING FLOORING TO REMAIN - PATCH, REPAIR AND CLEAN THROUGHOUT.

1'-6"
1'-6"

18 FITTING ROOM SERVICE DESK. SUPPLIED BY H&M AND INSTALLED BY G.C.


10"
10"

· SEE CONSTRUCTION / FINISH PLANS FOR ADDITIONAL INFO.


7" EX-BASE EX-BASE 19 FITTING ROOM BENCH. SPECIFICATIONS BY H&M STORE DESIGNER AND PURCHASED BY H&M.
CL CL
TYP. TYP. 4'-6" LIC # AR0015561
SEE FINISH PLAN - A511 FOR ADDITIONAL INFO 20 AREA OF FITTING ROOM WALLS TO RECEIVE FINISHED PANELS/ PAINT FINISH. SEE FINISH PLAN FOR
ADDITIONAL INFO.
FITTING ROOM ELEV. (TYP.) 4 ADA-FITTING ROOM ELEV. 8
SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" CAP TO MATCH AND ALIGN
WITH EXISTING FITTING ROOM
PARTITION WALL

(7'-10")
SEE PLAN
G.C. NOTE:
EXISTING FITTING ROOM PARTITIONS ARE NEW FITTING ROOM WALL
PANEL (FURNISHED BY H&M) WIDTH TO MATCH AND ALIGN
EXISTING AND BE RETRO-FIT WITH NEW CABIN TO BE ATTACHED TO SOLID WITH EXISTING FITTING ROOM
CORE WOOD FRAME PARTITION
DOORS. G.C. TO VERIFY EXISTING DIMENSION
PT-4 PT-4 & CONSTRUCTION TYPE FOR PROPER
INSTALLATION OF WOOD DOOR AND FRAME. EXP. 2/28/2025
EQ. EQ.
4" 4" 7 9
WALL PANEL ATTACHED TO REVISION:
SEE RCP
EXISTING CABIN

WOOD DOOR FRAME


BACK MIRROR

3 15 12
NON-COMBUSTIBLE F.R.T.

ALIGN

ALIGN
6'-0"

WOOD FRAME PAINTED TO


LC
4'-4"

6 MATCH EXISTING PARTITIONS


CL 3'-8" CL
10 F.R.T. WOOD BLOCKING WITH
4'-0"
TYP.

RUBBER DOOR STOP PADS


2'-10"

2'-10"

SOLID CORE WOOD DOOR


1'-6"

1'-6"

MIRROR
10"

FITTING ROOM
CABIN NOTE:
EX-BASE 14 EX-BASE G.C TO VERIFY IN FIELD FITTING
TYP. TYP. ROOM PARTITION WIDTH AND
CONSTRUCTION TYPE

FITTING ROOM ELEV. (TYP.) 5 ADA-FITTING ROOM ELEV. 9 HEADER


ISSUE DATE:
SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0"
06.12.23 FOR REVIEW & APPROVALS
SEE PLAN 07.17.23 FOR BIDS & PERMITS
FOR REFERENCE ONLY DOORS AND FRAMES TO BE SUPPLIED AND INSTALLED BY G.C. COORDINATE
INSTALLATION WITH H&M PROJ. MGR. PRIOR TO PURCHASE / INSTALL.
STEEL SUPPORT ANGLE AT BOTTOM
OF JAMB BETWEEN F.R. PANELS
BOLTED TO FLOOR
RETROFIT CABIN DOOR DETAIL (ON-SITE CONSTRUCTION) 18 LEVER SET; 'VIZILOK' HEAVY DUTY
ADA DOOR PRIVACY LOCK WITH
OCCUPANCY INDICATOR. (OR
PT-4 PT-4 NOT TO SCALE APPROVED EQUAL).
13 POSTER CHANNEL - NON-COMBUSTIBLE F.R.T.
VERIFY & COORD. EQ. 5'-3" EQ. WOOD FRAME BUILD-OUT
EQ. EQ. 5 PAINTED TO MATCH EXISTING
WITH H&M PROJ. POSTER CHANNEL SC-1
CL CL 12 TYP. FITTING ROOM CABINS (TYP.
MGR. BOTH SIDES

LIGHT BEIGE
2
SEE RCP

SEE RCP
EXISTING CABIN

EXISTING CABIN

STUCCO
CL LC

2'-4"
4 14 11 SOLID CORE WOOD DOOR
WITH 1" UNDER-CUT
ARCH PROJECT NO.: 10835
6'-0"

6'-0"

2024

VARIES

VARIES
PRODUCT SEASON:
A3 A3
5'-3"

5'-3"

SPACE NO.: 185


6 6
POSTER CHANNEL

DRAWN BY: JTA

WHITE ASH PANEL


SEE RCP

ALIGN ALIGN
1'-6"

1'-6"

20 SCALE: AS NOTED
10"

10"

(30" W.)
8'-4"

(1-1/2 PAIR) HINGES:

7'-10"
EXISTING FITTING ROOM PARTITION STANLEY, #FBB191, US26D EXISTING FITTING ROOM PARTITION
EX-BASE EX-BASE
TYP. TYP. DASHED LINE OF DOOR SWING
SERVICE POSITIONS FITTING ROOM SHEET TITLE:
FITTING ROOM ELEV. (TYP.) 6 ADA-FITTING ROOM ELEV. 10 18
DESK
(behind)
CABIN
FITTING ROOM AREA
SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" JAMB ENLARGED PLANS
AND ELEVATIONS
FITTING ROOM ELEV. @ SERVICE AREA 17 FITTING ROOM ELEV. @ SERVICE AREA 19
SEE PLAN
SEE PLAN SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0"

THE MALL AT WELLINGTON GREEN


PT-4 SC-1 SC-1
TYP. TYP.

STORE NO. US 326 - RED MOD

BLVD.WELLINGTON, FL. 33414


LIGHT BEIGE
LIGHT BEIGE

OPEN FITTING ROOM INTERIOR PLACEMENT - MIRROR ASSEMBLY


2'-4 1/4"

PT-4 13

STUCCO
STUCCO

2'-4"
STANDARD & ACCESSIBLE

10300 W. FOREST HILL


EQ. EQ. PROVIDED BY LOCAL CONTRACTOR: PROVIDED BY H&M:
EXISTING CABIN OPENING

2 4" 4" NOTE ON SITE: - SUITABLE SCREWS AND WALL PLUGS FOR FITTING - MIRROR FRAME
- MIRROR WALLMOUNT
SEE RCP

SEE RCP

FOR THIS APPLICATION ALL FITTING ROOMS TO WALLMOUNTS TO WALL. - LEAD FREE SAFETY MIRROR
EXISTING CABIN

HAVE WOMENS STYLE MIRROR ASSEMBLIES SEE

WHITE ASH PANEL


6MM THICK.
WHITE ASH PANEL

SEE RCP

SEE RCP
3
MIRROR

17 REFERENCE PICTURES BELOW:

2024
- GLUE.
6'-0"

F.R. ENTRY
4'-4"

(30" W.)

6 FITTING ROOM NOTE:


7'-10"

7'-10"
7'-10"

FITTING ROOM
ENTRY BEYOND ENTRY BEYOND Adhere to H&M sustainability requirements, including fair and equal
10 policies. For more info please see Procurement Handbook 2020.
7
SERVICE
1'-6"

1'-6"

MIRROR Locking Clips


DESK
10"

EX-BASE EX-BASE 1 2 3
TYP. TYP. 12
20 18 20 17

FITTING ROOM ELEV. (TYP.) 7 ADA-FITTING ROOM ELEV. 11 FITTING ROOM ELEV. @ SERVICE AREA 15 FITTING ROOM ELEV. @ SERVICE AREA 16
G.C. TO PROVIDE 12" x 12"
SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0"
CUTOUT WITH ACCESS PANEL IN
CAVITY BEHIND MIRROR AT
FITTING ROOM MIRROR CENTER OF WALL MOUNT FOR SHEET NO:
17 PT-1 12 13 SC-1 SC-1 276062-02 FS,F.ROOM,MIRROR,W750xH1850,ARC,SS
TYP. TYP. LED LIGHT BALLAST ([1]

A-730
TYP. TYP.
LIGHT BEIGE

BALLAST PER [3] CABINS).


LIGHT BEIGE
2'-2 3/4"

STUCCO

STUCCO
2'-4"

PT-4 ALIGN PT-4 PT-3 PT-4 PT-3

REV. NO:
EXISTING CABINS
SEE RCP

SEE RCP

WHITE ASH PANEL

WHITE ASH PANEL


SEE RCP

SEE RCP

NOT USED
STOCK RM.

STOCK RM.

7'-11 1/4"
F.R. ENTRY

F.R. ENTRY
EXISTING

EXISTING

(30" W.)

(30" W.)

16 U.O.N.

330
7'-10"

7'-10"
6'-8"
TYP.

NOTE:

250
SERVICE Locking clips MUST be
DESK used on mounted
FLOOR mirror glass!
D.O.B. NO:
MB-1 MB-1 MB-1 STEP 1: STEP 2: STEP 3:
TYP. 2 1 TYP. 20 17 18 2A 2 20 TYP. - Attach lead free safety glass - Hang assembled mirror on wall
- Fix wallmount on the center of
TYP. TYP. the wall 330mm from floor. mirror to provided wood backing mount.
- This distance is the same for using glue AND locking clips.
FITTING ROOM ELEV. @ CABINS 12 FITTING ROOM ELEV. @ SERVICE AREA 13 FITTING ROOM ELEV. @ SERVICE AREA 14 mens and ladies fitting rooms.

SCALE: 1/4" = 1'-0" NEW DOORS SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0"
JEFFREY
TAYLOR
ARCHITECT

572 NORTH BROADWAY


WHITE PLAINS, NEW YORK 10603

TEL 914 289 0011

LIC # AR0015561

EXP. 2/28/2025

REVISION:

NOTE:
G.C. TO PROVIDE (3) IN-CABIN ROUND
COMMERCIAL RECYCLE BINS FOR CABINET;
RUBBERMAID 'BRUTE' MOD. #H2175BLU 20 MATERIALS & HARDWARE LEGEND
GALLON, 23" H. X 19' DIA., COLOR: BLUE
OR APPROVED EQUAL ITEM DESCRIPTION
ISSUE DATE:
6'-0" PLAM-1 FORMICA LAMINATE #459-58, BRITE WHITE MATTE FINISH
06.12.23 FOR REVIEW & APPROVALS
2'-0" 2'-0" 2'-0" 3" X 6" CERAMIC TILE #0790 ARTIC WHITE, RITTENHOUSE SQUARE BY 07.17.23 FOR BIDS & PERMITS
WT-1 DALTILE IN RUNNING BOND PATTERN. GROUT: MAPEI - COLOR #38
AVALANCHE
1'-11" 1'-11" 1'-11"
INTERIOR CLEAR INTERIOR CLEAR INTERIOR CLEAR COR-1 1" CORIAN - "DOVE"

CABINET PULLS SUGATSUNE SATIN STL. ST. PULLS - 27 SERIES MODEL #27096

HAFELE "ACCURIDE 3834SC" # 422.86.951 w/ AUTOMATIC CLOSING


DRAWER SLIDE
HARDWARE
LINE OF SUPPORT

EQ.
BELOW S.S. HANDLE HAFELE #117.05.600 (OPTION FOR CABINET PULLS)
CONCEALED HINGE HAFELE MODEL: C2PFA99 # 329.07.609 ARCH PROJECT NO.: 10835

2'-3"
CL SHELF CLIP HAFELE # 282.22.013 PRODUCT SEASON: 2024
PANEL FASTENER KEKU PUSH-IN PANEL - HAFELE # 262.50.313 SPACE NO.: 185

EQ.
10"Ø OPENING
DRAWN BY: JTA
(TYP. OF 3) CABINET & HARDWARE GENERAL NOTES: SCALE: AS NOTED
1'-0" 2'-0" 2'-0" 1'-0" 1. DRAWER SLIDES TO BE RATED FOR 100 LBF & SHALL BE FULL EXTENSION, SIDE MOUNTED, ZINC
PLATED STEEL DRAWER SLIDES WITH STEEL BALL BEARINGS, BHMA A156.9, B05091.
CL CL CL 2. PROVIDE 2"X2" STEEL TUBES BELOW COUNTERTOPS WHERE SHOWN OR REQUIRED FOR SHEET TITLE:
EQUIPMENT ABOVE
3. ALL EXPOSED HARDWARE SHALL BE NO. 640 FINISHED.
4. FRAMELESS CONCEALED HINGES (EUROPEAN TYPE): BHMA A156.9, B01602, SELF-CLOSING
B.O.H MILLWORK
5. ADJUSTABLE SHELF STANDARDS & SUPPORTS: BHMA A156.9, B04071: WITH SELF RESTS, B04081 DETAILS AND ELEVATIONS
6. PROVIDE STAINLESS STEEL PINS FOR ALL ADJUSTABLE SHELVING

RECYCLING CENTER PLAN 1

THE MALL AT WELLINGTON GREEN


SCALE: 3/4" = 1'-0"

STORE NO. US 326 - RED MOD

BLVD.WELLINGTON, FL. 33414


10300 W. FOREST HILL
COR-1
COUNTERTOP

1/4" REVEAL. PAINTED WALL


OR METAL

2024
HEIGHT TO
MATCH OTHER DIVIDER PANEL
1 3 (SEE PLAN)
DRAWERS IN
A-741 A-741 2'-3"
LOUNGE
6'-0"
812" 10" Ø 812"
2'-0" 2'-0" 2'-0"
COR-1
COUNTERTOP

1"
1"
3/4"
PLAM-1

5"

5"
(SEE CONSTRUCTION PLAN)
3-5/8" 20GA MTL. STUDS

ALIGN
2'-10"
DOOR &

2'-1"
HARDWARE TO

2'-6"
MATCH KITCHEN
CABINET DOORS SHEET NO:
EQ. 1 EQ. 1 EQ. 1
PLAM-1

A-741

3"

3"
3"
PLAM-1

REV. NO:

D.O.B. NO:

RECYCLING CENTER ELEVATION 2 RECYCLING CENTER SECTION 3


SCALE: 3/4" = 1'-0" SCALE: 3/4" = 1'-0"
NOTE:
G.C. TO PROVIDE F.R. BLOCKING
ABOVE CEILING AT ALL AREAS OF
CURTAIN LENGTHS FIXTURE CEILING SUPPORT. PATCH &
ROOM DIVIDER CURVED SHEET - INSTALLATION REPAIR CEILING AS REQD. G.C. ATTACH METAL SUPPORT TUBES
NOTE ON SITE:
- The recommended distance between the
PROVIDED BY LOCAL CONTRACTOR:
- Attachment fittings needed to attach the ceiling
L: 3000mm
324035-01
L: 3000mm
122834-01
L: 3000mm
284929-01
TO DECK OR STRUCTURE ABOVE (TUBE
CANNOT BE SECURED TO CEILING).
JEFFREY
attachment points is max. 1000 mm.
- Position of curtain track according to
bracket to the ceiling.
- Tools. 3
TUBES TO BE 3'-3 1/2" O/C MAX.
SUPPORT TUBES SUPPLIED AND TAYLOR
layout and architectual details. INSTALLED BY G.C.
METAL TUBE WITH 1 1/4" X
PROVIDED BY H&M: 1 FRONT 1 1/4" METAL PLATE ENDS CURTAIN TRACK BRACKET FURNISHED ARCHITECT
- Curtain rail set 20 BY G.C. PAINTED PT-1. BY H&M AND INSTALLED BY G.C.
FOR USE WITH FOR USE WITH FOR USE WITH 30
- Curtain 282021-03 Light Pink Voile 282022-09 Light Pink Voile 282024-09 Light Pink Voile CURTAIN FURNISHED BY H&M AND
CEILING W: 3000mm H: 2800mm W: 3000mm H: 3000mm W: 3000mm H: 4500mm INSTALLED BY G.C.
572 NORTH BROADWAY
282023-07 Light Pink Voile 282025-03 Light Pink Voile CURTAIN TRACK FURNISHED BY
W: 3000mm H: 3500mm W: 3000mm H: 7000mm H&M AND INSTALLED BY G.C. G.C.
WHITE PLAINS, NEW YORK 10603
Curtain rail 282026-03 Light Pink Voile
TO CUT TRACK ON-SITE AS
(Example type) W: 3000mm H: 10000mm 2 REQUIRED.
COORDINATE & MODIFY CURTAIN LENGTH IN FIELD

TEL 914 289 0011


NOTE:
Drill hole depending on
ceiling height.

NOT USED
4'-0" - 5'-0"
CURTAIN TRACK BRACKET
FURNISHED BY H&M AND
CURTAIN

INSTALLED BY G.C.

PAN HEAD SCREWS AND


ANY REQUIRED FIXINGS
FURNISHED BY G.C.

ALWAYS ENSURE
6" 6" FINISHED END CAP AT
EXPOSED ENDS THIS FACE OF CURTAIN TRACK FACE TOWARD:
NOTE! NOTE!
1. STOREFRONT GLAZING (WHEN @ STOREFRONT WINDOW)
NOTE:
2. SALES AREA (WHEN @ WALL)
FRONT In the case where two horizontal rails
meet, the holding bracket should be 3. FRONT OF STORE OR PORTAL ( WHEN @ ROOM DIVIDERS)
2" - 4" used to cover both cut ends.
FLOOR LIC # AR0015561

STEP 1: STEP 2: NOTE:


- Attach rails to ceiling according to separate - Hang curtains on rail and distribute evenly across the rail - Hang curtains in windows where the ceiling is clearly visible STEP 1: STEP 2: STEP 3:
instructions. length. from the outside with the right side facing the facade - Attach floor and ceiling brackets in appropriate places. - Cut vertical tube and drill a hole through tube where it will - Cut horizontal tubes according to horizontal spacing
- Measure height from floor to curtain rail. - One curtain is 3000mm wide and covers 1200-1500mm of (see examples in pictures above). Make sure correct side of the bracket is facing forwards. be attached to ceiling bracket. between mounts. Note that the horizontal tubes pertrude
- Let tailor correct the curtains length to leave a wall width. - If needed extension tubes can be used for extra high - Mount to floor and ceiling brackets using provided secrews 150mm on each side of last vertical tubes.
gap of 50-100mm to floor. ceiling heights. and nuts. - Attach horizontal rails using the holder brackets and
screws.

CURTAIN RAIL CEILING MOUNTED- INSTALLATION V.2


FOR REFERENCE ONLY
VERIFY ALL MOUNTING REQUIREMENTS WITH H&M PROJECT MANAGER
NOTE ON SITE: PROVIDED BY LOCAL CONTRACTOR: PROVIDED BY H&M:
- The recommended distance between the - All attachment fixings needed to fit the ceiling - Curtain tracks set incl. ceiling brackets, gliders and end cap. ROOM CURTAIN DIVIDER CURVED DETAIL 3 EXP. 2/28/2025
attachment points is max. 1000 mm. If the brackets to the ceiling. - Curtains
SCALE: 1 1/2" = 1'-0"
curtain is heavier, extra holders are
ROOM DIVIDER CURVED SHEET - INSTALLATION (WHERE ADDITIONAL SUPPORT IS REQUIRED)
recommended where the curtain is parked if REVISION:
it is not stretched over the entire width of
the rail. INSTRUCTION VALID FOR PRODUCT:
- Position the curtain track according to 122834-01 CURTAIN RAIL,W.CEILING ATTACHMENTS,3000mm,WHITE CEILING
Architectual Details.
4 5 6

Ceiling
Attachment

Curtain
Rail

ISSUE DATE:
Mute 06.12.23 FOR REVIEW & APPROVALS
Strip
07.17.23 FOR BIDS & PERMITS
8'-6"

A 1 2 3
CEILING

Ceiling
Attachment
B Mute ARCH PROJECT NO.: 10835
Strip NOTE:
If corner is exposed. PRODUCT SEASON: 2024
Bend 15-25mm of
corner.
SPACE NO.: 185
Gliders
4" FLOOR
DRAWN BY: JTA
SCALE: AS NOTED
STEP 1: STEP 2: STEP 3:
- Connect rails together by using the rail connector. - Measure spacing and drill holes in the ceiling. Use appropriate - Slide in mute strip.
- Mount ceiling attachemts to rail with appropriate plugs to attach the ceiling brackets and rail to ceiling. - Add gliders. SHEET TITLE:
spacing. - Add end caps. STEP 4: STEP 5: STEP 6:
- Repeat Step 1 and 2 if needed.
- If end of room divider is in an exposed location, make sure - Attach perforated sheets to horizontal tubes using self - Make sure end of sheet overlap flush.
to bend corner of bottom sheet prior to assembly. drilling screws or rivets 100mm from floor. - If not, use rivet to secure sheets together. MISC DETAILS
NOTE: - Bend should be between 15 and 25 mm. - Make sure to minimize the amount of overlap beteen the
G.C. TO PROVIDE F.R. BLOCKING two sheets and the amount of rivets/screws used.
ABOVE CEILING AT ALL AREAS OF
FIXTURE CEILING SUPPORT. PATCH &
REPAIR CEILING AS REQD.

THE MALL AT WELLINGTON GREEN


ROOM DIVIDER CURVED SHEET

STORE NO. US 326 - RED MOD

BLVD.WELLINGTON, FL. 33414


CURTAIN RAIL FOR CURTAINS 4500MM OR LONGER- INSTALLATION
NOTE ON SITE:
NOTE ON SITE: PROVIDED BY LOCAL CONTRACTOR: PROVIDED BY H&M: - Make sure that the ceiling and floor mounts are vertically

10300 W. FOREST HILL


- The recommended distance between the - All attachment fixings needed to fit the ceiling - Curtain rails aligned (see floor plan for placement).
attachment points is max. 2000 mm. brackets to the ceiling. - Ceiling attachments
- Position the curtain rail according to the - Stoppers/End caps PROVIDED BY LOCAL CONTRACTOR:
architectual details. - Roll gliders - Screws and plugs used for attaching ceiling and floor
10 brackets.

2024
L: 3000mm
284929-01 PROVIDED BY H&M:
- See parts list below
20
80 30
INSTRUCTION VALID FOR PRODUCT:
329434-01 A R.DIV CURVE SHEETS,FRAME,1 SEC,CR.WH
329430-01 A R.DIV CURVE SHEETS,1064x33x2600,CR.WH
329429-01 A R.DIV CURVE SHEETS,532x33x2600.CR.WH
325044-01 B R.DIV CURVE SHEETS,EXTENSION TUBE,CR.WH

1 2 End cap

70

Ceiling Attachment 4 SHEET NO:


Ceiling Attachment

Rail

40 60 50
A-750
REV. NO:
Glider

FOR REFERENCE ONLY FOR REFERENCE ONLY D.O.B. NO:


VERIFY ALL MOUNTING REQUIREMENTS WITH H&M PROJECT MANAGER VERIFY ALL MOUNTING REQUIREMENTS WITH H&M PROJECT MANAGER

STOREFRONT CURTAIN & RAIL DETAILS 1 ROOM DIVIDER CURVED SHEET DETAIL 2
SCALE: 1 1/2" = 1'-0" SCALE: 1 1/2" = 1'-0"
NOTE:
ELECTRICAL ABBREVIATIONS ELECTRICAL SYMBOL LEGEND GENERAL NOTES IT IS THE ELECTRICAL CONTRACTOR'S RESPONSIBILITY TO
PROPERLY BALANCE ALL BRANCH CIRCUITS BETWEEN THE
SYMBOL DESCRIPTION SYMBOL DESCRIPTION PHASES OF THE SYSTEM, REGARDLESS OF THE CIRCUIT
1. FINAL CONNECTIONS TO ALL LAY-IN FIXTURES AND RECESSED INDICATED.
INCANDESCENT FIXTURES IN LAY-IN CEILINGS ARE TO BE MADE
A ------------- AMPS WITH GREENFIELD FLEXIBLE CONDUIT.
CONDUIT WITH WIRING RUN CONCEALED IN OR ABOVE CEILING OR
AC ------------ AIR CONDITIONING UNIT
WALL, OR RUN EXPOSED IN UNFINISHED AREAS. CROSS HATCHING THE ELECTRICAL CONTRACTOR SHALL VERIFY EXISTING
AFF ----------- ABOVE FINISH FLOOR 2. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT
INDICATES NUMBER OF CONDUCTORS (#12 A.W.G. - MINIMUM). CONDITIONS TO INSURE THAT THE NEW WORK WILL FIT TO THE
AFG ----------- ABOVE FINISH GRADE LOCATION OF SPEAKER AND LIGHT FIXTURE LAY-OUT.
PROVIDE A CODE-SIZED GROUND WIRE IN ALL CONDUITS IN EXISTING STRUCTURE IN THE MANNER INTENDED AND SHOWN
AHU ----------- AIR HANDLING UNIT ADDITION TO THE CONDUCTORS SHOWN. - CONTRACTORS TO CORRELATE LOCATIONS OF LIGHTING, ON THE DRAWINGS. SHOULD ANY CONDITIONS EXIST THAT ARE
AIC ------------ ASYMMETRICAL INTERRUPTING

ARCH.
CURRENT
---------- ARCHITECTURAL
INDICATES ADDITIONAL ISOLATED GROUND WIRE. SPEAKERS, AIR DIFFUSERS, GRILLES, AND THE LIKE, WITH
REFLECTED CEILING LAY-OUTS AS REQUIRED AND DIRECTED BY THE
CONTRARY TO THOSE ON THE DRAWINGS, THE CONTRACTOR
SHALL NOTIFY THE TENANT'S REPRESENTATIVE PRIOR TO
JEFFREY
CONDUIT WITH WIRING RUN CONCEALED BELOW FLOOR. CROSS ARCHITECT. FABRICATION OR PERFORMING ANY WORK IN THE AREA
ATS
AWG
BKR
----------- AUTOMATIC TRANSFER SWITCH
----------- AMERICAN WIRE GAGE
----------- BREAKER
HATCHING INDICATES NUMBER OF CONDUCTORS (#12 A.W.G. -
MINUMUM). PROVIDE A CODE-SIZED GROUND WIRE IN ALL CONDUITS 3. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN AND/OR ROOM
INVOLVING DIFFERENCES. NOTIFICATION SHALL BE IN THE
FORM OF A DRAWING OR SKETCH INDICATING FIELD
TAYLOR
BLDG. ---------- BUILDING IN ADDITION TO THE CONDUCTORS SHOWN. CUT AND PATCH FINISH SCHEDULE TO DETERMINE PROPER TYPE OF LIGHT FIXTURE MEASUREMENTS AND NOTES RELATED TO THE AREA.
C ------------- CONDUIT FLOOR AS REQUIRED. REQUIRED FOR THE CEILING CONSTRUCTION PRIOR TO ORDERING THE ARCHITECT
CATV ----------- CABLE TELEVISION FIXTURES AND SHALL PROVIDE FIXTURES THAT ARE COMPATIBLE
CCTV ----------- CLOSED CIRCUIT TELEVISION LIGHTING PANELBOARD MOUNTED 6'-6" TO TOP. SEE PANEL SCHEDULES WITH THE CEILING SYSTEM. ALL WIRING SHALL BE IN CONDUIT
CH ------------ CHILLER AND ELECTRICAL ONE-LINE DIAGRAM. E.M.T. OR RIGID
CONTR ---------- CONTRACTOR 4. ALL DEVICES, EQUIPMENT, FIXTURES, AND THE LIKE, MUST BE 572 NORTH BROADWAY
CT ------------ COOLING TOWER GROUNDED BY USE OF A PROPERLY SIZED GROUNDING CONDUCTOR. FLEXIBLE CONDUIT MAY ONLY BE USED FOR FINAL
CU ------------ COPPER SAFETY SWITCH - TYPE AND RATING AS SHOWN ON PLANS MECHANICAL/ ELECTRICAL BONDS OF THE METALLIC RACEWAY CONNECTIONS FROM OUTLET BOXES TO LIGHT FIXTURES, WHITE PLAINS, NEW YORK 10603
CUH ----------- CABINET UNIT HEATER SYSTEM SHALL ALSO BE MAINTAINED. MOTORS, APPLIANCES, ETC., MAX. LENGTH 6 FEET. NO BX,
DE ------------ DUAL ELEMENT ROMEX, ARMORED CABLE, ETC. ALLOWED.
SECURITY SYSTEM CONTACT TEL 914 289 0011
DN ------------ DOWN 5. REFER TO MECHANICAL, PLUMBING, AND FIRE PROTECTION PLANS THIS APPLIES TO ALL ELECTRICAL SYSTEMS, INCLUDING POWER,
DS ------------ DISCONNECT SWITCH 20A - 120V/277V SINGLE POLE TOGGLE SWITCH MOUNTED 44" AFF, FOR EXACT LOCATION OF MECHANICAL AND PLUMBING EQUIPMENT. LIGHTING, CONTROL, HVAC, SECURITY, DATA, PHONE, ETC.
DWG. ----------- DRAWING UNLESS NOTED OTHERWISE (WHRE INDICATED - SUBSCRIPT "3" COORDINATE LOCATION OF DISCONNECT SWITCH ASSOCIATED WITH
(E) or EXIST. ------ EXISTING S DENOTES 3 WAY SWITCH AND SUBSCRIPT "M" DENOTES MANUAL EACH PIECE OF EQUIPMENT WITH RESPECTIVE CONTRACTOR AND
EB ------------ ELECTRIC BASEBOARD MOTOR STARTER) INSTALL IN ACCORDANCE WITH THE NEC.
E.C. ----------- ELECTRICAL CONTRACTOR
EF
EH
------------ EXHAUST FAN
------------ ELECTRIC HEATER
20A-2P-3W-125V GROUNDING TYPE DUPLEX RECEPTACLE MOUNTED 6. REFER TO DIV. 15 (21, 22 & 23) SPECIFICATIONS, HVAC PLANS,
OC
OCCUPANCY SENSOR NOTES
18" A.F.F., U.O.N. FINISH COLOR TO MATCH ARCHITECTURAL FINISH. PLUMBING AND FIRE PROTECTION PLANS FOR ADDITIONAL
ELEC. ---------- ELECTRICAL 1. DUAL TECHNOLOGY OCCUPANCY SENSOR SHALL BE A
ELECTRICAL WORK AND REQUIREMENTS AND COORDINATION.
EM ------------ EMERGENCY 20A-2P-3W-125V GROUNDING TYPE DOUBLE DUPLEX RECEPTACLE WALL OR CEILING MOUNTED 24V D.C. UNIT AS INDICATED
EMT ----------- ELECTRICAL METALLIC TUBING MOUNTED 18" A.F.F. U.O.N. FINISH COLOR TO MATCH
EQ. 7. ALL RECEPTACLES SHOWN BACK-TO-BACK IN WALLS SHALL BE ON THE PLANS (TYPICALLY WATT STOPPER #DT-200 OR
------------ EQUAL ARCHITECTURAL FINISH. SEPARATED BY 8" MINIMUM. DT-300). SUBSCRIPT "C" DENOTES CEILING MOUNTED
ETR ----------- EXISTING TO REMAIN
EUH ----------- ELECTRIC UNIT HEATER IG
20A-2P-3W-125V ISOLATED GROUND TYPE DUPLEX RECEPTACLE DEVICE, SUBSCRIPT "W" INDICATES WALL MOUNTED
EWC ----------- ELECTRIC WATER COOLER MOUNTED 18" A.F.F. U.O.N. FINISH COLOR TO BE ORANGE UNLESS 8. WIRING IN PLENUMS SHALL BE PLENUM RATED. ALL WIRE SHALL BE DEVICE.
EWH ----------- ELECTRIC WATER HEATER DIRECTLY VISIBLE TO CUSTOMERS. IF DIRECTLY VISIBLE TO INSTALLED IN CONDUIT U.O.N. POWER PACKS SHALL BE CONNECTED AHEAD OF
2.
F ------------- FUSE CUSTOMERS, FINISH TO MATCH ARCHITECTURAL. SENSOR(S)/SWITCH(ES) ON A "NON-CONTROLLED" CIRCUIT
FA ------------ FIRE ALARM IG 20A-2P-3W-125V ISOLATED GROUND TYPE DOUBLE DUPLEX 9. BRANCH CIRCUIT WIRE SIZES (AND CONDUITS) SHALL BE INCREASED AND INSTALLED ABOVE ACCESSIBLE CEILING (TYPICALLY
FACP ---------- FIRE ALARM CONTROL PANEL RECEPTACLE MOUNTED 18" A.F.F. U.O.N. FINISH COLOR TO BE FROM THOSE INDICATED ON THE PLANS TO PREVENT EXCESSIVE WATT STOPPER "B SERIES").
FC ------------ FAN COIL UNIT ORANGE UNLESS DIRECTLY VISIBLE TO CUSTOMERS. IF DIRECTLY VOLTAGE DROP. BRANCH CIRCUITS SHALL BE INSTALLED WITH WIRES
FLUOR ---------- FLUORESCENT VISIBLE TO CUSTOMERS, FINISH TO MATCH ARCHITECTURAL. OF SUFFICIENT SIZE SO THAT VOLTAGE DROP BETWEEN THE PANEL 3. LINE VOLTAGE CONNECTIONS SHALL BE MADE IN A
FPB ----------- FAN POWER BOX (VAV) GFI
AND THE LOADS DOES NOT EXCEED A LIMIT OF 3%. JUNCTION BOX AT THE POWER PACK.
20A-2P-3W-125V GROUND FAULT CIRCUIT INTERRUPTING
F.P.C. ---------- FIRE PROTECTION CONTRACTOR
FS RECEPTACLE MOUNTED 48" A.F.F., UNLESS NOTED OTHERWISE. THE E.C. SHALL PROVIDE ALL REQUIRED DEVICES, POWER
------------ FLOW SWITCH 10. REGARDLESS OF THE TEMPERATURE RATING OF THE CONDUCTOR 4.
FT. ------------ FOOT/FEET FINISH TO MATCH ARCHITECTURAL FINISH. PACKS, WIRING, ETC. FOR A COMPLETE SYSTEM PER
INSULATION, ALL CONDUCTOR AMPACITY RATINGS FOR THIS PROJECT
G.C. ----------- GENERAL CONTRACTOR 20A-2P-3W-125V SPLIT (2-CIRCUIT) GROUNDING TYPE DUPLEX SHALL BE DETERMINED FROM THE 75°C CONDUCTOR TEMPERATURE MANUFACTURER'S SPECIFICATIONS. LIC # AR0015561
GFI ------------ GROUND FAULT INTERRUPTING RECEPTACLE MOUNTED AT 18" A.F.F., UNLESS NOTED OTHERWISE. RATINGS INDICATED IN THE NEC TABLES. WHERE EQUIPMENT OR
PROTECTION ONE CIRCUIT SHALL FEED TOP HALF AND ONE CIRCUIT SHALL FEED DEVICES ARE PROVIDED WITH TERMINALS/LUGS RATED FOR 60°C, THE 5. THESE WIRING DIAGRAMS ARE BASED ON WATT STOPPER.
GND ----------- GROUND BOTTOM HALF OF RECEPTACLE. AMPACITY RATING OF THE 75°C CONDUCTOR SHALL BE LIMITED TO ITS THE E.C. SHALL MEET THE REQUIREMENTS OF ANY
HID ----------- HIGH INTENSITY DISCHARGE ASSOCIATED 60°C RATING AS INDICATED IN THE NEC TABLES. THE ACCEPTABLE ALTERNATE MANUFACTURER TO PERFORM
J JUNCTION BOX - SIZE AS REQUIRED BY N.E.C.
HOA ----------- HAND-OFF-AUTOMATIC THE SAME FUNCTION.
ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE TO INCREASE THE
HP ------------ HORSEPOWER
CONDUCTORS AND CONDUIT SIZE AS REQUIRED.
HPS ----------- HIGH PRESSURE SODIUM XX INDICATES CODED NOTE
6. PROVIDE A 20A, 120V WALL SWITCH AT THE ROOM
HVAC ----------- HEATING, VENTILATION, AIR
11. ALL 120V AND 277V BRANCH CIRCUITS SHALL BE PROVIDED WITH ENTRANCE TO DISABLE THE OCCUPANCY SENSOR BY
CONDITIONING
IG DOORBELL PUSH BUTTON MTD. 48" A.F.F. SEPARATE NEUTRAL CONDUCTORS. SHARED NEUTRALS WILL NOT BE INTERRUPTING THE POWER PACK OUTPUT TO THE
------------ ISOLATED GROUND
INCAND. --------- INCANDESCENT PERMITTED FOR MULTI-CIRCUIT INSTALLATIONS. WHERE MULTIPLE LIGHTING CONTROLLER INPUT TERMINAL BOARD PER THE
JB ------------ JUNCTION BOX DOORBELL MTD. 84" A.F.F. U.O.N. CIRCUITS ARE RUN IN A COMMON RACEWAY, THE AMPACITY OF THE WATT STOPPER STANDARD CONTROL DETAILS.
B
KCMIL ---------- ONE THOUSAND CIRCULAR MILS CONDUCTORS SHALL BE PROPERLY DERATED & CONDUIT SHALL BE 7. THE POWER PACK BUILT-IN CONTACT SHALL BE WIRED TO
K.E.C. ---------- KITCHEN EQUIPMENT CONTRACTOR sM SIZED PER CODE. UNDER NO CIRCUMSTANCES SHALL MORE THAN SIX THE LIGHTING CONTROLLER INPUT TERMINAL BOARD,
KVA ----------- KILOVOLT AMPERE MANUAL MOTOR STARTER WITH SIZED OVERLOAD PROTECTION. (6) CURRENT CARRYING CONDUCTORS BE RUN IN A SINGLE CONDUIT. PROGRAMMED TO OPERATE THE CONTROLLABLE CIRCUIT
KW ------------ KILOWATT LIGHTING CONTROL TIME CLOCK REFERENCE NEC ARTICLE AND TABLE 310.15(B)(2)(a). BREAKER POWERING THE RESPECTIVE LIGHTING CIRCUIT.
LTG ----------- LIGHTING
EXP. 2/28/2025
LV ------------ LOW VOLTAGE sK 12. ALL CONDUITS SHALL CONTAIN A GROUND CONDUCTOR SIZED PER 8. INDIVIDUAL ROOM WALL OCCUPANCY SENSOR SWITCHES
MATV ----------- MASTER ANTENNA TV LIGHTING CONTROL OVERRIDE OR ROLLING GRILLE KEY SWITCH NEC TABLE #250.122. IN ADDITION, WHERE AN ISOLATED, INSULATED SHALL BE TYPE WATTSTOPPER PW-100. REVISION:
MAU ----------- MAKE-UP AIR UNIT GROUND IS REQUIRED, A SEPARATE GROUND CONDUCTOR WITH
MAX ----------- MAXIMUM OR SPEAKER, FLUSH MOUNTED AND FINISH TO MATCH GREEN INSULATION SHALL BE RUN FROM THE PANEL GROUND BUS TO
MCB ----------- MAIN CIRCUIT BREAKER P
ARCHITECTURAL FINISH U.O.N. THE ISOLATED GROUND CONNECTION OF THE DEVICE. IN NO CASE
MCC ----------- MOTOR CONTROL CENTER SHALL THE SYSTEM GROUND (CONDUCTOR & ASSOCIATED OUTLET
M.C. ----------- MECHANICAL CONTRACTOR "P" ADJACENT TO SYMBOL INDICATES PENDANT MOUNTED BOXES, CONDUIT & BUILDING STEEL) BE ALLOWED TO CONTACT THE
MECH. ---------- MECHANICAL ISOLATED GROUND (CONDUCTOR & DEVICE). WHERE CIRCUIT
MFR ----------- MANUFACTURER CONDUCTORS ARE INCREASED IN SIZE FOR VOLTAGE DROP, THE
MH ------------ METAL HALIDE COMMUNICATIONS OUTLET MOUNTED AT 18" A.F.F. U.O.N.
GROUND CONDUCTOR SIZE SHALL BE INCREASED PROPORTIONATELY
MIN ----------- MINIMUM 5(D) PROVIDE CONDUIT SIZED PER SPECIFICATION'S FILL
(ACCORDING TO CIRCULAR MIL AREA) FROM THE SIZE REQUIRED BY
MLO ----------- MAIN LUGS ONLY REQUIREMENTS (3/4" MINIMUM) TO DATA RACK IN LAN ROOM WITH
NEC TABLE #250.122.
MOD ----------- MOTOR OPERATED DAMPER CABLING PER SPECIFICATIONS. "W" ADJACENT TO SYMBOL
MSB ----------- MAIN SWITCHBOARD INDICATES WALL MOUNTED AT 48" A.F.F. REFER TO
MTD ----------- MOUNTED 13. ELECTRICAL INSTALLATION REQUIREMENTS FOR ALL HVAC, PLUMBING,
RESPONSIBILITY SCHEDULE SECTION 16740 LETTER(S) ADJACENT
NEC ----------- NATIONAL ELECTRIC CODE FIRE PROTECTION, SPECIAL SYSTEMS AND OWNER EQUIPMENT BEING
TO SYMBOL DEFINES THE USE OF THE OUTLET: D - DATA
NF ------------ NON FUSED FURNISHED BY OTHERS SHALL BE REVIEWED AND COORDINATED WITH
NFPA ---------- NATIONAL FIRE PROTECTION OTHER TRADES PRIOR TO ROUGH-IN. OBTAIN EQUIPMENT SHOP
ASSOCIATION DRAWINGS FROM INSTALLER/SUPPLIER/CONTRACTOR/OWNER
FURNISHING EQUIPMENT, AS REQUIRED, FOR REVIEW AND
ISSUE DATE:
NIC ------------ NOT IN CONTRACT
NUMBER ADJACENT TO SYMBOL DEFINES THE QUANTITY OF CABLES
NL ------------ NIGHTLIGHT COORDINATION. CONTACT ARCHITECT/ENGINEER WITH ANY 06.12.23 FOR REVIEW & APPROVALS
NTS ----------- NOT TO SCALE DISCREPANCIES FOUND BETWEEN CONSTRUCTION DRAWINGS AND
OCC ----------- OCCUPANCY EQUIPMENT BEING FURNISHED PRIOR TO ROUGH-IN. 07.17.23 FOR BIDS & PERMITS
Ø or P --------- PHASE SM,BM SILVER OR BRONZE MIRROR THE FULL HEIGHT AND WIDTH OF
PB ------------ PULL BOX THE COLUMN FROM FLOOR TO CEILING. IF A BASEBOARD IS 14. THE ELECTRICAL CONTRACTOR SHALL FURNISH ALL ACCESS PANELS,
P.C. ----------- PLUMBING CONTRACTOR PRESENT, THEN MIRROR HEIGHT IS FROM THE BASEBOARD TO AS REQUIRED FOR SERVICING AND TESTING, FOR EQUIPMENT AND/OR
PNL ----------- PANEL CEILING. FURNISHED AND INSTALLED BY OTHERS. DEVICES FURNISHED UNDER HIS CONTRACT. THE GENERAL
PRE ----------- POWER ROOF EXHAUSTER CONTRACTOR SHALL INSTALL ACCESS PANELS. THE ELECTRICAL
PVC ----------- POLYVINYL CHLORIDE MSFD MOTORIZED FIRE SMOKE DAMPER. REFER DETAIL BELOW FOR
CONTRACTOR SHALL COORDINATE THE SIZE AND LOCATION OF EACH
RE ------------ REMOVE EXISTING MORE INFORMATION IF APPLICABLE. COORDINATE WITH
ACCESS PANEL WITH THE ARCHITECT AND GENERAL CONTRACTOR
RR ------------ REMOVE AND RELOCATE MECHANICAL CONTRACTOR.
----------- ROOF TOP UNIT PRIOR TO ROUGH-IN.
RTU DOME CAMERA FURNISHED BY OTHERS, INSTALLED AND WIRED
SPKR ---------- SPEAKER
BY E.C. WIRE TYPE (RG59U TO DVR) 15. ELECTRICAL CONTRACTOR SHALL INCLUDE IN HIS BID ALL CUTTING,
SPST ----------- SINGLE POLE SINGLE THROW
------------ TIE CIRCUITS TOGETHER TRENCHING AND PATCHING ASSOCIATED WITH THE ELECTRICAL
TIE
INSTALLATION. ARCH PROJECT NO.: 10835
TS ------------ TAMPER SWITCH FIXED DOMED CAMERA FURNISHED BY OTHER, INSTALLED AND
TTB ----------- TELEPHONE TERMINAL BOARD WIRED BY E.C. WIRE TYPE (RG59U TO DVR) PRODUCT SEASON: 2024
TV ------------ TELEVISION 16. ALL PENETRATIONS THROUGH FIRE RATED WALLS ASSOCIATED WITH
TYP. ----------- TYPICAL THE ELECTRICAL INSTALLATION SHALL BE SLEEVED AND SPACE NO.: 185
WAVE 2 SIREN FURNISHED BY OTHER, INSTALLED AND WIRED BY FIRE-STOPPED USING A UL APPROVED METHOD. UL APPROVED
UH ------------ GAS FIRED UNIT HEATER
METHOD SHALL MEET OR EXCEED FIRE RATING OF STRUCTURE BEING
DRAWN BY: JTA
UL ------------ UNDERWRITER'S LABORATORY E.C. WIRE TYPE (18/4)
UON ----------- UNLESS OTHERWISE NOTED PENETRATED. REFERENCE ARCHITECTURAL PLANS FOR FIRE RATED SCALE: AS NOTED
UV ------------ UNIT VENTILATOR BACP BURGLAR ALARM CONTROL PANEL STRUCTURES.
V ------------- VOLTS
W ------------- WATTS GSM GSM RADIO 17. NO CONDUIT, BOXES, WIRING, OR CABLES SHALL BE INSTALLED WITHIN
WP ------------ WEATHERPROOF TYPE DEVICE 1 1/2" OF THE LOWEST POINT OF THE UNDERSIDE OF THE ROOF SHEET TITLE:
(NEMA 3R RATED) DECKING, NOR SHALL THEY BE INSTALLED CONCEALED WITHIN
KEYPAD. WIRE TYPE (18/4)
X'FMR ---------- TRANSFORMER METAL-CORRUGATED ROOF DECKING. FOR EXISTING INSTALLATIONS, ELECTRICAL LEGEND
THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE TO REPLACE
TRANSMITTER CONTACT (WIRELESS)
AND/OR REWORK EXISTING CONDUIT, BOXES, WIRING, AND CABLING AND NOTES
WIRELESS RECEIVER THAT IS NOT IN COMPLIANCE WITH THIS REQUIREMENT.

WALL MOUNT MOTION DETECTOR (WIRELESS) 18. ALL ELECTRICAL EQUIPMENT AND DEVICES FOR THIS PROJECT MUST
BE UL LISTED. DEVICES, EQUIPMENT, SYSTEMS SHALL BE INSTALLED
DVR CCTV DVR HEAD END UNIT PER N.E.C REQUIREMENTS AND MANUFACTURER'S INSTRUCTIONS.

CARD READER 19. ALL CONDUIT AND CABLING SHALL BE PROPERLY SUPPORTED AS
REQUIRED BY THE NATIONAL ELECTRICAL CODE. FOR EXISTING

THE MALL AT WELLINGTON GREEN


INSTALLATIONS, THE ELECTRICAL CONTRACTOR SHALL BE

STORE NO. US 326 - RED MOD


RESPONSIBLE TO REPLACE AND/OR REWORK EXISTING CONDUIT

BLVD.WELLINGTON, FL. 33414


AND/OR CABLING THAT IS NOT IN COMPLIANCE WITH THIS
REQUIREMENT.

10300 W. FOREST HILL


2024
SHEET NO:

A-760
REV. NO:

D.O.B. NO:
(TYPICAL AT
5
CASH WRAP)

LP2-34

LIGA-12
LIGA-39

LIGA-36
LP2-32
LP2-29

LP2-31
SPARE TO 6"

LIGA-10
LIGA-32

LIGA-6

LIGA-8
LIGA-4

LP2-4

LP2-6
LP2-6
LP2-2
ABOVE CLG.
PROVIDE 6 1
LIGA-40,42
4(D) IG IG 2(D)
PULL-STRING
LIGA-41 IG 4(D) IG IG 4(D) IG 4(D) IG ℄ OF C/W

5'-2"
1

5'-2"
LIGA-32
6'-87 8"

PROCESSING AREA
HOLIDAY
CASH WRAP
1A
2A 2 2A
HOLIDAY CASH
L L JEFFREY

6'-4 1/2"
1 1A
3 US WRAP ℄ OF C/W IG NEW ADJUSTABLE

1
3 3
HIDDEN LINE INDICATES
PROCESSING TABLE
TAYLOR
'RFID' PAIN 7
3 RFID
NEW FLOOR ARCHITECT

6'-4 1/2"
4 4 SPARE 3/4" 1A EXSP EXSP
CR 3
2 INSTALLATION ON WALL & MOUNTED DUPLEX
CONDUIT 2A (2) 1 1/4" CONDUITS F
DOOR INSTALLED PER P 2 LIGA-33 6'-9" OUTLET TO BE
FOR DATA, PROVIDE 4
3 END BUSHING ON MAUF. DIRECTION INSTALLED FLUSH
NOTE SEE FINISH PLAN FOR 5 WITH FLOOR FINISH
NO CONDUITS PENETRATIONS
CONDUIT RFID
A 572 NORTH BROADWAY
ADDITIONAL INFO.
THRU DEMISING WALL. LIGA-32 JB JB
LIGA-32 WHITE PLAINS, NEW YORK 10603
IG 3'-4" X 7'-0"
LP2-6,32 6
4 J
LIGA-1,3 LIGA-8,10 4 IG IG 4(D) 2(D) IG IG
LIGA-5,7
NEW
LIGA-6
LP2-2,4 LIGA-2,4
LIGA-12 LIGA-36,37 7 TEL 914 289 0011
EXISTING LP2-31
CONDUITS AND CIRCUITS LIGA-40 LIGA-42 6
6 CONDUITS AND NEW
PROVIDE TRENCHING AS LP2-17
CIRCUITS (SHOWN CONDUITS AND CIRCUITS JUNCTION BOX FOR
REQUIRED, PATCH / REPAIR ACCESS
7 LIGA-39,41 SHADED) - SHOWN PROVIDE TRENCHING AS CASHWRAP BRANCH
AND INSTALL NEW FLOOR TILE LP2-29 COVERPLATE
FOR REFERENCE REQUIRED, PATCH / REPAIR CIRCUIT ISO, GROUND
TO MATCH EXISTING. COORD.
ONLY AND INSTALL NEW FLOOR TILE POWER WIRING TRENCH
TRENCHING WITH MALL
TO MATCH EXISTING IN SLAB
MANAGEMENT.

ENLARGED CASHWRAP PLAN 1 ENLARGED CASHWRAP PLAN 2 ENLARGED 'CLICK & COLLECT' STOCK PLAN 3 ENLARGED 'VISUAL ROOM / STOCK PLAN 4
SCALE: NTS (ATEXISTINGCASHWRAPLOCATION-SEECONSTRUCTION/FIXTUREPLANS) SCALE: NTS (NEWCASHWRAPLOCATION-SEEFIXTUREPLAN) SCALE: NTS SCALE: NTS (EXISTINGNIGHTBOXLOCATION)

GENERAL NOTES GENERAL NOTES GENERAL NOTES


1. REFER TO ARCHITECTURAL PLANS FOR ADDITIONAL CONSTRUCTION INFO. 1. REFER TO ARCHITECTURAL PLANS FOR ADDITIONAL DEMO.
AND CASHWRAP DIMENSIONS.
ELECTRICAL SPECIFICATIONS 2. ELECTRIC CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING TEMPORARY
1. REFER TO ARCHITECTURAL PLANS FOR ADDITIONAL DEMO.
2. SEE FIXTURE PLAN FOR NEW ROOM CONFIGURATION. E.C. TO COORDINATE
Section 16740: Data Conduit Fill Requirements INSTALLATION OF NEW OUTLETS WITH G.C.
LIGHTING AND ELECTRIC DURING DEMOLITION AND CONSTRUCTION. E.C. TO 2. SEE FIXTURE PLAN FOR NEW ROOM CONFIGURATION. E.C. TO COORDINATE
DETERMINE EXACT SCOPE PRIOR TO FINALIZING BID. INSTALLATION OF NEW OUTLET WITH G.C.
INSIDE CABLE OUTSIDE DIAMETER mm (in) 3. EXISTING LIGHTING, SPRINKLERS, DIFFUSERS, AND CEILING MOUNTED
EQUIPMENT TO REMAIN 'AS-IS' 3. E.C. TO VISIT SITE AND FIELD DETERMINE EXACT SCOPE AND VERIFY ANY LIC # AR0015561
TRADE DIAMETER 3. EXISTING LIGHTING, SPRINKLERS, DIFFUSERS, AND CEILING MOUNTED
SIZE 3.3 4.6 5.6 6.1 7.4 7.9 9.4 13.5 15.8 17.8 ADDITIONAL EQUIPMENT, DEVICES, ETC. TO BE REMOVED AND / OR REQUIRED
(0.13) (0.18) (0.22) (0.24) (0.29) (0.31) (0.34) (0.53) (0.62) (0.70) 4. COORDINATE QUANTITY AND LOCATIONS OF ALL POWER AND DATA DEVICES EQUIPMENT TO REMAIN 'AS-IS'
In mm FOR PLAN DESIGN.
FOR INSTALLATION OF NEW CASHWRAP PER H&M STANDARDS.
1/2* .622 16 1 1 0 0 0 0 0 0 0 0 4. NOTIFY ARCHITECT OF ANY DISCREPANCIES OR CONCERNS THAT MIGHT
5. ALL FLOOR CONDUIT PENETRATIONS SHALL BE FIRE RATED OR FIRE STOPPED
AS REQUIRED BY THE LOCAL JURISDICTION AND / OR LANDLORD. AFFECT DESIGN SCOPE.
3/4 .824 21 6 5 4 3 2 2 1 0 0 0
6. ALL DATA AND I.G. RECEPTACLES SHALL BE INSTALLED IN LOCATIONS SHOWN. KEY NOTES #
1 1.049 27 8 8 7 6 3 3 2 1 0 0 I.G. RECEPTACLE CIRCUITS SHALL BE IN CONDUIT. DATA CABLING SHALL BE
RAN WITHOUT CONDUIT BELOW CASHWRAP ONLY. ALL HOMERUNS (DATA & I.G.
SHALL BE IN E.M.T. 1. PROVIDE POWER CONDUIT TRENCHED WITHIN FLOOR SLAB FOR NEW
1 1/4 1.380 35 16 14 12 10 6 4 3 1 1 1
FLOOR MOUNTED DUPLEX OUTLET. METHOD OF TRENCHING SHALL BE

1 1/2 1.610 41 20 18 16 15 7 6 4 2 1 1
7. ALL JACKS ARE ARBITRARILY LABELED AS DATA AND TELEPHONE USE THE
SAME JACKS. THE H&M I.T. REP, SHALL DETERMINE WHICH JACKS ARE FOR
KEY NOTES # PER BUILDING REQUIREMENTS. CONTRACTOR SHALL SIZE CONDUIT PER
DATA AND WHICH ARE FOR TELEPHONE (TYP.) NEC.
2 2.067 53 30 26 22 20 14 12 7 4 3 2 EXP. 2/28/2025
8. WALL OUTLETS AND FACEPLATES TO MATCH ADJACENT WALL FINISH. 1. EXISTING RECESSED LIGHTS TO BE RE-CIRCUITED AND INTERLOCKED WITH 2. EXISTING LIGHTING, SPRINKLERS, DIFFUSERS, AND CEILING MOUNTED
NEW WALL MOUNTED MOTION DETECTOR. EQUIPMENT TO REMAIN 'AS-IS'
2 1/2 2.469 63 45 40 36 30 17 14 12 6 3 3
REVISION:
2. PROVIDE 'YSHIELD' GS2 GROUNDING PLATE FOR RFID PAINT. PROVIDE #6
3 3.068 78 70 60 50 40 20 20 17 7 6 6 KEY NOTES # GROUND WIRE TO EXISTING GROUND BAR IN LAN ROOM. SEE FLOOR FINISH
1 EXISTING PLAN FOR EXACT RFID PAINT LOCATION AND INSTALL PER MANUF.
3 1/2 3.548 91 MAX MAX MAX MAX MAX MAX 22 12 7 6 1. PROVIDE (2), 1 1/4" DEDICATED CONDUITS WITH PULL WIRE FROM
INSTRUCTIONS. COORDINATE WITH H&M PROJ. MGR. DATA BACK TO LAN
1A NEW CASHWRAP UP TO 6" ABOVE ADJACENT CEILING FOR DATA CABLE. PROVIDE
ROOM. G.C. TO PROVIDE
4 4.026 103 MAX MAX MAX MAX MAX MAX 30 14 12 7 TELECOMMUNICATIONS CONDUIT WITHIN FLOOR OR WITHIN ACCESSIBLE 3. CR CARD READER - CARD READER TO BE RECESSED IN FRAME IN THE 2"x4" BOX CONDUIT AND
CEILING OF FLOOR BELOW, BETWEEN CASHWRAP, AND NEAREST WALL. WALL. PULL STRING
TYPICAL 2-PAIR CAT 3 CABLE LP2-17
METHOD OF CORE DRILLING, TRENCHING, ETC. SHALL BE PER BUILDING LV WIRING BY H&M
VENDOR
TYPICAL 4-PAIR CAT 3 CABLE REQUIREMENTS. COORDINATE EXACT REQUIREMENTS WITH H&M AND 4. WALL MOUNT MOTION DETECTOR. *
TYPICAL 4-PAIR CAT 5E CABLE ARCHITECT.
TYPICAL 4-PAIR CAT 6 (WITHOUT DIVIDER) CABLE 5. *PROVIDE A JUNCTION BOX FOR BURG MOTION SENSOR. VERIFY EXACT 2(D)
2 EXISTING 2. PROVIDE POWER CONDUIT WITHIN FLOOR OR WITHIN ACCESSIBLE CEILING LOCATION AND QUANTITY PRIOR TO BID.
TYPICAL 4-PAIR CAT 6 (WITH DIVIDER) OR 4-PAIR ScTP CABLE +87" +87"
2A NEW OF FLOOR BELOW, BETWEEN CASHWRAP, AND NEAREST WALL. METHOD OF AFF AFF
TYPICAL 12-PAIR CAT 3 UNSHIELDED CABLE 6. CEILING MOUNTED SMOKE DETECTOR.
EQ. EQ. ISSUE DATE:
CORE DRILLING, TRENCHING, ETC. SHALL BE PER BUILDING REQUIREMENTS.
TYPICAL 25-PAIR CAT 3 UNSHIELDED CABLE CONTRACTOR SHALL SIZE CONDUIT PER NEC. 06.12.23 FOR REVIEW & APPROVALS
7. FIRE ALARM STROBE (VISUAL) DEVICE.
TYPICAL 50-PAIR CAT 3 UNSHIELDED CABLE
07.17.23 FOR BIDS & PERMITS
3. CONDUIT STUB-UP LOCATION AT CASHWRAP MUST BE AT MILLWORK 8. EXSP EXISTING CONCEALED SPRINKLER HEAD TO REMAIN - ENSURE PROPER
TYPICAL 50-PAIR CAT 3 SHIELDED ARMM CABLE SECTION INDICATED. CANNOT STUB-UP AT CASH REGISTER BAYS. ROOM COVERAGE.
TYPICAL 100-PAIR CAT 3 UNSHIELDED CABLE
4. PROVIDE NEW AND / OR COORDINATE LOCATION OF SECURITY CAMERAS,
SOURCES: BICSI TDMM, GENERAL CABLE, SUPERIOR ESSEX

*NOTE: 1/2" CONDUIT SHALL NOT BE USED FOR THIS PROJECT FOR DATA CABLE.
AS REQD., COORDINATE WITH H&M PROJECT MANAGER AND H&M SECURITY
VENDOR.
DOOR SCHEDULE - DOOR ACCESS SYSTEM ENLARGED BOPIS LOCKERS 6
ARCH DR. DOOR ROOM ELECTRICAL REQUIREMENTS BY E.C.** SCALE: NTS
NUMBER SET *
5. CONTRACTOR SHALL INSTALL IG RECEPTACLE AND TEL / DATA DEVICE
'CLICK &
CLOSEST TO REGISTER PORTION OF OF THE CASH DESK (TYPICAL OF ALL
100 COLLECT"
CASH REGISTERS). COORDINATE FINAL LOCATION WITH H&M I.T. PRIOR TO (DWG. A800) A SHIP TO SEE DETAIL 'A' ARCH PROJECT NO.: 10835
START OF WORK. STORE BELOW FOR ADDITIONAL INFORMATION PRODUCT SEASON: 2024
STOCK RM
SPACE NO.: 185
6. PROVIDE CONDUIT WITH PULL WIRE FROM CASHWRAP BACK TO LAN ROOM
FOR DATA CABLE. REFER TO CONDUIT FILL REQUIREMENT CHARTS FOR DRAWN BY: JTA
CONDUIT SIZE ON THIS DRAWING. COORDINATE EXACT REQUIREMENTS SCALE: AS NOTED
WITH H&M I.T. AND ARCHITECT.

7. QUAD I.G. DEDICATED CIRCUIT(S) AND (3) DATA JACK MOUNTED 18" ABOVE SHEET TITLE:
FINISHED FLOOR FOR HOLIDAY ROLL- AWAY CASHWRAPS. E.C. SHALL
INSTALL RECEPTACLES FOR ALL ROLL- AWAY CASHWRAPS, RECEPTACLES ENLARGED MEP
TO BE LOCATED AT CONVENIENT LOCATION FOR ADDITIONAL CASHWRAPS. PLANS, DETAILS & NOTES
VERIFY LOCATIONS WITH H&M.
NOTE:
ALL WORK TO BE DONE PER LATEST H&M
GUIDELINE STANDARDS, 'HOW TO BUILDS'
12 x 10 (EXISTING) (EXISTING) 16 x 14 AND MANUFACTURERS INSTRUCTION.

THE MALL AT WELLINGTON GREEN


STORE NO. US 326 - RED MOD

BLVD.WELLINGTON, FL. 33414


(EXISTING)
GENERAL NOTES

10300 W. FOREST HILL


10"Ø 10"Ø 8"Ø 10"Ø 1. EXISTING CEILING TO BE REPAIRED TO MATCH AND ALIGN WITH EXISTING
(EXISTING) (EXISTING) (EXISTING)
AFTER INSTALLATION OF NEW BRANCH DUCT AND DIFFUSER.
1. ELECTRICAL CONTRACTOR SHALL HAVE AN ELECTRICIAN ON SITE 4 HOURS PRIOR TO OPENING
OF THE STORE ON OPENING DAY AND SHALL REMAIN ON SITE THROUGHOUT THE DAY IN
CD-1, 14"Ø CD-1, 14"Ø

2024
CD-1, 14"Ø ORDER TO TROUBLESHOOT AND CORRECT ANY ELECTRICAL ISSUES THAT MAY ARISE.
315 CFM 315 CFM 315 CFM
(EXISTING (EXISTING (EXISTING 2. ELECTRICAL CONTRACTOR SHALL HAVE AN ELECTRICIAN ON SITE 4 HOURS PRIOR TO THE
NO CHANGE) NO CHANGE) NO CHANGE) START OF THE PRESS PARTY AND SHALL REMAIN ON SITE THROUGHOUT THE EVENT IN ORDER
TO TROUBLESHOOT AND CORRECT ANY ELECTRICAL ISSUES THAT MAY ARISE.
MECHANICAL / HVAC KEY NOTES 3. ELECTRICAL CONTRACTOR SHALL HAVE AN ELECTRICIAN ON SITE DURING LIGHTSTAT/ESTAT
INSIDE OF STOCKROOM INSIDE OF SALES COMMISSIONING. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE TO CONTACT
LIGHTSTAT AND CONFIRM THE DATE FOR COMMISSIONING. REFER TO SPECIFICATION 16442 ON
1. INSTALL NEW DUCT BRANCH TIED INTO EXISTING AS SHOWN. THE E800 SERIES DRAWINGS FOR CONTACT INFORMATION.

2. ADD NEW DIFFUSER, CONNECT TO EXISTING SUPPLY AIR MAIN DUCT AND NOTE:
CD-2, 8"Ø 1
BALANCE AS SHOWN. CONDUIT MUST BE 1" WITH PULL STRING. CONDUIT TO EXTEND ABOVE CEILING
100 CFM WITH A PLASTIC CONDUIT BUSHING ON THE END. IF CONDUIT IS REQUIRED
3. EXISTING CONCEALED SPRINKLER HEADS TO REMAIN. THROUGHOUT THE FACILITY. CONDUIT FROM EACH DOOR HAS TO GO TO THE LAN THE ELECTRICAL CONTRACTOR SHALL VERIFY EXISTING CONDITIONS TO INSURE THAT THE NEW WORK WILL
ROOM AND INTO THE 4" X 4" TROUGH. LABEL EACH CONDUIT BY THE DOOR FIT TO THE EXISTING STRUCTURE IN THE MANNER INTENDED AND SHOWN ON THE DRAWINGS. SHOULD ANY
DESIGNATION SHOWN ON THE PLANS. ALL BOXES TO BE 4" X 4" STANDARD CONDITIONS EXIST THAT ARE CONTRARY TO THOSE ON THE DRAWINGS, THE CONTRACTOR SHALL NOTIFY
ELECTRICAL BOXES WITH SINGLE GANG MUD RING. ANY FAIL SAFE AREA MUST BE THE TENANT'S REPRESENTATIVE PRIOR TO FABRICATION OR PERFORMING ANY WORK IN THE AREA SHEET NO:

A-761
CONNECTED TO A FIRE RELAY PROVIDED BY FIRE ALARM VENDOR. INVOLVING DIFFERENCES. NOTIFICATION SHALL BE IN THE FORM OF A DRAWING OR SKETCH INDICATING
HVAC DIFFUSER SCHEDULE FIELD MEASUREMENTS AND NOTES RELATED TO THE AREA.
3 3
'TITUS' - MOD. NO. OMNI, LAY-IN 24" X 24", WHITE, 4 -WAY THROW SHIP TO STORE 'CLICK & COLLECT) STOCKROOM
CD-2
(TO MATCH EXISTING DIFFUSERS). A NO SCALE (E.M.T. OR RIGID)
ALL WIRING SHALL BE IN CONDUIT
2 FLEXIBLE CONDUIT MAY ONLY BE USED FOR FINAL CONNECTIONS FROM OUTLET BOXES TO LIGHT
3'-4" X 7'-0"
FIXTURES, MOTORS, APPLIANCES, ETC., MAX. LENGTH 6 FEET.
REV. NO:
NOTE:
SHOWN FOR REFERENCE AND BIDDING PURPOSES ONLY. REFER TO JOB SPECIFIC
SHOP DRAWINGS BEFORE INSTALLATION. E.C. IS RESPONSIBLE FOR ALL CONDUIT NOTE:
CLICK & COLLECT STOCK AND BACKBOXES IT IS THE ELECTRICAL CONTRACTOR'S RESPONSIBILITY TO PROPERLY BALANCE ALL BRANCH CIRCUITS
(NEWDIFFUSERPLAN) BETWEEN THE PHASES OF THE SYSTEM FOR EACH ZONE AND/OR CONTACTOR REGARDLESS OF CIRCUIT
INDICATED.

D.O.B. NO:
NOTE:
ROOM / CASHWRAP LAYOUTS & LOCATIONS SHOWN FOR BID PURPOSE AND DESIGN INTENT ONLY. E.C.
RESPONSIBLE FOR WORKING SPACE, CLEARANCES, AMD TRANSFORMER FEEDER LENGTHS PER N.E.C. AND
ENLARGED HVAC PLAN 5 SHIP TO STORE (CLICK & COLLECT) STOCKROOM DOOR DETAIL 5 LOCAL CODE.

SCALE: NTS SCALE: NTS


JEFFREY
TAYLOR
ARCHITECT

572 NORTH BROADWAY


WHITE PLAINS, NEW YORK 10603

TEL 914 289 0011

A SECTION VIEW
A SECTION VIEW

CASH REGISTER CASH REGISTER CASH REGISTER CASH REGISTER CASH REGISTER CASH REGISTER CASH REGISTER CASH REGISTER

COLUMN
ACCESS COVER PLATE
(TYPICAL) ACCESS COVER PLATE
(TYPICAL)

FINISHED FLOOR JB JB JB JB JB JB JB JB FINISHED FLOOR LIC # AR0015561


I.G. DATA I.G. I.G. I.G. I.G. DATA DATA I.G. I.G. I.G. I.G. DATA I.G.

A (TYPICAL OUTLET CONFIGURATION)


A
CASH WRAP, REFER TO POWER
DATA JACKS MOUNTED IN E.C. SUPPLIED 4" BOX
PLAN(S) FOR IN FLOOR ROUTING. (1) QUAD CONVENIENCE RECEPTACLE WITH SINGLE GANG PLASTER RING ATTACHED TO
PROVIDE END BUSHING ON CONDUIT. MOUNTED VERTICALLY TO BACK SIDE
BACK SIDE OF MILLWORK. LOCATE DIRECTLY
OF MILLWORK LOCATED DIRECTLY
UNDER ACCESS COVER PLATE BELOW FOLDING
JUNCTION BOX FOR CASH WRAP UNDER THE ACCESS COVER PLATE
AREA/SELVES FOR BAGS. SEE POWER PLANS FOR
BRANCH CIRCUIT NORMAL POWER BELOW FOLDING AREA/ SELVES FOR
EXACT QUANTITY OF DATA JACKS REQUIRED.
WIRING, REFER TO POWER PLAN(S) BAGS (TYPICAL). SYMBOL ON DWG. - (#D)
SYMBOL ON DWG. -
FOR IN FLOOR CONDUIT ROUTING. (1 EXP. 2/28/2025
1/2" C MIN.) (ONLY USED IF (1) QUAD ISOLATED GROUND
TRENCHING IS PERMITTED) RECEPTACLE MOUNTED VERTICALLY
JUNCTION BOX FOR CASH WRAP
TO BACK SIDE OF MILLWORK LOCATED REVISION:
DIRECTLY UNDER THE ACCESS COVER
BRANCH CIRCUIT ISO. GROUND POWER
PLATE BELOW FOLDING AREA/ SELVES
WIRING, REFER TO POWER PLAN(S)
FOR BAGS (TYPICAL). SYMBOL ON
FOR IN FLOOR CONDUIT ROUTING. (1
DWG. - IG
1/2" C MIN.) (ONLY USED IF TRENCHING
IS PERMITTED)

BACKVIEW @ CASHPOINT (EACH HALF OF [8] REGISTER 1


NO SCALE

ISSUE DATE:
06.12.23 FOR REVIEW & APPROVALS
07.17.23 FOR BIDS & PERMITS
NOTE:
CASH REGISTER CASH REGISTER
ALL WORK TO BE DONE PER LATEST H&M
(1) QUAD CONVENIENCE RECEPTACLE, GUIDELINE STANDARDS, 'HOW TO BUILDS' AND
(1) QUAD I.G. RECEPTACLE, AND DATA
JACKS MOUNTED TO BACK SIDE OF MANUFACTURERS INSTRUCTION.
MILLWORK, LOCATED UNDER THE
ACCESS COVER PLATE ACCESS COVER PLATE BELOW FOLDING ACCESS COVER PLATE
(TYPICAL) AREA/SELVES FOR BAGS (TYPICAL).
GENERAL NOTES ARCH PROJECT NO.: 10835
PRODUCT SEASON: 2024
1. NOT USED
REFER TO DRAWING E410 AND E420 FOR QUANTITY AND LOCATIONS OF ALL POWER AND DATA DEVICES. SPACE NO.: 185
2. ALL JACKS ARE ARBITRARILY LABELED AS DATA, AS DATA AND TELEPHONE USE THE SAME JACKS. THE
DRAWN BY: JTA

5 3/4"
H&M I.T. REPRESENTATIVE SHALL DETERMINE WHICH JACKS ARE FOR DATA AND WHICH ARE FOR SCALE: AS NOTED
JB JB FINISHED FLOOR TELEPHONES (TYPICAL).
I.G. I.G. DATA DATA I.G. I.G.
3. ALL FLOOR CONDUIT PENETRATIONS SHALL BE FIRE RATED OR FIRE STOPPED AS REQUIRED BY THE
HAND HOLE FOR ROLL-UP HOLIDAY
LOCAL JURISDICTION AND/OR LANDLORD. SHEET TITLE:
CASHWRAPS. 4. PROVIDE HUBBELL SS309B BLANK FACEPLATES FOR UNUSED PEDESTAL COMPARTMENTS.
ENLARGED CASHWRAP
5. THIS PLAN SHOWS BOTH TYPES OF CASHWRAP ROUTING. REFER TO PLANS FOR TYPE OF ROUTING (IE ELEVATIONS
(1) QUAD CONVENIENCE RECEPTACLE
CASH WRAP, REFER TO POWER
SECTION A-A (TYPICAL) CORE DRILL, TRENCHING). ALL DATA, CONVENIENCE & I.G. RECEPTACLES SHALL BE INSTALLED IN
MOUNTED VERTICALLY TO BACK SIDE LOCATIONS SHOWN. 6. CONVENIENCE & I.G. RECEPTACLE CIRCUITS SHALL BE IN CONDUIT & DATA
PLAN(S) FOR IN FLOOR ROUTING. NO SCALE
OF MILLWORK LOCATED DIRECTLY CABLING SHALL BE RAN WITHOUT CONDUIT BELOW CASHWRAP ONLY. ALL HOMERUNS (DATA,
UNDER THE ACCESS COVER PLATE PROVIDE END BUSHING ON CONDUIT. CONVENIENCE & I.G.) SHALL BE IN E.M.T.
BELOW FOLDING AREA/ SELVES FOR
BAGS (TYPICAL). SYMBOL ON DWG. - JUNCTION BOX FOR CASH WRAP
BRANCH CIRCUIT NORMAL POWER THE ELECTRICAL CONTRACTOR SHALL VERIFY EXISTING CONDITIONS TO INSURE THAT THE NEW WORK WILL
WIRING, REFER TO POWER PLAN(S)
(1) QUAD ISOLATED GROUND FIT TO THE EXISTING STRUCTURE IN THE MANNER INTENDED AND SHOWN ON THE DRAWINGS. SHOULD ANY
FOR IN FLOOR CONDUIT ROUTING. (1

THE MALL AT WELLINGTON GREEN


RECEPTACLE MOUNTED VERTICALLY CONDITIONS EXIST THAT ARE CONTRARY TO THOSE ON THE DRAWINGS, THE CONTRACTOR SHALL NOTIFY
1/2" C MIN.) (ONLY USED IF
TO BACK SIDE OF MILLWORK LOCATED

STORE NO. US 326 - RED MOD

BLVD.WELLINGTON, FL. 33414


TRENCHING IS PERMITTED) THE TENANT'S REPRESENTATIVE PRIOR TO FABRICATION OR PERFORMING ANY WORK IN THE AREA
DIRECTLY UNDER THE ACCESS COVER
PLATE BELOW FOLDING AREA/ SELVES INVOLVING DIFFERENCES. NOTIFICATION SHALL BE IN THE FORM OF A DRAWING OR SKETCH INDICATING
JUNCTION BOX FOR CASH WRAP

10300 W. FOREST HILL


FOR BAGS (TYPICAL). SYMBOL ON BRANCH CIRCUIT ISO. GROUND POWER FIELD MEASUREMENTS AND NOTES RELATED TO THE AREA.
DWG. - IG WIRING, REFER TO POWER PLAN(S)
FOR IN FLOOR CONDUIT ROUTING. (1
1/2" C MIN.) (ONLY USED IF TRENCHING (E.M.T. OR RIGID)
IS PERMITTED) ALL WIRING SHALL BE IN CONDUIT

2024
FLEXIBLE CONDUIT MAY ONLY BE USED FOR FINAL CONNECTIONS FROM OUTLET BOXES TO LIGHT
FIXTURES, MOTORS, APPLIANCES, ETC., MAX. LENGTH 6 FEET.

BACKVIEW @ CASHPOINT (EACH HALF OF [8] REGISTER 2 SECTION A - A (TYPICAL) 3 NOTE:


NO SCALE NO SCALE IT IS THE ELECTRICAL CONTRACTOR'S RESPONSIBILITY TO PROPERLY BALANCE ALL BRANCH CIRCUITS
BETWEEN THE PHASES OF THE SYSTEM FOR EACH ZONE AND/OR CONTACTOR REGARDLESS OF CIRCUIT
INDICATED.

NOTE:
ROOM / CASHWRAP LAYOUTS & LOCATIONS SHOWN FOR BID PURPOSE AND DESIGN INTENT ONLY. E.C.
RESPONSIBLE FOR WORKING SPACE, CLEARANCES, AMD TRANSFORMER FEEDER LENGTHS PER N.E.C. AND
LOCAL CODE.

SHEET NO:

A-762
REV. NO:

D.O.B. NO:
PANELBOARD DESIGNATION LP2 PANELBOARD DESIGNATION LIGA GENERAL NOTE:
120/208 VOLTS 3 PH. 4 WIRE SOLID NEUTRAL MOUNTING: FLUSH - 120/208 VOLTS 3 PH. 4 WIRE SOLID NEUTRAL MOUNTING: FLUSH - THE ELECTRICAL CONTRACTOR SHALL VERIFY EXISTING CONDITIONS TO
225 AMPERE BUS 150 AMPERE MAIN BREAKER X 125 AMPERE BUS 60 AMPERE MAIN BREAKER SURFACE X INSURE THAT THE NEW WORK WILL FIT TO THE EXISTING STRUCTURE IN
SURFACE
SPECIAL REQUIREMENTS SPECIAL REQUIREMENTS INSULATED/ISOLATED GROUND BAR, 200% NEUTRAL THE MANNER INTENDED AND SHOWN ON THE DRAWINGS. SHOULD ANY
CKT. CONDITIONS EXIST THAT ARE CONTRARY TO THOSE ON THE DRAWINGS,
NO. KVA DESCRIPTION A B C DESCRIPTION KVA
CKT FEED THRU LUGS FOR TVSS UNIT
JEFFREY
No.
CKT. KVA
A B C CKT THE CONTRACTOR SHALL NOTIFY THE TENANT'S ARCHITECT &
1 1.2 SALES RECEPTACLE 2.0 CASHWRAPRECEPTACLE 0.8 2 NO. DESCRIPTION DESCRIPTION KVA No.
REPRESENTATIVE PRIOR TO FABRICATION OR PERFORMING ANY WORK IN
1 0.4 HOL. I.G. CASH WRAP 1.0 G
.I CASHWRAPRECEPT . 0.6 2
3

5
1.2 SALES RECEPTACLE

0.6 NIGHTBOX RECEPTACLE


1.6

1.4
CASHWRAPRECEPTACLE

CASHWRAPRECEPTACLE
0.4

0.8 6
4
3 0.4 HOL. I.G. CASH WRAP 1.0 G
.I CASHWRAPRECEPT. 0.6 4
THE AREA.
TAYLOR
7 10.STOCKROOMRECEPTACLE 2.8 ROLLING GRILLE 1.8 8
5 0.4 HOL. I.G. CASH WRAP 1.0 G
.I CASHWRAPRECEPT . 0.6 6 ARCHITECT
9 0.4 COUNTER RECEPTACLE 2.2 ROLLING GRILLE 1.8 10
7 0.4 HOL. I.G. CASH WRAP 1.0 G
.I CASHWRAPRECEPT . 0.6 8 NOTE:
1.4 9 0.2 EMPLOYEETM
I ECLOCK 0.8 G
.I CASHWRAPRECEPT . 0.6 10 IT IS THE ELECTRICAL CONTRACTOR'S RESPONSIBILITY TO PROPERLY
11 1.2 MICROWAVE WATER COOLER 0.2 12 572 NORTH BROADWAY
1.0 BALANCE ALL BRANCH CIRCUITS BETWEEN THE PHASES OF THE SYSTEM
1.6 11 0.4 DECO I.G. RECEPT. G
.I CASHWRAPRECEPT . 0.6 12
3 13 0.8 REFRIGERATOR VENDING MACHINE 0.8 14 3 FOR EACH ZONE AND/OR CONTACTOR REGARDLESS OF CIRCUIT WHITE PLAINS, NEW YORK 10603
13 0.4 DECO I.G. RECEPT. 0.8 ADMIN OFFICE I.G. 0.4 14 INDICATED.
15 0.4 FITTING ROOM RECEPT. 1.2 VENDING MACHINE 0.8 16 3
CLICK & COLLECT 15 0.4 TRAFFIC COUNTER 0.8 ADMIN OFFICE I.G. 0.4 16 TEL 914 289 0011
17 0.2 0.4 DECO RECEPTACLE 0.2 18
LOCKERS
17 0.2 TRAFFIC COUNTER 0.6 ADMIN OFFICE I.G. 0.4 18
C1 2 19 0.9 EF-1 1.1 DECO RECEPTACLE 0.2 20
19 1.0 TV RECEPTACLE 1.4 ADMIN OFFICE DOOR 0.4 20
2 21 1.2 EF-2 1.8 RRJ/ANCLOSETRECEPT. 0.6 22
5 21 0.4 SECURITY RECEPT. 0.8 MANAGER OFFICE I.G. 0.4 22
2 23 1.2 EF-3 2.0 EWC 0.8 24
5 23 0.4 SECURITY J-BOX 0.8 CAMERASYSTEMPOWER 0.4 24
2 25 0.4 VAV-1,2,3,4,5,6,7 1.9 HAND DRYER 1.5 26
5 25 0.4 PEOPLE VIEWER 0.8 SECURITY MONITOR 0.4 26
2 27 0.3 VAV-8,9,10,11 1.1 MANAGER OFFICE RECEPT. 0.8 28
27 0.4 SOUND SYSTEM 0.8 DATA RACK 0.4 28 5
29 0.4 CASHWRAPRECEPTACLE 1.6 CORRIDOR 1.2 30
0.8 29 0.4 SOUND SYSTEM 0.8 DATA RACK 0.4 30 5
31 0.4 CASHWRAPRECEPTACLE CASH WRAP RECEPTACLE 0.4 32
5 31 0.2 EAS RECEPTACLE 0.8 G
.I CASHWRAPRECEPT . 0.6 32
33 - SPARE 0.4 CASHWRAPRECEPTACLE 0.4 34
VISUAL ROOM
1.7 33 0.4 RECEPTACLE 0.9 F.A.C.P. 0.5 34 6
35 0.2 ENERGENT METER HAND DRYER 1.5 36
20 60 1.0
6.7 5 35 0.4 PEOPLE VIEWER G
.I CASHWRAPRECEPT . 0.6 36
37 1.3 EWH-1 S
IOLATEDTRANSFORMER 5.4 38
5 37 0.2 EAS RECEPTACLE 0.8 G
.I CASHWRAPRECEPT . 0.6 38
39 1.3 6.0 (15 KVA PNL LIGA) 4.7 40
39 0.6 G
.I CASHWRAPRECEPT. 1.2 G
.I CASHWRAPRECEPT . 0.6 40
41 0.2 E. STAT PANEL RECEPT. 4.8 4.6 42
41 0.6 G
.I CASHWRAPRECEPT. 1.2 G
.I CASHWRAPRECEPT . 0.6 42
(ZONE C1 OFF) 15.8 14.3 13.3
6.6 6.3 6.4
LIC # AR0015561
KVA SUB TOTALS
(ZONE C1 ON) 16.9 14.3 13.3
TOTAL CONNECTED LOAD - 19.3 KVA
KVA SUB TOTALS 16.9 14.3 13.3
TOTAL CONNECTED LOAD - 44.1 KVA

ELECTRICAL LOAD SUMMARY PANELBOARD NOTES CONTACTOR


SCHEDULE
LOAD DESCRIPTION CONNECTED LOAD (KVA) LOAD DESCRIPTION COMPUTED DEMAND LOAD (KVA) 1. ALLBREAKERSSHALLBE20A1
/PU
, NLESSNOTEDOTHERWS
IE.

45.2 2. 1 INDICATES BREAKER SHALL BE "SWD" RATED. C1 - WORK CONTACTOR


GENERAL LIGHTING: 36.1 CONTINUOUS LOAD x 1.25:
87.5 CONTINUOUS LOAD (2888' x 150w/2ft): 3. 2 INDICATES BREAKER SHALL BE "HACR" RATED. C2 - SALES CONTACTOR EXP. 2/28/2025
TRACK LIGHTING: 216.6
SHOW WINDOW: 15.2 SHOW WINDOW (214' x 200w/ft): 42.8 4. 3 INDICATES BREAKER SHALL BE 5 mA "G.F.I." TYPE. C3 - TRACK/COVE CONTACTOR
HVAC: 4.0 CONTINUOUS LOAD: 4.3 4 C4 - SIGN/DISPLAY CONTACTOR
REVISION:
(INCLUDES 125% OF LARGEST MOTOR) 5. INDICATES BREAKER SHALL BE "H.I.D." RATED.
6. 5 INDICATES BREAKER TO HAVE LOCK-ON CLIP. CA - TRACK CONTACTOR INTEGRAL
RECEPTACLES: 36.8 NONCONTINOUS LOAD: 20.5
(1st 10KW @100% + REMAINING @50%) TO PANEL LP1
7. 6 INDICATES BREAKER TO HAVE LOCK-ON CLIP AND
MISCELLANEOUS: 14.1 NONCONTINUOUS LOAD @100%: 14.1 RED MARKING. CB - TRACK CONTACTOR INTEGRAL
6.4 8. "TC-1", "C#" INDICATES DESIGNATION ZONE OR TIME CLOCK TO PANEL LP4
SIGN: CONTINUOUS LOAD: 6,400VA x 1.25 = 8,000VA 8.0
CONTROLLING CIRCUIT. SEE LIGHTING CONTROL SCHEDULE CC - TRACK CONTACTOR INTEGRAL
TOTAL CONNECTED LOAD: 194.3 TOTAL DEMAND LOAD: 357.3 ON E032 SERIES SHEET. TO PANEL LP5

* REFER TO DWG E-032.00


COMPUTED SERVICE DEMAND LOAD OF 357.3 KVA @ 480/277V-3Ø-4W = 429.8 AMPS
TOTAL NUMBER OF BRANCH CIRCUITS: 236
TOTAL NUMBER OF SPARE CIRCUITS: 41 ISSUE DATE:
06.12.23 FOR REVIEW & APPROVALS
07.17.23 FOR BIDS & PERMITS

ARCH PROJECT NO.: 10835


PRODUCT SEASON: 2024
SPACE NO.: 185
DRAWN BY: JTA
SCALE: AS NOTED

SHEET TITLE:
PARTIAL PANEL SCHEDULE
AND NOTES

THE MALL AT WELLINGTON GREEN


STORE NO. US 326 - RED MOD

BLVD.WELLINGTON, FL. 33414


10300 W. FOREST HILL
2024
SHEET NO:

A-763
REV. NO:

D.O.B. NO:
DOOR SCHEDULE (NOTE: ALL 'EX' NOTED DOORS ON PLANS A200 & A201 ARE EXISTING DOOR & HARDWARE TO REMAIN 'AS-IS' UNLESS OTHERWISE NOTED.)
MATERIAL DETAILS FIRE HDWR BARRICADE
DOOR # LOCATION TYPE SIZE REMARKS
DOOR HEAD JAMB HEAD SILL JAMB RATING SET DEVICE
100 SALES AREA TO 'CLICK & COLLECT' STOCK RM. A 3'-4" x 7'-0" x 1 3/4" HM HM HM 2/A800 - 2/A800 - 7C

JEFFREY
TAYLOR
ARCHITECT
DOOR HARDWARE SCHEDULE F & I BY G.C. (U.O.N.)
SET - 7 (SALES AREA TO B.O.H. OR AS NOTED)
(1 1/2 PAIR) HINGES: STANLEY #FBB191 - US26D 572 NORTH BROADWAY
(1) CLOSER: TO BE MOUNTED ON PULL SIDE - NO HOLD OPEN
(1) PANIC DEVICE: ARROW ED910-36.32D - SIZE TO MATCH DOOR W/ SRX82 EXTERIOR TRIM
DOOR SCHEDULE GENERAL NOTES WHITE PLAINS, NEW YORK 10603
(1) FLOOR STOP: IVES #FS13, US26D 1. DIMENSIONS ON DOOR SCHEDULE SHOWS CLEAR OPENING REQUIRED. CONTRACTOR TO DETERMINE ROUGH OPENING DIMENSIONS - ALL WOOD DOORS TO BE
(1) FLOOR STOP RISER: IVES R14 - US26D (AS REQ'D.) PAINTED. TEL 914 289 0011
(3) DOOR SILENCER: IVES, #SR64 3. PROVIDE SHOP DRAWINGS/ CUTS FOR ALL DOORS AND HARDWARE FOR ARCHITECT & H&M APPROVAL PRIOR TO FABRICATION/ ORDERING.
(1) KICK PLATE: BURNS #KP50 (J102) - 24"H, US32D, MOUNTED ON PUSH SIDE 4. ALL LOCKS TO HAVE INTERCHANGEABLE CORES. PROVIDE BEST 7-PIN WHERE NOTED IN HARDWARE SCHEDULE.
5. EXISTING DOORS & HARDWARE TO BE EVALUATED BY PROJECT TEAM FOR REFURBISH OR REPLACEMENT WITH NEW. DOORS TO BE PAINTED TO MATCH ADJACENT
SET - 7A (FOR PUBLICLY ACCESSIBLE TOILET ROOM ACCESS) WALLS. REPLACE DOOR FRAME IF REQUIRED.
SAME AS SET - 7 EXCEPT WITH PASSAGE LEVER, BEST: 9K-3-0-N-15-D-STK-626 6. COORDINATE ALL DOORS WITH ELECTRIC HARDWARE WITH E.C.
- NO PANIC DEVICE, ELECTRIC STRIKE OR CUBE SYSTEM 7. ALL DOORS TO HAVE SILENCERS UNLESS PERIMETER WEATHER STRIPPING IS PROVIDED. IF SILENCER IS NOT SPECIFIED IN THE HARDWARE SET, USE IVES, MODEL #
SR64.
SET - 7C 8. ALL DOORS USED IN CONNECTION WITH EXIT ACCESS SHALL BE ARRANGED AS TO BE READILY OPENABLE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE
SAME AS SET - 7 EXCEPT REPLACE PANIC DEVICE WITH: OR EFFORT FROM THE SIDE WHICH EGRESS IS MADE. NO THUMB TURNS OR DEADBOLTS ARE PERMITTED ON EGRESS DOORS.
YALE 'NEXTOUCH' KEYPAD LOCK 9. DOORS REQ'D. TO BE ACCESSIBLE WITH HARDWARE THAT IS HAND ACTIVATED SHALL BE OPERABLE WITH A SINGLE EFFORT BY LEVER TYPE HARDWARE, PANIC BARS,
LEVER DESIGN: AU PUSH-PULL ACTIVATING BARS, OR OTHER HARDWARE DESIGNED TO PROVIDE PASSAGE WITHOUT REQUIRING TIGHT GRASPING, TIGHT PINCHING, OR TWISTING
SERIES FUNCTION: NTT620 OF THE WRIST TO OPERATE.
TECHNOLOGY : NR 10. HAND OPERATED HARDWARE/DEVICES SHALL BE CENTERED BETWEEN 34" MIN. AND 48" MAX. ABOVE FINISHED FLOOR. LOCKS USED ONLY FOR SECURITY PURPOSES
FINISH: 626 AND NOT USED FOR NORMAL OPERATION ARE PERMITTED AT ANY HEIGHT.
LEVER DESIGN: AU 11. FORCE TO OPERATE INTERIOR SWINGING EGRESS DOORS (OTHER THAN FIRE DOORS) SHALL NOT EXCEED FIVE (5) POUNDS, SUCH PULL OR PUSH EFFORT BEING
CYLINDER / KEYWAY : INTERCHAGE CORE CYLINDER #2196) APPLIED AT RIGHT ANGLES TO THE LATCH SIDE OF DOOR. FOR OTHER THAN SWINGING DOORS, AS WELL AS SLIDING AND FOLDING DOORS, THE DOOR LATCH
ADVANCED FUNCTION: TO BE COORDINATED WITH H&M SECURITY TEAM SHALL RELEASE WHEN SUBJECT TO A 15 POUND FORCE. DOOR SHALL SWING TO A FULL OPEN POSITION WHEN SUBJECT TO A 15 POUND FORCE.
12. HORIZONTAL SLIDING OR VERTICAL SECURITY GRILLES ARE PERMITTED AT THE MAIN EXIT AND SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF KEY OR
COORDINATE COMPATIBLE EXIT DEVICE, DPS (DOOR POSITION SPECIAL KNOWLEDGE OR EFFORT DURING PERIODS THAT THE SPACE IS OCCUPIED. THE GRILLES SHALL REMAIN SECURED IN THE FULL OPEN POSITION DURING
SENSOR) AND BATTERY BACKUP DEVICE (IF REQUIRED) BUSINESS HOURS.
13. KEY ALL DOORS ALIKE. PRIOR TO CONSTRUCTION, G.C. SHALL VERIFY WITH HARDWARE SUPPLIER AND ARCHITECTURAL CONSULTANT THAT ALL DOOR HARDWARE
FOLLOW THE LINK BELOW FOR ADDITIONAL SPECIFICATIONS AND INSTALLATION INSTRUCTIONS. MEETS ALL STATE AND LOCAL CODES AND ORDINANCES. NOTIFY OWNER OF ANY DISCREPANCIES.
https://www.trudoor.com/yale/b-au-ntb622-nr-nextouch-capactive-touchscreen-cylindrical-lock-for-sfic/ 14. ALL LOCKING DEVICES AND PANIC HARDWARE SPECS. SHALL BE COMMERCIAL GRADE & VERIFIED WITH THE AHJ.
15. ALL DOORS & HARDWARE SHALL CONFORM TO CURRENT APPLICABLE STANDARDS FOR HANDICAPPED ACCESSIBILITY. LIC # AR0015561
16. EXIT DOORS SHALL BE OF A SIZE AS TO PERMIT THE INSTALLATION OF A DOOR NOT LESS THAN 3' WIDE OR 68" HIGH. NO DOOR LEAF SHALL EXCEED 4'W.
17. DOORS WIDTHS GREATER THAN 36" TO HAVE CONTINUOUS HINGE AND WELDED FRAME (NO KNOCKDOWN TYPE.) PROVIDE EXTRA MTL. STUD FRAME AND HEADER
STRUCTURE.

DOOR TYPE ELEVATIONS

METAL STUD AND GYP. BD. WALL


CONSTRUCTION REFER TO
CONSTRUCTION PLAN & PARTITION EXP. 2/28/2025
TYPES FOR WALL TYPE
F.R.T. PLYWOOD AS REQUIRED

ALIGN
REVISION:
CAULKING. COLOR TO MATCH HOLLOW METAL DOOR FRAME
ADJACENT WALL.

SALES AREA
VARIES
HOLLOW METAL DOOR. PAINTED
TO MATCH ADJACENT WALL
BACK OF HOUSE
HEADER

BACK OF HOUSE

SEE DOOR SCHEDULE


HOLLOW METAL DOOR
ISSUE DATE:
06.12.23 FOR REVIEW & APPROVALS

±4 7/8"
VARIES
HOLLOW METAL DOOR FRAME. PAINT TO 07.17.23 FOR BIDS & PERMITS
MATCH ADJACENT WALL PANEL

F.R.T. PLYWOOD AS REQUIRED

CAULKING. COLOR TO MATCH


ADJACENT WALL.
ALIGN
TYPE 'A'
PTD HOLLOW SALES AREA SALES AREA WALL PANEL FURNISHED BY
METAL DOOR JAMB H&M AND INSTALLED BY G.C.
ARCH PROJECT NO.: 10835
PRODUCT SEASON: 2024
SPACE NO.: 185
DOOR TYPE ELEVATIONS 1 DETAILS - HOLLOW METAL JAMB/HEADER (IN SWING) 2 DRAWN BY: JTA
SCALE: 3" = 1'-0" SCALE: AS NOTED
SCALE: N.T.S.

SHEET TITLE:

DOOR SCHEDULE

THE MALL AT WELLINGTON GREEN


STORE NO. US 326 - RED MOD

BLVD.WELLINGTON, FL. 33414


10300 W. FOREST HILL
2024
SHEET NO:

A-800
REV. NO:

D.O.B. NO:
SECTION 08 14 00 - WOOD DOORS SECTION 08 70 00 - HARDWARE SECTION 09 51 23 - ACOUSTICAL TILE CEILINGS SECTION 11 30 13 - APPLIANCES

A. GENERAL: PROVIDE WOOD DOORS AS REQUIRED FOR COMPLETE INSTALLATION; A. GENERAL: PROVIDED DOOR HARDWARE FOR HOLLOW METAL AND WOOD DOORS AND PROVIDE A. GENERAL: PROVIDE ACOUSTICAL CEILINGS INCLUDING SUSPENSION SYSTEM, TRIM, AND ACCESSORIES AS REQUIRED FOR A. GENERAL: PROVIDE APPLIANCES WITH ACCESSORIES AS REQUIRED FOR COMPLETE OPERATIONAL
COORDINATE WITH FRAMES AND HARDWARE. CYLINDERS FOR DOORS PROVIDED WITH HARDWARE, WITH ACCESSORIES AS REQUIRED FOR COMPLETE COMPLETE FINISHED INSTALLATION. INSTALLATION.
B. STANDARDS: COMPLY WITH WINDOW AND DOOR MANUFACTURER ASSOCIATION OPERATIONAL DOOR INSTALLATIONS. B. STANDARDS: CONFORM TO ASTM C635 FOR METAL SUSPENSION SYSTEM AND ASTM C636 FOR INSTALLATION OF B. MANUFACTURERS: FRIGIDAIRE, GENERAL ELECTRIC, HOTPOINT, WHIRLPOOL, OR IN-SINK-ERATOR.
(WDMA) INDUSTRY STANDARDS FOR WOOD DOORS. B. STANDARDS: COMPLY WITH BUILDERS HARDWARE MANUFACTURERS ASSOCIATIONS (BHMA) ACOUSTICAL CEILINGS. C. APPLIANCES: PROVIDE APPLIANCES EACH AS A COMPLETE UNIT WITH OPTIONS AND ACCESSORIES
C. MANUFACTURERS: ALGOMA, EGGERS, MARSHFIELD OR APPROVED EQUAL.
D. FLUSH SOLID CORE DOORS: FIVE PLY 1-3/4” THICK DOORS WITH PAINT GRADE WHITE
BIRCH VENEERS AND LUMBER STAVE CORE OR PARTICLEBOARD CORES; MINERAL CORE
ANSI/BHMA 156 SERIES STANDARDS.
C. CODES AND REGULATIONS: COMPLY WITH STATE AND FEDERAL REQUIREMENTS FOR ENSURING ACCESS
FOR PERSONS WITH DISABILITIES. NOT USED
C. MANUFACTURES: ARMSTRONG; NO SUBSTITUTIONS.
D. SUSPENSION SYSTEM: ARMSTRONG/PRELUDE EXPOSED 15/16” “T” GRID SYSTEM, 7300 BEAM, 7800 WALL MOLDING,
DIRECT HUNG, WHITE BAKES ENAMEL FINISHED STEEL OR ALUMINUM TYPE; EDGE TRIM WITH VERTICAL LEG CONCEALED.
AS DIRECTED AND AS REQUIRED FOR COMPLETE OPERATIONAL CODE COMPLIANT INSTALLATION.
1. TYPES: REFER TO DRAWINGS FOR APPLIANCES
D. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS.

NOT USED
PERMITTED AT 45 MINUTE AND HIGHER FIRE RATED UNITS.
E. FIRE RATED UNITS: CONFORM TO NFPA 80; PROVIDE UL OR WARNOCK HERSEY
LABELED FRAMES AS REQUIRED.
D. HINGES: FULL MORTISED BUTT HINGES; SIZE AND NUMBER AS RECOMMENDED BY MANUFACTURER;
NON-REMOVABLE PINS AT EXTERIOR OUT SWINGING DOORS, BALL-BEARING HINGES AT FIRE RATED
DOORS AND DOORS WITH CLOSERS. CONTINUOUS HINGE AT DOORS OVER 36" WIDE.
E. ACOUSTICAL UNITES: ARMSTRONG DUNE #1772, 24”X 24”X5/8” PANELS OR AS INDICATED ON DRAWINGS.
1. FIRE RATINGS: PROVIDE SYSTEMS WITH FLAME SPREAD AND SMOKE DENSITY RATINGS OF 25/450 UNLESS
OTHERWISE INDICATED.
END OF SECTION JEFFREY
TAYLOR
F. ACCESSORIES: PROVIDE TYPE II ADHESIVE FOR INTERIOR APPLICATIONS; PROVIDE 1. MANUFACTURERS: HAGER, LAWRENCE, MCKINNEY, OR STANLEY F. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS, REFERENCED STANDARDS, AND APPLICABLE SECTION 14 24 00 - HYDRAULIC ELEVATOR
MATCHING WOOD GLAZING STOPS AS APPROVED BY ARCHITECTS FOR GLAZING IN E. LOCKSETS/LATCHSETS: FULL MORTISE LOCKSETS TYPICAL; SOLID LEVER TYPE WITH ROSE; KEYING AS REQUIREMENTS FOR FIRE RATINGS.
WOOD DOORS. DIRECTED BY OWNER, PROVIDE CYLINDERS FOR DOOR FURNISHED WITH LOCKS. A. GENERAL: OWNER TO PROVIDE ELEVATOR AND ACCESSORIES AS REQUIRED FOR COMPLETE ARCHITECT
G.INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS, WDMA, AND 1. MANUFACTURERS: BEST. END OF SECTION OPERATIONAL FINISHED INSTALLATION.
APPLICABLE REQUIREMENTS FOR FIRE RATINGS. F. OVERHEAD CLOSERS: FULLY ADJUSTABLE; MODERN TYPE WITH COVER. B. STANDARDS: COMPLY WITH ANSI A17.1, SAFETY CODE FOR ELEVATORS, AND WITH NFPA 70,
1. MANUFACTURERS: LCN/4000 SERIES, NORTON/7500, OR DORMA/TS83U2. SECTION 09 65 19 - RESILIENT TILE FLOORING NATIONAL ELECTRICAL CODE. 572 NORTH BROADWAY
END OF SECTION G.ACCESSORIES: PROVIDE DOORS STOPS, THRESHOLDS, WEATHER-STRIPPING TRIM, COORDINATORS C. CODES AND REGULATIONS: COMPLY WITH APPLICABLE CODES AND REGULATIONS FOR WHITE PLAINS, NEW YORK 10603

SECTION 08 31 00 - ACCESS DOORS AND PANELS

A. GENERAL: PROVIDE ACCESS DOORS AS REQUIRED FOR ACCESS TO VALVES AND


AND ACCESSORIES AS REQUIRED FOR COMPLETE OPERATIONAL DOOR INSTALLATION.
1. GASKETING: PROVIDE COMPLETE ACOUSTICAL GASKETING FOR DOORS AT MECHANICAL ROOMS,
ELECTRICAL ROOMS AND ELEVATOR EQUIPMENT ROOMS, INCLUDING AUTOMATIC DOOR
BOTTOMS.
A. GENERAL: PROVIDE RESILIENT TILE FLOORING SYSTEM AND RESILIENT BASE, WITH ACCESSORIES AS REQUIRED FOR
COMPLETE FINISHED INSTALLATION.
B. VCT FLOORING: ASTM F1066, COMPOSITION 1 (NON-ASBESTOS), 1/8” THICK VINYL COMPOSITION TILE, 12” BY 12”.
1. MANUFACTURERS: ARMSTRONG, AZROCK OR TARKETT.
NOT USED
ELEVATORS INCLUDING REQUIREMENTS FOR PROVIDING ACCESS FOR PERSONS WITH DISABILITIES.
1. AMBULANCE GURNEY ACCESS: COMPLY WITH REQUIREMENTS FOR ACCESS TO ONE ELEVATOR
SERVING EACH FLOOR.
D. MANUFACTURER: SEE ARCHITECTURAL DRAWINGS
TEL 914 289 0011

CONTROLS LOCATED BEHIND FINISHED WALLS AND CEILINGS NOT OTHERWISE H. EXTERIOR HARDWARE FINISH: BHMA 630 (US32D), SATIN FINISHED STAINLESS STEEL. C. EDGE STRIP AND ACCESSORIES: RUBBER OR VINYL EDGE STRIPS MATCHING RESILIENT FLOORING; LATEX-MODIFIED E. TYPE: SEE ARCHITECTURAL DRAWINGS
ACCESSIBLE, WITH ACCESSORIES FOR COMPLETER INSTALLATION. I. INTERIOR HARDWARE FINISH: BHMA 626 (US26D), SATIN FINISHED CHROMIUM PLATED. PORTLAND CEMENT BASED UNDERLAYMENT AND PATCHING COMPOUND; NONTOXIC WATER RESISTANT TYPE ADHESIVES. F. ELEVATOR CHARACTERISTICS: COMPLY WITH FOLLOWING UNLESS OTHERWISE INDICATED.
B. MANUFACTURES: 'INTEXFORM' RADIAL CORNER OR APPROVED EQUAL. J. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS BHMA, AND APPLICABLE D. FLAMMABILITY: 0.45 WATTS/CM2 OR HIGHER, ASTM E648 1. WEIGHT CAPACITY: AS PROVIDED
C. TYPE: FLUSH TYPE AT NON FIRE RATED CONSTRUCTION; KEY OPERATED. REQUIREMENTS FOR ACCESS AND FOR FIRE RATINGS. E. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS; PREPARE SUBSTRATES IN ACCORDANCE WITH ASTM 2. SPEED: AS PROVIDED
D. INSTALLATION: COMPLY WITH MANUFACTURE RECOMMENDATIONS AND APPLICABLE F710. 3. CONTROL: MICROPROCESSOR CONTROLLED SELECTIVE COLLECTIVE OPERATION WITH
REQUIREMENTS FOR FIRE RATINGS END OF SECTION STARTER.
END OF SECTION G.ELEVATOR FINISHES:
END OF SECTION SECTION 08 71 13 - AUTOMATIC DOOR OPERATORS 1. HOISTWAY DOORS AND FRAMES: STAINLESS STEEL, NUMBER 4 FINISH.
SECTION 09657 - RESILIENT BASE 2. CAB DOOR/FRONT PANELS: STAINLESS STEEL WITH INTEGRAL CONTROL PANELS.
SECTION 08 33 26 - OVERHEAD COILING GRILLES A. GENERAL: PROVIDE LOW ENERGY DOOR OPERATORS FOR SWINGING DOORS WITH ACCESSORIES AS 3. CAB SIDE AND BACK WALLS: STAINLESS STEEL RIGIDIZED & MIRROR.
REQUIRED FOR COMPLETE OPERATIONAL INSTALLATION; SYSTEM TO OPEN AND CLOSE DOOR UPON A. GENERAL: PROVIDE RESILIENT BASE WITH ACCESSORIES AS REQUIRED FOR COMPLETE FINISHED INSTALLATION,. 4. CEILING: STAINLESS STEEL WITH DOWNLIGHTS.
A. GENERAL: PROVIDE OVERHEAD COILING GRILLES WITH ACCESSORIES AS REQUIRED FOR RECEIPT OF AN ACTUATING SIGNAL. B. MANUFACTURERS: ARMSTRONG, AZROCK OR TARKETT. 5. FLOORING: TILE PROVIDED UNDER SECTION 09300 - TILE.
COMPLETE OPERATIONAL INSTALLATION. 1. PROVIDE AT EXTERIOR ENTRANCE DOORS TO MEET REQUIREMENTS FOR ACCESS FOR PERSONS C.BASE: PROVIDE VINYL BASE WITH PREMOLDED CORNERS AND ENDS; COVE TYPE, 4” HIGH. 6. RAILINGS: STAINLESS STEEL TUBULAR RAILS ON THREE SIDES
B. MANUFACTURERS: METRO DOOR, ALUMATEC PACIFIC PRODUCTS AND BEST CLOSURE WITH DISABILITIES. D. ACCESSORIES: NONTOXIC WATER RESISTANT TYPE ADHESIVES. 7. PADS: PROVIDE COMPLETE SET OF PADS TO PROTECT ELEVATOR FINISHES.
(PREFERRED, BUT NO REQUIRED). TYPE: ELECTRICALLY OPERATED TYPE, WITH SAFETY B. STANDARDS: COMPLY WITH BUILDERS HARDWARE MANUFACTURERS ASSOCIATION (BHMA) ANSI/BHMA E. FLAMMABILITY: 0.45 WATTS/CM2 OF HIGHER ASTM E648 H. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS, REFERENCED STANDARDS,
RELEASE FOR EMERGENCY EXITING. PERFORATED ANODIZED ALUMINUM CURTAIN, 156.19. F. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS; PREPARE SUBSTRATES IN ACCORDANCE WITH ASTM AND APPLICABLE CODES AND REGULATIONS.
POSTS, BOTTOM BAR, KEY SWITCHES AND PANIC DEVICE TO BE WHITE. I. MAINTENANCE: STARTING AT DATE OF SUBSTANTIAL COMPLETION, PROVIDE 12 MONTH LIC # AR0015561
C. CODES AND REGULATIONS: COMPLY WITH STATE AND FEDERAL REQUIREMENTS FOR ENSURING ACCESS F710.
C. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS.

END OF SECTION
NOT USED
FOR PERSONS WITH DISABILITIES.
D. LOW ENERGY DOOR OPERATORS: COMPLETE OPERATOR SYSTEM DESIGNED FOR TYPE OF DOORS
INDICATED AND COMPLYING WITH REQUIREMENTS OF ANSI A156.19 FOR LOW ENERGY POWER
END OF SECTION MAINTENANCE PROGRAM.

END OF SECTION
OPERATED DOOR OPERATORS. SECTION 09 90 00 - PAINTS AND COATINGS
SECTION 08 41 13 - ALUMINUM FRAMED ENTRANCES AND STOREFRONTS 1. MANUFACTURERS: HORTON AUTOMATIC/SERIES 7000; LCN/4600 SERIES ELECTRICALLY POWERED SECTION 14 30 00 - ESCALATORS
AUTO-EQUALIZER; DOR-O-MATIC, INC/SENIOR-SWING AUTOMATIC OPERATION. A. GENERAL: PROVIDE PAINTING OF EXPOSED ITEMS AND SURFACES NOT PREFINISHED, AS REQUIRED FOR COMPLETE
A. GENERAL: PROVIDE EXTRUDED ALUMINUM ENTRANCE SYSTEM DOORS, FRAMES, E. ACCESSORIES: PROVIDE ACCESSORIES AS REQUIRED FOR COMPLETE OPERATIONAL INSTALLATION. FINISHED INSTALLATION. A. GENERAL: PROVIDE ESCALATORS AND ACCESSORIES AS REQUIRED FOR COMPLETE OPERATIONAL
HARDWARE, AND ACCESSORIES AS REQUIRED FOR COMPLETE WEATHER TIGHT F. FINISH: AS DIRECTED BY ARCHITECT BASED ON APPLICATIONS INVOLVED; PRIME PAINTED AT STEEL AND 1. SURFACES NOT TO BE PAINTED: PREFINISHED ITEMS; CONCEALED AREAS, CODE-REQUIRED LABELS. FINISHED INSTALLATION.
INSTALLATION. AT WOOD DOORS, CLEAR ANODIZED ALUMINUM AT ALUMINUM AND GLASS DOORS. B. SUBMITTALS: FURNISH PRODUCT DATA SAMPLES. DUPLICATE PAINTED FINISHES OF APPROVED SAMPLES ON ACTUAL WALL B. STANDARDS: COMPLY WITH ANSI A17.1, SAFETY CODE FOR ELEVATORS AND ESCALATORS, AND
B. STANDARDS: COMPLY WITH ARCHITECTURAL ALUMINUM MANUFACTURERS G.INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS, BHMA, AND APPLICABLE SURFACES AND COMPONENTS FOR APPROVAL PRIOR TO COMMENCING WORK. WITH NFPA 70, NATIONAL ELECTRICAL CODE.
ASSOCIATION (AAMA) “ALUMINUM STORE FRONT AND ENTRANCE MANUAL.”
C. CODES AND REGULATIONS: COMPLY WITH STATE AND FEDERAL REQUIREMENTS FOR
ENSURING ACCESS FOR PERSONS WITH DISABILITIES INCLUDING ACCEPTABLE
LOCATIONS FOR HAND OPERATED HARDWARE.
REQUIREMENTS FOR PERSONS WITH DISABILITIES.

END OF SECTION
C. STANDARDS: PROVIDE MATERIALS APPROVED FOR USE BY APPLICABLE AIR QUALITY MANAGEMENT DISTRICT FOR
LIMITATIONS OF VOLATILE ORGANIC COMPOUNDS FOR ARCHITECTURAL COATINGS.
D. MANUFACTURERS: BENJAMIN MOORE ULTRA; CUSTOM COLORS AS DIRECTED BY ARCHITECT.
E. MATERIAL QUALITY: PROVIDE TOP LINE QUALITY COMMERCIAL GRADE (PROFESSIONAL PAINTER) PAINTS; MATERIALS NOT
ESCALATORS.
NOT USED
C. CODES AND REGULATIONS: COMPLY WITH APPLICABLE CODES AND REGULATIONS FOR

D. MANUFACTURER: SEE ARCHITECTURAL DRAWINGS


E. TYPE: 40” WIDE (2) FLAT STEP, SEE ARCHITECTURAL DRAWINGS REVISION:
EXP. 2/28/2025

D. MANUFACTURERS: KAWNEER, VISTAWALL, ARCADIA OR APPROVED EQUAL. SECTION 09 21 00 - GYPSUM BOARD ASSEMBLIES BEARING MANUFACTURER'S IDENTIFICATION AS A BEST-GRADE PRODUCT NOT ACCEPTABLE. F. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS, REFERENCED STANDARDS,
E. TYPE: MANUFACTURER'S STANDARD EXTRUDED ALUMINUM ENTRANCE SYSTEM WITH 1. PRIMERS: PROVIDE PREMIUM GRADE PRIMERS RECOMMENDED BY PAINT MANUFACTURER FOR SUBSTRATES INDICATED AND APPLICABLE CODES AND REGULATIONS.
PROFILES AS INDICATED ON DRAWINGS. A. GENERAL: PROVIDE GYPSUM BOARD SYSTEMS INCLUDING LIGHT GAGE (20 GAGE AND LIGHTER) METAL AND FOR FINISH SYSTEMS SPECIFIED. G.MAINTENANCE: STARTING AT DATE OF SUBSTANTIAL COMPLETION, PROVIDE 12 MONTH
1. DOOR TYPE: AS INDICATED ON DRAWINGS FRAMING, GYPSUM BOARD, JOINT TREATMENT, ACOUSTICAL INSULATION, ACOUSTICAL SEALANT, AND 2. UNDERCOATS AND BARRIER COATS: PROVIDE UNDERCOAT PAINTS PRODUCED BY SAME MANUFACTURER AS FINISH MAINTENANCE PROGRAM.
2. DOOR HARDWARE: AS APPROVED BY ARCHITECT ACCESSORIES AS REQUIRED FOR COMPLETE INSTALLATION. COATS; USE ONLY THINNERS APPROVED BY PAINT MANUFACTURER, AND USE ONLY WITHIN RECOMMENDED LIMITS.
3. ENTRANCE SYSTEM FLUSH: AS APPROVED BY ARCHITECTS B. STANDARDS: PERFORM GYPSUM BOARD SYSTEMS WORK IN ACCORDANCE WITH ASTM C754 AND 3. COLORS AND FINISHES: PRIOR TO COMMENCEMENT OF PAINTING WORK, ARCHITECT WILL FURNISH COLOR CHIPS END OF SECTION
F. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS AND AAMA ASTM C840 UNLESS OTHERWISE SPECIFIED. FOR SURFACES TO BE PAINTED.
STANDARDS

NOT USED 1. FIRE-RATED ASSEMBLIES: LISTED BY UL, GYPSUM ASSOCIATION (GA) FILE NO'S IN GA-600 FIRE F. PREPARATION: PERFORM PREPARATION AND CLEANING PROCEDURES IN ACCORDANCE WITH PAINT MANUFACTURER'S TILE INSTALLATION AND CLEANING:
RESISTANCE DESIGN MANUAL OR OTHER LISTING APPROVED BY APPLICABLE AUTHORITIES. INSTRUCTIONS AND AS SPECIFIED FOR SUBSTRATE CONDITION. REMOVE ITEMS IN PLACE AND NOT TO BE PAINTED, OR
END OF SECTION C. SYSTEMS RESPONSIBILITY: PROVIDE PRODUCTS MANUFACTURED BY OR RECOMMENDED BY PROVIDE PROTECTION; AFTER PAINTING REINSTALL ITEMS. GENERAL INFORMATION:
MANUFACTURER OF GYPSUM BOARD TO MAINTAIN SINGLE-SOURCE RESPONSIBILITY FOR SYSTEM. G.APPLICATION: APPLY PAINT IN ACCORDANCE WITH MANUFACTURER'S DIRECTIONS; USE APPLICATORS AND TECHNIQUES
SECTION 08 41 26 - ALL-GLASS ENTRANCES AND STOREFRONTS 1. OPENINGS: OBTAIN DIMENSIONS AND LOCATIONS FROM OTHER TRADES AND PROVIDE OPENINGS BEST SUITED FOR SUBSTRATE AND TYPE OF MATERIAL BEING APPLIED. APPLY ADDITIONAL COATS WHEN STAINS OR IF ONE HAS BEEN USED, REMOVE GROUT RELEASE AND CLEAN TILE SURFACES SO THAT THEY ARE ISSUE DATE:
AND ENCLOSURES FOR ACCESSORIES, SPECIALTIES, EQUIPMENT, AND DUCTWORK. BLEMISHED SHOW THROUGH FINAL COAT, UNTIL PAINT IS UNIFORM IN APPEARANCE. FREE OF GROUT AND FOREIGN MATTER, IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. 06.12.23 FOR REVIEW & APPROVALS
A. GENERAL: PROVIDE ALL-GLASS ENTRANCES INCLUDING DOORS, SIDELIGHTS, SIDELIGHT D. SUBMITTALS: SUBMIT PRODUCT DATA AND SAMPLES OF SPECIAL TEXTURE. 1. FINISH DOORS ON TOPS, BOTTOMS AND SIDE EDGES SAME AS FACES. IF A GROUT HAZE OR RESIDUE REMAINS USE A SUITABLE GROUT REMOVER OR CLEANER AND 07.17.23 FOR BIDS & PERMITS
FRAMING, HARDWARE AND ACCESSORIES AS REQUIRED FOR COMPLETE INSTALLATION; E. MANUFACTURERS: USG, GEORGIA PACIFIC, OR NATIONAL GYPSUM H. MINIMUM COATING THICKNESS: APPLY AT NOT LESS THAN MANUFACTURER'S RECOMMENDED SPREADING RATE, TO CONTACT GROUT MANUFACTURER FOR RECOMMENDATIONS. FLUSH SURFACE WITH CLEAN
COORDINATE WITH ADJACENT CONSTRUCTION. F. LIGHT GAGE METAL (STUD) FRAMING: CONFORM TO ASTM C754; COMPLETE 20 GAGE AND LIGHTER ESTABLISH DRY FILM THICKNESS AS RECOMMENDED BY COATING MANUFACTURER. WATER BEFORE AND AFTER CLEANINGS. DO NOT USE HARSH HYDROCHLORIC, MURIATIC OR
B. CODES AND REGULATIONS: COMPLY WITH STATE AND FEDERAL REQUIREMENTS FOR STEEL FRAMING AND SUSPENSION SYSTEM FOR GYPSUM BOARD SYSTEMS. I. PRIME COATS: APPLY TO ITEMS NOT PREVIOUSLY PRIMED; RECOAT PRIMED AND SEALED SURFACES WHERE THERE IS SULFURIC ACID OR ACID-BASED CLEANERS TO CLEAN GLAZED TILES OR TILES GROUTED WITH LATEX
ENSURING ACCESS FOR PERSONS WITH DISABILITIES INCLUDING ACCEPTABLE 1. RESILIENT CHANNELS: SCREW-TYPE RESILIENT CHANNELS WHERE INDICATED AND WHERE REQUIRED EVIDENCE OF SUCTION SPOTS OR UNSEALED AREAS IN FIRST COAT. MODIFIED GROUT.
LOCATIONS FOR HAND OPERATED HARDWARE. TO PROVIDE REQUIRED SOUND TRANSMISSION AND IMPACT ISOLATION CLASSIFICATIONS. J. FINISH COATS: PROVIDE EVEN TEXTURE; LEAVE NO LAPS, IRREGULARITY IN TEXTURE, SKID MARKS, OR OTHER SURFACE 1. AFTER TILE AND GROUT HAVE SET AND CURED, SPONGE AND WASH TILE THOROUGHLY WITH
C. MANUFACTURER: BLUMCRAFT, VIRGINIA GLASS, BRITE VUE OR APPROVED EQUAL. G.GYPSUM BOARD MATERIALS: PROVIDE MATERIALS IN ACCORDANCE WITH ASTM C840 IMPERFECTIONS. APPROVED NEUTRAL CLEANER, IN ACCORDANCE WITH MANUFACTURER'S DIRECTIONS. POLISH
D. TYPE: ASTM C1048, KIND FT, FULLY TEMPERED SAFETY GLASS DOOR AND SIDELIGHT 1. GYPSUM BOARD: ASTM C36, TYPE X FIRE RATED; COMPLY WITH ASTM C840; MAXIMUM K. PAINT SYSTEMS: PROVIDE MINIMUM TWO COAT PLUS PRIMER SYSTEMS. FINALLY WITH CLEAN, DRY CLOTHS.
SYSTEM WITH CONCEALED CLOSES, PIVOTS, PUSH/PULL, THRESHOLDS, LOCK PERMISSIBLE LENGTHS ENDS SQUARE CUT, TAPERED EDGES ON BOARDS TO BE FINISHED. 1. GYPSUM BOARD WALLS: EGGSHELL (SATIN) LATEX EMULSION. 2. AFTER CLEANING PROVIDE PROTECTIVE COVERING AND MAINTAIN CONDITIONS TO PROTECT
HARDWARE; MINIMUM ½” THICK GLASS. 2. TILE SUBSTRATE: CEMENTITIONS BACKER UNITS SPECIFIED IN SECTION 09300 - TILE. 2. GYPSUM BOARD CEILINGS: FLAT LATEX EMULSION. TILE WORK FROM DAMAGE OR DETERIORATION. WHERE TILED SURFACES WILL BE SUBJECT TO
1. EXPOSED METAL FINISH: NO. 4 SATIN DIRECTIONAL POLISHED STAINLESS STEEL. ARCH PROJECT NO.: 10835
H. GYPSUM BOARD ACCESSORIES: COMPLY WITH ASTM C840 3. WET ROOM WALLS AND CEILINGS: SEMI-GLOSS ACRYLIC ENAMEL. EQUIPMENT, WHEEL OR HEAVY CONSTRUCTION TRAFFIC, AND DURING THE MOVE-IN OF
NOT LESS THAN TYPE 304 FOR INTERIOR LOCATIONS, TYPE 316 FOR EXTERIOR FURNITURE AND EQUIPMENT, COVER PROTECTIVE COATING WITH ¼” HARDBOARD, PRODUCT SEASON: 2024
I. ACOUSTICAL ACCESSORIES: ASTM C665, TYPE I UNFACED ACOUSTICAL INSULATION, ASTM C919 4. PAINTED METAL: SEMI-GLOSS 100% ACRYLIC.
LOCATIONS OR AS PER ARCHITECT APPROVALS. ACOUSTICAL SEALANT AND OUTLET, SWITCH, AND TELEPHONE BOX ACOUSTICAL PADS. 5. OPAQUE PAINTED WOOD: SEMI-GLOSS 100% ACRYLIC. PLYWOOD OR SIMILAR MATERIAL. SPACE NO.: 185
E. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS AND APPLICABLE J. GYPSUM BOARD INSTALLATION: INSTALL IN ACCORDANCE WITH ASTM C840 AND MANUFACTURER'S 6. TRANSPARENT FINISHED WOOD: SATIN ACRYLIC URETHANE. 3. STONE TO BE SEALED WITH STONE MEDIC'S IMPREGNATOR O.R 2 COATS SEALER AS DRAWN BY: JTA
REQUIREMENTS FOR ACCESS FOR PERSONS WITH DISABILITIES. RECOMMENDATIONS; USE SCREWS WHEN FASTENING GYPSUM BOARD; COMPLY WITH GYPSUM L. PREPARATION AND APPLICATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS FOR TYPES OF SUBSTRATES AND RECOMMENDED BY THE MANUFACTURER. COORDINATE INSTRUCTIONS/INFORMATION WITH SCALE: AS NOTED
ASSOCIATION “LEVELS OF GYPSUM BOARD FINISH;” PROVIDE FIRE RATED SYSTEMS WHERE INDICATED. SPECIFIED PAINT SYSTEMS. SUPPLIERS TO BE SURE THAT THE INFORMATION IS CORRECT AND THAT THIS ACTION WILL
END OF SECTION 1. FINISH: GYPSUM ASSOCIATION LEVEL 5, THREE COAT FINISHING AND SANDING IS REQUIRED FOR GIVE US A FLOOR THAT LOOKS GOOD FOR A LONG PERIOD OF TIME.
SURFACES INDICATED TO BE PAINTED; PROVIDE FLUSH, SMOOTH JOINTS AND SURFACES READY FOR END OF SECTION 4. LEAVE FINISHED INSTALLATION CLEAN AND FREE OF CRACKED, CHIPPED, BROKEN, SHEET TITLE:
SECTION 08 42 29 - AUTOMATIC ENTRANCES PAINT FINISHES. UNBOUNDED, AND OTHERWISE DEFECTIVE TILE WORK.
K. ACOUSTICAL ACCESSORIES INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS AS SECTION 10 28 13 - TOILET ACCESSORIES 5. PROVIDE OWNER WITH 2 BOXED OF EACH COLOR TILE USED FOR ATTIC STOCK AT PROJECT
A. GENERAL: PROVIDE AUTOMATIC ENTRANCE SYSTEMS INCLUDING DOORS, FRAMES, REQUIRED TO ACHIEVE STC RATING INDICATED. COMPLETION. SPECIFICATIONS
OPERATORS, DETECTORS, AND ACCESSORIES AS REQUIRED FOR COMPLETE A. GENERAL: PROVIDE TOILET ACCESSORIES AS REQUIRED FOR COMPLETE FINISHED INSTALLATION.
OPERATIONAL WEATHERTIGHT INSTALLATION. END OF SECTION B. CODES AND REGULATIONS: COMPLY WITH STATE AND FEDERAL REQUIREMENTS FOR ENSURING ACCESS FOR PERSONS END OF SECTION
B. STANDARDS: COMPLY WITH ANSI/BHMA A156.10 POWER OPERATED PEDESTRIAN
DOORS.
C. MANUFACTURES: ACCESS TECHNOLOGIES - STANLEY WORKS/AUTO-SLIDE WITH
MAGIC-SCAN DETECTOR, DORMA - DOR-O-MATIC/ASTRO SLIDE, HORTON ELECTRIC
SECTION 09 30 00 - TILE

A. GENERAL: PROVIDE CERAMIC AND STONE TILE SYSTEMS INCLUDING SETTING MATERIALS, GROUT, AND
WITH DISABILITIES.
NOT USED
C. MANUFACTURERS: BOBRICK (PREFERED), BRADLEY, OR AMERICAN SPECIALTIES (ACCEPTABLE ALTERNATES)
D. TYPES: FLUSH MOUNTED TYPICAL FOR WALL MOUNTED UNITS; GRAB BARS AS REQUIRED BY APPLICABLE CODES AND
REGULATIONS.
DOCUMENT 00 70 00 - GENERAL CONDITIONS

SLIDE OR APPROVED EQUAL. ACCESSORIES AS REQUIRED FOR COMPLETE FINISHED INSTALLATION. A. GENERAL CONDITIONS: THE GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION, AIA

THE MALL AT WELLINGTON GREEN


E. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS AND APPLICABLE CODES AND REGULATIONS.
DOCUMENTS A201, 2017 EDITION, IS A PART OF THIS CONTRACT, AND SHALL GOVERN WORK.

STORE NO. US 326 - RED MOD


D. TYPE: EXTRUDED ALUMINUM AND GLASS AUTOMATIC (ELECTRO-MECHANICAL) SLIDING B. STANDARDS: COMPLY WITH TILE COUNCIL OF NORTH AMERICAN “HANDBOOK OF CERAMIC TILE

BLVD.WELLINGTON, FL. 33414


DOOR SYSTEMS TO MATCH ALUMINUM ENTRANCES AND STOREFRONTS; OPERATION INSTALLATION” INCLUDING REFERENCED ASTM AND ANSI STANDARDS. END OF SECTION A COPY WILL BE MADE AVAILABLE BY ARCHITECT UPON REQUEST.

10300 W. FOREST HILL


BY MOTION DETECTOR, WITH RELATED TRIM AND FLUSH GLAZING. C. TILE: TYPES AS INDICATED ON FINISH SCHEDULE.
1. FINISH: MATCH ALUMINUM WINDOWS. 1. OWNER FURNISHED TILE: COORDINATE DIRECTLY WITH OWNER. END OF SECTION
2. PANIC DEVICE: PROVIDE EMERGENCY BREAKAWAY SWING FEATURE WITH 2. MARBLE SADDLES: HONED FINISH, PREMIUM GRADE VERMONT OR GEORGIA WHITE MARBLE AS SECTION 10 14 00 - SIGNAGE
SELF-CLOSING FEATURE, SAFETY RELEASE CLUTCH FOR OBSTRUCTED CLOSING, APPROVED BY ARCHITECT, FREE OF CRACKS, FLAWS, AND DEFECTS; COMPLY WITH APPLICABLE
AND ELECTRICAL INTERLOCK TO PREVENT OPERATION WHEN DOORS ARE LOCKED. STATE AND FEDERAL REQUIREMENTS FOR ACCESS FOR CONNECTION OF ADJACENT FLOOR A. GENERAL: PROVIDE GENERAL SIGNAGE INCLUDING ENTRY SIGNS, TOILET ROOM SIGNS, STAIR SIGNS AND BRAILLE EXIT SECTION 01 11 00 SUMMARY OF WORK

2024
E. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS AND ANSI/BHMA FINISHES. SIGNS AS REQUIRED BY APPLICABLE CODES AND STANDARDS.
3. FLOOR TILE: PROVIDE NON-SLIP UNITS WITH MINIMUM WET AND DRY VALUE COEFFICIENT OF B. CODES AND REGULATIONS: COMPLY WITH STATE AND FEDERAL REQUIREMENTS FOR ENSURING ACCESS FOR PERSONS A. SCOPE: PROJECT CONSISTS OF CONSTRUCTION OF H&M STORE AS INDICATED IN CONTRACT
END OF SECTION FRICTION OF NOT LESS THAN 0.60, ASTM C1028. WITH DISABILITIES. DOCUMENTS.
D. LATEX THIN SET: THIN SET BOND COAT, LATEX-CEMENTITIOUS MORTAR CONFORMING TO ANSI A118.4. C. MANUFACTURERS: ASI SIGN, MOHAWK, VOMAR, OR CAMEO. 1. ITEMS NOTED “NIC” (NOT IN CONTRACT) WILL BE FURNISHED AND INSTALLED BY OWNER
E. GROUT: MAPEI OR LATICRETE SPECTRALOCK PRO EPOXY GROUT, UNIFORM IN COLOR, RESISTANT TO D. ENTRY SIGNS: VINYL PRESSURE SENSITIVE SIGNS. UNDER SEPARATE CONTACT.
SHRINKAGE, COLOR TO BE PER FINISH SCHEDULE. E. TOILET ROOM DOOR SIGNS: PLASTIC; TWO SIGNS REQUIRED FOR EACH TOILET ROOM, ONE SIGN ON THE DOOR TO
F. WATERPROOF MEMBRANE: LATICRETE, BOSTIK, MER-KOTE, OR NOBEL; MANUFACTURER'S STANDARD B. WORK SEQUENCE: COORDINATE CONSTRUCTION SCHEDULE, OPERATIONS AND USE OF PREMISES
COMPLY WITH REQUIREMENTS, ONE SIGN ADJACENT TO DOOR TO COMPLY WITH ADAAG; WITH BRAILLE.
SYSTEM DESIGNED FOR APPLICATION UNDER THIN SET TILE IN NON-IMMERSED APPLICATIONS. WITH ARCHITECT AND OWNER.
F. STAIR SIGNAGE: PLASTIC WITH APPLIED COPY, VINYL LETTERS OR SILKSCREENED, AND BRAILLE.
G.CEMENTITIOUS BACKER UNITS: ANSI A118.9, NOMINAL ½” THICKNESS UNLESS OTHERWISE INDICATED G.BRAILLE EXIT SIGNS: PLASTIC. C. CONTRACTOR USE OF PREMISES: LIMIT TO AREAS INDICATED ON DRAWINGS AND AS SPECIFIED;
OR REQUIRED FOR FIRE RATINGS; USG/DUROCK, NATIONAL GYPSUM/PERMABASE, OR CUSTOM H. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS AND APPLICABLE CODES AND REGULATIONS. LIMIT ACCESS AS DIRECTED BY OWNER.
BUILDING PRODUCTS/WONDERBOARD. D. BUILDING OCCUPANCY: OTHER AREAS MAY BE OCCUPIED DURING CONSTRUCTION; COOPERATE
H. CLEANING AND SEALING MATERIALS: AS RECOMMENDED BY TILE AND GROUT MANUFACTURERS, SUCH END OF SECTION WITH OWNER TO MINIMIZE CONFLICT AND TO FACILITATE BUILDING OPERATIONS.
AS BOSTIK CONSTRUCTION PRODUCTS/HYDROMENT CERAMA SEAL. E. LINE AND LEVELS: PROVIDE FIELD MEASUREMENTS; ESTABLISH LINES AND LEVELS BY USE OF
I. PREPARATION: DO NOT COMMENCE WORK UNTIL CONDITIONS ARE WITHIN TOLERANCES REQUIRED SECTION 10 51 00 - LOCKERS RECOGNIZED ENGINEERING PRACTICES. LOCATE AND PROTECT CONTROL AND REFERENCE POINTS. SHEET NO:

A-930
FOR INSTALLATION; APPLY LATEX LEVELING MATERIAL WHERE NECESSARY TO MEET REQUIRED F. REGULATORY REQUIREMENTS: PROJECT HAS BEEN DESIGNED IN ACCORDANCE WITH APPLICABLE
TOLERANCES. A. GENERAL: PROVIDE METAL LOCKERS WITH ACCESSORIES AS REQUIRED FOR COMPLETE FINISHED INSTALLATION. CODES. COMPLY WITH CODE REQUIREMENTS FOR CONSTRUCTION. INFORM ARCHITECT OF
J. WATERPROOFING: INSTALL WATERPROOFING AT TILE AREAS LOCATED ABOVE GRAND IN ACCORDANCE B. MANUFACTURERS: LOCK UP - POLYCARBONATE. STYLE - RED 3 OR 6 TIER. DISCREPANCIES OBSERVED OR NOTED BY OTHERS.

NOT USED
WITH MANUFACTURER'S RECOMMENDATIONS; EXTEND MEMBRANE MINIMUM 6” UP WALLS. C. TYPE: STANDARD TRIPLE TIER LOCKERS WITH FLAT TOPS AND “Z” TYPE RECESSED METAL BASES; PROVIDE LOCKUP LOCKS G.STANDARDS: COMPLY WITH STANDARDS REFERENCED EXCEPT WHERE MORE RIGID
K. CEMENTITIOUS BACKER UNITS: INSTALL UNITS IN ACCORDANCE WITH ANSI A108.11, MANUFACTURER BY DIGILOCK; H&M COLORS AS SELECTED. (RED) REQUIREMENTS ARE REQUIRED BY CODE. DATE OF STANDARD IS THAT IN EFFECT AS OF DATE
RECOMMENDATIONS, AND AS REQUIRED TO PROVIDE FIRE RATINGS INDICATED ON DRAWINGS. D. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS. DOCUMENTS ARE ISSUED, EXCEPT WHEN SPECIFIC DATE IS SPECIFIED.
L. TILE INSTALLATION: INSTALL TILE IN ACCORDANCE WITH REFERENCES ANSI STANDARDS AND TCA REV. NO:
H. OWNER FURNISHED CONTRACTOR INSTALLED ITEMS: OWNER WILL ARRANGE FOR AND PAY FOR
RECOMMENDATIONS FOR TYPE OF SUBSTRATE AND INDICATED SETTING METHOD; LATEX-CEMENT THIN END OF SECTION PRODUCT AS INDICATED ON DRAWINGS TO BE DELIVERED TO PROJECT SITE FOR CONTRACTOR
SET AND BOND COATS REQUIRED. INSTALLATION.
1. THIN SET APPLICATIONS: LATEX BOND COAT. 1. CONTRACTOR SHALL INSPECT, RECEIVE, UNLOAD, STORE INSTALL AND FINISH.
2. PLACE TILE IN ACCORDANCE WITH PATTERNS INDICATED ON DRAWINGS OR AS DIRECTED BY
ARCHITECT; CAREFULLY PLAN TILE LAYOUTS, ENSURE PATTERN IS UNINTERRUPTED FROM ONE
SURFACE TO THE NEXT AND THROUGH DOORWAYS. END OF SECTION
D.O.B. NO:
3. CLEAN AND SEAL TILE AND GROUT SURFACES WHERE RECOMMENDED BY MANUFACTURER FOR
MATERIALS AND APPLICATIONS INVOLVED; COMPLY WITH MANUFACTURER'S RECOMMENDATIONS.
4. PROVIDE ANTI-FRACTURE MEMBRANE: MAPILASTIC C1 OR APPROVED EQUAL. ONLY AS PER
INSTALLERS RECOMMENDATIONS.

END OF SECTION
SECTION 01 30 00 - ADMINISTRATIVE REQUIREMENTS SECTION 01 60 00 - PRODUCT REQUIREMENTS SECTION 01735 - SELECTIVE DEMOLITION FOR REMODELING GENERAL: SECTION 09 28 00 - CEMENTITIOUS UNDERLAYMENT GENERAL

A.PROCEDURES: CONTRACTOR SHALL REVIEW AND APPROVE SUBMITTALS PRIOR TO A. MATERIALS AND EQUIPMENT SHALL BE NEW AND OF TYPE INTENDED FOR USAGE A.REMOVE FROM SITE EXISTING MATERIALS, CONSTRUCTION AND UTILITIES AS NEEDED TO PROVIDE POURED CEMENTITIOUS UNDERLAYMENT SYSTEM, NOT INTENDED AS FINISHED
SUBMITTING TO ARCHITECT. INFORM ARCHITECT IN WRITING AT SUBMISSION OF INDICATED. LIKE COMPONENTS SHALL BE BY ONE MANUFACTURER AND COMPONENT COMPLETE PROJECT. TRAFFIC SURFACE, INCLUDING ACCESSORIES AS REQUIRED FOR COMPLETE INSTALLATION.
PROPOSED DEVIATIONS FROM CONTRACT DOCUMENTS. PART SHALL BE INTERCHANGEABLE. A.INSTALLER: FIRM WITH MINIMUM FIRE YEARS SUCCESSFUL EXPERIENCE, REGULARLY
1. REMOVE EXISTING ELEMENTS INDICATED AND ENCOUNTERED DURING CONSTRUCTION,
1. SUBMITTAL REPRESENTS FIELD MEASUREMENTS, FIELD CONSTRUCTION CRITERIA, AS NEEDED TO COMPLETE WORK. ENGAGED IN INSTALLATION OF SPECIFIED MATERIALS, PROPERLY EQUIPPED AND
B. SUBMITTALS: SUBMIT COMPLETE LIST OF PRODUCTS BEING PROPOSED FOR
MATERIALS, CATALOG NUMBERS AND SIMILAR DATA HAVE BEEN DETERMINED ACCEPTABLE TO MANUFACTURER.
INSTALLATION TABULATED BY SPECIFICATION NUMBER AND TITLE.
AND VERIFIED BY CONTRACTOR. 2. REMOVE ONLY THOSE ELEMENTS NECESSARY FOR COMPLETION OF PROJECT, REPLACE
OR REPAIR ELEMENTS UNNECESSARILY REMOVED OR DAMAGED DURING B. TROWEL APPLIED SYSTEM: BY MAPEI OR LATICRETE, CAPABLE OF RECEIVING FEATHER
C. QUALITY ASSURANCE: COMPLY WITH INDUSTRY STANDARDS EXCEPT WHEN MORE
2. REVIEW OF SUBMITTALS BY ARCHITECT SHALL BE FOR DESIGN CONCEPT ONLY CONSTRUCTION. EDGE TO EXISTING FLOOR; 4000 PSI COMPRESSIVE STRENGTH AT 28 DAYS.
STRINGENT TOLERANCE ARE REQUIRED. PERFORM WORK BY PERSONS QUALIFIED TO
AND SHALL NOT BE CONSTRUED AS APPROVING DEPARTURES FROM PRODUCE WORKMANSHIP OF SPECIFIED QUALITY. 3. CAREFULLY REMOVE AND STORE ITEMS INDICATED FOR REUSE IN PROJECT AND C. SELF-LEVELING SYSTEM: BY MAPEI OR LATICRETE HIGH-STRENGTH, FAST-SETTING, JEFFREY
CONTRACT DOCUMENTS. NON-SHRINK, SELF-LEVELING UNDERLAYMENT; 4000 PSI COMPRESSIVE STRENGTH AT
B. CONSTRUCTION PROGRESS SCHEDULE: SUBMIT BOTH BAR CHARTS AND
1. ANCHORS: SECURE PRODUCTS IN PLACE WITH POSITIVE ANCHORAGE DEVICES
DESIGNED AND SIZED TO WITHSTAND STRESSES, VIBRATION AND RACKING,
COORDINATE WITH OTHER TRADES FOR MODIFICATIONS AND REINSTALLATION.
28 DAYS. TAYLOR
CONTRACTOR'S STANDARD COMPUTERIZED SCHEDULES, UPDATED REGULARLY, NO 4. COORDINATE REMOVAL AND STORAGE OF MATERIALS AS INDICATED AND AS DIRECTED
INCLUDING SEISMIC LOADS.
FOR OWNER'S MAINTENANCE STOCK; DELIVER TO LOCATION ON SITE AS DIRECTED BY D. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS AND ARCHITECT
LESS THAN MONTHLY. INSTALLATION INSTRUCTION FOR EACH TYPE OF UNDERLAYMENT, TROWEL APPLIED
D. DELIVERY, STORAGE AND HANDLING: TRANSPORT, HANDLE, STORE, PROTECT AND OWNER.
C. SCHEDULE OF VALUES: AIA FORM G703 OR APPROVED FORMAT. FOR FEATHER EDGE AND SELF-LEVELING.
INSTALL MANUFACTURED ITEMS IN STRICT ACCORDANCE WITH MANUFACTURER'S B. PROTECTION: PREVENT MOVEMENT AND SETTLEMENT OF ADJACENT STRUCTURE; PROVIDE
RECOMMENDATIONS. 572 NORTH BROADWAY
D. SHOP DRAWINGS: SUBMIT FOR PRINTS; PROVIDE FOR CUSTOM PRODUCTS AND BRACING,SHORING, AND UNDER PIPING AS NEEDED AND BE RESPONSIBLE FOR SAFETY AND
END OF SECTION WHITE PLAINS, NEW YORK 10603
PRODUCTS NOT FULLY IDENTIFIED BY PRODUCT DATA. 1. SHOULD CONFLICT EXIST BETWEEN CONSTRUCTION DOCUMENTS AND SUPPORT OF STRUCTURES.
E. SHOP DRAWINGS REQUIRED: STOREFRONT, GLASS RAILS, DOOR AND HARDWARE, MANUFACTURER'S INSTRUCTIONS, CONSULT WITH ARCHITECT. 1. ASSUME LIABILITY FOR SUCH MOVEMENT AND SETTLEMENT TEL 914 289 0011
SCHEDULE, CABINET WORK, LOCKERS, FLOORING, SUSPENDED CEILING, HVAC 2. STORE AND PROTECT PRODUCTS AND FINISHES FROM DAMAGE FROM SECTION 05 50 00 METAL FABRICATIONS
(FIXTURES, CONTROLS AND AIR BALANCE), PLUMBING FIXTURES, ELECTRICAL C. UTILITIES: CONTACT APPLICABLE UTILITY COMPANIES PRIOR TO DISCONNECTING UTILITIES;
CONSTRUCTION OPERATIONS; COMPLY WITH MANUFACTURER DISCONTINUE WORK IF UNEXPECTED UTILITY LINES ARE ENCOUNTERED.
(SWITCHGEAR AND LIGHTS), FIRE ALARM, FIRE SPRINKLERS. THIS IS A BASIC MINIMUM RECOMMENDATIONS.
LIST, SUBMIT OTHERS AS DEEMED NECESSARY. A. GENERAL: PROVIDE MISCELLANEOUS METAL SHAPES AND FABRICATIONS AS REQUIRED
1. DETERMINE LINE SOURCE AND USE PRIOR TO REMOVAL
AND NOT INCLUDED AS PART OF OTHER SECTIONS WITH ANCHORS AND
F. PRODUCT DATA: SUBMIT NUMBER REQUIRED BY CONTRACTOR PLUS TWO FOR END OF SECTION 2. CAP AND IDENTIFY EXISTING UTILITY LINES REMOVED ACCESSORIES FOR COMPLETE INSTALLATION.
ARCHITECT; INDICATE ITEM TO BE USED WHERE DATA FOR MORE THAN ONE PRODUCT
OR OPTION IS INCLUDED; PROVIDE FOR EACH STOCK MANUFACTURED ITEM. D. PROCEDURES: SELECTIVELY REMOVE EXISTING CONSTRUCTION IN AN ORDERLY, CAREFUL, AND B. STEEL SHAPES: ASTM A36 STEEL.
SECTION 01 25 00 - PRODUCT SUBSTITUTION PROCEDURES SAFE MANNER, IN ACCORDANCE WITH AUTHORITIES HAVING JURISDICTION.
G.SAMPLES: SUBMIT SAMPLES FOR EACH TYPE OF EXPOSED FINISH, COLOR, AND C. GROUT: PROVIDE NON-SHRINK, NON-METALLIC, PRE-MIXED, FACTORY PACKAGED,
TEXTURE, MINIMUM SIZE 6”, MAXIMUM SIZE 12” UNLESS OTHERWISE SPECIFIED; SUBMIT 1. USE METHODS WHICH DO NOT DAMAGE MATERIALS INDICATED TO REMAIN NON-STAINING, NON-CORROSIVE, NON-GASEOUS GROUT; TYPE SPECIFICALLY
ONE SAMPLE FOR ARCHITECT TO RETAIN, ONE SAMPLE FOR FIELD OFFICE AND NUMBER RECOMMENDED BY MANUFACTURER FOR APPLICATIONS INDICATED.
A. SUMMARY: PROVIDE PRODUCTS INDICATED OR APPROVED; REQUESTS FOR 2. TAKE PRECAUTIONS AS REQUIRED TO PREVENT UNNECESSARY DUST AND POLLUTION
REQUIRED BY CONTRACTOR. SUBSTITUTION OF OTHER PRODUCTS WILL BE CONSIDERED IF SUBMITTED IN WRITING. D. GENERAL FABRICATION: GRIND EXPOSED WELDS SMOOTH AND FLUSH WITH
3. REMOVE DEMOLISHED MATERIALS FROM SITE UNLESS OTHERWISE DIRECTED; DISPOSE OF
H. MANUFACTURER'S CERTIFICATES: PROVIDE THREE. ADJACENT SURFACES; COUNTERSINK FASTENERS; MAKE EXPOSED BUTT JOINTS
B. CONTRACTOR OPTIONS: PROVIDE PRODUCTS AND MANUFACTURERS NAMED IN IN ACCORDANCE WITH APPLICABLE CODES
HAIRLINE JOINTS WHERE MECHANICALLY FASTENED, FIT AND SHOP ASSEMBLE IN
SPECIFICATIONS, SUBMIT REQUEST FOR SUBSTITUTION FOR PRODUCTS AND
LARGEST PRACTICAL SECTIONS FOR DELIVERY.
MANUFACTURERS NOT SPECIFICALLY NAMED WHERE NAMES ARE LISTED.
END OF SECTION

SECTION 01 31 00 - PROJECT MANAGEMENT AND COORDINATION


C. SUBSTITUTIONS: CONTRACTOR SHALL INVESTIGATE PROPOSED SUBSTITUTIONS AND
DETERMINE IF EQUIVALENT TO PRODUCTS SPECIFIED.
1. SUBMITTALS SHALL INCLUDE COST OR TIME BENEFITS FOR SUBSTITUTIONS;
END OF SECTION

SECTION 01 77 00 - CLOSEOUT PROCEDURES


NOT USED
E. STEEL RAILINGS: WHERE LOCATED ON DRAWINGS PROVIDE WELDED TYPE WITH
1-1/2” OUTSIDE DIAMETER TUBE HANDRAILS; DESIGNED TO SUPPORT MINIMUM
LATERAL FORCE OF 50 LBS/LIN FT UNIFORM LOAD AND 200 LBS AT ANY POINT
WITHOUT PERMANENT SET OR DAMAGE.
LIC # AR0015561

FAILURE TO INDICATE COST OF TIME BENEFIT IS JUSTIFICATION FOR REJECTION.


A. COORDINATION: COORDINATE WORK OF VARIOUS TRADES; VERIFY CHARACTERISTICS A. SUBSTANTIAL COMPLETION: PROVIDE DOCUMENTATION STATING WORK HAS BEEN 1. STANDARDS: COMPLY WITH STATE AND FEDERAL REQUIREMENTS FOR ACCESS
OF INTERRELATED OPERATING EQUIPMENT ARE COMPATIBLE. D. CONTRACTOR'S REPRESENTATION: REQUESTS CONSTITUTE THAT CONTACTOR HAS SUBSTANTIALLY COMPLETED. WHERE OWNER REQUIRED USE OF SPACE PRIOR TO FINAL FOR PERSONS WITH DISABILITIES AND WITH NAAMM “PIPE RAILING MANUAL”
INVESTIGATED PROPOSED PRODUCTS AND DETERMINES IT MEETS OR EXCEEDS
1. COORDINATE WORK HAVING INTERDEPENDENT RESPONSIBILITIES FOR COMPLETION, PROVIDE LIST OF ITEMS TO BE COMPLETED. F. PRE-ENGINEERED SUPPORT SYSTEM: UNISTRUT OR GRINNELL/POWERSTRUT
SPECIFIED PRODUCTS AND WAIVES CLAIMS FOR ADDITIONAL COSTS THAT
INSTALLING CONNECTION TO AND PLACING IN SERVICE. SUBSEQUENTLY BECOME APPARENT. 1. ARCHITECT WILL REVIEW LIST OF ANY ITEMS TO BE COMPLETED AND SUPPLEMENT LIST MANUFACTURED PRE-ENGINEERED SUPPORT SYSTEM CONSISTING OF MINIMUM 12
WITH ITEMS CONSIDERED TO BE INCOMPLETE OR UNACCEPTABLE. GAGE “C” CHANNEL SUPPORTS WITH ANCHORS, ATTACHMENTS, AND ACCESSORIES
B. SUBMITTALS: PREPARE COORDINATION DRAWINGS FOR AREAS WHERE SPACE E. ARCHITECT'S DUTIES: ARCHITECT SHALL BE JUDGE OF ACCEPTABILITY AND RESERVES AS REQUIRED FOR COMPLETE INSTALLATION.
AVAILABILITY IS LIMITED AND NECESSITATES MAXIMUM UTILIZATION OF SPACE, AND RIGHT TO REJECT PROPOSED SUBSTITUTION BASED ON INSUFFICIENT INFORMATION; B. FINAL COMPLETION: SUBMIT CERTIFICATION WORK IS IN COMPLIANCE WITH CONTRACT
WHERE SEPARATE ENTITIES, PRODUCTS, AND MATERIALS REQUIRE COORDINATION. USE ONLY SUBSTITUTION APPROVED IN WRITING. DOCUMENTS, SYSTEMS HAVE BEEN TESTED AND ARE OPERATIONAL, AND WORK IS READY FOR G.FINISH: PRIME PAINT MISCELLANEOUS METAL. CLEAN SURFACES OR RUST, SCALE,
FINAL INSPECTION. GREASE AND FOREIGN MATTER PRIOR TO APPLYING GALVANIZED OR PAINTED FINISH.
C. SUPERVISORY PERSONNEL: PROVIDE SUPERVISORY PERSONNEL IN ADDITION TO
PROJECT SUPERINTENDENT; SUBMIT LIST OF STAFF NAMES AND POST COPIES IN C. RECORDS AND DOCUMENTS: MAINTAIN COMPLETE AND UP-TO-DATE RECORD DOCUMENTS; H. INSTALLATION: INSTALL SQUARE AND LEVEL, ACCURATELY FITTED AND FREE FROM EXP. 2/28/2025
PROJECT MEETING ROOM. END OF SECTION DISTORTION AND DEFECTS.
KEEP SEPARATE FROM FIELD DOCUMENTS; OWNER WILL FURNISH SET FOR RECORD DRAWINGS.
D. PROJECT MEETINGS: SCHEDULE AND ADMINISTER MEETINGS, MAKE PHYSICAL D. DATA: SUBMIT PROJECT RECORD DOCUMENTS, MATERIAL AND FINISH DATA, OPERATION AND REVISION:
ARRANGEMENT, PREPARE AGENDA, PRESIDE AT MEETINGS AND RECORD MINUTES. SECTION 01 70 00 EXECUTION AND CLOSEOUT REQUIREMENTS INSTRUCTION MANUALS, WARRANTIES AND BONDS AT COMPLETION; SUBMIT IN END OF SECTION
COMPUTERIZED COMPACT DISK (CD'S) WHERE AVAILABLE.
END OF SECTION A.INSTALLER QUALIFICATIONS: INSTALLERS TO HAVE MINIMUM FIVE YEARS SUCCESSFUL 1. SUBMIT BOUND IN 8-1/2” BY 11” THREE RING BINDERS WITH DURABLE PLASTIC COVERS. SECTION 05 73 00 STAINLESS STEEL AND GLASS RAILINGS
EXPERIENCE INSTALLING ITEMS SIMILAR TO THOSE REQUIRED FOR PROJECT, EXCEPT ARRANGE IN FORMAT SIMILAR TO SPECIFICATIONS
FOR INDIVIDUALS IN TRAINING UNDER DIRECT SUPERVISION OF EXPERIENCED
SECTION 01 40 00 - QUALITY REQUIREMENTS INSTALLER. A. GENERAL: PROVIDE STAINLESS STEEL AND GLASS RAILING WITH STAINLESS STEEL
END OF SECTION POSTS, RAILS AND COMPONENTS, ATTACHMENTS AND ACCESSORIES AS REQUIRED
B. EXAMINATION: BEGINNING INSTALLATION OF A PRODUCT SIGNIFIES INSTALLER HAS FOR COMPLETE FINISHED INSTALLATION.
A. GENERAL: MAINTAIN QUALITY CONTROL OVER SUPPLIERS, MANUFACTURERS, EXAMINED SUBSTRATES, AREAS, AND CONDITIONS FOR COMPLIANCE WITH
PRODUCTS, SERVICES, SITE CONDITIONS AND WORKMANSHIP. MANUFACTURER REQUIREMENTS FOR TOLERANCES AND OTHER CONDITION SECTION 01 78 36 - WARRANTIES B. QUALITY ASSURANCE: DESIGN TO SUPPORT MINIMUM LATERAL FORCE OF 50LBS/LIN
AFFECTING PERFORMANCE. FT UNIFORM LOAD AND 200 LBS AT ANY POINT WITHOUT PERMANENT SET OR
B. MANUFACTURER'S FIELD SERVICES: PROVIDE MANUFACTURER OR SUPPLIER QUALIFIED DAMAGE. ISSUE DATE:
PERSONNEL FOR ON-SITE OBSERVATIONS AS REQUIRED. C. MANUFACTURER'S INSTRUCTIONS: WHEN WORK IS SPECIFIED TO COMPLY WITH A. WARRANTIES: PROVIDE WARRANTIES AS INDICATED, SIGNED BY CONTRACTOR AND 06.12.23 FOR REVIEW & APPROVALS
MANUFACTURER'S RECOMMENDATIONS OR INSTRUCTION, DISTRIBUTE COPIES TO MANUFACTURER; FORM AS APPROVED BY OWNER PRIOR TO EXECUTION. C. CODES AND REGULATIONS: COMPLY WITH STATE AND FEDERAL REQUIREMENTS FOR
C. MOCK-UPS: CONSTRUCT FIELD SAMPLES AND MOCK-UPS ON SITE AS REQUIRED. ENSURING ACCESS FOR PERSONS WITH DISABILITIES. 07.17.23 FOR BIDS & PERMITS
PERSONS INVOLVED, AND MAINTAIN ONE SET IN FIELD OFFICE. 1. WARRANTIES SHALL BE IN ADDITION TO AND NOT A LIMITATION OF OTHER RIGHTS
D. TESTING LABORATORY SERVICES: WHERE REQUIRED BY APPLICABLE AUTHORITIES D. STAINLESS STEEL COMPONENTS: ASTM A269, GRADE 304; NUMBER [4], BRUSHED
D. INSTALLATION: COMPLY WITH MANUFACTURER'S WRITTEN RECOMMENDATIONS AND OWNER MAY HAVE AGAINST CONTRACTOR UNDER CONTRACT DOCUMENTS AND

NOT USED
PROJECT TESTING SHALL BE AN APPROVED TESTING LABORATORY, AS REQUIRED BY FINISH OR NUMBER [8] POLISHED STAINLESS STEEL AS NOTED IN DETAILS, FINISH AS
SPECIFICATIONS AND APPLICABLE CODES. INSTALLATION INSTRUCTION UNLESS MORE RESTRICTIVE REQUIREMENTS ARE SPECIFIED. PRESCRIBED BY LAW, REGARDLESS OF WORDING OF WARRANTY.
DEFINED IN NAMM'S METAL FINISHED MANUAL.
1. TESTING REQUIRED FOR PROJECT WILL BE PAID FOR BY OWNER EXCEPT E. FINAL CLEANING: CLEAN INTERIOR AND EXTERIOR SURFACES EXPOSED TO VIEW, B. LIMITATIONS: WARRANTIES NEED NOT COVER FAILURES FROM UNUSUAL OR ABNORMAL
REMOVE TEMPORARY LABELS, STAINS, AND FOREIGN SUBSTANCES; POLISH PHENOMENA OF THE ELEMENTS, OWNER'S MISUSE, MALTREATMENT OR IMPROPER E. GLASS: ASTM C1048, KIND FT, FULLY TEMPERED SELECT GLAZING QUALITY CLEAR
RETESTING WILL BE PAID FOR BY CONTRACTOR WHERE REQUIRED BY FAILURE FLOAT GLASS WITH NO EXPOSED TONG OR STRESS MARKS; NOMINAL ¾” THICK
TO MEET ORIGINAL TESTS. TRANSPARENT AND GLOSSY SURFACES; VACUUM CARPETED AND SOFT SURFACES; MAINTENANCE WORK, VANDALISM AFTER SUBSTANTIAL COMPLETION, OR WAR.
CLEAN DUCTS; CLEAN SITE. UNLESS OTHERWISE INDICATED; SAFETY GLASS PASSING ANSI Z97.1 AND
2. CONTRACTOR SHALL FURNISH MATERIALS AND SAMPLES FOR TEST AND SHALL ACCEPTABLE TO AUTHORITIES FOR USE IN RAILINGS.
ASSIST TESTING LABORATORY AS REQUESTED. F. PROTECTION: COVER PRODUCTS SUBJECT TO DETERIORATION WITH IMPERVIOUS END OF SECTION ARCH PROJECT NO.: 10835
SHEET COVERING, PROVIDE VENTILATION TO AVOID CONDENSATION AND TRAPPING F. GROUT: PROVIDE NON-SHRINK, NON-METALLIC, PRE-MIXED, FACTORY PACKAGED,
NON-STAINING, NON-CORROSIVE, NON-GASEOUS GROUT; TYPE SPECIFICALLY PRODUCT SEASON: 2024
WATER. SPACE NO.: 185
END OF SECTION SECTION 01 79 00 - SYSTEM DEMONSTRATIONS RECOMMENDED BY MANUFACTURER FOR APPLICATIONS INDICATED.
DRAWN BY: JTA
G.FABRICATION: CONCEAL WELDS AND CONNECTIONS, PROVIDE HAIRLINE JOINTS.
END OF SECTION SCALE: AS NOTED
SECTION 01 50 00 - TEMPORARY FACILITIES AND CONTROLS A. SUMMARY: PROJECT INCLUDES SPECIAL FACILITY START-UP PROCESS TO BRING FACILITY TO ENSURE THAT ALL JOINTS ARE WELDED, POLISHED, AND SEALED.
FULLY OPERATIONAL STATE, FREE OF DEFICIENCIES, IN MOST EFFICIENT AND TIMELY MANNER H. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS.
SECTION 01 73 29 CUTTING AND PATCHING ACHIEVABLE.
SHEET TITLE:
A. TEMPORARY SERVICES: PROVIDE TEMPORARY ELECTRICITY, LIGHTING, HEAT AND
VENTILATION, WATER, SANITARY FACILITIES, ENCLOSURES, AND BARRIERS AS REQUIRED END OF SECTION
A. CUTTING AND PATCHING: CUT AND FIT COMPONENTS AS REQUIRED; PATCH END OF SECTION
BY AUTHORITIES AND AS REQUIRED TO COMPLETE PROJECT. DISTURBED AREAS TO MATCH ADJACENT MATERIALS AND FINISHED. SPECIFICATIONS
1. COORDINATE AVAILABILITY OF EXISTING SERVICES WITH OWNER; DO NOT USE SECTION 06 00 00 - MISCELLANEOUS ROUGH CARPENTRY
1. MAKE PARTS FIT TOGETHER PROPERLY
SERVICES WITHOUT PRIOR OWNER WRITTEN APPROVAL. SECTION 03 11 16 - CAST-IN-PLACE CONCRETE
2. UNCOVER WORK TO PROVIDE FOR INSTALLATION OF ILL-TIME WORK
B. CONSTRUCTION AIDS: MAINTAIN NOISE, DUST AND POLLUTION CONTROL, SECURITY A. GENERAL: PROVIDE MISCELLANEOUS BLOCKING AND PLYWOOD.
AND FIRE PROTECTION. 3. REMOVE AND REPLACE DEFECTIVE WORK A. GENERAL: PROVIDE FORMWORK, REINFORCING, AND CAST-IN-PLACE CONCRETE AS REQUIRED
B. STANDARDS: COMPLY WITH AMERICAN INSTITUTE OF TIMBER CONSTRUCTION (AITC),
C. ENCLOSURES: PROVIDE TEMPORARY WEATHER-TIGHT CLOSURES FOR EXTERIOR 4. REMOVE AND REPLACE WORK NOT CONFORMING TO CONTRACT TO COMPLETE PROJECT AS INDICATED, TO COMPLY WITH STRUCTURAL DRAWINGS,
AMERICAN PLYWOOD ASSOCIATION (APA), AND APPLICABLE CODE REQUIREMENTS.
REQUIREMENTS OF ACI, AND APPLICABLE CODES.

THE MALL AT WELLINGTON GREEN


OPENING TO MAINTAIN ACCEPTABLE WORKING CONDITIONS, FOR PROTECTION OF DOCUMENTS
C. BLOCKING: COMPLY WITH PS 20; GRADED BY AN AGENCY CERTIFIED BY FOREST

STORE NO. US 326 - RED MOD

BLVD.WELLINGTON, FL. 33414


MATERIALS, TEMPORARY HEATING, AND TO PREVENT UNAUTHORIZED ENTRY. 5. REMOVE SAMPLES OF INSTALLED WORK AS REQUIRED FOR TESTING 1. SLAB-ON-GRADE VAPOR RETARDER IS IN SECTION 07260
PRODUCTS SOCIETY (FPS) AND TYPE RECOMMENDED FOR APPLICATION INVOLVED;
D. BARRIERS: PROVIDE AS REQUIRED TO PREVENT UNAUTHORIZED ENTRY, TO PROTECT B. STANDARDS: COMPLY WITH APPLICABLE BUILDING CODE, AMERICAN CONCRETE INSTITUTE (ACI) DOUGLAS FIR OR SOUTHERN PINE; MINIMUM CONSTRUCTION GRADE S-DRY.

10300 W. FOREST HILL


6. PROVIDE ROUTINE PENETRATION OF NON-STRUCTURAL SURFACES,
ADJACENT PROPERTIES, AND AS REQUIRED BY GOVERNING AUTHORITIES. AND CONCRETE REINFORCING STEEL INSTITUTE (CRSI) STANDARDS AS APPLICABLE.
B. REFINISHING: REFINISH ENTIRE SURFACES AS NECESSARY TO PROVIDE EVEN FINISH TO D. PLYWOOD: COMPLY WITH PS 1, AND APPLICABLE APA PERFORMANCE STANDARDS
E. CLEANING DURING CONSTRUCTION: PROVIDE PERIODIC CLEANING DURING MATH ADJACENT FINISHES; FOR CONTINUOUS SURFACES REFINISH TO NEAREST C. FORMWORK: ACI 347; PROVIDE NON-BONDING AND NON-STAINING FORM SEALERS. FOR TYPE OF PANEL AND APPLICATION INDICATED.
PROGRESS OF WORK. INTERSECTION, FOR AN ASSEMBLY REFINISH ENTIRE UNIT. D. REINFORCING: COMPLY WITH ACI 315 AND 318, CRSI 59 AND 63, AND AWI D12.1; ASTM E. TREATED WOOD: PRESSURE TREAT WOOD IN CONTACT WITH CONCRETE AND AT

2024
F. PROJECT IDENTIFICATION: PROVIDE 32 SQUARE FOOT SIGN LISTING TITLE OF A615, DEFORMED REINFORCING BARS, GRADE 60 UNLESS OTHERWISE INDICATED, AND ASTM ROOFING; FIRE TREAT WOOD CONCEALED IN INTERIOR WHERE REQUIRED BY
PROJECT, OWNER, ARCHITECT, PROFESSIONAL CONSULTANTS AND CONTRACTOR; A185 WELDED WIRE FABRIC; GALVANIZED. APPLICABLE AUTHORITIES.
EXTERIOR PLYWOOD CONSTRUCTION PAINTED BY PROFESSIONAL SIGN PAINTER.
1. OTHER SIGNS: SUBJECT TO OWNER AND ARCHITECT APPROVAL.
G.FIELD TELEPHONE AND STORAGE: PROVIDE FIELD TELEPHONE AND ON-SITE AND
END OF SECTION
NOT USED
E. CONCRETE: COMPLY WITH ACI 301 AND 318; NOT LESS THAN 3000 PSI AT 28 DAYS,
MAXIMUM 1” AGGREGATE, MAXIMUM 3” SLUMP, 4% TO 5% AIR ENTRAINMENT, UNLESS
OTHERWISE INDICATED.
1. PRESSURE TREATED: WATER-BORNE PRESERVATIVES FOR ABOVE GROUND USE
CONFORMING TO AWPA C2 AND C9.
2. FIRE TREATED: CONFORM TO APWA C20 AND C27, INTERIOR TYPE A AT
OFF-SITE STORAGE AS REQUIRED FOR CONSTRUCTION. 1. PORTLAND CEMENT: ASTM C150 TYPE I OR II STANDARD. INTERIOR APPLICATIONS; PASS ASTM D2898RAIN TEST WHERE AT EXTERIOR
1. PROVIDE CELLULAR TELEPHONES FOR ON-SITE SUPERVISOR AND SUBMIT WALLS AND ROOF; IDENTIFY WITH FRTW.
2. AGGREGATES: ASTM C33 NORMAL WEIGHT
REGULARLY UPDATED SCHEDULE OF ON-SITE SUPERVISOR WITH CELLULAR 3. KILN-DRY TREATED WOOD TO 19% MOISTURE CONTENT; DISCARDS WARPED
TELEPHONE NUMBERS. 3. ADMIXTURES: ASTM C494 AS NEEDED NO CHLORIDES PERMITTED AND DAMAGED PIECES.
H. REMOVAL: REMOVE TEMPORARY CONSTRUCTION FACILITIES PRIOR TO SUBSTANTIAL F. FINISHES: COMPLY WITH ACI FOR STANDARD CONCRETE FINISHED. F. FASTENERS: GALVANIZED AT EXTERIOR LOCATIONS AND PRESSURE TREATED WOOD;
COMPLETION. 1. FLOOR SLABS: PROVIDE HARDENER/SEALER AT FLOORS INDICATED TO BE EXPOSED AND SIZE AND TYPE TO SUIT APPLICATION; PROVIDE WASHERS FOR NUTS AND BOLTS.
1. CLEAN AND REPAIR DAMAGE CAUSED BY CONSTRUCTION FACILITIES. AS REQUIRED FOR THIN FLOOR FINISHES. G.INSTALLATION: COMPLY WITH REFERENCED STANDARDS AND APPLICABLE CODE SHEET NO:
I. SITE WASTE MANAGEMENT: COMPLY WITH APPLICABLE AUTHORITIES FOR SITE WASTE
MANAGEMENT =; MINIMUM 50% OF TOTAL PROJECT WASTE TO BE DIVERTED FROM
LANDFILL. EFFECT OPTIMUM CONTROL OF SOLID WASTES. PREVENT ENVIRONMENTAL
POLLUTION AND DAMAGE.
G.INSTALLATION:
COMPLY WITH MANUFACTURER RECOMMENDATION, REFERENCED STANDARDS, AND
APPLICABLE CODE REQUIREMENTS.
REQUIREMENTS.

END OF SECTION A-931


1. WASTE: CONSTRUCTION WASTE INCLUDE SOLID WASTES SUCH AS BUILDING END OF SECTION
MATERIALS, PACKING, RUBBISH, DEBRIS, AND RUBBLE RESULTING FROM REV. NO:
CONSTRUCTION OPERATIONS.
2. RECYCLING: IMPLEMENT RECYCLING PROGRAM THAT INCLUDES SEPARATE
COLLECTION OF RECYCLABLE WASTE MATERIALS BY BOTH CONTRACTOR AND
SUBCONTRACTORS.
3. REBATES, TAX CREDITS, AND OTHER SAVINGS OBTAINED FOR RECYCLED AND D.O.B. NO:
RE-USED MATERIALS SHALL ACCRUE TO CONTRACTOR.

END OF SECTION
SECTION 06 20 00 - FINISH CARPENTRY GENERAL: SECTION 07 40 00 ROOF REPAIRS GENERAL:

A.PROVIDE WOOD TRIM INCLUDING WOOD DOOR JAMBS, WOOD SHELVING, CLOSET POLES, A.REPAIR EXISTING ROOF SYSTEMS AS REQUIRED FOR NEW CONSTRUCTION WAS ACCESSORIES FOR
COATEDWIRE CLOSET POLES, MOP HOLDERS, AND ACCESSORIES AS REQUIRED FOR COMPLETE COMPLETE WEATHER TIGHT INSTALLATION, WHERE APPLICABLE PER LEASE.
FINISHED INSTALLATION.
B. STANDARDS: CONFORM TO NATIONAL ROOFING CONTRACTORS ASSOCIATION ROOFING AND
B. STANDARDS: CONFORM TO WOODWORK INSTITUTE (WI) “MANUAL OF MILLWORK: STANDARDS OR WATERPROOFING MANUAL 4TH OR 5TH EDITION.
ARCHITECTURAL WOODWORK INSTITUTE (AWI) “QUALITY STANDARDS” AND APPLICABLE CODES.
C. WARRANTY: PROVIDE FOR CORRECTING FAILURE OF ROOF REPAIRS TO RESIST PENETRATION OF WATER
C. OPAQUE PAINTED WOOD TRIM: CUSTOM GRADE, POPLAR OR WHITE BIRCH (MDF NOT ACCEPTABLE).
D. WOOD SHELVING: WI/CUSTOM GRADE, ¾” WOOD BOARD OR HARDWOOD-EDGED PLYWOOD.
1. ADJUSTABLE SUPPORTS: HEAVY DUTY TYPE WITH DINGLE SLOTS 2” ON CENTER, 12”
NOT USED
AND DAMAGE FROM WIND; WARRANTY PERIOD OF TWO YEARS.
1. WHERE EXISTING BUILDING HAS WARRANTY, COMPLY WITH REQUIREMENTS OF EXISTING ROOF
WARRANTY FOR REPAIRS.
JEFFREY
STANDARDS UNLESS OTHERWISE INDICATED; FINISH AS SELECTED BY ARCHITECT FROM D. ROOFING SYSTEM: MATCH EXISTING ROOFING, NO SUBSTITUTIONS PERMITTED; PROVIDE MATERIAL TAYLOR
STANDARD FINISHES. CAPABLE OF MAINTAINING EXISTING WARRANTIES; CONFORM TO REQUIREMENTS OF NRCA ROOFING
MANUAL AND APPLICABLE CODE REQUIREMENTS. ARCHITECT
E. JANITOR CLOSET MOP HOLDERS: SPRING LOADED ANTI-SLIP MOP HOLDER WITH RUBBER CAM, WITH
THREE MOP HOLDERS ON STAINLESS STEEL. 1. SYSTEM: PROVIDE COMPLETE SYSTEM WITH ACCESSORIES AS REQUIRED FOR REPAIR.
1. MANUFACTURERS: BOBRICK WASHROOM EQUIPMENT, INC./MODEL B-223; BRADLEY E. ROOF SYSTEM REPAIRS: COMPLY WITH MANUFACTURER'S RECOMMENDATIONS AND INSTRUCTIONS AND 572 NORTH BROADWAY
CORP./MODEL 9953; AMERICAN SPECIALTIES INC./MODEL 0796A. NRCA RECOMMENDATIONS FOR ROOF TYPE SPECIFIED. WHITE PLAINS, NEW YORK 10603
F. ACCESSORIES: PROVIDE AS INDICATED, AS RECOMMENDED BY WOODWORK INSTITUTE FOR
TEL 914 289 0011
APPLICATIONS INDICATED, AND AS REQUIRED FOR COMPLETE INSTALLATION AS INDICATED. END OF SECTION
G.INSTALLATION: INSTALL WORK CONSISTENT WITH SPECIFIED WI MOM QUALITY GRADE, PLUMB,
LEVEL, TRUE AND STRAIGHT WITH NO DISTORTIONS; SHIM AS REQUIRED, USING CONCEALED SHIMS. SECTION 07 81 00 - SPRAYED-ON FIREPROOFING
1. INSTALL TRIM IN SINGLE, UNJOINTED LENGTHS FOR OPENINGS AND FOR RUNS LESS THAN
10'-0”; FOR LONGER USE ONLY ONE PIECE LESS THAN 10'-0”; PROVIDE SCARF JOINTS
BETWEEN MEMBERS, STAGGER JOINTS IN ADJACENT MEMBERS; MITER CORNERS; NOT LESS A. GENERAL: CEMENTITIOUS OR MINERAL FIBER SPRAY-ON FIREPROOFING AS REQUIRED BY APPLICABLE
THAN TWO FASTENERS EACH. CODES FOR APPLICABLE FIRE RESISTIVE CONSTRUCTION; NO ASBESTOS PERMITTED.

H. PREPARATION FOR FIELD FINISHING: SAND WORK SMOOTH AND SET EXPOSED NAILS AND SCREWS; B. MANUFACTURERS: W.R. GRACE/MONOKOTE OR ALBI MANUFACTURING DIVISION
APPLY WOOD FILLER IN EXPOSED NAIL AND SCREW INDENTATION AND LEAVE READY TO RECEIVE STANCHEM/DURASPRAY, OR APPROVED EQUAL.
SITE-APPLIED FINISHES. C. INSTALLATION: INSTALL IN ACCORDANCE MANUFACTURER RECOMMENDATION AND FIRE TEST RESULTS AS
1. SEAL CONCEALED AND SEMI-CONCEALED SURFACES; BRUSH APPLY ONLY, USING PRIMER REQUIRED TO PROVIDE REQUIRED FIRE RATINGS.
CONSISTENT WITH FINISH COAST SPECIFIED UNDER SECTION 09900 - PAINTS AND COATINGS.
END OF SECTION
END OF SECTION
SECTION 07 84 00 - FIRESTOPPING
SECTION 06 40 00 - ARCHITECTURAL WOODWORK LIC # AR0015561
A. GENERAL: PROVIDE PENETRATION-TYPE FIRESTOPPING FOR TIME-RATED FLOOR, WALL, AND PARTITION
A. GENERAL: PROVIDE WOOD CASEWORK AND COUNTERTOPS, WOOD PANELING AND ACCESSORIES ASSEMBLIES CAPABLE OF PREVENTING PASSAGE OF FLAME, SMOKE AND HOT GLASS.
AS REQUIRED FOR COMPLETE FINISHED INSTALLATION.
B. CODES: CONFORM TO APPLICABLE CODE REQUIREMENTS FOR BOTH F AND T RATINGS.
B. STANDARDS: CONFORM TO WOODWORK INSTITUTE (WI) “MANUAL OF MILLWORK” OR
ARCHITECTURAL WOODWORK INSTITUTE (AWI) “QUALITY STANDARDS”; PREMIUM GRADE UNLESS C. STANDARDS: PASS ASTM E814 THROUGH-PENETRATION FIRE STOPS, ASTM E119 FIRE TESTS AND ASTM
OTHERWISE INDICATED. E84 FLAME SPREAD/SMOKE CONTRIBUTION MAXIMUM 25/25.
1. CERTIFICATION: PROVIDE CERTIFICATION D. MANUFACTURES: 3M/FIRE BARRIER, STI/SPECSEAL OR PENSIL, OR HILTI/FIRESTOP SYSTEMS, OR APPROVED
C. MANUFACTURES: MEMBERS OF WOODWORK INSTITUTE (WI) OR ARCHITECTURAL WOODWORK EQUAL.
INSTITUTE (AWI) WITH MINIMUM FIVE YEARS SUCCESSFUL EXPERIENCE FABRICATING ARCHITECTURAL E. INSTALLATION: INSTALL IN ACCORDANCE MANUFACTURER RECOMMENDATIONS AND FIRE TEST RESULTS
WOODWORK SIMILAR TO THAT REQUIRED FOR PROJECT. AS REQUIRED TO PROVIDE REQUIRED FIRE RATINGS. EXP. 2/28/2025
D. CASEWORK: FRAMELESS TYPE AS INDICATED ON DRAWINGS; CUSTOM SINGLE COMPONENT UNITS
BASED ON WALL SPACE USING FIELD MEASUREMENTS. END OF SECTION REVISION:
1. TRANSPARENT/STAINED FINISHED: PREMIUM GRADE VENEER AS APPROVED BY CLIENT
2. PLASTIC LAMINATE FINISHED: WI/CUSTOM GRADE WITH NEMA LD-3 GENERAL PURPOSE TYPE SECTION 07 90 00 - JOINT SEALERS
HIGH PRESSURE LAMINATE; FORMICA, LAMINART, OR WILSONART
a. HORIZONTAL SURFACE: MINIMUM 0.050”
A. GENERAL: PROVIDE EXTERIOR AND INTERIOR JOINT SEALERS NOT PROVIDE ELSEWHERE TYPE SUITABLE FOR
b. VERTICAL SURFACES: MINIMUM 0.030” APPLICATION INDICATED WITH ACCESSORIES AS REQUIRED FOR COMPLETE INSTALLATION.
c. BACK-UP SHEETS: MINIMUM 0.020” B. VERIFICATION: MANUFACTURER REPRESENTATIVE TO REVIEW PROJECT AND VERIFY IN WRITING JOINT
3. PARTICLEBOARD: PROVIDE MEDITE CORP. (SIERRAPINE) MEDITE II OR RODMAN SEALERS ARE COMPATIBLE WITH SUBSTRATES AND APPLICATIONS INDICATED.
INDUSTRIES/RESINCORE I FORMALDEHYDE-FREE PARTICLEBOARD MADE FROM RECYCLED C. ELASTOMERIC SEALANTS:
WOOD PRODUCTS. ISSUE DATE:
1. EXTERIOR NON-TRAFFIC JOINTS: GE/SILPRUG, DOW/790-795, OR PEDCORA/854, LOW
E. PLASTIC LAMINATE COUNTERTOPS: NEMA LA-3 GENERAL PURPOSE TYPE HIGH PRESSURE PLASTIC MODULUS SILICONE SEALANT, OR APPROVED EQUAL 06.12.23 FOR REVIEW & APPROVALS
LAMINATE BY FORMICA, LAMINART, OR WILSONART, MINIMUM 0.042” POSTFORMING TYPE WITH 07.17.23 FOR BIDS & PERMITS
0.020” BACK-UP SHEETS. 2. TRAFFIC BEARING JOINTS: MAMECO/VULKEM 245 OR PECORS/NR-200 UREXPAN,
MULTI-COMPONENT POLYURETHANE, SELF-LEVELING JOINT SEALER, OR APPROVED EQUAL
F. SOLID POLYMER COUNTERTOPS: COMPARABLE TO WI MOM/PREMIUM GRADE; MANUFACTURE'S
STANDARD POLYMER SYSTEM WITH COLOR THROUGHOUT THICKNESS; PROVIDE MANUFACTURE 3. MILDEW-RESISTANT SANITARY SEALANTS: GE/SANITARY DEALANT, DOW/BATHTUB CAULK, OR
RECOMMENDED JOINT ADHESIVE; EXPOSED SURFACES FINISHED TO MATCH TOP. PECORS/863 #345 WHITE; PROVIDE AT INTERIOR AREAS WHERE SEALANT WILL BE EXPOSED TO
WATER.
1. MANUFACTURES: DUPONT/CORIAN, AVONITE, FORMICA/SURELL, SWAN/SWANSTONE
D. NON-ELASTOMERIC SEALANTS:
2. COLOR: MANUFACTURER'S STANDARD COLOR AS SELECTED BY ARCHITECT
1. GENERAL INTERIOR JOINT SEALER: PECORA/AC-20 OR SONNEBORN/SONOLAC, ACRYLIC OR
G.CASEWORK HARDWARE: CHROME OR BRUSHED ALUMINUM FINISH LATEX EMULSION OR APPROVED EQUAL. ARCH PROJECT NO.: 10835
1. SHELF SUPPORTS: KNAPE & VOGT 255 STANDARDS, 256 SUPPORT; RECESSED PRODUCT SEASON: 2024
E. MISCELLANEOUS MATERIAL” PRIMERS, SEALERS, JOINT CLEANERS, BOND BREAKER TAPE, AND SEALANT
BACKER RODS AS RECOMMENDED BY SEALANT MANUFACTURE FOR APPLICATION INDICATED. SPACE NO.: 185
2. HINGES: EUROPEAN STYLE CONCEALED HINGES JTA
DRAWN BY:
3. SLIDES: FULL EXTENSION SLIDES, NOT LESS THAN 100 LB. CAPACITY F. PREPARATION: CLEAN JOINT SURFACES IMMEDIATELY BEFORE INSTALLATION OF JOINT SEALER, AND PRIME
SCALE: AS NOTED
OR SEAL JOINT SURFACES AS RECOMMENDED BY MANUFACTURER.
4. CABINET PULLS: 3” WIRE PULLS
G.INSTALLATION: COMPLY WITH MANUFACTURER'S PRINTED INSTALLATION INSTRUCTIONS AND ASTM
5. LOCKS: REQUIRED AT ALL DOORS AND DRAWERS C1193. SHEET TITLE:
H. WOOD PANELING: PREMIUM GRADE PLYWOOD PANELING WITH WHITE BIRCH VENEER FOR 1. EMPLOY INSTALLATION TECHNIQUES WHICH WILL ENSURE JOINT SEALERS ARE DEPOSITED IN
OPAQUE PAINT FINISH; TONGUE AND GROOVE EDGES. UNIFORM, CONTINUOUS RIBBONS WITHOUT GAPS OR AIR POCKETS, WHITE COMPLETE SPECIFICATIONS
I. TRANSPARENT/STAINED FINISHED WOODWORK: WI/PREMIUM GRADE VENEERS AS INDICATED ON “WETTING” OF BOND SURFACES.
DRAWINGS; VENEERING AS DIRECTED BY ARCHITECT WHERE NOT OTHERWISE INDICATED.
1. SAND WORK SMOOTH; SEAL, STAIN AND VARNISH CONCEALED AND SEMI-CONCEALED END OF SECTION
SURFACES OF TRANSPARENT FINISHED WOODWORK; BRUSH APPLY
2. FINISH: WI/PREMIUM GRADE FINISH AS DIRECTED BY ARCHITECT SECTION 08 11 00 - STEEL DOORS AND FRAMES

THE MALL AT WELLINGTON GREEN


J. INSTALLATION: COMPLY WITH INSTITUTE STANDARDS AND MANUFACTURE RECOMMENDATIONS.

STORE NO. US 326 - RED MOD

BLVD.WELLINGTON, FL. 33414


A. GENERAL PROVIDE STEEL DOOR AND FRAMES, INCLUDING HOLLOW METAL (PRESSED STEEL) FRAMES, AND
ACCESSORIES AS REQUIRED FOR COMPLETE INSTALLATION.

10300 W. FOREST HILL


END OF SECTION
1. COORDINATE WITH SECTION 08700 HARDWARE
SECTION 07 26 00 - SLAB-ON-GRADE VAPOR RETARDER B. STANDARDS: COMPLY WITH STEEL DOOR INSTITUTE (SDI): SDI-100 (ANSI/SDI A250.8) -RECOMMENDED
SPECIFICATIONS - STANDARD STEEL DOORS AND FRAMES OR NAAMM HOLLOW METAL MANUFACTURERS

2024
ASSOCIATION “HOLLOW METAL MANUAL”
A. GENERAL: PROVIDE SLAB-ON-GRADE VAPOR RETARDER
C. MANUFACTURERS: CECO, CURRIES, AMWELD, OR PIONEER, OR APPROVED EQUAL.
B. MANUFACTURER: FORITFIBER CORP./MOISTOP ULTRA; STEGO INDUSTRIES, INC./ STEGO WRAP (15
D. HOLLOW METAL DOORS: FLUSH HOLLOW METAL DOORS FULL FLUSH TYPE WITH FILLED EDGE; CLOSE
MIL); RAVEN INDUSTRIES, INC./VAPOR BLOCK #VB 15 (15 MIN BLUE) OR APPROVED EQUAL.
TOP AT EXTERIOR DOORS.
C. VAPOR RETARDER: ASTM E1745, CLASS A WATER RESISTANT RETARDER CONSISTING OF 15 MIL
1. CORE: PROVIDE STEEL STIFFENED CORE; INSULATED AT EXTERIOR DOORS,
POLYOLEFIN FILM
2. GAGE: PROVIDE MINIMUM 18 GAGE AT INTERIOR DOORS, MINIMUM 16 GAGE AT EXTERIOR
1. PERMEANCE: MAXIMUM 0.025 PERMS, ASTM F1249 AND E154 TESTS.
DOORS.
D. JOINT SEALER: PRESSURE SENSITIVE TAPE AS RECOMMENDED BY VAPOR RETARDER MANUFACTURER
E. PRESSED STEEL (HOLLOW METAL) FRAMES: MINIMUM 16 GAGE WELDED (PRE-ASSEMBLED) FRAMES
AND PROVING COMPARABLE PREMEANCE TO VAPOR RETARDER.
EXTERIOR, KNOCK-DOWN (FILED-ASSEMBLED) FRAMES INTERIOR.
E. SAN BED: CLEAN DRY NATURAL SAND; FREE FROM SILT, CLAY, LOAM, FRIABLE, OR SOLUBLE MATERIALS,
F. FIRED RATED UNITS: CONFORM TO NFPA 80; PROVIDE UL OR WARNOCK HERSEY LABELED DOORS AND
AND ORGANIC MATTER.
FRAMES AS REQUIRED. SHEET NO:
F. INSTALLATION: COMPLY WITH MANUFACTURE RECOMMENDATIONS; TAPE JOINTS AND TEARS IN

A-932
G.ACCESSORIES: PROVIDE DOOR SILENCERS, ANCHORS, AND ACCESSORIES. PROVIDE SQUARE GLAZING
VAPOR RETARDER.
STOPS AS APPROVED BY ARCHITECT FOR GLAZING IN METAL DOORS AND FRAMES.
H. FINISH: PRIME PAINT INTERIOR UNITS, GALVANIZE AND PRIME PAINT EXTERIOR UNITS; MINIMUM A60
END OF SECTION GALVANIZING; CLEAN, DEGREASE AND FACTORY PRIME PAINT.
I. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS, SDI OR NAAMM STANDARDS, AND
APPLICABLE REQUIREMENTS FOR FIRE RATINGS. REV. NO:

END OF SECTION

D.O.B. NO:
JEFFREY
TAYLOR
ARCHITECT

572 NORTH BROADWAY


WHITE PLAINS, NEW YORK 10603

TEL 914 289 0011

EXISTING LIGHTBOX TO BE EXISTING LIGHTBOX TO BE EXISTING LIGHTBOX TO BE


REMOVED AS DASH SHOWN REMOVED AS DASH SHOWN REMOVED AS DASH SHOWN

LIGHT BOX LIGHT BOX LIGHT BOX

EXISTING WALL AND WARDROBE TO BE EXISTING WARDROBE TO BE


LIC # AR0015561
EXISTING LIGHTBOX TO BE
REMOVED AS DASH SHOWN REMOVED AS DASH SHOWN REMOVED AS DASH SHOWN

LIGH
T BO
X

EXISTING WALL AND WARDROBE TO BE


REMOVED AS DASH SHOWN EXISTING WALL AND
WARDROBE TO BE
REMOVED AS DASH
SHOWN
NEW WALL TO BE BUILT
AS SHOWN

EXISTING DOOR AND MIRROR EXP. 2/28/2025


TO BE REMOVED AS DASH
SHOWN

REVISION:

NEW WALL TO BE BUILT


AS SHOWN
EXISTING MIRROR TO BE
REMOVED AS DASH SHOWN

EXISTING WALL AND


WARDROBE TO BE REMOVED AS
DASH SHOWN

EXISTING DECO LIGHT TO BE


REMOVED AS DASH SHOWN

EGRESS CORRIDOR
NEW WALL TO BE BUILT
ISSUE DATE:
AS SHOWN
06.12.23 FOR REVIEW & APPROVALS
07.17.23 FOR BIDS & PERMITS
EXISTING MIRROR TO BE EXISTING MIRROR TO
EXISTING DECO LIGHT TO BE REMOVED AS DASH BE REMOVED AS DASH

FOR REFERENCE ONLY


REMOVED AS DASH SHOWN SHOWN SHOWN

EXISTING PODIUM TO BE
REMOVED AS DASH SHOWN EXISTING WARDROBE TO BE
REMOVED AS DASH SHOWN
EXISTING MIRROR EXISTING 1 WALL WASHER TO BE
TO BE REMOVED AS REMOVED AS DASH SHOWN

NEW WALL AND


EXISTING 2 SPOT
LIGHTS TO BE
EXISTING MIRROR TO BE
EXISTING CASHPOINT TO
DASH SHOWN
EXISTING WALL TO BE REMOVED AS ARCH PROJECT NO.: 10835
DOOR TO BE BUILT REMOVED AS DASH SHOWN DASH SHOWN TO OPEN UP THE
REMOVED AS DASH BE REMOVED AS DASH
2024

FILE

FILE
SAFE
AS SHOWN SHOWN SHOWN FITTING ROOM ENTRANCE PRODUCT SEASON:
EXISTING 1 WALL

30"x60"
WASHER TO BE
MILLWORK
LAN
RACK
SPACE NO.: 185
EXISTING WALL FIXTURES TO BE REMOVED AS

SECURITY
DECO TABLE

MONITOR
DRAWN BY: JTA

30"x36"
REMOVED AS DASH SHOWN DASH SHOWN NEW WALL TO SERVICE
EXISTING WARDROBE TO BE BUILT AS SINK
BE REMOVED AS DASH
SHOWN EXISTING DECO
SHOWN
SCALE: AS NOTED
LIGHT TO BE NEW LOW WALL
REMOVED AS 95mm TO BE BUILT
EXISTING WARDROBE TO BE EXISTING 2 WALL WASHERS TO EXISTING LIGHTBOX TO BE AS SHOWN EXISTING WATER EXISTING VENDING MACHINE
REMOVED AS DASH SHOWN BE REMOVED AS DASH SHOWN REMOVED AS DASH SHOWN DASH SHOWN FOUNTAIN TO BE TO BE REMOVED AS DASH
EXISTING WALL AND DOOR UPDATED SHOWN

EXISTING INTERIOR PACKAGE TO BE


TO BE REMOVED AS DASH SHEET TITLE:
SHOWN
REMOVED AS DASH SHOWN T-WAVE T-WAVE

LOCKERS
CONSTRUCTION PLAN
VENDING
EXISTING WALL

LOCKERS
FIXTURE TO BE SINK

SUSP.
REMOVED AS SHOWN X-MER
COUCH
EXISTING HANGER TO BE
REMOVED, SAVE FOR
RELOCATION COAT CONCRETE PAD
TRANS TRANS
HANGER FORMER FORMER

VENDING 1125 1125


KVA MDP KVA
REFRIG.

THE MALL AT WELLINGTON GREEN


STORE NO. US 326 - RED MOD

BLVD.WELLINGTON, FL. 33414


10300 W. FOREST HILL
2024
SHEET NO:

IPS-1.1
REV. NO:

D.O.B. NO:
JEFFREY
TAYLOR
ARCHITECT

572 NORTH BROADWAY


WHITE PLAINS, NEW YORK 10603

TEL 914 289 0011

WOMENS KIDS
LIGHTBOX LIGHTBOX

LIC # AR0015561

EXP. 2/28/2025

REVISION:

ISSUE DATE:

EGRESS CORRIDOR
06.12.23 FOR REVIEW & APPROVALS
07.17.23 FOR BIDS & PERMITS

FOR REFERENCE ONLY


ARCH PROJECT NO.: 10835
PRODUCT SEASON: 2024

FILE

FILE
SAFE
SPACE NO.: 185

30"x60"
LAN
MILLWORK
RACK
DRAWN BY: JTA

SECURITY
DECO TABLE

MONITOR

30"x36"
SERVICE
SINK
SCALE: AS NOTED
LOW WALL
95mm

EXISTING HANGER SYSTEM TO BE


RELOCATED AS SHOWN
SHEET TITLE:
T-WAVE T-WAVE

LOCKERS
FIXTURE LAYOUT

LOCKERS
SINK

SUSP.
X-MER
COUCH

CONCRETE PAD
COAT TRANS TRANS
HANGER FORMER FORMER

VENDING 1125 1125


KVA MDP KVA
REFRIG.

PROCESSING TABLE

THE MALL AT WELLINGTON GREEN


STORE NO. US 326 - RED MOD

BLVD.WELLINGTON, FL. 33414


10300 W. FOREST HILL
CURTAIN RAILING ORDERING
L L
L L
L L

2024
L L
L L
L L
L L
L L

SHEET NO:

IPS-1.2
REV. NO:

D.O.B. NO:
JEFFREY
TAYLOR
ARCHITECT

572 NORTH BROADWAY


WHITE PLAINS, NEW YORK 10603

TEL 914 289 0011

LIC # AR0015561

EXP. 2/28/2025

REVISION:

EGRESS CORRIDOR
ISSUE DATE:
06.12.23 FOR REVIEW & APPROVALS
07.17.23 FOR BIDS & PERMITS

FOR REFERENCE ONLY


ARCH PROJECT NO.: 10835
PRODUCT SEASON: 2024

FILE

FILE
SAFE
SPACE NO.: 185

30"x60"
LAN
RACK
MILLWORK

DRAWN BY: JTA

SECURITY
DECO TABLE

MONITOR

30"x36"
SERVICE
SINK
SCALE: AS NOTED

SHEET TITLE:
T-WAVE T-WAVE

LOCKERS
CEILING GENERAL NOTES LIGHTING PLAN

LOCKERS
SINK

SUSP.
X-MER

TURN OFF ALL COVE LIGHTING COUCH

CONCRETE PAD
COAT TRANS TRANS
HANGER FORMER FORMER

VENDING 1125 1125


KVA MDP KVA
REFRIG.

THE MALL AT WELLINGTON GREEN


STORE NO. US 326 - RED MOD

BLVD.WELLINGTON, FL. 33414


10300 W. FOREST HILL
CURTAIN RAILING ORDERING
L L
L L
L L

2024
L L
L L
L L
L L
L L

SHEET NO:

IPS-1.3
REV. NO:

D.O.B. NO:
JEFFREY
TAYLOR
ARCHITECT

572 NORTH BROADWAY


WHITE PLAINS, NEW YORK 10603

TEL 914 289 0011

LIC # AR0015561

PAINTED STORE GUIDE

KIDS DEPARTMENT PAINTED NAVIGATION


CENTERED ABOVE THE PORTAL
MENS DEPARTMENT NAVIGATION
FITTING ROOM PAINTED WOMENS DEPARTMENT FITTING ROOM PAINTED WOMENS DEPARTMENT CENTERED ABOVE THE PORTAL
NAVIGATION NAVIGATION CENTERED ABOVE NAVIGATION NAVIGATION CENTERED ABOVE EXP. 2/28/2025
THE PORTAL THE PORTAL

REVISION:

MENS DEPARTMENT NAVIGATION MENS DEPARTMENT NAVIGATION


CENTERED ABOVE THE PORTAL CENTERED ABOVE THE PORTAL

FITTING ROOM +
CASHPOINT PAINTED

EGRESS CORRIDOR
KIDS DEPARTMENT PAINTED NAVIGATION
NAVIGATION CENTERED ABOVE
PAINTED STORE GUIDE THE PORTAL ISSUE DATE:
06.12.23 FOR REVIEW & APPROVALS
07.17.23 FOR BIDS & PERMITS

FOR REFERENCE ONLY


WOMENS/DIVIDED DEPARTMENT
NAVIGATION CENTERED ABOVE THE
CLICK & COLLECT PAINTED PORTAL
NAVIGATION

FITTING ROOM PAINTED


NAVIGATION

ARCH PROJECT NO.: 10835

FILE

FILE
SAFE
PRODUCT SEASON: 2024

30"x60"
LAN
MILLWORK
RACK
SPACE NO.: 185

SECURITY
DECO TABLE

MONITOR

30"x36"
SERVICE
SINK DRAWN BY: JTA
SCALE: AS NOTED

PAINT ONLY APPLY TO THE WALL SHEET TITLE:


WALL FINISH GENERAL NOTES ABOVE THE CABINS T-WAVE T-WAVE

LOCKERS
WALL FINISH PLAN

LOCKERS
SINK

1. PAINT ALL EXISTING NON-WHITE COLOR COUCH


SUSP.
X-MER

WARDROBES IN WOMEN'S & KID'S


DEPARTMENTS TO STANDARD STORE WHITE COAT
HANGER
TRANS
FORMER
CONCRETE PAD
TRANS
FORMER

COLOR REFRIG.
VENDING 1125
KVA
MDP
1125
KVA

2. REMAIN EXISTING WOOD COLOR


WARDROBES IN MEN'S DEPARTMENT

THE MALL AT WELLINGTON GREEN


STORE NO. US 326 - RED MOD

BLVD.WELLINGTON, FL. 33414


10300 W. FOREST HILL
L L
L L
L L
L L
L L

2024
L L
L L
L L

SHEET NO:

IPS-1.4
REV. NO:

D.O.B. NO:
JEFFREY
TAYLOR
ARCHITECT

572 NORTH BROADWAY


WHITE PLAINS, NEW YORK 10603

TEL 914 289 0011

PATCH THE FLOOR AS NEEDED LIC # AR0015561

RELOCATE THE EXISTING SKIRTING


FROM THE DEMO WALLS FOR THE NEW
PARTITIONS
PATCH THE FLOOR AS NEEDED
PATCH THE FLOOR AS NEEDED

RELOCATE THE EXISTING SKIRTING


FROM THE DEMO WALLS FOR THE NEW
PARTITIONS
EXISTING FLOORING TO REMAIN, CLEAN &
POLISH AS NEEDED.

EXP. 2/28/2025

REVISION:
RELOCATE THE EXISTING SKIRTING
FROM THE DEMO WALLS FOR THE NEW
PARTITIONS

POLISH AS NEEDED.
EXISTING FLOORING TO REMAIN, CLEAN &
PATCH THE FLOOR AS NEEDED

RELOCATE THE EXISTING SKIRTING


FROM THE DEMO WALLS FOR THE NEW
PARTITIONS

EGRESS CORRIDOR
RELOCATE THE EXISTING SKIRTING
FROM THE DEMO WALLS FOR THE NEW ISSUE DATE:
PARTITIONS
06.12.23 FOR REVIEW & APPROVALS
07.17.23 FOR BIDS & PERMITS

FOR REFERENCE ONLY


EXISTING FLOORING TO REMAIN, CLEAN &
POLISH AS NEEDED.

RELOCATE THE EXISTING SKIRTING ARCH PROJECT NO.: 10835


FROM THE DEMO WALLS FOR THE NEW
PARTITIONS PATCH THE FLOOR AS NEEDED PRODUCT SEASON: 2024

FILE

FILE
SAFE
SPACE NO.: 185

30"x60"
LAN
RACK
MILLWORK

DRAWN BY: JTA

SECURITY
DECO TABLE

MONITOR

30"x36"
SERVICE
SINK
SCALE: AS NOTED

NEW TILE TO MATCH THE


FITTING ROOM FLOORING AS
DASH SHOWN SHEET TITLE:
T-WAVE T-WAVE

LOCKERS
FLOORING GENERAL NOTES FLOOR FINISH PLAN

LOCKERS
SINK

SUSP.
X-MER

REPLACE FLOORING IN BOH COUCH

CONCRETE PAD
COAT TRANS TRANS
HANGER FORMER FORMER

VENDING 1125 1125


KVA KVA
REFRIG. MDP

THE MALL AT WELLINGTON GREEN


STORE NO. US 326 - RED MOD

BLVD.WELLINGTON, FL. 33414


10300 W. FOREST HILL
2024
SHEET NO:

IPS-1.5
REV. NO:

D.O.B. NO:
JEFFREY
TAYLOR
ARCHITECT

572 NORTH BROADWAY


WHITE PLAINS, NEW YORK 10603

TEL 914 289 0011

EXISTING LOGO TO BE REMOVED AND EXISTING PODIUM TO BE EXISTING LEASING LINE


REPLACED WITH NEW HM SUSPENDED REMOVED AND REPLACED WITH
ILLUMINATED LOGO OPEN WINDOW, TYP.

LIC # AR0015561

PAINT WINDOW FRAMES HM METAL COLOR PAINT WINDOW FRAMES HM METAL COLOR

EXISTING SKIRTING TO REMAIN, TYP.

EXISTING WALL TO BE EXISTING WALL TO BE EXP. 2/28/2025


REMOVED AND REPLACED WITH REMOVED AND REPLACED WITH
OPEN WINDOW, TYP. OPEN WINDOW, TYP.
REVISION:

PAINT WINDOW FRAMES HM METAL COLOR PAINT WINDOW FRAMES HM METAL COLOR

EXISTING SKIRTING TO REMAIN, TYP.

ISSUE DATE:
EXISTING LOGO TO BE REMOVED AND EXISTING LIGHTBOX TO BE REMOVED EXISTING WALL AND LIGHTBOX TO BE 06.12.23 FOR REVIEW & APPROVALS
REPLACED WITH NEW HM SUSPENDED AND REPLACED WITH NEW REMOVED, ADD PLANTS AND
ILLUMINATED LOGO FREESTANDING LIGHTBOX
07.17.23 FOR BIDS & PERMITS
CURTAIN, TYP.

FOR REFERENCE ONLY


PAINT WINDOW FRAMES
PAINT WINDOW FRAMES HM METAL COLOR HM METAL COLOR PAINT WINDOW FRAMES
HM METAL COLOR
ARCH PROJECT NO.: 10835
EXISTING SKIRTING TO REMAIN, TYP. EXISTING SKIRTING TO REMAIN, TYP.
PRODUCT SEASON: 2024
SPACE NO.: 185
DRAWN BY: JTA
SCALE: AS NOTED
EXISTING WALL AND LIGHTBOX TO BE EXISTING LEASING LINE
REMOVED, ADD PLANTS AND
CURTAIN, TYP. PAINT WINDOW FRAMES BLACK PAINT WINDOW FRAMES HM METAL COLOR SHEET TITLE:
STOREFRONT
ELEVATIONS
D
EXISTING LOGO TO REMAIN, MAKE SURE
IT'S FUNCTIONAL
PAINT WINDOW FRAMES HM METAL COLOR
ENTRY TO MALL EGRESS
CORRIDOR BEYOND (NIC)

THE MALL AT WELLINGTON GREEN


EXISTING SKIRTING TO REMAIN, TYP. EXISTING SKIRTING TO REMAIN, TYP.

STORE NO. US 326 - RED MOD

BLVD.WELLINGTON, FL. 33414


10300 W. FOREST HILL
2024
SHEET NO:

IPS-1.6
REV. NO:

D.O.B. NO:

You might also like