0% found this document useful (0 votes)
42 views4 pages

Control Ats-R1

This document appears to be a diagram of an electrical control system. It shows various components connected by lines including generators, switches, and distribution panels. Labels include designations for phases, terminals, and voltage inputs. Arrows indicate connections between components forming the control logic and power flow within the system.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
42 views4 pages

Control Ats-R1

This document appears to be a diagram of an electrical control system. It shows various components connected by lines including generators, switches, and distribution panels. Labels include designations for phases, terminals, and voltage inputs. Arrows indicate connections between components forming the control logic and power flow within the system.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

"A"

L1 L2 L3 N
MANUAL (BY TOGLE)

COS ATS XXX A KEY SWITCH

AUTO (SS MANUAL BY PUSH BUTTON - AUTO BY NORMAL SOURCH)


PRIORITY (PLN) GENSET
I II

FA3 FB3
1P, 2A H3 H3 1P, 2A
1T 1 2 2T 2T X1 X2 N1 N2 X2 X1 4T 4T 2 1 3T
G G
FA2 FB2
1P, 2A H2 H2 1P, 2A
1S 1 2 2S 2S X1 X2 N1 N2 X2 X1 4S 4S 2 1 3S
Y Y
FA1 FB1
1P, 2A H1 H1 1P, 2A
1R 1 2 2R 2R X1 X2 N1 N2 X2 X1 4R 4R 2 1 3R
R R

1A 1B
102 104

N1 N2
103 105

101 106 201 202 203 204 205 206 301 302 303 304 305 306

XJ3-D
FC1
1P, 2A 1B
1R 1 2 2R
L1 Ta
FC2
VOLT INPUT

1P, 2A R
1S 1 2 2S Tc
L2
FC3
1P, 2A
1T 1 2 2T Tb
L3

RG 13

14
XA 1 2 3 4 XB 4 3 2 1

L1 L2 L3 N N L3 L2 L1

N2
INCOMING INCOMING
FROM PLN FROM GENSET
"A"

L1 L2 L3 N
FC1
1P, 2A H7
5R 1 2 6R 6R X1 X2 N3
R
FC2
1P, 2A H8
5S 1 2 6S 6S X1 X2 N3
Y
FC3
1P, 2A H9
5T 1 2 6T 6T X1 X2 N3
G

P1 PM
X1
P1 N3

CONTROL
N

POWER
S1 CTR1 CTR2
CT1 S1
1C 01
XXX/5A G L1
S2 L
L
P2 S2

CURRENT INPUT
P1 6R
S1 CTS1 CTS2 V1
CT2 S1
2C 02
XXX/5A G L2

VOLT INPUT
S2 6S
S2 V2
P2
P1
S1 CTT1 CTT2 6T
S1 V3
CT3 3C 03
XXX/5A G L3
S2 N
P2 S2 VN

G
4C 04

PE

BC XXX
FE1 FE2
1P, 2A 1P, 2A
1R 1 2 1C 2C 1 2 3C ( 24VDC )
L1 + (+)

24vdc
220V

VOut
VIn
_
- ( 0V ) TO CONTROL SUPPLY
N3
N (-)

3C -

X1 1 2

L1 L2 L3 N
XC 1 2 3 4

OUTGOING + _ + _

ACCU ACCU
12V 12V
24VDC 3C
(+)

1 3
XJ3-D
SS1 M 0
A Tc

2 MANUAL 4 AUTO Ta Tb

4C

3 3 3
PB1 PB2 PB3
PLN ON OFF GEN ON
4 4 4

4/S1/4

4/S1/4
5C 6C 7C 8C 9C

R1 13 R2 13 R3 13 RM 13 R4 13

14 14 14 14 14

- - - - -

0V
(-)
PLN ON OFF GENSET ON
10C
16C

3
1 5 1 5 1 5 1 5
R1 R2 R4 R3
9 9 9 9 4 AUTO

4/S1/4

4/S1/4

4/S1/4

4/S1/4
17C

10C 11C 12C

1 5 1 5 1 5 1 5
RG R5 RG R4
9 9 15C 9 9
13C

18C

14C 19C 20C

202 203 204 205 201 206 101 302

COS-ATS
106 303 304 305

21C 22C 23C

5C
X2
H4 X2
H5 X2
H6 R5 13

X1 X1 X1 14
PLN ON OFF GEN ON
GREEN RED GREEN

N N N N

You might also like