0% found this document useful (0 votes)
416 views34 pages

OES 2 en

This document outlines standards and specifications for underground cable installations in Oman, including 33kV, 11kV, and low voltage cables. It provides specifications for cable components and installation methods. The specifications cover cable construction requirements, installation procedures for cable laying and jointing, backfilling, identification, protection and testing. Drawings are included that illustrate trench details, joint/marker details, road crossings, and cable layouts for different voltages and situations.

Uploaded by

111
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
416 views34 pages

OES 2 en

This document outlines standards and specifications for underground cable installations in Oman, including 33kV, 11kV, and low voltage cables. It provides specifications for cable components and installation methods. The specifications cover cable construction requirements, installation procedures for cable laying and jointing, backfilling, identification, protection and testing. Drawings are included that illustrate trench details, joint/marker details, road crossings, and cable layouts for different voltages and situations.

Uploaded by

111
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 34

SULTANATE OF OMAN

MINISTRY OF ELECTRICITY & WATER

STANDARD-OES 2

3 3 K V & PILOT, 11KV & L.T.


UNDERGROUND CABLE
INSTALLATIONS

Second Edition: January 1995


置一
了 :1

OF
SULTANATE

OMAN
MINISTRY

OF
ELECTRICITY

&
WATER
二 :二 `飞

STANDARD : OES -2

3 3 K V & PILOT, llKV & L.T. U N D E R G R O U N D C A B L E I N S T A L L A T I O N S


二一
二日

TABLE OF CONTENTS
己二 已
二;

S.No. Description Page


二 已二 二

J.0 Cables 1
二日

2.0 Jomts and Termmauons


9

3.0 Installat1on
3.1 General
3.2 Excavauon of Cable Trenches and Jomt Pits
3.3 Road Crossmg Ducts 2
3.4 Cable Crossmg or Laid Paralle to the Installation Burned Underground 3
3.5 Cable Laymg 5
3.6 Backfilling 6
3.7 Jomllng and Tenmnat10n
3.8 Cable Records
3.9 Earthing 7
3.10 Cable Identification
3.11 Cable Protect:Ion
3.12 Bonding
3.13 Site Tests 8
3.14 Inspec!Ion

SPECIFICATION: U G l -3 3 K V C A B L E S

1.0 General 10
2.0 Conductor
3.0 Conductor Shield
4.0 Insulation
5.0 Insulatwn Shield
6.0 Assembly 11
7.0 Sheath
8.0 Bedding
r,
}

9.0 Armour
吕 B
_

10.0 Overall Serving


11.0 Drum Length
~L
「五 了 么 l .

马』
9
S.No. Description Page

SPECIFICATION: U G 2 - llKV C A B L E S

J.0 General 12
2.0 Conductor
3.0 Conductor Shield
4.0 Insulalion 13
5.0 Insulalion Shield
6.0 Assembly
7.0 Sheath
8.0 Bedding
9.0 A 订 nour
10.0 Overall Servmg
I1.0 Drum Length

SPECIFICATION: U G 3 -600/1000 V O L T S C A B L E S

1.0 General 14
2.0 Conductor
3.0 Shape of Core
4.0 Dress m g
5.0 Insulallon
6.0 Sheath 15
7.0 Armouring
8.0 Servmg
9.0 Drum Length

SPECIFICATION: U G 4 -600 V O L T S 19 C O R E P I L O T C A B L E

1.0 General 16
2.0 Conductors
3.0 Insulat.Jon
4.0 Sheath
5.0 Armounng
6.0 Servmg
7.0 Make up of Pilot Cables
8.0 Drum Length 17

A P P E N D I X -Tests on X L P E Cables 18
DRAWINGS

Drawing Number Title

MEW/E/UG/0101 Details of L. V. cable trench

MEW/E/UG/0102 (Rev. "A") Details of 11 K V cable trench

MEW/E/UG/0103 (Rev. "A") Secllon of 33KV and Pilot cable trench

MEW/E/UG/0104 (Rev. "A") Details of jomt/route markers for power cables

MEW/E/UG/0105 Details of cable markers for side walks

MEW/E/UG/0106 (Rev. "A") Detalils of road crossmg duct for 33KV cable and pilot cable

MEW/E/UG/0107 (Rev. "A") Details of road crossmg ducts for I! K V cable

MEW/E/UG/0108 (Rev. "A") Details of road cross m g ducts for L. V. cable

MEW/E/UG/0109 (Revised) Details of cable covenng tiles

MEW/E/UG/0110 Format for underground power cable record

MEW/E/UG/0112 Cable trench details for different voltages cables I扣d parallel

MEW/E/UG/0113 Details of cables laid parallel to water pipeline

MEW/E/UG/0114 Details of cable crossmg by water pipeline

MEW/E/UG/0115 Details of cable crossmg by telephone cables

You might also like