0% found this document useful (0 votes)
66 views8 pages

Print Reports

Uploaded by

Bibin Kumar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
66 views8 pages

Print Reports

Uploaded by

Bibin Kumar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

8/22/23, 2:46 PM AutoDCR - CheckList

Check List Report


Nedumangad
Version Number: 1.0.42
Version Date: 19/07/2023
Report Generated On: 22-08-2023 

[-] Collapse All

[-] Proposal Information (Table 1)

General Details General Details-2


Name of Local Occupancy
Nedumangad Residential + Mercantile/Commercial
Body Use
Type of Local Occupancy Single Family Dwelling + ResiComm
Municipality Area
Body SubUse Building
File No. TEMP/1035/1056/2023/SC Occupancy
Group A1 + Group F
Application Use Group
General Proposal
Type Development
NA
Permit Type Building Permission Plan

Nature of Land Use


ADDITION OR EXTENSION NA
Development Zone

Special Project NA Highest


Width of
Old Survey No:330/38; Re-Survey 13.80
Abutting
Number:330/38; Revenue Road(mt.)
Village:NEDUMANGADU;
District:TRIVANDRUM;   North PLOT NO-
Site Address
Taluk:NEDUMANGADU; Pin South ROAD WIDTH- 13.80
Code:695028; Nearest Door East PLOT NO-
No.:36/462; Ward:CHIRAYKKANI;
Zone: West PLOT NO-
One day The applicant/owner shall be responsible
Self Certification Permit for the abutting plot details provided in
Permit/Regular
Note Application form as above and abutting
Licensee Details details provided in Site plan for
Type Architect approval.
Name BIBIN K Structure Eng. Details
License Type Structural Engineer
E-11531/19/SB-4770/KLM
No. Name BIBIN.K
EmailID bibin.perila@gmail.com License
E-11531/19/SB-4770/KLM
Mobile No 7356928235 No.
Remark LTP Remark LTP

   
[-]Owner details

Name G.NARAYANAN NAIR


Email ID bibin.perila@gmail.com
Mobile No 8848515576
Address chaithanya venkodu p.o Vattappara pin-695028

   
[-]Licensee details

Name BIBIN K

https://ibpms.kerala.gov.in/AutoDCR.Common2/CommonPages/printReport.aspx?iProposalId=143632&iVal=1 1/8
8/22/23, 2:46 PM AutoDCR - CheckList

Validity 23-09-2023
EMAIL ID bibin.perila@gmail.com
Mobile
7356928235
Number

 
[-] Plot Details (Table 2)
[-] Area From Document (Table 2a)
No. Form Area(Sq.mt.)
1 DEED Document 1417.00
2 Area as per Drawing 486.87
Minimum area of Plot Considered (Sq.mt.) : 486.87
[-] Table 2b
Proposal Detail
Unit
Development Detail
Use Residential + Mercantile/Commercial
Sub Use Single Family Dwelling + ResiComm
Building
Structure Lowrise
Building Type
Gross Plot Area (Sq.mt.) 486.87

[-] Table 2c
COVERED CHECK
Required plot area for weighted coverage 169.89
Actual plot area for weighted coverage 461.85
FSI CHECK
Perm. FSI Area ( 3.00 ) 1460.61
Residential FSI 20.59
Residential Existing FSI(Sq.mt.) 110.43
Mercantile/Commercial FSI 24.10
Total Building FSI Area (Sq.mt.) 151.09
Total FSI Area (Sq.mt.) 151.09
FSI 0.31
BUA CHECK
Proposed BuiltUp Area 40.66
Existing BuiltUp Area 113.33
Total BuiltUp Area 153.99

[-] Weighted FSI Checking


Perm. FSI Perm. FSI
(Without (With
Proposed Achieved
Use SubUse additional Additional Status
FSI FSI
Fee) Fee)
FSI Area FSI Area
SINGLE
RESIDENTIAL FAMILY 131.02 3.0 393.06 0.00 0.00 -
DWELLING
RESICOMM
MERCANTILE/COMMERCIAL 20.08 3.0 60.24 0.00 0.00 -
BUILDING
Total: - 151.10 453.30 0.00 -
Weighted FSI - - 3.00 - NA 0.31 OK

[-] Weighted Covered Checking


Building Use SubUse Floor no. Details of floor Required Actual Status
corresponding corresponding Plot area plot
to max. to max. (sq.mt.)

https://ibpms.kerala.gov.in/AutoDCR.Common2/CommonPages/printReport.aspx?iProposalId=143632&iVal=1 2/8
8/22/23, 2:46 PM AutoDCR - CheckList
required plot required plot area
area area (sq.mt)
BUA Coverage
SINGLE
RESIDENTIAL FAMILY 110.43 65.00 169.89 - -
DWELLING Ground Floor
RESICOMM
S (F) MERCANTILE/COMMERCIAL 20.08 65.00 30.89 - -
BUILDING
SINGLE
RESIDENTIAL FAMILY First Floor 20.59 65.00 31.68 - -
DWELLING
Total Number of Same Buildings 1
Maximum Required Plot area for building S (F) 169.89
Total 169.89 461.85 OK

[-] Check List


Name Description Unit Reqd Perm Proposed Status
[-] Plot Details
Plot Area Sq.Mt. NA NA 461.85 OK
Main Road Width Mt. 1.20 - 13.80 OK
Plot Frontage Mt. - - 22.73 OK
Covered Area Sq.Mt. - NA 133.40 OK
PLOT
FSI Area Sq.Mt. - 1460.61 151.09 OK
Additional FSI Area Sq.Mt. - - - OK
FOC FSI Area Sq.Mt. - - - OK
FSI Sq.Mt. - 3.00 0.31 OK
[-] Resv Road
13.80 M WIDE MAINROAD (Notified
Resv Road Mt. NA 1.10 OK
Road) - ROAD WIDENING AREA - Width
[-] Tree
Tree PLOT - Tree - Nos Of Trees No. 2 0 Failed
[-] Parking
Total Parking In Area Sq.Mt. - - 0.00 OK
[-] Layout Parking
Layout Parking PLOT - Area Sq.Mt. - NA OK
[-] PWork to Plot SetBack
Distance Between Abutting Road and
S-1 (F)...Building Max
Building Minimum SetBack... RESV Mt. 3.00 - 3.49 OK
Setback
ROAD WIDTH RULE
[-] Buildingwise SetBack
Front Yard Minimum SetBack Mt. 3.00 - 3.50 OK
S-1 (F)...Building Max Rear Yard Minimum SetBack Mt. 1.50 - 10.56 OK
Setback Side1 Yard Minimum SetBack Mt. 1.00 - 7.16 OK
Side2 Yard Minimum SetBack Mt. 1.00 - 1.10 OK
[-] Building Height
Height (From Ground LVL) Mt. 34.58 6.65 OK
Height (From Street LVL) Mt. 6.65 OK
S (F)
Total height (Upto The Top Most Point of
Mt. 6.65 OK
The Building)
[-] Floor Height
S (F) Plinth - Height Mt. 0.45 OK
Plinth - Room Height Mt. NA - 0.45 OK
Plinth - Head Room Mt. - - 0.45 OK
Ground Floor - Height Mt. 3.10 OK
Ground Floor - Room Height Mt. 3.00 - 3.00 OK
Ground Floor - Head Room Mt. - - 2.46 OK

https://ibpms.kerala.gov.in/AutoDCR.Common2/CommonPages/printReport.aspx?iProposalId=143632&iVal=1 3/8
8/22/23, 2:46 PM AutoDCR - CheckList

First Floor - Height Mt. 3.10 OK


First Floor - Room Height Mt. - - 3.00 OK
First Floor - Head Room Mt. - - 2.61 OK
[-] Existing FSI & Built Up Area
GROUND FLOOR PLAN - Single Family
Mt. - 133.00 110.43 OK
Dwelling Existing FSI Area
S (F)
GROUND FLOOR PLAN - Single Family
Mt. - 133.00 110.43 OK
Dwelling Existing Built Up Area
[-] Disabled Checks
Entrance Ramp No of Provisions No 1.00 0.00 Failed
[-] Balcony Details
GROUND FLOOR PLAN - SERVICE
S (F) Mt. - 2.07 OK
VERANDAH - Width
[-] Stair Count Details
GROUND FLOOR PLAN - Number Of
No. 1 1 OK
Common Stair(s)
GROUND FLOOR PLAN - Number Of Fire
No. NA NA OK
Stair(s)
S (F)
FIRST FLOOR PLAN - Number Of
No. 1 1 OK
Common Stair(s)
FIRST FLOOR PLAN - Number Of Fire
No. NA NA OK
Stair(s)
[-] Stair Details
GROUND FLOOR PLAN - OPEN
Mt. 1.200 0.850 Failed
STAIRCASE - Flight Width
GROUND FLOOR PLAN - OPEN
Mt. 0.300 0.250 OK
STAIRCASE - Tread Width
GROUND FLOOR PLAN - OPEN
Mt. 0.150 0.282 Failed
STAIRCASE - Riser Height
GROUND FLOOR PLAN - OPEN
No. - 8 OK
STAIRCASE - Riser No. On Flight
GROUND FLOOR PLAN - OPEN
Mt. NA NA OK
STAIRCASE - Cabin Ht.
S (F)
FIRST FLOOR PLAN - OPEN STAIRCASE
Mt. NA 0.850 OK
- Flight Width
FIRST FLOOR PLAN - OPEN STAIRCASE
Mt. NA 0.250 OK
- Tread Width
FIRST FLOOR PLAN - OPEN STAIRCASE
Mt. - 0.282 OK
- Riser Height
FIRST FLOOR PLAN - OPEN STAIRCASE
No. - 8 OK
- Riser No. On Flight
FIRST FLOOR PLAN - OPEN STAIRCASE
Mt. NA NA OK
- Cabin Ht.
[-] Stair Exit Width Details
GROUND FLOOR PLAN - Exit Width Mt. NA 0.850 OK
S (F)
FIRST FLOOR PLAN - Exit Width Mt. NA 0.850 OK
[-] Accessory Use Details
PLOT - - Mercantile/Commercial - ResiComm
Sq.Mt. NA - 2.09 OK
Building - S.TANK - Area
- - Mercantile/Commercial - ResiComm
Mt. NA - 1.08 OK
Building - S.TANK - Width
- - Mercantile/Commercial - ResiComm
Mt. - 1.93 OK
Building - S.TANK - Depth
- - Mercantile/Commercial - ResiComm
Mt. NA - NA OK
Building - S.TANK - Height
- - Mercantile/Commercial - ResiComm
Sq.Mt. OK
Building - S.TANK - Area Add Into FSI
- - Mercantile/Commercial - ResiComm
Sq.Mt. NA - 1.73 OK
Building - G.PIT - Area

https://ibpms.kerala.gov.in/AutoDCR.Common2/CommonPages/printReport.aspx?iProposalId=143632&iVal=1 4/8
8/22/23, 2:46 PM AutoDCR - CheckList

- - Mercantile/Commercial - ResiComm
Mt. NA - 1.08 OK
Building - G.PIT - Width
- - Mercantile/Commercial - ResiComm
Mt. - 1.60 OK
Building - G.PIT - Depth
- - Mercantile/Commercial - ResiComm
Mt. NA - NA OK
Building - G.PIT - Height
- - Mercantile/Commercial - ResiComm
Sq.Mt. OK
Building - G.PIT - Area Add Into FSI
- - Mercantile/Commercial - ResiComm
Building - RAIN WATER HARVESTING Sq.Mt. NA - 1.57 OK
(3929.30 ltr)-1 - Area
- - Mercantile/Commercial - ResiComm
Building - RAIN WATER HARVESTING Mt. NA - 0.94 OK
(3929.30 ltr)-1 - Width
- - Mercantile/Commercial - ResiComm
Building - RAIN WATER HARVESTING Mt. - 1.68 OK
(3929.30 ltr)-1 - Depth
- - Mercantile/Commercial - ResiComm
Building - RAIN WATER HARVESTING Mt. NA - NA OK
(3929.30 ltr)-1 - Height
- - Mercantile/Commercial - ResiComm
Building - RAIN WATER HARVESTING Sq.Mt. OK
(3929.30 ltr)-1 - Area Add Into FSI
- - Mercantile/Commercial - ResiComm
Sq.Mt. NA - 0.41 OK
Building - GWRS - Area
- - Mercantile/Commercial - ResiComm
Mt. NA - 0.44 OK
Building - GWRS - Width
- - Mercantile/Commercial - ResiComm
Mt. - 0.95 OK
Building - GWRS - Depth
- - Mercantile/Commercial - ResiComm
Mt. NA - NA OK
Building - GWRS - Height
- - Mercantile/Commercial - ResiComm
Sq.Mt. OK
Building - GWRS - Area Add Into FSI
[-] Accessory Use Dist Details
Distance From Plot Boundary Mt. 1.20 3.66 OK
S.TANK
Distance From Building Mt. NA 12.94 OK
Distance From Plot Boundary Mt. 1.20 6.10 OK
WELL
Distance From Building Mt. NA 1.07 OK
[-] Accessory Use No Details
Rain Water Harvesting - No No. 1 - 1 OK
PLOT Septic Tank - No No. 1 - 1 OK
Ground water recharging system - No No. 1 - 1 OK
[-] RainWater Harvesting Storage Details
S (F) Rain Water Harvesting - Capacity Ltrs. 3335.00 - OK
Total - - Capacity Sq.mt. 3335.00 3929.30 OK
[-] Ramp Details
S (F) - GROUND FLOOR PLAN - Ramp
No. NA NA OK
No.
Ramp No.
S (F) - GROUND FLOOR PLAN - Ramp
No. 1 0 Failed
for Handicapped
[-] Miscellanies Checks
No Rule Status
For Self Certification Proposal, No proposal other than Low Risk for Group F and
1 G1 Building having BUA upto 100 sq.mt., Building height upto 7 mt. having Failed
max. 2 floors shall be allowed
Access to Main Road is not provided for S-1 (F) Please PROVIDE ACCESS TO
BUILDING FROM ACCESS ROAD {AS PER KERALA MUNICIPALITY BUILDING
2 Failed
RULES 2019 EDITION AND (AMENDMENT) RULES DATED 24TH SEPT,
2020,33(1) 6TH PROVISON RULE NO 3A, 3B, 3C, 5, 6, 7 ETC. OF KMBR 1999}
[-] Room Details
  All Rooms are as per Rule in Room Checking

https://ibpms.kerala.gov.in/AutoDCR.Common2/CommonPages/printReport.aspx?iProposalId=143632&iVal=1 5/8
8/22/23, 2:46 PM AutoDCR - CheckList

NOTE : Based on the aforesaid permission the applicant reserves the rights to commence the construction
from the day of issuance. Nevertheless; in case, for procuring the aforesaid permission, any document or
system configuration for rules or information or parameters or drawings provided or attached is found to
be incorrect or inconsistent with respect to prevailing bye-laws, by any authority or otherwise, the
permission granted shall be considered as lapsed.Accuracy of Scrutiny Report and Drawing is subject to
accuracy of end-user provided data, 3rd party software/hardware/services, etc. SoftTech Engineers Ltd. is
not liable for any damages which may arise from use, or inability to use the Application.

[-] Rules
Topic Rule
Plot Level
No minimum Plot size defined {As per KERALA MUNICIPALITY BUILDING RULES 2019 Edition
and (Notification) Rules Dated 24th Sept, 2020, Chapter VII, Rule No. 51} In case of
Plot Area SubDivision,the area of any newly subdivided plot,reconstituted plot or building plot shall be
not less than 125 square meters with an average width of 6.00 meters. Every plot shall have
a frontage of not less than 4 meters on any abutting street {Rule No. 27}
For Building in Group A2,B,C,D,E,F having total floor area upto 300sq.mt., Mini. Width of
Main Road Width Access 1.20mt. is to be checked {As per KERALA MUNICIPALITY BUILDING RULES 2019
Edition and (Notification) Rules Dated 24th Sept, 2020, Chapter IV, Rule No. 28, Table 8}
No minimum Plot size defined {As per KERALA MUNICIPALITY BUILDING RULES 2019 Edition
and (Notification) Rules Dated 24th Sept, 2020, Chapter VII, Rule No. 51} In case of
Plot Frontage SubDivision,the area of any newly subdivided plot,reconstituted plot or building plot shall be
not less than 125 square meters with an average width of 6.00 meters. Every plot shall have
a frontage of not less than 4 meters on any abutting street {Rule No. 27}
For Group A1 Occupancy,Max. Permissible Coverage shall be 65% {As per KERALA
Covered Area MUNICIPALITY BUILDING RULES 2019 Edition and (Notification) Rules Dated 24th Sept,
2020, Rule No. 27, Table 6}
(1) For Group A1 Occupancy,Max. Permissible FAR shall be 3.0 {As per KERALA
MUNICIPALITY BUILDING RULES 2019 Edition and (Notification) Rules Dated 24th Sept,
FSI Area 2020, Chapter V, Rule No. 27, Table 6}
(2) No Additional FAR is allowed {As per KERALA MUNICIPALITY BUILDING RULES 2019
Edition and (Notification) Rules Dated 24th Sept, 2020, Chapter V, Rule No. 27, Table 6}
(1) For Group A1 Occupancy,Max. Permissible FAR shall be 3.0 {As per KERALA
MUNICIPALITY BUILDING RULES 2019 Edition and (Notification) Rules Dated 24th Sept,
Consumed FSI 2020, Chapter V, Rule No. 27, Table 6}
(2) No Additional FAR is allowed {As per KERALA MUNICIPALITY BUILDING RULES 2019
Edition and (Notification) Rules Dated 24th Sept, 2020, Chapter V, Rule No. 27, Table 6}
For all type of building other than single family residential, Planting of trees shall be made at
the rate of minimum of one tree per 450 sq.m of plot area for plots exceeding 450 sq. metres
Tree Number
of area.{As per KERALA MUNICIPALITY BUILDING RULES 2019 Edition and (Notification)
Rules Dated 24th Sept, 2020, Rule No. 76.3}
Parking Allownce No Rule Define.
(1) For Group F building, built up area not exceeding 200.0 sq.mt. and building upto 10
meters in height shall have a front yard 3.0 mt (Mini. 1.8 mt.). side yard 1.0 mt., rear yard
1.5 mt. (Mini. 1.0 mt.) {As per KERALA MUNICIPALITY BUILDING RULES 2019 Edition and
(Notification) Rules Dated 24th Sept, 2020, Table 4 or 4A}
SetBack Rule
(2) No person shall construct any building other than compound wall within 3 mts. from any
plot boundary abutting national highways, state highways or other roads notified under
section 383A of Kerala Municipality act 1994. {As per KERALA MUNICIPALITY BUILDING
RULES 2019 Edition and (Notification) Rules Dated 24th Sept, 2020, Rule No. 23}
For Group F building, built up area not exceeding 200.0 sq.mt. and building upto 10 meters in
height shall have a front yard 3.0 mt (Mini. 1.8 mt.). side yard 1.0 mt., rear yard 1.5 mt.
Margin Rule
(Mini. 1.0 mt.) {As per KERALA MUNICIPALITY BUILDING RULES 2019 Edition and
(Notification) Rules Dated 24th Sept, 2020, Table 4 or 4A}
(1) No rule defined
(2) No leech pit, sock pit, refuse pit, earth closet or septic tank shall be allowed within 1.20
metres distance from the plot boundaries.{As per KERALA MUNICIPALITY BUILDING RULES
2019 Edition and (Notification) Rules Dated 24th Sept, 2020, Rule No. 41} S.TANK
Accessory Use Dist
(3) No rule defined
(4) No Well shall be allowed within 1.20 metres distance from the plot boundaries.{As per
KERALA MUNICIPALITY BUILDING RULES 2019 Edition and (Notification) Rules Dated 24th
Sept, 2020, Rule No. 41} WELL
Building Level
Building Height The maximum height of the building or part thereof shall not exceed twice the width of the
street abutting the plot plus twice the width of the yard from the building to the abutting
https://ibpms.kerala.gov.in/AutoDCR.Common2/CommonPages/printReport.aspx?iProposalId=143632&iVal=1 6/8
8/22/23, 2:46 PM AutoDCR - CheckList
street {As per KERALA MUNICIPALITY BUILDING RULES 2019 Edition and (Notification) Rules
Dated 24th Sept, 2020, Rule No.24(1)}
(1) No rule defined
(2) For any Building,the height of General floor shall not be less than 3.0 mt. {As per KERALA
MUNICIPALITY BUILDING RULES 2019 Edition and (Notification) Rules Dated 24th Sept,
2020, Chapter V}
(3) For any Building,the height of General floor shall not be less than 3.0 mt. {As per KERALA
MUNICIPALITY BUILDING RULES 2019 Edition and (Notification) Rules Dated 24th Sept,
2020, Chapter V}
Floor Height
(4) For any Building,the height of General floor shall not be less than 3.0 mt. {As per KERALA
MUNICIPALITY BUILDING RULES 2019 Edition and (Notification) Rules Dated 24th Sept,
2020, Chapter V}
(5) No Rule Defined.
(6) No Rule Defined.
(7) No Rule Defined.
(8) No Rule Defined.
Existing FSI &
Builtup Area Check Existing FSI area & built up area as per drawing are not more than actual provided in
as per approved approved plan.
plan.
Disabled Checks -NA-
Balcony No Rule defined.
(1) For occupancy other than Residential,Min. 1 Staircase shall be provided for Building
having 3 floors {As per KERALA MUNICIPALITY BUILDING RULES 2019 Edition and
(Notification) Rules Dated 24th Sept, 2020, Rule No. 35}
StairCase Count
(2) Min. 1 Staircase shall be provided for Building having 3 floors {As per KERALA
MUNICIPALITY BUILDING RULES 2019 Edition and (Notification) Rules Dated 24th Sept,
2020, Rule No. 35}
(1) Any(except family residential buildingsnot more than 3 floors),Width of the Stair case
shall be mini. 1.2 mt.,Maximum riser 0.15 mt. and Minimum tread 0.30 mt. {As per KERALA
MUNICIPALITY BUILDING RULES 2019 Edition and (Notification) Rules Dated 24th Sept,
2020, Rule No. 35}
(2) 0.0
(3) ; No rule defined
(4) No rule defined for family residential buildings upto 3 floors {As per KERALA
MUNICIPALITY BUILDING RULES 2019 Edition and (Notification) Rules Dated 24th Sept,
StairCase
2020, Rule No. 35}
(5) 0.0
(6) ; No rule defined
(7) No Required to check.
(8) For Group A1 Residential building, Occupants per unit exit width shall be 12.5 of total
builtup area per person and no of occupants per 25 unit exit width of stairway.{As per
KERALA MUNICIPALITY BUILDING RULES 2019 Edition and (Notification) Rules Dated 24th
Sept, 2020, Rule No. 37, Table 16 and Table 17}
(1) For Group F,Required Capacity Shall be 25 Lts/sq.mt. of Coverage area. {As per KERALA
Accessory Use MUNICIPALITY BUILDING RULES 2019 Edition and (Notification) Rules Dated 24th Sept,
Storage 2020, Rule No. 41} Rain Water Harvesting
(2) -
All buildings under occupancy groups A2, B,C,D, E,F and J which have access to the public
and all apartment buildings/residential flats under occupancy group A1 shall be provided
Ramp No. building shall have easy access to the main entrance through a Handicap ramp. {As per
KERALA MUNICIPALITY BUILDING RULES 2019 Edition and (Notification) Rules Dated 24th
Sept, 2020, Rule No. 42.1}
Plot / Building Level
(1) No rule defined
(2) No leech pit, sock pit, refuse pit, earth closet or septic tank shall be allowed within 1.20
metres distance from the plot boundaries.{As per KERALA MUNICIPALITY BUILDING RULES
2019 Edition and (Notification) Rules Dated 24th Sept, 2020, Rule No. 41} S.TANK
(3) No rule defined
Accessory Use (4) No need to check distance from Building or Plot Boundary G.PIT
(5) No rule defined
(6) No need to check distance from Building or Plot Boundary RAIN WATER HARVESTING
(3929.30 ltr)-1
(7) No rule defined
(8) No need to check distance from Building or Plot Boundary GWRS
Accessory Use (1) Rain water storage Arrangement is mandatory for any type of Building {As per KERALA
Number MUNICIPALITY BUILDING RULES 2019 Edition and (Notification) Rules Dated 24th Sept,
2020, Rule No. 41}
(2) Every new building of built-up area exceeding 100 sq.metres shall be provided with septic
https://ibpms.kerala.gov.in/AutoDCR.Common2/CommonPages/printReport.aspx?iProposalId=143632&iVal=1 7/8
8/22/23, 2:46 PM AutoDCR - CheckList

tank.{As per KERALA MUNICIPALITY BUILDING RULES 2019 Edition and (Notification) Rules
Dated 24th Sept, 2020, Rule No. 41}
(3) Ground water recharging system is mandatory for any type of Building {As per KERALA
MUNICIPALITY BUILDING RULES 2019 Edition and (Notification) Rules Dated 24th Sept,
2020, Rule No. 41}
Building Level (Rooms)
Family residential buildings with not more than three floors,Building in Small Plots,Row Type
Building and Building construction under Approved Schemes shall be exempted from the
Bed Room provisions of Dimension with regard to Building parts,light and ventilation {As per KERALA
MUNICIPALITY BUILDING RULES 2019 Edition and (Notification) Rules Dated 24th Sept,
2020, Chapter IV, Rule No. 31}
Family residential buildings with not more than three floors,Building in Small Plots,Row Type
Building and Building construction under Approved Schemes shall be exempted from the
Drawing Room provisions of Dimension with regard to Building parts,light and ventilation {As per KERALA
MUNICIPALITY BUILDING RULES 2019 Edition and (Notification) Rules Dated 24th Sept,
2020, Chapter IV, Rule No. 31}
Family residential buildings with not more than three floors,Building in Small Plots,Row Type
Building and Building construction under Approved Schemes shall be exempted from the
Hall provisions of Dimension with regard to Building parts,light and ventilation {As per KERALA
MUNICIPALITY BUILDING RULES 2019 Edition and (Notification) Rules Dated 24th Sept,
2020, Chapter IV, Rule No. 31}
Family residential buildings with not more than three floors,Building in Small Plots,Row Type
Building and Building construction under Approved Schemes shall be exempted from the
Kitchen provisions of Dimension with regard to Building parts,light and ventilation {As per KERALA
MUNICIPALITY BUILDING RULES 2019 Edition and (Notification) Rules Dated 24th Sept,
2020, Chapter IV, Rule No. 31}
Family residential buildings with not more than three floors,Building in Small Plots,Row Type
Building and Building construction under Approved Schemes shall be exempted from the
Puja provisions of Dimension with regard to Building parts,light and ventilation {As per KERALA
MUNICIPALITY BUILDING RULES 2019 Edition and (Notification) Rules Dated 24th Sept,
2020, Chapter IV, Rule No. 31}
Shop (ac) No rule defined
Family residential buildings with not more than three floors,Building in Small Plots,Row Type
Building and Building construction under Approved Schemes shall be exempted from the
Store provisions of Dimension with regard to Building parts,light and ventilation {As per KERALA
MUNICIPALITY BUILDING RULES 2019 Edition and (Notification) Rules Dated 24th Sept,
2020, Chapter IV, Rule No. 31}
Family residential buildings with not more than three floors,Building in Small Plots,Row Type
Building and Building construction under Approved Schemes shall be exempted from the
Toilet provisions of Dimension with regard to Building parts,light and ventilation {As per KERALA
MUNICIPALITY BUILDING RULES 2019 Edition and (Notification) Rules Dated 24th Sept,
2020, Chapter IV, Rule No. 31}

https://ibpms.kerala.gov.in/AutoDCR.Common2/CommonPages/printReport.aspx?iProposalId=143632&iVal=1 8/8

You might also like