POWER TRANSMISSION & DISTRIBUTION TRAINER (Model : XPO-SPS/TLD)
Table top control panel Rack &
under table Distri. X'mer, TL1 &
www.anshumantech.net/.com
RLC load panel
NOTE: This is part of XPO-SPS Training System.
SALIENT FEATURES Emergency stop mushroom switch is provided with security
key lock on the profile rack.
This setup is used for transmission line study for short as well
Facilitates easy and safe wiring by students due to use of
as long line Pi model, ferranti effects, load regulation /
4mm sturdy Shrouded banana patch cords and shrouded
efficiency calculations, symmetric/asymmetric fault study. socket arrangements for high voltage circuits
This setup also covers protection of transmission line using
Each panel has ABS molded plastic sturdy enclosure, and
multi function numeric distance protection relay and of colorful screwless overlays showing circuits diagrams & its
distribution transformer using multi function numeric connection tag numbers for easy understanding and
transformer protection relay. connection
The protection relays are connected to RTU/SCADA over Useful for Under Graduate Practicals, Post Graduate Projects
RS485 to display all fault records on SCADA screen. and Research Purpose.
Set of Instructor Guide & Student Workbook.
Technical Specifications Measure V. I., Hz, Pf, KVA, KW, KWH
XPO- SPS/TLD trainer can work in standalone mode as well as Modbus RTU RS 485 for RTU/SCADA interface.
in conjunction with HMI, RTU SCADA software and consists of VAR Compensation panel (dual panel) (EMT43) X 1 No.
following panels: Consisting of VAR compensating capacitors of 2, 4, 6, 8, 10 &
Input 3 phase DOL Starter panel (EMT1) X 1 No 15µF each of 3 nos with 3 pole 7 way switch for selection.
4 pole MCB of 415 V/4A. Differential Relay (Transformer protection) panel (EMT
DOL 16A Contactor with 24DCV / 11VA COIL 47C) X 1 No.
Bimetallic thermal O/L relay with range 2.5A - 6A Protections: Differential, Over current, Under/Over voltage,
RYB inputs indicators. Under/Over frequency, Reverse power, Earth fault.
9 pin D (M) connector for RTU/SCADA interface. 9 pin D (M) connector to interface with RTU/SCADA for
Manual start / stop with local trip contact
automation.
Power ON LED indicator
Modbus RTU RS 485 for RTU/SCADA interface.
CT panel (EMT48) ) X 2 No.
Power Engineering
FWD-OFF-REV, Switch Panel (EMT 4A) X 1 No.
Consist of 5/5 Amp. CT 6 Nos.
FWD/REV, 3 pole 3 way switch with center OFF, 6A/440V.
Primary side of CTs are brought on 3 x 2 x 2 SBS-5 sockets.
3 Phase Bidirectional Power cum Energy meter panel (EMT
34) X 3 Nos. Secondary side of CTs are Star connected in group of 3 &
brought out on 4 x 2 SBS-5 sockets
Bidirectional Multifunction
Distance protection Relay panel (EMT 53) X 1 No.
3 phase 3/4 wire, 415VAC, CT Input 5A
Protections: Distance, Over current, Under/Over voltage, Earth
LCD/LED display, Aux. supply 230V, 45-65Hz,5W
fault.
Auto reclose function of relay Accessories:
9 pin D (M) connector to interface with RTU/SCADA for a) Tables for Transmission & Distribution Setup : 1 no. consists of
automation. Pi type frame, under trolley.
Modbus RTU RS 485 for RTU/SCADA interface. i) Frame: 45X45 aluminum profile (Heavy duty) Colour: anodized
415/110VAC, 50VA PT panel (EMT 54) X 1 No. white.
Consisting of potential transformer,
ii) Table top material/colour: The nova pan or Rubber wood with
white/Silver gray with smooth finish veneer finish table top (25
Input 415VAC, star connected, Output 110VAC, star
mm thickness) with removable slot cover (900X500mm).
connected, 50VA.
iii) Under Trolley: Located under individual setup table to house
37 pin D(M) to 9 pin D(F) converter panel (EMT 62) X 1 No.
respective load panel, transmission line panel variac panel,
Consist of 37 pin D type male 1 no., 9 pin D type male 1 no.
transformer etc as applicable.
9 pin D type female connectors 9 nos. iv) Dimension: Table: 1450 mm (L) X 750 mm (W) X 760 mm (H).
Power ON LED. Under Trolley: 1200X700X185mm
5 pin to shrouded socket converter panel (EMT 63) X 2 Nos. v) Caster wheels: Four sturdy castor wheels with locking
Consist of 5 pin 3 phase, 5 wires industrial female socket to mechanism are provided so that table can be positioned
www.anshumantech.net/.com
connect 415VAC 3 phase supply. conveniently.
Shrouded banana sockets 18 nos to extend the 3 phase supply b) Cables:
into individual setups. i) 9 pin D male to 9 pin D female with 9 core cable, length up to 4
It's used as bidirectional 3 phase extension board between two meter - 4 nos.
setups. ii) 37 pin D male to 37 pin D female patch cable, length = 4 meters
Table top panels: -1 no.
iii) RS485 patch cable: 6 pin mini DIN male to 6 pin mini DIN male,
Distribution transformer Panel (EMT54D) X 1 No.
length up to 4 meters - 5 nos.
3 phase power transformer with connection group YY11,
c) Signal tower: 4 nos. of fixed function lamps and 1 Alarm sound
Input 415VAC, Output 415VAC, 3KVA,
all mounted one above another in classic bayonet system by
Secondary winding with tapping at ±2.5% and ±5%. means of a simple half rotation manual operation, mounted on
Transmission line Panel (EMT38 & 42E) right vertical member of the TLD rack and are driven from 24V
Table Top Panel consisting of: DC output of PLC using 37 pin D converter panel. The signal
Simulated model for transmission line (250kms) using R(10 tower is used to indicate following conditions-
ohm/600W), L(0.15H/5A) & C (2.2uF/630V) 6 No. each Red lamp paralleled with sounder - When any Relay trips,
component. Red lamp will flash at 0.75Hz and the alarm is sounded until
Simulated model for medium/long length transmission line for fault accept button is pressed.
pi model. Orange lamp - When an Emergency stop button is pressed,
Simulated model for medium/long length transmission line for T
the 3 Ph. supply of Grid and Generator is made OFF and Orange
model lamp will flash at 0.75Hz until fault accept button is pressed.
Green lamp - When Default state is pressed Green lamp will
Fault resistor 100ohm/600W.
ON for 1sec & OFF for 3sec which indicate all CB's and
Multi pin heavy duty connector 32 pin & 24 pin to establish
isolators OFF. When any of the CB or isolator is switched ON
control from RTU/SCADA.
then green light will flash at 0.75Hz indicating SCADA in
RLC load Panel (EMT42A/B/C) X 1 No.
operation.
3 nos of 600W resistors with switch selectable 6 nos of taps at Blue lamp - When Grid is AUTO synchronized with Generator
100, 112, 150, 175, 200 & 225 ohm. the Blue will flash at 0.75Hz.
3 nos of inductor 1.5H/1A with switch selectable 6 nos of taps at List of experiments:
0.3, 0.6, 0.75, 0.9, 1.2 & 1.5H. i) Study of No load test and Ferranti effects on transmission line.
Capacitors 440VAC rating (3 nos, one per phase) with switch ii) Load test and calculation of efficiency, regulation and power
selectable 7 nos of value of 2, 5, 10, 15, 20, 30 & 50µF. flow in pi model of TL.
Multi pin heavy duty connector 32 pin & 24 pin to establish iii) Load test and calculation of efficiency, regulation and power
Power Engineering
control from RTU/SCADA. flow in short model of TL
Mechanical Dimension (mm) / Wt. (Kg): iv) Study of symmetrical and asymmetrical faults on transmission
Rack: 1170(L) x 300(W) x 990(H) / Net Wt.: 65, Gross Wt.: 73. line.
TL1: 600(L) x 385(W) x 500(H) / Net Wt.: 103 v) Study of distance protection using distance relay.
RLC Load panel: 600(L) x 275(W) x 500(H) / Net Wt.: 60
vi) Study of Auto reclose function of distance relay.
vii) Study of Distribution transformer protection for differential &
Distri. X'mer: 770(L) x 275(W) x 435(H) / Net Wt.: 53
over current faults.