AC 01.2/ACExC 01.2/ACV 01.2/ACVExC 01.
Wiring diagram code
                                                                        Extract of wiring diagram code
                                                                        Position    1      2     3      4     5      6     7      8     9   10   11   12   13   14
 Position    I/O interface                                              TPC         A      –     0      A     1      –     1      C     1   –    A    0    0    0
             Profibus DP                                                TPC         A     A      0      0     0      –     1      A     1   –    A    0    0    0
     1       Controls type
             A       AC 01.2/ACExC 01.2
             H       ACV 01.2/ACVExC
     2       Interface to the distributed control system
             –       I/O interface
             A       Profibus DP
             C       Modbus RTU/Modbus TCP/IP
             F       Foundation Fieldbus
             I       HART Connection Type: Actuator
             J       HART Current Output
             N       Profinet
     3       Analogue inputs
             0       Without
             1       4 – 20 mA for positioner
             A       With 2 free analogue inputs
     4       Digital inputs
             A       CLOSE, OPEN, STOP, EMERGENCY
             B       With positioner: MODE, CLOSE, OPEN, STOP, EMERGENCY
             0       Without
             1       With 4 free digital inputs
             2       With 6 inputs: MODE, CLOSE, OPEN, STOP, EMERGENCY, I/O interface
             4       With 5 inputs: CLOSE, OPEN, STOP, EMERGENCY, I/O interface
     5       Output contacts, position and torque feedback signals (0/4 – 20 mA)
             1 / D 5 NO contacts, 1 change-over contact, position feedback signal
                   torque feedback signal (in combination with MWG)
             0       Without
     6       Additional equipment
             –       Without
             K       Profinet, 2xIEEE 802.3
     7       Local controls
             1       Push buttons OPEN, STOP, CLOSE, RESET, selector switch LOCAL - OFF - REMOTE, display,
                     5 indication lights
     8       Auxiliary voltage for supply of digital inputs
             A       Without
             C       24 V DC
     9       Switchgear
             1       Reversing contactors max. AUMA power class A3 (refer to Electrical data SA .2/SAR .2 with 3-phase AC
                     motor)
             2       Thyristors max. AUMA power class A3 (refer to Electrical data SA .2/SAR .2 with 3-phase AC motor)
             3       Thyristors max. AUMA power class B3 (refer to Electrical data SA .2/SAR .2 with 3-phase AC motor)
             4       Thyristors with additional tripping max. AUMA power class B2 (refer to Electrical data SA .2/SAR .2 with
                     3-phase AC motor)
             5       Thyristors with additional tripping max. AUMA power class B3 (refer to Electrical data SA .2/SAR .2 with
                     3-phase AC motor)
             E       Power electronics 1-ph1)
             F       Power electronics 3-ph1)
1) Refer to notes on page 2.
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
                                                          Y005.293/003/en            Issue 1.18        Page 1/2
AC 01.2/ACExC 01.2/ACV 01.2/ACVExC 01.2
Wiring diagram code
                                                                        Extract of wiring diagram code
                                                                        Position    1      2     3      4     5      6     7      8     9   10   11   12   13   14
 Position    I/O interface                                              TPC         A      –     0      A     1      –     1      C     1   –    A    0    0    0
             Profibus DP                                                TPC         A     A      0      0     0      –     1      A     1   –    A    0    0    0
       10    Motor protection evaluation
             –       Thermoswitches (standard for AC 01.2), refer to wiring diagram TPA
             1       Thermoswitch with thermal overload relay
             –       PTC thermistors with tripping device (standard for ACExC), refer to TPA terminal plan
       11    Heater
             A       Internally supplied within the switch compartment of the actuator
 12 – 14 Control elements
             000     Without
             A20     KP suitable wiring
             5E0     Modbus TCP/IP
             5EF     Modbus TCP/IP Ex
             410     Profibus Ex
             460     Profibus Ex, KP suitable wiring
 Notes on tables on page 1
 1)	                                           In combination with ACV 01.2 only.
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
                                                          Y005.293/003/en            Issue 1.18        Page 2/2