PROJECTS NAME:-
SUMMARY
S. No DESCRIPTION
1 FINISHING WORKS -
Total -
-
GRANT TOTAL
PROJECTS NAME:-
SUMMARY OF CIVIL WORKS
AMOUNT
S.NO. DESCRIPTION
FINISHING WORKS
STONE WORK
1 0.00
MARBLE WORK
2 0.00
3 WOOD WORK & PVC WORK 0.00
STEEL WORK
4 0.00
FLOORING/ DADO
5 0.00
FINISHING (Plaster & Painting Work)
6 0.00
ALUMINUM WORKS
7 0.00
WATER PROOFING
8 0.00
TOTAL
0.00
GRAND TOTAL
0.00
Abstract sheet
PROJECTS NAME:-
S.NO. DESCRIPTION UNIT QTY RATE AMOUNT
STONE WORK
31 Providing and fixing structural steel frame (for dry cladding
with 30 mm thick gang saw cut with machine cut edges sand
stone) on walls at all heights using M.S. square/ rectangular
tube in the required pattern as per architectural drawing,
including cost of cutting, bending, welding etc. The frame work
shall be fixed to the wall with the help of M.S. brackets/ lugs
of angle iron/ flats etc. which shall be welded to the frame
and embedded in brick wall with cement concrete block 1:2:4
(1 cement :2 coarse sand :4 graded stone aggregate 20 mm
nominal size) of size 300x230x300 mm, including cost of
necessary centring and shuttering and with approved
expansion hold fasteners on CC/RCC surface, including drilling
necessary holes. Approved cramps/ pins etc. shall be welded
to the frame work to support stone cladding, the steel work
will be given a priming coat of Zinc primer as approved by
Engineer-in-charge and painted with two or more coats of
epoxy paint (Shop drawings shall be submitted by the
contractor to the Engineer-in-charge for approval before
execution). The frame work shall be fixed in true horizontal &
vertical lines/planes. (Only structural steel frame work shall
be measured for the purpose of payment, stainless steel
cramps shall be paid for separately and nothing extra shall be
paid).
kg 134.75 0.00
32 Providing and fixing adjustable stainless steel cramps of
approved quality , required shape and size, adjustable with
stainless steel nuts, bolts and washer (total weight not less
than 260 gms), for dry stone cladding fixed on frame work at
suitable location, including making necessary recesses in stone
slab, drilling required holes etc complete as per direction of
the Engineer-in-charge
each 217.15 0.00
33 Providing and fixing Glass Reinforced Concrete (G.R.C) Screens
in THICKNESS (50-60mm), approved size, pattern, design and
color . The Screens should be made from ‘53 grade’ White
Portland Cement , Quartz, Fine Silica Sand, Alkali Resistant
Glass Fiber, Super Plasticizers Polymers t and U.V resistant
Synthetic inorganic pigments should be used for
pigmentation . The material casting should take place in
Synthetic Rubber / FRP Mould complete in all respect as per
direction of Engineer - incharge Framework for fixing shall be
paid separately.
sqm 0.00
TOTAL STONE WORK 0.00
MARBLE WORK
34 Providing and fixing 18mm thick gang saw cut mirror polished
( premoulded and prepolished) machine cut for kitchen
platforms, vanity counters, window sills , facias and similar
locations of required size of approved shade, colour and
texture laid over 20mm thick base cement mortar 1:4 (1
cement : 4 coarse sand) with joints treated with white cement,
mixed with matching pigment, epoxy touch ups, including
rubbing, curing, moulding and polishing to edge to give high
gloss finish etc. complete at all levels.
Granite of any colour and shade
Area of slab over 0.50 sqm sqm 3113.30 0.00
35 Providing edge moulding to 18 mm thick marble stone
counters, Vanities, etc. including machine polishing to edge to
give high gloss finish, etc. complete as per design approved by
Engineer-in-Charge.
Granite work
metre 245.70 0.00
36 Extra for providing opening of required size & shape for wash
basins/kitchen sink in kitchen platform, vanity counters and
similar location in marble/Granite/stone work including
necessary holes for pillar taps etc including modlding, rubbing
and polishing of cut edges etc complete.
each 427.95 0.00
37 Providing and laying flamed finish Granite stone flooring in
required design and patterns, in linear as well as curvilinear
portions of the building all complete as per the architectural
drawings with 18 mm thick stone slab over 20 mm (average)
thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid
and jointed with cement slurry and pointing with white
cement slurry admixed with pigment of matching shade
including rubbing, curing and polishing etc. all complete as
specified and as directed by the Engineer-in-Charge :
Flamed finish granite stone slab Jet Black, Cherry Red, Elite
Brown, Cat Eye or equivalent. sqm 2887.85 0.00
38 Providing and laying Polished Granite stone flooring in
required design and patterns, in linear as well as curvilinear
portions of the building, all complete as per the architectural
drawings, with 18 mm thick stone slab over 20 mm (average)
thick base of cement mortar 1:4 (1 cement : 4 coarse sand),
laid and jointed with cement slurry and pointing with white
cement slurry admixed with pigment of matching shade,
including rubbing, curing and polishing etc. all complete as
specified and as directed by the Engineer-in-Charge.
Polished Granite stone slab jet Black, Cherry Red, Elite Brown,
Cat Eye or equivalent. sqmt 2937.70 0.00
39 Providing and laying Polished Granite stone skirting/dado in
required design and patterns, in linear as well as curvilinear
portions of the building, all complete as per the architectural
drawings, with 18 mm thick stone slab over 12mm (average)
thick base of cement mortar 1:4 (1 cement : 4 coarse sand),
laid and jointed with cement slurry and pointing with white
cement slurry admixed with pigment of matching shade,
including rubbing, curing and polishing etc. all complete as
specified and as directed by the Engineer-in-Charge.
Polished Granite stone slab jet Black, Cherry Red, Elite Brown,
Cat Eye or equivalent. sqmt 0.00
TOTAL MARBLE WORK 0.00
WOOD WORK & PVC WORK
40 Providing and fixing aluminium extruded section body tubular
type universal hydraulic door closer (having brand logo with
ISI, IS : 3564, embossed on the body, door weight upto 36 kg to
80 kg and door width from 701 mm to 1000 mm), with double
speed adjustment with necessary accessories and screws etc.
complete.
Each 388.40 0.00
41 Providing and fixing aluminium sliding door bolts ISI marked
anodised (anodic coating not less than grade AC 10 as per IS :
1868) transparent or dyed to required colour or shade with
nuts and screws etc. complete :
a 300x16 mm Each 212.45 0.00
b 250x16 mm Each 189.20 0.00
42 Providing and fixing aluminium tower bolts ISI marked
anodised (anodic coating not less than grade AC 10 as per IS :
1868 ) transparent or dyed to required colour or shade with
necessary screws etc. complete:
a 300x10 mm Each 99.70 0.00
b 150x10 mm Each 64.30 0.00
43 Providing and fixing aluminium handles ISI marked anodised
(anodic coating not less than grade AC 10 as per IS : 1868)
transparent or dyed to required colour or shade with
necessary screws etc. complete :
125 mm Each 51.10 0.00
44 Providing and fixing aluminium hanging door stopper ISI
marked anodised (anodic coating not less than grade AC 10 as
per IS : 1868) transparent or dyed to required colour or shade
with necessary screws etc. complete
Twin rubber stoppr. Each 38.00 0.00
45 Providing and fixing fire resistant door frame of section 50 x
60mm on horizontal side & 35 x 60 mm on vertical sides
having built in rebate made out of 1.6 mm thick GI sheet ( Zinc
coating not less than 120gm/m²) suitable for mounting 120
min Fire Rated Glazed Door Shutters. The frame shall be filled
with Mineral wool Insulation having density min 96Kg/m³ .
The frame will have a provision of G.I. Anchor fastners 14
nos ( 5 each on vertical style & 4 on horizontal style of size
M10 x 80 ) suitable for fixing in the opening along with
Factory made Template for SS Ball Bearing Hinges of Size
100x89x3mm for fixing of fire rated glazed shutter. The frame
shall be finished with a approved fire resistant primer or
Powder coating of not less than 30 micron in desired shade as
per the directions of Engineer - in- charge . (Cost of SS ball
bearing hinges is excluded).
metre 1260.00 0.00
46 Providing and fixing 60 mm thick glazed fire resistant door
shutters of 120 min Fire Rating confirming to IS:3614 (Part II)
or EN1634-1:1999, tested and certified as per laboratory
approved by Engineer-in-charge, with suitable mounting on
door frame, consisting of vertical styles, top rail & side rail 60
mm x 60 mm wide and bottom rail of 1 10 mm x 60 mm
made out of 1.6mm thick G .I. sheet (zinc coating not less
than 120gm/m²) duly filled mineral wool insulation having
density min 96 kg/m³ and fixing with necessary stainless
steel ball bearing hinges of size 100x89x3mm of approved
make, including applying a coat of approved fire resistant
primer or powder coating not less than 30 micron etc all
complete as per direction of Engineer-in-charge (panelling to
be paid for seperately).
sqm 6839.35 0.00
47 Providing and fixing glazing in fire resistant door shutters,
fixed panels & partitions etc., with G.I. beading made out
of 1.6 mm thick G.I. sheet (zinc coating not less than 120
gm/m²) of size 20x 33 mm screwed with M4 x 38 mm SS
screws at distance 75 mm from the edges and 150 mm c/c ,
including applying a coat of approved fire resistant
primer/powder coating of not less than 30 micron on G .I.
beading, & special ceramic tape of 5 x 20 mm size etc complete
in all respect as per direction of Engineer-in-charge. The glass
shall be clear , toughened, interlayered, non-wired fire
resistant having 11 mm thickness of approved brand with
120 minutes of fire resistance both integrity & radiation
control (EW120) and minimum 15 min of insulation (EI15)
and having a sound reduction of 37dB and L T of 86%.
Glass shall be compliant to class 2(B)2 category of Impact
Resistance as per EN 12600. The glass should be manufactured
in UL & TUV audited Facility and including UL-EU
Certification.The maximum glazing size cannot be more than
1100 mm x 2200 mm (w x h) or 2.42 sq mt s in total area. The
test report for the complete system (Glazed Door or
Partition) will be considered valid only if it contains the stamp
and signature of the authorized signatory from the glass
manufacturer . (Actual glass size is to be measured at site for
payments).
sqm 34058.90 0.00
Calculations
48 Providing and fixing bright /matt finished Stainless Steel
handles of approved quality & make with necessary screws
etc all complete.
125 mm
each 89.70 0.00
49 Supply and installation of single/double leaf Wooden fire
rated doors as per BS:476 Part- 20 & 22 & IS 3614 part-2 for
stability, integrity and thermal insulation. 03 Criteria Wooden
door confirming to IS 277 with the following specification.
Recommended fire door shall have doors tested at CBRI for
maximum rating of 2hrs tested either with or without vision
panel with finished face of 3-4mm thk recon vneer/laminate.
The door shall have an acoustics range from Rw 35 dB to Rw
55 dB tested for airborne sound as per IS-9901(Part III) –
1981, DIN 52210 part IV – 1984, ISO : 140 ( Part III)-1995.The
door frame will be made out of Hardwood(Red Mirandi) of
maximum section 120 x 70mm and coated with VIPER Fire
reatrdent Primer. The rebate shall be of 20mm x 54mm in the
Door Frame to accommodate the shutter . Both frame and
shutter shall be fitted with intumescent Fire seal strips , The
shutter fitted with 20x4mm Fire seal and Frame with 2 no. Fire
seal of size 10x4mm on all the three sides of the Shutter except
bottom. The pasting of the ply/veneer/laminate should be
done using automatic machine and should be free from any
nails or perforations. The cost shall include all necessory
hardware like hinges, lock , sliding bolt , stay etc. complete in
all respect as per direction of Engineer Incharge.
sqm 0.00
Make: Navair/Ecotone/Sukri
TOTAL WOOD WORK & PVC WORK 0.00
STEEL WORK
50 Providing and fixing 1mm thick M.S. sheet door with frame of
40x40x6 mm angle iron and 3 mm M.S. gusset plates at the
junctions and corners, all necessary fittings complete,
including applying a priming coat of approved steel primer.
Using M.S. angels 40x40x6 mm for diagonal braces
sqm 2870.25 0.00
51 Supplying and fixing rolling shutters of approved make, made
of required size M.S. laths, interlocked together through their
entire length and jointed together at the end by end locks,
mounted on specially designed pipe shaft with brackets, side
guides and arrangements for inside and outside locking with
push and pull operation complete, including the cost of
providing and fixing necessary 27.5 cm long wire springs
manufactured from high tensile steel wire of adequate
strength conforming to IS: 4454 - part 1 and M.S. top cover of
required thickness for rolling shutters.
80x1.25 mm M.S. laths with 1.25 mm thick top cover sqm 2316.10 0.00
52 Providing and fixing ball bearing for rolling shutters. each 379.30 0.00
53 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet
box for ceiling fan clamp of internal dia 140mm, 73mm height,
top lid of 1.5mm thick M.S. sheet with its top surface hacked
for proper bonding, top lid shall be screwed into the cast iron/
M.S. sheet box by means of 3.3mm dia. round headed screws,
one lock at the corners. Clamp shall be made of 12mm dia M.S.
bar bent to shape as per standard drawing.
Each 130.10 0.00
54 Steel work welded in built up sections/ framed work, including
cutting, hoisting, fixing in position and applying a priming coat
of approved steel primer using structural steel etc. as required.
In gratings, frames, guard bar, ladders, railings, brackets, gates
& similar works. Kg 85.95 0.00
55 Providing and fixing hand rail of approved size by welding etc.
to steel ladder railing, balcony railing, staircase railing and
similar works, including applying priming coat of approved
steel primer.
M.S. tube Kg 92.00 0.00
TOTAL- STEEL WORK 0.00
FLOORING/ DADO
56 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4
graded stone aggregate) finished with a floating coat of neat
cement, including cement slurry, but excluding the cost of
nosing of steps etc. complete.
40 mm thick with 20 mm nominal size stone aggregate
sqm 362.60 0.00
57 Chequerred precast cement concrete tiles 22 mm thick in
footpath & courtyard, jointed with neat cement slurry mixed
with pigment to match the shade of tiles, including rubbing
and cleaning etc. complete, on 20 mm thick bed of cement
mortar 1:4 (1 cement: 4 coarse sand).
Ordinary cement without any pigment
sqm 661.35 0.00
58 Kota stone slab flooring over 20 mm (average) thick base laid
over and jointed with grey cement slurry mixed with pigment
to match the shade of the slab, including rubbing and polishing
complete with base of cement mortar 1 : 4 (1 cement : 4 coarse
sand) :
25 mm thick sqm 1158.10 0.00
59 Kota stone slabs 20 mm thick in risers of steps, skirting, dado
and pillars laid on 12 mm (average) thick cement mortar 1:3
(1 cement: 3 coarse sand) and jointed with grey cement slurry
mixed with pigment to match the shade of the slabs, including
rubbing and polishing complete.
sqm 1238.20 0.00
60 Extra for pre finished nosing in treads of steps of Kota stone/
sand stone slab. RMT 84.85 0.00
61 Providing and fixing Ist quality ceramic glazed wall tiles
conforming to IS: 15622 (thickness to be specified by the
manufacturer), of approved make, in all colours, shades except
burgundy, bottle green, black of any size as approved by
Engineer-in-Charge, in skirting, risers of steps and dados, over
12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse
sand) and jointing with grey cement slurry @ 3.3kg per sqm,
including pointing in white cement mixed with pigment of
matching shade complete
Sqm 744.80 0.00
62 Providing and laying Ceramic glazed floor tiles of size 300x300
mm (thickness to be specified by the manufacturer) of 1st
quality conforming to IS : 15622 of approved make in colours
such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm
thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including
pointing the joints with white cement and matching pigment
etc., complete.
Sqm 688.35 0.00
63 Providing and laying vitrified floor tiles in different sizes
(thickness to be specified by the manufacturer) with water
absorption less than 0.08% and conforming to IS: 15622, of
approved make, in all colours and shades, laid on 20mm thick
cement mortar 1:4 (1 cement : 4 coarse sand), jointing with
grey cement slurry @ 3.3kg/sqm including grouting the joints
with white cement and matching pigments etc., complete.
Size of Tile 600x600 mm Sqm 1119.40 0.00
64 Providing and laying Vitrified tiles in different sizes (thickness
to be specified by manufacturer), with water absorption less
than 0.08 % and conforming to I.S. 15622, of approved make,
in all colours & shade, in skirting, riser of steps, over 12 mm
thick bed of cement mortar 1:3 (1
cement: 3 coarse sand), jointing with grey cement slurry @
3.3kg/sqm including grouting the joint with white cement &
matching pigments etc. complete.
Size of Tile 600x600 mm Sqmt 1135.20 0.00
65 Providing and laying ( 3.80mm- 4 mm thick) foam backed vinyl
floor covering (Abrasion GroupT) weighing 2975g/m2 in 2.0m
wide sheet form and providing high sound insulation (19dB).
The 0.65mm transparent wearlayer shall be treated with
protecsol, a UV cured, anti-glazing treatment with antistatic
properties (AS class 1) and should be treated with sanosol, an
antibacterial and fungicidal treatment. The rate shall include
cost of self levelling compound below flooring.
Sqm 0.00
66 Providing and laying ( 6mm- 8 mm thick) foam backed vinyl
floor covering (Abrasion GroupT) weighing 2975g/m2 in 2.0m
wide sheet form and providing high sound insulation (19dB).
The 0.65mm transparent wearlayer shall be treated with
protecsol, a UV cured, anti-glazing treatment with antistatic
properties (AS class 1) and should be treated with sanosol, an
antibacterial and fungicidal treatment. The rate shall include
cost of self levelling compound below flooring.
Sqm 0.00
Providing and laying C.C. pavement of mix M-25 with ready mixed
concrete from batching plant. The ready mixed concrete shall be
laid and finished with screed board vibrator , vacuum dewatering
process and finally finished by floating, brooming with wire brush
etc. complete as per specifications and directions of Engineer-
66-B incharge. (The panel shuttering work shall beaid for separately).
Cum 6848.85 0.00
TOTAL FLOORING/ DADO 0.00
FINISHING
Cement Plaster (in coarse sand)
67 12 mm cement plaster of mix :
1:4 (1 cement: 4 coarse sand) Sqm 180.85 0.00
68 15 mm cement plaster on rough side of single or half
brick wall of mix:
1:4 (1 cement: 4 coarse sand) Sqm 209.65 0.00
69 Extra for plastering exterior walls of height more than 10 m
from
ground level for every additional height of 3 m or part thereof.
10M TO 13M Sqm 40.65 0.00
13M TO 16M Sqm 81.30 0.00
16M TO 19M Sqm 121.95 0.00
70 Providing and applying white cement based putty of average
thickness 1 mm, of approved brand and manufacturer, over
the plastered wall surface
to prepare the surface even and smooth complete.
Sqm 87.35 0.00
71 Wall painting with premium acrylic emulsion paint of interior
grade, having VOC (Volatile Organic Compound ) content less
than 50 grams/ litre of approved brand and manufacture,
including applying additional coats wherever required to
achieve even shade and colour.
Two coats over water thinnable cement primer on wall
surface having VOC content less than 50 grams/litre Sqm 71.00 0.00
72 Applying priming coats with primer of approved brand and
manufacture, having low VOC (Volatile Organic Compound )
content.
With water thinnable cement primer on wall surface having
VOC content less than 50 grams/litre Sqm 36.95 0.00
73 Painting with synthetic enamel paint, having VOC (Volatile
Organic Compound) content less than 150 grams/ litre, of
approved brand and manufacture, including applying
additional coats wherever required to achieve even shade and
colour.
Two coats Sqm 75.00 0.00
74 Applying priming coats with primer of approved brand and
manufacture, having low VOC (Volatile Organic Compound )
content.
With ready mixed red oxide zinc chromatic on steel / iron
works having VOC content less than 250 grams/ litre Sqm 32.55 0.00
GI Metal Ceiling Lay in perforated Tegular edge global white
color tiles of size 595x595 mm and 0.5 mm thick with 8 mm
drop; made of GI sheet having galvanizing of 100 gms/sqm
(both sides inclusive) and 20% perforation area with 1.8 mm
dia holes and having NRC (Noise Reduction Coefficient ) of 0.5,
75 electro statically polyester powder coated of thickness 60 Sqm 1163.90 0.00
microns (minimum), including factory painted after bending
and perforation, and backed with a black Glass fiber acoustical
fleece.
TOTAL FINISHING 0.00
ALUMINUM WORKS as/Aluminum Annexure
76 Providing and fixing aluminium work for doors, windows,
ventilators and partitions with extruded built up standard
tubular sections/ appropriate Z sections and other sections of
approved make conforming to IS: 733 and IS: 1285, fixing with
dash fasteners of required dia and size, including necessary
filling up the gaps at junctions, i.e. at top, bottom and sides
with required EPDM rubber/ neoprene gasket etc. Aluminium
sections shall be smooth, rust free, straight, mitred and jointed
mechanically wherever required including cleat angle,
Aluminium snap beading for glazing / paneling, C.P. brass /
stainless steel screws, all complete as per architectural
drawings and the directions of Engineer-in-charge. (Glazing,
paneling and dash fasteners to be paid for separately) :
For fixed portion
Polyester powder coated aluminium (minimum thickness of
polyester powder coating 50 micron) Kg 391.80 0.00
77 For shutters of doors, windows & ventilators including
providing and fixing hinges/ pivots and making provision for
fixing of fittings wherever required including the cost of EPDM
rubber / neoprene gasket required (Fittings shall be paid for
separately).
Polyester powder coated aluminium (minimum thickness of
polyester powder coating 50 micron) Kg 452.40 0.00
78 Providing and fixing 12mm thick prelaminated particle board
flat pressed three layer or graded wood particle board
conforming to IS: 12823 Grade l Type ll, in panelling fixed in
aluminum doors, windows shutters and partition frames with
C.P. brass / stainless steel screws etc. complete as per
architectural drawings and directions of Engineer - in - Charge.
Pre-laminated particle board with decorative lamination on
both sides Sqm 866.60 0.00
79 Providing and fixing glazing in aluminium door, window,
ventilator shutters and partitions etc. with EPDM rubber/
neoprene gasket etc. complete as per the architectural
drawings and the directions of engineer-incharge.(Cost of
aluminium snap beading shall be paid in basic item)
With float glass panes of 5.50 mm thickness Sqm 1003.95 0.00
80 Filling the gap in between aluminium frame & adjacent RCC/
Brick/ Stone work by providing weather silicon sealant over
backer rod of approved quality as per architectural drawings
and direction of Engineer-in-charge complete.
Upto 5mm depth and 5 mm width Metre 62.45 0.00
81 Providing and fixing Fly proof stainless steel grade 304 wire
gauge with 0.5 mm dia. wire and 1.4 mm wide aperture in
aluminium door, window, ventilator shutters and partitions
etc. with EPDM rubber / neoprene gasket etc. complete as per
the architectural drawings and the directions of engineer-in-
charge .
sqm 1041.55 0.00
82 Providing and fixing M.S. grills of required pattern in frames of
windows etc. with M.S. flats, square or round bars etc.
including priming coat with approved steel primer all
complete.
Fixed to openings /wooden frames with rawl plugs screws etc.
Kg 112.45 0.00
83 Providing and fixing stainless steel ( Grade 304) railing made
of Hollow tubes, channels, plates etc., including welding,
grinding, buffing, polishing and making curvature (wherever
required) and fitting the same with necessary stainless steel
nuts and bolts complete, i/c fixing the railing
with necessary accessories & stainless steel dash fasteners ,
stainless steel bolts etc., of required size, on the top of the floor
or the side of waist slab with suitable arrangement as per
approval of Engineer-in-charge, (for payment purpose only
weight of stainless steel members shall be considered
excluding fixing accessories such as nuts, bolts, fasteners
etc.).
Kg 472.40 0.00
TOTAL -ALUMINUM WORKS 0.00
WATER PROOFING
84 Providing and Laying of foam concreate in sunkun portion
such as toilets kitchen etc. Cum
85 Providing and laying integral cement based treatment for
water proofing on horizontal surface at all depth below ground
level for under ground structures as directed by Engineer-in-
Charge and consisting of : i) Ist layer of 22 mm to 25 mm thick
approved and specified rough stone slab over a 25 mm thick
base of cement mortar 1:3 (1 cement : 3 coarse sand) mixed
with water proofing compound conforming to IS:2645 in the
recommended proportion over the leveling course (leveling
course to be paid separately). Joints sealed and grouted with
cement slurry mixed with water proofing compound. ii) 2nd
layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse
sand) mixed with water proofing compound in recommended
proportions. iii) Finishing top with stone aggregate of 10 mm
to 12 mm nominal size spreading @ 8 cudm/sqm thoroughly
embedded in the 2nd layer
Using rough kota stone. sqm 1017.55 0.00
86 Providing and laying integral cement based treatment for
water proofing on the vertical surface by fixing specified stone
slab 22 mm to 25 mm thick with cement slurry mixed with
water proofing compound conforming to IS:2645 in
recommended proportions with a gap of 20 mm (minimum)
between stone slabs and the receiving
surfaces and filling the gaps with neat cement slurry mixed
with water proofing compound and finishing the exterior of
stone slab with cement mortar 1:3 (1 cement : 3 coarse sand)
20 mm thick with neat cement punning mixed with water
proofing compound in recommended proportion complete at
all levels and as directed by Engineer-in-charge
Using rough Kota stone sqm 1253.30 0.00
87 Providing and laying water proofing treatment in sunken
portion of WCs, bathroom etc., by applying cement slurry
mixed with water proofing cement compound consisting of
applying : a) First layer of slurry of cement @ 0.488 kg/sqm
mixed with water proofing cement compound @ 0.253
kg/sqm. This layer will be allowed to air cure for 4 hours. b)
Second layer of slurry of cement @ 0.242 kg/sqm mixed with
water proofing cement compound @ 0.126 kg/sqm. This layer
will be allowed to air cure for 4 hours followed with water
curing for 48 hours. The rate includes preparation of surface,
treatment and sealing of all joints, corners, junctions of pipes
and masonry with polymer mixed slurry.
sqm 298.30 0.00
88 Providing and laying integral cement based water proofing
treatment including preparation of surface as required for
treatment of roofs, balconies, terraces etc consisting of
following operations: a) Applying a slurry coat of neat cement
using 2.75 kg/sqm of cement admixed with water proofing
compound conforming to IS. 2645 and approved by Engineer-
in-charge over the RCC slab including adjoining wallsupto 300
mm height including cleaning the surface before treatment.
b) Laying brick bats with mortar using broken bricks/brick
bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1
cement : 5 coarse sand) admixed with water proofing
compound conforming to IS : 2645 and approved by Engineer-
in-charge over 20 mm thick layer of cement mortar of mix 1:5
(1 cement :5 coarse sand ) admixed with water proofing
compound conforming to IS : 2645 and approved by Engineer-
in-charge to required slope and treating similarly the adjoining
walls upto 300 mm height including rounding of junctions of
walls and slabs
c) After two days of proper curing applying a second coat of
cement slurry using 2.75 kg/ sqm of cement admixed with
water proofing compound conforming to IS : 2645 and
approved by Engineer-in-charge. d) Finishing the surface with
20 mm thick jointless cement mortar of mix 1:4 (1 cement :4
coarse sand) admixed with water proofing compound
conforming to IS : 2645 and approved by Engineer-in-charge
including laying glass fibre cloth of approved quality in top
layer of plaster and finally finishing the surface with trowel
with neat cement slurry and making pattern of 300x300 mm
square 3 mm deep. e) The whole terrace so finished shall be
flooded with water for a minimum period of two weeks for
curing and for final test. All above operations to be done in
order and as directed and specified by the Engineer-in-Charge
With average thickness of 120mm and minimum thickness at
khurra as 65 mm. Sqm 1034.65 0.00
89 Providing & Applying high quality acrylic modified resin based
texture of Dholpur/Red sand stone Pattern with anti algae
and UV resistance properties to be applied as intermediate
finish in desired pattern @ 43.04 kgs/10 sqm to form film of 1-
1.5 mm thickness after scrapping and properly cleaning the
surface to remove loose particles from the plaster surface,
followed by top coating with Premium Acrylic Smooth exterior
paint with Silicone additives of required shade by two or
more coats @ 1.43 litres/10 sqm, complete as the direction of
Engineer -in-Charge.
Sqm 391.80 0.00
TOTAL- WATER PROOFING 0.00