0% found this document useful (0 votes)
603 views22 pages

K11450 - K11459 Operation Manual

This document provides operation instructions for the K1145X 4-Unit Reid Vapor Pressure Bath manufactured by Koehler Instrument Company. It includes specifications for the instrument, safety warnings, assembly and setup instructions, descriptions of instrument controls and temperature controller operation, and compliance with standards such as ASTM and WEEE Directive for proper end-of-life recycling. The certificate verifies that the K1145X was manufactured and tested in conformance with specifications for Reid Vapor Pressure testing.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
603 views22 pages

K11450 - K11459 Operation Manual

This document provides operation instructions for the K1145X 4-Unit Reid Vapor Pressure Bath manufactured by Koehler Instrument Company. It includes specifications for the instrument, safety warnings, assembly and setup instructions, descriptions of instrument controls and temperature controller operation, and compliance with standards such as ASTM and WEEE Directive for proper end-of-life recycling. The certificate verifies that the K1145X was manufactured and tested in conformance with specifications for Reid Vapor Pressure testing.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 22

K1145X

4-Unit Reid Vapor Pressure Bath

Operation and Instruction Manual

REV D

Koehler Instrument Company, Inc.


1595 Sycamore Avenue • Bohemia, New York 11716-1796 • USA
Toll Free: 1-800-878-9070 (US only) • Tel: +1 631 589 3800 • Fax: +1 631 589 3815
http://www.koehlerinstrument.com • e-mail: info@koehlerinstrument.com
Petroleum Testing & Analysis Instrumentation • Custom Design & Manufacturing
CERTIFICATE OF CONFORMANCE

Reid Vapor Pressure Bath


K1145X

This certificate verifies that part number K1145X, Reid Vapor Pressure Bath, was
manufactured in conformance with the applicable standards set forth in this
certification.

Specifications: ASTM D323


ASTM D1267
IP 69
IP 161
ISO 3007
ISO 4256
DIN 51616
DIN 51754
FTM 791-1201
NF M 07-007
NF M 41-010

This unit is tested before it leaves the factory, to ensure total functionality and
compliance to the above specifications and ASTM standards. Test and inspection
records are on file for verification.

Jesse Kelly
Application Engineer
Koehler Instrument Company
WEEE Directive Compliance Statement

Background
The goal of the WEEE Directive is to encourage design of environment-friendly products that increase reuse,
recycling and other forms of recovery to reduce waste streams and applies to listed Electronic and Electrical
Equipment (EEE) and Koehler's equipment falls broadly into Appendix 1A; Section 9 Monitoring and Control
Equipment: Measuring, weighing or adjusting appliances for household or as laboratory equipment.

Any associated non-embedded equipment such as Lighting (Saybolt Color) and PCs/Printers also fall under
WEEE. If provided with an order these ancillary items must be WEEE compliant. For these and other reasons
(printer cartridges are regionalized) the equipment must be supplied through a third party supplier in Europe.

The WEEE Directive applies to electrical and electronic equipment falling under the categories set out in Annex
IA provided that the equipment concerned is not part of another type of equipment that does not fall within the
scope of this Directive. Annex IB contains a list of products which fall under the categories set out in Annex IA.

http://eur-lex.europa.eu/LexUriServ/LexUriServ.do?uri=OJ:L:2003:037:0024:0038:en:PDF

We do not qualify for any of the 10 exemption categories.


http://www.dpa-system.dk/en/WEEE/Products/Exemptions

Professional use
For equipment defined for ’professional use’ local authorities have no role to play. Producers and importers are
basically responsible for collection of WEEE recyclables from the professional user and for subsequent
management. A separate statement is given cataloging the items that require separation from the equipment
along with basic information on subsequent processing or recycling prior to disposal of the equipment.
http://www.dpa-system.dk/en/WEEE/Products/Private-or-professional-use

Responsibility for Registration and Annual Reporting:


Koehler will not sell directly to end users in the EU and so has no responsibility to register within each EU state
and to make annual reports. Koehler declares that this responsibility is born by the importer who is the first
level of the distribution chain and is subject to producer responsibility. We will communicate this in writing to
our distributor/importers in the EU stating they are responsible to satisfy WEEE registration and reporting
requirements in the EU states where they conduct sales activities.

It is illegal to market electrical and electronic equipment covered by producer responsibility without being
registered.

http://www.dpa-system.dk/en/WEEE/Producers/Whoissubjecttoproducerresponsibility

Product Design
Koehler's designs allow for complete disassembly to a modular level which usually allows for standard
recycling. A qualified refrigeration system technician must be consulted when disassembling and de-
commissioning any equipment with refrigeration systems.

Koehler's scientific testing equipment is robustly designed to function over a long service life and are typically
repaired many times over the course of years rather than being replaced. We believe that re-use and
refurbishment is the very best form of re-cycling.

All batteries must be readily removable not soldered in place.

Recycling instructions
In the event that replacement becomes necessary, we will include instructions, particularized to each
instrument that informs the customer of their recycling responsibilities and giving them guidance in doing this.
All Koehler equipment has been placed on the market since 13th August 2005 and so Koehler is defined as a
"new WEEE producer". As such we must provide information on refurbishment, treatment, and re-use.

Our instrument manual will include this compliance statement and indicate that any collection of materials will
be handled by their authorized distributor. In the event that the distributor is unreachable or is no longer a
distributor for Koehler Instrument, Co., other arrangements may be made including accepting the materials
directly.

Recycling is free of charge. Shipping is the responsibility of the end users. Whether shipping to a distributor or
to Koehler directly, safe, properly declared, and labeled packaging and shipping expenses are the sole
responsibility of the end user.

WEEE Marking

Since Koehler products are subject to the WEEE Directive we must display the WEEE symbol shown above in
accordance with European Standard EN 50419 on the equipment. It must be indelible, at least 5mm in height,
and clearly legible. If the equipment is too small the mark must be in the product literature, guarantee
certificate, or on the packaging. Rules on marking are established in section 49 of the WEEE Order.

Koehler Instrument Company, Inc.


c/o RECYCLING
1595 Sycamore, Ave.
Bohemia, NY 11716

As a minimum the following substances, preparations and components have to be removed from any
separately collected WEEE:
- Mercury containing components, such as switches or backlighting lamps (compact fluorescent lamps, CFL),
- Batteries
- Printed circuit boards if the surface of the printed circuit board is greater than 10 square centimeters (about 4
sq in.),
- Toner cartridges, liquid and pasty, as well as color toner,
- Chlorofluorocarbons (CFC), hydrochlorofluorocarbons (HCFC) or hydrofluorocarbons (HFC), hydrocarbons
(HC)
- Liquid crystal displays (together with their casing where appropriate) of a surface greater than 100 square
centimeters and all those back-lighted with gas discharge lamps,
- External electric cables
- Components containing refractory ceramic fibers as described in Commission Directive 97/69/EC of 5
December 1997 adapting to technical progress Council Directive 67/548/EEC relating to the classification,
packaging and labeling of dangerous substances (2),
- Electrolyte capacitors containing substances of concern (height > 25 mm, diameter > 25 mm or
proportionately similar volume)

2. The following components of WEEE that is separately collected have to be treated as indicated:
- Equipment containing gases that are ozone depleting or have a global warming potential (GWP) above 15,
such as those contained in foams and refrigeration circuits: the gases must be properly extracted and properly
treated. Ozone-depleting gases must be treated in accordance with Regulation (EC) No 2037/2000 of the
European Parliament and of the Council of 29 June 2000 on substances that deplete the ozone layer (4).
K1145X 4-Unit Reid Vapor Pressure Bath
Operation and Instruction Manual

Table of Contents

1 Introduction .........................................................................................2
1.1 Koehler’s Commitment to our Customers .............................................................. 2
1.2 Recommended Publications .................................................................................. 2
1.3 Instrument Specifications ....................................................................................... 3
2 Safety Information and Warnings ......................................................3
3 Getting Started ....................................................................................3
3.1 Packing List ............................................................................................................ 3
3.2 Unpacking .............................................................................................................. 3
3.3 Assembly ................................................................................................................ 4
3.4 Accessories for Test............................................................................................... 4
4 Descriptions ........................................................................................5
4.1 Instrument Controls ................................................................................................ 5
4.2 Temperature Controller Operation ......................................................................... 6
5 Operation .............................................................................................6
5.1 Bath ........................................................................................................................ 7
5.2 Power ..................................................................................................................... 7
5.3 Cylinders ................................................................................................................ 8
6 Maintenance ........................................................................................8
6.1 Routine Maintenance ............................................................................................. 8
6.2 Replacement Parts................................................................................................. 8
7 Wiring Diagrams..................................................................................9
7.1 K11450 (115V Unit)................................................................................................ 9
7.2 K11459 (220V Unit).............................................................................................. 10
8 Service ...............................................................................................11
9 Storage ...............................................................................................11
10 Warranty.............................................................................................11
11 Returned Goods Policy.....................................................................11
Notes .......................................................................................................12

K1145X-Manual
-1-
K1145X 4-Unit Reid Vapor Pressure Bath
Operation and Instruction Manual

http://www.astm.org
1 Introduction email: service@astm.org
The Koehler K1145X 4 Unit Reid Vapor
Pressure Bath is the latest design for performing ASTM Publication:
constant temperature Reid Vapor Pressure  ASTM D323: Vapor Pressure of
determinations of liquid petroleum products and Petroleum Products (Reid Method)
liquefied petroleum gases (LPG).  ASTM D4693: Vapor Pressure of LP
Gases
This manual provides important information
regarding safety, technical reference, installation 2. Energy Institute (IP)
requirements, operating condition specifications, 61 New Cavendish Street
user facility resource requirements, and operating London, WIM 8AR, United Kingdom
instructions for the Reid Vapor Pressure Tel: 44 (0)20 7467 7100
apparatus. This manual should also be used in Fax: 44 (0)20 7255 1472
conjunction with applicable published laboratory http://www.energyinstpubs.org.uk/
procedures. Information on these procedures is
given in section 1.2. IP Publication:
 IP 69
1.1 Koehler’s Commitment to our  IP 161
Customers
3. International Organization for Standardization
Providing quality testing instrumentation and
(ISO)
technical support services for research and testing
1, rue de Varembé
laboratories has been our specialty for more than
Case postale 56
50 years. At Koehler, the primary focus of our
CH-1211 Geneva 20, Switzerland
business is providing you with the full support of
Tel: 41 22 749 01 11
your laboratory testing needs. Our products are
Fax: 41 22 733 34 30
backed by our staff of technically knowledgeable,
http://www.iso.org
trained specialists who are experienced in both
petroleum products testing and instrument service
ISO Publication:
to better understand your requirements and
 ISO 3007
provide you with the best solutions. You can
depend on Koehler for a full range of accurate and  ISO 4256
reliable instrumentation as well as support for your
laboratory testing programs. Please do not 4. Deutsche International Norm (DIN)
hesitate to contact us at any time with your http://www.din.de
inquiries about equipment, tests, or technical
support. DIN Publication:
 DIN 51616
 DIN 51754
Toll Free: 1-800-878-9070 (US only)
Tel: +1 631 589 3800 5. Federal Test Method (FTM)
Fax: +1 631 589 3815
FTM Publication:
Email: info@koehlerinstrument.com  FTM 791-1201
http://www.koehlerinstrument.com
6. GPA

1.2 Recommended Publications GPA Publication:


1. American Society for Testing and Materials  GPA 2140
(ASTM)
100 Barr Harbor Drive
West Conshohocken, Pennsylvania 19428-
2959, USA
Tel: +1 610 832 9500
Fax: +1 610 832 9555

K1145X-Manual
-2-
K1145X 4-Unit Reid Vapor Pressure Bath
Operation and Instruction Manual

1.3 Instrument Specifications point or the maximum recommended temperature


range. The power can only then be restored by
Models: K11450 identifying and correcting the problem, allowing
K11459 the unit to return to normal operating
temperatures, and resetting the power to the unit.
Electrical
Requirements: 115V 60Hz Unit Design. This equipment is specifically
220-240V 50/60Hz designed for use in accordance with the applicable
standard test methods listed in section 1.2 of this
Capacity: Four (4) Vapor Pressure manual. The use of this equipment in accordance
Apparatus, one-or two- with any other test procedures, or for any other
opening type purpose, is not recommended and may be
extremely hazardous.
Maximum
Temperature: 212°F (100°C) Chemical Reagents Information. Chemicals and
reagents used in performing the test may exhibit
Temperature potential hazards. Any user must be familiarized
Control Stability: ±0.2°F (±0.1°C) with the possible dangers before use. We also
recommend consulting the Material Data and
Bath Capacity: 13.7 gal (51.9L) water Safety Sheet (MSDS) on each chemical reagent
for additional information. MSDS information can
Dimensions be easily located on the internet at
(l x w x h): 15 x 15 x 36 in http://siri.uvm.edu or http://www.sigma-
(38.1 x 38.1 x 91.5 cm) aldrich.com.
Net Weight: 67 lbs (30.4 kg)
3 Getting Started
The instructions for preparing the equipment
2 Safety Information and Warnings assume that the user is aware of the contents of
this document, which lists the warranty conditions
Safety Considerations. The use of this and important precautions.
equipment may involve hazardous materials and
operations. This manual does not purport to
3.1 Packing List
address all of the safety problems associated with
the use of this equipment. It is the responsibility of  K1145X 4-Unit Reid Vapor Pressure Bath
any user of this equipment to investigate,  K70519 RTD Temperature Probe
research, and establish appropriate safety and Assembly
health practices and determine the applicability of  K1145X-Manual 4-Unit Reid Vapor
regulatory limitations prior to use. Pressure Bath Operation and Instruction
Manual
Equipment Modifications and Replacement
Parts. Any modification or alteration of this Accessories (purchased separately, see Section
equipment from that of factory specifications is not 3.4 for more information):
recommended voids the manufacturer warranty,
product safety, performance specifications, and/or  K11500 Reid Vapor Pressure Cylinder,
certifications whether specified or implied, and One-Opening Type
may result in personal injury and/or property loss.  K11201 Reid Vapor Pressure Cylinder,
Replacement parts must be O.E.M. exact Two-Opening Type
replacement equipment.  311-Series Reid Vapor Pressure Gauges
Over Temperature Protection. This unit is
3.2 Unpacking
equipped with Over Temperature Protection (OTP)
circuitry to prevent overheating. The unit will 1. Carefully remove the wooden crate from
automatically interrupt power whether equipment around the unit and place the bath on a firm
malfunction or operator error causes the level surface free from excessive drafts, where
temperature to exceed either 20 °C above the set there are no corrosive fumes, excessive

K1145X-Manual
-3-
K1145X 4-Unit Reid Vapor Pressure Bath
Operation and Instruction Manual

moisture, high room temperature, or excessive  Clearance from other instruments


dust.
 Temperature Range: 5 to 40°C
 Elevation to 2000 meters
WARNING: Be sure two or more individuals  Relative Humidity: < 80%
are available for extracting and lifting instrument
from box to cart and from cart to bench. Temperature Probe: The RTD Thermocouple
Individuals must lift in accordance to proper probe is shipped in a separate bag within the bath.
technique. See Figure below. Remove the thermocouple from the bag and insert
it in the thermocouple port. Insert the RTD
connector into the receptacle located on the rear
of the bath (see Section 4.1)

3.4 Accessories for Test


Reid Vapor Pressure Cylinders

Koehler offers both one-


2. Lift instrument from cart and place on bench. opening and two-opening
type Reid Vapor Pressure
3. Ensure that all parts listed on the packing list Cylinders for vapor pressure
are present. Inspect the unit and all tests of liquid petroleum
accessories for damage. If any damage is products, volatile crude oil,
found, keep all packing materials and and liquefied petroleum gas
immediately report the damage to the carrier. (LPG). The cylinders
We will assist you with your claim, if consists of upper and lower
requested. When submitting a claim for chambers in the required 4:1
shipping damage, request that the carrier volume ratio, and O-ring
inspect the shipping container and equipment. gaskets provide tight seal
Do not return goods to Koehler without written between chambers and at
authorization. gauge coupling. One-opening type is for gasoline
and other products having a Reid Vapor Pressure
below 26psa. Two opening type is for liquid
3.3 Assembly
products having a Reid Vapor Pressure above 26
psi and for LPG. For LPG testing, the two-opening
WARNING: Do NOT power on the bath type apparatus is used with an additional bleeder
without filling with water. See Section 5.1. valve assembly.
Part No. Description
Equipment Placement: Place the instrument on a
firm, level table in an area with adequate K11500 Reid Vapor Pressure Cylinder, One-
ventilation or in a hood. The unit may be leveled Opening Type
by making minor turning adjustments to the feet
K11201 Reid Vapor Pressure Cylinder, Two-
located at the base of the unit. Please note that Opening Type
Koehler does not supply a level with this
equipment. K11202 Bleeder Valve Assembly for LPG tests
(for K11201 Cylinder)
Environmental Conditions: The instrument
environment must comply with the following
conditions for proper setup:
 No / Low Dust
 No direct sunlight
 Not near heating or AC ventilation ducts
 No Vibrations

K1145X-Manual
-4-
K1145X 4-Unit Reid Vapor Pressure Bath
Operation and Instruction Manual

Reid Vapor Pressure Gauges 4 Descriptions


Figure Interval
Range 4.1 Instrument Controls
Part No. Intervals Graduations
psi/kPa
psi/pka psi/kPa
311-005-002 0-5 0.5psi 0.05 psi
311-015-002 0-15/0-100 1.0/10 0.1/1.0
311-030-002 0-30/0-200 5.0/20 0.5/2.0
311-060-002 0-60/400 5.0/50 0.2/2.5
311-100-002 0-100/700 10/50 0.5/2.5
311-250-001 0-250/1750 25/100 1.0/20
311-600-003 0-600/4200 50/250 2.0/25

Additional Accessories

Part No. Description


250-000-18F ASTM 18F Thermometer
Range: 94 to 108°F
250-000-18C ASTM 18C Thermometer
Range: 34 to 42°C
250-000-65F ASTM 65F Thermometer
Range: 122 to 176°F
250-000-65C ASTM 65C Thermometer
Range: 50 to 80°C
K11810 Transfer Connection

371-000-002 Mercury Manometer

K112B-1-0-12 Manometer Adapter

AS568-210 O-ring Seal, between air and gas


chambers
AS568-113 O-ring Seal, between gauge and 1. Thermometer Port. This port allows for
bleeder valves independent temperature measurement of the
bath temperature with a thermometer for
K40100 Flexible Tubing precise temperature measurements and digital
temperature controller calibration. If the
controller needs to be calibrated, then please
contact the Koehler technical service
department.

2. Thermocouple Port. This port allows for


temperature measurement of the bath
temperature with a Pt-100 RTD probe for
precise temperature measurement.

3. Cylinder Hooks. See section 5.3 for detail on


placing cylinders in hooks.

4. Motor Switch. Controls power to the motor for


the stirrer.

K1145X-Manual
-5-
K1145X 4-Unit Reid Vapor Pressure Bath
Operation and Instruction Manual

5. Temperature Controller. The temperature


controller regulates the bath temperature for 3. Programming Key. Permits scrolling
the test procedure. Refer to Section 4.2 for full through controller menu parameters. One
operational details. Level Forward

6. Power Switch. This switch controls the power 4. Down Key. Used to decrease the set
to the entire unit. point temperature and to decrease or
change parameter values when
programming the temperature controller.

5. Up Key. Used to increase the set point


temperature and to increase or change
parameter values when programming the
temperature controller.

6. Exit / Function Key. This key is used to


exit or leave a level. One level backward

IMPORTANT NOTE: The digital


temperature controller for the unit comes
pre-programmed from the Koehler factory.
Please do NOT attempt to re-program the
digital temperature controller as this will
void the product warranty. If assistance is
required, please do not hesitate to contact
the Koehler technical service department.
4.2 Temperature Controller Operation
Setting the Temperature. Set the desired
operating temperature by adjusting the set
point with the up and down keys. The set point
will be displayed in the lower green Set Point
LED display and the actual temperature will be
displayed in the upper red Process LED
display. Please allow the instrument to fully
equilibrate before proceeding with any testing.

Temperature Calibration. This routine allows the


digital temperature controller to be calibrated
to a certified thermometer.

a. Use a certified calibrated measuring


device to acquire the temperature.
Calculate the difference between the
measuring device and the Process value
displayed on the controller.
b. Press the program key two times until PCt
is displayed in the lower green LED
Figure 4. Temperature Controller display. Press the DOWN key. CAL will
display on the lower green display. If there
1. Process Temperature Display. The is a value observed in the upper red LED
upper red LED display shows the process display, add it to the calculated difference
temperature as read from the RTD probe. obtained in the previous step. This is the
offset value.
2. Set Point Temperature Display. The
lower green LED display shows the set c. Press the Program Key. The lower green
point temperature of the controller. display will flash. Use the up or down keys

K1145X-Manual
-6-
K1145X 4-Unit Reid Vapor Pressure Bath
Operation and Instruction Manual

to adjust to the new calibration offset


value on the upper red display calculated
WARNING: MAKE SURE THE FLUID
in the previous step. When the value has
RELEASE VALVE ON THE DRAIN LOCATED IN
been entered, the controller will
THE BACK OF THE UNIT (SEE BELOW) IS
automatically store the value. The lower
CLOSED BEFORE FILLING WITH WATER.
green display will stop flashing. If further
adjustments are necessary, press the
Program Key again. Resume regular
operations by pressing the Exit / Function
key two times. Verify if the new calibration
is correct by observing the upper red
display and comparing the value with the
calibrated reference device.

Auto Tune. This routine allows the digital


temperature control to learn the heating
parameters needed for any particular set point
temperature. This operation should be done
when installing a new unit, after replacing or
changing the bath medium type, or utilizing a
different temperature set point 20% different
from the previously used set point
temperature.

a. Set the operating temperature to the


desired setting.

b. Press the up and down arrow buttons


simultaneously for about 5 seconds. When
Auto Tune is active, the lower green LED
display will blink TUNE. Auto Tune will The overflow outlet will drain water if the liquid
automatically toggle off when the set point level reaches too high. This ensures the water
temperature is reached. Auto tune can be does not overflow over the top of the bath.
terminated by pressing the up & down
buttons simultaneously again. 5.2 Power

5 Operation 1. Connect the line cord to a properly fused and


grounded receptacle with the correct voltage
as indicated in section 1.3 or on the back of
For detailed preparation and operation the unit.
instructions, refer to:

ASTM D323 DIN51616


ASTM D1267 DIN51754 WARNING: Do NOT turn the power on
IP69 FTM 791-1201 unless the bath is filled with the proper medium;
IP161 GPA 2140 otherwise, damage may occur to the unit and the
ISO3009 ISO4256 warranty would be void.

5.1 Bath 2. Power ON the unit by pushing the line switch.

Fill the bath with water at room temperature. Be 3. Power ON the stirrer by pushing the motor
careful not to fill past the overflow valve. switch.

K1145X-Manual
-7-
K1145X 4-Unit Reid Vapor Pressure Bath
Operation and Instruction Manual

5.3 Cylinders 6 Maintenance


Fully Assembled Cylinder (with Bleeder Valve)
WARNING. Disconnect power to the unit
before servicing to avoid exposure to high
1. RVP Gage voltages and/or temperatures which may result in
2. Gage Coupling personal injury or death. If you have any questions
3. Bleeder Valve about maintaining your equipment, then please do
4. Air Chamber not hesitate to contact the Koehler technical
5. Transfer Valve service department.
6. Liquid Chamber
7. Fill Valve 6.1 Routine Maintenance
The K1145X 4-Unit Reid Vapor Pressure Bath
requires little routine maintenance to provide many
years of continuous service. However, over the
course of time, some instrument parts may need
to be replaced. When ordering replacement
part(s), please provide the model number, serial
number, and product shipment date of your
Attach the bleeder valve by equipment so that we can ensure you will receive
removing the gage coupling the proper replacement part(s).
from the top of the cylinder and
screwing in the bleeder valve. 6.2 Replacement Parts
Re-attach the gage coupling to
the top of the bleeder valve, Part Number Description
and screw in the gage. If the
bleeder valve is not used, K11450-0-1 Heater, 2000W, 115V†
simply screw the gage into the K11459-0-1 Heater, 2000W, 230V‡
coupling at the top of the
cylinder. K70519 RTD Temperature Probe
Assembly
Engaging Cylinders in the Bath 275-103-044 Temp. Controller, 100-240V
50/60Hz 7A
Place the assembled cylinder, including the gage,
into the hooks in the bath as shown: 091-032-001 Solid State Relay, 20A,
4-32VDC
090-120-014 Relay, 120VAC, 10A, SPDT†
090-240-018 Relay, 240VAC, 10A, SPDT‡
271-025-004 Circuit Breaker, 25A, 2 Pole†
271-015-004 Circuit Breaker, 2 Pole, 15A‡
278-020-004 Time Delay Fuse, 20A, 600VAC
278-001-002 Fuse, 1A, Slo-Blo, 5x20mm
050-001-028 Switch, Single Pole, 15A
K23700-03013A Motor, 115V 60Hz, 1/20HP†
K23700-03014A Motor, 230V 60Hz, 1/15HP‡


For 115V model ONLY (K11450)

For 230V model ONLY (K11459)

K1145X-Manual
-8-
K1145X 4-Unit Reid Vapor Pressure Bath
Operation and Instruction Manual

7 Wiring Diagrams

7.1 K11450 (115V Unit)

K1145X-Manual
-9-
K1145X 4-Unit Reid Vapor Pressure Bath
Operation and Instruction Manual

7.2 K11459 (220V Unit)

K1145X-Manual
- 10 -
K1145X 4-Unit Reid Vapor Pressure Bath
Operation and Instruction Manual

8 Service EXPRESSED OR IMPLIED, INCLUDING ANY


IMPLIED WARRANTIES OF FITNESS FOR A
Under normal operating conditions and with PARTICULAR PURPOSE. Please save the
routine maintenance, the K1145X 4-Unit Reid shipping carton in the event the equipment needs
Vapor Pressure Bath should not require service. to be returned to the factory for warranty repair. If
Any service problem can be quickly resolved by the carton is discarded, it will be the purchaser’s
contacting Koehler’s technical service department responsibility to provide an appropriate shipping
either by letter, phone, fax, or email. In order to carton.
assure the fastest possible service, please provide
us with the following information. 11 Returned Goods Policy
Model Number: To return products for credit or replacement,
please contact Koehler Customer Service with
Serial Number: your purchase order number, our packing
Date of Shipment: list/invoice number, the item(s) to be returned and
the reason for the return. You will be issued a
Returned Authorization (RA) number, which must
9 Storage be prominently displayed on the shipping
container when you return the material to our
This laboratory test instrument is equipped with
plant. Shipping containers without an RA number
electrical components. Storage facilities should be
prominently displayed will be returned to the
consistent with an indoor laboratory environment.
sender. Goods must be returned freight prepaid.
This testing equipment should not be subjected to
Returns will be subject to a restocking charge, the
extremes of temperature and/or moisture.
application of which will depend upon the
circumstances necessitating the return. Some
This equipment was shipped from the factory in
returns cannot be authorized, including certain
a corrugated cardboard container. If long term
products purchased from outside vendors for the
storage is anticipated, re-packing the instrument in
convenience of the customer, products
a water-resistant container is recommended to
manufactured on special order, products shipped
ensure equipment safety and longevity.
from the factory past ninety (90) days, and
products which have been used or modified in
10 Warranty such a way that they cannot be returned to stock
for future sale.
We, at Koehler, would like to thank you for your
equipment purchase, which is protected by the
following warranty. If within one (1) year from the
date of receipt, but no longer than fifteen (15)
months from the date of shipment, Koehler
equipment fails to perform properly because of
defects in materials or workmanship, Koehler
Instrument Company, Inc. will repair or, at its sole
discretion, replace the equipment without charge
F.O.B. its plant, provided the equipment has been
properly installed, operated, and maintained.
Koehler Instrument Company must be advised in
writing of the malfunction and authorize the return
of the product to the factory. The sole
responsibility of Koehler Instrument Company and
the purchaser’s exclusive remedy for any claim
arising out of the purchase of any product is the
repair or replacement of the product. In no event
shall the cost of the purchaser’s remedy exceed
the purchase price, nor shall Koehler Instrument
Company be liable for any special, indirect,
incidental, consequential, or exemplary damages.
KOEHLER INSTRUMENT COMPANY, INC.
DISCLAIMS ALL OTHER WARRANTIES,

K1145X-Manual
- 11 -
K1145X 4-Unit Reid Vapor Pressure Bath
Operation and Instruction Manual

Notes

K1145X-Manual
- 12 -
K1145X 4-Unit Reid Vapor Pressure Bath
Operation and Instruction Manual

Notes

K1145X-Manual
- 13 -
K1145X 4-Unit Reid Vapor Pressure Bath
Operation and Instruction Manual

Notes

K1145X-Manual
- 14 -

You might also like